APPENDIX C - TEST EQUIPMENT REQUIREMENTS
1. GENERAL
Thi s Appendi x cont ai ns a l i st of t est equi pment sui t abl e f or per f or mi ng al l t est
pr ocedur es cont ai ned i n t hi s manual . Ot her equi pment meet i ng speci f i cat i ons l i st ed i n
t hi s Appendi x may be subst i t ut ed i n pl ace of r ecommended model s. Equi pment l i st ed i n
t hi s Appendi x may exceed mi ni mum r equi r ed speci f i cat i ons f or some pr ocedur es
cont ai ned i n t hi s manual .
2. RECOMMENDED TEST EQUIPMENT
TYPE MODEL SPECI FI CATI ONS
Dual Pul se Generat or WAVETEK 145
or Equi val ent
Funct i ons: Pul se
Pul se Del ay: 50 ns t o 10 ms
Pul se Wi dt h: 25 ns t o 1 ms
Out put Level : 15 VP- P i nt o 50
Frequency Count er HP53131A
or Equi val ent
Fr equency: 10 Hz t o 10 MHz
Resol ut i on: 0. 001 Hz
Sensi t i vi t y: 150 mV
Frequency St andard HP58503A
or Equi val ent
Accur acy: 1 X 10
- 9

Osci l l oscope TEK 2465
or Equi val ent
Capabi l i t y: Dual Tr ace
Bandwi dt h: dc t o 100 MHz
Ver t i cal
Accur acy: 10%
Ti me
Accur acy: 0. 7% of Ti me I nt er val
0. 6% of Ful l Scal e
Ti me
Accur acy: 0. 7% of Ti me I nt er val
0. 3% of Ful l Scal e
Power Met er HP437B
wi t h (HP8481A Sensor)
or Equi val ent
Range: - 25 t o - 15 dBm
Accur acy: 0. 05 dB
Spect rum Anal yzer HP8569B
or Equi val ent
Range: 10 kHz t o 2. 6 GHz
RBW: 300 Hz t o 3. 0 MHz
Di spl ay ( Log)
Accur acy: <0. 1 dB/ dB
<1. 5 dB/ 70 dB
Di spl ay ( Li n)
Accur acy: <3% of r ef er ence l evel
over 8 di vi si on r ef l ect i on