1 SUMMARY
Third Carrier Implementation: Modify existing S/2/2/2 configuration become to S/3/3/3 with
adding new WRFU board scenari o to keep the 40W /carrier after the activation.

RNC and Nodeb Hardware & Software Version :

Network Equipment Current Version
RNC BSC6900 UO UMTS V900R013ENGC00SPH552
NodeB BTS3900/BTS3900A/BTS3900L (Macro Site) WCDMA V200R013C00SPC339

Technical Implementation:
Site Hardware Reconfiguration and Installation ( Insert WBBP , WRFU, Interconnection cable
and CPRI cable connection)
Data Configuration


Site Hardware Installation:

Site Hardware
Qty
S333 Site
1 Add WRFU board 3
2 Add CPRI cabl e 3
3 Add WBBP 1














Nodeb Hardware Installation Overview:



2 Network impact for Third Carrier

NodeB service would be down about 70 minutes.
It only impacts one site service.

3 RNC SIDE CONFIGURATION
3..1 Obj ective
Third Carrier configuration at RNC side

Data Configuration NE Remark
1. Deactivate cell RNC RF
2. Add Ulocell RNC RF
3. Add USAC RNC RF
4. Add UCELLQUICKSETUP RNC RF
5. Activate cell RNC RF




3..2 Preparation Before Execution
Backup Existing Script

BKP DB:;
EXP CFGMML:;
3..3 Procedure and Work Flow
Step 1 Deactivate Cel l
DSP UCELL: DSPT=BYNODEB, NodeBName="xxx";
DEA UCELL: CellId=xxx;
DEA UCELL: CellId=xxx;
DEA UCELL: CellId=xxx;
DEA UCELL: CellId=xxx;
DEA UCELL: CellId=xxx;
DEA UCELL: CellId=xxx;

Noted : after deactivated ucell, subcon on site can directly change the j umper connection

Step 2 Add Ulocel l
ADD ULOCELL: NodeBName="abc", LoCell=xxx;
ADD ULOCELL: NodeBName="abc", LoCell=xxx;
ADD ULOCELL: NodeBName="abc", LoCell=xxx;


Step 3 Add USAC
ADD USAC: CnOpIndex=0, LAC=xxx, SAC=xxx;
ADD USAC: CnOpIndex=0, LAC=xxx, SAC=xxx;
ADD USAC: CnOpIndex=0, LAC=xxx, SAC=xxx;


Step 4 Add UCELLQUICKSETUP
(noted: Third Carrier used thi s frequency for ULFREQ=9788, DLFREQ=10738, SpgID used 2, all data
provided at CDR)

ADD UCELLQUICKSETUP: CellId=xxx, CellName="ABC", PeerIsValid=INVALID, CnOpGrpIndex=0,
BandInd=Band1, UARFCNUplink=9788, UARFCNDownlink=10738, PScrambCode=xxx, Tcell=CHIP0,
LAC=xxx, SAC=xxx, CfgRacInd=REQUIRE, RAC=xxx, SpgId=2, URANUM=D1, URA1=xxx,
NodeBName="ABC", LoCell=xxx, MaxTxPower=xxx, PCPICHPower=xxx;






Step 5 Add UCELLHSDPA
// HSPA + 21Mbps

ADD UCELLHSDPA: CellId=xxx, AllocCodeMode=Automatic, CodeAdjForHsdpaSwitch=ON,
CodeAdjForHsdpaUserNumThd=3;

MOD UCELLALGOSWITCH: CellId=xxx, NBMCacAlgoSwitch=CRD_ADCTRL-1&HSDPA_UU_ADCTRL-1,
NBMLdcAlgoSwitch=UL_UU_LDR-1&DL_UU_LDR-1&CELL_CODE_LDR-1&CELL_CREDIT_LDR-1,
HspaPlusSwitch=64QAM-1&DL_L2ENHANCED-1;

Step 6 Add UCELLHSUPA
// HSUPA 5.7Mbps

ADD UCELLHSUPA:CELLID=xxx, EAGCHCODENUM=1, ERGCHEHICHCODENUM=1,
MAXTARGETULLOADFACTOR=75, NONSERVTOTOTALEDCHPWRRATIO=0;

4 NODEB SIDE Hardware & Configuration implementation
4..1 Obj ective
Third Carrier configuration at Nodeb side and installation nodeb hardware

Nodeb Hardware Installation Scenario :

Macro Si te Scenario





































4..2 Preparation Before Execution
Backup Existing Script

Nodeb.xml

Check Existing Nodeb Alarm

LST ALMAF

4..3 Procedure and Work Flow

Step 1 Add WBBP Board i f only one
DSP BRD:;
ADD BRD: SN=2, BT=WBBP;

Step 2 List and add RRU , RRU Chai n based on topol ogy above
(Noted: add RRU and RRUchain make sure check cpri cable which is connected from WRFU to WBBP,
usually new board used wrfu board at slot 1, 3, 5 and wbbp board slot 2)
LST RRU:;
LST RRUCHAIN:;
ADD RRU: CN=0, SRN=xxx, SN=xxx, TP=TRUNK, RCN=xxx, PS=0, RT=WRFU, RS=UO, ALMPROCSW=ON;
ADD RRU: CN=0, SRN=xxx, SN=xxx, TP=TRUNK, RCN=xxx, PS=0, RT=WRFU, RS=UO, ALMPROCSW=ON;


ADD RRU: CN=0, SRN=xxx, SN=xxx, TP=TRUNK, RCN=xxx, PS=0, RT=WRFU, RS=UO, ALMPROCSW=ON;

ADD RRUCHAIN: RCN=xxx, TT=CHAIN, BM=COLD, HSN=2, HPN=0;
ADD RRUCHAIN: RCN=xxx, TT=CHAIN, BM=COLD, HSN=2, HPN=0;
ADD RRUCHAIN: RCN=xxx, TT=CHAIN, BM=COLD, HSN=2, HPN=0;

HSN (Head Sl ot No): only can configured at sl ot 2 and 3 only

Step 3 List and Add ULgroup/DLgroup and WBBP board based on topology above
(Noted: Third Carrier usually used DLgoup and ULgroup no 1 & WBBP board at slot 2, before add this
board make sure there are cpri cable connected to WRFU board for wbbp board allocation)

LST DLGROUP: DLGROUPN=xxx;
LST ULGROUP: ULGROUPN=xxx;
RMV DLGROUP: DLGROUPN=0;
RMV ULGROUP: ULGROUPN=0;


ADD ULGROUP: ULGROUPN=0, DEMMODE=DEM_2_CHAN, SNE1=3;
ADD DLGROUP: DLGROUPN=0, SNE1=3;

ADD ULGROUP: ULGROUPN=1, DEMMODE=DEM_2_CHAN, SNE1=2;
ADD DLGROUP: DLGROUPN=1, SNE1=2;

Step 4 Modi fy RX mode (Reconfigure XL Axi ata RX mode)
(Noted: Before Modify list first and backup all information as attached below)

Lst Locell and Sector
nodeb ran sharing.txt

// Remove XL Cell to Configure antenna Sector

LST LOCELL: MODE=LOCALCELL, LOCELL=xxx
RMV LOCELL:LOCELL=1;
RMV LOCELL:LOCELL=2;
RMV LOCELL:LOCELL=3;
RMV LOCELL:LOCELL=4;
RMV LOCELL:LOCELL=5;
RMV LOCELL:LOCELL=6;

LST SEC: STN=xxx, SECN=xxx


RMV SEC: STN=xxx, SECN=0;
RMV SEC: STN=xxx, SECN=1;
RMV SEC: STN=xxx, SECN=2;

// Reconfigure XL antenna Sector

ADD SEC: STN=xxx, SECN=0, SECT=LOCAL_SECTOR, ANTM=2, RFINTERCONN=FALSE, ANT1CN=1,
ANT1SRN=4, ANT1N=N0A, ANT2CN=1, ANT2SRN=4, ANT2N=N1A;

ADD SEC: STN=xxx, SECN=1, SECT=LOCAL_SECTOR, ANTM=2, RFINTERCONN=FALSE, ANT1CN=1,
ANT1SRN=4, ANT1N=N2A, ANT2CN=1, ANT2SRN=4, ANT2N=N3A;

ADD SEC: STN=xxx, SECN=2, SECT=LOCAL_SECTOR, ANTM=2, RFINTERCONN=FALSE, ANT1CN=1,
ANT1SRN=4, ANT1N=N4A, ANT2CN=1, ANT2SRN=4, ANT2N=N5A;


// Reconfigure XL local l cell

ADD LOCELL: LOCELL=1, STN=xxx, SECN=0, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=0, ULFREQ=9813, DLFREQ=10763, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=2, STN=xxx, SECN=1, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=2, ULFREQ=9813, DLFREQ=10763, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=3, STN=xxx, SECN=2, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=4, ULFREQ=9813, DLFREQ=10763, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=4, STN=xxx, SECN=0, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=0, ULFREQ=9838, DLFREQ=10788, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=5, STN=xxx, SECN=1, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=2, ULFREQ=9838, DLFREQ=10788, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=6, STN=xxx, SECN=2, SECT=LOCAL_SECTOR, ULGROUPNO=0,
DLGROUPNO=0, TTW=FALSE, CN1=1, SRN1=4, SN1=4, ULFREQ=9838, DLFREQ=10788, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;



Third Carrier Implementation

//In NodeB

ADD LOCELL: LOCELL=7, STN=xxx, SECN=0, SECT=LOCAL_SECTOR, ULGROUPNO=1,
DLGROUPNO=1, TTW=FALSE, CN1=1, SRN1=4, SN1=1, ULFREQ=9788, DLFREQ=10738, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=8, STN=xxx, SECN=1, SECT=LOCAL_SECTOR, ULGROUPNO=1,
DLGROUPNO=1, TTW=FALSE, CN1=1, SRN1=4, SN1=3, ULFREQ=9788, DLFREQ=10738, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

ADD LOCELL: LOCELL=9, STN=xxx, SECN=2, SECT=LOCAL_SECTOR, ULGROUPNO=1,
DLGROUPNO=1, TTW=FALSE, CN1=1, SRN1=4, SN1=5, ULFREQ=9788, DLFREQ=10738, MXPWR=460,
HISPM=FALSE, RMTCM=FALSE, VAM=FALSE;

HSPA + 21Mbps & HSUPA 5.7Mbps

//In NodeB

SET MACHSPARA: LOCELL=xxx, DYNCODESW=OPEN;
SET MACHSPARA: LOCELL=xxx, SM=EPF;


Step 5 Acti ve Cell From RNC si de
(Note: activate cell when NodeB configuration done)

ACT UCELL: CellId=xxx;
ACT UCELL: CellId=xxx;
ACT UCELL: CellId=xxx;
ACT UCELLHSDPA: CellId=xxx;
ACT UCELLHSDPA: CellId=xxx;
ACT UCELLHSDPA: CellId=xxx;
ACT UCELLHSUPA: CellId=xxx;
ACT UCELLHSUPA: CellId=xxx;
ACT UCELLHSUPA: CellId=xxx;
DSP UCELL: DSPT=BYNODEB, NodeBName="xxx";

Step 6 In M2000 pl ease updates the license from S/2/2/2 configurati on become S/3/3/3
Configurati on


5. ROLL BACK EXECUTION
RNC SIDE

Step 1. RMV ULOCELL: NodeBName="ABC", LoCell=7;
Step 2. RMV USAC: CnOpIndex=0, LAC=xxx, SAC=xxx;
Step 3. RMV UCELL: CellId=xxx;


NodeB SIDE

Step 1. Rel oad the backup .xml script and change the configuration install ati on
become exi sti ng ones

6. Testing after operation
It needs team to verify service on site after operation

7. KPI monitor and CPU load monitor on M2000
a. Monitor after operation:
// KPI monitor and CPU load monitor.
// check alarms which should be compared with the alarms before operation.
// Verify the service through LMT
b. Monitor at first Busy Hour after operation:
// KPI monitor

8. Operation time
Maintenance time window. (00:00 until 04:00 am)








Revision Record

Date Revised Version Change description Author
26/06/2013 1.0
Hendra Wijaya
H00738385
27/06/2013 1.1
Add ucellhsdpa and Add
ucellhsupa (HSPA +
21Mbps & HSUPA
5.7Mbps)
Hendra Wijaya
H00738385
28/06/2013 1.2
Hendra Wijaya
H00738385
01/07/2013 1.3
Hendra Wijaya
H00738385

Вам также может понравиться