TAREA 2 ANLISIS DE PRESIONES AVANZADO

Well Data
Parmetro
Pi
Lw
hz
ct
rw

B
q
hx

Valor
5000
600
50
1,4487E-5
0,25
0,25
4
1,462
500
5455

Unidades
Psi
ft
ft
psi-1
ft
cp
rb/STB
bbl/D
ft

Manuel Eduardo Salinas Vanegas

Cd.: 2004101003

Determinando Los coeficientes y


k yk z =

t D min =

70.6q B
L w(t * P ')r

0.0002637 k y k ztmin

ct r

70.6 50041,462

= 31.2

60011,03

0,000263731,24,267

= 0,2541,448750,252 = 38791,7

(t * P ')max
log(1 / ) = 3.3467 +10.720
(t * P ') pr

(t * P ') max
-15.758

(t * P ') pr

(t * P ') max
+ 10.472

(t * P ') pr

1
41,97
41,97 2
41,97 3
log ( ) = 3.3467 + 10,720 (
) 15,758 (
) + 10,472 (
)

147
147
147
= 4,299 E-6

= 0.18174( tD,min ) + 0.22339( tD,min )2 + 2.1558( tD,min )3


= 0,18174(4,299 6 38791,7) + 0,22339(4,299 6 38791,7)2
+ 2,1558(4,299 6 38791,7)3
= 0,046

Determinando las permeabilidades kx, ky y kz


2
h
502
kz = 301.77ct z
= 301,77 0,25 4 1,4487 5 0,046
0,0077
t i,er-el
kz= 65,29 md
Entonces
= 31,2 = 973,44
=

973,44
= 14,9
65,29

ky= 14,9 md

Manuel Eduardo Salinas Vanegas

Cd.: 2004101003

kx 301.77ct
=
L2w
t i,el- pr

301,770,2541,448750,0466002
2,93

= 24,7

kx= 24,7 md

Determinando los daos en formacin Sm y Sx

k y k z t er
1 P er
- ln
+ 7.43
sm =
ct rw2
2 (t * P ')er

1 89,34
[
(
2 11,03

31,2 0,0043

0,046 0,25 4 1,4487 5 0,25

) + 7,43]

Sm= 1.42

sm + s z =

0.029 k zt el
ct
hz
+ =

Pel

(
t
*

P
')
el

0,029
65,29 0,052
127,1

[
2] = 2,93
50
0,046 0,25 4 1,4487 5 30
+ = 2,93 = 2,93 1,42 = 1,5

Sz= 1.5
Finalmente asumimos un Sx= 0

Manuel Eduardo Salinas Vanegas

Cd.: 2004101003

Вам также может понравиться