Вы находитесь на странице: 1из 192

Page

Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
=Documents+Reports/9
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
55 kW,110 A
ATS22C11Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C11Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
55kW, 110A
ATS22C11Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
55kW, 110A
ATS22C11Q
Schneider Electric\Altivar\ATS22C11Q.ema Schneider Electric\Altivar\ATS22C11Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C11S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C11Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C11Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
75 kW,110 A
ATS22C11S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C11S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
75kW, 110A
ATS22C11S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
75kW, 110A
ATS22C11S6
Schneider Electric\Altivar\ATS22C11S6.ema Schneider Electric\Altivar\ATS22C11S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C11S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C11S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C11S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
75 kW,110 A
ATS22C11S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C11S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
75kW, 110A
ATS22C11S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
75kW, 110A
ATS22C11S6U
Schneider Electric\Altivar\ATS22C11S6U.ema Schneider Electric\Altivar\ATS22C11S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C11S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C14Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C11S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C11S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
75kW, 140A
ATS22C14Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C14Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
75kW, 140A
ATS22C14Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
75kW, 140A
ATS22C14Q
Schneider Electric\Altivar\ATS22C14Q.ema Schneider Electric\Altivar\ATS22C14Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C14S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C14Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C14Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
90kW, 140A
ATS22C14S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C14S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
90kW, 140A
ATS22C14S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
90kW, 140A
ATS22C14S6
Schneider Electric\Altivar\ATS22C14S6.ema Schneider Electric\Altivar\ATS22C14S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C14S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C14S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C14S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
90kW, 140A
ATS22C14S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C14S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
90kW, 140A
ATS22C14S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
90kW, 140A
ATS22C14S6U
Schneider Electric\Altivar\ATS22C14S6U.ema Schneider Electric\Altivar\ATS22C14S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C14S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C17Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C14S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C14S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
90kW, 170A
ATS22C17Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
90kW, 170A
ATS22C17Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
90kW, 170A
ATS22C17Q
Schneider Electric\Altivar\ATS22C17Q.ema Schneider Electric\Altivar\ATS22C17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C17S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C17Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
110kW, 170A
ATS22C17S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
110kW, 170A
ATS22C17S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
110kW, 170A
ATS22C17S6
Schneider Electric\Altivar\ATS22C17S6.ema Schneider Electric\Altivar\ATS22C17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C17S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C17S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
110kW, 170A
ATS22C17S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
110kW, 170A
ATS22C17S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
110kW, 170A
ATS22C17S6U
Schneider Electric\Altivar\ATS22C17S6U.ema Schneider Electric\Altivar\ATS22C17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C17S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C21Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C17S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
110kW, 210A
ATS22C21Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C21Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
110kW, 210A
ATS22C21Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
110kW, 210A
ATS22C21Q
Schneider Electric\Altivar\ATS22C21Q.ema Schneider Electric\Altivar\ATS22C21Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C21S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C21Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C21Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
132kW, 210A
ATS22C21S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C21S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
132kW, 210A
ATS22C21S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
132kW, 210A
ATS22C21S6
Schneider Electric\Altivar\ATS22C21S6.ema Schneider Electric\Altivar\ATS22C21S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C21S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C21S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C21S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
132kW, 210A
ATS22C21S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C21S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
132kW, 210A
ATS22C21S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
132kW, 210A
ATS22C21S6U
Schneider Electric\Altivar\ATS22C21S6U.ema Schneider Electric\Altivar\ATS22C21S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C21S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C25Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C21S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C21S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
132kW, 250A
ATS22C25Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C25Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
132kW, 250A
ATS22C25Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
132kW, 250A
ATS22C25Q
Schneider Electric\Altivar\ATS22C25Q.ema Schneider Electric\Altivar\ATS22C25Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C25S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C25Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C25Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
160kW, 250A
ATS22C25S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C25S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
160kW, 250A
ATS22C25S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
160kW, 250A
ATS22C25S6
Schneider Electric\Altivar\ATS22C25S6.ema Schneider Electric\Altivar\ATS22C25S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C25S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C25S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C25S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
160kW, 250A
ATS22C25S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C25S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
160kW, 250A
ATS22C25S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
160kW, 250A
ATS22C25S6U
Schneider Electric\Altivar\ATS22C25S6U.ema Schneider Electric\Altivar\ATS22C25S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C25S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C32Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C25S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C25S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
160kW, 320A
ATS22C32Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
160kW, 320A
ATS22C32Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
160kW, 320A
ATS22C32Q
Schneider Electric\Altivar\ATS22C32Q.ema Schneider Electric\Altivar\ATS22C32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C32S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C32Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
220kW, 320A
ATS22C32S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
220kW, 320A
ATS22C32S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
220kW, 320A
ATS22C32S6
Schneider Electric\Altivar\ATS22C32S6.ema Schneider Electric\Altivar\ATS22C32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C32S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C32S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
220kW, 320A
ATS22C32S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
220kW, 320A
ATS22C32S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
220kW, 320A
ATS22C32S6U
Schneider Electric\Altivar\ATS22C32S6U.ema Schneider Electric\Altivar\ATS22C32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C32S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C41Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C32S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
220kW, 410A
ATS22C41Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C41Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
220kW, 410A
ATS22C41Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
220kW, 410A
ATS22C41Q
Schneider Electric\Altivar\ATS22C41Q.ema Schneider Electric\Altivar\ATS22C41Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C41S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C41Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C41Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
250kW, 410A
ATS22C41S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C41S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
250kW, 410A
ATS22C41S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
250kW, 410A
ATS22C41S6
Schneider Electric\Altivar\ATS22C41S6.ema Schneider Electric\Altivar\ATS22C41S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C41S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C41S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C41S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
250kW, 410A
ATS22C41S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C41S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
250kW, 410A
ATS22C41S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
250kW, 410A
ATS22C41S6U
Schneider Electric\Altivar\ATS22C41S6U.ema Schneider Electric\Altivar\ATS22C41S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C41S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C48Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C41S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C41S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
250kW, 480A
ATS22C48Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C48Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
250kW, 480A
ATS22C48Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
250kW, 480A
ATS22C48Q
Schneider Electric\Altivar\ATS22C48Q.ema Schneider Electric\Altivar\ATS22C48Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C48S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C48Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C48Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
315kW, 480A
ATS22C48S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C48S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
315kW, 480A
ATS22C48S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
315kW, 480A
ATS22C48S6
Schneider Electric\Altivar\ATS22C48S6.ema Schneider Electric\Altivar\ATS22C48S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C48S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C48S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C48S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
315kW, 480A
ATS22C48S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C48S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
315kW, 480A
ATS22C48S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
315kW, 480A
ATS22C48S6U
Schneider Electric\Altivar\ATS22C48S6U.ema Schneider Electric\Altivar\ATS22C48S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C48S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C59Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C48S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C48S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
355kW, 590A
ATS22C59Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C59Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
355kW, 590A
ATS22C59Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
355kW, 590A
ATS22C59Q
Schneider Electric\Altivar\ATS22C59Q.ema Schneider Electric\Altivar\ATS22C59Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C59S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C59Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C59Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
400kW, 590A
ATS22C59S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C59S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
400kW, 590A
ATS22C59S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
400kW, 590A
ATS22C59S6
Schneider Electric\Altivar\ATS22C59S6.ema Schneider Electric\Altivar\ATS22C59S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22C59S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C59S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C59S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
400kW, 590A
ATS22C59S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22C59S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
400kW, 590A
ATS22C59S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
400kW, 590A
ATS22C59S6U
Schneider Electric\Altivar\ATS22C59S6U.ema Schneider Electric\Altivar\ATS22C59S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22C59S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D17Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22C59S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22C59S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
7.5kW, 17A
ATS22D17Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
7.5kW, 17A
ATS22D17Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
7.5kW, 17A
ATS22D17Q
Schneider Electric\Altivar\ATS22D17Q.ema Schneider Electric\Altivar\ATS22D17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D17S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D17Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D17Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
9kW, 17A
ATS22D17S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
9kW, 17A
ATS22D17S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
9kW, 17A
ATS22D17S6
Schneider Electric\Altivar\ATS22D17S6.ema Schneider Electric\Altivar\ATS22D17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D17S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D17S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D17S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
9kW, 17A
ATS22D17S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
9kW, 17A
ATS22D17S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
9kW, 17A
ATS22D17S6U
Schneider Electric\Altivar\ATS22D17S6U.ema Schneider Electric\Altivar\ATS22D17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D17S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D32Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D17S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D17S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
15kW, 32A
ATS22D32Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
15kW, 32A
ATS22D32Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
15kW, 32A
ATS22D32Q
Schneider Electric\Altivar\ATS22D32Q.ema Schneider Electric\Altivar\ATS22D32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D32S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D32Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D32Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
18.5kW, 32A
ATS22D32S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
18.5kW, 32A
ATS22D32S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
18.5kW, 32A
ATS22D32S6
Schneider Electric\Altivar\ATS22D32S6.ema Schneider Electric\Altivar\ATS22D32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D32S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D32S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D32S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
18.5kW, 32A
ATS22D32S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
18.5kW, 32A
ATS22D32S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
18.5kW, 32A
ATS22D32S6U
Schneider Electric\Altivar\ATS22D32S6U.ema Schneider Electric\Altivar\ATS22D32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D32S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D47Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D32S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D32S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
22kW, 47A
ATS22D47Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D47Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
22kW, 47A
ATS22D47Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
22kW, 47A
ATS22D47Q
Schneider Electric\Altivar\ATS22D47Q.ema Schneider Electric\Altivar\ATS22D47Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D47S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D47Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D47Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
30kW, 47A
ATS22D47S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D47S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
30kW, 47A
ATS22D47S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
30kW, 47A
ATS22D47S6
Schneider Electric\Altivar\ATS22D47S6.ema Schneider Electric\Altivar\ATS22D47S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D47S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D47S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D47S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
30kW, 47A
ATS22D47S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D47S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
30kW, 47A
ATS22D47S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
30kW, 47A
ATS22D47S6U
Schneider Electric\Altivar\ATS22D47S6U.ema Schneider Electric\Altivar\ATS22D47S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D47S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D62Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D47S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D47S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
30kW, 62A
ATS22D62Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D62Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
30kW, 62A
ATS22D62Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
30kW, 62A
ATS22D62Q
Schneider Electric\Altivar\ATS22D62Q.ema Schneider Electric\Altivar\ATS22D62Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D62S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D62Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D62Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
37kW, 62A
ATS22D62S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D62S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
37kW, 62A
ATS22D62S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
37kW, 62A
ATS22D62S6
Schneider Electric\Altivar\ATS22D62S6.ema Schneider Electric\Altivar\ATS22D62S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D62S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D62S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D62S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
37kW, 62A
ATS22D62S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D62S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
37kW, 62A
ATS22D62S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
37kW, 62A
ATS22D62S6U
Schneider Electric\Altivar\ATS22D62S6U.ema Schneider Electric\Altivar\ATS22D62S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D62S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D75Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D62S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D62S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
37kW, 75A
ATS22D75Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D75Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
37kW, 75A
ATS22D75Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
37kW, 75A
ATS22D75Q
Schneider Electric\Altivar\ATS22D75Q.ema Schneider Electric\Altivar\ATS22D75Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D75S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D75Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D75Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
45kW, 75A
ATS22D75S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D75S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
45kW, 75A
ATS22D75S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
45kW, 75A
ATS22D75S6
Schneider Electric\Altivar\ATS22D75S6.ema Schneider Electric\Altivar\ATS22D75S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D75S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D75S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D75S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
45kW, 75A
ATS22D75S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D75S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
45kW, 75A
ATS22D75S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
45kW, 75A
ATS22D75S6U
Schneider Electric\Altivar\ATS22D75S6U.ema Schneider Electric\Altivar\ATS22D75S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D75S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D88Q/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D75S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D75S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88Q
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
45kW, 88A
ATS22D88Q
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D88Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88Q
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
45kW, 88A
ATS22D88Q
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
45kW, 88A
ATS22D88Q
Schneider Electric\Altivar\ATS22D88Q.ema Schneider Electric\Altivar\ATS22D88Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88Q
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D88S6/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D88Q.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D88Q/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input power supply
(24 VDC)
Modbus RJ45
Input for PTC probes
Control power supply
(230 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
55kW, 88A
ATS22D88S6
LI2
START
LI3 +24V R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D88S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(230 VAC)
Relay R1 Logic input power supply
(24 VDC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 +24V
-U2
Altistart 22
55kW, 88A
ATS22D88S6
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
55kW, 88A
ATS22D88S6
Schneider Electric\Altivar\ATS22D88S6.ema Schneider Electric\Altivar\ATS22D88S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATS22D88S6U/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D88S6.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATS22D88S6/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6U
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Relay R2 Logic input common
(110 VAC)
Modbus RJ45
Input for PTC probes
Control power supply
(110 VAC)
Programable logic inputs Relay R1
Motor
Power Supply
SH
LI1
STOP
R2C R2A R1A R2B L3
5
COM
PTC2 PTC1
CL2 CL1
-U1
Altistart 22
55kW, 88A
ATS22D88S6U
LI2
START
LI3 NC R1B R1C L2
3
L1
1
2
T1
4
T2
6
T3
PE1
PE2
Schneider Electric\Altivar\ATS22D88S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6U
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Input for PTC probes
Relay R2 Control power supply
(110 VAC)
Relay R1 Logic input common
(110 VAC)
Programable logic inputs
Modbus RJ45
SH PTC2 PTC1
R2C R2A R1A R2B CL2 CL1 R1B R1C LI1
STOP
COM LI2
START
LI3 NC
-U2
Altistart 22
55kW, 88A
ATS22D88S6U
Motor
Power Supply
L3
5
2
T1
4
T2
6
T3 PE2
L2
3
L1
1
PE1
-U2
Altistart 22
55kW, 88A
ATS22D88S6U
Schneider Electric\Altivar\ATS22D88S6U.ema Schneider Electric\Altivar\ATS22D88S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altistart22
ATS22D88S6U
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
=Altivar32+ATV32H018M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATS22D88S6U.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
=Altistart22+ATS22D88S6U/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H018M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H018M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
0.18kW, 2.8A
ATV32H018M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H018M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H018M2.ema Schneider Electric\Altivar\ATV32H018M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.18kW, 2.8A
ATV32H018M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.18kW, 2.8A
ATV32H018M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H018M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H037M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H018M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H018M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H037M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
0.37kW, 5A
ATV32H037M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H037M2.ema Schneider Electric\Altivar\ATV32H037M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.37kW, 5A
ATV32H037M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.37kW, 5A
ATV32H037M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H037N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H037M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H037M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H037N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
0.37kW, 2.1A
ATV32H037N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H037N4.ema Schneider Electric\Altivar\ATV32H037N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.37kW, 2.1A
ATV32H037N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.37kW, 2.1A
ATV32H037N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H037N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H055M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H037N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H037N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H055M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
0.55kW, 6.7A
ATV32H055M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H055M2.ema Schneider Electric\Altivar\ATV32H055M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.55kW, 6.7A
ATV32H055M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.55kW, 6.7A
ATV32H055M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H055N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H055M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H055M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H055N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
0.55kW, 2.8A
ATV32H055N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H055N4.ema Schneider Electric\Altivar\ATV32H055N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.55kW, 2.8A
ATV32H055N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.55kW, 2.8A
ATV32H055N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H055N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H075M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H055N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H055N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H075M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
0.75kW, 8.5A
ATV32H075M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H075M2.ema Schneider Electric\Altivar\ATV32H075M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.75kW, 8.5A
ATV32H075M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.75kW, 8.5A
ATV32H075M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32H075N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H075M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H075M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32H075N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
0.75kW, 3.6A
ATV32H075N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32H075N4.ema Schneider Electric\Altivar\ATV32H075N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
0.75kW, 3.6A
ATV32H075N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
0.75kW, 3.6A
ATV32H075N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32H075N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HD11N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32H075N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32H075N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD11N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HD11N4.ema
Filter settings
Normal
LI6 input
switch
PTC
LI
SW2 SW1
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
DC bus (+)
polarity
Power Supply
Motor
DC bus (-)
polarity
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
PBe PB
-
PC
+
PA PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
11kW, 36.6A
ATV32HD11N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD11N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HD11N4.ema Schneider Electric\Altivar\ATV32HD11N4.ema
Motor
Power Supply
DC bus (-)
polarity (+ polarity)
Output to braking resistor
DC bus (+)
polarity
-U2
Altivar 32
11kW, 36.6A
ATV32HD11N4
PE2
W
T3
V
T2
U
T1 PBe PB
-
PC
+
PA
PE1 L1
R
L2
S
L3
T
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
11kW, 36.6A
ATV32HD11N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD11N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HD15N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HD11N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HD11N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD15N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HD15N4.ema
Filter settings
Normal
LI6 input
switch
PTC
LI
SW2 SW1
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
DC bus (+)
polarity
Power Supply
Motor
DC bus (-)
polarity
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
PBe PB
-
PC
+
PA PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
15kW, 47.3A
ATV32HD15N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD15N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HD15N4.ema Schneider Electric\Altivar\ATV32HD15N4.ema
Motor
Power Supply
DC bus (-)
polarity (+ polarity)
Output to braking resistor
DC bus (+)
polarity
-U2
Altivar 32
15kW, 47.3A
ATV32HD15N4
PE2
W
T3
V
T2
U
T1 PBe PB
-
PC
+
PA
PE1 L1
R
L2
S
L3
T
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
15kW, 47.3A
ATV32HD15N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HD15N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU11M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HD15N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HD15N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
1.1kW, 11.5A
ATV32HU11M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11M2.ema Schneider Electric\Altivar\ATV32HU11M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
1.1kW, 11.5A
ATV32HU11M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
1.1kW, 11.5A
ATV32HU11M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU11N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU11M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
1.1kW, 5A
ATV32HU11N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11N4.ema Schneider Electric\Altivar\ATV32HU11N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
1.1kW, 5A
ATV32HU11N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
1.1kW, 5A
ATV32HU11N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU11N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU15M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU11N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU11N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
1.5kW, 14.8A
ATV32HU15M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15M2.ema Schneider Electric\Altivar\ATV32HU15M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
1.5kW, 14.8A
ATV32HU15M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
1.5kW, 14.8A
ATV32HU15M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU15N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU15M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
1.5kW, 6.5A
ATV32HU15N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15N4.ema Schneider Electric\Altivar\ATV32HU15N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
1.5kW, 6.5A
ATV32HU15N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
1.5kW, 6.5A
ATV32HU15N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU15N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU22M2/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU15N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU15N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22M2
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22M2.ema
Normal
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2/N
S
-U1
Altivar 32
2.2kW, 20.1A
ATV32HU22M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22M2
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22M2.ema Schneider Electric\Altivar\ATV32HU22M2.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
2.2kW, 20.1A
ATV32HU22M2
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2/N
S
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
2.2kW, 20.1A
ATV32HU22M2
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22M2
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU22N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22M2.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU22M2/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
2.2kW, 8.7A
ATV32HU22N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22N4.ema Schneider Electric\Altivar\ATV32HU22N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
2.2kW, 8.7A
ATV32HU22N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
2.2kW, 8.7A
ATV32HU22N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU22N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU30N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU22N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU22N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU30N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU30N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
3kW, 11.1A
ATV32HU30N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU30N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU30N4.ema Schneider Electric\Altivar\ATV32HU30N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
3kW, 11.1A
ATV32HU30N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
3kW, 11.1A
ATV32HU30N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU30N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU40N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU30N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU30N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU40N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU40N4.ema
LI6 input
switch
PTC
LI
SW2 SW1
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Power Supply
Motor
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
DC bus (+)
polarity
DC bus (-)
polarity
PBe PB PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
4kW, 13.7A
ATV32HU40N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
-
PC
+
PA
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU40N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU40N4.ema Schneider Electric\Altivar\ATV32HU40N4.ema
Motor
Power Supply
(+ polarity)
Output to braking resistor
DC bus (+)
polarity
DC bus (-)
polarity
-U2
Altivar 32
4kW, 13.7A
ATV32HU40N4
PE2
W
T3
V
T2
U
T1 PBe PB
PE1 L1
R
L2
S
L3
T
-
PC
+
PA
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
4kW, 13.7A
ATV32HU40N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU40N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU55N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU40N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU40N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU55N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU55N4.ema
Filter settings
Normal
LI6 input
switch
PTC
LI
SW2 SW1
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
DC bus (+)
polarity
Power Supply
Motor
DC bus (-)
polarity
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
PBe PB
-
PC
+
PA PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
5.5kW, 20.7A
ATV32HU55N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU55N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU55N4.ema Schneider Electric\Altivar\ATV32HU55N4.ema
Motor
Power Supply
DC bus (-)
polarity (+ polarity)
Output to braking resistor
DC bus (+)
polarity
-U2
Altivar 32
5.5kW, 20.7A
ATV32HU55N4
PE2
W
T3
V
T2
U
T1 PBe PB
-
PC
+
PA
PE1 L1
R
L2
S
L3
T
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
5.5kW, 20.7A
ATV32HU55N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU55N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
+ATV32HU75N4/1
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU55N4.ema
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
+ATV32HU55N4/3
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU75N4
complete
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
2
4
14.06.2010
Schneider Electric
GmbH
1
2
=
Name
5
Schneider Electric\Altivar\ATV32HU75N4.ema
Filter settings
Normal
LI6 input
switch
PTC
LI
SW2 SW1
IT system
Logic input
switch
Source
Sink Ext
Sink Int
(+ polarity)
Output to braking resistor
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
DC bus (+)
polarity
Power Supply
Motor
DC bus (-)
polarity
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
PBe PB
-
PC
+
PA PE2
PE1
W
T3
V
T2
U
T1
L1
R
L2
S
-U1
Altivar 32
7.5kW, 26.5A
ATV32HU75N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
L3
T
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
1
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU75N4
function oriented
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
3
4
14.06.2010
Schneider Electric
GmbH
2
2
=
Name
5
Schneider Electric\Altivar\ATV32HU75N4.ema Schneider Electric\Altivar\ATV32HU75N4.ema
Motor
Power Supply
DC bus (-)
polarity (+ polarity)
Output to braking resistor
DC bus (+)
polarity
-U2
Altivar 32
7.5kW, 26.5A
ATV32HU75N4
PE2
W
T3
V
T2
U
T1 PBe PB
-
PC
+
PA
PE1 L1
R
L2
S
L3
T
Filter settings
Normal
IT system
Logic input
switch
Source
Sink Ext
Sink Int
LI6 input
switch
PTC
LI
SW2 SW1
RJ45
Common point contact
of programmable relay R1
NO contact of R2
programmable relay
Programable logic inputs STO
(Safe Torgue Off)
safety function
input
Programable
logic input
or
Input for PTC
probes
Logic input
power supply
External power
supply for control
circuit / Internal
power supply
for STO
Programable
logic input
or
Pulse input
20 kpps
Power supply
for reference
potentiometer
Analog
voltage
input
Analog I/O
common
Analog current
input
Analog voltage
input Logic output
Analog I/O
common
Voltage or current
analog output
(collector)
Analog I/O
common
-U2
Altivar 32
7.5kW, 26.5A
ATV32HU75N4
R1C R1A LI4 LI3 LI2 R2C R2A R1B LI1 LI5 LI6 +24V STO P24
AI1 +10V COM1 AI3 AI2 LO- LO+ COM3 AO1 COM2
Page
Page
Schneider Altivar 32 & Altistart 22 Project
Ed.
2
Original
EPLAN Software & Service
KAF +
Date
Date
Replaced by
Altivar32
ATV32HU75N4
front view
1
Modification
0 7 6
Appr
Replacement of
8 9 3
201
4
14.06.2010
Schneider Electric
GmbH
3
2
=
Name
5
Schneider Electric\Altivar\ATV32HU75N4.ema

Вам также может понравиться