PLC PWS

P.
PLC PWS

P.L.C. P.L.C.-CPU

P PLC , PLC PLC


,, PLC_DRIVER
,.(MAIL TO :

pws@hitech-lcd.com.tw FAX: -886-2-22183060,,


ADP3 ( PLC PWS .DOC PLC
PWS .pdf).
: P.L.C. PWS- PWS P.L.C._CPU

PWS- P.L.C.

The Driver File

P513.TSK
P553.TSK
P503.TSK
P523.TSK
P383.TSK

P003.TSK
P013.TSK
P023.TSK
PD13.TSK
PD23.TSK
PZ03.TSK
PH03.TSK
PH23.TSK
P303.TSK
PF03.TSK
PA13.TSK
PA03.TSK
P413.TSK
P403.TSK
PB13.TSK
PWS WORKSTATION

For P.L.C. Brand Name

Allen-Bradley Micrologix 1000/1500


Allen-Bradley PLC-5
Allen-Bradley SLC 5/03 & 5/04
AB IQ Master Servo controller
ABB COML1(slave mode, binary)
Computer (as master)
Computer (as slave)
Computer (as master) V2
Delta DVP Series
Delta VFD-B Inverter
ERO TFS/THS/LFS
Facon FB Series RS232c
Facon FB Series RS485
FAMA OMC/SC-500 Series
Festo FPC/FEC Series
Fuji NB Series
Fuji Micrex-F Series
GE Series 90 CCM
GE Series 90 SNP
Hitachi EC Series
Hitech Electronics Corp.

Page
p-4
p-6
p-9
p-10
p-10
p-10
p-11
p-12
p-13
p-13
p-14
p-15
p-16
p-18

P-1

P
The Driver File

P-2

For P.L.C. Brand Name

Page

PB03.TSK
PH13.TSK
PE63.TSK
PE53.TSK
PK53.TSK
PK63.TSK
PK33.TSK
PK13.TSK
PK03.TSK
PC03.TSK
P913.TSK
P943.TSK
P803.TSK
PL03.TSK
PL73.TSK
PL53.TSK
PL23.TSK
PL63.TSK
PL43.TSK
P603.TSK
P123.TSK
P703.TSK
P713.TSK
P723.TSK
P853.TSK
P833.TSK
P813.TSK
P823.TSK
P843.TSK
P863.TSK
P803.TSK
P333.TSK
P323.TSK
P343.TSK
P303.TSK
P313.TSK
PL33.TSK

Hitachi H Series
HUST-CNC Controller
IDEC FA-2J
IDEC Micro-3
Jetter NANO-B
Jetter DELTA
Keyence KV Series
Klockner Moeller PS316
Klockner Moeller PS4-201
KOYO SA21
TI 435 / Koyo SU Series / Koyo Direct DL Series
KOYO K-sequence
LG GLOFA GM6 Series
LG K10/60H/200H
LG K200S
LG K300S
LG K500H/1000H
LG Master-K10S/30S/60S/100S
LIYAN PLC-CX
Matsushita FP Series
MIRLE DX Controller
Mitsubishi FX Series
Mitsubishi FX-10GM/20GM Series
Mitsubishi FX2N Series
Mitsubishi A0J2 CPU Series
Mitsubishi A1N CPU Series
Mitsubishi A1S/A2S CPU Port
Mitsubishi A2A/A2AS CPU Port
Mitsubishi A3N/A1SH CPU Series
Mitsubishi AnA/U LINK Series
Mitsubishi AnN/S LINK Series
Modbus master
Modbus slave
Modicon PC984 (RTU mode; master)
Modicon PC984 (RTU mode; slave)
Modicon TSX QUANTUM Series
NHP Microlink ML-14

P000.TSK

Null ( No connection with PLC )

p-19
p-20
p-21
p-22
p-22
p-23
p-24
p-25
p-26
p-27
p-28
p-29
p-31
p-32
p-32
p-34
p-34
p-34
p-34
p-34
p-34
p-34
p-36
p-36
p-57

PWS WORKSTATION


The Driver File

P103.TSK
P133.TSK
P113.TSK

PLC PWS
For P.L.C. Brand Name

Omron C Series
Omron CS1 Series
Omron CV Series

p-38

PP13.TSK

PARKER 6K/6000 Motiom Controller

PS03.TSK
PY53.TSK
PS13.TSK
PN13.TSK
P203.TSK

SAIA PCD1
Sharp JW10/20 Series
SHINKO CnT Series Temperature Controller
SIDE MIDA 20/20D
Simatic S5 Series (90U, 95U, 115U, 135U) via PG port

P213.TSK

Simatic S5 3964R RK512

P253.TSK
P263.TSK
P277.TSK
P273.TSK
P273.TSK
PD03.TSK
PY23.TSK
PY03.TSK
PY13.TSK
PW03.TSK
P923.TSK
P913.TSK
P903.TSK
PT03.TSK
PT13.TSK
P013.TSK

Simatic S7-200 Series (1-to-1 link PPI port)


Simatic S7 3964R-CP340
Simatic S7-300 Series (via HMI adapter)
Simatic S7-300 Series (via MPI cpu port)
Simatic S7-300 Series (via PC adapter)
Square D Model 400-700
Taian N2 Inverter Series
Taian TP01 Series
Taian TP02 Series
Telemecanique TSX Micro
TI 325/330 / KOYO SA Series
TI 435 / Koyo SU Series / Koyo Direct DL Series
TI 500/505
Toshiba M20/M40
Toshiba T1/T2
Unidriver UD70 User mode 6

P323.TSK

Unidriver UD70 mode 15 modbus slave protocol

PN23.TSK
PY63.TSK

Vigor M Series
Yokogawa FA-M3 Series

PWS WORKSTATION

Page
p-37

Hitech Electronics Corp.

p-39
p-40
p-41
p-42
p-45
p-43
p-48
p-47
p-49
p-23
p-50
p-51
p-52
p-53
p-54
p-55

P-3

p513.tsk= AB Micrologic1000/1500
1.ADP3 PLC

Device Type /

Aux. Address
Output file
O:0.n
n=0-3
0
Input file
I:1.n
n=0-3
1
Status file
S2:nn
nn=0-65
2
Bit file
B3:nnn
nnn=0-255
3
Timer flag
T4:nnn
nnn=0-255
4
Timer Preset Value
T4:nnn.pre
nnn=0-255
5
Timer Accumulator
T4:nnn.acc
nnn=0-255
6
Value
Counter flag
C5:nnn
nnn=0-255
7
Counter Preset Value C5:nnn.pre
nnn=0-255
8
Counter Accumulator C5:nnn.acc
nnn=0-255
9
Value
Control file
R6:nnn
nnn=0-255
10
Control Size of Bit
R6:nnn.len
nnn=0-255
11
Array
Control Reserved file
R6:nnn.pos
nnn=0-255
12
Integer file
N7:nnn
nnn=0-255
13
**T he W ork station doesnot support block read for registers in
Control files.
**You should open those files in the PLC that the W ork station

0
0
2
3
4
4
4

Word
Word
Word
Word
Word
Word
Word

R/W
9
9
9
9
9
9
9

5
5
5

Word
Word
Word

9
9
9

6
6

Word
Word

9
9

9
Word
6
9
Word
7
Tim er, Counter, and
will access.

2.ADP3 PLC

Output
O:0.n/bb
n=0-3; bb=0-15
Input
I:1.n/bb
n=0-3; bb=0-15
Status
S2:nn/bb
nn=0-65; bb=0-15
Bit
B3:nnn/bb
nnn=0-255; bb=0-15
Timer
T4:nnn/bb
nnn=0-255; bb=0-15
Timer Preset Value T4:nnn.pre/bb
nnn=0-255; bb=0-15
Timer Accumulator T4:nnn.acc/bb nnn=0-255; bb=0-15
Value
Counter flag
C5:nnn/bb
nnn=0-255; bb=0-15
Counter Preset
C5:nnn.pre/bb nnn=0-255; bb=0-15
Value
Counter
C5:nnn.acc/bb nnn=0-255; bb=0-15
Accumulator Value
Control
R6:nnn/bb
nnn=0-255; bb=0-15
Control Size of Bit
R6:nnn.len/bb
nnn=0-255; bb=0-15
Array
Control Reserved
R6:nnn.pos/bb nnn=0-255; bb=0-15
Integer
N7:nnn/bb
nnn=0-255; bb=0-15
**T he W ork station doesnot support block read for bits
files.
P-4

Device Type /
Aux. Address

0xC0
0xC1
0xC2
0xC3
0xC4
0xC5
0xC6

0-15
0-15
0-15
0-15
0-15
0-15
0-15

Word
Word
Word
Word
Word
Word
Word

R/W
9
9
9
9
9
9
9

0xC7
0xC8

0-15
0-15

Word
Word

9
9

0xC9

0-15

Word

0xCA
0xCB

0-15
0-15

Word
Word

9
9

9
Word
0xCC
0-15
9
Word
0xCD
0-15
in T im er, Counter, and Control

PWS WORKSTATION

PLC PWS

3. : PW S to RS232C of PLC 1761-CBL-PM02

4.: PWS PLC


A. P.L.C.
B. PWS-
a./

RS232C

b. NODE ADDRESS.

c.

19200 bps

d.

e. Com Port

1. 8-bit
2.Parity
NONE
1-bit
3.
FULL DUPLEX

f. CRC ERROR Check

YES

PWS WORKSTATION

COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLCN(PLC)
1. ADP3
SW5=OFF
2. PWS-
SW5=ON

Hitech Electronics Corp.

P-5

P503=AB SLC-503/504 PWS


1.ADP3 PLC

Register Type
Format
Range
Output file
Input file
Status file
Bit file
Timer file

Counter file

Control file

Integer file

O:nn
I:nn
S:nn
Bfff:nnn
B:nnn
Tfff:nnn
T:nnn
Tfff:nnn.PRE
T:nnn.PRE
Tfff:nnn.ACC
T:nnn.ACC
Cfff:nnn
C:nnn
Cfff:nnn.PRE
C:nnn.PRE
Cfff:nnn.ACC
C:nnn.ACC
Rfff:nnn
R:nnn
Rfff:nnn.LEN
R:nnn.LEN
Rfff:nnn.POS
R:nnn.POS
Nfff:nnn
N:nnn

Data Size

nn= 0-30
nn= 0-30
nn=0-31
fff= 3 or 10-255;
default file is 3 if fff omitted; nnn=0-255
fff= 4 or 10-255;
default file is 4 if fff omitted; nnn=0-255

Word
Word
Word
Word

fff=5 or 10-255;
default file is 5 if fff omitted; nnn=0-255

Word

fff=6 or 10-255;
default file is 6 if fff omitted; nnn=0-255

Word

fff=7 or 10-255;
default file is 7 if fff omitted; nnn=0-255

Word

Word

** 30 Words
**T he W ork station doesnot support block read for registers in Tim er, Counter, and
Control files.
**You should open those files in the PLC that the W ork station will access.

P-6

PWS WORKSTATION

PLC PWS

2 .ADP3 PLC

Relay Type

Format

Output file
Input file
Status file
Bit file

O:nn/bb
I:nn/bb
S:nn/bb
Bfff:nnn/bb

Timer file

Tfff:nnn/bb
Tfff:nnn.PRE/bb
Tfff:nnn.ACC/bb
Tfff:nnn.EN
Tfff:nnn.TT
Tfff:nnn.DN
Cfff:nnn/bb
Cfff:nnn.PRE/bb
Cfff:nnn.ACC/bb
Cfff:nnn.CU
Cfff:nnn.CD
Cfff:nnn.DN
Cfff:nnn.OV
Cfff:nnn.UN
Rfff:nnn/bb
Rfff:nnn.LEN/bb
Rfff:nnn.POS/bb
Rfff:nnn.EN
Rfff:nnn.EU
Rfff:nnn.DN
Rfff:nnn.EM
Rfff:nnn.ER
Rfff:nnn.UL
Rfff:nnn.IN
Rfff:nnn.FD
Nfff:nnn/bb

Counter file

Control file

Integer file

Range
nn= 0-30; bb= 0-15
nn= 0-30; bb= 0-15
nn= 0-31; bb= 0-15
fff= 3 or 10-255;
default file is 3 if fff omitted;
nnn=0-255; bb=0-15
fff= 4 or 10-255;
default file is 4 if fff omitted;
nnn=0-255; bb=0-15

fff=5 or 10-255;
default file is 5 if fff omitted;
nnn=0-255; bb=0-15

fff=6 or 10-255;
default file is 6 if fff omitted;
nnn=0-255; bb=0-15

fff=7 or 10-255;
default file is 7 if fff omitted;
nnn=0-255; bb=0-15

** 480 Bits
**T he W ork station doesnot support block read for bits in T im er, Counter, and Control
files.

PWS WORKSTATION

Hitech Electronics Corp.

P-7

3 : PWS to RS232C of PLC SLC-503/504

4.: PWS PLC


A. P.L.C.
B. PWS-
a./

RS232C SLC-503/504

b. NODE ADDRESS.

c.
d.

9600/19200 bps
1. 8-bit
2.Parity NONE
3. 1-bit
FULL DUPLEX
YES

e. SLC-503/504
f. BCC ERROR Check

P-8

COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLCN(PLC)

PWS WORKSTATION

PLC PWS

P383.tsk=ABB COMLI (SLAVE MODE)


1.ADP3 PLC

Word IO
MWnnnnn
Word Register
RWnnnn
** Word Register (OCT)

Bit IO
Mnnnnn

nnnnn=0 37760(16 )
nnnn=0 - 3071

Word(16Bit)
Word(16Bit)

nnnnn=0-37777

2.:
a.PWS- to PLC RS232 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

PWS WORKSTATION

RS232
01(PLC1-247)
9600 bps
8-bit, ODD , 1-bit

Hitech Electronics Corp.

RS232

P-9

P003=Computer (as master) PWS-


P013=Computer (as slave) PWS-
1.ADP3 PLC

Data Register

Wnnnn

nnnn=0~4095


Bit Relay

Bnnnn

nnnn=0~1023

Word(16Bit)

Block

2.:
a.PWS- to PLC RS232 PORT

[] PC
3.: PWS PLC
A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-10

RS232C

9600 bps
8-bit, NONE , 1-bit

RS232C

PWS WORKSTATION

PLC PWS

PD13=DELTA DVP PLC PWS-


1.ADP3 PLC

S_Data
X_Data
Y_Data
M_Data
T_Register
C_Register
D_Register

Snnnn
Xnnn
Ynnn
Mnnnn
Tnnn
Cnnn
Dnnnn

nnnn=0-1008 ( 16 )
nnn= 0-360 ( 20 ) []
nnn= 0-360 ( 20 ) []
nnnn=0-1264 ( 16 )
nnn= 0-255
nnnn=0-255
nnnn=0-1279


S_Data
X_Data
Y_Data
M_Data
T_Coil
C_Coil

Snnnn
Xnnn
Ynnn
Mnnnn
Tnnn
Cnnn

nnn=0-1023
nnn=0-377 (8 )
nnn=0-377 (8 )
nnnn=0-1279
nnn=0-255
nnn=0-255

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)

[] X_Data Y_Data 8 X0~X7,X10~X17,X20~X27,X30~X37,


20 (16Bit)
2.:
a.PWS- to PLC RS232 PORT
DELTA 8-pin male (
PC DELTA DVP PLC )

3.: PWS PLC


A. P.L.C.
a./
b.(STATION No).
c.
d.

PWS WORKSTATION

RS232C
01
9600 bps
7-bit, EVEN , 2-bit

B. PWS-
COM1 or COM2=RS232
1. ADP3
PLC=01

Hitech Electronics Corp.

P-11

PZ03=ERO TFS/THS/LFS PLC PWS


1.ADP3 PLC

Word Register

Bit Relay

mmm:Wnnn

mmm=0-255 ; nnn=0-529

Word(16Bit)

mmm:Bnnn

mmm=0-255 ; nnn=0-342

2.:
a.PWS- to PLC RS485 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-12

RS485

9600 bps
8-bit, EVEN , 1-bit

RS485

PWS WORKSTATION

PLC PWS

PH03=FACON FB PLC PWS-


1.ADP3 PLC

Input Relay
WXnnn
nnn=0-9984; ( 0 8 )
Output Relay
WYnnn
nnn=0-9984; ( 0 8 )
Internal Relay
WMnnnn
nnnn=0-9984; ( 0 8 )
Special Relay
WMnnnn
nnnn=0-9984; ( 8 )
Step Relay
WSnnn
nnn=0-9984; ( 0 8 )
Timer Present Value
RTnnnn
nnnn=0-9999
Counter Present Value
RCnnnn
nnnn=0-9999
Data Register
Rnnnnn
nnnn=0-65534
Data Register
Dnnnnn
nnnn=0-65534
** 64Words

Input Relay
Output Relay
Internal Relay
Step Relay
Timer Flag
Counter Flag

Xnnnn
Ynnnn
Mnnnn
Snnnn
Tnnnn
Cnnnn

nnn=0-9999
nnn=0-9999
nnnn=0-9999
nnn=0-9999
nnn=0-9999
nnn=0-9999

Word
Word
Word
Word
Word
Word
Word
Double Word
Word

Block
. X32( 0 8 )
. Y8 ( 0 8 )
. M0 ( 0 8 )
. S16 ( 0 8 )

2.: PWS to RS232C of FB-MC type

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).

RS232C
1

c.

9600/19200 bps

COM1 or COM2 ==> RS232


1. ADP3
PLC01(PLC)
1. ADP3

d.

7-bit, even,1-bit

2. PWS-

SW5=OFF
SW5=ON

PWS WORKSTATION

Hitech Electronics Corp.

P-13

PF03=Festo FPC PLC PWS-


1.ADP3 PLC

Input
Output
Flag
Timer
Counter
Register
Timer_Preset
Counter_Preset

Input
Output
Flag
Timer
Counter
Timer_on
Timer_off

IWnnn
QWnnn
FWnnnn
TWnnn
CWnnn
Rnnn
TPnnn
CPnnn

nnn=0-255
nnn=0-255
nnnn=0-9999
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)

Innn.bb
Qnnn.bb
Fnnnn.bb
Tnnn
Cnnn
TONnnn
TOFFnnn

nnn=0-255; bb=0-15
nnn=0-255; bb=0-15
nnnn=0-9999; bb=0-15
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255

Block
b=0 . I20.0
b=0 . Q20.0
b=0 . F20.0

2.:
a.PWS- to (TTL RS232C cable)
Festo TTL RS232C

6-pin PLC-port
PLC-port9-pin
9-pin male 9-pin female

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-14

RS232

9600 bps
8-bit, NONE, 1-bit

COM1 or COM2=RS232

PWS WORKSTATION

PLC PWS

PA13=Fuji NB PLC PWS-


1.ADP3 PLC

Data Register
Special Register
Timer Current Value
Counter Current Value
Input Relay
Output Relay
Internal Relay
Latch Relay
Special Relay
Step Relay

Dnnn
Dnnnn
TNnnn
CNnn
WXnn
WYnn
WMnn
WLnn
WMnnn
WSnnn

nnn=hex number 0-3ff


nnnn=hex number 8000-80ff
nnn=hex number 0-1ff
nn=hex number 0-ff
nn=hex number 0-1f
nn=hex number 0-1f
nn=hex number 0-3f
nn=hex number 0-3f
nnn=hex nuumber 800-81f
nnn=hex number 0-3f

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word


Timer output
Counter output
Input Relay
Output Relay
Internal Relay
Latch Relay
Special Relay
Step Relay

Tnnn
Cnn
Xnnn
Ynnn
Mnnn
Lnnn
Mnnnn
Snnn

nnn=hex number 0-1ff


nn=hex number 0-ff
nnn=hex number 0-1ff
nnn=hex number 0-1ff
nnn=hex number 0-3ff
nnn=hex number 0-3ff
nnnn=hex number 8000-81ff
nnn=hex number 0-3ff

Block
0
0
0
0
0
0
0
0

2.: PW S to RS422 of NB/NS/NJ-CPU port

3.: PWS PLC


A. P.L.C.
a./
RS422
b.(STATION No).

c.
19200 bps
d.
8-bit,ODD,1-bit
e. P.L.C. password
none or 0000-9999
PWS WORKSTATION

B. PWS-
COM= RS422

0000 or 9999= ****

Hitech Electronics Corp.

P-15

P403=GE-Fanuc 90-SNP PWS-


1.ADP3 PLC

Discrete Inputs

%Innnnn

nnnnn=1-12288; 1 16+1

Word

Discrete Outputs

%Qnnnnn

nnnnn=1-12288; 1 16+1

Word

Discrete Temporaries

%Tnnn

nnn=1-256; 1 16 +1

Word

Discrete Internals

%Mnnnnn

nnnnn=1-12288; 1 16+1

Word

%SA Discretes

%SAnnn

nnn=1-128; 1 16 +1

Word

%SB Discretes

%SBnnn

nnn=1-128; 1 16 +1

Word

%SC Discretes

%SCnnn

nnn=1-128; 1 16 +1

Word

%S Discretes

%Snnn

nnn=1-128; 1 16 +1

Word

Genius Global Data

%Gnnnn

nnnn=1-7680; 1 16 +1

Word

Registers

%Rnnnnn

nnnnn=1-16384

Word

Analog Inputs

%AInnnn

nnnn=1-8192

Word

Analog Outputs

%AQnnnn

nnnn=1-8192

Word

** 50 Words

Block

Discrete Inputs

%Innnnn

nnnnn=1-12288

1 16 +1

Discrete Outputs

%Qnnnnn

nnnnn=1-12288

1 16 +1

Discrete Temporaries

%Tnnn

nnn=1-256

1 16 +1

Discrete Internals

%Mnnnnn

nnnnn=1-12288

1 16 +1

%SA Discretes

%SAnnn

nnn=1-128

1 16 +1

%SB Discretes

%SBnnn

nnn=1-128

1 16 +1

%SC Discretes

%SCnnn

nnn=1-128

1 16 +1

%S Discretes

%Snnn

nnn=1-128

1 16 +1

Genius Global Data

%Gnnnn

nnnn=1-7680

1 16 +1

** 800 Bits

P-16

PWS WORKSTATION

PLC PWS

2.:
a.PWS RS232 of PLC miniconverter kit

b. PWS RS422 of

PLC 9030 CPU port

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

RS422 CPU PORT


RS232C

19200/9600 bps
8-bit;none,1-bit

e.P.L.C. ID
f. P.L.C. password

blanks
none or ********

PWS WORKSTATION

COM2=RS232/422/485
1. RS422SW10=OFF

00000000 or ********

Hitech Electronics Corp.

P-17

PB13=Hitachi EC PLC PWS-


1.ADP3 PLC

Internal Register
Internal Register
Internal Register
Timer/Counter Register
Timer/Counter Register

WMnnn
WMnnn
WMnnn
TCnnn
TCnnn

nnn=400, 402, 404, , 654


nnn=700, 702, 704, , 954
nnn=960, 962, 964, , 990
nnn=100-195
nnn=200-295

Word
Word
Word
Word
Word

** 60Words

Input Relay

Xnnn

Output Relay

Ynnn

Auxiliary Relay
Timer/Counter Relay

Mnnn
TCnn

nnn=0-15, 20-35, 40-55, 60-75, ,


180-195
nnn=200-215, 220-235, 240-255, ,
380-395
nnn=400-655, 700-955, 960-991
nn=0-95

Block
X0,X20,X40
Y200,Y220
M400,M420
TC0,TC1TC80

2.:PWS- to PLC Program Console Port

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.

RS232C

9600 bps

COM1 or COM2 ==> RS232

1. ADP3
SW5=OFF
d.
2. PWS-
7-bit ,EVEN, 1- bit
e. CTS Handshanking
Enabled
SW5=ON
Set the PLC's peripheral mode selector switch at the position of COM2 to select the exclusive
protocol.

P-18

PWS WORKSTATION

PLC PWS

PE53=IDEC MICRO-3 PLC PWS-


1.ADP3 PLC

Input Relay
Output Relay
Internal Relay
Shift Register
Timer Preset
Timer Current
Counter Preset
Counter Current
Data Register
Calender/Clock

Xn
Yn
Mnn
Rnn
TPnn
Tnn
CPnn
Cnn
Dnn
Wn

n=0-3
n=0-3
nn=0-31
nn=0-48; 0 8
nn=0-31(read only)
nn=0-31
nn=0-31(read only)
nn=0-31
nn=0-99
n=0-6

Byte
Byte
Byte
Bit
Word
Word
Word
Word
Word
Word

** 50 Words
**Timer Preset and Counter Preset are read only. If the value of a TP or CP is in a data
register, then the value read is the address of that data register.

Input Relay
Output Relay
Internal Relay
Shift Register
Timer Status
Counter Status

Xnb
Ynb
Mnnb
Rnn
Tnn
Cnn

n=0-3; b=0-7
n=0-3; b=0-7
nn=0-31; b=0-7
nn=0-63
nn=0-31 read only
nn=0-31 read only

Block
b=0 . X10
b=0 . Y00
b=0 . M10
0 8
0 8
0 8

** 800 bits
2.:PWS-to PLC PROGRAM Loader RS485 PORT(MICRO3-CPU PORT)

3.: PWS PLC


A. P.L.C.
B. PWS-
COM2=RS232/422/485
RS485
a./
b.(STATION No).

0-31255

c.
d.
e.CTS Handshaking

9600bps
7-bit;EVEN; 1-bit
Disabled

1. RS485SW10=ON
1. ADP3
PLC255(PLC)

If your application has only one PLC, then set the parameter to 255; otherwise, set it to the PLC's
"PLC Address for Network Communication" that you set with the program loader
PWS WORKSTATION

Hitech Electronics Corp.

P-19

PK53=JETTER NANO_B PLC PWS-


1.ADP3 PLC

User Register
User Register

Input Relay
Out[ut Relay
Flag Relay

Rnnnn
WRnnnn

nnnn=0-32767
nnnn=0-32767

Inn
Onn
Fnnn

nn=11-58
nn=11-58
nnn=0-255

DWord(32Bit)
Word(16Bit)

2.:
a.PWS- to PLC RS232 PORT (15-pin male)

b.PWS- to PLC RS232 PORT (9-pin male)

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-20

RS232C

9600 bps
8-bit, EVEN , 1-bit

COM1 or COM2=RS232

PWS WORKSTATION

PLC PWS

PK63=JETTER DELTA PLC PWS-


1.ADP3 PLC

User Register
User Register

Input Relay
Out[ut Relay
Flag Relay

Rnnnn
WRnnnn

Inn
Onn
Fnnn

nnnn=0-64999
nnnn=0-64999

DWord(32Bit)
Word(16Bit)

nnn=101-864
nnn=101-864
nnn=0-2047

2.:
a.PWS- to PLC RS232 PORT (15-pin male)

b.PWS- to PLC RS232 PORT (9-pin male)

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

PWS WORKSTATION

RS232C

9600 bps
8-bit, EVEN , 1-bit

COM1 or COM2=RS232

Hitech Electronics Corp.

P-21

PK03=Klockner Moeller PS
1.ADP3 PLC

Word Marker

MWnnnnn

nnnnn=0-32766

Word

** 32Words

Bit Marker0

Block

Mnnnnn.b

nnnnn=0-32766b=0-7

b=0 . M10.0

** 512 bits

2.:PWS- to PLC RS232 Programming PORT CPU ZB4-303-KB1

3.: PWS PLC


A. P.L.C.
B. PWS-
COM1or COM2=RS232
RS232
a./
0=PS4-201
b.(STATION No).
1. ADP3
1=PS316
PLC0/1(PLC)
9600bps
c.
1. ADP3
SW5=OFF
1. 8-bit
d.
2.Parity
None
2. PWS-
3. 1-bit
SW5=ON

P-22

PWS WORKSTATION

PLC PWS

PC0=KOYO SA PLC PWS


1.ADP3 PLC

TMR/CTR Accumulater
Register Values

nnn
mmm

nnn=octal number 600-677


mmm=octal number 400-576;
mmm must be a multiple of 2

Word
Bytes

Block

0
Input/Output Bits
Bnnn
nnn=octal number 0-157
0
Input/Output Bits
Bnnn
nnn=octal number 700-767
0
Internal Relay Bits
Bnnn
nnn=octal number 160-377
0
Shift Register Bits
Bnnn
nnn=octal number 400-577
0
TMR/CTR Bits
Bnnn
nnn=octal number 600-677
When the Workstation changes a relay, it reads a byte from the PLC that contains 8 relays,
changes the desired bit, and writes the byte to the PLC. These steps require more than one PLC
scan to complete, so your PLC ladder program must not control other bits within the same byte. If it
does, there is a risk that the Workstation will reverse a change that the PLC makes.
For example, if the Workstation changes B3, it reads B0 through B7 as a single byte, changes B3
within that byte, and writes that entire byte back to the PLC. If your PLC ladder changes some other
relay within that byte in the meantime, then the Workstation's subsequent write will cancel that
change.

2.:PWS- to PLC RS232C PORT of SA21

## KOYO SA21 E02-DM TI305-02DM


3.: PWS PLC
A. P.L.C.
B. PWS-
a./
RS422RS232C
COM2=RS232/422/485
b.(STATION No).

c.
9600/19200 bps
d.
8-bit, odd, 1-bit
e.Operation Mode
RUN Mode
e.Comm. Mode
ASCII mode.sw2-8=ON
PWS WORKSTATION

Hitech Electronics Corp.

P-23

P913=KOYO DIRECT DL PLC PWS-


1.ADP3 PLC

Timer Accumulated
Counter Accumulated
V Memory
Link Relays
Input Status
Output Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2

Input Status
Outpuut Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2

Vnnn
Vnnnn
Vnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn

nnn=octal number 0-177


nnnn=octal number 1000-1177
nnnn=octal number 1400-7777
nnnnn=octal number40000-40037
nnnnn=octal number40400-40423
nnnnn=octal number40500-40523
nnnnn=octal number40600-40635
nnnnn=octal number41000-41027
nnnnn=octal number41100-41107
nnnnn=octal number41140-41147
nnnnn=octal number41200-41205
nnnnn=octal number41216-41230

Xnnn
Ynnn
Cnnn
Snnn
Tnnn
CTnnn
SPnnn
SPnnn

nnn=octal number 0-477


nnn=octal number 0-477
nnn=octal number 0-737
nnn=octal number 0-577
nnn=octal number 0-177
nnn=octal number 0-177
nnn=octal number 0-137
nnn=octal number 320-617

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Block
0
0
0
0
0
0
0
0

2.:PWS to PLC RS232C PORT


a. PWS to PLC RS232C PORT
b. PWS to PLC (cpu240) RS232C PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
COM2=RS232/422/485
RS232C
a./
01
b.(STATION No).
9600 bps
c.
1. 8-bit
d.
2.Parity ;ODD
3. 1-bit
e.Comm. Protocol Mode
HEX. (TISOFT AUX26)

P-24

PWS WORKSTATION

PLC PWS

PL03= LG K10/60H/200H PWS-


1.ADP3 PLC

Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Current Value
Counter Current Value
Timer Set Value
Counter Set Value
Data Register

Mnn
Pnn
Knn
Lnn
Fnn
Tnnn
Cnnn
TSnnn
CSnnn
Dnnnn

nn=0-63
nn=0-15
nn=0-31
nn=0-31
nn=0-15
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
nnnn=0-1023

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word

** 32 Words

Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Relay
Counter Relay

Mnnb
Pnnb
Knnb
Lnnb
Fnnb
Tnnn
Cnnn

nn=0-63; b=hex number0-f


nn=0-15; b=hex number0-f
nn=0-31; b=hex number0-f
nn=0-31; b=hex number0-f
nn=0-15; b=hex number0-f
nnn=0-255
nnn=0-255

Block
b=0
b=0
b=0
b=0
b=0
0 16
0 16

2.:PWS- to the RS-232 Port of K200H CPU

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.

RS232C
00
9600 bps

d.

8-bit,NONE,1-bit

PWS WORKSTATION

COM1/COM2=RS232
1. ADP3
SW5=OFF
2. PWS-
SW5=ON

Hitech Electronics Corp.

P-25

PL53=LG K300S PLC PWS-


1.ADP3 PLC

I/O Relay
AUX Relay
Keep Relay
Link Relay
Special Relay
Timer
Counter
Step controller
Data Register

PWnn
MWnnn
KWnn
LWnn
FWnn
TWnnn
CWnnn
SWnnnn
DWnnnn

nn= 0-31
nnn = 0-191
nn = 0-31
nn = 0-63
nn = 0-63
nnn = 0-255
nnn = 0-255
nnnn = 0-9999
nnnn = 0-9999


I/O Relay
AUX Relay
Keep Relay
Link Relay
Special Relay

PWnnb
MWnnnb
KWnnb
LWnnb
FWnnb

nn= 0-31
b=0-f
nnn = 0-191 b=0-f
nn = 0-31
b=0-f
nn = 0-63
b=0-f
nn = 0-63
b=0-f

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)

Block

2.:
PWS- to PLC RS232 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./

RS232C

b.(STATION No). RS232C=0


c.
RS232C=9600 bps
d.
RS232C =8 bit,none,1 bit

P-26

PWS WORKSTATION

PLC PWS

PL23= LG K500H/1000H PWS-


1.ADP3 PLC

Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Current Value
Counter Current Value
Data Register

Mnnn
Pnn
Knn
Lnn
Fnn
Tnnn
Cnnn
Dnnnn

nnn=0-191
nn=0-63
nn=0-31
nn=0-63
nn=0-31
nnn=0-255
nnn=0-255
nnnn=0-9999

Word
Word
Word
Word
Word
Word
Word
Word

** 32 Words

Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay

Mnnnb
Pnnb
Knnb
Lnnb
Fnnb

nnn=0-191;b=hex number 0-f


nn=0-63; b=hex number 0-f
nn=0-31; b=hex number 0-f
nn=0-63; b=hex number 0-f
nn=0-31; b=hex number 0-f

Block
b=0
b=0
b=0
b=0
b=0

2.:
a.PW S to RS232 of PLC-K1000H CPU ;

b.PW S to RS485 of PLC-K1000H CPU

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
sw1=Off
sw1=on
b.(STATION No).
c.
d.
PWS WORKSTATION

RS422RS232C
RS422
RS232
00(CPU PORT)
00--15(RS422)
9600/19200 bps
8-bit,NONE,1-bit

COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLC00(PLC)

Hitech Electronics Corp.

P-27

PL43=LIYAN CX PLC PWS-


1.ADP3 PLC

Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Data
Special Data
Timer Preset Register
Counter Preset Register
Timer Current Register
Counter Current Register
Timer Preset Register
Counter Preset Register
Timer Current Register
Counter Current Register

Xnnn
Ynnn
Mnnnn
Snnn
Dnnnn
Dnnnn
PTnnn
PCnnn
CTnnn
CCnnn
PTnnn
PCnnn
CTnnn
CCnnn

nnn= 0-076
nnn= 0-076
nnnn=0-8254
nnn= 0-510
nnn= 0-511
nnnn=8000-8255
nnn= 0-063
nnn= 0-063
nnn= 0-063
nnn= 0-063
nnn= 224-255
nnn= 224-255
nnn= 224-255
nnn= 224-255

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)


Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Data
Special Data
Timer Relay Status
Counter Relay Status

Xnnnb
Ynnnb
Mnnnnb
Snnnb
Dnnnb
Dnnnnb
Tnnnb
Cnnnb

nnn= 0-077 ; b=0-7


nnn= 0-077 ; b=0-7
nnnn=0-8255; b=0-7
nnn= 0-511 ; b=0-7
nnn= 0-511 ; b=0-7
nnnn=8000-8255;b=0-7
nnn= 0-063 ; b=0-7
nnn= 0-063 ; b=0-7

Block
b=0 . X200
b=0 . Y200
b=0 . M200

2.:
a.PWS- to PLC RS232 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-

P-28

a./

RS232C

b.(STATION No).
c.
d.

9600 bps
8-bit, EVEN , 1-bit

COM1 or COM2=RS232

PWS WORKSTATION

PLC PWS

P603= MATSUSHITA FP PLC PWS-


1.ADP3 PLC

Internal Relay
Special Internal
Relay
Link Relay
External Input
Relay
External Output
Relay
Timer/Counter
P.V.
Timer/Counter
S.V.
Data Register
Special Data
Register
Link
Data
Register
File Register

Block read

WRnn
WRnnn

nn=0-97(875)
nnn=900-910

Device Type /
Aux. Address
0
0
1
0

WLnnn
WXnnn

nnn=0-127(639)
nnn=0-127(255)

2
3

0
0

Word
Word

WYnnn

nnn=0-127(255)

Word

EVnnn

nnn=0-255(2047)

Word

SVnnn

nnn=0-255 (2047)

Word

DTnnnn
DTnnnn

nnnn=0-2047 (10239)
nnnn=9000-9255

7
8

0
0

Word
Word

LDnnn

nnn=0-127(8447)

Word

FLnnnnn

nnnn=0-8191 (32764)**

10

Word

R/W
Word
Word

** 27 Words
**The Register setting range of FP10SH is nnnnn=0- 32764.

Internal Relay
Special Internal Relay
Link Relay
External Input Relay
External Output Relay
Timer Flag Contact
Counter Flag Contact

Rnnnb
Rnnnb
Lnnnb
Xnnnb
Ynnnb
Tnnn
Cnnn

nn=0-97(875);b= 0-f
nnn=900-910;b= 0-f
nnn=0-127(639);b=0-f
nnn=0-127(255);b=0-f
nnn=0-127(255);b=0-f
nnn=0-255(2047)
nnn=0-255(2047)

Block
b=0 . R1230
b=0 . R9100
b=0 . L110
b=0 . X00
b=0 . Y00
0 16
0 16

** 432 Bits
**The Relay setting range of FP10SH is nnnn=0-2047
2.:
a.PWS- to PLC RS232C LINK of

PWS WORKSTATION

FP3 CCU FP1 LINK PORT

Hitech Electronics Corp.

P-29

b.PWS- to PLC

RS422

of

PROGRAM PORT ( FP3 CPU PORT)

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).

c.
d.

P-30

RS422RS232C
01-32
FP CPU PORT =238
FP1computer link
19200/9600 bps
FP10SH -CPU115.2K bps
8-bit,odd, 1-bit

COM2=RS232/422/485
1. ADP3
PLC01(PLC)
CPU PORT238
1. ADP3
SW5=OFF
2. PWS-
SW5=ON

PWS WORKSTATION

PLC PWS

P103.tsk=Mirle DX PLC PWS


1.ADP3 PLC

**DM area
DM area

DMnnnn
DMnnnn

nnnn=0-575
nnnn=0-287

Word(32bits)
Word(16bits)

DM=0-47
DM=0-23

** MIRLE DX 32BITS 1DX =2DM (:400=DM64,DM65)



Input
Output
Internal Relay

IRnnn
IRnnn
IRnnnn

nnn=0-15,100-115
nnn=400-515
nn=800-1315

IR=6-15,100-115

IR=1200-1307

2.:
a.PWS to MIRLE DX RS422 PORT

b.PWS to MIRLE SBC 20 RS422 PORT

c.PWS to MIRLE NDX RS232

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).

RS232C/ RS422
0

c.

9600 bps

d.

1.DX,SBC208 bit,ODD,1 stop bit 2. PWS-


8 bit,NONE,1 stop bit SW5=ON
2.NDX

PWS WORKSTATION

Hitech Electronics Corp.

COM2=RS232/422
1. ADP3
PLC00

P-31

P703=Mitsubishi FX-PLC PWS-


1.ADP3 PLC

Auxiliary Relay
Special Auxiliary Relay
Status Relay
Input Relay
Output Relay
Timer PV
16-bit Counter PV
32-bit Counter PV
Data Register
Special Data Register

Mnnnn
Mnnnn
Snnn
Xnnn
Ynnn
Tnnn
Cnnn
Cnnn
Dnnn
Dnnnn

nnnn=0-3071; 0 8
nnnn=8000-8255; 0 8
nnn=0-999; 0 8
nnn=octal number 0-377; 0
nnn=octal number 0-377; 0
nnn=0-255
nnn=0-199
nnn=200-255
nnn=0-1023(7999) D1000=FILE REGISTER
nnnn=8000-8255

Word
Word
Word
Word
Word
Word
Word
DWord
Word
Word

** 32 Words

Auxiliary Relay
Special Auxiliary Relay
Status Relay
Input Relay
Output Relay
Timer Flag
Counter Flag

Mnnnn
Mnnnn
Snnn
Xnnn
Ynnn
Tnnn
Cnnn

0-3071
8000-8255
0-999
Octal number 0-377
Octal number 0-377
0-255
0-255

Block
0 8
0 8
0 8
0
0
0 8
0 8

** 512 bits
2.:
a. PWS to RS422 of PLC-FX2 CPU

P-32

PWS WORKSTATION

PLC PWS

b. PWS- to PLC PROGRAM Loader PORT (Mitsubishi FX2n/FX0n CPU PORT)

3.: PWS PLC


A. P.L.C.
B. PWS-
RS422
a./
9600 bps
b.
7-bit,EVEN,1-bit
c.

PWS WORKSTATION

Hitech Electronics Corp.

P-33

P8n3=Mitsubishi A PLC PWS-


1.ADP3 PLC

Input Relay
Output Relay
Link Relay
Internal Relay
Special Relay
Latch Relay
Annunciator
Timer PV
Counter PV
Data Register
Special Register
File Register
Link Register

Xnnn
Ynnn
Bnnn
Mnnnn
Mnnnn
Lnnnn
Fnnnn
TNnnn
CNnnn
Dnnnn
Dnnnn
Rnnnn
Wnnn

nnn=hex number 0-7ff; 0


nnn=hex number 0-7ff; 0
nnn=hex number 0-fff; 0
nnnn=0-8191; 0 16
nnnn=9000-9255; 16
nnnn=0-2047; 0 16
nnnn=0-2047; 0 16
nnn=0-999
nnn=0-999
nnnn=0-6143
nnnn=9000-9255
nnnn=0-8191
nnn=hex number 0-fff

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word

** 64 Words

Input Relay
Output Relay
Link Relay
Internal Relay
Special Relay
Latch Relay
Annunciator
Timer Contact
Timer Coil
Counter Contact
Counter Coil

Xnnn
Ynnn
Bnnn
Mnnnn
Mnnnn
Lnnnn
Fnnnn
TSnnn
TCnnn
CSnnn
CCnnn

hex number 0-7ff


hex number 0-7ff
hex number 0-fff
0-8191
9000-9255
0-2047
0-2047
0-999
0-999
0-999
0-999

Block
0
0
0
0 16
3 16
0 16
0 16
0 16
0 16
0 16
0 16

** 512 bits
2.: a.PWS PLC

P-34

AJ71UC24-R2/S8

PWS WORKSTATION

PLC PWS

b.PWS PLC AJ71UC24

RS422

c, PWS PLC AnA AnA/AnS/AnU CPU port RS422

3.: PWS PLC

A. P.L.C.
a./
AJ71UC24 sw1=ON
sw1=Off
b.(STATION No).

c.
d.
e.Comm. Protocol
f.Check Sum
g.Write during Run

B. PWS-

RS422RS232C
RS422
RS232
00(CPU PORT)
00(AISJ71C24-S3)
00-31(AJ71UC24)
9600/19200 bps
CPU PORT=9600bps
8-bit,ODD,1-bit
Format 1;5;A
YES
Allowed

COM2=RS232/422/485
1. RS422SW10=OFF
1. ADP3
PLC00(PLC)
255
PWS

Set the address of the Workstation as 255 and the address of the PLC as 0 when an A1SJ71C24 or
AJ71C24 is used for the communications.
To connect the Workstation to the PLC CPU port, set the Workstation communication parameters
according to the following; set the DIP switch No.10 to off when COM2 is used.
Baud Rate = 9600; Data Format = (8 data bits, odd parity, 1 stop bit)

PWS WORKSTATION

Hitech Electronics Corp.

P-35

P303=Modicon PC984
P313=Modicon TSX Quantum
1.ADP3 PLC

Input Registers
nnnnn
nnnnn=30001-39999
Output Registers
nnnnn
nnnnn=40001-49999
Input Registers(TSX Quantum)
nnnnnn
nnnnn=300001-365535
Output Registers(TSX Quantum)
nnnnnn
nnnnn=400001-565535
** 125 Words

Word
Word
Word
Word

Discrete Outputs
nnnnn
nnnnn=1-9999
Discrete Inputs
nnnnn
nnnnn=10001-19999
Discrete Outputs(TSX Quantum) nnnnn
nnnnn=000001-065535
Discrete Inputs (TSX Quantum) nnnnn
nnnnn=100001-165535
** 2000 Bits
2.: PWS to RS232 of PLC CPU port

3.: PWS PLC


A. P.L.C.
B. PWS-
COM1/COM2=RS232
RS232C
a./
1. ADP3
1
b.(STATION No).
PLC01(PLC)
01247 (mem setup)
19200/9600 bps
c.
8, EVEN ,1
d.
(7,O,1);(7,E,1);(7,E,2)
RTU MODE
(8,E,1);(8,O,1);(8,N,1)

P-36

PWS WORKSTATION

PLC PWS

P103=OMRON C PLC PWS


1.ADP3 PLC

IR area
HR area
AR area
LR area
TC area
DM area

IRnnn
HRnn
ARnn
LRnn
TCnnn
DMnnnn


IR area
HR area
AR area
LR area
TC area

IRnnnbb
HRnnbb
ARnnbb
LRnnbb
TCnnn

Block read

nnn=0-255
nn=0-99
nn=0-27
nn=0-63
nnn=0-511
nnnn=0-6655

Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)

nnn=0-255; bb=00-15
nn=0-99 ; bb=00-15
nn=0-27 ; bb=00-15
nn=0-63 ; bb=00-15
nnn=0-511

Block
bb=00 . IR12300
bb=00 . HR2300
bb=00 . AR100
bb=00 . LR2300
16 . TC16

Max. 28
Max. 28
Max. 28
Max. 28
Max. 28
Max. 28

2.:
a.PWS- to PLC RS232C HOST LINK of

LK201/ C200HS/C28H/C40H/CQM1

b.PWS- to PLC

C200H-LK202

RS422 HOST LINK of

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
1.CQM1-CPU21
c.
1.CQM1-CPU21
d.
e.Operation Mode
f. PROTOCOL
PWS WORKSTATION

RS232C/ RS422/ RS485


00(00-31)
DM6648=0000
19200/9600 bps
DIP-sw5=OFF ()
7-bit, ENEN, 2
Monitor Mode
Multiple-Link

COM2=RS232/422/485
1. ADP3
PLC00(PLC)

Hitech Electronics Corp.

P-37

PS03=SAIA PCD1 PLC PWS-


1.ADP3 PLC

Timer
Counter
Register

Input
Output
Flag

Tnnnn
Cnnnn
Rnnnn

nnnn=0-1599
nnnn=0-1599
nnnn=0-4095

Innn
Onnn
Fnnnn

nnn=0-255
nnn=0-255
nnn=0-8191

DWord(32Bit)
DWord(32Bit)
DWord(32Bit)

2.:
a. PWS- to PLC RS232 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-38

RS232C

9600 bps
8-bit, None , 1-bit

COM1 or COM2=RS232

PWS WORKSTATION

PLC PWS

PN13=SIDE MIDA 20/20D PLC PWS-


1.ADP3 PLC

Register

Wnnnn

nnnn= 0-1599


I/O Relay

Bnnn

nnn= 0-999

Word(16Bit)

Block

2.:
a.PWS- to PLC RS232 PORT

b.PWS- to PLC RS485 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./

RS232C
RS485
b.(STATION No). RS232C=153
RS485=1
c.
RS232C=9600 bps
RS485 =9600 bps
d.
RS232C =7 bit,none,1 bit
RS485 =8 bit,even,1 bit
e.
RS232C=stop mode
RS485 =running mode

PWS WORKSTATION

RS232C:SIDE MIDA 20/20D


RS485 :MODBUS SLAVE
RS232C=153
RS485 =1

Hitech Electronics Corp.

P-39

P203=Siemens S5 PLC PWS-


1.ADP3 PLC

Input Image
Output Image
Extended I/O
Flag Bits
Peripheral I/O
System Data Area
System Data Area
System Data Area
System Data Area
Timer Current
Counter Current
Data Block

IBnnn
QBnnn
OBnnn
FBnnn
PBnnn
RSnnn
RInnn
RJnnn
RTnnn
Tnnn
Cnnn
DBmmm/nnn
DBnnn

Data Block

DWmmm/nnn
DWnnn

nnn=0-127
Byte
Max. 30
nnn=0-127
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
Max. 30
mmm=0-255; mmm is Block number
nnn=0-255; nnn is the numbers which
defines block. If the mmm not set the
numbers, the numbers of mmm is 3= DB3/nnn
Max. 30
mmm=0-127; mmm is Block number
nnn=0-255; nnn is the numbers which
defines block. If the mmm not set the
numbers, the numbers of mmm is 3= DW3/nnn

** 30 Words

Input Image
Output Image
Extended I/O
Flag Bits
Peripheral I/O

IBnnn.b
QBnnn.b
OBnnn.b
FBnnn.b
PBnnn.b

nnn=0-127; b=0-7
nnn=0-127; b=0-7
nnn=0-255; b=0-7
nnn=0-255; b=0-7
nnn=0-255; b=0-7

Block
b=0 . IB30.0
b=0 . QB2.0
b=0 . OB0.0
b=0 . FB23.0
b=0 . PB23.0

2.: RS-232/Current-loop converter .


PWS-30XX(OLD MODEL) 20mA current-loop . PWS-12xx,
PWS-17xx,PWS-700, PWS-31xx and PWS-37XX 20mA current-loop .

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
20mA CURRENT LOOP
PWS-30xx/PWS-21xx
b.(STATION No).
c.
d.
e.PLC Mode Code
e Command Delay

P-40

RS-232/Current-loop converter

9600 bps
8-bit, EVEN ,1-bit
PLCData Block
n=3255 OPEN

COM1 or COM2=>RS232
PLC. MODE CODE
0: 90U
1: 95U
2:100U
3:102U 4:103U
5:115U
6:135U/921
7:135U/922 8:135U/928
PWS Command Delay

PWS WORKSTATION

PLC PWS

P253=Siemens S7-200 PPI PWS-


1.ADP3 PLC

Input Image
Input Image
Output Image
Output Image
Internal Bits
Internal Bits
Timer
Counter
Special S
Special S
Special Bits
Special Bits
Special Bits
Analog input word
Analogoutputword
Data Area
Data Area

IWn
IDn
QWn
QDn
MWnn
MDnn
Tnnn
Cnnn
SWnn
SDnn
SMWnnn
SMWnnn
SMDnnn
AIWnn
AQWnn
VWnnnn
VDnnnn

n=0-6
n=0-4
n=0-6
n=0-4
nn=0-30
nn=0-28
nnn=0-255
nnn=0-255
nn=0-30
nn=0-28
nnn=0-27
nnn=28-192
nnn=0-190
nn=0-30
nn=0-30
nnnn=0-5118
nnnn=0-5116

Word
Double Word
Word
Double Word
Word
Double Word
Word
Word
Word
Double Word
Word* read only
Word
Double Word
Word* read only
Word* read only
Word
Double Word

n=0-7; b=0-7
n=0-7; b=0-7
nn=0-31;b=0-7
nnn=0-255
nnn=0-255
nnn=0-193 ;b=0-7
nnnn=0-5119 ;b=0-7
nn=0-31; b=0-7

Block
b=0 . I3.0
b=0 . Q2.0
b=0 . M0.0
b=0 .T0 *read only
b=0 .C0 *read only
b=0 . SM23.0
b=0 . V2323.0
b=0 . S25.0

**AQW; SW;SD cant used in CPU212,214



Input Image
Output Image
Internal Bit
Timer Bit
Counter Bit
Special Bit
Data Area Bit
Special M

In.b
Qn.b
Mnn.b
Tnnn
Cnnn
SMnnn.b
Vnnnn.b
Snn.b

2.:PWS- to PLC PROGRAM

PORT of (RS485 mode)

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.
e Command Delay
PWS WORKSTATION

RS485
02(01-32)
9600 /19200bps
8-bit, EVEN, 1-bit

COM2=RS232/422/485
1. RS485SW10=ON

PWS Command Delay

Hitech Electronics Corp.

P-41

P263=Siemens S7-300 CP340 PWS-


1.ADP3 PLC

DBmmm.DBWnnnn

mmm=1-255
nnnn=0-8190

DBmmm.DBDnnnn

mmm=1-255
nnnn=0-8188

DBmmm.DBWnnnn is the address of a


word locates at byte #nnnn and the
byte following #nnnn of data block #3
DBmmm.DBDnnnn is the address of a
double-word locates at byte #nnnn and
the three bytes following #nnnn of data
block #mmm

Word
Double
Word

** 32 Words

DBmmm.DBXnnnn.b

mmm=1-255
nnnn=0-8190
b=0-7

Block

DBmmm.DBXnnnn.b is the address of bit #b of the


word locates at byte #nnnn of data block #mmm

2.:a.PWS- to PLC CP340 RS232C PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./

P-42

b.(STATION No).
c.

RS232=CP340
RS422=CP340
RS485=CP340

9600 /19200bps

d.

8-bit, EVEN, 1-bit

e.FUNCTION BLOCK

FB40,FB2,FB3,DB2,DB3 for CP

COM2=RS232/RS422/RS485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
SW5=OFF
2. PWS-
SW5=ON

PWS WORKSTATION

PLC PWS

P273=Siemens S7-300 MPI-Cable PWS-


1.ADP3 PLC

Device Type /
Aux. Address

Input Image
Input Image
Output Image
Output Image
Bits
Bits
Data Area
(DB10)
Data Area
(DB10)
Data Area
(DB10)

IWnnnnn
IDnnnnn
QWnnnnn
QDnnnnn
MWnnn
MDnnn
VWnnnnn

nnnnn=0-65534
nnnnn=0-65532
nnnnn=0-65534
nnnnn=0-65532
nnnnn=0-254
nnnnn=0-252
nnnnn=0-65534

0
1
2
3
4
5
6

0
0
0
0
0
0
0

Word
DWord
Word
DWord
Word
DWord
Word

R/W
9
9
9
9
9
9
9

VDnnnnn

nnnnn=0-65532

DWord

DBWnnnnn

Word

Data Area
(DB10)

DBDnnnnn

DWord

Data Area

DBmmm.DBW
nnnnn
DBmmm.DBD
nnnnn

nnnnn=0-65534; the Byte


nnnnn & nnnnn+1 make
DBWnnnnn
nnnnn=0-65532; a double
word address, the
DBWnnnn & DBWnnnn+1
make DBDnnnn
mmm=1-255
nnnnn=0-65534
mmm=1-255
nnnnn=0-65532

Word

DWord

Data Area


Input Image
Output Image
Bit
Data Area Bit
(=DB10)
Data Area Bit
(=DB10)

Data Area Bit

Device Type /
Aux. Address

Innnnn.b
Qnnnnn.b
Mnnn.b
Vnnnnn.b

nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
nnn=0-255; b=0-7
nnnn=0-65535; b=0-7

0xC0
0xC1
0xC2
0xC3

0-7
0-7
0-7
0-7

Block
R/W
9
Bit
9
Bit
9
Bit
9
Bit

DBXnnnn.b

nnnnn=0-65535; b=0-7

0xC4

0-7

Bit

0xC5

0-7

Bit

DB10.DBXnnnnn.b is a bit address, It is in


#b bit of #nnnnn word with DB10
DBmm.DBXnn mm=1-31
nn.b
nnnnn=0-65535; b=0-7

2.:
a.PWS- to PLC MPI CABLE RS232C PORT MPI 6ES7-972-0CA21-0XA0

PWS WORKSTATION

Hitech Electronics Corp.

P-43

b.PWS- to PLC MPI CABLE RS232C PORT HMI 6ES7-972-0CA10-0XA0

c. Exam ple of the connections between PW S & S7-300/400 CPU MPI port:

3.: PWS PLC


A. P.L.C.
B. PWS-

P-44

a./
b.(STATION No).

MPI CABLE RS232


02

c.

19200/38400 bps

d.

8-bit, ODD, 1-bit

e. Command Delay
f. DATA BLOCK

DB10 for S7-300-CPU

COM1 or COM2=RS232
1. ADP3
PLC=02
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS Command Delay

PWS WORKSTATION

PLC PWS

P277=Siemens S7-300 HMI-Cable PWS-


1.ADP3 PLC

Input Image
Input Image
Output Image
Output Image
Bits
Bits
Timer Image
Timer Image
Timer Image
Timer Image
Counter Image
DBmmm.DBWnnnnn

IWnnnnn
IDnnnnn
QWnnnnn
QDnnnnn
MWnnn
MDnnn
Tnnnnn.10ms
Tnnnnn.100ms
Tnnnnn.1s
Tnnnnn.10s
Cnnnnn
mmm=1-255
nnnn=0-65534

DBmmm.DBDnnnnn

mmm=1-255
nnnn=0-65532

Data Area (DB10)

DBWnnnnn

Data Area (DB10)

DBDnnnnn

Data Area (DB10)

VWnnnnn

Data Area (DB10)

VDnnnnnn


Input Image
Output Image
Bit
Data Area Bit

Innnnn.b
Qnnnnn.b
Mnnnnn.b
DBmm.DBXnnnnn.b

Data Area Bit


(=DB10)
Data Area Bit
(=DB10)

DBXnnnnn.b

PWS WORKSTATION

nnnnn=0-65534 length=1-1023
nnnnn=0-65532 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65532 length=1-1023
nnnnn=0-65534 length=1-128
nnnnn=0-65532 length=1-128
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnn=0-65534; DBWnnnn is a word
address, the Byte nnnn & nnnn+1
make DBWnnnn
nnnnn=0-65532;DBDnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn
nnnnn=0-65534; DBWnnnnn is a
word address, the Byte nnnnn &
nnnnn+1 make DBWnnnnn
nnnnn=0-65532; DBDnnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn
nnnnn=0-65534; VWnnnnn is a word
address, the Byte nnnnn & nnnnn+1
make DBWnnnnn
nnnnn=0-65532; VDnnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn

nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
mmm=1-31
nnnnn=0-65535 ;b=0-7
nnnnn=0-65535 ;b=0-7

Vnnnnn.b
nnnnn=0-65535; b=0-7
DB10.DBXnnnnn.b is a bit address, It is in #b bit
of #nnnnn word with DB10

Hitech Electronics Corp.

Word
Double Word
Word
Double Word
Word
Double Word
Word
Word
Word
Word
Word
Word
Double Word
Word
Double Word
Word
Double Word

Block
b=0 . I3.0
b=0 . Q2.0
b=0 . M0.0
b=0 . DB22.DBX20.0
b=0 . DBX23.0
DBX23.0=DB10.DBX23.0
b=0 . V23.0
V23.0=DB10.DBX23.0

P-45

2.: PWS HMI 6ES7-972-0CA10-0XA0 RS232

3.: PWS PLC


A. P.L.C.
B. PWS-
a.Communication Format
b.Node Address
c.Transmission Speed
d.Transmission Format
e. OPEN DATA BLOCK

P-46

:HMI CABLE RS232


:02
:9600/19200/38400 bps
:8-bit, ODD, 1-bit
:DB block for S7-300-CPU

COM2=RS232
PWS Command Delay Setting

PWS WORKSTATION

PLC PWS

PY13=TAIAN TP02 PLC PWS-


1.ADP3 PLC

Input
Output
Auxiliary Register
Auxiliary Register
System Register
Auxiliary Relay Register
Constant Register

Input
Output
Auxiliary Relay
Special Relay

Xnnn
Ynnn
Vnnnn
Dnnnn
WSnnn
Cnnnn
WCnnn

nnn=1-369( 1 16+1 )
nnn=1-369( 1 16+1 )
nnnn=1-1024
nnnn=1-2048
nnn=1-128
nnnn=1-2033( 1 16+1 )
nnn=1-912

Xnnn
Ynnn
Cnnnn
SCnnn

nnn=1-384
nnn=1-384
nnnn=1-2048
nnn=1-128

Word
Word
Word
Word
Word
Word
Word

2.:
a.PWS- to PLC RS422 PORT of TP02

b.PWS- to PLC RS485 PORT of TP02

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).

RS422/485
01

c.
d.

19200 bps
7-bit, EVEN , 2-bit

1. ADP3
PLC=01

[] A. P.L.C. ADP3 , PLC


WS041,WS042,WS044,WS045
WS041---SET RS422 BAUD RATE,DATA BIT,PARRITY,STOP BIT
WS042---SET RS422 STATION NUMBER
WS044---SET RS485 BAUD RATE,DATA BIT,PARRITY,STOP BIT
WS045---SET RS485 STATION NUMBER

TP02 PLC RS422 Port (01)


WS042 01()
(19200 bps)(7bit,EVEN,2bit) WS041 0120()

PWS WORKSTATION

Hitech Electronics Corp.

P-47

PY23=TAIAN N2 PLC PWS-


1.ADP3 PLC

Function

Fnnn

nnn = 0-125

Word(16Bit)

2.:
a.PWS- to N2 (RS232)
FA-RS-232-N2
FA-RS-232-N2
FA-RS-232-N2
b.PWS- to N2 (RS485)
FA-RS-485-KN
FA-RS-485-KN

FA-RS-485-KN

3.: PWS PLC


A. P.L.C.
B. PWS-
a./

RS232C
RS485
b.(STATION No). RS232C=1
RS485=1
c.
RS232C=9600 bps
d.
RS232C =7 bit,odd,1 bit

4.:
1. unsigned binary .
2. F125 , . ( 33333)
3. F0, F21, F42, F63, F84, F105 /.
(BLOCK SIZE 21, 21, 21, 21, 21, 23.)
4. 33333 , Function .
5. Function (), * Function , .
6. double word , Function .(.)
7. PWS : Command Delay (block read 0020 error message).

8. . (unsigned binary )().

P-48

PWS WORKSTATION

PLC PWS

PW03=Telemecanique TSX MICRO PLC


1.ADP3 PLC

Internal Word
Wnnnn
nnnn=0-9999
Word
** 60WordsPLC %MWnnnn.

Block

Bit of Internal Word Wnnnn:bb


nnnn=0-9999; bb=0-15
bb=00 . W0:0
: bit 16bit , PLC
Note : When the Workstation changes a bit, it reads a word from the PLC that contains 16 bits,
changes the desired bit, and writes the word to the PLC. These steps require more than one PLC scan
to complete, so your PLC ladder program must not control other bits within the same word. If it does,
there is a risk that the Workstation will reverse a change that the PLC makes.
For example, if the Workstation changes W1234:7, it reads W1234:0 through W1234:15 as a single
word, changes bit 7 within that word, and writes that entire word back to the PLC. If your PLC ladder
changes some other relay within that word in the meantime, then the Workstation's subsequent write
will cancel that change.

2.:a. COM Port to the RS-232 Port

b. COM Port to TER Port RS485

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.
PWS WORKSTATION

RS232/ RS485
08; MASTER
9600bps/19200bps
8-bit,ODD,1-bit

COM2=RS232/422/485
1. RS485SW10=ON
1. ADP3
PWS18 SLAVE

Hitech Electronics Corp.

P-49

P913=TI435 PLC PWS-


1.ADP3 PLC

Timer Accumulated
Counter Accumulated
V Memory
Link Relays
Input Status
Output Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2

Input Status
Outpuut Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2

Vnnn
Vnnnn
Vnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn

nnn=octal number 0-177


nnnn=octal number 1000-1177
nnnn=octal number 1400-7777
nnnnn=octal number40000-40037
nnnnn=octal number40400-40423
nnnnn=octal number40500-40523
nnnnn=octal number40600-40635
nnnnn=octal number41000-41027
nnnnn=octal number41100-41107
nnnnn=octal number41140-41147
nnnnn=octal number41200-41205
nnnnn=octal number41216-41230

Xnnn
Ynnn
Cnnn
Snnn
Tnnn
CTnnn
SPnnn
SPnnn

nnn=octal number 0-477


nnn=octal number 0-477
nnn=octal number 0-737
nnn=octal number 0-577
nnn=octal number 0-177
nnn=octal number 0-177
nnn=octal number 0-137
nnn=octal number 320-617

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Block
0
0
0
0
0
0
0
0

2.:PWS- to PLC RS232C PORT of TI435

3.: PWS PLC


A. P.L.C.
B. PWS-
COM2=RS232/422/485
RS232C
a./
1. RS422SW10=OFF
2. RS485SW10=ON

b.(STATION No).
c.
d.

9600/19200 bps
1. 8-bit
2.Parity ;ODD
3. 1-bit
e.Comm. Protocol Mode
HEX. (TISOFT AUX26)
## TI435 KOYO SU6 /DL250 P.L.C

P-50

1. ADP3
SW5=OFF
2. PWS-
SW5=ON

PWS WORKSTATION

PLC PWS

PT03=Toshiba M20/M40 PWS-


1.ADP3 PLC

Input Relay Register


Output Relay Register
Internal Relay Register
Link Register
Timer Register
Counter Register
Data Register

XWnn
YWnn
RWnn
ZWnn
Tnnn
Cnn
Dnnnn

nn=0-63
nn=0-63
nn=0-63
nn=0-31
nnn=0-127
nn=0-95
nnnn=0-1535

Word
Word
Word
Word
Word
Word
Word

** 32Words

Input Relay
Output Relay
Internal Relay
Link Relay

Xnnb
Ynnb
Rnnb
Znnb

nn=0-31b=0-f
nn=0-31b=0-f
nn=0-63b=0-f
nn=0-31b=0-f

Block
b=0 . X10
b=0 . Y00
b=0 . R100
b=0 . Z310

2.:PWS- to PLC RS422 Computer Link PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
Programmer/computer link

RS422
Computer link can be used

b.(STATION No).
c.
d.

0
9600bps
(8,E,1);(8,O,1); (8,N,1)

PWS WORKSTATION

COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON

Hitech Electronics Corp.

P-51

PT13=Toshiba T1/T2 PLC PWS-


1.ADP3 PLC

External input register


Output Relay Register
Auxiliary relay register
Special register
Timer register
Counter register
Data register
Link register
Link relay register
File register

XWnn
YWnn
RWnnn
SWnnn
Tnnn
Cnnn
Dnnnn
Wnnnn
LWnnn
Fnnnn

nn=0-63
nn=0-63
nnn=0-127
nnn=0-255
nnn=0-255
nnn=0-255
nnnn=0-4095
nnnn=0-1023
nnn=0-255
nnnn=0-1023

Word
Word
Word
Word
Word
Word
Word
Word
Word
Word

** 32Words

External input device
External output device
Auxiliary relay device
Special device
Link device
Link relay

Xnnb
Ynnb
Rnnnb
Snnnb
Znnnb
Lnnnb

nn=0-63; b= hex number 0-f


nn=0-63; b= 0-f
nnn=0-127; b= 0-f
nnn=0-255; b= 0-f
nnn=0-511; b= 0-f
nnn=0-255; b= 0-f

Block
b=0 . X10
b=0 . Y00
b=0 . R100
b=0 . S230
b=0 . Z30
b=0 . L2550

2.:PWS COM Port to T1 CPU Serial Port

3.: PWS PLC


A. P.L.C.
B. PWS-
COM1/COM2=RS232
RS232
a./
1. ADP3
0 ==T1
b.(STATION No).

P-52

c.

9600bps

d.

8-bit,ODD,1-bit

PLC00(PLC)
1. ADP3
SW5=OFF
2. PWS-
SW5=ON

PWS WORKSTATION

PLC PWS

P013=Unidriver UD70 PLC PWS-


1.ADP3 PLC

Data Register

#70.00~#70.99
#71.00~#71.99
#72.00~#72.99
#73.00~#73.99
#18.01~#18.30
#19.01~#19.30
#20.01~#20.50
#91.01~#91.10

W
0 ~ W 198
W 200 ~ W 398
W 400 ~ W 598
W 600 ~ W 798
W 800 ~ W 858
W 860 ~ W 918
W 920 ~ W1018
W1020 ~ W1029


Bit Relay

#18.31~#18.50
#19.31~#19.50

B0 ~ B19
B20 ~ B39

Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(16Bit)

Block

2.:
a.PWS- to PLC RS232 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.
e.Mode

PWS WORKSTATION

RS485
RS485
Set the parameter of
1. ADP3
UD70 address#14.01 to 11
PLC=11
9600 bps
7-bit, Even , 1-bit
Set the parameter of
UD70 address#14.02 to 06

Hitech Electronics Corp.

P-53

PN23=VIGOR M PLC PWS-


1.ADP3 PLC

Data
Special Data
Timer Register
Counter Register
Counter Register

Dnnnn
Dnnnn
Tnnn
Cnnn
Cnnn

nnn= 0-8191
nnnn=9000-92555
nnn= 0-255
nnn= 0-199
nnn= 200-255


Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Timer Relay
Counter Relay
Timer Coil
Counter Coil

Xnnn
Ynnn
Mnnnn
Snnn
Tnnn
Cnnn
Tnnn
Cnnn

nnn= 0-777
nnn= 0-777
nnnn=0-5119
nnn= 0-999
nnn= 0-255
nnnn=0-255
nnn= 0-255
nnn= 0-255

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(32Bit)
Block

2.:
a.PWS- to PLC RS232 PORT
VIGOR 4-pin male

b.PWS- to PLC RS422 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.

P-54

RS232C,RS422
RS232C=0
RS422=1
19200 bps
7-bit, EVEN , 1-bit

RS232C=0
RS422=1

PWS WORKSTATION

PLC PWS

PY63=YOKOGAWA FA-M3 PLC PWS-


1.ADP3 PLC

Input Relay
Output Relay
Intern Relay
Common Relay
Link Relay
Special Relay
Preset Timer
Set Timer
Preset Counter
Set Counter
Data Register
File Register
Link Register
Special Register
Index Register
Common Register

Xnnnnn
Ynnnnn
Innnnn
Ennnn
Lnnnnn
Mnnnn
TPnnnn
TSnnnn
CPnnnn
CSnnnn
Dnnnn
Bnnnnn
Wnnnn
Znnn
Vnn
Rnnnn

nnnnn= 201-65499(not continue)


nnnnn= 201-65499(not continue)
nnnnn= 1-16384
nnnn= 1-4096
nnnnn= 1-65499(not continue)
nnnn= 1-9984
nnnn= 1-3072
nnnn= 1-3072
nnnn= 1-3072
nnnn= 1-3072
nnnn= 1-8192
nnnnn= 1-32768
nnnnn= 1-65499(not continue)
nnn= 1-512
nn= 1-64
nnnn= 1-4096

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)

X00201
Y00201
I00001
E0001
L00001
M0001
TP0001
TS0001
CP0001
CS0001
D0001
B00001
W00001
Z001
V01
R0001

[ 1] X,Y,L,W, 1 16
[ 2] READ/WRITE 60 words
[ 3] File Register PLC cpu sp25

Iuput Relay
Output Relay
Intern RELAY
Common RELAY
Link RELAY
Special RELAY
Timer
Counter

Xnnnnn
Ynnnnn
Innnnn
Ennnn
Lnnnnn
Mnnnn
TUnnnn
CUnnnn

nnnnn= 201-65499(not continue)


nnnnn= 201-65499(not continue)
nnnn= 1-16384
nnnn= 1-4096
nnnn= 1-65499
nnnn= 1-9984
nnnn= 1-3072
nnnn= 1-3072

Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit

2.:
a.PWS- to PLC RS232 PORT YOKOGAWA CABLE

b.PWS- to PLC RS485

PWS WORKSTATION

Hitech Electronics Corp.

P-55

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
RS232C/ RS485
b.(STATION No). RS232C=1
RS485=1
c.
RS232C=9600 bps
d.
8 bit,even,1 bit

RS232C=1(cpu1-4)
RS485 =1

[ 1] pws YOKOGAWA PLC CPU


CPU pws 1

P-56

PWS WORKSTATION

PLC PWS

PL33=NHP Microlink ML-14 PLC


1.ADP3 PLC

Input/Output
Auxiliary Relay
Keep Relay
Link Relay
Special Relay
Timer
Counter
Step
Data Register

Pnnn
Mnnn
Knnn
Lnnn
Fnnn
Tnnn
Cnnn
Snnn
Dnnn


Input/Output
Auxiliary Relay
Keep Relay
Link Relay
Special Relay

Pnnnb
Mnnnb
Knnn
Lnnn
Fnnn

nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=

0-005
0-031
0-015
0-015
0-015
0-127
0-127
0-031
0-255

Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)

nnn=
nnn=
nnn=
nnn=
nnn=

0-005 ; b=0-f
0-031 ; b=0-f
0-015 ; b=0-f
0-015 ; b=0-f
0-015 ; b=0-f

Block
b=0 . P10

2.:
a.PWS- to PLC RS232 PORT

b.PWS- to PLC RS485 PORT

3.: PWS PLC


A. P.L.C.
B. PWS-
a./
b.(STATION No).

RS232C , RS485

0()
PLC(0-1F)
c.
9600 bps
PLC(300~19200)
d.
8-bit, None , 1-bit
Or 8-bit, None , 2-bit
: RS485 9600, 8-bit, None , 1-bit

PWS WORKSTATION

COM1 or COM2=RS232
COM1 =RS485
1. ADP3
PLC=0

Hitech Electronics Corp.

P-57

P-58

PWS WORKSTATION