PLC PWS
P.L.C. P.L.C.-CPU
PWS- P.L.C.
P513.TSK
P553.TSK
P503.TSK
P523.TSK
P383.TSK
P003.TSK
P013.TSK
P023.TSK
PD13.TSK
PD23.TSK
PZ03.TSK
PH03.TSK
PH23.TSK
P303.TSK
PF03.TSK
PA13.TSK
PA03.TSK
P413.TSK
P403.TSK
PB13.TSK
PWS WORKSTATION
Page
p-4
p-6
p-9
p-10
p-10
p-10
p-11
p-12
p-13
p-13
p-14
p-15
p-16
p-18
P-1
P
The Driver File
P-2
Page
PB03.TSK
PH13.TSK
PE63.TSK
PE53.TSK
PK53.TSK
PK63.TSK
PK33.TSK
PK13.TSK
PK03.TSK
PC03.TSK
P913.TSK
P943.TSK
P803.TSK
PL03.TSK
PL73.TSK
PL53.TSK
PL23.TSK
PL63.TSK
PL43.TSK
P603.TSK
P123.TSK
P703.TSK
P713.TSK
P723.TSK
P853.TSK
P833.TSK
P813.TSK
P823.TSK
P843.TSK
P863.TSK
P803.TSK
P333.TSK
P323.TSK
P343.TSK
P303.TSK
P313.TSK
PL33.TSK
Hitachi H Series
HUST-CNC Controller
IDEC FA-2J
IDEC Micro-3
Jetter NANO-B
Jetter DELTA
Keyence KV Series
Klockner Moeller PS316
Klockner Moeller PS4-201
KOYO SA21
TI 435 / Koyo SU Series / Koyo Direct DL Series
KOYO K-sequence
LG GLOFA GM6 Series
LG K10/60H/200H
LG K200S
LG K300S
LG K500H/1000H
LG Master-K10S/30S/60S/100S
LIYAN PLC-CX
Matsushita FP Series
MIRLE DX Controller
Mitsubishi FX Series
Mitsubishi FX-10GM/20GM Series
Mitsubishi FX2N Series
Mitsubishi A0J2 CPU Series
Mitsubishi A1N CPU Series
Mitsubishi A1S/A2S CPU Port
Mitsubishi A2A/A2AS CPU Port
Mitsubishi A3N/A1SH CPU Series
Mitsubishi AnA/U LINK Series
Mitsubishi AnN/S LINK Series
Modbus master
Modbus slave
Modicon PC984 (RTU mode; master)
Modicon PC984 (RTU mode; slave)
Modicon TSX QUANTUM Series
NHP Microlink ML-14
P000.TSK
p-19
p-20
p-21
p-22
p-22
p-23
p-24
p-25
p-26
p-27
p-28
p-29
p-31
p-32
p-32
p-34
p-34
p-34
p-34
p-34
p-34
p-34
p-36
p-36
p-57
PWS WORKSTATION
The Driver File
P103.TSK
P133.TSK
P113.TSK
PLC PWS
For P.L.C. Brand Name
Omron C Series
Omron CS1 Series
Omron CV Series
p-38
PP13.TSK
PS03.TSK
PY53.TSK
PS13.TSK
PN13.TSK
P203.TSK
SAIA PCD1
Sharp JW10/20 Series
SHINKO CnT Series Temperature Controller
SIDE MIDA 20/20D
Simatic S5 Series (90U, 95U, 115U, 135U) via PG port
P213.TSK
P253.TSK
P263.TSK
P277.TSK
P273.TSK
P273.TSK
PD03.TSK
PY23.TSK
PY03.TSK
PY13.TSK
PW03.TSK
P923.TSK
P913.TSK
P903.TSK
PT03.TSK
PT13.TSK
P013.TSK
P323.TSK
PN23.TSK
PY63.TSK
Vigor M Series
Yokogawa FA-M3 Series
PWS WORKSTATION
Page
p-37
p-39
p-40
p-41
p-42
p-45
p-43
p-48
p-47
p-49
p-23
p-50
p-51
p-52
p-53
p-54
p-55
P-3
p513.tsk= AB Micrologic1000/1500
1.ADP3 PLC
Device Type /
Aux. Address
Output file
O:0.n
n=0-3
0
Input file
I:1.n
n=0-3
1
Status file
S2:nn
nn=0-65
2
Bit file
B3:nnn
nnn=0-255
3
Timer flag
T4:nnn
nnn=0-255
4
Timer Preset Value
T4:nnn.pre
nnn=0-255
5
Timer Accumulator
T4:nnn.acc
nnn=0-255
6
Value
Counter flag
C5:nnn
nnn=0-255
7
Counter Preset Value C5:nnn.pre
nnn=0-255
8
Counter Accumulator C5:nnn.acc
nnn=0-255
9
Value
Control file
R6:nnn
nnn=0-255
10
Control Size of Bit
R6:nnn.len
nnn=0-255
11
Array
Control Reserved file
R6:nnn.pos
nnn=0-255
12
Integer file
N7:nnn
nnn=0-255
13
**T he W ork station doesnot support block read for registers in
Control files.
**You should open those files in the PLC that the W ork station
0
0
2
3
4
4
4
Word
Word
Word
Word
Word
Word
Word
R/W
9
9
9
9
9
9
9
5
5
5
Word
Word
Word
9
9
9
6
6
Word
Word
9
9
9
Word
6
9
Word
7
Tim er, Counter, and
will access.
2.ADP3 PLC
Output
O:0.n/bb
n=0-3; bb=0-15
Input
I:1.n/bb
n=0-3; bb=0-15
Status
S2:nn/bb
nn=0-65; bb=0-15
Bit
B3:nnn/bb
nnn=0-255; bb=0-15
Timer
T4:nnn/bb
nnn=0-255; bb=0-15
Timer Preset Value T4:nnn.pre/bb
nnn=0-255; bb=0-15
Timer Accumulator T4:nnn.acc/bb nnn=0-255; bb=0-15
Value
Counter flag
C5:nnn/bb
nnn=0-255; bb=0-15
Counter Preset
C5:nnn.pre/bb nnn=0-255; bb=0-15
Value
Counter
C5:nnn.acc/bb nnn=0-255; bb=0-15
Accumulator Value
Control
R6:nnn/bb
nnn=0-255; bb=0-15
Control Size of Bit
R6:nnn.len/bb
nnn=0-255; bb=0-15
Array
Control Reserved
R6:nnn.pos/bb nnn=0-255; bb=0-15
Integer
N7:nnn/bb
nnn=0-255; bb=0-15
**T he W ork station doesnot support block read for bits
files.
P-4
Device Type /
Aux. Address
0xC0
0xC1
0xC2
0xC3
0xC4
0xC5
0xC6
0-15
0-15
0-15
0-15
0-15
0-15
0-15
Word
Word
Word
Word
Word
Word
Word
R/W
9
9
9
9
9
9
9
0xC7
0xC8
0-15
0-15
Word
Word
9
9
0xC9
0-15
Word
0xCA
0xCB
0-15
0-15
Word
Word
9
9
9
Word
0xCC
0-15
9
Word
0xCD
0-15
in T im er, Counter, and Control
PWS WORKSTATION
PLC PWS
RS232C
b. NODE ADDRESS.
c.
19200 bps
d.
e. Com Port
1. 8-bit
2.Parity
NONE
1-bit
3.
FULL DUPLEX
YES
PWS WORKSTATION
COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLCN(PLC)
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
P-5
Register Type
Format
Range
Output file
Input file
Status file
Bit file
Timer file
Counter file
Control file
Integer file
O:nn
I:nn
S:nn
Bfff:nnn
B:nnn
Tfff:nnn
T:nnn
Tfff:nnn.PRE
T:nnn.PRE
Tfff:nnn.ACC
T:nnn.ACC
Cfff:nnn
C:nnn
Cfff:nnn.PRE
C:nnn.PRE
Cfff:nnn.ACC
C:nnn.ACC
Rfff:nnn
R:nnn
Rfff:nnn.LEN
R:nnn.LEN
Rfff:nnn.POS
R:nnn.POS
Nfff:nnn
N:nnn
Data Size
nn= 0-30
nn= 0-30
nn=0-31
fff= 3 or 10-255;
default file is 3 if fff omitted; nnn=0-255
fff= 4 or 10-255;
default file is 4 if fff omitted; nnn=0-255
Word
Word
Word
Word
fff=5 or 10-255;
default file is 5 if fff omitted; nnn=0-255
Word
fff=6 or 10-255;
default file is 6 if fff omitted; nnn=0-255
Word
fff=7 or 10-255;
default file is 7 if fff omitted; nnn=0-255
Word
Word
** 30 Words
**T he W ork station doesnot support block read for registers in Tim er, Counter, and
Control files.
**You should open those files in the PLC that the W ork station will access.
P-6
PWS WORKSTATION
PLC PWS
2 .ADP3 PLC
Relay Type
Format
Output file
Input file
Status file
Bit file
O:nn/bb
I:nn/bb
S:nn/bb
Bfff:nnn/bb
Timer file
Tfff:nnn/bb
Tfff:nnn.PRE/bb
Tfff:nnn.ACC/bb
Tfff:nnn.EN
Tfff:nnn.TT
Tfff:nnn.DN
Cfff:nnn/bb
Cfff:nnn.PRE/bb
Cfff:nnn.ACC/bb
Cfff:nnn.CU
Cfff:nnn.CD
Cfff:nnn.DN
Cfff:nnn.OV
Cfff:nnn.UN
Rfff:nnn/bb
Rfff:nnn.LEN/bb
Rfff:nnn.POS/bb
Rfff:nnn.EN
Rfff:nnn.EU
Rfff:nnn.DN
Rfff:nnn.EM
Rfff:nnn.ER
Rfff:nnn.UL
Rfff:nnn.IN
Rfff:nnn.FD
Nfff:nnn/bb
Counter file
Control file
Integer file
Range
nn= 0-30; bb= 0-15
nn= 0-30; bb= 0-15
nn= 0-31; bb= 0-15
fff= 3 or 10-255;
default file is 3 if fff omitted;
nnn=0-255; bb=0-15
fff= 4 or 10-255;
default file is 4 if fff omitted;
nnn=0-255; bb=0-15
fff=5 or 10-255;
default file is 5 if fff omitted;
nnn=0-255; bb=0-15
fff=6 or 10-255;
default file is 6 if fff omitted;
nnn=0-255; bb=0-15
fff=7 or 10-255;
default file is 7 if fff omitted;
nnn=0-255; bb=0-15
** 480 Bits
**T he W ork station doesnot support block read for bits in T im er, Counter, and Control
files.
PWS WORKSTATION
P-7
RS232C SLC-503/504
b. NODE ADDRESS.
c.
d.
9600/19200 bps
1. 8-bit
2.Parity NONE
3. 1-bit
FULL DUPLEX
YES
e. SLC-503/504
f. BCC ERROR Check
P-8
COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLCN(PLC)
PWS WORKSTATION
PLC PWS
Word IO
MWnnnnn
Word Register
RWnnnn
** Word Register (OCT)
Bit IO
Mnnnnn
nnnnn=0 37760(16 )
nnnn=0 - 3071
Word(16Bit)
Word(16Bit)
nnnnn=0-37777
2.:
a.PWS- to PLC RS232 PORT
PWS WORKSTATION
RS232
01(PLC1-247)
9600 bps
8-bit, ODD , 1-bit
RS232
P-9
Data Register
Wnnnn
nnnn=0~4095
Bit Relay
Bnnnn
nnnn=0~1023
Word(16Bit)
Block
2.:
a.PWS- to PLC RS232 PORT
[] PC
3.: PWS PLC
A. P.L.C.
B. PWS-
a./
b.(STATION No).
c.
d.
P-10
RS232C
9600 bps
8-bit, NONE , 1-bit
RS232C
PWS WORKSTATION
PLC PWS
S_Data
X_Data
Y_Data
M_Data
T_Register
C_Register
D_Register
Snnnn
Xnnn
Ynnn
Mnnnn
Tnnn
Cnnn
Dnnnn
nnnn=0-1008 ( 16 )
nnn= 0-360 ( 20 ) []
nnn= 0-360 ( 20 ) []
nnnn=0-1264 ( 16 )
nnn= 0-255
nnnn=0-255
nnnn=0-1279
S_Data
X_Data
Y_Data
M_Data
T_Coil
C_Coil
Snnnn
Xnnn
Ynnn
Mnnnn
Tnnn
Cnnn
nnn=0-1023
nnn=0-377 (8 )
nnn=0-377 (8 )
nnnn=0-1279
nnn=0-255
nnn=0-255
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
PWS WORKSTATION
RS232C
01
9600 bps
7-bit, EVEN , 2-bit
B. PWS-
COM1 or COM2=RS232
1. ADP3
PLC=01
P-11
Word Register
Bit Relay
mmm:Wnnn
mmm=0-255 ; nnn=0-529
Word(16Bit)
mmm:Bnnn
mmm=0-255 ; nnn=0-342
2.:
a.PWS- to PLC RS485 PORT
P-12
RS485
9600 bps
8-bit, EVEN , 1-bit
RS485
PWS WORKSTATION
PLC PWS
Input Relay
WXnnn
nnn=0-9984; ( 0 8 )
Output Relay
WYnnn
nnn=0-9984; ( 0 8 )
Internal Relay
WMnnnn
nnnn=0-9984; ( 0 8 )
Special Relay
WMnnnn
nnnn=0-9984; ( 8 )
Step Relay
WSnnn
nnn=0-9984; ( 0 8 )
Timer Present Value
RTnnnn
nnnn=0-9999
Counter Present Value
RCnnnn
nnnn=0-9999
Data Register
Rnnnnn
nnnn=0-65534
Data Register
Dnnnnn
nnnn=0-65534
** 64Words
Input Relay
Output Relay
Internal Relay
Step Relay
Timer Flag
Counter Flag
Xnnnn
Ynnnn
Mnnnn
Snnnn
Tnnnn
Cnnnn
nnn=0-9999
nnn=0-9999
nnnn=0-9999
nnn=0-9999
nnn=0-9999
nnn=0-9999
Word
Word
Word
Word
Word
Word
Word
Double Word
Word
Block
. X32( 0 8 )
. Y8 ( 0 8 )
. M0 ( 0 8 )
. S16 ( 0 8 )
RS232C
1
c.
9600/19200 bps
d.
7-bit, even,1-bit
2. PWS-
SW5=OFF
SW5=ON
PWS WORKSTATION
P-13
Input
Output
Flag
Timer
Counter
Register
Timer_Preset
Counter_Preset
Input
Output
Flag
Timer
Counter
Timer_on
Timer_off
IWnnn
QWnnn
FWnnnn
TWnnn
CWnnn
Rnnn
TPnnn
CPnnn
nnn=0-255
nnn=0-255
nnnn=0-9999
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Innn.bb
Qnnn.bb
Fnnnn.bb
Tnnn
Cnnn
TONnnn
TOFFnnn
nnn=0-255; bb=0-15
nnn=0-255; bb=0-15
nnnn=0-9999; bb=0-15
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
Block
b=0 . I20.0
b=0 . Q20.0
b=0 . F20.0
2.:
a.PWS- to (TTL RS232C cable)
Festo TTL RS232C
6-pin PLC-port
PLC-port9-pin
9-pin male 9-pin female
P-14
RS232
9600 bps
8-bit, NONE, 1-bit
COM1 or COM2=RS232
PWS WORKSTATION
PLC PWS
Data Register
Special Register
Timer Current Value
Counter Current Value
Input Relay
Output Relay
Internal Relay
Latch Relay
Special Relay
Step Relay
Dnnn
Dnnnn
TNnnn
CNnn
WXnn
WYnn
WMnn
WLnn
WMnnn
WSnnn
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Timer output
Counter output
Input Relay
Output Relay
Internal Relay
Latch Relay
Special Relay
Step Relay
Tnnn
Cnn
Xnnn
Ynnn
Mnnn
Lnnn
Mnnnn
Snnn
Block
0
0
0
0
0
0
0
0
c.
19200 bps
d.
8-bit,ODD,1-bit
e. P.L.C. password
none or 0000-9999
PWS WORKSTATION
B. PWS-
COM= RS422
P-15
Discrete Inputs
%Innnnn
nnnnn=1-12288; 1 16+1
Word
Discrete Outputs
%Qnnnnn
nnnnn=1-12288; 1 16+1
Word
Discrete Temporaries
%Tnnn
nnn=1-256; 1 16 +1
Word
Discrete Internals
%Mnnnnn
nnnnn=1-12288; 1 16+1
Word
%SA Discretes
%SAnnn
nnn=1-128; 1 16 +1
Word
%SB Discretes
%SBnnn
nnn=1-128; 1 16 +1
Word
%SC Discretes
%SCnnn
nnn=1-128; 1 16 +1
Word
%S Discretes
%Snnn
nnn=1-128; 1 16 +1
Word
%Gnnnn
nnnn=1-7680; 1 16 +1
Word
Registers
%Rnnnnn
nnnnn=1-16384
Word
Analog Inputs
%AInnnn
nnnn=1-8192
Word
Analog Outputs
%AQnnnn
nnnn=1-8192
Word
** 50 Words
Block
Discrete Inputs
%Innnnn
nnnnn=1-12288
1 16 +1
Discrete Outputs
%Qnnnnn
nnnnn=1-12288
1 16 +1
Discrete Temporaries
%Tnnn
nnn=1-256
1 16 +1
Discrete Internals
%Mnnnnn
nnnnn=1-12288
1 16 +1
%SA Discretes
%SAnnn
nnn=1-128
1 16 +1
%SB Discretes
%SBnnn
nnn=1-128
1 16 +1
%SC Discretes
%SCnnn
nnn=1-128
1 16 +1
%S Discretes
%Snnn
nnn=1-128
1 16 +1
%Gnnnn
nnnn=1-7680
1 16 +1
** 800 Bits
P-16
PWS WORKSTATION
PLC PWS
2.:
a.PWS RS232 of PLC miniconverter kit
b. PWS RS422 of
19200/9600 bps
8-bit;none,1-bit
e.P.L.C. ID
f. P.L.C. password
blanks
none or ********
PWS WORKSTATION
COM2=RS232/422/485
1. RS422SW10=OFF
00000000 or ********
P-17
Internal Register
Internal Register
Internal Register
Timer/Counter Register
Timer/Counter Register
WMnnn
WMnnn
WMnnn
TCnnn
TCnnn
Word
Word
Word
Word
Word
** 60Words
Input Relay
Xnnn
Output Relay
Ynnn
Auxiliary Relay
Timer/Counter Relay
Mnnn
TCnn
Block
X0,X20,X40
Y200,Y220
M400,M420
TC0,TC1TC80
RS232C
9600 bps
1. ADP3
SW5=OFF
d.
2. PWS-
7-bit ,EVEN, 1- bit
e. CTS Handshanking
Enabled
SW5=ON
Set the PLC's peripheral mode selector switch at the position of COM2 to select the exclusive
protocol.
P-18
PWS WORKSTATION
PLC PWS
Input Relay
Output Relay
Internal Relay
Shift Register
Timer Preset
Timer Current
Counter Preset
Counter Current
Data Register
Calender/Clock
Xn
Yn
Mnn
Rnn
TPnn
Tnn
CPnn
Cnn
Dnn
Wn
n=0-3
n=0-3
nn=0-31
nn=0-48; 0 8
nn=0-31(read only)
nn=0-31
nn=0-31(read only)
nn=0-31
nn=0-99
n=0-6
Byte
Byte
Byte
Bit
Word
Word
Word
Word
Word
Word
** 50 Words
**Timer Preset and Counter Preset are read only. If the value of a TP or CP is in a data
register, then the value read is the address of that data register.
Input Relay
Output Relay
Internal Relay
Shift Register
Timer Status
Counter Status
Xnb
Ynb
Mnnb
Rnn
Tnn
Cnn
n=0-3; b=0-7
n=0-3; b=0-7
nn=0-31; b=0-7
nn=0-63
nn=0-31 read only
nn=0-31 read only
Block
b=0 . X10
b=0 . Y00
b=0 . M10
0 8
0 8
0 8
** 800 bits
2.:PWS-to PLC PROGRAM Loader RS485 PORT(MICRO3-CPU PORT)
0-31255
c.
d.
e.CTS Handshaking
9600bps
7-bit;EVEN; 1-bit
Disabled
1. RS485SW10=ON
1. ADP3
PLC255(PLC)
If your application has only one PLC, then set the parameter to 255; otherwise, set it to the PLC's
"PLC Address for Network Communication" that you set with the program loader
PWS WORKSTATION
P-19
User Register
User Register
Input Relay
Out[ut Relay
Flag Relay
Rnnnn
WRnnnn
nnnn=0-32767
nnnn=0-32767
Inn
Onn
Fnnn
nn=11-58
nn=11-58
nnn=0-255
DWord(32Bit)
Word(16Bit)
2.:
a.PWS- to PLC RS232 PORT (15-pin male)
P-20
RS232C
9600 bps
8-bit, EVEN , 1-bit
COM1 or COM2=RS232
PWS WORKSTATION
PLC PWS
User Register
User Register
Input Relay
Out[ut Relay
Flag Relay
Rnnnn
WRnnnn
Inn
Onn
Fnnn
nnnn=0-64999
nnnn=0-64999
DWord(32Bit)
Word(16Bit)
nnn=101-864
nnn=101-864
nnn=0-2047
2.:
a.PWS- to PLC RS232 PORT (15-pin male)
PWS WORKSTATION
RS232C
9600 bps
8-bit, EVEN , 1-bit
COM1 or COM2=RS232
P-21
PK03=Klockner Moeller PS
1.ADP3 PLC
Word Marker
MWnnnnn
nnnnn=0-32766
Word
** 32Words
Bit Marker0
Block
Mnnnnn.b
nnnnn=0-32766b=0-7
b=0 . M10.0
** 512 bits
P-22
PWS WORKSTATION
PLC PWS
TMR/CTR Accumulater
Register Values
nnn
mmm
Word
Bytes
Block
0
Input/Output Bits
Bnnn
nnn=octal number 0-157
0
Input/Output Bits
Bnnn
nnn=octal number 700-767
0
Internal Relay Bits
Bnnn
nnn=octal number 160-377
0
Shift Register Bits
Bnnn
nnn=octal number 400-577
0
TMR/CTR Bits
Bnnn
nnn=octal number 600-677
When the Workstation changes a relay, it reads a byte from the PLC that contains 8 relays,
changes the desired bit, and writes the byte to the PLC. These steps require more than one PLC
scan to complete, so your PLC ladder program must not control other bits within the same byte. If it
does, there is a risk that the Workstation will reverse a change that the PLC makes.
For example, if the Workstation changes B3, it reads B0 through B7 as a single byte, changes B3
within that byte, and writes that entire byte back to the PLC. If your PLC ladder changes some other
relay within that byte in the meantime, then the Workstation's subsequent write will cancel that
change.
c.
9600/19200 bps
d.
8-bit, odd, 1-bit
e.Operation Mode
RUN Mode
e.Comm. Mode
ASCII mode.sw2-8=ON
PWS WORKSTATION
P-23
Timer Accumulated
Counter Accumulated
V Memory
Link Relays
Input Status
Output Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2
Input Status
Outpuut Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2
Vnnn
Vnnnn
Vnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Xnnn
Ynnn
Cnnn
Snnn
Tnnn
CTnnn
SPnnn
SPnnn
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Block
0
0
0
0
0
0
0
0
P-24
PWS WORKSTATION
PLC PWS
Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Current Value
Counter Current Value
Timer Set Value
Counter Set Value
Data Register
Mnn
Pnn
Knn
Lnn
Fnn
Tnnn
Cnnn
TSnnn
CSnnn
Dnnnn
nn=0-63
nn=0-15
nn=0-31
nn=0-31
nn=0-15
nnn=0-255
nnn=0-255
nnn=0-255
nnn=0-255
nnnn=0-1023
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
** 32 Words
Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Relay
Counter Relay
Mnnb
Pnnb
Knnb
Lnnb
Fnnb
Tnnn
Cnnn
Block
b=0
b=0
b=0
b=0
b=0
0 16
0 16
RS232C
00
9600 bps
d.
8-bit,NONE,1-bit
PWS WORKSTATION
COM1/COM2=RS232
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
P-25
I/O Relay
AUX Relay
Keep Relay
Link Relay
Special Relay
Timer
Counter
Step controller
Data Register
PWnn
MWnnn
KWnn
LWnn
FWnn
TWnnn
CWnnn
SWnnnn
DWnnnn
nn= 0-31
nnn = 0-191
nn = 0-31
nn = 0-63
nn = 0-63
nnn = 0-255
nnn = 0-255
nnnn = 0-9999
nnnn = 0-9999
I/O Relay
AUX Relay
Keep Relay
Link Relay
Special Relay
PWnnb
MWnnnb
KWnnb
LWnnb
FWnnb
nn= 0-31
b=0-f
nnn = 0-191 b=0-f
nn = 0-31
b=0-f
nn = 0-63
b=0-f
nn = 0-63
b=0-f
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Block
2.:
PWS- to PLC RS232 PORT
RS232C
P-26
PWS WORKSTATION
PLC PWS
Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Timer Current Value
Counter Current Value
Data Register
Mnnn
Pnn
Knn
Lnn
Fnn
Tnnn
Cnnn
Dnnnn
nnn=0-191
nn=0-63
nn=0-31
nn=0-63
nn=0-31
nnn=0-255
nnn=0-255
nnnn=0-9999
Word
Word
Word
Word
Word
Word
Word
Word
** 32 Words
Auxiliary Relay
Input/Output Relay
Keep Relay
Link Relay
Special Relay
Mnnnb
Pnnb
Knnb
Lnnb
Fnnb
Block
b=0
b=0
b=0
b=0
b=0
2.:
a.PW S to RS232 of PLC-K1000H CPU ;
RS422RS232C
RS422
RS232
00(CPU PORT)
00--15(RS422)
9600/19200 bps
8-bit,NONE,1-bit
COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
PLC00(PLC)
P-27
Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Data
Special Data
Timer Preset Register
Counter Preset Register
Timer Current Register
Counter Current Register
Timer Preset Register
Counter Preset Register
Timer Current Register
Counter Current Register
Xnnn
Ynnn
Mnnnn
Snnn
Dnnnn
Dnnnn
PTnnn
PCnnn
CTnnn
CCnnn
PTnnn
PCnnn
CTnnn
CCnnn
nnn= 0-076
nnn= 0-076
nnnn=0-8254
nnn= 0-510
nnn= 0-511
nnnn=8000-8255
nnn= 0-063
nnn= 0-063
nnn= 0-063
nnn= 0-063
nnn= 224-255
nnn= 224-255
nnn= 224-255
nnn= 224-255
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Data
Special Data
Timer Relay Status
Counter Relay Status
Xnnnb
Ynnnb
Mnnnnb
Snnnb
Dnnnb
Dnnnnb
Tnnnb
Cnnnb
Block
b=0 . X200
b=0 . Y200
b=0 . M200
2.:
a.PWS- to PLC RS232 PORT
P-28
a./
RS232C
b.(STATION No).
c.
d.
9600 bps
8-bit, EVEN , 1-bit
COM1 or COM2=RS232
PWS WORKSTATION
PLC PWS
Internal Relay
Special Internal
Relay
Link Relay
External Input
Relay
External Output
Relay
Timer/Counter
P.V.
Timer/Counter
S.V.
Data Register
Special Data
Register
Link
Data
Register
File Register
Block read
WRnn
WRnnn
nn=0-97(875)
nnn=900-910
Device Type /
Aux. Address
0
0
1
0
WLnnn
WXnnn
nnn=0-127(639)
nnn=0-127(255)
2
3
0
0
Word
Word
WYnnn
nnn=0-127(255)
Word
EVnnn
nnn=0-255(2047)
Word
SVnnn
nnn=0-255 (2047)
Word
DTnnnn
DTnnnn
nnnn=0-2047 (10239)
nnnn=9000-9255
7
8
0
0
Word
Word
LDnnn
nnn=0-127(8447)
Word
FLnnnnn
nnnn=0-8191 (32764)**
10
Word
R/W
Word
Word
** 27 Words
**The Register setting range of FP10SH is nnnnn=0- 32764.
Internal Relay
Special Internal Relay
Link Relay
External Input Relay
External Output Relay
Timer Flag Contact
Counter Flag Contact
Rnnnb
Rnnnb
Lnnnb
Xnnnb
Ynnnb
Tnnn
Cnnn
nn=0-97(875);b= 0-f
nnn=900-910;b= 0-f
nnn=0-127(639);b=0-f
nnn=0-127(255);b=0-f
nnn=0-127(255);b=0-f
nnn=0-255(2047)
nnn=0-255(2047)
Block
b=0 . R1230
b=0 . R9100
b=0 . L110
b=0 . X00
b=0 . Y00
0 16
0 16
** 432 Bits
**The Relay setting range of FP10SH is nnnn=0-2047
2.:
a.PWS- to PLC RS232C LINK of
PWS WORKSTATION
P-29
b.PWS- to PLC
RS422
of
c.
d.
P-30
RS422RS232C
01-32
FP CPU PORT =238
FP1computer link
19200/9600 bps
FP10SH -CPU115.2K bps
8-bit,odd, 1-bit
COM2=RS232/422/485
1. ADP3
PLC01(PLC)
CPU PORT238
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS WORKSTATION
PLC PWS
**DM area
DM area
DMnnnn
DMnnnn
nnnn=0-575
nnnn=0-287
Word(32bits)
Word(16bits)
DM=0-47
DM=0-23
IRnnn
IRnnn
IRnnnn
nnn=0-15,100-115
nnn=400-515
nn=800-1315
IR=6-15,100-115
IR=1200-1307
2.:
a.PWS to MIRLE DX RS422 PORT
RS232C/ RS422
0
c.
9600 bps
d.
PWS WORKSTATION
COM2=RS232/422
1. ADP3
PLC00
P-31
Auxiliary Relay
Special Auxiliary Relay
Status Relay
Input Relay
Output Relay
Timer PV
16-bit Counter PV
32-bit Counter PV
Data Register
Special Data Register
Mnnnn
Mnnnn
Snnn
Xnnn
Ynnn
Tnnn
Cnnn
Cnnn
Dnnn
Dnnnn
nnnn=0-3071; 0 8
nnnn=8000-8255; 0 8
nnn=0-999; 0 8
nnn=octal number 0-377; 0
nnn=octal number 0-377; 0
nnn=0-255
nnn=0-199
nnn=200-255
nnn=0-1023(7999) D1000=FILE REGISTER
nnnn=8000-8255
Word
Word
Word
Word
Word
Word
Word
DWord
Word
Word
** 32 Words
Auxiliary Relay
Special Auxiliary Relay
Status Relay
Input Relay
Output Relay
Timer Flag
Counter Flag
Mnnnn
Mnnnn
Snnn
Xnnn
Ynnn
Tnnn
Cnnn
0-3071
8000-8255
0-999
Octal number 0-377
Octal number 0-377
0-255
0-255
Block
0 8
0 8
0 8
0
0
0 8
0 8
** 512 bits
2.:
a. PWS to RS422 of PLC-FX2 CPU
P-32
PWS WORKSTATION
PLC PWS
PWS WORKSTATION
P-33
Input Relay
Output Relay
Link Relay
Internal Relay
Special Relay
Latch Relay
Annunciator
Timer PV
Counter PV
Data Register
Special Register
File Register
Link Register
Xnnn
Ynnn
Bnnn
Mnnnn
Mnnnn
Lnnnn
Fnnnn
TNnnn
CNnnn
Dnnnn
Dnnnn
Rnnnn
Wnnn
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
** 64 Words
Input Relay
Output Relay
Link Relay
Internal Relay
Special Relay
Latch Relay
Annunciator
Timer Contact
Timer Coil
Counter Contact
Counter Coil
Xnnn
Ynnn
Bnnn
Mnnnn
Mnnnn
Lnnnn
Fnnnn
TSnnn
TCnnn
CSnnn
CCnnn
Block
0
0
0
0 16
3 16
0 16
0 16
0 16
0 16
0 16
0 16
** 512 bits
2.: a.PWS PLC
P-34
AJ71UC24-R2/S8
PWS WORKSTATION
PLC PWS
RS422
A. P.L.C.
a./
AJ71UC24 sw1=ON
sw1=Off
b.(STATION No).
c.
d.
e.Comm. Protocol
f.Check Sum
g.Write during Run
B. PWS-
RS422RS232C
RS422
RS232
00(CPU PORT)
00(AISJ71C24-S3)
00-31(AJ71UC24)
9600/19200 bps
CPU PORT=9600bps
8-bit,ODD,1-bit
Format 1;5;A
YES
Allowed
COM2=RS232/422/485
1. RS422SW10=OFF
1. ADP3
PLC00(PLC)
255
PWS
Set the address of the Workstation as 255 and the address of the PLC as 0 when an A1SJ71C24 or
AJ71C24 is used for the communications.
To connect the Workstation to the PLC CPU port, set the Workstation communication parameters
according to the following; set the DIP switch No.10 to off when COM2 is used.
Baud Rate = 9600; Data Format = (8 data bits, odd parity, 1 stop bit)
PWS WORKSTATION
P-35
P303=Modicon PC984
P313=Modicon TSX Quantum
1.ADP3 PLC
Input Registers
nnnnn
nnnnn=30001-39999
Output Registers
nnnnn
nnnnn=40001-49999
Input Registers(TSX Quantum)
nnnnnn
nnnnn=300001-365535
Output Registers(TSX Quantum)
nnnnnn
nnnnn=400001-565535
** 125 Words
Word
Word
Word
Word
Discrete Outputs
nnnnn
nnnnn=1-9999
Discrete Inputs
nnnnn
nnnnn=10001-19999
Discrete Outputs(TSX Quantum) nnnnn
nnnnn=000001-065535
Discrete Inputs (TSX Quantum) nnnnn
nnnnn=100001-165535
** 2000 Bits
2.: PWS to RS232 of PLC CPU port
P-36
PWS WORKSTATION
PLC PWS
IR area
HR area
AR area
LR area
TC area
DM area
IRnnn
HRnn
ARnn
LRnn
TCnnn
DMnnnn
IR area
HR area
AR area
LR area
TC area
IRnnnbb
HRnnbb
ARnnbb
LRnnbb
TCnnn
Block read
nnn=0-255
nn=0-99
nn=0-27
nn=0-63
nnn=0-511
nnnn=0-6655
Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)
Word(16bit)
nnn=0-255; bb=00-15
nn=0-99 ; bb=00-15
nn=0-27 ; bb=00-15
nn=0-63 ; bb=00-15
nnn=0-511
Block
bb=00 . IR12300
bb=00 . HR2300
bb=00 . AR100
bb=00 . LR2300
16 . TC16
Max. 28
Max. 28
Max. 28
Max. 28
Max. 28
Max. 28
2.:
a.PWS- to PLC RS232C HOST LINK of
LK201/ C200HS/C28H/C40H/CQM1
b.PWS- to PLC
C200H-LK202
COM2=RS232/422/485
1. ADP3
PLC00(PLC)
P-37
Timer
Counter
Register
Input
Output
Flag
Tnnnn
Cnnnn
Rnnnn
nnnn=0-1599
nnnn=0-1599
nnnn=0-4095
Innn
Onnn
Fnnnn
nnn=0-255
nnn=0-255
nnn=0-8191
DWord(32Bit)
DWord(32Bit)
DWord(32Bit)
2.:
a. PWS- to PLC RS232 PORT
P-38
RS232C
9600 bps
8-bit, None , 1-bit
COM1 or COM2=RS232
PWS WORKSTATION
PLC PWS
Register
Wnnnn
nnnn= 0-1599
I/O Relay
Bnnn
nnn= 0-999
Word(16Bit)
Block
2.:
a.PWS- to PLC RS232 PORT
RS232C
RS485
b.(STATION No). RS232C=153
RS485=1
c.
RS232C=9600 bps
RS485 =9600 bps
d.
RS232C =7 bit,none,1 bit
RS485 =8 bit,even,1 bit
e.
RS232C=stop mode
RS485 =running mode
PWS WORKSTATION
P-39
Input Image
Output Image
Extended I/O
Flag Bits
Peripheral I/O
System Data Area
System Data Area
System Data Area
System Data Area
Timer Current
Counter Current
Data Block
IBnnn
QBnnn
OBnnn
FBnnn
PBnnn
RSnnn
RInnn
RJnnn
RTnnn
Tnnn
Cnnn
DBmmm/nnn
DBnnn
Data Block
DWmmm/nnn
DWnnn
nnn=0-127
Byte
Max. 30
nnn=0-127
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Byte
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
nnn=0-255
Word
Max. 30
Max. 30
mmm=0-255; mmm is Block number
nnn=0-255; nnn is the numbers which
defines block. If the mmm not set the
numbers, the numbers of mmm is 3= DB3/nnn
Max. 30
mmm=0-127; mmm is Block number
nnn=0-255; nnn is the numbers which
defines block. If the mmm not set the
numbers, the numbers of mmm is 3= DW3/nnn
** 30 Words
Input Image
Output Image
Extended I/O
Flag Bits
Peripheral I/O
IBnnn.b
QBnnn.b
OBnnn.b
FBnnn.b
PBnnn.b
nnn=0-127; b=0-7
nnn=0-127; b=0-7
nnn=0-255; b=0-7
nnn=0-255; b=0-7
nnn=0-255; b=0-7
Block
b=0 . IB30.0
b=0 . QB2.0
b=0 . OB0.0
b=0 . FB23.0
b=0 . PB23.0
P-40
RS-232/Current-loop converter
9600 bps
8-bit, EVEN ,1-bit
PLCData Block
n=3255 OPEN
COM1 or COM2=>RS232
PLC. MODE CODE
0: 90U
1: 95U
2:100U
3:102U 4:103U
5:115U
6:135U/921
7:135U/922 8:135U/928
PWS Command Delay
PWS WORKSTATION
PLC PWS
Input Image
Input Image
Output Image
Output Image
Internal Bits
Internal Bits
Timer
Counter
Special S
Special S
Special Bits
Special Bits
Special Bits
Analog input word
Analogoutputword
Data Area
Data Area
IWn
IDn
QWn
QDn
MWnn
MDnn
Tnnn
Cnnn
SWnn
SDnn
SMWnnn
SMWnnn
SMDnnn
AIWnn
AQWnn
VWnnnn
VDnnnn
n=0-6
n=0-4
n=0-6
n=0-4
nn=0-30
nn=0-28
nnn=0-255
nnn=0-255
nn=0-30
nn=0-28
nnn=0-27
nnn=28-192
nnn=0-190
nn=0-30
nn=0-30
nnnn=0-5118
nnnn=0-5116
Word
Double Word
Word
Double Word
Word
Double Word
Word
Word
Word
Double Word
Word* read only
Word
Double Word
Word* read only
Word* read only
Word
Double Word
n=0-7; b=0-7
n=0-7; b=0-7
nn=0-31;b=0-7
nnn=0-255
nnn=0-255
nnn=0-193 ;b=0-7
nnnn=0-5119 ;b=0-7
nn=0-31; b=0-7
Block
b=0 . I3.0
b=0 . Q2.0
b=0 . M0.0
b=0 .T0 *read only
b=0 .C0 *read only
b=0 . SM23.0
b=0 . V2323.0
b=0 . S25.0
In.b
Qn.b
Mnn.b
Tnnn
Cnnn
SMnnn.b
Vnnnn.b
Snn.b
RS485
02(01-32)
9600 /19200bps
8-bit, EVEN, 1-bit
COM2=RS232/422/485
1. RS485SW10=ON
P-41
DBmmm.DBWnnnn
mmm=1-255
nnnn=0-8190
DBmmm.DBDnnnn
mmm=1-255
nnnn=0-8188
Word
Double
Word
** 32 Words
DBmmm.DBXnnnn.b
mmm=1-255
nnnn=0-8190
b=0-7
Block
P-42
b.(STATION No).
c.
RS232=CP340
RS422=CP340
RS485=CP340
9600 /19200bps
d.
e.FUNCTION BLOCK
FB40,FB2,FB3,DB2,DB3 for CP
COM2=RS232/RS422/RS485
1. RS422SW10=OFF
2. RS485SW10=ON
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS WORKSTATION
PLC PWS
Device Type /
Aux. Address
Input Image
Input Image
Output Image
Output Image
Bits
Bits
Data Area
(DB10)
Data Area
(DB10)
Data Area
(DB10)
IWnnnnn
IDnnnnn
QWnnnnn
QDnnnnn
MWnnn
MDnnn
VWnnnnn
nnnnn=0-65534
nnnnn=0-65532
nnnnn=0-65534
nnnnn=0-65532
nnnnn=0-254
nnnnn=0-252
nnnnn=0-65534
0
1
2
3
4
5
6
0
0
0
0
0
0
0
Word
DWord
Word
DWord
Word
DWord
Word
R/W
9
9
9
9
9
9
9
VDnnnnn
nnnnn=0-65532
DWord
DBWnnnnn
Word
Data Area
(DB10)
DBDnnnnn
DWord
Data Area
DBmmm.DBW
nnnnn
DBmmm.DBD
nnnnn
Word
DWord
Data Area
Input Image
Output Image
Bit
Data Area Bit
(=DB10)
Data Area Bit
(=DB10)
Device Type /
Aux. Address
Innnnn.b
Qnnnnn.b
Mnnn.b
Vnnnnn.b
nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
nnn=0-255; b=0-7
nnnn=0-65535; b=0-7
0xC0
0xC1
0xC2
0xC3
0-7
0-7
0-7
0-7
Block
R/W
9
Bit
9
Bit
9
Bit
9
Bit
DBXnnnn.b
nnnnn=0-65535; b=0-7
0xC4
0-7
Bit
0xC5
0-7
Bit
2.:
a.PWS- to PLC MPI CABLE RS232C PORT MPI 6ES7-972-0CA21-0XA0
PWS WORKSTATION
P-43
c. Exam ple of the connections between PW S & S7-300/400 CPU MPI port:
P-44
a./
b.(STATION No).
c.
19200/38400 bps
d.
e. Command Delay
f. DATA BLOCK
COM1 or COM2=RS232
1. ADP3
PLC=02
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS Command Delay
PWS WORKSTATION
PLC PWS
Input Image
Input Image
Output Image
Output Image
Bits
Bits
Timer Image
Timer Image
Timer Image
Timer Image
Counter Image
DBmmm.DBWnnnnn
IWnnnnn
IDnnnnn
QWnnnnn
QDnnnnn
MWnnn
MDnnn
Tnnnnn.10ms
Tnnnnn.100ms
Tnnnnn.1s
Tnnnnn.10s
Cnnnnn
mmm=1-255
nnnn=0-65534
DBmmm.DBDnnnnn
mmm=1-255
nnnn=0-65532
DBWnnnnn
DBDnnnnn
VWnnnnn
VDnnnnnn
Input Image
Output Image
Bit
Data Area Bit
Innnnn.b
Qnnnnn.b
Mnnnnn.b
DBmm.DBXnnnnn.b
DBXnnnnn.b
PWS WORKSTATION
nnnnn=0-65534 length=1-1023
nnnnn=0-65532 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65532 length=1-1023
nnnnn=0-65534 length=1-128
nnnnn=0-65532 length=1-128
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnnn=0-65534 length=1-1023
nnnn=0-65534; DBWnnnn is a word
address, the Byte nnnn & nnnn+1
make DBWnnnn
nnnnn=0-65532;DBDnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn
nnnnn=0-65534; DBWnnnnn is a
word address, the Byte nnnnn &
nnnnn+1 make DBWnnnnn
nnnnn=0-65532; DBDnnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn
nnnnn=0-65534; VWnnnnn is a word
address, the Byte nnnnn & nnnnn+1
make DBWnnnnn
nnnnn=0-65532; VDnnnnn is a
double word address, the DBWnnnn
& DBWnnnn+1 make DBDnnnn
nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
nnnnn=0-65535; b=0-7
mmm=1-31
nnnnn=0-65535 ;b=0-7
nnnnn=0-65535 ;b=0-7
Vnnnnn.b
nnnnn=0-65535; b=0-7
DB10.DBXnnnnn.b is a bit address, It is in #b bit
of #nnnnn word with DB10
Word
Double Word
Word
Double Word
Word
Double Word
Word
Word
Word
Word
Word
Word
Double Word
Word
Double Word
Word
Double Word
Block
b=0 . I3.0
b=0 . Q2.0
b=0 . M0.0
b=0 . DB22.DBX20.0
b=0 . DBX23.0
DBX23.0=DB10.DBX23.0
b=0 . V23.0
V23.0=DB10.DBX23.0
P-45
P-46
COM2=RS232
PWS Command Delay Setting
PWS WORKSTATION
PLC PWS
Input
Output
Auxiliary Register
Auxiliary Register
System Register
Auxiliary Relay Register
Constant Register
Input
Output
Auxiliary Relay
Special Relay
Xnnn
Ynnn
Vnnnn
Dnnnn
WSnnn
Cnnnn
WCnnn
nnn=1-369( 1 16+1 )
nnn=1-369( 1 16+1 )
nnnn=1-1024
nnnn=1-2048
nnn=1-128
nnnn=1-2033( 1 16+1 )
nnn=1-912
Xnnn
Ynnn
Cnnnn
SCnnn
nnn=1-384
nnn=1-384
nnnn=1-2048
nnn=1-128
Word
Word
Word
Word
Word
Word
Word
2.:
a.PWS- to PLC RS422 PORT of TP02
RS422/485
01
c.
d.
19200 bps
7-bit, EVEN , 2-bit
1. ADP3
PLC=01
PWS WORKSTATION
P-47
Function
Fnnn
nnn = 0-125
Word(16Bit)
2.:
a.PWS- to N2 (RS232)
FA-RS-232-N2
FA-RS-232-N2
FA-RS-232-N2
b.PWS- to N2 (RS485)
FA-RS-485-KN
FA-RS-485-KN
FA-RS-485-KN
RS232C
RS485
b.(STATION No). RS232C=1
RS485=1
c.
RS232C=9600 bps
d.
RS232C =7 bit,odd,1 bit
4.:
1. unsigned binary .
2. F125 , . ( 33333)
3. F0, F21, F42, F63, F84, F105 /.
(BLOCK SIZE 21, 21, 21, 21, 21, 23.)
4. 33333 , Function .
5. Function (), * Function , .
6. double word , Function .(.)
7. PWS : Command Delay (block read 0020 error message).
P-48
PWS WORKSTATION
PLC PWS
Internal Word
Wnnnn
nnnn=0-9999
Word
** 60WordsPLC %MWnnnn.
Block
RS232/ RS485
08; MASTER
9600bps/19200bps
8-bit,ODD,1-bit
COM2=RS232/422/485
1. RS485SW10=ON
1. ADP3
PWS18 SLAVE
P-49
Timer Accumulated
Counter Accumulated
V Memory
Link Relays
Input Status
Output Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2
Input Status
Outpuut Status
Control Relays
Stage
Timer Status
Counter Status
Spec. Relay 1
Spec. Relay 2
Vnnn
Vnnnn
Vnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Vnnnnn
Xnnn
Ynnn
Cnnn
Snnn
Tnnn
CTnnn
SPnnn
SPnnn
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Block
0
0
0
0
0
0
0
0
b.(STATION No).
c.
d.
9600/19200 bps
1. 8-bit
2.Parity ;ODD
3. 1-bit
e.Comm. Protocol Mode
HEX. (TISOFT AUX26)
## TI435 KOYO SU6 /DL250 P.L.C
P-50
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS WORKSTATION
PLC PWS
XWnn
YWnn
RWnn
ZWnn
Tnnn
Cnn
Dnnnn
nn=0-63
nn=0-63
nn=0-63
nn=0-31
nnn=0-127
nn=0-95
nnnn=0-1535
Word
Word
Word
Word
Word
Word
Word
** 32Words
Input Relay
Output Relay
Internal Relay
Link Relay
Xnnb
Ynnb
Rnnb
Znnb
nn=0-31b=0-f
nn=0-31b=0-f
nn=0-63b=0-f
nn=0-31b=0-f
Block
b=0 . X10
b=0 . Y00
b=0 . R100
b=0 . Z310
RS422
Computer link can be used
b.(STATION No).
c.
d.
0
9600bps
(8,E,1);(8,O,1); (8,N,1)
PWS WORKSTATION
COM2=RS232/422/485
1. RS422SW10=OFF
2. RS485SW10=ON
P-51
XWnn
YWnn
RWnnn
SWnnn
Tnnn
Cnnn
Dnnnn
Wnnnn
LWnnn
Fnnnn
nn=0-63
nn=0-63
nnn=0-127
nnn=0-255
nnn=0-255
nnn=0-255
nnnn=0-4095
nnnn=0-1023
nnn=0-255
nnnn=0-1023
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
** 32Words
External input device
External output device
Auxiliary relay device
Special device
Link device
Link relay
Xnnb
Ynnb
Rnnnb
Snnnb
Znnnb
Lnnnb
Block
b=0 . X10
b=0 . Y00
b=0 . R100
b=0 . S230
b=0 . Z30
b=0 . L2550
P-52
c.
9600bps
d.
8-bit,ODD,1-bit
PLC00(PLC)
1. ADP3
SW5=OFF
2. PWS-
SW5=ON
PWS WORKSTATION
PLC PWS
Data Register
#70.00~#70.99
#71.00~#71.99
#72.00~#72.99
#73.00~#73.99
#18.01~#18.30
#19.01~#19.30
#20.01~#20.50
#91.01~#91.10
W
0 ~ W 198
W 200 ~ W 398
W 400 ~ W 598
W 600 ~ W 798
W 800 ~ W 858
W 860 ~ W 918
W 920 ~ W1018
W1020 ~ W1029
Bit Relay
#18.31~#18.50
#19.31~#19.50
B0 ~ B19
B20 ~ B39
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(32Bit)
Word(16Bit)
Block
2.:
a.PWS- to PLC RS232 PORT
PWS WORKSTATION
RS485
RS485
Set the parameter of
1. ADP3
UD70 address#14.01 to 11
PLC=11
9600 bps
7-bit, Even , 1-bit
Set the parameter of
UD70 address#14.02 to 06
P-53
Data
Special Data
Timer Register
Counter Register
Counter Register
Dnnnn
Dnnnn
Tnnn
Cnnn
Cnnn
nnn= 0-8191
nnnn=9000-92555
nnn= 0-255
nnn= 0-199
nnn= 200-255
Input Relay
Output Relay
Auxiliary Relay
ST1 Status
Timer Relay
Counter Relay
Timer Coil
Counter Coil
Xnnn
Ynnn
Mnnnn
Snnn
Tnnn
Cnnn
Tnnn
Cnnn
nnn= 0-777
nnn= 0-777
nnnn=0-5119
nnn= 0-999
nnn= 0-255
nnnn=0-255
nnn= 0-255
nnn= 0-255
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(32Bit)
Block
2.:
a.PWS- to PLC RS232 PORT
VIGOR 4-pin male
P-54
RS232C,RS422
RS232C=0
RS422=1
19200 bps
7-bit, EVEN , 1-bit
RS232C=0
RS422=1
PWS WORKSTATION
PLC PWS
Input Relay
Output Relay
Intern Relay
Common Relay
Link Relay
Special Relay
Preset Timer
Set Timer
Preset Counter
Set Counter
Data Register
File Register
Link Register
Special Register
Index Register
Common Register
Xnnnnn
Ynnnnn
Innnnn
Ennnn
Lnnnnn
Mnnnn
TPnnnn
TSnnnn
CPnnnn
CSnnnn
Dnnnn
Bnnnnn
Wnnnn
Znnn
Vnn
Rnnnn
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
X00201
Y00201
I00001
E0001
L00001
M0001
TP0001
TS0001
CP0001
CS0001
D0001
B00001
W00001
Z001
V01
R0001
[ 1] X,Y,L,W, 1 16
[ 2] READ/WRITE 60 words
[ 3] File Register PLC cpu sp25
Iuput Relay
Output Relay
Intern RELAY
Common RELAY
Link RELAY
Special RELAY
Timer
Counter
Xnnnnn
Ynnnnn
Innnnn
Ennnn
Lnnnnn
Mnnnn
TUnnnn
CUnnnn
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
2.:
a.PWS- to PLC RS232 PORT YOKOGAWA CABLE
PWS WORKSTATION
P-55
RS232C=1(cpu1-4)
RS485 =1
P-56
PWS WORKSTATION
PLC PWS
Input/Output
Auxiliary Relay
Keep Relay
Link Relay
Special Relay
Timer
Counter
Step
Data Register
Pnnn
Mnnn
Knnn
Lnnn
Fnnn
Tnnn
Cnnn
Snnn
Dnnn
Input/Output
Auxiliary Relay
Keep Relay
Link Relay
Special Relay
Pnnnb
Mnnnb
Knnn
Lnnn
Fnnn
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
nnn=
0-005
0-031
0-015
0-015
0-015
0-127
0-127
0-031
0-255
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
Word(16Bit)
nnn=
nnn=
nnn=
nnn=
nnn=
0-005 ; b=0-f
0-031 ; b=0-f
0-015 ; b=0-f
0-015 ; b=0-f
0-015 ; b=0-f
Block
b=0 . P10
2.:
a.PWS- to PLC RS232 PORT
RS232C , RS485
0()
PLC(0-1F)
c.
9600 bps
PLC(300~19200)
d.
8-bit, None , 1-bit
Or 8-bit, None , 2-bit
: RS485 9600, 8-bit, None , 1-bit
PWS WORKSTATION
COM1 or COM2=RS232
COM1 =RS485
1. ADP3
PLC=0
P-57
P-58
PWS WORKSTATION