Вы находитесь на странице: 1из 6

Contract No : RDA/ NRRP/ CGF/C1B Bill Item : 6.2.

22
Road No : Description : Tor Steel Reinforcement
Structure : 265/1 Bridge Reference : 1002(1)
Sheet No : Date : 2011.10.30
M/IS-28/03/1/S1/12
265/1
B/S
1 10 104 450 0.617
2 10 104 755 0.617
3 16 4 10,300 1.579
Dowels
4 20 21 300 2.467
CONSULTANT'S
TECHNICAL OFFICER
CONTRACTOR'S
REPRESENTATIVE
RECOMMENDED BY
RESIDENT ENGINEER
CHECKED BY
SITE ENGINEER
Bar Size
No. of
Bars
Weight per
1m Length
CONSULTANT: CONTRACTOR:
Bridge
No
Length of
Bar
NORTHERN ROADS REHABILITATION PROJECT
EMPLOYER:
Bar Shape
Central Engineering Consultancy Bureau CATIC/MAGA
AGREED SITE MEASUREMENT RECORD
Road Development Authority
(To be Completed Daily )
Bar No.
Reinforcement Capping Beam Jaffna End
Total Quantity
210 mm
80mm
80 mm
1
385 mm
75mm
150mm
2
10300 mm
3
300 mm
4
28.88
48.45
65.05
15.54
157.92
RECOMMENDED BY
RESIDENT ENGINEER
CONTRACTOR:
NORTHERN ROADS REHABILITATION PROJECT
CATIC/MAGA
AGREED SITE MEASUREMENT RECORD
(To be Completed Daily )
Weight
(kg)
Contract No : RDA/ NRRP/ CGF/C1B Bill Item : 03
Road No : Description : Tor Steel Reinforcement
Structure : 265/1 Bridge Reference : 1002(1)
Sheet No : Date : 2011.10.30
M/IS-28/03/1/S1/13
265/1
B/S
1 10 104 510 0.617
2 10 104 755 0.617
3 16 4 10,300 1.579
Dowels
4 20 21 300 2.467
Total Quantity
CONTRACTOR'S
REPRESENTATIVE
CONSULTANT'S
TECHNICAL OFFICER
CHECKED BY
SITE ENGINEER
RECOMMENDED BY
RESIDENT ENGINEER
Reinforcement Capping Beam Paranthan End
AGREED SITE MEASUREMENT RECORD
(To be Completed Daily )
Bridge
No
Bar Shape Bar No. Bar Size
No. of
Bars
Length of
Bar
Weight per
1m Length
NORTHERN ROADS REHABILITATION PROJECT
EMPLOYER: CONSULTANT: CONTRACTOR:
Road Development Authority Central Engineering Consultancy Bureau CATIC/MAGA
210 mm
110 mm
80 mm
1
385 mm
75mm
150mm
2
10300 mm
3
300 mm
4
32.73
48.45
65.05
15.54
161.77
RECOMMENDED BY
RESIDENT ENGINEER
AGREED SITE MEASUREMENT RECORD
(To be Completed Daily )
Weight
(kg)
NORTHERN ROADS REHABILITATION PROJECT
CONTRACTOR:
CATIC/MAGA
Contract No : RDA/ NRRP/ CGF/C1B Bill Item : 03
Road No : Description : Tor Steel Reinforcement
Structure : 265/1 Bridge Reference : 1002(1)
Sheet No : Date : 2013.11.30
M/IS-29/03/1/S1/32
265/1
B/S Deck
2 10 34 15,400 0.617
3 10 104 8,160 0.617
4 10 106 1,290 0.617
5 10 106 2,080 0.617
6 10 106 1,260 0.617
7 10 106 1,670 0.617
8 12 46 15,400 0.888
Tie Beam
9 10 20 1,400 0.617
10 10 20 1,580 0.617
11 6 70 440 0.222
NORTHERN ROADS REHABILITATION PROJECT
EMPLOYER: CONSULTANT: CONTRACTOR:
Road Development Authority Central Engineering Consultancy Bureau CATIC/MAGA
AGREED SITE MEASUREMENT RECORD
(To be Completed Daily )
Bridge
No
Bar Shape Bar No. Bar Size
No. of
Bars
Length of
Bar
Weight per
1m Length
Reinforcement Deck
RECOMMENDED BY
RESIDENT ENGINEER
Total Quantity
CONTRACTOR'S
REPRESENTATIVE
CONSULTANT'S
TECHNICAL OFFICER
CHECKED BY
SITE ENGINEER
15400 mm
2
8160 mm
3
200 mm
300 mm
290 mm
4
540 mm
700 mm
100mm 200mm
5
100 mm
280 mm
500 mm
6
840 mm
290 mm
250 mm
290 mm
7
15400 mm
8
1000 mm
200 mm
9
1080 mm
250 mm 10
700 mm
12
400 mm
13
323.06
523.61
84.37
136.04
82.41
109.22
629.06
17.28
19.50
6.84
1931.39
NORTHERN ROADS REHABILITATION PROJECT
CONTRACTOR:
CATIC/MAGA
AGREED SITE MEASUREMENT RECORD
(To be Completed Daily )
Weight
(kg)
RECOMMENDED BY
RESIDENT ENGINEER

Вам также может понравиться