Sl. No.

3
4
5
6

10

11

12
13
14
15
16
17

Items

Description
Quantity : 2 Numers
Heat Duty : 100% RO Operation
Condenser
Cooling Water Inlet Temperature : 26 C
Temperature Rise : 7 C
Configuration : 2x100%,
Includes : Condenser Vacuum Pump + Separator
Condenser Vacuum System
Tank + Seal Water Recirculation Pump + Seal
Water Cooler
Condenser Flash Tank
Quantity : 2 Numbers
Condensate Extraction Pump
Configuration : 2x100%
Gland Steam Condenser
Quantity : 1 Number
Drain Cooler (External)
Quantity : 1 Number
LPH #1 : 1 Number
LPH #2 : 1 Number
Low Pressure Heater
LPH #3 : 1 Number
LPH #4 : 1 Number
Pneumatic Operated Control Valve
Capacity : 1x30% of BMCR
Deaerator Make-up Control Station Capacity : 1x100% of BMCR
Mototr Operated Valve
Capacity : 1x100% of BMCR
Quantity : 1 Number
Deaerator & Deaerator Storage
Deaerator Storage Tank Capacity : 263 m3
Tank
(effective storage)
Deaerator Recirculation Pump
Configuration : 1x100%
MDBFP
Capacity : 1x30% of BMCR
Boiler Feed Pump
TDBFP
Capacity : 2x50% of BMCR
HPH #6 : 1 Number
High Pressure Heater
HPH #7 : 1 Number
HPH #8 : 1 Number
Pneumatic Operated Control Valve
Capacity : 1x30% of BMCR
Mototr Operated Valve (On-Off Type)
Feed Control Station
Capacity : 1x100% of BMCR
Mototr Operated Valve (Inching Type)
Upstream of Feed Control Station
Capacity : 1x100% of BMCR
Capacity : 60% of BMCR
HP-LP Bypass Valve
HP Bypass Valve : 1 Number
LP Bypass Valve : 2 Numbers
Horizontal, Centrifugal
Force Draft Fan*
Configuration : 2x50%
Steam Air Heater
Quantity : 2 Numbers
Primary Air Fan*
Configuration : 2x50%
Seal Air Fan
Configuration : 2x100%
Coal Mills
Quantity : 6 Numbers

18

SCR

Type : Ammonia Injection System


Capacity : 100% BMCR Load Operation

19

ESP

Configuration : 2x50%

20

Induced Draft Fan*

Configuration : 2x50%

21

Flue Gas Desulfurization System

22

Chimney

23

Auxiliary Boiler

Design Margin is not available to us.

Note

Type : Lime Slurry System


Capacity : 100% BMCR Load Operation
Type : Twin Flue
Quantity : 1 Number
Quantity : 1 Number Common for Both Unit

The BFP discharge system up to feed control station is designed at BFP shut-off head
with stress reliving factor as indicated in ASME B31.1.