COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1139.9
0.0
0.0
1137.6
-0.5
-1.9
2
947.4
0.0
0.0
945.1
-20.0
-2.8
3
698.8
0.0
0.0
696.4
-2.1
2.0
4
913.5
0.0
0.0
911.2
16.9
-1.5
5
816.5
0.0
0.0
814.2
-12.0
-5.5
6
787.8
0.0
0.0
786.1
-0.6
-1.3
7
933.2
0.0
0.0
931.2
-7.6
-1.3
8
957.5
0.0
0.0
955.5
6.1
-1.8
9
970.2
0.0
0.0
968.2
-0.7
-7.2
10
920.5
0.0
0.0
918.5
-0.7
4.1
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1139.9
1139.9
M1 (kN.m)
-0.5
-17.1
0.0
M2 (kN.m)
-1.9
-13.1
-16.8
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.661
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
2.1 / 2.0 kN
As (Required): %2.51 1731.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.04 / 0.04 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-1

1C1

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
815.1
6.5
2.9
807.8
-12.9
-3.4
2
683.0
15.6
3.8
675.7
-25.3
-4.7
3
556.8
11.1
0.9
549.5
-21.3
-1.5
4
656.1
-2.5
2.5
648.8
0.7
-2.7
5
555.7
10.5
4.2
548.4
-13.3
-5.3
6
565.1
4.9
1.9
559.9
-9.5
-2.2
7
670.6
15.1
1.9
664.3
-20.2
-2.3
8
685.7
-3.4
2.7
679.4
-2.7
-3.1
9
691.0
5.9
11.6
684.7
-11.5
-11.7
10
665.2
5.8
-7.1
659.0
-11.4
6.4
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
815.1
815.1
M1 (kN.m)
-12.9
-12.2
0.0
M2 (kN.m)
-3.4
-9.4
-13.6
N-max (kN) 1124.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.473
Le1/b1 = 8.7 < 10
Beta =
0.45
Le2/b2 = 11.6 > 10 !!!
M-add(1/2)= 0.0 / 4.8 kN.m
Vd(x/y)=
0.2 / 0.8 kN
As (Required): %0.86 590.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17 804.2 mm2
v (x/y)= 0.00 / 0.01 N/mm2
Links = Y10-175

230

300
4Y25

2C1

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
415.7
14.1
3.3
408.4
-9.1
-3.0
2
347.1
25.7
5.4
339.8
-21.4
-5.3
3
293.0
27.9
1.7
285.7
-24.7
-1.8
4
340.5
3.3
2.3
333.2
-0.8
-1.8
5
290.5
14.3
6.0
283.2
-12.5
-5.8
6
288.9
10.7
2.2
283.7
-7.3
-1.9
7
343.9
17.2
2.3
337.7
-13.8
-2.1
8
349.4
8.5
2.8
343.2
-3.8
-2.6
9
350.9
12.9
7.4
344.6
-8.8
-7.3
10
342.5
12.8
-2.2
336.2
-8.8
2.7
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
415.7
415.7
M1 (kN.m)
14.1
6.2
23.8
M2 (kN.m)
3.3
4.8
0.0
N-max (kN) 1124.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.241
Le1/b1 = 8.7 < 10
Beta =
0.72
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 0.0 / 6.4 kN.m
Vd(x/y)= 16.7 / 3.8 kN
As (Required): %0.40 (min) 276.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17
804.2 mm2
v (x/y)= 0.29 / 0.07 N/mm2
Links = Y10-175

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-2

3C1

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
118.4
3.6
1.8
112.8
-5.3
-1.4
2
110.3
10.0
3.8
104.7
-8.8
-3.6
3
94.1
9.6
1.9
88.5
-9.4
-2.2
4
84.9
-1.4
0.7
79.3
-1.4
-0.5
5
80.4
4.7
3.6
74.8
-4.5
-3.0
6
82.1
2.9
1.1
78.1
-3.9
-0.9
7
98.0
4.6
1.3
93.2
-6.0
-1.0
8
98.9
2.3
1.4
94.1
-3.4
-1.1
9
99.0
3.5
2.5
94.2
-4.7
-2.4
10
98.0
3.4
0.1
93.2
-4.7
0.3
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
118.4
118.4
M1 (kN.m)
-5.3
-1.4
-10.2
M2 (kN.m)
1.8
1.4
0.0
N-max (kN) 931.6
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.090
Le1/b1 = 11.2 > 10 !!!
Beta =
0.89
Le2/b2 = 11.4 > 10 !!!
M-add(1/2)= 1.7 / 1.8 kN.m
Vd(x/y)=
6.1 / 0.1 kN
As (Required): %0.40 (min) 211.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52
804.2 mm2
v (x/y)= 0.14 / 0.00 N/mm2
Links = Y10-175

230

300
4Y16

4C1

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1042.0
0.0
0.0
1039.7
0.0
-1.8
2
803.3
0.0
0.0
801.0
12.7
-1.9
3
408.7
0.0
0.0
406.3
0.0
1.4
4
803.4
0.0
0.0
801.1
-12.6
-1.9
5
632.7
0.0
0.0
630.4
0.0
-6.4
6
707.2
0.0
0.0
705.5
0.0
-1.2
7
848.6
0.0
0.0
846.6
-9.0
-1.5
8
848.6
0.0
0.0
846.6
9.0
-1.5
9
870.4
0.0
0.0
868.4
0.0
-6.8
10
826.8
0.0
0.0
824.8
0.0
3.8
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1042.0
1042.0
M1 (kN.m)
0.0
15.6
0.0
M2 (kN.m)
-1.8
-12.0
-15.3
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.604
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
0.0 / 1.4 kN
As (Required): %1.99 1371.9 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.00 / 0.03 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-3

1C2

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
710.4
0.0
4.1
703.1
0.0
-6.0
2
548.8
-17.2
4.0
541.5
19.2
-5.7
3
274.3
0.0
2.9
267.0
0.0
-5.1
4
548.9
17.1
4.0
541.6
-19.2
-5.7
5
454.2
0.0
6.4
446.9
0.0
-9.1
6
481.7
0.0
2.8
476.5
0.0
-4.1
7
578.0
11.0
3.3
571.8
-10.9
-4.9
8
578.0
-11.0
3.3
571.8
10.9
-4.9
9
590.5
0.0
12.5
584.3
0.0
-13.8
10
565.5
-0.1
-5.9
559.3
0.0
4.1
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
710.4
710.4
M1 (kN.m)
0.0
-10.7
0.0
M2 (kN.m)
-6.0
-8.2
-16.0
N-max (kN) 1124.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.412
Le1/b1 = 9.0 < 10
Beta =
0.52
Le2/b2 = 11.6 > 10 !!!
M-add(1/2)= 0.0 / 6.0 kN.m
Vd(x/y)=
0.0 / 2.5 kN
As (Required): %0.40 279.3 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17 804.2 mm2
v (x/y)= 0.00 / 0.05 N/mm2
Links = Y10-175

230

300
4Y25

2C2

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y16

COLUMN REINFORCEMENT DESIGN

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-4

3C2

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
404.9
-0.1
8.2
397.6
0.2
-8.9
2
315.4
-26.1
7.6
308.1
26.3
-8.2
3
174.5
-0.1
7.7
167.2
0.1
-8.8
4
315.5
25.9
7.6
308.2
-26.0
-8.2
5
264.9
-0.1
12.4
257.6
0.1
-13.3
6
275.2
-0.1
5.5
270.0
0.1
-6.0
7
330.2
6.3
6.6
324.0
-6.5
-7.2
8
330.2
-6.6
6.6
324.0
6.8
-7.2
9
334.4
-0.1
11.4
328.1
0.1
-12.2
10
326.1
-0.1
1.8
319.8
0.2
-2.2
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
404.9
404.9
M1 (kN.m)
0.2
6.1
0.0
M2 (kN.m)
-8.9
-4.7
-18.3
N-max (kN) 1124.8
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.235
Le1/b1 = 8.9 < 10
Beta =
0.73
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 0.0 / 6.2 kN.m
Vd(x/y)= 16.6 / 5.3 kN
As (Required): %0.40 (min) 276.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17
804.2 mm2
v (x/y)= 0.28 / 0.09 N/mm2
Links = Y10-175
Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))
Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
66.6
-0.1
7.2
61.0
0.1
-7.0
2
58.8
-7.0
6.6
53.2
5.2
-6.4
3
46.1
-0.1
8.7
40.5
0.1
-9.8
4
58.8
6.8
6.6
53.2
-5.1
-6.5
5
59.5
-0.1
9.9
53.9
0.0
-8.9
6
46.5
-0.1
4.8
42.5
0.1
-4.7
7
55.8
1.4
5.8
51.0
-1.5
-5.7
8
55.8
-1.6
5.8
51.0
1.7
-5.7
9
56.3
-0.1
7.0
51.5
0.1
-7.0
10
55.2
-0.1
4.6
50.4
0.1
-4.4
Critical Combination:2 - ((G+Q)P11 *F)
Min Design
N (kN)
58.8
58.8
M1 (kN.m)
-7.0
-0.7
-15.0
M2 (kN.m)
6.6
0.7
0.0
N-max (kN) 931.6
Concrete Cover =30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.044
Le1/b1 = 11.4 > 10 !!!
Beta =
0.95
Le2/b2 = 11.4 > 10 !!!
M-add(1/2)= 0.9 / 0.9 kN.m
Vd(x/y)=
3.9 / 5.9 kN
As (Required): %0.64 339.2 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.09 / 0.14 N/mm2
Links = Y10-175

230

300
4Y16

4C2

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1139.4
0.0
0.0
1137.1
0.5
-2.0
2
913.3
0.0
0.0
910.9
-16.8
-1.5
3
698.2
0.0
0.0
695.9
2.2
2.0
4
947.1
0.0
0.0
944.8
20.0
-2.8
5
816.3
0.0
0.0
813.9
12.0
-5.5
6
787.4
0.0
0.0
785.8
0.6
-1.3
7
957.1
0.0
0.0
955.1
-6.1
-1.8
8
932.8
0.0
0.0
930.8
7.6
-1.3
9
969.7
0.0
0.0
967.7
0.7
-7.2
10
920.1
0.0
0.0
918.2
0.8
4.1
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1139.4
1139.4
M1 (kN.m)
0.5
17.1
0.0
M2 (kN.m)
-2.0
-13.1
-16.8
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.661
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
2.2 / 2.0 kN
As (Required): %2.51 1729.8 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.04 / 0.04 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-5

1C3

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
814.5
-6.5
2.9
807.2
13.0
-3.4
2
655.8
2.5
2.5
648.5
-0.6
-2.7
3
556.2
-11.2
0.9
548.9
21.3
-1.5
4
682.6
-15.7
3.8
675.3
25.3
-4.8
5
555.4
-10.6
4.2
548.1
13.3
-5.3
6
564.7
-4.9
1.9
559.5
9.6
-2.2
7
685.2
3.3
2.7
678.9
2.8
-3.1
8
670.1
-15.1
1.9
663.8
20.2
-2.3
9
690.5
-5.9
11.6
684.2
11.5
-11.7
10
664.8
-5.9
-7.0
658.5
11.5
6.3
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
814.5
814.5
M1 (kN.m)
13.0
12.2
18.8
M2 (kN.m)
-3.4
-9.4
0.0
N-max (kN) 1124.8
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.472
Le1/b1 = 8.7 < 10
Beta =
0.45
Le2/b2 = 11.6 > 10 !!!
M-add(1/2)= 0.0 / 4.8 kN.m
Vd(x/y)=
0.2 / 0.8 kN
As (Required): %0.84 579.4 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17 804.2 mm2
v (x/y)= 0.00 / 0.01 N/mm2
Links = Y10-175

230

300
4Y25

2C3

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
415.3
-14.3
3.1
408.0
9.1
-2.9
2
340.4
-3.4
2.1
333.1
0.8
-1.7
3
292.5
-28.0
1.5
285.2
24.7
-1.7
4
346.7
-25.8
5.3
339.4
21.3
-5.2
5
290.3
-14.3
5.9
283.0
12.5
-5.8
6
288.6
-10.8
2.0
283.3
7.3
-1.8
7
349.0
-8.6
2.7
342.8
3.8
-2.5
8
343.5
-17.3
2.2
337.3
13.8
-1.9
9
350.5
-12.9
7.2
344.2
8.8
-7.2
10
342.1
-13.0
-2.3
335.8
8.8
2.8
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
415.3
415.3
M1 (kN.m)
-14.3
-6.2
-23.8
M2 (kN.m)
3.1
4.8
0.0
N-max (kN) 1124.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.241
Le1/b1 = 8.7 < 10
Beta =
0.72
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 0.0 / 6.3 kN.m
Vd(x/y)= 16.7 / 3.7 kN
As (Required): %0.40 (min) 276.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17
804.2 mm2
v (x/y)= 0.29 / 0.07 N/mm2
Links = Y10-175

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-6

3C3

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
118.5
-3.7
1.7
112.9
5.4
-1.3
2
84.9
1.3
0.7
79.3
1.5
-0.4
3
94.2
-9.7
1.8
88.6
9.5
-2.1
4
110.5
-10.0
3.8
104.9
8.8
-3.5
5
80.5
-4.8
3.6
74.9
4.6
-2.9
6
82.1
-2.9
1.0
78.1
4.0
-0.8
7
99.0
-2.4
1.3
94.2
3.5
-1.0
8
98.1
-4.6
1.2
93.3
6.1
-0.9
9
99.0
-3.5
2.5
94.2
4.8
-2.3
10
98.1
-3.5
0.0
93.3
4.8
0.4
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
118.5
118.5
M1 (kN.m)
5.4
1.4
10.2
M2 (kN.m)
1.7
1.4
0.0
N-max (kN) 931.6
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.090
Le1/b1 = 11.2 > 10 !!!
Beta =
0.89
Le2/b2 = 11.4 > 10 !!!
M-add(1/2)= 1.7 / 1.8 kN.m
Vd(x/y)=
6.1 / 2.1 kN
As (Required): %0.40 (min) 211.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52
804.2 mm2
v (x/y)= 0.15 / 0.05 N/mm2
Links = Y10-175

230

300
4Y16

4C3

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1696.6
0.0
0.0
1693.2
-12.7
-13.6
2
1567.2
0.0
0.0
1563.7
-39.9
-15.4
3
1308.0
0.0
0.0
1304.6
-21.4
-21.1
4
1323.1
0.0
0.0
1319.7
16.9
-11.9
5
1161.4
0.0
0.0
1157.9
-19.6
2.8
6
1154.8
0.0
0.0
1152.3
-9.3
-9.1
7
1366.8
0.0
0.0
1363.8
-19.2
-9.7
8
1404.7
0.0
0.0
1401.7
-3.0
-12.1
9
1378.3
0.0
0.0
1375.3
-11.1
-35.2
10
1393.1
0.0
0.0
1390.1
-11.1
13.4
Critical Combination:2 - ((G+Q)P11 *F)
Min
Design
N (kN)
1567.2
1567.2
M1 (kN.m)
-39.9
-18.0
-44.1
M2 (kN.m)
-15.4
-31.3
0.0
N-max (kN) 2691.1
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.606
Le1/b1 = 2.2 < 10
Beta =
0.30
Le2/b2 = 1.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)= 19.6 / 9.1 kN
As (Required): %2.86 2955.4 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %3.79 3927.0 mm2
v (x/y)= 0.25 / 0.10 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-7

1C4

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
917.5
-6.6
6.2
910.2
18.9
-7.7
2
921.3
-3.5
6.5
914.0
20.6
-8.2
3
799.3
-4.1
9.1
792.0
17.7
-11.3
4
672.5
-3.8
5.9
665.1
4.2
-7.3
5
706.1
-4.6
-0.8
698.8
18.0
0.5
6
625.3
-4.2
4.1
620.1
12.5
-5.2
7
741.8
1.7
4.3
735.6
8.3
-5.6
8
758.9
-11.7
5.6
752.7
21.8
-6.8
9
747.0
-5.0
20.2
740.7
15.1
-21.5
10
753.8
-5.0
-10.3
747.5
15.0
9.1
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
917.5
917.5
M1 (kN.m)
18.9
10.6
30.2
M2 (kN.m)
-7.7
-13.8
0.0
N-max (kN) 1552.5
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.532
Le1/b1 = 11.6 > 10 !!!
Beta =
0.38
Le2/b2 = 9.2 < 10
M-add(1/2)= 7.4 / 0.0 kN.m
Vd(x/y)=
2.1 / 3.0 kN
As (Required): %2.20 1520.3 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.04 / 0.05 N/mm2
Links = Y10-300

450

230
8Y25

2C4

Project: COSMOPOLITAN_WOMENS_CLUB

300

230
4Y25

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
499.0
-31.5
9.7
491.7
31.9
-10.7
2
496.2
-40.6
10.4
488.9
40.9
-11.5
3
433.7
-31.4
13.2
426.4
31.7
-14.2
4
371.2
-2.1
9.1
363.9
2.2
-9.9
5
380.7
-31.4
0.2
373.4
31.8
-0.7
6
341.1
-21.0
6.5
335.9
21.3
-7.2
7
406.4
-21.2
7.4
400.1
21.5
-8.2
8
412.3
-29.3
8.2
406.0
29.6
-9.1
9
408.6
-25.3
16.4
402.3
25.6
-17.5
10
410.0
-25.2
-0.8
403.8
25.5
0.3
Critical Combination:2 - ((G+Q)P11 *F)
Min Design
N (kN)
496.2
496.2
M1 (kN.m)
40.9
5.7
53.8
M2 (kN.m)
-11.5
-7.4
0.0
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.288
Le1/b1 = 11.8 > 10 !!!
Beta =
0.66
Le2/b2 = 8.8 < 10
M-add(1/2)= 7.5 / 0.0 kN.m
Vd(x/y)= 20.1 / 0.3 kN
As (Required): %2.54 1752.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.38 / 0.00 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-8

3C4

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
87.6
-18.1
4.1
82.0
11.4
-2.9
2
79.8
-20.5
4.6
74.2
12.5
-3.4
3
71.7
-18.0
5.4
66.1
11.2
-3.9
4
76.7
-4.2
3.7
71.1
3.2
-2.5
5
65.6
-18.0
0.4
60.0
11.3
-0.4
6
61.5
-12.1
2.8
57.5
7.6
-2.0
7
73.4
-13.1
3.3
68.6
7.7
-2.3
8
74.1
-16.0
3.4
69.4
10.6
-2.4
9
73.9
-14.6
4.7
69.1
9.2
-3.9
10
73.6
-14.5
1.9
68.8
9.2
-0.8
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
87.6
87.6
M1 (kN.m) -18.1
-1.0
-24.5
M2 (kN.m)
4.1
1.0
0.0
N-max (kN) 931.6
Concrete Cover =30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.066
Le1/b1 = 11.6 > 10 !!!
Beta =
0.92
Le2/b2 = 11.3 > 10 !!!
M-add(1/2)= 1.4 / 1.3 kN.m
Vd(x/y)= 10.5 / 3.0 kN
As (Required): %1.25 659.2 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.25 / 0.07 N/mm2
Links = Y10-175

300

230
4Y25

4C4

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
2554.9
0.0
0.0
2550.3
0.1
-11.0
2
2088.5
0.0
0.0
2083.9
104.5
-11.0
3
1991.0
0.0
0.0
1986.4
0.0
-14.5
4
2088.6
0.0
0.0
2084.0
-104.4
-11.0
5
1795.5
0.0
0.0
1790.8
0.0
-0.9
6
1721.4
0.0
0.0
1718.1
0.0
-7.4
7
2065.7
0.0
0.0
2061.7
-29.1
-8.8
8
2065.7
0.0
0.0
2061.7
29.2
-8.8
9
2059.2
0.0
0.0
2055.2
0.0
-20.0
10
2072.2
0.0
0.0
2068.2
0.0
2.3
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
2554.9
2554.9
M1 (kN.m)
0.1
51.1
0.0
M2 (kN.m)
-11.0
-29.4
-34.4
N-max (kN) 3467.3
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.741
Le1/b1 = 1.0 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
0.0 / 7.4 kN
As (Required): %3.15 4344.4 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %3.56 4908.7 mm2
v (x/y)= 0.00 / 0.07 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-9

1C5

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1808.0
0.0
9.4
1797.0
-0.1
-11.9
2
1473.4
-19.5
9.3
1462.5
-19.3
-11.7
3
1615.5
0.0
12.9
1604.5
-0.1
-16.5
4
1473.5
19.5
9.4
1462.5
19.2
-11.7
5
1486.4
0.0
0.3
1475.5
0.0
-0.6
6
1220.2
0.0
6.3
1212.4
-0.1
-7.9
7
1464.2
25.9
7.5
1454.8
-24.6
-9.5
8
1464.2
-25.9
7.5
1454.8
24.5
-9.5
9
1460.8
0.0
21.7
1451.4
-0.1
-23.5
10
1467.7
0.0
-6.7
1458.3
-0.1
4.5
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1808.0
1808.0
M1 (kN.m)
-0.1
-36.2
0.0
M2 (kN.m)
-11.9
-20.8
-25.6
N-max (kN) 2328.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.699
Le1/b1 = 7.5 < 10
Beta =
0.30
Le2/b2 = 11.6 > 10 !!!
M-add(1/2)= 0.0 / 6.8 kN.m
Vd(x/y)=
0.1 / 4.5 kN
As (Required): %2.82 2920.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 2945.2 mm2
v (x/y)= 0.00 / 0.06 N/mm2
Links = Y10-300

230

600

10Y25

2C5

Project: COSMOPOLITAN_WOMENS_CLUB

230

450
6Y25

COLUMN REINFORCEMENT DESIGN

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-10

3C5

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
950.6
-0.5
14.3
939.6
0.5
-15.0
2
778.9
41.8
14.2
767.9
-44.6
-14.8
3
839.2
-0.4
20.0
828.2
0.4
-21.0
4
778.9
-42.6
14.2
768.0
45.4
-14.9
5
776.5
-0.2
1.0
765.5
0.2
-1.2
6
643.1
-0.4
9.6
635.3
0.3
-10.1
7
771.7
11.0
11.5
762.3
-14.3
-12.1
8
771.7
-11.8
11.5
762.3
15.1
-12.1
9
770.8
-0.4
19.4
761.5
0.4
-20.2
10
772.6
-0.4
3.7
763.2
0.4
-4.0
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
950.6
950.6
M1 (kN.m)
-0.5
-19.0
0.0
M2 (kN.m)
-15.0
-10.9
-29.6
N-max (kN) 1687.2
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.367
Le1/b1 = 6.6 < 10
Beta =
0.57
Le2/b2 = 11.4 > 10 !!!
M-add(1/2)= 0.0 / 9.7 kN.m
Vd(x/y)= 27.9 / 6.2 kN
As (Required): %0.40 (min) 414.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17
1206.4 mm2
v (x/y)= 0.30 / 0.08 N/mm2
Links = Y10-175
Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))
Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
98.2
-0.1
6.2
92.6
0.1
-4.4
2
88.4
6.5
6.1
82.8
-3.1
-4.3
3
73.5
-0.1
8.8
67.9
0.1
-6.3
4
88.4
-6.6
6.2
82.8
3.2
-4.3
5
76.6
0.0
0.9
71.0
0.0
-1.1
6
69.4
-0.1
4.2
65.4
0.1
-3.0
7
83.3
1.0
5.0
78.5
-1.3
-3.6
8
83.3
-1.2
5.0
78.5
1.5
-3.6
9
83.3
-0.1
6.5
78.5
0.1
-5.1
10
83.2
-0.1
3.6
78.4
0.1
-2.0
Critical Combination:2 - ((G+Q)P11 *F)
Min Design
N (kN)
88.4
88.4
M1 (kN.m)
6.5
1.0
14.8
M2 (kN.m)
6.1
1.0
0.0
N-max (kN) 931.6
Concrete Cover =30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.067
Le1/b1 = 11.8 > 10 !!!
Beta =
0.92
Le2/b2 = 11.3 > 10 !!!
M-add(1/2)= 1.4 / 1.3 kN.m
Vd(x/y)=
3.1 / 4.8 kN
As (Required): %0.47 246.3 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.07 / 0.11 N/mm2
Links = Y10-175

230

450
6Y16

4C5

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1693.0
0.0
0.0
1689.5
12.7
-13.5
2
1320.3
0.0
0.0
1316.8
-16.9
-11.8
3
1304.8
0.0
0.0
1301.3
21.4
-21.1
4
1563.6
0.0
0.0
1560.1
39.9
-15.3
5
1159.7
0.0
0.0
1156.3
19.6
2.8
6
1152.3
0.0
0.0
1149.8
9.3
-9.0
7
1401.7
0.0
0.0
1398.7
3.0
-12.0
8
1363.7
0.0
0.0
1360.8
19.2
-9.6
9
1375.4
0.0
0.0
1372.4
11.1
-35.0
10
1390.1
0.0
0.0
1387.1
11.1
13.3
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1693.0
1693.0
M1 (kN.m)
12.7
19.5
24.0
M2 (kN.m)
-13.5
-33.9
0.0
N-max (kN) 2328.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.654
Le1/b1 = 2.2 < 10
Beta =
0.30
Le2/b2 = 1.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)= 19.6 / 9.0 kN
As (Required): %2.42 2500.7 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 2945.2 mm2
v (x/y)= 0.25 / 0.10 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-11

1C6

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
914.1
6.6
6.1
906.8
-18.9
-7.7
2
669.8
3.7
5.9
662.5
-4.2
-7.3
3
796.3
4.1
9.1
789.0
-17.7
-11.2
4
918.0
3.5
6.5
910.7
-20.6
-8.1
5
704.6
4.6
-0.8
697.3
-18.0
0.5
6
623.0
4.2
4.1
617.8
-12.5
-5.1
7
756.1
11.7
5.6
749.9
-21.8
-6.8
8
739.1
-1.7
4.3
732.8
-8.3
-5.5
9
744.2
5.0
20.1
738.0
-15.0
-21.4
10
750.9
5.0
-10.2
744.7
-15.0
9.0
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
914.1
914.1
M1 (kN.m)
-18.9
-10.5
-30.2
M2 (kN.m)
-7.7
-13.7
0.0
N-max (kN) 1552.5
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.530
Le1/b1 = 11.6 > 10 !!!
Beta =
0.38
Le2/b2 = 9.2 < 10
M-add(1/2)= 7.5 / 0.0 kN.m
Vd(x/y)=
2.1 / 2.9 kN
As (Required): %2.19 1510.3 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.04 / 0.05 N/mm2
Links = Y10-300

450

230
6Y25

2C6

Project: COSMOPOLITAN_WOMENS_CLUB

300

230
4Y25

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
496.0
31.2
9.1
488.7
-31.6
-10.0
2
368.7
1.9
8.6
361.4
-2.0
-9.4
3
430.9
31.2
12.8
423.6
-31.5
-13.6
4
493.3
40.4
10.0
486.0
-40.7
-10.9
5
379.3
31.3
-0.1
372.0
-31.7
-0.4
6
339.0
20.9
6.1
333.8
-21.1
-6.7
7
409.8
29.1
7.8
403.5
-29.4
-8.5
8
403.9
21.0
6.9
397.6
-21.3
-7.6
9
406.1
25.1
15.9
399.9
-25.4
-16.9
10
407.5
25.0
-1.2
401.3
-25.3
0.8
Critical Combination:4 - ((G+Q)P21 *F)
Min Design
N (kN)
493.3
493.3
M1 (kN.m)
-40.7
-5.7
-53.3
M2 (kN.m)
-10.9
-7.4
0.0
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.286
Le1/b1 = 11.8 > 10 !!!
Beta =
0.67
Le2/b2 = 8.8 < 10
M-add(1/2)= 7.4 / 0.0 kN.m
Vd(x/y)= 20.0 / 0.1 kN
As (Required): %2.50 1723.3 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.38 / 0.00 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-12

3C6

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
87.2
17.9
3.8
81.6
-11.2
-2.6
2
76.5
4.0
3.4
70.9
-3.0
-2.3
3
71.4
17.8
5.2
65.8
-11.0
-3.6
4
79.4
20.3
4.3
73.8
-12.4
-3.2
5
65.4
17.9
0.3
59.8
-11.2
-0.3
6
61.2
12.0
2.6
57.2
-7.5
-1.8
7
73.8
15.8
3.1
69.0
-10.5
-2.2
8
73.0
12.9
3.0
68.2
-7.5
-2.1
9
73.6
14.4
4.5
68.8
-9.0
-3.6
10
73.2
14.4
1.7
68.4
-9.0
-0.6
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
87.2
87.2
M1 (kN.m)
17.9
1.0
23.9
M2 (kN.m)
3.8
1.0
0.0
N-max (kN) 931.6
Concrete Cover =30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.066
Le1/b1 = 11.6 > 10 !!!
Beta =
0.92
Le2/b2 = 11.3 > 10 !!!
M-add(1/2)= 1.3 / 1.3 kN.m
Vd(x/y)= 10.4 / 2.8 kN
As (Required): %1.21 639.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.25 / 0.07 N/mm2
Links = Y10-175

300

230
4Y25

4C6

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1439.2
0.0
0.0
1436.9
-0.3
13.1
2
1213.0
0.0
0.0
1210.7
-21.0
13.2
3
1148.2
0.0
0.0
1145.9
-13.4
15.3
4
1180.2
0.0
0.0
1177.8
17.7
13.4
5
738.6
0.0
0.0
736.3
-3.3
3.6
6
990.0
0.0
0.0
988.4
-0.6
8.7
7
1176.5
0.0
0.0
1174.5
-7.9
10.8
8
1199.6
0.0
0.0
1197.6
6.6
10.2
9
1170.6
0.0
0.0
1168.6
-0.6
5.0
10
1205.5
0.0
0.0
1203.5
-0.7
16.0
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1439.2
1439.2
M1 (kN.m)
-0.3
-21.6
0.0
M2 (kN.m)
13.1
16.6
21.2
N-max (kN) 1914.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.834
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
3.3 / 3.6 kN
As (Required): %4.10 2829.7 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %4.27 2945.2 mm2
v (x/y)= 0.06 / 0.07 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-13

1C7

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1046.2
5.1
-9.0
1038.9
-10.3
10.7
2
891.9
15.8
-9.6
884.6
-24.6
11.7
3
837.8
15.5
-10.3
830.5
-22.4
12.3
4
854.0
-4.3
-8.9
846.7
3.5
10.4
5
557.5
6.6
-3.8
550.2
-11.2
5.0
6
721.6
4.0
-6.0
716.4
-7.8
7.1
7
858.8
14.8
-7.6
852.5
-18.9
8.9
8
873.1
-5.2
-6.9
866.8
0.1
8.2
9
856.4
4.8
2.0
850.2
-9.4
-0.3
10
875.4
4.9
-16.4
869.1
-9.4
17.4
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1046.2
1046.2
M1 (kN.m)
-10.3
-15.7
0.0
M2 (kN.m)
10.7
12.0
20.7
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.606
Le1/b1 = 8.7 < 10
Beta =
0.30
Le2/b2 = 11.8 > 10 !!!
M-add(1/2)= 0.0 / 6.6 kN.m
Vd(x/y)=
5.6 / 2.8 kN
As (Required): %2.21 1521.5 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.10 / 0.05 N/mm2
Links = Y10-300

230

300
6Y25

2C7

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y25

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
584.0
15.2
-12.8
576.7
-15.6
13.0
2
502.9
29.5
-14.4
495.6
-30.9
14.8
3
471.9
29.9
-15.2
464.6
-31.2
15.5
4
472.7
1.3
-12.2
465.4
-0.9
12.3
5
316.7
16.0
-6.6
309.4
-16.7
7.0
6
403.1
11.5
-8.5
397.9
-11.8
8.6
7
481.1
18.7
-10.4
474.9
-19.7
10.6
8
486.3
9.0
-10.0
480.1
-8.7
10.1
9
480.3
13.8
-5.5
474.0
-14.2
5.4
10
487.2
13.9
-14.9
480.9
-14.2
15.3
Critical Combination:2 - ((G+Q)P11 *F)
Min Design
N (kN)
502.9
502.9
M1 (kN.m)
-30.9
-7.5
-50.7
M2 (kN.m)
14.8
5.8
0.0
N-max (kN) 1124.8
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.292
Le1/b1 = 8.7 < 10
Beta =
0.66
Le2/b2 = 11.7 > 10 !!!
M-add(1/2)= 0.0 / 7.0 kN.m
Vd(x/y)= 10.4 / 4.3 kN
As (Required): %1.09 750.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17 804.2 mm2
v (x/y)= 0.18 / 0.08 N/mm2
Links = Y10-175

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-14

3C7

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
126.1
7.2
-6.8
120.5
-7.2
3.4
2
116.6
14.4
-8.3
111.0
-10.8
5.0
3
108.4
12.9
-8.6
102.8
-11.1
5.1
4
93.8
-0.6
-6.3
88.2
-1.9
2.9
5
75.9
6.9
-4.6
70.3
-5.8
3.5
6
87.5
5.4
-4.5
83.5
-5.2
2.2
7
104.5
7.6
-5.4
99.7
-7.6
2.6
8
105.4
5.3
-5.4
100.6
-4.9
2.6
9
104.3
6.4
-4.1
99.5
-6.3
1.2
10
105.7
6.5
-6.7
100.9
-6.3
4.0
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
126.1
126.1
M1 (kN.m)
7.2
1.4
16.7
M2 (kN.m)
-6.8
-1.4
0.0
N-max (kN) 931.6
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.095
Le1/b1 = 11.2 > 10 !!!
Beta =
0.89
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 1.8 / 1.9 kN.m
Vd(x/y)=
8.0 / 4.4 kN
As (Required): %0.43 227.5 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.19 / 0.10 N/mm2
Links = Y10-175

230

300
4Y16

4C7

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1365.3
0.0
0.0
1363.0
0.0
17.6
2
1100.5
0.0
0.0
1098.1
15.2
17.7
3
810.1
0.0
0.0
807.8
0.0
20.8
4
1101.5
0.0
0.0
1099.2
-15.2
17.7
5
574.6
0.0
0.0
572.3
0.0
5.6
6
922.4
0.0
0.0
920.7
0.0
11.8
7
1106.8
0.0
0.0
1104.8
-9.7
14.1
8
1106.8
0.0
0.0
1104.8
9.7
14.1
9
1091.4
0.0
0.0
1089.4
0.0
9.0
10
1122.2
0.0
0.0
1120.3
0.0
19.2
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1365.3
1365.3
M1 (kN.m)
0.0
-20.5
0.0
M2 (kN.m)
17.6
15.7
22.0
N-max (kN) 1914.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.792
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
0.0 / 5.6 kN
As (Required): %3.82 2634.0 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %4.27 2945.2 mm2
v (x/y)= 0.00 / 0.11 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-15

1C8

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
921.3
0.1
-14.1
913.9
-0.2
17.9
2
743.4
-18.6
-14.0
736.0
20.8
17.7
3
554.0
0.1
-16.5
546.7
-0.1
21.2
4
744.5
18.7
-14.0
737.2
-21.0
17.7
5
394.7
0.0
-6.4
387.4
-0.1
8.8
6
622.1
0.1
-9.4
616.9
-0.1
12.0
7
746.5
12.0
-11.3
740.3
-12.0
14.4
8
746.5
-11.9
-11.3
740.3
11.7
14.4
9
737.4
0.0
-2.3
731.1
-0.1
5.7
10
755.7
0.1
-20.3
749.4
-0.2
23.1
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
921.3
921.3
M1 (kN.m)
-0.2
-13.8
0.0
M2 (kN.m)
17.9
10.6
29.3
N-max (kN) 1552.5
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.534
Le1/b1 = 9.0 < 10
Beta =
0.38
Le2/b2 = 11.8 > 10 !!!
M-add(1/2)= 0.0 / 7.6 kN.m
Vd(x/y)=
0.0 / 4.8 kN
As (Required): %2.23 1539.9 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.00 / 0.09 N/mm2
Links = Y10-300

230

300
6Y25

2C8

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y25

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
500.4
-0.4
-22.8
493.1
0.8
23.6
2
405.9
-28.9
-22.4
398.6
30.0
23.1
3
308.2
-0.4
-27.6
300.9
0.6
28.8
4
407.3
28.2
-22.3
400.0
-28.9
23.1
5
226.5
-0.2
-12.2
219.2
0.3
13.1
6
338.8
-0.3
-15.3
333.6
0.5
15.8
7
406.5
6.7
-18.3
400.3
-6.6
19.0
8
406.5
-7.5
-18.3
400.3
7.9
19.0
9
403.2
-0.4
-13.7
396.9
0.7
14.1
10
409.9
-0.3
-23.0
403.6
0.6
23.9
Critical Combination:2 - ((G+Q)P11 *F)
Min Design
N (kN)
405.9
405.9
M1 (kN.m)
30.0
6.1
0.0
M2 (kN.m)
23.1
4.7
45.2
N-max (kN) 1291.7
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.235
Le1/b1 = 8.9 < 10
Beta =
0.73
Le2/b2 = 11.7 > 10 !!!
M-add(1/2)= 0.0 / 6.4 kN.m
Vd(x/y)= 18.7 / 17.9 kN
As (Required): %1.61 1109.8 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.82 1256.6 mm2
v (x/y)= 0.33 / 0.33 N/mm2
Links = Y10-225

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-16

3C8

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
72.5
-0.3
-14.3
66.9
0.2
9.8
2
64.7
-8.5
-13.8
59.1
6.0
9.2
3
56.4
-0.3
-18.3
50.8
0.2
13.6
4
64.4
8.0
-13.8
58.8
-5.7
9.2
5
53.3
-0.2
-9.9
47.7
0.1
9.0
6
50.7
-0.2
-9.6
46.7
0.1
6.6
7
60.9
1.3
-11.5
56.1
-1.5
7.9
8
60.9
-1.9
-11.5
56.1
1.8
7.9
9
60.2
-0.3
-10.2
55.4
0.2
6.5
10
61.5
-0.3
-12.8
56.7
0.2
9.3
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
72.5
72.5
M1 (kN.m)
-0.3
-0.8
0.0
M2 (kN.m) -14.3
-0.8
-16.7
N-max (kN) 931.6
Concrete Cover =30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.055
Le1/b1 = 11.4 > 10 !!!
Beta =
0.93
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 1.1 / 1.1 kN.m
Vd(x/y)= 4.6 / 10.2 kN
As (Required): %0.70 372.7 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52 804.2 mm2
v (x/y)= 0.11 / 0.24 N/mm2
Links = Y10-175

230

300
4Y20

4C8

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16

COLUMN REINFORCEMENT DESIGN

Storey: 1 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1417.0
0.0
0.0
1414.7
0.2
13.1
2
1166.6
0.0
0.0
1164.3
-17.7
13.5
3
1130.4
0.0
0.0
1128.0
13.4
15.3
4
1190.9
0.0
0.0
1188.6
20.9
13.3
5
728.4
0.0
0.0
726.0
3.2
3.6
6
974.9
0.0
0.0
973.2
0.5
8.8
7
1181.4
0.0
0.0
1179.4
-6.6
10.3
8
1158.3
0.0
0.0
1156.3
7.9
10.8
9
1152.5
0.0
0.0
1150.5
0.6
5.1
10
1187.3
0.0
0.0
1185.3
0.6
16.0
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1417.0
1417.0
M1 (kN.m)
0.2
21.3
0.0
M2 (kN.m)
13.1
16.3
20.9
N-max (kN) 1914.8
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Short Column...
N/bhFcu = 0.821
Le1/b1 = 1.7 < 10
Beta =
0.30
Le2/b2 = 2.2 < 10
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(x/y)=
3.2 / 3.6 kN
As (Required): %3.98 2748.5 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %4.27 2945.2 mm2
v (x/y)= 0.06 / 0.07 N/mm2
Links = Y10-300

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-17

1C9

Storey: 2 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
1023.9
-5.2
-9.1
1016.6
10.4
10.8
2
840.4
4.3
-8.9
833.1
-3.4
10.4
3
819.8
-15.5
-10.4
812.5
22.4
12.4
4
869.6
-15.8
-9.7
862.3
24.7
11.8
5
547.2
-6.6
-3.8
539.9
11.2
5.0
6
706.4
-4.0
-6.1
701.1
7.9
7.2
7
854.8
5.1
-6.9
848.5
0.0
8.3
8
840.5
-14.9
-7.7
834.2
18.9
9.0
9
838.2
-4.9
1.9
831.9
9.5
-0.2
10
857.1
-4.8
-16.5
850.8
9.4
17.5
Critical Combination:1 - (G+Q *F)
Min
Design
N (kN)
1023.9
1023.9
M1 (kN.m)
10.4
15.4
0.0
M2 (kN.m)
10.8
11.8
21.0
N-max (kN) 1552.5
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.594
Le1/b1 = 8.7 < 10
Beta =
0.31
Le2/b2 = 11.8 > 10 !!!
M-add(1/2)= 0.0 / 6.8 kN.m
Vd(x/y)=
5.6 / 2.8 kN
As (Required): %2.07 1430.9 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %2.85 1963.5 mm2
v (x/y)= 0.10 / 0.05 N/mm2
Links = Y10-300

230

300
6Y25

2C9

Project: COSMOPOLITAN_WOMENS_CLUB

230

300
4Y25

COLUMN REINFORCEMENT DESIGN

Storey: 3 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
561.4
-14.5
-13.0
554.1
13.2
13.0
2
459.1
-1.1
-12.3
451.8
-0.2
12.3
3
453.7
-29.3
-15.3
446.4
29.2
15.5
4
480.1
-28.6
-14.6
472.8
28.4
14.8
5
306.3
-15.7
-6.7
299.0
15.6
7.0
6
387.6
-11.0
-8.7
382.4
10.2
8.7
7
467.8
-8.4
-10.2
461.5
6.7
10.2
8
462.6
-18.0
-10.6
456.3
17.7
10.7
9
461.7
-13.2
-5.8
455.5
12.2
5.5
10
468.6
-13.2
-15.0
462.3
12.2
15.4
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
561.4
561.4
M1 (kN.m)
-14.5
-8.4
0.0
M2 (kN.m)
13.0
6.5
26.5
N-max (kN) 1124.8
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.325
Le1/b1 = 8.7 < 10
Beta =
0.62
Le2/b2 = 11.7 > 10 !!!
M-add(1/2)= 0.0 / 7.0 kN.m
Vd(x/y)=
9.9 / 4.4 kN
As (Required): %0.59 407.2 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.17 804.2 mm2
v (x/y)= 0.17 / 0.08 N/mm2
Links = Y10-175

Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: CD-18

3C9

Storey: 4 (Con.:C20/25 / Steel:Grade 410 (Type 2))


Loadings (Combination):
No
N (bot)
M1 (bot)
M2 (bot)
N (top)
M1 (top)
M2 (top)
1
126.4
-6.1
-6.8
120.8
6.7
3.6
2
93.8
1.1
-6.3
88.2
1.8
3.0
3
108.6
-12.0
-8.6
103.0
10.7
5.3
4
117.0
-13.3
-8.4
111.4
10.3
5.2
5
76.0
-6.3
-4.6
70.4
5.6
3.6
6
87.7
-4.6
-4.5
83.7
4.9
2.3
7
105.7
-4.4
-5.4
100.9
4.6
2.8
8
104.8
-6.7
-5.4
100.0
7.3
2.8
9
104.6
-5.5
-4.1
99.8
5.9
1.3
10
105.9
-5.5
-6.7
101.1
5.9
4.2
Critical Combination:1 - (G+Q *F)
Min Design
N (kN)
126.4
126.4
M1 (kN.m)
6.7
1.5
0.0
M2 (kN.m)
-6.8
-1.5
-16.3
N-max (kN) 931.6
Concrete Cover = 30.0 mm
BS8110-Cl.3.8.4.5
Slender Column...
N/bhFcu = 0.096
Le1/b1 = 11.2 > 10 !!!
Beta =
0.89
Le2/b2 = 11.5 > 10 !!!
M-add(1/2)= 1.8 / 1.9 kN.m
Vd(x/y)=
7.5 / 4.4 kN
As (Required): %0.40 (min) 211.6 mm2
vc'(x/y)= 0.00 / 0.00 N/mm2
As (Provided): %1.52
804.2 mm2
v (x/y)= 0.18 / 0.11 N/mm2
Links = Y10-175

230

300
4Y16

4C9

Project: COSMOPOLITAN_WOMENS_CLUB

230

230
4Y16