Вы находитесь на странице: 1из 2

Tramo Q mx. (Lps) Coef. Sim. Q mx. prob.

(Lps) Dimetro (m)


A-B
1.05
0.4082
0.4286
0.0254
B-C
0.85
0.4082
0.3470
0.0268
C-D
0.51
0.5
0.2550
0.0268
D-E
0.34
0.7071
0.2404
0.0206
E - Re
0.17
1
0.1700
0.0206
E-F
0.17
1
0.1700
0.0206
F - Wc1
0.1
1
0.1000
0.0206
F - Lv1
0.07
1
0.0700
0.0206
D-G
0.17
1
0.1700
0.0268
G - Wc2
0.1
1
0.1000
0.0144
G - Lv2
0.07
1
0.0700
0.0144
C-H
0.34
1
0.3400
0.0268
H - Ld
0.2
1
0.2000
0.0268
H - Fr
0.14
1
0.1400
0.0206

Mueble Presin (mca)


Wc
3.5
Lv
3.5
Ld
3.5
Re
2.1
Fr
3.5

Instalacin hidrulica Agua Fra


Longitud (m) Accesorios
3 TSL (1.7), Ve (0.2), TPD (0.4), E (0.3)
2.5 TSB (1.7)
13.5 C90 (0.7), TSB (1.7)
0.5 TPD (0.4)
1.5 2C90 (1.2), TSL (1.4), Ve (0.1)
1 TSL (1.4)
2.5 C90 (0.6)
3.4 2C90 (1.2)
5 TPD (0.5)
2.5 C90 (0.4)
4.4 3C90 (1.2)
1.5 TPD (0.5)
1.95 C90 (0.7)
6.4 3C90(1.8)

Long. Equiv. (m) Long. T (m) hf (mca)


2.6
5.6
1.7
4.2
2.4
15.9
0.4
0.9
2.7
4.2
1.4
2.4
0.6
3.1
1.2
4.6
0.5
5.5
0.4
2.9
1.2
5.6
0.5
2
0.7
2.65
1.8
8.2

0.1606
0.0603
0.1234
0.0231
0.0540
0.0309
0.0138
0.0100
0.0190
0.0773
0.0731
0.0276
0.0127
0.0715

La norma establece una serie de presiones minimas para muebles hidrulicos, enunciadas a continuacin:
Utilizando la frmula CD = CDT - (H mueble + hf mueble)
Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249
2.5786
Para Wc1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756
3.5879
Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884
3.4917
Para Wc2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639
3.5595
Para Lv2
3.4636
Para Ld
3.1889
Para Fr
3.5800
Por lo tanto los muebles conectados a tuberias de AC cumplen con las presiones mnimas, por ende con la Norma.
3.1389

Instalacin hidrulica Agua Caliente


Tramo Q mx. (Lps) Coef. Sim. Q mx. prob. (Lps) Dimetro (m) Longitud (m) Accesorios
A-B
1.05
0.4082
0.4286
0.0268
3 2TSL (3.4), Ve (0.2), E (0.3)
B - Cal
0.25
0.5774
0.1444
0.0206
0.95 2C90 (1.2)
Cal - C
0.21
0.5774
0.1213
0.0206
2.45 2C90(1.2), TSL (1.7), TSB (1.7)
C-D
0.14
0.7071
0.0990
0.0206
13.5 C90 (0.6), TSB (1.7)
D-E
0.11
1
0.1100
0.0144
0.5 TPD (0.3)
E - Re
0.08
1
0.0800
0.0144
1.5 2C90 (0.8), TSL (1.3), Ve (0.1)
E - Lv1
0.03
1
0.0300
0.0144
4.4 2C90 (0.8)

Long. Equiv. (m) Long. T (m) hf (mca)


3.9
6.9
1.2
2.15
4.6
7.05
2.3
15.8
0.3
0.8
2.2
3.7
0.8
5.2

0.1513
0.0199
0.0461
0.0689
0.0258
0.0631
0.0125

D - Lv2
C - Fr

0.03
0.07

Mueble Presin (mca)


Wc
3.5
Lv
3.5
Ld
3.5
Re
2.1
Fr
3.5

1
1

0.0300
0.0700

0.0144
0.0144

9.4 3C90 (1.2)


7.9 3C90 (1.2)

1.2
1.2

10.6
9.1

La norma establece una serie de presiones minimas para muebles hidrulicos, enunciadas a continuacin:
Utilizando la frmula CD = CDT - (H mueble + hf mueble)
Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249
Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756
Para Lv2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884
Para Fr: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639
Ya que los muebles conectados a tuberias de AC cumplen con las presiones mnimas, la instalacin hidrulica cumple con la Norma.

0.0254
0.1188