Вы находитесь на странице: 1из 6
TYPE "AY FRAME AND COVER TO BE CONCRETE COLLAR MARKEO EMHER “SEWER” OR “DRAIN® fe OETIL SEE DETAILS F1-001 AND F1-D04 FINISHED GRADE GRADE RING PRECAST CONCRETE SECTIONS TO CONFORM TO ASTH—478, CONCRETE OF 4,000 PSI AT 28 oays "tye! MASTIC GASKET, TYPICAL ALL MANHOLE. JOINTS FILL LIFTING HOLES WITH CONCRETE POLYPROPYLENE stes 12" 0c. fey : TYPICAL REINFORCEMENT, hd WELDED WIRE FABRIC 6x6x4WxaW [—- MULTIPLES OF [2 s.0R [ MANHOLE BARRELS BS SHELVE TO SE BRICKS LAID FLAT es AT A SLOPE OF 1" PER FOOT (4) 5° MIN (2) + fe) CONCRETE FILL INVERT TO. BE INVERTED ARCH WITH BRICKS LAID AS STRECHERS AND ON EDGE one} ere.2 10" oR LESS —#4 AT 18 EW MIODEPTH "SCREENED GRAVEL BEDDING 10° To 20° #4 AT 12 EW MIDDEPTH H= 20" TO 30’ —#5 AT 12 EW MIDDEPTH TN ADDITION "TO WELDED WIRE FABRIC £ i & 5 £ NOTES: i 5 1, S'-O"DIMETER FOR ALL MANHOLE DEPTHS GREATER THAN 20 FEET OR WHEN ORDERED BY THE ENGINEER 2.5" MIN. WALL THICKNESS AND 7 INCH MIN. BASE THICKNESS WITH 5'—0" DIAMETER MANHOLES 3.6 INCH LIP OPTIONAL UNLESS OTHERWISE NOTED. 4. CONCRETE INVERT AND SHELF MAY 8E SUBSTITUTED IN, STORM DRAIN MANHOLES AS DIRECTED BY THE ENGINEER DETAIL NO. B-02a DATE: TYPICAL PRECAST CONCRETE MANHOLE Seale: Not To Seale Boston Water and Sewer Commission June 30, 2012 A Ene To & wine { 7 tow t) NON-SHRINK GROUT. (TP) TD {) cm PROVIDE MECHANICAL SEAL (ock=soNt FLENIBLE ML ‘SLEEVE, PRESS WEDGE SEAL OF LURK SEAL GASKET) EXCEST g | OR Steet connectie Bt sebete tae ee i sponbve0 8 awe ERD a Buen —] owizovral BPE ; Fi Exceeos 28" 3 | 6° MIN. TYPICAL CAST IN “SHELF PLACE CONCRETE. USE & _ Fos i ~ } =} oe: sen SECTION A-A DATE: DETAIL NO. Boston Water and DROP MANHOLE Sewer Commission une 20,2012 | B02 Smee ee feat ae ANOLE VARS. SEE DETAL 5-03 For CONCRETE COLAR SHELEY WaNHOLE STERS (12) (LOek=JONT FLEMBLE SLERIE PRESS WEDGE SEAL OF RK SEAL GASKER, EXCEPT BY BWSC. (TY) AY 4 ( wer} 6° SCREENED GRAVEL BEDDING Boston Water and Sewer Commission PRECAST CONCRETE MANHOLE FOR DATE: DETAIL NO. USE AT PIPE JUNCTIONS une 30,2012 | B-026 Seale: Not To Seale PLATFORM 2°x3/16" AT 173/16" ALUMINUM SERRATED GRATING WITH BANDED EDGES, TYP. MANHOLE STEPS FROM 1-0" ABOVE GRATING EXP. BOLTS © MANHOLE 1/4" RETAINER BAR 4 STAINLESS STEEL FASTENERS 4 EACH SECTION MANHOLE STEPS AT 12’ 0.0. STARTING 4°-0' ABOVE GRATING DOWN TO MANHOLE SHELF 540" DIA. MANHOLE “ PLAN VIEW 6, PLATFORM . <1 1/2" Ola Vf ——————————. ypas/iet cur” 1/4" cea Ay 4 4 4 ee RETAINER BAR 1/2" SST EXP BOLT AT 1-6" : 1/4 x -1/e Ltat/2" x 11/2" /4" le < NOTE: a 4 LANDING PLATFORMS SHALL SE PROVIDED FOR . EACH 20 FEET OF MANHOLE HEIGHT. SECTION A.A Boston Water and LANDING PLATFORM DETAIL DATE | BETAML Wa. Sewer Commission 5-FT DIA. MANHOLE June 30,2012 | B-02d Same omer Seat eae NOTES: 1. ALL CAST IN PLA STRENGTH OF 300! SIZE AGGREGATE CONCRETE TO HAVE A MINIMUM 28 DAY LBS PER SQ. INCH, USING 3/4”MAXIMUM 2. REINFORCING STEEL BARS ARE DEFORMED BARS OF BILLET STEEL ASTM A615 GRADE 60 3. WELDED WIRE FABRIC CONFORMS TO ASTM A185 4. CAST IRON FRAME, TYPE "A" AND COVER TYPE "A" FOR DETAILS SEE DETAILS NOS. Fi—DO1, F1—DO04 AND Fi—DOS COVERS TO 8E MARKED EITHER "SEWER” OR "DRAIN". 5. DESIGN LIVE LOAD — HS 20 — 44 6. MINIMUM COVER FOR REINFORCING IN WALLS OR SLABS POURED AGAINST EARTH SHALL BE 3 INCHES. ALL OTHERS SHALL BE 2 INCHES UNLESS OTHERWISE. ED 7. USE 2’-0" LENGTHS OF PIPE STUBS AT ALL MANHOLES FOR VC OR AC PIPE, USE 4’-0” MAX. LENGTHS OF PIPE STUBS AT ALL MANHOLES FOR RC, DI OR PVC oo THESE MANHOLE DETAILS TO BE USED FOR BOTH SANITARY SEWER AND STORM DRAIN MANHOLES ALL MANHOLES SHALL BE CONSTRUCTED OF REINFO! CONCRETE SHOP DRAWINGS SUBMITTALS SHALL SHOW REINFORCING DETAILS “ALL 10. MWRA OIL AND GREASE SEPARATOR IS USED WITHIN BUILDINGS WHERE REQUIRED BY MWRA (MASSACHUSETTS WATER RESOURCES AUTHORITY) OR DEP (DEPARTMENT OF ENVIRONMENTAL PROTECTION) REGULATION. FOR DETAILS SEE DETAIL NO. B04. FOR BWSC APPROVED GRIT AND OIL SEPARATORS, SEE DETAIL NOS. B-17 AND 8 Boston Water and MANHOLE STRUCTURES: DATE: Sewer Commission GENERAL NOTES June 30, 2012 Seale: Not To Seale DETAIL NO. B-02e 1. PORTION EMBEDDED INCONCRETE COATED WITH HEAVY-BODIED. BITUMINOUS MATERIAL AS SPECIFIED APPROVED. 2, MANHOLES GREATER THAN 15 FEET DEEP. SHELL SE CONSTRUCTED. WITHOUT STEPS Saye" EXTRUDED ALUMINUM “ALCOAT 6061-78 NO.126958 OR APPROVED EQUAL OR STEEL REINFORCED. POLYPROPYLENE PLASTIC, oR ALUMINUM MANHOLE STEP s/is arte SECTION A-A Boston Water and Sewer Commission DATE: DETAIL No. ALUMINUM MANHOLE STEP une 30,2012 | B-02f Seale: Not To Seale

Вам также может понравиться