Вы находитесь на странице: 1из 8
4!) Exveritas BUMI ARMADA ATEX /DSEAR EXAMINATION FOR ENGINEERING STAFF NAME: COMPANY: DATE: ‘Client / Location: Electrical Engineering Staff_ [Wrexham _ [Project ie Muthice am uesTors Project Number Tart 1: Gas and Vapour Endronmen \oexveritas ‘Document Revision: 1 | Date: [September 2014 | Doc. Status: | Released 1: With regards to “Ex” equipment, the main documents referenced are the IEC 60079 series of standards. In Europe it isa legal requirement to use EN versions. What does EN mean? A English Norm B c English Number D 2: Inthe jurisdiction of which Directive? A 94/92/EC B c¢ ()2014/34/eu D European Notation European Norm European Union, Health and Safety in explosive atmospheres comes under the 2014/34/EC 99/92/EC ‘Q3: Which type of protection concept could ignite a flammable gas if worked on live? [increased safety [_ Jal of the above [a cert welders used a Flameproof B c Type’ protection > {Q4: Welding and burning can be done in zone 1 area provided. A the areasfree of flammable 8 gas and appropriate safety permits issued c there is no smell of gas D the plant is on a shut-down Q5: Which aspect of 2 flammable gas has to be taken into account when assessing the ‘' rating of the equipment to be used in its presence? A c ‘um rade Electrical Engineering AtexDsear Pape art 1 Rev 1 November Flashpoint 8 Upper explosive limit > Gas group Ignition temperature Page Lof® © Ewer Lud Wexveritas Glent/ocation: Hiecical Engineering Sa [Wrexham Project Tite: ‘Multichoice kam ~ 30 Questions Project Number: Part: Gas and Vapour Environments Document Revision i_[ Date: | September 2016 | Doe. Status: [Released Q6: Personnel working in an explosive atmospheres must be competent. Whom does this apply to? A Electrical and instrument Engineers only c Installers Designated personnel only Everybody Q7: Gases requiring the least amount of energy are typically allocated in which sub-group? A uB, c mic B D a ie QB: Which type of protection is associated with the use of energy limiting devices? A Exi Q9: Naked flames are a source of ignition. A Always c ‘Sometimes D Exe Exo Never [ony at nigh Q10: Which of the following is the correct format for ATEX equipment marking for a gas and vapour environment/combustible dust environment? A ‘Q11: ATEX Directive (2014/34/EU) adopts the use of cat nape DT1206 tegories for equipment. Where can EPL Gb Db equipment be used, unless the risk assessment states otherwise? A Zone 0, 20 and less onerous zones c Zone 2 and 22 ‘Bumi Armada Eletcal Engineering Atex_Dsear Paper Pat 1 Rev 1 Novernber Zone 1.and 21 only Zone 1, 21 and less onerous zones Poge 2of8 © EWertastid Glent / Location Glecrcal Engineering Staff [irexiam Projet Tie Muti choce fxam = 30 Questions 4 Project Number Part 4: Gas and Vapour Environments Alb exVeritas Document Revisions | 1 | Oate: | September 2014 [Dor Situ —[ Relessed (Q12: Equipment for use in a gas and vapour ENVIRONMENT come under what group? A Group | c Group ttt 13: Hazardous area equipment should come with instr of that equipment? A Always c Only for zone 0 equipment A Equipment c Environment Q15: Toi applies to a zone 1? A [CJ smai circles c [-] vertical tines > 9-17:2014 Inspection checklist for Ex d eq D ans: number of directives including ATEX 137 is? A To establish more effective B custom boundaries between £.U. countries c To allow each country tohave D ‘ unique health and safety culture: Group it ‘None of the above ructions for the correct use/installation When requested Never uipment covers the following. {J instalation Allof the above jentify the “zones” on drawings, special markings are used. Which of the following ‘Symbols as shown the drawing legend Cross slanting lines irectives are developed for use throughout the European Union. The objective of a ‘To improve trade by removing ~ technical barriers between E.U. countries ‘To enable each member state to ‘Bum Armada Elect Engnceing Atex_Osear Paper Port 1 Rev 1 November have a common health and safety culture across Europe Page dots © eWertas.ud Client / Location Electrical Engineering Staff [Wresham Projet ie: Milcfice from= 30 Cues Project Number are: Gas and Vapour Enronmeris Wesveritas Document Revision: 1 | Date: [September 2014 | Doc. Status: | Released Q17: In accordance with the ATEX directive for equipment, equipment is divided into groups and categories. In which location can Group | category M2 equipment be located? A Industries associated with = B both Surface and Mining Industries. Mines susceptible to Fire > Damp Industries associated with explosive atmosphere formed by Methane Gold and Silver mines only. ical equipment is to be installed in an explosive atmosphe - What standard should renced for the periodic inspection requirements? 1EC 60079-17 B 1EC 60079-14 [_] tec 6079-19 D HEC 60079-1 ‘Q19: Which of the following temperature classes are suitable for gases with ignition temperatures less than 200°C? A 11,12, 13 B 14,75 and 76 c¢ []tonly > None of the above Q20: How many ignition sources are recognised in EN1127-1? A a B 15 c B > 7 Q21: Which European standard identifies the type of persons who need to be competent to carry out installations? A EN 60079-14 EN 6079-17 IEC 60079-14 EN 60079-19 ‘Bum Armada Electrical Engineering tex Oseat Paper Part 1 Rev 1 November Page dots © bWertasttd ‘Glient /ecation: Tlecrical Engineering Stal [Wresham Project Te Mullican = 30 QUenTonE : Project Number art: Gas and Vapour Environments WresWeritas Document Revision: ‘1 | Date: | September 2014 | Doc. Status: | Released 22: Who can install equipment in an explosive atmosphere? A A c Technically competent persons B ‘An domestic approved electrician ‘Anybody > I the engineers says you can ‘explosive gas/alr mixture is UNLIKELY to occur in normal operation, what will the area classification typically be? zoneo 8 Zone 1 Zone2 Oo \Non-Hazardous Q24: Which area is most likely to be classified as zone 1? The space above the liquid B Around the flange joints of pipes level ina tank carry flammable substances [J around awelded stainless [7] Around a vent which releases in steel pipeline ‘normal operation. Q25: Which area is most likely to be classified as non-hazardous? A (Q26: The design and selection of electrical equipment sI a ‘Around the flange joints of pipes carrying dangerous substances ‘Around a normally vented vent The space above theliquid = B level in a tank around a welded stainless D steel pipeline hall be carried out by whom? Persons who have had training B Persons who have had training on on the protection concepts Persons who have had training D area classification (zones) [J allof the above ‘on installation practices ‘uml Armada Elec Engineering AtexOsear Pape art Rev November ragesof8 OBAVertas itd Glient / Location: Electrical Engineering Staff [Wrexham Projet ie il choie Ea = 30 Guetione Projet Number Part: Gas and Vapour Environments Wexveritas ‘Document Revision: 1 Date: [September 2014 Doc. Status: [Released Q27: How many “GAS” explosive atmosphere zones are there? A c 2 B > {TEX equipment is marked with the letter GD means Itcan only beused in agas B ‘atmosphere It can only be used in dust > 3 5 Itcan be used in both gas and dust atmospheres It can only be used in coal mines atmosphere susceptible to firedamp 229: Equipment is marked with the letter D i.e. 1D, 2D this meaMs wenn A Itcan only be used in dry B It can be used in deserts atmospheres c Itcan be used in combustible D It can be used in dust areas in coal dust environments mines 030: An EPD document should be produced and retained. What does EPD mean? A Explosion Protection Dossier B Equipment Protected Document c Explosion Protected Document D Explosion Protection Document Office use only Total Number | Number | Percentage | Pass/Fail Signature attempted | correct__| wrong ‘uri Armada Electrical Engineering Atex_Dsear Paper Part 1 Rev 1 November Page 6 of8 © BWertasted Giant wean learn engineering Sa [ietam Project Tie Mub-choice Bam ~ 30 Questions Project Number art: Gas and Vapour Environments ‘Document Revision 1_[ tate: [september 2014 | —boe. Sanus [_ Released ExVeritas Units 16 -18 Abenbury Way Wrexham Industrial Estate Wrexham U3 9uz Telephone:+44 (0)845 862 2447 Facsimile:+44 (0) 845 862 2426 he enver ‘mi Armada Electrical Engneering Atox_Dsear Pape Part 1 Rev November Page70f8 © Gxvertas ind

Вам также может понравиться