Вы находитесь на странице: 1из 15

Faculty of Civil Engineering and Planning

Civil Engineering Department


Petra Christian University
BEND-OneWa

GENERAL
LAYOUT & VIEW
TYPE OF SUPPORT
EFFECTIVE SPAN
MAXIMUM SPACE BETWEEN SLAB REINFORCEMENT
DESIGN OF ONE WAY SLAB REINFORCEMENT
TABLES & GRAPHICS

BEND-OneWa

GENERAL
Basically one way slab has the same behavior as
simple supported beam or continuous beam.

The value of moment (due to bending) could be found


through :
a. principles of mechanics,
b. computer calculation
c. tables such as Table 4.1 of CUR IV
BEND-OneWa

LAY OUT & VIEW OF ONE-WAY SLAB


1.

2.
A

A-A

A-A

Slab is supported by
brick wall

Cantilever Slab
fixed at the beam

BEND-OneWa

LAYOUT & VIEW OF TWO-WAY SLAB

B-B

A-A
BEND-OneWa

TYPE OF SUPPORT

CUR 1, p. 70-71

1. FREE SUPPORTED

Before Loading

Free rotate

After Loading

2. FIXED SUPPORTED
Before Loading

3. PARTIALLY FIXED SUPPORTED


Before Loading
BEND-OneWa

After Loading

Partially rotate
After Loading

EFFECTIVE SPAN OF SLAB

CUR 1, p. 73-74

IF : b 2 h

h
L
Leff = L + b

IF : b > 2 h

L
Leff = L + 100 mm

Read : SKSNI sec. 3.1.7


BEND-OneWa

MAXIMUM SPACE BETWEEN SLAB REINFORCEMENT


SKSNI T15-1991-03 sec 3.16.6(5)
Main Reinforcement

s 3h or 500 mm

BEND-OneWa

DESIGN OF ONE WAY SLAB REINFORCEMENT


The slab is considered per - 1.00 meter width.
TABLE 5.1 - CUR IV could be used; and considered
per 1.00 meter width of slab.
GRAPHIC 5.4 - CUR IV could be used.

SEE TABLE 2.2a - CUR IV (p.15)

SEE TABLE 5.1a - e - CUR IV (p.44-48)

GRAPHIC 5.4 - CUR IV (p.70-80)

BEND-OneWa

DESIGN OF ONE-WAY SLAB


0.003
d

H = 0

C
0.85 fc.a.b
b = 1m 0.85 fc.a.b

C
d - a

As
b 1000 mm

0.85 fc

= T
= As .
= As . fy
As . fy
a =
0.85 fc .103

fs

... (1)

M = 0 Mn = T (d - a)
= As . fy (d - a). .... (2)
As fy
(1)(2)
Mu = As . fy (d - 0.59 f )
BEND-OneWa
c

10

ARRANGEMENT OF REINFORCEMENT
in Positive Bending Moment Area

10 - 100
10 - 100
10 - 100

BEND-OneWa

Secondary reinforcement
Main reinforcement

10 - 250

10 - 250

10 - 250

11

ARRANGEMENT OF REINFORCEMENT
in Negative Bending Moment Area

10 - 250

10 - 100
10 - 100
10 - 100

BEND-OneWa

10 - 250

10 - 250

Secondary reinforcement
Main reinforcement

12

TABLE 2.2a
AREA OF REINFORCEMENT PER 1.00 METER WIDTH OF SLAB
Space
of bar
(mm)

50
75
100
125
150
175
200
225
250

565
377
283
226
188
162
141
126
113

1005
670
503
402
335
287
251
223
201

BEND-OneWa

Diameter (mm)
10
12
14
1571
1047
785
628
524
449
393
349
314

2262
1508
1131
905
754
646
565
503
452

3079
2053
1539
1232
1026
880
770
684
616

16

19

20

4022
2681
2011
1608
1340
1149
1005
894
804

5671
3780
2835
2268
1890
1620
1418
1260
1134

6284
4189
3142
2513
2094
1795
1571
1396
1257

13

TABLE 5.1.a - CUR IV


Mu/bd2

= 0,8

CONCRETE STRENGTH fc 15

fy = 240 MPa

au
100
0,0005
0,191
200
0,0011
0,190
300
0,0016
0,189
400
0,0021
0,188
500
0,0027
0,187
600
0,0032
0,186
700
0,0038
0,185
800
0,0043
0,184
900
0,0049
0,183
1000
0,0055
0,182
1100
0,0061
0,181
1200
0,0067
0,180
1300
0,0073
0,179
1400
0,0079
0,178
..
.
.
3000
0,0190
0,158
3100
0,0199
0,156
3200
0,0207
0,155
3300
0,0216
0,153
3400
0,0225
0,151
3500
0,0234
0,150
BEND-OneWa

fy = 400 MPa

au
0,0003
0,318
0,0006
0,317
0,0010
0,315
0,0013
0,314
0,0016
0,312
0,0019
0,310
0,0023
0,309
0,0026
0,307
0,0029
0,305
0,0033
0,303
0,0036
0,302
0,0040
0,300
0,0044
0,298
0,0047
0,296

0,01114
0,263
0,0119
0,260
0,0124
0,258

c/d

z/d

0,012
0,023
0,035
0,047
0,059
0,071
0,084
0,096
0,109
0,122
0,135
0,148
0,161
0,174

0,422
0,440
0,458
0,478
0,497
0,518

0,995
0,990
0,985
0,980
0,975
0,970
0,964
0,959
0,954
0,948
0,943
0,937
0,932
0,926
...
0,821
0,813
0,805
0,797
0,789
0,780

14

300
280
260
240
220
200
180
160
140
120
100

fc 15 MPa

fy = 240 MPa

0 ,5
0

= 0,0025

16
0
14
0

12
0
10
0

1000

,7 5
=0

40

BEND-OneWa

=2

Mu

60

80

= 1,
4/f

d (mm)

GRAPHIC 5.4.a - CUR IV

2000

3000

4000

5000

As (mm2)

End of presentation

15