Академический Документы
Профессиональный Документы
Культура Документы
Split System
Cooling Product &
Performance Data
XB 10
TTB012-024
1, 1 & 2 Tons
General
Features
Split System Cooling
Units . . . Designed With
Your Needs In Mind.
TTB Split systems represent a new
approach to designing products for
The Trane Company. The design teams
mission is . . . to bring a system to the
marketplace that will meet your job
requirements every time . . . And at a
competitive price.
Tranes experienced design team used
the newest computer technology and
an entirely new manufacturing process
to develop a new standard in split
systems. Couple the Trane reputation
for quality and reliability in split system
air conditioners with improvements in
efficiency, flexibility and installation
ease . . . and you have systems that
prove Its Hard to Stop a Trane.
Manufacturing Control
Tranes exclusive control over the design
and manufacturing of all major components is unique in the industry. This
approach assures us total control over
both the quality and reliability of these
components. It also allows us to custom
match components to deliver the best in
split system performance.
Designing the Details
Careful attention was given to designing
the details from control wiring to the
access panels. TTB units feature timesaving color coded wiring and removable
panels which allow complete access to
all major components and controls. All
outdoor units feature external high and
low pressure gauge port connections,
and service valves for easy diagnosing
and servicing of the unit are provided.
Standardized Cabinets
In addition all cabinets have been
standardized; so when you are servicing
an outdoor unit or an air handler all
components are in the same location
from unit to unit.
UL Listed and ARI Certified
Trane meets or exceeds all nationally
recognized agency safety and design
standards. Each unit is UL approved,
and labeled in accordance to UL
Standard 1995, including approval for
use in Canada. Each unit is rated in
accordance with ANSI ARI Standard
210/240 and 270.
22-1689-05-0603 (EN)
Contents
General Features
Optional Equipment
Low Outdoor Ambient Cooling
A.R.I. Standard Capacity Rating Conditions
Selection Procedure
Model Number Nomenclature
General Data
TTB012C100A
TTB018C100A
TTB024C100A
22-1689-05-0603 (EN)
5
5
5
6
6
7
7
9
11
13
14
TTB012C
TTB018C
TTB024C
14
15
17
Electrical Data
19
Dimensions
20
21
Features and
Benefits
Climatuff compressor
All Aluminum Spine Fin coil
HCFC-22 refrigerant
22-1689-05-0603 (EN)
Features and
Benefits
Optional Equipment
] indicates accessories included).
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [
Indoor Thermostats Electronic Setback ............................................................................................................ TAYSTAT300C [
Electronic, 1 Htg. (Gas)/1 Clg. (Non Prog.) .......................................................................... TAYSTAT370 [
Electronic, 1 Htg. (Elec.)/ 1 Clg. (Non Prog.)3 ..................................................................... TAYSTAT371[
Heating/Cooling Horizontal ................................................................................................. AY28X092 [
Cooling Only with Fan Switch .............................................................................................. BAYSTAT304 [
Heating/Cooling Vertical ................................................................................................. BAYSTAT305 [
Thermostat Locking Cover .................................................................................................... BAY28X190 [
Outdoor Thermostats 46F. to -10F. (Adjustable) (TTB018-024) .......................................................................... TAYSTAT250B [
Evaporator Defrost Control .......................................................................................................................................... AY28X079 [
Indoor Fan Delay Relay Kit ........................................................................................................................................ BAY24X045 [
Quick-Start Kit (TTB012-024C) .................................................................................................................................. BAY41X228 [
Isolators .................................................................................................................................................................... BAYISLT100 [
Outdoor Temperature Sensor .. (TAYSTAT300C) ................................................................................................. TAYSENS100A [
]
]
]
]
]
]
]
]
]
]
]
]
]
BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)
5/8" ODM (90 bend, one end), 5/8" & 1/4" tubing ................................................................................................ TAYREFLN1__* [ ]
3/4" ODM (90 bend, one end), 3/4" & 5/16" tubing .............................................................................................. TAYREFLN2__* [ ]
* Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number.
Example: TAYREFLN220
As
Manufactured
Evaporator
Defrost Control
55F
55F
40F
30F
22-1689-05-0603 (EN)
Selection
Procedure
10
11
PRODUCT TYPE
Split Cooling - TTA, TTB, TTN, TTR TTP,
TTX, TTY, TTZ
Split Heat Pump - TWA, TWN, TWP,
TWR, TWX, TWY, TWZ
Package Cooling TCC, TCH, TCD, TCX, TCM, TCP, TCY
Package Heat Pump - WCC, WCD, WCH,
WCZ, WCM, WCP, WCX, DCX, WCY
Air Handler - TWE, TWG, TVF
Gas/Electric - YCC, YCD, YCH, YCP, YCX,
YCY, YCZ
Coils - TXA, TXE, TXC, TXH, CCB, CUB
MINOR DESIGN
MODIFICATION
SECONDARY FUNCTIONS
Gas/Electric - Gas Heating
Furnaces - Cooling Airflow
Air Handlers - Flow Control
POWER SUPPLY AND FUEL
MAJOR DESIGN MODIFICATION
22-1689-05-0603 (EN)
General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
TTB012C100A
82
200/230/1/60
11
15
15
CLIMATUFF
1-1
200/230/1/60
8.0 - 45
NO
NO
YES
PROPELLER
13.7 - 1
DIRECT - 1
1600
1 - 1/8
1650
200/230/1/60
0.83
SPINE FIN
1 - 24
6.62
3/8
R-22
2/12-LB/OZ
YES
5/8
1/4
TTB012C100A
0.049
H X W X D
24.75 X 20 X 20
SEE OUTLINE DWG.
SPLIT SYSTEM
118
112
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
CCBA18A4AC
FIXED ORIFICE
CUBA18A4AC
FIXED ORIFICE
TXA018C4
FACT INS 49
TXA024C4
CHG TO 49
TXA025C4
CHG TO 49
TXC018C4
FACT INS 49
TXC024C4
CHG TO 49
15800
10000
450
1.73
9.15/10.00
15800
10000
450
1.73
9.15/10.00
14800
9700
525
1.61
9.20/10.00
14400
9000
450
1.55
9.30/10.00
14700
9500
450
1.56
9.40/10.05
14800
9700
525
1.61
9.20/10.00
14400
9000
450
1.55
9.30/10.00
TXC024D4
CHG TO 49
TXC025C4
CHG TO 49
TXC025D4
CHG TO 49
TXH025A4
CHG TO 49
14400
9000
450
1.55
9.30/10.00
14700
9500
450
1.56
9.40/10.05
14700
9500
450
1.56
9.40/10.05
16200
10200
450
1.74
9.30/10.00
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
See
2TFB4018A1
FACT INS 49
2TFB4024A1
CHG TO 49
TVF018A14
FACT INS 49
TVF025A14
CHG TO 49
TWE018C14
FACT INS 49
TWE024C14
CHG TO 49
TWG018A14
FACT INS 49
16800
10900
450
1.78
9.45/10.00
16700
10800
450
1.82
9.20/10.00
15100
10000
450
1.56
9.65/10.50
14900
9800
450
1.62
9.20/10.00
14600
9300
450
1.56
9.35/10.20
14400
9100
450
1.55
9.30/10.20
14500
9300
450
1.56
9.30/10.00
22-1689-05-0603 (EN)
General
Data
TTB012C100A
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
TWG025A14
CHG TO 49
14200
9100
450
1.49
9.55/10.00
22-1689-05-0603 (EN)
General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA.(IN) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
TTB018C100A
82
200/230/1/60
11
15
15
CLIMATUFF
1-1
200/230/1/60
8.0 - 45
NO
NO
YES
PROPELLER
13.7 - 1
DIRECT - 1
1600
1 - 1/8
1650
200/230/1/60
0.83
SPINE FIN
1 - 24
6.62
3/8
R-22
3/3-LB/OZ
YES
5/8
1/4
TTB018C100A
0.049
H X W X D
24.75 X 20 X 20
SEE OUTLINE DWG.
SPLIT SYSTEM
118
112
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
CCBA18A4AC
FIXED ORIFICE
CCBA24A4AC
FIXED ORIFICE
CUBA18A4AC
FIXED ORIFICE
CUBA24A4AC
FIXED ORIFICE
CUBB24A4AC
FIXED ORIFICE
TXA018C4
FACT INS 49
TXA024C4
CHG TO 49
16600
11100
600
1.80
9.20/10.00
16600
11400
620
1.79
9.25/10.10
16600
11100
600
1.80
9.20/10.00
16600
11400
620
1.79
9.25/10.10
16600
11400
620
1.79
9.25/10.10
17000
11400
600
1.82
9.35/10.00
16800
11600
630
1.81
9.30/10.05
TXA025C4
CHG TO 49
TXC018C4
FACT INS 49
TXC024C4
CHG TO 49
TXC024D4
CHG TO 49
TXC025C4
CHG TO 49
TXC025D4
CHG TO 49
TXH025A4
CHG TO 49
17100
12700
640
1.83
9.35/10.00
16600
11100
600
1.80
9.20/10.00
16800
11600
630
1.81
9.30/10.05
16800
11600
630
1.81
9.30/10.05
17100
12700
640
1.83
9.35/10.00
17100
12700
640
1.83
9.35/10.00
17200
11900
640
1.85
9.30/10.00
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
See
2TFB4018A1
FACT INS 49
2TFB4024A1
CHG TO 49
2TFB4030A1
CHG TO 49
TVF018A14
FACT INS 49
TVF024A14
CHG TO 49
TVF025A14
CHG TO 49
TWE018C14
FACT INS 49
17800
12500
600
1.84
9.70/10.00
17900
13000
670
1.89
9.45/10.00
17800
12800
665
1.95
9.15/10.00
17300
12700
600
1.78
9.70/10.40
17400
13300
650
1.86
9.35/10.15
17500
13400
655
1.83
9.55/10.40
17100
11600
600
1.77
9.65/10.00
22-1689-05-0603 (EN)
General
Data
TTB018C100A
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
See
TWE024C14
CHG TO 49
TWG018A14
FACT INS 49
TWG025A14
CHG TO 49
16800
11600
625
1.79
9.40/10.00
16500
11400
600
1.77
9.30/10.00
16600
12100
620
1.74
9.55/10.00
10
22-1689-05-0603 (EN)
General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA.(IN) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
TTB024C100A
80
208/230/1/60
15
25
20
CLIMATUFF
1-1
200/230/1/60
11.6 - 60
NO
NO
YES
PROPELLER
13.7 - 1
DIRECT - 1
1550
1 - 1/8
1650
200/230/1/60
0.83
SPINE FIN
1 - 24
6.62
3/8
R-22
3/10-LB/OZ
YES
3/4
5/16
TTB024C100A
0.057
H X W X D
24.75 X 20 X 20
SEE OUTLINE DWG.
SPLIT SYSTEM
130
125
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
See
CCBA24A4AC
FIXED ORIFICE
CCBA30A4AC
FIXED ORIFICE
CCBB30A4AC
FIXED ORIFICE
CUBA24A4AC
FIXED ORIFICE
CUBA30A4AC
FIXED ORIFICE
CUBB24A4AC
FIXED ORIFICE
CUBB30A4AC
FIXED ORIFICE
22000
14900
800
2.40
9.15/10.00
21200
14500
775
2.36
9.00/10.00
22000
16200
800
2.39
9.20/10.00
22000
14900
800
2.40
9.15/10.00
21200
14500
775
2.36
9.00/10.00
22000
14900
800
2.40
9.15/10.00
22000
16200
800
2.39
9.20/10.00
TXA024C4
FACT INS 57
TXA025C4
FACT INS 57
TXA030C4
CHG TO 57
TXA031C4
CHG TO 57
TXA035C4
CHG TO 57
TXA036C4
CHG TO 57
TXC024C4
FACT INS 57
22200
15000
800
2.44
9.10/10.00
21800
15500
800
2.37
9.20/10.00
22200
15400
825
2.40
9.25/10.00
22400
16400
835
2.41
9.30/10.00
22000
15100
825
2.37
9.30/10.00
22800
16800
850
2.43
9.40/10.00
21400
14500
800
2.34
9.15/10.00
TXC024D4
FACT INS 57
TXC025C4
FACT INS 57
TXC025D4
FACT INS 57
TXC030C4
CHG TO 57
TXC030D4
CHG TO 57
TXC031C4
CHG TO 57
TXC031D4
CHG TO 57
21400
14500
800
2.34
9.15/10.00
21800
15500
800
2.37
9.20/10.00
21800
15500
800
2.37
9.20/10.00
22200
15400
825
2.40
9.25/10.00
22200
15400
825
2.40
9.25/10.00
22400
16400
835
2.41
9.30/10.00
22400
16400
835
2.41
9.30/10.00
22-1689-05-0603 (EN)
11
General
Data
TTB024C100A
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
TXC035C4
CHG TO 57
TXC035D4
CHG TO 57
TXC036C4
CHG TO 57
TXC036D4
CHG TO 57
TXC037C4
CHG TO 57
TXH025A4
FACT INS 57
TXH033A4
FACT INS 57
22000
15100
825
2.37
9.30/10.00
22000
15100
825
2.37
9.30/10.00
22800
16800
850
2.43
9.40/10.00
22800
16800
850
2.43
9.40/10.00
22800
16800
850
2.43
9.40/10.00
21400
14500
800
2.33
9.20/10.00
22400
16400
840
2.38
9.40/10.00
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
2TFB4018A1
CHG TO 57
2TFB4024A1
FACT INS 57
2TFB4030A1
CHG TO 57
TVF018A14
CHG TO 57
TVF024A14
CHG TO 57
TVF025A14
CHG TO 57
TVF030A14
CHG TO 57
21800
14600
675
2.29
9.50/10.00
22200
15500
800
2.39
9.30/10.00
22200
15800
825
2.44
9.10/10.00
21600
15000
675
2.34
9.25/10.20
22200
16300
800
2.40
9.25/10.20
22400
16500
800
2.38
9.40/10.40
23000
17700
850
2.43
9.45/10.40
TVF036A14
CHG TO 57
TWE018C14
CHG TO 57
TWE024C14
CHG TO 57
TWE030C14
CHG TO 57
TWE036C14
CHG TO 57
TWG018A14
CHG TO 57
TWG025A14
CHG TO 57
23000
17600
860
2.50
9.20/10.10
20800
13600
675
2.26
9.20/10.00
21000
14300
775
2.30
9.15/10.00
21800
15700
810
2.38
9.15/10.05
22600
16300
835
2.44
9.25/10.15
20400
13600
675
2.24
9.10/10.00
21000
14700
785
2.23
9.40/10.00
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
See
TWG030A14
CHG TO 57
21800
15400
815
2.36
9.25/10.00
12
22-1689-05-0603 (EN)
Ratings with
Auxiliary Devices
COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT
When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay and/or TXV kit
may increase the system SEER. See charts below for ratings.
OUTDOOR
MODEL
INDOOR
MODEL
TTB012C100A
TTB012C100A *
TTB012C100A
TTB012C100A *
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB012C100A
TTB018C100A
TTB018C100A *
TTB018C100A
TTB018C100A *
TTB018C100A
TTB018C100A *
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
TTB018C100A
2TFB4018A1
2TFB4018A1
2TFB4024A1
2TFB4024A1
CCBA18A4AC
CUBA18A4AC
TXA018C4
TXA024C4
TXA025C4
TXC018C4
TXC024C4
TXC024D4
TXC025C4
TXC025D4
TXH025A4
2TFB4018A1
2TFB4018A1
2TFB4024A1
2TFB4024A1
2TFB4030A1
2TFB4030A1
CCBA18A4AC
CCBA24A4AC
CUBA18A4AC
CUBA24A4AC
CUBB24A4AC
TXA018C4
TXA024C4
TXA025C4
TXC018C4
TXC024C4
TXC024D4
TXC025C4
TXC025D4
TXH025A4
FAN
DELAY
KIT
TXV
KIT
CFM
SEER
COOLING
CAPACITY
FI
FI
FI
FI
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
FI
FI
FI
FI
FI
FI
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NB
NB
NB
NB
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NB
NB
NB
NB
NB
NB
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
450
450
450
450
450
450
535
450
450
535
450
450
450
450
450
600
600
650
650
650
650
600
620
600
620
620
600
630
640
600
630
630
640
640
640
10.50
10.50
10.25
10.25
10.15
10.15
10.25
10.25
10.35
10.25
10.25
10.25
10.35
10.35
10.30
10.75
10.75
10.50
10.50
10.25
10.25
10.20
10.40
10.20
10.40
10.40
10.30
10.30
10.35
10.30
10.30
10.30
10.35
10.35
10.30
16600
16600
16400
16400
15800
15800
14800
14400
14700
14800
14400
14400
14700
14700
16200
17500
17500
17600
17600
17500
17500
16600
16600
16600
16600
16600
17000
16800
17100
17000
16800
16800
17100
17100
17200
FI - FACTORY INSTALLED
22-1689-05-0603 (EN)
B - BLEED TXV
OUTDOOR
MODEL
INDOOR
MODEL
TTB024C100A
TTB024C100A *
TTB024C100A
TTB024C100A *
TTB024C100A
TTB024C100A *
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
TTB024C100A
2TFB4018A1
2TFB4018A1
2TFB4024A1
2TFB4024A1
2TFB4030A1
2TFB4030A1
CCBA24A4AC
CCBA30A4AC
CCBB30A4AC
CUBA24A4AC
CUBA30A4AC
CUBB24A4AC
CUBB30A4AC
TXA018C4
TXA024C4
TXA025C4
TXA030C4
TXA031C4
TXA035C4
TXA036C4
TXA037C4
TXC018C4
TXC024C4
TXC024D4
TXC025C4
TXC025D4
TXC030C4
TXC030D4
TXC031C4
TXC031D4
TXC035C4
TXC035D4
TXC036C4
TXC036D4
TXC037C4
TXH025A4
TXH033A4
NB - NON-BLEED TXV
13
FAN
DELAY
KIT
TXV
KIT
CFM
SEER
COOLING
CAPACITY
FI
FI
FI
FI
FI
FI
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NB
NB
NB
NB
NB
NB
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
675
675
800
800
815
815
800
775
800
800
775
800
800
675
800
800
825
835
825
850
850
675
800
800
800
800
825
825
835
835
825
825
850
850
850
800
840
10.50
10.50
10.25
10.25
10.00
10.00
10.10
10.10
10.20
10.10
10.10
10.10
10.20
10.05
10.10
10.25
10.30
10.30
10.30
10.40
10.40
10.05
10.10
10.10
10.25
10.25
10.30
10.30
10.30
10.30
10.30
10.30
10.40
10.40
10.40
10.20
10.40
21600
21600
22000
22000
21800
21800
22000
21200
22000
22000
21200
22000
22000
20400
22200
21800
22200
22400
22000
22800
22800
20400
22200
22200
21800
21800
22200
22200
22400
22400
22000
22000
22800
22800
22800
21400
22400
Performance Data
Cooling
TTB012C WITH TXC018C4 AT 550 CFM
O.D.
D.B.
85
95
105
115
I.D.
W.B.
59
63
67
71
TOT.
CAP.
13.1
14.3
15.5
16.7
59
63
67
71
12.8
13.8
14.9
16.0
9.9
8.2
6.4
4.6
11.1
9.5
7.7
5.8
12.4
10.8
9.0
7.1
13.0*
11.6
9.8
7.9
1.57
1.60
1.62
1.65
59
63
67
71
12.2
13.2
14.1
15.2
9.6
8.0
6.2
4.3
10.9
9.3
7.4
5.5
12.2
10.5
8.7
6.8
12.5*
11.4
9.5
7.6
1.70
1.72
1.74
1.76
59
63
67
71
11.6
12.5
13.4
14.3
9.4
7.7
5.9
4.0
10.6
9.0
7.2
5.3
11.7*
10.3
8.4
6.5
12.0*
11.1
9.2
7.4
1.82
1.84
1.86
1.88
TOTAL
KW
1.46
1.49
1.52
1.54
450
600
0.96
1.01
TTB012C
0.91
1.04
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
14
22-1689-05-0603 (EN)
Performance Data
Cooling
TTB018C WITH TXC018C4 AT 600 CFM
O.D.
D.B.
85
95
105
115
I.D.
W.B.
59
63
67
71
TOT.
CAP.
14.7
15.9
17.2
18.6
TOTAL
KW
1.62
1.65
1.68
1.72
59
63
67
71
14.1
15.3
16.6
17.9
11.2
9.4
7.4
5.3
12.6
10.8
8.8
6.7
14.0
12.2
10.2
8.1
14.5*
13.1
11.1
9.0
1.74
1.77
1.80
1.84
59
63
67
71
13.4
14.5
15.7
16.9
10.8
9.0
7.0
5.0
12.3
10.4
8.4
6.3
13.5*
11.8
9.8
7.8
13.9*
12.8
10.8
8.7
1.88
1.91
1.94
1.97
59
63
67
71
12.6
13.7
14.8
16.0
10.5
8.7
6.7
4.6
11.9
10.1
8.1
6.0
12.9*
11.5
9.5
7.4
13.2*
12.5
10.4
8.4
2.02
2.04
2.07
2.10
525
675
0.98
1.02
0.94
1.05
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
22-1689-05-0603 (EN)
TTB018C
15
Performance Data
Cooling
TTB018C
16
22-1689-05-0603 (EN)
Performance Data
Cooling
TTB024C WITH TXC024C4 AT 800 CFM
O.D.
D.B.
85
95
105
115
I.D.
W.B.
59
63
67
71
TOT.
CAP.
19.1
20.7
22.4
24.1
TOTAL
KW
2.09
2.14
2.20
2.26
59
63
67
71
18.3
19.8
21.4
23.1
14.6
12.2
9.5
6.8
16.5
14.1
11.4
8.7
18.3*
15.9
13.2
10.5
18.8*
17.2
14.5
11.8
2.22
2.28
2.34
2.40
59
63
67
71
17.2
18.6
20.1
21.7
14.1
11.7
9.1
6.3
16.0
13.6
10.9
8.2
17.5*
15.5
12.8
10.0
17.9*
16.7
14.0
11.3
2.36
2.42
2.49
2.55
59
63
67
71
16.1
17.5
18.9
20.3
13.7
11.3
8.6
5.9
15.6
13.2
10.4
7.7
16.6*
15.0
12.3
9.6
17.0*
16.2
13.6
10.8
2.51
2.57
2.63
2.70
700
900
0.98
1.01
0.94
1.05
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
22-1689-05-0603 (EN)
TTB024C
17
Performance Data
Cooling
TTB024C
18
22-1689-05-0603 (EN)
Electrical
Data
SCHEMATIC DIAGRAMS
TTB012-024C
LEGEND
SYMBOL
19
Dimensions
MODEL
TTB012C
5/8
1/4
TTB018C
5/8
1/4
TTB024C
3/4
5/16
22-1689-05-0603 (EN)
Mechanical
Specification Options
General
This unit is fully charged from the factory
for up to 15 feet of piping. This unit is
designed to operate at outdoor ambient
temperatures as high as 115F. Cooling
capacities matched with a wide selection
of air handlers and furnace coils that are
A.R.I. certified. The unit is UL listed for
outdoor application.
Casing
Unit casing is constructed of heavy
gauge, galvanized steel and painted with
a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include
condenser fan and compressor
contactor. High and low pressure controls
are inherent to the compressor. A factory
installed liquid line drier is standard.
Compressor
The Climatuff compressor features a
5-year limited warranty, internal over
temperature and pressure protection,
total dipped hermetic motor windings.
Other features include: roto lock suction
and discharge refrigerant connections,
centrifugal oil pump and low vibration
and noise.
22-1689-05-0603 (EN)
21
Condenser Coil
The Spine Fin coil is continuously
wrapped, corrosion resistant aluminum
with minimum brazed joints. This coil is
3/8 inch O.D. seamless aluminum glued
to a continuous aluminum fin. The coil is
protected on all four sides by louvered
panels and has a 5-year limited warranty.
Low Ambient Cooling
As shipped, this unit has a cooling
capability to 55F. The addition of an
evaporator defrost control permits
operation to 40F. The addition of an
evaporator defrost control with TXV
permits low ambient cooling to 30F.
Accessories
Thermostats Cooling only and heat/
cooling (manual and automatic
changeover). Sub-base to match thermostat and locking thermostat cover.
Quick Start Kit Required for system
with reciprocating compressors when
applied with indoor coils with non-bleed
expansion devices. Low voltage operation: to 180 V. for systems with reciprocating compressors; to 187 V. for
systems with scroll compressors.
Evaporator Defrost Control See Low
Ambient Cooling.
Notes
22
22-1689-05-0603 (EN)
Notes
22-1689-05-0603 (EN)
23
Trane
A business of
American Standard Companies
www.trane.com
Literature Order
Order Number
Number
SS-PRC007-EN
SS-PRC018-EN
File Number
Number
PL-UN-SS-PRC018-EN
06/03
Supersedes
SS-PRC007-EN
TTB-D-7
12/00 2/02
Stocking Location
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.
P.I.