PRTICA NECTAS 1641-1651

ACESSAR O NECTAS
USURIO ADMIN
SENHA ADMIN
BELL > DISABLE
BACKUP
1641 SM SALVAR:
EQUIPAMENT CONFIGURATION
CONNECTION CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
1651 SM SALVAR:
EQUIPAMENT CONFIGURATION
CONNECTION CONFIGURATION WITH FULL MATRIX
CONNECTION CONFIGURATION WITH VC4 MATRIX
DROP SHELF CONNECTION CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
(SE HOUVER DVIDA SALVAR TUDO)
OBS: ONDE TIVER DROP SHELF NO PRECISA SALVAR (1641 SMD), NO 1651 VAI
ESTAR A MATRIX FULL OU A VC4.
DROP SHELF UM SUB BASTIDOR DO 1641 ASSOCIADO AO 1651. O 1651
EQUIPADO AT 1 STM1, COM O DROP SHELF ESSA CAPACIDADE AMPLIADA
COM 3 STM1, FICANDO AT 4 STM1.
EXECUTANDO BACKUP
ABRIR ELEMENTO DE REDE (DUPLO CLICK)
EQUIPAMENT CONFIGURATION >
FILE > RECIVE
DIGITAR DADOS DA ESTAO > OK
CONNECTION CONFIGURATION
FILE > RECIVE
DIGITAR DADOS DA ESTAO > OK
LOCAL CONFIGURATION
FILE > RECIVE
DIGITAR DADOS DA ESTAO > OK
ROUTING TABLES
FILE > RECIVE

DIGITAR DADOS DA ESTAO > OK


PARA SALVAR EM OUTRA PASTA
IR AT A PASTA C: ALCATEL /1641 SM 27 OU 1651 SM 25 (COPIA PARA A PSTA DA
ESTAO SEM AUTERAR O ARQUIVO)
TROCAR SMEC
1
ON
OFF
OFF

2
OFF
ON
OFF

ON
ON

ON
OFF

DIP SWITCH
POSIO NORMAL
POSIO LIMPEZA DE BANCO DE DADOS
RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS,
LAPD, ETHERNET).
RETAURAR O BANCO DE DADOS
POSIO NORMAL

PASSOS:
PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON INSERIR A PLACA E
AGUARDA O LED ABN ACENDER. (O BANCO FOI LIMPO).
PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON INSERIR A PLACA, AGUARDA
O LED ABN ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION).
PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON INSERIR A PLACA, AGUARDA O
LED ABN ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE).
PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF INSERIR A PLACA, AGUARDA
O LED ABN ACENDER.
PARA RESTORE
FILE SEND (SELECIONA ARQUIVO DA ESTAO E CLICA OK)
SEQUENCIA DE TABELAS:
CONNECTION CONFIGURATION
EQUIPMENT CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
DEMAIS TABELAS
INSERIR NA GERNCIA
LAPD
ETHERNET CONFIG (S para cnes)

1- LAPD
ABRIR ELEMENTO DE REDE (DUPLO CLICK)
CLICA EM LAPD CONFIGURATION >AGRR STMI E1 (USER)
>AGRR STM1W1 (NETWORK)
LOCAL CONFIGURATION > YES
> NETWORK
TABLES > MS LAPD CONFIGURATION
E1 > W1
2 ETH > YES
> FALSE (L2 ONLY)
3 OS ADRESS
INSERIR NSAP DA GERNCIA
NO
NO
4 NE ADRESS (LOCAL CONFIGURATION)
INSERIR NSAP E 7.1 (ADRESS DO NE)
SISTEM ID (EX 002060222222)
7.1 = 8
FILE > SAVE > FILE > SEND.
OBS-SE HOUVER MUDANA DO NSAP, O SISTEMA EXECUTA REBOOT.
NECESSRIO CONECTAR NOVAMENTE.

ACESSO REMOTO
1 DECLARAR NO MEU ELEMENTO DE REDE, OS NSAPS QUE QUERO VER
REMOTAMENTE.
LOCAL / CONFIG > R-ECT
YES (MARCA)
DIGITA NSAP E 7.1 ADRESS DOS NES REMOTOS.
CLICA EM NEXT PARA CRIAR OUTRO NE.
FILE > SAVE > FILE > SEND.
FECHAR O NECTAS
2 MENU INICIAR
>PROGRAMAS > ALCATEL > NETWORK CONFIG
>NETWORK CONFIGURATION
>NETWORK > CREATE > DEFAUT
> NETWORK NAME (GENERAL)
> CREATE
3 ABRIR PAINT BRUSH PARA CRIAR UM FUNDO, QUE SER INSERIDO NA
REDE (GENERAL).

FAA UM COPY NO PAINT BRUSH E UM MAP > PASTE NO MAPA GENERAL.


4 CRIAR UM NE GENRICO QUALQUER
EQUIPAMENT > CREATE > ME (0) > SECONDARY ADRESS (5) > CREATE
BOTO ESQUERDO > LOCATE EQUIPAMENT > LOCALIZE
5 EDITAR WIN INI
IR A C: / WINT / WIN.INI E EDITAR COM OS DADOS:
[ PEX ]
COMPEX=COM1:
PEXLOAD=
12TimRetrasmiis=20sec
12TimPolling=4sec
12TimResponse=5sec
12Retry=1
NETCFG_RECT=YES
NETCFG_NETWORK=C:/NETWORK/REDE/
TXTPATH=C:NETWORK/REDE/TXTFILE/
NETWORK_RF=REDE
NETPATH=C:/NETWORK/REDE/NETFILE/
WMFPATH=C:/NETWORK/REDE/WMFILE/
NETWORK=REDE
OBS-CASO O NOME DO MAPA SEJA GENERAL, SUBSTITUIR A PALAVRA REDE
POR GENERAL.
6 ABRIR O NECTAS
VIW > NETWORK (Aparecer todos os elementos criados)
OBS-de 2 a 5 a configurao do Laptop
VIW > SUB NETWORK / EQUIPAMENTS ( duplo click)
ALARMS E STATUS > OK
CROSS CONEXO
CRIANDO CIRCUITO DE 2 MB
ABRE O NE (duplo click)
CONNECTION CONFIGURATION > OK
FILE > RECIVE > SELECIONA ESTAO > OK (Salva)
TABLE > PAYLOAD STRUTURE AND SIGNAL LABEL > OK
TABLE > TU-12S ALLOCATION FOR 21X2M/SCDMA TRIBUTARY > OK
EQUIPA O TRIBUTRIO
EQUIPA O TU12 (CRIAR CORRESPONDENCIA COM O LADO REMOTO)
EQUIPA O MODE (D / I BIDI UNP E OU W (E OU W DE ACORDO COM O PROJETO,
UM LADO E O OUTRO W)).

FILE > SEND > SAVE > SEND


OBS= NO LADO REMOTO DEVE SE FAZER O MESMO PROCESSO
1641, 1651, 1664 S DOIS AGREGADOS.
FAZER LOOP 2MB
ABRE O NE (duplo click)
CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK
CLICA LOGIC > T2M 1 (PLACA DE TRIBUTRIO PRINCIPAL)
CLICA NO TRIBUTRIO
CLICA REMOTE_CONTROL
CURRENT DISPLAY
ENABLE INT LOOP 2M (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO
ENABLE LINE LOOP 2M (PARA FORA DO EQUIPAMENTO) INSTRUMENTO
FAZER LOOP DE AGREGADO
ABRE O NE (duplo click)
CLICA ALARMES, STATUS AND REMOTE CONTROLS > OK
CLICA LOGIC > AG-1 E1 (IN) PLACA DE AGREGADO PRINCIPAL
CLICA REMOTE_CONTROL
CURRENT DISPLAY
ENABLE INT LOOP (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTO
ENABLE LINE LOOP (PARA FORA DO EQUIPAMENTO) INSTRUMENTO

FORAR LASER
ABRE O NE (duplo click)
CLICA FILE > RECIVE > SAVE > TABLE > OPTICAL SAFETY CONFIGURATION
SELECIONA A OPO DESEJADA:
ALS DISABLE SET TX ON (LASER FORADO)
ALS DISABLE SET TX OFF (LASER DESLIGADO)
ALS DISABLE (CONDIO NORMAL DE LASER)
FILE SEND > OK (CONFERIR A ESTAO)
OBS: PARA DESFAZER REPETE O PROCESSO.

FORAR COMUTAO

ABRE O NE (duplo click)


CLICA FILE > RECIVE > SAVE >
ALARMS, STATUS AND REMOTE CONTROLS >
> CLICA LOGIC > CLICA NA PLACA CORRESPONDENTE ( EX AGGR MAIN)
> REMOTE CONTROL > CURRENT DISPLAY >
> MANUAL ACTIVE STM1 AGGR
OBS: PARA RETIRAR A COMUTAO FORADA
> SELECIONA A PLACA > REMOTE CONTROL > CURRENT DISPLAY >
> CLEAR FORCE ACTIVE STM1 AGG
* COMUTAO MANUAL: VERIFICA O OUTRO RECURSO ANTES DE COMUTAR
* COMUTAO FORADA NO VERIFICA O OUTRO RECURSO ANTES DE
COMUTAR.
SINCRONISMO
CRU MAIN
ABRE O NE (duplo click)
FILE > RECIVE > SAVE >
EQUIPMENT CONFIGURATION > OK
FILE > RECIVE AGUARDA
NOMEIA A ESTAO > OK
TABLE > SYNCRHRONIZATION: ADM TYPE & TRIBUTARY
CONFIGURATION > OK
MARCA SINGLE ADM
SE QUIZER 2M SELECIONA TRIB 1,2,OU 3 E A PORTA = 1 PORTA
CLICA EM OK
TABLE > SYNCRHRONIZATION PRIORITY LIST CONFIGURATION > OK
Fazer sair por T4 o sinal que tiver entrando na entrada de sincronismo externo T3.
Normalmente T4=T0.
Referncia 1- 2 MHz = GPS (melhor relgio, qualidade G811)
Priority de 1 a 6 (1 mais prioritrio)
Squelch , bloqueia o sinal de relgio se no for melhor ou igual a referncia indicada.
OBS: O sistema procura trabalhar com a melhor qualidade, depois avalia a prioridade.
Sequencia de qualidade: G811, G812t, G812l, G813.
SSM ALGORITHM ENABLE = MARCAR
( QUEM DEFINE PARA OLHAR PRIMEIRO A QUALIDADE) > CLICA EM OK
TABLE > SYNCRHRONIZATION: SSM VALUE CONFIGURATION

INFORMA A QUALIDADE: EXTRATED PARA RX ( E1 OU W1)


INSERTED PARA TX (E1 OU W1)
CLICA EM OK
SOFTWARE MISMASH
CRU MAIN ALARMANDO (PODE SE COMUTAR A SMEC)
VERSO DE UNIDADES
ABRE O NE (duplo click)
CLICA FILE > RECIVE > SAVE >
ALARMS, STATUS AND REMOTE CONTROLS >
SW VERSION > CLICA NA PLACA
PARA VER PACOTE DE SOFTWARE
ABRE O NE
> SOFTWARE DOWNLOAD > (VERIFICAR VERSES, PACOTE SMEC,
DOWNLOADS)
> NE IDENTIFICATION > (MOSTRA 2 PACOTES DE SOFTWARES DENTRO DA
SMEC EX 1641 V2.7.37)
> DESCRIPTOR FILE > (VERIFICA AS VERSES DAS UNIDADES EX CRU 3.5.11)
PARA COMUTAR BANCO DE DADOS
SOFTWARE MANAGMENT > ACTIVE > OK (IR COMUTAR O BANCO DE
DADOS)
OBS: SE O BOTO ACTIVATE NO ESTIVER HABILITADO, DEVE SE FSZER O
DOWNLOAD NOVAMENTE.
DOWNLOAD
SW DOWNLOAD MENU
SW DOWNLOADING (CLICA EM NE TYPE E APAGA 27)
SELECIONA O PACOTE (1641 V2.7.37)
CLICA CODE PRESENTE.
OBS: FORCED DOWNLOAD S NECESSRIO SE NO FUNCIONAR. O CODE
PRESENTE SIGNIFICA QUE O SOFTWARE IR AUTERAR SOMENTE OS DADOS
QUE FOREM DIFERENTES.
CONFIGURAR PROTEO
EQUIPAMENT CONFIGURATION
TABLE > EPS-ARS
MARCA A PLACA E SELECIONA EPS > CLICA OK > FILE > SEND

PRACTICE NECTAS 1641-1651


ACCESS NECTAS
USER - ADMIN
PASSWORD - ADMIN
BELL> DISABLE
BACKUP
1641 - SM SAVE:
EQUIPMENT CONFIGURATION
CONNECTION CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
1651 - SM SAVE:
EQUIPMENT CONFIGURATION
CONFIGURATION CONNECTION WITH FULL MATRIX
CONFIGURATION CONNECTION WITH MATRIX VC4
DROP SHELF CONFIGURATION CONNECTION
LOCAL CONFIGURATION
ROUTING TABLES
(IF ANY DOUBT SAVE ALL)
NOTE: WHERE HAVE NOT DROP SHELF NEEDS SAVE (1641 SMD), IN 1651
WILL BE A FULL MATRIX OR VC4.
DROP SHELF IS A SUB FRAME OF 1641 TO 1651 The 1651 ASSOCIATE IS
EQUIPPED TO 1 STM1, WITH DROP SHELF this capability is COM 3 STM1,
GETTING UP TO 4 STM1.
BACKUP RUNNING
OPEN NETWORK ELEMENT (DOUBLE CLICK)
EQUIPMENT CONFIGURATION>
FILE> RECEIVE
ENTERING DATA STATION> OK
CONNECTION CONFIGURATION
FILE> RECEIVE
ENTERING DATA STATION> OK
LOCAL CONFIGURATION
FILE> RECEIVE
ENTERING DATA STATION> OK
ROUTING TABLES
FILE> RECEIVE

ENTERING DATA STATION> OK


TO SAVE IN ANOTHER FOLDER
GO TO THE FOLDER C: ALCATEL / 1641 OR 1651 SM 27 SM 25 (COPY TO PUT
THE SEASON WITHOUT AUTERAR FILE)
CHANGE SMEC
1
ON
OFF
OFF

2
OFF
ON
OFF

ON
ON

ON
OFF

DIP SWITCH
NORMAL POSITION
CLEANING POSITION ON DATABASE
RESTORE LOCAL CONFIGURATION (NE, THE ADDRESS,
LAPD, ETHERNET).
RESTORE DATABASE
NORMAL POSITION

STEPS:
STEP 1 - REMOVE SMEC DIP DIP 1 OFF 2 ON - INSERT PLATE LOOKS AND
LED LIGHTING ABN. (THE BANK WAS CLEAN).
STEP 2 - REMOVE SMEC I DIP DIP 2 OFF ON -. INSERT PLATE, LOOKS ABN
LED LIGHTING (WAS RECOVERED LOCAL CONFIGURATION).
STEP 3 REMOVE SMEC I DIP DIP 2 ON ON - INSERT PLATE, LOOKS ABN LED
LIGHTING (SEND BACKUP TABLES TO NE)..
STEP 4 - REMOVE SMEC DIP DIP 2 OFF ON I - INSERT PLATE, LOOKS ABN
LED LIGHTING.
TO RESTORE
SEND FILE (FILE SELECT STATION AND CLICK OK)
SEQUENCE OF TABLES:
CONNECTION CONFIGURATION
EQUIPMENT CONFIGURATION
LOCAL CONFIGURATION
ROUTING TABLES
OTHER TABLES
INSERT IN MANAGEMENT

LAPD
ETHERNET SETUP (Only for cne's)
LAPD 1
OPEN NETWORK ELEMENT (DOUBLE CLICK)
CLICK ON LAPD CONFIGURATION> AGRR STMI E1 (USER)
> AGRR STM1W1 (NETWORK)
LOCAL CONFIGURATION> YES
> NETWORK
TABLES> MS LAPD CONFIGURATION
E1> W1
2 - ETH> YES
> FALSE (L2 ONLY)
3 - THE ADDRESS
INSERT NSAP MANAGEMENT
NO NO
4 - NE ADDRESS (LOCAL CONFIGURATION)
INSERT NSAP E 7.1 (ADDRESS OF NE)
SYSTEM ID (EX 002 060 222 222)
8 = 7.1
FILE> SAVE> FILE> SEND.
NOTE-IF ANY CHANGE NSAP, PERFORMING SYSTEM REBOOT. YOU MUST
CONNECT AGAIN.

REMOTE ACCESS
1 - DECLARE IN MY ELEMENT NETWORK, YOU WANT TO SEE THE NSAP'S
REMOTELY.
LOCATION / CONFIG> R-ECT
YES (BRAND)
NSAP 7.1 DIGITAL AND ADDRESS OF REMOTE NE'S.
CLICK ON NEXT TO CREATE ANOTHER NE.
FILE> SAVE> FILE> SEND.
CLOSE THE NECTAS
2 - START MENU
> PROGRAMS> ALCATEL> NETWORK SETUP
> NETWORK CONFIGURATION
> NETWORK> CREATE> DEFAUT
> NETWORK NAME (GENERAL)
> CREATE

3 - OPEN PAINT BRUSH TO CREATE A FUND TO BE ENTERED IN THE NET


(GENERAL).
MAKE A "COPY" IN PAINT BRUSH AND A "MAP> PASTE" IN GENERAL MAP.
4 - CREATE A GENERIC ANY NE
EQUIPMENT> CREATE> ME (0)> SECONDARY ADDRESS (5)> CREATE
LEFT BUTTON> LOCATE EQUIPMENT> FIND
5 - EDIT WIN INI
The IR C: / WINT / WIN.INI AND EDITING WITH DATA:
[PEX]
COMPEX = COM1:
PEXLOAD =
12TimRetrasmiis = 20sec
12TimPolling = 4sec
12TimResponse = 5sec
12Retry = 1
NETCFG_RECT = YES
NETCFG_NETWORK = C: / NETWORK / NETWORK /
TXTPATH = C: NETWORK / NETWORK / txtfile /
NETWORK_RF = NETWORK
NetPath = C: / NETWORK / NETWORK / NETFILE /
WMFPATH = C: / NETWORK / NETWORK / WMFILE /
NETWORK = NET
NOTE-IF THE NAME IS GENERAL MAP, REPLACE THE WORD NETWORK IN
GENERAL.
6 - OPENING NECTAS
VIW> NETWORK (appears all elements created)
OBS-2-5 is the configuration of Laptop
VIW> SUB NETWORK / Equipaments (double click)
ALARMS AND STATUS> OK
CROSS CONNECTION
CREATING CIRCUIT 2 MB
OPENS THE NE (double click)
CONNECTION CONFIGURATION> OK
FILE> RECEIVE> SELECT STATION> OK (Save)
TABLE> struture PAYLOAD AND SIGNAL LABEL> OK
TABLE> TU-12'S ALLOCATION FOR 21X2M / SCDMA TRIBUTARY> OK
MANS TAX
MANS TU12 (CREATE CORRESPONDENCE WITH REMOTE SIDE)

The TEAM MODE (D / I BIDI UNP AND OR W (E W OR UNDER THE PROJECT,


ONE SIDE AND THE OTHER W)).
FILE> SEND> SAVE> SEND
OBS = IN SIDE REMOTE SHOULD DO THE SAME PROCESS
1641, 1651, 1664 ONLY TWO HOUSEHOLDS.
DO LOOP 2MB
OPENS THE NE (double click)
CLICK ALARM, STATUS AND REMOTE CONTROLS> OK
CLICK LOGIC> T2M 1 (MAIN BOARD OF TAX)
CLICK ON TAX
CLICK REMOTE_CONTROL
CURRENT DISPLAY
INT ENABLE LOOP 2M (INTO THE EQUIPMENT) REMOTE LOOP
ENABLE LINE LOOP 2M (OUT OF EQUIPMENT) - INSTRUMENT
DO LOOP OF HOUSEHOLD
OPENS THE NE (double click)
CLICK ALARM, STATUS AND REMOTE CONTROLS> OK
CLICK LOGIC> AG-1 E1 (IN) BOARD OF HOUSEHOLD HOME
CLICK REMOTE_CONTROL
CURRENT DISPLAY
INT ENABLE LOOP (INTO THE EQUIPMENT) REMOTE LOOP
LINE LOOP ENABLE (OUT OF EQUIPMENT) - INSTRUMENT

FORCE LASER
OPENS THE NE (double click)
CLICK FILE> RECEIVE> SAVE> TABLE> OPTICAL CONFIGURATION SAFETY
Select a desired option:
ALS TX DISABLE SET ON (FORCED LASER)
ALS TX DISABLE SET OFF (OFF LASER)
DISABLE ALS (NORMAL CONDITION OF LASER)
SEND FILE> OK (ENSURING THE SEASON)
NOTE: FOR SCRAP REPEAT THE PROCESS.

FORCE SWITCH
OPENS THE NE (double click)
CLICK FILE> RECEIVE> SAVE>
ALARMS, STATUS AND REMOTE CONTROLS>
> CLICK LOGIC> CLICK ON BOARD CORRESPONDENT (EX AGGR MAIN)
> REMOTE CONTROL> DISPLAY CURRENT>
> MANUAL ACTIVE STM1 AGGR
NOTE: FORCED TO REMOVE THE SWITCH
> SELECT BOARD> REMOTE CONTROL> DISPLAY CURRENT>
> CLEAR ACTIVE FORCE STM1 AGG
* MANUAL SWITCH: VERIFY OTHER REMEDY BEFORE SWITCHING
* SWITCHING FORCED NOT VERIFY THE OTHER REMEDIES BEFORE
SWITCHING.
TIMING
RAW MAIN
OPENS THE NE (double click)
FILE> RECEIVE> SAVE>
EQUIPMENT CONFIGURATION> OK
FILE> RECEIVE LOOKS ...
STATION NAMES> OK
TABLE> SYNCRHRONIZATION: ADM TRIBUTARY TYPE & CONFIGURATION>
OK
SINGLE BRAND ADM
If I want 2M SELECTS TRIB 1.2, AND THE DOOR OR 3 = 1 DOOR
CLICK ON OK
TABLE> SYNCRHRONIZATION PRIORITY LIST CONFIGURATION> OK
Making out on the T4 signal you entering the external sync input T3.
Normally T4 = T0.
Reference 1 = 2 MHz (GPS clock best quality G811)
Priority 1-6 (highest priority first)
Squelch blocks the clock signal if not better than or equal to reference indicated.
NOTE: The system seeks to work with the best quality, then evaluates the priority.
Sequence quality: G811, G812t, G812l, G813.
ALGORITHM SSM MARK ENABLE =

(It DEFINE WHO LOOK FOR FIRST QUALITY)> CLICK ON OK


TABLE> SYNCRHRONIZATION: SSM VALUE CONFIGURATION
INFORMATION QUALITY: EXTRATED FOR RX (OR E1 W1)
INSERTED TO TX (OR E1 W1)
CLICK ON OK
SOFTWARE mismash
RAW MAIN alarming (CAN SWITCH The SMEC)
VERSION OF UNITS
OPENS THE NE (double click)
CLICK FILE> RECEIVE> SAVE>
ALARMS, STATUS AND REMOTE CONTROLS>
SW VERSION> CLICK ON BOARD
TO SEE SOFTWARE PACKAGE
OPENS THE NE
> DOWNLOAD SOFTWARE> (CHECK VERSIONS, PACKAGE SMEC,
DOWNLOADS)
> NE IDENTIFICATION> (2 SHOW PACKAGES SOFTWARE WITHIN THE EX
1641 V2.7.37 SMEC)
> DESCRIPTOR FILE> (VERIFY THE VERSIONS OF UNITS EX RAW 3.5.11)
SWITCH TO DATABASE
SOFTWARE MANAGMENT> ACTIVE> OK (WILL SWITCH DATABASE)
NOTE: IF YOU DO NOT ACTIVATE BUTTON ENABLED, SHOULD FSZER
DOWNLOAD AGAIN.
DOWNLOAD
SW DOWNLOAD MENU
DOWNLOADING SW (NE TYPE AND CLICK ON DELETE 27)
SELECT PACKAGE (1641 V2.7.37)
CLICK THIS CODE.
NOTE: FORCED DOWNLOAD IS ONLY NECESSARY IF IT DOES NOT WORK.
The CODE THIS MEANS THAT THE SOFTWARE WILL ONLY AUTERAR DATA
THAT ARE DIFFERENT.
SET PROTECTION
EQUIPMENT CONFIGURATION

TABLE> EPS-ARS
MARK AND BOARD SELECTS EPS> CLICK OK> FILE> SEND