Loads Computations:
Cee Purlin C3 x 4.1
Weight of Cee Purlin
= 6.14 kg /m
= 16 pcs
Spacing of Truss
=3m
# of Joints to be divided in WT
= 11 pcs.
Roofing
= Corrugated Galvanized
Unit Weight:
PD = 0.1602 kPa
PL = 0.60 kPa
Truss Length, L
= 15m
= 7.91 m
Tributary Area, AT
= 1.5m x 7.91m
= 11.865 m2
DEAD LOADS
Truss Weight, 0.4 +0.04L , L-feet
WTRUSS
= 0.4 + 0.04(15x3.28)
= 1.1312 (9.81)(3.282)(2.204)
= 263.128 N/m2
WDL
)*16pcs
Total Weight, WT = WTRUSS
= 3827 N
WDL
= 263.128 + 3827
= 4090.128 N
LIVE LOADS
WLL
9.81
1000
WIND LOAD
WW X ATRIBUTARY
= 565 Pa X 11.865 m2
WTRUSS
= 6703.725 N
Total Weight, WTRUSS
+ WTRUSS
= 263.128 + 6703.725
= 6966.853 N