GETS 806
value
OPERATING PRESSURE
DESIGN PRESSURE
OPERATING TEMPARATURE
DESIGN TEMPARATURE
Internal Diameter
Material
Max Allowable Stress
thickness calculated
head thickness
corrosion allowance
Sum
used thickness
unit
4.6 barG
6.7 barG
42 C
100 C
2610 mm
SA516 M Gr 485
138 Mpa
6.35 mm
6.33 mm
0 mm
6.35 mm
10 mm
GETS 860
value
OPERATING PRESSURE
DESIGN PRESSURE
OPERATING TEMPARATURE
DESIGN TEMPARATURE
Internal Diameter
Material
Max Allowable Stress
thickness calculated
head thickness
corrosion allowance
Sum
used thickness
unit
4 barG
6.6 barG
32 C
70 C
3400 mm
SA516 M Gr 415
118 Mpa
9.54 mm
9.51 mm
1.5 mm
11.04 mm
14 mm
GETS 870
value
OPERATING PRESSURE
DESIGN PRESSURE
OPERATING TEMPARATURE
DESIGN TEMPARATURE
Internal Diameter
unit
3 barG
15 barG
100 C
150 C
2200 mm
Material
Max Allowable Stress
thickness calculated
head thickness
corrosion allowance
Sum
used thickness
SA240 304
103 Mpa
16.16 mm
16.04 mm
1 mm
17.16 mm
28 mm
GETS 840
value
OPERATING PRESSURE
DESIGN PRESSURE
OPERATING TEMPARATURE
DESIGN TEMPARATURE
Internal Diameter
Material
Max Allowable Stress
thickness calculated
head thickness
corrosion allowance
Sum
used thickness
unit
5 barG
10 barG
44 C
110 C
1500 mm
SA516 M Gr 415
118 Mpa
6.38 mm
6.36 mm
3 mm
9.38 mm
12 mm
Name
Joint Efficiency
Internal Design Pressure
Inside Radius of Shell
Maximum Allowable Stress Value
Minimum Required thickness of shell
Symbol
E
P
R
S
t
Unit
No Unit
Mpa
mm
Mpa
mm
Calculated Values
Values
Thickness, t
Allowable Pressure, P
Symbol
E
P
R
S
t
Unit
No Unit
Mpa
mm
Mpa
mm
t
P
Torispherical Head
t
P
Value
0.85
0.67
1305
138
0
Input Values
Here. Leave
the unknown
column as
empty.
ulated Values
tial Stress (Longitudinal Joints) Longitudinal Stress (Circumferential Joints) Ellipsoidal Head thickn
mm
3.7227293629
mm
7.4582242201
Mpa
0
Mpa
Cylindrical
Shell
Calculations
Cylindrical
Shell
Calculations
Defnitions
GETS 806
value
unit
OPERATING PRESSU
4.6 barG
DESIGN PRESSURE
6.7 barG
OPERATING TEMPAR
42 C
DESIGN TEMPARATU
100 C
Internal Diameter
2610 mm
Material
SA516 M Gr 485
Max Allowable Stres
138 Mpa
thickness calculated
6.35 mm
head thickness
6.33 mm
corrosion allowance
0 mm
Sum
6.35 mm
used thickness
10 mm