Вы находитесь на странице: 1из 4

Supa8 Installation Guide

Terminals & Wiring


Terminals

Description

Earth

Panel earth connection

AC x2

16.5 VAC supply from transformer

KP

Remote codepad(s) blue wire

C
Z1-Z4

Common for Zones 1-4 (negative)


Zone 1-4 input, 4K7 end of line

C
Z5-Z8

Common for Zones 5-8 (negative)


Zone 5-8 input, 4K7 end of line

AX

Remote codepad(s) white wire

+D x2

12 VDC positive supply for detectors

-D
-D
SI
ST

12 VDC negative supply for detectors


12 VDC negative supply for detectors, also codepad(s) black wire
Siren output, 12 VDC positive when in alarm
Strobe output, 12 VDC positive when in alarm

KP+

Remote codepad(s) red wire

KYC(Molex Pin)
Keyswitch input. Apply momentary to arm or disarm the panel. Also used to restore the Installer code to factory default setting, simply power up the panel with the KY
input molex pin shorted to C. Wait 5 seconds. Remove the KY molex pin short to C. The installer code is now defaulted to 1111.

Programming
Installer Code : 1 1 1 1
Program all addresses except for address 252
Review the panel memory
Master Code : 0 0 0 0
Turn the panel on/off
Program user codes
Program the temporary telephone number
Program address 252 to restrict the installer code
Review the panel memory
Note: The master code can completely disable the Installer Code.
These codes are by factory default ONLY.

AT FIRST, SETUP:
Enter program mode, use the following addresses to setup a user passcode.
Enter Installer/Master code, then press '7'.
Now your panel is entering programming mode.
Code

Address

Notes

Master/User 0

000

Has all access to programming.

Installer/User 1

004

Has all access to programming except address 252

User 2

008

Has all access to functions except programming

User 3

012

User 4

016

User 5

020

User 6

024

User 7

028

User 8

032

User 9

036

User 10

040

User 11

044

User 12

048

User 13

052

Talk/Listen - in (V.22)

User 14

056

Home automation (V.22)

User 15

060

Turn the panel on and off at ONCE only (address 096)

Can only turn the panel on and off

*To erase a code, enter #6 within a user code address.

Second, Zone Options:


GROUP 1
Keypad Light >

Address

Delay

Siren

Dialer

AutoIsolate

Strobe

Away

Home

24 Hour

Zone 1

070

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Zone 2

072

Yes

Yes

Yes

Yes

Yes

Yes

Zone 3

074

Yes

Yes

Yes

Yes

Yes

Yes

Zone 4

076

Yes

Yes

Yes

Yes

Yes

Yes

Zone 5

078

Yes

Yes

Yes

Yes

Yes

Yes

Zone 6

080

Yes

Yes

Yes

Yes

Yes

Yes

Zone 7

082

Yes

Yes

Yes

Yes

Yes

Yes

Zone 8

084

Yes

Yes

Yes

Yes

Yes

Yes

GROUP 2
Keypad Light
>

Addres
s

Primar
y
Delay

Hom
e
Beep

Chim
e
Mode

Report
Lockou
t

Hom
e
Siren

Home
Repor
t

Home
Strob
e

Puls
e
Zone

Zone 1

224

Yes

Yes

Yes

Yes

Yes

Zone 2

226

Yes

Yes

Yes

Yes

Yes

Zone 3

228

Yes

Yes

Yes

Yes

Yes

Zone 4

230

Yes

Yes

Yes

Yes

Yes

Zone 5

232

Yes

Yes

Yes

Yes

Yes

Zone 6

234

Yes

Yes

Yes

Yes

Yes

Zone 7

236

Yes

Yes

Yes

Yes

Yes

Zone 8

238

Yes

Yes

Yes

Yes

Yes

Delays & Timers:


Address

Description

Factory Default

Min/Max Value Allowed

100

Entry Time

30 seconds

00-165 seconds

102

Exit Time

60 seconds

00-165 seconds

104

Siren Time

5 minutes

00-165 minutes

106

Test Time

00 hour

00-165 hours

246

Test Report Delay

00 hour

00-165 hours

108

Trim Time

00 minute

00-165 minutes

110

Bell Squawk Time

10 ms

00-165 milliseconds

Note: There are only 2 digits can be entered. if key inputs up over 99,
Input

Number

#1

10

#2

11

#3

12

#4

13

#5

14

#6

15

It will work as:


#1 + 5 => [10] + [5] = 105

Next up, Panel Options


Options 1 (Address 096)
Keypad Light >
Description >

Display
Lights

Quick
Away

Quick
Home

Code 15
Once

AC Fail
Delay

Quick
Review

Not
Used

Force
Arming
Squawk

Value >

Yes

Yes

Options 2 (Address 098)


Keypad Light >

Description >

Exit
Beep

Entry
Beep

Exit
Squawk

Entry
Squawk

Home
Squawk

On/Off
Squawk

Home
Instant

No Arming
if Low Bat

Value >

Yes

Yes

Yes

Setup telephone services


Dialer Options
Address

Descriptions

Factory Default

Min/Max Value Allowed

112

Temporary telephone number

nil

15 digits max

128

Telephone number 1

nil

15 digits max

144

Telephone number 2

nil

15 digits max

160

Account number 1

9999

4 digits

164

Account number 2

nil

4 digits

All telephone numbers must end with #6 to be recognised.

Dialer Options (Address 170)


Keypad Light
>

Description >

Rotary
Dial

Open Afte
r
Alarm

Not
Use
d

Not
Use
d

Not
Use
d

Send Zon
e
ID

Send Restora
l
Reports

Send Isolate
d
Reports

Value >

Yes

Other Dialer Options


Address

Description

Factory Default

Min/Max Value Allowed

168

Required Rings

15 rings

00-99 rings

175

Max Dialing Attempts

8 attempts

00-10 attempts

242

Attempts before fail to communicate

5 attempts

00-10 attempts

Dialer Reporting Format (Address 174)


Keypad Light >

none

Description >

Local, no dialer
(Factory Default)

Not
Used

Not
Used

Contact ID

Personal Dialing

Value >

Yes

General Options
Address 240

Keypad Light >

Description >

Enable External
Zones

Response
Time

Response
Time

Not
Used

Not
Used

Zone 8
Home Key

Zone 7
Siren Toggle

Yes

Yes

Value >

Response Time (Keypad light 2&3)

Keypad light >

Off

Off

On

Off

Fast Response

Off

On

Medium Response

On

On

Slow Response

Normal Response

SPECIAL FUNCTIONS, For Master Code only


Address 252

Keypad Light >

4-8

Description >

No
Installer

No Computer
Access

No Remote
Access

Value >

Вам также может понравиться