Вы находитесь на странице: 1из 1

M/s S.K. ENGINEERS,(A Unit of Sudhir Kumar Govt.

Contractor),EKTA NAGAR,Adjoining,B-31,Focal
Point,PATIALA-147001

FACTORY TEST REPORT


Dated
GROUP-I

LOT No./DOM

No. of pieces tested 40 Nos.

DIMESION & WATER ABSORPTION OF CONCRETE PAVER BLOCK OF M35,


60mm
Method of Test : IS:15658-2006
Sr.
No.

Name of Test

Water Absorption

2
3
4
5
6

Average Length (L)


Average Width(W)
Average Thickness(T)
Aspect Ratio(L/T)
Wearing Face Area
(Asw)
Arris/Chamfer (Depth)
Arris/Chamfer (Width)
Squareness (Top
Surface)
Visual Inspection

7
8
9
10
11
12

Abrasion Resistance
(mm3/mm2)
(Dry Condition)
COMPRESSIVE
STRENGTH

QC INCHARGE

CM/L No.9700000614
Result

Units

Recommended
Value

Max. 6 %
(for average)
199
166
60
4.0 (max)
75% of Plan Area
(Min.)

mm
mm
mm
mm2

Tolerance
Limit as per
IS:156582006
+2
+2
+3
-

-1%

mm
mm
mm

5 to 7
-

+1
+2

--

--

--

max30000 mm3
for 5000 mm2
N/mm2

Mini 35.0

---