Академический Документы
Профессиональный Документы
Культура Документы
CONSTRUCTION MEASUREMENT 2
TOPIC:
D E M O L I T I O N & A LT E R AT I O N
P R O J E C T:
DOUBLE STOREY OFFICE
BUILDING
GROUP 3
ITEM
UNIT
SMM
CLAUSE
DEMOLITION WORKS
1.
ITEM
C.3.1
2.
ITEM
C.3.2
3.
ITEM
C.3.2
4.
ITEM
C.3.4
5.
ITEM
C.3.6
6.
ITEM
C.3.6
7.
ITEM
C.3.4
8.
ITEM
C.3.4
NO
ITEM
UNIT
SMM CLAUSE
NEW WALL
M2
G.3.3(A)
10.
M2
G.3.3(B)
11.
M2
G.3.3(M)
12.
NO
M.20.2
13.
NO
F.18.1
14.
NO
M.19
15.
NO
F.18.1
16.
NO
M.19
17.
NO
F.18.1
18.
NO
M.21
19.
NO
F.18.1
NO
ITEM
UNIT
SMM
CLAUSE
NO
M.21
21.
NO
F.18.1
22.
NO
M.20.2
23.
NO
M.20.2
24.
PLASTERING
M2
25.
INTERNAL PAINTING
M2
U.3
26.
EXTERNAL PAINTING
M2
U.3
27.
CEMENT SCREED
M2
S.10
28.
M2
S.11
29.
CARPET
M2
S.24
QUERY LIST
NO
QUESTIONS
ASSUMPTION
1.
Size of Lintel
113mm x 225mm
2.
Type of Lintel
Precast reinforced
concrete Grade 20
3.
38mm
4.
6mm
5.
38mm
6.
Thickness of carpet
6mm
113m
m
DEMOLISH
BRICKWALL
Ref. C.3.1
a) Unit : Item
b) State :
Dimension,
Make good
113m
m
113m
m
REMOVE EXISTING
WINDOW (W2)
Ref. C.3.4
a) Unit : Item
b) State : Size,
Making good
NEW WALL
Ref. G.3
a) Unit : m2
b) State : Thickness,
Kind, Quality,
Bond, Mortar
c) Deduct lintels and
the like
(door/window)
d) G.3.3 (a)
BRICKWALL TO
FILLING EXISTING
OPENING
Ref. G.3
a) Unit : m2
b) State : Thickness,
Kind, Quality,
Bond, Mortar
c) G.3.3 (b)
BRICKWALL IN
RAISING EXISTING
STRUCTURE
Ref. G.3
a) Unit : m2
b) State : Thickness,
Kind, Quality,
Bond, Mortar
c) G.3.3 (b)
NEW GLAZED
ALUMINIUM DOUBLE
DOOR
Ref. M.20.2
a) Unit : NO
b) State : Frame,
Linings
LINTEL 1500MM
Ref. F.18.1
a) Unit : NO
b) State : Strength
required, Kind,
Quality, Size
reinforcement,
Jointing & bedding
LINTEL 1100MM
Ref. F.18.1
a) Unit : NO
b) State : Strength
required, Kind,
Quality, Size
reinforcement,
Jointing & bedding
LINTEL 1050MM
Ref. F.18.1
a) Unit : NO
b) State : Strength
required, Kind,
Quality, Size
reinforcement,
Jointing & bedding
LINTEL 800MM
Ref. F.18.1
a) Unit : NO
b) State : Strength
required, Kind,
Quality, Size
reinforcement,
Jointing & bedding
LINTEL 1950MM
Ref. F.18.1
a) Unit : NO
b) State : Strength
required, Kind,
Quality, Size
reinforcement,
Jointing & bedding
PLASTERING
Ref. S.2
a) Unit : m2
b) State : Kind of
material,
composition,
thickness,
EXTERNAL PAINTING
Ref. U.1 & U.3
a) Unit : m2
b) State : Kind of
material, No. of
coats
INTERNAL PAINTING
Ref. U.1 & U.3
a) Unit : m2
b) State : Kind of
material, No. of
coats
CEMENT SCREED
Ref. S.10
a) Unit : m2
b) State : Kind of
material,
composition,
thickness
CARPET
Ref. S.24
a) Unit : m2
b) State : Kind of
material,
dimension. Method
fixing, Nature base
SEKIAN
TERIMA KASIH