Вы находитесь на странице: 1из 3

Model

ABL8RPM24200

Defect/Symptom
Iout Failure
For verification
Verified
No test slip
Vout 28.8 Failure
Hipot
Hard Trouble

Total

No. Of Units
89
41
28
26
8
7
4
203

ABL8RPM24200 Pre and


100
90
80
70
60
50
40
30
20
10
0

Iout Failure

For verification

Verified

No test

Percent Contribution
44%
20%
14%
13%
4%
3%
2%

Pareto
44%
64%
78%
91%
95%
98%
100%

ABL8RPM24200 Pre and Post Test Repair WIP

verification

Verified

No test slip

Vout 28.8 Failure

Hipot

Hard Trouble

Remarks
Iout 25A error
red-orange (22 units) /flicker (6units)
busted capacitor C73
Burned units

st Test Repair WIP

Vout 28.8 Failure

Hipot

Hard Trouble

Action
debugged the tester
for bench test
for analysis
for bench verification
repaired
for analysis
for scrap

Вам также может понравиться