Вы находитесь на странице: 1из 1

KODE PERALATAN PLTU GRESIK

DEVICE
FUNCTION
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

DESCRIPTION
MASTER SWITCH OR RELAY
TIME DELAY STARTING OR CLOSING RELAY
CONTROL SWITCH FOR OPERATION
MASTER CONTACTOR OR RELAY
STOPPING SWITCH OR RELAY
STARTING SWITCH BREAKER CONTACTOR OR RELAY
REGULATING SWITCH
CONTROL POWER DISCONNECTING DEVICE
REVERSING SWITCH, CONTACTOR OR RELAY ON FIELD CIRCUIT
UNIT SEQUENCE SWITCH
TESTING SWITCH
OVERSPEED SWITCH OR RELAY
SYNCHRONOUS-SPEED SWITCH OR RELAY
UNDERSPEED SWITCH OR RELAY
SPEED-REGULATING SWITCH
PILOT-WIRE SUPERVISORY RELAY
PILOT WIRE RELAY
ACCELERATING OR DECCELERATING CONTACTOR OR RELAY
STARTING TO RUNNNG TRANSITION CONTACTOR OR RELAY
ELECTRICALLY OPERATED VALVE FOR AUXILIARY MACHINE
ELECTRICALLY OPERATED VALVE FOR MAIN MACHINE
( RESERVED FOR FUTURE APPLICATION )
TEMPERATURE CONTROL RELAY
TAP CHARGING MECHANICLE / OVER EXCITACY (V/F)
SYNCHRONIZING OR SYNCHRONISM CHECK DEVICE
THERMOMETER TEMPERATURE RELAY FOR STATIC MACHINE
AC UNDERVOLTAGE RELAY
ALARMING DEVICE
FIRE EXTINGUISHER
ANNOUNCIATOR RELAY
SEPARATE EXITATION CIRCUIT BREAKER, CONTACTOR OR SWITCH
DC REVERSE CURRENT RELAY
POSITION SWITCH
OPERATING SEQUENCE DEVICE
BRUSH OPERATING OR SUPPRING SHORT-CIRCUIT DEVICE
POLARITY DEVICE
UNDER CURRENT RELAY
TEMPERATURE RELAY OR BEARING
( RESERVED FOR FUTURE APPLICATION )
FIELD CURRENT RELAY OR FIELD LOSS RELAY
FIELD CIRCUIT BREAKER, CONTACTOR OR SWITCH
RUNNING CIRCUIT BREAKER, CONTACTOR OR SWITCH
MANUAL TRANSFER OR SELECTOR DEVICE
SHORT CIRCUIT DISTANCE RELAY OPR GROUND DISTANCE RELAY
DC OVER VOLTAGE RELAY
REVERSE PHASE OR PHASE BALANCE CURRENT RELAY
OPEN OR REVERSE PHASE VOLTAGE RELAY
INCOMPLETE SEQUENCE RELAY
TEMPERATURE RELAY FOR ROTATING MACHINE
SELECTIVE SHORT CIRCUIT RELAY OR SELECTIVE GROUND RELAY
INSTANT OVER CURRENT (IOC)

DEVICE
FUNCTION
NUMBER
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

DESCRIPTION
AC OVERCURRENT RELAY OR GROUND OVERCURRENT RELAY (TOC)
AC CIRCUIT BREAKER OR CONTACTOR
EXITATION RELAY
HIGH-SPEED DC CIRCUIT BREAKER
AUTOMATIC POWER FACTOR REGULATOR OR POWER FACTOR RELAY
SLIP OR OUT OF STEP PROTECTIVE RELAY ( STEP OUT RELAY )
AUTOMATIC CURRENT REGULATOR OR CURRENT RELAY
( RESERVED FOR FUTURE APPLICATION )
AC OVER VOLTAGE RELAY
AUTOMATIC VOLTAGE BALANCE REGULATOR OR VOLTAGE BALANCE RELAY
AUTOMATIC CURRENT BALANCE REGULATOR OR CURRENT BALANCE RELAY
TIME DELAY STOPPING OR OPENING RELAY
PRESSURE RELAY
GROUND OVERVOLTAGE RELAY
GOVERNOR
NOICHING RELAY
AC POWER DIRECTIONAL RELAY OR GROUND DIRECTIONAL RELAY
DETECTOR FOR RUNNING
FLOW RELAY
RHEOSTAT MANUALLY OR POWER OPERATED
FAULT DETECTOR FOR RECTIFIER ELEMENT
DC CIRCUIT BREAKER OR CONTACTOR
SHORT-CIRCUIT BREAKER OR CONTACTOR FOR RUNNING RESISTOR
REGULATING VALVE
BREAKING DEVICE
DC OVER CURRENT RELAY
REGULATOR FOR LOAD
PHASE COMPARISON RELAY OR CANSILS CURRENT PROTECTION
DC RECLOSING RELAY
DC UNDER VOLTAGE RELAY
DRVIND APPARATUS FOR GOVERNOR
DC RECLOSING RELAY
SELECTIVE CONTROL CONTACTOR SWITCH OR RELAY
VOLTAGE RELAY
SIGNAL RELAY
LOCKING OUT RELAY
DIFFERENTIAL CURRENT RELAY
CONTACTOR OR SWITCH FOR AUXILIARY MACHINE
DISCONNECTING SWITCHLINE SWITCH, AC OR DC REGULATOR
AUTOMATIC VOLTAGE OR CURRENT REGULATOR
AUTOMATIC POWER REGULATOR OR POWER RELAY
DOOR
( RESERVED FOR FUTURE APPLICATION )
TRIP-TREE CONTACTOR OR RELAY
AUTOMATIC FREQUENCY REGULATOR OR FREQUENCY RELAY
INTERNAL FAULT DETECTOR FOR STATIONARY EQUIPMENT
SUNNER
COUPLING
AUTOMATIC RECLOSING DEVICE