Академический Документы
Профессиональный Документы
Культура Документы
IMPROVEMENT IN
THERMAL POWER PLANT
HEAT RATE
Heat rate is heat input required per unit of
power generated(kcal/kWh), for specific fuel
conditions and specific site conditions.
LOSSES
Throttle Pressure
Throttle Temperature
Hot Reheat Temperature
Condenser Pressure
Makeup Flow
Feedwater Heater Drain Cooler
Approach Temperature
PARAMETERS TO BE
OBSERVED
1. BOILER-WATER/STEAM
SIDE
Steam Temperatures
a) Final Superheat outlet
temperature
b) Hot Reheat outlet temperature
Attemperation Flows
a) Reheat
b) Superheat
FW temperature at economizer outlet
3. PULVERIZER
Mill outlet temperatures
Ratio of mill amps to coal flow
Tempering air
4. FEED WATER
TEMPERATURE
Terminal Temperature Differences
Drain Cooler Approaches
Feed water temperature at HPH
outlet
Heater level
Heater vent positions
6. OTHERS
ROAD BLOCKS
Recommendations
Flexibility in scheduling of LRSB
Provision of remote Wall blowing
from UCB
Regular checks on
Locking of peep holes
Leakage in steam traps