Вы находитесь на странице: 1из 2

SHIELDTM

WATER HEATER
Submittal Sheet
SWH-Sub-02a
SHIELD COMMERCIAL GAS WATER HEATER
JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
RECOVERY RATE IN GPH_______________________________________@_________F RISE
NOTES

Standard Features

Optional Equipment

96% Thermal Efficiency


Modulating Burner with 5:1 Turndown
Operates at Temperatures up to 180F for Sanitizing Applications
Stainless Steel Heat Exchanger
160 PSI Working Pressure
ASME Tank Construction (SNA285500)
Glass-Lined Steel Tank
Brass Drain Valve
PVC, CPVC and SS Venting up to 100 Equivalent Feet
Direct-Vent Sealed Combustion
Rooftop and Sidewall Venting
Factory Supplied Sidewall Vent Termination
Advanced Electronic Control, with:
- 2-Line, 16-Character LCD Display
- Time Clock
- Night Setback
- Alarm Contacts
- Runtime Contacts
- Manual Reset High Limit
Low-NOx Operation
Zero Clearance to Combustibles
Low Gas Pressure Operation
Direct-Spark Ignition
Certified for Installation on Combustible Floors
ASME Temperature and Pressure Relief Valve
8-Foot Power Cord
3-Year Limited Warranty
1-Year Parts Warranty
(see warranty for details)

Place an X in the box by all options that apply

Alarm Bell
Concentric Vent Kit
Condensate Neutralization Kit
Low Water Cutoff

SHIELD Commercial Gas Water Heater Dimensions & Specifications

Model Btu/hr Capacity GPH @ First


Number Input (Gal) 100 Rise Hour A

SNR150-100
SNR200-100
SNA285-125
SNA400-125
SNA500-125

28"
28"
34"
34"
34"

44"
44"
32-3/4"
32-3/4"
32-3/4"

61-1/4"
61-1/4"
52-3/4"
52-3/4"
52-3/4"

150,000
199,999
285,000
399,999
500,000

93
93
125
125
125

175
233
332
465
582

249
307
432
565
682

80"
80"
80"
80"
80"

F
73-3/4"
73-3/4"
75"
75"
75"

62-1/2"
62-1/2"
53"
53"
53"

68-3/4"
68-3/4"
59-3/4"
59-3/4"
59-3/4"

72-3/4"
72-3/4"
73-1/4"
73-1/4"
72"

74-1/4"
74-1/4"
70-1/2"
73-1/4"
75"

Gas Water Air Vent Shipping


Conn. Conn. Inlet Size Wt. (lbs.)
1/2"
1/2"
3/4"
1"
1"

1-1/2"
1-1/2"
2"
2"
2"

3"
3"
4"
4"
4"

3"
3"
4"
4"
4"

700
725
800
850
875

Change "N" to "L" for LP Gas. All information is subject to change. Electrical Requirements: 120VAC/60Hz/1 phase

HLW

Lochinvar, LLC 300 Maddox Simpson Pkwy Lebanon, TN 37090 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
7/12Printed in U.S.A.