QUESTION: 1
When installing a CallPilot system using a 201i server and a CS 1000 system, how
do you connect the SCSI connection to the server?

A. by using the low profile right-angle SCSI connector on the NTRH3502SCSI cable
attached to the SCSI connector on the 201i server faceplate
B. by using the backplane connector in the Media Gateway or Media Gateway
Expansion with the multi I/O cable (NTRH0912) to the next device in the SCSI chain
C. by using the CD-ROM drive SCSI cable NTRH1408 attached from the SCSI
connector on the 201i server faceplate to the SCSI adapter A0763912 on the CD-
ROM drive
D. by using the Intermediate SCSI cable NTRH1408 that connects from the SCSI
connector on the 201i server faceplate to the I/O panel connector and the NTRH1410
SCSI cable

Answer: A

QUESTION: 2
When configuring the switch to support CallPilot services, which programming can
you perform to provide for uninterrupted call processing in case the link or CallPilot
is disabled?

A. At the Night Call Forward (NCFW) prompt, forward the primary Control
Directory Number to the attendant.
B. At the Night Call Forward (NCFW) prompt, forward the primary Control
Directory Number (CDN) to a secondary CDN.
C. At the Local Default ACD DN (DFDN) prompt, direct all Control Directory
Numbers to an appropriate phantom directory number depending on media type
required.
D. At the Local Default Automatic Call Distribution directory number (DFDN)
prompt, direct all the CallPilot associated Control Directory Numbers to a Default
ACD DN, typically an attendant.

Answer: D

QUESTION: 3
You are preparing to set up, install, and configure a CallPilot system. There are
several tasks involved with any server installation. Several guidelines should be
followed whenever handling switch and server components. What are three
guidelines? (Choose three.)

A. Use electrostatic discharge precautions.


B. Hard drives do not need special handling.

http://www.testkiller.com
2 http://www.troytec.com
920-162

C. Do not slide printed circuit boards on any surface.


D. Use firm and steady force to seat printed circuit boards.
E. Handle printed circuit boards by the backplane edge connector.

Answer: A, C, D

QUESTION: 4
During installation you prepare to connect the 703t server to the ELAN. One end of
the cable connects to the server. Where do you connect the other end of the cable?

A. the ELAN hub


B. the CLAN hub
C. the ELAN gateway
D. the customer router

Answer: A

QUESTION: 5
The CallPilot 703t server has one MPB96 card. The PBX it is connecting to will
require Mgate cards. How many MGate cards are needed to support 80 voice
channels?

A. 1 MGate cards
B. 2 MGate cards
C. 3 MGate cards
D. 4 MGate cards

Answer: C

QUESTION: 6
The CallPilot TRP server has been connected to a PBX. The server should have
several devices connected to it, e.g., the PBX. These devices must all be connected to
the same ground. What are three of these devices? (Choose three.)

A. modem
B. MGate card
C. server monitor
D. CallPilot Manager standalone web server
E. ELAN switch/hub and optional CLAN switch/hub

http://www.testkiller.com
3 http://www.troytec.com
920-162

Answer: A, C, E

QUESTION: 7
Click the Exhibit button. Prior to installing a CallPilot system, you review the
Configuration Wizard worksheet. The customer has provided category 5 cable
connections to their corporate LAN for the Switch Ethernet connection, the CallPilot
Server Customer LAN (CLAN) Ethernet connection, and the CallPilot Server
Embedded LAN (ELAN) Ethernet connection. The network address information
(shown in the exhibit) for the Switch IP address, the CallPilot Server ELAN IP
address, and the CallPilot Server CLAN IP address integrate with the customer's
internal network. What action would you take?

A. Proceed with the installation using the category 5 cable connections, IP addresses
and Subnet masks provided by the customer.
B. Proceed with the installation, but use a separate category 5 cable that connects
directly from the switch to the ELAN network interface connector on the server.
C. Inform the customer that IP addresses beginning with 192.168 are private
addresses and if used the ELAN will not be able to be connected to the Internet.
D. Inform the customer that the ELAN must be on a separate IP network isolated
from the CLAN, and recommend they use a dedicated hub for the ELAN, and
different IP addresses for the switch and the ELAN NIC.

Answer: D

QUESTION: 8
On a 1001rp running CallPilot release 2.0, which three checks does the Upgrade
Wizard perform? (Choose three.)

A. checks the software version


B. checks for the correct 4.0 Image CD
C. checks for the correct RAID firmware
D. checks that the data in the database is valid
E. checks that the database and computer names are in sync

http://www.testkiller.com
4 http://www.troytec.com
920-162

Answer: A, D, E

QUESTION: 9
Click on the Exhibit button. You are installing a CallPilot 201i server in a Meridian 1
Option 51C switch. You connect the 50-pin Amphenol connector on the multi I/O
cable (NTRH0912) to the newly installed backplane cable (NTRH3501) on the I/O
panel at the rear of the switch. Where will you connect the Embedded LAN (ELAN)
connector on the multi I/O cable?

A. Connect the ELAN connector on the multi I/O cable (NTRH0912) to the ELAN
hub.
B. Connect the ELAN connector on the multi I/O cable (NTRH0912) directly to a
hub or router on the Customer's LAN (CLAN).
C. Connect the ELAN connector on the multi I/O cable (NTRH0912) directly to the
Ethernet transceiver at the rear of the switch cabinet.
D. Connect the ELAN connector on the multi I/O cable (NTRH0912) to the RJ-45
female-to-female gender change jack and a cross-over network cable.

http://www.testkiller.com
5 http://www.troytec.com
920-162

Answer: A

QUESTION: 10
You are preparing to set up, install, and configure a CallPilot system. There are
several tasks involved with any server installation. General safety precautions should
always be followed. What are three precautions? (Choose three.)

A. Use extension cords as needed.


B. Always use grounded power systems.
C. Never power-down equipment to service it.
D. Use a surge protector or uninterruptible power supply.
E. Ensure peripheral cables are protected and out of the way.

Answer: B, D, E

QUESTION: 11
You are preparing to set up, install, and configure a CallPilot system. There are many
considerations for power requirements. Nortel has two rules that apply to power
requirements. What are the two rules? (Choose two.)

A. The power can originate from any service panel.


B. The electrical service panel can be used for any electrical device.
C. The electrical service panel must not be used for lights or motors.
D. All power for the CallPilot must originate from the same service panel.

Answer: C, D

QUESTION: 12
The CallPilot Server comes pre-loaded with Windows Server 2003 and CallPilot
Manager among other software. You are Logging on to the server for the first time.
What is the first wizard that should be run?

A. Setup Wizard
B. Upgrade Wizard
C. Configuration Wizard
D. Windows Server 2003 Wizard

Answer: A

http://www.testkiller.com
6 http://www.troytec.com
920-162

QUESTION: 13
A field engineer working on a CallPilot system at a customer's site needs to install
Performance Enhancement Packages (PEPs) on the CallPilot server. In what order
must the field engineer install the PEPs?

A. Install the component A PEP followed by the component S PEP.


B. Install PEPs from the highest PEP number to the lowest PEP number.
C. Install PEPs from the lowest PEP number to the highest PEP number.
D. Install PEPs from the lowest PEP number to the highest PEP number unless
otherwise specified in the Read Me files.

Answer: D

QUESTION: 14
You are upgrading a 201i to CallPilot 4.0. The image installs but the system hangs
when booting into Windows 2003. What two items do you need to check? (Choose
two.)

A. The BIOS has been upgraded to 6.0.3.


B. The keyboard and mouse are plugged in correctly.
C. The external CD-ROM and Tape drive are connected.
D. The BIOS option for Operating System type is set to 'other'.

Answer: A, D

QUESTION: 15
A field engineer working on a CallPilot system at a customer's site needs to uninstall
Performance Enhancement Packages (PEPs) on the CallPilot server. How would the
field engineer view all installed PEPs and remove a desired PEP?

A. through the DMI Viewer, select Show Suites, select Read, and click on Remove
B. through the DMI Viewer, click on show PEPs, select the PEP, and click on
Remove
C. through the DMI Viewer, click on Show Suites, select the PEP and click on
Uninstall
D. under Add/Remove Programs, click on view PEPs, select the PEP, and click on
Uninstall

Answer: B

QUESTION: 16
A customer is upgrading a CallPilot 703t server from CallPilot release 2.02 to 4.0.

http://www.testkiller.com
7 http://www.troytec.com
920-162

What are the steps that need to be performed in order to upgrade the server?

A. Install CallPilot 4.0 image -> Setup Wizard -> Config Wizard
B. Upgrade Wizard -> Install CallPilot 4.0 image -> Config Wizard
C. Upgrade Wizard -> Install CallPilot 4.0 image -> Setup Wizard ->
Config Wizard
D. Migration Wizard -> Install CallPilot 4.0 image -> Setup Wizard ->
Config Wizard

Answer: C

QUESTION: 17
The Setup Wizard indicates a problem validating the system data. Where should a
technician look first to try and identify the problem?

A. Setup Log
B. System Log
C. Backup Log
D. CallPilot Log

Answer: D

QUESTION: 18
You are provisioning the Embedded Local Area Network (ELAN) on a Meridian 1
switch at a site where the customer has a Symposium 4.2 call center. The customer
will also use the CallPilot Symposium Voice Services Support feature. What
exception or additional step is required for the Symposium Voice Services Support
feature?

A. In overlay (LD) 15, Internal/external definition (IDEF) must be set to "YES".


B. In overlay (LD) 16, Internal/external definition (IDEF) must be set to "LOC".
C. In overlay (LD) 17, Security for Meridian Link Applications (SECU) must be set
to "YES".
D. In overlay (LD) 117, provision an additional host entry for the Symposium Call
Center Server by entering the command: NEW HOST NAME xxx.xxx.xxx.xxx
(where NAME is the host name for the SECC server, and xxx.xxx.xxx.xxx is the
ELAN IP address for the SECC server).

Answer: C

QUESTION: 19
When installing a CallPilot system using a 201i server and a Meridian 1 Option 11C

http://www.testkiller.com
8 http://www.troytec.com
920-162

Mini switch, how should you set the SCSI ID on the Tandberg SLR5 tape drive
(NTRH9038)?

A. Rotate the dial on the SCSI ID rotary switch until the arrow points to 3.
B. Use the blade of a screwdriver to set the DIP switches as follows: 1=On, 2=Off,
3=Off, 4=Off, 5=Off
C. Use the blade of a screwdriver to press either the plus (+) or minus (? button on
the SCSI ID switch to set the SCSI ID to 5.
D. The SCSI ID for the Tandberg SLR5 tape drive (NTRH9038) is set when you run
the Configuration Wizard after you install the CallPilot system.

Answer: C

QUESTION: 20
The CallPilot 703t servers are standalone systems. The 703t systems interface the
Meridian 1 and Succession 1000 PBX switches using three specific hardware
components for multimedia connectivity. What are the three hardware components?
(Choose three.)

A. MGate card
B. DS30X cable
C. MPB96 board
D. MPB16-4 board
E. NTRH0912 multi I/O cable

Answer: A, B, C