ELECTRICAL LEGEND

SYMBOL

DESCRIPTION

SYMBOL

DEVICE FURNISHED AND INSTALLED UNDER OTHER DIVISIONS.


RACEWAY (TRUNKING/TRAY) AND CONDUCTORS FURNISHED AND
INSTALLED UNDER THIS SECTION. CONDUCTOR TERMINATIONS
UNDER OTHER DIVISIONS

CIRCUIT BREAKER MEDIUM VOLTAGE, DRAW-OUT TYPE


XXX = AMPS FRAME SIZE

XXX

ISOLATOR MEDIUM VOLTAGE, DRAW-OUT TYPE


SURGE ARRESTOR

EQUIPMENT TAG NUMBER

CAPACITOR-KVA INDICATED, 3 PHASE UNLESS OTHERWISE INDICATED

10

MAJOR ELECTRICAL EQUIPMENT OR DEVICE, I.E., MOTOR CONTROL


CENTER, SWITCHBOARD, ETC

METER WITH SWITCH (V=VOLTMETER, A=AMMETER)


SWITCH AND SCALE RANGE AS INDICATED

V
0-600

GROUND (EARTH)

PANELBOARD - SURFACE OR FLUSH MOUNTED AS INDICATED


X

TERMINAL JUNCTION BOX (TJB). SURFACE OR FLUSH


MOUNTED AS INDICATED

ABBREVIATIONS

DESCRIPTION

CONNECTION POINT TO EQUIPMENT SPECIFIED, SUPPLIED, AND


INSTALLED UNDER OTHER DIVISIONS. RACEWAY (TRUNKING/TRAY),
CONDUCTORS AND CONNECTIONS UNDER THIS DIVISION.
XX

ABBREVIATIONS

IEEE DEVICE FUNCTION/LEGEND


DEVICE
FUNCTION
NO.

DESCRIPTION

15/25A/60

AUTOMATIC SYNCHRONIZER W/VOLTAGE


AND FREQUENCY MATCHING

25
26

OVER TEMPERATURE

27

UNDERVOLTAGE RELAY

10KV

27/59/T
MOTOR CONNECTION. FOR KW SIZE, REFER TO ONE-LINE DIAGRAM
OR EQUIPMENT SCHEDULE

EMERGENCY/STANDBY ENGINE GENERATOR. RATING AS INDICATED


ON ONE-LINE DIAGRAM

TRANSFORMER
KVA, PRIMARY & SECONDARY VOLTAGE INDICATED
380Y/220V

NOTE:
IT IS UNDER THE VENDORS RESPONSIBILITY AND SCOPE OF WORK TO CHECK GIVEN MEASUREMENTS AND ELEVATIONS ON SITE BEFORE PREFABRICATION!!

A0

AUTOMATIC TRANSFER SWITCH


CONTINUOUS CURRENT RATING AS INDICATED

RECEPTACLE (SOCKET OUTLET), SPECIAL PURPOSE NEMA CONFIGURATION


AND AMPERAGE AS INDICATED

INSTRUMENTATION VOLTAGE TRANSFORMER


RATIO, QUANTITY, AND CONNECTION INDICATED

4:1

TWIN CONVENIENCE RECEPTACLE (SOCKET OUTLET)

CURRENT TRANSFORMER. RATIO & QUANTITY INDICATED

400:5

WALL SWITCH, SUBSCRIPT INDICATES TYPE:


2 = DOUBLE POLE
LV = LOW VOLTAGE
3 = THREE WAY (TWO WAY)
P = PILOT LIGHT
4 = FOUR WAY (INTERMEDIATE)
K = KEY OPERATED
D = DIMMER
WP = WEATHER PROOF
M = MANUAL MOTOR STARTER SWITCH
X = HAZARDOUS RATED
* LOWER CASE LETTER DENOTES SWITCH LEG

30

NONFUSED DISCONNECT SWITCH, AMPERAGE INDICATED; "ON-LOAD" RATED

40
63

FUSED DISCONNECT SWITCH (40/63, 40 = FUSE AMPERAGE,


63 = SWITCH AMPERAGE); "ON-LOAD" RATED

100
125

CB

GROUND SENSOR CURRENT TRANSFORMER. RATIO & QUANTITY INDICATED

800:5
(?)

INDICATING LIGHT, WALL MTD, LETTER INDICATES COLOR


(A=AMBER, G=GREEN, R=RED)

A
PUSH-TEST
R

REVERSE POWER RELAY

40

LOSS OF FIELD RELAY

46N

NEGATIVE SEQUENCE RELAY

47

PHASE SEQUENCE VOLTAGE RELAY

49

THERMAL RELAY
INSTANTANEOUS AND TIME
OVERCURRENT RELAY

51N

EARTH FAULT RESIDUAL CURRENT RELAY

51V

TIME OVERCURRENT RELAY WITH


VOLTAGE RESTRAINT

52

CIRCUIT BREAKER (M=MAIN, F=FEEDER)

59

OVERVOLTAGE RELAY

65E
67

INDICATING LIGHT, PUSH-TO-TEST, LETTER INDICATES COLOR


(A=AMBER, G=GREEN, R=RED)

ENCLOSED CIRCUIT BREAKER WITH SHORT CIRCUIT AND OVERCURRENT


PROTECTION. SEE SPECIFICATION FOR TYPE OF TRIP. (100/125,
100 = TRIP AMPERAGE, 125 = FRAME AMPERAGE); "ON-LOAD" RATED

INDICATING LIGHT, PANEL MTD, LETTER INDICATES COLOR


(A=AMBER, G=GREEN, R=RED)

X00

ENCLOSED STARTER, SIZE INDICATED; "ON-LOAD" RATED


000

3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS


X=CLOSED CONTACT
O=OPEN CONTACT

AC DIRECTIONAL OVERCURRENT RELAY


AC GROUND
DIRECTIONAL OVERCURRENT RELAY

81O

OVERFREQUENCY RELAY

81U

UNDERFREQUENCY RELAY

81O/U

ELECTRONIC GOVERNOR

67N

ENCLOSED CONTACTOR, AMPERAGE INDICATED; "ON-LOAD" RATED

32

RESISTOR

30

ANNUNCIATOR

50/51
(?)

30

CONVENIENCE RECEPTACLE (SOCKET OUTLET), PEDESTAL, TWIN SINGLE


FACE, TWIN WITH TELEPHONE OR DATA AS INDICATED
32A 3PH

UNDER/OVER VOLTAGE RELAY


WITH ADJUSTABLE TIMER

500 KVA

400

WP=WEATHER PROOF, GFCI=GROUND FAULT CIRCUIT INTERRUPTER,


IG=ISOLATED GROUND, X=HAZARDOUS RATED

SYNCHRONIZING CHECK RELAY

OVER/UNDERFREQUENCY RELAY

86

TRIP LOCKOUT RELAY

87

DIFFERENTIAL PROTECTIVE RELAY

87B

BUS DIFFERENTIAL RELAY

ENCLOSED STARTER, COMBINATION, SIZE INDICATED; "ON-LOAD" RATED

CONTROL STATION

OFF

JUNCTION BOX, SURFACE MOUNTED UNLESS OTHERWISE NOTED.


J = FLOOR
J = WALL

90

00X

ON

0X

SELECTOR SWITCH, MAINTAINED CONTACTS


X=CLOSED CONTACT
O=OPEN CONTACT

VOLTAGE REGULATOR

90P

VAR/PF CONTROL

90F

FORCED FIELD EXCITATION REGULATOR

94

TRIPPING RELAY

MULTI-SOCKET OUTLET ASSEMBLY


?

NORMALLY OPEN I/O CONTACT WITH ADDRESS

CABLE TRAY, TROUGH TYPE

#
I/O

CONDUCTOR COLOR CODES

CABLE TRAY, LADDER TYPE

NORMALLY CLOSED I/O CONTACT WITH ADDRESS


#

UP

#
I/O

ANGLED LADDER CABLE TRAY WITH HINGED SPLICE PLATES

NORMALLY OPEN RELAY CONTACT


#

OVERHEAD CONDUIT RACK

#
?

NORMALLY CLOSED RELAY CONTACT


#

UNDERSLAB OR BELOW GRADE CONDUIT DUCT BANK

#
O
?
?

CABLE TRENCH

OVERCURRENT DEVICE (OCD), OVERCURRENT RELAY (OCR) OR


OPEN-PHASE DETECTION RELAY (OPD)

FEEDER BUS DUCT (BUS BAR TRUNKING)


RATINGS PER SPECIFICATIONS AND/OR ONE-LINE DIAGRAM

DELTA-WYE

WIREWAY, AUX GUTTER, OR TRUNKING


40
F 63

PQM

40 CB
63

POWER QUALITY MONITOR (PQM)

PLUG-IN BUS DUCT (BUS BAR TRUNKING)


PLUG-IN DEVICE TYPE & RATING PER SPECS AND/OR ONE-LINE DIAGRAM

BRANCH CIRCUIT HOME RUN TO PANELBOARD

DM

DISPLAY METER (DM)

AFD

ENCLOSED STARTER, ADJUSTABLE FREQUENCY DRIVE (AFD)

OL

CONDUIT AND CONDUCTORS OR CABLES CONCEALED IN FINISHED


SPACES AND EXPOSED ELSEWHERE UNLESS OTHERWISE INDICATED

H1

H2

MOTOR OVERLOAD

CONDUIT AND CONDUCTORS OR CABLES BELOW GRADE OR SLAB


CONDUIT UP & DOWN

CONDUIT DOWN

?VA
?V
?
?

#
X1

X2

CONTROL POWER TRANSFORMER

CONDUCTOR

COLOR

PHASE R (A)

BROWN

PHASE S (B)

BROWN W/BLACK LABEL

PHASE T (C)

BROWN W/ORANGE LABEL

NEUTRAL

BLUE

GROUND

GREEN/YELLOW

SWITCHLEG (LTG)

PHASE COLOR

DC POSITIVE

RED

DC NEGATIVE

BLACK

DESCRIPTION

A, AMP
AB
AC
ACB
AF
AFD
AFF
AIC
ANN
ARF
AS
AT
ATS
ATX
AWA

AMMETER, AMPERE
ABSOLUTE
ALTERNATING CURRENT
AIR CIRCUIT BREAKER
AMPERE FRAME
ADJUSTABLE FREQUENCY DRIVE
ABOVE FINISHED FLOOR
AMPS INTERRUPTING CURRENT
ANNUNCIATOR
ABOVE RAISED FLOOR
AMMETER SWITCH
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AUTO TRANSFORMER
ALUMINUM WIRE ARMORED

B
BC
BFF
BG
BKR
BLDG
BMS
BOC
BOD
BOP
BOT
BRN
BT

BELL
BARE COPPER
BELOW FINISHED FLOOR
BULK GAS
BREAKER
BUILDING
BUILDING MANAGEMENT SYSTEM
BOTTOM OF CONDUIT
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM OF TRAY OR TRUNKING
BUS REFERENCE NO.
(ENGINEERING STUDY USE)
BASIC TRANSPONDER

C
CAP.
CAT.
CB
CC
CCTV
CCT
CLK
CO
CONT
CPT
CR
CRE
CRS
CRWP
CS
CT
CU
CUB.

CONDUIT
CAPACITOR
CATALOG
CIRCUIT BREAKER
CONTROL CABLE
CLOSED CIRCUIT TELEVISION
CIRCUIT
CLOCK
CONDUIT ONLY
CONTINUED
CONTROL POWER TRANSFORMER
CONTROL RELAY
CORROSION RESISTANT
COATED RIGID STEEL CONDUIT
CLEANROOM WALL PANEL
CONTROL SWITCH
CURRENT TRANSFORMER
COPPER
CUBICLE

D
DB
DC
DDC
DIA
DIV

DUCT
DUCT BANK
DIRECT CURRENT
DIRECT DIGITAL CONTROL
DIAMETER
DIVISION
DELTA CONNECTED

E
EMPTY
(E), EX EXISTING
ECS
EMERGENCY COMMAND STATION
EDF
ELECTRIC DRINKING FOUNTAIN
EG
ENGINE GENERATOR
EL
ELEVATION
ELEC
ELECTRICAL
EM,EMEREMERGENCY
EMH
ELECTRICAL MANHOLE
EMO
EMERGENCY MANUAL OFF
EMT
ELEC METALLIC TUBING
ENT
ELEC NON-METALLIC TUBING
EOL
END-OF-LINE DEVICE
ERT
EMERGENCY RESPONSE TEAM
ESES
EMER SERVICE ENTRANCE SUBSTATION
ET
EXPANDED TRANSPONDER
ETC
ETCETERA
ETM
ELAPSED TIME METER
EWC
ELECTRIC WATER COOLER
EXP
EXPLOSION PROOF
49
F
(F)
FA
FACP
FBO
FCS
FDR
FLR
FOL
FU
FWS
FVNR
FVR

(FORTY NINE) OVERTEMP RELAY


FLUSH
FUTURE
FIRE ALARM
FIRE ALARM CONTROL PANEL
FURNISHED BY OTHERS
FACILITY CONTROL SYSTEM
FEEDER
FLOOR
FAST ACTING OL RELAY
FUSE
FIRE WATER STORAGE
FULL VOLTAGE NON-REVERSING
FULL VOLTAGE REVERSING

GND
GEN
GFCI
GFR
GSM

GROUND
GENERAL
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT RELAY
GAS SAFETY MONITOR

H
HH
HID
HOA
HVAC
HB

HORN
HANDHOLE
HIGH INTENSITY DISCHARGE
HAND-OFF-AUTOMATIC
HEATING, VENTILATING & AIR
CONDITIONING
HORIZONTAL BEND

ICCB
I.D.
IER
I&C
IMC
I/O
IP
IPS
IS

INSULATED CASE CIRCUIT BREAKER


IDENTIFICATION
INTEGRATED EQUIPMENT RATING
INSTRUMENTATION AND CONTROL
INTERMEDIATE METALLIC CONDUIT
INPUT/OUTPUT
DEGREE OR ENCLOSURE PROTECTION
INTERRUPTABLE POWER SUPPLY
CURRENT SWITCH

JUNCTION BOX

K
kV
kVA
kVAR
kW
kWH
kWHD

KEY INTERLOCK
KILOVOLT
KILOVOLT-AMPERE
KILOVAR
KILOWATT
KILOWATT HOUR
KILOWATT HOUR DEMAND

L
LAN
LC
LS
LTG
LV

LEFT
LOCAL AREA NETWORK
LIGHTING CONTACTOR
LEVEL SWITCH
LIGHTING
LOW VOLTAGE

ABBREVIATIONS
M
MAX
MBS
MCB
MCC
MCCB
MCP
MDC
MFR
MH
MIN
MLO

MAG CONTACTOR, COIL OR CONTACT


MAXIMUM
MAINTENANCE BYPASS SWITCH
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOLDED CASE CIRCUIT BREAKER
MOTOR CIRCUIT PROTECTOR
MOTORIZED DAMPER CONTROL
MANUFACTURER
MANHOLE
MINIMUM
MAIN LUGS ONLY
SQUARE MILLIMETERS
MMP
MECHANICAL MOUNTING PANEL
MO
MOTOR OPERATOR
MS
MOTOR STARTER
MSP
MOTOR STATER PANEL
MT,MTD MOUNT, MOUNTED
(N)
N
NA
N.C.
N.E.
NEC
NIC
NL
N.O.
NP
NTS
N.W.

NEW
NEUTRAL
NON-AUTOMATIC
NORMALLY CLOSED
NORTH EAST
NATIONAL ELECTRICAL CODE
NOT IN CONTRACT
NIGHT LIGHT
NORMALLY OPEN
NAMEPLATE
NOT TO SCALE
NORTH WEST

OFCI

OWNER FURNISHED, CONTRACTOR


INSTALLED
OWNER FURNISHED, OWNER
INSTALLED
OVERLOAD RELAY
ON-OFF
ON-OFF-AUTO
ON-OFF-REMOTE
OPEN POLE DETECTOR

OFOI
OL
OO
OOA
OOR
OPD
P
PF
PL
PB
PC
PCP
PIN
PIV
PM
PNL
PQ

GENERAL NOTES

DESCRIPTION

ELECTRICAL PANEL NUMBERING SYSTEM


2 - F1AA12 E F 020

THIS IS A STANDARD LEGEND SHEET. SOME SYMBOLS OR ABBREVIATIONS MAY APPEAR ON


THIS SHEET AND NOT ON THE PROJECT DRAWINGS.

CONDUCTORS SIZED ON THE BASIS OF XLPE INSULATED COPPER TO IEC 502. MAXIMUM

MOUNTING PER SPECIFICATIONS UNLESS OTHERWISE INDICATED.

EQUIPMENT IS GENERAL PURPOSE PER SPECIFICATION UNLESS OTHERWISE INDICATED AS


FOLLOWS: X=EXPLOSION PROTECTED, EX CLASSIFICATION PER IEC 79
WP=WEATHERPROOF, IP CLASSIFICATION PER IEC 529.

SEE ELEMENTARY DIAGRAMS FOR OPERATIONAL SCHEMATICS.

LUMINAIRE SYMBOLS SHOWN ARE GENERIC GRAPHIC REPRESENTATIONS. REFER TO


LUMINAIRE SCHEDULE FOR SPECIFIC SOURCE, TYPE & MOUNTING.

SYSTEMS INCLUDING ELECTRICAL CIRCUITS SHOULD BE TESTED BY AUTHORIZED INTEL


INSPECTOR ("BODEK").

CONSTRUCTION DETAILS SHOWN ON THE 7600 SERIES DRAWINGS SHOW TYPICAL


INSTALLATION UNLESS OTHERWISE NOTED, AND APPLY TO ELECTRICAL WORK INCLUDED IN
THE SUMMARY OF WORK FOR THIS PACKAGE EVEN THOUGH NOT SPECIFICALLY
REFERENCED ON THE PLAN DRAWINGS.

IN EXISTING DISTRIBUTION BOARD, WHERE PLUG-IN CIRCUIT BREAKER TYPE IS REQUIRED,


THE BASE OF THE CIRCUIT BREAKER IS ALREADY INSTALLED.

ACQUIRE AMC APPROVAL FOR EQUPIMENT THAT IS TO BE LOCATED IN THE CLEAN AIR
STREAM.

PROVIDE UV PROTECTION FOR EQUIPMENT LOCATED OUTDOORS.

PROVIDE TYPE C MINICIRCUIT BREAKER FOR EQUIPMENT FED FROM BRANCH PANELS
UNLESS OTHERWISE NOTED.

CABLES BELOW 50 SQUARE MILLIMETERS ROUTED IN TRAY TO BE FIELD ROUTED.

FOR CIRCUITS REQUIRING PENETRATIONS, VERIFY FIRE RATING OF ASSEMBLY. APPLY FIRE
STOPPING AS REQUIRED PER SPECIFICATION 07_84_00_00(07840).

SEQUENTIAL PANEL NUMBER 1 THRU 999


EQUIPMENT TYPE
F = 400V FACILITIES DISTRIBUTION PANEL
L = 400/230V FACILITIES LIGHTING & RECEPTACLES
M = 400V MOTOR CONTROL CENTER
S = 400V TOOL DISTRIBUTION PANEL
X = 208V TOOL DISTRIBUTION PANEL
Z = 480V TOOL DISTRIBUTION PANEL
T = 208V/120V TRANSFORMER
H = HEAT TRACE PANEL
SERVICE
E = EMERGENCY
N = NORMAL
C = CPS

LOCATION (NORTH\EAST CORNER)


-AA12

PVC

POWER
POWER FACTOR
PILOT LIGHT
PUSHBUTTON SWITCH
PHOTOCELL
PLANT CONTROL PANEL
PERSONAL ID NUMBER
POST INDICATOR VALVE
POWER MONITOR
PANEL
POWER QUALITY
PHASE
POLYVINYL CHLORIDE

QTY

QUANTITY

R
(R)
RCPT
RCY
(RD)
RF
RGS
RM
RMS
RQD
RTM
RVNR
RVR
RVSS

RATE OF RISE, RIGHT


RELOCATE
RECEPTACLE
RACEWAY
REDUNDANT
RADIO FREQUENCY
RIGID GALVANIZED STEEL
ROOM
ROOT MEAN SQUARE
REQUIRED
RUNNING TIME METER
REDUCED VOLTAGE NON-REVERSING
REDUCED VOLTAGE REVERSING
REDUCED VOLTAGE SOFT START

S
S.C.
SCP
S.E.
SEC
SES
SFEP
SO
SOL
SP
SS
STBY
STC
STD
SUB
SUPP
SUR
SW
S.W.
SWA
SWBD
SWGR
SYM
SYNC

SPEAKER
SHORT CIRCUIT
SECURITY CONTROL PANEL
SOUTH EAST
SECONDS
SERVICE ENTRANCE SUBSTATION
SMOKE/FUME EXHAUST PANEL
SWITCH OPERATOR
SLOW SPEED OL RELAY
SPARE
STAINLESS STEEL
STANDBY
SOURCE TRANSFER CONTROL
STANDARD
SUBSTATION
SUPPRESSOR
SURFACE
SWITCH
SOUTH WEST
STEEL WIRE ARMORED
SWITCHBOARD
SWITCHGEAR
SYMMETRICAL
SYNCHRONIZER

2S1W
2S2W
TSTAT
TB
TBD
TC
TDR
TS
TSP
TYP

TWO SPEED, ONE WINDING


TWO SPEED, TWO WINDING
THERMOSTAT
TERMINAL BLOCK
TO BE DETERMINED
TIME CLOCK
TIME DELAY RELAY
TAMPER SWITCH
TWISTED SHIELDED PAIR
TYPICAL

ROUTE
FAB
0=LVSS CUB
1=MCC
2=D.B
3=P.B
4=V.S.D

UPS

UNINTERRUPTIBLE POWER SUPPLY

LEVEL

V
VA
VESDA
VFD
VIB
VLF
VOB
VP
VS
VT

VOLTMETER, VOLT
VOLT-AMPERE
VERY EARLY SMOKE DETECTION
APPARATUS
VARIABLE FREQUENCY DRIVE
VERTICAL INSIDE BEND
VERTICAL LAMINAR FLOW UNIT
VERTICAL OUTSIDE BEND
VAPORPROOF
VOLTMETER SWITCH
VOLTAGE TRANSFORMER

VOLTAGE
H = 22KV
S = 6.6KV
P = <600V
D = <50V CONTROL CABLES

W
WHD
WP
WSPW
WW

WATT, WIRE
WATTHOUR DEMAND METER
WEATHERPROOF
WAFER STARTS PER WEEK
WIRE WAY

X
(X)
XFMR
XLPE

EXPLOSION PROOF - TYPE, CLASS


AND GROUP AS NOTED
REMOVE
TRANSFORMER
CROSS LINKED POLYETHELENE INSULATED

WYE-CONNECTED

Z
ZS

IMPEDANCE, ZONE
POSITION SWITCH

FLOOR: FAB/CUB
0 = UNDERGROUND
1 = UTILITIES
2 = SUBFAB
3 = CLEANROOM
4 = INTERSTITIAL/FAN-DECK
5 = UPPER FAN-DECK
6 = ROOF

MSB
0 = UNDERGROUND
1 = GROUND LEVEL
2 = SORT
3 = GOWN
4 = OFFICES
5 = OFFICES
6 = ROOF

BUILDING
B = BULK GAS YARD
C = CUB
F = FAB
H = HAZARDOUS MATERIALS BUILDING
M = MSCP
O = MSB
P = PROJECT BUILDING/WAREHOUSE
S = SITE/MAIN SUBSTATION
W = WAREHOUSE
IDENTIFIER
2 = FAB 28
2T = TEMPORARY POWER
3 = FAB 38

CONDUIT & CABLE NUMBERING SYSTEM


EG.: [AP-10100-03]
A P

XXX

-03
CIRCUIT/CUB #/00
SEQUENTIAL NUMBER

5=LVSS MSB
6=MCC
7=D.B
8=P.B
9=V.S.D

10=LVSS MLCP
11=MCC
12=D.B
13=P.B
14=V.S.D

15=LVSS
16=MCC
17=D.B
18=P.B
19=V.S.D

TYPE
BLANK = CONDUIT
A = ARMORED CABLE
U = UNARMORED CABLE
C = CONTROL

CABLE TRAY & TRUNKING ID SYSTEM

CONDUIT UP
EM
a

CONDUIT, STUBBED, AND CAPPED


C

TYPICAL LUMINAIRE ATTRIBUTES:


STAND ALONE LOWER CASE LETTER INDICATES SWITCH CONTROLLING
LAMP. NUMBER INDICATES CIRCUIT. LOWER CASE LETTER FOLLOWING
THE NUMBER INDICATES PHASE. UPPER CASE LETTER INDICATES
LUMINAIRE TYPE FROM LUMINAIRE SCHEDULE. HATCHING OR UPPER
CASE "EM" = EMERGENCY LUMINAIRE, "UPS" = UPS BACK-UP

A
10r

C = CONTROL SYSTEM CONDUIT

EM

EM = EMERGENCY POWER SYSTEM CONDUIT

FE-G = IRON REBAR GROUND LOOP CONDUCTOR

FE-G
U

CABLE TRAY
SIZE (mm)
F1 - E

BARE COPPER 120sqmm GROUND CONDUCTOR 80cm BELOW GRADE

E.G.:

UTILITY COMPANY SERVICE CONDUITS

GROUND ROD (EARTHING)

EXP

A
10r

SURFACE OR PENDANT MOUNTED LUMINAIRE

A
10r

WALL MOUNTED LUMINAIRE

ELEVATION (m)
(Bottom of tray)

- 00101

SEGMENT NUMBER
TRAY NUMBER

30

ROUTE
E = EAST
N = NORTH

LIGHTING FIXTURES EXPLOSION PROOF


S2

COPPER GROUND PLATE (ALSO FOR EQUIPMENT GROUNDING)

V= VERTICAL

RECESSED DOWN LIGHT


a 10r

GROUND TEST WELL


FGB/GP

EGB

A
10r

600mm X 1200mm FLUORESCENT LUMINAIRE

a
a

A
10r

300mm X 1200mm FLUORESCENT LUMINAIRE

FOUNDATION COPPER GROUNDING BUS / GROUNDING PLATE


ON COLUMN OR NEARBY
EQUIPOTENTIAL GROUNDING BUS

EXOTHERMIC WELD

A
10r

EMH

A
10r

KEYED INTERLOCK SWITCH

A
10r

A
10r

OR

?
#

CR

STRIP FLUORESCENT LUMINAIRE

ELECTRICAL MANHOLE

CONTROL RELAY OR MOTOR CONTACTOR COIL

MOTION DETECTOR; SUBSCRIPT DENOTES: U=ULTRASONIC P=PASSIVE


INFRARED

MD

A
#

EXIT LIGHT-CEILING OR WALL MOUNTED-DIRECTION ARROW AS


INDICATED. TYPE PER LUMINAIRE SCHEDULE. FACE OF SIGN
INDICATED BY SHADED SECTION
PHOTOELECTRIC LIGHTING CONTROL UNIT-SENSOR AIMED NORTH
UNLESS OTHERWISE NOTED

PC

NO CONNECTION
CONNECTION AS INDICATED

A
#

A
#

TRACK LIGHTING

HEAT TRACE LEGEND:

HEAT TRACE END-OF-LINE INDICATING LIGHT

HEAT TRACE POWER CONNECTION BOX, HEATING


CABLE TO POWER HOMERUN

MEDIUM VOLTAGE CABLE TERMINATION


2

0L

STARTER, SIZE INDICATED, W/OVERLOADS

100/M

400

630
400
400

30

HEAT TRACE CABLE SPICE BOX

S
xx

xx

ISSUED FOR MODELING

DE

08/21/14

ISSUED FOR MODELING

DE

06/26/14

REV. NO.

REVISION DESCRIPTION

APPROVED

CIRCUIT BREAKER; THERMAL MAGNETIC OR SOLID STATE TRIP. 3 POLE


UNLESS OTHERWISE INDICATED

HEAT TRACE THERMOSTAT WITH


BULB AND CAPILLARY

CIRCUIT BREAKER; THERMAL MAGNETIC OR SOLID STATE TRIP. 3 POLE


UNLESS OTHERWISE INDICATED, FIXED TYPE

HEAT TRACE RESISTANCE TEMPERATURE DEVICE

DATE

HENSEL PHELPS

HEAT TRACE HEATING CABLE (PLAN DRAWING ONLY)

FUSED SWITCH, SWITCH CURRENT RATING INDICATED,


3 POLE UNLESS OTHERWISE INDICATED
SWITCH CURRENT RATING INDICATED, 3 POLE UNLESS
OTHERWISE INDICATED

SELF REGULATING LOW TEMP HEAT TRACE CABLE, 208V


CABLE WATTAGE INDICATED AS:
3W = 3 WATT
5W = 5 WATT (AS SHOWN)
8W = 8 WATT
10W = 10 WATT

CIRCUIT BREAKER, SOLID STATE TRIP, PLUG-IN TYPE


630
400
400

FRAME RATING
BREAKER RATING
TRIP SETTING

80E
100

CIRCUIT BREAKER, MAGNETIC TRIP ONLY (MOTOR CIRCUIT


PROTECTOR). FRAME SIZE SHOWN, 3 POLE UNLESS OTHERWISE INDICATED

MSB
0 = UNDERGROUND
1 = GROUND LEVEL
2 = SORT
3 = GOWN
4 = OFFICES
5 = OFFICES

BUILDING
B = BULK GAS YARD
C = CUB
F = FAB
H = HAZARDOUS MATERIALS BUILDING
M = MSCP
O = MSB
P = PROJECT BUILDING/WAREHOUSE
S = SITE/MAIN SUBSTATION
W = WAREHOUSE

300mm X 600mm FLUORESCENT LUMINAIRE

10r

COPPER PIGTAIL

0 = UNDERGROUND
1 = UTILITIES
2 = SUBFAB
3 = CLEANROOM
4 = INTERSTITIAL/FAN-DECK
5 = UPPER FAN-DECK
6 = ROOF

600mm X 600mm FLUORESCENT LUMINAIRE

LIGHTNING PROTECTION AIR TERMINAL SPIKE

OR

WHEN MORE THAN (1) CABLE


TRAY TAG IS SHOWN AND
POINTED TO THE SAME TRAY,
IT INDICATES (2) OR MORE
STACKED TRAYS.

FRAME RATING
BREAKER RATING
TRIP SETTING

THIS DRAWING CONTAINS


INFORMATION WHICH IS THE

F28/F28A PROJECT ENGINEERING


Intel Israel
Lachish Campus
P.O. Box 82
Qiryat Gat 82109, Israel

INTEL CORPORATION.
SELF REGULATING MEDIUM TEMP HEAT TRACE CABLE, 208V
CABLE WATTAGE INDICATED AS:
3W = 3 WATT (AS SHOWN)
5W = 5 WATT
8W = 8 WATT
10W = 10 WATT
15W = 15 WATT
20W = 20 WATT

DATE

LC11 - ELECTRICAL
LEGEND, NOTES &
ABBREVIATIONS

DRAWN

CHECKED

CROSSCHECK

SAFETY

PLANNING

ENGINEER

APPROVED

EQT CODE

FWR NO.

FILE NAME

KBE-0005

OLD DWG NO.

PLOT SCALE

DRAWING NO.

KBE-0005

DRAWING SCALE

1=1

NAME: KBE-0005.DWG USER: Sparkman, Richard/PDX DATE: 10/9/2014 4:14 PM

NONE

SHEET

OF