Service Manual BML Myanmar PT.

Hartono Istana Teknologi

V. TRAP 34.4 Mc ADJUSTMENT


1. Set the circuit as following figure :

Vcc (+8V)
TUNER
IF 1K
IF AMP 5 EXT. AGC
IC 301
C 309
13
HBDC Modul
GERMANIUM
DIODE

1K
C 505

IN
SWEMAR
+14VDC
POWER
SUPLAY LBO

2. Set system on NTSC, and short Pin 4 of EA301 to ground.


3. Ensure setting is on (not standby).
4. Adjust Ext. AGC until the level of sinus signal is maximum without distortion.
5. Adjust Trap 34.4 Mc (Ldc-301) of HBDC modul to obtain minimum DIP (smallest signal level) or
until we get signal in the HBDC modul as following curve signal :

36.5Mc

38.9Mc

33.4Mc 41.4Mc
34.4Mc

Figure : IF curve of NTSC system

IF Measurement Standard for NTSC system :


Freq : 36.5MHz = 0dB (70dB)
38.9MHz = 6dB (5 - 7dB)
34.4MHz = 20dB (18-22dB)

note : HBDC modul no need to adjust if the circuit use SAW Filter MIF 389A ( Trap 34,4M on fixed Condi-
tion.

17