SafetyReliefValves
BesaS.p.A.Since1946MilanItaly

SampleProblemStatement
Clickhere
Designapressurereliefvalveforthefollowingservice.
andget
coolstuff!

Protectedequipment:Separatorvessel
Reliefservice:FuelGas
Reasonforrelief:Blockedgasdischarge
RelievingRate:10,000kg/hr
GasDensity:4.1kg/m3
Ratioofspecificheatsforthegas(CP/CV):1.55
Compressibilityfactorofgas=0.95
Molecularweightofgas=20gm/mole
Relievingtemperature=200C
Setpressure:4.5barg
Accumulation:10%
GoViral
Backpressureatreliefvalvedischarge:2.1barg
withUP
Typeofreliefvalve:BalancedBellows

Solution
Thissampleproblemforreliefvalvesizingcalculationcanbesolvedinfollowingsteps,whicharebased
onpressurereliefvalvesizingproceduresdescribedinAPIRP520PartI.Thefirststepistodetermine
whetherthegasflowtypeiscriticalorsubcritical.

Step1
Thefirststepistodetermineiftheflowconditionsarecriticalorsubcritical.Forthispurposethecritical
flowpressure(Pcf)downstreamtothereliefvalvehastobecalculatedusingthefollowingequationfrom
APIRP520PartI,

P1:Relievingpressureupstreamtoreliefvalveinbara
P1=5.96bara(including10%accumulation)
http://www.enggcyclopedia.com/2011/11/pressurereliefvalvesizingcalculationssubcriticalgasflow/

1/5

26/2/2015

PressureReliefValveSizingCalculationsSubcriticalGasFlowService|Enggcyclopedia

k:Ratioofspecificheatsofthegas..(CP/CV)
k=1.55

SegurodeBicicletas

Pcf:Criticalflowpressureforthegivenflow
conditionsinbara
Pcf=3.0bara
Ifthepressuredownstreamorbackpressure(3.113
bara)ofthereliefvalveisgreaterthanthecritical
flowpressure(3.0bara),thentheflowissaidtobe
ofsubcriticaltype.Inthepresentcase,back
pressure(3.113bara)>Pcf(3.0bara).Hencethe
flowisofsubcriticaltype.

Asegurahoratubiciy
beneficiate
CotizatubicicletaAhora.

Step2

Solicit+info

NextstepistousethereliefvalvesizingproceduregivenintheAPI520partIforsubcriticalflowtype
gasreliefvalve.Thefollowingequationisused,

...(1)
A:orificearerequirementinmm2
W:flowrateinkg/hr
W=10,000kg/hr
T:TemperatureinKelvin
T=273.16+20=293.26K
Z:compressibilityfactorofgas
Z=0.95
M:Molecularweightofthegas
M=20gm/mole
P1:Relievingpressureupstreamtoreliefvalveinbara
P1=5.96bara(including10%accumulation)
P2:backpressuredownstreamtoreliefvalveinbara
P2=3.11bara
Kd:Coefficientofdischarge
Kd=0.975forgasservice
KC:combinationcorrectionfactorforuseofrupturediscs
KC=1(forabsenceofrupturediscupstreamtothevalve)
http://www.enggcyclopedia.com/2011/11/pressurereliefvalvesizingcalculationssubcriticalgasflow/

2/5

26/2/2015

PressureReliefValveSizingCalculationsSubcriticalGasFlowService|Enggcyclopedia

F2:Coefficientofsubcriticalflow

k:Ratioofspecificheatsofthegas..(CP/CV)
k=1.55
r:ratioofbackpressuretorelievingpressure
r=P2/P1=0.58
hence,F2=0.5985
Pluggingthisdataintoequation(1),theminimumrequiredorificeareaforthereliefvalveiscalculatedto
be,
A=34.07cm2

Step3
Thenexthigheravailableorificeareashouldbeselectedforthepressurereliefvalvetobeactually
installed.ReferringtothetableofstandardorificesizesgiveninEnggCyclopedia'sreliefvalvesizing
calculator,nexthighavailableorificeareaisselectedtobeA=41.20cm2andthecorresponding
designatingletteris'P'.Availablevalvesizeis'4P6',whichcorrespondstodifferentnozzlesizesfor
suctionanddischargenozzlesofthepressurereliefvalve.Fora'4P6'valvesuctionnozzleisof4"size
anddischargenozzleof6"size.
VoteandShare!
0

Awesome

Inspiring

Love

Like

PoweredbyMyEffecto

NorelatedPages.
NorelatedPages.

Search
Searchfor: Search

Search

Signupnow
http://www.enggcyclopedia.com/2011/11/pressurereliefvalvesizingcalculationssubcriticalgasflow/

3/5

26/2/2015

PressureReliefValveSizingCalculationsSubcriticalGasFlowService|Enggcyclopedia

Signupforfreeifyouarenotamemberalready.

MemberLogin
Username:
Password:
forgotpassword?

RememberMe
LogMeIn

ListyourCompany
Listyourcompanyandproductswithusforfree.EnggCyclopediaisregularlyvisitedbythousands
ofindustryprofessionalsandbuyers.Getfreeexposurehere.Writetousat
admin@enggcyclopedia.com
Home
Piping
Miscellaneous
ProcessDesign
SolvedExamples
Newsletter
Calculators
UnitConversion
ContactUs

FreelancersWanted!!
Freelancerswantedtowriteforus.Shareyourexpertise,BroadenyourknowledgeandMonetize
yourskills.Writetousatadmin@enggcyclopedia.com

Categories
CodesandStandards
ElectricalEquipments
EngineeringQuestions
Instrumentation
Miscellaneous
Operation&Maintenance
Petroleumproducts
PhysicalProperties
Piping
ProcessDesign
Safety/LossPrevention
http://www.enggcyclopedia.com/2011/11/pressurereliefvalvesizingcalculationssubcriticalgasflow/

4/5

26/2/2015

PressureReliefValveSizingCalculationsSubcriticalGasFlowService|Enggcyclopedia

SolvedSampleProblems

PopularCalculators
InstrumentSizing
PSVsizingcalculatorfirecaseforliquidfilledvessel
Miscellaneous
Temperature

http://www.enggcyclopedia.com/2011/11/pressurereliefvalvesizingcalculationssubcriticalgasflow/

5/5

Вам также может понравиться