Вы находитесь на странице: 1из 2

File: 01-fc1417

Page 1 of 2

Fault Code 1417


Controller Power Down Fault
CODES
Fault Code: 1417
PID(P), SID(S):
FMI:
Lamp: Warning
SRT:

REASON

EFFECT

A controller power-down error has


been detected.

The ECM can not power down because of some


unknown condition. Possible drain on battery.

GCS ECM
Circuit Description:
The ECM checks during the power-down sequences to see if power is being shut off. If the power line is still hot, it checks
for a reason for not shutting down. If no reason exists, then there must be a problem with the module that is not allowing
it to power down.
Component Location:
Refer to the OEM manual for location of the ECM.
Shop Talk:
This fault indicates a hardware failure in the ECM.

Refer to Troubleshooting Fault Code t05-1417

2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A.


All Rights Reserved.

Printed from QuickServe Online.


Last Modified: 29-Jul-2010

File: 01-fc1417

2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A.


All Rights Reserved.

Page 2 of 2

Printed from QuickServe Online.


Last Modified: 29-Jul-2010