Fig. 8-1
Battery
Red cable (polarity +)
Latch
Fan
Danger
Do not attempt to reactivate discharged batteries with heat or by any other
means. The batteries must not be recharged because this could cause leakage
and/or explosion.
Non-compliance can cause injury to people or damage to property.
8-91
03.06
The NCU features battery-backed SRAMs and clock modules. The NCU monitors the backup voltage. The battery must be replaced within 6 weeks of a monitoring response. The battery/fan slide-in module in the NCU box can only be
changed after switching off the controller. The data is backed up for a period of
approx. 15 minutes.
Backup time
Replacement of
the battery/fan
slide-in module
The battery/fan subassembly is located under the DC link busbars (see Fig 3-3).
The slide-in module is replaced in its entirety.
Order number of the battery/fan slide-in unit:
6FC5247-0AA06-0AA0