Вы находитесь на странице: 1из 1

DX200D INSTALLATION AND PROGRAMMING

WIRING
120 VAC Neutral
120 VAC Hot

Wiring Connections
1
2
3
4
5

5 4 3 2 1
S1
S2

Motor Starter for Dryer


with unused NO Contacts built in

120VAC Hot
120VAC Neutral
Timer Start
No Connection
Timer Start

For timer to start counting, a dry contact closure


is required between terminals 3 and 5.
This closure may be either momentary or constant.
DO NOT APPLY VOLTAGE TO TERMINAL 3 OR 5

Other timer start connections


120 Volts Applied when Dryer starts

Dryer turn on signal Hot


Dryer turn on signal Neutral

120 Volt Hot


Coil
Common
NO Contacts

5 4 3 2 1

120 Volt Neutral

Jumper
3&5
5 4 3 2 1

Relay
DX 200 D
Timer will be dark when not in use.
When Dryer starts timer will light up and
start counting down.

DX 200 D
PROGRAMMING
Digits are individually set as follows:
S1 Adjusts seconds individually (right digit)
S2 Adjusts seconds by 10's (left digit)
Example: To set display to show 90 seconds: Set S2 to '9' Set S1 to'0'

DIXMOR ENTERPRISES
5755 S. GALLUP ST
LITTLETON CO 80120
303-794-0597