Вы находитесь на странице: 1из 6

Colour key

Field No Field Name

Updated/Added Fields

If no entry in this column data entry is Comment on the change

Supplementary Field

Selection

Remarks

1 General
2 PAGE
3 OF
4 JOB NUMBER
5 Equipment Number
6 Equipment service
7 Client
8 Project Title
9 Serial Number
10 REQ / SPEC NO.
11 PURCH ORDER NO.
12
13
14
15

16
17
18
19

DATE
BY
Checked
Approved
ISSUED FOR QUOTATION,
ISSUED FOR APPROVAL,
ISSUED FOR PURCHASE,
RE-ISSUED FOR QUOTATION,
RE-ISSUED FOR PURCHASE

Description
REVISION NO.
DATE:
DATASHEET NUMBER

Proposal,
Purchase,
As Built

20 APPLICABLE TO:

21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106

API-610,
ASME B73.1,
ASME B73.2,
PIP RESP73H-97,
PIP RESP73V-97,
ISO, OTHER
Free field

APPLICABLE NTL/INTNTL STANDARD:

SPECIFY
FOR
UNIT
SITE
SERVICE
NO. REQ
PUMP SIZE
TYPE
NO. STAGES
MANUFACTURER
MODEL
SERIAL NO.
Datasheets
PUMP

How do we handle 6 or 12 items?


ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED

MOTOR
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
GEAR
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
TURBINE
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
APPLICABLE OVERLAY STANDARD(S):
REVISIONS
NO.
DATE
BY
NO.
DATE
BY
NO.
DATE
BY
NO.
DATE
BY
NO.
DATE
BY
NO.
DATE
BY
OPERATING CONDITIONS (6.1.2)
Flow

SUCTION PRESS.

DISCHARGE PRESSURE (6.3.2)

DIFFERENTIAL PRESSURE

DIFF. HEAD

Applicable pump specs only

NORMAL
RATED
Max.
Min.
NORMAL
RATED
Max.
Min.
NORMAL
RATED
Max.
Min.
NORMAL
RATED
Max.
Min.
NORMAL
RATED
Max.
Min.

NPSHA
C.L. Impeller,
Top of Foundation

107 NPSHA Datum:


108 CL pump to U/S baseplate
109 HYDRAULIC POWER

CONTINUOUS,
INTERMITTENT

110 SERVICE
111 IF INTERMITTENT (STARTS/DAY)
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134

PUMPS OPERATE IN:


LIQUID
LIQUID TYPE OR NAME
PUMPING TEMP

VAPOR PRESS.
RELATIVE DENSITY :
SPECIFIC HEAT
VISCOSITY (cP)

PARALLEL,
SERIES

MIN
RATED
NORMAL
MAX.
MIN
MAX.
MIN
MAX.
MIN
MAX.
MIN
MAX.

CHLORIDE CONCENTRATION
H2S CONCENTRATION (6.12.1.1)
CORROSION DUE TO (6.12.1.9)
EROSION DUE TO : (6.12.1.9)
PARTICULATE SIZE (DIA IN MICRONS)
PARTICULATE CONCENTRATION (PPM)
SITE DATA

2 lines required

LOCATION: (5.1.30)

135

INDOOR,
OUTDOOR

136

HEATED,
UNHEATED

137

UNDER ROOF,
PARTIAL SIDES
MEZZANINE,
GRADE

138 MOUNTED AT :
139 ELECTRICAL AREA CLASSIFICATION (6.1.22)

140

141

If other in line above then specifiy applicable spec.

CL(EIC)

T1,
T2,
T3,
T4,
T5,
T6

CL(NEMA)

T1,
T2,
T2A,
T2B,
T2C,
T2D,
T3,
T3A,
T3B,
T3C,
T4,
T4A,
T5,
T6

142

143
144
145
146
147
148
149
150
151
152
153

154
155
156
157
158
159

GR (EIC)

GR (NEMA)
Haz Area Name
WINTERIZATION REQ'D
TROPICALIZATION REQ'D.
SITE DATA (5.1.30)
ELEVATION
BAROMETER
RANGE OF AMBIENT TEMPS:

DUST
FUMES
OTHER

UNUSUAL CONDITIONS: (5.1.30)


SPECIFY OTHER
MATERIALS (6.12.1.1)
ANNEX H CLASS
MIN DESIGN METAL TEMP (6.12.4.1)
REDUCED-HARDNESS MATERIALS REQ'D (6.12.1.12.1)

Applicable Hardness Standard (6.12.1.12.3)


BARREL :
CASE
IMPELLER
IMPELLER WEAR RING
CASE WEAR RING
DIFFUSERS
SHAFT
Bowl (if VS-type)

169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199

Inspection Class
PERFORMANCE:
PROPOSAL CURVE NO.
As Tested Curve No.
RPM
IMPELLER DIA.

Class I Group A,
Class I Group B,
Class I Group C,
Class I Group D,
Mining, Class II Group E,
Class II Group F,
Class II Group G,
Class III
DIV, Zone
YES, NO
YES, NO

MIN
MAX
MIN
MAX

RELATIVE HUMIDITY:

160
161
162
163
164
165
166
167
168

Group IIC,
Group IIB + H2,
Group IIB,
Group IIA,
Group I

Yes, No

Level 1,
Level 2,
Level 3

RATED
MAX.
MIN.

RATED POWER
EFFICIENCY
RATED CURVE BEP FLOW (at rated impeller dia)
MINIMUM CONTINUOUS FLOW:

THERMAL
STABLE
FROM
TO
FROM
TO

PREFERRED OPER. REGION (6.1.12)


ALLOWABLE OPER. REGION
MAX HEAD @ RATED IMPELLER
MAX POWER @ RATED IMPELLER (6.8.9)
NPSHR AT RATED Flow (5.1.10)
CL pump to U/S baseplate
NPSH Margin at Rated Flow
SPECIFIC SPEED (6.1.9)
SUCTION SPECIFIC SPEED LIMIT
SUCTION SPECIFIC SPEED
MAX. SOUND PRESS. LEVEL REQ'D (6.1.14)
EST MAX SOUND PRESS. LEVEL
MAX. SOUND POWER LEVEL REQ'D (6.1.14)
EST MAX SOUND POWER LEVEL
DRIVER (7.1.5)

MOTOR,
STEAM TURBINE
YES, NO
YES, NO

200 Driver Type


201 GEAR
202 VARIABLE SPEED REQUIRED

203
204
205
206
207
208
209
210
211
212
213
214

SOURCE OF VARIABLE SPEED


OTHER
MANUFACTURER
NAMEPLATE POWER
Nominal RPM
RATED LOAD RPM
FRAME OR MODEL
ORIENTATION
LUBE
BEARING TYPE
RADIAL
THRUST

215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252

Starting Method
See driver datasheet

Motor,
Gear Coupling,
Other

HORIZONTAL, VERTICAL

Open Valve (Fully-Loaded),


Closed-Valve (Unloaded) Start

UTILITY CONDITIONS
ELECTRICITY
DRIVERS VOLTAGE
PHASE
HERTZ
HEATING VOLTAGE
PHASE
HERTZ
CONTROL VOLTAGE
PHASE
HERTZ
SHUTDOWN VOLTAGE
PHASE
HERTZ
STEAM
DRIVERS MAX. PRESS.
MAX. TEMP.
MIN. PRESS.
MIN. TEMP.
HEATING MAX. PRESS.
MAX. TEMP.
MIN. PRESS.
MIN. TEMP.
COOLING WATER (5.1.19)
SOURCE
TEMP

INLET
RETURN MAX
DESIGN
INLET
RETURN MIN
DESIGN

PRESS

COOLING WATER CHLORIDE CONCENTRATION:


INSTRUMENT AIR PRESSURE

MAX
MIN

CONSTRUCTION
ROTATION:

CW, CCW

253 PUMP TYPE: (4.1)

OH1,OH2,OH3,OH4,OH5,OH6,
BB1,BB2,BB3,BB4,BB5,
VS1,VS2,VS3,VS4,VS5,VS6,VS7

254 CASING MOUNTING:

CENTERLINE,
FOOT,
IN-LINE,
NEAR CENTERLINE,
VERTICAL,
SUMP COVER PLATE,
SEPARATE MOUNTING PLATE,
SEPARATE SOLE PLATE

255
256
257
258
259
260
261
262
263
264
265
266
267
268

See lines 159 & 160

NA, ISO 15156,


MR0103,
MR0175

SINGLE VOLUTE,
MULTIPLE VOLUTE,
DIFFUSER
YES, NO

CASING TYPE: (6.3.10)


OH3 BACK-PULLOUT LIFTING DEVICE REQD.
CASE PRESSURE RATING:
PUMP SUCTION REGION DESIGNED FOR MAWP (6.3.6)
MAWP (6.3.6)

YES, NO
at temperature

HYDROTEST PRESSURE
HYDROTEST OH PUMP AS ASSEMBLY (7.3.2)

YES, NO
YES, NO, BOTH DIR
YES, NO
YES, NO

IMPELLERS INDIVIDUALLY SECURED :


BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION :
PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS

NOZZLE CONNECTIONS: (6.5.5)


SUCTION

269
270
271
272 DISCHARGE

273
274
275
276 PRESSURE CASING AUX. CONNECTIONS: (6.4.3.2)

SIZE

FLANGE RATING
FAC'G
POSITION
SIZE

FLANGE RATING
FAC'G
POSITION

125,
150,
250,
300,
600,
900,
1500,
2500
FF, RF, RTJ

125,
150,
250,
300,
600,
900,
1500,
2500
FF, RF, RTJ

Casing split removed based on the use to these


designations

These inputs removed


OVERHUNG, BETWEEN BEARINGS, BARREL

277 DRAIN
278
279
280

281
282
283
284
285
286
287
288 VENT
289
290
291

292
293
294
295
296
297 PRESSURE GAUGE
298
299
300

NO.
SIZE
TYPE
FAC'G

RATING
POSITION
Drain Valve Supplied By
VS6 Drain
DRAIN TO SKID EDGE
DRAINS MANIFOLDED

RATING
POSITION
VENT Valve Supplied By
VENTS MANIFOLDED

307
308
309 WARM-UP LINE
310
311
312

313
314
315 BALANCE / LEAK OFF
316
317
318

319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342

SW, SWF
FF, RF, RTJ
125,
150,
250,
300,
600,
900,
1500,
2500
Pump Mnfg, Purchaser, None
YES, NO

NO.
SIZE
TYPE
FAC'G

RATING
POSITION
NO.
SIZE
TYPE
FAC'G

RATING
POSITION
NO.
SIZE
TYPE
FAC'G

RATING
POSITION
NO.
SIZE
TYPE
FAC'G

RATING
POSITION
THREADED CONNECTIONS FOR PIPELINE SERVICE & < 50C (6.4.3.2)
SPECIAL FITTINGS FOR TRANSITIONING (6.4.3.3)
CYLINDRICAL THREADS REQUIRED (6.4.3.8)
GUSSET SUPPORT REQUIRED
MACHINED AND STUDDED CONNECTIONS (6.4.3.12)

SW, SWF
FF, RF, RTJ
125,
150,
250,
300,
600,
900,
1500,
2500

SW, SWF
FF, RF, RTJ
125,
150,
250,
300,
600,
900,
1500,
2500

SW, SWF
FF, RF, RTJ
125,
150,
250,
300,
600,
900,
1500,
2500

SW, SWF
FF, RF, RTJ
125,
150,
250,
300,
600,
900,
1500,
2500
YES, NO
YES, NO
YES, NO

ROTOR:
SHAFT FLEXIBILITY INDEX (SFI) (9.1.1.3)
First Critical Speed Wet (Multi stage pumps only)
COMPONENT BALANCE TO ISO 1940-1 G1.0
SHRINK-FIT-LIMITED MOVEMENT IMPELLERS (9.2.2.3)

YES, NO
YES, NO

COUPLING:(7.2.3) (7.2.13.f)
MANUFACTURER
MODEL
RATING (POWER/100 RPM)
SPACER LENGTH
SERVICE FACTOR
RIGID
COUPLING WITH HYDRAULIC FIT (7.2.10)
COUPLING BALANCED TO ISO 1940-1 G6.3 (7.2.3)
COUPLING WITH PROPRIETARY CLAMPING DEVICE (7.2.11)

1, 1.5, 2
YES, NO
YES, NO
YES, NO
ISO 14691,
ISO 10441,
API 671,
API 610 compliant, mfr std

343 COUPLING IN COMPLIANCE WITH (7.2.4)

344
345
346
347
348

125,
150,
250,
300,
600,
900,
1500,
2500
Pump Mnfg, Purchaser, None
Internal, External, N/A
YES, NO
YES, NO

NO.
SIZE
TYPE
FAC'G

301
302
303 TEMPERATURE GAUGE
304
305
306

SW, SWF
FF, RF, RTJ

ISO 14120,
EN 953,
ANSI/AMT B15.1
Yes, No

COUPLING GUARD STANDARD PER (7.2.13 a)


Window on Coupling Guard
BASEPLATE:
API BASEPLATE NUMBER

349 BASEPLATE CONSTRUCTION (7.3.14)

OPEN BEAM SUPPORT,


FULL TOP DECKING,
PARTIAL TOP DECKING,
OPEN DECKING

350
351
352
353

MOUNTING :
NON-GROUT CONSTRUCTION (7.3.13)
VERTICAL LEVELING SCREWS :
LONGITUDINAL DRIVER POSITIONING SCREWS :

GROUTED,
BOLTED ON STEEL WORK,
THREE POINT MOUNT,
FOUR POINT MOUNT,
STILT MOUNTED
YES, NO
REQUIRED, NOT REQUIRED
REQUIRED, NOT REQUIRED

354
355
356
357
358
359
360
361
362

Baseplate Drainage (7.3.1)


SUPPLIED WITH :

363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385

Identify Location on Baseplate


INTERCONNECTING PIPING BY
MECHANICAL SEAL (6.8.1)
SEE ATTACHED ISO 21049/API 682 DATA SHEET
ADDITIONAL CENTRAL FLUSH PORT (6.8.9)
HEATING JACKET REQ'D. (6.8.11)

386
387
388
389
390

SHIPMENT: (8.4.1)
EXPORT BOXING REQUIRED
OUTDOOR STORAGE MORE THAN 6 MONTHS

391
392
393
394
395
396
397
398
399

ROTOR STORAGE ORIENTATION (9.2.8.2)


SHIPPING & STORAGE CONTAINER FOR VERT STORAGE (9.2.8.3)
N2 PURGE (9.2.8.4)

GROUT AND VENT HOLES


DRAIN CONNECTION

MOUNTING PADS SIZED FOR BASEPLATE LEVELING (7.3.5)


MOUNTING PADS TO BE MACHINED (7.3.6)
PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET
OTHER
SEAL SUPPORT SYSTEM MOUNTING
Seal Support System mounted on pump baseplate (7.5.1.4)

Entire Baseplate Drain Rim,


Entire Baseplate Drain Pan,
Partial Drain Pan
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
Partial Top Plate Pre Grouted?
Yes, No, N/A
PURCHASER, SUPPLIER

YES, NO
YES, NO

SURFACE PREPARATION AND PAINT


MANUFACTURER'S STANDARD
OTHER (SEE BELOW)
SPECIFICATION NO.
PUMP:
PUMP SURFACE PREPARATION
PRIMER
FINISH COAT
BASEPLATE: (6.3.17)
BASEPLATE SURFACE PREPARATION
PRIMER:
FINISH COAT
DETAILS OF LIFTING DEVICES (6.3.20)
DOMESTIC,
EXPORT
YES, NO
YES, NO

SPARE ROTOR ASSEMBLY PACKAGED FOR:


HORIZONTAL,
VERTICAL
YES, NO
YES, NO

HEATING AND COOLING (6.1.17)


COOLING REQ'D
COOLING WATER PIPING PLAN (6.5.3.1)
COOLING WATER PIPING

400 COOLING WATER PIPING MATERIALS

YES, NO
PIPE, TUBE
FITTINGS
CS,
GALVANIZED,
STAINLESS STEEL

401
402
403
404
405
406
407

COOLING WATER REQUIREMENTS:

BEARING HOUSING
HEAT EXCHANGER

TOTAL COOLING WATER


HEATING MEDIUM
HEATING PIPING

STEAM, OTHER
PIPE, TUBE

BEARINGS AND LUBRICATION (6.10.1.1)

408 BEARING RADIAL (6.11.4)


409

TYPE
NUMBER

410 BEARING THRUST


411
412 REVIEW AND APPROVE THRUST BEARING SIZE : (9.2.5.2.4)

TYPE
NUMBER

BALL,
ROLLER,
SLEEVE,
TILT PAD

GREASE,
FLOOD,
RING OIL,
FLINGER,
PRESSURE LUBE,
PURGE OIL MIST,
PURE OIL MIST
2,3
YES, NO
YES, NO
Yes, No, N/A

413 LUBRICATION: (6.10.2.2) (6.11.3) (9.6.1)


414 PRESSURE LUBE TO ISO 1043(9.2.6.5)
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442

BALL,
ROLLER,
SLEEVE,
TILT PAD

ISO 10438-2 DATASHEETS ATTACHED


Pressurized Lube Oil System mounted on same baseplate as pump
Location of Pressurized Lube Oil System mounted on baseplate
INTERCONNECTING PIPING PROVIDED BY
CONSTANT LEVEL OILER PREFERENCE(5.10.2.2)
OIL VISC. ISO GRADE VG
OIL PRESS. TO BE GREATER THAN COOLANT PRESSURE
REVIEW AND APPROVE THRUST BEARING SIZE(8.2.5.2.4)
OIL HEATER REQUIRED:

Purchaser, Supplier

STEAM, ELECTRIC

INSTRUMENTATION
SEE ATTACHED API-670 DATASHEET
ACCELEROMETER (7.4.2.1)

YES, NO
Number of Accelerometers
Mounting Location of Accelerometers

PROVISION FOR MTG ONLY (6.10.2.10)

YES, NO
Number of Accelerometers
Mounting Location of Accelerometers

FLAT SURFACE REQUIRED (6.10.2.11)

YES, NO
Number of Accelerometers
Mounting Location of Accelerometers

PROVISIONS FOR VIB. PROBES (7.4.2.2)

YES, NO
NUMBER PER RADIAL BEARING
NUMBER PER AXIAL BEARING

PROVISION FOR MTG ONLY


MONITORS AND CABLES SUPPLIED BY (7.4.2.4)
TEMPERATURE (7.4.2.3)
PROVISIONS FOR TEMP PROBES

YES, NO

YES, NO

443 RADIAL BEARING TEMP.


444 NUMBER PER RADIAL BEARING
445 THRUST BEARING TEMP.

YES, NO

446 NUMBER PER THRUST BEARING ACTIVE SIDE


447 NUMBER PER THRUST BEARING INACTIVE SIDE
448 TEMP. GAUGES (WITH THERMOWELLS) (9.1.3.6)
449 PRESSURE GAUGE TYPE
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495

Remarks
PIPING & APPURTENANCES
MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)

VENT
DRAIN
COOLING WATER

TAG ALL ORIFICES (7.5.2.4)


SOCKET WELD CONN ON SEAL GLAND (7.5.2.8)

YES, NO
YES, NO
YES, NO
YES, NO
YES, NO

Weight
ITEM NO
PUMP
BASE
DRIVER
GEAR
TOTAL
ITEM NO
PUMP
BASE
DRIVER
GEAR
TOTAL
ITEM NO
PUMP
BASE
DRIVER
GEAR
TOTAL
SPARE PARTS
START-UP
NORMAL MAINTENANCE
OTHER PURCHASER REQUIREMENTS
COORDINATION MEETING REQUIRED (10.1.3)
MAXIMUM DISCHARGE PRESSURE TO INCLUDE (5.12.3.4)

CONNECTION DESIGN APPROVAL (9.2.1.4)


TORSIONAL ANALYSIS / REPORT (6.9.2.10)
PROGRESS REPORTS (9.3.3)
OUTLINE OF PROCEDURES FOR OPTIONAL TESTS (10.2.5)
ADDITIONAL DATA REQUIRING 20 YEARS RETENTION (8.2.1.1)
LATERAL ANALYSIS REQUIRED (9.1.3.4) (9.2.4.1.3)
MODAL ANALYSIS REQUIRED (9.3.5)
DYNAMIC BALANCE ROTOR (6.9.4.4)
INSTALLATION LIST IN PROPOSAL (10.2.3 l)
VFD STEADY STATE DAMPED RESPONSE ANALYSIS (6.9.2.3)

YES, NO
YES, NO

MAX RELATIVE DENSITY


YES, NO
MAX DIA. IMPELLERS AND/OR NO OF S YES, NO
OPERATION TO TRIP SPEED
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO

496 TRANSIENT TORSIONAL RESPONSE (6.9.2.4)

YES, NO

497 BEARING LIFE CALCULATIONS REQUIRED (6.10.1.6)

YES, NO

498 IGNITION HAZARD ASSESMENT TO EN 13463-1 (7.2.14)

YES, NO

499 CASING RETIREMENT THICKNESS DRAWING (10.3.2.3)

YES, NO

500 FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS (7.5.2.8)


501 INCLUDE PLOTTED VIBRATION SPECTRA (6.9.3.3)

502 CONNECTION BOLTING (7.5.1.7)

PTFE COATED,
ASTM 153 GALVANISED,
PAINTED, SS

503 CADMIUM PLATED BOLTS PROHIBITED

YES, NO

504 VENDOR TO KEEP REPAIR AND HT RECORDS (8.2.1.1.c)


505 VENDOR SUBMIT TEST PROCEDURES (8.3.1.1)
506 SUBMIT INSPECTION CHECK LIST (8.1.5)
507 VERTICAL PUMPS
508 PUMP THRUST:
509 STATIC THRUST

UP

510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525

DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN

AT MIN. FLOW
AT RATED FLOW
AT MAX. FLOW
MAX THRUST
THRUST BRG RATING:
SOLEPLATE REQD

YES, NO
LENGTH
WIDTH
THICKNESS

MOUNTING FLANGE REQUIRED

YES, NO
FLANGED,
THREADED

526 COLUMN PIPE


527
528
529
530
531 GUIDE BUSHING
532

DIAMETER
LENGTH
NUMBER
SPACING
NUMBER
LINE SHAFT BEARING SPACING

533

LUBE

534
535
536
537
538

OPEN,
CLOSED

LINESHAFT
LINESHAFT DIAMETER
LINE SHAFT BEARING SPACING
TUBE DIAMETER
LINESHAFT COUPLING

SLEEVE & KEY,


THREADED

539 LINESHAFT CONNECTION


540 SUCTION STRAINER TYPE
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559

LEVEL CONTROL
IMPELLER COLLETS ACCEPTABLE
HARDENED SLEEVES UNDER BEARINGS (9.3.10.5)
RESONANCE TEST
STRUCTURAL ANALYSIS (9.3.5)
DRAIN PIPED TO SURFACE
DRIVER ALIGNMENT SCREWS
SUCTION CAN

WATER, OIL,
GREASE,
PUMPAGE

FLOAT SWITCH,
LEVEL TRANSMITTER
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
THICKNESS
LENGTH
DIAMETER
DRAIN PIPED TO SURFACE (9.3.13.5)

SEPARTATE MOUNTING PLATE (9.3.8.3.1)


PROVIDE SEPARATE SOLEPLATE (9.3.8.3.3)
BOWL HEAD CALCULATION REQUIRED

YES, NO
YES, NO
YES, NO

MATERIALS (additional)
SUCTION CAN / BARREL:
DISCHARGE HEAD
BOWL SHAFT :

FABRICATED, CAST

560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609

LINESHAFT :
LINESHAFT HARDFACING :
BELLMOUTH :
BOWL BEARING :
LINESHAFT BEARING :

LINESHAFT SLEEVES :
BEARING RETAINER :

PRESSURE RATING:

SHAFT ENCLOSING TUBE :


DISCHARGE COLUMN
HEAD
MAWP
HYDRO
COLUMN PIPE MAWP
HYDRO
BOWL MAWP
HYDRO

SUMP DIMENSIONS
GRADE ELEVATION
LOW LIQUID LEVEL
C.L. OF DISCHARGE
SUMP DEPTH
PUMP LENGTH
GRADE TO DISCH.
GRADE TO LOW LIQUID LVL
GRADE TO 1ST STG IMPL'R.
SUBMERGENCE REQ'D
SUMP DIAMETER
TEST
SHOP INSPECTION (8.1.1)
PERFORMANCE CURVE & DATA APPROVAL PRIOR TO SHIPMENT.
TEST WITH SUBSTITUTE SEAL (8.3.3.2)
MATERIAL CERTIFICATION REQUIRED (6.12.1.8)

CASTING REPAIR WELD PROCEDURE APPROVAL REQUIRED (6.12.2.5) (6.12.3.1)


INSPECTION REQUIRED FOR CONNECTION WELDS (6.12.3.4.d) (6.12.3.4.e)

INSPECTION REQUIRED FOR CASTINGS

1
2
3
l1
l2
l3
l4
l5
l6
d
YES, NO
YES, NO
CASING
IMPELLER
SHAFT
OTHER
MAG PARTICLE
RADIOGRAPHY
LIQUID PENETRANT
ULTRASONIC
MAG PARTICLE
RADIOGRAPHY
LIQUID PENETRANT
ULTRASONIC

HARDNESS TEST REQUIRED (8.2.2.7)


ADDITIONAL SUBSURFACE EXAMINATION (6.12.1.5) (8.2.1.3)

YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO

FOR
METHOD
PMI TESTING REQUIRED (8.2.2.8)
COMPONENTS TO BE TESTED
RESIDUAL UNBALANCE TEST (J.4.1.2)

YES, NO
YES, NO

610 NOTIFICATION OF SUSSESSFUL SHOP PERFORMANCE TEST (8.1.1.c) (8.3.3.5)

YES, NO

611

NON-WIT,
WIT,
OBSERVE

612 HYDROSTATIC

NON-WIT,
WIT,
OBSERVE

613 HYDROSTATIC TEST OF BOWLS & COLUMN (9.3.13.2)

NON-WIT,
WIT,
OBSERVE

614 PERFORMANCE TEST

NON-WIT,
WIT,
OBSERVE

615 TEST IN COMPLIANCE WITH (8.3.3.2)

8.3.3.2
MANUFACTURERS STANDARD

616 TEST DATA POINTS TO (8.3.3.3)

8.3.3.3
MANUFACTURERS STANDARD

617 TEST TOLERANCES TO (8.3.3.4)

TABLE 16
AGREED LIMITS

618 NPSH (8.3.4.3.1) (8.3.4.3.4)

NON-WIT,
WIT,
OBSERVE

619 NPSH-1ST STG ONLY (8.3.4.3.2)

NON-WIT,
WIT,
OBSERVE

620 NPSH TESTING TO HI 1.6 OR ISO 9906 (8.3.4.3.3)


621 TEST NPSHA LIMITED TO 110% SITE NPSHA (8.3.3.6)

NON-WIT,
WIT,
OBSERVE
YES, NO

622 RETEST ON SEAL LEAKAGE (8.3.3.2 d)

NON-WIT,
WIT,
OBSERVE

623 RETEST REQUIRED AFTER FINAL HEAD ADJUSTMENT (8.3.3.7 b)

NON-WIT,
WIT,
OBSERVE

624 COMPLETE UNIT TEST (8.3.4.4.1)

NON-WIT,
WIT,
OBSERVE

625 SOUND LEVEL TEST (8.3.4.5)

NON-WIT,
WIT,
OBSERVE

626 CLEANLINESS PRIOR TO FINAL ASSEMBLY (8.2.2.6)

NON-WIT,
WIT,
OBSERVE

627 LOCATION OF CLEANLINESS INSPECTION

@ SUPPLIER'S
@ SUB-SUPPLIER'S

628 NOZZLE LOAD TEST

NON-WIT,
WIT,
OBSERVE

629 CHECK FOR CO-PLANAR MOUNTING PAD SURFACES

NON-WIT,
WIT,
OBSERVE

630 MECHANICAL RUN TEST UNTIL OIL TEMP STABLE (8.3.4.2.1)

NON-WIT,
WIT,
OBSERVE

631 4 HR. MECH RUN AFTER OIL TEMP STABLE(8.3.4.2.2)

NON-WIT,
WIT,
OBSERVE

632 4 HR. MECH RUN TEST (8.3.4.2.2)

NON-WIT,
WIT,
OBSERVE

633 TRUE PEAK VELOCITY DATA

NON-WIT,
WIT,
OBSERVE

634 BRG HSG RESONANCE TEST (8.3.4.7)

NON-WIT,
WIT,
OBSERVE

635 STRUCTURAL RESONANCE TEST (9.3.9.2)

NON-WIT,
WIT,
OBSERVE

636 REMOVE / INSPECT HYDRODYNAMIC BEARINGS AFTER TEST ( 9.2.7.5)

NON-WIT,
WIT,
OBSERVE

BASEPLATE TEST (7.3.21)

8.3.4.7, 9.3.9.2

NON-WIT,
WIT,
OBSERVE

637 AUXILIARY EQUIPMENT TEST PER (8.3.4.6)


638 LOCATION OF AUXILIARY EQUIPMENT TEST
639 EQUIPMENT TO BE INCLUDED IN AUXILLIARY TESTS
PER EN 13445
640 IMPACT TEST (6.12.4.3)
PER ASME SECTION VIII
641
642
643
644
645
646
647
648

REMOVE CASING AFTER TEST


VENDOR TO KEEP REPAIR AND HT RECORDS (7.2.1.1C)
VENDOR SUBMIT TEST PROCEDURES (7.3.1.2 / 9.2.5)
VENDOR SUBMIT TEST DATA WITHIN 24 HOURS (7.3.3.3E)
INCLUDE PLOTTED VIBRATION SPECTRA (5.9.3.3)
SUBMIT INSPECTION CHECK LIST (7.1.6)
PRESSURE VESSEL DESIGN CODE REFERENCES

THESE REFERENCES MUST BE LISTED BY THE


649 MANUFACTURER
650
651
652 WELDING AND REPAIRS

SOURCE OF MATERIAL
PROPERTIES (6.3.4)

YES, NO
PURCHASER DEFINED,
DEFAULT PER TABLE 14

Welding Requirement (Applicable Code or Standard)


WELDER/OPERATOR QUALIFICATION
WELDING PROCEDURE QUALIFICATION
NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
MAGNETIC PARTICLE OR LIQUID PENETRANT EXAMINATION OF PLATE EDGES
POSTWELD HEAT TREATMENT
POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS

MATERIAL INSPECTION

THESE REFERENCES MUST BE LISTED BY THE


664 PURCHASER DEFAULT TO TABLE 14
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682

NON-WIT,
WIT,
OBSERVE
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO
YES, NO

CASTING FACTORS USED IN


DESIGN( 6.3.4)( TABLE 4)

THESE REFERENCES MUST BE LISTED BY THE


653 PURCHASER. (DEFAULT TO TABLE 11 IF NO PURCHASER PREFERENCE IS STATED)
654 ALTERNATIVE WELDING CODES AND STANDARDS (5.12.3.1)
655
656
657
658
659
660
661
662
663

NON-WIT,
WIT,
OBSERVE

ALTERNATIVE MATERIAL INSPECTIONS AND


ACCEPTANCE CRITERIA (SEE TABLE 15) (8.2.2.5)
RADIOGRAPHY

ULTRASONIC INSPECTION

MAGNETIC PARTICLE INSPECTION

LIQUID PENETRANT INSPECTION

VISUAL INSPECTION (all surfaces)

Comments Page 1
REMARKS PAGE 3

YES, NO

METHOD
FOR FABRICATIONS
FOR CASTINGS
METHOD
FOR FABRICATIONS
FOR CASTINGS
METHOD
FOR FABRICATIONS
FOR CASTINGS
METHOD
FOR FABRICATIONS
FOR CASTINGS
METHOD
FOR FABRICATIONS
FOR CASTINGS
Free field 60 characters 10 rows
Free field 60 characters 6 rows

683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699

REMARKS PAGE 4
REMARKS PAGE 7
Notes Page
Note reference page 2
Note reference page 3
Note reference page 4
Note reference page 5
Note reference page 6
Note reference page 7
Note reference Notes Page

Line Numbers
Note Numbers
Line Numbers
Note Numbers
Line Numbers
Note Numbers
Line Numbers
Note Numbers
Line Numbers
Note Numbers
Line Numbers
Note Numbers
Line Numbers
Note Numbers

Free field 60 characters 33 rows


Free field 90 characters 36 rows
Free field 90 characters 57 rows
List line number where note reference exists
List note number
List line number where note reference exists
List note number
List line number where note reference exists
List note number
List line number where note reference exists
List note number
List line number where note reference exists
List note number
List line number where note reference exists
List note number
List line number where note reference exists
List note number

Вам также может понравиться