Вы находитесь на странице: 1из 1

Rancangan Power Aerator Dengan faktor BOD Loading

Volume bak aerasi = 1.200 M3


BOD loading = ( 0.3 05 )Kg BOD/m3day
Untuk mencapai BOD loading 0.5 Kg BOD/ m3day
Maka seharusnya :
Volume bak =1200 M3
COD in = 3000 ppm
Debit = 400 m3/day
BOD loading = ( BOD x Q ) / V
= 1500 x 400 / 1200
= 0.5 Kg BOD/ m3day
MLSS direncanakan 4500 ppm
F/M = ( BOD x Q ) / MLVSS x V
= ( 1500 x 400 ) / ( 3375 x 1200 )
= 0.148
q = Oksigen transfer rate dari surface aerator ( lihat dispek alat ) bila tidak ada maka diasumsikan
sebesar 2.5 3.5 lb O2/HP.hr
Q = 400 M3/hari = 0.1057 mgd ( 1mgd = 3785 M3/hari )
L = BOD in = 1500 ppm
d = densitas air limbah = 8.34 Lb/ Galon
P = ( Q x d x L ) / 24 x q
= ( 0.1057 x 8.34 x 1500 ) / 24 x 2.5
= 22 HP
= 16.53 Kw + 50%(untuk keamanan )
= 16.53 + 8.26
= 24.75 KW
= 25 KW
Suplai udara ( kalau bentuknya Blower )
Suplai udara = ( 45 90 ) m3 / Kg BOD
Suplai udara = Suplai udara x BOD load x V
= 60 m3 / Kg BOD x 0.5 Kg BOD/ m3day x 1200 m3
= 36000 m3/day