Вы находитесь на странице: 1из 1

Configurable mains input

terminal blocks

SPD

0V

DC Earth (TE)

..

CU-bar common +48V -24V

3ph 400Vac
LVBD
com

System Connection Board


200625
*X5 TB1

Battery Current

L1 L2 L3

L1

JP3
2

PE CON12
L1 CON11
L2 CON10
PE CON15
L1 CON14
L2 CON13
PE CON18
L1 CON17
L2 CON16
PE CON21
L1 CON20
L2 CON19

JP2

Battery Fuse Fail


Load Fuse Fail 1
LVD 1A
LVD Common
LVD 2A
LVD Common

Alarm Outputs and


Digital Inputs

+
+
Digital Input 2
NO
Relay 1 COM
NC
NO
Relay 2 COM
NC

N
N

26

Con 1A*
*X2
Alarm I/O Connections
Ext. Alarm I/O Connections
Con 2A*
+ 1
Ext. Alarm I/O Connections Digital Input 3
- 2
+
Digital Input 4
+
Digital Input 5
+
Digital Input 6
NO
Relay 3 COM
NC
NO
Relay 4 COM
NC
NO
Relay 5 COM
NC

6 L1
7 L2

PE CON12
L1 CON11
L2 CON10
PE CON15
L1 CON14
L2 CON13
PE CON18
L1 CON17
L2 CON16
PE CON21
L1 CON20
L2 CON19

L3

Mains input

Backwiring FP2 Low


Current 4AC
4 rectifier positions
105833

Relay 6

PS 2
8
Smartpack Power - /
CAN bus
interconnections

Con8, pin 9-16

CAN port

Battery Current

For DIP switch


configuration see
Installation guide

+
-

DC/DC FP2 PS
4 DC/DC positions
273820

PS 3
8

Batt. block 1

Con8, pin 1-8

8
Con8, pin 9-16

Batt. block 2

+24V

Built-in Battery
Temperature Sensor

Batt. block 3

242100.502
I/O Monitor
CON202*
Ext. Alarm I/O Connections

Batt. block 4
0V

Battery Monitor
242100.300

Rear connections

- 48V Outer

X:*
Battery Connections

Batt. Symmetry 1
Batt. Symmetry 2
Batt. Symmetry 3
Batt. Symmetry 4

+
+
+
+
+
Batt. Fuse
-

CAN port
8

CAN port

Battery Current

+
-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

0V Outer
Terminal

Batt.
String *N

For DIP switch


configuration see
Installation guide

- F34- 16(LTE MU)


- F35- 32(UMTS RRU1)
- F36- 32(UMTS RRU2)
- F37- 32(UMTS RRU3)
- F38- 32(UMTS RRU4)
- F39- 32(LTE RRU1)
- F40- 32(LTE RRU2)

Terminal

1
2
3
4
5
6
7
8

+
+
+
+
+
Batt. Fuse
-

- F28- 16(GSM900 MU1)


- F29- 16(GSM1800 MU2)
- F30- 16(Spare)
- F31- 10(Free Cooling)
- F32- 16(Spare)
- F33- 16(UMTS MU)

- 48V Outer
Batt. Symmetry 1
Batt. Symmetry 2
Batt. Symmetry 3
Batt. Symmetry 4

- F7- 32(GSM900 RRU1)


- F8- 32(GSM900 RRU2)
- F9- 32(GSM900 RRU3)
- F10- 32(GSM900 RRU4)
- F11- 32(GSM1800 RRU1)
- F12- 32(GSM1800 RRU2)

- F27- 32(GSM1800 RRU4)

X:*
Battery Connections

CAN port

- F1- 10(Protection lifgts)


- F2- 16(Spare)
- F3- 32(TR1)
- F4- 32(TR2)

- F13- 32(GSM1800 RRU3)


- F14- 80(RBS900 -48)
- F15- 80(RBS1800 -48)

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Con8, pin 1-8

Battery Monitor
242100.300
8

NO
COM
NC

Terminal
Batt. block 1

1
2
3
4
5
6
7
8

15
CON5
System Connections

Smartpack
monitoring and
control unit
242100.118

15

Front connections

USB 2.0 type B port


(PC connection)

USB

CON4
Battery connections

9/15

CON3

Web/SNMP (ENET)

Batt. block 2

Customer
connections

8/26
CON2
Alarm I/O Connections

+24V

Built-in Battery
Temperature Sensor

Batt. block 3

CON1
Alarm I/O Connections

CAN port

Batt. block 4

Batt.
String 1

- F41- 32(LTE RRU3)


- F42- 32(LTE RRU4)
- F43- 80(NB2100 -48)
- F44- 80(eNB2600 -48)

CON303*
Ext. Alarm I/O Connections
Relay 1
Digital Input 1
Relay 2

Digital Input 2
Digital Input 3

Relay 3
Digital Input 4
Relay 4

Digital Input 5
Digital Input 6

+
+
+
+
+
+

1
2
3
4
5
6
7
8
9
10
11
12

Relay 5

com

nc

com

nc

- F45- 200 (RBS 900 MHz #1)

Relay 6

- F46- 200(RBS 1800 MHz #1)

8
8

Date

CAN port

Design

21 Jan. 2010

MK

Draw

Approved

Scale

Projection

MK

CAN port

0V Outer
Terminal

NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC

10

0V

Battery Strings
Circuits -48Vdc

- FB4

nc

LVLD1

10

8
Con8, pin 9-16

Con8, pin 1-8

Smartpack Power - /
CAN bus
interconnections

1
2
3
4
5
6
7
8
9
10

PE

com

*X1
Alarm I/O Connections
Digital Input 1

PS 1

1
2
3
4
5
6
7
8
9
10
11

LVLD2

Backwiring FP2 Low


Current 4AC
4 rectifier positions
105833

PE

POS. DIST.

JP1

NEG. DIST.

L3

POS. DIST.

L2

NEG. DIST.

Chassis

PE

+
+
+
-

Power Input

7
CON1

- FB2

nc

Low priority load circuits -48 Vdc


LVLD1

NEG. DIST.

POS. DIST.

com

System Connection

Con 5A* TB2


System Connections

15

- FB1

nc

High priority load


circuits -48 Vdc

Low priority load circuits -48 Vdc


LVLD2

SH1

Low priority load


circuits +24 Vdc

1 1 1
1 4 2

CAN port

1
Sym.

CR 061103NA
Alteration

220110/MK
Date/Sign

Schematic/Connection Drawing
FP2 16kWt -48V DC/DC -48V/+24V

Eltek
Copyright A/S Eltek. All rights reserved

Replace for

Consultant

Format

A3

Page

Draw. No.

1 of 1

201001

Replaced by

Rev.

Вам также может понравиться