Вы находитесь на странице: 1из 17

Procedure No.

R4G-80-FBR-OMG-PR-001 Annexure - II

Infrastructure Maintenance - RJIL

Form No
Rev No

R4G-80-FBR-SAT-PR-004 (Ribbon
fibre OFC)

LINK LOSS MEASUREMENT WITH LIGHT SOURCE & POWER METER FOR 0A RIBBON FIBRE CABLE

02

Cable Type (96/144/288F SM


G652 D, ECCS Armoured

Cable Vendor :

Section (From/ To)

BL NAGAR AG2 TO HDBD-RIL- 6512

24

HDBD_RIL-0141

Link No:

No Of Fibers

22

Contractor:

Date of Testing

10/15/2015

Report Date:

10/16/2015

Test Instrument Details:


Make
Sr No

Description

Side A

Model

Side B

JDSU

JDSU

JDSU

JDSU

Sr. No.

Side A

Side B

OLS-35

OLS-35

Side A

Light Source

OLP-34

Calibration date

Side B

Side A

Side B

OLS-35

OLS-35

A-055

A-055

No. of Splices as per OTDR report

OLP-34

OLP-34

AD-680

AD-680

Fiber Length (Avg.OTDR Length)

1.01216

OLP-34

Power meter

Output reference power level at 1310nm -

Fiber

Ribbion ID

Fiber Color

dB loss (F)
1310nm

1
2
3
4
5
6
7
8

1 Blue 1

9
10
11
12
13
14
15
16

1 Blue 2

17
18
19
20
21
22
23
24

1 Blue 3

Blue
Orange
Green
Brown
Slate
White
Red
Black
Blue
Orange
Green
Brown
Slate
White
Red
Black
Blue
Orange
Green
Brown
Slate
White
Red
Black

Output reference power level at 1550nm --7.48dbm

dB loss

1550nm

1310nm

LIVE
LIVE
1.8
1.12
3.13
0.1
1.43
2.98
0.88
1.27
0.33
0.54
0.88
0.47
0.54
0.45
0.3
0.41
0.7
0.88
0.52
0.34
0.44
2.74

dB loss (Av)

1550nm

LIVE
LIVE
1.77
0.8
2.54
0.03
1.68
2.57
0.64
1.08
0.36
0.44
0.81
0.07
0.75
0.04
0.89
0.59
0.17
0.32
0.31
0.31
0.02
2.35

1310nm

Result

1550nm

LIVE
LIVE
1.785
0.96
2.835
0.065
1.555
2.775
0.76
1.175
0.345
0.49
0.845
0.27
0.645
0.245
0.595
0.5
0.435
0.6
0.415
0.325
0.23
2.545

Remarks

Acceptable/ Not Acceptable


Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable

1. Acceptance criterion as per R4G-80-FBR-OMG-PR-001-Guidelines For OFN Acceptance Testing


2. Bi directional Total Link loss in dB at 1310 nm Link length X 0.35 + No. of splices X 0.10 + 1 dB
3. Bi directional Total Link loss in dB at 1550 nm Link length X 0.22 + No. of splices X 0.10 + 1 dB
5.Variation is max. & min. loss value shall not be more than 1 dB

Details
SIGNATURE
NAME
DATE

Contractor Representative

1.5226752

Construction Representative (HFCL)

Infrastructure Maintenance Representative

Form No

Procedure No. R4G-80-FBR-OMG-PR-001 Annexure - II


R4G-80-FBR-SAT-PR-004 (Ribbon
fibre OFC)

Infrastructure Maintenance - RJIL


Rev No

02
Cable Type (96/144/288F SM
G652 D, ECCS Armoured

Cable Vendor :

Section (From/
To)

HDBD-RIL- 6512 TO HDBD-RIL-0087

Link No:

HDBD_RIL-0141

Test Instrument Details:


Make
Sr No

Description

Side A

Model
Side B

JDSU

JDSU

JDSU

JDSU

Sr. No.

Side A

Side B

OLS-35

OLS-35

Side A

OLS-35

Light Source

OLP-34

OLP-34

OLP-34

Power meter

Output reference power level at 1310nm -

Fiber

Ribbion ID

Fiber Color

dB loss (F)
1310nm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 1 Black
Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 2 Black
Blue
Orange
Green
Brown

1 Blue 3

dB loss

1550nm

1310nm

LIVE
LIVE
1.3
0.93
0.41
0.91
1.54
0.78
2.2
1.1
0.83
1.1
1.24
0.48
1.1
5.3
0.99
0.99
1.17
0.72

1550nm

LIVE
LIVE
1.78
1.98
1.65
1.88
2
1.74
3.32
2.08
1.77
1.88
1.75
1.94
2.34
5.8
1.97
1.93
1.63
2.39

21
22
23
24

Slate
White
Red
1 Blue 3 Black

0.88
0.9
1.33
0.78

1.74
1.85
2.36
1.81

1. Acceptance criterion as per R4G-80-FBR-OMG-PR-001-Guidelines For OFN Acceptance Testing


2. Bi directional Total Link loss in dB at 1310 nm Link length X 0.35 + No. of splices X 0.10 + 1 dB
3. Bi directional Total Link loss in dB at 1550 nm Link length X 0.22 + No. of splices X 0.10 + 1 dB
5.Variation is max. & min. loss value shall not be more than 1 dB

Details
SIGNATURE
NAME
DATE

Contractor Representative

Construction Representati

80-FBR-OMG-PR-001 Annexure - II
LINK LOSS MEASUREMENT WITH LIGHT SOURCE & POWER METER FOR 0A RIBBON FIBRE CABLE

24

No Of Fibers

HDBD_RIL-0141

22

Contractor:

Sr. No.

Date of Testing

10/15/2015

Report Date:

10/16/2015

Calibration date

Side B

Side A

Side B

OLS-35

A-055

A-055

No. of Splices as per


OTDR report

OLP-34

AD-680

AD-680

Fiber Length
(Avg.OTDR Length)

2.18003

Output reference power level at 1550nm --7.48dbm

dB loss (Av)
1310nm

Result

1550nm

LIVE
LIVE
1.54
1.455
1.03
1.395
1.77
1.26
2.76
1.59
1.3
1.49
1.495
1.21
1.72
5.55
1.48
1.46
1.4
1.555

Acceptable/ Not Acceptable


Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable

Remarks

1.31
1.375
1.845
1.295

Testing
+ 1 dB
+ 1 dB

Acceptable
Acceptable
Acceptable
Acceptable

1.8796066

Construction Representative (HFCL)

Infrastructure Maintenance Representative

Form No

Infrastructure Maintenance - RJIL


Rev No

Procedure No. R4G-80-FBR-OMG-PR-001 Annexure - II


R4G-80-FBR-SAT-PR-004 (Ribbon
fibre OFC)
LINK LOSS MEASUREMENT WIT
02
Cable Type (96/144/288F SM
G652 D, ECCS Armoured

Cable Vendor :

Section (From/
To)

HDBD-RIL- 0087 TO HDBD-RIL-4401

Link No:

24

HDBD_RIL-0141

Test Instrument Details:


Make
Sr No

Description

Side A

JDSU

Model

Side B

JDSU

Sr. No.

Side A

Side B

OLS-35

OLS-35

Side A

Light Source

JDSU

JDSU

OLP-34

Side B

OLS-35

OLS-35

OLP-34

OLP-34

OLP-34

Power meter

Output reference power level at 1310nm -

Fiber

Ribbion ID

Fiber Color

dB loss (F)
1310nm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 1 Black
Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 2 Black
Blue
Orange
Green
Brown
Slate

1 Blue 3

dB loss

1550nm

1310nm

1.59
0.57
0.66
0.88
0.46
1.03
1.05
1.01
0.64
0.76
0.21
0.42
0.96
0.58
1.56
0.88
LIVE
LIVE
0.77
0.05
0.34

dB loss (Av)

1550nm

1.61
0.39
0.64
0.76
0.69
1
0.77
0.88
1.4
1.172
0.97
1.29
1.97
1.31
2.18
1.13
LIVE
LIVE
1.14
1
1.23

1310nm

22
23
24

White
Red
1 Blue 3 Black

1.5
0.36
0.64

1.59
1.3
1.66

1. Acceptance criterion as per R4G-80-FBR-OMG-PR-001-Guidelines For OFN Acceptance Testing


2. Bi directional Total Link loss in dB at 1310 nm Link length X 0.35 + No. of splices X 0.10 + 1 dB
3. Bi directional Total Link loss in dB at 1550 nm Link length X 0.22 + No. of splices X 0.10 + 1 dB
5.Variation is max. & min. loss value shall not be more than 1 dB

Details
SIGNATURE
NAME
DATE

Contractor Representative

Construction Representative (

MG-PR-001 Annexure - II

NK LOSS MEASUREMENT WITH LIGHT SOURCE & POWER METER FOR 0A RIBBON FIBRE CABLE

No Of Fibers

22

Contractor:

Date of Testing

10/15/2015

Report Date:

10/16/2015

Calibration date
Side A

Side B

A-055

A-055

No. of Splices as per


OTDR report

AD-680

AD-680

Fiber Length (Avg.OTDR


Length)

1.25084

Output reference power level at 1550nm --7.48dbm

dB loss (Av)

Result

1550nm

1.6
0.48
0.65
0.82
0.575
1.015
0.91
0.945
1.02
0.966
0.59
0.855
1.465
0.945
1.87
1.005
LIVE
LIVE
0.955
0.525
0.785

Acceptable/ Not Acceptable


Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable

Remarks

1.545
0.83
1.15

Acceptable
Acceptable
Acceptable

1.6751848

ruction Representative (HFCL)

Infrastructure Maintenance Representative

Form No

Procedure No. R4G-80-FBR-OMG-PR-001 Annexure - II


R4G-80-FBR-SAT-PR-004 (Ribbon
fibre OFC)

Infrastructure Maintenance - RJIL


Rev No

02
Cable Type (96/144/288F SM
G652 D, ECCS Armoured

Cable Vendor :

Section (From/
To)

HDBD-RIL-4401 TO HDBD-RIL-0887

Link No:

HDBD_RIL-0141

Test Instrument Details:


Make
Sr No

Description

Side A

JDSU

Model
Side B

JDSU

Sr. No.

Side A

Side B

OLS-35

OLS-35

Side A

OLS-35

Light Source

JDSU

JDSU

OLP-34

OLP-34

OLP-34

Power meter

Output reference power level at 1310nm -

Fiber

Ribbion ID

Fiber Color

dB loss (F)
1310nm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 1 Black
Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 2 Black
Blue
Orange
Green
Brown

1 Blue 3

dB loss

1550nm

1310nm

2.78
2.88
3.25
2.86
2.93
2.92
3.04
3.1
LIVE
LIVE
2.6
2.95
2.45
3.01
2.81
2.84
2.59
5.61
2.95
3.21

1550nm

2.98
2.7
2.67
2.31
3.67
2.76
4
3.62
LIVE
LIVE
3
3.32
3.1
2.9
2.67
3.13
2.98
5.44
2.64
2.86

21
22
23
24

Slate
White
Red
1 Blue 3 Black

2.59
2.3
2.72
2.84

3.18
2.69
2.81
3.13

1. Acceptance criterion as per R4G-80-FBR-OMG-PR-001-Guidelines For OFN Acceptance Testing


2. Bi directional Total Link loss in dB at 1310 nm Link length X 0.35 + No. of splices X 0.10 + 1 dB
3. Bi directional Total Link loss in dB at 1550 nm Link length X 0.22 + No. of splices X 0.10 + 1 dB
5.Variation is max. & min. loss value shall not be more than 1 dB

Details
SIGNATURE
NAME
DATE

Contractor Representative

Construction Representativ

-80-FBR-OMG-PR-001 Annexure - II
LINK LOSS MEASUREMENT WITH LIGHT SOURCE & POWER METER FOR 0A RIBBON FIBRE CABLE

24

No Of Fibers

HDBD_RIL-0141

22

Contractor:

Sr. No.

Date of Testing

10/14/2015

Report Date:

10/16/2015

Calibration date

Side B

Side A

Side B

OLS-35

A-055

A-055

No. of Splices as per


OTDR report

13

OLP-34

AD-680

AD-680

Fiber Length
(Avg.OTDR Length)

14.27486

Output reference power level at 1550nm --8.62dbm

dB loss (Av)
1310nm

Result

Acceptable/ Not Acceptable


2.88
Acceptable
2.79
Acceptable
2.96
Acceptable
2.585
Acceptable
3.3
Acceptable
2.84
Acceptable
3.52
Acceptable
3.36
Acceptable
LIVE
Acceptable
LIVE
Acceptable
2.8
Acceptable
3.135
Acceptable
2.775
Acceptable
2.955
Acceptable
2.74
Acceptable
2.985
Acceptable
2.785
Acceptable
5.525
Acceptable
2.795
Acceptable
3.035
Acceptable

1550nm

Remarks

2.885
2.495
2.765
2.985

Testing
+ 1 dB
+ 1 dB

Acceptable
Acceptable
Acceptable
Acceptable

5.4404692

Construction Representative (HFCL)

Infrastructure Maintenance Representative

Form No

Procedure No. R4G-80-FBR-OMG-PR-001 Annexure - II


R4G-80-FBR-SAT-PR-004 (Ribbon
fibre OFC)

Infrastructure Maintenance - RJIL


Rev No

02
Cable Type (96/144/288F SM
G652 D, ECCS Armoured

Cable Vendor :

Section (From/
To)

HDBD-RIL-0887 TO ECIL AG2

Link No:

HDBD_RIL-0141

Test Instrument Details:


Make
Sr No

Description

Light Source

Side A

JDSU

Side B

JDSU

Sr. No.

Side A

Side B

OLS-35

OLS-35

Side A

OLS-35
JDSU

Model

JDSU

OLP-34

OLP-34

OLP-34

Power meter

Output reference power level at 1310nm -

Fiber

Ribbion ID

Fiber Color

dB loss (F)
1310nm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 1 Black
Blue
Orange
Green
Brown
Slate
White
Red
1 Blue 2 Black
Blue
Orange
Green
Brown
Slate

1 Blue 3

dB loss

1550nm

1310nm

0.73
0.63
0.43
0.58
0.47
0.99
0.9
1.3
0.82
0.58
0.7
0.6
0.67
0.39
LIVE
LIVE
1.07
1.02
0.93
0.79
0.44

1550nm

0.39
0.57
0.46
0.25
0.64
0.45
0.36
0.4
0.67
1.06
0.51
0.41
0.37
0.64
LIVE
LIVE
0.64
0.31
0.69
0.43
0.98

22
23
24

White
Red
1 Blue 3 Black

0.94
0.84
0.88

0.56
0.66
1.02

1. Acceptance criterion as per R4G-80-FBR-OMG-PR-001-Guidelines For OFN Acceptance Testing


2. Bi directional Total Link loss in dB at 1310 nm Link length X 0.35 + No. of splices X 0.10 + 1 dB
3. Bi directional Total Link loss in dB at 1550 nm Link length X 0.22 + No. of splices X 0.10 + 1 dB
5.Variation is max. & min. loss value shall not be more than 1 dB

Details
SIGNATURE
NAME
DATE

Contractor Representative

Construction Representativ

G-80-FBR-OMG-PR-001 Annexure - II
LINK LOSS MEASUREMENT WITH LIGHT SOURCE & POWER METER FOR 0A RIBBON FIBRE CABLE

24

No Of Fibers

HDBD_RIL-0141

22

Contractor:

Sr. No.

Date of Testing

10/14/2015

Report Date:

10/16/2015

Calibration date

Side B

Side A

Side B

OLS-35

A-055

A-055

No. of Splices as per


OTDR report

OLP-34

AD-680

AD-680

Fiber Length (Avg.OTDR


Length)

4.20434

Output reference power level at 1550nm --8.62dbm

dB loss (Av)
1310nm

Result

1550nm

0.56
0.6
0.445
0.415
0.555
0.72
0.63
0.85
0.745
0.82
0.605
0.505
0.52
0.515
LIVE
LIVE
0.855
0.665
0.81
0.61
0.71

Acceptable/ Not Acceptable


Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable

Remarks

0.75
0.75
0.95

e Testing
+ 1 dB
+ 1 dB

Acceptable
Acceptable
Acceptable

2.4249548

Construction Representative (HFCL)

Infrastructure Maintenance Representative

Вам также может понравиться