Вы находитесь на странице: 1из 545

JUMP TO A SECTION IN THE TABLE OF CONTENTS:

ABCDEFGHIJKLM

Standard
Plans
M 21-01
August 5, 2013

Engineering and Regional Operations


Development Division, Design Office

Americans with Disabilities Act (ADA) Information


Materials can be provided in alternative formats by calling the ADA Compliance Manager
at 3607057097. Persons who are deaf or hard of hearing may contact that number via the
WashingtonRelay Service at 711.

Title VI Notice to the Public


It is Washington State Department of Transportation (WSDOT) policy to ensure noperson shall,
on thegrounds of race, color, national origin, or sex, as provided by Title VI of the Civil Rights Act
of 1964, be excluded from participation in, be denied the benefits of, orbe otherwise discriminated
against under any of its federally funded programs and activities. Anyperson who believes his/her
Title VI protection has been violated may file a complaint with WSDOTs Office of Equal
Opportunity (OEO). For Title VI complaint forms and advice, pleasecontact OEOs Title VI
Coordinator at 3607057082 or5093246018.

To get the latest information on WSDOT publications, sign up for individual email updates at
www.wsdot.wa.gov/publications/manuals.
Washington State Department of Transportation
Engineering and Regional Operations
Development Division, Design Office
PO Box 47329
Olympia, WA 98504-7329
Email: designstandards@wsdot.wa.gov
www.wsdot.wa.gov/design/standards/plans.htm

Foreword
This manual contains standard engineering drawings used for road, bridge, and
municipal construction. These drawings have been prepared under the direct supervision of a Washington State licensed professional engineer, who is knowledgeable in
the specialized field of civil engineering depicted in each drawing. This manual standardizes fabrication, installation, and construction methods for specific items of work,
and complements the contract documents and the Standard Specifications for Road,
Bridge, and Municipal Construction.
Updating the manual is a continual process and revisions are issued periodically.
Questions, comments, and recommendations for changes are welcome.
Contact the Design Standards Team at:
(360) 705-7256 (phone)
designstandards@wsdot.wa.gov (e-mail)
For contact via conventional mail, the Comment Request Form on the reverse side of
this page is provided to facilitate routing and prompt delivery. Making a copy will
preserve the original form for future use. Attach a copy of the form as a cover sheet
when sending comments or sketches made on other documents, such as marked
copies of specific Standard Plans. Your questions, comments, and/or recommendations should be sent to:
Design Standards
Transportation Building
Olympia, WA 98504-7329.
Further information, as well as Bentley MicroStation (.dgn) CAD files, Adobe Acrobat
(.pdf) files, and some AutoCAD (.dwg) CAD files, can be found on the Design
Standards website at:
http://www.wsdot.wa.gov/eesc/design/designstandards
Contact the Engineering Publications Office at (360) 705-7430 if you require
additional copies of this manual.

_____________________________
Pasco Bakotich III
State Design Engineer

Standard Plans for Road, Bridge, and Municipal Construction

Page 1

Comments
From: ________________________________________
________________________________________
________________________________________
________________________________________

Date: ____________________
Phone: ____________________

To: Design Standards


Washington State Department of Transportation
Transportation Building
PO Box 47329
Olympia, WA 98504-7329

Subject: Standard Plans Manual Comment

Comment:

See attached

Preserve this original for future use Submit copies only


Page 2

Standard Plans for Road, Bridge, and Municipal Construction

Contents
Plan No.

Section A

Plan Title

Roadway Construction

A-10.10-00
A-10.20-00
A-10.30-00
A-20.10-00
A-30.10-00
A-30.15-00
A-30.30-01
A-30.35-00
A-40.00-00
A-40.10-02
A-40.15-00
A-40.20-02
A-40.50-01
A-50.10-00
A-50.20-01
A-50.30-00

Survey Stakes
Survey Monument Types 1 and 2
Monument and Cover
Slope Treatment
Concrete Slope Protection
Semi-open Concrete Masonry Slope Protection
Wire Mesh Slope Protection
Slope Protection Anchors
Dowel Bar Baskets
Cement Concrete Pavement Joints
PCC Pavement Isolation Joints
Bridge Transverse Joint Seals
Bridge Approach Slab
Embankment Widening at Bridge End with Wing Wall
Embankment Widening at Bridge End with Curtain Wall
Embankment Widening at Bridge End with "L" Shaped
Abutment
Embankment Widening at Bridge End with Sidewalk
Cement Concrete Pavement Repair
Dowel Bar Retrofit for Cement Concrete Pavement
Bridge Deck Transition for HMA Overlay
HMA Overlay Further Deck Preparation

A-50.40-00
A-60.10-01
A-60.20-02
A-60.30-00
A-60.40-00

Section B

Publication Approval Date

8/7/07
10/5/07
10/5/07
8/31/07
11/8/07
11/8/07
6/16/11
10/12/07
8/11/09
6/2/11
8/11/09
5/29/13
6/2/11
11/17/08
9/22/09
11/17/08
11/17/08
10/14/09
6/2/11
11/8/07
8/31/07

2 Sheets

2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets

2 Sheets
2 Sheets

Drainage Structures and Hydraulics

B-5.20-01
B-5.40-01
B-5.60-01
B-10.20-01
B-10.40-00
B-10.60-00
B-15.20-01
B-15.40-01
B-15.60-01
B-20.20-02
B-20.40-03
B-20.60-03
B-25.20-01
B-25.60-00
B-30.10-01
B-30.20-02
B-30.30-01
B-30.40-01
B-30.50-01
B-30.70-03
B-30.80-00
B-30.90-01
B-35.20-00

Catch Basin Type 1


Catch Basin Type 1L
Catch Basin Type 1P (for Parking Lot)
Catch Basin Type 2
Catch Basin Type 2 with Flow Restrictor
Catch Basin Type 2 with Baffle Type Flow Restrictor
Manhole Type 1
Manhole Type 2
Manhole Type 3
Drywell Type 1 (for Swale)
Drywell Type 2 (with Pipe Inlet)
Drywell Type 3 (with At-Grade Inlet)
Combination Inlet
Concrete Inlet
Rectangular Frame (Reversible)
Rectangular Solid Metal Cover
Rectangular Vaned Grate
Rectangular Bi-Directional Vaned Grate
Rectangular Herringbone Grate
Circular Frame (Ring) and Cover
Circular Grate
Miscellaneous Details for Drainage Structures
Grate Inlet Type 1 (Cast-In-Place)

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

6/16/11
6/16/11
6/16/11
2/7/12
6/1/06
6/8/06
2/7/12
2/7/12
2/7/12
3/16/12
3/16/12
3/15/12
3/15/12
6/1/06
4/26/12
4/26/12
4/26/12
4/26/12
4/26/12
4/26/12
6/8/06
9/20/07
6/8/06

Page 3

Contents
Plan No.

B-35.40-00
B-40.20-00
B-40.40-01
B-45.20-00
B-45.40-00
B-50.20-00
B-55.20-00
B-60.20-00
B-60.40-00
B-65.20-01
B-65.40-00
B-70.20-00
B-70.60-00
B-75.20-01
B-75.50-01
B-75.60-00
B-80.20-00
B-80.40-00
B-82.20-00
B-85.10-01
B-85.20-00
B-85.30-00
B-85.40-00
B-85.50-01
B-90.10-00
B-90.20-00
B-90.30-00
B-90.40-00
B-90.50-00
B-95.20-01
B-95.40-00

Section C
C-1
C-1a
C-1b
C-1c
C-1d
C-2
C-2a
C-2b
C-2c
C-2d

Page 4

Plan Title

Publication Approval Date

Grate Inlet Type 2


Welded Grates for Grate Inlet
Frame and Dual Vaned Grates for Grate Inlet
Drop Inlet Type 1
Drop Inlet Type 2
Grates for Drop Inlet
Pipe Zone Bedding and Backfill
Connection Details for Dissimilar Culvert Pipe
Coupling Bands for Corrugated Metal Pipe
Animal Underpass
Equipment Underpass
Beveled End Sections (for Culverts 30 Diameter or Less)
Flared End Sections
Headwalls for Culvert Pipe and Underpass
Type 1 Safety Bars for Stepped Culvert Pipe or Pipe Arch
Type 2 Safety Bars for Culvert Pipe or Pipe Arch (On Cross
Road)
Tapered End Section with Type 3 Safety Bars
Tapered End Section with Type 4 Safety Bars (On Cross
Road)
Residential Storm Drain, Under Sidewalk
Vertical Connection (for Sanitary Sewer Use)
Side Sewer Connection (for Sanitary Sewer Use)
Standing Side Sewer Connection (for Sanitary Sewer
Use)
8 Inch Sewer Clean-Out (for Sanitary Sewer Use)
Drop Connections (for Sanitary Sewer Use)
Hydrant Setting Types A and B
2 Inch Blowoff Assembly
Combination Air Release / Air Vacuum Valve Assembly
Concrete Thrust Block
Concrete Thrust Block for Convex Vertical Bends
Median Barrier Drainage Installation
Inlet Placement at Bridge End

6/8/06
6/1/06
6/16/10
6/1/06
6/1/06
6/1/06
6/1/06
6/8/06
6/1/06
4/26/12
6/1/06
6/1/06
6/1/06
6/10/08
6/10/08
6/8/06

2 Sheets

6/8/06
6/1/06
6/1/06
6/10/08
6/1/06
6/1/06
6/8/06
6/10/08
6/8/06
6/8/06
6/8/06
6/8/06
6/8/06
2/3/09
6/8/06

Traffic Barrier
Beam Guardrail Types 1 ~ 4 (W-Beam)
Beam Guardrail (Thrie Beam)
Beam Guardrail Posts and Blocks
Beam Guardrail
Thrie Beam Guardrail Reducer Section
Guardrail Placement (Cases 1, 2 & 3)
Guardrail Placement (Cases 4, 5 & 6)
Guardrail Placement (Cases 7 & 8)
Guardrail Placement Median Bull Nose (Cases 9A, 9B &
9C)
Guardrail Placement (Cases 10A, 10B & 10C)

6/16/11
10/14/09
6/16/11
5/30/97
10/31/03
1/6/00
6/21/06
6/21/06
6/21/06

2 Sheets
2 Sheets

6/21/06

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Contents
Plan No.

C-2e
C-2f
C-2g
C-2h
C-2i
C-2j
C-2k
C-2n
C-2o
C-2p
C-3
C-3a
C-3b
C-3c
C-4b
C-4e
C-4f
C-6
C-6a
C-6c
C-6d
C-6f
C-7
C-7a
C-8
C-8a
C-8b
C-8e
C-8f
C-10
C-16a
C-16b
C-20.10-01
C-20.14-02
C-20.15-01
C-20.18-01
C-20.19-01
C-20.40-03

Plan Title

Publication Approval Date

Guardrail Placement (Cases 11A, 11B & 11C)


Guardrail Placement Weak Post Intersection Design
(8' - 6" Max. Radius) (Cases 12AC, 12AD, 12BC & 12BD)
Guardrail Placement Weak Post Intersection Design
(35' Max. Radius) (Cases 13AC, 13AD, 13BC & 13BD)
Guardrail Placement (Case 14)
Guardrail Placement (Case 15)
Guardrail Placement (Cases 16, 17 & 18)
Guardrail Placement 12 - 6 Span (Cases 19A & 19B)
Guardrail Placement 18 - 9 Span (Case 20)
Guardrail Placement 25 Span (Case 21)
Guardrail Placement Strong Post Intersection Design
(Cases 22AC, 22AD, 22BC & 22BD)
Beam Guardrail Transition Sections (Types 1, 1A, & 1B)
Beam Guardrail Transition Sections (Types 2, 4, 5, & 6)
Beam Guardrail Transition Sections (Types 10 ~ 15)
Beam Guardrail Transition Sections (Types 16, 17, & 18)
Beam Guardrail Flared Terminal
Beam Guardrail Non-Flared Terminal
Beam Guardrail Bull Nose Terminal
Beam Guardrail Anchor Type 1
Beam Guardrail Anchor Type 2
Beam Guardrail Anchor Type 4
Beam Guardrail Anchor Type 5
Beam Guardrail Anchor Type 7
Beam Guardrail End Sections
Thrie Beam End Sections
Concrete Barrier Type 2
Concrete Barrier Type 4 and Transition Section
Concrete Barrier Light Standard Section
Precast Concrete Barrier Anchor ~ Type 3 (Permanent)
Concrete Barrier Transition, Type 2 to Bridge F-Shape
Box Culvert Guardrail Steel Post
Traffic Barrier Shoulder Widening
~ for Shoulders 8.0' and Wider
Traffic Barrier Shoulder Widening
~ for Shoulders Less Than 8.0' Wide
Beam Guardrail Type 31
Beam Guardrail Type 31 Placement (Cases 1-31, 2-31, &
3-31)
Beam Guardrail Type 31 Placement (Cases 4-31 & 5-31)
Beam Guardrail Type 31 Placement (Cases 10A-31, 10B31 and 10C-31)
Beam Guardrail Type 31 Placement (Cases 11A-31, 11B31 and 11C-31)
Beam Guardrail Type 31 Placement
~ 12'-6", 18'-9", or 25'-0" Span

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

6/21/06
3/14/97
7/27/01
3/28/97
3/28/97
6/12/98
7/27/01
7/27/01
7/13/01
10/31/03
7/2/12
10/4/05
6/27/11
6/27/11
6/8/06
2/20/03
7/2/12
5/30/97
10/14/09
1/6/00
5/30/97
7/25/97
6/16/11
6/16/11
2/10/09
7/25/97
6/27/11
2/21/07
6/30/04
6/3/10
6/3/10

2 Sheets

4 Sheets
2 Sheets

2 Sheets
2 Sheets

2 Sheets

6/3/10
6/20/13
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12

Page 5

Contents
Plan No.

C-20.42-03
C-20.45-01
C-22.14-02
C-22.16-03
C-22.40-02
C-22.45-00
C-23.60-02
C-24.10-00
C-25.18-03
C-25.20-05
C-25.22-04
C-25.26-02
C-25.80-02
C-40.14-02
C-40.16-02
C-40.18-02
C-70.10-00
C-75.10-00
C-75.20-00
C-75.30-00
C-80.10-00
C-80.20-00
C-80.30-00
C-80.40-00
C-80.50-00
C-85.10-00
C-85.11-00
C-85.14-00
C-85.15-00
C-85.16-00
C-85.18-00
C-85.20-00
C-90.10-00

Page 6

Plan Title

Publication Approval Date

Guardrail Placement Strong Post ~ Type 31 Intersection


Design
Beam Guardrail Type 31 - DS (Double sided) (W-Beam)
Beam Guardrail Type 1 Buried Terminal Type 2
Beam Guardrail Type 31 Buried Terminal Type 2
Beam Guardrail Type 31 Non-Flared Terminal All Steel
Posts (All posted speeds)
Beam Guardrail Type 31 Non-Flared Terminal Steel Posts
(Posted speed-40 mph and below)
Beam Guardrail (Type 31) Anchor Type 10
Guardrail Connections to Bridge Rail or Concrete Barrier
Beam Guardrail (Type 31) Transition Section Type 20
Beam Guardrail (Type 31) Transition Section Type 21
Beam Guardrail (Type 31) Transition Section Type 22
Beam Guardrail (Type 31) Transition Section Type 23
Beam Guardrail Type 31 to Beam Guardrail Type 1
Adapter
Barrier Placement Cable to Thrie Beam Bull Nose
Connection
Barrier Placement ~ Cable to W-Beam Shielding for
Redirectional Landform
Barrier Placement ~ Cable Barrier Shielding for
Redirectional Landform
Single Slope Concrete Barrier (Pre-Cast)
Single Slope Concrete Barrier (Pre-Cast)Transition Section
Single Slope Concrete Barrier (Pre-Cast) Vertical Back
Single Slope Concrete Barrier (Pre-Cast) Terminal
Single Slope Concrete Barrier (Cast-in-Place) Dual Faced
Single Slope Concrete Barrier (Cast-in-Place) Terminal
Single Slope Concrete Barrier (Cast-in-Place) Trans.
Section
Single Slope Concrete Barrier (Cast-in-Place) Vertical Back
Concrete Barrier Transition, Type 2 to Single Slope
Single Slope Concrete Barrier Placement (Split)
Single Slope Concrete Barrier Placement (Wrap)
Single Slope Concrete Barrier Light Standard Foundation
Single Slope Concrete Barrier (42") Light Standard
Foundation
Single Slope Concrete Barrier Sign Bridge Foundation
Single Slope Concrete Barrier Transition for Monotube Sign
Support
Single Slope Concrete Barrier Truss-Type Sign Foundation
Impact Attenuator Inertial Barrier Configurations

7/2/12
7/2/12
6/16/11
4/18/12
6/16/10
6/16/11
6/21/12
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12
7/2/12
4/18/12
4/18/12
4/18/12
4/18/12
4/18/12
4/18/12
4/18/12

3 Sheets

3 Sheets

4/18/12
4/18/12
4/18/12
4/18/12
6/16/11
6/16/11
6/16/11
6/16/11

2 Sheets

6/16/11
7/3/08

2 Sheets

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Contents
Plan No.

Section D
D-2.04-00
D-2.06-01
D-2.08-00
D-2.14-00
D-2.16-00

D-2.18-00
D-2.20-00
D-2.32-00
D-2.34-01
D-2.36-02
D-2.42-00
D-2.44-00

D-2.46-00
D-2.48-00

D-2.60-00
D-2-62-00
D-2.64-01
D-2.66-00

D-2.68-00
D-2.80-00
D-2.82-00
D-2.84-00
D-2.86-00
D-2.88-00

Plan Title

Publication Approval Date

Retaining, Noise Barrier, and Geosynthetic Walls


Noise Barrier Wall Type 2 (CIP Wall on Spread Footing)
Noise Barrier Wall Type 3 ( on Offset Spread Footing)
Noise Barrier Wall Type 4 ( on Shaft Foundation)
Noise Barrier Wall Type 6 (w/Traffic Barrier on Spread
Ftg.)(CIP Conc. w/ Traffic Barrier on Spread Footing)
Noise Barrier Wall Type 6SS (w/S. S. Traffic Barrier on
Spread Ftg.)(CIP Conc. w/ S. S. Traffic Barrier on Spread
Footing)
Noise Barrier Wall Type 7 (w/Traffic Barrier on Shaft
Fdn.)(CIP Conc. w/ Traffic Barrier on Shaft Foundation)
Noise Barrier Wall Type 7SS (w/Traffic Barrier on Shaft
Fdn.)(CIP Conc. w/ S. S. Traffic Barrier on Shaft Fdn.)
Noise Barrier Wall Type 9 (Precast Wall on Spread
Footing)
Noise Barrier Wall Type 10 ( on Offset Spread Footing)
Noise Barrier Wall Type 11 (... on Shaft Foundation)
Noise Barrier Wall Type 13 (...w/Traffic Barrier on Spread
Ftg.)(Precast Conc. w/Traffic Barrier on Spread Footing)
Noise Barrier Wall Type 13SS (w/S. S. Traffic Barrier on
Spread Ftg.)(Precast w/ S. S. Traffic Barrier on Spread
Footing)
Noise Barrier Wall Type 14 (w/Traffic Barrier on Shaft
Fdn.)(Precast Conc. w/ Traffic Barrier on Shaft Foundation)
Noise Barrier Wall Type 14SS (w/S. S. Traffic Barrier on
Shaft Fdn.)(Precast Conc. w/ Single Slope Traffic Barrier
on Shaft Fdn.)
Noise Barrier Wall Type 16 (Masonry on Trench Footing)
Noise Barrier Wall Type 17 (Masonry on Spread Footing)
Noise Barrier Wall Type 18 (Masonry on Offset Spread
Ftg.)
Noise Barrier Wall Type 19 (on Shaft w/Grade beam
Fdn.)
(Masonry on Shaft with Grade Beam Foundation)
Noise Barrier Wall Type 20 (Masonry on Shaft Foundation)
Noise Barrier Wall Access Door Type 1 (for CIP Wall on
Offset Spread Ftg.)
Noise Barrier Wall Access Door Type 2 (w/Traffic Barrier)
Noise Barrier Wall Access Door Type 3 (for Precast Wall
on Shaft Fdn.)
Noise Barrier Wall Access Door Type 4 (w/Traffic Barrier
on Shaft Fdn.)
Noise Barrier Wall Access Door Type 5 (for Masonry Wall)

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

11/10/05
1/6/09
11/10/05
11/10/05

2 Sheets
2 Sheets
2 Sheets

11/10/05

11/10/05
11/10/05
11/10/05

2 Sheets

1/6/09
1/6/09
11/10/05

2 Sheets
3 Sheets

11/10/05

11/10/05

2 Sheets

11/10/05

2 Sheets

11/10/05
11/10/05
1/6/09

2 Sheets
2 Sheets
2 Sheets

11/10/05

2 Sheets

11/10/05
11/10/05

2 Sheets

11/10/05
11/10/05

2 Sheets

11/10/05

2 Sheets

11/10/05

Page 7

Contents
Plan No.

D-2.92-00
D-3.09-00
D-3.10-01
D-3.11-02
D-3.15-02
D-3.16-02
D-3.17-01
D-4
D-6
D-10.10-01
D-10.15-01
D-10.20-00
D-10.25-00
D-10.30-00
D-10.35-00
D-10.40-01
D-10.45-01
D-15.10-01
D-15.20-02
D-15.30-01

Section E
E-1
E-2
E-4
E-4a

Section F
F-10.12-02
F-10.16-00
F-10.18-00
F-10.40-02
F-10.42-00
F-10.62-01
F-10.64-02
F-30.10-02
F-40.12-02
F-40.14-02
F-40.15-02
F-40.16-02
F-45.10-01
F-80.10-02

Page 8

Plan Title

Publication Approval Date

Noise Barrier Wall Access Door & Frame


Permanent Geosynthetic Wall
Cast-In-Place Permanent Geosynthetic Wall Fascia and
Facing
Precast Permanent Geosynthetic Wall Fascia
Permanent Geosynthetic Wall Single Slope Barrier
Permanent Geosynthetic Wall F-Shape Barrier
Permanent Geosynthetic Wall Expansion Joint Details
Backfill and Drainage for Retaining Walls
Gabions
Reinforced Concrete Retaining Wall Type 1 and 1SW
Reinforced Concrete Retaining Wall Type 2 and 2SW
Reinforced Concrete Retaining Wall Type 3 and 3SW
Reinforced Concrete Retaining Wall Type 4 and 4SW
Reinforced Concrete Retaining Wall Type 5
Reinforced Concrete Retaining Wall Type 6
Reinforced Concrete Retaining Wall Type 7
Reinforced Concrete Retaining Wall Type 8
Traffic Barrier Details for Reinf. Conc. Retaining Walls
Traffic Barrier Details for Reinf. Conc. Retaining Walls
Traffic Barrier Details for Reinf. Conc. Retaining Walls

11/10/05
5/17/12
5/29/13

2 Sheets
4 Sheets

5/29/13
6/10/13
5/29/13
5/17/12
12/11/98
6/19/98
12/2/08
12/2/08
7/8/08
7/8/08
7/8/08
7/8/08
12/2/08
12/2/08
12/2/08
6/2/11
12/2/08

2 Sheets

2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets
2 Sheets

Bridges and Trestles


Date Numeral Placement on Bridge Traffic Barrier
Pile or Frame Detour Bridge with Asphalt Overlay
Precast Prestressed Concrete Piles
Precast Prestressed Concrete Piles Handling & Capping

2/21/07
5/29/98
8/27/03
8/27/03

2 Sheets

Curbs, Sidewalks, and Driveways


Cement Concrete Curbs
Cement Concrete Curb and Gutter Pan
Roundabout Cement Concrete Curbs
Extruded Curb Placement
Extruded Curb
Precast Concrete Sloped Mountable Curb
Precast Concrete Dual Faced Sloped Mountable Curb
Cement Concrete Sidewalk
Parallel Curb Ramp
Combination Curb Ramps
Perpendicular Curb Ramps
Single Direction Curb Ramps
Detectable Warning Surface
Cement Concrete Driveway Entrance Types 1, 2, 3, & 4

6/16/11
12/20/06
6/27/11
6/21/12
1/23/07
9/5/07
7/3/08
6/20/13
6/20/13
6/20/13
6/20/13
6/20/13
6/21/12
3/15/12

2 Sheets

2 Sheets

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Contents
Plan No.

Plan Title

Section G
G-10.10-00
G-20.10-00
G-22.10-01
G-24.10-00
G-24.20-01
G-24.30-01
G-24.40-03
G-24.50-02
G-24.60-02
G-25.10-04
G-30.10-02
G-50.10-01
G-60.10-02
G-60.20-01
G-60.30-01
G-70.10-02
G-70.20-02
G-70.30-02
G-90.10-01
G-90.20-02
G-90.30-02
G-90.40-01
G-95.10-01
G-95.20-02
G-95.30-02

Section H

Publication Approval Date

Signs and Sign Supports


Milepost
Ground Mounted Sign Placement
Timber Sign Support
Steel Sign Support Type AP Installation Details
Steel Sign Support Type AS Installation Details
Steel Sign Support, Types PL, PL-T, & PL-U, Inst. Det.
Steel Sign Support Types SB-1, SB-2 & SB-3 Installation
Details
Steel Sign Support Types ST-1 ~ ST-4, Installation
Details
Steel Sign Support Types TP-A & TP-B, Installation
Details
Steel Sign Support Foundation Details
Sign Installation on Signal and Light Standards
Sign Bracing
Cantilever Sign Structure (Truss-Type)
Cantilever Sign Structure (Truss-Type) Foundation Type
1
Cantilever Sign Structure (Truss-Type) Fdn., Types 2 & 3
Sign Bridge (Truss-Type)
Sign Bridge (Truss-Type) Foundation Type1
Sign Bridge (Truss-Type) Foundation Types 2 & 3
Overhead Sign Bracing and Lighting Placement
Overhead Sign Mounting (Monotube Structure)
Overhead Sign Mounting (Truss Structure)
Overhead Sign Lighting Details
Maintenance Walkway for Sign Bridges
Maintenance Walkway Mounting for Monotube Sign
Bridge
Maintenance Walkway Mounting for Truss-Type Sign
Bridge

9/20/07
9/20/07
7/3/08
11/8/07
2/7/12
2/7/12
6/20/13

3 Sheets

2 Sheets
4 Sheets

6/20/13
5/20/13

2 Sheets

6/10/13
6/20/13
6/20/13
6/10/13
6/27/11

2 Sheets
2 Sheets
4 Sheets
2 Sheets

6/27/11
6/10/13
6/10/13
6/10/13
5/11/11
3/25/13
3/22/13
10/14/09
6/2/11
6/2/11

2 Sheets
4 Sheets

6/2/11

2 Sheets

7/3/08
7/3/08
10/12/07
9/20/07
7/3/08
7/3/08
2/7/12
2/16/12
2/7/12

2 Sheets
2 Sheets
2 Sheets

3 Sheets
3 Sheets

Roadside and Site Development

H-10.10-00
H-10.15-00
H-30.10-00
H-32.10-00
H-60.10-01
H-60.20-01
H-70.10-01
H-70.20-01
H-70.30-02

Tree and Shrub Planting Details


Live Stake Installations
Crest Gage
Automated Ground Water Monitoring Well
Bollard Type 1
Bollard Type 2
Mailbox Support Type 1
Mailbox Support Type 2
Mailbox Support Type 3

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Page 9

Contents
Plan No.

Section I
I-10.10-01
I-30.10-02
I-30.15-02
I-30.16-00
I-30.17-00
I-30.20-00
I-30.30-01
I-30.40-01
I-30.60-00
I-40.10-00
I-40.20-00
I-50.20-01
I-60.10-01
I-60.20-01
I-80.10-01

Section J
J-3
J-3b

Plan Title

Publication Approval Date

Site Preservation and Erosion Control


High Visibility Fence
Silt Fence with Backup Support
Silt Fence
High Visibility Silt Fence with Backup Support
High Visibility Silt Fence
Erosion Control At Culvert Ends
Wattle Installation On Slope
Compost Sock
Erosion Control Details Coir Log Placement
Temporary Silt Fence for Inlet Protection In Unpaved
Areas
Storm Drain Inlet Protection
Check Dams on Channels
Biodegradable Erosion Control Blanket Placement for
Slopes
Biodegradable Erosion Control Blanket Placement for
Ditches
Miscellaneous Erosion Control Details

8/11/09
3/22/13
3/22/13
3/22/13
3/22/13
9/20/07
6/10/13
6/10/13
5/29/13
9/20/07
9/20/07
6/10/13
6/10/13
6/10/13
8/11/09

Illumination, Signals, and ITS


Type A, B, and C Service Lighting Details
Service Cabinet Type B Modified (0 - 200 Amp Type,

8/1/97
3/4/05

2 Sheets
2 Sheets

120/240 Single Phase)

J-3c
J-10
J-10.10-01
J-10.15-00
J-10.22-00
J-15.10-00
J-15.15-00
J-20.10-02
J-20.11-01
J-20.15-02
J-20.16-01
J-20.20-02
J-20.26-01
J-21.10-03
J-21.15-01
J-21.16-01
J-21.17-01

Page 10

Service Cabinet Type D (0 - 200 Amp Type, 120/240 Single


Phase)
Electrical Conduit Placement
Cabinet Orientation, Conduit Layout and Foundation
Detail
Cabinet Enclosure on Slope
Service Cabinet Type E (0 - 200 Amp Type, 240/480
Single Phase)
Timber Light Standard
Span Wire Installation
Accessible Pedestrian PushButton Post (PPB) and
Foundation
Accessible Pedestrian PushButton (PPB) with Curb
Base
Accessible Breakaway Pedestrian PushButton (PPB)
Post
Pedestrian Signal Standard (Type PS) Details
Pedestrian Signal Standard (Type PS) Electrical Details
Accessible Pedestrian PushButton (PPB) Details
Type PS, Type 1, RM, and FB Signal Standard
Foundation Details
Type 1 Signal Standard Details
Flashing Beacon Type 1 Signal Standard Details
Flashing Beacon Type 1 Signal Standard Electrical
Details

6/24/02
7/18/97
5/11/11

5 Sheets

7/2/12
5/29/13

2 Sheets

5/18/12
6/16/10
6/10/13
6/10/13

2 Sheets

6/10/13
7/12/12
5/20/13
7/12/12
6/10/13

2 Sheets
2 Sheets

6/10/13
6/10/13
6/10/13

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Contents
Plan No.

J-21.20-01
J-22.15-01
J-22.16-02
J-26.10-02
J-26.15-01
J-27.10-00
J-27.15-00
J-28.10-01
J-28.22-00
J-28.24-00
J-28.26-01
J-28.30-02
J-28.40-01
J-28.42-00
J-28.45-01
J-28.50-02
J-28.60-01
J-28.70-01
J-29.10-00
J-29.15-00
J-29.16-01
J-40.10-03
J-40.20-01
J-40.30-03
J-40.35-01
J-40.36-01
J-40.37-01
J-40.38-01
J-40.39-00
J-40.40-00
J-50.10-00
J-50.11-00
J-50.12-00
J-50.15-00
J-50.16-01
J-50.20-00
J-50.25-00
J-50.30-00
J-60.05-00
J-60.11-00
J-60.12-00
J-60.13-00
J-60.14-00

Plan Title

Publication Approval Date

Type 1 Signal Standard Electrical Details


Ramp Meter Signal Standard Details
Ramp Meter Signal Standard Electrical Details
Signal Standard Foundation Plan
Signal Standard Foundation Placements
Type 4 and 5 Strain Pole Foundation
Type 4 and 5 Strain Pole Standard
Steel Light Standard
Steel Light Standard Placement (Slip Base)
Steel Light Standard Placement (Fixed Base)
Steel Light Standard Placement Miscellaneous
Steel Light Standard Foundation Types A & B
Steel Light Standard Base Mounting
Steel Light Standard Anchor/Slip Plate for Slip Base
Steel Light Std. Elbow Mounting on Bridge & Retaining
Wall
Steel Light Standard Pole Base and Hand Hole Details
Steel Light Standard Barrier Mounted Base
Steel Light Standard Wiring Details
Camera Pole Foundation Details
Camera Pole Standard
Camera Pole Standard Details
Locking Lid Standard Duty Junction Box Types 1 & 2
Heavy Duty Junction Box Types 4, 5 & 6
Locking Lid Standard Duty Junction Box Type 8
Sign Post-Mounted Junction Box
Nema 4X Non-Adjustable Junction Box
Nema 3R Adjustable Flush Mounted Junction Box
Top Entry Nema 4x Surface-Mounted Junction Box
Front Entry Nema 4X Surface Mount Junction Box
Nema 4X Junction Box in Sidewalk
Type 1 Induction Loop
Type 2 Induction Loop
Type 3 Induction Loop
Induction Loop Details
Preformed Loop Detail in New Bridge Deck
Permanent Traffic Recorder Installations
Weigh-In Motion Site Installation Details
Permanent Traffic Recorder & Weigh-In-Motion Details
Typical Grounding Details
Conduit Installation in Traffic Barrier on Retaining Wall
Conduit Installation in Single Slope Conc. Barrier (Dual
Face)
Stainless Steel Channel
Stainless Steel Channel Mounting Details on Column or
Pole

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

6/10/13
6/10/13
6/10/13
3/15/12
5/17/12
3/15/12
3/15/12
5/11/11
8/7/07
8/7/07
12/2/08
6/27/11
10/14/09
8/7/07
6/27/11
6/2/11
6/2/11
5/11/11
6/27/11
6/27/11
6/20/13
5/20/13
5/17/12
5/20/13
5/29/13
5/20/13
5/20/13
5/20/13
5/20/13
5/20/13
6/3/11
6/3/11
6/3/11
6/3/11
3/22/13
6/3/11
6/3/11
6/3/11
6/16/11
5/20/13
5/20/13

3 Sheets

2 Sheets
2 Sheets

2 Sheets

2 Sheets
2 Sheets
2 Sheets
2 Sheets
3 Sheets
2 Sheets

2 Sheets
3 Sheets
3 Sheets
2 Sheets
3 Sheets
2 Sheets
3 Sheets
4 Sheets
2 Sheets

6/16/10
6/16/10

Page 11

Contents
Plan No.

Plan Title

J-75.10-01
J-75.20-00
J-75.30-01
J-75.40-00
J-75.45-00
J-90.10-01
J-90.20-01

Section K

Temporary Channelization
Class A Construction Signing Installation
Type 3 Barricade
Alternative Temporary Conc. Barrier (F-Shape)
Temporary Conc. Barrier Anchoring
Temporary Conc. Barrier Anchoring ~ Narrow

5/11/11
10/14/09
10/14/09
6/27/11
6/27/11

2 Sheets
2 Sheets

2/15/07
2/21/07
12/20/06
2/21/07
2/21/07
2/21/07

2 Sheets

Wire Fence Types 1 & 2, and Wire Gates


Chain Link Fence Types 3 and 4
Chain Link Gate
Glare Screen Type 1 Design A
Glare Screen Type 1 Design B
Glare Screen Type 2 (Chain Link with Slats)
Access Control Gate
Access Control Double Gate

6/21/12
6/21/12
6/16/11
6/21/12
6/16/11
6/21/12
5/21/08
5/21/08

2 Sheets
2 Sheets
2 Sheets
2 Sheets

Roadway Delineation

M-1.20-02
M-1.40-02
M-1.60-02
M-1.80-03
M-2.20-02
M-3.10-03
M-3.20-02
M-3.30-03
M-3.40-03
M-3.50-02
M-5.10-02
M-7.50-01
M-9.50-01
M-9.60-00
M-11.10-01
M-15.10-01

Page 12

2/10/09

Fence and Glare Screen

L-10.10-02
L-20.10-02
L-30.10-01
L-40.10-02
L-40.15-01
L-40.20-02
L-70.10-01
L-70.20-01

Section M

5/11/11

Work Zone Traffic Control

K-70.20-00
K-80.10-00
K-80.20-00
K-80.30-00
K-80.35-00
K-80.37-00

Section L

Publication Approval Date

Signal Head Mounting Details~Pole and Post Top


Mountings
Signal Head Mounting Details Mast Arm and Span Wire
Mountings
Miscellaneous Signal Details
Overhead Sign Electrical Details (Monotube Structure)
Overhead Sign Electrical Details (Truss Structure)
Pull Box
Cable Vault

Ramp Channelization Single Lane


Ramp Channelization Two Lane
Ramp Channelization Collector Distributor Road
Ramp Channelization Parallel On & Weaving Section
Gore Area Marking Layouts
Left Turn Channelization
Left Turn Channelization: Reduced Tapers
Left Turn Channelization: Tee Intersection and
Back-to-back Turn Lanes
Two-way Left-Turn and Median Channelization
Double Left Turn Channelization
Right-Turn Channelization
High Occupancy Vehicle (HOV) Lane Symbol Layout
Bicycle Lane Symbol Layout
Shared - Use Path Markings
Railroad Crossing Layout
Crosswalk Layout

6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
6/3/11
1/30/07
1/30/07
2/10/09
1/30/07
2/6/07

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Contents
Plan No.

M-17.10-02
M-20.10-02
M-20.20-01
M-20.30-02

M-20.40-02
M-20.50-02
M-24.20-01
M-24.40-01
M-24.50-00
M-24.60-03
M-40.10-02
M-40.20-00
M-40.30-00
M-40.40-00
M-40.50-00
M-40.60-00
M-60.10-01
M-60.20-02
M-65.10-02
M-80.10-01
M-80.20-00
M-80.30-00

Plan Title

Parking Space Layouts


Longitudinal Marking Patterns
Profiled and Embossed Plastic Lines
Longitudinal Marking Supplement with Raised Pavement
Markers
Raised Pavement Markers (RPM's)
Longitudinal Marking Supplement with RPM's ~ Turn
Lanes
Longitudinal Marking Substitution with RPM's
Symbol Markings Traffic Arrows for High Speed
Roadways
Symbol Markings Traffic Arrows for Low Speed
Roadways
Roundabout Traffic Arrows
Symbol Markings: Miscellaneous
Guide Posts and Barrier Delineators
Guide Post Placement Interchanges
Guide Post Placement Grade Intersections
Guide Post Placement Horizontal Curves
Guide Post Placement Bridges
Guide Post Placement Miscellaneous
Shoulder Rumble Strip Type 1 for Divided Highways
Shoulder Rumble Strip, Types 2, 3, and 4,
for Undivided Highways
CenterLine Rumble Strip
Traffic Letter and Numeral Applications
Traffic Letters and Numerals (High Speed Roadways)
Traffic Letters and Numerals (Low Speed Roadways)

Standard Plans for Road, Bridge, and Municipal Construction


Effective August 5, 2013

Publication Approval Date

7/3/08
6/3/11
1/30/07
10/14/09

6/3/11

2 Sheets

6/3/11
5/31/06

3 Sheets

5/31/06

2 Sheets

6/16/11
5/11/11
5/11/11
10/12/07
9/20/07
9/20/07
9/20/07
9/20/07
6/3/11
6/27/11
5/11/11
6/3/11
6/10/08
6/10/08

2 Sheets

4 Sheets
2 Sheets
2 Sheets
2 Sheets

Page 13

J:

(.)

(.)

LINE DESIGNATION

..t::.

:iii

IN

<X:

:>-:

N
UJ

LINE STATIONING

..t::.
U1

HUNDRED FOOT
INCREMENTS

Ill

I~

Cl

DISTANCE FROM
(40.2 FEET)

<t

l>

.......
0
.......

U1
N

C)

"'U

LINE DESIGNATION

CUT TO BACK OF
DITCH (2.2 FEET)

U1

DISTANCE FROM <t


TO CATCH (BACK OF
DITCH) (25. 7 FEET)

~
N
LINE STATIONING

1--.~

HUNDRED FOOT
INCREMENTS

.......

~
A

CONTROL POINT

LINE DESIGNATION

0)

LINE STATIONING

CD

SIDE SLOPE RATIO


(4H:1V)

HUNDRED FOOT
INCREMENTS

BACK OF DITCH

FRONT

BACK

ALIGNMENT STAKE
SLOPE STAKE

STAKE EVERY 100 FEET ON TANGENTS,


EVERY 25 FEET ON CURVES

FRONT

BACK

CLEARING/GRUBBING (C&G) LATH


STAKE AT EACH FULL STATION,
100 FEET ON TANGENTS,
EVERY 25 FEET ON CURVES.
NO HUB NECESSARY.

@
"'Tl

IN

""'
n
N

IN

~
U1

{:

.........

~
A
0

FRONT

OFFSET FROM
SLOPE STAKE
CATCH (10 FEET)
FILL AT RP STAKE
(1.2 FEET)
CUT AT CATCH POINT
(BACK OF DITCH)
DISTANCE FROM <t
TO CATCH POINT

LINE DESIGNATION

(J)
ST

0)

CD

LINE STATIONING
HUNDRED FOOT
INCREMENTS

n
N
11.0

""'
N

-J

10'

OFFSET FROM
SLOPE STAKE
CATCH (7 FEET)
CUT AT ST
STAKE (2.9 FEET)
DISTANCE FROM~
(27.6 FEET)

n
N

IN

~
UJ

ll11

~
.......

~
CD
+

SIDE SLOPE RATIO


(4H:1V)

CUT AT CATCH POINT


(2.2 FEET)

DISTANCE FROM <t


TO CATCH (BACK OF
DITCH) (23.5 FEET)

IO
0
........

&

1-

SIDE SLOPE RATIO


(3H:1V)

LINE STATIONING

HUNDRED FOOT
INCREMENTS

DAYLIGHT CATCH
(CUT 0.0 FEET)

.......
0)

IN

FILL (0.1 FEET)


SIDE SLOPE TO
A2% ROADWAY
SLOPE (50H:1V)
~ISTANCE FROM C
(16.2 FEET)

BACK OF DITCH

BACK

LATH FOR SLOPE REFERENCES

SURVEY STAKES
FRONT

BACK

SLOPETREATMENT(ST)STAKE
FOR CUT SECTIONS

DAYLIGHT (D/L) STAKE

STANDARD PLAN A-10.10-00


SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


- .----::s=TAT=E=oE=SIG=N=EN=GIN=EE=R--...

08-07-07
DATE

fJ'I Washington State Department of Transportation

"'Tl
(JJ

~
N
00

"'-

FILL FROM CATCH POINT


TO BEGINNING OF SECOND
SLOPE (3.8 FEET)

n
0

~
N

SLOPE RATIO (2H:1V)

I ..to.

'-...
..t::.

FILL TO SUBGRADE
SHOULDER (2.25 FEET)

00

.......

..!::>

"'N
OJ

A
OJ

STRUCTURE NOTE REFERENCE

..t::.

PLAN SHEET NUMBER (4)


STRUCTURE NOTE NUMBER
(15)

@
"'Tl

I""'

"'Tl

DITCH CUT TO
BOTTOM OF DITCH
(0.60 FEET)
DISTANCE FROM
CATCH POl NT TO
BOTTOM OF DITCH
(2.4 FEET)

.......
U"1

.......

1-

OFFSET TO CENTER
OF BASE (10 FEET)

FILL TO TOP OF
CONCRETE BASE
(1.1 FEET TO TOP
OF FOUNDATION)

"*

(JJ

'-...
n

-I

.......

SIDE SLOPE RATIO


(4H:1V)

..t::.

DITCH SECTION ALIGNMENT


STATIONING

I~

SLOPE RATIO (4H:1V)

.......

"'Tl

BACK

HUNDRED FOOT
INCREMENTS

..t::.

I~

DISTANCE FROM~ TO CATCH


POINT (28.7 FEET)

FRONT

LINE DESIGNATION
AND STATIONING

fTl

-u

z
0
z

-J

LUMINAIRE NUMBER (23)

c
:s:::

FRONT

BACK

STAKE FOR FOUNDATION OF LUMINAIRES,


SIGNALS OR SIGN STRUCTURES

STAKE FOR DITCH CONSTRUCTION

COMPOUND SLOPE LATH

FILL TO SUBGRADE
(0.35 FEET)

I~

@
I~

C>

~
0

1;:::

"'Tl

STRUCTURE NOTE
REFERENCE

0
"'Tl

CUT TO FLOW LINE


(1.26 FEET)

en
I

(JJ

PLAN SHEET NUMBER (6)


STRUCTURE NOTE NUMBER (3)

I~

OFFSET (3 FEET)

OJ

FILL TO FINISH GRADE


(CURB ELEVATION) (0.73 FEET)

DRAINAGE ALIGNMENT
STATIONING

25' INCREMENTS

LINE DESIGNATION

FILL TO TOP AND


BACK EDGE OF
CURB (0.90 FEET)

..t::.

LINE STATIONING

OJ

HUNDRED FOOT
INCREMENTS

en

"'Tl

OJ

U"1

(JJ

.......

DISTANCE FROM

.......

OJ

n
.......

(/"1

OFFSET (10 FEET)

Cf. (14.3 FEET)

SLOPE RATIO (2H:1V)

FRONT

BACK
STAKE FOR DRAINAGE

FRONT

SURVEY STAKES

BACK

STAKE FOR CURB/GUTTER

STANDARD PLAN A-10.10-00


SHEET 2 OF 2 SHEETS

SLOPE LATH FOR


CURB SECTION

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

08-07-07
DATE

fJ'I Washington State Department of Transportation

1/32"

---j

r-

NOTES
3/64"

1;~7/1

1/8" DIAM. PUNCH MARK


OR CHISELED "X"
(TO BE PLACED AT
ACTUAL POINT)

@?)

rl/4"

~~IJ~IJ~@[M [M~~~,f~
:-~~~[L~ ~~~@}~~

2. The text in the shaded area (see TOP VIEW) shall be 3/16" high and will be stamped by WSDOT personnel prior to setting the cap. Only the assigned identification
letters and numbers are to be placed on the Brass Disc.

SECTION OF GROOVE
FOR 1/4" LETTERS

3. The hole shall be 32" minimum in depth or 6" below the deepest recorded frost line.
All loose material shall be removed from the bottom of the hole so that the concrete
is placed on firm undisturbed earth.

r~~~~~7/1

4. The top of the concrete shall be troweled smooth and the Brass Disc set in the
center with top flush and level. The top of the monument may be recessed or protruding, depending on conditions.

1/32"

1. The Brass Disc will be furnished by the State.

---j

1/32"

5. The Brass Disc shall be rotated so it can be read while the observer is facing north.
6. When the concrete is set, cover the entire monument with moist earth and leave for
three days.

SECTION OF GROOVE
FOR 3/16" LETTERS

7. To replace a Public Land Survey System (PLSS) corner, consult a licensed Professional Land Surveyor (PLS).

p [MJCQ)~~

10" MIN.

TYPE 1

TOP VIEW

TYPE2

BRASS DISC
5/8"

INSTALL FERROUS MATERIAL


SEGMENT - I.E., #4 IRON ROD
OR EQUIVALENT, 6" LONG MIN.

I>

SECTION VIEW

LEDGE ROCK, CONCRETE,


OR ASPHALT INSTALLATION

12" MIN.

I>
I>

..

3/4"

..

I>

___[ 1/8"

..

SECTION

I>

I>

I> . ..
.

..

I>
..

..

I> . ..

SURVEY MONUMENT
TYPES 1 AND 2
STANDARD PLAN A-1 0.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

14" MIN.

SIDE VIEW

Pasco Bakotich Ill

SECTION

SECTION VIEW

.....

STATE DESIGN ENGINEER

10-05-07
DATE

. . . Washington State Department of Transportation

GENERAL INSTALLATION

NOTES

RISER RING DIMENSIONS


A
(SIZE)

1 1/2"

2"

10 1/2" DIAM.

CONCRETE BASE

-~-~ ~

9 1/2" DIAM.

1"1.

f ~

~
I.

Co

.....'

1. Dimensions may vary according to manufacturer.

3"
I

.I

8" DIAM.

11

2. Base to be placed on a well compacted foundation.


3. Monument case to be installed by contractor.
4. See Standard Plan A-10.20 for Monument (brass
disc} type to place in 2" O.D. galvanized pipe.

~f

APPROXIMATE
WEIGHTS

9" DIAM.

SECTION

....1
....1

0
0

RISER RING

::::i

CASE

60 LBS

COVER

19 LBS

TOTAL

79 LBS

0:::
w

LL

_l__ 1"3116':

PLAN VIEW
1/4"

10" R.

SECTION OF LETTER
3 7/8" R.

3 3/4" R.

SECTION
t>

COVER

5 1/4" R.

4 3/4" R.

C')

......

t>

t>
t>

CONCRETE BASE

SOI~J~

:Z
----

t>

to

&>
'

I.

6"

MONUMENT CASE
AND COVER

4" R.

STANDARD PLAN A-1 0.30-00

GROUT

SHEET 1 OF 1 SHEET

2" O.D. GALVANIZED


STEEL PIPE - NOTE 4
5 3/4" R.

1"

SECTION

INSTALLATION

1 ..

SECTION

CASE

.I

APPROVED FOR PUBLICATION

ISOMETRIC

....

Pasco Bakotich Ill

------~S~~~TE~D~ES=IG~NE~NG~IN~E=ER~----

10-05-07
DATE

fJ'I Washington State Department of Transportation

L
....1
....1

c
c

NOTES

EXISTING GROUND LINE


(APPROXIMATELY LEVEL)\

1. Slope treatment shall be constructed simultaneously with the roadway excavation. Hand trimming
will not be required if satisfactory results are obtained with mechanical equipment.

::::i

ROADWAY EXCAVATION

0:::

LL

2.

---- -/~j!l}/}/lf!(ff;J?F-

Slope treatment is used to provide a transition between the existing ground and the cut slope.
The intended purpose is to eliminate the abrupt edge and give the area a more natural appearance.
The dimensions shown are approximate and can vary to achieve this purpose.

CUT SLOPE

TYPICAL SECTION

LEVEL GROUND LINE


CLASS A CLASS B
CUT
SLOPE

GROUND
LINE

(H: V)

(H: V)

L = 10.0'

L = 5.0'

+2: 1

0.5'

+3: 1

1.0'

0.5'

+4: 1

1.0'

0.5'

+6: 1

1.2'

0.8'

2.0'

1.0'

-6: 1

2.2'

1.0'

-4: 1

2.0'

1.0'

-3 : 1

3.0'

1.5'

+3: 1

0.5'

+4: 1

0.5'

0
0

+6: 1

1.2'

0.5'

1.5'

0.8'

-6: 1

2.2'

1.0'

-4: 1

2.0'

1.0'

-3 : 1

3.0'

1.5'

+6: 1

0.5'

1.0'

0.5'

-6: 1

1.2'

0.5'

-4: 1

1.5'

0.8'

ASCENDING GROUND LINE

r=xts''NG

---~

-- --

---~~

. 1:~t

CATCH POINT

1.5: 1
~

ROADWAY EXCAVATION

LEVEL

TYPICAL SECTION

ASCENDING GROUND LINE

2: 1

3: 1

LEVEL

LEVEL

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

MARK W. MAURER
CERTIFICATE NO. 000598

CATCH POINT

-3 : 1

2.0'

1.0'

0.5'

-6: 1

1.0'

0.5'

-4: 1

1.2'

0.5'

-3 : 1

1.5'

0.8'

0.5'

-6: 1

1.0'

0.5'

SHEET 1 OF 1 SHEET

-4: 1

1.2'

0.5'

APPROVED FOR PUBLICATION

-3 : 1

1.5'

0.8'

THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

, . . . . - - - - - - - ' NOTE:

DESCENDING GROUND LINE

LEVEL

ROADWAY EXCAVATION
4: 1

CUT SLOPE

LEVEL

SLOPE TREATMENT
STANDARD PLAN A-20.1 0-00

5: 1
TYPICAL SECTION

DESCENDING GROUND LINE

SLOPE TREATMENT NOT REQUIRED

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

08-31-07
DATE

State Department of Transportation

....1
....1

Cl
Cl

EQUAL SPACING

::::i

6' CENTERS MIN.


8' CENTERS MAX.

0::

"I

OUTER EXTREMITY
OF BRIDGE

-y

11..

I
I

OF BRIDGE

~I

i=

(.)

1-

0::

0..

0..

....1

en

I
I

~
(

DUMMY JOINT
(TYP.)

EXT END SLOPE PROTECTION

I---- 6" BEYOND OUTER EXTREMITY

\_

SECTION

EXISTING SOIL

PLACED
~6NEUMATICALLY
R CAST-IN-PLACE

c EMENT CONCRETE

PNEUMATICALLY PLACED
OR CAST-IN-PLACE
CEMENT CONCRETE

EMBANKMENT
SLOPE

FOOTING

PLAN

'fZ':
\__ EXISTING SOIL

SECTION

PNEUMATICALLY PLACED
OR CAST-IN-PLACE
CEMENT CONCRETE

10 GAGE 6" K 6" WIRE MESH REINFORCEMENT CENTERED IN CONCRETE.


(SEE STD. SPEC. 9-07.7)

2 112"

BOTTOM EDGE OF SLOPE PROTECTION


FOLLOWS BOTTOM OF DITCH

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

EDGE OF SHOULDER

ANDRA L.SALISBURY
CERTIFICATE NO. 000860
THIS PLAN fS NOT A LEGAL ENGINEERfNG DOCUMENT BUT AN ELECTRONIC DUPUCA 1E. THE ORIGINAL.. SIGNED BY THE ENGINEER AND

. - - - - - - - - - - ' NOTE:

APPROVED FOR PUB/..JCA nON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPART-

MENT OF TRANSPORTA nON. A COPY MAY BE OBTAINED UPON REQUEST.

CONCRETE SLOPE
PROTECTION

FOOTING

STANDARD PLAN A-30.10-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

TYPICAL SECTION
(SHOWN ON LOWER ROADWAY)

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

11-B-07
DATE

Washington State Department of Transportation

LATERAL EXTREMITY
OF BRIDGE -

TOP OF SLOPE
UNDER BRIDGE

2-/

NOTES

~
f!J
.....

.....

1. The design and shape of the semi-open concrete


masonry unit shown is only one example of the
products that may be used.

TOP OF
ROADWAY

2. The Curb Section shall be used


only when the lower roadway cross section
requires a curb.

MASONRY UNIT
(TYP.)

FOOTING

2' - 6" OR DEPTH OF FOOTING PLUS


LENGTH OF ONE MASONRY UNIT

PLAN

MASONRY UNIT PLACEMENT


ON SKEWED BRIDGE

MATCH SHOULDER
CROSS SLOPE

5'- 0" MIN.

EDGE OF SHOULDER
TOP OF
ROADWAY

...J
...J

0
0

ISOMETRIC VIEW

:J

0::

Co

u...

....'

MASONRY UNIT
EMBANKMENT SLOPE

FOOTING

TYPICAL SECTION
VOID (TYP.)

SECTION

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

2' - 6" OR DEPTH OF FOOTING PLUS


LENGTH OF ONE MASONRY UNIT

ANORA L.SALISBURY
CERTIFICATE NO. 000860

MATCH SIDEWALK
CROSS SLOPE

SIDEWALK 6' 0" MIN.


(SEE CONTRACT)

NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

TOP OF
ROADWAY

r-r----r-..,.--r----,--,--,--r---,___j_

I I I II I II II

,------_J

3 18
' "

LI-~-L-L~2-3-~~8. ~...J_~~~I---r

SEMI-OPEN
CONCRETE MASONRY
SLOPE PROTECTION
STANDARD PLAN A-30.15-00
SHEET 1 OF 1 SHEET

FOOTING

MASONRY UNIT DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

(SEE NOTE 1)

STATE DESIGN ENGINEER

....
fJ'I
Washington

SECTION WITH SIDEWALK

11-8-07
DATE

State Department o Transportation

MAXIMUM LENGTH OF TOP HORIZONTAL SUPPORT ROPE = B

....1
....1

4" GALVANIZED, WELDLESS STEEL RING


WITH A MINIMUM SINGLE PULL WORKING
LIMIT OF 10,000 LBS. (TYP.)- AT ALL ENDS
OF HORIZONTAL SUPPORT ROPES

LlJ

Cl
Cl

MAXIMUM ANCHOR SPACING =A


(SEE NOTE 1)

::::i

TO BE DETERMINED
BY ENGINEER

0::
LlJ
LL.

3/4" DIAM. 6x19 IWRC


GALVANIZED WIRE ROPE

.............. ....-

4" GALVANIZED, WELDLESS STEEL RING


WITH A MINIMUM SINGLE PULL WORKING
LIMIT OF 10,000 LBS. (TYP.)- AT ALL ENDS
OF HORIZONTAL SUPPORT ROPES

WIRE ROPE CLIPS {

~---------------------------/-

U-Section of wire rope clip must be applied to the dead


end, and saddle of wire rope clip must be applied to the
live end of the rope as shown.

~ All wire rope loops shall include a standard weight thimble.

- rI

0'- 100'
100'- 200'
200'- 300'

50'
35'
20'

MAXIMUM LENGTH - TOP


HORIZONTAL SUPPORT ROPE
(B)

3" FABRIC
OVERLAP

H
50'
100'
200'
300'

9 GAGE (MIN.) GALVANIZED


LACING WIRE, WOVEN
THROUGH EACH CELL

B
400'
200'
100'
75'

THIMBLE (SEE NOTE 4)


WIRE ROPE CLIP (TYP.)

_j

Hexagonal mesh must meet minimum requirements of


ASTM A975 for gabions.

i
i
i
i

SECTION VIEW

3" SPACING

SEAM

Maximum anchor spacing (A) for debris and impact loads


required as per table for a minimum allowable anchor
capacity of 20,000 lbs. Systems subjected to snow
loads may require narrower maximum spacing.

MAXIMUM ANCHOR SPACING


(A)

ELEVATION

SEAM

I--

NOTES

i
i
i
i
i

_ L __ _ _

3/4" DIAM. 6x19 IWRC GALVANIZED TOP


HORIZONTAL SUPPORT ROPE

8 x10 TYPE DOUBLE TWISTED


HEXAGONAL WIRE MESH
FABRIC. (SEE NOTE 2)

---j

SLOPE PROTECTION ANCHOR


- SEE STANDARD PLAN A-30.35.

3" FABRIC
OVERLAP

.~

i
i
i
i
i
i

9 GAGE (MIN.) GALVANIZED LACING WIRE OR


11 GAGE HIGH TENSILE STEEL FASTENERS
EVERY CELL ( ::::: 3" SPACING)

SEAM

.~

.~

DEAD END
(SEE NOTE 3)

WIRE MESH SLOPE


PROTECTION

11 GAGE HIGH TENSILE


STEEL FASTENERS

OVERLAPPED SEAM
WITH FASTENERS

OVERLAPPED SEAM
WITH LACING

STANDARD PLAN A-30.30-01


LIVE END
(SEE NOTE 3)

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SEAM ALTERNATIVES
WIRE ROPE DETAIL
DISTANCES X,Y,Z AND TORQUE TO COMPLY WITH MANUFACTURER'S SPECIFICATIONS

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

GROUND LINE

NOTES

....1
....1

3/4" DIAM. 6 X 19 IWRC


GALVANIZED WIRE ROPE

0
0

3/4" DIAM. 6 X 19 IWRC


GALVANIZED WIRE ROPE

SUGGESTED MINIMUM DEPTH

::::i

0::

::;..:
m

THIMBLE
#3 BAR (TYP.) - FOUR REQUIRED

MINIMUM ALLOWABLE ANCHOR


CAPACITY SHALL BE 20,000 LBS.

FERRULE

LL.

WIRE ROPE
CLIP (TYP.)

....

#3 BAR (TYP.) FOUR REQUIRED

3/4" DIAM. 6 x 19 IWRC


GALVANIZED WIRE ROPE

REINFORCED CONCRETE POST 8" SQUARE OR 9" DIAM. x 60" MIN.,


PLACE WIRE ROPE AT CENTER OF POST

WIRE ROPE CLIP (TYP.)


CEMENTGROUT////

REINFORCED CONCRETE POST12" X 12" X 66", PLACE WIRE ROPE


AT CENTER OF POST

FERRULE

~ .!~ ~

TYPE4

TYPE 1

MIN.

3/4" WIRE ROPE

DEADMAN

(FOR USE IN ROCK OR SOIL)

(FOR USE IN SOIL)

GROUND LINE

3/4" DIAM. 6 X 19 IWRC


GALVANIZED WIRE ROPE

,/ /~

FERRULE
VIJIRE ROPE
CLIP (TYP.)

THIMBLE

MANTA RAY@

3/4" DIAM. 6 X 19 IWRC


GALVANIZED WIRE ROPE

3/4" DIAM. 6 x 19 IWRC


GALVANIZED WIRE ROPE

..

CEMENT GROUT

TYPES
14"

10'- 0" MIN.

1-1--~+~-------___cc_:~-------j
MIN.

#3 BAR (TYP.) - __)


FOUR REQUIRED

TYPE2

MECHANICAL ANCHOR
REINFORCED CONCRETE POST
(TYP.) - 12" X 12" X 66", PLACE
WIRE ROPE AT CENTER OF POST

(FOR USE IN SOIL)

DEADMAN
(FOR USE IN SOIL)
HEX NUT
STEEL BEARING PLATES
3/4" DIAM. 6 X 19 IWRC
GALVANIZED WIRE ROPE

THIMBLE

FERRULE
3/4" DIAM. 6 X 19 IWRC
GALVANIZED WIRE ROPE

THIMBLE
3/4" DIAM. 6 x 19 IWRC
GALVANIZED WIRE ROPE
COUPLER

WIRE ROPE CLIP


(TYP.)

WIRE ROPE CLIP


(TYP.)

CEMENT GROUT

HOLLOW CORE THREADED BAR


SACRIFICIAL DRILL BIT

SLOPE PROTECTION
ANCHORS
STANDARD PLAN A-30.35-00

A\. N0.8 GRADE 60 DEFORMED

SHEET 1 OF 1 SHEET

"'ll' STEEL THREADED BAR

APPROVED FOR PUBLICATION

CEMENT GROUT

TYPE3

TYPES

DRILLABLE GROUTABLE

DEFORMED STEEL THREADED BAR

(FOR USE IN ROCK)

(FOR USE IN ROCK)

Pasco Bakotich Ill

......
VI

-----,S::::TA::::TE:-:D::=ES::::IG""N-:::EN""G""INE=E:=-R- - -

10-12-07
DATE

Washington State Department of Transportation

NOTES
DOWEL BARS SPACED@ 1'- 0" ON CENTER, AT TRANSVERSE JOINT

1'- 0"

1'- 0"

TOP SPACER BAR (TYP.)


0.362" DIAM.
2 PER ASSEMBLY
(WELD TO LEG CHAIRS)

WIRE LEG (TYP.)


-SEENOTE1 \
'

1. The "U" shape or "V'' shape are both acceptable.

1 1/2"
(TYP.)

2. Wire sizes shown are minimum required.


3. All wire intersections are to be welded.

1-

1-

0::::::!!:

ow

~--~
~D...
Ow
....,1...Jw
<Co:::
~(.)

oz

::JO

1-(.)

au..
zo
Ow

....1(!)

I II

.II

'

lb

DOWEL
BAR-----....._
(TYP.)

w
0::: :::!!:

4.

Basket must be firmly attached to existing or new base.

1- ~
~D...
Ow
...., 1-

5.

Dowels and Tie Bars shall be held firmly in the above


welded assembly.

6.

Do not clip Spreader Wires.

ow
....1

<( 0:::

~(.)

'

::JO

1-(.)

1 II

I II

w
SPREADER WIRES (TYP.)
- 0.117" DIAM.
3 PER ASSEMBLY
(WELD TO TOP SPACER BARS)

au..
zo

II

Ow
....1(!)

_....J

BOTTOM SPACER BAR (TYP.)


- 0.362" DIAM.
2 PER ASSEMBLY
(WELD TO LEG CHAIRS)

DOWEL BAR BASKET

TOP
SPACER
BAR

DOWEL BAR
- 1/2" R. PLUS 1/8"

TOP
SPACER
BAR

DOWEL BAR
- 1/2" R. PLUS 1/8"

PLAN VIEW
"U" SHAPE ASSEMBLY SHOWN

WIRE LEG - - -

BOTTOM
SPACER
BAR
"U"SHAPE
1-

PAVEMENT LANE WIDTH

1'- 0"
SPREADER WIRE (TYP.)

TOP SPACER BARS

Wcn
:i!:cn

w w

~ ~
D...(.)
~

DETAIL

BOTTOM
SPACER
BAR

''V"SHAPE

WIRE LEG DETAILS

:c

...... 1-

WIRE LEG (TYP.)


-SEE NOTE 1

BOTTOM SPACER BARS

BASE

SECTION

ELEVATION VIEW
"U" SHAPE ASSEMBLY SHOWN

1'- 6"
1 1/2" (TYP.)

WELD ALTERNATE ENDS


OF DOWEL BARS (TYP.)

1-

zcn

WIRE LEG (TYP.)

DOWEL BAR BASKETS

W(J)

:::!!: w
w z

>
~
<((.)

BASE

STANDARD PLAN A-40.00-00

D...-

:I:
1-

SHEET 1 OF 1 SHEET
ISOMETRIC VIEW

BOTTOM SPACER
BAR (TYP.)

SECTION

"U" SHAPE ASSEMBLY SHOWN

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

08-11-09
DATE

Washington State Department of Transportation

....1
....1

FINISH OUTER EDGE OF PCCP


SHOULDER WITH 1/2" RADIUS

15'- 0" (TYP.}

TRANSVERSE CONTRACTION OR
CONSTRUCTION JOINT (TYP.}
(SEE SECTION VIEWS}

0
0

::::i

z
a::

SAWED GROOVE WIDTH 3/16" MIN., 5/16" MAX.


OVER MIDPOINT OF BAR
SEE STD. SPEC. 5-05.3(8)8

SAWED GROOVE WIDTH 3/16" MIN., 5/16" MAX .


OVER MIDPOINT OF BAR
SEE STD. SPEC. 5-05.3(8)8

. Dt4

LL.

/).

,.

b
'

.
"'

-------

PCCP SHOULDER IF REQUIRED

~
I>

'

. ,.

!!>.

"'

I>.,.

/!>.

3N

[>.

[>

/!>

I -

LONGITUDINAL CONTRACTION OR
CONSTRUCTION JOINTS (TYP.}
(SEE SECTION VIEWS}

TIE BAR#5 BAR X 30" LONG


ON 36" CENTERS

SECTION VIEW

LONGITUDINAL CONTRACTION JOINT

DOWEL BAR1 1/2" DIAM. x 18" LONG


ON 12" CENTERS

SECTION VIEW

TRANSVERSE CONTRACTION JOINT

I - - I
I

#5 TIE BAR - 30" LONG


ON 36" CENTERS
TYPICAL ALL LANES

I - - I
I -

I -

DOWEL BARS1 1/2" DIAM. x 18" LONG


ON 12" CENTERS
TYPICAL ALL LANES UNLESS
NOTED IN THE PLANS

[.

/!>

PCCP

[>

J[

/!>.

------[>
[>,

[>.

/!>.

/!>.

/!>.

/!>.

/!> .

/!>.

TIE BAR#5 BAR X 30" LONG


ON 36" CENTERS

15"
LONGITUDINAL JOINT
(SEE SECTION VIEW}
FINISH OUTER EDGE OF PCCP
SHOULDER WITH 1/2" RADIUS

[>

HMA SHOULDER IF REQUIRED

PLAN VIEW

SAWED GROOVE WIDTH 3/16" MIN., 5/16" MAX.


DEPTH 1" MIN.
SEE STD. SPEC. 5-05.3(8)C

SAWED GROOVE WIDTH 3/16" MIN., 5/16" MAX.


DEPTH 1" MIN.
SEE STD. SPEC. 5-05.3(8)C

DRILL AND GROUT WHEN


WIDENING EXISTING
PAVEMENT WITH PCCP

9"

DOWEL BAR1 1/2" DIAM. X 18" LONG


ON 12" CENTERS

SECTION VIEW

SECTION VIEW

PCCPTO PCCP
LONGITUDINAL CONSTRUCTION JOINT

TRANSVERSE CONSTRUCTION JOINT

CONSTRUCTION JOINT
SLAB
THICKNESS
(D)

12"

5"

D/2- 1"

'

"V

'

2'- 0"

#5 BAR- 18" LONG


@ 12" SPACING

HMA TRANSITION
DETAIL

12"

15"

1.25

NO DOWEL BARS REQUIRED

EXISTING BRIDGE
APPROACH SLAB
D

USE ON GRANDULAR BASES ONLY


NO TAPER REQUIRED ON ASPHALT BASES

3" TO 4"

ELEVATION VIEW

DEPTH OF
PCCP (D)

SAWED GROOVE WIDTH 3/16" MIN., 5/16" MAX.


DEPTH 1" MIN.
SEE STD. SPEC. 5-04.3(12}8

HMA

[>

EXISTING PCCP
t>. ,.

HMA
. i:>

/!>.
[>

/!>.

/!>

/!>.

CEMENT CONCRETE
PAVEMENT ~OINTS

SECTION VIEW

PCCPTO HMA
LONGITUDINAL JOINT

STANDARD PLAN A-40.10-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ELEVATION VIEW

EXISTING APPROACH SLAB TRANSITION


DETAIL

Pasco Bakotich Ill

.....
fll

-----,s=rA=TE=-:D=E=SIG""N""EN:-c:Gc:ciN=EE"'"R---

06-02-11
DATE

Washington State Department of Transportation

RECTANGULAR FRAME
(COMBINATION INLET SHOWN)
FACE OF
CURB

FACE OF
CURB

FACE OF CURB
ISOLATION
PAD

....1
....1

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

FACE OF CURB

0
0

::::i

0:::

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

LL.

PAVEMENT JOINT

CONDITION B

CONDITION A

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

PAVEMENT JOINT

'
'
'

CONDITION C

EDGE OF SHOULDER

'
'

(SHOULDER USE ONLY)

TIE BAR-# 5 BAR,


30" LONG
SPACING 6" O.C.

PAVEMENT
JOINT (TYP.)

CONDITION D

CIRCULAR
FRAME
LESS
THAN
4'- 0"

RECTANGULAR FRAME

CIRCULAR
FRAME

4' - 0" OR MORE


TIE BAR# 5 BAR, 30" LONG
SPACING 6" O.C.

TIE BAR - # 5 BAR, 30" LONG


SPACING = 6" O.C.

I
ISOLATION JOINT3/4" PREMOLDED
JOINT FILLER

PAVEMENT
JOINT

FACE OF CURB

'

:--...,

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

USUAL

c__ JOINT

TRACK

FACE OF
CURB

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

ADJUSTED PAVEMENT
JOINT

TIE BAR# 5 BAR, 30" LONG


SPACING = 6" O.C.

PAVEMENT
JOINT (TYP.)

CONDITION H
RECTANGULAR
FRAME
PAVEMENT JOINT (TYP.)

NOTE

CONDITION F

CONDITIONE

CONDITION G

ALL CONDITIONS ARE SHOWN IN PLAN VIEW.

~~

ow
=' ....1
'rC:::

PAVEMENT JOINT (TYP.)

------------------------ _'?------------------ -~-~4'- 0"


OR LESS

CIRCULAR
FRAME

USUAL
c__ JOINT
TRACK

USUAL JOINT
TRACK (TYP.)

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

__s;

PCC PAVEMENT
ISOLATION ~OINTS
CIRCULAR
FRAME

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

4'- 0"
OR MORE

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

CIRCULAR
FRAME

STANDARD PLAN A-40.15-00


SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ADJUSTED PAVEMENT
JOINT (TYP.)

CONDITION I

PAVEMENT JOINT (TYP.)

Pasco Bakotich Ill


CONDITIONJ

VI
.....

08-11-09

STATE DESIGN ENGINEER

DATE

Washington State Department o Transportation

CONDITIONC

....1
....1

CONDITION A

CONDITION B

CONDITIONE

CONDITION D

----~-----------+----------~----------+-----------~---------+----------~----------+-----------~--------~---------1-----------r----------1-----------r---------~-----------+----------~----

CONDITION I

0:::

w
u.

CONDITIONJ

z----~-----------+----------~----------+-----------~---------+----------~----------+-----------~--------~---------1----------~----------~

CONDITIONG

CONDITION H
'I

DRILL A 2" DIAM.


FULL-DEPTH HOLE,
FILL WITH JOINT SEALER

PAVEMENT JOINT (TYP.)

PLAN
PAVEMENT JOINT (TYP.)

TYPICAL APPLICATIONS
T- JOINT DETAIL
TYPICAL ISOLATION JOINT GUIDELINES
CONDITION

FEATURE

EDGES, FLANGES OR
LIPS IN THE
PAVEMENT SECTION

CONTINUOUS VERTICAL
FACE THROUGH THE
PAVEMENT SECTION

DISTANCE
FROM NEAREST
TRANSVERSE JOINT

CATCH BASIN OR
COMBINATION GRATE

USE

----

----

CATCH BASIN OR
COMBINATION GRATE

USE

----

----

CATCH BASIN OR
COMBINATION GRATE

USE

----

> 4 FT FROM JOINT

GRATE INLET,
CATCH BASIN OR
CONCRETE INLET*

----

USE

< 4 FT FROM JOINT

GRATE INLET,
CATCH BASIN OR
CONCRETE INLET*

----

USE

< 4 FT FROM JOINT

GRATE INLET,
CATCH BASIN OR
CONCRETE INLET*

----

USE

> 4 FT FROM JOINT

MANHOLE OR
CATCH BASIN TYPE 2

USE

----

----

MANHOLE OR
CATCH BASIN TYPE 2

USE

----

----

MANHOLE OR
CATCH BASIN TYPE 2

USE

--

< 4 FT FROM JOINT

MANHOLE OR
CATCH BASIN TYPE 2

USE

J
*

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

WITH RECTANGULAR GRATE CAST INTO ADJUSTMENT SECTION.

> 4 FT FROM JOINT

ISOLATION JOINT3/4" PREMOLDED


JOINT FILLER

CONTINUOUS VERTICAL
FACE THROUGH THE
PAVED SECTION
ISOLATION JOINT3/4" PREMOLDED
JOINT FILLER

t>
t>
t>

\7 .

PCC PAVEMENT
ISOLATION .JOINTS
SECTION

----

EDGES, FLANGES OR LIPS


IN PAVEMENT SECTION

STANDARD PLAN A-40.15-00


SHEET 2 OF 2 SHEETS

SECTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

08-11-09
DATE

Washington State Department of Transportation

~ SAWCUT
3/4" +/- 1/4"

~ SAWCUT

~ SAWCUT

1" +/- 1/4"'

~ SAWCUT

I
I

SEE NOTE 2

SEE NOTE 2

SEE NOTE 2

1/4" +/- 1/8"

SEE NOTE 2

I>

[>
NEWHMA

NEWHMA

J:

NEWHMA

NEWHMA

b::

I>

I-

I-

D.

b::

:>

I>

~
en

I>

[>

EXISTING
ASPHALT

[>

I>

CONCRETE '

I>

I>

I>

CONCRETE

CONCRETE

EXISTING
ASPHALT

EXISTING
ASPHALT

I>

I>

[>

CONCRETE

EXISTING
ASPHALT

I>

I>

I>

I>

I>

1>,

I>

I>

D.

[>
I>

I>

I>

[>

I>

I>

I>

DETAIL 1

DETAIL 2

DETAIL 3

DETAIL 4

JOINT SEAL AT END OF CONCRETE

JOINT SEAL AT END OF CONCRETE

CONCRETE ASPHALT BUTT JOINT

CONCRETE ASPHALT BUTT JOINT

1/2" JOINT SEAL

1" JOINT SEAL

1/2" JOINT SEAL

1" JOINT SEAL

..J
..J

0
0

NEWHMA
I>

{>

I>

(.)

I>

~
en

D.

[>

:>

(.)
I>

I>

NEWHMA

I>

I>

J:

::J

z
c:::
w

NOTES

11..

1. Use the 1/2" joint details for bridges with expansion length less than
100' and for bridges with L type abutments. Use the 1" joint details
for other applications. Use DETAIL 5 on steel trusses and timber
bridges with concrete deck panels.
CLEAN AND SEAL
(LEVEL WITH CONCRETE)
IN ACCORDANCE WITH
STANDARD SPEC.
SECTION 5-01.3(8)

~ SAWCUT AND

SEE NOTE 2

HMA

~ SAWCUT AND

CLEAN AND SEAL


(LEVEL WITH CONCRETE)
IN ACCORDANCE WITH
STANDARD SPEC.
SECTION 5-01.3(8)

EXISTING JOINT

I EXISTING JOINT

2. Sawcut shall be as described in Standard Specification 5-05.3(8)


and sealed in accordance with Standard Specification 5-05.3(8)B.

3. The contractor shall avoid sawing out concrete at all locations. For details
1 and 2, the construction tolerance to locate the saw cut is 1/4" (0 min.
to 1/2" max.) from the concrete.

SEE NOTE 2

1"

HMA

HMA

~JOINT

HMA

WATERPROOFING
MEMBRANE
(DECK SEAL)

WATERPROOFING
MEMBRANE
(DECK SEAL)

[>

D.

[>
I>

/)'

[>
I>

I>

CONCRETE

a.

CONCRETE

[>

I>

[>

D.

CONCRETE
I>

I>

I>

D.
CONCRETE

I>

I>

I>

I>
I>

[>
I>

CONCRETE

D.

[>

[>

[>

I>

D.

0
1-

:::>

~<(

en
I>

I>

I>

I>

I>

I>

CONCRETE

a.

[>

a.

D.

J:
1-

[>

[>

J:
1-

I>

I>

[>
I>

D.

I>

D.

[>

J:
1-

I>

[>

I>

I>

CLEAN AND SEAL IN ACCORDANCE WITH


STANDARD SPEC. SECTION 5-01.3(8)

I>

I>

I>

I>

[>

[>

I>

BRIDGE TRANSVERSE
.JOINT SEALS
STANDARD PLAN A-40.20-02
SHEET 1 OF 1 SHEET

FOAM BACKER ROD

FOAM BACKER ROD

APPROVED FOR PUBLICATION

FOAM BACKER ROD

DETAILS

DETAIL 6

DETAIL 7

BRIDGE TRANSVERSE JOINT SEAL

BRIDGE TRANSVERSE JOINT SEAL

CONCRETE OPEN JOINT

1/2" JOINT SEAL

1" JOINT SEAL

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

5129113
DATE

~ Washington State Department of Transportation

'I
- --l

BRIDGE

NOTES

25'- 0"

....1
....1

APPROACH SLAB

Cl
Cl

::::i

0::

LL.

CIJ
0::

::c

LONGITUDINAL JOINT
- WHEN REQUIRED
(SEE NOTE 2)

<(0::

zw
01z
CIJW

Cl

'

:eN

~@)

c...
c...

11

11

2 I AP5I'W#5

<(

~;

~:

11~--++-----1--- ;~

~(.)

c... =
xo

2. Longitudinal joints shall be placed on lane lines and shall be constructed and sealed in accordance with

@)

Standard Specification Section 5-05.3(8). Joints may be either a sawcut crack control joint or a construction joint. Sawcut joints shall terminate 1' - 0" before reaching edge of slab and must be saw cut
as soon as possible after placement of concrete.

(.)

ZCIJ

ment of a LONGITUDINAL CONSTRUCTION JOINT.

~------.
in

BACK OF
PAVEMENT SEAT

1. All edges of the approach slab shall have 1/2" radii except the longitudinal edge of the preceeding place-

~g
~g

::c

1Cl

:5:
III
::s
CIJ

(A) Approach slabs less than 40' wide -- no joint is required.


(B) Approach slabs wider than 40' -- one or more joints are required
to divide the slab into approximately 24' wide sections.

::c

(.)

<(

0
0::

3. The minimum lap splice of#5 is 2'- 0". W#s is 2'- 6". W#6 is 3'- 0". And #8 is 3'- 3". All lap splices
shall be stagged so that no more than 50% of rebar is spliced at the same location. Lap splices shall be
#6.
located within the middle half of the bridge approach slab. Optional splices are allowed for I AP41

c...
c...
<(

__ _l ___ _j ==1-~_l_

-=~T=o=P:~,1------------=IA~P=4=1=X7~#_6~@~1'_-_o"_M_AX ~.II.
__
. __

BOTTOM:

I AP3 I

2"UVP.J

TOP OF GRADE
APPROACH SLAB

#5 @ 9" MAX.

TOP OF GRADE
APPROACH SLAB

1/2" SAWCUT JOINT


3" SAWCUT DEPTH
TOP OF HMA ROADWAY

1/2" PREMOLDED
JOINT FILLER

SLEEVE WITH
POLYSTYRENE
OR PVC PIPE

PLAN

BRIDGE

ROADWAY

SUBGRADE
SAWCUT SHALL BE FILLED WITH HOT- POURED COMPONENT IN ACCORDANCE
WITH STANDARD SPECIFICATION SECTION 9-04.2(1) AND SEALED IN ACCORDANCE WITH STANDARD SPECIFICATION SECTION 5-05.3(8)8

2" CLR. (TYP.)

HMA ROADWAY JOINT DETAIL

BRIDGE APPROACH SLAB

TOP:

I AP4 I

#6

BOTTOM: I AP3 I #5

SEE SHEET 2 FOR


ANCHOR DETAILS

DOWEL BAR DETAIL FOR CEMENT


CONCRETE PAVEMENT

C\1
-o::
~__.

I AP2 I'W #5

CRACK CONTROL
JOINT

NU

IAP5I'W#5---+~t~~

~~~~~~~~~~~~o~\~~o~~0~
0~~~0~~
0 ~o~o~o~
0:::

....1

CRUSHED SURFACING BASE COURSE COMPACTED DEPTH OF 0.2' OR MATCH


DEPTH OF ROADWAY SECTION

C\1

FOR LOCAL AGENCY USE ONLY


SEE DOWEL BAR DETAIL
FOR CEMENT CONCRETE
PAVEMENT OR HMA ROADWAY
JOINT DETAIL

. . . . .

--------------------LONGITUDINAL
CRACK CONTROL JOINT

LONGITUDINAL SECTION

tl

VARIES

IAP21

9r:)_l_

w
c
1-

I AP71

:J
VARIES
IAP41

-I

= EPOXY COATED REINFORCING STEEL

w ~f

PRECEEDING PLACEMENT

1 1/2" CLR.
(TYP.)

BENDING DIAGRAM

c
6'- 0"

1,,

IAP8I

I AP3I#5

SEE NOTE 2

NEXT PLACEMENT

~ll

INSERT DOWELS PARALLEL TO CENTER LINE


ALONG TRANSVERSE CONSTRUCTION JOINT

1/8" R. - SEE NOTE 1

-I
w

BRIDGE APPROACH SLAB


STANDARD PLAN A-40.50-01

TOPOF

l_~ ABUTMENT

~rrAP9I
(ALL DIMENSIONS ARE OUT TO OUT)

SHEET 1 OF 2 SHEETS

2'- 0"
MIN. LAP

APPROVED FOR PUBLICATION

EDGE PRECEEDING PLACEMENT ONLY WITH 1/8" RADIUS

ALTERNATE LONGITUDINAL
JOINT DETAIL
SEE NOTE 2

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

BRIDGE

BRIDGE APPROACH SLAB

....1
....1

BRIDGE

SEE APPROACH EXPANSION


ANCHOR DETAILS

Cl
Cl

BRIDGE APPROACH SLAB


SEE L-TYPE ABUTMENT
PINNED ANCHOR DETAIL

EXPANSION JOINT (SEE PLANS) ~

::::i

.-+-..----~

0::

NOTE

LL.

SUPERSTRUCTURE

PAINT THE METAL COMPONENTS OF THE APPROACH EXPANSION ANCHOR


WITH ONE COAT OF INORGANIC ZINC PAINT CONFORMING TO EITHER
STANDARD SPECIFICATION SECTION 9-08.1(2)F OR BE GALVANIZED
IN ACCORDANCE WITH AASHTO M 232.

ABUTMENT

Cl

SUPERSTRUCTURE

ABUTMENT
LONGITUDAL SECTION

LONGITUDAL SECTION

SEMI-INTEGRAL TYPE ABUTMENT

L - TYPE ABUTMENT

BRIDGE
1/4" X 2 1/2"
SQUARE PLATE
WITH 2 NUTS

BRIDGE APPROACH SLAB

10" MIN.

BRIDGE
8" MIN.

SEE COMPRESSION
SEAL DETAIL

EMBEDMENT

BRIDGE APPROACH SLAB

EMBEDMENT

BRIDGE

SEE COMPRESSION
SEAL DETAIL

SEE ANCHOR
HEAD DETAIL

BRIDGE APPROACH SLAB

CONSTRUCTION JOINT
WITH CLASS II FINISH
SEE ANCHOR
HEAD DETAIL

co

PLACED IN ABUTMENT
(BARS MAY BE FIELD BENT)

I
3/4" DIAM. STOP TYPE COUPLER
WI MIN. TENSILE STRENGTH
OF 20,000 LBS

EXPANDED POLYSTYRENE
FULL LENGTH OF JOINT
BENEATH COMPRESSION SEAL

ANCHOR ROD SET W/ EPOXY RESIN TYPE IV


MEETING THE REQUIREMENTS OF
3/4" DIAM. x 1'- 3 1/2" ANCHOR ROD
STANDARD SPEC. SECTION 9-26
THREADED 3" MIN. ON END
AWAY FROM ANCHOR HEAD

:Y." DIAM. x 1'- 10" ANCHOR ROD

1" DIAM. X 1'- 0" LONG


POLYETHYLENE
OR PVC PIPE

1" DIAM. X 1'- 0" LONG


POLYETHYLENE
OR PVC PIPE

THREADED 8" MIN. ON END


AWAY FROM ANCHOR HEAD

EXPANDED POLYSTYRENE x FULL


LENGTH OF JOINT BENEATH
COMPRESSION SEAL

FOR LOCAL AGENCY USE ONLY

APPROACH EXPANSION ANCHOR - METHOD B

SEMI-INTEGRAL TYPE ONLY

SEMI-INTEGRAL TYPE ONLY

BRIDGE APPROACH SLAB

NORMAL TO
ct_ OF SEAL
ELASTOMETRIC COMPRESSION
SEAL, SEE "COMPRESSION SEAL
TABLE,"@ RIGHT

L- TYPE ABUTMENT PINNED ANCHOR DETAIL

PAVEMENT SEAT,
COVER WITH ONE LAYER 15#
ASP HALTIC BUILDING FELT

PAVEMENT SEATCOVER WITH ONE LAYER 15#


ASPHALTIC BUILDING FELT

APPROACH EXPANSION ANCHOR- METHOD A

BRIDGE

I AP9 I #5@ 12" CENTERS,

7/8" DIAM. x 8" MIN. HOLE

3/4" DIAM. x 10' ANCHOR ROD


FULLY THREADED OR THREADED
TO 3" MIN. EACH END

3/4" x 4" SQUARE POLYSTYRENE


(DRILLED AND CUT TO FIT
ANCHOR HEAD)

1" DIAM. POLYETHYLENE


OR PVC PIPE
1 5/8" INSTALLATION WIDTH FOR
2 1/2" COMPRESSION SEAL SIZE

3/4" DIAM. ANCHOR ROD

TOP OF SLAB OR
FACE OF CURB
WRAP BLOCK 2 TIMES
WITH DUCT TAPE

FULLY COMPRESSED SEAL HEIGHT, SEAL


HEIGHT VARIES WITH MANUFACTURER,
VERIFY PRIOR TO SLAB CONSTRUCTION

3/4" x 2 1/2" SQUARE PLATE WITH DRILLED


13/16" DIAM. HOLE IN CENTER

COMPRESSION SEAL TABLE


D.S.BROWN
CV-25021

2 1/2

WATSON BOWMAN
ACME
WA-250

1" x 4" SQUARE POLYSTYRENE


(DRILLED AND CUT TO FIT
ANCHOR HEAD)

STANDARD PLAN A-40.50-01


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

2 1/2

.....

TESTING SHALL BE PER AASHTO M-220 PRIOR TO USE

COMPRESSION SEAL DETAIL

BRIDGE APPROACH SLAB

ANCHOR HEAD DETAIL

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

BEAM GUARDRAIL TYPE 31


TRANSITION SECTION TYPE 21
- SEE STANDARD PLAN C-25.20

EDGE OF SHOULDER
{CURB LINE)

9'- 0"

23'- 0" TAPER

BRIDGE TRAFFIC BARRIER

TAPERED BARRIER TOE

3'- 0"

PLAN

....1
....1

BACK OF

c
c

::::i

BEAM GUARDRAIL TYPE 1

a::

BEAM GUARDRAIL TRANSITION TYPE 1


-SEE STANDARD PLAN C-3

PAVE~~~+ (

EDGE OF SHOULDER
{CURB LINE)
TAPERED BARRIER TOE

LL

BRIDGE TRAFFIC BARRIER

25' - 0" TAPER

3'- 0"

PLAN

VARIES - SEE CONTRACT

3'- 0"

BRIDGE TRAFFIC BARRIER

APPROACH SLAB
{WHEN SHOWN IN CONTRACT)
SEE CONTRACT

ELEVATION
EMBANKMENT

TYPE 21 TRANSITION SHOWN


BRIDGE TRAFFIC BARRIER

EMBANKMENT WIDENING
AT BRIDGE END
WITH WING WALL
STANDARD PLAN A-50.10-00
SHEET 1 OF 2 SHEETS

WING WALL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

ISOMETRIC VIEW

BEAM GUARDRAIL CONNECTION TO BRIDGE TRAFFIC BARRIER

fll

STATE DESIGN ENGINEER

11-17-08
DATE

Washington State Department of Transportation

WIRE ROPE LOOPS


- SEE STANDARD PLAN C-8 \
EDGE OF SHOULDER \
I

(CURB LINE)

BACK OF PAVEMENT
SEAT
SEE NOTE OMIT TAPERED

BARRIER TOE

BRIDGE F-SHAPE TRAFFIC BARRIER

1
lr---.-~---------------------------r----------~------------~,~~~~,r-------~.-----~1111--------------~--------~------~IIII--~L
0

'fl'

ctl

11

, -

11

aF---~b---------------~----------------~~1

"'"
EDGE OF PAVED
EMBANKMENT WIDENING
...J
...J

PRECAST CONCRETE BARRIER


TYPE 2 (UNRESTRAINED)

L.U

Cl
Cl

CONCRETE BARRIER TRANSITION TYPE 2


TO BRIDGE F-SHAPE - SEE STD. PLAN C-8f

VARIES - SEE CONTRACT

:J

c:::

PLAN

L.U
LL.

WITH TYPE 2 UNRESTRAINED BARRIER

WIRE ROPE LOOPS

BACK OF PAVEMENT

-SEE STANDARD PLAN C-8 \


TYPE 3 BARRIER ANCHORS
-SEE STANDARD PLAN C-8e

PRECAST CONCRETE BARRIER


TYPE 2 (ANCHORED)

SEAT

EDGE OF SHOULDER
(CURB LINE) \

SEE NOTE
/
/

OMIT TAPERED
BARRIERTOE

BRIDGE F-SHAIPE TRAFFIC BARRIER

NOTE:

VARIES - SEE CONTRACT

CONCRETE BARRIER TRANSITION TYPE 2


TO BRIDGE F-SHAPE - SEE STD. PLAN C-8f

OMIT BEVELED ENDS ON TOP OF BRIDGE TRAFFIC BARRIER


WHEN CONNECTING TO CONCRETE BARRIERS.

PLAN
WITH ANCHORED BARRIER

1 1/4" PVC CONDUIT


SLEEVE

SEE NOTE

EDGE OF SHOULDER

-------(C~~-~LINE:_\ ___________ --

I
I

THREE #9 (EPOXY COATED) BARS


- SEE STD. PLAN C-14a

I /

\
If Ji'
"'-~ -~b

s.

BACK OF PAVEMENT
SEAT

~~1~'R"~~~D
ml

SINGLE SLOPE CONCRETE BARRIER


(DUAL FACE)

BRIDGE

TRAFFI~ BARRIER
ml

L,

F----dlllllll______________--'~----------------'l'"===lll==l"l

"'"
EDGE OF EMBANKMENT
WIDENING

EMBANKMENT WIDENING
FOR BRIDGE END
WITH WING WALL
STANDARD PLAN A-50.10-00

VARIES- SEE CONTRACT

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

PLAN
WITH SINGLE SLOPE BARRIER

CONCRETE BARRIER CONNECTION TO BRIDGE TRAFFIC BARRIER

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

11-17-08
DATE

Washington State Department of Transportation

BACK OF PAVEMENT
SEAT

BRIDGE DECK

BRIDGE APPROACH SLAB

BEAM GUARDRAIL TYPE 31


TRANSITION SECTION TYPE 21
-SEE STANDARD PLAN C-25.20

EXPANSION JOINT

EDGE OF SHOULDER
(CURB LINE)

BRIDGE TRAFFIC BARRIER

TAPERED BARRIER TOE

....1
....1

c
c

::::i

0::

LL.

3' - 0"

9'- 0"

23' - 0" TAPER

CURTAIN WALL

PLAN

BACK OF PAVEMENT

SEAT~

BRIDGE TRAFFIC BARRIER

3'- 0"

BRIDGE APPROACH SLAB


(WHEN SHOWN IN CONTRACT)

PRECAST GIRDER

CURTAIN WALL
EMBANKMENT

ELEVATION

END PIER

EMBANKMENT WIDENING
AT BRIDGE END
WITH CURTAIN WALL
STANDARD PLAN A-50.20-01

CURTAIN WALL

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ISOMETRIC VIEW

Pasco Bakotich Ill

.....
fll

-----,s=rA=TE=-:D=E=SIG""N'""EN:-:-:Gc:ciN=EE"'"R___

BEAM GUARDRAIL CONNECTION TO BRIDGE TRAFFIC BARRIER

09-22-09
DATE

Washington State Department of Transportation

BRIDGE APPROACH SLAB ~


EDGE OF SHOULDER
(CURB LINE) \
I
:

'-,.

==

1
1=!:

-I

SEAT~

WIRE ROPE LOOPS


SEE STANDARD PLAN C-8

_s-

ll~

Cl
Cl

I
r------------- - b,

BRIDGE TRAFFIC BARRIER

Ill

i' ----------,

Il

0::

LL.

PRECAST CONCRETE BARRIER


TYPE 2 (UNRESTRAINED)

CURTAIN WALL

3'- 0"
EDGE OF PAVED
EMBANKMENT WIDENING

10'- 0"

CONCRETE BARRIER TRANSITION TYPE 2


TO BRIDGE F-SHAPE - SEE STD. PLAN C-8F

PLAN
WITH UNRESTRAINED BARRIER

BRIDGE APPROACH SLAB

TYPE 3 BARRIER ANCHORS (TYP.)


-SEE STANDARD PLAN C-8e ~

vr

EDGE OF SHOULDER
(CURB LINE) \

BRIDGE DECK

EXPANSION JOINT

OMIT TAPERED
BARRIER TOE

__.
__.
w

:J

BACK OF PAVEMENT

BACK OF PAVEMENT
SEAT

BRIDGE DECK

..!_

'J
WIRE ROPE LOOPS
SEE STANDARD PLAN C-8

1--.s-

~ OMIT TAPERED
BARRIER TOE

EXPANSION JOINT

BRIDGE TRAFFIC BARRIER

Ill

CURTAIN WALL

3'- 0"

PRECAST CONCRETE BARRIER


TYPE 2 (ANCHORED)

CONCRETE BARRIER TRANSITION TYPE 2


TO BRIDGE F-SHAPE - SEE STD. PLAN C-8F

PLAN

WITH ANCHORED BARRIER


BACK OF PAVEMENT

SEAT~

BRIDGE APPROACH SLAB ~

EDGE OF SHOULDER
(CURB LINE)\ 11/4" PVC CONDUIT SLEEVE_\

,
C::

I ~~------------~----------~~,,~------~--~

THREE #9 (EP:XY COATED)


- SEE STD. PLAN C-14a

l~RS

_s-

/OMIT TAPERED
BARRIER TOE

EXPANSION JOINT

00

~=---- ~:! ~ = ,

I~

'-'"

Ill

r------------- --

:~~;~;~:~~::;~:::~::;:~:;;:~::.~;:::
3'- 0"

EDGE OF EMBANKMENT
WIDENING

10'- 0"

SINGLE SLOPE CONCRETE BARRIER


(DUAL FACE)

?-

BRIDGE TRAFFICSIARRIER

l~====~==~====~==~====nr=~~==========~~~~~-.--2-----~--~

BRIDGE DECK

!_..

~ ~=-=--=-=--=-=-=--r======'IJ"===II===~
I
Ct>

CURTAIN WALL

EMBANKMENT WIDENING
AT BRIDGE END
WITH CURTAIN WALL
STANDARD PLAN A-50.20-01
SHEET 2 OF 2 SHEETS

PLAN

APPROVED FOR PUBLICATION

WITH ANCHORED BARRIER

09-22-09
Pasco Bakotich Ill
-----------------------STATE DESIGN ENGINEER
DATE

CONCRETE BARRIER CONNECTION TO BRIDGE TRAFFIC BARRIER

.....
VI

Washington State Department of Transportation

EXPANSION JOINT
PIER WALL
BEAM GUARDRAIL TYPE 31
TRANSITION SECTION TYPE 21
- SEE STANDARD PLAN C-25.20

BRIDGE DECK

----r-----T.o------_j \r------f----+-

EDGE OF SHOULDER
(CURB LINE)

TAPERED BARRIER
TOE

RETAINING WALL OR CURTAIN WALL


(OR ACCORDING TO PLANS)

...J
...J

9'- 0"

23' - 0" TAPER

c
c

::::i

PLAN

EXPANSION JOINT

PIER WALL

LL.

BEAM GUARDRAIL TYPE 1

BEAM GUARDRAIL TRANSITION TYPE 1


-SEE STANDARD PLAN C-3

3'- 0"

BRIDGE DECK

----r----T..,----------_j \ r - - - - - - f - - - - + -

EDGE OF SHOULDER
(CURB LINE)

OMIT TAPERED
BARRIER TOE
BRIDGE TRAFFIC BARRIER

-~~~4b==~F=======~

9'- 0"

23' - 0" TAPER

RETAINING WALL OR CURTAIN WALL


(OR ACCORDING TO PLANS)

3'- 0"

PLAN
BEAM GUARDRAIL TRANSITION TYPE 1
- SEE STANDARD PLAN C-3

BRIDGE TRAFFIC BARRIER

PRECAST GIRDER

.
~

3' - 0" (MIN.) OR


SEE CONTRACT PLANS

~'"

EMBANKMENT
------ BRIDGE TRAFFIC BARRIER

END WALL

RETAINING WALL OR CURTAIN WALL


(OR ACCORDING TO PLANS)

ELEVATION

EMBANKMENT WIDENING
AT BRIDGE END WITH
L SHAPED ABUTMENT
STANDARD PLAN A-50.30-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


11-17-08
-----------------------STATE DESIGN ENGINEER
DATE

.....

ISOMETRIC VIEW

BEAM GUARDRAIL CONNECTION TO BRIDGE TRAFFIC BARRIER

fll

Washington State Department of Transportation

EXPANSION JOINT ~

-r

~ BRIDGE DECK

~~------------~

c_

PIER WALL

EDGE OF SHOULDER.~
(CURB LINE)

1 1/4 " PVC CONDUIT \


SLEEVE

\'Jr-----~-f----f-

THREE #9 (EPOXY COATED) BARS


SEE STD. PLAN C-14a
OMIT TAPERED
BARRIER TOE

BRIDGE SINGLE SLOPE TRAFFIC BARRIER

~~-~~~~~~~~~~~~~~~\~~~~~~~~~
/

~;.-_.r-,._

....1
....1

Cl
Cl

::::i

~=~,

111

b~~~~"'i~"""'"'~"""""'9

fi~%t;M~~i~?itfiiff~J~fg~:if~~~:1:J.2__~:======;=\=='
EDGE OF EMBANKMENT

WIDENING

0::

RETAINING WALL OR CURTAIN WALL


(OR ACCORDING TO PLANS)

LL.

SINGLE SLOPE CONCRETE BARRIER

(DUAL FACE)

3'- 0"

PLAN

EXPANSION JOINT ~

Cl

~~----~-------'~\~------~~~--+-

c_

PIER WALL

'J

WIRE ROPE LOOPS - SEE DETAIL ~


STANDARD PLAN C-8

EDGE OF SHOULDER \
(CURB LINE)

""'

CONCRETE BARRIER TYPE 2

BRIDGE DECK

CONCRETE BARRIER TRANSITION TYPE 2

OMIT TAPERED
BARRIER TOE

Ir

BRIDGE F-SHAPE TRAFFIC BARRIER

3' - 0"

-SEE STANDARD PLAN C-Sf

PLAN
CONCRETE BARRIER TYPE 2

WIRE ROPE LOOPS OR EPOXY


COATED BARS (TYP.)

END WALL

BRIDGE TRAFFIC BARRIER

'
''=------''

RETAINING WALL OR CURTAIN WALL


(OR ACCORDING TO PLANS)

EMBANKMENT WIDENING
AT BRIDGE END WITH
L SHAPED ABUTMENT
STANDARD PLAN A-50.30-00
SHEET 2 OF 2 SHEETS

ELEVATION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

CONCRETE BARRIER CONNECTION TO BRIDGE TRAFFIC BARRIER

fll

STATE DESIGN ENGINEER

11-17-08
DATE

Washington State Department of Transportation

CEMENT CONCRETE CURB AND GUTTER \

APPROACH SLAB

CEMENT CONCRETE SIDEWALK \

BACK OF PAVEMENT SEAT

~------- BRIDGE DECK

w~.--;....

~ ,..--

EXPANSION JOINT (TYP.}

BRIDGE SIDEWALK

""7"

'
BEAM GUARDRAI ~ TYPE 31 \

{:~; ~:!~~~~~~~%~~iig~ij~~~&I::!~:,~~~~t~~id;~~--~--'---

....1
....1

c
c

::::i

!!!!

\ _ BRIDGE PEDESTRIAN BARRIER

0::

WIDENING

LL.

23' - 0" TAPER

VARIES -AS SHOWN IN PLANS

9'- 0"

PLAN
CEMENT CONCRETE CURB AND GUTTER \

CEMENT CONCRETE SIDEWALK \


WITH RAISED EDGE - SHOWN
\

=
co . - - -

APPROACH SLAB

WITH GUARDRAIL

BACK OF PAVEMENT SEAT

~ ,..--

BRIDGE DECK

~ ,..--

BRIDGE SIDEWALK

'

;....

\
EXPANSION JOINT (TYP.}

~
""7"

'

11

Co-t---r.:~:7:7~/.~'/:::-::;:7.~7:7~N7;K'/~M:-;:;;::~;~7;;77;;:7;;:'/::;::::-:;::-::;::7:;~_7;:;~7</:;::::::;~7.iV7;:.-7::::7:;:/_,::"/:::;~~i:;:.7~:~7;;~7:;:/::;;::-::~;;:::~~7~;;7:~~7;~7;~::-::;~~:::~:~~:;:7~;~7::;:7;;:/~:~::-:::~;:::~~7:~:7:;~;7;~fb= =========91p=====\_==B=RI=D=G=E~P~=E=D=ES=T==9RIAN
WIDENING

BARRIER

3' - 0"
20' - 0" TAPER

VARIES -AS SHOWN IN PLANS

PLAN
WITH PEDESTRIAN RAILING

3'- 0"

PEDESTRIAN RAILING
(WHEN SHOWN IN THE CONTRACT}

~~~~nn~~~~~~~nn~nm~~~~~nn~~~~~~~nn~ll

VARIES -AS SHOWN IN PLANS

BRIDGE PEDESTRIAN RAILING

I I I I I I I I I I I I I I I I I I I I I

BRIDGE PEDESTRIAN BARRIER

I I I I 11/11 I I I I I

I I

j
EMBANKMENT WIDENING
AT BRIDGE END WITH
SIDEWALK
STANDARD PLAN A-50.40-00
SHEET 1 OF 1 SHEET

1:-.....---'h-- SEE CONTRACT

Pasco Bakotich Ill

ELEVATION

-,
'

SIDEWALK CONNECTION TO BRIDGE PEDESTRIAN TRAFFIC BARRIER

APPROVED FOR PUBLICATION

.....

fll

STATE DESIGN ENGINEER

11-17-08
DATE

Washington State Department of Transportation

....1
....1

0
0

::::i

z
a::
w

LL.

1-

w
:::!:

~
w
w

1-

a::
z

(.)

(.)

1-

w
:!:
w
(.)

- - . .. .. .. .
...
. . . . . . . .
. . . ......
.
. ."'" ... . . .. -. . .....
~~~~~~~~~~~~~~---~~~-~--~-~-----~
..~.~-~-~-~.~.-.+.~.~~~-.-.-.~.~-~-~-~~~~~~~~~~~-.-.-.~.~.7.~.~.-.~.~~~~~~~~~~~~~~~~~~~~~-~~~-.-.~-~-~-~~~~~-~-~~~~~~~~~~~~~~-~~~~~~:~~~~~~~~~~~:
..... .. .
. ......... .. . .
.... ... ...
. .
....
:: ::: . . . . . .
. . . . . . . . . . . . . . . . . .... . . . . . . .
. . . :::: ...".
. ... .
. .....

... ...

....

~-:.:..:..:._ ..:. . .:. . -~--~: .:..:_:2.~-:~.:..._:_ ....;....:_,..:_:_

.. ..

....:.....:.

___;,,

. .....
. . . .
..
. . . . . . . . . . . . . ::: .... .... :: .. .
.
. ... .. .
. . . . . . . . . . . .. .. .
. .
. . . . . .. . . ... .
...
... . .
. . . .
...
. .
. ..:......;....
...
.
...:.....:.... . .:~ -.:. :. :. :.: .:..:...:.. .:..:....... ~ .:....:...: .:....:...: -~ ...;....;... .. .:. . :. . ....:.....:..,. ~: ....:....:: -..:..:...:: ~..:..:..:... ...:....:... ..:. . .:. ,. ....:....:.. ....:....:.\...:....:.: .:..:....... ,_,__. .:....:...: -~ -~ .. .:. . :. . ....:....:.... ~ :. . :. :. : :..:..:..:..:NOTE:S ...:....:... ...:........ ....:....:. ....:....:.. -...:..:..:.: ..:..:..:._: ;_;_..:....:....: .. .

........:....

SEE STD. PLAN A-40.10


FORTRANSVERSE ~~--------
JOINT DETAILS

PLAN VIEW

\_

EXISTING EDGE
OF SHOULDER {TYP.)

PANEL REPLACEMENT
NEW TIE BARS
3' MAX. ON CENTER

EXISTING TRANSVERSE JOINT


. . . . .
.

EXISTING
LONGITUDINAL
JOINT

. :~~~z~::::: : -: : .

. . . . .
. . . . .

::::::EXISTING CEMENT CONCRETE

. CONCRETE: : : t : : : : : : . . .......
PAVEMENT .... I.. .L. . . .. .. I.
. I ..... "I ... . .
-------'---1 ... 1 ..

. I :

I.
I

. . .I. .
.I.

P~VEMENT::.:.:.:.::: l::: .:: ~~~Z~.

: . : : : : : : : : . ~- ...... =
"l" . . . ~.

< >. :.< .< .< . : :1 :

... .JI

I
I

. 0

. : ::: : : CONCRETE ...


1 PAVEMENT ..

...r

.,.... .. J .

. I

..
1 .... . .

.1.
I

I
I

::: ..

1/2 CONCRETE
PAVEMENT DEPTH

: CONCRETE .
.. : PAVEMENT:

.---

~~
oz
00
3:N
w..-

Place new dowel bars between existing dowel bars.


Don't place any dowel bars closer than 1' - 0"
from edge of concrete panel.

9"

SAWED GROOVE SEE STD. PLAN A-40.10

r.-~~~~-~.-.-.~_--+-~--~~~t~----------------------

en

a:: a::

!Ilf...JZ

3.

NEW CEMENT CONCRETE PAVEMENT

EXISTING CONCRETE PAVEMENT

NEW CEMENT
CONCRETE PAVEMENT

Place polyethylene film (per AASHTO M171) or building


paper along the longitudinal joint between partial panel
replacement and existing panel.

SAWED GROOVE {TYP.)

. . EXISTING..-~
. CEMENT..

2.

----------:-~'"=.

1 - ---

<Cw

1. Install tie bars along longitudinal joints between full panel


replacement and existing cement concrete pavement.
Tie bars are not installed between cement concrete
pavement and hot mix asphalt shoulders.

--- -.-

EXISTING ..

--- .: : CEMENT .
: : : CONCRETE.
..:..: . PAVEMENT

......l

. . . . . .
. ...
:- :: : : :- : .. : :: : :~:~ --
................. .--...:

--

-0

DRILL 1 3/4" MIN. TO 2" MAX. DIAM. x 9" LONG


HOLE IN EXISTING CEMENT CONCRETE
FOR NEW DOWEL BAR {TYP.)

SECTION

.....

-:... .:..._....:. ____

---'--~~~~~~~~~~~~~~~~~~--.~~~....1----

CEMENT CONCRETE
PAVEMENT REPAIR

NEW DOWEL BAR 1 1/2" DIAM. X 18"

STANDARD PLAN A-60.10-01


SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

- - - - - - - -

Pasco Bakotich Ill

PLAN VIEW

COMPLETE PANEL REPLACEMENT DETAIL

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

EXISTING TRANSVERSE JOINT

NEW CEMENT CONCRETE


PAVEMENT- COMPLETE PANEL
(DOWEL BARS NOT SHOWN)

1'- 6"

NEW TIE BARS


3' MAX. ON CENTER

3' MIN.

3' MIN.

EXISTING TRANSVERSE JOINT

.. .I
EXISTING
LONGITUDINAL
JOINT

SEE STD. PLAN A-40.10


FOR LONGITUDINAL I
JOINT DETAILS

.. EXISTING : : : 1
:- : -: . CEMENT -: : -::
: : .CONCRETE . : : .1

...

. . . PAVEMENT. .I
..

. EXISTING
. . : . : . CEMENT ...
. CONCRETE.

. . . .

. ..

1 - --- ~'"." ...

:<: :- .. . .- ---- <)


.

~ :~:

. . . ~--

. . . .
..........

DOWEL BAR (TYP.)

.w/

a:: a::

CEMENT
CONCRETE

CONCRETE
PAVEMENT . ...,..: --

. . .

-":"

--

l.. --
.

. . . .
. . . . . .,.._
..
.
. ..

- - - - - --

PAVEMENT

. I. .
. I. . .

~ ~

...J

. . . . .

-- :-.:..: : : EXISTING :

LU LU

:s:u

oz

00
:5:
~
LU .,....
z

. . . . . I ..
. . . . . I .
. . . . . I .

--- -~-=-: ....

CEMENT. . .
CONCRETE:

..

. CONCRETE ..

. . .

. . . ... ..

(/)

a:: a::

. . . . .

. :::: . : EXISTING.::::.

. l . .
. .
. 1 ..PAVEMENT . .
. .1'.
. I
. I . .

~~

. EXISTING . . -...:~ --
:CEMENT ..... ..

NEW

. CONCRETE ..

PCCP

...JZ

: PAVEMENT.::~~.:. --

~
A

:. :. :::.:.:

--- -.-.

. . . . . . l. --- --

-:. :-:.:-:. :-:: ....


..........

...

. . .

~- ~ ~~L:...,..-----------,-----l~ ~ ~-~ ~ .:..::.._~- ~:~ ~ ~..:. -~ J_:_- ~:~ :~ ~ ~:..:. ~ ~-~.

. . .
. . .

. .

. EXISTING .

:s:u
--- .--
..
oz
. : : : CONCRETE .
CEMENT...

00
--- _.:.,. . PAVEMENT .
:5:~
LU.,....

. . . . ...r...

--- --~

LULU

.... '1 ....

....

PAVEMENT.

.,....

: : : : : CEMENT .
. I .... CONCRETE:

:PAVEMENT

. .CEMENT ...

SAWED
GROOVE
(TYP.)

. . . .

.......... r ...

(/)

NEW

. . ..

-:_.II:_-:. .. .. .... ........ .

.:::::_::::::::::-::::::

EPOXY COATED

. EXISTING ... -.-- --


CEMENT ..... .

. .

. . . . .
I
. . . . . . . 'L

. ~-:-:-:.....:.. ...:....:-~:~,...,.,...

..........
. . .

.
. . EXISTING
.
.
. . . . . .

.
..

. . . ...I. .b

. -: EXISTING. . .
. 1.
.
. . 1
. .CEMENT....
.(
..... CONCRETE : . : : : .... : ::
-:.: PAVEMENT

---~~~""':....:.:_...:.._;1

........ .

EXISTING
LONGITUDINAL
JOINT

--- .....

~;

...
. . ..... . .

~
A

--- --

:.... . : . . . . _ - - ..... ....&. ....: - - :__.:....:.....:.

L...---------r-----l.:.....:....:.....: _._ ._ .:......:..._-- ""'-....:.

I.

SAWED GROOVE
(TYP.)

6' MIN.

.I

PLAN VIEW

PLAN VIEW

PARTIAL PANEL REPLACEMENT

PARTIAL PANEL REPLACEMENT

WITH TIE BARS

WITHOUT TIE BARS

NEW CEMENT CONCRETE PAVEMENT

EXISTING CEMENT CONCRETE PAVEMENT


15"

1/2 CONCRETE

SAWED GROOVE SEE STD. PLAN A-40.1 0

PAVEMENT DEPTH

r - - - - - - - - - - - - - - - - - - - t r - - -.-.-- -.- .-:--:--:-.-.-:-.

7'....,

.-.-

~--- : - - - : - : - .

CEMENT CONCRETE
PAVEMENT REPAIR

- ----------~----:---~:~:---:-.-::-:::-:T:::

STANDARD PLAN A-60.10-01


DRILL 7/8" MIN. TO 1 1/8" MAX. DIAM. x 15" LONG
HOLE IN EXISTING CEMENT CONCRETE
FOR NEW TIE BAR

NEW TIE BAR - #5 x 30" EPOXY


COATED REINFORCING BAR

SECTION

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

- - - - ------ROADWAY

....1
....1

______ s?

It-----------

Cl
Cl

MEDIAN

::::i

DOWEL BAR (TYP.) - SEE


PLACEMENT DETAIL, SHEET 2

I
I

0::

w
LL.

Cl

:5

OR

:5

P"

:5

1i)
~

w
DOWEL BAR (TYP.) - SEE

:5

PLACEMENT DETAIL, SHEET 2

Cl

P"

EXISTING
CEMENT
CONCRETE ~
PAVEMENT

DOWEL BAR (TYP.)- SEE

EXISTING
CEMENT
CONCRETE
PAVEMENT

PLACEMENT DETAIL, SHEET 2

EXISTING Z
CEMENT
CONCRETE ~
PAVEMENT 00

:5

1:::J

SKEWED TRANSVERSE
CONTRACTION JOINT
SEE STD. PLAN A-40.10

PLAN VIEW

SKEWED JOINT DETAIL

LANE

L
PLAN VIEW

PLAN VIEW

DOWEL BAR RETROFIT

DOWEL BAR RETROFIT FOR ONE LANE

FOR TWO LANE DIVIDED HIGHWAY (ONE WAY TRAFFIC)


FOR EACH LANE IN UNDIVIDED HIGHWAY (TWO WAY TRAFFIC)

DIVIDED HIGHWAY (ONE WAY TRAFFIC)

SECTION
INSIDE LANE

1V ~

1'- 6"

\7 '

I
17

OUTSIDE LANE

1'- 6"

'7 . ~
. I>

I>

~ '

I>

I>

I>

SECTION

17

LANE

LANE

I> I
P'

V' . ~

. I .

DOWEL BAR RETROFIT


FOR CEMENT
CONCRETE PAVEMENT
STANDARD PLAN A-60.20-02
.

I>

SHEET 1 OF 2 SHEETS

17 .

I>

APPROVED FOR PUBLICATION

SECTION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

,,____.....c- TRANSVERSE CONTRACTION JOINT

....1
....1

::::i

1 1/2"
{TYP.)

0::

'
'

3/8" FOAM CORE BOARD FILLER


MATERIAL TO- MAINTAIN JOINT

Cl
Cl

LL.

.. ..:. J_.lLJ' ... . .

9"

:-:.:>:. .. . ....

.. . . . . . .

'

::.::::
. . ~
. . . .

DOWEL BAR

Cl

1/4" {TYP.)

. . . .

EXPANSI~N j

EXISTING CEMENT CONCRETE PAVEMENT

... ...

. ..
. _-

: \oN:CRETEPATCH .:.:: . ::.:...:::.....:


... : MATERIAL.

~~

:. . .. . .. .:
. ............. .':.:: .. ..

. . . . . . .... ..
....

... .: .

:-:-:-:-r lT l:->. . . : .. . .

\ _ CHAIR {TYP.)
- PREFABRICATED

DOWEL BAR
CAP- BOTH ENDS

LENGTH NEEDED FOR DOWEL BAR PLACEMENT

PLAN VIEW
TOP OF PAVEMENT AFTER GRINDING
{NOT INCLUDED IN BID ITEM)
TOP OF EXISTING CEMENT
CONCRETE PAVEMENT

... . .

[>

CENTER OF
SAW

3/8" FOAM CORE BOARD DRILL 1 1/2" DIAM. HOLE - - FOR DOWEL BAR

. . . .. . .. .
'

::-::.-~oiu.s vA~IEs

..

... DEPENDING ON .
. . SAW BLADE DIAM.
'V.,.

P'

.. .

..

[>

"

.: ...

'V . :

DOWEL BAR

[>

17'

[>

[>
[>

'

.. .

[>

. t>

[>

17

~
.. t>.

'Q',

P'

'. 17 .
[>

17.:

'

'V .

P'

'

11

t>

DOWEL BAR EXPANSION CAP , . '


'
17 . :
. ' .
{TYP .) t>. . :
t>
'V :
'
' i
.
l'">

"'.

'

'V . :

. ' '. .'.':.::>. ........ .

17.
..

..

17 .

[>

[>

[>

'V . :

[>

'

I>

~ . '
CHAIR

'

'V.:

[>

.
CAULKING FILLER

17.

. "

[>

17 . :

[>

6" MIN.

'

[>

t>

17 .

[>
..

[>

'V.:

II'

yo,..

II'

'

'V.

[>

.
[>

17

17.'
.

t>

17.:
[>

[> ' '

TRANSVERSE CONTRACTION JOINT

[>

EXISTING CONCRETE PAVEMENT

'V . :

'

17 :

17 . :

[>

P'

[>

17.

'

[>

'

[>
[>

[>

t>

[>

SECTION

TOP OF EXISTING CEMENT


CONCRETE PAVEMENT

17 .
- [>

17.'

..

. ..... '

'

BOTTOM OF SLOT
IS PARALLEL TO
PAVEMENT SURFACE

DOWEL BAR PLACEMENT DETAIL

TOP OF PAVEMENT AFTER GRINDING


{NOT INCLUDED IN BID ITEM)
::.;.~.---;~-~-~-~-.;...

..... , w

i:--~~--

I- I- .

17W ll..

[>

17 . '
(f)

0::

." t>

~0

.. . . ' u.

~ ~

'N

w z

_.

ClQ
t-U

[>

z w
w w

17

!z ' .
::::2: .. t>

,17

t>
'V

:;c

17

t>
'

[>

DOWEL BAR RETROFIT


FOR CEMENT
CONCRETE PAVEMENT
STANDARD PLAN A-60.20-02

'

;:: c...'

tcHAIR

'.

'.Q w .'

DOWEL BAR

ll. 1-

CONCRETE .
~
.' PATCH t> . ~
. MATERIAL.
u w .

17 .

'
[>

17 .

::!:(f)

:;c

[>

'

17 .

t>

ll.
..

[>

17

..

SHEET 2 OF 2 SHEETS

"' :

'. ~ EXISTING CEMENT t> ,


. ' CONCRETE PAVEMENT .

. t>

'V . :

SECTION

....

P'

'1;1

17

CHAIR DETAIL

[>

CHAIR TO REST
PARALLEL TO
SURFACE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

NOTES
1. A typical bridge overlay will remove 0.07 feet of Asphaltic Concrete Pavement (ACP)
and place 0.15 feet of new Hot Mixed Asphalt (HMA). Depth of removal and placement will vary for each bridge. Total depth of HMA on the bridge shall not exceed
0.25 feet, unless shown otherwise in the plans.
BRIDGE DECK

0.2% MAX. FINAL GRADE TRANSITION

2. If the existing depth of asphalt on the bridge deck is 0.25 feet, then the overlay will
remove 0.15 feet of ACP and place 0.15 feet of new HMA. The existing bridge grade
will remain unchanged.

SEE NOTE 3
BACK OF PAVEMENT SEAT
0.25' HMA - MAX DEPTH

lf
LJl

EXISTING 0.15' HMA W/ MEMBRANE


EXISTING BRIDGE GRADE

SEE BRIDGE PLANS FOR JOINT DETAILS,


OR STD. PLAN A-40.20, JOINT DETAIL 8.

EXISTING ROADWAY GRADE

[::>

[>

. "

""

3. FINAL GRADE TRANSITION: The maximum longitudinal taper slope to transition an


increase in roadway grade to the new or existing bridge grade will be at most 1 inch
rise to 40 feet run (1V:480H or flatter) (0.2% maximum). If several overlays are
present, extended taper lengths shall be required to maintain the transition slope
(1V:480H or flatter) (0.2% maximum).

0.2% MAX. -

11

' . ".
4

FINAL ROADWAY GRADE

~-~-=.:~.=-~:.=::.:::-.=::::::-.:::::.::.:::::::::.::.:::::::::-:.::::::;-:::;-:-;.;:.-:;.-=nn--,...

4. If the ACP and membrane is to be removed from the bridge deck, see GSP 023106
for deck preparation before placing new membrane.

... - - -

b
~

..

I>

""

I>

..

""

5. In accordance with Standard Specification 5-05.3(12), when pavement abuts bridges,


the finished pavement parallel to centerline shall be uniform to a degree that no variations greater than 1/8-inch are present when tested with a 10-foot straightedge.

HMA PAVEMENT

[>

PLANED DEPTH

I' " .
1" MIN. EXISTING ACP

7' . " .

ELEVATION VIEW

HMA OVERLAY WITHOUT BRIDGE APPROACH SLAB

BRIDGE DECK

BRIDGE APPROACH SLAB

0.2% MAX. FINAL GRADE TRANSITION


SEE NOTE 3

BACK OF PAVEMENT SEAT


0.25' HMA - MAX DEPTH
FOR HMA PAVEMENT, SEE STD.
PLAN A-40.20, JOINT DETAIL 1.

FINAL ROADWAY GRADE


EXISTING ROADWAY GRADE

EXISTING 0.15' HMA W/ MEMBRANE


EXISTING BRIDGE GRADE
0.2%MAX. _

4. '" . "
[7

..

"

I>

..

""

""

I>

PLANED DEPTH

I " .
v

..

1" MIN. EXISTING ACP

7' ' " .

..

t>

~
[>

"

"

"
"

"

"

"
"

"

"

"
b

"
"

"

"
0

HMA PAVEMENT

BRIDGE DECK TRANSITION


FOR HMA OVERLAY

:"

STANDARD PLAN A-60.30-00


ELEVATION VIEW

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

HMA OVERLAY WITH BRIDGE APPROACH SLAB

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

11-8-07
DATE

State Department of Transportation

....1
....1

c
c

::::i

2" MIN.
(TYP.)

0:::

--I-

LL

TRANSVERSE REBAR (TYP.)

EXISTING DELAMINATION

EXISTING DELAMINATION

1/2" DEEP SAWCUT (TYP.)

NOTES

TOP OF EXISTING BRIDGE DECK

1. If a zone has rebar section loss or full depth repairs,


then the concrete deck repair in each zone shall achieve
3,000 PSI before progressing to the adjacent zone.

LONGITUDINAL REBAR (TYP.)

-l---

2. Remove all concrete 3/4" minimum clearance around


all exposed reinforcement bars in accordance with
Standard Specification 6-09.3(6).

CONCRETE REMOVAL AREA

DELAMINATION
SECTION

0
1/2" DEEP SAWCUT (TYP.)

EXISTING DELAMINATION

TOP OF EXISTING BRIDGE DECK

4. For typical rebar repairs, when the reinforcement has


greater than 20% section loss (or damage), remove
concrete a minimum of 2' - 6" on each side of section
loss, and replace with new supplemental reinforcement,
same diameter as original, adjacent and parallel to the
deficient bar, extending 2' - 3" beyond each end of
section having 20% section loss.

PLAN VIEW
TOP TRANSVERSE
REINFORCEMENT (TYP.)

FOR DELAMINATION AND


FULL DEPTH REPAIR

3. For tension zones of continuous structures, when a


longitudinal reinforcement bar has greater than 20%
section loss (or damage), remove concrete a minimum
of 3' - 6" on each side of section loss and place 2 supplemental reinforcement bars, adjacent and parallel to
the deficient bar, extending 3' - 0" beyond each side
having 20% section loss. Mechanical splices may be
used to facilitate placement of #4 reinforcement bars.

FULL DEPTH REPAIR


SECTION

DELAMINATION AND FULL DEPTH REPAIR


LEGEND
'

'

-+-----1--SUPPLEMENTAL TOP
TRANSVERSE REBAR

TRANSVERSE REBAR (TYP.)


EXISTING DELAMINATION
EXISTING DELAMINATION
CONCRETE REMOVAL AREA

SUPPLEMENTAL TOP
LONGITUDAL REBAR

DEFICIENT TOP
TRANSVERSE REBAR

7'- 0" MIN.

PLAN VIEW

PLAN VIEW
1/2" DEEP SAWCUT (TYP.)

1/2" DEEP SAWCUT (TYP.)


TOP OF EXISTING BRIDGE DECK

EXISTING DELAMINATION

EXISTING DELAMINATION

TOP OF EXISTING BRIDGE DECK


TOP TRANSVERSE
REINFORCEMENT (TYP.)

HMAOVERLAY
FURTHER DECK
PREPARATION
STANDARD PLAN A-60.40.00

TOP TRANSVERSE
REINFORCEMENT (TYP.)

SECTION

TRANSVERSE REBAR REPAIR

SHEET 1 OF 1 SHEET

SECTION

LONGITUDINAL REBAR REPAIR


(FOR CONTINUOUS STRUCTURES)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

08-31-07
DATE

fJ'I Washington State Department of Transportation

NOTES

PIPE

ALLOWANCES

PIPE MATERIAL

1. As acceptable alternatives to the rebar shown in the PRECAST BASE


SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.

MAXIMUM
INSIDE
DIAMETER

REINFORCED OR
PLAIN CONCRETE

12"

ALL METAL PIPE

15"

CPSSP *
(STD. SPEC. 9-05.20)

12"

2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.

FRAME AND VANED GRATE

SOLID WALL PVC


(STD. SPEC. 9-05.12(1))

3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.

15"

PROFILE WALL PVC


(STD. SPEC. 9-05.12(2))

4. The frame and grate may be installed with the flange down, or integrally
cast into the adjustment section with flange up.

15"

5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.

*CORRUGATED POLYETHYLENE
STORM SEWER PIPE
)

6. The opening shall be measured at the top of the Precast Base Section.

2", 4", 6", 12", OR 24"

7. All pickup holes shall be grouted full after the basin has been placed.

ONE #3 BAR FOR 6" HEIGHT


INCREMENT (SPACED EQUALLY)

RECTANGULAR ADJUSTMENT SECTION

#3 BAR EACH CORNER


18" MIN.

#3 BAR EACH CORNER

CATCH BASIN TYPE 1


#3 BAR HOOP EACH SIDE

#3 BAR HOOP

STANDARD PLAN B-5.20-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
#3 BAR EACH WAY - - -

(SEE NOTE 1)

PRECAST BASE SECTION

ALTERNATIVE PRECAST BASE SECTION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

NOTES
PIPE

ALLOWANCES

PIPE MATERIAL

1. As acceptable alternatives to the rebar shown in the PRECAST BASE


SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot, shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.

MAXIMUM
INSIDE
DIAMETER

REINFORCED OR
PLAIN CONCRETE

18"

ALL METAL PIPE

21"

CPSSP *
(STD. SPEC. 9-05.20)

18"

2. The knockout shall not be greater than 26", in any direction. Knockouts
shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a
1.5" minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.

FRAME AND VANED GRATE

SOLID WALL PVC


(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
(STD. SPEC. 9-05.12(2))

~"
~

3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.

21"

4. The frame and grate may be installed with the flange down or integrally
cast into the adjustment section with flange up.

21"

5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.

*CORRUGATED POLYETHYLENE
STORM SEWER PIPE

4" 6" 12" OR 24"

6. The opening shall be measured at the top of the Precast Base Section.
7. All pickup holes shall be grouted full after the basin has been placed.

ONE #3 BAR FOR EACH 6" HEIGHT


INCREMENT, SPACED EQUALLY

RECTANGULAR ADJUSTMENT SECTION


#3 BAR HOOP

#3 BAR EACH CORNER


18" MIN.

#3 BAR
EACH CORNER

TWO #3 BAR
HOOPS

REDUCING SECTION

CATCH BASIN TYPE 1 L


STANDARD PLAN B-5.40-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
(SEE NOTE 1)

PRECAST BASE SECTION

ALTERNATIVE PRECAST BASE SECTION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

NOTES
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot, shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 18". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.

FRAME AND VANED GRATE

3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate may be installed with the flange down, or integrally
cast into the adjustment section with flange up.

~
~

5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.

2" 4" 6" 12" OR 24"

6. The opening shall be measured at the top of the Precast Base Section.
7. All pickup holes shall be grouted full after the basin has been placed.

ONE #3 BAR FOR EACH 6" HEIGHT


INCREMENT, SPACED EQUALLY

----=~

RECTANGULAR ADJUSTMENT SECTION

#3 BAR EACH CORNER


18" MIN.

#3 BAR EACH CORNER

#3 BAR HOOP

CATCH BASIN TYPE 1 P


(FOR PARKING LOT}
STANDARD PLAN B-5.60-01
SHEET 1 OF 1 SHEET

#3 BAR EACH SIDE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

#3 BAR EACH WAY


(SEE NOTE 1)

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

PRECAST BASE SECTION

ALTERNATIVE PRECAST BASE SECTION

NOTES
1. No steps are required when height is 4' or less.
2. The bottom of the precast catch basin may be sloped to facilitate cleaning.
3. The rectangular frame and grate may be installed with the flange up or down.
The frame may be cast into the adjustment section.

:>-:

4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide
a 1.5" minimum gap between the knockout wall and the outside of the pipe. After
the pipe is installed, fill the gap with joint mortar in accordance with Standard
Specification 9-04.3.

CATCH BASIN FRAME AND VANED GRATE


OR MANHOLE RING AND COVER

CATCH BASIN DIMENSIONS


RECTANGULAR ADJUSTMENT SECTION
OR CIRCULAR ADJUSTMENT SECTION

(.)

~w

1-

0::

!:S

...

C>

MIN.
MIN.
CATCH
WALL
BASE
BASIN
DIAMETER THICKNESS THICKNESS

MAXIMUM
KNOCKOUT
SIZE

MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS

48"

4"

6"

36"

8"

54"

4.5"

8"

42"

8"

60"

5"

8"

48"

8"

72"

6"

8"

60"

12"

84"

8"

12"

72"

12"

96"

8"

12"

84"

12"

120"

10"

12"

96"

12"

144"

12"

12"

108"

12"

..

.. ..
..
..
..
..
...

..

FLAT SLAB TOP

..
:,; .
...
: b'

: . ~t----_ _ _ _ _S_E_E_T_AB_L_E_ _ _ _-----1 ;


'I>. ..

'I> ...

MORTAR {TYP.)

STEPSORc
LADDER

PIPE ALLOWANCES
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
CATCH
SOLID
PROFILE
ALL
CPSSP
CONCRETE
BASIN
METAL
WALL
WALL
DIAMETER
G)
Pvc
Pvc
REINFORCING STEEL {TYP.)

SEPARATE BASE

INTEGRAL BASE

PRECAST

PRECAST WITH RISER


{48"- 72" ONLY)

48"

24"

30"

24"

30"

30"

54"

30"

36"

30"

36"

36"

60"

36"

42"

36"

42"

42"

72"

42"

54"

42"

48"

48"

84"

54"

60"

54"

48"

48"

96"

60"

72"

60"

48"

48"

120"

66"

84"

60"

48"

48"

144"

78"

96"

60"

48"

48"

CATCH BASIN TYPE 2


STANDARD PLAN B-10.20-01
SHEET 1 OF 1 SHEET

G) Corrugated Polyethylene Storm Sewer Pipe (Standard Specification 9-05.20)


(Standard Specification 9-05.12(1))
@ (Standard Specification 9-05.12(2))

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

NOTES

1. The pipe supports and the flow restrictor shall be constructed of the same material and be anchored
at a maximum spacing of 36". Attach the pipe supports to the manhole with 5/8" stainless steel expansion
bolts or embed the supports into the manhole wall 2".
REMOVABLE
WATERTIGHT
COUPLING

2. The vertical riser stem of the flow restrictor shall be the same diameter as the horizontal outlet
pipe with a minimum diameter of 8".

3. The flow restrictor shall be fabricated from one of the following materials:
0.060" Corrugated Aluminum Alloy Drain Pipe
0.064" Corrugated Galvanized Steel Drain Pipe with Treatment 1
0.064" Corrugated Aluminized Steel Drain Pipe
0.060" Aluminum alloy flat sheet, in accordance with ASTM B 209, 5052 H32 or EPS
High Density Polyethylene Storm Sewer Pipe

PLATE WITH
ORIFICE

ELBOW DETAIL

4. The frame and ladder or steps are to be offset so that: the shear gate is visible from the top; the climb-down
space is clear of the riser and gate; the frame is clear of the curb.

5. The multi-orifice elbows may be located as shown, or all placed on one side of the riser to assure ladder
clearance. The size of the elbows and their placement shall be specified in the Contract.
6. Restrictor plate with orifice as specified in the Contract. The opening is to be cut round and smooth.

PLAN VIEW

7. The shear gate shall be made of aluminum alloy in accordance with ASTM B 26 and ASTM B 275,
designation ZG32A; or cast iron in accordance with ASTM A 48, Class 308.
The lift handle shall be made of a similar metal to the gate (to prevent galvanic corrosion}, it may be of solid
rod or hollow tubing, with adjustable hook as required.

ADJUSTABLE LOCK HOOK


WITH LOCK SCREW

MANHOLE RING AND COVER


WITH LOCKING BOLTS,
MARKED "DRAIN"

A neoprene rubber gasket is required between the riser mounting flange and the gate flange.

1" DIAM. ROD OR TUBING

Install the gate so that the level-line mark is level when the gate is closed.
The mating surfaces of the lid and the body shall be machined for proper fit.

HANDHOLD
LIFT HANDLE

ATIACHMENT

STEPS OR LADDER

----~---.,

8. The shear gate maximum opening shall be controlled by limited hinge movement, a stop tab,
or some other device.

9. Alternative shear gate designs are acceptable if material specifications are met and flange bolt pattern matches.

SET OVERFLOW ELEVATION

TO PROVIDE DETENTION AS

All shear gate bolts shall be stainless steel.

_____

SHOWN IN THE CONTRACT


LIFT HANDLE

LIFT HANDLE
PIPE SUPPORT 3" x 0.075" ALUMINUM
OR 3" x 0.079" STEEL
(SEE NOTE 1)

SHEAR GATE
8" MIN. DIAM.

MAXIMUM OPENING

1/2" HOLES ON 10 3/8"


BOLT CIRCLE

MORTAR (TYP.)
FLOW RESTRICTOR
RESTRICTOR PLATE
WITH ORIFICE
(SEE NOTE 6}

---it:----+~

CATCH BASIN TYPE 2


WITH FLOW RESTRICTOR

54" DIAM. MIN.


LEVEL LINE
(SEE NOTE 7)

STANDARD PLAN B-1 0.40-00

CLOSED
FRONT

SHEET 1 OF 1 SHEET
SIDE

VIEW0

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

SHEAR GATE DETAILS

STATE DESIGN ENGINEER

fJ'I Washington

06-01-06
DATE

State Department of Transportation

NOTES

1. See Contract for size and location of all pipes and orifices.

6" MIN.

J:

(.)

(.)

2.

:iii

REMOVABLE, WATERTIGHT COUPLING

ELBOW- SEE DETAIL

<X:

GROUTED

:>-:

3. Precast baffle shall be keyed and grouted in place.

-~-

BAFFLE WALL

Ill

Baffle wall shall have #4 Bar at 12" spacing each way.

4.

Cl

Bottom orifice plate shall be galvanized steel with a minimum thickness of 1/4". Attach orifice with 1/2" stainless
steel bolts.

-0

BAFFLE WALL
PLATE WITH ORIFICE

5. Upper flow orifice plates and elbows shall be aluminum,


aluminized steel or galvanized steel. Galvanized steel
shall have Treatment 1.

ELBOW DETAIL

PLAN

MANHOLE RING - COVER


REMOVED FOR CLARITY

ACCESS - MANHOLE RING, COVER,


AND ADJUSTMENT SECTIONS
REMOVED FOR CLARITY

MANHOLE RING AND COVER WITH


LOCKING BOLTS, MARKED "DRAIN"

TOP OF
BAFFLE WALL

ELBOW- SEE DETAIL


ELBOW- SEE DETAIL

STEPS OR
LADDER

BAFFLE WALL
GROUT
BOTTOM ORIFICE PLATE
UPPER FLOW ORIFICES

CATCH BASIN TYPE 2


WITH BAFFLE TYPE
FLOW RESTRICTOR
STANDARD PLAN B-1 0.60-00

BOTTOM FLOW ORIFICE

SHEET 1 OF 1 SHEET
BOTTOM ORIFICE
PLATE

A
(72" MIN.)

SECTION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

ISOMETRIC CUTAWAY

STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

NOTES
MANHOLE RING AND COVER

1. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum.


2. For pipe allowances, see Standard Plan B-1 0.20.

:>-:

CIRCULAR ADJUSTMENT SECTION (TYP.)

MANHOLE DIMENSION TABLE

ECCENTRIC CONE SECTION

DIAM.

..

...

..
..
..
..
..
..
...
..

MIN.
MIN.
WALL
BASE
THICKNESS THICKNESS

MAXIMUM
KNOCKOUT
SIZE

MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS

48"

4"

6"

36"

8"

54"

4.5"

8"

42"

8"

60"

5"

8"

48"

8"

~~
~~

bb
' '
Co~

PRECAST RISER SECTIONS

STEPS OR LADDER

...

.
..
...
.

24: 1

SLOPE

CHANNEL AND SHELF

REINFORCING STEEL (TYP.)


"O"RING

MANHOLE TYPE 1
STANDARD PLAN B-15.20-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

INTEGRAL BASE
PRECAST WITH RISER

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

MANHOLE RING AND COVER

NOTES
1. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum.
2. For pipe allowances, see Standard Plan B-1 0.20.

:>-:

CIRCULAR ADJUSTMENT SECTION (TYP.)

ECCENTRIC CONE SECTION

MANHOLE DIMENSION TABLE


DIAM.

..
..
..
..

PRECAST RISER SECTION

. I> .

. ..

..

I>.

"'' . .. .

..
.

.. !> ...

..

..

'()>. . . . . .

.. :

. I>

l:l~

. ..

. I> .

.. t>

... .,~ ..

I>

. I>

:b. ..

. I>

~ . ". ..,. ... i:.

~ ~

. .. . ..

I>

. .. "'
.. . .

'.

FLAT SLAB TOP

I>

I> .

."I> .. . ~ . ...

MAXIMUM
KNOCKOUT
SIZE

MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS

48", 54" OR 60"

~--~----~~~~----~~

MIN.
MIN.
WALL
BASE
THICKNESS THICKNESS

60"

5"

8"

48"

8"

72"

6"

8"

60"

12"

84"

8"

12"

72"

12"

96"

8"

12"

84"

12"

120"

10"

12"

96"

12"

144"

12"

12"

108"

12"

I>

..

\)'

..

. : . 1 - - - - - - - - - _ _ _S_E_E_T_A_B_L_E_ _ _ _ _ _ _--+t--11>,. '


I)'

..

. .

~ ". I>

..
..

...

'C>

..

. t>'

..

I>

....

. t>

. t>'

STEPS OR LADDER

".I>.

'i>

~ ". t:>

I>_ ...

I>

'

I>'

.I>'

. '

....

_...

..
.
".

I>

....

t:>

'"i:.

.....

24:1
SLOPE

. . ~-:--:-==::::=::::.---l_
...

12" MAX.

CHANNEL AND SHELF

. t> ....

\)':

"O"RING

REINFORCING STEEL (TYP.)

. :..:;Tfr~-~~. 4

MANHOLE TYPE 2

..

STANDARD PLAN B-15.40-01


SHEET 1 OF 1 SHEET

INTEGRAL BASE
PRECAST WITH RISER
(60" and 72" ONLY)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

NOTES
1. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum.
2. For pipe allowances, see Standard Plan B-1 0.20.

:>-:

3. No steps are required when height is 4' or less.

MANHOLE RING AND COVER

~ z

CIRCULAR ADJUSTMENT SECTION

:E

::2

MANHOLE DIMENSION TABLE

~ ~
......
. .. .. to . ..

..

..

..

... .

I>

..

I>

:c.. : ,;-

.
: ,;-

I>

..

c. . . C>

: 0, .....

I>

FLAT SLAB TOP

DIAM .

I> .....

..

MIN.
MIN.
WALL
BASE
THICKNESS THICKNESS

MAXIMUM
KNOCKOUT
SIZE

MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS

:b. .

..
...
. .
.

I>

......

..
.. .

:,; .

STEPS OR LADDER

..

I> .....

..

......

PRECAST RISER SECTIONS

48"

4"

6"

36"

8"

54"

4.5"

8"

42"

8"

60"

5"

8"

48"

8"

72"

6"

8"

60"

12"

84"

8"

12"

72"

12"

96"

8"

12"

84"

12"

120"

10"

12"

42"

12"

144"

12"

12"

108"

12"

..
:c. .
.. .
:b.

..
.....
I>. ...

CHANNEL AND SHELF

REINFORCING STEEL (TYP.)

"O"RING

GRAVEL BACKFILL FOR


PIPE ZONE BEDDING

SEPARATE BASE

INTEGRAL BASE

PRECAST

PRECAST WITH RISER

MANHOLE TYPE 3
STANDARD PLAN B-15.60-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

NOTES

1. Precast concrete cone sections may be eccentric or concentric.


2. Seepage port orientation varies among manufacturers.
3. When necessary, knockouts on precast cone, drywall base and
riser sections shall have a wall thickness of 1 1/2"
minimum and 2" maximum.
CIRCULAR FRAME (RING) - SEE
STANDARD PLAN B-30.70

CIRCULAR GRATE- SEE


STANDARD PLAN B-30.80

TOE OF DRYWELL SLOPE I


BOTTOM OF SWALE (TYP.)

TOE OF SWALE SLOPE I


BOTTOM OF SWALE

TOE OF SWALE SLOPE I


BOTTOM OF SWALE (TYP.)

GROUND LINE

ADJUSTMENT
SECTION (TYP.)

....1
....1

L.U

0
0

::::i

cr::
L.U
LL.

UNDISTURBED SOIL

DISTANCE VARIES

:>-:
Cil

!
0

SEE CONTRACT

:Z

NATIVE BACKFILL

:il

....N

UNDERGROUND DRAINAGE
GEOTEXTILE, MODERATE
SURVIVABILITY, CLASS A

1~..::;-.-

1
I
I
I

TOE OF DRYWELL SLOPE I


BOTTOM OF SWALE

:I:]
I

PLAN VIEW

I
I

ffi

GRAVEL BACKFILL
FOR DRYWELL

ii:

TOE OF SWALE SLOPE I


BOTTOM OF SWALE

il:]

_L _________

--------

:I:]

I
I
I

LIMIT OF EXCAVATION
1H : 2V SLOPE (MAX.)

~:I
I
I

SEEPAGE PORT (TYP.) SEE NOTE 2

I
I

il:]
:
il:]

~~

FOUR 6" DIAM. DRAIN HOLES (TYP.)


POSITIONED NOT TO INTERFERE
WITH REINFORCING BARS

~~

I
I
1
LT--r--r-~~T--r--r-,-

I II

DRYWELL TYPE 1
(FORSWALE)
STANDARD PLAN B-20.20-02

48" I.D.

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......
fll

------~s=~~TE~D~ES~IG~N~EN~G=IN=EE~R------

CUTAWAY ELEVATION VIEW

INTEGRAL BASE DETAIL

03-16-12
DATE

Washington State Department of Transportation

NOTES
1. Precast concrete cone sections may be eccentric or concentric.
2. Seepage port orientation varies among manufacturers.

CIRCULAR FRAME (RING) SEE STANDARD PLAN B-30.70

CIRCULAR GRATE- SEE


STANDARD PLAN B-30.80

3. Connect inlet pipe to structure using precast hole or core drilled hole.
FINISHED SURFACE

4. For depths over 16'- 2" use 72" x 8" Alternative Precast Footing .

....--------------"""""'l~Wf~gffft-1----t~-AniliiiTMFi;J:r---~ID'ff!im'ffr"" ~
\

ADJUSTMENT
SECTION (TYP.)

5. When necessary, knockouts on precast cone, drywell base and


riser sections shall have a wall thickness of 1 1/2" minimum
and 2" maximum.

VARIES

CONE SECTION
CRUSHED SURFACING
BASE COURSE

....1
....1

72"

NO PIPE JOINTS ALLOWED


IN GRAVEL BACKFILL ENVELOPE

0
0

::::i

z
c:::
w

LL.

1--~

I
I
I
I

INLET PIPESEE NOTE 3

:CY

I
I
I

iCY

~L

_________ ' ______ _

LIMIT OF EXCAVATION
1H : 2V SLOPE (MAX.)

I
I

:CY

I
I
I
I

I
I
I
I

GRAVEL BACKFILL
FOR DRYWELL

~:I

I
I
I

:CY
I
I
I

SEEPAGE PORT SEE NOTE 2

I
I

~--------------------~----~----~;--r--r
I
I
I

I
I
I

I
I
I

~._____I_ _________.I J

I
I

~:

ALTERNATIVE PRECAST
FOOTING DETAIL

I
I

~--T--,--

FOUR 6" DIAM. DRAIN HOLES (TYP.)


POSITIONED NOT TO INTERFERE
WITH REINFORCING BARS

I
N

.....

12"

~-----r---------~

UNDERGROUND DRAINAGE
GEOTEXTILE, MODERATE
SURVIVABILITY, CLASS A

~~

I,

~~----- $

48"

I.D. 48"

ALTERNATIVE FOOTING

INTEGRAL BASE

PRECAST

PRECAST WITH RISER

DRYWELL TYPE 2
(WITH PIPE INLET)
STANDARD PLAN B-20.40-03

CUTAWAY ELEVATION VIEW

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

INTEGRAL BASE DETAIL

STATE DESIGN ENGINEER

03-16-12
DATE

~ Washington State Department of Transportation

NOTES
1. Precast concrete cone sections may be eccentric or concentric.
2. Seepage port orientation varies among manufacturers.

CIRCULAR FRAME (RING)SEE STANDARD PLAN B-30.70

CIRCULAR GRATE- SEE


STANDARD PLAN B-30.80

3.

FINISHED SURFACE

4. When necessary, knockouts on precast cone, drywell base and


riser sections shall have a wall thickness of 1 1/2" minimum
and 2" maximum.

------------""""""'l~~m~~-~-----f~I""""Ji:n:il!iiTMFiN"T---~~~~"ffr" ~VARIES
\

For depths over 16'- 2" use 72" x 8" Alternative Precast Footing.

ADJUSTMENT
SECTION (TYP.)

72"
CONE SECTION
CRUSHED SURFACING
BASE COURSE

....1
....1

0
0

::::i

z
c:::
w

UNDERGROUND DRAINAGE
GEOTEXTILE, MODERATE
SURVIVABILITY, CLASS A

LL.

I
I
I
I
I

:CY

I
I
I

iCY

~L

48"

_________ ' ______ _

LIMIT OF EXCAVATION
1H : 2V SLOPE (MAX.)

I
I

:CY

I
I
I

I
I
I
I

GRAVEL BACKFILL
FOR DRYWELL

I
I
I

:CY
I
I
I

SEEPAGE PORT SEE NOTE 2

~:I

~~

ALTERNATIVE PRECAST
FOOTING DETAIL

~:

I
I

~--T--,---

FOUR 6" DIAM. DRAIN HOLES (TYP.)


POSITIONED NOT TO INTERFERE
WITH REINFORCING BARS

I
N

.....

12"

~.____I_ _ _IJ

I
I
I

I,

~----- $

~--------------------~----~---~--;--r--r
I
I
I
I
I
I
I
I
I

I
I

1/2"

~---r----------~

I.D. 48"

ALTERNATIVE FOOTING

INTEGRAL BASE

PRECAST

PRECAST WITH RISER

DRYWELL TYPE 3
(WITH AT-GRADE INLET)
STANDARD PLAN B-20.60-03

CUTAWAY ELEVATION VIEW

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


03-15-12
---------------------STATE DESIGN ENGINEER
DATE

INTEGRAL BASE DETAIL

.....

~ Washington State Department of Transportation

NOTES
::: 5 112"
1" R.

1.

This inlet requires the precast catch basin unit to be rotated 90 degrees so that the narrow
side is parallel to the curb line. When calculating offsets from curb to CL of the precast
catch basin, please note that the CL of the grate is not the CL of the precast catch basin.
See Section A

2.

The dimensions of the frame and hood may vary slightly among different manufacturers.
The Frame may have cast features intended to support a debris guard. Hood units may be
mounted inside or outside of the frame. The methods for fastening the safety bar I debris
guard rod to the hood may vary. The hood may include casting lugs. The top of the hood
may be cast with a pattern.

3.

Attach the hood to the frame with two 3/4" x 2" hex head bolts, nuts, and oversize washers.
The washers shall have diameters adequate to ensure full bearing across the slots.

4.

Bolt-down capability is required on all frames, grates and covers, unless specified in the
Contract. Provide two holes in the Frame that are vertically aligned with the grate slots.
The frame shall accept the 5/8" x 11 NC x 2" allen head cap screw by being tapped, or other
approved mechanism. The location of bolt-down holes varies among manufacturers.
See BOLT-DOWN DETAIL, Standard Plan B-30.10.

5.

Only ductile iron Vaned Grates shall be used. See Standard Plans B-30.30 and B-30.40
for grate details. Refer to Standard Specification 9-05.15(2) for additional requirements.

6.

This plan is intended to show the installation details of a manufactured product. This plan is not
intended to show the specific details necessary to fabricate the castings depicted in this drawing.

HOOD

...J
...J

112" MIN. -----VA->-

OPENING HEIGHT
4" MIN.

L.U

0
0

::::i

a:::

L.U

TOP OF GRATE

LL.

SEE NOTE 3
FRAME

SAFETY BAR I DEBRIS GUARD


518" MINIMUM DIAMETER STEEL
ROD (SEE NOTE 2)

DETAIL SECTION

CURB OR CURB AND GUTTER \

v.ct_

29" MIN.
FACE OF

I" ,.

MIN.
(TYP.)

. I.
I

i ct.
7" i3"i

GRATE-

SEE NOTE,

Jll~o~~~L
JJf
1'-

I
I

~
-

a.

~ ~

. ~ .~-~1

:. \0)

0.

...

~
.....

....
N

__.--::;;::::::::::>--~AF~TY

---

;;

FRAME

CATCH BASIN TYPE 1

40~~~-lE-~;~E) I<~

CATCH

mE 1L

3d.
(cil

..
. .

IDEBRIS GUARD

20" x 24" VANED GRATE

j "T k

HOLE OR SLOT FOR


ATTACHING HOOD (TYP.)

BAR

CATCH BASIN TYPE 1


SHOWN

.....

SEE NOTE 2
(TYP.)

/~;i3:'-

----),

---<>;:--\

...

\ S E (TYP.)
E NOTE<

__ .-------

1-.. .

...
,.

MATCH TOP OF HOOD


TO TOP OF CURB (TYP.)
HOOD

1ft

cu ~

20 114"

CATCH BASIN SEE NOTE 1

-------

~-~~-.. -.~.~-~<.!1~.....
:. -.~.. ...:.

COMBINATION INLET
STANDARD PLAN B-25.20-01

SHEET 1 OF 1 SHEET
TOP VIEW

FRAME DETAIL

SECTION

ISOMETRIC VIEW

COMBINATION INLET
FRAME, HOOD, AND VANED GRATE

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

03-15-12
DATE

~ Washington State Department of Transportation

NOTES
PIPE

ALLOWANCES

PIPE MATERIAL

FRAME AND VANED GRATE

MAXIMUM
INSIDE
DIAMETER

REINFORCED OR
PLAIN CONCRETE

12"

ALL METAL PIPE

15"

CPSSP *
(STD. SPEC. 9-05.20)

12"

SOLID WALL PVC


(STD. SPEC. 9-05.12(1))

15"

PROFILE WALL PVC


(STD. SPEC. 9-05.12(2))

15"

*CORRUGATED POLYETHYLENE
STORM SEWER PIPE

1. As acceptable alternatives to the rebar shown in the PRECAST BASE


SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 18". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate may be installed with the flange up or down. The
frame may be cast into the adjustment section.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.

16"

6. The opening shall be measured at the top of the precast base section.

OR 12"

7. All pickup holes shall be grouted full after the inlet has been placed.
ONE #3 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT

RECTANGULAR ADJUSTMENT SECTION

Lo

#3 BAR EACH CORNER


#3 BAR EACH SIDE
TOP AND BOTTOM

#3 BAR EACH CORNER


18" MIN.

CONCRETE INLET

-=----!---Y

STANDARD PLAN B-25.60-00


SHEET 1 OF 1 SHEET

ONE #3 BAR
ACROSS BOTTOM

PRECAST BASE SECTION

#3 BAR HOOP

APPROVED FOR PUBLICATION

SEE NOTE 1

ALTERNATIVE PRECAST BASE SECTION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

06-01-06
DATE

State Department of Transportation

29 1/4"

NOTES
1. This frame is designed to accommodate 20" x 24" grates or covers as shown
on Standard Plans B-30.20, B-30.30, B-30.40, and B-30.50.
2. Bolt-down capability is required on all frames, grates, and covers, unless
specified otherwise in the Contract. Provide 2 holes in the frame that are
vertically aligned with the grate or cover slots. The frame shall accept the
5/8" - 11 NC x 2" Allen head cap screw by being tapped, or other approved
mechanism. Location of bolt-down holes varies by manufacturer.
3. Refer to Standard Specification 9-05.15(2) for additional requirements.

BOLT-DOWN HOLE (TYP.)


- 5/8"- 11 NC (SEE /
DETAIL & NOTE 2)

co

RECESSED ALLEN
HEAD CAP SCREW
5/8" - 11 NC X 2"

'--

GRATE

LO

FRAME

I.

2 1/2"

DETAIL

.I

SECTION

BOLT-DOWN DETAIL
SEE NOTE2

TOP
FLANGE UPWARD
FRAME CAST INTO PRECAST
ADJUSTMENT SECTION - SEE
STANDARD PLAN B-30.90 FOR
ADJUSTMENT SECTION DETAILS

24 1/4"

RECTANGULAR FRAME
(REVERSIBLE)
STANDARD PLAN B-30.10-01
SECTION

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

ISOMETRIC VIEW
SHOWING THE VARIATIONS

STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

24"

NOTES

3"

1. Bolt-down capability is required on all frames, grates, and covers, unless


specified otherwise in the Contract. Provide 2 holes in the frame that are
vertically aligned with the grate or cover slots. The frame shall accept the
5/8" - 11 NC x 2" Allen head cap screw by being tapped, or other
approved mechanism. Location of bolt-down holes varies by manufacturer.

C\1

b
z
w
w

/-----------------------------

-,~----

en

~1"-------------------------------

2. Alternative reinforcing designs are acceptable in lieu of the rib design.

a::
BOLT-DOWN SLOT- SEE
DETAIL AND NOTE 1

3.

Refer to Standard Specification 9-05.15(2) for additional requirements.

4. For frame details, see Standard Plan B-30.10.

2 1/2" DIAM.

...... ---- ...


I'

0C\1

'
'

'

OLE

' \..-----------,..I"

_--

, ----------------------------- ...... "I

'
'

l . _____Jj~-~~-~~-- . -- ~~;~~i~.~-~-~-~:---- ': /------------ ~~--- -- ,j


'
'
:: ~~~<>
~---

5"

3 1/2"

~~~~~~
~

5/8"

1------.--t
t-- 3/4" DIAM. HOLE

~~~~~~~~
~

~/4"

~~~~~~~
~

~~~~~~~~~

1 1/4"

----,__,---- 1/2" DIAM. HANDLE

'-----------~~~~~~~~~

TOP

SECTION

SECTION

0
BOLT-DOWN SLOT DETAIL
SEE NOTE 1

~L-

1 1/2"
r3/4":

.I

~
~

or-

i
.

~j
SECTION

39" R. - SEE NOTE 2

RECTANGULAR SOLID
METAL COVER
STANDARD PLAN B-30.20-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

NOTES
1. Bolt-down capability is required on all frames, grates, and covers, unless specified
otherwise in the Contract. Provide 2 holes in the frame that are vertically aligned
with the grate or cover slots. The frame shall accept the 5/8" - 11 NC x 2" Allen
head cap screw by being tapped, or other approved mechanism. Location of boltdown holes varies by manufacturer.

I~MOl.:!l

2. For frame details, see Standard Plan B-30.10.

SLOT- SEE DETAIL


AND NOTE 1

3. Refer to Standard Specification 9-05.15(2) for additional requirements.

[e]

----,

J
io

'iii
::E

----,

io

<(

z
~
Cl
z

io

=>

----,

LL

1 1/4"

~
~
I~ FLOW

TOP

.~
l

SECTION

24"

7 OR 8 EQUAL SPACES

DIRECTION OF FLOW

r-~
SECTION

RECTANGULAR
VANED GRATE
STANDARD PLAN B-30.30-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

NOTES
1. Bolt-down capability is required on all frames, grates, and covers, unless
specified otherwise in the Contract. Provide 2 holes in the frame that are
vertically aligned with the grate or cover slots. The frame shall accept the
5/8" - 11 NC x 2" Allen head cap screw by being tapped, or other approved
mechanism. Location of bolt-down holes varies by manufacturer.

2. Refer to Standard Specification 9-05.15(2) for additional requirements.

SLOT - SEE DETAIL


AND NOTE 1

3. For frame details, see Standard Plan B-30.1 0.

----,

J
io

----,

io

w
:::!!
<(

z
~
0
z

io

=>

0
LL
-

----,

TOP

SECTION

1 1/4"

0
BOLT-DOWN SLOT DETAIL
SEE NOTE 1

24"

I"

4 EQUAL SPACES

"II"

4 EQUAL SPACES

r-~
SECTION

RECTANGULAR
BI-DIRECTIONAL
VANED GRATE
STANDARD PLAN B-30.40-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

NOTES
1. Bolt-down capability is required on all frames, grates, and covers, unless
specified otherwise in the Contract. Provide 2 holes in the frame that are
vertically aligned with the grate or cover slots. The frame shall accept the
5/8" - 11 NC x 2" Allen head cap screw by being tapped, or other approved
mechanism. Location of bolt-down holes varies by manufacturer.

24"

2. Refer to Standard Specification 9-05.15(2) for additional requirements.


3. For frame details, see Standard Plan B-30.10.
4. The thickness of the grate shall not exceed 1 5/8".

~ SLOT- SEE DETAIL


AND NOTE 1

1" OPENING (TYP.)

~
1 1/4"

b
N

~
<(

z
~
0
z

:::::>

u..
BOLT-DOWN SLOT DETAIL
SEE NOTE 1

TOP

RECTANGULAR
HERRINGBONE GRATE
STANDARD PLAN B-30.50-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

DRILL AND TAP 5/8"- 11NC


HOLE FOR 1 1/2" x 5/8"
STAINLESS STEEL SOCKET
HEAD CAP SCREW (TYP.)

1. The gasket and groove may be in the seat (frame) or in the underside of
the cover. The gasket may be "T" shaped in section. The groove may be
cast or machined.
2. Bolt-down capability is required on all frames, grates, and covers, unless
specified otherwise in the Contract. Provide 3 holes in the frame that are
vertically aligned with the grate or cover slots. The frame shall accept the
5/8"- 1 NC x 2" Allen head cap screw by being tapped, or other approved
mechanism. Location of bolt down holes varies by manufacturer.

1 3/8"

NOTES

-------~ ~

3. For bolt-down manhole ring and covers that are not designated "Watertight,"
the neoprene gasket, groove, and washer are not required.

3 1/8"

1/2" (TYP.)

RING PLAN

5. In lieu of blind pick notch for manhole covers, a single 1" pick hole is
acceptable. Hole location and number of holes may vary by manufacturer.

27 5/8"
BLIND PICK NOTCH

4. Washer shall be neoprene (Detaii"B").

6. Alternative reinforcing designs are acceptable in lieu of the rib design.

26 3/8"

DETAIL"A"

1..

7. For clarity, the vertical scale of the Cover Section has been exaggerated,
it is 1.5 times the horizontal scale (1H:1.5V).

=
.....

~=+-----------+-

~~~1!_____2_:_:~_. ____~ 1
34 1/8"

RING SECTION

SKID GROOVE
PATTERN- SEE
DETAIL

RING SECTION

SEE DETAIL "A"

TOP

SKID GROOVE PATTERN


DETAIL

SEE DETAIL "A"

TOP

BOTTOM

1 7/16"

Pl

WASHER
(SEE NOTES)

1)16"

SPECIFY LETTERING

1
COVER PLAN

COVER PLAN
SEE DETAIL "B"
SEE DETAIL "A"

SEE DETAIL "A"

1/2" (MIN.)
1/4" DOVETAIL GROOVE
WITH NEOPRENE GASKET
(SEE NOTES)

CIRCULAR FRAME (RING}


AND COVER

BOLT-DOWN I WATERTIGHT

DETAIL "B"

STANDARD PLAN B-30.70-03


COVER SECTION

COVER SECTION

(SEE NOTE 7)

(SEE NOTE 7)

STANDARD

BOLT-DOWN /WATERTIGHT

TYPE1

TYPE2

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

ISOMETRIC VIEW

STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

NOTES

1. For use with Circular Frames (rings) detailed in Standard Plan B-30. 70.
2. Slotted Manhole Covers are intended for use with Drywells only. See
Standard Plans B-20.20 and B-20.60.

( /10
I;

I/ !;
/; !;
I/ !;

//!_____ --- -- ",]

/;

"'-----------------

((

((

(1

II
II
II
II
11 I
11
11
11
11
11

1
1
1
1
1
1
1
1
1
1

I
I
I
I
I
I
I
I
I
I

II

0
1l

I
I

~~~~~~--~~--~~~--~

I
I

L:c---=--=--=----=--=--=---=--=--=------=-- -'"
r:::---=--=--=-

(1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
LC __-::_-::_-::_ __-::_-::_-::_ _-::_-::_-::_ __-::_-::_-::_ __ I

,- --=--=--=- - --=--=--=- --=--=--=- - --=--=--=- - ( '


I
I
I
I
I
I

ISOMETRIC VIEW

f
SECTION

0
CIRCULAR GRATE

~L-...J::....:~~~~~'-L--..1~ ~ ~ ~ ~ ~L-...JL..:~~~~~~y ~

STANDARD PLAN B-30.80-00


SHEET 1 OF 1 SHEET

~~

~~
SECTION

~~

APPROVED FOR PUBLICATION

Harold J. Peterfeso

_....:_:=:_-=;,;ST;AT;E~DE~S~IGiNEi.N~GI;;;;NE'<'ER;;-----

fJ'I Washington State Department o


....

06-08-06
DATE

Transportation

NOTE
Ladder rungs for manholes and catch basins shall
meet the requirements of AASHTO M 199.

#f3 BARS @ 7" SPACING

1:
~r

20" X 24",
24" DIAM., 48" DIAM.
OR 54" DIAM. HOLE

I I
II

LJ

-~

12-;;-r-

__._I

: ____.____.__ L _ L _ L _

L-

.I
12"[1YP.)

J1]~~

I I
II

2"(TYP.)

't

12" MIN.

O"l

l=====j

::!!:

LJ

STEP

_l

L l1"MIN.
2 1/2" MAX.

84" or 96" FLAT SLAB TOP

TYPICAL ORIENTATION
FOR ACCESS AND STEPS

PREFABRICATED LADDER

#5 BARS @ 6" SPACING

J~OR1T
24" MIN.

20" X 24",
24" DIAM., 48" DIAM.
OR 54" DIAM. HOLE

2" (TYP.)
I ......___.____._

I
ONE #3 BAR HOOP FOR 6"
TWO #3 BAR HOOPS FOR 12"

_l
l1"MIN.
2 1/2" MAX.

RECTANGULAR ADJUSTMENT SECTION

72" FLAT SLAB TOP

As an acceptable alternative to rebar, wire mesh having a


minimum area of 0.12 square inches per foot may be used
for adjustment sections.

#4 BARS @ 6" SPACING

ECCENTRIC CONE SECTION

20" X 24" OR
24" DIAM. HOLE

_L_

1Ir-_l_

2" (TYP.)

=co~r-__._---r-:----,---:____.___._--.-----h
.~

oi U

MISCELLANEOUS DETAILS
FOR
DRAINAGE STRUCTURES
STANDARD PLAN B-30.90-01

SHEET 1 OF 1 SHEET
ONE #3 BAR HOOP

UL1"MIN.
2 1/2" MAX.

48", 54", or 60" FLAT SLAB TOP

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

CIRCULAR ADJUSTMENT SECTION

.....

STATE DESIGN ENGINEER

09-20-07
DATE

fJ'I Washington State Department of Transportation

~:-=-:~1

NOTES

I
I
I

54"

1. The Steel Angles shall be set so that each bearing bar of prefabricated grate shall have full
bearing on both ends. The finished top of concrete shall be even with the grate surface.

42"
I
I
I
I

2. All exposed concrete shall be finished with a 1/2" radius.

_____!

I
I
I
I

3. The grade line of the top inside of any pipe shall enter no lower than the grade line of the
top inside of the outlet pipe.

1/
1/2" 1t 4" STUDS OR
5 1/2" )( 1 1/2" )( 1/4"
STEEL ANCHORS
(3 BOTH ENDS)

4. Pipes may enter through the knockouts on any side at any reasonable angle, provided the
outside of the pipe can be contained between two opposite walls.

--------

to

0..:

f...

------- -

t_

to

47 1/4"

3 318".1

5. See contract for type of grate specified. See Standard Plan B-40.20 and B-40.40 for grate
details.

6"
3"

--------

_...J

~
.....
.....

1.. 318"

~~

TOP VIEW
1/2" 1t 4" STUDS OR
5 1/2" )( 1 1/2" )( 1/4"
STEEL ANCHORS
(3 BOTH ENDS)
GRATE- SEE NOTE 5

I_T

DETAIL

_____________ _

I
I
I
I
I
I
I
I
I
I

SECTION

LJ

N
.....
I
----------+-~~--~w

....1

Ill
<(

it:

INVERT OF
0UTLET PIPE

7/

~,

''
''
''
''

''
''
''

''

GRATE INLET TYPE 1


(CAST-IN-PLACE)
STANDARD PLAN B-35.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SILTING BASIN

....

Harold J. Peterfeso

SIDE VIEW
ISOMETRIC VIEW

STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

---.------ c
I
I
I
I
I

-~-----------------------

II
I
I
I

UNIT"H"

f-- __ 1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

\ _ - - - - - - - - - - - - _j

-,-'
1
1
I
1 I
I
I
I
I
I
I

---.----- c I

I
I
I
I

c _ , - - - - - - - - - - - - - - - - - - - - - - -, -

f-

~---1

I
I

I
I

I
I

I
I

I
I

UNITS "J" & "K"


~-~-----------------------+--1
I
I
AS REQUIRED
I
I
4"MIN.

_ _,_,1

H--

----H

I
I
I
I

-1
I
I

::!!:

lo

-,-- '

c.:

lo

11, - - - - - - - - - - - - - ~1
I
I
I
I
I
I
__ L - - - - - - - - - - - - _ j - I
I
I
I

~- ~--------------+---I

~
::!!:

-~------------

26"

....1

::c
~

ll)

TOP VIEW
54"

::::>
~

(.)

0:::

37"
---.------ cI

I
I
I
I

-~------------

1
1

-,--'
1
1

1 r------------~

I
I
I
I
I
I
f- __ L - - - - - - - - - - - - _ j - -

_ _,_,1

H--

----H

I
I
I
I

-1
I

5 1/2" MIN.

io

io

MIN.

5 1/2" MIN.

4 SPACES@ APPROX. 12 1/2"

3 SPACES@ APPROX. 11"

54"

37"

SECTION

ONE PIECE BASE

11

5 1/2" MIN.
4 SPACES@ APPROX. 12 1/2"

2"

5 1/2" MIN.
2"

26"

TWO PIECE BASE

ONE PIECE BASE

MAXIMUM
INSIDE
DIAMETER

REINFORCED OR
PLAIN CONCRETE

18"

ALL METAL PIPE

21"

CPSSP *
(STD. SPEC. 9-05.20)

18"

GRATE INLET TYPE 2

SOLID WALL PVC


(STD. SPEC. 9-05.12(1))

21"

STANDARD PLAN B-35.40-00

PROFILE WALL PVC


(STD. SPEC. 9-05.12(2))

21"

SHEET 1 OF 2 SHEETS

3 SPACES@ APPROX. 11"

54"

SECTION

PIPE ALLOWANCES

PIPE MATERIAL

SECTION

a.

37"

SECTION

TWO PIECE BASE

*CORRUGATED POLYETHYLENE
STORM SEWER PIPE

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

54"

54"

.r-+----------------------,_-h

lr-~------ -------------1-\r-+---------.-

(-------------------- ---,-+-11---rn----'----,l

ll~

42"

~
I~

L i

~~

!
I

I
!

rnl

l-1--------------------' ----+./

1 ----

114"x51~"x11~.~~L/j ~

5"

(3 BOTH ENDS)

\. ________________________

5"

UNITS "J" & "K"

jJ

3 3/B".

~~~~~
00

STEEL ANGLES

_...J
~

~D
----'\V"

~~

~ ~

471/4"

NOTES

1.

The Steel Angles shall be set so that each bearing bar of prefabricated grate shall have full bearing
on both ends. The finished top of concrete shall be even with the grate surface.

2.

Top of inlet grate shall be placed at ground level to present an unobstructed ditch or median section .

3.

All exposed concrete edges shall be finished with a 1/2" radius.

4.

Pipes may enter through the knockouts on any side at any reasonable angle, provided the outside of
the pipe can be contained between two opposite walls.

5.

The flow line of the outlet pipe shall be 18" minimum above the inside bottom of the inlet structure.

6.

The grade line of the top inside of any inlet pipe shall enter no lower than the grade line of the top
inside of the outlet pipe.

7.

Unit "H" and optional extension units "J" and "K" shall be grouted in place to the satisfaction of the
Engineer.

8.

All pickup holes shall be grouted full after the basin has been placed.

9.

See contract for type of grate specified. See Standard Plan B-40.20 and B-40.40 for grate details.
6 1/4"

UNIT "H"

GRATE

GRATE- SEE NOTE 9

SECTION

2 1/2"

UNIT "J"

------

....-

SECTION

UNIT "H"

1SECTION

SECTION

UNIT "K"

LOCATION

MARK

QTY.

SIZE

LENGTH

DESCRIPTION

CD

~
.--

CD

BOTTOM SLAB AND SIDE WALL

5'- 9"

BOTTOM SLAB AND SIDE WALL

12'- 5"

BOTTOM SLAB AND SIDE WALL

7'- 2"

BOTTOM SLAB AND SIDE WALL

2'- 9"

STRAIGHT

WALL

9'- 1"

HOOP

CD 2- 9"

SIDE WALL

14'- 6"

HOOP

(j)

UNIT H

14'- 2"

HOOP

UNIT J

14'- 2"

HOOP

4'-2"
@4'-2"
@4'-2"
@2'-9"

UNIT K

14'- 2"

HOOP

UNIT K

0'- 9"

STRAIGHT

@)

SIDE WALL

2'- 8"

STRAIGHT

BOTTOM SLAB AND SIDE WALL

7'- 5"

BOTTOM SLAB AND SIDE WALL

6'- 0"

SIDE WALL

14'- 6"

@
@

10"

888@

HOOP

----r
~~~~
ad..

eo m

3"

4"1~_l_

(j)

GRATE

;;7:~

4'-2"
4'- 2"
@4'-1"
@4'-2"

(j)

I.

UNIT "H"

~~
.-.--

&,.-<or--r-' ' ' ' '


;....~;....;....;....

6"

BENDING DIAGRAM
(ALL DIMENSIONS ARE OUT TO OUT)

BAR LIST

7"

GRATE INLET TYPE 2


STANDARD PLAN B-35.40-00

5 1/2" )( 1 1/2" )( 1/4"


STEEL ANGLES
(3 BOTH ENDS)

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

DETAIL0

STATE DESIGN ENGINEER

fJ'I Washington

06-08-06
DATE

State Department of Transportation

46 3/4"

1 3/8"

46 3/4"

1 3/8"

ELEVEN EQUAL SPACES

3 1/2" >< 3/8" STEEL


PLATE (TYP.)

1 3/8"

>
.....
(')

ELEVEN EQUAL SPACES

(> /
1 318"

3 1/2"

><

3/8" STE EL
DES)

\ : E (BOTH Sl

Ill
CJ)

CJ)

(..)

(..)

<1:

D..

~
.....

"""

CJ)

~
.....

...J

<1:
:::>

"""

zw

ct

===::!

CJ)

3 1/2" )( 3/4"
STEEL PLATES

...J

<1:
:::>

0
w
w

__j

>
u:::

1-

TOP

CROSS BARS - 3/8" ROUND, OR


RECTANGULAR OR HEXAGONAL
BAR OF EQUIVALENT AREA.

END

====

~~

TOP

SIDE

END

CROSS BARS - 318" ROUND, OR


RECTANGULAR OR HEXAGONAL
BAR OF EQUIVALENT AREA.

SIDE

GRATE "A"

GRATE "B"

(APPROXIMATE WEIGHT 215 LBS)

(APPROXIMATE WEIGHT 215 LBS)

WELDED GRATES
FOR GRATE INLET
STANDARD PLAN B-40.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

ISOMETRIC

ISOMETRIC

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

RECESSED ALLEN
HEAD CAP SCREW
5/8" - 11 NC X 2"

__l_

Lo

GRATE

t
t

c:::i

GRATE

NOTES
1. The Contract may specify a rotated inlet installation. Orient the Grates
in the Frame so they intercept flow.
2. When bolt-down grates are specified in the Contract, provide two slots
in the grate that are centered with the holes in the frame. Location of
bolt-down slots varies among different manufacturers.
3.

Refer to Standard Specification 9-05.15(2) for additional requirements.

4.

Frame and Grates shall be Ductile Iron.

(-t)

FRAME

SECTION

SLOT

21"

~j

I"

.,....

HOLE

"I

7 EQUAL SPACES

BOLT-DOWN DETAILS

.... FLOW

SEE NOTE 2

r-~
SECTION

GRATE

0
.....,

0
.....,

NORMAL INSTALLATION

1 1/2"

1-

.......

~-HOLE

BOLT-DOW
(TYP.)
- 5/8
11 NC, SEE
DETAIL & NOTE 2

~-

0'

I
TOP

46 3/4"

SECTION

---------~'

42_1/4"

1---1_ _ _ _

t!

FRAME AND DUAL


VANED GRATES
FOR GRATE INLET
STANDARD PLAN B-40.40-01
SHEET 1 OF 1 SHEET

ROTATED INSTALLATION

FRAME

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

SECTION

ISOMETRIC VIEWS
SEE NOTE 1

.....

fll

STATE DESIGN ENGINEER

06-16-10
DATE

Washington State Department of Transportation

NOTES

SEE CONTRACT FOR


BACKSLOPE DETAILS
TYPE 3 GRATE SHOWN

1. The top of the inlet shall be placed at ground level to present an unobstructed ditch or median section.

DITCH LINE

2.

Bevel or round exposed concrete edges 1/2".

3. Pipes may enter through the knockouts at any reasonable angle provided
the outside of the pipe can be contained within the knockout provided.
4. The grade line of the lowest inlet pipe shall enter the structure at an elevation equal to or higher than the grade line of the outlet pipe.

5. All pickup holes shall be grouted full after the inlet has been placed.
SECTION ON DITCH LINE

6.

DIKE INSTALLATION FOR PREFERRED SLOPE

The steel angles shall be set so that each bearing bar of the grate shall
have full seating on both ends. The finished top of concrete shall be
even with the grate surface. For grates, see Standard Plan B-50-20.

36"

7. The amount, type, and grade of reinforcing steel is the responsibility of


18"

the manufacturer.
1/4
12"

1/4

TYP.

8. The inside wall taper for form removal shall not result in any wall section

84"

thinner than 6" except in pipe knockout areas.

9. Precast inlets shall be marked with the manufacturer's identification on


I

cc

_,

il

cc

_,

the inside of the structure in some readily accessible location.

_,

-1111

TOP

;-__~DITCH

4" X 3" X 1/2" X 35 1/4"


STEEL ANGLE

I
-

4" X 3" X 3/8"


STEEL PLATE

('")

1
-TACKWELD~3
TO ANGLE

1
I

""

1/2" DIAM. x 4" STEEL STUD PLACE ALONG SUPPORT AS


SHOWN FOR ANGLES

--~

Jill

c"

\I

""

c"

c"

1/4

5 1/2" X 1" X 1/4"


STEEL ANGLE

ANCHOR STUD OPTION

END

PLAN

END

GRATE SUPPORT DETAIL


(FOUR SUPPORTS REQUIRED)

::::: 42"

GRATE SUPPORT (TYP.)


-SEE DETAIL

6" MIN.

II

II

LJ

2" MIN.

DROP INLET TYPE 1


STANDARD PLAN B-45.20-00
SHEET 1 OF 1 SHEET

39"

SECTION

SECTION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

ISOMETRIC
(SHOWN WITH TYPE 1 GRATE)

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

10'- 0"

NOTES

C"

C"

I'
II II

~-

~-

~-

'I

c'

I
-

c'

c'

1111
I

r--

1. The top of the inlet shall be placed at ground level to present an unobstructed ditch or median section.

I
C"

't.:ITCH

- -

'~

5. All pickup holes shall be grouted full after the inlet has been placed.

,1111
""

Pipes may enter through the knockouts at any reasonable angle provided
the outside of the pipe can be contained within the knockout provided.

4. The grade line of the lowest inlet pipe shall enter the structure at an elevation equal to or higher than the grade line of the outlet pipe.

I
'~

3.
b

'~

Bevel or round exposed concrete edges 1/2".

II II
II

2.

""

""

"

c"

c"

c"

6. The steel angles shall be set so that each bearing bar of the grate shall
have full seating on both ends. The finished top of concrete shall be
even with the grate surface. For grates, see Standard Plan B-50.20.
7. The amount, type, and grade of reinforcing steel is the responsibility of
the manufacturer.

PLAN

GRATE SUPPORT (TYP.)


-SEE DETAIL

8. The inside wall taper for form removal shall not result in any wall section
thinner than 6" except in pipe knockout areas.
9.

Precast inlets shall be marked with the manufacturer's identification on


the inside of the structure in some readily accessible location.

2" MIN.

30"

SECTION

36"

SECTION

18"
1/4
,-1.:.:.../4-'---++-< TYP.

12"

TOP
4" X 3" X 1/2" X 35 1/4"
STEEL ANGLE
4" X 3" X 3/8"
STEEL PLATE

TOANGLE
:
-TACKWELD~3

5 1/2" X 1" X 1/4"

---

STEEL ANGLE

DROP INLET TYPE 2

1/2" DIAM. x 4" STEEL STUD PLACE ALONG SUPPORT AS


SHOWN FOR ANGLES

STANDARD PLAN B-45.40-00

1/4

SHEET 1 OF 1 SHEET

ANCHOR STUD OPTION

END

APPROVED FOR PUBLICATION

END

....

Harold J. Peterfeso

GRATE SUPPORT DETAIL

ISOMETRIC

(SIX SUPPORTS REQUIRED)

(SHOWN WITH TYPE 2 GRATE)

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

~ c=~~=,=.~)~~==C=)~~==C=)~~=c=~,=.~~=c_=~)~~==~=-)-~-~-~
OPTIONAL 1" MAX. VENT HOLES~
ON BOTTOM FOR GALVANIZING

I
I

:::!!:

3 1/2" X 1/2" X 34 1/2"


STEEL PLATE (TYP.) \

:
~

3 1/2" X 1/2" X 34 1/2"


STEEL PLATE (TYP.}

OPTIONAL1" MAX.

VENT HOLES
ON BOTTOM FO R GALVANIZING

.....
(;
-

C>

I'
-f- 1,-'-!

3 1/2" X 1/2" X 34 1/2"

(=)

STEELPLATE~.) \~==c~t)======C=)======C=)============C_=~)======ct~)==~
I

3 1/2" i

FIVE SPACES

3 1/2"

34 1/2"

TYPE3
3 1/2" X 3 1/2" X 5/16" X 33 1/4"
STRUCTURAL TUBING (TYP.)
I

2" (TYP.)

.I

1 ..

34 1/2"
I

,+,
~r)

5 1/4"

,_,

,_,

,~,

,~,

THREE SPACES

TYPE2

,+,
\r)

GRIND TOP AND BOTTOM


FLUSH AFTER WELDING

TYP.

SECTION
3 1/2" X 1/2" X 33 1/4"
STEEL PLATE (TYP.}

5 1/4"

34 1/2"

TYPE 1

TYP.

SECTION
3 1/2" X 3 1/2" X 5/16" X 33 1/4"
STRUCTURAL TUBING (TYP.)

GRIND TOP AND BOTTOM


FLUSH AFTER WELDING

TYP.

SECTION

GRATES FOR DROP INLET

STANDARD PLAN B-50.20-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

ISOMETRICS

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

TRENCH WIDTH
(SEE NOTE 3)

NOTES

PIPE ZONE BACKFILL


(SEE NOTE 1)

w
0

GRAVEL BACKFILL FOR


PIPE ZONE BEDDING
(SEE NOTE 2)

85% O.D.
(SEE NOTE 4)

1.

See Standard Specifications Section 7-08.3(3) for Pipe Zone Backfill.

2.

See Standard Specifications Section 9-03.12(3) for Gravel Backfill for Pipe Zone Bedding.

3.

See Standard Specifications Section 2-09.4 for Measurement of Trench Width.

4.

For sanitary sewer installation, concrete pipe shall be bedded to spring line.

w
c..

a:

15% O.D.

TRENCH WIDTH
(SEE NOTE 3)

I~

CONCRETE AND DUCTILE IRON PIPE

~I
Co

TRENCH WIDTH
(SEE NOTE 3)

PIPE ZONE BACKFILL


(SEE NOTE 1)

w
1:2

CJ)

GRAVEL BACKFILL FOR


PIPE ZONE BEDDING
(SEE NOTE 2)

Ill
CXl

GRAVEL BACKFILL FOR


PIPE ZONE BEDDING
(SEE NOTE 2)

c..

a:
15% RISE

FOUNDATION LEVEL~

Co

2w

ci

c..

a:

PIPE ARCHES

THERMOPLASTIC PIPE
CLEARANCE BETWEEN PIPES
FOR MULTIPLE INSTALLATIONS

I.

TRENCH WIDTH
(SEE NOTE 3)

PIPE ZONE BACKFILL


(SEE NOTE 1)

PIPE

-I

CIRCULAR PIPE
(DIAMETER)

Co
~
0

GRAVEL BACKFILL FOR


PIPE ZONE BEDDING
(SEE NOTE 2)

Ill

~
0

Ill

FOUNDATION LEVEL

l_

ci

ci

w
c..

a:

PIPE ARCH
(SPAN)
METAL ONLY

SIZE

MINIMUM
DISTANCE
BETWEEN
BARRELS

12" to 24"

12"

30" to 96"

DIAM./2

102" to 180"

48"

18" to 36"

12"

43" to 142"

SPAN /3

148" to 200"

48"

PIPE ZONE BEDDING


AND BACKFILL
STANDARD PLAN B-55.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Co

....

Harold J. Peterfeso

METAL PIPE

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

NOTES

I"

1. The Concrete Collar width shall be one half of the outside pipe diameter of the largest pipe.
The minimum Concrete Collar width shall be 12". Concrete Collars may be used with all pipe
materials and diameters. The Concrete Collar option shall only be used to extend existing
pipes.

COUAR WIDTI<
1
STEEL WELDED WIRE FABRIC - SEE NOTE 2

CAST-IN-PLACE CONCRETE COLLAR

2. Steel Welded Wire Fabric shall be in accordance with Standard Specification 9-07.7. Install
two wraps for size 6 )( 6 W1.4 )( W1.4 (10 Gage} Steel Welded Wire Fabric or one wrap for
any of the following sizes:
6 )( 6 W2.1 )( W2.1 (8 Gage}
6 )( 6 W2.9 )( W2.9 (6 Gage}
4 )( 4 W2.9 )( W2.9 (6 Gage}
4 )( 4 W4.0 )( W4.0 (4 Gage}
3. When a Coupling Band connection requires attachment to the bell end of a concrete pipe, the
bell end of the pipe shall be removed before the connection is installed.
4. Increase the outside diameter of the metal pipe to match the outside diameter of the concrete
pipe by installing 12" wide rubber gaskets, thickness as required (Coupling Band only}. The
rubber gaskets shall be in accordance with Standard Specification 9-04.4(3}.
5.

Use a flat Type K Coupling Band. Type K Coupling Bands with dimples are not allowed for
the installation detail shown. The Coupling Band option shall only be used for extending existing pipes that have an inside diameter of 36" or less.

CONCRETE COLLAR OPTION

24"
CORRUGATED METAL PIPE

I I
I I
II
II

CONCRETE PIPE - SEE NOTE 3

I
I
I
I

,------------------------------------1

RUBBER GASKETS - SEE NOTE 4


TYPE "K'' COUPLING BAND - SEE NOTE 5

24" WIDE, 1" THICK RUBBER GASKET


IN ACCORDANCE WITH STD. SPEC. 9-04.4(3}

CONNECTION DETAILS FOR


DISSIMILAR CULVERT PIPE
STANDARD PLAN B-60.20-00
SHEET 1 OF 1 SHEET

COUPLING BAND OPTION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

REFORMED PIPE ENDS

COUPLING BAND DIMENSION TABLE

(ALL DIMENSIONS ARE IN INCHES)


BAND
TYPE

BAND LAP NOT SHOWN


FOR CLARITY (TYP.)

TYPED

TYPED

ANNULAR CORRUGATED BAND

BAND ANGLE CONNECTOR DETAIL

CORRUGATION
PITCH x DEPTH

PIPE
DIAM.

MIN.

GASKET
TYPE

2 2/3 )( 1/2
OR
3 )( 1

12-84

12

SLEEVE

REFORMED TO 90- 144


2 2/3 )( 1/2

24

SLEEVE

REFORMED TO
2 2/3 )( 1/2

3 )( 1
...J
UJ
UJ

1C/)

REFORMED PIPE ENDS

2 2/3 )( 1/2
OR
3 )( 1

12-84 10 1/2

0-RING

12-48

2 3/4

BUTYL

12-48

12

54-84

24

3 )( 1

54- 144

24

2 2/3 )( 1/2

12-72

12

3 )( 1

36-60

12

REFORMED TO
2 2/3 )( 1/2

w
J
K

2 2/3 )( 1/2
2 2/3 )( 1/2

:::?!

TYPEF

TYPE F

TYPEF

SEMI-CORRUGATED BAND

BAND ANGLE CONNECTOR DETAIL

BAR & STRAP CONNECTOR DETAIL

REFORMED TO 66- 108


2 2/3 )( 1/2

=>

:::?!

=>

<(

REFORMED PIPE ENDS


WITH FLANGES

2 2/3

1/2

2 2/3

1/2

...J

*
*

3 )( 1

SLEEVE

SLEEVE

24

12-48 10 1/2
12-48

12

54-84

24

54-96

24

0-RING
SLEEVE

PIPE ARCH ONLY

TYPEJ
TYPEJ

BAND ANGLE CONNECTOR DETAIL

FLANGE BAND
NEW PIPE EXTENSION
WITH REFORMED END
OR HELICAL END

EXISTING PIPE WITH


HELICAL END

1/2" )( 6" BOLT (TYP.)

~~;;~

COUPLING BANDS FOR


CORRUGATED METAL PIPE
STANDARD PLAN B-60.40-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

TYPEK

TYPEK

TYPEK

FLAT BAND OR DIMPLE BAND

BAND ANGLE CONNECTOR DETAIL

DOUBLE BAR & STRAP CONNECTOR DETAIL

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

NOTES

rn
z

6'- 8"

0:::

Ill

1. Span and rise dimensions are nominal and are measured to the inside crests of corrugations.

SPAN

=35"

....1
....1

2. Allowable heights of cover shall be within the limits indicated in the table included hereon .
Minimums and maximums are shown.

iii

SYMMETRICAL
ABOUT

3.

Unless indicated otherwise a 10" depth (over the inside crests of corrugatons) of earth shall
be placed in the invert of the Structural Plate Underpass, Design 1, for its full width and length.
The earth shall consist of naturally occurring materials available in the vicinity of the structural
plate underpass installation. See Standard Specification 7-03.3(4).

4.

Designed for H-20 live load and maximum allowable soil pressure of 6 Kips per square foot.

R =59 3/8"

= w
....
rn

r:..o::

HEIGHT OF
CORNER
PLATE

LO
C')

R = 26 1/4"

MITER PARALLEL TO
EMBANKMENT SLOPE

INVERT TREATMENT

1-

R =56 3/8"

11..:5
oa.
1-0:::

::cw

SECTION

Qti
wo

:co

6'- 10"
R

SPAN

=35"

INVERT TREATMENT
-SEE NOTE 3
LENGTH IN A MULTPLE OF 2'
SYMMETRICAL
ABOUT

SIDE VIEW- PLACEMENT

R = 87"

=
w
Nrn
~ 0::

ALLOWABLE HEIGHTS OF COVER


<
C')
HEIGHT OF
CORNER
PLATE

12 GAGE THICK
CORRUGATED METAL
SPAN

RISE

COVER

R =25"
14 1/2"

INVERT TREATMENT
R

=64"

46 1/4"

MIN.

MAX.

ANIMAL UNDERPASS

6'- 8"

7' - 1"

4'

26'

STANDARD PLAN B-65.20-01

6'- 10"

8'- 2"

5'

25'

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SECTION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

04126112
DATE

~ Washington State Department of Transportation

NOTES
Span and rise dimensions are measured to the inside crests of
corrugations and may vary slightly depending on manufacturer.

HEADWALL - BOTH ENDS

EMBANKMENT SLOPE
MITER PARALLEL TO
EMBANKMENT SLOPE
u..W

ol-

1-:5
::cD..

(!)0:::

-w
wz
::Ca:::

C/)

a:

II 0
<((.)

SYMMETRICAL
ABOUT

't
INVERT TREATMENT
-SEE STD. SPEC. 7-03.3(4)
LENGTH IN A MULTIPLE OF 2'

SPAN

SIDE VIEW- PLACEMENT

SECTION

INVERT TREATMENT

ALLOWABLE HEIGHTS OF COVER


DIMENSIONS
CORRUGATED METAL THICKNESS
ANGLES (DEGREES)
SPAN

RADII (INCHES)

12GAGE

RISE

10GAGE

SGAGE

AT

AS

AC

AB

RT

RS

RC

RB

(INCHES)

MIN.

MAX.

MIN.

MAX.

MIN.

MAX.

12'- 2"

11'- 0"

52

42

65

21

68

93

38

134

44

3'

14'

3'

20'

3'

26'

12'-11"

11'- 3"

52

41

65

21

73

95

38

144

45

3'

13'

3'

19'

3'

25'

13'- 2"

11'-11"

52

43

65

19

73

103

38

159

43

4'

13'

4'

19'

4'

24'

13'- 10"

12'- 3"

53

41

65

20

77

108

38

164

45

4'

12'

4'

18'

4'

23'

14'- 1"

12'- 10"

53

44

65

18

77

115

38

182

43

4'

12'

4'

18'

4'

23'

14'- 6"

13'- 6"

56

38

65

21

78

131

38

174

46

4'

11'

4'

17'

4'

22'

14'- 10"

14'- 0"

55

41

65

19

79

136

38

192

44

4'

11'

4'

17'

4'

21'

15'- 6"

14'- 4"

55

40

65

19

84

138

38

201

46

4'

11'

4'

16'

4'

20'

15'- 9"

15'- 1"

56

41

65

18

83

150

38

212

45

16'

4'

20'

15'- 5"

57

39

65

19

86

157

38

215

47

4'

15'

4'

19'

16'- 5"

16'- 1"

58

42

65

14

88

158

38

271

41

4'

15'

4'

19'

16'- 9"

16'- 3"

58

40

65

17

89

167

38

247

43

4'

15'

4'

19'

17' - 3"

17'- 0"

57

38

65

19

90

174

47

215

55

4'

14'

4'

18'

STANDARD PLAN B-65.40-00

18'- 4"

16'-11"

55

42

65

18

99

157

47

249

53

4'

13'

4'

18'

SHEET 1 OF 1 SHEET

19'- 2"

17'- 2"

54

43

65

18

105

156

47

264

53

53

46

65

16

107

158

47

297

50

4'

17'

20'- 4"

17'- 10"

53

46

65

16

113

156

47

314

52

----

17'

17'- 7"

-------

4'

19'- 6"

-------------------

4'

16'- 4"

-------------------

4'

16'

EQUIPMENT UNDERPASS

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

06-01-06
DATE

State Department of Transportation

NOTES

END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE STD SPEC 7-02 3(1))

~~

1.

The culvert ends shall be beveled to match the embankment or ditch


slope and shall not be beveled flatter than 4H:1V. When slopes are
between 4H:1V and 6H:1V, shape the slope in the vicintiy of the
culvert end to ensure that no part of the culvert protrudes more than
4" above the ground line.

2.

Field cutting of culvert ends is permitted when approved by the Engineer.


All field-cut culvert pipe shall be treated with treatment as shown in the
Standard Specifications or General Special Provisions.

4"MAX.

THERMOPLASTIC PIPE

--------------------------------------------------------------------------------------

~ 4" MAX.

FOR CULVERTS 30"'


DIAMETER OR LESS

CONCRETE PIPE

END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE STD. SPEC. 7-02.3(1))

BEVELED END SECTIONS


STANDARD PLAN B-70.20-00

~4"MAX.
METAL PIPE

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

PIPE ARCH
DIMENSION
(INCHES)
SPAN
17
21
24
28
35
42
49
57
64
71
77

THICKNESS
(INCHES)

RISE
13
15
18
20
24
29

STEEL
0.064
0.064
0.064
0.064
0.079
0.079
0.109
0.109
0.138
0.109
0.138
0.109
0.138
0.109
0.138
0.109
0.138

33
38
43
47
52
57

83

ALUM.
0.060
0.060
0.060
0.075
0.075
0.105
0.105
0.105
0.105
0.135

------

NOTES

PIPE

ARCH
DIMENSIONS (INCHES)

TOL.
1"

MAX.

TOL.
1"

TOL.
1 1/2"

TOL.
2"

TOL.
2"

6
6
6
6
6
8
9
12
12
12
12
12

19
23
28
32

30
36
42
48

40
46
52

39
46

60
75

53
63
70
77
77
77

85
90
102
114
126
138

7
7

9
10
12
14
16
18
21
26

8
9
10
12
13
18
18
18
18
18

30
33
36
39

THICKNESS
(INCHES)
STEEL
0.064
0.064
0.064
0.064
0.064
0.079
0.079
0.109
0.109
0.109
0.109
0.138
0.109
0.138
0.109
0.138
0.109
0.138
0.109
0.138

12
15
18
21
24
30
36
42
48
54
60
66
72
78
84

A
ALUM.
0.060
0.060
0.060
0.060
0.075
0.075
0.105
0.105
0.105
-----

TOL.
1"

-------------------

6
7
8
9
10
12
14
16
18
18
18
18
18
18
18

MAX.

TOL.
1"

TOL.
1 1/2"

TOL.
2"

TOL.
2"

6
8
10
12
13
16
19
22
27
30
33
36
39
42
45

6
6
6
6
6
8
9
11
12
12
12
12
12
12
12

21
26
31

24

34
40
46
52

DIAM.
OR
SPAN ..

36
41
51
60
69
78
84
87
87
87
87
87

30
36
42
48
60
72
84
90
102
114
120
126
132
138

1-1-

zz
w-

::2:0
>-D..

<(CJ)

D..J:

w
D..

ii:
REINFORCED EDGE
(SEE NOTE 6)

58
70
94
106
112
122
134
142
146
152
158

1
1
1
1
1
2
2
3
3
3
3
3

58
70
85
103
114
130
146
152
158

PIPE
DIMENSIONS (INCHES)
PIPE
DIAM.
(INCHES)

END
SECTION
SKIRT
SLOPE
(H:V)

SKIRT

PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.

2
2
2
2
2
2
2
2
2
2
1
1

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
1/2

:
:
:
:
:
:
:
:
:
:
:
:

END
SECTION
SLOPE
(H:V)

1
1
1
1
1
1
1
1
1
1
1
1

1. The diameter of the end section of Design B shall match the inside
diameter of the concrete pipe.
2.

3.

6.

The reinforced edges of the following size End Sections shall be


supplemented with galvanized steel stiffener angles:
60" thru 72" diameter pipe ............................... 2" x 2" x 1/4" angle

Skirt sections shall be made in one piece for round pipe with a
diameter of 12" to 24" inclusive and for pipe arches with a rise
of 13" to 20" inclusive. Skirt sections for larger sizes of pipes may
be multiple pieces in conformance with the tabulated values shown.
Design A end sections for 42" thru 84" diameter and 49" x 33" thru
83" x 57" arch with annular corrugations and all helically corrugated
pipe arch include one foot of pipe length as a connector section.
The connector section shall be attached to the end section by welds,
rivets or bolts and shall be the same thickness as the end section.

78" and 84" diameter pipe, and


77" x 52" & 83" x 57" pipe arch ........... 2 1/2" x 2 1/2" x 1/4" angle
The above galvanized angles shall be attached by 3/8" galvanized
nuts and bolts.
7.

Galvanized steel angle reinforcement will be placed under the


center panel seams on the 72" thru 84" diam. pipe and 77" x 52"
& 83" x 57" pipe arch End Sections.

8.

4.

Design C may be used in lieu of Design A for all metal pipe sizes
except as noted. Coupling bands may be any acceptable type for
the pipe specified.

5.

Multiple panel skirts shall have 2" lap seams tightly joined by 3/8"
stainless steel rivets or galvanized bolts on 6" max. centers.

As an alternative to the connector lug and threaded rod used on


12" thru 24" culvert pipe, the attachment may be made with a
1" wide strap, 16 gage galvanized steel fastened with a 1/2" diam.,
6" long galvanized bolt and one squarehead nut.

PIPE

1- 1-

1
1
1
1
1
2
2
2
2
2
3
3
3
3
3

PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.
PC.

2
2
2
2
2
2
2
2
2
2
1
1
1
1
1

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
1/2
1/3
1/4
1/6

:
:
:
:
:
:
:
:
:
:
:
:
:
:
:

zwz

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

:!:a:
~ (/)

PIPE

D..

CONNECTORLUG
(SEE NOTES)

TH READED ROD

:c
o

CONNECTOR
SECTION

w 1-

PIPE

c..

THREADED ROD

1-

END SECTION

END SECTION
FOR 12" THRU 24" PIPE
AND 17" x 13" THRU
28" x 20" PIPE ARCH WITH
ANNULAR END CORRUGATIONS

FOR 30" THRU 84" PIPE


AND 35" x 24" THRU
83" x 57" PIPE ARCH WITH
ANNULAR END CORRUGATIONS

FOR 42" THRU 84" PIPE AND


49" x 33" THRU 83" x 57" PIPE ARCH
WITH ANNULAR END CORRUGATIONS, AND ALL
HELICAL END CORRUGATED PIPE AND PIPE ARCH

TYPE1

TYPE2

TYPE3

DESIGN A

CONNECTION TO METAL PIPE

SPAN

1" MINIMUM LAP


AFTER EXPANSION

CONCRETE PIPE

1-

~
REINFORCED EDGE
(SEE NOTE 6)

GALVANIZED
STEEL OR
ALUMINUM SKIRT

EXPANDER LUG
TOE PLATE
EXTENSION

TOE PLATE
EXTENSION

DESIGN B
CONNECTION TO CONCRETE PIPE
INLET END ONLY

PIPE & PIPE ARCH - PLAN

PIPE- ELEVATION

PIPE ARCH- ELEVATION


1-1-

PIPE

SECTION

~~~

TOE PLATE EXTENSION -WHEN REQUIRED;


GALVANIZED STEEL OR ALUMINUM, SAME
GAGE AS SKIRT, LAPPED 2", FASTENED W/
3/8" S.S. ORAL. RIVETS OR GALVANIZED
BOLTS ON 12" MAX. CENTERS.

PIPE

PIPE COUPLING BAND, SHOP BOLTED TO FLARED


END SECTION WITH 3/8" BOLTS AT 6" ON CENTER
MAXIMUM OR EQUIVALENT RIVETED OR WELDED
CONNECTION. FOR USE WITH ALL SIZES OF PIPE
AND PIPE ARCH WITH ANNULAR ENDS.

zz
w-

::i!:a:
~(/)

FLARED END SECTIONS

D..J:

Wl-

~0

D.. I-

STANDARD PLAN B-70.60-00


SHEET 1 OF 1 SHEET

END SECTION

APPROVED FOR PUBLICATION

DESIGN C
CONNECTION TO METAL OR CONCRETE PIPE
OUTLET ONLY

Harold J. Peterfeso
- .
------;S:=TA:-=TE=-:D:-=ES""IG""Nc=EN::::G:::-:IN=EE:::-R--...

fJ'I Washington

06-01-06
DATE

State Department of Transportation

FILL SLOPE - VARIABLE

0::

w
Cli--

#4 BARS EQUALLy SPACED


16" MAX. CENTER TO CENTER

I"

NOTES

WZ

w
I-

z
w

ow
<((.)
0..0
(/)I-

~------------------~

~0::

1. The variable dimension indicated for the height of step for step mitered
pipes shall conform to the manufacturers recommendations unless specified differently on the plans or in the Special Provisions.

COMMERCIAL
CONCRETE

...JW

<(1-

:JZ

w ow
wo

2. Reinforcing steel shall have 1 1/2" min. clear cover to all concrete surfaces.

(/)

3.

~
:;;

~~

ca::i;

;;!;~
ANCHOR BOLTS ~----- EQUALLY SPACED, 24"
MAX. CENTER TO CENTER
(SEE NOTE 3)

Headwalls for concrete culvert pipe may omit anchor bolt attachment.

4. When steel pipe safety bars ar used, headwall thickness shall be increased
to 8".

S+S/2

STRUCTURAL PLATE PIPE ARCHES AND UNDERPASSES


FILL SLOPE
-VARIABLE

#4 BARS EQUALLY SPACED

FILL SLOPE
-VARIABLE

16" MAX. CENTER TO CENTER

#4 BARS EQUALLY SPACED


16" MAX. CENTER TO CENTER
0::
w
01-

ANCHOR BOLTS EQUALLY SPACED, 24"


MAX. CENTER TO CENTER
(SEE NOTE 3)

wz

OW

<((.)

COMMERCIAL
CONCRETE

c..o

C/)1-

~0::

....IW

<(1::JZ

COMMERCIAL
CONCRETE

ow
wo

ANCHOR BOLTS EQUALLY SPACED, 24"


MAX. CENTER TO CENTER
(SEE NOTE 3)
D+D/2
D+D/2

FULL MITERED PIPE

STEP MITERED PIPE

PIPES AND STRUCTURAL PLATE PIPES

D+D/2 OR S+S/2
FILL SLOPE
6"

HEADWALLS FOR CULVERT


PIPE AND UNDERPASS
STANDARD PLAN B-75.20-01

ANCHOR BOLT (TYP.)


- SEE DETAIL & NOTE 3

SHEET 1 OF 1 SHEET
PIPE

APPROVED FOR PUBLICATION


3/4" BOLT

SECTION

ANCHOR BOLT DETAIL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-10-08
DATE

Washington State Department of Transportation

HEADWALL <t_
SEE NOTE 5

NOTCH BOTIOM OF
CULVERT PIPE TO ALLOW
ANCHOR/SOCKET
PLACEMENT {TYP.)

-~

STEEL PLATE
-SEE DETAIL

FIELD CUT CULVERT TO


MATCH BLOCKOUT IN HEADWALL

18"

CULVERT DIAM.

NUMBER OF BARS
REQUIRED

UP TO 36"

NONE

42" - 60"

66" - 90"

96" -

120"

.. !.. 3"I

3/4" RESIN BONDED


ANCHOR {TYP.)SEE NOTE 4

NOTES
1. Sockets shall be 3" extra strong steel pipe (3 1/2" O.D.). Sockets must be the
proper angle and height so that safety bars are parallel with headwall and side
slope, and are easily removable.
2.

Safety Bars shall be 4" extra strong steel pipe (4 1/2" O.D.), or 4 1/2" O.D. (.250"
wall thickness) steel tubing. Length (20' maximum) shall be the minimum required to achieve Resin Bonded Anchor placement in full depth concrete. When
multiple bars are required (see table) place bars at equal spacing (30" max.).

3.

Bevel culvert pipe to match side slope.

4.

Resin bonded anchors shall be 7" in length (5" embedment).

5.

Centerline of headwall shall be normal to roadway centerline.

TOP VIEW

CULVERT IS PERPENDICULAR TO ROADWAY

1" X 4" SLOT WITH


2" HOLE AT BOTTOM
{TYP.)

d---+----+-2" {TYP.)
4" {TYP.)

4.5" DEEP
BLOCKOUT

2" {TYP.)
8" X 24" X 5/8"
STEEL PLATE

SAFETY BAR
PLACE RESIN BONDED ANCHORS
IN FULL DEPTH CONCRETE {TYP.)
-SEE NOTE 4

9"

9"

SLOPE TO MATCH
SIDE SLOPE
HEADWALLCOMMERCIAL CONCRETE

STEEL PLATE DETAIL

STEEL PLATESEE DETAIL

CULVERT PIPE
OR PIPE ARCH SEE NOTE 3

TOP VIEW

CULVERT IS SKEWED TO ROADWAY

SAFETY BARSEE NOTE 2

CUT AND WELD

ISOMETRICCUTAWAY

24"

ISOMETRIC VIEW

SOCKET SHALL EXTEND


INTO SAFETY BAR 4"

3/4" DIAM. x 16" THREADED ROD CENTERED


THROUGH PIPE, SECURED WITH NUTS; OR
3/4" x 6" ANCHOR STUDS WELDED TO PIPE.
SPACING SHALL BE 8" FROM TOP AND 8"
FROM BOTIOM OF CONCRETE {TYP.)

TYPE 1 SAFETY BARS FOR


STEPPED CULVERT PIPE
OR PIPE ARCH
STANDARD PLAN B-75.50-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


06-10-08
----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

FINISHED
GROUND
Dl4

NOTES

1. D

Dl4

SEE NOTE 1

CULVERT CROWN
FIELD CUT PIPE BEVEL

\:

:j

"" No"' 2

1J

~~1Vor~ 2

~
Y

II

2. The distance between the safety bars, and between the top bar and the culvert
crown, shall be equal spaces of no more than 24". The distance may vary 1"
between bars to facilitate placement.
3. Slope shall match Side Slope; 6H:1V preferred, not steeper than 4H:1V.

CULVERT INVERT

SEE NOTE 3

~:~

= Inside Diameter of Culvert Pipe, or Pipe Arch Span Width, 36" maximum.

~~:
/"J

L"---

318" )( 4" )( 10"


STEEL PLATE

718" DIAM. HOLE

SIDE VIEW

FRONT VIEW
3" )( 3" )( 5116"
STRUCTURAL TUBING

10" (TYP.)
1 112"
(TYP.)

3 112"

4"

:[ryp~

(TYP.)

5 314" )( 314" DIAM. THREADED


ROD, 4" EMBEDMENT WITH
HEX HEAD NUT (TYP.)

1" MAX

I>

6
-~

D- 2"

""-

y6~ \

SEE NOTE 1

SECTION

"'
RESIN BONDED
ANCHOR (TYP.)

\_

10" (TYP.)
1 112"
(TYP.)

3 112"

4"

:[rypj

(TYP.)

SAFETY BAR (TYP.)

314" MAX. (TYP.)

....t:::::

-.-----

C___[

HEADWALL- SEE
STD. PLAN B-75.20
FOR DETAILS

3 112" )( 3 112" BLOCKOUT (TYP.)


- FIELD- CUT CULVERT TO MATCH
BLOCKOUT IN HEADWALL

INSTALL RESIN BONDED


ANCHOR (TYP.)

5 314" )( 314" DIAM. THREADED


ROD, 4" EMBEDMENT WITH
HEX HEAD NUT (TYP.)
~

CULVERT PIPE
OR PIPE ARCH

314" MAX. (TYP.)

ISOMETRIC VIEW

I>

D- 2"
SEE NOTE 1
INSTALL RESIN BONDED
ANCHOR (TYP.)

SECTION

TYPE 2 SAFETY BARS FOR


CULVERT PIPE OR PIPE
ARCH (ON CROSS ROAD)
STANDARD PLAN B-75.60-00
SHEET 1 OF 1 SHEET

1" MAX.

APPROVED FOR PUBLICATION


VARIES

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

NOTES
EDGE OF END SECTION
SHEET ROLLED SNUGLY
AGAINST STEEL ROD

7/16" DIAM. MIN. GALVANIZED


STEEL ROD OR NO. 4
GALVANIZED REINFORCING BAR

1. All pipes or pipe arches shall be attached as shown in CONNECTOR DETAIL.

FLATTEN END, THEN BEND OUTSIDE


4" TO MATCH END SECTION SIDES

1REINFORCED EDGE
SECTION

5 1/4"

-I

9/16"

2. When a Toe Plate Extension is required, it shall be the same gage as the End Section.
The dimensions shall be 8" high, and 6" less than the overall width. Install centered,
and lapped 2"; fasten with 3/8" x 3/4" galvanized bolts on 12" maximum centers.
3. Cross Drainage Bar and Safety Bars shall be 3" Schedule 40 galvanized steel pipe.
Cross Drainage Bars shall be placed a maximum 30" apart.

1" SLOTS (TYP.}

SAFETY BAR END TREATMENT DETAIL

4. Slotted holes for safety bar attachment shall be provided on end sections.
5. Number of Safety Bars required will vary depending upon the length of the end section.
METAL END SECTIONS FOR CIRCULAR PIPES

REINFORCED EDGE - FULL


LENGTH OF END SECTION
(SEE SECTION}

PIPE
DIAM.
(INCHES)

48" MAX.

{-J-

66
80
86
92

L
SLOPE 4:1
104
128
152
176

L
SLOPE 6:1
156
192
228
264

98

200

300

GAGE

OVERALL
WIDTH

0.109
0.109
0.109
0.109

12
12
12
12

12
16
16
16

9
12
12
12

0.109

12

16

12

42
48
54
60
66

1/2" DIAM. CARRIAGE


HEAD BOLTS (TYP.}

~TI-T

DIMENSIONS
(INCHES}

INCHES

36
42
48
54
60

CROSS DRAINAGE BAR


DETAIL

MINIMUM
THICKNESS

METAL END SECTIONS FOR ARCHED PIPES

EQUIV.
DIAM.
(INCHES)

SIDE VIEW

30
36
42
48
54
60
72

SAFETY BARS (TYP.}


-SEE NOTE 5
CROSS DRAINAGE BAR
-SEE DETAIL

SAFETY BAR END TREATMENT


-SEE DETAIL

PIPE ARCH
DIMENSIONS

MINIMUM
THICKNESS

SPAN RISE
(IN.)
(IN.)

INCHES GAGE

*35
42
49
57
64
71
83

24
29
33
38
43
47
57

0.079
0.109
0.109
0.109
0.109
0.109
0.109

14
12
12
12
12
12
12

DIMENSIONS
(INCHES)

12
12
16
16
16
16
16

9 1*41
9
48
12
55
12
63
12
70
12
77
12
89

OVERALL
WIDTH
65
72
87
95
102
109
121

L
SLOPE 4:1
56
76
92
112
132
148
188

L
SLOPE 6:1
84
114
138
168
198
222
282

*SAFETY BARS ARE INSTALLED ON END SECTION WHEN SPAN IS GREATER THAN 36"

3/8

'--+f---- (TYP.}
3/8" DIAM. HEX
HEAD BOLTS (TYP.}

30" AND LARGER END SECTIONS MAY


BE MULTIPLE PANELS. SEAMS SHALL
BE LAPPED 2" AND JOINED W/ 3/8" x 3/4"
BOLTS ON 6" MAX. CTRS.
1/2" DIAM. THREADED ROD OVER
TOP OF END SECTION. SIDE LUGS
TO BE BOLTED TO END SECTION

REINFORCED EDGE
(SEE SECTION}

TAPERED END SECTION


WITH TYPE 3 SAFETY BARS

1/2" DIAM. CARRIAGE


HEAD BOLTS (TYP.}

STANDARD PLAN B-80.20-00

TOE PLATE EXTENSION


-WHEN REQUIRED
(SEE NOTE 2)

SHEET 1 OF 1 SHEET

SIDE LUG

APPROVED FOR PUBLICATION


END SECTION

ISOMETRIC VIEW

CROSS DRAINAGE STRUCTURE

....

Harold J. Peterfeso

TOP VIEW

CONNECTOR DETAIL

STATE DESIGN ENGINEER

fJ'I Washington

06-08-06
DATE

State Department of Transportation

NOTES
REINFORCED EDGE - FULL
LENGTH OF END SECTION
(SEE SECTION)

1. As an alternative connection on 15" through 24" pipe, a 1" wide strap of 16 gage or 12
gage galvanized steel, fastened with a 1/2" diam., 6" long galvanized bolt and square
head nut, may be used.

~
c

SAFETY BAR (TYP.)


SEE NOTE 2

2.

Number of safety bars required will vary depending upon the length of the end section.

D..

[[

'1_

METAL END SECTIONS FOR CIRCULAR PIPES

{_l_

1/2" DIAM. CARRIAGE


HEAD BOLTS (TYP.)

~TI~

GAGE

OVERALL
WIDTH

15
18
21
24
30
36
42
48
54
60

.064
.064
.064
.064
.109
.109
.109
.109
.109
.109

16
16
16
16
12
12
12
12
12
12

8
8
8
8
12
12
16
16
16
16

6
6
6
6
9
9
12
12
12
12

21
24
27
30
36
42
48

37
40
43
46
60
66
80
86
92
98

7/16" DIAM. MIN. GALVANIZED


STEEL ROD OR NO. 4
GALVANIZED REINFORCING BAR

1..

5 1/4"

.. I

9/16"

DIMENSIONS
(INCHES)

INCHES

SIDE VIEW

EDGE OF END SECTION


SHEET ROLLED SNUGLY
AGAINST STEEL ROD

MINIMUM
THICKNESS

PIPE
DIAM.
(INCHES)

FLATTEN END, THEN BEND OUTSIDE


4" TO MATCH END SECTION SIDES

x 1" SLOTS (TYP.)

54
60
66

L
SLOPE 4:1
20
32
44
56
80
104
128
152
176
200

L
SLOPE 6:1
30
48
66

84
120
156
192
228
264
300

METAL END SECTIONS FOR ARCHED PIPES


EQUIV.
DIAM.
(INCHES)

SAFETY BAR END TREATMENT DETAIL


REINFORCED EDGE
SECTION

18
21
24
30
36
42
48
54
60
72

SAFETY BAR END TREATMENT


-SEE DETAIL
SAFETY BAR (TYP.)

30" AND LARGER END SECTIONS MAY BE


MULTIPLE PANELS. SEAMS SHALL BE
LAPPED 2" AND JOINED W/ 3/8" x 3/4"
BOLTS ON 6" MAX. CTRS.

PIPE ARCH
DIMENSIONS

MINIMUM
THICKNESS

DIMENSIONS
(INCHES)

SPAN
(IN.)

RISE
(IN.)

INCHES

GAGE

OVERALL
WIDTH

21
24
28
35
42
49
57
64
71
83

15
18
20
24
29
33
38
43
47
57

.064
.064
.064
.079
.109
.109
.109
.109
.109
.109

16
16
16
14
12
12
12
12
12
12

8
8
8
12
12
16
16
16
16
16

6
6
6
9
9
12
12
12
12
12

27
30
34
41
48
55
63
70

43
46
50
65
72
87
95
102
109
121

77
89

L
SLOPE 4:1
20
32
40
56
76
92
112
132
148
188

L
SLOPE 6:1
30
48
60
84
114
138
168
198
222
282

318" DIAM. HEX


HEAD BOLTS (TYP.)
1/2" DIAM. THREADED ROD OVER
TOP OF END SECTION. SIDE LUGS
TO BE BOLTED TO END SECTION

1/2" DIAM. CARRIAGE


HEAD BOLTS (TYP.)

REINFORCED EDGE
(SEE SECTION)

TAPERED END SECTION


WITH TYPE 4 SAFETY BARS
(ON CROSS ROAD)
STANDARD PLAN B-80.40-00

SIDE LUG
END SECTION

TOE PLATE EXTENSION- WHEN REQUIRED;


SAME GAGE AS END SECTION, 6" LESS THAN
OVERALL WIDTH; CENTERED, 2" LAP, FASTEN
W/3/8" x 3/4" GALV. BOLTS ON 12" MAX. CTRS.

SHEET 1 OF 1 SHEET
TOP VIEW

CONNECTOR DETAIL
ISOMETRIC VIEW

CROSS ROAD DRAINAGE STRUCTURE

APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

------~S~~~TE~D~ES=IG~NE~NG~IN~E=ER~----

fJ'I Washington

06-01-06
DATE

State Department of Transportation

24"
DUMMY JOINT WITH 3/16"
x 1 1/2" JOINT MATERIAL

:Z

WIRE MESH
TEMPORARY CAP AT EDGE OF
RIGHT OF WAY, UNLESS OTHERWISE
DRECTED IN CONTRACT

vo

RfW LINE

t>

....
= ~
(0:::!!:

t>

\1

t>

\1

t>
\1

t>
\1
r-~

t>

--,

]-----[
I

,\lr

,\lr

24

4" DRAIN PIPE

,1

,\lr

6"

12"

(TYP.)
,\rr

,\rr

b
b

SECTION

,\r/

\\r/
'

'

b
~

'

b
~

4" DRAIN PIPE

WIRE MESH REINFORCEMENT


6 x 6 W4.0 x W4.0 (4 GAGE}
4 X 4 W2.9 X W2.9 (6 GAGE}
(SEE STD. SPEC. 9-07.7}
1/2" MINIMUM COVER

CONCRETE
SIDEWALK

DUMMY JOINT

_j

PLANTING
STRIP

'

b
~

'

\\1/

,\lr

,\rr

-------1

\\i(

\\r I

,\lr

,\lr

,\rr

w
c..
0__.

,\rr

CJ)

CJ)

,\lr

:Z

,\lr
,\rr

?}!.
\\ 1(

ROADWAY

ROADWAY

,\lr
,\lr

PLANTING
STRIP

CONCRETE CURB
-TYPE MAY VARY

,\rr

~
,\lr

INVERT OF DRAIN
SHALL BE AT OR
ABOVE GUTTER LINE

ISOMETRIC

RESIDENTIAL STORM
DRAIN, UNDER SIDEWALK

------'-------i

STANDARD PLAN B-82.20-00


SHEET 1 OF 1 SHEET
(REINFORCEMENT NOT SHOWN)

PLAN

APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

Cl

0::

LL.

~
<(

en

::::i

:;...:
CD

PLUG

6" SINGLE BRANCH WYE


FOR TWO CONNECTIONS

Cl

6"WYE
39"
6" SINGLE BRANCH WYE
FOR TWO CONNECTIONS

x 39" MIN.

6"WYE

6"WYE
6"WYE
6"

x (SEWER SIZE) TEE

....1

CD
<(

0:::

6" SEWER PIPE

6" SEWER PIPE

SECTION

COMMERCIAL CONCRETE

l1----ll)

11

11

....1

~-~-=-==-~-~~~~-~-~-~-=-==-=-+~~~-~~=~~~~~

CD
<(

I
I
I
I
I

FOR SANITARY SEWER USE

0:::

~-=-~-=-,+~1F=~~~-~~~~~~~~~~~~=4=~~~
6" x (SEWER SIZE) TEE

4"TYP.
39" MIN.

ELEVATION
SECTION

0
VERTICAL CONNECTION
STANDARD PLAN B-85.10-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-10-08
DATE

Washington State Department of Transportation

NOTES

1. Install sewer saddle with gasket and stainless steel clamps


for connection to existing sewers. Install wye or tee sewer
fitting with gaskets for new sewer installations.
2. Mark location of sewer stub in accordance with Contracting
Agency requirements.

4" OR 6" DIAM. SEWER PIPE


(SEE CONTRACl)
LESS THAN 90"

CAP

4" OR 6" DIAM. SEWER PIPE


(SEE CONTRACl)
CAP

SEE NOTE 2
SEE NOTE 1

SEE NOTE 1

45" ELBOW

PROPERTY LINE /

WVE BRANCH

SEE NOTE 2

TEE BRANCH

PROPERTY LINE
SEWER MAIN

SEWER MAIN

PLAN VIEW

PLAN VIEW

FOR SANITARY SEWER USE

______

~_,

2% MIN., 45" MAX.

ELEVATION VIEW

ELEVATION VIEW

WYE CONNECTION

TEE CONNECTION

SIDE SEWER CONNECTION


STANDARD PLAN B-85.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

45 BEND

4" OR 6" SEWER PIPE


(SEE CONTRACn

24" x 24" x 24" CONCRETE BLOCK


OR CONTROLLED DENSITY FILL

I>

l>

I>

l>

I>

l>

FOR SANITARY SEWER USE

~i;j~.

~iil~fii~;;

I>

oiS~~~
g"'~i!i~

I>

u~~~
.,~~i!!"

b
b
I>

I>

(!;

~ [l;i!i~
1iil!!~~:!l

I>

l>

!:lcsl!!~i!i

I>

~Uh

I>

45 BEND

tl)o

l>
b

alQ::o,

.,~ii'l!'!i;!

I>

I>

~>-

~~~~~
o::l..:c

TEE

~~~~~

~~iij~~

I>

~~~~~

I>

SEWER MAIN

I>

l>

STANDING SIDE SEWER


CONNECTION

I>

b
b

I>

I>

STANDARD PLAN B-85.30-00

.l>

I>

l>

SHEET 1 OF 1 SHEET
I>

APPROVED FOR PUBLICATION

I>

I>

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-01-06
DATE

fJ'I Washington State Department of Transportation

J:

(.)

1/2"

(.)

:iii

3/4" RAISED SQUARES,


3/4" APART, 1/8" HIGH

<X:
24"

:>-:

Ill

Cl

6
6

----0

FIBER JOINT
PACKING

8"

45" BEND

1/2" WIDE, 1/8" HIGH


RAISED BORDER

1"

PLAN

10"

FOR SANITARY SEWER USE

7"
7 3/4"
8"
15"

8 INCH SEWER CLEAN-OUT


SECTION

STANDARD PLAN B-85.40-00


SHEET 1 OF 1 SHEET

CAST IRON RING AND COVER

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

06-08-06
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

fJ'I Washington State

SECTION

SECTION

MORTAR DAM OR PLUG AS


REQUIRED BY ENGINEER

ONE LENGTH OF DUCTILE


IRON PIPE (CLASS 50) TO
SOLID BEARING WHEN SPAN
IS MORE THAN 48"

TYPICAL
MANHOLE

D.I.P. TEE
CLEARANCE 2"

ONE LENGTH OF DUCTILE IRON


PIPE (CLASS 50) TO SOLID
BEARING WHEN SPAN IS MORE
THAN 48"

TYPICAL
MANHOLE

1/2 BLIND FLANGE AS DAM

FLEXIBLE JOINT

FLEXIBLE JOINT

All pipe, except ductile iron pipe,


shall be concrete encased.

BACKFILL WITH
COMPACTED MATERIAL
AS DIRECTED BY ENGINEER

BACKFILL WITH COMPACTED


MATERIAL AS DIRECTED
BY ENGINEER<:!--

~1"MIN.

". l>.

COMMERCIAL CONCRETE POURED IN PLACE

..

t>'

/)

/)

.....
..

FOR SANITARY SEWER USE

t> .....
.

t>'

. . rl+,:----++:1;. ".

COMMERCIAL CONCRETE BLOCK POURED IN PLACE

. ..
.

t> . . . . .

t>

..

TYPICAL MANHOLE
FOUNDATION
CONSTRUCTION

TYPICAL MANHOLE
FOUNDATION CONSTRUCTION

D.I.P. 90" BEND


CLEARANCE 2"

ELEVATION

ELEVATION

DUCTILE IRON
DROP CONNECTION

CONCRETE ENCASED
DROP CONNECTION

DROP CONNECTIONS
STANDARD PLAN B-85.50-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
fll

-----,s=rA=TE=-:D=E=SIG""N""EN:-c:Gc:ciN=EE"'"R---

06-10-08
DATE

Washington State Department of Transportation

NOTES

1. Steel tie rods to be heavily coated with asphalt after installation.


2. Restrained joints may be substituted for tie rods.
3. Surface of ground within 36" of hydrant shall be smooth.

VALVE BOX

VALVE BOX
WATER MAIN
WATER MAIN

TWO 314" DIAM.


TIE RODS

TWO 314" DIAM.


TIE RODS

PLAN

PLAN

36" MIN.
(UNLESS DIRECTED
OTHERWISE)

36" MIN.
(UNLESS DIRECTED
OTHERWISE)
PROPERTY

PROPERTY
LINE

LINE~

36" MIN.

FACE OF CURB

36" MIN.

FACE OF CURB

VALVE BOX AND LID


-CAST IRON

LENGTH OF LOWER
BARREL TO SUIT
TRENCH DEPTH

LENGTH OF LOWER
BARREL TO SUIT
TRENCH DEPTH
15 POUND
ASPHALTIC FELT

VALVE BOX

15 POUND
ASP HALTIC FELT

VARIES

VARIES
WATER
MAIN

WATER MAIN
6 CUBIC FEET MIN.
GRAVEL POCKET

6 CUBIC FEET MIN.


GRAVEL POCKET

6" PIPE
12" X 12" X 4" MIN.
CONCRETE BLOCK
MECHANICAL JOINT
WITH TIE ROD LUGS

ELEVATION

6" GATE VALVE (FLANGE


BY MECHANICAL JOINT)

HUB AND FLANGE CASTING


12" X 12" X 4" MIN.
CONCRETE BLOCK

AUXILLARY GATE VALVE

ELEVATION

HYDRANT SETTING
TYPES A AND B
STANDARD PLAN B-90.10-00
SHEET 1 OF 1 SHEET

TYPE A

TYPEB

APPROVED FOR PUBLICATION

Harold J. Peterfeso
- .
------;S:=TA:-=TE=-:D:-=ES""IG""Nc=EN::::G:::-:IN=EE:::-R--...

06-08-06
DATE

fJ'I Washington State Department of Transportation

NOTES

PROPERTY LINE \

------ _\------

CONCRETE THRUST
BLOCKING
VALVE MARKER POST

1. Coat the pipe threads with asphalt after assembly.


2. All piping shall be galvanized steel.
3. Valve and piping to valve shall be 2" unless otherwise
noted in the Contract.

THRUST BLOCKING
SHALL CLEAR PIPING

4.

Locate blowoff outlet near property corner if possible.

STREET ELBOW
TWO CONCRETE BLOCKS
4" >t 8" >t 16" (TOP BLOCK
NOT SHOWN)

METER BOX
(LOCATE IN FIELD)

BLOWOFF OUTLET

BLOCKING SHALL BE CLEAR


OF BLOWOFF PIPING
TAPPED CAP OR PLUG

PLAN

2" FEMALE >t IP >t 2 1/2" MALE NST


HOSE CONNECTION WITH CAP
(BLOWOFF OUTLET)

METER BOX
(LOCATE IN FIELD)

WATER MAIN

VARIES

VALVE BOX AND LID


-CAST IRON

DRILL 1/8" HOLE


GATE VALVE WITH 2"
SQUARE OPERATING NUT

CONCRETE BLOCK
4" )( 8" )( 16"

2 INCH BLOWOFF
ASSEMBLY
STANDARD PLAN B-90.20-00
SOLID CONCRETE BEARING
BLOCK- 4" >t 8" >t 16"

SHEET 1 OF 1 SHEET

ELEVATION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

06-08-06
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

fJ'I Washington State

NOTES

GALVANIZED OUTLET PIPE SHALL


BE SAME SIZE AS INLET PIPE WITH
BEEHIVE STRAINER AND OUTLET

1. The size of the combination air release I air vacuum


valve shall be specified in the Contract. The piping
and valves shall be the same size as the combination
air release I air vacuum valve.
2. Locate at the high point of the main, tap top of main.

CAST IRON VALVE BOX

METER BOX AND COVER

UNION

MATCH EXISTING GRADE

-SLOPE

z
<(

:::!!:
0::

L.U

1-

LL.

J:
IC..
L.U

Cl

:::!!:

::J

TYPE K
COPPER PIPE

:::!!:

:iE
Cl
L.U

u:::
C3

AIR RELEASE I AIR VACUUM VALVE

L.U

c..

(f)

BRASS PIPE AND FITTINGS


CORPORATION STOP

BRONZE GATE VALVE WITH 2"


SQUARE OPERATING NUT
GRAVEL BACKFILL FOR DRAINS

PIPE SADDLE

WATER MAIN

COMBINATION
AIR RELEASE I AIR VACUUM
VALVE ASSEMBLY
STANDARD PLAN B-90.30-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

NOTES
1. Contractor to provide blocking adequate to withstand full test pressure.
2.

Divide thrust by safe bearing load to determine required area (in square
feet) of concrete to distribute load.

3. Areas to be adjusted for other pressure conditions.


4.

Provide two 1" minimum diameter rods on valves up through 10" diameter.
Valves larger than 10" require special tie rod design.
THRUST AT FITTINGS IN POUNDS
TEST
SIZE

PLAN VIEW

PLAN VIEW

PLAN VIEW

UNBALANCED CROSS

PLUGGED CROSS

PLUGGED CROSS

(USE COLUMN A)

(USE COLUMN B)

(USE COLUMN A)

PRESSURE
(PSI)

TEE AND
DEAD
ENDS

goo
BEND

PROFILE VIEW

PLAN VIEW

PLUGGED TEE

VALVE

TEE

(USE COLUMN B)

(USE COLUMN A)

PLAN VIEW

45

22.5

11.25

BEND

BEND

BEND

4"

250

3,140

4,440

2,405

1,225

615

6"

250

7,070

9,995

5,410

2,760

1,385

8"

250

12,565

17,770

9,620

4,905

2,465

10"

250

19,635

27,770

15,030

7,660

3,850

12"

250

28,275

39,985

21,640

11,030

5,545

14"

250

38,485

54,425

29,455

15,015

7,545

16"

250

50,265

71,085

38,470

19,615

9,855

SAFE BEARING LOAD

SOIL TYPE

TWO 1" DIAM. RODS


(SEE NOTE 4)

(PSF)

MUCK, PEAT, ETC.

SOFT CLAY

1,000

SAND

2,000

SAND AND GRAVEL

3,000

SAND AND GRAVEL CEMENTED WITH CLAY

4,000

HARD SHALE

10,000

CONCRETE THRUST BLOCK


STANDARD PLAN B-90.40-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

PLAN VIEW

DEAD END

OFFSET
(USE COLUMNS B- E)

BEND

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

fJ'I Washington

06-08-06
DATE

State Department of Transportation

NOTE
Steel tie rods to be heavily coated with asphalt after installation.

lWO TIE RODS _ _____


WITH TURNBUCKLES
THREAD 6" - - - -

DIMENSION TABLE
PIPE
DIAM.

BLOCKING FOR 11.25 OR 22.5 VERTICAL BENDS

FOUR TIE RODS


WITH TURNBUCKLES - - - - -

TEST
PRESSURE
(PSI}

4"

250

6"

250

8"

250

10"

250

12"

250

14"

250

16"

250

BEND CONCRETE CUBE


VOLUME
SIZE
ANGLE
(Ft3)
(Ft}

11.25
22.5
45
11.25
22.5
45
11.25
22.5
45
11.25
22.5
45
11.25
22.5
45
11.25
22.5
45
11.25
22.5
45

6
12
22
14
27
50
25
48
89
38
75
139
55
108
200
75
147
272
98
192
355

1.8
2.3
2.8
2.4
3.0
3.7
2.9
3.6
4.5
3.4
4.2
5.2
3.8
4.8
5.8
4.2
5.3
6.5
4.6
5.8
7.1

TIE ROD
DIAM.

TIE ROD
EMBEDMENT

5/8"

17"

5/8"

17"

5/8"

17"

5/8"

17"

5/8"

17"

7/8"
5/8"
3/4"
1"
5/8"
7/8"
1 1/8"

24"
17"
20"
27"
17"
24"
30"

CONCRETE THRUST BLOCK


FOR CONVEX
VERTICAL BENDS
STANDARD PLAN B-90.50-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

BLOCKING FOR 45 VERTICAL BENDS

Harold J. Peterfeso
---~==------------

.....

STATE DESIGN ENGINEER

fJ'I Washington

06-08-06
DATE

State Department of Transportation

en
z

w
a:
w

[I]

MEDIAN BARRIER (SINGLE SLOPE


CONCRETE BARRIER SHOWN)
- SEE SECTION BELOW FOR USE
WITH CONCRETE BARRIER TYPE 2

'9

.'

MEDIAN BARRIER ~ . . .

iii

.. ,.

. '9 .

FINISHED GRADE

."'."

0:

....1
....1

I>

~ ~.II> .

.. .. ". :.. ...

"

.... _ '9
"

."

" . ~ .~>

Cl

~------1<'~~~
UNIT "H" (TYP.)

PRECAST CEMENT CONCRETE


ADJUSTMENT SECTIONS (TYP.)
-AS REQUIRED

----.

"

------------ 1:--:

91.--...........,,....,......---,-~......-J .

..

v. : " . "'

" . v

....

: " . '9

....

:~

.
..>:.. "'-:-........

-------------\
I
I

. v. .

": . , . : : : 9 . _. : "

SECTION

._..,_ .... "

..

~ GRATE INLET TYPE 2 (TYP.) -

II>

II> . . . .

'II'

._..,_ ...: ,.- .

,.--

() =
1 r-(

C')

'----

SEE STANDARD PLAN B-35.40

" v. :

..

...... : 9

.....

"

'I

......
~

J,

". :" ...... " : ...

-------------.

--

\1

..
..

~.,..........,..
.. ~~-:--..,....,--:---....,.....J. .:

.
9

I I

. ' - ____________ _y

v. :

." .."'
v :

:9.

". :

,,-----------

v. :

..

1 I

I
I
\

'9

lj

46 3/4"

11

. " .' ~ .

~----~

PIPE (TYPICAL)
- SEE CONTRACT
54"

~t-..,::.T
. . __________ _l.;.r :. .,.~.

- SEE STANDARD PLAN B-35.40

2%

..
'9

. ~

., .

SECTION

.... ____________ (t

_,;

--

..........
:

II>

:II>

"

Jlo

.. .. . ...

. ~. _:..

..

..

.. .

CONCRETE BARRIER
TYPE 2

MEDIAN BARRIER _ /

l
FINISHED GRADE

.: .

..

PLAN VIEW

MEDIAN BARRIER
DRAINAGE INSTALLATION
STANDARD PLAN B-95.20-01

HMA OR CONCRETE
(SEE CONTRACT FOR
SURFACE DETAILS)

CONCRETE BARRIER TYPE 2


SECTION
SEE SECTION

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

-----------------fll
.....

STATE DESIGN ENGINEER

02-03-09
DATE

Washington State Department of Transportation

NOTES

1. The beam guardrail type, post type, beam guardrail transition section type, connection type, and bridge traffic barrier shape may vary from that shown on this plan.

;::: 3' - 1 1/2"

_...,

'

BEAM GUARDRAIL POST (TYP.)

2. The Catch Basin or Grate Inlet shall be centered between the Beam Guardrail Posts.

CURB

3. With Beam Guardrail Transition Section Types 2, 4, and 5, use Extruded Curb
Types 1, 2, 4, 4a, 5, or Sa.
4. With Beam Guardrail Transition Section Types 1, 1A, 1B, 10, 11, and 12, use
Extruded Curb Type 2 (Extruded Asphalt Concrete Curb).

MINIMUM CURB LENGTH


-SEE NOTE 5

5. See Contract Plans for length of Curb.

PAVEMENT~

10' MIN.

BRIDGE APPROACH SLAB

BRIDGE TRAFFIC BARRIER

BEAM GUARDRAIL BLOCKS AND RAIL ELEMENTS NOT SHOWN FOR CLARITY

PLAN

BEAM GUARDRAIL
POST

FACE OF CURB SHALL


NOT EXCEED THE FACE
OF GUARDRAIL

PAVEMENT

BRIDGE APPROACH SLAB

CATCH BASIN TYPE 1 OR


GRATE INLET TYPE 2

L __
~

_j

L...------,---~--'

SECTION

PAVEMENT

INLET PLACEMENT
AT BRIDGE END
STANDARD PLAN B-95.40-00

SHEET 1 OF 1 SHEET

ISOMETRIC VIEW
MINIMUM CURB LENGTH
-SEE NOTE 5

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

06-08-06
DATE

fJ'I Washington State Department of Transportation

NOTES
1. When required by the Contract, a Snow Load Post Washer
shall be used on the backside of the post (in lieu of the 1 3/4"
Post Bolt Washer) and a Snow Load Rail Washer shall be
placed on the face side of Beam Guardrail Types 1 and 2 .
Snow Load Rail Washers shall not be installed on terminals.

....1
....1

c
c

::::i

z
c::
w

L1..

L __ J

TYPE 1

PRE-DRILLED HOLES
FOR FUTURE GUARDRAIL RAISING

2.

Rail Washers, also called "Snow Load Rail Washers" are not
required on new installation except as called for in Note 1.
Unnecessary Rail washers need not be removed from existing installations, except those on posts 2 through 8 of a BCT
installation shall be removed.

3.

Beam Guardrail post spacing for Types 1 through 4 shall be


6' - 3" on centers.

I
I

HMA OVERLAY

L __ J

L __ J

INITIAL INSTALLATION

RAIL ELEMENT RAISED

4. Timber blocks shall be toe-nailed to the post with a16d galvanized nail to prevent block rotation.

TYPE 1 ALTERNATIVE

5.

6. When "Beam Guardrail Type - _


Ft. Long Post" is specified
in the Contract, the post length shall be stamped with numbers,
1 1/2" min. high and 3/4" wide at the location where the letter
"H" is shown in the ASSEMBLY DETAIL. For wood post applications, the letter shall be stamped to a minimum depth of
1/4". For steel post applications, the letter shall be legible
after the post is galvanized. After post installation, it shall be
the Contractor's responsibility to ensure that the stamped
numbers remain visible.

518" CARRIAGE BOLT


WI HEX NUT & POST
BOLT WASHER
IN 314" HOLE

7.

C6 x 8.2 x 12'- 5 314"


MIN. LENGTH

C6 x 8.2 x 12' - 5 314"


MIN. LENGTH

L __ j

L __ j

TYPE2

518" CARRIAGE BOLT


WI HEX NUT & POST
BOLT WASHER
IN 314" HOLE

1-

""'-"
NN
N

EXISTING GUARDRAIL POST

I
I

HMAOVERLAY

I
I

L __ j

TYPE4

SEE NOTE 6

RAISED GUARDRAIL BLOCK

1 314" POST BOLT WASHER


-FOR TYPES 1 & 2 ONLY

SEE NOTE 4

TIMBER BLOCK
FOR STEEL POST

TYPES 1 &2
518" x 18" BUTTON HEAD
BOLT WI 7132" OVAL GRIP
& RECESSED HEX NUT

SEE NOTE 6

W6 x 9 OR
W6 )( 15

TYPES 3 &4
518" x 25" BUTTON HEAD
BOLT WI 7132" OVAL GRIP
& RECESSED HEX NUT
OR
518" ROD THREADED BOTH
ENDS WI HEX NUTS

518" x 1 114" BUTTON HEAD


SPLICE BOLT WI 7132" OVAL
GRIP & RECESSED HEX NUT
(EIGHT REQUIRED PER SPLICE)

TYPES 1 &2
518" x 10" BUTTON HEAD
BOLT WI 7132" OVAL GRIP &
HEX NUT WI CUT WASHER

BEAM GUARDRAIL
TYPES 1-4
(W-BEAM)
STANDARD PLAN C-1
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

TIMBER POST

STEEL POST
ALL MOUNTING AND SPLICE
HARDWARE SAME AS FOR TIMBER
POST EXCEPT AS NOTED

L __ J

BEAM GUARDRAIL RAISING FOR HMA OVERLAYS

Existing posts shall not be raised. Replace posts as


necessary to achieve required guardrail height.

TYPE3

FIELD DRILL NEW 314" HOLE


FOR 518" BUTTON HEAD BOLT

For post and block details, see Standard Plan C-1 b.

ASSEMBLY DETAIL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

7 7/8"
1"

3/4" SPLICE HOLES IN CHANNEL


RAIL AND SPLICE PLATE, FOR
5/8" CARRIAGE BOLTS

3 3/8"

1 7/8"

C6

8.2

....1
....1

13'- 6 1/2"

c
c

::::i

6'- 3"

z
c::
w

6'- 3"

~
.....

I
I
L...------C..--c----....1- --1 I
- f----------c - - - ~ I
I
I

2"

L1..

:>:
ID

"""

~
.....
~~-----i-- L - -

SPLICE PLATE3/8" X 4 1/2" X 7 7/8"

--r-Cf.

c)d)

POST
CONNECTION

3/4" x 2" POST BOLT SLOT IN CHANNEL


RAIL AND SPLICE PLATE, FOR 5/8"
BUTTON HEAD BOLT W/ 7/32" OVAL
GRIP AND RECESSED NUT
POST BOLT SLOT
(TYP.) - 3/4" X 2 1/2"

SPLICE BOLT SLOTS


(TYP.) - 29/32" X 1 1/8"

3/4" x 2" SPLICE SLOT IN


CHANNEL RAIL & SPLICE
PLATE, FOR 5/8" CARRIAGE
BOLT, HEX NUT & WASHER

CHANNEL RAIL SPLICE

TYPICAL RAIL ELEMENT

4"
2"

:
11/16" HOLE

13'- 6 1/2"

6'- 3"

6'- 2 1/4"

2 3/4"

1/4" PLATE

4 1/4" ' 4 1/4"

I
'

-~-

2"

'

SNOW LOAD
POST WASHER
SEE NOTE 1

SPLICE BOLT SLOTS


(TYP.) - 29/32" X 2"

POST BOLT SLOTS


- 3/4" X 3 3/4"

POST BOLT SLOT


- 3/4" X 2 1/2"

SPLICE BOLT SLOTS


(TYP.) - 29/32" X 1 1/8"

11/16"

BEAM GUARDRAIL
TYPES 1-4
(W-BEAM)
STANDARD PLAN C-1

31/32" SLOT

8 GAGE MIN.
PLATE

EXPANSION SECTION

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

SNOW LOAD
RAIL WASHER
SEE NOTES 1 & 2

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

NOTES

en
z

13'- 6 1/2"

w
w

1. Type 10 post shall be 6x8 timber or W6x9.


Type 11 post shall be 10x10 timber or W6x15.
For additional details see Standard Plan C-1 b.

a:
....1
....1

iii

3' - 1 1/2"
SEE NOTE 3

I.

[I]

2"

3' - 1 1/2"
SEE NOTE 3

3' - 1 1/2"
SEE NOTE 3

!"~41/4"

3'- 1 1/2"
SEE NOTE 3

2"

2. Type 10 guardrail post spacing shall be 6' - 3" on center.


Type 11 shall be a maximum of 3'- 1 1/2 "on center.

41/4"P!

3. Spacing may vary depending on application. See


Standard Specification Section 9-16.3(1)
for rail element requirements.

Cl

POST BOLT SLOT {TYP.)


- 3/4" X 2 1/2"

SPLICE BOLT SLOT {TYP.)


- 29/32" X 1 1/8"

13'- 6 1/2"
7"

TYPICAL RAIL ELEMENT


2 3/4"

6'- 2 1/4"

6'- 3"

SEE NOTE 3

SEE NOTE 3

6 1/4"
2"

ltt!l_
'
4 1/4"

POST BOLT SLOT {TYP.)


- 3/4" X 2 1/2"

SPLICE BOLT SLOT {TYP.)


- 29/32" X 2 1/2"
b

5/8" x 18" BUTTON HEAD BOLT


WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT

I
I

SPLICE BOLT SLOT {TYP.)


- 29/32" X 1 1/8"

POST BOLT SLOT {TYP.)


- 3/4" X 3 3/4"

5/8" x 1 1/4" BUTTON HEAD SPLICE


BOLT WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT -TWELVE
REQUIRED PER SPLICE

EXPANSION SECTION

~
I
I
L

__

RAIL ASSEMBLY

WOOD POST ASSEMBLY


TIMBER BLOCK
FOR STEEL POST

TYPE 10

NESTED THRIE BEAM

THRIE BEAM GUARDRAIL


- NESTED FOR TYPE 11

5/8" x 25" BUTTON HEAD BOLT


WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT

I
I

SEE NOTE 1

5/8" x 10" BUTTON HEAD


BOLT W/ 7/32" OVAL GRIP &
HEX NUT W/ CUT WASHER

5/8" x 1 1/4" BUTTON HEAD SPLICE


BOLT WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT- TWELVE
REQUIRED PER SPLICE

STANDARD PLAN C-1a

~
I
I
L

__

BEAM GUARDRAIL
(THRIE BEAM)
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

RAIL ASSEMBLY

WOOD POST ASSEMBLY

TYPE11

STEEL POST ASSEMBLY

TYPE 10 AND 11

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

..J
..J

NOTES

c
c
:J
z
w

1. Wood posts for all guardrail placement plans shall be 6 x 8


except where noted otherwise.

2. Lower hole is for Rub Rail of Type 2 and Type 3 Beam Guardrail.

3. W6x9 steel posts and timber blocks are alternates for 6 x 8


timber posts and blocks. W6x 15 steel posts and timber
blocks are alternates for 10 x 10 timber posts and blocks.

II::

1&.

~
WOOD BREAKAWAY POST

4. Holes shall be located on approaching traffic side of web.


5. When "Beam Guardrail Type - __ Ft. Long Post" is specified
in the Contract, the post length shall be stamped with numbers,
1 1/2" min. high and 3/4" wide at the location where the letter
"H" is shown in the ASSEMBLY DETAIL. For wood post applications, the letter shall be stamped to a minimum depth of
1/4". For steel post applications, the letter shall be legible
after the post is galvanized. After post installation, it shall be
the Contractor's responsibility to ensure that the stamped
numbers remain visible.

5/8" X 10" BOLT,


NUT AND WASHER

5/8" X 10" BOLTS,


NUTS AND WASHERS
(TWO REQUIRED PER POST)
WELDED OPTION FOR
STEEL TUBE AND
1/4 SOIL PLATE CONNECTION
(SEE NOTE 6)

6. Soil plate may be welded to foundation tube. If so,


holes in soil plate and foundation tube may be omitted.

SOIL PLATE
FOUNDATION TUBE

BOTTOM CORNERS
MAY BE CLIPPED
2" x 2" TO AID DRIVING

FRONT VIEW

SIDE VIEW

ANCHOR POST ASSEMBLY

G-2 POST

SEE NOTE 5

SEE NOTE 5

BEAM GUARDRAIL
POSTS AND BLOCKS
STANDARD PLAN C-1b
SHEETS 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

TIMBER POST

STEEL POST

PARTIAL ASSEMBLY DETAIL

ANCHOR POST

G-2 POST

ISOMETRIC

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

8" OR 10"

8" OR 10"

I"" (NOM.) I

I"" (NOM.) I

,.
. I

1 1/8" FOR wsxg

3/4" DIAM.
HOLE (TYP.)

ALTERNATE HOLE

3/4" DIAM.
HOLE (TYP.)
3/4" DIAM.
HOLE (TYP.)
w

...J

...J

Ill

8 OR 10

10

J:

Ill

J:

SEE NOTE 2 ~

(!)

(!)

(!)

8 OR 10

10

J:

1-

...J

Ill

1-

(!)

...J

Ill

1-

...J

...J

...J

...J

!i;

!i;

!i;

!i;

ll.

ll.

w
w

w
w

w
w

(/)

ll.

(/)

ll.

w
w

(/)

(/)

3/4" DIAM.
HOLE

__[______LJ

1/4" STEEL
PLATE

W-BEAM

THRIE BEAM

W-BEAM

THRIE BEAM

WOOD POST

3/4" DIAM.
HOLE

'

SOIL PLATE

STEEL POST
SEE NOTES 3 AND 4

..J
..J

c
c

:J

TS 8" X 6"
(STEEL)

POST LENGTH TABLE

~
w

1&.

~
c

GUARDRAIL
TYPE

LENGTH

1 through 4 & 31

6'- 0"

10 or 11

6'- 6"

0.1875"

FOUNDATION TUBE
8" (NOM.>.
1

3/4" DIAM.
HOLE

K.

POST

~ K.

"

W6
W6

6"*

4 1/4"

15

8"*

6 1/4"
2 3/8" DIAM. HOLE

NOMINAL (NOM.)

BEAM GUARDRAIL
POSTS AND BLOCKS
3/4" DIAM. THRU
HOLE (TYP.)

3/4" DIAM. THRU


HOLE (TYP.)

3/4" DIAM. THRU


HOLE

STANDARD PLAN C-1b


SHEETS 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

THRIE BEAM WOOD BLOCK


FOR WOOD POST

W-BEAM WOOD BLOCK


FOR WOOD POSTS

THRIE BEAM WOOD BLOCK


FOR STEEL POST

W-BEAM WOOD BLOCK


FOR STEEL POST

CONTROLLED RELEASING
TERMINAL (CRT) POST

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

NOTES
1,

For post de to i Is see Stondord PI on,


"Beom Guordro i I Posts ond B I ock s",

_j_
See Deto i I

See Deto i I

C'l

G-2

7; 5 "

DIA x 1 1/ 2 " hex heod


bolt w i th hex nut ond
174 " squore x , 135" wosher

Post----~

DETAIL A

(See Note 1)

TYPE 20

1/2"

DIA x 1 1/2" Hex


heod bolt with hex nut,
Guordro i I rests on top
of boIL

DETAIL B

TYPE 21

BEAM GUARDRAIL

STANDARD PLAN C-lc


APPROVED FOR PUBLICATION
Donald K. Nelson

5130197

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

NOTES
1.
For wood posts, saw top of post and block to 1" above thrie beam guardrai I
reducer section. For steel posts, drive post down to 1" maximum above the
thrie beam guardrai I reducer section.

See Note 1

D
INTERMEDIATE GUARDRAIL
POST CONNECTION DETAILS
!Type A shown)

Ya G /,

~~-__,_..._--+--[7+---~ Ty p l

Cap pI ate\
CD

CD

6'- 3"

CD

6'- 3"

0
N

=
CD

CD

CD
CD

CD

Splice bolt slots


2o/32 " x 1Y8 " ITYPl

7 I

2"

--'=----

4Yi'~~'li'
14

CD
CD
'

CD

PJ

'

3'- 1 Y2"

~1

'

3/':2

'

'

CD

'

CD

Sp I ice bo It slots
2%2 " X 1 Ya" ITYPl

3'- 1 Y2"

THRIE BEAM GUARDRAIL REDUCER SECTION


TYPE A

1
2"
4J'4
I :14c /4"
~1
---=-------c

CD
CD
'

CD

~
I

CD
'

CD

~Post
bolt slots
ITYPl
7'4"
X

'------- 10 Gage

!Left section shown. right section reversed)

CD
CD

Post bolt slots


X 2Y2" ( TYP)

%"

2Y2"

'
'

=
'
'

CD

CD
CD
'

CD

THRIE BEAM GUARDRAIL


REDUCER SECTION

'

CD
CD

CD

STANDARD PLAN C-1d

SHEET 1 OF 1 SHEET

10 Gage

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

THRIE BEAM GUARDRAIL REDUCER SECTION


TYPE B

0912003

ADDED 10 GAGE STEEL DESIGNATION! REV. NOTE I

RG

DATE

REVISION

BY

STATE DESIGN ENGINEER

10-31-03
DATE

fJ'I Washington State Department of Transportation

ANCHOR
PAY
LIMIT

NOTES
BEAM GUARDRAIL
PAY LIMIT

(SEE
NOTE 1)

TERMINAL PAY LIMIT SRT SHOWN


(SEE NOTE 3)

1. Type 4 anchor required. For details, see Standard


Plan C-6c.
2. Post spacing is 6'-3" unless otherwise shown.
3. For Terminal type and details, see Contract Plans and
applicable Standard Plan(s).

[VARIES (SEE CONTRACT)

__,

4. The slope from the edge of the shoulder into the


face of the guardrail should not exceed 10:1 when
the face of the guardrail is less than 12'-0" from
the edge of the shoulder.

'=EDGE OF SHOULDER

ONE WAY TRAFFIC

5. For one-way traffic, use Type 4 anchor. For two-way


traffic, use Type 1 anchor. See applicable Standard
Plan(s) for details.

CASE1

BEAM GUARDRAIL
PAY LIMIT
(SEE NOTE 6)

TERMINAL SRT SHOWN SEE NOTE 3

6. When Beam Guardrail Flared Terminals are used on both


ends a minimum of 25'-0" of Beam Guardrail shall be
installed.
TERMINAL SRT SHOWN SEE NOTE 3

[VARIES (SEE CONTRACT)

'=EDGE OF SHOULDER
_, TWO WAY TRAFFIC

CASE2

'

ANCHOR
PAY

BEAM
LIMIT GUARDRAIL
(SEE
NOTE 5) PAY LIMIT

I
I

12'-0" MIN

6'-0" MIN.

~~;

I (.

:_J -~~

'

'
1

TERMINAL (SRT SHOWN) SEE NOTE 3

CENTER OF RAILROAD
SIGNAL SUPPORT

M H

R 1'1

n "

_:)
1'\

1'1

--

L--

SEE NOTE 4

GUARDRAIL PLACEMENT

'=EDG E OF SHOULDER

[VARIES (SEE CONTRACT)


__,e

f:1

ONE OR TWO WAY TRAFFIC

CASE3

STANDARD PLAN C-2


APPROVED FOR PUBLICATION

RAILROAD

....

Clifford E. Mansfield

ct
I
I

STATE DESIGN ENGINEER

01-06-00
DATE

12/99

IADDED
NOTE 6. MODIFIED THE END SECTIONS TO llWS
fJ'I Washington State Department of Transportation
DESIGN "C".

DATE

REVISION

I BY

BEAM GUARDRAIL TRANSITION SECTION


PAY LIMIT- SEE NOTE 3

TERMINAL PAY LIMIT (SRT SHOWN)

BEAM GUARDRAIL PAY LIMIT


X SPACES @ 6' - 3"

SEE NOTE 1

SEE FLARE RATE TABLE


ONE OR TWO-WAY TRAFFIC

BRIDGE

EDGE OF SHOULDER

NOTES

CASE4

1. For terminal type and details, see Contract and applicable


Standard Plan(s).
2. The slope from the edge of the shoulder into the face of the
guardrail should not be steeper than 10H:1V when the
guardrail is within 12' - 0" from the edge of the shoulder.

BEAM GUARDRAIL TRANSITION SECTION


PAY LIMIT- SEE NOTE 3

TERMINAL PAY LIMIT (SRT SHOWN)

BEAM GUARDRAIL PAY LIMIT


X SPACES @ 6' - 3"

SEE NOTE 1

3. See Contract for Beam Guardrail Transition Section type and


Connection to Bridge Traffic Barrier or Concrete Barrier.

t~~~~~~~=-=-~-~~~~-41lj~~j~~J~~J~~J~~J~~==~~~~t~~====~==~==~==~--~-~-!--~-~-~--~-~-~--~-~-:~~-~-~--~-~-~--~-~-~-J_i~~:~~~~=~BRIDGE

BRIDGE TRAFFIC BARRIER

ONE OR TWO-WAY TRAFFIC

FLARE RATE TABLE


POSTED SPEED
(MPH)

RATE

70

15 : 1

60

14 : 1

55

12 : 1

50

11 : 1

45

10 : 1

40 OR LESS

9: 1

CURB FACE EXTENSION LINE

CASES

BRIDGE

..- ONE-WAY TRAFFIC

BRIDGE TRAFFIC BARRIER

BEAM GUARDRAIL TRANSITION SECTION


PAY LIMIT- SEE NOTE 3

MEDIAN

BEAM GUARDRAIL PAY LIMIT


X SPACES @ 6' - 3"
70 MPH ..................... 200' - 0"
60 MPH ..................... 137'- 6"
55 MPH OR LESS .... 100'- 0"

TERMINAL PAY LIMIT (SRT SHOWN)


SEE NOTE 1

GUARDRAIL PLACEMENT
STANDARD PLAN C-2a

BRIDGE END

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

BRIDGE

ONE-WAY TRAFFIC_..

....

Harold J. Peterfeso

05/2006

CASES

DATE

APPLIED CURRENT DRAFTING STANDARDS


REVISION

MAS

BY

STATE DESIGN ENGINEER

06-21-06
DATE

fJ'I Washington State Department of Transportation

BEAM GUARDRAIL
TYPE 3 OR4
PAY LIMIT
(SEE NOTE 1)

BEAM GUARDRAIL
TYPE 1 OR 2
PAY LIMIT (SEE NOTE 1)

BEAM GUARDRAIL TYPE 10


PAY LIMIT
12'- 6" MIN.

BEAM GUARDRAIL TRANSITION SECTION


TYPE 16- PAY LIMIT

BEAM GUARDRAIL TYPE 11


PAY LIMIT (SEE NOTE 2)

BEAM GUARDRAIL
TYPE 1 OR 2
PAY LIMIT (SEE NOTE 1)

SPACED @ 3' - 1 1/2" MAX. (TYP.)

POSTED SPEED
(MPH)

RATE

70

15: 1

SEE FLARE RATE TABLE

60

14: 1

55

12: 1

..-c

't \

12'- 6" MIN.


BEAM GUARDRAIL TYPE 11
PAY LIMIT (SEE NOTE 2)

BEAM GUARDRAIL TYPE 10


PAY LIMIT

PLAN VIEW
z

TIMBER
POST

en
z

::::>
0:::

STEEL
POST

ATTACH RAIL & BLOCK TO POST


WITH TWO 5/8" x 14" LAG BOLTS

THRIE BEAM GUARDRAIL

~ REDUCER SECTION TYPE B

CASE7

2.

NORMAL RAIL-BLOCK-POST
ATTACHMENT

Ill

<
z
w
w

TOP OF ROADWAY

...J

SECTION

BEAM GUARDRAIL
TYPE 3 OR4
PAY LIMIT
(SEE NOTE 1)

BEAM GUARDRAIL
TYPE 1 OR 2
PAY LIMIT (SEE NOTE 1)

ATTACH STANDARD BLOCK TO RAIL


WITH TWO 5/8" x 4" LAG BOLTS (TYP.)

4.
DETAIL

BEAM GUARDRAIL TYPE 10


PAY LIMIT
12'- 6" MIN.

11 : 1
10: 1

40 OR LESS

9: 1

Use the minimum number of nested 12'- 6" thrie beam sections needed to
span the structure. This run may extend past the end of the structure, and
an excess of 6' - 3" maximum is acceptable. If the last 12' - 6" section extends more than 6' - 3" (but less than 12' - 6"), use a nested 6' - 3" thrie
beam section in its place.

3. The Beam Guardrail Transition Section Type 16 on this end shall terminate
at a 1Ox 10 post. Place nested thrie beam with 1Ox 10 posts at 3' - 1 1/2"
maximum spacing between the end of the transition and the structure.

TOP OF FOUNDATION

Cl

50
45

1. Varying flare rates and structure widths may require a length of Beam
Guardrail Type 1 or 2 between the Beam Guardrail Type 3 or 4 and the
Transition on one side, and the Beam Guardrail Type 10 on the other. For
Beam Guardrail Type 2 or 3, terminate the rub rail (channel rail) at the first
6x8 post of the Beam Guardrail Transition Section Type 16, and by lapping
it behind the second 6x8 post on the Beam Guardrail Type 10 side, or as
approved by the Engineer.

(WOOD POST AND BLOCK SHOWN)


jjj
l-

ONE-WAY TRAFFIC

NOTES

SEE FLARE RATE TABLE


ONE-WAY TRAFFIC __.
BEAM GUARDRAIL TRANSITION SECTION
TYPE 16- PAY LIMIT (SEE NOTE 3)

FLARE RATE TABLE

PAY LIMIT
(SEE NOTE 1)

EQUALLY SPACED
@ 6'- 3" MAX.

STRUCTURE (TYP.)

MEDIAN

BEAM GUARDRAIL
TYPE 3 OR4

BEAM GUARDRAIL TYPE 11


PAY LIMIT (SEE NOTE 2)

BEAM GUARDRAIL TRANSITION SECTION


TYPE 16- PAY LIMIT

SPACED @ 6' - 3" MAX. (TYP.)

If full post depth cannot be achieved due to the structure foundation, post
length shall be adjusted to the top of foundation. The Beam Guardrail
Type 11 post height shall be 2' - 9".

BEAM GUARDRAIL
TYPE 1 OR 2
PAY LIMIT (SEE NOTE 1)

BEAM GUARDRAIL
TYPE 3 OR4
PAY LIMIT
(SEE NOTE 1)

EQUALLY SPACED

@ 6'- 3" MAX.


STRUCTURE

cC

ONE-WAY TRAFFIC

SEE FLARE RATE TABLE


MEDIAN

't \

fr- ~ ~~ 1-~s: :-m --:-~-:---~


GUARDRAIL PLACEMENT

RUB RAIL (CHANNEL


RAIL) - SEE NOTE 1

SEE FLARE RATE TABLE


ONE-WAY TRAFFIC ~

12'- 6" MIN.


BEAM GUARDRAIL TRANSITION SECTION
TYPE 16- PAY LIMIT (SEE NOTE 3)

BEAM GUARDRAIL TYPE 11


PAY LIMIT (SEE NOTE 2)

STANDARD PLAN C-2b

BEAM GUARDRAIL TYPE 10

SHEET 1 OF 1 SHEET

PAY LIMIT

APPROVED FOR PUBLICATION

CASES

....

Harold J. Peterfeso

PLAN VIEW
(WOOD POST AND BLOCK SHOWN)

05/2006
DATE

OMITTED ATTACHMENT TO STRUCTURE INDTE


REVISION

1>

EAB

BY

STATE DESIGN ENGINEER

fJ'I Washington

06-21-06
DATE

State Department of Transportation

NOTE
BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 1)

BEAM GUARDRAIL TYPE 10

BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 1)

PAY LIMIT

PAY LIMIT

PAY LIMIT

1. CASE 9C: Thrie Beam Guardrail is used when the distance from the end of the Bullnose
Terminal to the beginning of the transition of the Bridge Rail is less than 100 feet.

.-: DIRECTION OF TRAFFIC

EDGE OF TRAVELED WAY

CLEAR AREA - SEE


STD. PLAN C-4f \

'

3' - 0" iiN. - TO FACE OF GUARDRAIL

L.

1 A47 ~
--

<~

~ ~II/

.Y"

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B \

/8. ~ ~l<<i

L.

)---

BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 2)


PAY LIMIT

BEAM GUARDRAIL (W-BEAM)


PAY LIMIT

;j
EDGE OF TRAVELED WAY

DIRECTION OF TRAFFIC __.

~ 3' - 0" ~IN. - TO FACE OF GUARDRAIL

\ _ CLEAR AREA - SEE


STD. PLAN C-4f
15

DIRECTION OF TRAFFIC

BEAM GUARDRAIL TYPE 10

~-------+----------1cc===~~~==~---------t---t-----------------

EDGE OF TRAVELED WAY

PAY LIMIT

CASE9A

CJ)

w
w

0:::

CLEAR AREA - SEE


STD. PLAN C-4f

IIl
....1
....1

iii

EDGE OF TRAVELED WAY

BEAM GUARDRAIL (W BEAM OR THRIE BEAM

BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 2)


PAY LIMIT

--E

EDGE OF TRAVELED WAY

15

- SEE NOTE 1)

PAY LIMIT

0
-----=----

t1

t1

t1

t1

t1

t1

t1

t1

v
\_

END SECTION - DESIGN F

BRIDGE TRAFFIC BARRIER

f--------------------------------

.H..

15

DIRECTION OF TRAFFIC

-:-:-:

PAY LIMIT

CASE9B

._jf .
CLEAR AREA -SEE
STD. PLAN C-4f

BEAM GUARDRAIL CW-BEA.M

...._ DIRECTION OF TRAFFIC

ti

THRIE BEAM GUARDRAIL ~


REDUCER SECTION TYPE B

THRIE BEAM GUARDRAIL REDUCER SECTION


TYPE B - REQUIRED WHEN TERMINAL JOINS
W-BEAM (SEE NOTE 1)

0
-----=----

RRR\ilili

BRIDGE TRAFFIC BARRIER

GUARDRAIL PLACEMENT
MEDIAN BULL NOSE
STANDARD PLAN C-2c

EDGE OF TRAVELED WAY

BEAM GUARDRAIL (W-BEAM OR THRIE BEAM - SEE NOTE 1)

BEAM GUARDRAIL
TRANSITION SECTION
TYPE 1

PAY LIMIT

PAY LIMIT

CASE 9C

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

05/2006

CLARIFIED DIMENSION OF CLEARANCE TO HAZARD


IN CASE 9A

WJB

DATE

REVISION

BY

STATE DESIGN ENGINEER

06-21-06
DATE

fJ'I Washington State Department of Transportation

BEAM GUARDRAIL PAY LIMIT

TERMINAL PAY LIMIT- SEE NOTE 1

NOTES

1. SRT Terminal shown, for terminal type and details, see


Contract or applicable Standard Plan(s).

2. Post spacing is 6'- 3" except where noted.


3. Type 4 anchor required. See applicable Standard Plan(s).
4. The slope from the edge of the shoulder into the face of
the guardrail should not exceed 10H:1V when the guardrail
is within 12' - 0" from the edge of the shoulder.

VARIES - SEE CONTRACT

EDGE OF SHOULDER
TWO-WAY TRAFFIC

CASE10A

ANCHOR PAY LIMIT


-SEE NOTE 3
BEAM GUARDRAIL PAY LIMIT

BEAM GUARDRAIL PAY LIMIT

11'-0" MIN.

~___[
fj

EDGE OF SHOULDER

TERMINAL PAY LIMIT- SEE NOTE 1

~_[3'-0"Ml

3'-0"MIN.

fj~

EDGE OF SHOULDER

..-c ONE-WAY TRAFFIC

7
.,.. ONE-WAY TRAFFIC

CASE10B

OR
TWO-WAY TRAFFIC

CASE 10 A, B, or C

ANCHOR PAY LIMIT


-SEE NOTE 3 . \
BEAM GUARDRAIL PAY LIMIT

~--~--~------------------------------------------------~

BEAM GUARDRAIL EXTENSION


LENGTH VARIES - SEE CONTRACT

GUARDRAIL PLACEMENT
STANDARD PLAN C-2d
SHEET 1 OF 1 SHEET
EDGE OF SHOULDER

APPROVED FOR PUBLICATION

CASE10C

....

Harold J. Peterfeso

.,.. ONE-WAY TRAFFIC


05/2006

CLARIFIED DIMENSION OF CLEARANCE FOR HAZARD

MAS

DATE

REVISION

BY

STATE DESIGN ENGINEER

06-21-06
DATE

fJ'I Washington State Department of Transportation

BEAM GUARDRAIL TRANSITION


SECTION TYPE 17 OR 18

BEAM GUARDRAIL FLARED TERMINAL- PAY LIMIT (SEE NOTE 1)

BEAM GUARDRAIL TYPE 11


PAY LIMIT (SEE NOTE 4)

PAY LIMIT

BEAM GUARDRAIL FLARED TERMINAL- PAY LIMIT (SEE NOTE 1)

BEAM GUARDRAIL TRANSITION


SECTION TYPE 16- PAY LIMIT

BEAM GUARDRAIL TYPE 1 - PAY LIMIT


X SPACES @ 6' - 3", 0 SPACES MIN.

BEAM GUARDRAIL TYPE 1 - PAY LIMIT


X SPACES @ 6' - 3", 0 SPACES MIN.

l~~SE~E~NO~TE~3==lL~=Ld~~=,liLJbtJ,l~~~~~~~/~'lfj~L~~d~hl~"={~~J~~I?~\~~~~LjlfJ~~ibk~~~~Llt~~l=L~=bdbJ=b=~*1~

:SEE NOTE 3

SEE NOTE 6

_j

\__ SEE NOTE 6

TWO-WAY TRAFFIC

'=

VARIES - SEE CONTRACT

EDGE OF SHOULDER

NOTES

CASE 11A

1. SRT Terminal shown. For terminal type and details


see Contract and applicable Standard Plan(s).

jjj
1-

2. Beam Guardrail Anchor Type 4 (W-Beam) or Type 4


(Thrie Beam) required.

C/)

::I

0::

III

~
w

3. The slope from the edge of the shoulder into the


face of the guardrail should not exceed 10H:1V
when the guardrail is within 12' - 0" from the edge
of the shoulder.

....1

BEAM GUARDRAIL
ANCHOR TYPE 4

PAY LIMIT
(SEE NOTE 2)

BEAM GUARDRAIL TYPE 11

BEAM GUARDRAIL TRANSITION

PAY LIMIT (SEE NOTE 5)

SECTION TYPE 16- PAY LIMIT

Cl

Cit

t{

~~
\

\__

fJ l~l~ fJ
SEE NOTE 6

~~~
I

BEAM GUARDRAIL FLARED TERMINAL

- PAY LIMIT (SEE NOTE

1)

4. If the distance from end of Beam Guardrail Type 11


to the structure exceeds 6' - 3" using 12' - 6" thrie
beam sections, add a 6' - 3" nested section of thrie
beam with 10x10 posts, spaced at 3'- 1 1/2" maximum, and begin transition.

BEAM GUARDRAIL TYPE 1 - PAY LIMIT


X SPACES @ 6' - 3", 0 SPACES MIN.
~

~ ~L ~

__/

ONE-WAY TRAFFIC

~SEE

ll

~ VARIES - SEE CONTRACT

NOTE3

\__ EDGE OF SHOULDER

5. Guardrail post spacing for Beam Guardrail Type 11


past the end of the structure shall be spaced at
6' - 3" maximum with 6x8 post and standard block.
6. Attach the standard wood block to the rail using two
5/8" x 4" lag bolts.

CASE11B

THRIE BEAM GUARDRAIL

'V" REDUCER SECTION TYPE B


BEAM GUARDRAIL
ANCHOR TYPE 4

BEAM GUARDRAIL
TYPE 1

PAY LIMIT
(SEE NOTE 2)

PAY LIMIT

BEAM GUARDRAIL TYPE 11


PAY LIMIT (SEE NOTE 5)

BEAM GUARDRAIL TRANSITION


SECTION TYPE 16- PAY LIMIT

BEAM GUARDRAIL FLARED TERMINAL

- PAY LIMIT (SEE NOTE

BEAM GUARDRAIL TYPE 1 - PAY LIMIT


X SPACES @ 6' - 3", 0 SPACES MIN.

SEE NOTE 6

VARIES - SEE CONTRACT


,

1)

~)

GUARDRAIL PLACEMENT

~SEE

STANDARD PLAN C-2e

NOTE 3

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

EDGE OF SHOULDER

ONE-WAY TRAFFIC
05/2006

CASE11C

....

Harold J. Peterfeso

DATE

OMITTED ATTACHMENT TD STRUCTURE INDTE 2>


REVISION

EAB

BY

STATE DESIGN ENGINEER

06-21-06
DATE

fJ'I Washington State Department of Transportation

Point B
(CRT post
with block)

NOTES
See Note 2

Beom Guordro i I
Anchor Type 7

X Spoces
ot 5'- 3"
(1 spoce MIN)

Term i no I p o y I i mi t

Be om
Guordro i I
Anchor

')
L o

The slope from the edge of the shoulder i nto the foce of
the guordroi I should not be steeper thon 10:10

( S RT shown ) see No t e 4

Attoch to ro i I wi th 1j6 " x 9" long bolt, nut ond


1 1/ 2 " wosher on bock of post,
For term i no I type ond de to i Is , see Contract ond
opp I i cob I e Stondord PI on ( s),

(see Note 7)

>I

4IIIC

\X Spoces ot 5'- 3" (1 spoce MIN)


I
Type 5 Trans i t i on poy I i mi t

._~---1.'---~----'---~v

Type 7

See Controct for guordro i I connect i on to br i dge ro i I ond


concrete borr i er"

CASE 12 _D

Beom Guordro i I
poy I imit

Ro i I
not bolted
to CRT post

1"

/See Note

>ic

Rod ius dimensions sho I I be etched into pI ote rep I oc i ng


the I etters "HH", shown on the I dent i f i cot i on PI ote Deto i I,
Di g i ts sholl be 1 1/2" MI N height ond %"MAX wi dth"
The pI ote sho I I be go I von i zed ofter etch i ng,

5,

Point B
(CRT post
wi th block)

fQ_

s'-

5"

Ln

CASE 12 _c
(see Note

7,

F i rst letter of cose des i gnation placement i nd i cates end


treatment on side rood,
Second letter i nd i cates end
treatment on mo i n rood,
For i nstance, o Type 5 Anchor
on the side rood ond o bridge connection on the moin rood
would be Cose 12 AC,

So

For the 8'- 5" rod i us, five CRT posts ore requ i red
includ i ng the CRT post ot point B,

9,

For CRT post deto i Is, see Stondord Pion "Beom Guordro i I Posts
ond Blocks",

7)

_C

+-

+-

/-,

f--0::::

0>

u
0
L

3::

Q_:z:

0
Q_

CLEAR AREA

(f) C'l
+- QJ
(f)+-

The guordro i I rod i us I dent if i cot i on PI ote sho I I be mounted


on the bock s i de of the Ro i I E I ement us i ng the I owest
sp I i ce bo It ot the P, C, of the guordro i I rod i us

CD

QJ
QJ

(f)

Po i nt A

D
L
0

:::J
(_')

5'- 3" Post


spocing (TYP)

E
0
QJ
OJ

%"Hole with snug fitting


i nsert, %" I D, 7 1/ 2 " I ong

c::
<(

Hole

CRT Post

L
_C

11
12''

1j5"
Bolt

+-

>I

Wosher

-E
0L

D>->
L 0
OQ_
::J

SECTION A-A

CASE 12 A_

lj~ "

Steel
plote

(see Note 8)

GUARDRAIL PLACEMENT
WEAK POST
DESIGN ( 8
I

(_') Ln

Q)

OD_
Q))'-,

OJ f-

Sp I ice
bolt
slot

--+---+~~""""'l

IDENTIFICATION PLATE

Ro i I

(see Note 5)

STANDARD PLAN C-2f


Ident i f i cot i on plote

Post

IDENTIFICATION PLATE
MOUNTING DETAIL
(see Note 5)

APPROVED FOR PUBLICATION

See Note 2

CASE 12 B_

3114197

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

(see Note 7)

Donald K. Nelson

NOTES

;:2
...,

SEE NOTE 2
PT

:::>

CJ)
~

<t:

::!!:
:;,..:

NUMBER OF
CRT POSTS

III

RADIUS

(SEE NOTE 3)

1. See Contract Plans for guardrail connection to bridge


rail and concrete barrier.

REQUIREMENTS

0:::

2. The slope from the edge of the shoulder into the face
of the guardrail should not be steeper than 10:1.

BEAM GUARDRAIL
ANCHOR TYPE 7

CLEAR AREA

X SPACES
AT 6'- 3"
(1 SPACE MIN.)

17'- 0"

30'

15'

25'- 6"

40'

20'

35'- 0"

11

50'

20'

3. Fewer CRT posts are required for smaller radii; include


CRT Post at Point B. Attach guardrail to post with a
5/16" x 9" long bolt, a 3/8" I.D. x 7 1/2" snug fitting insert,
and a 1 1/2" washer with nut on back of post.

TERMINAL PAY LIMIT (SRT SHOWN)


(SEE NOTE 4)

CASE 13_D
(SEE NOTE 7)

4. For terminal type and details, see Contract and


applicable Standard Plan(s).

POINT B
(CRT POST WITH BLOCK)

BEAM GUARDRAIL
ANCHOR TYPE 7

BEAM GUARDRAIL

TYPE 5 TRANSITION

PAY LIMIT

PAY LIMIT

X SPACES AT 6'- 3"


SEE NOTE

(1 SPACE MIN.)

bil

bil

5. Radius dimensions shall be etched into plate replacing


the letters "HH", shown on the GUARDRAIL RADIUS
IDENTIFICATION PLATE DETAIL. Digits shall be
1 1/2" minimum height and 3/4" maximum width. Plate
shall be galvanized after etching.

1~

bilbilbilbil~

6. The guardrail radius Identification Plate shall be


mounted on the back side of the rail element using
the lowest splice bolt nearest the PC of the guardrail
radius (See View A).

---=f
BRIDGE END

CASE13_C

7. The first letter of the Case Designation indicates the


end treatment on the side road. The second letter
indicates the end treatment on the main road. For
example, a Type 5 Anchor on the side road with a
bridge connection on the main road would be Case
13 AC, the combination shown.

(SEE NOTE 7)

8. For CRT post details, see Standard Plan C-1b.

314" HOLE
SNUG FITTING INSERT
318" I.D., 7 112" LONG
L (SEE TABLE)

1 112" WASHER

--------:-:0/
NUT\

X SPACES
AT 6'- 3"
(1 SPACE MIN.)

GUARDRAIL RADIUS
IDENTIFICATION PLATE
(SEE DETAIL)

CRT POST

(SEE NOTES 3, 6 & 8)

POINT A

VIEW0

~
J:

CJ)

1-

g:;'i'
~UJ

1- 1-

~~

...J

LlJ
LlJ

c..~
...J

<t:
z

114" STEEL PLATE

:iE
BEAM GUARDRAIL
ANCHOR TYPE 5
PAY LIMIT

MIN.

0:::
LlJ

1-

(SEE NOTE 5)

SEE NOTE 2

CASE 13A_

CASE 13 B_

(SEE NOTE 7)

(SEE NOTE 7)

GUARDRAIL RADIUS
IDENTIFICATION PLATE
DETAIL

APPROVED FOR PUBLICATION

....

Clifford E. Mansfield

7/01

ADDEO ""VIEW A""

MAS

DATE

REV I 5 I ON

BY

CORRECTED NOTES;

STATE DESIGN ENGINEER

07-27-01
DATE

fJ'I Washington State Department of Transportation

NOTES
1, For Serv i ce Level
see Controct,

1, Weok Post Br i dge Ro i I System,

2, SRT Term i nol shown,


For Terminol type ond deto i Is,
see Contract ond opp I i cob I e Stondord PI on ( s),
3, The slope from the edge of the shoulder i nto the foce
of the guordro i I should not be steeper thon 10:1,
4, See Stondord Pion "Beom Guordroi I Posts ond Blocks",

Term i nol poy I i mi t

(see Note 2)

Type 1
Beom Guordro i
poy I i mi t
(0 spoces MIN)

Type 5 Trans i
poy I i mi t

t i on----------~

Type 20 Beom Guordro i


poy I i mi t

Type 1
Beom Guordro i
poy I i mi t
(0 spoces MIN)

Term i nol

poy I i mi t

(see Note 2)

Thr i e Beom Guordroi


Reducer Section Type B

Direction of Traffic

CASE 14

GUARDRAIL PLACEMENT

STANDARD PLAN C-2h


APPROVED FOR PUBLICATION

Donald K. Nelson

3128197

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

NOTES

Terminol

poy

limit

(see Note 1)

Beom Guordroi
poy I i mit

Term i nal

r----

Mod i fied Beom Guordro i I (see Deto i I ond Note 3)

Poy L i mi t

SRT Terminol shown,


For Term i nol type ond
deto i Is, see Contract ond opp I i cob I e Stondord
PI on ( s),

2o

The slope from the edge of the shoulder i nto


the foce of the guordro i I shou I d not be steeper
thon 10:1 ,

3,

See Stondord Pion for Box Culvert Guordro i I


Stee I PosL

4,

For spons up to 18'- 9", see Stondord Pion


for Guordro i I Placement Coses 19, 20, ond 21,

(see Note 1)

Spoces ot 5'- 3"


0 Spoces MIN

(TYPl

Box

c~
I

JL=f

f=1l

Direction of Traffic

CASE 15

GUARDRAIL PLACEMENT

..
I
I
I
I
I
I

I'
See Note

3--~

STANDARD PLAN C-2i


APPROVED FOR PUBLICATION

25'

(see Note 4)

DETAIL

Donald K. Nelson

3128197

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

NOTES

Anchor poy I i mit


(see Note 1)
Be om Guordro i I poy

Terminol

I i mit

1,

poy I i mi t (SRT shown)


(see Note 2)

Type 4 onchor requ i red,

For

de to i Is

see

opp I i cob I e Stondord PI on ( s),


2,

For term i no I type ond de to i Is,

see contract ond

oppl i coble Stondord Plon(s),


See Note 5

3,

Post spocing

is 5'-3" except where noted,

For guordro i I to br i dge ro i I connect i on see

\:__See TobIe

opp I i cob I e Stondord PI on ( s)

\L

(see contract)

Edge of shou I der

or Contract,

The slope from the edge of the shoulder

i nto the

foce of the guordro i I shou I d not be steeper thon


One Woy Troff i c

10:1 when the guordro i l

i s within 12'-o" from

the edge of the shou I der,

Beyond 12'- 0"

the

slope shol I not be steeper thon 5:1,

CASE 16

Term i no I p o y I i m i t ( SRT shown )


(see Note 2)

Beom Guordro i I poy

I i mi t

FLARE RATE TABLE


Rote
Posted Speed
(MPH)
70
15 : 1

Term i no I p o y I i m i t ( S RT shown )
(see Note 2)

(see Note 3)

50

14 : 1
12 : 1

55

11 : 1

50
45

1 0: 1
9: 1

40 or

less

See
Note 5

Vor i es

Edge of shoulder

(see contract)
Two Woy Troffic

CASE 17

Anchor poy I i mi t
(SeeNote1)
Beom Guordro i I poy

I i mit

end

GUARDRAIL PLACEMENT

------------------------------7--- --Curb foce extens i on

STANDARD PLAN C-2j

I i ne

APPROVED FOR PUBLICATION

One Woy Troffic

CASE 18

Revise Flair Rote Table.


REVISION

.....

Clifford E. Mansfield

6112198

DEPUTY STATE DESIGN ENGINEER

DATE

~~

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

BEAM GUARDRAIL PAY LIMIT

;:2
...,
:::>

25' NESTED W-BEAM

CJ)

0:::

<t:

1:

::!!:
:;,..:

6'-3"
TYP.

III

12'-6"

6'-3"
TYP.

.. I ..

t
___l

2'-3"

GROUND LINE

ELEVATION

CASE 19A
SPLICE IN CENTER

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BEAM GUARDRAIL PAY LIMIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

~-~-----------=--------6-._3-.. - - - -..I

. - - - - - -

37'-6"NE::.~;w_-_B-EA_M_~~~~~~~~~~~..~~-~~~~~~~-6--3-.. - - - -..-

- - - - - - - - - - - - - - ..
II

TYP.

TYP.

2'-3"

-----r~--------~--------~~--------~----~--------------~--------~~--------~-----___1
GROUND LINE

ELEVATION

CASE 19 B
SPLICE AT POSTS
SINGLE W-BEAM
RAIL ELEMENT

NESTED W-BEAM
RAIL ELEMENTS

APPROVED FOR PUBLICATION

SECTION

SECTION

....

Clifford E. Mansfield
STATE DESIGN ENGINEER

07-27-01
DATE

fJ'I Washington State Department of Transportation

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BEAM GUARDRAIL PAY LIMIT _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ______,_

~~~~~~~~N~D~~~~~~~

I1::::::.:-----

6'-3"
TYP.

'

18'-9"

-------------'~----

6'-3" -------1.
TYP.

t
___l

2'-3'

Ill

II

l1

II II

11

ill

II

GROUND LINE

ELEVATION

CASE20

SINGLE W-BEAM
RAIL ELEMENT

NESTED W-BEAM
RAIL ELEMENTS

GUARDRAIL PLACEMENT
18'-9" SPAN

SECTION

SECTION

STANDARD PLAN C-2n


APPROVED FOR PUBLICATION

....

Clifford E. Mansfield
STATE DESIGN ENGINEER

07-27-01
DATE

fJ'I Washington State Department of Transportation

NOTES

1. See Standard Plan C-1b for additional details.


2. One-way traffic layouts are identical to the two-way layout with
the exception that only the posts trailing the span need to be
CRT's with double blocks.
'
'
'
'
'

OBSTRUCTION

TWO-WAY TRAFFIC

TYPE 1 W-BEAM

100' OF NESTED W-BEAM RAIL ELEMENTS

TYPE 1 W-BEAM

PAY LIMIT

"BEAM GUARDRAIL PLACEMENT- 25' SPAN" PAY LIMIT

PAY LIMIT

PLAN

6'-3"-

TYP.

II

......
....

II

......
....

II

......
....

II

II

......
....

......
....

'\ '\)' )' )'

I-- 2' MIN.

6'-3"-

2'MIN.-

TYP.

II

II

II

II

II

II

''
''
''
''
''
''

''
''
''
''
''
''

''
''
''
''
''
''

''
''
''
''
''
''

''
''
''
''
''
''

''
''
''
''
''
''

II

......
....

......
....

II

......
....

II

......
....

II

......
....

'\ '\ '\)' )'

OBSTRUCTION
'

~----------------------------------~

CONTROLLED RELEASING TERMINAL (CRT) POSTS WITH TWO WOOD BLOCKS

TYPE 1 GUARDRAIL POSTS AND BLOCKS

II

TYPE 1 GUARDRAIL POSTS AND BLOCKS

ELEVATION

CASE 21
NESTED W-BEAM
RAIL ELEMENTS

6"x8"x14"
WOOD BLOCKS

~'

'
'

518" x 25" BUTTON HEAD BOLT

'

WITH 7132" OVAL GRIP, CUT


WASHER, AND HEX NUT

'
'
'
'
'

ONE-WAY TRAFFIC __.

'

OBSTRUCTION

~
ONE-WAY TRAFFIC LAYOUT

CRT POSTS WITH


TWO BLOCKS
(SEE NOTE 2)

CRT POST
APPROVED FOR PUBLICATION

SECTION

....

Clifford E. Mansfield
STATE DESIGN ENGINEER

07-13-01
DATE

fJ'I Washington State Department of Transportation

Transition Poy Limit


(See Note 1)
M ill!
__J-_1_____r--:-:--J___,
Bridge end~

NOTES
1o See Contract for transit i on ond connection typeo
2o The slope from the edge of the shoulder into the
foce of the guordroi I should not be steeper thon
10: L

CASE 22 C_

3 o Guordro i I i nsto I I ot ion sho I I be Beom Guordro i I


Type 1 with stondord post ond blocko
4, First letter of cose designation indicates end
treatment on side rood,
Second I etter i nd i cotes
end tr eotment on mo in rood,
For ins tonce o
terminal on the side rood ond o bridge connection
on the moin rood would be Cose 22 BC,
5, For terminal type ond detoi Is, see Contract ond
oppl icoble Stondord Plon(s),
5o Rodius dimensions shol I be etched into plote
rep I oc i ng the I etters "HHII shown on the
Identification Plote Detoi I,
Digits shol I be
1 1/ 2 MIN height ond 14 MAX width o
Plote shol I be golvonized ofter etching,
7, The guordroi I Identification Plote shol I be
mounted ot the I ower sp I ice bo It on the bock
side of the roi I element ot the PC of the
guordroi I rodius,

(See Note 4)

fQ_

Point B
Rod i us vories
(see Contract)

N
Q)

Terminal Poy Lim i t


(see Note 5)

0
_C

<(

11

Q)
Q)

lfl

+-

+-

CASE 22 D_

X Spoces
ot 5'- 3"
(1 spoce MIN)

-E
O_j

11

(See Note 4)

D
L 0
00_
::J
(_')~

PC
(See Note 7)

QJ

00_
Q)/-,

OJf-

+E
_j

Point A

Q_

Ln
Q)

+0

z
0

Q)
Q)

Ul

E
L
Q)

f-

CASE 22 A_

% DI A
11

Note 2

(See Note 4)

CASE 22 B_

hole

5"

1:74 ~1

~ ~

(See Note 4)

Sp I i c e

---+---+~--

bolt slot

Ro i I e I ement

lc
Identification
(see deto i I )

') :y,4
L

.I

1/411

Steel plote

GUARDRAIL PLACEMENT
STRONG POST
INTERSECTION DESIGN
STANDARD PLAN C-2p

>I

IDENTIFICATION PLATE DETAIL

SHEET 1 OF 1 SHEET

(See Note 5)

APPROVED FOR PUBLICATION

IDENTIFICATION PLATE MOUNTING DETAIL


(See Note 7)

....

Harold J. Peterfeso

0912003
DATE

CORRECTED REFERENCES TO NOTES.


REVISION

MHG
BY

STATE DESIGN ENGINEER

fJ'I Washington

10-31-03
DATE

State Department of Transportation

....1
....1

0
0

BEAM GUARDRAIL TRANSITION SECTION TYPE 1 - PAY LIMIT

::J

z
c:::
w

11..

BEAM GUARDRAIL
PAY LIMIT

NOTE

1.

FIVE SPACES @ 3' - 1 1/2" MAX.


SEE CONTRACT PLANS
FOR SPECIFIED
CONNECTION

Install Extruded Curb at face of Guardrail. See Standard Plan F-10.40 for details.

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B

12'- 6" NESTED THRIE BEAM


{12 GAGE)

{10 GAGE)

GROUND LINE
TERMINATE CURB
AT BRIDGE RAIL
OR BARRIER,
MATCH FACE

I
I
I
I
I
I
I
I
I
I

I
I
I

I
I
I
I
I

4" EXTRUDED CURB


SEE NOTE 1

I
I
I

I
I
I
I
I
I
I
I
I
I

:
1

_I

6'- 6" LONG, 10 x 10 POSTS


WITH 8 x 8 BLOCKS

~
--

TYPE 1

BEAM GUARDRAIL TRANSITION SECTION TYPE 1B- PAY LIMIT

6x8POSTWITH
~STANDARD
BLOCK

BEAM GUARDRAIL
TYPE 10 PAY LIMIT

'-"

6' - 6" LONG

FIVE SPACES@ 3'- 1 1/2" = 15'- 7 1/2"


SEE CONTRACT PLANS
FOR SPECIFIED

{TYP.)

I'

CONNECTION

12'- 6" NESTED THRIE BEAM


{12 GAGE)

'I'

BEAM GUARDRAIL TYPE 10

~~\~IE~~~~~~Ei~
r
_________
...----

TERMINATE CURB
AT BRIDGE RAIL
OR BARRIER,
MATCH FACE

.-----..;..-"'-"-'
I~~.!L...__ __.~
...,_,.___ _ ~
""'-------"'~
""'I _ _ _...,._,_
~~ ---~
~

4" EXTRUDED CURB


SEE NOTE 1
BEAM GUARDRAIL TRANSITION SECTION TYPE 1A- PAY LIMIT

BEAM GUARDRAIL
PAY LIMIT

12'- 6" NESTED THRIE BEAM {12 GAGE)

1
I

:
:

:
I

:
:

:
:

~ 6' - 6" LONG, 6 x 8 POST

:
:
I

:
~-~

6'-6"LONG,1010P~TYPE1B-

WITH STANDARD BLOCK


{TYP.)

'-

WITH 8 x 8 BLOCKS

FOUR SPACES @ 3' - 1 1/2" MAX.

SEE STANDARD PLAN C-24.10,


B OR E CONNECTION

GROUND LINE

.JO...;

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B
{10 GAGE)

GROUND LINE
TERMINATE CURB
AT BRIDGE RAIL
OR BARRIER,
MATCH FACE

I
I
I
I
I
I
I
I

4" EXTRUDED CURB


SEE NOTE 1

-~-1

8'- 0" LONG, 10 )( 10 POSTS


WITH 8 x 8 BLOCKS

;--~ ~--~
~
TYPE 1A

I
I
I

-,
'\..___

6x8POSTWITH
STANDARD BLOCK
{TYP.)

BEAM GUARDRAIL
TRANSITION SECTIONS
STANDARD PLAN C-3

6'- 6" LONG

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

BEAM GUARDRAIL TRANSITION SECTION TYPE 2- PAY LIMIT


SEE CONTRACT PLANS
FOR SPECIFIED
CONNECTION

12'- 6" NESTED W BEAM (12 GAGE)

FIVE SPACES @ 3' - 1 1/2" MAX.


12'- 6" NESTED W BEAM
(12 GAGE)

THREE SPACES @ 3' - 1 1/2"

BEAM GUARDRAIL

I
I
I
I

\ _

_;

I
I
I
I

SEE CONTRACT PLANS


FOR SPECIFIED
CONNECTION

I
1

6x8 POST WITH


STANDARD BLOCK
(TYP.)

\ _
1

:
_;

6'-6"LONG, 1010';:: __- _--(__


WITH BxB BLOCKS

BEAM GUARDRAIL
PAY LIMIT

BEAM GUARDRAIL TRANSITION SECTION TYPE 4


PAY LIMIT

BEAM GUARDRAIL
PAY LIMIT

6'- 0" LONG,


6x8 POST WITH
STANDARD BLOCK
(TYP.)

TYPE4

TYPE 2

FOR 45 MPH AND BELOW

BEAM GUARDRAIL TRANSITION SECTION TYPE 5- PAY LIMIT


FOUR SPACES@ 1'- 6 3/4"
TOTAL LENGTH= 6'- 3"

BEAM GUARDRAIL
PAY LIMIT

lWO SPACES@ 3'- 1 1/2"


TOTAL LENGTH= 6'- 3"

I
I

I
I
I
I

SEE CONTRACT PLANS


FOR SPECIFIED
CONNECTION

\ _ 6' - 0" LONG ' 6x8 POST


:
WITH STANDARD BLOCK
:
(TYP.)

TYPES

BEAM GUARDRAIL PAY LIMIT


6' - 3" POST SPACING

BEAM GUARDRAIL TRANSITION SECTION TYPE 6- PAY LIMIT


EIGHT SPACES @ 3' - 1 1/2" MAX.
TOTAL LENGTH= 25'- 0"

I I
I I

I
I

liII ilII
II
II
II
II
II

BEAM GUARDRAIL
PAY LIMIT

BEAM GUARDRAIL
TRANSITION SECTIONS

I
I
I
I

II
II
II
II
II

STANDARD PLAN C-3a

I
I

,~~ G-2 POST (TYP.)


SEE STD. PLAN C-1b

TYPES

~ WITH
6' - 0" LONG, 6x8 POST
STANDARD BLOCK

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

10-04-05
DATE

fJ'I Washington State Department of Transportation

BEAM G UARDRAIL T RANSITION SECTION TYPE 10


(N) SECTIONS OF
12' - 6" THRIE BEAM
(10 GAGE)

SEE TRAILING END


TRANSITION DETAILS

12'- 6" NESTED THRIE BEAM (12 GAGE)


FOUR SPACES @ 3' - 1 1/2" MAX.

SEE CONTRACT PLANS


FOR QUANTITY

SEE NOTE 1

..

BEAM GUARDRAIL

PAY LIMIT

NOTES

PAY LIMIT

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B

(10 GAGE)

BRIDGE
4" EXTRUDED CURB
SEE NOTE 2

-Y

"")..

IIIII I I

~
Ill Ill

Ill II II

IIIII

IIIII

6'- 6" LONG, 10 x 10 POST WITH


STANDARD BLOCK (TYP.)

::J

When thrie beam is installed at the face of the bridge curb,


install Extruded Curb at face of Guardrail. See Standard
Plan F-10.40 for details. Match the height of existing
bridge curb with a 20H : 1V transition.

3.

When thrie beam is installed at the face of rigid bridge rail, an


HMA ramp is required from the roadway surface to the top of
the bridge curb or sidewalk. The slope of the ramp shall be
20H : 1V or flatter.

IIIII

...J
...J

LLJ
Cl
Cl

2.

@ 3'- 1 1/2"

1 ..

If the distance from the end of the bridge to the end of the
thrie beam bridge rail section exceeds 6' - 3" using 12' - 6" thrie
beam sections, add a 6' - 3" section of thrie beam bridge rail
to reduce the length to less than 6' - 3".

lWO SPACES

VARIES 3" TO 2' - 5"

1.

0::

6 X 8 POST WITH
STANDARD BLOCK
(TYP.)

TYPE10
APPROACH END
THRIE BEAM INSTALLED AT FACE OF BRIDGE CURB

LLJ
LL.

BEAM GUARDRAIL TRANSITION SECTION TYPE 11- PAY LIMIT

BEAM GUARDRAIL
PAY LIMIT

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B

(10 GAGE)
lWO SPACES

12' - 6" NESTED THRIE BEAM


(12 GAGE)
FOUR SPACES MIN. @ 3' - 1 1/2" MAX.

@ 3'- 1 1/2"

I
I
I
I
I
I

I
I
I
I
I
I

BRIDGE

6 x 8 POST WITH__/"! i
STANDARD BLOCK
: :
(TYP.)
: :
I

PAY LIMIT

12'- 6" NESTED THRIE BEAM


(12 GAGE)

FOUR SPACES @ 3' - 1 1/2"


BEAM GUARDRAIL

THRIE BEAM GUARDRAIL


REDUCER SECTION TYPE B

THREE SPACES

(10 GAGE)

@ 3' - 1 1/2" MAX.

I
I
I
I
I
I
I
I
I

I
I
I
I
I

6 X 8 POST WITH
STANDARD BLOCK
(TYP.)

_/
1

4" EXTRUDED CURB


SEE NOTE 2

c_~

6'-6" LONG

I
I
I

~-~
TYPE12

6'- 6" LONG, 10 x 10 POST WITH


STANDARD BLOCK (TYP.)

2' - 6" TO 6' - 3"

BRIDGE

I
I
I
I

TYPE 11

TRAILING END
THRIE BEAM INSTALLED AT FACE OF BRIDGE CURB

4" EXTRUDED CURB


SEE NOTE 2

6'-6"LONG~

BEAM GUARDRAIL TRANSITION SECTION TYPE 12- PAY LIMIT

BEAM GUARDRAIL

2'- 6"
MAX.

BEAM GUARDRAIL
TRANSITION SECTIONS
STANDARD PLAN C-3b
SHEET 1 OF 2 SHEETS

6'- 6" LONG, 10 x 10 POST WITH


STANDARD BLOCK (TYP.)

TRAILING END
THRIE BEAM INSTALLED AT FACE OF BRIDGE CURB

APPROVED FOR PUBLICATION

06-27-11

Pasco Bakotich Ill

fll
.....

STATE DESIGN ENGINEER

DATE

Washington State Department o Transportation

12'- 6" NESTED THRIE BEAM (12 GAGE)


FOUR SPACES @ 3' - 1 1/2" MAX.

SEE NOTE 1

BEAM GUARDRAIL TRANSITION SECTION TYPE 13

(N) SECTIONS OF
12'- 6" THRIE BEAM
(10 GAGE)
SEE CONTRACT PLANS
FOR QUANTITY

SEE TRAILING END


TRANSITION DETAILS

BEAM GUARDRAIL

PAY LIMIT

PAY LIMIT

THRIE BEAM GUARDRAIL REDUCER SECTION TYPE A


(10 GAGE)

I" VARIES 3" TO 2'- 5"

6'- 3"

TWO SPACES
@ 3'- 1 1/2"

BRIDGE

..,._

I IIIII

IIIII I

11111111

I
I
I
I
I
I
I
I
I
I
I
I
I

HMARAMP
SEE NOTE 3

...J
...J

STANDARD BLOCK (TYP.)

Cl
Cl

1111

1111
I
I
I
I
I
I
I
I
I
I
I

I
I
I
I
I
I
I
I
I
I
I
I
I

BEAM GUARDRAIL

APPROACH END

PAY LIMIT

LLJ

THRIE BEAM INSTALLED AT FACE OF BRIDGE RAIL

0::
LL.

~ 6 x 8 POST WITH
1

STANDARD BLOCK
(TYP.)

~-J

TYPE13

::J

I
I
I
I
I
I

: :

6~-~

6'- 6" LONG, 10 x 10 POST WITH

LLJ

~II I

II I

BEAM GUARDRAIL TRANSITION SECTION TYPE 14- PAY LIMIT

12' - 6" NESTED THRIE BEAM


(12 GAGE)

THRIE BEAM GUARDRAIL REDUCER SECTION TYPE A

(10 GAGE)

6'- 3"

2'- 6"

FOUR SPACES @ 3' - 1 1/2" MAX.

TWO SPACES

@ 3'- 1 1/2"

MAX.

Cl

I
I
I
I
I
I

I
I
I
I
I
I

6 x 8 POST WITH~

I
I
I
I
I
I

I
I
I
I
I
I

STANDARD BLOCK
(TYP.)

: :
: :
I

I
I

6'-6"LO~~

I
I
I
I
I
I
I
I
I
I

~-~

TYPE 14

BRIDGE
HMA RAMP
SEE NOTE 3

6'- 6" LONG, 10 x 10 POST WITH


STANDARD BLOCK (TYP.)

TRAILING END
THRIE BEAM INSTALLED AT FACE OF BRIDGE RAIL
BEAM GUARDRAIL TRANSITION SECTION TYPE 15- PAY LIMIT

BEAM GUARDRAIL
PAY LIMIT

THRIE BEAM GUARDRAIL REDUCER SECTION TYPE A


(10 GAGE)
FOUR SPACES @ 3' - 1 1/2"

12'- 6" NESTED THRIE BEAM


(12 GAGE)
THREE SPACES

2' - 6" TO 6' - 3"

@ 3'- 1 1/2" MAX.

I
I
I
I
I
I
I
I
I

6 x 8 POST WITH
,.,...-: :
STANDARD BLOCK __/
: :
(TYP.)

I
I
I
I
I
I
I

I
I
I
I
I

I
I
I
I

:
i

I
I

~- 6" LON~,:<<

.-TYPE15

TRAILING END
THRIE BEAM INSTALLED AT FACE OF BRIDGE RAIL

BRIDGE
HMA RAMP
SEE NOTE 3

BEAM GUARDRAIL
TRANSITION SECTIONS
STANDARD PLAN C-3b
SHEET 2 OF 2 SHEETS

~-~ 6'- 6" LONG, 10 x 10 POST WITH


STANDARD BLOCK (TYP.)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-27-11
DATE

Washington State Department of Transportation

NOTES

BRIDGE COLUMN
BEAM GUARDRAIL
TYPE 11

BEAM GUARDRAIL TRANSITION SECTION TYPE 16- PAY LIMIT

PAY LIMIT
SEE NOTE 1

1.

See Contract for the number of thrie beam sections for Beam Guardrail Type 11.

2.

If the distance from the end of the Beam Guardrail Type 11 to the column/structure
exceeds 6'- 3" using 12'- 6" thrie beam sections, add a 6'- 3" nested section of
thrie beam to reduce the distance to less than 6' - 3".

3.

Install Extruded Curb (See Standard Plan F-10.40) at face of Guardrail.

BEAM GUARDRAIL
PAY LIMIT

FOUR SPACES @ 3' - 1 1/2" MAX.

TWO SPACES

12'- 6" NESTED THRIE BEAM

THRIE BEAM GUARDRAIL

@ 3' - 1 1/2" MAX.

REDUCER SECTION TYPE B


10 GAGE

SEE NOTE 4

I
I
I

I
I
I
I
I
I

LLJ
Cl
Cl

::J

0::

LLJ
LL.

BRIDGE COLUMN

I
I
I
I
I
I
I

I
I
I
I
I
I
I
I

...J
...J

4. Attach the standard block to the rail using two 5/8" x 4" lag bolts.

c_~

BEAM GUARDRAIL

~ 6
_;

BEAM GUARDRAIL TRANSITION SECTION TYPE 17- PAY LIMIT


12'- 6" NESTED THRIE BEAM

TWO SPACES
@ 3'- 1 1/2" MAX.
THRIE BEAM GUARDRAIL

6'- 6" LONG, 10 X 10 POST


WITH STANDARD BLOCK
(TYP.)

PAY LIMIT
SEE NOTES 1 & 2

PAY LIMIT

8 POST WITH
STANDARD BLOCK
(TYP.)
X

BEAM GUARDRAIL
TYPE 11

6'- 6" LONG


4" EXTRUDED CURB
SEE NOTE 3

4'- 0" MAX.

FOUR SPACES @ 3' - 1 1/2" MAX.

REDUCER SECTION TYPE B


10 GAGE

SEE NOTE 4

TYPE16
APPROACH END

I
I
I
I
I

I
I
I
I
I

/1
6 x 8 POST WITH
STANDARD BLOCK __/ ~

-~

(TYP.)
6' - 6" LONG

4" EXTRUDED CURB


SEE NOTE 3

6'- 6" LONG, 10 X 10 POST


WITH STANDARD BLOCK
(TYP.)

BRIDGE COLUMN

PAY LIMIT
FOUR SPACES@ 3'- 1 1/2" MAX.

BEAM GUARDRAIL

THRIE BEAM GUARDRAIL

TWO SPACES
@ 3' - 1 1/2" MAX.

I
I
I
I
I
I
I

_)

TRAILING END

4' - 0" TO 6' - 3"


SEE NOTE 4

I
I
I
I

I
I
I

BEAM GUARDRAIL
TRANSITION SECTIONS

I
I
I
I
I

c_J

TYPE17

I
I
I

PAY LIMIT
SEE NOTES 1 & 2

12'- 6" NESTED THRIE BEAM

REDUCER SECTION TYPE B


10 GAGE

6 x 8 POST WITH
STANDARD BLOCK
(TYP.)

BEAM GUARDRAIL
TYPE 11

BEAM GUARDRAIL TRANSITION SECTION TYPE 18- PAY LIMIT

BEAM GUARDRAIL

6'-6"LONG~
TYPE18
TRAILING END

--~ 6'- 6" LONG, 10

X 10 POST
WITH STANDARD BLOCK

4" EXTRUDED CURB


SEE NOTE 3

STANDARD PLAN C-3c


SHEET 1 OF 1 SHEET

(TYP.)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-27-11
DATE

Washington State Department of Transportation

BEAM GUARDRAIL
PAY LIMIT

FLARED TERMINAL PAY LIMIT (SEE NOTES 1 AND 2)

10'- 0" MIN.

NOTES
EDGE OF WIDENED
EMBANKMENT

1. Unless otherwise indicated in the contract, the SRT - 350 (12.5, 8 Post}
as manufactured by Trinity Industries, Inc., or a FLEAT 350 as
manufactured by Road Systems Inc., shall be installed per manufacturer's
recommendations. If specified in the Contract, the FLEAT TL2
as manufactured by Road Systems, Inc. shall be installed per
manufacturers recommendations.
2. Where terminal is placed on a curve, and post offsets would result in the
rail encroaching onto the shoulder (e.g., the inside of a curve}, the posts
shall be installed so that the faceof the rail is at the edge of the shoulder.
3. When snow load post washers and snow load rail washers are called for
in the contract, the snow load rail washers must be omitted within the
terminal limits.
4. Offset distances:
FLEAT 350 ............................................... 4'- 0"

:)~

ITI
'
'
'
'
'
'
'
~

18

'
'
'
'
'
'
'

''
'~"'
L,

' '
'~"'
L,

' '
'~"'

''
''
''
~

' '
' '
' '
~

18

L,

' '
'~"'
L,

''
'~"'

' '
' '
' '
~

' '
' '
' '
~

''
''
''
~

L,

Q--1~

"

'
'
'
'

'
'
'
'

L"'

FLEAT TL2 ............................................... 1'- 8" minimum

~
-.

GROUND LINE

"

OL .J

'
'
'
'

'
'
'
'

ELEVATION VIEW

FLEAT OPTION

BEAM GUARDRAIL
PAY LIMIT

FLARED TERMINAL PAY LIMIT (SEE NOTES 1 AND 2)

10'- 0" MIN.

EDGE OF WIDENED
EMBANKMENT

20H:1V SLOPE MAX.

b
'

(RELATIVE TO GRADE)

110H:1V SLOPE MAX.


-----------------

TANGENT LINE

L------------~PLANVIEW

BEAM GUARDRAIL
FLARED TERMINAL
STANDARD PLAN C-4b
'
'
'
'
'
'
'
~

'
'
'
'
'
'
'

' '
'~"'
L,

''
'~"'

' '
' '
' '
~

''
''
''
~

L,

I
I

I
I

!...J
L_,

I
I
I

I
I
I

I
I

I
I

!...J
L_,

I
I
I

I
I
I

' '
'~"'

''
'~"'

.......

L,

' '
' '
' '
~

''
''
''
~

L,

....
\ "''
~
' '

.......
IL
\

GROUND LINE

SHEET 1 OF 1 SHEET

.J

'

APPROVED FOR PUBLICATION

~ :
' '

Harold J. Peterfeso

ELEVATION VIEW

04/2006

SRTOPTION

DATE

Rev;sed FLEAT Flare Lengths


REVISION

AMC

BY

.....

STATE DESIGN ENGINEER

fJ'I Washington

06-08-06
DATE

State Department of Transportation

NOTES
1. An ET-PLUS (TL3) as manufactured by Trinity Industries, Inc. or
an SKT-350 as manufactured by Road Systems Inc. shall be installed
according to manufacturer's recommendations. When a TL2 terminal is
specified in the contract an ET-PLUS (TL2) as manufactured by
Trinity Industries, Inc., or an SKT-TL2 as manufactured by Road
Systems, Inc. shall be installed according to manufacturer's
recommendations.
2. A reflectorized object marker shall be installed according to
manufacturer's recommendations.
3. When snow load post washers and snow load rail washers are required
by the contract, the snow load rail washers must not be installed within
the terminal limits.
4. Terminal shall be installed at a taper, ensuring that end piece is entirely
off shoulder.
5. Length for ET-PLUS (TL3) and SKT-350 is 50'. Length for
ET-PLUS (TL2) and SKT-TL2 is 25'.
BEAM GUARDRAIL
PAY LIMIT

NON-FLARED TERMINAL PAY LIMIT (SEE NOTE 1)

10' MIN

(SEE NOTES 4 & 5)


EDGE OF WIDENED
EMBANKMENT

J~

lXI

.,.20: 1 SLOPE OR FLATTER


(RELATIVE TO GRADE)

6:1 iAPER

' 10:1 SLOPE OR FLATTER


EDGE OF SHOULDER

PLAN

SEE NOTE 2

~c

10-0
00
'0

10-0
00

10-00
0

00
I~-

10-0
00

- ""0"~0"'- -- J[

__ ~II
GROUND LINE

'A~ ~ ~

'"

BEAM GUARDRAIL
NON-FLARED TERMINAL
STANDARD PLAN C-4e

ELEVATION

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

0112003
DATE

REV I SED NOTES 1 8. S1 ADDEO SLOPES.


REVISION

RG

BY

STATE DESIGN ENGINEER

02-20-03
DATE

fJ'I Washington State Department of Transportation

....1
....1

0
0

::J

z
c:::

BEAM GUARDRAIL BULL NOSE TERMINAL BID ITEM


3'- 2 3/4"

37'- 6"

12'- 2"

11..

6'- 3"

6'- 3"

7L

6'- 3"

9L

8L

6'- 3"

6'- 3"

10L

11L

10'

65'

25'

12L
/
/
/

/
/

SYMMETRICAL ABOUT THE CENTERLINE

---,-/

STD. POSTS AND


BLOCKS (TYP.)
7R

8R

9R

10R

11R

''

''

''

NORMAL MEDIAN SLOPE


12'- 6" RAIL LENGTH
12'- 6" ARC LENGTH
AT FACE OF RAIL
(SLOTTED RAIL
ELEMENT#1)

(SLOTTED RAIL
ELEMENT#3
12'- 6" ARC LENGTH
AT FACE OF RAIL
(SLOTTED RAIL
ELEMENT#2)

25' - 0" (TYP.)

W-BEAM OR THRIE BEAM


GUARDRAIL (SEE CONTRACT)
(SEE NOTE 1) (TYP.)

STANDARD THRIE BEAM RAIL ELEMENTS


SEE STANDARD PLAN C-1a

SLOPE NOT STEEPER


THAN 10H : 1V (TYP.)

EDGE OF
SHOULDER (TYP.)

BULL NOSE GRADING PLAN

PLAN
BEAM GUARDRAIL BULL NOSE TERMINAL - DESIGN 1
NOTE

1. For W-Beam applications extend the rail from the bullnose


terminal by using a "Reducer Element Type C" followed by
a standard Post and Block, spaced at 3'- 1 1/2".
Continue runs with standard 6' - 3" post spacing.
For additional Details see Standard Plans C-20.10
and C-25.20.

BEAM GUARDRAIL BULL NOSE TERMINAL BID ITEM


3'- 2 3/4"

37'- 6"

12'- 1"

6'- 3"

6'- 3"

6'- 3"

6'- 3"

6'- 3"

i1==15~-i
~

10L

9L

11L

12L

""'
b

7L

SYMMETRICAL ABOUT THE CENTERLINE

STD. POSTS AND


BLOCKS (TYP.)

7R

9R

12' - 6" ARC LENGTH


AT FACE OF RAIL
(SLOTTED RAIL
ELEMENT#1)

15

11R

::;:::~~~~-~'~'RA~IL~LE~N~GfT~H~--~~==~~~~~~~~~~~~;:::~::::::L:::~;;;,;~~~~~~::::::

12'- 6" ARC LENGTH


AT FACE OF RAIL
(SLOTTED RAIL
ELEMENT#2)

12

10R

(SLOTTED RAIL
ELEMENT #3)

25' - 0" (TYP.)

STANDARD THRIE BEAM RAIL ELEMENTS


SEE STANDARD PLAN C- a
1

PLAN
BEAM GUARDRAIL BULL NOSE TERMINAL- DESIGN 2

W-BEAM OR THRIE BEAM

UARDRAIL (SEE CONTRACT)


(SEE NOTE 1) (TYP.)

BEAM GUARDRAIL
BULL NOSE TERMINAL
STANDARD PLAN C-4f
SHEET 1 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

---~s=~=T~ED=E=SIG=N=E~NG=IN-EE_R_ __ _

0712112
DATE

~ Washington State Department of Transportation

....1
....1

0
0

::J

z
c:::
w

11..

B"NOM;~A~
______
GUARDRAIL BOLT
5/8" DIAM. x 10" LONG

B"NOMI~

1"

TAPERED
BLOCK

THRIEBEAM
W-BEAM WOOD BLOCK
OR WOOD POSTS
STANDARD PLAN C-1b

GUARDRAIL BOLT

518, DIAM. x 17" LONG

~EE

THRIE BEAM

~NOM~~~

TAPERED
BLOCK

W-BEAM WOOD BLOCK


FOR WOOD POSTS
SEE STANDARD PLAN C-1b

GUARDRAIL BOLT

518, DIAM. x 17" LONG


THRIE BEAM

5/8" x 9" BOLT


NUT AND WASHER
5/8" x 9" BOLT
NUT AND WASHER

THRIE BEAM

THRIE BEAM
WOOD 6"x8"
POST

YA -

FOUN~.ATION

6'- 0" STEEL


~ TUBETS8"x0.1875

3 1/2" DIAM. HOLES

POST
1R&1L

POST
2R&2L

NOTE : CABLE BEARING


PLATE NOT SHOWN

b
.....

POST
3RT08R
3L TOBL

POST
9RTO 12R
9L TO 12L

BEAM GUARDRAIL
BULL NOSE TERMINAL
STANDARD PLAN C-4f
SHEET 2 OF 4 SHEETS

APPROVED FOR PUBLICATION

TAPERED BLOCK

Pasco Bakotich Ill


STATE DESIGN ENGINEER

071~!2

Washington State Department of Transportation

"COLD TUFF"
BUTTONS

....1
....1

12 5/8"

0
0

NOSE CABLES

ANCHOR PLATE

::J

z
c:::

11..

2 7/8"

15'- 0"

I
--j

I'
'I
~//////////~~

~~

--\_

FOR 5/8" DIAM. WIRE ROPE

15/16"

4 1/4"

2 1/16"

-1

~--~~-----~~---~

.-------+----+-------!-------!--------, _11 3/16"

2 7/8"

5/8" DIAM. STEEL


WIRE ROPE

13/16"

STEEL PLATE, ASTM A36


12 5/8" X 5 7/8" X 3/16"

Ir-

14' _ 6 1/4"

NOSE CABLE

POST3

POST2

POST 1

CABLE ANCHOR & BRACKET ASSEMBLY


FOR ANCHOR PLATE, CABLE END PLATE, AND
ANCHOR CABLE - SEE STANDARD PLAN C-6f

5/8" x 1 1/4" BUTTON HEAD


SPLICE BOLT AND NUT {TYP.)

3/4" CABLE
CLAMP

15/16" X 1 3/16"
SLOT {TYP.)

1 1/4"

5/8" NOSE
CABLE

NOSE CABLE ANCHOR PLATE

5/16" DIAM.
HOLE {TYP.)

THREAD
1/4"

20

H~NUT\

R 5/8"

~r-

~-f~

ANCHOR CABLE AND PLATE,


SEE STANDARD PLAN C-6f

NOSE CABLE
ANCHOR PLATE

U-BOLT- 1/4" DIAM.


2 1/2" LONG

U-BOLT PLATE WASHER


THE U-BOLT SHALL BE MADE FROM ASTM A307
STEEL AND GALVANIZED ACCORDING TO
STANDARD SPEC. 9-16.3(3).

2L

THE U-BOLT PLATE WASHER SHALL BE MADE FROM


ASTM A36 OR A36M PLATE STEEL, AND GALVANIZED
ACCORDING TO STANDARD SPEC. 9-16.3(3).

THE NUT SHALL BE ASTM A563D STEEL,


AND GALVANIZED ACCORDING TO
STANDARD SPEC. 9-16.3(3).
NOSE CABLE,
2 REQUIRED
POST 1L AND 1R

CABLE BEARING PLATE

2R

3R

NOSE CABLE
ANCHOR PLATE

rr

STEEL
FOUNDATION
TUBE

NOSE CABLE ASSEMBLY


ANCHOR CABLE AND PLATE,
SEE STANDARD PLAN C-6f

SECTION
PLAN - THRIE BEAM NOSE

BEAM GUARDRAIL
BULL NOSE TERMINAL
STANDARD PLAN C-4f
SHEET 3 OF 4 SHEETS

U-BOLT CABLE CLIP ASSEMBLY


SECTION

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


0712112
-----------------------STATE DESIGN ENGINEER
DATE
~ Washington State Department of Transportation

....1
....1

0
0

::J

3/8'~

6'- 3"

6 1/4"

z
c:::

9 1/4"

l8"
11

11

10"

11..

2" ---

10"

I--

2" ---

I
0

!I

c:p
0

1" ---

r-

3/8" DIAM. U - BOLT


HOLES (TYP.)

~r.------~t)

POST BOLT
SLOT

13 3/4"

Lst8~' R. (TYP.)

SPLICE
SLOT

3/8"

8 1/8"

11

4a.

....---------------------,\+)

~R.~J

\
\
\ _ SLOT B (TYP.)
-SEE DETAIL

3/8"

ltL

40 5/8"
(TYP.) EACH END

3/4"

L's,8:. R. (TYP.)

SLOT D DETAIL

6'- 3"
8 7/8"

3/8"

I
I

11"

11
1~
_;(E+=======:::DJ

3/4"

SLOT C DETAIL

3/4"

SLOT B DETAIL

6 1/4"

11

11

3/8"

R. (TYP.)

1'8"

3/4"

)tll"====:::]JJ

L_

c:p

26 3/4"

SLOT A DETAIL

27 1/2"

3/8:

4"

8 7/8"

4"

8 7/8"

4"

8 7/8"

4"

4" ~- 7/16"

8 7/8"

SLOT B (TYP.)
-SEE DETAIL

12'- 6"

c:p

SLOTTED THRIE BEAM RAIL ELEMENT #1

c:J

7'71

L_L_o

!
q

SEE STANDARD PLAN C-1a FOR RAIL ELEMENT DETAILS


(RAIL DIMENSIONS SHOWN ARE BEFORE BENDING TO RADIUS SHOWN IN PLAN)

POST BO
SL

c:p
0

\_ SPLICE BOLT SLOT

12'- 6"

L SLOT

(TYP.)
-SEE DETAIL

SLOTTED THRIE BEAM RAIL ELEMENT #2


SEE STANDARD PLAN C-1a FOR RAIL ELEMENT DETAILS
(RAIL DIMENSIONS SHOWN ARE BEFORE BENDING TO RADIUS SHOWN IN PLAN)

6'- 3"

6 1/4"
11 3/4"

9 7/8"

11 3/4"

9 7/8"

11 3/4"

10 1/4"

POST B
SLOT (

i
0

c:p

2
~

c:p

ci

7o

\_ SPLICE BOLT
SLOT (TYP.)

\
12'- 6"

SLOTTED THRIE BEAM RAIL ELEMENT #3


SEE STANDARD PLAN C-1a FOR RAIL ELEMENT DETAILS

\
\__SLOT D (TYP.)
-SEE DETAIL

\_POST BOLT
SLOT (TYP.)

BEAM GUARDRAIL
BULL NOSE TERMINAL

STANDARD PLAN C-4f


SHEET 4 OF 4 SHEETS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

NOTES

Anchor coble

5xB Timber posts--------~


to motch beom
guordro i I

Anchor p I ote moy be constructed from 1 /~" pI otes


welded to equol strength ond d i mens i ons os shown,

2o

For end section de to i Is see Stondord PI on "Beam


Guordro i I End Sect i ons",

3o

For post deto i Is , see Stondord PI on "Beom Guordro i I


Posts ond Blocks"o

4o

E i ght%" x 1 1/ 2 " mach i ne bolts w i th hex nut ond


wosher,
PI oce washer on foce s i de of ro i I o

5o

Outside nut sho I I be torqued ogo i nst


minimum of 100ft- lbso

(see Deto i I)

End section Design G


(see Note 2)

CRT Post
(see Note

1,

PLAN

i ns i de nut o

Toeno i I beor i ng plote w i th 10d no i I ot corners to


prevent turn i ngo

Beom Guordroi
poy I imit

Anchor poy

I i mit

(see Note 7)
Anchor poy I i mit does not opp I y when anchor
i ncluded i n o Beom Guordro i I Term i nal o

is

%" x 2" Button heod bo It or


%" x 1 1/ 2 " hex heod bo It ond
hex nut w i th ro i I onchor woshers
under bo It heod ond nut~

5'-3"
/Anchor pI ote
(see deto i Is)

Two 1" nuts


ond woshers
(see Note 5)

Anchor ro i I wosher
(see Deto i I )

Beor i ng plote (see


Deto i I ond Note 5)

Stondord 2" ID
p i pe sleeve

1/l~'!!l-2

(2%" 00)

Two 1" nuts


ond woshers
(see Note 5)

<t

::;;:

BEAM GUARDRAIL ANCHOR


TYPE 1

CRT Post
(see Note 3)
Anchor post assembly
(See Note 3)

TI

0
TYPE 1

STANDARD PLAN C-6

ANCHOR

APPROVED FOR PUBLICATION

Donald K. Nelson

05130197

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

Sheet 1 of 2 Sheets

l:?u ~lc

15"

LJ"

~lc

~lc

LJ"

LJ"

.....

~v:
e

/'--' 1/4

-------------- -

%"R
%" R

~~~

~~~

Note Ll

-------------- -------------- -------------- -------------- -

ft

ill

Hole (e1ght requ1redl


3"

311

2 /~"

""""
""

1/ 2 " End pI ote

J
I

SECTION

ELEVATION

1112'' 11112''

~~--ittr~;f!
li!J 1

B-B

Goge MIN

ANCHOR PLATE
(See Note 1)

''

ANCHOR RAIL WASHER


3
~5" X 1" X 8" plote-~
tock we I ded to %" pI ote

I:LJ"

:1,

1
~~~

-----------

%"

BEAM GUARDRAIL ANCHOR


TYPE 1

Cob I e

Swoge

%" Stee I pI ote

BEARING PLATE
1" x 7" Stud
threaded fu I I
length (TYPl

STANDARD PLAN C-6

ANCHOR CABLE

APPROVED FOR PUBLICATION

_ _D_o_n_a_ld_K_._N_e_ls_o_n___ 05130197
STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

Sheet 2 of 2 Sheets

(/)

W8

w
w

x 18 STEEL POST

NOTES

0::

1. Rail section and W8 x 18 steel post shall be fabricated to receive 5/8" hex head
bolts as shown .

IIl
....1
....1

iii
5/8" HEX HEAD BOLTS

2. All bolts shall be high strength 5/8" hex head bolts with anchor rail washers.

W8 x 18 STEEL POST
1/2" ANCHOR PLATE

SEE NOTE 1

~
~

C")

W-BEAM GUARDRAIL

W-BEAM
GUARDRAIL

4" (TYP.)

2 3/4"

C")

PLAN
W-BEAM GUARDRAIL

ONE 1 3/4" X 5 1/4" X 0.188"


WASHER WITH TWO 11/16" HOLES

'i7

~f

1/2" ANCHOR
PLATE

t>

1. vii

,I>

~~'I"' ."t>

SECTION

I>

I>

SEE NOTE 2

..

(.)

0::
0

30"

::::i

(/)

1 1/4"

2"

:Z
~

+-+
I

+-4- +-4-+---+-L~
I
I

COMMERCIAL CONCRETE
.

I>

+-+

"' .....I I
t~o
. ~~ 'II
.. 1 It> . .

__.___--;,~--.--...,"' L '.JI~ .J ~

r
ELEVATION

BEAM GUARDRAIL ANCHOR


TYPE2

..

."

BACKING PLATE

6'- 0" POST


(OR 3' - 0" MIN. IN SOLID ROCK)

~.

..

..

"

STANDARD PLAN C-6a

I>
p

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

18" DIAM.

Pasco Bakotich Ill

f - - - - ---------1

ISOMETRIC

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

NOTES
1. For details, see Standard Plan C-6.
ANCHOR PAY LIMIT

BEAM GUARDRAIL
PAY LIMIT

6 -3
1

2. For end section details see Standard Plan C-7 or C-7a.

11

3. For details, see Standard Plan C-1 b.

18

11

ANCHOR PLATE
TYP (SEE NOTE 1)

ANCHOR RAIL WASHER


(SEE NOTE 1)

4. Outside nut shall be torqued against inside nut a minimum of


100 ft.-lbs.
5. Post and block shall match beam guardrail posts.

END SECTION DESIGN C


(SEE NOTE 2)
Co'I>

211 ID PIPE
SLEEVE (2 3/8 OD)

~--STANDARD

TWO 111 NUTS


AND WASHERS TYP

II

~~~'l.JZ(S0EIX\EIZN720~T;s:E"!J,4TfL)'l5_~~'l!IL~~~in~1;------ (SEE
BEARING PLATE
NOTE 1)

[2

SEE NOTE 5

'------ TWO 111 NUTS AND


WASHERS (SEE NOTE 4)

W BEAM INSTALLATION

0
ANCHOR PAY LIMIT

THRIE BEAM GUARDRAIL


PAY LIMIT

6 -3
1

12

to
I

"-------ANCHOR POST ASSEMBLY


(SEE NOTE 3)

11

18

11

I_~--~- __:__-~

11

ANCHOR RAIL WASHER


(SEE NOTE 1)

END SECTION DESIGN C


(THRIE BEAM) (SEE NOTE 2)
_j

~~~~~~~~~~~~W~O~~~~~~~=R~:~~~~~~~~W~~:~~~O;S~T~~~~~~~~#~~~~~~~~~S~NDARDTIDPIPE
(SEE NOTE 3)

SLEEVE (2 3/8 OD)


PLATE
(SEE NOTE 1)
II

~---BEARING

'------ TWO 111 NUTS AND


WASHERS (SEE NOTE 4)

THRIE BEAM INSTALLATION


'-------ANCHOR POST ASSEMBLY
(SEE NOTE 3)
APPROVED FOR PUBLICATION

Clifford E. Mansfield

rI

12199
DATE

!MODIFIED "END SECTIONS" TO DESIGN "C", CHANGEQ TWS


INOTE 2 AND DETAIL TITLES.
I
I
REVISION
I BY

. . . . . DEPUlY STATE DESIGN ENGINEER

fl'l

01106100
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

NOTES

14 "

x 9'-

o"

1,

At t o c h W- b eo m t o s tee I p i p e wi t h %" x 1 1/ 4 "


button heod bolt wi th no wosher,
No connect i on to
the post i s requ i red,

2,

For end sect i on de to i Is see Stondord PI on, "Beom


Guordro i I End Sections",

3,

For deto i Is see Stondord PI on, "Beom Guordro i I


Anchor Type 1",

LJ,

For deto i Is see Stondord PI on, "Beom Guordro i I

5,

Outs i de nut sho I I be torqued ogo i nst ins i de nut o


min i mum of 100 ft/lbs,

Cob I e wi th one swoged end

See Detoi

'------- 1 o" x 13"

Stondord steel pipe

See Note 1

%" x 2" Button heod bo It


or %" x 11/ 2 " hex heod bo It
ond hex nut wi th onchor ro i
woshers under bolt heod ond
nut !See Note 3),
Beom guordro i
poy I im i t

Anchor poy I i mi t
Tock weld 2 1/2 (( X 2 1/2 (( X lj4(( steel plote
u
wi th 1 /15 hole to tubulor steel

Anchor plote
(see Note 3)

Two 1" Nuts


ond washers
(see Note 5)

Nut
1" X LJ"
Stud threaded fu I I length

End Sect i on Des i gn G


lsee Note 2)

DETAIL B
%"Coble clips 15 required)
torque nuts to 50 ft/lbs,
Bearing plote (see Note 3)
Stondord 2" ID p i pe sleeve
12%" 00)

BEAM GUARDRAIL ANCHOR


TYPE 5

Two 1" Nuts ond wosher


(see Note 5)

Anchor Post Assemb I i es


(see Note LJ)

----~

0
TYPE 5 ANCHOR

STANDARD PLAN C-6d


APPROVED FOR PUBLICATION

Donald K. Nelson

----------------

STATE DESIGN ENGINEER

05130197
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

NOTES
1,

For deto i Is, see Stondord Pion, "Beom Guordro i I


Anchor Type 1",

')

The ro i I e I ement i s to be included in the "Beom


Guordro i I" poy item,
The "Anchor" poy i tem
i ncludes the onchor post, onchor plote, onchor
coble , beoring plote , nuts ond woshers ,

'-

Beom Guordro i I poy I i mi t

Two 1" nuts


ond woshers
(see' Note 1) ~
,-------'
:

'
'

rr1

--~
__

_j

3,

For de to i Is, see Stondord PI on, "Beom Guordro i


Posts ond Blocks" ,

4,

Post sho I I motch beom guordro i I posts,

(see Note 2)

Anchor plote
(see Note 1)
'

-------------------~

'
'

------------------~?

--------------------~

''

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _j

Beor i ng plote
(see Note 1)

Stondord 2"
p i pe sleeve

111.:::-1112:

(2%" 00)

Two 1" nuts


ond woshers
(see Note 1)

See Note 4 ~
1

-I-

0
Anchor poy I i mi t

(see Note 2)

Anchor Post Assembly


(See Note 3)

BEAM GUARDRAIL ANCHOR


TYPE 7

TYPE 7 ANCHOR

STANDARD PLAN C-6f


APPROVED FOR PUBLICATION

Donald K. Nelson

-----------------------------

STATE DESIGN ENGINEER

07125197
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

....1
....1

0
0

::::i

z
c:::
w

27 1/2"

- )J

NOTES

~I-~--------~---------~

11..

cb

2 1/4,::1
133/8"

PLAN

8 1/2"

3/4" X 2 1/2"
POST BOLT SLOT
3/8" HOLE
(OPTIONAL)

L
4 1/4"

I
I

2.

Attach guardrail to bridge rail or concrete barrier with 7/8" diameter


bolts (five minimum) Standard Spec. 9-06.5(4), with thin slab
ferrule inserts or resin bonded anchors. See the Contract Plans.

3.

A single piece having similar dimensional shape to Design G


and mating with the W-beam guardrail is an alternate.

4.

In cases where Design "F" end section is lapped on the outside


of the guardrail, a galvanized 1" ID, 2" OD, 0.134" thick,
narrow Type A Plain Washer or a anchor rail washer shall be
placed under the splice bolt heads.

Co
.....

N
.....

l
I

End Section Design G shall be used except where noted on the


plans or contract.

cb

PLAN

SPLICE BOLT
SLOT (TYP.)
29/32" X 1 1/8"

1.

SPLICE BOLT
SLOT (TYP.)
29/32" X 1 1/8"

I
I

7~~-~

ELEVATION

4 1/4"

DESIGN C

ELEVATION

DESIGN D
END SECTION

DESIGN A

PLAN
SPLICE BOLT
SLOT (TYP.)
29/32" X 1 1/8"

0
30"

, 318" ] _

30"

1 :. 112"
IC:S c:6

. :.

11
1,. 4 _.!,. 4".,

7 1/4"

PLAN

0
0

~ -~. ~ ~~EB~NT~FOR
DESIGN G

3"

SPLICE BOLT
SLOT (TYP.)
29/32" X 1 1/8"

ELEVATION

DESIGN D

SPLICE BOLT
SLOT (TYP.)
29/32" X 1 1/8"

1" HOLES (TYP.)


(SEE NOTE 2)

ELEVATION

(SEE NOTE 3)

3 1/2"
3 1/2"

N
.....

DESIGN G

~~===+~~======~~~~
~

~
.....
~

BEAM GUARDRAIL
END SECTIONS
STANDARD PLAN C-7
SHEET 1 OF 1 SHEET

ELEVATION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

DESIGN F
(SEE NOTE 4)

-~----~S~~=TE~D=Es=IG~NE~N~GIN~E=ER~----

06-16-11
DATE

" ' Washington State Department of Transportation

NOTES
29/32" X 1 1/8"
SLOTS (TYP)

....1
....1

29/32" X 1 1/8"
SLOTS (TYP)

0
0

::::i

1. Attach guardrail to bridge rail or concrete barrier with 7/8"


diameter bolts (five minimum) Standard Spec. 9-06.5(4),
with thin slab ferrule inserts or resin bonded anchors.
See the Contract Plans.

N
N

0::

8 1/2"

L1..

I
.. I

2. In cases where Design F End Section is lapped on the


outside of the guardrail, a galvanized 1" ID, 2" OD,
0.134" thick, narrow Type A Plain Washer or an anchor
rail washer will be placed under the splice bolt heads.

=
b

29/32" X 1 1/8"
SLOTS (TYP)

29/32" X 1 1/8"
SLOTS (TYP)

8 1/2"
25" MIN

..

DESIGN F
(THRIE BEAM)
END SECTION

8 1/2" ..1I

DESIGN C (THRIE BEAM)


DESIGN D (THRIE BEAM)

29/32" X 1 1/8"
SLOTS (TYP)

DESIGN D
(THRIE BEAM) END SECTION

2'- 6"
29/32" X 1 1/8"
SLOTS (TYP)

DESIGN G (THRIE

______:r-

B~ ~:.":r"J" ~ c:p

25" BEND FOR USE WITH

-~-

!e
('I')

2"

4"
1

'

. . . .

4"

c:pl~'
8 1/2"

3"

7 1/4"

1 . . . .

'

'

=
THRIE BEAM
END SECTIONS

Co
~

(;)

/
3/4" HOLES (FOR DESIGN G _ /
END SECTION ONLY)
SEE NOTE 1

<0

~
N

29/32" X 1 1/8"
SLOTS (TYP)

3/4" X 2 1/2"
SLOTS (TYP)

DESIGN G (THRIE BEAM)

STANDARD PLAN C-7a


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

DESIGN F (THRIE BEAM)

Pasco Bakotich Ill


-~----~S~~=TE~D=Es=IG~NE=N=GIN=E=ER~----

06-16-11
DATE

" ' Washington State Department of Transportation

3' - 8" (TYP.)

CD #5

WIRE ROPE LOOP (TYP.)

NOTES

WIRE ROPE LOOP LENGTH

1. Wire rope loops shall be 3' - 8" long, except for the top loop of the Barrier Terminal, which
shall be 2' - 0" long.

.... L.. .

2.

Except for the locations of the wire rope loops, the dimensions shown in END VIEW "A"
are typical for both ends of a Barrier Section or opposing ends of Barrier Terminals.

3.

Connecting and Drift Pin head designs vary among different manufacturers. Pin designs
that are shaped differently than those shown in the detail are acceptable, if the bearing
surface is within the minimum and maximum widths specified.

..1..

\----------------------------------

4. The vertical spacing of the Wire Rope Loops in a Barrier Terminal is determined by the
end of the Barrier Segment to which it is being connected. See BARRIER CONNECTION
DETAIL (Sheet 2).

TOP VIEW

1/4" DRAFT
WIRE ROPE LOOP (TYP.)

1 1/2"

,~-------------------------------------------------1------------------------~)

=~=~~============================

============================~=~=

I
I
I

CONNECTING PIN

WIRE ROPE LOOP

~---------!_l_~-------------------------------------------------4.-----------------------------~
I I
I 6"'!
1 1/2" (TYP.) -----! 12 f"2'\ # 5
~ '-....____
~
:
10'- 0" OR 12'- 6"
"61
TYP.:
PIN

SIDE VIEW

PIN

2" R.- BEVEL OR


ROUND EDGES
3/4" MAX. (TYP.)

BARRIER SECTION
DETAIL

1 1/2" R.

----1

7/8" R.

3/4" CHAMFER
(TYP.)

---L!

9"

~
.....

.
BARRIER
SECTION

...,

LO

BARRIER
TERMINAL

CD #5

@#5

BARRIER
SECTION

BARRIER
TERMINAL

@#5

@#5

(TYP.)

(TYP.)

...,
7"

1/2" CHAMFER
(TYP.)

CONCRETE BARRIER
TYPE2
SEE NOTE 2

ENDVIEW

I.

..

2'- 0"

SECTION

..

STANDARD PLAN C-8

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BARRIER SECTION

BARRIER TERMINAL

ISOMETRIC VIEWS

.....

fll

STATE DESIGN ENGINEER

02-10-09
DATE

Washington State Department of Transportation

WIRE ROPE LOOPS

SEE NOTE 1

HOLE FOR
DRIFT PIN

5/8" WIRE ROPE

WIRE SEIZING - SHALL BE EIGHT WRAPS


OF 16 GAGE WIRE WITH THE ENDS TWISTED
TOGETHER, OR EQUIVALENT FASTENING.

1 3/4" I.D. LOOP

1'- 0"

WIRE ROPE LOOP DETAIL

2'- 3"

3'- 0"

PIN~

TOP VIEW

2" MIN.
2112" MAX.

2" MIN.

I"

"I

~l
~:1_1_~_0_"~~---------------6_'-_0_"
I

2112" MAX

______________

WIRE ROPE LOOPS - SEE NOTE 1

1'- 6"
PLATE WASHER
1/8" THICK

z
ii:

(!)Z

z ii:
i= 1()u...
~ 02
z Cl

-~...,...:;::-,........... -

oo:::

--

I
I

I
I

iio

-----

N'

..

...

....:""'_------ ~ ~---------- """":',:""""':..:.:._--- --:-......... ,;,.;._-------

()0
0::: u...

' '

o&>
u...

_.,.+---;r--'

''

C')

Co

2" R.- BEVEL


OR ROUND EDGES
3/4" MAX. (TYP.)

SIDE VIEW

SIDE VIEW
1" DIAM. PIN WITH
ROUNDED BOTTOM EDGES

SEE NOTE 4

SEE NOTE 3

BARRIER TERMINAL

CONNECTING PINS
AND DRIFT PINS

BARRIER SECTION
REINFORCING STEEL BENDING DIAGRAM

BARRIER TERMINAL
REINFORCING STEEL BENDING DIAGRAM
(

-c-1
......
'

9'- 4 3/4" FOR 10'- 0" LONG BARRIER SECTION


11'- 10 3/4" FOR 12'- 6" LONG BARRIER SECTION

II

CD #5

----

CONCRETE BARRIER
TYPE2

@#5

--

[r

STANDARD PLAN C-8

9'- 4 3/4" FOR 10'- 0" LONG BARRIER SECTION


11'- 10 3/4" FOR 12'- 6" LONG BARRIER SECTION

~~

l~

@#5

1' - 7"

2' - 3"

2' - 10"

1
1
1
1
[rr------~--~_ I it
@#5

BARRIER CONNECTION DETAIL

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

02-10-09
DATE

Washington State Department of Transportation

NOTE
~W i re

iA/;

r-

@-

--.

s"

~-

# 5 Bor s

/,

~
B or B

Cleoronce ___/9I

1/s '~~

s"

3'-

~~~

!II~

2"

3'-

.::;.r .;r-

--~---

For deto i Is on wi re rope loop, connect i ng pin ond


end notches see Stondord Pion "concrete Sorrier
Type 2,"

s"

3'-

.....

rope loop ITYP)

Foce of concrete ot

---.

barrier

~of

'~!
I

10'- o" or 12'- 5"

l.A

lk
Pin

:~

Pin

--1---- - - - - - 1

---- ---- ----

II

~------

--

INTERMEDIATE PLAN

1 o'

- o"

TRANSITION PLAN
4=_

Pin

One 1t 5 Bor
IBor 8)
Cleoronce

'

Two # 5 Bors IBor 8)


3"----

%" Chamfer

'

1
//'

C I eoc once

Two # 5
IBor

L i ft i ng notches

2" Cleoronce

ITYP)

112!1 _ _

Lift i ng notches

Chamfer
4112''

Bevel or round edges


I%" MAX)

Bevel or round
edges I 14 " MAX)

Cleoronce
10'- o" or 12'- 5"

10'~

Pin

INTERMEDIATE ELEVATION

o"

TRANSITION ELEVATION

Pin

5"

to 18"

Pin

CONCRETE BARRIER TYPE 4


AND TRANSITION SECTION

Vor i es
-

q;_

4=_

Pin

4 /z"

Cleoronce

g"

---~:-:__:-_:-_::-_-"!

: 5//

2!!

1'-'-~~~,

'

'

~---,1

'
'
'
'

Droft

"

Bridge
Pier

~~~L------~-~

.r

'
'
'

10" R
N
N

4112''

Cleoronce
~~.

STANDARD PLAN C-Ba


APPROVED FOR PUBLICATION

_ _D_o_n_a_ld_K_.N_e_l_so_n___ 07125197
STATE DESIGN ENGINEER

SECTION A-A

TYPE 4

SECTION B-B

TRANSITION END VIEW

TRANSITION SECTION

ill

DATE

WASHINGTON STATE DEPARTMENT DF TRANSPORTATION


OLYMPIA, WASHINGTON

NOTES
1. This plan shall be used for 40' and 50' Light Standards with 16' max. length double mast arms.
21' - 6"
10'- 0"

9"

2. See Standard Plan C-8 for details on barrier ends, Wire Rope Loops, and Connecting Pins.

9"

10'- 0"

3. Grounding Conductor shall be non-insulated #4 AWG stranded copper, provide 3' - 0" min.
slack. Clamp steel reinforcing bar with connnector suitable for use embedded in concrete.

4. See the Contract Plans for conduit placement.

1/4" DRAFT
I-- ALL CORNERS

~c--c-

m~--~

_ _ _ __l_ _ _ _ _ _ _ _

I
I

I
3/4" CHAMFER

SEE DETAIL "A" FOR


CONDUIT AND ANCHOR
BOLT PLACEMENT

I
I

_V

'---

-~ ~==~~~~~~~~==~~~~~~~~==~~~~~~ - -

<o
'

-l<"l

--- --!--- -- -~~~~~~==~~~~~=t===~~~~~~~==~I~


~ ~ ~ ~
:

~!:I

/ /

-'---

9"

GROUNDING CONDUCTOR - ROUTE TO


GROUNDING STUD (SEE NOTE 3)

--

I
I
I

b.

3'- 6"
2'- 0"

0"1

:I:I

5. Concrete shall be Class 4000.

1/2" CHAJF ER
(TYP.)

b.

I
I
I

a.

STEEL LIGHT STANDARD


- SEE STD. PLAN J-28.60

ANCHOR PLATE (TYP.)


- SEE DETAIL

WIRE ROPE
LOOP (TYP.)

1/2" DRAIN HOLE


ANCHOR BOLT (TYP.)
- SEE DETAIL

iii

II

.....
.....

SEE NOTE 4

jJ
9'- 0"

PLAN

21'- 6"

@
@

#4 - 6 SPACES
1'- 0"

= 6'- 0"

#4- 17 SPACES

@ 6"

= 8'- 6"

2'- 0"

#4 - 6 SPACES
1'- 0"

= 6'- 0"

SEE NOTE 4
7"
SEE NOTE 3

SECTION

10" R.

Co

'

TOP OF
RDWY.

CONSTRUCTION JOINT
WITH ROUGHENED
SURFACE

5'- 0"

#4 - FIELD BEND

'

PAVEMENT

BASE COURSE

SPACING FORG) #4

"

1'- 0"

5 SPACES @
6" = 2' - 6"

(D

1'- 0"

5 SPACES @
6"
2' - 6"

#4 - 8 SPACES @

1'- 0"

1'- 0"

END

= 8'- 0"

CONCRETE BARRIER
LIGHT STANDARD SECTION

9'- 0"

ELEVATION

STANDARD PLAN C-Bb


SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

HEAVY HEX NUTS


AND WASHERS

POLE BASE PLATE SEE STD. PLAN J-28.60

i~I

'

-~

-~=

HEAVY HEX NUTS


AND WASHERS

POLE BASE PLATE SEE STD. PLAN J-28.60

TOP OF

TOP OF

BARRIER

BARRIER

'

------0---0-

-_ =-=---=-------= ~ ----4T--I-_ -'

M
C\1

I
I
I
I

'

1-

1-

rn~

rn~

1" DIAM. BOLT


- ASTM A 449

.o
LlJ

C\1

1" DIAM.
THREADED ROD
- ASTM A 449

!Il

:::!:
LlJ

.o

C\1

LlJ
!Il

:::!:
LlJ

ANCHOR BOLT (TYP.)


- SEE DETAIL
ANCHOR PLATE (TYP.)
- SEE DETAILS

HEAVY HEX NUT


AND WASHER (TYP.)

ANCHOR PLATE (TYP.)


- SEE DETAILS

HEADED
BOLT
2" CONDUIT
- SEE NOTE 4

HEAVY HEX NUT


AND WASHER (TYP.)
THREADED
ROD

ANCHOR BOLT DETAIL


13.89" DIAM.
BOLT CIRCLE

DETAIL "A"

12" DIAM.

16" DIAM.

GALVANIZE EXPOSED ANCHOR ROD END 1'- 0" MIN.

1" DIAM.
HOLE (TYP.)

1/2" PLATE
ANCHOR PLATE

BAR LIST

BENDING DIAGRAM

MARK

LOCATION

CD

FOOTING - DOWEL

28

4'- 3"

FOOTING

18

4'- 8"

CD

FOOTING

G)

BARRIER

21'- 0"

BARRIER

21'- 0"

30

5'- 3" TO
6'- 9"

QTY.

SIZE

LENGTH

8'- 8"
#4

BARRIER

f/

10~

<'

- CD

~~

(ALL DIMENSIONS ARE OUT TO OUT)


3" TO

9'- 9"

fT-~
I
(FIELD BEND)

G)

1\1

CONCRETE BARRIER
LIGHT STANDARD SECTION
STANDARD PLAN C-Bb
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

NOTES
1. The intended use of this plan is for the permanent anchoring of Precast Concrete
Barrier Type 2 (see Standard Plan C-8) on hot mix asphalt pavement.
2.

Remove the Type 3 Anchors by first driving the steel pins down through the barrier
further into the pavement to allow lifting the barrier without interference, then remove the pins from the pavement.

3. After removing the Type 3 Anchors, clean the pin holes and fill them with sealant
according to Standard Specification 9-04.2.

TRAFFIC
SIDE

SHOULDER
WIDENING

TRAFFIC
SIDE

TRAFFIC
SIDE
1'- 0"

2'- 0"

PRECAST CONC. BARRIER TYPE 2

PRECAST CONC. BARRIER TYPE 2


2" DIAM. PINNING
HOLE (TYP.)

HMA

PINNING HOLE (TYP.) - ONLY REQUIRED


ON TRAFFIC SIDE(S) OF BARRIER

HMA

2'- 0"

PLAN VIEW

TYPE 3 ANCHOR
PIN LOCATIONS

lWO PINS REQUIRED


ON THE TRAFFIC SIDE
- lWO PINS TOTAL,
PER BARRIER SECTION

1" DIAM. )( 30"


GALVANIZED STEEL PIN
(TYP.)

lWO PINS REQUIRED


PER TRAFFIC SIDE
-FOUR PINS TOTAL,
PER BARRIER SECTION

SECTION VIEWS

TYPE 3 ANCHOR
PIN LOCATIONS

PRECAST CONC. BARRIER


ANCHOR - TYPE 3
(PERMANENT}
STANDARD PLAN C-8e
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

0212007
DATE

REMOVED TEMPORARY ANCHORS


REVISION

MAS
BY

.....

Ken L. Smith
STATE DESIGN ENGINEER

fJ'I Washington

02-21-07
DATE

State Department of Transportation

PIN

@#5

ct

3"

WIRE ROPE LOOP (TYP.)


SEE STD. PLAN C-8

1 1/2" R.

1"718"

3'- 8" (TYP.)


WIRE ROPE LOOP LENGTH

CROWN

PIN
1 1/2" R.

112" CHAMFER

112" CHAMFER

ct
!

@#5

3"

~18" R.

3/4" CHAMFER
(TYP.)

~~=+==+-====A

CD #5
WIRE ROPE
LOOP (TYP.)
to

~
.....

@#5

2" CLR.

WIRE ROPE LOOP (TYP.)


SEE STD. PLAN C-8

@#5

(V)

TOP VIEW

....
ci
....1

CD #5

@#5

(.)

C1

2" CLR.

____!
I
I
I

---------,
I

in

----------------------------------------r---------------------I

3"

PIN

2" CLR.

1'- 0"

10 1/4"

(TYP.)

ct

PIN

3"

@#5

ct

CONCRETE BARRIER TYPE 2 (NJ-SHAPE)

BRIDGE F-SHAPE TRAFFIC BARRIER

END VIEW

END VIEW
I

I I

2" R.- BEVEL OR


)/ 6" I
ROUND EDGES __/ ~
3/4" MAX. (TYP.)
i TYP.

ct PIN

Ql # 5

10'- 0" OR 12'- 6"

#5

1 1/2" (TYP.)

--1

~--~

1--1

-1~---------------------------------------------------------------------------------------1

BARRIER FACE
OF CONCRETE

PIN

ct

TRAFFIC-SIDE VIEW

!........_

PIN

ct
!........_

TRANSITION SECTION

F-SHAPE CONCRETE
TRAFFIC BARRIER
ON BRIDGE

CONNECTING PINSEE STD. PLAN C-8

ct PIN

2'

1 3/4" I.D. LOOP

TRANSITION SECTION
- MIRROR IMAGE OF PLAN

9"

- 0"

2'- 0"

6"

5 1/4"

9"

48
1~

48
1 c::::::::====--

FLAT

11 1/2"

TRANSITION SECTION
-AS SHOWN IN PLAN

7 1/4"
CROWN

48
=-:::::::::J 1

WIRE ROPE LOOP SEE STD. PLAN C-8

'I
CROWN

TYPICAL - BOTH ENDS

DETAIL

....'

7"

4 7/8"

to

'

REINFORCING STEEL BENDING DIAGRAM


I

CONCRETE
BARRIER TYPE 2

10" R.

9'- 4 3/4" FOR 10'- 0" LONG TRANSITION

11' - 10 3/4" FOR 12' -~ ~ LONG TRANSITION

I~

ll

CD #5
@#5

@#5

@#5

10"

11 3/4"

NOTE

f-

Z-1'

1-?

1'- 6 1/2"
1'-4"

CONCRETE BARRIER TYPE 2 (NJ-SHAPE)


@#5

ISOMETRIC VIEW

10" R.

b
.....

SECTION

(SHOWN AT LIMIT OF TRANSITION)

BRIDGE F-SHAPE TRAFFIC BARRIER

SECTION

(SHOWN AT LIMIT OF TRANSITION)

The vertical locations of the Wire Rope Loops at one


end compose a set that shall not vary; however, which
set is applied to an end is determined by the end to
which it is being connected. A set with loops 1' - 5"
apart connects to a set with loops 1' - 8" apart. See
Standard Plan C-8, BARRIER CONNECTION DETAIL.

CONCRETE BARRIER
TRANSITION
TYPE 2 TO BRIDGE F-SHAPE
STANDARD PLAN C-8f
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

06-30-04
DATE

State Department of Transportation

NOTES
10"

1"

2 1/4"

5"

1. Length of W8 x 35 and W6 x 9 shall be determined by measurement from top of


ground to top of grout pad. This distance shall be verified by the Contractor.

1 3/4"

2. Attach Guardrail Post to Box Culvert with 3/4" diameter high strength bolts with
resin bonded anchors.

WOOD BLOCK FOR STEEL POSTS


-SEE STANDARD PLAN C-1b

TRAFFIC SIDE

1" X 1 1/2" SLOTTED


HOLE (TYP.)

3.

Drill 1 1/4" diameter hole in concrete slab for 7/8" diameter high strength bolt.
Length of bolt is determined by top slab of Box Culvert thickness which shall be
verified by the Contractor.

4.

For details of post attachment to Double Box Culvert, see Standard Plan C-2i.

W6 X 9
STEEL POST

5/8" STEEL PLATE


SEE POST ANCHOR ATTACHMENT
DETAIL FOR CENTER OF
DOUBLE BOX CULVERT

POST BASE PLATE DETAIL

GROUND LINE

W6 x 9 STEEL POST
-SEE NOTE 1

EXISTING BOX CULVERT

TRAFFIC SIDE

HIGH STRENGTH BOLTS


- FOUR REQUIRED
(SEE NOTE 3)

POST BASE PLATE


EXISTING
BOX CULVERT

3/4" GROUT PAD

BOX CULVERT GUARDRAIL STEEL POST TYPE 2


(0" TO 6" GROUND COVER)

8 1/2"
1 1/2"

5 1/2"

1 1/2"

POST BEARING PLATE

1" DIAMETER HOLE


(TYP.)

-$----'

DETAIL

POST BASE ATTACHMENT


5/8" STEEL PLATE

W6 X 9
-SEE NOTE 1

-~---~

POST BASE PLATE


3/4" GROUT PAD

POST BEARING PLATE DETAIL

~[=
~

=
co

f----------..
DOUBLE BOX
CULVERT

SEE NOTE 2

BOX CULVERT GUARDRAIL


STEEL POST
STANDARD PLAN C-10
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

POST ANCHOR ATTACHMENT DETAIL


(SEE NOTE 4)

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-10
DATE

Washington State Department of Transportation

8 1/4"
5"

1 5/8"

WOOD BLOCK FOR STEEL POSTS


-SEE STANDARD PLAN C-1b

1 5/8"

W8 x 35 STEEL POST
-SEE NOTE 1
TRAFFIC SIDE

TRAFFIC SIDE

:.-$-- ~35.:
-----@-:

~
~

I
I

-~~----

Co

---

~-cr--

I
I

'

--~/
'

---

- :
I
I

HIGH STRENGTH BOLTS


- FOUR REQUIRED
(SEE NOTE 3)

W6 X 9 X 27.5"
STEEL POST

1" DIAMETER HOLE (TYP.) IN COVER


PLATE FOR 3/4" x 2" LONG BOLT
WITH HEX NUT AND WASHER

BASE PLATE

EXISTING
BOX CULVERT

3/4" GROUT PAD

TRAFFIC SIDE
GROUND LINE

5/8" STEEL PLATE

1/4

BEARING PLATE

COVER PLATE DETAIL

2"

5 1/2"

-e-

DETAIL

W8 X 35
STEEL POST

15"
5 1/2"

POST ATTACHMENT

2"

1" DIAMETER HOLE


(TYP.)

---+---W8

35

SEE ANCHOR ATTACHMENT


DETAIL FOR CENTER OF
DOUBLE BOX CULVERT

W6 X 9 X 27.5"
STEEL POST

TRAFFIC SIDE

--t--

+-~~~~+

'

-~-

POST BASE PLATE


- SEE DETAIL SHEET 1

EXISTING BOX
CULVERT

3/4" x 2" LONG BOLT WITH


HEX NUT AND WASHER
(TYP.)

GROUND LINE

1" STEEL PLATE

COVER PLATE
TACK WELD NUT
TO PLATE (TYP.)

3 7/16"

W8 x 35 STEEL POST
-SEE NOTE 1

BOX CULVERT GUARDRAIL STEEL POST TYPE 1

1/4

(6" TO 36" GROUND COVER)

BASE PLATE DETAIL


W8 X 35
-SEE NOTE 1

15"

. 2"

..

BASE PLATE

11"

3/4" GROUT PAD

BASE ATTACHMENT

1" DIAMETER HOLE


(TYP.)

-4-----------

;[~
~

=
co

~-------.,.

DOUBLE BOX
CULVERT

5/8" STEEL PLATE


b

DETAIL

Co

SEE NOTE 2

STANDARD PLAN C-10

'

-~-----------~

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


06-03-10
----------------------STATE DESIGN ENGINEER
DATE
ANCHOR ATTACHMENT DETAIL

BEARING PLATE DETAIL

BOX CULVERT GUARDRAIL


STEEL POST

(SEE NOTE 4)

.....

fll

Washington State Department of Transportation

SHOULDER

SHOULDER

4.0' MIN.

NOTE

3.0' MIN.

1. For W-Beam Type 31 shoulder application,


see Standard Plan C-28.40.

HINGE-POINT

MATCH
SHOULDER
SLOPE

PAVEMENT

HINGE-POINT

PAVEMENT
2H: 1V OR
FLATTER SLOPE

1.5H: 1V OR
FLATTER SLOPE

TYPE 3 ANCHORS
- SEE STANDARD PLAN C-Se

PRECAST CONC. BARRIER TYPE 2

ANCHORED PRECAST
CONC. BARRIER TYPE 2

FACE OF BARRIER

SHOULDER

SHOULDER

4.0' MIN.

4.0' MIN.

HINGE-POINT

HINGE-POINT

HINGE-POINT

1.5H: 1V OR
FLATTER SLOPE

2H: 1V OR
FLATTER SLOPE

1.5H: 1V OR
FLATTER SLOPE
II
II
II
II
II
II

II

__u,yL

SINGLE SLOPE CONC. BARRIER


CAST-IN-PLACE

SINGLE SLOPE CONC. BARRIER


PRECAST

FACE OF BARRIER
SHOULDER

CABLE BARRIER

FACE OF BARRIER
2.0' MIN.

SHOULDER

3.5' MIN.

HINGE-POINT

HINGE-POINT

STEEPER THAN 2H : 1V
BUT NOT STEEPER
THAN 1H: 1V

2H: 1VOR
FLATTER SLOPE
''
'

TRAFFIC BARRIER SHOULDER


WIDENING - FOR SHOULDERS
8.0' AND WIDER
STANDARD PLAN C-16a
SHEET 1 OF 1 SHEET

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BEAM GUARDRAIL TYPE 1

BEAM GUARDRAIL TYPE 1 ON STEEP SLOPES

(SEE NOTE 1)

(SEE NOTE 1)

.....

fll

STATE DESIGN ENGINEER

06-03-10
DATE

Washington State Department of Transportation

SHOULDER

2.0'

SHOULDER

4.0' MIN.

2.0'

3.0' MIN.

SEE NOTES
1&2

SEE NOTES
1&2

NOTES
1. An additional width for shy distance is required
when the existing roadway is to be widened.

HINGE-POINT

2. The additional width for shy distance may be


less than 2.0' when it, combined with the
existing shoulder width, totals 8.0' or more.

HINGE-POINT
PAVEMENT

PAVEMENT
2H: 1V OR
FLATIER SLOPE

1.5H: 1V OR
FLATTER SLOPE

3.

For W-Beam Type 31 shoulder application,


see Standard Plan C-28.40.

TYPE 3 ANCHORS
- SEE STANDARD PLAN C-Be

PRECAST CONC. BARRIER TYPE 2

ANCHORED PRECAST
CONC. BARRIER TYPE 2

FACE OF BARRIER
SHOULDER

2.0'

SHOULDER

4.0' MIN.

2.0'

4.0' MIN.
SHOULDER

SEE NOTES
1&2

SEE NOTES
1&2

2.0'

1.5' MIN.

SEE NOTES
1&2

HINGE-POINT

HINGE-POINT

1.5H: 1V OR
FLATIER SLOPE

1.5H: 1V OR
FLATIER SLOPE

HINGE-POINT

MATCH
PAVED
SHOULDER
SLOPE

2H: 1VOR
FLATTER
SLOPE

,_

II
II

II
II

II

II

_lrJ-

SINGLE SLOPE CONC. BARRIER


CAST-IN-PLACE

SHOULDER

2.0'

SINGLE SLOPE CONC. BARRIER


PRECAST

2.0' MIN.

SHOULDER

2.0'

CABLE BARRIER

3.5' MIN.

SEE NOTES
1&2

SEE NOTES
1&2
EXTEND PAVED SHOULDER
TO FACE OF GUARDRAIL
UNLESS CURB IS REQUIRED
-SEE STANDARD PLAN F-10.40

HINGE-POINT

''
'

EXTEND PAVED SHOULDER


TO FACE OF GUARDRAIL
UNLESS CURB IS REQUIRED
-SEE STANDARD PLAN F-10.40

HINGE-POINT

2H: 1VOR
FLATTER
SLOPE

''
'

STEEPER THAN 2H : 1V
BUT NOT STEEPER
THAN 1H: 1V

TRAFFIC BARRIER SHOULDER


WIDENING - FOR SHOULDERS
LESS THAN 8.0 WIDE
STANDARD PLAN C-16b
SHEET 1 OF 1 SHEET

BEAM GUARDRAIL TYPE 1

BEAM GUARDRAIL TYPE 1 ON STEEP SLOPES

{SEE NOTE 3)

{SEE NOTE 3)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-10
DATE

Washington State Department of Transportation

FACE OF
BARRIER

BEAM GUARDRAIL TYPE 31

6'- 3"

3' - 1 1/2"

NOTES

6'- 3"

6'- 3"

W- SEE TABLE

1. Refer to Standard Plan C-1 and C-1 b for additional


details not shown on this plan.

W6 x 9 STEEL POST SEE NOTE 1

o,

o,

MID SPAN_/
SPLICE

2. Extend shoulder pavement to provide a base for the


extruded curb. See Contract Plans for exceptions to
distances shown.

GROUND LINE

3.
F-.

'

TYPICAL ELEVATION
13'- 6 1/2"

GROUND LINE

I
----------~~--------~--~~--~i
,,

SLOPESEE TABLE

(TYP.)I

0
0

z
c::

(TYP.)

( 6' - 0" LONG POSTS)


2" (TYP.).I
-.

L1..

AB~UT <t

i:_.

_/

2H : 1V OR FLATTER

2.5' MIN.

STEEPER THAN 2H : 1V
BUT NOT
STEEPER THAN 1H : 1V

4.0' MIN.

TYPICAL RAIL ELEMENT

1 3/16"

1/4" DIAM. HOLE FOR


ANTI-ROTATION 16d NAIL
(TYP.)

W6 x 9 STEEL POST
- SEE NOTE 1

II

1" (TYP.)

ANTI-ROTATION
NAIL 16d (TYP.) \

11~

iil__l_

\
\

6' LONG STEEL POST


(TYP.) - SEE NOTE 1

I
~
<

5/8" RECESSED
HEX NUT (TYP.)
6 x 12 BLOCKOUT (TYP.) SEE NOTE 3

3/4" DIAM. HOLE THROUGH BLOCK


FOR STEEL POST ATTACHMENT

PLAN VIEW

WOODBLOCK

3/4" DIAM. HOLE FOR BUTTON


HEAD BOLT (TYP.)

STEEL POST

FACE OF
BARRIER

12 BLOCKOUTSEE NOTE 4

SLOPE

....:.....::.:..:..::....l,l~

5/8" x 14" BUTTON HEAD BOLT


WITH 7/32 " OVAL GRIP AND
RECESSED HEX NUT (TYP.)

SLOPE\EMBANKMENTTABLE

3/4" X 2 1/2"
SLOT (TYP.)

W6

1'- Q 1/4'

'

SHOULDER

4. Wood blocks are shown. Blocks of an approved


alternative material may be used. See Standard
Specification 9-16.3(2).

SYMMETRICAL

6 X 12 BLOCKOUT
- SEE NOTE 4

RAIL ELEMENT

3' - 1 1/2"

i:ii:iiiiiiii,iiiiiiiiiiiiiiiiiiiiiiiiii~o~]

TYPICAL SECTION -WITHOUT CURB

::::i

iljl ~
j

....1
....1

6'- 3"

3' - 1 1/2"

HINGEPOINT

Use a single block or combination of blocks (no more


than 2) to achieve the actual 12" offset. See
Standard Specification 9-16.3(2). Wood blocks
shall be secured to the steel posts with anti-rotation
nails as detailed. If combination blocks are used, the
adjacent blocks shall be toe nailed with two 16d
galvanized nails to prevent block rotation.

SEE NOTE 3

W- SEE TABLE
W6 x 9 STEEL POST SEE NOTE 1

PERMISSIBLE CURB
PLACEMENT AREA SEE NOTE 2

SEE NOTE 3

W6 x 9 STEEL POST (TYP.)


GROUND LINE
RAIL ELEMENT
(TYP.)

5/8" x 14" BUTTON HEAD BOLT


WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT (TYP.)

BEAM GUARDRAIL TYPE 31


STANDARD PLAN C-20.10-01

SLOPESEE TABLE

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC VIEW
ELEVATION VIEW

TYPICAL SECTION - WITH CURB


( 6' - 0" LONG POSTS)

5/8" x 1 1/4" BUTTON HEAD BOLT


WITH 7/32" OVAL GRIP (TYP.)
AND RECESSED HEX NUTS 8 REQUIRED PER SPLICE

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

NOTES

....1
....1

0
0

BEAM GUARDRAIL
ANCHOR TYPE 10
-PAY LIMIT
SEE NOTE 1 & 4

::::i

0:::

11..

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT

BEAM GUARDRAIL
TYPE 31 - PAY LIMIT

SEE STANDARD PLAN C-22.40

SEE NOTE

VARIES (SEE CONTRACT)


ONE-WAY TRAFFIC

31

1.

For component details, see Standard Plan C-23.60.

2.

For terminal type and details, see Contract Plans and applicable drawings.

3.

The slope from the edge of the shoulder into the face of the guardrail cannot
exceed 10H : 1V when the face of the guardrail is less than 12'- 0" from the
edge of the shoulder.

4.

For one-way traffic and where a crashworthy terminal is not required, use
the Beam Guardrail Anchor Type 10, see Standard Plan C-23.60.

5. Where a crashworthy terminal is required use a Beam Guardrail Type 31


Non-Flared Terminal, see Standard Plan C-22.40.

EDGE OF SHOULDER

CASE 1-31

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE STANDARD PLAN C-22.40

BEAM GUARDRAIL
TYPE 31 - PAY LIMIT

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE STANDARD PLAN C-22.40

SEE NOTE 5

SEE NOTE

VARIES (SEE CONTRACT)

31

EDGE OF SHOULDER

TWO-WAY TRAFFIC

CASE 2-31

BEAM GUARDRAIL
ANCHOR TYPE 10
PAY LIMIT- SEE NOTE 1

BEAM GUARDRAIL
TYPE 31 - PAY LIMIT

VARIES (SEE CONTRACT)

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE STANDARD PLAN C-22.40

ONE OR TWO WAY TRAFFIC

CASE 3-31

EDGE OF SHOULDER

BEAM GUARDRAIL TYPE 31


PLACEMENT
(CASES 1-31, 2-31, & 3-31)
STANDARD PLAN C-20.14-02
SHEET 1 OF 1 SHEET

RAIL~OAD

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

BEAM GUARDRAIL TRANSITION SECTION :

BEAM GUARDRAIL TYPE 31

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL


-PAY LIMIT (SEE NOTE 1}

"
I

BRIDGE

\__ BRIDGE TRAFFIC BARRIER

....1
....1

ONE OR TWO-WAY TRAFFIC

LlJ

c
c

\ _ EDGE OF SHOULDER

::::i

NOTES
1. For details, see Standard Plan C-22.40.

a::

CASE 4-31

LlJ
LL.

2. The slope from the edge of the shoulder into the face of the
guardrail should not be steeper than 10H : 1V when the
guardrail is within 12' - 0" from the edge of the shoulder.

:;..:

!Il

3. See Contract for Beam Guardrail Transition Section type and


Connection to Bridge Traffic Barrier or Concrete Barrier.
See Standard Plan C-24.1 0 for connection details.

BRIDGE

BEAM GUARDRAIL TRANSITION SECTION

BEAM GUARDRAIL TYPE 31

TYPE 31 - PAY LIMIT (SEE NOTE 3)

- PAY LIMIT

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL


- PAY LIMIT (SEE NOTE 1)

\__ BRIDGE TRAFFIC BARRIER


\ _ EDGE OF SHOULDER
ONE OR TWO-WAY TRAFFIC

CASE 5-31

FLARE RATE TABLE


POSTED SPEED
(MPH)

RATE

70

15: 1

60

14: 1

55

12: 1

50

11 : 1

STANDARD PLAN C-20.15-01

45

10: 1

SHEET 1 OF 1 SHEET

40 OR LESS

9: 1

BEAM GUARDRAIL TYPE 31


PLACEMENT
(CASES 4-31 & 5-31)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

NOTES

....1
....1

0
0

1. The slope from the edge of the shoulder into the face of
the guardrail should not exceed 1OH : 1V when the guardrail
is within 12' - 0" from the edge of the shoulder.

::::i

0:::

11..

2. For details, See Standard Plan C-23.60.


3. For details, See Standard Plan C-22.40.
BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT

BEAM GUARDRAIL TYPE 31

BEAM GUARDRAIL TYPE 31

SEE NOTE 3

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL - PAY LIMIT

-PAY LIMIT

(SEE NOTE 3)

---=-_L_-----::.

.FIXED FiTURE

(TYP.)

SEE NOTE 1

EDGE OF SHOULDER

VARIES - SEE CONTRACT

TWO-WAY TRAFFIC

EDGE OF SHOULDER

VARIES - SEE CONTRACT

c ONE-WAY TRAFFIC
OR

CASE 10A- 31

TWO-WAY TRAFFIC

(TRAILING END)

CASE 1OA-31, 1OB-31, OR 1OC-31


(APPROACH END)

BEAM GUARDRAIL ANCHOR TYPE 10 ------.


- PAY LIMIT (SEE NOTE 2)

, BEAM GUARDRAIL TYPE 31


-PAY LIMIT
FIXED FEATURE

EDGE OF SHOULDER

VARIES - SEE CONTRACT

..- ONE-WAY TRAFFIC

CASE 108-31
(TRAILING END)
BEAM GUARDRAIL ANCHOR TYPE 10 ---..._
- PAY LIMIT (SEE NOTE 2)

BEAM GUARDRAIL TYPE 31


-PAY LIMIT

BEAM GUARDRAIL EXTENSION


LENGTH VARIES- SEE CONTRACT

FIXED FEATURE

I1

~ ~0
.

I
I

C<>:!:

, ~

i'""j" ~
I

EDGE OF SHOULDER

~-t

BEAM GUARDRAIL TYPE 31


PLACEMENT (CASES 1 OA-31,
108-31 & 10C-31)
STANDARD PLAN C-20.18-01

VARIES - SEE CONTRACT

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

..- ONE-WAY TRAFFIC

Pasco Bakotich Ill

CASE 10C-31
(TRAILING END)

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


(SEE NOTE 5)

BEAM GUARDRAIL TRANSITION


SECTION TYPE 21
-PAY LIMIT
(SEE NOTE 4)

BEAM GUARDRAIL TYPE 11


-PAY LIMIT

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE NOTE 5

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

1SEE NOTE 1

SEE NOTE
SEE NOTE 2

EDGE OF SHOULDER

VARIES - SEE CONTRACT

SEE NOTE 2

NOTES

TWO-WAY TRAFFIC

MAINTAIN POST SPACING OF 3'- 11/2" MAX.


ADJUST TRANSITION TO NEAREST FIXED FEATURE

__.

__.

1. The slope from the edge of the shoulder into the


face of the guardrail should not exceed 10H : 1V
when the guardrail is within 12' - 0" from the edge
of the shoulder.

CASE 11A-31

11

0
0

::J

2. Attach the standard wood block to the rail using two


5/8" x 4" lag bolts.

0:::

LL.

BEAM GUARDRAIL
ANCHOR TYPE 10
-PAY LIMIT
(SEE NOTE 3)

BEAM GUARDRAIL TYPE


-PAY LIMIT

11

BEAM GUARDRAIL TRANSITION


SECTION TYPE 21
- PAY LIMIT (SEE NOTE 4)

3. Beam Guardrail Anchor Type 10 (W-Beam) or


Type 10 (Thrie Beam) required. For details,
see Standard Plan C-23.60.

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE NOTE 5

4. For details, see Standard Plan C-25.20.

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

5. For details, see Standard Plan C-22.40.


l

SEE NOTE
VARIES - SEE CONTRACT

11

EDGE OF SHOULDER

SEE NOTE 2

c ONE-WAY TRAFFIC

CASE 118-31

BEAM GUARDRAIL
ANCHOR TYPE 10
-PAY LIMIT
SEE NOTE 3

~ ~

BEAM GUARDRAIL
TYPE 31 - PAY LIMIT

LL

f4

I"

0 I

BEAM GUARDRAIL TYPE 11


-PAY LIMIT

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT


SEE NOTE 5
BEAM GUARDRAIL TYPE 31 - PAY LIMIT

i ~L

SEE NOTE 2
REDUCER ELEMENT TYPE C
(TYPE 31) - FOR DETAIL
SEE STD. PLAN C-25.20

BEAM GUARDRAIL TRANSITION


SECTION TYPE 21
- PAY LIMIT (SEE NOTE 4)

SEE NOTE
SEE NOTE 2

VARIES- SEE CONTRACT

c ONE-WAY TRAFFIC

EDGE OF SHOULDER

11

BEAM GUARDRAIL TYPE 31


PLACEMENT (CASES 11 A-31,
118-31 & 11C-31)
STANDARD PLAN C-20.19-01
SHEET 1 OF 1 SHEET

CASE 11C-31

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

712112
DATE

. . . Washington State Department of Transportation

c
c
z

CRT POST- {SEE DETAIL)


{SEE NOTE 2)

CRT POST - {SEE DETAIL)


{SEE NOTE 2)

....1
....1

SPAN = 12'- 6" {OMIT 1 POST)


,_____ _ _ _ _ _ _ SPAN = 18'- 9" {OMIT 2 POSTS) _ _ _ _ _ _ ______,
_ _ _ _ _ _s_P_AN_=_2_5_'- 0" {OMIT 3 POSTS)
1

::::i
0:::

L1..

W6x9 STEEL POST


{TYP.)

~- - - - - - - - - - - - - -

:
I

I
I

I
I

======~======~======~======~==~==========~~==========~==~======~======~======~~====
BURIED
_ _ _ _ _ _ _ _o::_:B~STRUCTION

6'- 3"
{TYP.)

NOTES

~----____l

1. For additional details not shown on this plan,


refer to Standard Plan C-20.1 0.

--.-~----------ONE OR TWO-WAY TRAFFIC

2. CRT post to be wood only.

PLAN VIEW
SINGLE W-BEAM RAIL ELEMENT
BEAM GUARDRAIL TYPE 31 - PAY LIMIT

W6x9 STEEL POST


{TYP.)

''' '''
'' ''
'' ''
'' ''
' '
:_!

,...,

,...,

'' ''
'~===~'
'' ''
'' ''
:_I

GROUND LINE

,...,

'' ''
'~===~'
'' ''
'' ''
:_

'' ''
'~===~'
'' ''
''' '''

----------------------------------------------~

I
I

I
I

OBSTRUCTION

I
I
I

-----------------------------------------------I
CRT POST- {SEE DETAIL)
{SEE NOTE 2)

CRT POST - {SEE DETAIL)


{SEE NOTE 2)

ELEVATION VIEW

0" MIN. OFFSET FROM BACKSIDE OF GUARDRAIL POST ~


AND FACE OF CULVERT HEADWALL PERMITTED

BEAM GUARDRAIL TYPE 31


{BEYOND CULVERT)

BACKSIDE OF CRT POST


FINISHED GRADE
FACE OF
HEADWALL

in
N

WING WALL

..

(BEYO-r~

CULVERT

~~

b
I

Co
FACE OF HEADWALL

CRT POST- {SEE DETAIL)


{SEE NOTE 2)

2 3/8" HOLE

CRT POST - {SEE DETAIL)


{SEE NOTE 2)
6 X 8WOOD
POST

BACKSIDE OF
POST {TYP.)

SECTION

BEAM GUARDRAIL TYPE 31


PLACEMENT 12'- 6" 18'- 9"
OR 25' - 0" SPAN
STANDARD PLAN C-20.40-03

SHEET 1 OF 1 SHEET
I I
I I

::
cuLVERTJ

'7-

L ~,------

SPAN WITH HEADWALL DETAIL

CONTROLLED RELEASING
TERMINAL (CRT) POST DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

. . . Washington State Department of Transportation

TRANSITION PAY LIMIT

en

zw

(SEE NOTE 1)

0::

' ' ' ' ). _____(~:-::1

Ill
....1
....1

iii

NOTES

1. See Contract for transition and connection type.

BRIDGE END _ /

I-

C..

CASE 22C-31

2. For additional installation requirements for Non-Flared Terminal


placement see Standard Plan C-22.40.

(SEE NOTE 4)

3. Guardrail installation shall be Beam Guardrail Type 31 with


standard post and block. See Standard Plan C-20.1 0 for
additional details.

POINT B
NON - FLARED TERMINAL

RADIUS VARIES
(SEE CONTRACT)

PAY LIMIT (SEE NOTE 2)

4. The first letter of case designation indicates the end treatment


on the side road. The second letter indicates the end treatment
on the main road. For instance, a terminal on a side road and a
bridge connection on the main road would be Case 22BC-31.

-~-

CASE 22D-31

SHOULDER BREAK

(SEE NOTE 4)
W6 x 9 STEEL POST (TYP.)

5. The radius dimension shall be etched into the plate as shown


in the example on the Identification Plate Detail. Numerals
shall be 1 1/2" high minimum, and 3/4" wide maximum.
Plate shall be galvanized after etching and the letter shall
remain permanently legible.
6. The guardrail Identification Plate shall be mounted at the
lower splice bolt on the back side of the rail element at the
PC of the guardrail radius.

(X) SPACES AT 6'- 3"


(1 SPACE MIN.)

POINT A
5"
3/4" DIAM. HOLE

....1

<( N

z w
~b

ffi

1/4" STEEL PLATE

I- w
0 w

w~

0::

::s
u.

BEAM GUARDRAIL
ANCHOR TYPE 10
PAY LIMIT

t::

::!:
,::J

I.

z >-

Q<(

z c..

2 3/4"

IDENTIFICATION PLATE DETAIL


(SEE NOTE 5)

CASE 22A-31
(SEE NOTE 4)

CASE 228-31
(SEE NOTE 4)
SPLICE BOLT
SLOT (TYP.)

GUARDRAIL PLACEMENT
STRONG POST - TYPE 31
INTERSECTION DESIGN
STANDARD PLAN C-20.42-03

lo

SHEET 1 OF 1 SHEET

\ _ IDENTIFICATION PLATE
-SEE DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

IDENTIFICATION PLATE MOUNTING DETAIL


(SEE NOTE 6)

.....

STATE DESIGN ENGINEER

0712112
DATE

. . . Washington State Department of Transportation

NOTES
DIRECTION OF TRAVEL

1. Beam Guardrail post spacing shall be 6' - 3" on centers.


6'- 3"

3'- 1 1/2"

6'- 3"

6'- 3"

2. Use a single or combination of blocks to achieve the actual 12"


offset. See Standard Specification 9-16.3(2). Wood blocks shall
be toe-nailed to post (and blocks, if block combinations are used)
with 16d galvanized nails to prevent block rotation.

3'- 1 1/2"

SEE NOTE2

3. Attach blackouts to steel posts using bolt holes on approaching


traffic side of post web.

6 x 14 BLOCKOUT (TYP.)
(SEE NOTE 2)

4. For details not shown, see Standard Plan C-20.10.


5. Wood blocks shown. Blocks of alternate material may be used.
See Standard Specification 9-16.3(2).
MID-SPAN
SPLICE

5/8" DIAM. x 1 1/4" BUTTON HEAD


BOLT WITH 7/32" OVAL GRIP (TYP.)
AND RECESSED HEX NUTS 8 REQUIRED PER SPLICE

PLAN

6'- 3"

3'- 1 1/2"

6'- 3"

16d ANTI- ROTATION


NAIL (TYP.)- SEE NOTE 2

5/8" DIAM. x 14" BUTTON HEAD


BOLT WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT WITH
CUT WASHER (TYP.)

DIRECTION OF TRAVEL

6'- 3"

3'- 1 1/2"

MIDSPAN
SPLICE

5/8" DIAM. x 1 1/4" BUTTON HEAD


BOLT WITH 7/32" OVAL GRIP (TYP.)
AND RECESSED HEX NUTS8 REQUIRED PER SPLICE

GROUND LINE

:I

I
I

i
I

ii

W6x8.5 x 6' - 0" OR


W6x9 x 6'- 0"
LONG STEEL POST
(TYP.)

~
~

J_

1'

:,

ANTI-ROTATION NAIL
DETAIL

iI

i_L

ELEVATION
3/4" DIAM. HOLE FOR BUTTON
HEAD BOLT (TYP.)SEE DETAIL AT RIGHT
16d ANTI-ROTATION
NAIL (TYP.)

W-BEAM GUARDRAIL (TYP.)


FACE OF
BARRIER

STEEL POST
6

14 BLOCKOUT (TYP.)
-SEE NOTE2

16d ANTI-ROTATION
NAIL (TYP.)
5/8" DIAM. X 1'- 2"
BUTTON HEAD BOLT
WITH 7/32" OVAL GRIP - - AND RECESSED HEX NUT
WITH CUT WASHER (TYP.)

6 x 12 BLOCKOUT (TYP.)
-SEE NOTE2

.,.
...
/
./

5/8" DIAM. x 1 1/4" BUTTON HEAD


BOLT W/7/32" OVAL GRIP (TYP.)
AND RECESSED HEX NUTS
- 8 REQUIRED PER SPLICE

GROUND LINE

i
II
W6x8.5 x 6' - 0" OR
.....-1!
W6x9 x 6'- 0" ~ I!
LONG STEEL POST

! II
I !!

' !I

SECTION

5/8" DIAM. x 14" BUTTON HEAD


BOLT WITH 7/32" OVAL GRIP AND
RECESSED HEX NUT WITH
CUT WASHER (TYP.)

BEAM GUARDRAIL TYPE 31


DS (DOUBLE SIDED)
(W-BEAM)
STANDARD PLAN C-20.45-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

ISOMETRIC

5/8"

x 2" LONG BUTTON HEAD BOLT WITH 7/32"

1'- 0" MIN. COVER

OVAL GRIP, CUT WASHER, AND HEX NUT

>-

:g;

~ w
:::!: >>

=
0

NO BOLT
REQUIRED

2'- 3"

'

q.

D
OFFSET DISTANCE

oo
1D <(
<(

0::

H
NOT STEEPER
THAN 4H : 1V

NOT STEEPER
THAN 10H : 1V

NOT STEEPER
THAN 4H :1V

1'- 6" MAX.

SECTION

SECTION

SEE NOTE 3

PERSPECTIVE

LOCATION OF POST (WITHOUT BLOCK)


- W6 x 9 STEEL POST

W-BEAM RUB RAIL

EMBANKMENT \

. . . . . . ...

BURIAL POINT

EDGE OF WIDENED

...... . .

~~-TOP

BURIAL
POINT

LOCATION OF POSTS & BLOCKS (TYP.)

... . . .

NOTES
1. Posts installed on shoulder slopes steeper than 1OH : 1V shall be 8' long.

.OF CUT

3.

8 MIN. - SEE NOTE 2

...... ........................................ .

ANGLE POINT
- SEE NOTE 2

===--=======:J

2. The flare rate of the guardrail may be increased after crossing the ditch
bottom to shorten the length of the terminal.
Determine the height of the W-Beam at the Anchor (G) by first calculating
the perpendicular offset distance (D) from the edge of shoulder (S) to the
Anchor (on station). Multiply that distance by 0.1, then subtract the
product from the elevation of the same point (S) on the edge of shoulder
used to obtain the offset distance (at the same station). Add Beam
Guardrail design height (27") to that remainder for a sum that equals the
elevation of the top of the W-Beam at the Anchor.
Refer to SECTION "C":

\__ BOTTOM OF DITCH

Elevation G

FLARE RATE - SEE TABLE

(Elevations - D (0.1)) + 27

FIELD BEND

FLARE RATE TABLE


EDGE OF SHOULDER

RATE
PLAN
BEAM GUARDRAIL
TYPE 1
PAY LIMIT

BURIED TERMINAL TYPE 2 - PAY LIMIT


(TERMINAL LENGTH VARIES)
W-BEAM RAIL

TOP OF CUT

POSTED SPEED
(mph)

15 : 1

70

14 : 1

60

12 : 1

55

11 : 1

50

10 : 1

45

9 :1

Ill
11 1
11 1
1
1 1
1
:1

:~:

Ill
I I
I

:~:

W-BEAM RUB RAIL

U...!

i:i

}1,~

Ill
111
111

1
I
I
:

:::
111

lU

6'- 0" LONG (TYP)

:::
1 11
1
!1

BOTTO~~

OF DITCH

:l:

I
I
:

I
:
1

~~
~~

SEE NOTE 1 (TYP.)

6'- 0" LONG (TYP.)

ELEVATION
(PROFILE ALONG RAIL)

BURIAL
POINT
/::\

I I

1:
11
1 1
1
1 1
1:1

:
I
:

I
I
:

40 OR LESS

BEAM GUARDRAIL TYPE 1


BURIED TERMINAL TYPE 2

I
""!

~BEAM GUARDRAIL ANCHOR TYPE 2

~\_LOCATION ~~~~OST (~T::~Ts:::::RD

STANDARD PLAN C-22.14-02

PLAN C-6a

SHEET 1 OF 1 SHEET

- W6 x 9 STEEL POST
LOCATION OF POSTS & BLOCKS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

5/8"

x 2" LONG BUTTON HEAD BOLT WITH 7/32"

1'- 0" MIN. COVER

OVAL GRIP, CUT WASHER, AND HEX NUT

>-

:Z

~ ~~

OFFSET DISTANCE

= Ill<(
0 0

NO BOLT
REQUIRED

'

<( 0

"'"

0:::

vr===

H
NOT STEEPER
THAN 10H: 1V

NOT STEEPER
THAN 4H: 1V

NOT STEEPER
THAN 4H: 1V

1'- 6" MAX.

en
z
w
w

0:::

SECTION

Ill

SECTION

SECTION

....1
....1

SEE NOTE 3

iii

PERSPECTIVE

W6 x 9 STEEL POST WITHOUT BLOCK


BURIAL
POINT

W6 x 9 STEEL POST WITHOUT BLOCK

NOTES
1. Posts installed on shoulder slopes steeper than 1OH : 1V shall
be 8' long.

LOCATION OF POSTS & BLOCKS (TYP.)

2. The flare rate of the guardrail may be increased after crossing


the ditch bottom to shorten the length of the terminal.

BURIAL POINT
W-BEAM RUB RAIL
EDGE OF WIDENED
EMBANKMENT\

, _ 3" (TYP.)
6

~i
I

3. Determine the height of the W-Beam at the Anchor (G) by first


calculating the perpendicular offset distance (D) from the edge
of shoulder (S) to the Anchor (on station). Multiply that distance
by 0.1, then subtract the product from the elevation of the same
point (S) on the edge of shoulder used to obtain the offset
distance (at the same station). Add Beam Guardrail design
height (31 ")to that remainder for a sum that equals the elevation
of the top of the W-Beam at the Anchor.

8 MIN. -

\t

SEE NOTE 2

...................... ..........................................................................................................................................
ANGLE POINT
- SEE NOTE 2

\_ BOTTOM OF DITCH

FLARE RATE -SEE TABLE


FIELD BEND

Refer to SECTION "C":


Elevation G =(Elevations -

EDGE OF SHOULDER

D(0.1)) + 31

FLARE RATE TABLE

PLAN

BEAM GUARDRAIL
TYPE 31
PAY LIMIT

BURIED TERMINAL TYPE 2- PAY LIMIT


(TERMINAL LENGTH VARIES)
W-BEAM RAIL

BURIAL POINT
(TYP.)

TOP OF CUT

RATE

POSTED SPEED
(mph)

15 : 1

70

14: 1

60

12: 1

55

11 : 1

50

10 : 1

45

9: 1

40 OR LESS

!!i

iii

BOTTOM OF DITCH

6' -0" LONG


(TYP.)

BEAM GUARDRAIL TYPE 31


BURIED TERMINAL TYPE 2
BEAM GUARDRAIL ANCHOR TYPE 2
- SEE STANDARD PLAN C-6a

STANDARD PLAN C-22.16-03


SHEET 1 OF 1 SHEET

W-BEAM RUB RAIL

APPROVED FOR PUBLICATION


LOCATION OF POSTS & BLOCKS
- W6 x 9 STEEL POST

SEE NOTE 1 (TYP.) _;

ELEVATION
(PROFILE ALONG RAIL)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

NOTES
Cl

0::

1. These terminals are FHWA accepted at Test Level Three (TL-3) and may be used for all posted speeds.

LL.

~
en

2. An ET-31 (Steel) as manufactured by Trinity Industries, Inc. or an SKT-SP-MGS as manufactured by Road Systems Inc. shall be installed according to
manufacturer's recommendations.

:;..:

3. A reflectorized object marker shall be installed according to manufacturer's recommendations.

4. When snow load post washers and snow load rail washers are required by the contract, the snow load rail washers shall not be installed within the terminal limits.

<(

::::i

Ill

5. Terminal shall be installed at a widening, ensuring that the end piece is entirely off the shoulder. While these terminals do not require an offset at the end, a flare
is recommended. A maximum flare of 25 : 1, or flatter over the length of the terminal is allowed for either the ET-31 (Steel) or the SKT-SP-MGS, with a maximum
offset of 24" (in.) over 50' (ft.).

Cl

6.

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

For Terminal details, see WSDOT approved manufacturer's drawings.

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL ET-31 (STEEL) SHOWN - SEE NOTE 2

----------------

10'- 0" MIN.

"I"

"I

EDGE OF WIDENED
EMBANKMENT

""""mum~ mmomomom:~::n~~-~~~-~~-~~;~;;~~""~. ~"""


IIIII::

~--------

(RELATIVE TO GRADE)
10H : 1V SLOPE OR FLATTER

SEE NOTE 5

PLAN VIEW

EDGE OF SHOULDER

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

SKT-SP-MGS (TL-3) SYSTEM LENGTH= 40'- 7 1/2"


(SEE NOTE 5)

I
SEE NOTE 3

111
111
111
111
111
111
111
I.LI

111
111
111
111
111
111
Ill
I.LI

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

I.LI

I.LI

I.LI

I.LI

I.LI

I.LI

ELEVATION VIEW

SKT-SP-MGS
BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL- PAY LIMIT

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

ET-31 (STEEL) (TL-3) SYSTEM LENGTH= 40'- 7 1/2"


(SEE NOTE 5)
SEE NOTE 3

111
111
111
111
111
111
111
I.LI

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

111
111
111
111
111
111
111

I.LI

I.LI

I.LI

I.LI

I.LI

I.LI

I.LI

ELEVATION VIEW

ET-31 (STEEL)

BEAM GUARDRAIL TYPE 31


NON-FLARED TERMINAL
STEEL POSTS
(ALL POSTED SPEEDS)
STANDARD PLAN C-22.40-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-16-10
DATE

Washington State Department of Transportation

NOTES
1. These Terminals are FHWA accepted at Test Level Two (TL-2) and may be used in applications with speeds of 40 MPH or less.
2. An ET-31 (TL-2) as manufactured by Trinity Industries, Inc. or an SKT-SP-MGS (TL-2) as manufactured by Road Systems Inc.
shall be installed according to manufacturers' recommendations.
3. A reflectorized object marker shall be installed according to manufacturers' recommendations.
4. When snow load post washers and snow load rail washers are required by the Contract, the snow load rail washers shall not be
installed within the Terminal limits.
5. Terminal shall be installed at a widening, ensuring the end piece is entirely off the shoulder. While these Terminals do not
require an offset at the end, a flare is recommended. A maximum flare of 25 : 1 or flatter over the length of the Terminal is
allowed for either the ET-31 (TL-2) or the SKT-SP-MGS (TL-2), with a maximum offset of 24" (in.) over 50' (ft.).
6.

I BEAM

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

For Terminal details, see WSDOT-approved manufacturers' drawings.

GUARDRAIL TYPE 31 NON-FLARED TERMINAL ET-31 (TL-2) SHOWN - SEE NOTE 2

10'- 0" MIN.

------------------------------------------------------------------~~------------------------------------------~--~-----------------+---------------------~

--"

.-"

---

-""

"j1.

EDGE OF

~DENED

EMBANKMENT

--~n;~:;~~:~:~-~;-;;:;.;:;;;,.--.~~:

--------------

(RELATIVE TO GRADE)

---------------------10H : 1V SLOPE OR FLATTER


SEE NOTE

PLAN VIEW

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

EDGE OF SHOULDER

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL - PAY LIMIT


SKT-SP-MGS (TL-2) SYSTEM LENGTH
(SEE NOTE 4)

= 28'- 1

1/2"

I
SEE NOTE 3

Ill

11 1
11 1
11 1
11 1
11 1
11 1
11 1

111
Ill
Ill
Il l

111
Il l
l.1. l

l.1.l

111
111
111
111
111
111
111
l.1.l

111
111
111
11 1
111
111
11 1

111
111
111
111
111
111
111

I .I. I

I .I. I

111
111
111
111
111
111
111
l.1.l

11 1
11 1
11 1
111
111
11 1
111
l.1.l

ELEVATION VIEW

SKT-SP-MGS (TL-2)
BEAM GUARDRAIL TYPE 31 - PAY LIMIT

BEAM GUARDRAIL TYPE 31 NON-FLARED TERMINAL - PAY LIMIT


ET-31 (TL-2) SYSTEM LENGTH
(SEE NOTE 4)

_-~----......

111
111

I I

'

Iii

~--- 1 ~ 1

11 1
11 1

111
111

I I

I I

I I

111
111

1/2"

I
SEE NOTE 3

r-.

1!1

= 28'- 1

1!1

Iii

111
111

I I

1:
1!1

1!1

111
111

111
111

I I

11 1
11 1

I I

I I

1!1
11
1 11
1 I
1:1
1 11
1 11
1 11
I.JJ

ELEVATION VIEW

ET-31 (TL-2)

........_I![V

BEAM GUARDRAIL TYP


NON-FLARED TERMINAL
STEEL POSTS (POSTED SPEED
- 40 MPH AND BELOW)
STANDARD PLAN C-22.45-00
SHEET 1 OF 1 SHEET

I I
!II
I I

:I:

I I

I I
I I
1'1
111

It I

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

~ Washington Stale Department of Transportation

NOTES
1. For use on the end of guardrail runs when a crashworthy terminal is not required.
BEAM GUARDRAIL TYPE 31

- PAY LIMIT

BEAM GUARDRAIL ANCHOR TYPE 10

6'-3"

3'- 1 1/2"

6'- 3"

3'- 1 1/2"

- PAY LIMIT

3'- 1 1/2"

ANCHORPLATE
(SEE NOTE 2)

l
~

'

'

'

u.

!
:1:

4. Use details for Wood Breakaway post shown on this plan and components
shown on Standard Plan C-1 b.
5. Fasten the Anchor Cable using two 1" nuts and washer, at both ends of cable.
Outside nut shall be torqued against inside nut a minimum of 100 ft.-lbs.

OOD BREAKAWAY POST

EARING PLATE (SEE NOTE 2)

lb.=

=I

C'\1

3. For end section details, see Standard Plans C-7 and C-7a.

END SECTION DESIGN C


(SEE NOTE 3)

~w

,t /Iii\_
J-i--~

il

ANCHOR RAIL WASHER


-ON TRAFFIC SIDE
(SEE NOTE 2)

ANg:B~~~

0:::
0

i
i1'- 0" 1'- 4"

I
N

2. For additional details not shown, see Standard Plan C-6c.

6'- 3"

GROUND LINE

6. Wood blocks shown. Blocks of alternate material may be used. See


Standard Specification 9-16.3(2).

5 1/2"

-l,F

SEE NOTE 5

PIPE SLEEVE
(SEE NOTE 2)

7 1/2"

------.--.-

~~-~

~-
;

3/4" HOLES
ANCHOR POST ASSEMBLY
(SEE NOTE 4)

_/[_f-

2 3/8"
HOLE

ELEVATION VIEW
6x8
S4S

W-BEAM

6'-3"

BEAM GUARDRAIL ANCHOR TYPE 10- PAY LIMIT


3'- 1 1/2"

6'- 3"

3'- 1 1/2"

6'- 3"
3'- 1 1/2"

i
i1'- 0" 1'- 4"

!
ANCHOR PLATE
(SEE NOTE 2)

-- -- (<)

-~r

WOOD BREAKAWAY
POST DETAIL

ISOMETRIC VIEW
BEAM GUARDRAIL TYPE 10 OR 11- PAY LIMIT

ANCHOR RAIL WASHER


-ON TRAFFIC SIDE (SEE NOTE 2)
END SECTION DESIGN C

V
~~~~~~~~~~fi~~~~~~~~~~fil,~~~~~~~~~~~il'i~~~~~~~iiii;i~~~~~~~i1~~(SEENOTE3)
~

ii
m

m
m

:i:
m
m

PIPE SLEEVE
(SEE NOTE 2)

:!:
:!:

m
:!:

i
l-"

GROUND LINE

=~t;!J-i--t1\_ SEE NOTE 5

:!

BEARING PLATE (SEE NOTE 2)

i ANg:B~~ ~---~ r

WOODBREAKAWAYPOST

T"

T"

ANCHOR POST ASSEMBLY


(SEE NOTE 4)

BEAM GUARDRAIL (TYPE 31)


ANCHOR TYPE 10

_/[_L.

ELEVATION VIEW

STANDARD PLAN C-23.60-02

THRIE BEAM

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC VIEW

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

NOTES
TRANSITION SECTION PAY LIMIT

1.

Attach guardrail to bridge rail or concrete barrier with 7/8" diameter bolts in
accordance with Standard Spec. 9-06.5(4), with thin slab ferrule inserts
or resin bonded anchors. See Contract Plans.

2.

If the last guardrail post is 3" or less from the end of the bridge barrier, this
attachment and blackout is not necessary.

c
c

3.

This case is also applicable for F-shape and vertical faces with no curbs.

::::i

4.

When B connection is used with Type 1A Transition, the maximum spacing


between bolts is 6'- 3".

5.

See Bridge Plans for additional connection details.

6.

Wood blocks shown. Blocks of alternate material may be used.


See Standard Specification 9-16.3 (2).

6'- 3" MAX.

3' - 1 1/2 "


MAX.

UNRESTRAINED
PRECAST BARRIER
....1
....1

0::

w
u.

SEE NOTE 1

END SECTION DESIGN F


SEE STD. PLAN C-7 & C-7a

FACE OF GUARDRAIL,
EDGE OF SHOULDER

PLAN

NEW BRIDGE
TRAFFIC BARRIER
{SINGLE SLOPE
BARRIER SHOWN)

TRANSITION SECTION PAY LIMIT


3'- 1 1/2" MAX.

I'

SEE NOTE 4

'I

A CONNECTION

END SECTION DESIGN F


SEE STD. PLAN C-7 & C-7a

TRANSITION SECTION PAY LIMIT

SEE NOTE 5

FACE OF GUARDRAIL,
EDGE OF SHOULDER

PLAN
12'- 6"

BRIDGE RAIL OR
CONCRETE BARRIER

3'- 1 1/2" MAX.


SEE NOTE 4

BRIDGE TRAFFIC
BARRIER

{SEE NOTE 3)

END SECTION DESIGN F


SEE STD. PLAN C-7 & C-7a

FACE OF GUARDRAIL,
EDGE OF SHOULDER

SEE NOTES 1 & 2

END SECTION DESIGN F


SEE STD. PLAN C-7 & C-7a

TRANSITION SECTION PAY LIMIT

D CONNECTION

6'- 3" MAX.

PLAN

E CONNECTION

PLAN
CURB WIDTH - 9" OR LESS,
OR CONCRETE BARRIER

B CONNECTION
BEAM GUARDRAIL PAY LIMIT

6'- 3" MAX.

TRANSITION SECTION PAY LIMIT

6'- 3"

6'- 3"
END SECTION DESIGN F
SEE STD. PLAN C-7 & C-7a

BRIDGE RAIL OR
CONCRETE BARRIER

INSIDE FACE OF RAIL BASE


..- ONE-WAY TRAFFIC
PLAN

F CONNECTION
END SECTION DESIGN F
SEE STD. PLAN C-7 & C-7a

CURB WIDTH, GREATER


THAN 9" - 18" MAX.

SEE NOTE 1

PLAN

C CONNECTION

GUARDRAIL CONNECTION
TO BRIDGE RAIL
OR CONCRETE BARRIER
STANDARD PLAN C-24.10-00
SHEET 1 OF 1 SHEET

FACE OF GUARDRAIL,
EDGE OF SHOULDER

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

NOTES

23'- 0"

12'- 0"

1. For additional details not shown in this plan, refer to


Standard Plan C-20.1 0.
2. This guardrail transition is for connection to a vertical
concrete shape or single slope barrier and cannot be
connected directly to a concrete safety shape.
3.

...J
...J

Cl
Cl

:J

EMBANKMENT WIDTH W- SEE


TABLE, STANDARD PLAN C-20.10

NESTED W-BEAM GUARDRAIL

a::

PLAN VIEW

u...

BEAM GUARDRAIL TRANSITION SECTION TYPE 20 {FOR TYPE 31) - PAY LIMIT
FOUR SPACES@ 18 3/4"

FOUR SPACES @ 3' - 1 1/2"

BEAM GUARDRAIL TYPE 31


-PAY LIMIT

6'- 3"

Do not bolt nested W-Beam or rubrail W-Beam to posts


and blocks on posts 1,2,3 and 5. Bolt tapered
blocks directly to posts.

4. The rubrail W-Beam can be shop bent to facilitate


installation.
5.

Posts 1,2,3,4 and 6 require an additional hole to attach


tapered blocks and/or rubrail.

6.

Posts 1 and 2 are W6x15 steel posts- 7'- 6" long.


Posts 3 through 9 are W6 x 9 steel posts - 6' - 0" long.

NESTED W-BEAM GUARDRAIL {UPPER RAIL ELEMENT)

W-BEAM GUARDRAIL

.I.

I
I

7. Wood blocks shown. Blocks of alternate material may


be used. See Standard Specificdation 9-16.3(2).

GROUND LINE

TAPERED BLOCKS
-SEE DETAIL

I
I

I
I

1:

'I.:

:I':
I

I':

I I
I

ru'I'

l~J

:~J

'I'
I,:
I

W-EJEAM RUBRAIL

'I'
'I'
I

II"

'I'
Lr'

II

I
I
I" I

II

I. :

:II:

:I.:

~
'I'

I
I
I o I
I
I
I I

I
I
I. I

'I'
Lr'

LU

Lr'

'I'
'I'
I'
~

'I'
Lr'

PLAN VIEW

SEE NOTE 5

TAPERED BLOCKS FOR RUBRAIL DETAIL

ELEVATION VIEW

14" LONG {TYP.)

3/4" DIAM. HOLE

2'- 6"

{END OF BARRIER)

NESTED W-BEAM
GUARDRAIL {TYP.)

. 4" 4"

-~~
~
.....
C')

~
.....

'

C')

.....

~
.....

I I

BOLT LOCATION DETAIL


FOR STEEL POST

,...
'~
"""~

TAPERED BLOCK
-SEE DETAIL

GROUND
LINE {TYP.)

."T~

i I I

t .
--tf- ~
A,~

BEAM GUARDRAIL (TYPE 31)


TRANSITION SECTION
TYPE 20
STANDARD PLAN C-25.18-03

y~

<J)

DETAIL

SHEET 1 OF 1 SHEET
(OR)

SECTION

(STEEL POST)

APPROVED FOR PUBLICATION

SECTION

(STEEL POST)

Pasco Bakotich Ill


OBLIQUE VIEW

II

- .------,ST=AT=E""'DE=SI=GN.,..,E'""NG""IN-EE-R--...

0712112
DATE

~ Washington State Department of Transportation

....1
....1

NOTES

LlJ

Cl
Cl

1. This guardrail transition is for connection to a vertical concrete shape, a single slope,
or a safety shape barrier. The toe of the single slope and the safety shaped barrier
shall be tapered or the barrier blocked out so that the toe of the barrier does not
project past the face of the approach guardrail.

::::i

a::
LlJ
LL.

2. See Standard Plan C-24.1 0 for details regarding connection to Bridge rail or traffic barrier.

Cl

3.

For details of typical components, see Standard Plans C-1 b and C-20.1 0.

BEAM GUARDRAIL TRANSITION SECTION TYPE 21 - PAY LIMIT


NOTE: TRANSITION PAY LIMIT SHALL INCLUDE END SECTION FOR CONNECTION TO BARRIER OR FIXED OBJECT
SEE CONTRACT PLANS
FOR SPECIFIED
CONNECTION

12 SPACES@ 3'- 1 1/2"

I
I

12'- 6"
NESTED THRIE
BEAM GUARDRAIL
12 GAGE

I
-l

6'- 3"
SHORTTHRIE
BEAM ELEMENT
12 GAGE

BEAM GUARDRAIL TYPE 31


PAY LIMIT

-l

REDUCER ELEMENT
TYPE C
10 GAGE

~Il
-

-l

W-BEAM GUARDRAIL
12 GAGE

I
I

-L

Co

6'- 3"

. I

-1-

-1-

I .

3' - 1 1/2"

.J.~

.J.

Ill
I, I

f...

'

'

I! I
1l1
I, I
I'I'I
I 'I
I I
'I'
I I

I+'
I
I I

I"

I! I

I! I

rl

I! I

I'I'I
I' I
I I
I

1l1
I, I

Ill
I I

Ill
I, I

I'I'I
I 'I

I I

'I'

I'I'I

I, I

'I'

I I
I, I

I,
'I'

I' I
I I
I, I

'+I

W6x15- 7'- 0" LONG


STEEL POST
WITH 6x8 BLOCK

I
I

'I'
'I'

I
I

I+'
I
I I

''

'I' 1I

I
I

I' I

'1'

!I\

~!I

I:, I
I:

, I

I:'I

'I'

111

I' I

'1'

I
I
I

I I
1

; 11

, I

:1:

I I

I I

I I

,-

'1'

I' I

'I'
I

W6x 9 - 6' - 0" LONG STEEL


POST WITH 6x 12 BLOCK

LEFT
(MIRROR OF RIGHT)

7' - 3 1/2"

"

7' - 3 1/2"

3' - 1 1/2"

3' - 1 1/2"

.
1'- 0 1/4"

3/4" X 2 1/2"
SLOT (TYP.)

'I'

'

DETAIL

GROUND LINE

I'I'I
I I

I"

3/4" X 2 1/2"
SLOT (TYP.)

I
I

1-

DETAIL

I
I

I I
I' I

W6x12- 7'- 6" LONG STEEL POST


WITH 6x 12 BLOCK

"I

I
I
I
I
I

'I'II

I
I,
I
I

I
I
I

I I
I' I

'1'

I:

I I
I' I

'1'

I:

Ill
I, I

II \ _
II
I
I,
I,
I, I
I I
111
111
I II
6x12x19" LONG BLOCK
I I
- SEE DETAIL STD. PLAN C-25.22

----1..--

/,

3/4" DIAM. HOLE


THROUGH BLOCK
(TYP.)

I"

'

3 1
' - ,,.

i"I

~~s)~~:~l==z[

BEAM GUARDRAIL (TYPE 31)


TRANSITION SECTION
TYPE 21
STANDARD PLAN C-25.20-05
SHEET 1 OF 1 SHEET

SYMMETRICAL
ABOUT

ft

RIGHT

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

THRIE BEAM WOOD BLOCK

REDUCER ELEMENT TYPE C

SHORT THRIE BEAM ELEMENT

NOTES

rn
z
w
w

1. See Standard Plans C-1 b, C-1 d, C-20.1 0 and C-25.20 for rail elements
and thrie beam block details.

0::
al
....1
....1

2. When a transition is required on the trailing end of the bridge, use a mirror
image of this plan.

ii5
:;>..:
al

13 SPACES@ 3'- 1 1/2"


DISTANCE FROM '
BRIDGE END - VARIES

BEAM GUARDRAIL TRANSITION SECTION TYPE 22- PAY LIMIT


50'- 0"

BRIDGE RAIL THRIE BEAM


RETROFIT (10 GAGE)
,

r-

SHORT THRIE BEAM


ELEMENT (6' - 3")
(12 GAGE)
BRIDGE TRANSITION
I
RAMP (HMA)

12'- 6" NESTED THRIE BEAM (12 GAGE)

= 40'- 7 1/2"

6'- 3"

THRIE BEAM GUARDRAIL


REDUCER SECTION
TYPE B (10 GAGE)

W-BEAM GUARDRAIL (12 GAGE)

111

I
I
I
I
I
I
I
I
I
I

:I:
I
I

I
I

6 x 12 x 19" LONG
BLOCK- SEE DETAIL

I:'1.
'I'
:I
I

Ill
I

l11

I
~

'I

!.

W6 x 15- 7'- 0" LONG


STEEL POST WITH 6 x 8 BLOCK

BEAM GUARDRAIL TYPE 31


PAY LIMIT

'I

I:'1.
II'

~~

11 1
II

II

: 1
I
1

ll_)

'I

W6 x 12- 7'- 6" LONG

i.

STEEL POST WITH 6 x 12 BLOCK


(EXCEPT AS NOTED)

,,

,,

I!,,

I!,,

~j

~j

W6 x 9 - 6' - 0" LONG


STEEL POST WITH 6 x 12 BLOCK

'I

TYPE22
APPROACH END (SHOWN - SEE NOTE 2)
THRIE BEAM INSTALLED AT FACE OF BRIDGE RAIL

l_s-

EDGE OF TRAVELED WAY

I
I

VARIES
1'- 6" MIN.

BRIDGE RAIL THRIE


BEAM RETROFIT

I
I

EXISTING BRIDGE RAIL

I.IN
I
I
I

...

:.:::.~_,:. ,:.~:~.::.::.~.~.:.:.:,.~~.: ~

~-.. ...... . BRIDG.E :.


II-

I>

..

.. -

..

..

~..-.~

..

I>

..

3/4" DIAM. HOLE


THROUGH BLOCK
(TYP.)

BEAM GUARDRAIL (TYPE 31)


TRANSITION SECTION
TYPE22
STANDARD PLAN C-25.22-04
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SECTION

THRIE BEAM REDUCER


WOODBLOCK

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

....1
....1

NOTES

0
0

1. See Standard Plan C-1 b, C-20.1 0 and C-25.20 for rail elements and thrie beam
block details.

::::i

0:::

11..

2. When a transition is required on the trailing end of the bridge, use a mirror image
of this plan.
3. For additional alternatives not shown, see Contract Plans.

.BRIDGE RAIL THRIE BEAM

.I.

RETROFIT (10 GAGE)

13 SPACES@ 3'- 1 1/2"


DISTANCE FROM,

6'- 3"

NESTED THRIE
BEAM GUARDRAIL

..

12 GAGE

SHORTTHRIE
BEAM ELEMENT

J.

REDUCER ELEMENT
TYPEC

10 GAGE

. i.

. i.

12 GAGE

l
Co

' ...................... .............

BRI DGECURB _ /

12 GAGE

~l

PAY LIMIT

6'- 3"

.1. -----

rl

rl

ril
I

\_

:I:

=_}

T
''
'I'
''
''il''i

''
''
''
:I:
''

-r

~~

---~

''
,.,
...
i
E)(:TRUDED CUR,B
i
'' ''
'' ''
''
'

.I,

W6 X 15- 7'- 0" LONG


STEEL POST WITH 6 x 8 BLOCK

Ill

\:i:
I

a'~

I
:i:
I

12 x_19" LONG
BLOCK SEE DETAIL
STD. PLAN C-25.22

I
I

:I:

'' ''
''
:1:
': 'J

''
:1:
': 'J

ij.lJi

l.

:I:

'' ''
''
:1:
': 'J

'

I
''
''
''
''
''
'
'
''
'

'jj

'

I
I

12- 7'- 6" LONG


STEEL POST WITH 6 x 12 BLOCK
W6

I"

F--

r1

..

W-BEAM GUARDRAIL

'

BEAM GUARDRAIL TYPE 31

BRIDGE END - VARIES j

~
Co

'

BEAM GUARDRAIL TRANSITION SECTION TYPE 23- PAY LIMIT

' __-:...-

''
''
''
''
''
'

~i
I
I
I

iji' '

''
::
:!.'':'

:i''''' ''
':
:1,

,.

~t:

~t-:

''
''
''
''
''
'

:i:''' '

'I'

i.i

li

iii

~i

GROUND Ll NE

:i:

:i:
:'
''

:'
''

iji
''
':
il':
''
iii
~t:

iji
''
':
il':
''
iii
~t:

I
W6 X 9 - 6' - 0" LONG
STEEL POST WITH 6 x 12 BLOCK

(EXCEPT AS NOTED)

r-s-

TYPE 23
EDGE OF TRAVELED WAY
VARIES

1'- 6" MAX.

APPROACH END (SHOWN - SEE NOTE 2)


THRIE BEAM INSTALLED AT FACE OF CURB

l_s-

EDGE OF TRAVELED WAY


VARIES

I
I

BRIDGE RAIL THRIE


BEAM RETROFIT

I
I

1'- 6" MIN.


BRIDGE RAIL THRIE
BEAM RETROFIT

EXISTING BRIDGE RAIL

EXISTING BRIDGE RAIL

leo

IN

BEAM GUARDRAIL (TYPE 31)


TRANSITION SECTION
TYPE 23
STANDARD PLAN C-25.26-02

I
I
I
A'

-., '

"'.

SECTION

SHEET 1 OF 1 SHEET

ALTERNATIVE 1

SECTION

ALTERNATIVE 2

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

C')

w
0

....1
....1

1-

0
0

w
w

::::i

(/)

0:::

11..

HINGE POINT

-------------------------------------""':_- ----------------------------------------------------------------------------------------------------------------------------------------------1....... ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------z-----------------EMBANKMENT WIDTH W- SEE


TABLE, STANDARD PLAN C-20.10

~
0

'

FACE OF BARRIER
EDGE OF SHOULDER
-SEE NOTE 3

PLAN VIEW

BEAM GUARDRAIL TYPE 1


-PAY LIMIT

BEAM GUARDRAIL TYPE 31 - PAY LIMIT

BEAM GUARDRAIL TYPE 31 TO BEAM GUARDRAIL TYPE 1 ADAPTER


28' - 1 1/2"

6'- 3"

6'- 3"

6'- 3"

-~-----...

I
6'- 3"

3' - 1 1/2"

.i.

l .----------

(t)

01

Ol

'

"f

C'-.1

----------- i

I ' I
I

T
I

GROUND LINE

01

t-'

C'-.1

I ' I

I ' I

I ' I

I ' I

\_MIDSPAN
SPLICE

I
I

--c.-

I 1
I , I

ELEVATION VIEW- PROFILE TAPER

NOTES
1. Refer to Standard Plan C-1 and C-1 b for component details
for Beam Guardrail Type 1 not shown on this plan.
2. Refer to Standard Plan C-20.1 0 for component details for
Beam Guardrail Type 31 not shown on this plan.
J: -

1- .....
0 z

;;:

....1

I-

FACE OF BARRIER
EDGE OF SHOULDER

0::: 1w 0:::
0 w

3. Where post off-set is constrained, and when the existing


shoulder will not be widened and is wider than 4 feet, the
existing shoulder may be reduced up to 4" to accomodate
the 12" blackouts of the Beam Guardrail Type 31. See
PLAN VIEW- ALIGNMENT TAPER.

::Ji1j
00:::

V5C>

PLAN VIEW- ALIGNMENT TAPER


SEE NOTE 3

BEAM GUARDRAIL TYPE 31


TO BEAM GUARDRAIL TYPE 1
ADAPTER
STANDARD PLAN C-25.80-02
SHEET 1 OF 1 SHEET

4. Wood blocks shown. Blocks of alternate material may


be used. See Standard Specification 9-16.3(2).

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 1)

BEAM GUARDRAIL TYPE 10

BEAM GUARDRAIL BULL NOSE TERMINAL (DESIGN 1)

PAY LIMIT

PAY LIMIT

PAY LIMIT
DIRECTION OF TRAFFIC

EDGE OF TRAVELED WAY

CLEAR AREA - SEE


STANDARD PLAN C-4f

EDGE OF SHOLDER \

HIGH TENSION
CABLE BARRIER

---------------------------- .\_------------------------------

.. 7
HIGH TENSION
CABLE BARRIER

"

-@
~------------------------------------------------------

CLEAR AREA - SEE


STANDARD PLAN C-4f

,
_

\_ EDGE OF SHOULDER

DIRECTION OF TRAFFIC

....1
....1

PLAN VIEW

::J

CASE 9A

0
0

z
c:::

-,---------------------------------------------------

EDGE OF TRAVELED WAY

11..

DIRECTION OF TRAFFIC

EDGE OF TRAVELED

EDGE OF SHOULDER

LEGEND

WAY

Design Layout Line

-------------------------------------------------------------------------------------------------------------------------~~---------------------

/'__

THRIE BEAM
BULL NOSE

1~

MAX. DEFLECTION
-AS SHOWN IN
CONTRACT PLANS

--------------------------------~-----------------------~~~J~~----------------------------------------------i-----~------------------i
EDGE OF SHOULDER
1

BARRIER PLACEMENT
CABLE TO THRIE BEAM
BULL NOSE CONNECTION
STANDARD PLAN C-40.14-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

LENGTH OF NEED

DIRECTION OF TRAFFIC

IiI

CABLE BARRIER TERMINAL

.I

EDGE OF TRAVELED
WAY

Pasco Bakotich Ill

......

PLACEMENT DETAIL

STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

DIRECTION OF TRAFFIC

BEAM GUARDRAIL ANCHOR


TYPE 10 PAY LIMIT
BEAM GUARDRAIL TYPE 31 PAY LIMIT

BEAM GUARDRAIL
NON- FLARED TERMINAL PAY LIMIT

....1
....1

0
0

EDGE OF TRAVELED WAY

::::i

z
c:::

CABLE BARRIER MINIMUM TAPER LENGTH

W-BEAM GUARDRAIL

LL.

LENGTH OF NEED

MAX. DEFLECTION
-AS SHOWN IN
CONTRACT PLANS

20 MIN.

25
20 MIN.

LENGTH OF NEED

W-BEAM GUARDRAIL

.i

BEAM GUARDRAIL ANCHOR


TYPE 10 PAY LIMIT- SEE
STANDARD PLAN C-23.60

CABLE BARRIER MINIMUM TAPER LENGTH


EDGE OF TRAVELED WAY

BEAM GUARDRAIL TYPE 31 PAY LIMIT

BEAM GUARDRAIL
NON- FLARED TERMINAL PAY LIMIT
DIRECTION OF TRAFFIC _.

PLAN VIEW

LEGEND
Design Layout Line

BARRIER PLACEMENT - CABLE


TO W-BEAM SHIELDING FOR
REDIRECTIONAL LANDFORM
STANDARD PLAN C-40.16-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

0712112
DATE

~ Washington State Department of Transportation

....1
....1

0
0

::::i

LEGEND

0:::

Design Layout Line

11..

LENGTH OF NEED

I.
CABLE BARRIER TERMINAL

.I

DIRECTION OF TRAFFIC

EDGE OF TRAVELED
WAY

HIGH TENSION CABLE


BARRIER

MAX. DEFLECTION - AS SHOWN


IN CONTRACT PLANS

25
25

MAX. DEFLECTION - AS SHOWN


IN CONTRACT PLANS

DIRECTION OF TRAFFIC p:za

EDGE OF TRAVELED
WAY

HIGH TENSION CABLE


BARRIER

LENGTH OF NEED

I
I

CABLE BARRIER TERMINAL

PLAN VIEW

MAX. DEFLECTION -AS SHOWN


IN CONTRACT PLANS
EXISTING BRIDGE PIER

EXISTING REDIRECTIONAL
LANDFORM

HIGH TENSION
CABLE BARRIER

EDGE OF TRAVELED WAY

II
II
II
II
II

BARRIER PLACEMENT - CABLE


BARRIER SHIELDING FOR
REDIRECTIONAL LANDFORM
STANDARD PLAN C-40.18-02
SHEET 1 OF 1 SHEET

I
I
I

lc=>j----..J

SECTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

0712112
DATE
.

~ Washington State Department of Transportation

NOTES
20' - 0"

___!j_r

~----------------------------------------------~ -

#8 BAR (TYP .)

~1

PLAN

#6 BAR (TYP .)
TACK WELD
(TYP.)

1.10 1/2"

REBAR GRID DETAIL


FOR PERMANENT INSTALLATION

G)&@- 3 SPACES @4" = 1'- 0"


@- 4 SPACES @ 6"

G)&@- 3 SPACES@ 4"

=2' - 0"

@- 4 SPACES @ 6"

8"

@- 12 SPACES@ 12"

1. PERMANENT INSTALLATION requirements: Embed


barrier 3" minimum, install 1/4" Premolded Joint Filler
between segments, fill the Connection Blackout with
grout, centering the Rebar Grid in the blackout before
adding grout.
2. TEMPORARY INSTALLATION requirement: Place a
Rebar Grid in the Connection Blackout between barrier
segments.
3. Installation on a horizontal curve with a radius less than
2000' requires a modified end design.
4. For Barrier with a 2' - 10" reveal, see sheet 2.
For High-Performance Barrier with a 3' - 6" reveal,
see sheet 3.

=1'- 0"

=2' - 0"

=12'- 0"

8"

CONNECTION BLOCKOUT
FILL VOID WITH GROUT

REBAR GRID
-SEE DETAIL

--=t=W+--+-----+-----+----+----+------+-IIII I I I I I
j__Jj_j__j__j_j_j__j

I.

3' -4"
(TYP.)

r--;;r

.I

5'- 0"
(TYP.)

2G) (TYP.)

MARK

REINFORCING
SIZE

WELDED WIRE
REINFORCING

CD

#4

D -20

#4

D -20

#5

D- 31

TOP OF
ROADWAY

1/4" PREMOLDED JOINT FILLERFOR PERMANENT INSTALLATION

#8 BAR (TYP .)
1/4" PREMOLDED JOINT
FILLER - FOR PERMANENT
INSTALLATION

BARRIER CONNECTION DETAIL

ELEVATION

WELDED WIRE REINFORCING


SUBSTITUTION OPTION TABLE

#6 BAR (TYP.)

FOR PERMANENT INSTALLATION

TOP OF BARRIER

* WELDED WIRE REINFORCMENTS SHALL


CONFORM TO STANDARD SPECIFICATION
SECTIONS 6-10 and 9-07

PREPARED GRADED BASE


HYPOTHETICAL GRADE DIFFERENTIAL

REINFORCING STEEL BENDING DIAGRAM

BARRIER TRANSITION DETAIL

SINGLE-SLOPE
CONCRETE BARRIER
(PRECAST)
STANDARD PLAN C-70.10-00

DIMENSION TABLE
A

HORIZONTAL
BARS (QTY.)

3'- 6"

8"

2'- 0"

2'- 8"

2'- 10"

1' -7"

4'-0"
SEE DIMENSION TABLE

SHEET 1 OF 3 SHEETS

BARRIER
HEIGHT

4'-6"

9 1/8"

2'-21/4"

10 1/4" 2'-41/2"

4
5

3'- 2"
3'- 8"

3'- 4"

1'- 9"

3'- 10" 1'- 11"

10
12

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

3/4" CHAMFER (TYP.)


11/2" CLR.

en

b
.....
'

en

:ij

C\1

C<?

TOP OF
ROADWAY

TOP OF
ROADWAY

SECTION

SECTION

3'- 6" BARRIER


SHOWN LEVEL

3' - 6" BARRIER FOR USE WITH A


0" TO 5" MAX. GRADE SEPARATION

3/4" CHAMFER (TYP.)

en

:ij

.....

<(

b
'

TOP OF
ROADWAY

c..

en
__.
::::>

TOP OF
ROADWAY

"'"

0
w

'

"'"

10

=:::;-:=-I==;::==--

GRADE SEPARATION
?"MAX.

:z:~
~:2
b&>
..... '

.....

_f

TOP OF
ROADWAY

GRADE SEPARATION
10" MAX.

.....

SECTION

SECTION

4'- 0" BARRIER FOR USE WITH A


GREATER THAN 5" TO 7" MAX.
GRADE SEPARATION

4'- 6" BARRIER FOR USE WITH A


GREATER THAN 7" TO 10" MAX.
GRADE SEPARATION

SINGLE-SLOPE
CONCRETE BARRIER
(PRECAST)
STANDARD PLAN C-70.10-00
SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

STANDARD MOUNTING HEIGHT

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

3/4" CHAMFER (TYP.)


9" CLR. (TYP.)

CIJ

CIJ

~ ~

TOP OF
ROADWAY

TOP OF
ROADWAY

0
w
v

TOP OF
ROADWAY
TOP OF

-"---'--------:::!=..{==f.-~7'---=t:=.t~-11------. --'------.--- _L ROADWAY


GRADE SEPARATION
3"MAX.

2'- 2 1/4"

SECTION

4' - 0" BARRIER


SHOWN LEVEL

-~

co

SECTION

4'- 0" BARRIER FOR USE WITH A


0" TO 3" MAX. GRADE SEPARATION

GRADE SEPARATION
6"MAX.

~~
~ =
= 0
'

.....

SECTION

4' - 6" BARRIER FOR USE WITH A


GREATER THAN 3" TO 6" MAX.
GRADE SEPARATION

SINGLE-SLOPE
CONCRETE BARRIER
(PRECAST)
STANDARD PLAN C-70.10-00
SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

HIGH-PERFORMANCE BARRIER

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

DUAL - FACED
SEE STD. PLAN C-70.10

TRANSITION SECTION

20' - 0"

VERTICAL BACK
SEE STD. PLAN C-75.20

NOTES

10 1/2" (TYP.)

t ~_b 1'=-+
t
~

c=
-----------------------------------------

c=

~j-c
~

-- enf ~ ~
-

1. PERMANENT INSTALLATION requirements: Embed barrier 3" minimum, install 1/4" Premolded Joint Filler between segments, fill the Connection Blackout with grout, centering
the Rebar Grid in the blackout before adding grout.

2. TEMPORARY INSTALLATION requirement: Place a Rebar Grid in the Connection Blackout


between barrier segments.

3. See Standard Plan C-70.10 for REBAR GRID DETAIL and BARRIER CONNECTION DETAIL.

PLAN

4. This plan is for transitions to precast concrete barriers only.


G)&@- 3 SPACES@ 4" = 1'- 0"

5. When High-Performance Concrete Barrier is specified in the Contract, use the dimensions
given in the H/P row in the DIMENSION TABLE, with a minimum height above roadway of
3' - 6" and a minimum imbedment of 3".

@- 4 SPACES@ 6" = 2'- 0"


8"

2 -12 SPACES

8"

@ 12" = 12'- 0"

REBAR GRID- SEE BARRIER CON


NECTION DETAIL, STD. PLAN C-70.10

2@#5
1J:

C)
-

-+- ------!'---+-- f----+- +-

iT ..+-- ,____,--+-+---+-- f----+

r-rtr I

w b
...J

IIl

a:~

'

!!:!w

a:w
Q!f/)

I I I I I

Ill I I I I I I

1 I

--+--+- +-f----f ____,__ Ti _

!T

f---f--+-+- +- +-

=At-(1 I I I I I

I I I I I l'ltrf

I I I I I I Ii r-t- i-i ! I I I I I I I

+tttt-H-t++-t--t

+~-+-~-+-r~-++rH+~Ft~H-++rr

__l_

TI-T-ri-11-TTinl - - - - - - -irtniTII

~1---3'_-4_"~.1------5'-_0"

__
(TYP.)

(TYP.)

"D"

E~UAL ~PAC~S

_J__j_J__

l.ULUJj_J__L

~.1

J_L_j _

_J_j_,J__J___J_

J_

1-UU J

j_ L

3/4" CHAMFER
(TYP.)
TOP OF
ROADWAY
1J:

C)

iii

...J

J: IIl

1/4" PREMOLDED JOINT FILLERFOR PERMANENT INSTALLATION

2G) (TYP.)

a: ~
w w

w
ii2 fl)

ELEVATION

a:
c(
m

LO

w
::::!: 10
0
z
......
w
' w
N

'

fl)

TOP OF
ROADWAY

z
~

fl)

1J:

WELDED WIRE REINFORCING


SUBSTITUTION OPTION TABLE
REINFORCING
SIZE

WELDED WIRE
REINFORCING

G)

#4

D -20

#4

D -20

#5

D- 31

MARK

C)

iii
J:

...J

IIl

a: ~
!!:! w
w
a: fl)
a:

1J:

'

w
::::!: 10
=
0
...... z
w
' w
N

C)

iii
J:

...J

IIl

a: ~
!!:! w
w
a: fl)
a:

fl)

* WELDED WIRE REINFORCMENTS SHALL

LO

::::!:

bz

=
0

fl)

...J

c(
::J

VARIES

1:

['~ ~

135
HOOK
SEE DIMENSION TABLE

1-

VARIES: 5"
to 1'- 5"

SINGLE-SLOPE CONCRETE
BARRIER (PRECAST)
TRANSITION SECTION
STANDARD PLAN C-75.10-00

#4

21

DIMENSION TABLE

135
HOOK
(TYP.)
VARIES

-I

CONNECTION BLOCKOUT
(TYP.)- SEE NOTE 3

SECTION

REINFORCING STEEL BENDING DIAGRAM


SEE STD. SPEC. 9-07.1(2) FOR
BENDING DIAMETERS

SECTION

aw
p

TOP OF
ROADWAY

......
w
' w
N fl)

TOP OF
ROADWAY

CONFORM TO STANDARD SPECIFICATION


SECTIONS 6-1 0 and 9-07

LO

BARRIER
HEIGHT

SHEET 1 OF 1 SHEET

SEE NOTE5
E

HORIZONTAL
BARS
(QTY.)

STD.

3'- 6"

8"

2'- 0"

3'- 0"

2'-8"

2'- 9"

H/P

4'- 0"

9 1/8"

2'- 2 1/4"

3'- 2 1/4"

3'- 2"

3'- 3"

10

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

NOTES
20'- 0"

.I

I"

10 1/2"

~ ~

~I

~~~

~~9====================================~~

1. PERMANENT INSTALLATION requirements: Embed barrier 3" minimum, install1/4" Premolded Joint Filler between segments, fill the Connection Blackout with grout, centering
the Rebar Grid in the blackout before adding grout.

A~

2. TEMPORARY INSTALLATION requirement: Place a Rebar Grid in the Connection Blackout


between barrier segments.

3. See Standard Plan C-70.10 for REBAR GRID DETAIL and BARRIER CONNECTION DETAIL.

PLAN

4. Vertical Back barrier is used only in the configurations shown in Standard Plans C-85.1 0 and
C-85.20, and when placed against a retaining wall.
5. When High-Performance Concrete Barrier is specified in the Contract, use the dimensions
given in the H/P row in the DIMENSION TABLE, with a minimum height above roadway of
3'- 6", and a minimum embedment of 3".

G)&@- 3 SPACES @4" = 1'- 0"


@- 4 SPACES @6" = 2'- 0"
8"

8"

2 - 12 SPACES
@ 12" =12'- 0"
2@#5

....
~

I'..+-- +---f--+ ---f---+-- .f----+

'

C....

a:~
a::w
a:: en

r-~~-~~-~~-rrrnltir-r :n~Mirrr

_I_ JJI I I I I I I

T-1---r-r---r-r-1-TTrn---r

rr:r I I I I I

w b
...J

Ill

1l.JLUJJ_

i1i

j.

3'- 4"
(TYP.)

r;;r

"D" E~UAL ~PAC~S

j__j_ _j__
5'- 0"
(TYP.)

3/4" CHAMFER (TYP.)


SEE NOTE4

+-1-+-~--t-~~-++~H~~~H--t+~+

-t-t+t+ t-1--t +-+- t---+

!!:!w

REBAR GRID- SEE BARRIER CONNECTION DETAIL, STD. PLAN C-70.10

J _

I I I I I I I:r-t- i-i :I I I I I I I

J...

_J___j_j_j_LU

TTTniTTT
l.UUJJ_LL

TOP OF
ROADWAY

a::

en

b!
......

~
en

...J
()

. LO

~w

:!:I-

= 0
oz

...J

.j

L ___

1/4" PREMOLDED JOINT FILLERFOR PERMANENT INSTALLATION

G)(TYP.)

<
=>

1J:

Ow

-....~
WID
J:<C

. . . w D!l-' w !!:!w
Nen a::w
a:: en

i1i

ELEVATION

* WELDED WIRE

REINFORCING
SUBSTITUTION OPTION TABLE
SECTION

MARK

REINFORCING
SIZE

WELDED WIRE
REINFORCING

CD

#4

D- 20

#4

D- 20

...J
()

#5

D- 31

~
......

a::

en
w

~
en

LO

'

~w

:!:I-

= 0

~
=>

* WELDED WIRE REINFORCMENTS SHALL

~z

1J:

Ow
...J
Wca

~~

,w ww
-Nen
w ii2W
a:: en

0
w

CONFORM TO STANDARD SPECIFICATION


SECTIONS 6-1 0 and 9-07

i1i

CONNECTION BLOCKOUT
(TYP.)- SEE NOTE 3

a::

...J

()

SEE STD. SPEC. 9-07.1{2)


FOR BENDING DIAMETERS

~
......

SECTION

SINGLE-SLOPE CONCRETE
BARRIER (PRECAST)
VERTICAL BACK
STANDARD PLAN C-75.20-00

l l
~~

DIMENSION TABLE
BARRIER
HEIGHT
STD.
H/P

3'- 6"
4'- 0"

A
8"
9 1/8"

B
1'- 6"
1'- 7 1/8"

D
3
4

3'- 0" 2'- 8 1/2" 2'- 8"


3'- 6" 3'- 2 1/2" 3'- 2"

SEENOTE5
H
2'- 9 1/2"
3'- 3 1/2"

J
1'- 2"
1'- 3"

SHEET 1 OF 1 SHEET

HORIZONTAL
BARS
(QTY.)
8
10

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC VIEW

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

NOTES

SINGLE-SLOPE CONCRETE BARRIER (BID ITEM)


10 1/2"
riiiiiL

I
L

----+--

B-

DUAL FACED=---------SEE STANDARD PLA N C-70.10

I~

DIRECTION OF TRAVEL

~
~

+-- ---+

2. TEMPORARY INSTALLATION requirement: Place a Rebar Grid in the Connection Blackout between
barrier segments.

';

11--..

2_

DIRECTION OF TRAVEL

1. PERMANENT INSTALLATION requirements: Embed barrier 3" minimum, install 1/4" Premolded Joint
Filler between segments, fill the Connection Blackout with grout, centering the Rebar Grid in the blackout
before adding grout.

3. See Standard Plan C-70.10 for REBAR GRID DETAIL and BARRIER CONNECTION DETAIL.
1/4" PREMOLDED J OINT FILLER FOR PERMANENT INSTALLATION

4. The Terminal is used only on the trailing end of a barrier, unless otherwise shown in the Contract.

PLAN

@-4 SPACES @6"

5. When High-Performance Concrete Barrier is specified in the Contract, use the dimensions g~v~n in the
H/P row in the DIMENSION TABLE, with a minimum height above roadway of 3'- 6", and a m1n1mum
embedment of 3".

=2'- 0"

1 &@-3 SPACES@4"= 1'-0"

8' -0"

DUAL-FACED
SEE STD. PLAN C-70.10

@)- 5 SPACES
@ 12" = 5'- 0"

1J:

LO

REBAR GRID - SEE BARRIER CONNECTION DETAIL, STD. PLAN C-70.10

~w

CJ

iii

::2:1-

J: III

= 0
oz
.,....w

~
!!!w
It::

-' w
Nen

!t::W
~t::en

i:i

TOP OF
ROADWAY

3/4" CHAMFER
(TYP.)

'j_l

w
....1

TOP OF
ROADWAY

0
LO
~ w N'
::2: 10

=
0
z
.,....
I

w
w

en

TOP OF
ROADWAY

0:::

....1
(.)

~L___

__J

2'- 0"

1/4" PREMOLDED JOINT FILLERFOR PERMANENT INSTALLATION

4' -0"

(TYP.)

12'- 0"

SECTION

SECTION

ELEVATION

* WELDED WIRE

REINFORCING
SUBSTITUTION OPTION TABLE

MARK

REINFORCING STEEL BENDING DIAGRAM


SEE STD. SPEC. 9-07.1(2) FOR

BENDING DIAMETERS

REINFORCING
SIZE

WELDED WIRE
REINFORCING

#4

D-20

#4

D-20

#5

D- 31

CONNECTION BLOCKOUT
(TYP.)- SEE NOTE 3

* WELDED WIRE REINFORCMENTS SHALL

..

CONFORM TO STANDARD SPECIFICATION


SECTIONS 6-10 and 9-07

SINGLE-SLOPE CONCRETE
BARRIER (PRECAST)
TERMINAL
STANDARD PLAN C-75.30-00

VARIES: 7 1/2': I
to1'-4"

en

G)

#4

#4

135"
HOOK

135"
HOOK
(TYP.)

@)
#4

~21

DIMENSION TABLE
BARRIER
HEIGHT

SEE NOTES
F

-'-------

I
I
f--G------1

~G~

STD.
H/P

3'- 6"
4'- 0"

8"
9 1/8"

2'- 0"
2'- 2 1/4"

3
4

2'- 8"
3'- 2"

2'- 9"
3'- 3"

1' -7"
1'- 9"

HORIZONTAL
BARS
(QTY.)
8
10

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC VIEW

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

12' -0" MAX.

0::

>(.)
<(

en

::::i

NOTES

12'- 0" MAX.

1. Reinforcing steel dimensions and clearances are


shown for stationary form construction. When
slipform construction is used, increase reinforcing
steel clearances to the outside surfaces of the
barrier to 2 1/2" and adjust the rebar dimensions
as required.

_L_
A

u.

12'- 0" MAX. BETWEEN DUMMY JOINTS

If

~
---------------------

"'

-r- ' (_

----------------------

--+

-I- - - - - - - - - - - - - - - - - - - - - - -

1t:

(__ DUMMY JOINT TYP.

EXPANSION JOINT

~
c

r-

EXPANSION JOINT

_S

2. When connecting between cast-in-place and precast single-slope barrier, provide a Blackout,
Rebar Grid, and added rebar, as shown in
Standard Plan C-70.1 0.

PLAN
36'- 0" MINIMUM TO 120'- 0" MAXIMUM BETWEEN EXPANSION JOINTS

ct

EXPANSION JOINTSEE DETAIL

G)&@-@ 1'- 6" MAX. SPACING


2@#5

-4-4-+I

4. For Barrier with a 2'- 10" reveal, see Sheet 2.


For High-Performance Barrier with a 3' - 6"
reveal, see Sheet 3.

+ +

---r-----r---r---r--f--r---t----t----t--+-+- I
"~" EQU~L

-~.-~.-~.--+--+--+-

-t--t--t-1- -1-1
SPAC.ES

TOP OF
ROADWAY

------------------------------~~--------------------------------~~--.

3. The actual dimensions will vary as the grades


change and the barrier transitions in height and
width. The dimensions may be interpolated for
intermediate barrier heights.

~-~L-----

--------------------------~L----------

EXPANSION JOINT (TYP.)


2'- 0" MIN. LAP SPLICE (STAGGER SPLICES)

ELEVATION

TOP OF BARRIER
STEEL REINFORCEMENT
SYMMETRICAL ABOUT
PREMOLDED
~
JOINT FILLER
1'- 6"

* WELDED WIRE

1114"PVC

REINFORCING
SUBSTITUTION OPTION TABLE

MARK

REINFORCING
SIZE

WELDED WIRE
REINFORCING

G)
@

#4

D -20

#4

D -20

#5

D- 31

* WELDED WIRE REINFORCMENTS SHALL


CONFORM TO STANDARD SPECIFICATION
SECTIONS 6-10 and 9-07

CONDUIT (TYP.)

t>.

C0~1,l-::

TYPICAL SECTION
11/4" PVC
CONDUIT (TYP.)

II

DUMMY JOINT DETAIL

8 # 8- 36" (TYP.)
PREPARED GRADED BASE
HYPOTHETICAL GRADE SEPARATION

(TYP.)}

@#5

BARRIER TRANSITION DETAIL

PVC CAP (TYP.)

1/2" MIN. EXPANSION


GAP BETWEEN
BARANDCAP

~'\ff ~~FI===l
--Ip

2@#4

ENSURE THAT NO CEMENT CONCRETE ENTERS


THE PVC CONDUIT WHEN POURING

SECTION

W = EPOXYCOATED
REINFORCING STEEL BENDING DIAGRAM
SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAMETERS
9"

2 3/4" R.

to
'

f.v

G)
#4

~21

11~

~21

\'

~F~

EXPANSION JOINT DETAIL

71/4"
11"

(j)

15"

H
ll
@#4
@#4
(j) #4
SEENOTE3

DIMENSION TABLE

SEE NOTE3

BARRIER
HEIGHT

HORIZONTAL
BARS
(QTY.)

3'- 6"

8"

2'- 0"

2'-6"

1'- 8"

4'- 0"
4'- 6"

9 1/8"

2'- 2 1/4"

10 1/4" 2' -41/2"

4
5

3'-0"
3'- 6 1/2"

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
DUAL-FACED
STANDARD PLAN C-80.10-00

s EE NOTE2

1'- 10"
2'- 0"

10
12

ISOMETRIC VIEW

SHEET 1 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

3/4" CHAMFER (TYP.)

3/4" CHAMFER (TYP.)

en
w

en
w

(.)

(.)
<(

:i
~

a.

en

b
.....

~
en

(<)

<(

_J

<(

::J

0
w

("I)

("I)

GRADE SEPARATION
5"MAX.

21 - 0"

2'-0"

SECTION

(<)

::J

TOP OF
ROADWAY

0
w

TOP OF
ROADWAY

_J

SECTION

31 - 6" BARRIER FOR USE WITH A


0" TO 5" MAX. GRADE SEPARATION
(SEE NOTE 3)

3' - 6" BARRIER


SHOWN LEVEL

3/4" CHAMFER (TYP.)


3/4" CHAMFER (TYP.)

:i
:i

b
.....

~
en

b
.....
I

en
w

en

(.)
<(

a.

en

....1

<(

TOP OF
ROADWAY

TOP OF
ROADWAY

::J

~
I

<:t

0
w

LO

__L_---.--

:i

ci
_J

F-.

(.,

~
~ :::!:
~

(.)

GRADE SEPARATION
?"MAX.

:i~

~:::!:
..-

.....

IT~

2'- 4 1/2"

bCxl

SECTION

4'- 6" BARRIER FOR USE WITH A


GREATER THAN 7" TO 10" MAX.
GRADE SEPARATION
(SEE NOTE 3)

4 1 - 0" BARRIER FOR USE WITH A


GREATER THAN 5" TO 7" MAX.
GRADE SEPARATION
(SEE NOTE 3)

.....

_f

TOP OF
ROADWAY

GRADE SEPARATION
10" MAX.

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
DUAL-FACED
STANDARD PLAN C-80.10-00
SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

STANDARD MOUNTING HEIGHT

Pasco Bakotich Ill


.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

3/4" CHAMFER {TYP.)


3/4" CHAMFER {TYP.)

3/4" CHAMFER {TYP.)

()
<(

a.

en

<(

0
w
co

TOP OF
ROADWAY

~
Co

en

c.,

_J

_J

:::J

()
<(

a.

<(

:::J

SECTION

4'- 0" BARRIER


SHOWN LEVEL

2- 2 1/4"

SECTION

4' - 0" BARRIER FOR USE WITH A


0" TO 3" MAX. GRADE SEPARATION
{SEE NOTE 3)

_J

:::J

Co
~

0
w

TOP OF
ROADWAY

co

TOP OF
TOP OF
ROADWAY

ROADWAY

GRADE SEPARATION
3"MAX.

en

!1-\;::=:::;-:l.=::::;::::=='==---

~~I
~ ~ ~1 .

<(

0
w
co

TOP OF
ROADWAY

en

en
w

en
w

!)~ ~~
..._

1.

2-,~ .1

SECTION

!]

GRADE SEPARATION
6"MAX.

4' - 6" BARRIER FOR USE WITH A


GREATER THAN 3" TO 6" MAX.
GRADE SEPARATION
{SEE NOTE 3)

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
DUAL-FACED
STANDARD PLAN C-80.10-00
SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

HIGH-PERFORMANCE BARRIER

Pasco Bakotich Ill


.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

36'- 0" MINIMUM TO 120'- 0" MAXIMUM BETWEEN EXPANSION JOINTS

NOTES

DUMMY JOINT SEE NOTE 2

. - DIRECTION OF TRAVEL

1. The Terminal is used only on the trailing end of a barrier, unless otherwise shown in the Contract.
2. See Standard Plan C-80.10, Sheet 1, for EXPANSION JOINT and DUMMY JOINT details.
3. When High-Performance Concrete Barrier is specified in the Contract, use the dimensions
given in the H/P row in the DIMENSION TABLE, with a minimum height above roadway of 3'- 6",
and a minimum embedment of 3".

. - DIRECTION OF TRAVEL

EXPANSION JOINT SEE NOTE2

PLAN

3/4" CHAMFER (TYP.)


SINGLE SLOPE CONCRETE BARRIER (BID ITEM)
10'- 0" MIN. TO 12'- 0" MAX.

11/2" CLR.

SEE STANDARD PLAN C-80.10

TOP OF

3/4" CHAMFER

RO~WAY\\
FIELD BEND
#5 BARS

. [ uYP.J
(

(")

~w

:::!!:1--

= 0

~z

,w

-C\ICJ)
w
TOP OF
ROADWAY

TOP OF
ROADWAY

SECTION

1'- 8"

1~

(TYP.)

~1

4 -5SPACES@ 1'-6"=7'-6"

~:-~
SECTION

ELEVATION
3/4" CHAMFER (TYP.)

* WELDED WIRE REINFORCING

SUBSTITUTION OPTION TABLE

MARK

REINFORCING
SIZE

WELDED WIRE
REINFORCING

#4

D -20

#4

D -20

#5

D- 31

CD

(")

~w

:::!!:1-= 0
oz

..... w
-'
w
C\ICJ)

* WELDED WIRE REINFORCMENTS SHALL


CONFORM TO STANDARD SPECIFICATION
SECTIONS 6-10 and 9-07

~1

REINFORCING STEEL BENDING DIAGRAM

SECTION

SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAMETERS

9"

2 3/4" R
(o

'

"'

CD
#4

~21

VARIEs.
1

~F~

21

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
Ti:RMINAL
STANDARD PLAN C-80.20-00

r-

11 ~ ~ ([jj21
4

~F~

DIMENSION TABLE
BARRIER
HEIGHT
STD.
H/P

3'- 6"
4'- 0"

A
8"
91/8"

B
2'- 0"
2'- 2 1/4"

D
3
4

E
2'- 6"
3'- 0"

SEE NOTE 3
F
1'- 8"
1'- 10"

HORIZONTAL
BARS
(QTY.}
8
10

SHEET 1 OF 1 SHEET

ISOMETRIC VIEW

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

12' - 0"

12' - 0"

12' - 0"

- - - - - - - - - - - - - - - - - - - - - - t---- - - - - - - - - - - - - - - - - - - - t-- - - - - - - - - - - - - - - - - - - - -

( _ EXPANSION JOINT

NOTES

~2

2. See Standard Plan C-80.10, Sheet 1, for EXPANSION JOINT

~_E/2

(_ DUMMY JOINT

( _ DUMMY JOINT

1. The Transition Section is used in the configurations shown in


Standard Plans C-85.1 0 and C-85.11.

and DUMMY JOINT details. Modify rebar on wider end as


shown in EXPANSION JOINT MODIFICATION.

EXPANSION JOINT

PLAN

DUAL-FACED
SEE STD. PLAN

v ,-

C-80.1~A

VERTICAL BACK

TRANSITION SECTION - 36' - 0"

G)&-@ 1'- 6"

SPACING

'-----------------------""''----'""'----=----------------------------1
MAX.

EXPANSION JOINT
- NOTE2

3. Reinforcing steel dimensions and clearances are shown for sta


tionary form construction. When slip-form construction is used,
increase reinforcing steel clearances to the outside surfaces of
the barrier to 2 1/2" and adjust steel dimensions as required.
4. When High-Performance Concrete Barrier is specified in the
Contract, use the dimensions given in the H/P row in the
DIMENSION TABLE, with a minimum height above roadway
of 3'- 6" and a minimum embedment of 3".

DUMMY JOINT {TYP.)

ct
STEEL REINFORCEMENT
.. ~ SYMMETRICAL ABOUTct
4 112
,___.

TOP OF
ROADWAY
-"----- -7~--------------------------- _,,._----------------------------- -'"----------------------------

EXPANSION JOINT

1' -31/4"
1'-7"

-_jL.---------'

@1'-11"

_j

ELEVATION

I #4 I

3/4" CHAMFER (TYP.)

1 1/2" CLR.
'<!'

bz

REINFORCING
SIZE

WELDED WIRE
REINFORCING

#4
#4
#5

D -20
D -20
D- 31

G)

.-w
W
('o.jen

en

iii

::::l

J:

...I

SECTION

J: Ill
0:: ~

EXPANSION JOINT MODIFICATION


SEE NOTE2

!!:! w
0:: w
0:: en

c(

3/4" CHAMFER (TYP.)

~1

CONFORM TO STANDARD SPECIFICATION


SECTIONS 6-10 and 9-07

IC)

<(

TOP OF ROADWAY

* WELDED WIRE REINFORCMENTS SHALL

...I

#4
@#4
REINFORCING STEEL
BENDING DIAGRAM

<(

c.

:::!:o

WELDED WIRE REINFORCING


SUBSTITUTION OPTION TABLE

en

(.)

:Zw
-1-

MARK

~goHOOK

'<!'

:Zw
-1-

SECTION

:::!:o

TRANSITION SECTION FROM DUAL-FACED TO


2 x VERTICAL BACK

bz

.-w
W
('o.jen

TOP OF ROADWAY

REINFORCING STEEL BENDING DIAGRAM


SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAMETERS
VARIES:5"

;------..1 to 1' -1"


4

~21

I
I

~ 21

SECTION

\~

L
E

VARIES

BARRIER
HEIGHT

.j

STD.
H/P

3'- 6"
4'- 0"

3
8"
2'- 0"
2'- 8"
9 1/8" 2'- 2 1/4" 2' -10 1/4" 4

ISOMETRIC VIEW

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
TRANSITION SECTION
STANDARD PLAN C-80.30-00

SEENOTE4

DIMENSION TABLE

11
1.

TRANSITION SECTION FROM DUAL-FACED TO


2 x VERTICAL BACK

E
2'- 6"

3'- 0"

HORIZONTAL
BARS
(QTY.)
8

10

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

NOTES

Cl

0::

12'- 0" MAX.

12'- 0" MAX. BETWEEN DUMMY JOINTS

l~r

I.

LL

<(
(J)

::::i

~E~
2.__

:;..:

Ill

Cl

12'- 0" MAX.

2.__

EXPANSION JOINT

.I

I.
I~

~_tl

1. The Vertical Back barrier is used only in the configurations


shown in Standard Plans C-85.10 and C-85.11, and when
placed against a retaining wall.

.I

Ill

DUMMY JOINT
(TYP.)- SEE NOTE 2

EXPANSION JOINT

2. See Standard Plan C-80.10, Sheet 1, for EXPANSION


JOINT and DUMMY JOINT details. Modify rebar as shown
in EXPANSION JOINT MODIFICATION.

=s

3. Reinforcing steel dimensions and clearances are shown for

PLAN

stationary form construction. When slip-form construction


is used, increase reinforcing steel clearances to the outside
surfaces of the barrier to 2 1/2" and adjust steel dimensions
as required.

36'- 0" MINIMUM TO 120'- 0" MAXIMUM BETWEEN EXPANSION JOINTS

G)&

2 -@ 1' 6" MAX. SPACING


EXPANSION JOINT
-SEE NOTE2

TOP OF
ROADWAY

4. When High-Performance Concrete Barrier is specified in


the Contract, use the dimensions given in the H/P row in
the DIMENSION TABLE, with a minimum height above
roadway of 3'- 6" and a minimum embedment of 3".

41/2"

6"

(Y) 8"
@10"

5 1/2"
2'- 0" MIN. LAP SPLICE (STAGGER SPLICES)

~goHOOK

ELEVATION
6 1/2"

(8)#4
(Y) #4
@#4

REINFORCING STEEL
BENDING DIAGRAM
CONC. CAP
-SEE NOTE 1

3/4" CHAMFER
(TYP.)

SECTION

* WELDED WIRE REINFORCING

EXPANSION JOINT MODIFICATION

SUBSTITUTION OPTION TABLE

MARK

REINFORCING
SIZE

WELDED WIRE
REINFORCING

CD

#4

D -20

#4

D -20

#5

D- 31

SEE NOTE2
-.:I"

~w

:::2:1-

= 0
oz

... w
-'
w
N(J)
TOP OF
ROADWAY

* WELDED WIRE REINFORCMENTS SHALL


CONFORM TO STANDARD SPECIFICATION
SECTIONS 6-1 0 and 9-07

SECTION

REINFORCING STEEL BENDING DIAGRAM

SINGLE-SLOPE CONCRETE
BARRIER (CAST-IN-PLACE)
VERTICAL BACK
STANDARD PLAN C-80.40-00

SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAMETERS

7 1/2"

-~~

21/4" R

(j)
~

#4

~21

~21

1~
~F~

DIMENSION TABLE
BARRIER
HEIGHT
STD.
H/P

3'- 6"
4'- 0"

A
8"

9 1/8"

B
1'4"
1'- 5 1/8"

D
3
4

E
2'-6"
3'- 0"

SEENOTE4
F

1'-01/4"
1'- 1 1/2"

HORIZONTAL
BARS
(QTY.)

8
10

SHEET 1 OF 1 SHEET

ISOMETRIC VIEW

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

10' - 0" TRANSITION

~ i/ t.-1'- 0"

MULTIPLE SURFACES TO SINGLE SLOPE

::::~_C

DUMMY JOINT~

'
'

This plan is for transitions to Precast Concrete Barrier Type 2 only.


See contract for transitions to other barrier shapes and bridge rails.

~~v1'-0"
llj~;v

'
'
------------------'-------

NOTE

24' - 0" HEIGHT TRANSITION

~
------------------

[,0'1 I

PL-T-----tl

"'

3/4"
CHAMFER
(TYP.)

~
~

' - 0__________________
"
~1-------------------12__
~.1 (__ DUMMY JOINT
/e)
PLAN

CONCRETE BARRIER TYPE 2

6"

SINGLE-SLOPE CONCRETE BARRIER (BID ITEM)

24' - 0" HEIGHT TRANSITION

SEE STANDARD PLAN C-80.10

1'- 0"

1'- 6"

G)#4&@#4
@ 1'- 6" SPACING

2@#5

DUMMY JOINT

7 #4

SECTION

ELEVATION
REINFORCING STEEL BENDING DIAGRAM
5 1/2"

4"

~rVARIES

9r

5 TO 11

3/4"
CHAMFER
(TYP.)

&>

1 1/2" CLR.

I \}6"
I/\,VARIES
u

8 5/8"

MINi_

'

VARIES
VARIES
35 TO 11 o: \ ~: ~ 3" TO

3/4"
CHAMFER
(TYP.)

1'-8"

2. All bends are 2" radius.


1'-7"T01'-8"

I>

DUMMY JOINT

ISOMETRIC VIEW
@#4
2'- 0"

SECTION
1. Field bend as required
in transition.

'

@#4

NOTES

.. :I>

&>

79 (TYP.)SEE NOTE 1

---+-...-....

___l_10" TO 6"

1-

CLR.

2'- 0"

SECTION

CLR.

CONCRETE BARRIER
TRANSITION
TYPE 2 TO SINGLE-SLOPE
STANDARD PLAN C-80.50-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

DUAL-FACED

TRANSITION SECTION
LENGTH VARIES PER BARRIER TYPE

VERTICAL BACK
LENGTH VARIES PER BARRIER TYPE AND TAPER RATE

SEE CONTRACT FOR TAPER RATE

DUAL-FACED
LENGTH VARIES PER CONTRACT

CONCRETE CAP

L --

I
~------

1----

--=-@
I

--I----- -~------

Jnl

PLAN

_ll

;;, :.:-::-;_-=---

CONCRETE CAP

(CAST-IN-PLACE SHOWN)

NOTES

STEEL WELDED WIRE FABRICCOMPLY WITH STANDARD SPEC 9-07.7


6 W2.1 X W2.1 (8
6 W2.9 X W2.9 (6
X 6 W4.0 X W4.0 (4
4 X 4 W1.4 X W1.4 (10
4 X 4 W2.1 X W2.1 (8
4 X 4 W2.9 X W2.9 (6
6
6
6

X
X

1. Use the barrier type, precast or cast-in-place, as specified in the Contract.

GAGE)
GAGE)
GAGE)
GAGE)
GAGE)
GAGE)

6' -0"

SINGLE-SLOPE
CONCRETE BARRIER
DUAL-FACED

2. For Single-Slope Concrete Barrier details, see Standard


Plan series C-70's (precast) or C-BO's (cast-in-place).

11/2" CLEARANCE ON ALL SURFACES


CONCRETE CAP

CONCRETE CAP

SECTION

SELECT BORROW INCLUDE HAUL

VARIES
SLOPE TO DRAIN ~0
to 5'- 0"
COMMERCIAL
CONCRETE

STEEL WELDED
WIRE FABRIC

c.,

3/4" CHAMFER (TYP.)

I
SINGLE-SLOPE CONCRETE
BARRIER: DUAL-FACED
3/8" PREMOLDED
JOINT FILLER (TYP.)
SINGLE-SLOPE CONCRETE
BARRIER: VERTICAL BACK
(TYP.)

TOP OF
ROADWAY

ISOMETRIC VIEW
(CAST-IN-PLACE SHOWN)

SELECT BORROW INCLUDE HAUL

SECTION

SINGLE-SLOPE CONCRETE
BARRIER PLACEMENT
(SPLIT)
STANDARD PLAN C-85.10-00

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

DUAL-FACED

TRANSITION SECTION
LENGTH VARIES PER BARRIER TYPE

VERTICAL BACK
LENGTH VARIES PER CONTRACT

SEE CONTRACT FOR TAPER RATE

CONCRETE CAP
BRIDGE COLUMN

PLAN
(CAST-IN-PLACE SHOWN)

NOTES
1. Use the barrier type, precast or cast-in-place, as specified in the Contract.
3" EXPANDED POLYSTYRENE
AROUND COLUMN (TYP.)

2. For Single-Slope Concrete Barrier details, see Standard


Plan series C-70's (precast) or C-SO's (cast-in-place).

BRIDGE COLUMN

,..t>.
..
SINGLE-SLOPE CONCRETE
BARRIER: VERTICAL BACK
(TYP.)

.'
,.

STEEL WELDED WIRE FABRIC COMPLY WITH STANDARD SPEC 9-07.7

SLOPE TO DRAIN
COMMERCIAL
CONCRETE

VARIES

_
c.,

TOP OF
ROADWAY

6 x 6 W2.1 x W2.1 (8 GAGE)


6 x 6 W2.9 x W2.9 (6 GAGE)
6 X 6 W4.0 X W4.0 (4 GAGE)
4 X 4 W1.4 X W1.4 (10 GAGE)
4 X 4 W2.1 X W2.1 (8 GAGE)
4 X 4 W2.9 X W2.9 (6 GAGE)

CONCRETE CAP
SELECT BORROW INCLUDE HAUL

1 1/2" CLEARANCE ON ALL SURFACES

SECTION

3/8" PREMOLDED
JOINT FILLER (TYP.)
SINGLE-SLOPE CONCRETE
BARRIER: VERTICAL BACK
(TYP.)

TOP OF
ROADWAY

ISOMETRIC VIEW

SECTION

(CAST-IN-PLACE SHOWN)

SINGLE-SLOPE CONCRETE
BARRIER PLACEMENT

(WRAP)
STANDARD PLAN C-85.11-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

04118112
DATE

. . . Washington State Department of Transportation

21'- 6"
10'- 0"

"'~;~"

~~

_j_

l 1/'T----t--1-:+------~

:
Z(+'
T~
-------/:--. !! ..-. :/~--:--------I

l__

./

I
\

.1'-0" ___/- /

:~:

/A.

II

/._

3/4" CHAMFER
(TYP.)

~m~

<(

a.
w

'

4 6

v_-:----

6 3
: - - - - -_'-__"_ _ _

--__..

--p-=--g~~-:~E

en

~
::::!:
.....
6'- 3"

NOTE 2

1/2" DRAIN HOLE

ANCHOR BOLT (TYP.) - SEE


DETAIL, STANDARD PLAN C-Bb

io
N

CONDUIT COUPLING SEE NOTE4

STEEL LIGHT STANDARD SEE STANDARD PLAN J-28.60

'

~t-

10'- 0"

9" 1 9"

SEE ANCHOR BOLT~


LAYOUT DETAIL
\

B/2t

GROUNDING CONDUCTOR - ROUTE TO


GROUNDING STUD (SEE NOTE 3)

:Z
~

~
::::!:

.....

&,

,.,

1:2

en
w

(.)

cten

....1
<(

::J

0
w

(.!)

Ln

I-

::c

w
jjj ....1
::c m
(.!)

0:::

w w
0:: w
0:::

en

<(

<(

a.

~
::::!:
.....

:Z
~

en

b
.....

~
::::!:

@# 5
(TYP.)

&,

,.,

1:2

en
w

I-

<(

jjj
::c m

(.)

a.

en

....1
<(

::J

0
w

(.!)

Ln

::c
(.!)

....1

0:::

0:::

en

w w
0:: w
<(

LL

21'- 6"
CD#4AND@#4

CAP

@# 5 (TYP.)
CLR.

1'-0"

'

5 SPACES @
1'- 0"
5'- 0"

SECTION

@# 5 (TYP.)

3/4" CHAMFER
(TYP.)

EXPANSION JOINT
WITH 3/4" PREMOLDED
JOINT FILLER (TYP.)

SEE NOTE 3

SECTION

NOTES
TOP OF
ROADWAY

1. When connecting between cast-in-place and precast Single-Slope Barrier, provide


a Connection Blackout and Rebar Grid as shown on Standard Plan C-1 3.
2. See the Contract Plans for conduit placement.

2" CLR.
(TYP.)

1" DIAM. ANCHOR


BOLT (TYP.)

3. Grounding Conductor shall be non-insulated #4 AWG stranded copper, provide


3' - 0" min. slack. Clamp steel reinforcing bar with connector suitable for use .--..,.....-----,
embedded in concrete.
~,.
ii .
,..,~;:,,_,
4.

SEE NOTE 2

5@# 5

9'- 0"
PLAN VIEW

ELEVATION
ALL DIMENSIONS ARE OUT TO OUT
ALL BENDS ARE 2" RADIUS
VARIES 5 1/2"
TO 21 1/2"

I='
::c

r-

G)

jjj

(.!)

jjj

::c
w

'---._

::c
w

I='
::c

en

0:: +

11
(TYP.)

0:::

<(

m
(:::!

~'-----

en

0:: +

---

0:::

;a
11
(TYP.)

(:::!

.....

G) F+26

1--

1/2"

@VARIES (B-4 1/4") TO (B+3 3/4")

G) VARIES

LOCATION

(C-10 3/4") TO (C-5")

~~~~::)

5. This plan shall be used for 40' and 50'


Light Standards with 16' max. length
double mast arms.

\!Oirh

~~@5~~

.u..I!::!Ql
!!!l!!fil;:!'o

(!)

"(~S:Cflw

~~~~~

6. Concrete shall be Class 4000.

SIZE

QUANTITY

~~~~8
ii'~ffi"'""

CD

BARRIER - TOP VERTICAL

#4

28

~~~~~
2;:;2.::1-r::

BARRIER - BOTTOM VERTICAL

#4

12

!il~~~~

G)

FND. & BARRIER - VERTICAL

#4

16

BARRIER - HORIZONTAL

# 5

"Q"

FOUNDATION

# 5

FOUNDATION

# 5

32

______::::: -

@ F+2 1/2"

CD

ANCHOR BOLT LAYOUT DETAIL

LIST

g2:!?l

~(JQ~)..

MARK
NO.

0:::

(.!)

0:::

BAR

a~n~~m
5
(!)~~~~
~-fj:::l-2:
.. ;!~iii~

Install Conduit Coupling flush with top of


foundation. Do not glue PVC stubout.

~"(LIJ"'t~

SINGLE-SLOPE CONCRETE
BARRIER LIGHT STANDARD
FOUNDATION
STANDARD PLAN C-85.14-00

TABLE
GRADE
SEPARATION
0 TO 5"

SEE NOTE 1

BARRIER
HEIGHT

3'- 6"

8"

2'- 0"

3'- 4"

3" MIN.

1'- 2"

12

UP TO 7"

4'- 0"

9 1/8" 2'- 2 1/4"

3'- 6 1/4"

7" MIN.

10"

12

UP TO 10"

4'- 6"

10 1/4" 2'- 4 1/2"

3'-8 1/2" 10" MIN.

7"

14

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

ISOMETRIC VIEW

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

21'- 6"
10'- 0"

~~

_l

3/4" CHAMFER
(TYP.)

./

B/2~i-

-----

..rl

-,/~-----=<+:- ~ ~-----t-~r=_=
__::_=__::_=__:::_=li ~:
1
~ H ~L==~=1======1
.1'-0"--"' /

II

/_

mj

"''

a.

"'
""

en

::::!:

IJ:

::::!:
b

~
en

w ....1
J: ID

"'"

::J

(!)

Ln

en

(!)

(..)

0::

....1
<(

Ln

1 1/2" CLR.

<(

1/2" DRAIN HOLE


3/4" CHAMFER (TYP.)

1 1/2"
CLR.

CONDUIT COUPLING SEE NOTE 5

ANCHOR BOLT (TYP.) - SEE


DETAIL, STANDARD PLAN C-Sb

1 1/2" CLR.

~~L---------~1~==J\kltk/~--~~~-r-------

STEEL LIGHT STANDARD


- SEE STANDARD PLAN J-28.60

'

2'- 0"

10'- 0"

9" 19"

SEE ANCHOR BOLT~


LAYOUT DETAIL
\

GROUNDING CONDUCTOR - ROUTE TO


GROUNDING STUD (SEE NOTE 3)

<(

a.

w w

::::!:

0::

Ln

w
ii: en

0
w

;a

Ln

en
w

"'
""

(!)

:Z zw

~ ::!!:
c
Ln w

....'

ID

::!!:

CAP

21'- 6"

@# 5 (TYP.)

2 1/2" CLR.

1-

SECTION
3/4" CHAMFER
(TYP.)

@# 5 (TYP.)
I

SEE NOTE 3

5'- 0"

I
NOTES
TOP OF
ROADWAY

SECTION

CONSTR. JOINT
WI ROUGHENED
SURFACE

1. This Barrier/Foundation combination has been designed in accordance with AASHTO LRFD Test Level 4 requirements. The horizontal
vehicle impact force at the top of the barrier is taken at 54 kips for Strength and Extreme Limit States, and 10 kips for footing stability
(overturning and sliding) in the Service Limit State.
2. When connecting between cast-in-place and precast Single-Slope Barrier, provide a Connection Blackout and Rebar Grid as
shown on Standard Plan C-13.

EXPANSION JOINT
WI 3/4" PREMOLDED
JOINT FILLER (TYP.)

3. Grounding conductor shall be non-insulated #4 AWG stranded copper, provide a 3' - 0" min. slack. Clamp steel
reinforcing bar with connector suitable for use embedded in concrete.
4. See the Contract Plans for conduit placement.

3" (TYP.)
5@# 5

9'- 0"

6 3/8"

ELEVATION
ALL DIMENSIONS ARE OUT TO OUT
ALL BENDS ARE 2" RADIUS
VARIES 5 1/2"
TO 21 1/2"

I='

MARK
NO.

r-

G)

J:

0::

w
w

J:

(!)

(!)

'---._

J:

a.

ii: +

11
TYP.

0::

;a

---

11
TYP.

0::
ID

~'----

a.

ii: +

<(

(:::!

CD

I='
@

J:

0::

BAR

(:::!

.....

SIZE

QUANTITY

BARRIER - TOP VERTICAL

#4

28

BARRIER - BOTTOM VERTICAL

#4

12

G)
@

FND. & BARRIER - VERTICAL

#4

16

BARRIER - HORIZONTAL

# 5

"Q"

FOUNDATION

# 5

FOUNDATION

# 5

32

G) F+26

1--

1/2"

@VARIES (B-4 1/4") TO (B+3 3/4")

G) VARIES

(C-10 3/4") TO (C-5")

6.
1" DIAM. ANCHOR
BOLT (TYP.)

This plan shall be used for 40' and 50' Light


Standards with 16' max. length double mast arms.
7.

Concrete shall be Class 4000.

SINGLE-SLOPE
CONCRETE BARRIER
(42 )

SEE NOTE 4
PLAN VIEW

ANCHOR BOLT LAYOUT DETAIL

LIGHT STANDARD FOUNDATION

STANDARD PLAN C-85.15-00

______::::: -

@ F+2 1/2"

CD

---1

LIST

LOCATION

5. Install Conduit Coupling flush with top of foundation.


Do not glue PVC stubout.

6 3/8"

SEE NOTE 2

TABLE

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

GRADE
SEPARATION

BARRIER
HEIGHT

0 TO 3"

4'- 0"

9 1/8"

2'- 2 1/4"

3'- 6 1/4"

VARIE S 6"TO 9"

1'-2"

14

UP TO 6" MAX.

4'- 6"

10 1/4" 2'- 4 1/2"

3'- 8 1/2"

VARIE S6"T09"

11"

14

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

ISOMETRIC VIEW

SINGLE-SLOPE CONCRETE BARRIER

SIGN BRIDGE

24'- 0" TAPER

1'- 6"

12'- 0" TYP.

B/2t

SINGLE-SLOPE CONCRETE BARRIER

END POST SPACING 'W'

:,____,
_W_12----11

1'- 6"

24'- 0" TAPER

~tt__[::~__:-=-_:_=__: _=__: _=__=_=_=_:=_=_:=_f===========l~~~~~====;//"1:""""'~,,~""~")~~-E


~:~o\11/_T>-_";3'-:0'~'--~=--~=-_=_=__==__=__=_====__=_=J===========JI
-W,~ f- ~) .y_.
------------- L
r----------------

(_

-('

',,

'

'

"' .. j

NOTES
PLAN

1.

When connecting between Cast-in-Place and Precast Single-Slope


Barrier, provide a Connection Blackout and Rebar Grid as shown in
Standard Plan C-13.

2.

Grounding Conductor shall be non-insulated #4 AWG stranded copper,


provide a 3' - 0" slack. Clamp steel reinforcing bar with connector
suitable for use embeded in concrete.

3. Install Conduit Coupling flush with top of Barrier. Do not glue PVC stubout.
4. Concrete shall be Class 4000, unless otherwise noted.

24'- 0"

SEE STD. PLAN G-70.10 FOR


SIGN BRIDGE DETAILS

END POST SPACING 'W'

G)# 4 AND 2 # 4-15 SPACES@

1'-6"= 22'-6"

24'- 0"

G)# 4 AND 2 # 4 -15 SPACES @

1'- 6" = 22'- 6"


3/4"
CHAMFER
(TYP.)

EXPANSION JOINT WITH 3/4"


PREMOLDED JOINT FILLER (TYP.)

EXPANSION JOINT WITH 3/4"


PREMOLDED JOINT FILLER (TYP.)

TOP OF
ROADWAY

2 1/2" CLR. MIN.

1-:HAFT REINFORCEMENT

t;'

'-------"'"-------'--'""----------""'----------1~
-NOT
@# 4,@# 4 AND(j)# 4
~

.-

SHOWN FOR CLARITY

@ 6" MAX. SPACING

t> .

SEE SECTION "C", SHEET 2


FOR GROUNDING
CONDUCTOR DETAILS
(SEE NOTE 2)

DUMMY JOINT
DIMENSIONS "W' AND

nzn

SIGN BRIDGE
SPAN LENGTH

60'0R LESS

4'- 0"

11'- 6"

61'TO 91'

5'- 0"

13'- 6"

91'TO 120'

6'- 0"

15'- 0"

121'TO 150'

7'- 0"

16'- 6"

SHAFT DEPTH "Z" IS BASED ON ALLOWABLE LATERAL BEARING PRESSURE IN


EXCESS OF 1500 PSF.

3'- 0" DIAM.


SHAFT

SINGLE-SLOPE
CONCRETE BARRIER
SIGN BRIDGE FOUNDATION
STANDARD PLAN C-85.16-00

SHAFT REINFORCEMENT

ELEVATION

SHEET 1 OF 2 SHEETS
SEE NOTE 1

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

ISOMETRIC VIEW

3'- 0"

ANCHOR BOLT - 1" DIAM. x (BARRIER HEIGHT + 4'- 2")


LONG, GALV., THREADED ROD OR STUD BAR WITH
FOUR HEAVY HEX NUTS AND FOUR WASHERS (TYP.)

SIGN BRIDGE END POST


(SEE STD. PLAN G-70.10)
GROUNDING CONDUCTOR ROUTE TO GROUNDING STUD
(SEE NOTE 2)

CONDUIT COUPLING - SEE NOTE 3


3/4"
CHAMFER
(TYP.)

1 1/2" (/)

CLR.

:il G)# 5 -~
~

(/)

(TYP.)

...J
<(

::::>

0
w

1 1/2" (/)
w
CLR. (..)

C!>w

:il

jjj
J: <(
0::: 1-

w w
- w
~ (/)

ffi

(TYP.)

3/4" CHAMFER
(TYP.)

3'- 0"

G)# 5
(TYP.)

(/)

...J
<(

::::>

;a

TABLE
GRADE
SEPARATION

@#4

BARRIER
HEIGHT

0 TO 5"

3'- 6"

8"

2'- 0"

4'- 4"

3" MIN.

10

UP TO 7"

4'- 0"

9 1/8" 2'- 2 1/4"

4'- 6 1/4"

7" MIN.

12

UP TO 10"

4'- 6"

10 1/4" 2'- 4 1/2"

4'- 8 1/2" 10" MIN.

14

J:

(!)

jjj ...J
J: Ill

0:::

0
w

w w
0:: w

;a

0:::

~
~
~

A ADD TWO (4) # 5 BARS, EQUALLY SPACED,


'0" AT THE TQ):s' OF THE FOUNDATION BARRIER

1J:

1-

C!>w

:il

ffi

@# 5
(TYP.)

...J

:$

......

;a

AOADWAY

(/)

w
-w w

@ ~ (/)

TOP OF

jjj
J: <(
0::: 1-

NOTCH PLATE AS REQUIRED TO CLEAR THE


SHAFT REINFORCEMENT WHEN 'W' = 4'- 0"
1 1/2" SNIP (TYP.)
1 1/16" DIAM. HOLE (TYP.)
1'- 3" DIAM. HOLE

c ._______.______

"

LOCATION

60'0R LESS

LENGTH

61'TO 91'

91'TO 120' 121'TO 150'

QTY.

SIZE

QTY.

SIZE

QTY.

SIZE

QTY.

BARRIER - TOP VERTICAL

#4

32

#4

32

#4

32

#4

32

BARRIER - BOTTOM VERTICAL

#4

28

#4

28

#4

28

#4

28

<J)

BARRIER - HORIZONTAL

# 5
# 5

0
0

# 5

BARRIER - HORIZONTAL

0
0

# 5

0
0

# 5

BARRIER - TOP VERTICAL

#4

14

#4

16

#4

18

#4

20

CAP & BARRIER - VERTICAL

#4

14

#4

16

#4

18

#4

20

CAP - TOP TRANSVERSE

#4

14

#4

16

#4

18

#4

20

CAP - HORIZONTAL

# 5

12

# 5

12

# 5

12

# 5

12

SHAFT - VERTICAL

# 9

12

# 11

15

# 11

18

# 11

24

@)

SHAFT - SPIRAL
SEE TABLE, THIS SHEET,
COLUMN "Q"

w en

0:::

0:: +

11"
(TYP.)

jjj
J:

0:::

;a0:::

~
~

-~

I~"

CD

0
0

1~

1 1 .I
VARIES

1'- 0"

');. ~'!(>
~

1-

@9 1/2"
@4'- 3 1/2"

L@VARI~S

(B - 4 1/4")
TO (B + 22")

@c -5"

21"

STEEL PLATE
(SEE DETAIL)

1i:'

1-

J:
J: 10

1-

w
w

4 EQUAL SPACES

ga. z

J:

w8
...Jo

~ ::!!
:20
=
co
~

~(/)
(/)
~(..)

-N~
w

J: J:

:5:
a.

<(

0
0

...J

1-

(/)

a.

a.z
1-

u.

a: Iii
...J

(g)# 9 OR

1f 11

(/)

(TYP.)

::!!
=11:0
(..)

'<I'

c - 5"

LAP SPLICE
DETAIL

Q.

SINGLE-SLOPE
CONCRETE BARRIER
SIGN BRIDGE FOUNDATION
STANDARD PLAN C-85.16-00

CLR.

l~"

ALL BENDS ARE 2" RADIUS


ALL DIMENSIONS ARE OUT TO

8" (TYP.)

~5
wo
0(..)

;.,'

0:::
J: ::::>

24@# 11
BUNDLED

tl:l::S

Ill

1- 11-

18@# 11

VERTICAL SHAFT STEEL LAYOUT

Ill'<!'

I=

-'

15@# 11

(J)a.

<(

I-'-

21"

STEEL PLATE DETAIL

@)~

II

#4

((;
,, ~

C:!

111"
(TYP.)

<(

C:!

en

0:: +

# 5

1~

#4

(!)

0:::
Ill

1~

#4

~
J:

r-

jjj
J:

# 5

5 3/4"
TO 2'- 9 1/2"
@2'- 9 1/2"

~
J:

# 5

IF JOINING TWO SPIRALS,


SEE LAP SPLICE DETAIL

CD VARIES

(!)

1~

~5
P.)

SIZE

#4

A36 STEEL PLATE, 5/8"

0#4

CD

@#4

LIST
SPAN

MARK
NO.

CLR.

SECTION

BAR

1'- 9" BOLT CIRCLE

'"'1------c-------1I~

@# 4

SECTION

___.+--"-----__L_

SECTION

au

SHEET 2 OF 2 SHEETS

CONSTRUCTION JOINT WITH

~ ROUGHENED SURFACE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

SINGLE-SLOPE CONCRETE BARRIER


12'- 0"

12'- 0"
DUMMY JOINT

12'- 0"

_I

7_

--........

,-------------------------------- ---------------

~
/

( _ EXPANSION JOINT
DUMMY JOINT

BAR

NOTES

lu

1. When connecting between


Cast-in-Place and Precast
Single-Slope Barrier, provide
a Connection Blockout and
Rebar Grid as shown in
Standard Plan C-1.3
2. All concrete shall be class 4000.

LOCATION

SIZE

QTY.

CD

BARRIER - TOP VERTICAL

# 4

24

@
G)

BARRIER - BOTTOM VERTICAL

# 4

24

BARRIER - HORIZONTAL

# 5

SEE DIMENSION TABLE - NOT COUNTING SPLICES

ALL DIMENSIONS ARE OUT TO OUT


ALL BENDS ARE 2" RADIUS

_S

MARK
NO.

LIST

_)

EXPANSION JOINT

VARIES 5 3/4"

PLAN

TO

3'- 3"1

bl
+

I='
I

36'- 0"

G)# 4

&@ #

4 - 23 SPACES @ 1'- 6"

= 34'- 6"

iii

a:::

3/4" PREMOLDED JOINT


FILLER AT EXPANSION
JOINT (TYP.)

0::

..-

TOP OF
ROADWAY

I VARIES (B - 4 1/2") I
TO (C - 5 3/4")

ELEVATION

3/4" CHAMFER
(TYP.)

1 1/2"
CLR.

~ :i]z
~
w

(J)

Cl

(J)

....1

<(

::::>

0
w

1I

iii

i=

(J)

....1

!Il

;:!:
c:::
w

(J)

w
w
0:: (J)

c:::

c
SECTION

UP TO 10"

BARRIER
HEIGHT

HORIZONTAL
BARS {QTY.)

3'- 6"

8"

2'- 0"

4'- 10"

3" MIN.

10

4'- 0"
4'- 6"

9 1/8" 2'- 2 1/4"


10 1/4" 2'- 4 1/2"

5'- 0 1/4"

c:::

0
w

TABLE

UP TO 7"

.I

7" MIN.

5'- 2 1/2" 10" MIN.

12

14

!Il

;:!:

w w
0:: w

c:::

<(

!Il

DUMMY JOINT

....1

(J)

MONOTUBE SIGN STRUCTURE


SINGLE-SLOPE BARRIER ~
FOUNDATION (SEE BRIDGE PLANS)
~

~
CLR.
ISOMETRIC VIEW

SEE NOTE 1

0 TO 5"

iii

(J)

::::>

SECTION

GRADE
SEPARATION

....1

<(

!Il

1I

Cl

<(

(..)

~
~

~
CLR.

3/4" CHAMFER
(TYP.)

3'- 6"

0
(J)

(..)

b
..-

TRAILING END TRANSITION


(FROM MONOTUBE SIGN STRUCTURE
FOUNDATION TO SINGLE-SLOPE ~
DUAL-FACED BARRIER)
~

~
LEADING END TRANSITION
( _ (FROM SINGLE-SLOPE DUAL-FACED

SINGLE-SLOPE CONCRETE
BARRIER TRANSITION FOR
MONOTUBE SIGN SUPPORT
STANDARD PLAN C-85.18-00
SHEET 1 OF 1 SHEET

BARRIER TO MONOTUBE SIGN


STRUCTURE FOUNDATION)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

SINGLE-SLOPE CONCRETE BARRIER

SINGLE-SLOPE CONCRETE BARRIER

FOUNDATION

24'- 0" TAPER

4'- 0"

24'- 0" TAPER

12'- 0" (TYP.)


JA

EXPANSION JOINT (TYP.) -----;

t-r

B/~

'

....

---- ... '

-------------? -~~
'

---------------

'.,.

( _ EXPANSION JOINT
DUMMY JOINT (TYP.)

A/

_S

' '

- -

,'

' '

EXPANSION JOINT~

~ ___i_

3'- 3"

>-

---------------- r----------------

/y

L---1'

DUMMY JOINT

ID

NOTES
..
1. See Standard Spec1f1cat1on 8-21.3(9) for construction requirements .

1'-7 1/2"

&>

----.-

1-

2. Use a template to locate and secure the bolts during foundation installation.

PLAN

CANTILEVER SIGN STRUCTURE SEE STD. PLAN G-60.10

3. When connecting between cast-in-place and precast Single-Slope Barrier, provide


a Connection Blackout and Rebar Grid as shown in Standard Plan C-13.

~ ~

4. Grounding Conductor shall be non-insulated #4 AWG stranded copper, provide a


3' - 0" slack. Clamp steel reinforcing bar with connector suitable for use embedded
in concrete.

@# 4 AND@# 4 - 7 SPACES @

24'- 0"

6"

5. Install Conduit Coupling flush with top of Barrier. Do not glue PVC stubout.

= 3'- 6"
24'- 0"

G)# 4 AND@# 4- 15 SPACES @

1'- 6"

= 22'- 6"

G)# 4 AND@# 4 - 15 SPACES @

1'- 6"

= 22'- 6"

EXPANSION JOINT WITH 3/4"


PREMOLDED JOINT FILLER (TYP.)

EXPANSION JOINT WITH 3/4"


PREMOLDED JOINT FILLER (TYP.)

3/4" CHAMFER (TYP.)

TOP OF ROADWAY

DUMMY JOINT (TYP.)


1" STEEL CONDUIT OR AS
PER CONTRACT - WHEN
REQUIRED, CAP EACH END
w

....1

ID

SEE SECTION "A", SHEET 2 FOR


GROUNDING CONDUCTOR DETAILS
(SEE NOTE 4)

w
w

en
I

SEE SECTION "A", SHEET 2 FOR


SHAFT REINFORCEMENT DETAILS

MATERIAL SPECIFICATIONS
SHAFT
CONCRETE

::c

1-

a.

CLASS 4000P

ALL OTHER
CONCRETE

CLASS 4000

STEEL
REINF. BAR

AASHTO M 31
GRADE 60

ANCHOR RODS

ASTM F 1554
GRADE 105

TOTAL SIGN AREA


(SF)

ANCHOR NUTS

AASHTO M 291

13'- 0"

200 OR LESS

1500 AND UP

ANCHOR
WASHERS

AASHTO M 293

16'- 0"

200 OR LESS

1000 - 1499

ANCHORAGE
GALVANIZING

AASHTO M 232

18'- 0"

200 - 400

1500 AND UP

STEEL
PLATE

ASTM A 36

SHAFT

DEPTH

SINGLE-SLOPE CONCRETE
BARRIER CANTILEVER SIGN
STRUCTURE FOUNDATION
STANDARD PLAN C-85.20-00

SEE NOTE 3

22'- 0"

200 - 400

ALLOVVABLE LATERAL
BEARING PRESSURE
(PSF)

1000 - 1499

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ELEVATION

ISOMETRIC

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

GROUNDING CONDUCTOR - ROUTE TO


GROUNDING STUD (SEE NOTE 4)

ANCHOR ROD - 1 3/4" DIAM. x


(BARRIER HEIGHT + 4'- 2") LONG,
THREADED 8" MIN. EACH END; W/
FOUR HEAVY HEX NUTS AND
TWO WASHERS - GALVANIZE
o EXPOSED ANCHOR ROD END
~
1'- 0" MIN. (TYP.)

u.

BENDING

CONDUIT COUPLING - SEE NOTE 5

G)

PROVIDE SCREEN AROUND BASE - SEE SCREEN


DETAIL, STANDARD PLAN G-60.10, SHEET 4

3/4" CHAMFER (TYP.)

3/4"
CHAMFER
(TYP.)

3'- 3"

;,;

3/4"
CHAMFER
(TYP.)

DIAGRAM

VARIES 5"
TO 3'- 0"
3'- 0"

~
(j)

::::i

c:::=
wm

en
w

(.)

iten

TOP OF
ROADWAY

....1

<(

::::>
0
w

::c
(!) w
....1
iii III
::c
0:::

a:0:::

en

1 1/2" en
w
CLR. (.)

1-

en

b
.....

....1

<(

0::: 1-

w w
w
c:::en
<(
III

::::>
0
w

<(

III

1 1/2" en
w
CLR. (.)

::c
(!) w
....1
W III
::c <(

<(
ll.

w w
w

1-

<(
ll.

en

b
.....

....1

<(

::::>
0
w

a:

ii::+

C:::p

::c
(!) w
....1
W III
::c <(
0::: 1-

@#

(.)

<(

ro

III

@#

....1

::::>
0
w

....
I

en
en

5 (TYP.)

SECTION

SECTION0

:5
(.)

0
1-----r-:-:iARIES ( B -4 1/4")

w
w

"'"

0:::

(.)

TABLE

z
0

=II:

GRADE
SEPARATION

(.)

ANCHOR PLATE (TYP.) - SEE


STANDARD. PLAN G-60.20

w
....1
III

w
::c

<(

:::!:
0

.....'

III
w
0 ::c
0 1::c
I

....1

III
0:::

!;;:

0
0
0

....

en
en

:5
(.)

"'"

w
w

1-

z
0:::
en ::::>

....

II

::::>::c

ll.

I=0

ll.

8"

2'- 0"

4'-7"

3" MIN.

10

0 TO 5"

3'- 6"

UP TO 7"

4'- 0"

9 1/8" 2'- 2 1/4" 4'- 9 1/4"

7" MIN.

12

UP TO 10"

4'- 6"

10 1/4" 2'- 4 1/2" 4'- 11 1/2" 10" MIN.

14

~
~
~

ALL BENDS ARE 2" RADIUS


ALL DIMENSIONS ARE OUT TO OUT

0:::

0:::

(.)

z
0

1-

(.)

=II:~

ow
,.-,[[

1-1-

!Qa.

LOCATION

QTY.

LENGTH

SIZE

G)

BARRIER - TOP VERTICAL

32

VARIES

#4

32

VARIES

#4

23'- 8"

# 5

STR.

3'- 8"

# 5

STR.

BARRIER - BOTTOM VERTICAL


BARRIER - HORIZONTAL
BARRIER - HORIZONTAL

(.)>0:::~

(.)

(j)

CAP - HOOP

w
wQ:;
1-0
w
c:::o
uw

CAP -TOP
CAP - VERTICAL, EACH CORNER

SHAFT - SPIRAL

SHAFT - VERTICAL

-en
(!)~

z<C
-(!)
~<(

(.)ll.

w
z

MARK
NO.

Z(.)

(.)

LIST

G)

ow
zo
::::>
u.l-

o::s

:::!:
0

BAR

V5~N

::c 0
z
0

BARRIER
HEIGHT

IIIc:::w
_.<een
_.w

1-

0:::

w~w

<(

1i:"
1-

3'- 8"

I
I

i~t"_;.~-4114")~[: ~

1-

It)

""

~
CLR.

....

it

en

<(

0
0
0

3'- 8"
SQUARE

w w
a:c:::en
w

f/)

I
I

<C::c
III(!)
N-w
:s::c

1-

0
0

BARRIER - TOP VERTICAL

VARIES

#4

BARRIER - BOTTOM VERTICAL

VARIES

#4

15'- 9"

# 5

10'- 10"

# 5

3'- 4"

#4

1~

AS REQ'D

#4

12

"Z" MINUS
CLEARANCES

# 9

TYPE

STR.

STR.

Q.

SINGLE-SLOPE CONCRETE
BARRIER CANTILEVER SIGN
STRUCTURE FOUNDATION
STANDARD PLAN C-85.20-00
SHEET 2 OF 2 SHEETS

/,;\.. CONSTRUCTION JOINT WITH


"'!/ ROUGHENED SURFACE

SECTION

.A. SEE TABLE, THIS SHEET,


"'61' COLUMN "Q"

A IF JOINING TWO SPIRALS, SEE LAP SPLICE


""Y DETAIL, STANDARD PLAN G-60.20, SHEET 2
~ ADD TWO

#5 BARS, EQUALLY SPACED,

W AT THE TOP OF THE FOUNDATION BARRIER

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


06-16-11
-----------------------STATE DESIGN ENGINEER
DATE

.....

. . . Washington State Department of Transportation

NOTES

8
B

10 (DESIRABLE)

ROADSIDE INSTALLATION DETAIL

DIRECTION OF TRAFFIC
CONCRETE BARRIER
TERMINAL SECTION (TYP.)

8
8
8
B

8
8
B

88

88
88
88

88

88
88

88
88
88

TYPE 1

TYPE 2

TYPE 3

POSTED SPEED
40 MPH OR LESS

POSTED SPEED
45 MPH

POSTED SPEED
50 MPH

1. Approved Inertial Barrier Systems (sand barrel arrays) are listed


in the Qualified Products List and shall be installed in accordance
with the manufacturer's recommendations. When products not listed
on the Qualified Products List are considered, a Request of Approval
of Materials (RAM) form is required.
2.

For temporary installations, the inertial barriers may be placed


on wood pallets that are 4" or less in height.

PLAN VIEW

1oo (DESIRABLE)

MEDIAN INSTALLATION DETAIL

DIRECTION OF TRAFFIC
6"TYP

oo~~
-@@@@T@@@-

VARIES FROM 1' TO 2'

CONCRETE BARRIER
TERMINAL SECTION (TYP.)

DIRECTION OF TRAFFIC

GORE INSTALLATION DETAIL

8
8
8
88

8
8
8
8
88
88

88

88

88

88

TYPE 4

TYPE 5

TYPE 6

POSTED SPEED
55 MPH

POSTED SPEED
60 MPH

POSTED SPEED
70 MPH

8
8
8
8
88
88

88

88
88

EXAMPLE CONFIGURATION

88
88

88
88
IMPACT ATTENUATOR
INERTIAL BARRIER
CONFIGURATIONS
STANDARD PLAN C-90.10-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

PLAN VIEW

Pasco Bakotich Ill

INSTALLATION DETAILS

ATTENUATOR CONFIGURATIONS
(NUMBERS INSIDE BARRELS INDICATE LBS.)

.....

fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

TYPE 2A

WALL HT

BARS

IIAII&IIFII BAR"B"

IIDII&IIEII

BARS

IIAII&IIFII BAR"B"

TYPE2C
BARS

IIDII&IIEII

TYPE2D

BARS

IIAII&IIFII BAR"B"

BARS

IIDII&IIEII

BARS

BARS

IIAII&IIFII BAR"B"

IIDII&IIEII

WALL HT

6'- 0"

2'- 0"

5"

3- #4

#4@ 18"

#3@ 15"

2'- 3"

5"

3 -#4

#4@ 18"

#3@ 12"

2'- 0"

5"

3 -#4

#4@ 18"

#3@ 15"

2'- 6"

5"

3 -#4

#4@ 18" #3@ 11"

6'- 0"

8'- 0"

2'- 3"

5"

3- #4

#4@ 18"

#3@ 12"

2'- 9"

5"

3 -#4

#4@ 18"

#4@ 15"

2'- 6"

5"

3 -#4

#4@ 18"

#3@ 10"

3'- 3"

5"

5 -#4

#4@ 18" #4@ 12"

8'- 0"

10'- 0"

2'- 6"

5"

3- #4

#4@ 18"

#3@9"

3'- 3"

5"

5 -#4

#4@ 18"

#4@ 10"

2'- 9"

5"

3 -#4

#4@ 18"

#4@ 12"

3'- 6"

5"

5 -#4

#4@ 18" #4@ 10"

10'- 0"

12'- 0"

3'- 0"

5"

3- #4

#4@ 18"

#4@ 12"

3'- 9"

5"

5 -#4

#4@ 18"

#4@ 10"

3'- 3"

5"

3 -#4

#4@ 18"

#4@ 10"

4'- 3"

5"

5 -#4

#4@ 18" #5@ 12"

12'- 0"

14'- 0"

3'- 3"

5"

3- #4

#4@ 18"

#4@ 10"

4'- 3"

5"

5 -#4

#4@ 18"

#5@ 11"

3'- 9"

5"

3 -#4

#4@ 18"

#4@9"

4'- 9"

5"

5 -#4

#4@ 18" #5@8"

14'- 0"

16'- 0"

3'- 9"

5"

5- #4

#4@ 18"

#4@9"

4'- 9"

5"

5 -#4

#4@ 18"

#6@ 12"

4'- 3"

5"

5 -#4

#4@ 18"

#5@ 11"

5'- 6"

5"

5 -#4

#4@ 18" #6@9"

16'- 0"

18'- 0"

4'- 0"

5"

5- #4

#4@ 18"

#5@ 11"

5'- 3"

5"

5 -#4

#4@ 18"

#6@9"

4'- 6"

5"

5 -#4

#4@ 18"

#6@ 12"

6'- 0"

6"

5 -#4

#4@ 18" #6@9"

18'- 0"

20'- 0"

5'- 0"

5"

5- #4

#4@ 18"

#5@9"

6'- 0"

6"

5 -#4

#4@ 18"

#6@9"

5'- 3"

5"

5 -#4

#4@ 18"

#6@ 10"

6'- 6"

6"

5 -#4

#4@ 12" #6@ 7 1/4"

20'- 0"

22'- 0"

5'- 6"

5"

5- #4

#4@ 18"

#5@7"

6'- 3"

6"

5 -#4

#4@ 12"

#6@8"

5'- 9"

6"

5 -#4

#4@ 18"

#6@9"

7'- 0"

7"

5 -#4

#4@ 11" #6@7"

22'- 0"

24'- 0"

6'- 0"

5"

5- #4

#4@ 15"

#5@6"

6'- 9"

7"

5 -#4

#4@ 11"

#6@8"

6'- 3"

6"

5 -#4

#4@ 12"

#6@8"

7'- 6"

7"

5 -#4

#4@9"

24'- 0"

=WALL THICKNESS

TYPE 2B

BARS

RIGHT-OF-WAY

#6@ 61/4"

NOTES
1. Wall to be designated Noise Barrier Wall Type 2A,
28, 2C or 20. The Contract specifies actual wall
designations.
2. For intermediate wall heights not listed, use the
next higher H.
3.

Panels shall have at least 3 feet of level ground


on each side.

4. Construction joints in the footing shall be spaced


at 120 feet maximum.

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

~
WALL & FOOTING

SEE CONTRACT

3/4" CHAMFER (TYP.)


3"(TYP.)

SURFACE TREATMENT
AS REQUIRED

LEVEL (TYP.)

3" (TYP.)

2A

B1

80

2B

B1

90

2C

B2

80

2D

B2

90

~~~~

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINTS (TYP.)
@ 24' - 0" CENTERS

-~

ALTERNATE AS SHOWN

(!)

z
0

iten

~
:iii
ro
......
()

;;!;

#4 BAR
(TYP.)

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

3'- 0" MIN.

'
'
'
'
'
'
'
'
'
'

<0

'

CAST-IN-PLACE CONCRETE
WALL ON SPREAD FOOTING

BAR "D"
(TYP.)

~I

t-~--t

I ..
I
I
"I
I
~ I
r
,I
BAR "E"
II

~:iii
:iii =

FINAL GROUND LINE


I

BAR "E"
(TYP.)

:Z

:iE
b

'
TOP OF FOOTING

#4@

18'~
1'- 0"
MIN.
BAR "A" WITH 2' - 0" MIN.
SPLICE AND EXTENDING THRU
CONSTRUCTION JOINT (TYP.} ~

BAR "B" (TYP.)


1'- 0" (TYP.)

2'- 0" MIN.


LAP (TYP.)

LONGITUDINAL FOOTING
REINFORCING BAR "A" (TYP.)

BAR "F" (TYP.)

NOISE BARRIER WALL


TYPE2
STANDARD PLAN D-2.04-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

CONSTRUCTION
JOINT WITH
ROUGHENED
SURFACE

ALTERNATE
PLACEMENT
OF HOOKS

TYPICAL SECTION

A\. REQUIRED FOR WALLS 24' - 0" - TYPE 2C,

"'61" WALL HEIGHT 22' - 0" & 24' - 0" - TYPE 2B &
WALLS 20' - 0", 22' - 0" & 24' - 0" - TYPE 2D

ELEVATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

1'- 0" MIN. (TYP.)

1:......+-----______r-=======-=j.0

<CFOOllNG-

-~~-- ~---------- ~
~

----------------------

------r--

BAR "A" (TYP.) _ /


(TRANSVERSE BARS NOT SHOWN)

FOOTING WIDTH TRANSITION DETAIL


FOR LOCATIONS WITHOUT FOOTING STEP

3/4" CHAMFER (TYP.)


ANGLE POINT

1/2" NOISE
SEALER (TYP.)

CAST-IN-PLACE CONCRETE
WALL ON SPREAD FOOTING

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

TRAFFIC SIDE

JOINT AND CORNER DETAIL

NOISE BARRIER WALL


TYPE2
STANDARD PLAN D-2.04-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

TYPE3A

WALL HT

TYPE3B

BARS

6'- 0"

2'- 0"

5"

3 -#4

BARS

BARS
IID"&"EII

#4@ 18"

#3@ 15"

2'- 3"

5"

3 -#4

..A.. &"F" BAR"B"

TYPE3C
BARS

BARS
.. D..&"E ..

#4@ 18"

#3@ 12"

2'- 0"

5"

3 -#4

..A.. &.. F" BAR"B"

BARS

BARS
.. D..&"E ..

#4@ 18"

#3@ 15"

2'- 6"

5"

3 -#4

..A.. &.. F" BAR"B"

WALL HT
BARS
on&"En

#4@ 18"

#3@ 11"

6'- 0"

..A.. &.. F" BAR"B"

8'- 0"

2'- 3"

5"

3 -#4

#4@ 18"

#3@ 12"

2'- 9"

5"

3 -#4

#4@ 18"

#4@ 15"

2'- 6"

5"

3 -#4

#4@ 18"

#3@ 10"

3'- 3"

5"

5 -#4

#4@ 18"

#4@ 12"

8'- 0"

10'- 0"

2'- 6"

5"

3 -#4

#4@ 18"

#3@9"

3'- 3"

5"

5 -#4

#4@ 18"

#4@ 10"

2'- 9"

5"

3 -#4

#4@ 18"

#4@ 12"

3'- 6"

5"

5 -#4

#4@ 18"

#4@ 10"

10'- 0"

12'- 0"

3'- 0"

5"

3 -#4

#4@ 18"

#4@ 12"

3'- 9"

5"

5 -#4

#4@ 18"

#4@ 10"

3'- 3"

5"

3 -#4

#4@ 18"

#4@ 10"

4'- 3"

5"

5 -#4

#4@ 18"

#5@ 12"

12'- 0"

14'- 0"

3'- 3"

5"

3 -#4

#4@ 18"

#4@ 10"

4'- 3"

5"

5 -#4

#4@ 18"

#5@ 11"

3'- 9"

5"

5 -#4

#4@ 18"

#4@9"

5'- 3"

5"

5 -#4

#4@ 18"

#5@8"

14'- 0"

16'- 0"

3'- 9"

5"

5 -#4

#4@ 18"

#4@9"

5'- 3"

5"

5 -#4

#4@ 18"

#6@ 12"

4'- 3"

5"

5 -#4

#4@ 18"

#5@ 11"

6'- 3"

5"

5 -#4

#4@ 18"

#6@9"

16'- 0"

18'- 0"

4'- 0"

5"

5 -#4

#4@ 18"

#5@ 11"

6'- 0"

5"

5 -#4

#4@ 18"

#6@9"

5'- 0"

5"

5 -#4

#4@ 18"

#6@ 12"

7'- 0"

6"

5 -#4

#4@ 18"

#6@9"

18'- 0"

20'- 0"

5'- 0"

5"

5 -#4

#4@ 18"

#6@ 12"

7'- 0"

6"

5 -#4

#4@ 18"

#6@9"

5'- 9"

5"

5 -#4

#4@ 18"

#6@9"

8'- 0"

6"

6 -#4

#4@ 12"

#6@6"

20'- 0"

22'- 0"

5'- 6"

5"

5 -#4

#4@ 18"

#6@9"

7'- 9"

6"

6 -#4

#4@ 12"

#6@6"

6'- 6"

6"

5 -#4

#4@ 18"

#6@9"

9'- 0"

7"

7 -#4

#4@ 12"

#6@6"

22'- 0"

24'- 0"

6'- 3"

5"

5 -#4

#4@ 18"

#6@9"

8'- 6"

7"

6 -#4

#4@ 12"

#6@6"

7'- 6"

6"

6 -#4

#4@ 12"

#6@6"

9'- 9"

7"

7 -#4

#4@ 15"

#6@6"

24'- 0"

t
RIGHT-OF-WAY

=WALL THICKNESS

Wall to be designated Noise Barrier Wall


Type 3A, 38, 3C or 30. The Contract
specifies actual wall designations.

2.

For intermediate wall heights not listed, use


the next higher H.

3.

Panels shall have at least 3 feet of level


ground on each side.

4.

Construction joints in the footing shall be


spaced at 120 feet maximum.

3A

..
-~

ALTERNATE
AS SHOWN

=
co

+---1---+

I
I

(!)

J:

3'- 0" MIN.

_ _ _ _ _:__:_____:_:c.:..:.c:.:__ _ _

~~
rn

BAR "D"
(TYP.)

I
I

io
.....

2' - 0" FOR #3 & #4 BAR


2' - 2" FOR #5 BAR
2' - 7" FOR #6 BAR

r--

I
I

'

-+---1-

I
I

I
I

I
I

I
I

I
I

I
I

---r-

r---~-

+----1----+--+----1-

@)
FINAL
GROUND
LINE

~ ::i:
::i: =

#4 BAR
(TYP.)

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

TREATMENT

~-r

LEVEL (TYP.)

3/4" CHAMFER

SURFACE~

1.

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

~
WALL

SEE CONTRACT

NOTES

TYPE 3D

I
I

'I

'I

'I

I
I

1 I

-1---t--t--~---~
I

B1

90

B2

80

3D

B2

90

1-r----::>""------

l---r--1
~-_j--l-- 1
I

-~--i--t-~---r ~-~--+-I

3B
3C

-1---t--t--~---j

~--~--~--~--~-

;j{

I
I

II

80

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINTS (TYP.)
@ 24' - 0" CENTERS

I
I

-1---+--+-----l---r

B1

1
CAST-IN-PLACE CONCRETE
WALL ON OFFSET
SPREAD FOOTING

I
BAR"E"
(TYP.)

'I

BAR"E"
CONSTRUCTION
JOINT WITH
ROUGHENED
1
SURFACE
BAR "F"
(TYP.)

ALTERNATE PLACEMENT
OF HOOKS

w
TYPICAL SECTION

BAR "B"

BAR "A" WITH 2' - 0"


MIN. SPLICE AND
EXTENDED THRU
CONSTRUCTION
JOINT (TYP.) ~

MIN.

BAR "B" (TYP.)


1'- 0" (TYP.)

2'- 0" MIN.


LAP (TYP.)

LONGITUDINAL FOOTING
REINFORCING BAR "A" (TYP.)

1'- 0"
MIN.

NOISE BARRIER WALL


TYPE3
STANDARD PLAN D-2.06-01

REQUIRED FOR WALLS 24' - 0" - TYPE 3C,


WALL HEIGHT 22' - 0" & 24' - 0" - TYPE 3B,
& WALLS 20'- 0", 22'- 0" & 24'- 0"- TYPE 3D

~ WHEN W IS : < 2' - 6" ....................... CENTER WALL ON FOOTING


2'- 6' S. W < 4'- 6" ..... DIM.
~ 4' - 6" ....................... DIM.

= 1'- 0"
= 2' - 0"

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ELEVATION

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

BAR "A" (TYP.)


RIGHT-OF-WAY SIDE

TRAFFIC SIDE

1'- 0" MIN. (TYP.)

(TRANSVERSE BARS NOT SHOWN)

FOOTING WIDTH TRANSITION DETAIL


FOR LOCATIONS WITHOUT FOOTING STEP

3/4" CHAMFER (TYP.)


ANGLE POINT

CAST-IN-PLACE CONCRETE
WALL ON OFFSET
SPREAD FOOTING

1/2" NOISE
SEALER (TYP.)

2'- 0"

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

JOINT AND CORNER DETAIL

TRAFFIC SIDE

NOISE BARRIER WALL


TYPE3
STANDARD PLAN D-2.06-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

TYPE4A
WALL HT
H

SHAFT
DIAM.
D

6'- 0"

5"

8'- 0"

5"

10'- 0"

TYPE4B

TYPE4C

DEPTH

DEPTH

D1

D2

SHAFT
REIN F.
BAR"P"

12"

6'- 0"

5'- 3"

12"

7'- 0"

6'- 0"

5"

12"

7'- 9"

#3@9"

5"

12"

#4@ 12"

5"

14"

6 -#7

#4@ 10"

5"

7'- 9"

6 -#8

#4@9"

9'- 3"

7'- 9"

6 -#9

14"

9'- 3"

7'- 9"

14"

9'- 9"

8'- 3"

DEPTH

DEPTH

D1

D2

SHAFT
REIN F.
BAR"P"

IICII&IIDII

SHAFT
DIAM.
D

IICII&IIDII

SHAFT
DIAM.
D

12"

5'- 3"

4'- 9"

12"

6'- 0"

5'- 3"

6 -#5

#3@ 15"

5"

6 -#5

#3@ 15"

5"

6 -#5

#3@ 15"

5"

6 -#5

#3@ 12"

5"

5"

12"

6'- 9"

5'- 9"

6 -#5

#3@ 13"

6'- 9"

6 -#6

#4@ 15"

12'- 0"

5"

12"

14'- 0"

5"

12"

7'- 3"

6'- 3"

6 -#5

7'- 9"

6'- 9"

6 -#6

8'- 6"

7'- 3"

6 -#7

8'- 6"

7'- 3"

8 -#7

16'- 0"

5"

12"

8'- 6"

7'- 3"

16"

9'- 3"

8'- 0"

18'- 0"

5"

12"

9'- 0"

5"

16"

9'- 3"

20'- 0"

5"

12"

#4@ 7"

5"

16"

22'- 0"

5"

8 -#7

#4@6"

6"

24'- 0"

5"

8 -#8

#5@8"

6"

BARS

TYPE4D

DEPTH

DEPTH

D1

D2

SHAFT
REINF.
BAR"P"

12"

5'- 9"

5'- 0"

12"

6'- 6"

5'- 6"

5"

12"

7'- 3"

#4@ 10"

5"

12"

#4@9"

5"

12"

8 -#7

#5@ 11"

5"

14"

8'- 0"

6 -#8

#5@8"

5"

10'- 0"

8'- 6"

8 -#7

#5@ 7"

16"

10'- 6"

9'- 0"

8 -#8

16"

11'- 3"

9'- 6"

8 -#8

t =WALL THICKNESS

6 -#5

#3@ 15"

5"

12"

6'- 6"

5'- 9"

6- #5

#3@ 15"

6'- 0"

4A

B1

80

6 -#5

#3@ 15"

5"

12"

7'- 6"

6'- 6"

6- #6

#3@ 10"

8'- 0"

4B

B1

90

6'- 3"

6 -#5

#3@ 10"

5"

12"

8'- 3"

7'- 0"

6 -#7

#4@ 12"

10'- 0"

4C

B2

80

7'- 9"

6'- 9"

6 -#6

#4@ 12"

5"

14"

8'- 6"

7'- 3"

8 -#7

#4@ 10"

12'- 0"

4D

B2

90

8'- 6"

7'- 3"

6- #7

#4@ 10"

5"

14"

9'- 3"

8'- 0"

8 -#7

#5@ 11"

14'- 0"

8'- 6"

7'- 3"

8 -#6

#4@9"

5"

16"

9'- 6"

8'- 0"

8- #8

#5@8"

16'- 0"

14"

9'- 0"

7'- 9"

8- #7

#5@ 11"

5"

16"

10'- 0"

8'- 6"

8- #8

#6@9"

18'- 0"

5"

14"

9'- 9"

8'- 3"

8 -#8

#5@8"

6"

16"

10'- 9"

9'- 3"

8- #9

#6@9"

20'- 0"

SOIL
TYPE

ANGLE OF INTERNAL
FRICTION <I> (DEGREES)

#5@6"

5"

14"

10'- 3"

8'- 9"

8 -#9

#5@8"

6"

16"

11'- 6"

9'- 9"

8- #10

#6@7"

22'- 0"

D1

32

#6@ 7"

6"

16"

10'- 3"

8'- 9"

8 -#8

#6@7"

7"

18"

11'- 6"

9'- 9"

8- #10

#6@7"

24'- 0"

D2

38

BARS

DEPTH

DEPTH

D1

D2

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

IICII&IIDII

BARS

SHAFT
REINF.
BAR"P"

WALL HT
H

SHAFT
DIAM.
D

D
SHAFT DIAM.

BARS
IICII&IIDII

SOIL TYPE

NOTES
1. Wall to be designated Noise Barrier Wall
Type 4A, 48, 4C or 40. The Contract
specifies actual wall designations.

WALL & SHAFT


RIGHT-OF-WAY

,
~

2. For intermediate wall heights, see next


higher H.

BAR"P"

3.

I
.. I

SEE CONTRACT

W3.5 SPIRAL
@6" PITCH

SECTION

314" CHAMFER

--.----....---~1

I
I

en

135" HOOK

2" CLR.

SURFACE TREATMENT
AS REQUIRED

~
I

I"

6"MIN.
2'- 0"
MAX.
3" (TYP.)

#4 BAR (TYP.)

LEVEL (TYP.)

(TYP.)

Panels shall have at least 3 feet of level


ground on each side .

4. Construction joints in the shaft cap shall be


spaced at 120 feet maximum.
5. The Contract specifies actual foundation
requirements 01 or 02.

0::

(!)

(3
<(

D..

en

J:

<(

tO en en
:tJ;O::O::

ciS~~

M LO CO

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

'11:'11:'11:

~
:E

0::0::0::
000

Lo
.....

bNF--

@)

NNN

112" PREMOLDED JOINT


FILLER IN EXPANSION JOINTS
@ 24'- 0" CENTERS (TYP.)

ALTERNATE AS SHOWN

LL.LL.LL.

3'- 0" MIN.

1-----1--------'--rl

"

_j

_j_

l_

---~~-~-~-t--t--1----1

I I I I I

I I

CAST-IN-PLACE CONCRETE
WALL ON SHAFT FOUNDATION

t--~~-~---r--r--t--r----l--+-+ -t---+----1--1
I

I I I I I I I I I I I I I I I
1-ll_l_l_l_t--f----4--+---t-- -L-1-1

L_L_j __l_+-+-~-~~-~-+-~-~-1-_j

FINAL GROUND LINE


MAX.

~-LJ_J_J__l_
___l -J--~--rt-J-~-~1-~
I I I I I I 11 11 I I I I I

~1
D..

<(

a,u

,1-

-1---~-

r--~~----t--t-+-+--l---_j--l _ _l 1_ ___1_1

BAR"D"
(TYP.)

6"MAX.

TOP OF FINAL
GROUND LINE

LL.

.-<(

J:

en

c
0::
0

....
c

9"

9"

1' 6"

--'-------- rn
TYPICAL SECTION

NOISE BARRIER WALL


TYPE4

#4 STIRRUPS

4-#40R ~
5- #4 BARS
CONSTRUCTION JOINT
WITH ROUGHENED SURFACE

A\. #4- TOTAL 8 BARS (TYP.)

"'61" (WHEN H = 6'- 0" TO 12'- 0")


#4- TOTAL 10 BARS (WHEN
H = 14' - 0" TO 24' - 0") WITH
2' - 0" MIN. LAP SPLICE

CONSTRUCTION JOINT
- (SEE NOTE 4)

STANDARD PLAN D-2.08-00


SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

1'- 6" MIN., 5'- 0" MAX.,


SEE DETAIL "B" FOR
SHAFT REINFORCEMENT

15'- 0" MAX. SHAFT SPACING

ELEVATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

ct_ SHAFT
9"

PLACE HOOKS PARALLEL


TO WALL LAYOUT LINE (TYP.)

It)

I-

SPACING @ 12"

rb

THREE SPACES

@6"

w
w
en

#4 STIRRUP

I
N

c
a::
0

:E

~
0...
a::

L1..

::c

I(!)

....
c

I-

I-

::c

::c

CONCRETE SHAFT

I-

0...

....1

L1..
<(

en

SHAFT REINFORCMENT
W3.5 SPIRAL
@ 6" PITCH

DETAIL "B"

CAST-IN-PLACE CONCRETE
WALL ON SHAFT FOUNDATION

1/2" NOISE
SEALER (TYP.)
ANGLE POINT

314" CHAMFER (TYP.)

2'- 0"

__._ _ _ _ _

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

NOISE BARRIER WALL


TYPE4

_h_
2

STANDARD PLAN D-2.08-00


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

TRAFFIC SIDE

Harold J. Peterfeso

JOINT AND CORNER DETAIL

.....

STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

TYPE SA

WALL HT

TYPE6C

6'- 0"

5'- 6"

3"

#4@ 12"

#4@ 12"

5'- 6"

3"

#4@ 12"

#4@ 12"

5'- 6"

3"

#4@ 12"

#4@ 12"

5'- 6"

3"

#4@ 12"

#4@ 12"

6'- 0"

8'- 0"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

8'- 0"

10'- 0"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

10'- 0"

12'- 0"

5'- 0"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 12"

#4@ 12"

12'- 0"

14'- 0"

4'- 9"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 11"

#4@ 11"

4'- 9"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 10"

#4@ 10"

14'- 0"

16'- 0"

5'- 0"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 10"

#4@ 10"

5'- 0"

3"

#4@ 10"

#4@ 10"

5'- 6"

3"

#4@ 12"

#5@ 12"

16'- 0"

18'- 0"

5'- 0"

3"

#4@ 10"

#4@ 10"

5'- 3"

3'- 0" #4@ 12"

#5@ 12"

5'- 0"

3'- 0" #4@ 10"

#4@ 10"

5'- 9"

3"

#4@9"

#5@9"

18'- 0"

0
RIGHT-OF-WAY

~WALL

BARS
IIBII&IICII

BARS
IIDII&IIEII

BARS
IIBII&IICII

BARS
IIDII&IIEII

6A

B1

80

6B

B1

90

6C

B2

80

6D

B2

90

~-

:Z

:E ~

2. For intermediate wall heights, use the next


higher H.

4. Construction joints in the foundation shall


be spaced at 120 feet maximum.

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINTS (TYP.)
@ 24' - 0" CENTERS MAX.

1/2" NOISE
SEALER (TYP.)

2'- 0"

~
I

21/2"

~'-------<------ -~

LEVEL (TYP.)

= b
co '

1. Wall to be designated Noise Barrier Wall


Type 6A, 68, 6C or 60. The Contract
specifies actual wall designations.

3. Panels shall have at least 3 feet of level


ground on each side.

ANGLE POINT

CONSTRUCTION JOINT WITH


ROUGHENED SURFACE

NOTES

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

2 1/2"

-=-

~
3/4" CHAMFER (TYP.)

TRAFFIC SIDE

----------------------~

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

ALTERNATE
SIDES

PROVIDE A SMOOTH PROFILE CONSISTENT


WITH ROADWAY PROFILE

t~
---.------------.----+-1
~

~ HEIGHT MAY VARY IF REQUIRED TO

SEE CONTRACT

BARS
IIDII&IIEII

WALL HT

BARS
IIDII&IIEII

BARS
IIBII&IICII

TYPE6D

~
I

TYPE 6B

BARS
IIBII&IICII

CORNER
PANEL

SURFACE TREATMENT
AS REQUIRED

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

JOINT AND CORNER DETAIL

en

BENDING DIAGRAM

rn.,....

7' - 5" FOR #3 OR

r r

\f~ROR

2" R

CAST-IN-PLACE CONCRETE
WALL W/ TRAFFIC BARRIER
ON SPREAD FOOTING

~ 1_10"+X

BAR "B"
BAR "B"
#4 (TYP.) - PLACE
AS SHOWN

#4@ THREE
EQUAL SPACES

BAR "C"

BAR"E"

TOP OF
ROADWAY

<&a,

FINAL
GROUND LINE
2" MIN.
6" MAX.

3" CLR.
(TYP.)

TOP OF
FOOTING

#4@ 18"

~[t

~ 6-~--

f2 ~

:;....

1'-1 3/4"

PROVIDE AN ADDITIONAL
#4 BAR TOP AND BOTIOM
WHEN "X" EXCEEDS 3"

~ #4 (TYP.) PLACE AS SHOWN WITH

TYPICAL SECTION

2' - 0" SPLICE AND EXTENDING THRU


CONSTRUCTION JOINTS

__ _

1'- 0" MIN.


(TYP.)

----------------------------

-- - - -

BAR "A"
(TYP.)
BARS "B", "C", "D" & "E" SPACE AS SHOWN ON TABLES

ELEVATION

NOISE BARRIER WALL


TYPE&
STANDARD PLAN D-2.14-00

FOOTING WIDTH TRANSITION DETAIL

SHEET 1 OF 1 SHEET

(FOR LOCATIONS WITHOUT FOOTING STEP)

APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPESSSA

WALL HT
H

6'- 0"

TYPESSSB

BARS

BARS

IIBII&IICII

non&nEn

5'- 6"

3"

#4@ 12"

#4@ 12"

8'- 0"

5'- 3"

3"

#4@ 12"

10'- 0"

5'- 3"

3"

12'- 0"

5'- 0"

14'- 0"

TYPESSSC
X

BARS

IIBII&IICII

non&nEn

WALL HT
H

5'- 6"

3"

#4@ 12"

#4@ 12"

6'- 0"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

8'- 0"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

10'- 0"

3"

#4@ 12"

#4@ 12"

5'- 0"

3"

#4@ 12"

#4@ 12"

12'- 0"

4'- 9"

3"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 10"

#4@ 10"

14'- 0"

#4@ 10"

5'- 0"

3"

#4@ 10"

#4@ 10"

5'- 6"

3"

#4@ 12"

#5@ 12"

16'- 0"

#5@ 12"

5'- 0"

3'- 0" #4@ 10"

#4@ 10"

5'- 9"

3"

#4@9"

#5@9"

18'- 0"

BARS

IIBII&IICII

non&nEn

5'- 6"

3"

#4@ 12"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

#4@ 12"

5'- 3"

3"

3"

#4@ 12"

#4@ 12"

5'- 0"

4'- 9"

3"

#4@ 12"

#4@ 12"

16'- 0"

5'- 0"

3"

#4@ 12"

18'- 0"

5'- 0"

3"

#4@ 10"

RIGHT-OF-WAY

SEE CONTRACT

..

TYPESSSD
BARS

BARS

BARS

BARS

IIBII&IICII

non&nEn

5'- 6"

3"

#4@ 12"

#4@ 12"

#4@ 12"

5'- 3"

3"

#4@ 12"

#4@ 12"

#4@ 12"

5'- 3"

3"

3"

#4@ 12"

#4@ 12"

5'- 0"

5'- 0"

3"

#4@ 11"

#4@ 11"

#4@ 12"

5'- 0"

3"

#4@ 10"

#4@ 10"

5'- 3"

3'- 0" #4@ 12"

~WALL

t~I

B1

80

6SSB

B1

90

6SSC

B2

80

6SSD

B2

90

2. For intermediate wall heights, use the next


higher H.
3. Panels shall have at least 3 feet of level
ground on each side.
4. Construction joints in the foundation shall be
spaced at 120 feet maximum.

ANGLE POINT

LEVEL (TYP.)

= b

(0

6SSA

1. Wall to be designated Noise Barrier Wall


Type 6SSA, 6SSB, 6SSC or 6SSD. The
Contract specifies actual wall designations.

1/2" PREMOLDED JOINT FILLER


____-- IN EXPANSION JOINTS (TYP.)
@ 24' - 0" CENTERS MAX.

:Z
~ ~

.. :

NOTES

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

2'- 0"

'

1/2" NOISE
SEALER (TYP.)

~
'

~~ -~-=-~

--------------------~

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

---.------------.---+

21/2"

2 1/2"

3/4" CHAMFER (TYP.)

TRAFFIC SIDE

~
~

SURFACE TREATMENT
AS REQUIRED

ALTERNATE
SIDES

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

en

JOINT AND CORNER DETAIL

::!!:
In
~

3" CLR.
(TYP.)
+-----------------~

J:

~[t

~ 6-~--

fr ~

__ _

1'- 0" MIN.


(TYP.)

----------------------------

CAST-IN-PLACE CONC. WALL


W/ SINGLE SLOPE TRAFFIC
BARRIER ON SPREAD FOOTING

BAR"A"
(TYP.)

TOP OF
ROADWAY

FOOTING WIDTH TRANSITION DETAIL

#4@ THREE
EQUAL SPACES

(FOR LOCATIONS WITHOUT FOOTING STEP)

FINAL
GROUND LINE
TOP OF
FOOTING

:Z
~

BENDING DIAGRAM

'

7' - 5" FOR #3 OR

#4BAROR~L

'

;....

7' - 7" #5 BAR


SEE NOTE 4

1'-1 3/4"

PROVIDE AN ADDITIONAL
#4 BAR TOP AND BOTTOM
WHEN "X" EXCEEDS 3"

_I_

BARS "B", "C", "D" & "E" SPACE AS SHOWN ON TABLES

1_10"+X

BAR"E"

ELEVATION

NOISE BARRIER WALL


TYPE6SS
STANDARD PLAN D-2.16-00

TYPICAL SECTION

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

VARIES

CONSTRUCTION
JOINT WITH
ROUGHENED SURFACE

~ HEIGHT MAY VARY IF REQUIRED TO


PROVIDE A SMOOTH PROFILE CONSISTENT
WITH ROADWAY PROFILE

#4 (TYP.) PLACE AS SHOWN WITH


2' - 0" SPLICE AND EXTENDING THRU
CONSTRUCTION JOINTS

Harold J. Peterfeso

BAR"B"

BAR"C"

.....

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPE7A
BARS
nen&ncn

TYPE 7B
BARS
nen&ncn

TYPE 7C
BARS
nen&ncn

TYPE7D
BARS
IIBII&IICII

WALL HT

NOTES
WALL HT

ANGLE POINT

6'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

6'- 0"

8'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

8'- 0"

10'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

10'- 0"

12'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 12"

12'- 0"

14'- 0"

#4@ 15"

#4@ 11"

#4@ 14"

#4@ 10"

14'- 0"

16'- 0"

#4@ 14"

#4@ 10"

#4@ 10"

#5@ 12"

16'- 0"

18'- 0"

#4@ 12"

#5@ 12"

#4@ 10"

#5@9"

18'- 0"

RIGHT-OF-WAY

SEE CONTRACT

0:::

~
0

"'

:I:

1....1

<(
C!)

z
C3
<(

c::
<(

;j{C::
ciS

;a

<3)

C') II)

=11:=11:

c::c::

D..

00

~
::!!:

ON

(/)

W3.5 SPIRAL
@ 6" PITCH

CONSTRUCTION JOINT
WITH ROUGHENED
SURFACE
HEIGHT MAY VARY IF REQUIRED TO
PROVIDE A SMOOTH PROFILE CONSISTENT
WITH ROADWAY PROFILE

6"MIN.

~~
--.--------

1'-0"MAX.~

~~ll

===-::::l
-~-

'-I

::>(f)

2" MIN .
6" MAX.

b
'

90
80

7D

B2

90

SOIL TYPE
SOIL
TYPE

ANGLE OF INTERNAL
FRICTION ~ (DEGREES)

D1

32

D2

38

CAST-IN-PLACE CONCRETE
WALL W/ TRAFFIC BARRIER ON
SHAFT FOUNDATION

-4-+-+-~-l_L ___ II

- 4 -~-~-~---,-r-rl

I
-It-

----U----R.---1+--JL-

TOP OF ROADWAY

EXTEND SHAFT
REINFORCEMENT
INTO BARRIER AND
BEND AS REQUIRED
AT FACE OF
BARRIER (TYP.)

B1
B2

~-i-i-1-t_T_f_r-rl

-~-

ow
we..>

7B
7C

LEVEL (TYP.)

1 I I I I I I I I I
~~~-~-+-+-+-+-~-L-LI I I I I I I I I

-I<(

80

-r-r-r-~-~-~-~-~-

;;I;

....1

B1

BAR"C"

-~-

(g)

7A

(f)

~~)
rn~ ~
BAR"B"

NN

#4 BAR

SHAFT

Ln

l F

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

#4 BAR

SECTION

LL.LL.

. . . rf.

3 1/2"

135" HOOK

tO(/)

BENDING DIAGRAM

6 -#8
BAR"A"

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

<(

(/)

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

CORNER
PANEL

2" CLR.

(/)

4. The Contract specifies actual foundation requirements 01 or 02.

3/4" CHAMFER (TYP.)

'
SURFACE TREATMENT
~ AS REQUIRED

(/)

z~
c::

3. Panels shall have at least 3 feet of level ground on each side.

JOINT AND CORNER DETAIL

3/4" CHAMFER (TYP.)

....1
(.)

1. Wall to be designated Noise Barrier Wall Type 7A, 78, 7C or 70.


The Contract specifies actual wall designations.
2. For intermediate wall heights, use the next higher H.

1'- 4" DIAM.

~WALL
I

1/2" NOISE
SEALER (TYP.)

2'- 0"

BAR "E" (TYP.)

TOP OF ROADWAY

c
c::
0

LL.

:I:

"'io' .....w
c::

d 1/2'~0 1f2'

1-

..... w
w
c (/)

c::

1-

C!)

1LL.

<(

:I:

(/)

LL.

W3.5SPIRAL~~=
@ 6" PITCH

4 SPACES
@9"MAX.

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINTS AT
24' - 0" CENTERS MAX. (TYP.)

=3'- 0"

4 SPACES@

1'- 0"= 4'- 0"

I
1

BARS "B" & "C"

STANDARD PLAN D-2.18-00

SPACE BARS "D" & "E" AS SHOWN

a.'

1'- 6" MIN.


5'- 0" MAX.

_ _ _ ____,__ _. 1 _

10' - 0" MAX. SHAFT SPACING

SECTION

4 SPACES
@ 9" MAX.
3' - 0"

SHEET 1 OF 1 SHEET

&.
BAR "A"

NOISE BARRIER WALL


TYPE7

....1

~JOINT

ELEVATION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPE 7SSA
BARS
nen&ncn

TYPE7SSB
BARS
nen&ncn

TYPE7SSC
BARS
IIBII&IICII

TYPE7SSD
BARS
IIBII&IICII

WALL HT

6'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

6'- 0"

8'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

8'- 0"

10'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

10'- 0"

12'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 12"

12'- 0"

14'- 0"

#4@ 15"

#4@ 11"

#4@ 14"

#4@ 10"

14'- 0"

16'- 0"

#4@ 14"

#4@ 10"

#4@ 10"

#5@ 12"

16'- 0"

18'- 0"

#4@ 12"

#5@ 12"

#4@ 10"

#5@9"

18'- 0"

RIGHT-OF-WAY

SEE CONTRACT

n-

BENDING DIAGRAM

WALL HT

51/2"

~I\

tid~
q

~
l

ell

NOTES

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

7SSA

B1

80

7SSB

B1

90

7SSC

B2

80

7SSD

B2

90

#4 BAR

1. Wall to be designated Noise Barrier Wall Type 7SSA, 7SSB,


7SSC or 7SSO. The Contract specifies actual wall designations.
2. For intermediate wall heights, use the next higher H.
3. Panels shall have at least 3 feet of level ground on each side.
4. The Contract specifies actual foundation requirements 01 or 02.

SOIL TYPE

BAR"B"

BAR"C"

1'- 4" DIAM.

~
SHAFT
I

SOIL
TYPE

ANGLE OF INTERNAL
FRICTION I!> (DEGREES)

D1

32

D2

38

ANGLE POINT

1/2" NOISE
SEALER (TYP.)

2'- 0"

6 -#8
BAR"A"
3/4" CHAMFER (TYP.)

0:::

....1
(.)

2" CLR.

W 3.5 SPIRAL
@ 6" PITCH

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

(/)
(/)

<(

<(

....1

;j{C::

C!)

ciS

<(

c::c::

;a

SHAFT

CONSTRUCTION JOINT
WITH ROUGHENED
SURFACE

~
::!!:

ON

JOINT AND CORNER DETAIL

~~

LEVEL (TYP.)

~------

-~-~-~-~-~-~-t--t-----+

3" (TYP.).. I

=11:=11:

00

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

CORNER
PANEL

C') II)

D..

(/)

c::

<(
tO(/)

z
C3

(k

SECTION
(/)

1-

TRAFFIC SIDE

'
SURFACE TREATMENT
~ AS REQUIRED

:I:

z~
c::

3/4" CHAMFER (TYP.)


135 HOOK

LL.LL.

6 1/2" TYP.

NN

Ln

~ HEIGHT MAY VARY IF REQUIRED TO

(g)

PROVIDE A SMOOTH PROFILE CONSISTENT


WITH ROADWAY PROFILE

;;I;

I I I I I I I I I
-~-+-+-+-+-~-L-L1 I I I I I I I I I
-4-+-+-~-l_L_L_II
I I I I I I I I I I
- 4 -~-~-~-l-,-r-rl
I I I I I I I I I

CAST-IN-PLACE CONC. WALL


WI SINGLE SLOPE TRAFFIC
BARRIER ON SHAFT FOUNDATION

~-1-1-1-t-T_f_r_rl
----U----R.----.----ll--

BAR "E" (TYP.)


TOP OF ROADWAY
TOP OF ROADWAY

ac::

EXTEND SHAFT
REINFORCEMENT
INTO BARRIER AND
BEND AS REQUIRED
AT FACE OF
BARRIER (TYP.)

LL.

<vl

'

Co

c::

W@
3.56"SPIRAL
PITCH

10 1/2"110 1/2"

.....

f~l

c
c::

:I:
1-

C!)

....1

ILL.

1 4 SPACES
@9"MAX.
I
3'- 0"

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINTS AT
24' - 0" CENTERS MAX. (TYP.)

(/)

4 SPACES@
1'- 0" = 4'- 0"

SPACE BARS "D" & "E" AS SHOWN

1
' BARS "B" & "C"

NOISE BARRIER WALL


TYPE7SS
STANDARD PLAN D-2.20-00

LL.

&!
BAR "A"

'

1'- 6" MIN.


1 5'- 0" MAX.

SHEET 1 OF 1 SHEET

10' - 0" MAX. SHAFT SPACING

APPROVED FOR PUBLICATION

~JOINT

....

Harold J. Peterfeso

---------'----'---

SECTION

4 SPACES
@ 9" MAX.
3' - 0"

ELEVATION

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPE9A

WALL HT

IIDII&IIHII

BAR"B"

TYPE9D
BARS

6'- 0"

2'- 0"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 15"

2'- 3"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 12"

2'- 0"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 15"

2'- 6"

BAR"B"

SPIRAL
BAR"G"

BARS

BARS
IIAII&IIFII

IIDII&IIHII

BARS
IIAII&IIFII

BAR"B"

SPIRAL
BAR"G"

BARS
D&H

SPIRAL
BAR"G"

IIDII&IIHII

BARS
IIAII&IIFII

BAR"B"

3 -#4

5"

#4@ 18"

W2.0@ 2"

#3@ 11"

WALL HT
H
6'- 0"

8'- 0"

2'- 3"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 12"

2'- 9"

3 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 15"

2'- 6"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 10"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 2"

#4@ 12"

8'- 0"

10'- 0"

2'- 6"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@9"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

2'- 9"

3 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 12"

3'- 6"

5 -#4

5"

#4@ 18"

W3.0@ 2"

#4@ 10"

10'- 0"

12'- 0"

3'- 0"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 12"

3'- 9"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

4'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 12"

12'- 0"

14'- 0"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

4'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 11"

3'- 9"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@9"

4'- 9"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@8"

14'- 0"

16'- 0"

3'- 9"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@9"

4'- 9"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@ 12"

4'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 11"

5'- 6"

5 -#4

5"

#4@ 18"

W4.0@ 2"

#6@9"

16'- 0"

18'- 0"

4'- 0"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 11"

5'- 3"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@9"

4'- 6"

5 -#4

5"

#4@ 18"

W4.0 @2"

#6@ 12"

6'- 0"

5 -#4

6"

#4@ 18"

W4.0@ 2"

#6@9"

18'- 0"

20'- 0"

5'- 0"

5 -#4

5"

#4@ 18"

W3.0@ 11/2" #5@9"

6'- 0"

5 -#4

6"

#4@ 18"

W4.0@2"

#6@9"

5'- 3"

5 -#4

5"

#4@ 18"

W4.0 @2"

#6@ 10"

6'- 6"

6 -#4

6"

#4@ 12"

W4.0@ 1 3/4" #6@ 7"

20'- 0"

22'- 0"

5'- 6"

5 -#4

5"

#4@ 18"

W3.0@ 11/2" #5@7"

6'- 3"

5 -#4

6"

#4@ 12"

W4.0@ 1 3/4" #6@8"

5'- 9"

5 -#4

6"

#4@ 18"

W4.0 @2"

#6@9"

7'- 0"

6 -#4

7"

#4@ 12"

W4.0@ 1 3/4" #6@ 7"

22'- 0"

24'- 0"

6'- 0"

5 -#4

5"

#4@ 15"

W3.0@ 11/2" #5@6"

6'- 9"

5 -#4

7"

#4@ 11"

W4.0@ 1 3/4" #6@8"

6'- 3"

5 -#4

6"

#4@ 12"

W4.0@ 1 3/4" #6@8"

7'- 6"

6 -#4

7"

#4@ 15"

W4.0@ 11/2" #6@6"

24'- 0"

=WALL THICKNESS

v
1-

TYPE9C

TYPE9B
SPIRAL
BAR"G"

BARS

BARS
IIAII&IIFII

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)
9A

B1

80

9B

B1

90

9C

B2

80

90

B2

90

BENDING DIAGRAM

b,{JW/2 MINUS
N
1 1/2"

NOTES
1.

Wall to be designated Noise Barrier Wall Type


9A, 98, 9C or 9D. The Contract specifies
actual wall designation.

2.

For intermediate wall heights, use the next higher H.

3.

Panels shall have at least 3' - 0" of level ground


on each side.

4.

Construction joints in the footing shall be spaced


at 120 feet maximum.

5.

All joints shall be in full contact and sealed.

BAR"H"

~WALL

RIGHT-OF-WAY

SEE CONTRACT

I
,

#3BAR
(TYP.)

PRECAST PANEL- TO BE
PLACED VERTICALLY

V
I

0~ ~:: ~

2 _ ..

PANEL WIDTH 12' - 0" MAX.


LEVEL (TYP.)

r---------------------~---L--------~

PRECAST CONCRETE WALL


ON SPREAD FOOTING

SEE JOINT DETAIL

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL

NOISE SEALER
1/2" (TYP.)
BAR"D"
(TYP.)

2"
FINAL
GROUND
LINE

2'- 1"

HOLE FOR
DOWEL BAR
MAX.

BAR "F"
BAR "A" WITH 2' - 0" MIN.
SPLICE EXTENDING THRU
CONSTRUCTION JOINT (TYP.)0
#4@ 18"0
BAR"H"ALTERNATE
PLACEMENT OF HOOKS

NOISE BARRIER WALL


TYPE9
BAR"H"

TYPICAL SECTION
0

2'-0"MI~.

CONSTRUCTION JOINT
(SEE NOTE 4)

REQUIRED FOR WALL HEIGHT 24' - 0" - TYPE 9C,


WALLS 22' - 0" & 24' - 0" - TYPE 9B & WALLS
20' - 0", 22' - 0" & 24' - 0" - TYPE 9D.

LAP (TYP.)

BAR "B"

STANDARD PLAN D-2.32-00


SEE

SHEET 1 OF 2 SHEETS

DETAIL@~

APPROVED FOR PUBLICATION

1'- 0"

ELEVATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

3/4" CHAMFER (TYP.)


ANGLE POINT

112" NOISE
SEALER (TYP.)

2'- 0"

__._ _ _ _ _ _ _

112._

~
CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

3" (TYP.)

TRAFFIC SIDE

JOINT AND CORNER DETAIL

WALL
BAR"D"

BAR "G" SPIRAL

PRECAST CONCRETE WALL


ON SPREAD FOOTING

1'- 0" MIN. (TYP.)


FILL VOID WITH GROUT

GROUT
DUCT
JOINT HOLE- 2" I. D. WITH
ROUGHENED SURFACE,
OR RIGID POST-TENSIONED
DUCT, OR CORRUGATED
STEEL PIPE

GROUT PAD

_t ____ _

(!)

i=

0
0

11..
--------------------------

---~

BAR "A" (TYP.)


TRANSVERSE BARS NOT SHOWN

FOOTING WIDTH TRANSITION DETAIL


FOR LOCATIONS WITHOUT FOOTING STEP

FOOTING

FILL THE JOINT HOLE WITH GROUT USING DUCTS.


DUCTS SHALL BE LOCATED ON PANEL FACE
OPPOSITE TRAFFIC

DETAIL

NOISE BARRIER WALL


TYPE9
STANDARD PLAN D-2.32-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

TYPE 10A

WALL HT
H

BARS
IIA"&"FII

BAR"B"

6'- 0"

2'- 0"

3- #4

5"

#4@ 18"

TYPE10B
BARS
"D"&"H"

W2.0 @2"

#3@ 15"

SPIRAL
BAR"G"

BARS
"An&f"

BAR"B"

2'- 3"

3 -#4

5"

#4@ 18"

TYPE 10C
BARS

SPIRAL
BAR"G"

TYPE10D

IIDII&IIHII

BARS
..A..&"f ..

BAR"B"

SPIRAL
BAR"G"

W2.0 @2"

#3@ 12"

2'- 0"

3 -#4

5"

#4@ 18"

BARS

BARS
"D"&"H"

IIDII&IIHII

BARS
"A"&"f..

BAR"B"

SPIRAL
BAR"G"

W2.0 @2"

#3@ 15"

2'- 6"

3- #4

5"

#4@ 18"

W2.0 @2"

#3@ 11"

WALL HT
H
6'- 0"

8'- 0"

2'- 3"

3- #4

5"

#4@ 18"

W2.0 @2"

#3@ 12"

2'- 9"

3 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 15"

2'- 6"

3 -#4

5"

#4@ 18"

W2.0 @2"

#3@ 10"

3'- 3"

5- #4

5"

#4@ 18"

W3.0 @2"

#4@ 12"

8'- 0"

10'- 0"

2'- 6"

3- #4

5"

#4@ 18"

W2.0 @2"

#3@9"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

2'- 9"

3 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 12"

3'- 6"

5- #4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

10'- 0"

12'- 0"

3'- 0"

5- #4

5"

#4@ 18"

W3.0 @2"

#4@ 12"

3'- 9"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

3'- 3"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

4'- 3"

5- #4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 12"

12'- 0"

14'- 0"

3'- 3"

5- #4

5"

#4@ 18"

W3.0 @2"

#4@ 10"

4'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 11"

3'- 9"

5 -#4

5"

#4@ 18"

W3.0 @2"

#4@9"

5'- 3"

5- #4

5"

#4@ 18"

W3.0@ 1 3/4"

#5@8"

14'- 0"

16'- 0"

3'- 9"

5- #4

5"

#4@ 18"

W3.0 @2"

#4@9"

5'- 3"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@ 12"

4'- 3"

5 -#4

5"

#4@ 18"

W3.0@ 1 3/4" #5@ 11"

6'- 3"

5- #4

5"

#4@ 18"

W4.0@2"

#6@9"

16'- 0"

18'- 0"

4'- 0"

5- #4

5"

#4@ 18"

W3.0@ 1 3/4"

#5@ 11"

6'- 0"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@9"

5'- 0"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@ 12"

7'- 0"

5- #4

6"

#4@ 18"

W4.0@2"

#6@9"

18'- 0"

20'- 0"

5'- 0"

5- #4

5"

#4@ 18"

W3.0@ 11/2"

#5@9"

7'- 0"

5 -#4

6"

#4@ 18"

W4.0@2"

#6@9"

5'- 9"

5 -#4

5"

#4@ 18"

W4.0@2"

#6@ 10"

8'- 0"

6- #4

6"

#4@ 12"

W4.0@ 1 3/4"

#6@ 7"

20'- 0"

22'- 0"

5'- 6"

5- #4

5"

#4@ 18"

W3.0@ 11/2"

#5@7"

7'- 9"

5 -#4

6"

#4@ 12"

W4.0@ 1 3/4"

#6@8"

6'- 6"

5 -#4

6"

#4@ 18"

W4.0@2"

#6@9"

9'- 0"

6- #4

7"

#4@ 12"

W4.0@ 1 3/4"

#6@ 7"

22'- 0"

24'- 0"

6'- 3"

5- #4

5"

#4@ 15"

W3.0@ 11/2"

#5@6"

8'- 6"

5 -#4

7"

#4@ 11"

W4.0@ 1 3/4"

#6@8"

7'- 6"

5 -#4

6"

#4@ 12"

W4.0@ 1 3/4" #6@8"

9'- 9"

6- #4

7"

#4@ 15"

W4.0@ 1 3/4"

#6@6"

24'- 0"

t = WALL THICKNESS

BENDING DIAGRAM

(lfj~-~-11~'

<t WALL

RIGHT-OF-WAY
SEE CONTRACT

0:::
....1

(.)

BAR"H"

10A

B1

80

1.

Wall to be designated Noise Barrier Wall


Type 10A, 108, 10C or 100. The Contract
specifies actual wall designation.

10B

B1

90

2.

For intermediate wall heights, use the next higher H.

10C

B2

80

3.

10D

B2

90

Panels shall have at least 3' - 0" of level ground


on each side.

4.

Construction joints in the footing shall be spaced


at 120 feet maximum.

5.

All joints shall be in full contact and sealed.

PANEL WIDTH 15'- 0" MAX.

3/4" CHAMFER

LEVEL (TYP.)

6" MIN.
2'- 0" MAX.

SURFACE TREATMENT
AS REQUIRED

ALTERNATE
AS SHOWN

NOTES

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

REINFORCING STEEL
BAR "D" - CENTERED
ON WALL
PRECAST PANEL - TO BE
PLACED VERTICALLY

J:

PRECAST CONCRETE WALL


ON OFFSET SPREAD FOOTING

SEE JOINT DETAIL


3'- 0" MIN.

BAR "D"
(TYP.)

2" X 2'- 1"


JOINT HOLE FOR
DOWEL BAR

FINAL
GROUND
LINE

4MIN.

~~

~
2MAX.

~-------S~--------------,1---------------~~1

BAR "F"

'

BAR "A" WITH 2' - 0" MIN.


SPLICE EXTENDING THRU
CONSTRUCTION JOINT (TYP.)0

.....
0:::

BAR "H"

BAR "A" (TYP.)


2MAX.

CONSTRUCTION JOINT
(SEE NOTE 4)

w
TYPICAL SECTION

SEE

b
M

....1
(.)

BAR"H"ALTERNATE
PLACEMENT
OF HOOKS

UNDISTURBED
SOIL

DETAIL@~

NOISE BARRIER WALL


TYPE 10
STANDARD PLAN D-2.34-01
SHEET 1 OF 2 SHEETS

REQUIRED FOR WALL HEIGHT 24'- 0"- TYPE 10C,


WALLS 22'- 0" & 24'- 0"- TYPE 10B & WALLS
20'- 0", 22'- 0" & 24'- 0"- TYPE 10D.

~ WHEN W IS :

< 2' - 6" ....................... CENTER WALL ON FOOTING

2'- 6' ~ W < 4'- 6" ..... DIM.= 1'- 0"


~ 4' - 6" ....................... DIM. = 2' - 0"

APPROVED FOR PUBLICATION

ELEVATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

3/4" CHAMFER (TYP.)


1/2" NOISE
SEALER (TYP.)

ANGLE POINT

2'- 0"

-------
----

IJ.L

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

3" (TYP.)

TRAFFIC SIDE

/
/

JOINT AND CORNER DETAIL

1" CLR. (TYP.)

1'- 0" MIN. (TYP.)

PRECAST CONCRETE WALL


ON OFFSET SPREAD FOOTING

BAR "G" SPIRAL

(!)

FILL VOID WITH GROUT

z
i=

u..

-Gl

JOINT HOLE- 2" I. D. WITH


ROUGHENED SURFACE,
OR RIGID POST-TENSIONED
DUCT, OR CORRUGATED
STEEL PIPE

BAR "A" (TYP.)


(TRANSVERSE BARS NOT SHOWN)

FOOTING WIDTH TRANSITION DETAIL


GROUT PAD

FOR LOCATIONS WITHOUT FOOTING STEP

NOISE BARRIER WALL


TYPE 10
STANDARD PLAN D-2.34-01
SHEET 2 OF 2 SHEETS

FOOTING
FILL THE JOINT HOLE WITH GROUT USING DUCTS.
DUCTS SHALL BE LOCATED ON PANEL FACE
OPPOSITE TRAFFIC

DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

TYPE 11A
WALL HT
H

DEPTH
D1

DEPTH
D2

BAR"A"

TYPE 11B

BAR"B"

ANCHOR
BOLT
DIAM.

DEPTH
D1

DEPTH
D2

BAR"A"

TYPE 11C

BAR"B"

ANCHOR
BOLT
DIAM.

DEPTH
D1

DEPTH
D2

BAR"A"

BAR"B"

ANCHOR
BOLT
DIAM.

DEPTH
D1

DEPTH
D2

BAR"A"

4 -#3

4 -#7

3'- 4"

3/4"

5'- 9"

5'- 0"

4-#3

4 -#7

3'- 4"

3/4"

5'- 3"

4'- 9"

4 -#3

4 -#7

3'- 4"

1"

6'- 3"

5'- 3"

4 -#3

4 -#7

3'- 4"

3/4"

6'- 0"

8'- 0"

5'- 6"

5'- 0"

4 -#3

4 -#7

3'- 4"

3/4"

6'- 6"

5'- 9"

4-#3

4 -#7

3'- 4"

3/4"

6'- 0"

5'- 3"

4 -#3

4 -#7

3'- 4"

1"

7'- 0"

6'- 0"

4 -#3

4 -#7

3'- 4"

3/4"

8'- 0"

10'- 0"

6'- 3"

5'- 3"

4 -#3

4 -#7

3'- 4"

3/4"

7'- 3"

6'- 3"

4-#4

4 -#7

3'- 4"

3/4"

6'- 9"

5'- 9"

4 -#3

4 -#7

3'- 4"

1"

8'- 0"

6'- 9"

4 -#4

4 -#7

3'- 4"

3/4"

10'- 0"

12'- 0"

6'- 9"

5'- 9"

4 -#3

4 -#7

3'- 4"

3/4"

8'- 0"

6'- 9"

4-#4

4 -#7

3'- 4"

3/4"

7'- 6"

6'- 3"

4-#4

4 -#7

3'- 4"

1"

8'- 9"

7'- 3"

4 -#5

4 -#7

3'- 4"

3/4"

12'- 0"

14'- 0"

7'- 3"

6'- 3"

4 -#4

4 -#7

3'- 4"

3/4"

8'- 9"

7'- 6"

4-#5

4 -#7

3'- 4"

3/4"

8'- 0"

6'- 9"

4-#4

4 -#7

3'- 4"

1"

9'- 6"

8'- 0"

4 -#5

4 -#9

5'- 6"

1"

14'- 0"

16'- 0"

7'- 9"

6'- 9"

4 -#4

4 -#7

3'- 4"

1"

9'- 6"

8'- 0"

4-#6

4 -#7

3'- 4"

1"

8'- 9"

7'- 3"

4 -#5

4 -#9

5'- 6"

1"

10'- 3"

8'- 6"

4 -#6

4 -#9

5'- 6"

1"

16'- 0"

18'- 0"

8'- 6"

7'- 0"

4 -#5

4 -#9

5'- 6"

1"

10'- 3"

8'- 6"

4-#6

4 -#9

5'- 6"

1"

9'- 3"

7'- 9"

4 -#6

4 -#9

5'- 6"

1"

11'- 0"

9'- 3"

4- #7

4- #11

8'- 5"

1"

18'- 0"

20'- 0"

9'- 0"

7'- 6"

4 -#5

4 -#9

8'- 5"

1"

10'- 9"

9'- 0"

4 -#7

4 -#9

8'- 5"

1"

10'- 0"

8'- 3"

4 -#6

4- #11

8'- 5"

1"

11'- 9"

9'- 9"

4 -#8

6- #11

8'- 5"

1"

20'- 0"

22'- 0"

9'- 6"

8'- 0"

4 -#6

6- #11

8'- 5"

1"

11'- 6"

9'- 6"

4-#8

6- #11

8'- 5"

1"

10'- 6"

8'- 9"

4 -#7

6- #11

8'- 5"

1"

12'- 6"

10'- 3"

4 -#8

SPECIAL DESIGN REQUIRED

22'- 0"

24'- 0"

10'- 0"

8'- 3"

4 -#6

SPECIAL DESIGN REQUIRED

10'- 0"

4-#8

SPECIAL DESIGN REQUIRED

11'- 3"

9'- 3"

4 -#7

SPECIAL DESIGN REQUIRED

13'- 3"

11'- 0"

4 -#9

SPECIAL DESIGN REQUIRED

24'- 0"

'I' RIGHT-OF-WAY SIDE

12'- 0"

HOLE DIAM. =
BOLT DIAM. + 1/8"
(SEE TABLE)

BAR "C" - #3 LAP SPLICE


TO HORIZONTAL BARS
WI 1' - 0" MIN. SPLICE

'~

BAR "D" - #3 TIE


@ 12" O.C. MAX.

~[

1__.
J:

<(

cj

t5

SURFACE
TREATMENT
..... AS REQUIRED
@)

::::!:
N

SECTION

WALL TO BE SET PLUMB

<->
@)

4. The Contract specifies actual foundation


requirements D1 or 02.

ISOMETRIC VIEW
SHOWN FOR INSTALLATION

en
w

5. Maximum Panel length shall be 12 feet.

PLATE DETAIL

ANCHOR BOLT ALTERNATIVE

i=

3. Panels shall have at least 3 feet of level


ground on each side.

--------1

3/4" CHAMFER {TYP.)

PRECAST CONCRETE
PANEL ON PILASTER

2. For intermediate wall heights, use the next


higher H.

'-----------'1

~L ~- - - - -1.

cten

1. Wall to be designated Noise Barrier Wall


Type 11A, 11 B, 11 C or 11 D. The Contract
specifies actual wall dimensions.

. I

CONCRETE PILASTER
3/4" CHAMFER {TYP.)

NOTES

;(

(!)

WALL
HEIGHT
H

4'- 6"

SHAFT &
PILASTER

0::

ANCHOR
BOLT
DIAM.

5'- 0"

t.

~
w
!;(

BAR"B"

6'- 0"

TRAFFIC SIDE

en
__.

TYPE 11D

THREADED ROD WITH NUTS TOP AND BOTTOM

ClPILASTER
AND SHAFT

=II:

en

BAR "C" - #3 LAP SPLICE


TO HORIZONTAL BARS
W/1'- 0" MIN. SPLICE

i=

PRECAST CONCRETE WALL


ON SHAFT FOUNDATION
ANCHOR BOLT
(TYP.)

#3 SPIRAL

FINAL GROUND LINE

~~~~~~
....!,__ _ _

-t---T;~II.--~~

2" CLR.

BAR "B" (TYP.)


1 MAX.

GROUT

~PILASTER

___ Cl PILASTER
AND SHAFT

NOISE SEALER
1/2" (TYP.)

AND SHAFT

BAR "F"- #3@ 12" BOTH DIRECTIONS,


OR 6 X 6-W5.5 X W5.5, OR 12 X 12-W9.5
x W6.5, OR W9.5 (D10) HORIZONTAL@
12" O.C. WITH W6 (D6) VERTICAL@ 12"
O.C. OR EQUIVALENT. CENTER HORIZONTAL BAR ON WALL. ALTERNATE
VERTICAL BARS AS SHOWN.

CONTINUOUS
SHEAR KEY
J:

(.)

1-

0::

a:

.....

@)

J:
1-

a..
w

Cl

lo

ANCHOR BOLTS - SET BOLTS


WITH TEMPLATE. USE NUTS
TOP & BOTTOM OF TEMPLATE
TO SECURE LOCATION.

.....

BAR "F"

SECTION

SECTION

__.

SEE ANCHOR BOLT


ALTERNATIVE

1:2

a:
en

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

2'- 6"

PANEL LENGTH- 12'- 0" MAX.

=II:

ANCHOR SPIRAL
WITH TWO TURNS
TOP AND BOTTOM

6 -#8

B1

80

11B

B1

90

11C

B2

80

NOISE BARRIER WALL


TYPE 11

11D

B2

90

STANDARD PLAN D-2.36-02

~-~-~-~-~~-~-~-~-~-~-~-~---~~

ri
LJ

TYPICAL SECTION

11A

PLAN VIEW

TYPICAL PANEL

SHEET 1 OF 3 SHEETS

SOIL TYPE
SOIL
TYPE
D1
D2

ANGLE OF INTERNAL
FRICTION <I> (DEGREES)
32
38

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

NOTE

DIMENSION TABLE

NOTE

A0

THE BOTTOM 9" OF BAR "B" SHALL BE PAINTED WITH


ONE COAT OF FORMULA A-6-86 ZINC DUST OXIDE
PRIMER OR, ONE COAT OF FORMULA A-11-99 PRIMER.

F0

T
1 1/2"

#7

1 21/32"

1 1/8"

#9

2"

1 3/8"

1 3/4"

1 21/32"

2 1/4"

#11

2 15/32"

ANCHOR BOLTS, NUTS, WASHERS, BASE PLATE,


AND BAR "B" SHALL HAVE A PROTECTIVE COATING OF ONE OF THE FOLLOWING: HOT DIPPED
GALVANIZING AASHTO M 232 FOR HARDWARE;
AASHTO M 111 FOR WASHERS AND PLATES:
MECHANICAL GALVANIZING AASHTO M 298
CL 55, OR ZINC RICH PAINT, PAINT THREADS
AND NUTS AFTER INSTALLATION.

BAR "B"

BLOCK-OUT - 10" LONG,


GROUT AFTER BOLTING
DEFORMED
REINF. BAR
BASE PLATE
THREADED
REINF. BAR
LOCK NUT
SET THE ELEVATION OF THE
LEVELING NUTS BEFORE
SETTING THE PANEL

HARDENED WASHER
HEX NUT

NUTS WITH HARDENED WASHERS OR


PLATE WASHERS 1/4" X 2 1/4" X 2 1/4"
AASHTO M 183 (TYP.)

BAR "B"
THREADED BAR OPTION

BAR "B"

THE WEDGE HEAD SHALL BEAR FIRMLY AND UNIFORMLY


AGAINST THE BASE PLATE. BAR "B" SHALL BE HELD
SECURE DURING CONCRETE PLACEMENT TO PREVENT
GAPS BETWEEN THE WEDGE HEAD AND THE BASE PLATE.

NO TAPER IS REQUIRED ON THE BASE PLATE


WHEN USING THE THREADED BAR OPTION,
USE DIAM. F HOLES

DETAIL

6" MIN.

HOLE FOR BAR "B" (TYP.)


(TAPERED FOR WEDGE ~
HEAD SHOWN)

SLOT FOR ANCHOR BOLT (TYP.) (ANCHOR BOLT DIAM. + 1/4") X 2 1/2"
BASE PLATE- T X 10" X 1'- 5",
AASHTO M 183, GALVANIZED,
3/4" CHAMFER ALL CORNERS
(EMBEDDED WITH GROUT)

TOP OF PILASTER

2'-0"MAX.~
TOP OF
ADJACENT
PANEL

ANCHOR BOLT (TYP.) - ASTM F 1554-04


GRADE 55 MATERIAL (SEE TABLE
FOR DIAMETER)

2"
LEVEL (TYP.)
~----'-......---..l..------l

PRECAST CONCRETE WALL


ON SHAFT FOUNDATION

1'- 2"
1'- 5"

ELEVATION VIEW

PLAN VIEW

STEP DETAIL

SHEAR-KEY DETAIL

1 1/2"

LOCATIONS WHEN (SIX) 6 HOLES


ARE REQUIRED (SEE TABLE)

BASE PLATE
BENDING DIAGRAM

BAR "B" AND BASE PLATE DETAILS


'>"----------1 _ 2"

.1

#3 TIES @ 12" O.C. MAX.

BAR "C"

BAR "D"

I"

ALTERNATE THE
CENTER TIE
LOCATIONS

#3 TIES @ 3" O.C. MAX.

STANDARD PLAN D-2.36-02

BAR "E"

OUTSIDE OF PILASTER TO OUTSIDE OF PILASTER MINUS 4 1/2"

,z
BAR"F"

VARIES TO
MATCH ANGLE

NOISE BARRIER WALL


TYPE 11

Ill

At

SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


01-06-09
----------------------STATE DESIGN ENGINEER
DATE

.......
fll

Washington State Department of Transportation

I.

5' - 0" MAX. {TYP.)

SHAFT {TYP.)

go MAX.

SEAL - 1/2" {TYP.)

DETAIL

END OF PANEL

ENDOFWALL

5' - 0" MAX. {TYP.)

ANGLE POINT - CANTILEVERED

PANEL LENGTH - 12'- 0" MAX. {TYP.)


SURFACE TREATMENT
AS REQUIRED {TYP.)

END-PANEL OPTIONS

20 MAX.
20
MAX.

PRECAST CONCRETE WALL


ON SHAFT FOUNDATION

SHAFT {TYP.)

ANGLE POINT - ON SHAFT


ANGLE 20 OR LESS
((SHAFT AND
PANEL

((SHAFT AND
PANEL
I

#3

II

ANGLE
BAR "A" {TYP.)

BAR "B"
{TYP.)

#3 {TYP.)

All

DIMENSION

30

4 1/2"

40

5 1/2"

so

6 1/2"

60

7 1/4"

70

7 3/4"

ao
go

8"

NOISE BARRIER WALL


TYPE 11
STANDARD PLAN D-2.36-02

g 1/4"

SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

ANGLE POINT - ON SHAFT


ANGLE 20 TO

go

Pasco Bakotich Ill


01-06-09
----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

TYPE13A

TYPE13B

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

WALL HT
H

6'- 0"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

6'- 0"
8'- 0"

BAR"E"

BAR"E"

BAR"E"

BAR"E"

8'- 0"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

10'- 0"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 12" #4@ 12" #3@ 12"

#5@ 12"

10'- 0"

12'- 0"

5'- 0"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 0"

1"

#4@ 10" #4@ 10" #3@ 10"

#5@ 10"

5'- 0"

1"

#4@ 12" #4@ 12" #3@ 12"

#5@ 15"

5'- 0"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

12'- 0"

14'- 0"

4'- 9"

1"

#4@ 11" #4@ 11" #3@ 11"

#5@ 11"

5'- 0"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

4'- 9"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 11"

5'- 3"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

14'- 0"

16'- 0"

5'- 0"

10"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 12"

5'- 6"

1'- 6" #4@ 13" #5@ 13" #5@ 13"

#5@ 13"

16'- 0"

18'- 0"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 3"

1'- 6" #4@ 12" #5@ 12" #5@ 12"

#5@ 12"

5'- 0"

1'- 0" #4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 9"

1 - 9"

#5@9"

18'- 0"

'

FILL VOID WITH GROUT

A. GROUT
~ DUCT

2" I.D. WITH ROUGHENED


SURFACE, OR RIGID POSTTENSIONED DUCT, OR
CORRUGATED STEEL PIPE

DETAIL

CORNER
PANEL

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

80

13B

B1

90

13C

B2

80

13D

B2

90

PANEL WIDTH 15'- 0" MAX.

JOINT AND CORNER DETAIL

#5@9"

2. For intermediate wall heights, use the next higher H.


3. Panels shall have at least 3 feet of level ground on each side.
4. Construction joints in the footing shall be spaced at 120 feet max.
5. All joints shall be in full contact and sealed.
6. The Contract specifies actual foundation requirements 01 or 02.
BENDING DIAGRAM

2" R

#3

_}7\

DUCTS SHALL BE LOCATED ON PANEL FACE


OPPOSITE TRAFFIC

11_

1 1/2" CLR. (TYP.)

..

RIGHT-OF-WAY

REINFORCING STEEL BAR "D"


(CENTERED ON WALL)

'i-l
'

~-~

___[

---------.--

PRECAST PANEL
TO BE PLACED
VERTICALLY

BAR"B"

-+--+
I I

j _ _J

I
I

I
I

j _ _j_
ALTERNATE SIDES

3/4" CHAMFER
#4 - PLACE AS SHOWN
#4@ THREE
EQUAL SPACES

3'- 0" MIN.


#4 - PLACE AS SHOWN
1 1/2" CLR.

r::-R.--0-~~

NOISE SEALER
1/2" (TYP.)

MAX. 1

~~I~~::.Y;';\Y?;;-~

12~\) :CL
I ~I
hj
8

BAR"C"

10"+X

_j1f
~ ~W-X-41/2'

BAR"E"

BAR"J"

PRECAST CONCRETE WALL


W/ TRAFFIC BARRIER ON
SPREAD FOOTING

1----r-

TOP OF
ROADWAY

ixl

FINAL GROUND LINE

#5@9"

1. Wall to be designated Noise Barrier Wall Type 13A, 138,


13C or 130. The Contract specifies actual wall designations.

HEIGHT MAY VARY IF REQUIRED TO PROVIDE


A SMOOTH PROFILE CONSISTENT WITH THE
ROADWAY PROFILE

I
I

B1

LEVEL (TYP.}

~ FILL THE JOINT HOLE WITH GROUT USING DUCTS.

(l WALL
SEE CONTRACT

3/4" CHAMFER (TYP.)

13A

TRAFFIC SIDE

21/2"

2 1/2"

GROUT PAD

FOOTING

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

~~ -~=-~

\
BAR "E" OR "J"

#4@9"

NOTES

1/2" NOISE
SEALER (TYP.}

BAR "G" - SPIRAL

WALL

t:::=

TYPE13D

BARS
IIBII&IICII

ANGLE POINT

TYPE13C

WALL HT
H

1-----::-:c-------.--~---~ ~

NOISE BARRIER WALL


TYPE 13
#4@ 18"

STANDARD PLAN D-2.42-00

#4 TYP. - PLACE AS SHOWN W/


2' - 0" SPLICE AND EXTENDING
THRU CONSTRUCTION JOINTS

REINFORCEMENT

#4 - PLACE IN HEEL
WHEN X= 1"
GROUT PAD LEVELING COURSE.
SET PANEL IMMEDIATELY
SECTION
AFTER PLACING GROUT

SHEET 1 OF 1 SHEET
SEE NOTE 4

1'- 1 3/4"

TYPICAL SECTION

BARS "B", "C", "D",


"E" & "J" SPACE AS
SHOWN ON TABLES

ELEVATION

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPE13SSA

TYPE13SSC

TYPE13SSB

TYPE13SSD

WALL HT
H

BARS
BAR"E"
IIBII&IICII

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

BARS
IIBII&IICII

BAR"D"

BAR"J"

WALL HT
H

6'- 0"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 6"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

6'- 0"
8'- 0"

BAR"E"

BAR"E"

BAR"E"

8'- 0"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

10'- 0"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 3"

1"

#4@ 12" #4@ 12" #3@ 12"

#5@ 12"

10'- 0"

12'- 0"

5'- 0"

1"

#4@ 15" #4@ 15" #3@ 15"

#5@ 15"

5'- 0"

1"

#4@ 10" #4@ 10" #3@ 10"

#5@ 10"

5'- 0"

1"

#4@ 12" #4@ 12" #3@ 12"

#5@ 15"

5'- 0"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

12'- 0"

10"

14'- 0"

4'- 9"

1"

#4@ 11" #4@ 11" #3@ 11"

#5@ 11"

5'- 0"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

4'- 9"

1"

#4@ 12" #5@ 12" #4@ 12"

#5@ 11"

5'- 3"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

14'- 0"

16'- 0"

5'- 0"

10"

#4@ 12" #5@ 12" #4@ 12"

#5@ 12"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 12"

5'- 6"

1'- 6" #4@ 13" #5@ 13" #5@ 13"

#5@ 13"

16'- 0"

18'- 0"

5'- 0"

10"

#4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 3"

1'- 6" #4@ 12" #5@ 12" #5@ 12"

#5@ 12"

5'- 0"

1'- 0" #4@ 10" #5@ 10" #4@ 10"

#5@ 10"

5'- 9"

1 - 9"

#5@9"

18'- 0"

BAR "D"
OR "C"
\

1/2" NOISE
SEALER (TYP.)

ANGLE POINT

BAR "G" - SPIRAL

WALL

FILL VOID WITH GROUT

'

\
BAR "E" OR "J"

~~ -~=-~

~GROUT

2" I.D. WITH ROUGHENED


SURFACE, OR RIGID POSTTENSIONED DUCT, OR
CORRUGATED STEEL PIPE

DUCT

2 1/2"

DETAIL

314" CHAMFER (TYP.)

B1

80

13SSB

B1

90

13SSC

B2

13SSD

B2

NOTES
1. Wall to be designated Noise Barrier Wall Type 13SSA, 13SSB,
13SSC or 13SSO. The Contract specifies actual wall designations.
2.

For intermediate wall heights, use the next higher H.

80

3.

Panels shall have at least 3 feet of level ground on each side.

90

4. Construction joints in the footing shall be spaced at 120 feet maximum.

6. The Contract specifies actual foundation requirements 01 or 02.


BENDING DIAGRAM

JOINT AND CORNER DETAIL

HEIGHT MAY VARY IF REQUIRED TO PROVIDE


A SMOOTH PROFILE CONSISTENT WITH THE
ROADWAY PROFILE

(l WALL

DUCTS SHALL BE LOCATED ON PANEL FACE


OPPOSITE TRAFFIC
1-oo-------~-,! ___[ 1 1/2" CLR. (TYP.)
!

~RIGHT-OF-WAY

r"
1

LEVEL (TYP.)

2"R

PANEL WIDTH 15'- 0" MAX.


BAR"B"

------------.-#3

REINFORCING STEEL BAR "D"


(CENTERED ON WALL)

#5@9"

5. All joints shall be in full contact and sealed.

REINFORCED PER
LISTED WALL HEIGHT
REINFORCEMENT TABLE

CORNER
PANEL

~ FILL THE JOINT HOLE WITH GROUT USING DUCTS.


SEE CONTRACT

13SSA

#5@9"

TRAFFIC SIDE

GROUT PAD

FOOTING

21/2"

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
TYPE
(MPH)

#4@9"

PRECAST PANEL
TO BE PLACED
VERTICALLY

--r-

NOISE SEALER
1/2" (TYP.)

,---T
=

:
\_L

-:\':

11~ty~ ~L
~
][

hi

BAR"C"

10"+X

_jl[
~W-X-41/2"

BAR"E"

BAR"J"

PRECAST CONCRETE WALL W/


SINGLE SLOPE TRAFFIC BARRIER
ON SPREAD FOOTING

ALTERNATE SIDES

3/4" CHAMFER
#4 - PLACE AS SHOWN
#4@ THREE
EQUAL SPACES

3'- 0" MIN.

0
......

FINAL GROUND LINE

SEE DETAIL A

MAX. 1

J~l;;;:::::Y7~7;;:Yw-~

TOP OF
ROADWAY

:Z

:iE
0

NOISE BARRIER WALL


TYPE 13SS

'

STANDARD PLAN D-2.44-00


#4 TYP. - PLACE AS SHOWN W/
2' - 0" SPLICE AND EXTENDING
THRU CONSTRUCTION JOINTS

SHEET 1 OF 1 SHEET

#4 - PLACE IN HEEL
WHEN X= 1"

REINFORCEMENT SECTION

GROUT PAD LEVELING COURSE.


SET PANEL IMMEDIATELY
AFTER PLACING GROUT

1'- 1 3/4"

TYPICAL SECTION

BARS "8", "C", "D",


"E" & "J" SPACE AS
SHOWN ON TABLES

ELEVATION

APPROVED FOR PUBLICATION

SEE NOTE 4

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

TYPE14A

TYPE14B

TYPE 14C

TYPE14D

BAR"A"

BAR"A"

BAR"A"

BAR"A"

6'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

6'- 0"

8'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

8'- 0"

10'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

10'- 0"

WALL HT

nr.

WALL HT

12'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

12'- 0"

14'- 0"

#4@ 15"

#4@ 11"

#4@ 15"

#4@ 10"

14'- 0"

r==

#4@ 10"

#4@ 10"

#4@ 10"

#5@ 12"

16'- 0"

18'- 0"

#4@ 10"

#5@ 12"

#4@ 10"

#5@ 12"

18'- 0"

-.-----

-~r----1-~

z ~
~ :::!!:
&> b
'

j'...

'

'

""

'

-~

2 8!
:::!!: 1
' !
=
:::!!:
m

I!'-

1~

SEE CONTRACT

WIND
VELOCITY
(MPH)

14A

B1

80

~ ~

14B

B1

90

14C

B2

80

3. Panels shall have at least 3 feet level ground on each side.

14D

B2

90

4. All joints shall be in full contact and sealed.

U1r

WALL

3/4" CHAMFER (TYP.)

rr:

..

2. For intermediate wall heights, use the next higher H.

6. The bottom 9" of Bar "B" shall be painted with one coat of Formula
A-6-86 Zinc Dust Oxide Primer OR, one coat of Formula A-11-99
Primer.

RIGHT-OF-WAY SIDEi

1. Wall to be designated Noise Barrier Wall Type 14A, 14B, 14C


or 14D. The Contract specifies actual wall designations.

5. Anchor Bolts, Nuts, Washers, Base Plate, and Bar "B" shall have
a Protective Coating of one of the following: Hot Dipped
Galvanizing AASHTO M 232 for Hardware; AASHTO M 111
for Washers and Plates: Mechanical Galvanizing AASHTO M 298
CL 55, or Zinc Rich Paint, Paint threads and nuts after installation.

1 1/4" THREADED ROD


WITH NUTS TOP
& BOTTOM (TYP.)

.,,I

WIND
EXPOSURE

4 1/!'1

~
RIGHT-OF-WAY

NOISE
BARRIER
TYPE

4 1/-t'l

WALL

NOTES

WIND EXPOSURE & VELOCITY

~\ f~
_
_...,~

""

_L__

CD

-~

16'- 0"

BENDING DIAGRAM

TRAFFIC SIDE

7. The Contract specifies actual foundation requirements D1 or D2 .

....1

t>
1/2" SEAL FULL
HEIGHT (TYP.)

BAR "A" CENTERED ON


WALL SEE CHART FOR
BAR SIZE AND
SPACING (TYP.)

WALL TO BE SET
PLUMB (TYP.)

1'- 8"

SURFACE TREATMENT
AS REQUIRED ~

#3@ 1'- 3" O.C.


ALTERNATE
SIDES (TYP.)

OPTIONAL 2' - 0"


MIN. SPLICE

3" (TYP.)

PLATE

-j

1 1/2" (TYP.)

III

:I

1 318" DIAM. (TYP.)

'11*-llr------1

ISOMETRIC VIEW
SHOWN FOR INSTALLATION

OPTIONAL 2' - 0"


MIN. SPLICE

PLATE

1- #4@ END OF BARRIER

0
~

1 -#4@ END ~
OF BARRIER

HEIGHT MAY VARY IF REQUIRED TO


PROVIDE A SMOOTH PROFILE CONSISTENT
WITH THE ROADWAY PROFILE

PRECAST CONCRETE WALL


W/ TRAFFIC BARRIER ON
SHAFT FOUNDATION

~BARRIER

'CY

AND SHAFT

a;

'

ANCHOR PLATE DETAIL

CONSTRUCTION JOINT W/
ROUGHENED SURFACE

BLOCKOUT FOR SHEAR KEY

7"

0- #4 @ END OF BARRIER
OPTIONAL

c::j======hol f~

ANCHOR BOLTS

1
SEE DETAIL C

2" CLR.
#3 SPIRAL@
4" PITCH

12- #5 (TYP.)

0:::

u..
b

~Cia

0:::

....
c

#4@ 12"

0:::

TOP OF
ROADWAY

u..

m
'

""

Cia

1-

'

t>

0::

....
@)
....1

0::

en

1 1/4" ANCHOR BOLT. SET


BOLTS WITH TEMPLATE. USE
NUTS TOP AND BOTTOM OF
TEMPLATE TO SECURE
LOCATION .

NOISE BARRIER WALL


TYPE14

FOR ALTERNATIVE ANCHOR


SEE ANCHOR PLATE DETAIL

STANDARD PLAN D-2.46-00

#8 (TYP.)

SHEET 1 OF 2 SHEETS

b
.....

3" MIN.,
9" MAX.

-~SHAFT

4- #8 BAR "B"
J:

2'- 6"
ANCHOR SPIRAL WITH TWO
TURNS TOP AND BOTTOM

SECTION
TYPICAL SECTION

SECTION AT SHAFT SUPPORT

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

(20" MAX.)/2

\1.5-

~JOINT~-

SHAFT
DEFORMED
REINFORCMENT
~1-3-/8-"BAR

1"

~ ~

:::!!: :::!!:

~ ~
............

20"
MAX.

.
1

ANGLE POINT PLAN


ADJUST REINFORCEMENT AS NECESSARY
TO ACCOMODATE ANGLE POINT

=4 1/2"

:::!!:
M

DEFORMED
REINFORCMENT
BAR

......'

BAR"B"
4" (TYP)

END OF PANEL~
~

-1-

./

!I::,

I
I

-~rI

t;;"l

I
\

NOISE SEALER
1/2" (TYP}
.

- / S E E DETAIL@

-L

LIMITS OF TRANSVERSE BARRIER REINFORCEMENT (TYP.)

II

'

--;.

./.

u:
. ' '\

n 1::: :): \-y

-y

1-9!

rn;:::D[

'

ire '"

'

'

-~-

I
/
I

12'- 0"

'"

~-.L-~

TRAFFIC SIDE

NOISEWALL
./.

/----:

I(-)

- ~

'
:

I
I

I ()

END OF PANEL

'

cJ i
,--

12'- 0"

~!&

~-l..-

~SHAFT

,j

'.

I
I

'
'

ll :. .

WEDGE HEAD SHALL BEAR FIRMLY AND UNIFORMLY


A GAINST BASE PLATE. BAR "B" SHALL BE HELD
SEC URE DURING CONCRETE PLACEMENT TO PREVENT
GAPS BETWEEN WEDGE HEAD AND BASE PLATE.

1/4"'
4"

~r;
S1
N

GROUT~ R=3"

OPTIONAL

<t_ SHAFT

~SHAFT

SHEAR-KEY DETAIL

TYPICAL INTERMEDIATE AND END PANEL

END OF PANEL
I

PRECAST CONCRETE WALL


W/ TRAFFIC BARRIER ON
SHAFT FOUNDATION

~4"1
3/4"
CHAMFER
(TYP.)

~SHAFT

NOISE SEALER
1/2" (TYP.)

SET ELEVATION OF
LEVELING NUT BEFORE
SETTING PANEL

1/4" X 3" X 3"


WASHER (TYP.)

TAPERED HOLE FOR

#8 BAR (TYP.)- SEE

1 1/4" ANCHOR BOLT

DETAIL

I"

1/2'~ I"

1' - 0"

BAR"B"
PLATE 1 3/4" x 9" x 1'- 9"
ASTM A 36 GALVANIZED EMBEDDED IN
GROUT. 3/4" CHAMFER ALL CORNERS.

"'I

SLOT 1 3/8" x 1 3/4" FOR


1 1/4" ANCHOR BOLT (TYP.)

-[ -ffi -t?~- ---'


-ffi -~$ - --- ~$ -ffi
io

2" (TYP.}

2"

1'- 5"

~~----~~------1'- 9"

BASE PLATE DETAIL

NOISE BARRIER WALL


TYPE14

1/2"
(TYP.}

STANDARD PLAN D-2.46-00

SEE SHEAR-KEY DETAIL

SHEET 2 OF 2 SHEETS

DETAIL

APPROVED FOR PUBLICATION

Harold J. Peterfeso

----~~~~~~--.......
STATE DESIGN ENGINEER

11-10-05
DATE

fJ'1 Washington State Department of Transportation

NOTES
TYPE14SSA

TYPE14SSB

TYPE14SSC

TYPE14SSD

BAR"A"

BAR"A"

BAR"A"

BAR"A"

6'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

6'- 0"

8'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

8'- 0"

10'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

10'- 0"

12'- 0"

#4@ 15"

#4@ 15"

#4@ 15"

#4@ 15"

12'- 0"

14'- 0"

#4@ 15"

#4@ 11"

#4@ 15"

#4@ 10"

14'- 0"

WALL HT

WALL HT

1. Wall to be designated Noise Barrier Wall Type 14SSA, 14SSB,


14SSC or 14SSD. The Contract specifies actual wall designations.

~
_l_

~
L _ __

16'- 0"

#4@ 10"

#4@ 10"

#4@ 10"

#5@ 12"

16'- 0"

18'- 0"

#4@ 10"

#5@ 12"

#4@ 10"

#5@ 12"

18'- 0"

(RIGHT-OF-WAY

9 1/2"

L __

____J

1-1'- 3

____J

1-1'-31/2'~1

~WALL

0::

#3@ 1'- 3" O.C.


ALTERNATE
SIDES (TYP.)

TRAFFIC SIDE

i.....

SURFACE TREATMENT
AS REQUIRED ~

0
~

CONSTRUCTION JOINT W/
ROUGHENED SURFACE

OPTIONAL 2' - 0"


MIN. SPLICE

HEIGHT MAY VARY IF REQUIRED TO


PROVIDE A SMOOTH PROFILE CONSISTENT
WITH THE ROADWAY PROFILE

7. The Contract specifies actual foundation requirements D1 or D2 .


1'- 8"

1/2" SEAL FULL


HEIGHT (TYP.)

BAR "A" CENTERED ON WALL


SEE CHART FOR BAR SIZE
AND SPACING (TYP.)

WALL TO BE SET
PLUMB (TYP.)

Panels shall have at least 3 feet level ground on each side.

6. The bottom 9" of Bar "B" shall be painted with one coat of Formula
A-6-86 Zinc Dust Oxide Primer OR, one coat of Formula A-11-99
Primer.

3/4" CHAMFER (TYP.)

....1
(.)

3.

5. Anchor Bolts, Nuts, Washers, Base Plate, and Bar B shall have
a Protective Coating of one of the following: Hot Dipped
Galvanizing AASHTO M 232 for Hardware; AASHTO M 111
for Washers and Plates: Mechanical Galvanizing AASHTO M 298
CL 55, or Zinc Rich Paint, Paint threads and nuts after installation.

~WALL

RIGHT-OF-WAY SIDEi

For intermediate wall heights, use the next higher H.

4. All joints shall be in full contact and sealed.

1/2'~1

1 1/4" THREADED ROD


WITH NUTS TOP
& BOTTOM (TYP.)

SEE CONTRACT

2.

3" (TYP.)
PLATE

---j

J
I
Klt'-----'-B-ll

rI

ISOMETRIC VIEW

I
I

SHOWN FOR INSTALLATION

'

1 1/2" (TYP .)

14SSA

B1

80

14SSB

B1

90

14SSC

B2

80

B2

90

1 3/8"
DIAM.

~~ (TYP.)

14SSD

"'i=======i=oo -----r

PLATE

OPTIONAL 2' - 0"


MIN. SPLICE

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

ALTERNATE ANCHOR DETAIL


THREADED ROD WITH NUTS TOP AND BOTTOM

~BARRIER

AND SHAFT

PRECAST CONCRETE WALL W/


SINGLE SLOPE TRAFFIC BARRIER
ON SHAFT FOUNDATION

ANCHOR BOLTS
TOP OF ROADWAY

2" CLR.
#3 SPIRAL
6" MAX.
--~SHAFT
N

c
0:::

~
#4@ 12"

4- #8 BAR "B"

LL.

en
0:::

TOP OF
ROADWAY

J:

(.)

I-

"'"

....
c

@)

0:::

c::
en

LL.

en
'

1 1/4" ANCHOR BOLT. SET BOLTS WITH


TEMPLATE. USE NUTS TOP AND
BOTTOM OF TEMPLATE TO SECURE
LOCATION.

c::

....1

FOR ALTERNATIVE ANCHOR


SEE ANCHOR PLATE DETAIL

6 -#8

...,
TYPICAL SECTION

STANDARD PLAN D-2.48-00

2'- 6"

'II:

NOISE BARRIER WALL


TYPE 14SS

#8 (TYP.)

ANCHOR SPIRAL WITH TWO


TURNS TOP AND BOTTOM

SECTION AT SHAFT SUPPORT

SECTION

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

(20" MAX.)/2

1.5-

SHAFT

~JOINT~

1"
1 3/8"

DEFORMED
REINFORCMENT
BAR

~ ~

:::!!: :::!!:

~ ~
............
Uj>O

20"
MAX.

.
1

ANGLE POINT PLAN


ADJUST REINFORCEMENT AS NECESSARY
TO ACCOMODATE ANGLE POINT

=4 1/2"

:::!!:
M

DEFORMED
REINFORCMENT
BAR
END OF

BAR"B"

PAN~'~'~

1/2" (TYP)

/~tt - - ""'i

,)

-t--

_/_

(~)I

t;;"l

NO IS E

1/2 (TYP.)

-r

,,

'

'"

-"li!

,.'

'
'

_jj_

"'
:c

"

r~)

'

I
/I/
~.EALER
\

'\

II

1["7

LIMITS OF TRANSVERSE BARRIER REINFORCEMENT (TYP.)

......'

'-~

(-,I

" --1..-~

SEE DETAIL@

'\

WEDGE HEAD SHALL BEAR FIRMLY AND UNIFORMLY


AGAINST BASE PLATE. BAR "B" SHALL BE HELD
SECURE DURING CONCRETE PLACEMENT TO PREVENT
GAPS BETWEEN WEDGE HEAD AND BASE PLATE.

TRAFFIC SIDE

NOISEWALL
___________

------------t---.
___./__

-~

'.

12'- 0"

'

'

I ()

(-)!

12'- 0"

GROUT~ R=3"

1/4"1~
----1=

4"

S1

OPTIONAL

<t_ SHAFT

~SHAFT

SHEAR-KEY DETAIL

TYPICAL INTERMEDIATE AND END PANEL

PRECAST CONCRETE WALL W/


SINGLE SLOPE TRAFFIC BARRIER
ON SHAFT FOUNDATION

END OF PANEL

3/4"
CHAMFER
(TYP.)

~SHAFT

NOISE SEALER
1/2" (TYP.)

SET ELEVATION OF
LEVELING NUT BEFORE
SETTING PANEL

1/4" X 3" X 3"


WASHER (TYP.)

~!&
~

1}1/2"

~SHAFT

I
I

'. Ik

I!

'
:

-:-

~E ND OF PANEL

'j_!

----',-

I(-)

--~---------~----

TAPERED HOLE FOR

#8 BAR (TYP.)- SEE

1 1/4" ANCHOR BOLT

DETAIL

I"

1/2'~ I"

1' - 0"

BAR"B"
PLATE 1 3/4" x 9" x 1'- 9"
ASTM A 36 GALVANIZED EMBEDDED IN
GROUT. 3/4" CHAMFER ALL CORNERS.

"'I

SLOT 1 3/8" x 1 3/4" FOR


1 1/4" ANCHOR BOLT (TYP.)

I
I
/

1/2"
(TYP.)

STANDARD PLAN D-2.48-00

SEE SHEAR-KEY DETAIL


2" (TYP.)

2"

SHEET 2 OF 2 SHEETS

1'- 5"

~~--------------1'- 9"

NOISE BARRIER WALL


TYPE 14SS

DETAIL

APPROVED FOR PUBLICATION

Harold J. Peterfeso
STATE DESIGN ENGINEER

BASE PLATE DETAIL

11-10-05
DATE

.....
f

fJ'I
Washington State Department o Transportation

WALL HT
H

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE
16A

B1

16B

80

B1

90

16C

B2

80

16D

B2

90

SOIL TYPE
SOIL
TYPE

CMU

ANGLE OF INTERNAL
FRICTION ~ (DEGREES)

D1

32

D2

38

~RIGHT-OF-WAY

SEE CONTRACT

..,I

CMU
WIDTH

6'- 0"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

8"

16'- 0"

8"

18'- 0"

10"

20'- 0"

DEPTH
D1

DEPTH
D2

3'- 3"

3'- 0"

BAR"D"
#6@ 48"

8'- 0"

8"

#6@ 48"

10'- 0"

8"

#6@ 48"

12'- 0"

8"

#6@ 32"

14'- 0"

10"

#6@ 24"

16'- 0"

10"

4' -7"

3'- 8"

4'- 4"

3'- 10"

4' -7"

4'- 1"

5'- 4"

4'- 10"

4'- 3"

#6@ 48"

#6@ 48"

18'- 0"

10"

6'- 0"

5'- 3"

4'- 9"

#6@ 32"

#6@ 32"

22'- 0"

10"

6'- 8"

5'- 6"

5'- 0"

#6@ 24"

24'- 0"

10"

7'- 4"

5'- 9"

5'- 3"

#6@ 18"

6'- 0"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

DEPTH
D1

DEPTH
D2

3'- 6"

3'- 3"

3'- 9"

3'- 5"

4' -7"

3'- 8"

4'- 4"

3'- 11"

BAR"C"

DEPTH
D1

DEPTH
D2

3'- 8"

3'- 4"

BAR"C"

BAR"D"
#6@ 48"

3'- 8"

4'- 4"

3'- 10"

4'- 8"

4'- 2"

4'- 0"

4'- 11"

4'- 5"

#6@ 40"

#6@ 40"

4'- 8"

5'- 3"

4'- 8"

#6@ 32"

#6@ 32"

10"

5'- 4"

5'- 6"

4'- 10"

#6@ 24"

#6@ 24"

20'- 0"

10"

6'- 0"

4'- 9"

5'- 3"

#7@ 24"

#7@ 24"

#6@ 24"

22'- 0"

10"

8'- 0"

6'- 0"

5'- 6"

#7@ 16"

#7@ 16"

#6@ 18"

24'- 0"

10"

10'- 0"

6'- 3"

5'- 9"

#8@ 16"

#8@ 16"

7. Construction joints in the trench footing shall be spaced at 120


feet maximum.

BAR"C"

BAR"D"

8. See "Masonry Wall Finishes and Details" sheet for masonry


block finishes, special shapes, sizes and layouts.

BAR"D"

WALL HT
H

#6@ 48"

1. Wall to be designated Noise Barrier Wall Type 16A, 168, 16C


or 160. The Contract specifies actual wall designations.

4'- 0"

TYPE 16C
X

#6@ 48"

3'- 6"

CMU
WIDTH

CMU
WIDTH
8"

3'- 4"

NOTES

TYPE 168

6'- 0"

3'- 6"

#6@ 48"
#6@ 40"

TYPE 16D
CMU
WIDTH

DEPTH
D1

DEPTH
D2

3'- 10"

3'- 5"

4'- 2"

3'- 9"

4'- 5"

4'- 0"
4'- 4"

#6@ 48"

#6@ 48"

#6@ 48"

6'- 0"

8"

#6@ 48"

8'- 0"

8"

#6@ 48"

10'- 0"

8"

#6@ 32"

12'- 0"

10"

4'- 0"

4'- 10"

#6@ 48"
#6@ 48"
#6@ 32"

14'- 0"

8"

4'- 8"

4'- 2"

#6@ 24"

14'- 0"

10"

4'- 0"

5'- 3"

4' -7"

#6@ 32"

#6@ 32"

16'- 0"

10"

4'- 0"

4'- 11"

4'- 5"

#6@ 40"

#6@ 40"

16'- 0"

10"

4'- 8"

5' -7"

4'- 11"

#6@ 24"

#6@ 24"

18'- 0"

10"

4'- 8"

5'- 3"

4'- 8"

#6@ 32"

#6@ 32"

18'- 0"

10"

5'- 4"

5'- 10"

5'- 1"

#6@ 18"

#6@ 18"

20'- 0"

10"

5'- 4"

5'- 6"

5'- 0"

#6@ 24"

#6@ 24"

20'- 0"

10"

7'- 4"

6'- 0"

5'- 6"

#7@ 18"

#7@ 18"

22'- 0"

10"

6'- 0"

5'- 9"

5'- 3"

#6@ 16"

#6@ 16"

22'- 0"

10"

9'- 8"

6'- 6"

5'- 9"

#8@ 18"

#8@ 18"

24'- 0"

10"

7'- 8"

6'- 0"

5'- 6"

#7@ 16"

#7@ 16"

24'- 0"

10"

12'- 0"

6'- 9"

6'- 0"

#9@ 18"

#9@ 18"

2. For intermediate wall heights, use the next higher H.


3. All masonry shall be hollow unit and installed as running bond.
4. All masonry is to be specially inspected.
5. All Concrete Masonry Unit (CMU) cells that have vertical steel
reinforcing bars or bond beam units shall be filled with grout.
6.

Panels shall have at least 3 feet of level ground on each side.

9. The Contract specifies actual foundation requirements


D1 or D2.

~ctWALL
!

AND TRENCH

SEE CONTRACT

RIGHT-OF-WAY~

~ctWALL
!

EXPANSION JOINTS @ 24' - 0"


MAX CENTERS. SEE CONTRACT
FOR LOCATIONS

AND TRENCH

BOND BEAM
AT TOP

CMU (TYP.)SEE NOTE 5

4' - 0" MIN. BOND


BEAM AND REINFORCED
EXTENSION AT STEP
CMU (TYP.)SEE NOTE 5

#5@ 4'- 0"


MAX. (TYP.)

MASONRY WALL ON
TRENCH FOOTING

8"

3'- 0" MIN.


J:

BAR"C"

WALL HT
H

3'- 10"

WALL HT
H

=CONCRETE MASONRY UNIT

TYPE 16A

LEVEL (TYP.)

3'- 0" MIN.

r
I

FINAL
GROUND
LINE

::t:

r
I

~ 1MAX.

FINAL
GROUND
LINE

FINAL
GROUND
LINE

O::m

ow
..... 1o
Cz
::cw

1-W

fum

#4 @ ABOUT 18" WITH


2' - 0" MIN. SPLICE CONTINUOUS
THRU EXPANSION JOINT

10"

c
o::m
ow
..... 1o

Cz

::cw

1-W

fum

3" CLR.

NOISE BARRIER WALL


TYPE 16

STANDARD PLAN D-2.60-00


#4 @ ABOUT 18" WITH
2' - 0" MIN. SPLICE CONTINUOUS
THRU EXPANSION JOINT

SHEET 1 OF 2 SHEETS

CONSTRUCTION JOINT
(SEE NOTE 7) SEPARATE
FROM WALL JOINT

APPROVED FOR PUBLICATION

3" CLR.

TYPICAL SECTION
10"WIDECMU

....

Harold J. Peterfeso

1'- 0"

TYPICAL SECTION
B"WIDECMU

ELEVATION

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

BACKER ROD

8" OR 10" CMU

POLYURETHANE
SEALANT
TRAFFIC SIDE

#5 (TYP.)
SEE DETAIL A

DETAIL

PLAN VIEW

TYPICAL EXPANSION JOINT

TYPICAL BOTH SIDES OF WALL

MASONRY WALL ON
TRENCH FOOTING
CELLS WITH VERTICAL
REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

#5@ 4'- 0"


MAX. (TYP.)

10" CMU

8" CMU

BOND
BEAM
UNITS

BOND BEAM
GROUTING LIMIT

'

TRAFFIC SIDE

TRAFFIC SIDE

#5 (TYP.)

PLAN VIEW

NOISE BARRIER WALL


TYPE 16

EXPANSION JOINT AT WIDTH STEP

STANDARD PLAN D-2.60-00

SEE DETAIL A

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

BOND BEAM DETAIL

....

11-10-05
DATE
.
Department of Transportation

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington State

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH}
TYPE
17A

B1

80

17B

B1

90

17C

B2

17D

WALL HT
H

80

B2

90

CMU = CONCRETE MASONRY UNIT

L/~

RIGHT-OF-WAY
SEE CONTRACT

SOLID GROUT CAP


BOND BEAM AT TOP

CMU
WIDTH

6'- 0"

8"

BAR"A"

2'- 0"

3 -#4

2'- 3"

3 -#4

2'- 6"

3 -#4

3'- 0"

4 -#4

3'- 3"

4 -#4

BAR"C"

BAR"D"

BAR"E"

#6@ 48"

#4@ 18"

6'- 0"

8"

#6@ 48"

#4@ 18"

8'- 0"

8"

#6@ 48"

#4@ 18"

10'- 0"

8"

#6@ 48"

#4@ 18"

12'- 0"

10"

#6@ 32"

#4@ 18"

14'- 0"

#6@ 32"

#4@ 18"

16'- 0"

10"

5'- 4"

4'- 9"

5 -#4

#6@ 32"

#6@ 32"

#4@ 18"

#4@ 18"

18'- 0"

10"

6'- 0"

5'- 3"

6 -#4

#6@ 24"

#6@ 24"

#4@ 18"

#6@ 32"

#4@ 18"

20'- 0"

10"

8'- 0"

6'- 0"

5 -#4

#7@ 24"

#7@ 24"

#4@ 18"

#6@ 24"

#6@ 24"

#4@ 18"

22'- 0"

10"

10'- 0"

6'- 3"

5 -#4

#7@ 16"

#7@ 16"

#4@ 12"

#6@ 24"

#6@ 24"

#4@ 18"

24'- 0"

10"

12'- 0"

6'- 9"

5 -#4

#8@ 16"

#8@ 16"

#4@ 12"

5. All Concrete Masonry Unit (CMU}

BAR"D"

BAR"E"

cells that have vertical steel


reinforcing bars or bond beam
units shall be filled with grout.

#6@ 48"

#4@ 18"

#6@ 48"

#4@ 18"

#6@ 24"

#4@ 18"

6'- 0"

4'- 0"

5 -#4

#6@ 48"

#6@ 48"

20'- 0"

10"

6'- 8"

5'- 0"

5 -#4

#6@ 32"

22'- 0"

10"

7'- 4"

5'- 6"

5 -#4

24'- 0"

10"

8'- 0"

6'- 0"

5 -#4
TYPE17C

BAR"C"

BAR"D"

BAR"E"

WALL HT
H

#6@ 48"

#4@ 18"

6'- 0"

8"

#6@ 48"

#4@ 18"

8'- 0"

8"

#6@ 48"

#4@ 18"

10'- 0"

10"

#6@ 40"

#4@ 18"

12'- 0"

10"

CMU
WIDTH

BAR"A"

2'- 6"

3 -#4

3'- 3"

5 -#4

4'- 0"

3'- 6"

5 -#4

4'- 0"

4'- 3"

5 -#4

#6@ 32"

#6@ 32"

#4@ 18"

/~
z

BAR"C"

6'- 0"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

10"

4'- 0"

3'- 9"

5 -#4

#6@ 16"

#4@ 18"

14'- 0"

10"

4'- 8"

4'- 9"

5 -#4

#6@ 24"

#6@ 24"

#4@ 18"

16'- 0"

10"

4'- 8"

4'- 3"

5 -#4

#6@ 40"

#6@ 40"

#4@ 18"

16'- 0"

10"

5'- 4"

5'- 6"

5 -#4

#6@ 16"

#7@ 16"

#4@ 18"

18'- 0"

10"

5'- 4"

4'- 6"

5 -#4

#6@ 32"

#6@ 32"

#4@ 18"

18'- 0"

10"

7'- 4"

6'- 0"

5 -#4

#7@ 24"

#7@ 16"

#4@ 18"

20'- 0"

10"

6'- 0"

5'- 3"

5 -#4

#6@ 24"

#6@ 16"

#4@ 18"

20'- 0"

10"

9'- 8"

6'- 6"

5 -#4

#7@ 16"

#8@ 16"

#4@ 12"

22'- 0"

10"

7'- 0"

5'- 9"

5 -#4

#6@ 16"

#6@ 16"

#4@ 18"

22'- 0"

10"

12'- 0"

7'- 0"

5 -#4

#7@ 16"

#8@ 16"

#4@ 12"

24'- 0"

10"

8'- 0"

6'- 3"

5 -#4

#7@ 16"

#7@ 16"

#4@ 12"

24'- 0"

10"

15'- 0"

7'- 6"

6 -#4

#7@ 16"

#8@ 16"

#4@ 12"

BAR SIZE

SPLICE LENGTH

#6
#7
#8

2'- 8"
3'- 8"
4'- 10"

BAR W/ STANDARD HOOK,


OR PROVIDE FOOTING DOWEL
~ EXCEPT WHEN BARS "C" ARE
REQUIRED

2.

4' - 0" MIN. BOND


BEAM AND REINFORCED
EXTENSION AT STEP

For intermediate wall heights,


use the next higher H.

3. All masonry shall be hollow unit


and installed as running bond.
4. All masonry is to be specially
inspected.

TYPE 17D

8"

::!!:<( _

#4@ 18"
#4@ 18"

10"

CMU (TYP.}SEE NOTE 5


3' - 0" MIN.

#6@ 40"
#6@ 40"

18'- 0"

3 -#4

#4@ 18"

#6@ 40"

5 -#4

3'- 3"

#4@ 18"

#6@ 48"

5 -#4

3'- 9"

3 -#4

#6@ 48"

4'- 3"

5'- 4"

2'- 9"

#4@ 18"

4'- 8"

10"

3 -#4

#6@ 48"

1. Wall to be designated Noise


Barrier Wall Type 17A, 178, 17C
or 170. The Contract specifies
actual wall designations.

10"

16'- 0"

2'- 6"

BAR"E"

4 -#4

8"

3 -#4

3 -#4

BAR"D"

3'- 9"

14'- 0"

2'- 0"

12'- 3"

BAR"C"

4'- 0"

8"

BAR"A"

4 -#4

12'- 0"

BAR"A"

4 -#4

8"

2'- 9"

8"

CMU
WIDTH

3'- 3"

8'- 0"

CMU
WIDTH

NOTES

TYPE 178

WALL HT
H

10'- 0"

WALL HT
H

~
WALLAND
FOOTING

TYPE 17A

6.

Panels shall have at least 3 feet


of level ground on each side.

7.

Construction joints in the


footing shall be spaced at
120 feet maximum.

8.

See "Masonry Wall Finishes and


Details" sheets for masonry
block finishes, special shapes,
sizes and layout.

MASONRY WALL ON
SPREAD FOOTING
LEVEL (TYP.}

TWO BLOCKS MIN.,


THREE BLOCKS MAX.

FINAL GROUND LINE

tO

0::

><

#4@ 18"

2" CLR.

NOISE BARRIER WALL


TYPE 17

CONTINUOUS FOOTING
REINFORCING STEEL BAR "A"
@ EQUAL SPACING WITH
2'- 0" MIN. SPLICE (TYP.}

3" CLR.

BAR "C"- SEE


WALL TABLE

BAR"E"

w
TYPICAL SECTION

SPREAD FOOTING

CONSTRUCTION JOINT
(SEE NOTE 7}

STANDARD PLAN D-2.62-00


EXPANSION JOINTS @ 24' - 0"
MAX CENTERS. SEE CONTRACT
FOR LOCATIONS

ELEVATION

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

BACKER ROD

8" OR 10" CMU

#5@ 4'- 0"


MAX. (TYP.)
POLYURETHANE
SEALANT

1/2" JOINT
TRAFFIC SIDE

#5 (TYP.)

~
::!!:

SEE DETAIL A

PLAN VIEW

TYPICAL EXPANSION JOINT

"'"

BOND
BEAM
UNITS

BOND BEAM
GROUTING LIMIT

DETAIL

TYPICAL BOTH SIDES OF WALL

BOND BEAM DETAIL

MASONRY WALL ON
SPREAD FOOTING
CELLS WITH VERTICAL
REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

3" CLR.

1 __,__,1- ------

(TY.--P_.).......___

10" CMU

8" CMU

1'- 0" MIN. (TYP.)

(!)

--,-----

~~--- --~--------------------------

0
LL

-----r--BAR "A"
(TYP.)
TRAFFIC SIDE

_j

~------'------------1

TRAFFIC SIDE

#5 (TYP.)

NOISE BARRIER WALL


TYPE 17

SEE DETAIL A

PLAN VIEW

FOOTING WIDTH TRANSITION DETAIL

EXPANSION JOINT AT WIDTH STEP

(FOR LOCATIONS WITHOUT FOOTING STEP)


NOTE: TRANSVERSE BARS NOT SHOWN

STANDARD PLAN D-2.62-00


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Harold J. Peterfeso

11-10-05

...... Washington State Department of Transportation


fJ'I

---~s=~=TE=o=Es=IG~NE=N=GIN=E=ER~---

DATE

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

en
z

w
w

a:
[I]

....1
....1

18A

iii

B1

80

18B

B1

90

18C

B2

80

B2

18D

WALL HT
H

90

Cl

TYPE 18A
CMU
WIDTH

BAR"A"

2'- 0"

3 -#4

2'- 3"

3 -#4

2'- 6"

3 -#4

3'- 0"

4 -#4

3'- 3"

4 -#4

SEE CONTRACT

SOLID GROUT CAP


BOND BEAM AT TOP

#6@ 48"

#4@ 18"

6'- 0"

8"

#6@ 48"

#4@ 18"

8'- 0"

8"

#6@ 48"

#4@ 18"

10'- 0"

8"

#6@ 48"

#4@ 18"

12'- 0"

10"

#6@ 36"

#4@ 18"

14'- 0"

#6@ 16"

#4@ 18"

8"
8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

8"

16'- 0"

10"

5'- 4"

3'- 9"

5 -#4

18'- 0"

10"

6'- 0"

4'- 0"

5 -#4

#6@ 48"

#6@ 48"

20'- 0"

10"

6'- 8"

5'- 0"

5 -#4

#6@ 32"

22'- 0"

10"

7'- 4"

5'- 6"

5 -#4

24'- 0"

10"

8'- 0"

6'- 3"

5 -#4

WALL HT
H

RIGHT-OF-WAY

BAR"A"

2'- 0"

3 -#4

2'- 6"

3 -#4

2'- 9"

3 -#4

3'- 3"

3 -#4

BAR"A"

BAR"C"

BAR"D"

BAR"E"

#6 @48"

#4@ 18"

#6 @48"

#4@ 18"

#6 @48"

#4@ 18"

#6 @40"

#4@ 18"

2'- 3"

3- #4

2'- 9"

4- #4

3'- 3"

4- #4

4'- 0"

3'- 9"

4- #4

10"

4'- 8"

4'- 3"

5- #4

#6 @40"

#6 @40"

#4@ 18"

16'- 0"

10"

5'- 4"

5'- 3"

5- #4

#6@ 32"

#6@ 32"

#4@ 18"

#4@ 18"

18'- 0"

10"

6'- 0"

6'- 0"

6- #4

#6@ 24"

#6@ 24"

#4@ 18"

#6@ 32"

#4@ 18"

20'- 0"

10"

8'- 0"

7'- 0"

5- #4

#7@ 24"

#7@ 24"

#4@ 18"

#6@ 24"

#6@ 24"

#4@ 18"

22'- 0"

10"

10'- 0"

7'- 9"

5- #4

#7@ 16"

#7@ 16"

#4@ 12"

#6@ 16"

#6@ 16"

#4@ 18"

24'- 0"

10"

12'- 0"

8'- 6"

5- #4

#8@ 16"

#8@ 16"

#4@ 12"

TYPE 18C
CMU
WIDTH

CMU
WIDTH

BAR"E"

6'- 0"

NOTES

TYPE18B

BAR"D"

8'- 0"

WALL

BAR"C"

WALL HT
H

BAR"C"

WALL HT
H

CMU
WIDTH

BAR"A"

2'- 6"

3- #4

3'- 3"

5- #4

4'- 0"

3'- 6"

5- #4

10"

4'- 0"

4'- 3"

5- #4

14'- 0"

10"

4'- 8"

5'- 3"

16'- 0"

10"

5'- 4"

BAR"E"

#6@ 48"

#4@ 18"

6'- 0"

8"

#6@ 48"

#4@ 18"

8'- 0"

8"

#6@ 48"

#4@ 18"

10'- 0"

10"

#6@ 40"

#4@ 18"

12'- 0"

#6@ 16"

#4@ 18"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

10"

4'- 0"

3'- 9"

5 -#4

16'- 0"

10"

4'- 8"

4'- 3"

5 -#4

#6@ 40"

#6@ 40"

#4@ 18"

BAR"D"

BAR"E"

#6 @48"

#4@ 18"

#6 @48"

#4@ 18"

#6@ 24"

#4@ 18"

#6 @48"

#6@ 32"

#4@ 18"

5- #4

#6@ 32"

#6@ 24"

#4@ 18"

6'- 3"

5- #4

#6@ 24"

#7@ 16"

#4@ 18"

BAR"C"

18'- 0"

10"

5'- 4"

5'- 0"

5 -#4

#6@ 32"

#6@ 32"

#4@ 18"

18'- 0"

10"

7'- 4"

7'- 0"

5- #4

#6@ 16"

#7@ 16"

#4@ 18"

20'- 0"

10"

6'- 0"

5'- 9"

5 -#4

#6@ 24"

#6@ 24"

#4@ 18"

20'- 0"

10"

9'- 8"

8'- 0"

5- #4

#7@ 16"

#8@ 16"

#4@ 12"

22'- 0"

10"

7'- 0"

6'- 6"

5 -#4

#6@ 16"

#6@ 16"

#4@ 18"

22'- 0"

10"

12'- 0"

9'- 0"

5- #4

#8@ 16"

#8@ 16"

#4@ 12"

24'- 0"

10"

8'- 0"

7'- 6"

5 -#4

#7@ 16"

#7@ 16"

#4@ 12"

24'- 0"

10"

15'- 0"

9'- 9"

6- #4

#9@ 16"

#8@ 16"

#4@ 12"

BAR SIZE

SPLICE LENGTH

#6
#7
#8

2'- 8"
3'- 8"
4'- 10"

CMU (TYP.)SEE NOTE 5

For intermediate wall heights,


use the next higher H.

3. All masonry shall be hollow unit


and installed as running bond.

4. All masonry is to be specially


inspected.

5. All Concrete Masonry Unit (CMU)


cells that have vertical steel
reinforcing bars or bond beam
units shall be filled with grout.

6. Panels shall have at least 3 feet


of level ground on each side.

7. Construction joints in the


footing shall be spaced at
120 feet maximum.
8.

See "Masonry Wall Finishes and


Details" sheets for masonry
block finishes, special shapes,
sizes and layout.

CMU = CONCRETE MASONRY UNIT

8"

4' - 0" MIN. BOND


BEAM AND REINFORCED
EXTENSION AT STEP

3'- 0" MIN.

2.

TYPE18D

BAR"D"

6'- 0"

1. Wall to be designated Noise


Barrier Wall Type 18A, 188, 18C
or 180. The Contract specifies
actual wall designations.

MASONRY WALL ON
OFFSET SPREAD FOOTING
LEVEL (TYP.)

OMIT FOOTING DOWEL


~ WHEN BARS "C" PRESENT

~/

/~z
0

TWO BLOCKS MIN.,


THREE BLOCKS MAX.
1

FINAL GROUND LINE

[I]

a:

><

~
b

2" CLR.

NOISE BARRIER WALL


TYPE 18

CONTINUOUS FOOTING
REINFORCING STEEL BAR "A"
@ EQUAL SPACING WITH
2' - 0" MIN. SPLICE (TYP.)
OFFSET SPREAD
FOOTING

3" CLR.

w
TYPICAL SECTION

CONSTRUCTION JOINT
(SEE NOTE 7)

WHEN W IS : < 2' - 6" ....................... CENTER WALL ON FOOTING


2' - 6' ::;. W < 4' - 6" ..... DIM. = 1' - 0"
~ 4' - 6" ........... ............ DIM. = 2' - 0"

STANDARD PLAN D-2.64-01


EXPANSION JOINTS @ 24' - 0"
MAX CENTERS. SEE CONTRACT
FOR LOCATIONS

ELEVATION

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

en
z

w
w

a:
[I]

....1
....1

iii

CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

.B

Cl

1---~.....J ~ . .

,.

8" OR 10" CMU

BACKER ROD

#5@ 4'- 0"


MAX. {TYP.)

..

. .

. ..

t:>

. . />..

I>

t> ....

#5 {TYP.)

t> ....

/>.

TRAFFIC SIDE

::2

BOND
BEAM
UNITS

BOND BEAM
GROUTING LIMIT

PLAN VIEW

..,.'

POLYURETHANE
SEALANT

1/2" JOINT

TYPICAL EXPANSION JOINT

DETAIL

TYPICAL BOTH SIDES OF WALL

CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.
10" CMU

8" CMU

..

..

BOND BEAM DETAIL


.

...
TRAFFIC SIDE

: b ..
;--~

!> " .

,.--2~--;
,1>

,.

MASONRY WALL ON
OFFSET SPREAD FOOTING
.

#5 {TYP.)

TRAFFIC SIDE

SEE DETAIL A

PLAN VIEW

1'- 0" MIN. {TYP.)

3" CLR.
{TYP.)-

EXPANSION JOINT AT WIDTH STEP

- f ____ _

.----'----------'1- - - - - - -

""~~~-

--- ---

-~-

--- ---

-~-

--- ---

-~-

---

1-----~------------BAR"A" _ /
{TYP.)

NOISE BARRIER WALL


TYPE 18
STANDARD PLAN D-2.64-01
SHEET 2 OF 2 SHEETS

FOOTING WIDTH TRANSITION DETAIL


{FOR LOCATIONS WITHOUT FOOTING STEP)
NOTE: TRANSVERSE BARS NOT SHOWN

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

01-06-09
DATE

Washington State Department of Transportation

TYPE 19A

WALL HT
H

CMU
WIDTH

BAR"D"

#0@ 48"

BAR"C"

DEPTH
D2

WALL HT
H

NOTES

TYPE19B

DIAM.

BAR"P"

DEPTH
D1

12"

6 -#5

5'- 3"

4'- 9"

6'- 0"

8"

12"

6 -#5

6'- 0"

5'- 3"

8'- 0"

8"

12"

6 -#5

6'- 9"

5'- 9"

10'- 0"

8"

12"

6 -#5

7'- 3"

6'- 3"

12'- 0"

10"

4'- 0"

#0@ 40"

12"

6 -#6

7'- 9"

6'- 9"

14'- 0"

10"

4'- 8"

#0@ 32"

#0@ 32"

12"

6- #7

8'- 3"

7'- 0"

16'- 0"

10"

5'- 4"

#0@ 24"

CMU
WIDTH

BAR"D"

DEPTH
D2

DIAM.

BAR"P"

12"

6 -#5

6'- 0"

5'- 3"

12"

6 -#5

7'- 0"

6'- 0"

12"

6 -#0

7'- 9"

6'- 9"

12"

6 -#7

8'- 6"

7'- 3"

14"

8 -#7

8'- 6"

7'- 3"

#0@ 24"

14"

8 -#7

9'- 3"

8'- 0"

6'- 0"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

8"

16'- 0"

10"

5'- 4"

#0@ 32"

18'- 0"

10"

6'- 0"

#0@ 48"

#0@ 48"

12"

6 -#8

8'- 9"

7'- 6"

18'- 0"

10"

6'- 0"

#0@ 16"

#0@ 16"

16"

6 -#8

9'- 3"

8'- 0"

20'- 0"

10"

6'- 8"

#0@ 32"

#0@ 32"

12"

6 -#9

9'- 3"

7'- 9"

20'- 0"

10"

8'- 0"

#7@ 16"

#7@ 32"

16"

8 -#7

10'- 0"

8'- 6"

22'- 0"

10"

7'- 4"

#0@ 24"

#0@ 24"

14"

8- #7

9'- 3"

7'- 9"

22'- 0"

10"

10'- 0"

#7@ 16"

#7@ 24"

16"

8 -#8

10'- 6"

9'- 0"

24'- 0"

10"

8'- 0"

#0@ 24"

#0@ 24"

14"

8 -#8

9'- 9"

8'- 3"

24'- 0"

10"

12'- 0"

#8@ 16"

#7@ 16"

16"

8 -#8

11'- 3"

9'- 6"

#0@ 48"
#0@ 48"
#0@ 48"
#0@ 32"

TYPE19C

WALL HT
H

CMU
WIDTH

6'- 0"

8"

8'- 0"

8"

10'- 0"

8"

12'- 0"

8"

14'- 0"

8"

16'- 0"
18'- 0"

BAR"D"

#0@ 48"
#0@ 48"
#0@ 48"
#0@ 40"

BAR"C"

WALL HT
H

#0@ 48"

BAR"C"

DEPTH
D1

#0@ 48"
#0@ 48"

CMU
WIDTH

DIAM.

BAR"P"

DEPTH
D1

DEPTH
D2

12"

6 -#5

5'- 9"

5'- 0"

6'- 0"

8"

12"

6 -#5

6'- 6"

5'- 6"

8'- 0"

8"

12"

6 -#5

7'- 3"

6'- 3"

10'- 0"

10"

4'- 0"

#0@ 24"

12"

6 -#6

7'- 9"

6'- 9"

12'- 0"

10"

4'- 8"

#0@ 32"

12"

6- #7

8'- 6"

7'- 3"

14'- 0"

10"

4'- 8"

DIAM.

BAR"P"

DEPTH
D1

DEPTH
D2

12"

6 -#5

6'- 6"

5'- 9"

12"

6 -#0

7'- 6"

6'- 6"

12"

6 -#7

8'- 3"

7'- 0"

#0@ 32"

14"

8 -#7

8'- 6"

7'- 3"

#0@ 24"

#0@ 24"

14"

8 -#7

9'- 3"

8'- 0"

BAR"D"
#0@ 48"
#0@ 48"

BAR"C"

#0@ 40"

10"

5'- 4"

#0@ 32"

#0@ 32"

14"

8 -#6

8'- 6"

7'- 3"

16'- 0"

10"

5'- 4"

#0@ 16"

#0@ 16"

16"

6 -#8

9'- 6"

8'- 0"

10"

6'- 0"

#0@ 24"

#0@ 24"

14"

8- #7

9'- 0"

7'- 9"

18'- 0"

10"

7'- 4"

#7@ 16"

#7@ 24"

16"

8 -#8

10'- 0"

8'- 6"

20'- 0"

10"

6'- 8"

#0@ 24"

#0@ 16"

14"

8 -#8

9'- 9"

8'- 3"

20'- 0"

10"

9'- 8"

#8@ 16"

#7@ 16"

16"

8 -#9

10'- 9"

9'- 3"

22'- 0"

10"

7'- 4"

#0@ 16"

#0@ 16"

14"

8 -#9

10'- 3"

8'- 9"

22'- 0"

10"

12'- 0"

#8@ 16"

#7@ 16"

16"

8- #10

11'- 6"

9'- 9"

24'- 0"

10"

8'- 0"

#0@ 16"

#0@ 16"

16"

8 -#8

10'- 3"

8'- 9"

24'- 0"

10"

15'- 0"

#8@ 16"

#7@ 16"

18"

8- #10

11'- 6"

9'- 9"

For intermediate wall heights, use the next higher H.

3. All masonry shall be hollow unit and installed as


running bond.
4. All masonry is to be specially inspected.
5. All Concrete Masonry Unit (CMU) cells the have vertical
steel reinforcing bars or bond beam units shall be
filled with grout.
6.

Panels shall have at least 3 feet of level ground on


each side.

7.

Construction joints in the shaft cap shall be spaced


120 feet maximum.

8.

See "Masonry Wall Finishes and Details" sheet for masonry


block finishes, special shapes, sizes and layouts.

9. The Contract specifies actual foundation requirements


01 or 02.
SOIL TYPE

..~~WALL

8"

4' - 0" MIN. BOND


BEAM AND REINFORCED
EXTENSION AT STEP

.. SOLID GROUT CAP


BONDBEAM
AT TOP

~~~

CMU (SEE
NOTE 5}

REINFORCING
STEEL BAR "D"
(CENTERED)

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

SOIL
TYPE

ANGLE OF INTERNAL
FRICTION $ (DEGREES)

D1

32

19A

B1

80

D2

38

19B

B1

90

19C

B2

80

19D

B2

90

RIGHT-OF-WAY
SEE CONTRACT

2.

TYPE19D

5'- 4"

1. Wall to be designated Noise Barrier Wall Type 19A, 198,


19C, or 190. The Contract specifies actual wall
designations.

LEVEL (TYP.)

MASONRY WALL ON SHAFT


WI GRADE BEAM FOUNDATION

TWO BLOCKS MIN.,


THREE BLOCKS MAX.

REINFORCEMENT
NOT SHOWN

NOISE BARRIER WALL


TYPE 19

CONSTRUCTION JOINT
(SEE NOTE 7)

STANDARD PLAN D-2.66-00


REINFORCEMENT
NOT SHOWN

SEE DETAIL A
~SHAFT

SHAFT SPACING 15'- 0" MAX.

1--------------1

TYPICAL SECTION

ELEVATION

'

SHEET 1 OF 2 SHEETS

~SHAFT

SHAFT

5'- 0" MAX.,


1'- 6" MIN.
1/2 ADJACENT SHAFT
SPACING MAX.

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

#5@ 4'- 0"


MAX. (TYP.)

ct.

SHAFT
BACKER ROD
9"

BOND
BEAM
UNITS

HOOKS PARALLEL TO
WALL LAYOUT LINE
BOND BEAM
GROUTING LIMIT

POLYURETHANE
SEALANT

1/2" JOINT

DETAIL

TYPICAL BOTH SIDES OF WALL

BOND BEAM DETAIL

/A\CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

'

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

#4 STIRRUP SPACING @ 12"

3 _ #4 STIRRUP
SPACING @ 6"

'::Hl
fJ+t-lj

kt11

I~

U-f1 ,

rtb
I

r~ >i

8" OR 10" CMU

#4

0)

w
10

(/)

I
N

c
0:::

....
c
J:
ID..

Cl

CONCRETE SHAFT

TRAFFIC SIDE

#5 (TYP.)

1-

:iii

0:::

u.
J:
1(!)

....1

1-

u.
<(

J:

(/)

MASONRY WALL ON SHAFT


WI GRADE BEAM FOUNDATION

SEE DETAIL B

PLAN VIEW

W3.5 SPIRAL
@ 6" PITCH

TYPICAL EXPANSION JOINT

CELLS WITH VERTICAL


REINFORCING AND BOND
BEAMS SHALL BE FILLED
WITH GROUT

EXPANSION JOINT
FILLER PLACED IN
SASH BLOCK RECESSES.

STEP DETAIL
DETAIL

10" CMU

B"CMU

1'- 6"
NOTE
SPIRAL REINFORCEMENT SHALL BE LAPPED
AS SHOWN TO TERMINATE THE ENDS OF THE
SPIRAL REINFORCEMENT (TOP AND BOTTOM).

NOISE BARRIER WALL


TYPE 19

1'- 5" MIN. LAP

STANDARD PLAN D-2.66-00

135 HOOK (TYP.)


TRAFFIC SIDE

TRAFFIC SIDE

#5 (TYP.)

BAR "P" AT EQUAL SPACING


(FOR TOTAL NUMBER SEE
REINFORCEMENT SCHEDULE)

SEE DETAIL B

PLAN VIEW

EXPANSION JOINT AT WIDTH STEP

SECTION

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

------=sT=~=Eo=Es=IG~NE=N=GIN=EE=R------

11-10-05
DATE

fJ'I Washington State Department of Transportation

WIND EXPOSURE & VELOCITY


NOISE
WIND
WIND
BARRIER
VELOCITY
EXPOSURE
(MPH)
TYPE

TYPE20A

NOTES

TYPE20B

WALL HT
H

DEPTH
D1

DEPTH
D2

BAR"A"

BAR"B"

BAR"C"

PILASTER
SPACING
L

WALL HT
H

DEPTH
D1

DEPTH
D2

BAR"A"

BAR"B"

BAR"C"

PILASTER
SPACING
L

6'- 0"

5'- 6"

5'- 0"

6 -#6

4-#4

#5@ 32"

16'- 0"

6'- 0"

6'- 6"

5'- 9"

6 -#6

4-#4

#5@ 32"

16'- 0"

8'- 0"

6'- 6"

5'- 6"

6 -#6

4-#4

#5@ 32"

16'- 0"

8'- 0"

7'- 6"

6'- 6"

6 -#6

4-#4

#5@ 32"

16'- 0"

10'- 0"

7'- 0"

6'- 0"

6 -#6

4-#4

#5@ 32"

16'- 0"

10'- 0"

8'- 6"

7'- 0"

6 -#6

4 -#5

#5@ 32"

16'- 0"

12'- 0"

7'- 9"

6'- 6"

6 -#6

4 -#5

#5@ 32"

16'- 0"

12'- 0"

9'- 3"

7'- 9"

6 -#6

4 -#6

#5@ 32"

16'- 0"

SOIL TYPE

14'- 0"

8'- 3"

7'- 0"

6 -#6

4 -#5

#5@ 32"

16'- 0"

14'- 0"

10'- 0"

8'- 6"

6 -#6

4 -#7

#5@ 32"

16'- 0"

SOIL
TYPE

ANGLE OF INTERNAL
FRICTION $(DEGREES)

16'- 0"

9'- 0"

7'- 6"

6 -#6

4 -#6

#5@ 32"

16'- 0"

16'- 0"

11'- 0"

9'- 0"

6 -#6

6 -#8

#5@ 32"

16'- 0"

18'- 0"

9'- 6"

8'- 0"

6 -#6

4 -#7

#5@ 32"

16'- 0"

18'- 0"

11'- 9"

9'- 9"

6 -#6

6 -#9

#5@ 32"

16'- 0"

D1

32

20'- 0"

10'- 3"

8'- 6"

6 -#6

6 -#7

#5@ 32"

16'- 0"

20'- 0"

12'- 6"

10'- 3"

6 -#7

6- #10

#5@ 32"

16'- 0"

D2

38

22'- 0"

10'- 9"

9'- 0"

6 -#6

6 -#8

#5@ 32"

16'- 0"

22'- 0"

12'- 6"

10'- 3"

6 -#7

6- #10

#5@ 32"

16'- 0"

24'- 0"

11'- 3"

9'- 6"

6 -#6

6 -#9

#5@ 32"

16'- 0"

24'- 0"

12'- 6"

10'- 3"

6 -#7

6- #10

#5@ 32"

12'- 0"

6.

Panels shall have at least 3 feet of level ground on


each side.

WALL HT
H

DEPTH
D1

DEPTH
D2

BAR"A"

BAR"B"

BAR"C"

PILASTER
SPACING
L

7.

See "Masonry Wall Finishes and Details" sheet for masonry


block finishes, special shapes, sizes and layouts.

20A

B1

80

20B

B1

90

20C

B2

80

20D

B2

90

TIE SPACING
BAR"A"SIZE SPACING
6" O.C.

#4
#5

6" O.C.

#6

5"

#7, #8,
#9,#10

1..

o.c.

4" O.C.

RIGHT-OF-WAY
SEE CONTRACT

1. Wall to be designated Noise Barrier Wall Type 20A,


208, 20C, or 200. The Contract specifies actual wall
designations.
2.

3. All masonry shall be hollow unit and installed as


running bond.
4. All masonry is to be specially inspected.
5. All Concrete Masonry Unit (CMU) cells that have vertical
steel reinforcing bars or bond beam units shall be
filled with grout.

TYPE20D

TYPE 20C
WALL HT
H

DEPTH
D1

DEPTH
D2

BAR"A"

BAR"B"

BAR"C"

PILASTER
SPACING
L

6'- 0"

6'- 3"

5'- 3"

6 -#6

4-#4

#6@ 32"

16'- 0"

6'- 0"

7'- 0"

6'- 0"

6 -#6

4-#4

#6@ 32"

16'- 0"

8'- 0"

7'- 0"

6'- 0"

6 -#6

4-#4

#6@ 32"

16'- 0"

8'- 0"

8'- 3"

7'- 0"

6 -#6

4 -#5

#6@ 32"

16'- 0"

10'- 0"

7'- 9"

6'- 6"

6 -#6

4 -#5

#6@ 32"

16'- 0"

10'- 0"

9'- 3"

7'- 9"

6 -#6

4 -#6

#6@ 32"

16'- 0"

12'- 0"

8'- 6"

7'- 3"

6 -#6

4 -#5

#6@ 32"

16'- 0"

12'- 0"

10'- 3"

8'- 6"

6 -#6

4 -#7

#6@ 32"

16'- 0"

14'- 0"

9'- 3"

7'- 9"

6 -#6

4 -#6

#6@ 32"

16'- 0"

14'- 0"

11'- 0"

9'- 3"

6 -#6

6 -#8

#6@ 32"

16'- 0"

16'- 0"

10'- 0"

8'- 3"

6 -#6

4 -#7

#6@ 32"

16'- 0"

16'- 0"

12'- 0"

9'- 9"

6 -#6

6 -#9

#6@ 32"

16'- 0"

18'- 0"

10'- 9"

9'- 0"

6 -#6

6 -#7

#6@ 32"

16'- 0"

18'- 0"

12'- 9"

10'- 6"

6 -#7

6- #10

#6@ 32"

16'- 0"

20'- 0"

11'- 3"

9'- 6"

6 -#6

6 -#8

#6@ 32"

16'- 0"

20'- 0"

13'- 0"

10'- 6"

6 -#7

6- #10

#6@ 32"

14'- 0"

22'- 0"

12'- 0"

10'- 0"

6 -#7

6 -#9

#6@ 32"

16'- 0"

22'- 0"

13'- 0"

10'- 6"

6 -#8

6- #10

#6@ 32"

12'- 0"

24'- 0"

12'- 9"

10'- 6"

6 -#7

6- #10

#6@ 32"

16'- 0"

24'- 0"

13'- 6"

11'- 3"

6 -#8

6- #10

#6@ 32"

12'- 0"

For intermediate wall heights, use the next higher H.

8. The Contract specifies actual foundation requirements


D1 or D2.

..,I

CMU = CONCRETE MASONRY UNIT

(l PILASTER AND SHAFT

MASONRY WALL ON
SHAFT FOUNDATION
32' - 0" MAX. EXPANSION JOINT SPACING
3'- 0" MIN.
1'-33/8"

~I

(l PILASTER

DOWEL - PROVIDE SAME


~ NUMBER & SIZE AS BAR "B".
#4, #5, LAP 2' - 6"
#6 LAP 2'- 10"
#7 LAP 3' - 9"
#8 LAP 4' - 11"
#9 LAP 6'- 3"
#10 LAP 7'- 11"

~PILASTER

PILASTER SPACING L

(l PILASTER

lWO BLOCKS MIN.,


THREE BLOCKS MAX.

uJ

I
I

TOPOFWALL

c?

CMU
PILASTER\
(TYP.)

I
!

/LEV

EL (TYP.)

i
' .

EXPANSION
JOINT

:Z

:iE

Co

ANCHOR SPIRALS
W/lWO TURNS
TOP AND BOTTOM

SECTION AT PILASTER AND SHAFT

a:::

....
c

0
0

CONSTRUCTION JOINT WITH


ROUGHENED SURFACE
DOWEL EMBEDMENT
LENGTH =40 x BAR "B" DIAM.

~L~

@]-, ll[v-

:;, i 0 '

lJ

'"

"'I "I

'Vi

BOTTOM OF WALL _ /

<Vt

If''~

h:- h
V\'-~ f;\'\0 ~Y(0
W-

l';l

FINAL
GROUND
LINE

NOISE BARRIER WALL


TYPE 20
STANDARD PLAN D-2.68-00

SHEET 1 OF 2 SHEETS

--j=

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

ELEVATION

STATE DESIGN ENGINEER

fJ'I Washington

11-10-05
DATE

State Department of Transportation

HORIZONTAL DOWEL - PROVIDE SAME


NUMBER AND SIZE AS BAR "B" LAP 2' - 0" MIN.

#6 x 5' - 0" WITH GREASED OR TAPED


END, PENETRATING PIPE SLEEVE 8" MIN.

TRAFFIC SIDE

BACKER ROD WITH POLYURETHANE


SEALANT - BOTH WALL FACES

EXPANSION JOINT FILLED


WI NOISE SEALER

BAR"C"

1'-33/8"

1 - #5 FULL HEIGHT

2 - #4 FULL HEIGHT (TYP.)

1 - #5 FULL HEIGHT

FILL PILASTER
WI CONCRETE

TRAFFIC SIDE

1 - #5 FULL HEIGHT

BAR"C"

= 0

~I-

SECTION

3/4" DIAM. x 1'- 0" SCHED. 40 PIPE


WITH #6 x 30" GRADE 40 WELDED
TAIL AS SHOWN LAPPED WITH AND
SPACED PER BAR "C"

= 0
~IBAR "B" (TYP.) - FOR QUANTITIES
GREATER THAN FOUR, PLACE
BALANCE ON OUTSIDE
FACES AS SHOWN

(;\A

SECTION

\J

TYPICAL EXPANSION JOINT


1'- 5" MIN. LAP

ct_PILASTER
& SHAFT

PILASTER
REINFORCEMENT

\
W3.5@
4" PITCH
TRAFFIC SIDE

Cl PILASTER
& SHAFT

o- 45"

SECTION

135" HOOK
(TYP.)

NOTE
SPIRAL REINFORCEMENT SHALL BE LAPPED 17" MIN. A 135"
HOOK THAT IS HOOKED AROUND A LONGITUDINAL BAR
SHALL BE USED TO TERMINATE THE ENDS OF THE SPIRAL
REINFORCEMENT AT LAPPED SPLICES AND AT THE TOP AND
BOTTOM OF SHAFT.

MASONRY WALL ON
SHAFT FOUNDATION
FILL TOP
COURSE
WI GROUT
6" CMU
(TYP.)

VERTICAL REINFORCEMENT
BAR "B" #4 @ 4' - 0" MIN.

BAR "C" @ CENTER OF WALL

GROUT ALL CELLS BELOW


GRADE SOLID, MIN. TWO
COURSES (TYP.)

NOISE BARRIER WALL


TYPE 20
BAR"C"

STANDARD PLAN D-2.68-00


SHEET 2 OF 2 SHEETS

4" COMPACTED LEVEL


CRUSHED GRAVEL BASE

SECTION

ANGLE POINT PLAN

APPROVED FOR PUBLICATION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

EXPANSION JOINT

NOTES
1. All rebar shall have a minimum 1 1/2" cover.
2.

See Standard Plan D-2.92 for door and frame details.

3.

See Standard Plan D-2.06 for wall reinforcement not


shown.
5'- 0"

"

BAR "A" (7 BARS

j__~ PER SIDE)

I
I

"

"

b
'
't

CONCRETE SLAB

"

#6 x 11'- 0" (TYP.)


2 PER SIDE OF DOOR

"
48" DOOR OPENING

'

'

#6 x 11'- 0" (TYP.)

!IM
n--r--ANCHOR PIN WELDED
I
TO DOOR FRAME (TYP.)

t!l

WALL

rn

w
w

I-

'
't

CONCRETE SLAB

0::

(.)

ri

t_

GROUND LINE

(.)

CONCRETE SLAB

't
-----

~I

5'- 0"

1-

PLAN VIEW

CONCRETE SLAB DETAIL


"
-~------------------------,,--------------------

"

----------~ - ----------------------------------------------------------------------------------------------------

FRONTVIEW

b
b

b
0

"

0-

"

"

FOR CAST-IN-PLACE WALL


ON OFFSET SPREAD FOOTING

SECTION
WALL

BENDING DIAGRAM
-~

CONCRETE SLAB
GROUND LINE

CONCRETE
SLAB

'

NOISE BARRIER WALL


ACCESS DOOR TYPE 1
STANDARD PLAN D-2.80-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
BAR"A"

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington
ISOMETRIC CUTAWAY VIEW

11-10-05
DATE

State Department of Transportation

J:
I

___,

#5 @ 6'

I
~I

- 8" (TYP )

NOTES

1. All rebar shall have a minimum 1 1/2" cover.

BAR "A" (TYP.)


4" CONCRETE SLAB

3. See Standard Plan D-2.14 for wall reinforcement


not shown.

---------

48" DOOR
OPENING

2'- 6"

2. See Standard Plan D-2.92 for door and


frame details.

25'- 0"

4'- 6"

TOP VIEW

TOP OF TRAFFIC
BARRIER

FINISHED GRADE LINE

OBLIQUE VIEW

I
I

= = =~ =~ ~~~~~~;0~:~ = t_=
DOOR - SEE DETAIL

FRONT VIEW

FOR CAST-IN-PLACE WALL


WI TRAFFIC BARRIER

BAR"A"

USE SPACING IN WALL

'V" PLAN PER WALL HEIGHT

4" CONCRETE SLAB

2'- 9"

FINISHED GRADE
TOP OF
ROADWAY

TOP OF
ROADWAY

NOISE BARRIER WALL


ACCESS DOOR TYPE 2
STANDARD PLAN D-2.82-00

BAR"F"0

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ISOMETRIC CUTAWAY VIEW

BAR"G"0

SECTION

SECTION

Harold J. Peterfeso

.....

STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

BENDING DIAGRAM
-~

#5

II
II

x4

<Li

- 1
-

0" (TYP.)

4 1/2" (TYP.)
#5 X 6

--t.t--

8" (TYP.)

154
~

~C-~
~ 1-4 1/2"

EXPANSION
JOINT

C\\-

94~

t'

I ____

VARIES

11"

(/)

nJ

0::

_L_

_L_

__L

BAR"A"

BAR"B"

-I

VARIES

1-

BAR"C"
1

48" DOOR OPENING

BAR"F"

BAR"G"

0"

ANCHOR PIN WELDED


TO DOOR FRAME (TYP.)
4" CONCRETE SLAB

"

"

"

0
I

l~--~------~----~~1 --~l

~---T-----,r-

11"'
I I "'"'

/ill
// I I

WALL

'=

TRAFFIC SIDE

CONCRETE SLAB DETAIL

-----::------------------------U____________________________________ --------------+LL _____________________ _

FOR CAST-IN-PLACE WALL


W/ TRAFFIC BARRIER
BAR"B"0

DOOR DETAIL
(SEE NOTE 2)

BAR"C"0
TOP OF
ROADWAY

FINISHED GRADE
BAR "A" (TYP.)

ANCHOR PIN (TYP.)

#6

11

1
-

0" (TYP.)

NOISE BARRIER WALL


ACCESS DOOR TYPE 2
STANDARD PLAN D-2.82-00
SHEET 2 OF 2 SHEETS

SECTION

APPROVED FOR PUBLICATION

0
SECTION

Harold J. Peterfeso

11-10-05

...... Washington State Department of Transportation


fJ'I

---~s=~=TE=oE=SIG=N=EN=GIN=EE=R-----

DATE

NOTES

BENDING DIAGRAM

2'- 6"

4'- 6"

2'- 0"

#4 BAR
BAR"A"
BAR"A"

II
~
-~~ /1
I
I"II// I
I
I "'-

~-~-O".e-1
~~ """

3"(TYP.}

:
!

----+- ~-- ------------+----------+----------+----- -------

i=%t ==l----I=---l----

II
----1--Hi
II
_ _j_WJ
r
II
1

EXPANSION
JOINT

I/

3. See Standard Plan D-2.36 for wall reinforcement not shown.


5'- 0"

4" CONCRETE SLAB

BAR"E"

II

4'- 6"

i "-

BAR "A" (7 BARS

tW-~ER SIDE}
48" DOOR OPENING

11-----------------11

II

4" CONCRETE SLAB

~H---

II

II ,

b
'

tl R
: --#6
l x-11'- Or"(TYP.}

II

-~-Wj

~W---

"i illI I
{

~f

2. See Standard Plan D-2.92 for door and frame details.

'

II

-~-Hi
i

#4 BAR

1. All rebar shall have a minimum 1 1/2" cover.

tH-~-

-~-H4
:

4'- 0"

I_!

IIi
II

c;:

t,

-~~~i

/A._

tHT--

5'- 0"

1-

#5 X 4' - 0" (TYP.}

SECTION

-I

~---T-=

: :

I I "'-

""

c;

-N
_____ l____L _______~~,I'{
',,._1__1_~--------------~-==~------

BAR"A"

'

"

'

II

FOR PRECAST WALL ON


SHAFT FOUNDATION

}1---:=----=--------------1

-----" I

\__ BAR"E"

_....J

DOOR FRAME
(SEE NOTE 2}

CONCRETE SLAB NOT SHOWN

DOOR DETAIL
(SEE NOTE 2)
CONCRETE
SLAB
CONCRETE
SLAB

CONCRETE
SLAB

f'

FINISHED
GRADE

FINISHED
GRADE

CONCRETE
SLAB

NOISE BARRIER WALL


ACCESS DOOR TYPE 3

z-:;.1>

"

STANDARD PLAN D-2.84-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SECTION

ISOMETRIC CUTAWAY VIEW

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

/--<~1

/
I

I
___

B"

r-

NOTES

#5 X 6' - B" (TYP )

BAR "A" (TYP.)

:\ __

/'"

_)
-

'''
-

- -

- -

~----

-- --

1. All rebar shall have a minimum 1 1/2" cover.

---- - --

' --

!L
/

2. See Standard Plan D-2.92 for door and frame details.

3. See Standard Plan D-2.44 for wall reinforcement not


shown.

48" DOOR
OPENING
2'- 6"

4'- 6"

5'- 0"

12'- 0"

12'- 0"

TOP VIEW
DOOR- SEE DETAIL

TOP OF TRAFFIC
BARRIER
FINISHED GRADE LINE

---------Li1_______________ L

___________________________________ _

1 MIN.

FRONT VIEW

FOR PRECAST WALL W/


TRAFFIC BARRIER ON
SHAFT FOUNDATION

CONCRETE
SLAB

BAR"A"

DOOR FRAME
(SEE NOTE 2)

2'- 9"

TOP OF
ROADWAY

CONCRETE
SLAB

TOP OF
ROADWAY

TOP OF
ROADWAY

FINISHED
GRADE

ISOMETRIC CUTAWAY VIEW

NOISE BARRIER WALL


ACCESS DOOR TYPE 4
STANDARD PLAN D-2.86-00

BAR "F"

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

SECTION

SECTION

SECTION

STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

4'- 6"

2'- 6"

BENDING DIAGRAM

BAR "A"

~
,

r'~

fl/f-

48" DOOR OPENING

II
I!
--~+-- . .,.
i

,:

1-

,4\J~

tr

:L~
II

#6

'

~-2-

el-

~~ """

11'- 0" (TYP.)

BAR"B"

~~====~

~I

BAR "D"

VARIES

~I

BAR "F"

-~

II :

II
i

0::

~I

~H---

~~~====~~

"'

II
II

---H4
1I
.Jl
"

~~-

VARIES

11"

nJ

(/)

BAR"A"

ll.J__~ER SIDE)

II

---Wj

'------.---

154

EC~-

___ Jjj
i

[TYP.)

'

! ""-

II

4 112"~ I

II
tH--~II
BAR "A" (7 BARS

1\,!

112" [TYP.)

ffi-

II
-/-Hi
II
/

(~\~

#4 BAR

___-%4*---C-I----J~-~J~,/~~J-=-1 =J>s,~k . . .~~


, .. [TYP.)

ExPANsloTN
JOIN

II

-~

L--

4'- 0"

~I/

#4 BAR

BAR"E"

~~
(-t)

~W---

II
l
I>-1++---T-I /A.__ #5
j

4' - 0" (TYP.)

1/

FOR PRECAST WALL W/


TRAFFIC BARRIER ON
SHAFT FOUNDATION
5'- 0"

CONCRETE SLAB NOT SHOWN

DOOR DETAIL
(SEE NOTE 2)

CONCRETE SLAB ___/

b
'

,"

- -

GROUND LINE

WALL

NOISE BARRIER WALL


ACCESS DOOR TYPE 4
STANDARD PLAN D-2.86-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

CONCRETE SLAB DETAIL

Harold J. Peterfeso
- .---=sT=AT=-::E
...
o=Es=IGN=EN=GI=NE=ER___

11-10-05
DATE

fJ'I Washington State Department of Transportation

5'- 0"

NOTES

BENDING DIAGRAM

1. All rebar shall have a minimum 1 1/2" cover.


4" CONCRETE SLAB

2. See Standard Plan D-2.92 for door and


frame details.

-.-b

....'

b
'

"

"

3. See Standard Plan D-2.68 for wall reinforcement


not shown.

"

"
6

WALL
6

BAR "A"

....'
6

4" CONCRETE SLAB

1-

5'- 0"

-I

SOLID GROUT CAP

CONCRETE SLAB DETAIL

CMU

SOLID GROUT CAP


BAR"A"
8" OR 10"

DOOR - SEE NOTE 2


WALL
3" OR5"

#6

FOR MASONRY WALL


(SHAFT FOUNDATION SHOWN)
DOOR OPENING

X 11'- 0" (TYP.}

2 PER SIDE OF DOOR


48" DOOR OPENING

GROUND LINE
CONCRETE SLAB

CONCRETE SLAB

NOISE BARRIER WALL


ACCESS DOOR TYPE 5

II
II

II
II

CONCRETE
SLABS

STANDARD PLAN D-2.88-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

FRONT VIEW

SECTION

....

11-10-05
DATE
.
Department of Transportation

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington State

1'- 0"

"

~"

1'- 0"

1'- 0"

1'- 0"
~

~///

'

ANCHOR PIN - 1/2" x 9" STEEL


WELDED TO REINF OR CEMENT

c.,i

I
'

1'- 0"

1'- 0"

~"

16 GAGE STEEL
DOOR FRAME

....

N
I

'
'

''

'
'
:

'
'

~
-

....
--

. ~~

f-

'
'

lr

n5"0

1'- 0"

-!

"

'

f--

PLATE

1'- 0"

4 1/2" STAINLESS
STEEL HINGE (TYP.) ~I

1 1/2" DOORSTOP

C5 X 9 DOOR FRAME W/
1/2" x 1 1/2" DOOR STOP

WEL D FRAME TOGETHER


INSIDE OF CHANNEL.
GRIN D SMOOTH EXTERIOR
SURFACES BEFORE
PAINTING IF NEEDED.

0
I

DOOR FRAMES MAY


VARY TO MATCH
WALL THICKNESS

'
'

6" x 16" S.S. PLATE


W/10" x 1" DIAM.
S.S. HANDLE

'

!--

io
b

'

''

'

io

F-.
b

,' __

4 1/2" STAINLESS
STEEL HINGE (TYP.) ~

'
'

I==

- - - j-

'
'

'
'

1~

,-'

ANCHOR REINFORCEMENT
~ PLATE (TYP.) -(CHANNEL
WIDTH) x 5" x 1/4", WELDED
TO FRAME

'

'
'

'
'

P"'

'
'

HING E & ANCHOR PIN


REINF ORCEMENT PLATE
y- (TYP.) - (CHANNEL WID TH)
X 12" x 1/4", WELDED T 0
FRAM E

L ___ :

'
'
'

=========-==================================== ===============~---J

1/2" TIE BAR

FRONT VIEW

[l

'

1/2" x 9" ANCHOR PIN

'
'

!-

....
,,,,
,,

'

'

'

l:o
b

....

~
N

6" x 16" S.S. PLATE


W/10" x 1" DIAM.
S.S. HANDLE

'
,-------1

'

_L__

WELDANCHO R
PIN TO HING E
REINFORCEMEN T~p;;
PLATE (TYP.)
'

,-------'
:

1 1/2" DOORSTOP

'
'

GROUND LINE

GROUND LINE

L_

lc"--

SIDE VIEW

[_j~=====7-====-=============== =========-==========-------------==~--:
'

__,__....__,______

1/2" TIE BAR

11 11
11 11

11 1 1
11 1 1

11 11

11 1 1

L! ll~ll !J

SIDE VIEW

FRONT VIEW
NOTE

All exposed metal surfaces shall be painted


with paint conforming to the requirements
in the Standard Specifications, Section 9.

NOISE BARRIER WALL


ACCESS DOOR & FRAME
STANDARD PLAN D-2.92-00
ISOMETRIC VIEW

ALTERNATE ACCESS
DOOR AND FRAME FOR
CAST-IN-PLACE AND
PRECAST WALLS

SHEET 1 OF 2 SHEETS

ISOMETRIC VIEW

ACCESS DOOR AND FRAME


FOR CAST-IN-PLACE AND
PRECAST WALLS

APPROVED FOR PUBLICATION

Harold J. Peterfeso
STATE DESIGN ENGINEER

11-10-05
DATE

....
f

fJ'I
Washington State Department o Transportation

1'- 0"

I
I
'

_l

1'- 0"

1'- 0"

'

1'- 0"

'

.....
-

N
'
HINGE & ANCHOR PIN
~
REINFORCEMENT PLATE
It(TYP.) - (CHANNEL WIDTH) x ~
I'!
12" x 1/4", WELDED TO FRAME

f - - - - -~ f'

.....'

'

Co

'

'

'

Co
b

- - - -

WELDANCHO R
PIN TO HING
REINFORCEMEN
PLATE (TYP .)

i~

f-

~'~1

r- ~

f-----

Co

~-

'

-ll!

'
Co

F-.
b

-----------

WELD FRAME TOGETHER


INSIDE OF CHANNEL.
GRIND SMOOTH EXTERIOR
SURFACES BEFORE
PAINTING IF NEEDED.

C5 x 9 DOOR FRAME W/
1/2" x 1 1/2" DOOR STOP

[l

I
I

ANCHOR BOLT
~ HOLES - 1/2" DIAM.

'

-~---

'

-il!/

-~ f-

1""1

'~

ll- ~

5" x CHANNEL WIDTH x 1/4"

~ REINFORCMENT PLATE

- - --

FOR ANCHORS (TYP.)


WELDED TO FRAME

''' '''
''' ''r''' '''
''

f-

~
N

'

.....
,,,,

"

I
IL ____
L ___ l}- - - - -

1/2" TIE BAR

1 112" DOORSTOP

L__

"'"

~ lj
5"

,------1

I
---------

01

6" x 16" S.S. PLATE


W/10" x 1" DIAM.
S.S. HANDLE

1 1/2" DOORSTOP

-~

-~--

---------

1'- 0"

'll

'

'

4 1/2" STAINLESS
STEEL HINGE (TYP.) ~

'

1'- 0"

~ ~~

L__

'

----------

b
.....'

f-

1'- 0"

-f---

4 1/2" STAINLESS
STEEL HINGE (TYP.) ~

,------1

f - - - - -~ f-

--

1'- 0"

6" x 16" S.S. PLATE


W/10" x 1" DIAM.
S.S. HANDLE

'

16 GAGE STEEL
DOOR FRAME

'

_l

I' ~~ 1112" HOLE FOR ANCHOR~PI-N~~----

""'I

(.,i

'

5" x CHANNEL WIDTH x 1/4"


REINFORCEMENT PLATE W/

./.'\. ~

-+------

GROUND LINE

4---....!:::::======-------l.\!~',L.Lf_

P,

GROUND LINE
11 1 1

11 1 1
11 1 1

~ ll~ll ~

'
'

====-====================================================U ___ J

11 11

11 11
11 11

SIDE VIEW
SIDE VIEW

FRONT VIEW

SEE COUNTERSINK DETAIL

16 GAGE STEEL
DOOR FRAME W/
DOORSTOP

REINFORCEMENT
PLATE

NOISE BARRIER WALL


ACCESS DOOR & FRAME
STANDARD PLAN D-2.92-00
SHEET 2 OF 2 SHEETS

ISOMETRIC VIEW

ALTERNATE ACCESS
DOOR AND FRAME FOR
PRECAST WALLS ONLY

ISOMETRIC VIEW

COUNTERSINK DETAIL

ACCESS DOOR AND


FRAME FOR PRECAST
WALLS ONLY

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

11-10-05
DATE

fJ'I Washington State Department of Transportation

APPROXIMATE FINAL
i
BATTER FOR FACE OF~ :
GEOSYNTHETIC LAYERS
~
'
1 i

rn
z

w
0::
w
m

48~!

....1
....1

iii

NOTES
1. For the values of "L," see sheet 3, and for the values of "Sv" see sheet 2.
2.
TOP GEOSYNTHETIC LAYER

3. "As" is the peak seismic ground acceleration as defined and applied in the AASHTO
LRFD Bridge Design Specifications, Articles 3.1 0.4.1 and 11.6.5.

For Geosynthetic Wall Construction Sequence, see sheet 4 .

4. The long-term geosynthetic design strength "Tal" shall be determined in accordance


with WSDOT Standard Practice T925. See Qualified Products List (QPL), Appendix
"D," for products in which "Tal" has been determined. "H" and "Z" are graphically defined.
"Z" is the distance from the top of the wall to a geosynthetic layer, and is used to determine "Tal" for that layer.

GEOSYNTHETIC
LAYERS (TYP.)

5. "L," the geosynthetic reinforcement length behind the wall face, is graphically defined.
The maximum factored bearing stress acts in the vertical direction at the base of
the wall. The load factors used are as specified in the AASHTO LRFD Bridge Design
Specifications for each specified limit state.
6.

GRAVEL BORROW

FINISHED GRADE
AFTER CONSTRUCTION
OF WALL FACING

~BACKFILL

~
::c

BARRIER ON WALL SEE STANDARD PLAN D-3.15 or D-3.16

1(!)

Fascia or facing type shall be selected from Standard Plans D-3.1 0 or D-3.11
and called out in the Contract Plans. Region is to coordinate with the Geotechnical
Services and Bridge & Structures offices.

iii ~

::c
....1
....1

b
'

WALL FACING (TYP.) SEE STANDARD PLAN


D-3.10 or D-3.11

......
L
GEOSYNTHETIC REINFORCEMENT LENGTH AND
LIMITS OF STRUCTURE EXCAVATION,
WALL BACKFILL AND COMPACTION

FINISHED GROUND
LINE (TYP.)

SECTION DETAIL
KEYNOTES

GEOSYNTHETIC WALL WITH


2 FT TRAFFIC SURCHARGE

GEOTEXTILE FOR UNDERGROUND DRAINAGE CLASS A, MODERATE SURVIVABILITY


(ONLY NEEDED IF A GEOGRID IS USED FOR GEOSYNTHETIC REINFORCEMENT)

I.

TYPE 1, As~ 0.51 g

~ 1'- 0" MIN. GEOTEXTILE OVERLAP, TOP & BOTTOM

TYPE 5, As~ 0.20g

.I

GEOSYNTHETIC WALL
TYPE 3, As~ 0.51g
TYPE 7, As~ 0.20g

::c

PERMANENT
GEOSYNTHETIC WALL
STANDARD PLAN D-3.09-00
SHEET 1 OF 4 SHEETS

I.

GEOSYNTHETIC WALL

.I

I.

.I

GEOSYNTHETIC WALL

TYPE 2, As~ 0.51 g

TYPE 4,

As~

0.51 g

TYPE 6, As~ 0.20g

TYPE 8,

As~

0.20g

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

05117112
DATE

~ Washington State Department of Transportation

rn
z

w
w
m
0::

....1
....1

iii

PERMANENT GEOSYNTHETIC WALL- GEOSYNTHETIC REINFORCEMENT DESIGN

WALL GEOMETRY AND REINFORCEMENT


LAYER LOCATION
TOTAL WALL
HEIGHT, H (ft)

DEPTH BELOW
WALL TOP AT
FACE, z (ft)

5
5
5 < H s. 10
0 to 10
0 to 10
10<Hs.15
0 to 10
10.1 to 15
0 to 10
10.1 to 15
15 < H s. 20
0 to 10
10.1 to 20
0 to 10
10.1 to 20
20 < H s. 25
0 to 10
10.1 to 20
20.1 to 25
0 to 10
10.1 to 20
20.1 to 25
25 < H s. 30
0 to 10
10.1 to 20
20.1 to 30
0 to 10
10.1 to 20
20.1 to 30
30<Hs.35
0 to 10
10.1 to 20
20.1 to 30
30.1 to 35
0 to 10
10.1 to 20
20.1 to 30
30.1 to 35
NOTE: See Note 4, sheet 1.
UPTO 5

LONG-TERM GEOSYNTHETIC REINFORCEMENT STRENGTH REQUIRED, Tal (lbs/ft)*

GEOSYNTHETIC
REINFORCEMENT VERTICAL
SPACING, Sv(ft)

GEOSYNTHETIC WALL
TYPE 1

GEOSYNTHETIC WALL
TYPES2AND4

GEOSYNTHETIC WALL
TYPE3

GEOSYNTHETIC WALL
TYPES

GEOSYNTHETIC WALL
TYPES SANDS

GEOSYNTHETIC WALL
TYPE7

1.0
1.25
1.0
1.25
1.0
1.0
1.25
1.25
1.0
1.0
1.25
1.25
1.0
1.0
1.0
1.25
1.25
1.25
1.0
1.0
1.0
1.25
1.25
1.25
1.0
1.0
1.0
1.0
1.25
1.25
1.25
1.25

505
631
530
660
580
760
730
950
584
992
730
1240
580
1050
1220
730
1310
1530
580
1050
1460
730
1310
1820
580
1050
1510
1690
730
1310
1890
2110

240
300
500
630
620
780
770
980
672
1072
840
1340
720
1180
1350
900
1470
1690
780
1240
1640
980
1550
2050
830
1290
1740
1920
1040
1610
2180
2400

220
280
470
590
570
740
710
920
616
1000
770
1250
660
1100
1270
820
1380
1590
700
1140
1540
870
1430
1920
740
1180
1630
1800
925
1480
2040
2250

505
631
528
660
584
760
730
950
584
992
730
1240
584
1048
1224
730
1310
1530
584
1048
1456
730
1310
1820
584
1048
1512
1688
730
1310
1890
2110

240
300
487
609
586
760
732
950
626
1032
783
1290
667
1128
1304
834
1410
1630
708
1168
1576
885
1460
1970
749
1216
1680
1848
936
1520
2100
2310

220
275
460
575
545
719
681
899
572
976
715
1220
599
1064
1240
749
1330
1550
626
1088
1496
782
1360
1870
653
1120
1584
1752
816
1400
1980
2190

PERMANENT
GEOSYNTHETIC WALL
STANDARD PLAN D-3.09-00
SHEET 2 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

05117112
DATE

~ Washington State Department of Transportation

PERMANENT GEOSYNTHETIC WALL- EXTERNAL STABILITY DESIGN

rn
z

w
0::
w
m
....1
....1

iii

(INCLUDES SEISMIC DESIGN FOR LARGE EARTHQUAKE: AsS 0.51g)


TOTAL
WALL
HEIGHT,
H (ft)

5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

GEOSYNTHETIC WALL TYPE 2

GEOSYNTHETIC WALL TYPE 1


MAX. FACTORED BEARING STRESS (psf)
L (FT)

SERVICE
1

STRENGTH
1

EXTREME
EVENT I

11
11
11
11
11
11
11
11
11
11
11
11
12
13
14
15
15
16
16
17
18
18
19
19
20
21
22
23
24
25
25

847
1081
1248
1415
1582
1768
1916
2083
2250
2417
2650
2751
2918
3085
3252
3412
3586
3753
3920
4087
4268
4421
4588
4755
4922
5123
5256
5423
5590
5757
5863

1220
1566
1800
2034
2268
2531
2736
2970
3204
3438
3783
3906
4140
4374
4608
4835
5076
5310
5544
5778
6038
6246
6480
6714
6948
7238
7416
7650
7884
8118
8251

1011
1388
1685
1982
2279
2609
2873
3170
3467
3764
4198
4358
4655
4952
5249
5424
5843
6140
6437
6734
7040
7328
7625
7922
8219
8698
8813
9110
9407
9704
9874

GEOSYNTHETIC WALL TYPE 3

MAX. FACTORED BEARING STRESS (psf)

EXTREME
EVENT II

L (FT)

SERVICE
1

STRENGTH
1

1192
1949
2165
2381
2597
3278
3029
3245
3461
3677
4176
4238
4325
4541
4757
4927
5189
5405
5621
5837
6027
6269
6485
6701
6917
7148
7349
7565
7781
7997
8080

7
8
9
10
11
11
12
13
14
15
16
17
18
18
19
21
21
22
23
24
25
25
26
27
28
29
30
30
31
32
32

1057
1295
1469
1643
1817
2069
2165
2339
2513
2687
2800
3035
3209
3383
3557
3811
3905
4079
4253
4427
4629
4775
4949
5123
5297
5446
5645
5819
5993
6167
6320

1535
1862
2099
2336
2573
2968
3047
3284
3521
3758
3872
4232
4469
4706
4943
5286
5417
5654
5891
6128
6404
6602
6839
7076
7313
7523
7787
8024
8261
8498
8737

GEOSYNTHETIC WALL TYPE 4

MAX. FACTORED BEARING STRESS (psf)

EXTREME
EVENT I

L(FT)

SERVICE
1

STRENGTH
1

1391
1671
1981
2291
2601
3006
3221
3531
3841
4151
4374
4771
5081
5391
5701
5975
6321
6631
6941
7251
7505
7871
8181
8491
8801
9093
9421
9731
10041
10351
10766

6
7
8
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
23
24
25
26
27
28
29
30
31
32
33
34

852
1028
1203
1378
1553
1738
1903
2078
2253
2428
2607
2778
2953
3128
3303
3476
3653
3828
4003
4178
4375
4528
4703
4878
5053
5244
5403
5578
5753
5928
6112

1168
1415
1657
1899
2141
2394
2625
2867
3109
3351
3590
3835
4077
4319
4561
4787
5045
5287
5529
5771
6032
6255
6497
6739
6981
7228
7465
7707
7949
8191
8425

MAX. FACTORED BEARING STRESS (psf)

EXTREME
EVENT I

L (FT)

SERVICE
1

STRENGTH
1

EXTREME
EVENT I

1284
1598
1890
2182
2474
2811
3058
3350
3642
3934
4216
4518
4810
5102
5394
5621
5978
6270
6562
6854
7230
7438
7730
8022
8314
8632
8898
9190
9482
9774
10035

7
9
10
11
12
14
15
16
18
19
20
22
23
24
25
27
28
29
31
32
33
35
36
37
38
40
41
42
44
45
46

975
1171
1366
1561
1756
1951
2146
2341
2536
2731
2924
3121
3316
3511
3706
3899
4096
4291
4486
4681
4873
5071
5266
5461
5656
5848
6046
6241
6436
6631
6823

1343
1613
1882
2151
2420
2685
2958
3227
3496
3765
4029
4303
4572
4841
5110
5371
5648
5917
6186
6455
6716
6993
7262
7531
7800
8057
8338
8607
8876
9145
9403

1473
1756
2058
2360
2662
2947
3266
3568
3870
4172
4494
4776
5078
5380
5682
5965
6286
6588
6890
7192
7519
7796
8098
8400
8702
8988
9306
9608
9910
10212
10544

NOTE: See General Note 5, sheet 1.

PERMANENT GEOSYNTHETIC WALL- EXTERNAL STABILITY DESIGN


(INCLUDES SEISMIC DESIGN FOR LARGE EARTHQUAKE:
TOTAL
WALL
HEIGHT,
H (ft)

5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

GEOSYNTHETIC WALL TYPE 6

GEOSYNTHETIC WALL TYPE 5


MAX. FACTORED BEARING STRESS (psf)
L (FT)

SERVICE
1

STRENGTH
1

EXTEME
EVENT I

11
11
11
10
10
10
10
10
11
11
11
12
12
13
14
14
15
16
17
18
18
19
19
20
21
21
22
23
24
25
25

847
1105
1273
1441
1609
1768
1945
2113
2281
2449
2711
2785
2953
3121
3289
3522
3625
3793
3961
4129
4325
4465
4633
4801
4969
5123
5305
5473
5641
5809
5918

1220
1607
1843
2079
2315
2531
2787
3023
3259
3495
3884
3967
4203
4439
4675
5015
5147
5383
5619
5855
6131
6327
6563
6799
7035
7238
7507
7743
7979
8215
8341

992
1320
1553
1786
2019
2229
2485
2718
2951
3184
3516
3650
3883
4116
4349
4642
4815
5048
5281
5514
5763
5980
6213
6446
6679
6881
7145
7378
7611
7844
7998

NOTE: See Note 5, sheet 1.

EXTEME
EVENT II

SERVICE
1

STRENGTH
1

1192
1688
2090
2463
2808
3278
3424
3699
3954
4190
4396
4616
4809
4990
5163
5201
5489
5646
5801
5955
6146
6272
6438
6611
6793
7148
7192
7412
7649
7904
8177

6
6
6
7
7
7
8
9
10
11
11
12
12
13
14
14
15
16
17
18
18
19
19
20
21
21
22
23
24
25
25

1057
1358
1569
1780
1991
2266
2413
2624
2835
3046
3245
3468
3679
3890
4101
4326
4523
4734
4945
5156
5417
5578
5789
6000
6211
6577
6633
6844
7055
7266
7311

1535
1928
2226
2527
2831
3372
3445
3755
4066
4378
4598
5004
5316
5628
5939
6125
6557
6863
7166
7466
7683
8057
8346
8631
8912
9408
9457
9720
9978
10229
10373

0.20g)

GEOSYNTHETIC WALL TYPE 7

MAX. FACTORED BEARING STRESS (psf)


L (FT)

As~

GEOSYNTHETIC WALL TYPE 8


MAX. FACTORED BEARING STRESS (psf)

MAX. FACTORED BEARING STRESS (psf)

EXTREME
EVENT I

L (FT)

SERVICE
1

STRENGTH
1

1294
1574
1889
2211
2540
2776
3213
3555
3901
4249
4737
4948
5297
5644
5990
6321
6672
7006
7335
7657
7891
8280
8578
8866
9144
9515
9664
9905
10131
10343
10550

6
6
6
7
7
7
8
9
10
11
11
12
12
13
14
14
15
16
17
18
18
19
19
20
21
21
22
23
24
25
25

852
1107
1302
1497
1692
1924
2082
2277
2472
2667
2886
3057
3252
3447
3642
3848
4032
4227
4422
4617
4810
5007
5202
5397
5592
5773
5982
6177
6372
6567
6735

1168
1536
1809
2082
2355
2692
2901
3174
3447
3720
4037
4266
4539
4812
5085
5383
5631
5904
6177
6450
6729
6996
7269
7542
7815
8075
8361
8634
8907
9180
9421

EXTREME
EVENT I

L(FT)

SERVICE
1

STRENGTH
1

EXTREME
EVENT I

1155
1560
1842
2124
2406
2773
2970
3252
3534
3816
4159
4380
4662
4944
5226
5546
5790
6072
6354
6636
6932
7200
7482
7764
8046
8319
8610
8892
9174
9456
9705

6
6
6
7
7
7
8
9
10
11
11
12
12
13
14
14
15
16
17
18
18
19
19
20
21
21
22
23
24
25
25

977
1278
1504
1730
1956
2228
2408
2634
2860
3086
3342
3538
3764
3990
4216
4456
4668
4894
5120
5346
5570
5798
6024
6250
6476
6684
6928
7154
7380
7606
7798

1349
1786
2105
2424
2743
3145
3381
3700
4019
4338
4718
4976
5295
5614
5933
6291
6571
6890
7209
7528
7863
8166
8485
8804
9123
9436
9761
10080
10399
10718
11009

1326
1868
2214
2560
2906
3381
3598
3944
4290
4636
5072
5328
5674
6020
6366
6762
7058
7404
7750
8096
8453
8788
9134
9480
9826
10143
10518
10864
11210
11556
11834

PERMANENT
GEOSYNTHETIC WALL
STANDARD PLAN D-3.09-00
SHEET 3 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

05117112
DATE

~ Washington State Department of Transportation

NOTES(SHEEn

rn
z
w
0::
w
m

1. Use of the Temporary Form System, as detailed in this plan, is optional.


SEE TEMPORARY FORM SYSTEM DETAIL, THIS SHEET

....1
....1

~elp main_tain the wa~l face batter, leave the form system for the precedln~ layer 1n place wh1le constructing the next layer. When the upper
layer IS complete, remove the form system from the lower layer and

2. To

iii

1. SET FORM ON COMPLETED LIFT.

reset it for the next layer. See below.

GEOTEXTILE

GEOSYNTHETIC

TAIL

... .-.:.... --- .. :-.._. ... -..

2. UNROLL GEOSYNTHETIC AND POSITION IT


SO THAT A 4'- 0" WIDE "TAIL" DRAPES OVER
THE FORM. IF A GEOGRID IS USED FOR THE
GEOSYNTHETIC REINFORCEMENT, POSITION
GEOTEXTILE TO PREVENT BACKFILL FROM
SPILLING THROUGH GEOGRID OPENINGS.

3. PLACE THE BACKFILL UNTIL THE BACKFILL


IS UP TO HALF OF THE REQUIRED VERTICAL
GEOSYNTHETIC LAYER SPACING.

WINDROW

rnw

0::~
z_.

1" THICK PLYWOOD


OR TIMBER PLANKS
- CONTINUOUS

Wu.

I-_.
4. PLACE A WINDROW TO SLIGHTLY
GREATER THAN FULL LIFT HEIGHT
AGAINST THE FORM.

W<(

~~

coe>
Oz

1-Q

~~

.,.,. ,. ,. . . .,. . . .

9~',

1" I.D. PIPE


3/8" STEEL STRAP
5. PLACE THE GEOSYNTHETIC "TAIL" OVER
THE WINDROW AND LOCK INTO PLACE
WITH BACKFILL.

~T---------~~~

I.

2' -7"

PLAN

6. COMPLETE BACKFILLING UNTIL THE COMPACTED BACKFILL LAYER THICKNESS IS


EQUAL TO THE REQUIRED VERTICAL
GEOSYNTHETIC LAYER SPACING.

11
>
rn
3/8" STEEL STRAP \

.. ..:,.:, ... ; ...-..:.

.. .. .. __ ...-._.:._:__.:-_ .. :.-

'

. ......... .. : _ ~ .: .. .

7. THE FORM MAY BE LEFT IN PLACE WHILE


CONSTRUCTING THE NEXT LAYER {SEE
NOTE 2) OTHERWISE, RESET THE FORM
AND REPEAT THE SEQUENCE.

7/8" DIAM. STEEL PIN


{WELDED TO STEEL STRAP)

1
"

------:f

===~\~~-_j_
WOOD WEDGE TO SUPPORT
AND ALIGN STRAP

PERMANENT
GEOSYNTHETIC WALL
STANDARD PLAN D-3.09-00

GEOSYNTHETIC WALL CONSTRUCTION SEQUENCE

ELEVATION

SHEET 4 OF 4 SHEETS

{SECTION VIEW)

TEMPORARY FORM SYSTEM DETAIL

APPROVED FOR PUBLICATION

___~_a_sc=o==B=ak=o~t~re~h~U~1 ___ 05fl7fl2


......

STATE DESIGN ENGINEER

DATE

~ Washington State Department of Transportation

en
z

FOR THE VALUES OF "X",


SEE STANDARD PLAN D-3.09, SHEET 1.

w
w

0::

48
1
APPROXIMATE FINAL
BATTER FOR FACE OF ~ 1 j
GEOSYNTHETIC LAYERS

III
....1
....1

FILL MATERIAL
SPECIFIED
ELSEWHERE
IN CONTRACT

"'i

iii

NOTES
FOR WALLS WITHOUT TRAFFIC BARRIER, OR
WHERE THE TRAFFIC BARRIER IS AT GRADE,
USE THE DETAILS SHOWN ABOVE THE MATCH
LINE ON THIS SHEET

{l

FOR WALLS WITH SINGLE SLOPE TRAFFIC


BARRIER. USE THE DETAILS ABOVE THE
MATCH LINE ON STANDARD PLAN D-3.15

G)#4

3'- 0"

1. All bars shown on this plan shall be ASTM A706


unless otherwise specified in the Contract.

2. Safety cable or fence required when "H";?: 10'- 0".


3. All cast-in-place concrete shall be class 4000.

FOR WALLS WITH F-SHAPE TRAFFIC BARRIER


USE THE DETAILS ABOVE THE MATCH LINE ON
STANDARD PLAN D-3.16

\V =EPOXY COATED

::::i

MATCH LINE
3;
-------:z:

#4

WELDED WIRE FABRIC FOR


CONCRETE REINFORCEMENT
4" X 4" - W2.9 OR 6" X 6" - W4.0
- COMPLY WITH AASHTO M55

~
b

@#4 (TYP.)

4' - 0" (LEVEL)

SHOTCRETE FACING
EXCESS SHOTCRETE - REQUIRED
TO COMPENSATE FOR FACE
BULGING AND VARIATIONS WITHIN
FACING TOLERANCE

SHOTCRETE DETAIL

FOR THE VALUES OF B,


-SEE TABLE

@ #4 W/ 2' - 0" MIN.

SPLICE

TYPICAL SECTION

PERMANENT GEOSYNTHETIC RETAINING WALL


WITH CAST-IN-PLACE CONCRETE FASCIA

IIHII
(ft.)

ROWSOF#4\V
DOWEL BARS
REQUIRED
N
(no.)

FASCIA
FOOTING
WIDTH
B
(ft. -in.)

UP T05
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

2
3
3
3
3
4
4
4
4
4
6
6
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'-01/2"
1'-01/2"
1' - 1"
1' - 1"
1'- 2"
1'- 2"
1'-21/2"
1'-21/2"
1'- 3"
1'- 3"
1'-31/2"
1'-31/2"
1'- 4
1'- 4"
1'- 5"
1'- 5"
1'-51/2"
1'-51/2"
1'- 6"
1'- 6"
1'-61/2"
1'-61/2"
1'- T'
1'- 7"
1'- 8"

1- "B"- 4" I

#4

GEOSYNTHETIC
LAYERS (TYP.)
FINISHED
GRADE

DESIGN
HEIGHT

11

SHOTCRETE FACING
SEE SHOTCRETE DETAIL

KEYNOTES

0
0

"N" ROWS OFG)#4\VDOWEL REINFORCEMENT PLACE BETWEEN GEOSYNTHETIC LAYERS


AT 5'- 0" O.C. HORIZONTAL SPACING, SEE TABLE. VERTICAL SPACING BETWEEN ROWS TO
BE EQUAL, AS MULTIPLES OF "Sv" ALLOW. ROWS MAY BE STAGGERED. SEE STD. PLAN
D-3.09 FOR "Sv"
INCREASE THE COVER AS REQUIRED TO ACCOMMODATE ARCHITECTURAL FEATURES
AND FINISH.

~ CONSTRUCTION JOINT WITH ROUGHENED SURFACE.

GEOSYNTHETIC
LAYERS (TYP.)
FINISHED
GRADE

4' - 0" (LEVEL)

~ 3" I.D. PVC PIPE FOR WEEP HOLE IN WALL FACING - PLACE BETWEEN GEOSYNTHETIC
LAYERS APPROX. 9" DEEP AT 12'- 0" HORIZONTAL SPACING. LENGTH TO EXTEND TO
OUTER SURFACE OF SPECIFIED WALL. WEEP HOLES SHALL BE KEPT CLEAR OF
CONCRETE. SEE STANDARD PLAN D-3.09, FOR DETAILS NOT SHOWN.

~ VERTICAL CONSTRUCTION JOINTS IN FASCIA @ 24' - 0" O.C. WITH 1/2 " PREMOLDED JOINT
FILLER (SEE STANDARD PLAN D-10.45, "SPLIT ELEVATION").

~ VERTICAL CONSTRUCTION JOINTS IN FOOTING @ 120' O.C. MAX. (SEE STANDARD PLAN

1-

::c

CAST-IN-PLACE PERMANENT
GEOSYNTHETIC WALL
FASCIA AND FACING
STANDARD PLAN D-3.10-01

C!>Z
iii~

::c
_.a
....1

'

~C\1

#.

SHEET 1 OF 1 SHEET

D-10.45, "ELEVATION"). IF THE FOOTING IS STEPPED, PROVIDE 2'- 0" NON-CONTACT LAP
SPLICES FOR THE@ #4 BARS AT EACH STEP.
(/) COORDINATE WALL FINISH AND CONFIGURATION WITH STATE BRIDGE AND STRUCTURES
ARCHITECT PER WSDOT DESIGN MANUAL 730.04(5).

~ THE@) BARS AND INTERIOR@ BARS SHALL BE USED ONLY IF THE FACE IS VERTICAL.

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

TYPICAL SECTION

PERMANENT GEOSYNTHETIC RETAINING WALL


WITH SHOTCRETE FACING

......

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

NOTES

en
zw

1. All structural steel shall be ASTM A572 GR. 50


or ASTM A588 or as otherwise noted.

0::

Ill
....1
....1

iii

"B" BRIDGE APPROACH SLAB


{SEE BRIDGE PLANS) OR
PERMANENT GEOSYNTHETIC
WALL BARRIER- SEE STANDARD
PLANS D-3.15 OR D-3.16

''L'' + ''T'' + 7 11 8

FRONT FACE OF RETAINING WALL


AND CONCRETE FASCIA PANEL

MAY BE EXTENDED IN
LIEU OF CABLE FENCE,
3' -6" MAX.

2. Anchor Rods shall be ASTM F1554 GR. 55


SAFETY CABLE OR FENCE
REQUIRED WHEN "H" ~ 10'- 0"
-CONTACT BRIDGE DESIGN OFFICE

3. All cast-in-place concrete shall be Class 4000.

TRAFFIC BARRIER ON BRIDGE APPROACH SLAB {SEE BRIDGE PLANS)


OR PERMANENT GEOSYNTHETIC WALL BARRIER- SEE STANDARD
PLANS D-3.15 OR D-3.16

= -1.
,z

AP

4@# 5 CONT. {TYP.


TOP AND BOTTOM)

...-''.I!-

,, I

~~

FILL MATERIAL SPECIFIED


ELSEWHERE IN CONTRACT

II

(!)

w
I

:Z = .
-ox
:::!!:

iO

<

~:::!!:

3"DIAM. PVC
SCHEDULE 40 PIPE

....1
....1

:c=

7/8" DIAM. GALV. R_QD


ENCASED IN PVC<.y

---.-------(<) - - - - - - - - j

en
=
WCl

en>

u>-

~~

FRONT FACE OF RETAINING


WALL - PRECAST CONCRETE
FASCIA PANEL

Iw

TYPICAL SECTION

1-(.)

0~

Ill

II
(!)

w
I
....1
....1

~
~

.w

UO

ow
.z

1/4" <I> SLOT


{TYP.)

TACK WELD
& GALV. {TYP.)

PERMANENT GEOSYNTHETIC WALL


PRECAST CONCRETE FASCIA PANEL

MAY USE STAY IN


PLACE FORMWORK

OUTSIDE FACE OF
EXTERIOR WEB
WIRE GAGE# 6 GALV.
AFTER FABRICATION
{TYP.)

~;j

:::i!:w
= 0
co-

,en

1" (TYP.) BEND DOWN


WHEN IN PLACE

KEYNOTES

- I..... =:I

@)0

GEOSYNTHETIC REINFORCEMENT

-.;tl-

'lt~

u.
..-u.
..... 0

7/8" DIAMETER THREADED ROD {STANDARD SPECIFICATION


SECTION 9.06.5 (4)), GALVANIZED AFTER FABRICATION IN ACCORDANCE
WITH AASHTO M232. RODS SHALL BE THREADED A MINIMUM OF 1'- 0" AT
ENDS. PLACE LEVEL AND NORMAL TO WALL. ENCASE RODS WITH PVC
SLEEVE. EMBED PVC ENDS INTO GRADE BEAM AND EDGE BEAM.

WEEP HOLE ASSEMBLY

~ BACKFILL VOID BEHIND WALL WITH SAND CONFORMING TO STANDARD


SPECIFICATION SECTION 9-03.13(1) TO 6" ABOVE FINISHED GRADE ON
FRONT FACE OF WALL.

~ LEVELING PAD, EDGE BEAM, AND GRADE BEAM ARE CAST-IN-PLACE


CONCRETE PLACED AT 6H : 1V MAXIMUM SLOPE AND THE VERTICAL
CONSTRUCTION JOINTS SHALL BE SPACED AT 120' MAXIMUM.

0
10% WALL HEIGHT
"H" {2'- 0" MIN.)

"L"

=GEOSYNTHETIC REINFORCEMENT LENGTH


AND WALL BACKFILL AND COMPACTION

LOCATION DIMENSIONED IN BRIDGE FOUNDATION


PLAN IF ADJACENT TO A BRIDGE
LIMITS OF STRUCTURE EXCAVATION CLASS B INCL. HAUL

ONE 3" DIAMETER WEEP HOLE PER FASCIA PANEL. HORIZONTAL


LOCATION AT THE CENTERLINE FASCIA PANEL.

~ALL VERTICAL PANEL JOINTS SHALL BE SEALED FOR FULL CONTACT


WITH AN APPROVED JOINT SEALANT. SEE "EXPANSION JOINT DETAIL",
SHEET2.

~ UNLESS OTHERWISE SHOWN, MINIMUM CONCRETE COVER FOR


REINFORCEMENT IS 1 1/2". INCREASE COVER AS REQUIRED TO
ACCOMMODATE ARCHITECTURAL FEATURES.

<!/) IF GRADE BEAM IS NEAR CENTERLINE OF ROADWAY, USE ONE GRADE


BEAM AT CENTERLINE FOR FASCIA PANEL ON EITHER SIDE.
TYPICAL SECTION

PERMANENT GEOSYNTHETIC RETAINING WALL WITH


PRECAST CONCRETE FASCIA PANEL AND TRAFFIC BARRIER

~ CONTACT BRIDGE OFFICE FOR ROADWAY CROSS SLOPES GREATER

PRECAST PERMANENT
GEOSYNTHETIC WALL
FASCIA
STANDARD PLAN D-3.11-02
SHEET 1 OF 2 SHEETS

THAN 0.08'/FT.

~ COORDINATE WALL FINISH AND CONFIGURATION WITH STATE BRIDGE


AND STRUCTURES ARCHITECT PER WSDOT DESIGN MANUAL 730.04(5).

~ SEE PRECAST FASCIA TABLE, SHEET 2 OF 2.

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

FACE OF GEOSYNTHETIC REINFORCEMENT

en
zw
0::
w

PRECAST FASCIA TABLE

6"

EQUAL SPACING
DESIGN
HEIGHT
"H"
(ft.)

Ill
....1
....1

iii

PANEL
THICKNESS
nyn

1' -7"

6"

1" (TYP.)

(F 10)
BAR
SPACING

(in.)

PLACE AND LEVEL


WALL PANELS ON
STEEL SHIMS. FILL
RECESS WITH
GROUT AFTER
PLACING AND
LEVELING WALL
PANELS

usn

(in.)

2 CD# 4 - 4" SPACING


@ EACH ANCHOR ROD

6.0

18.0

6.0

18.0

6.0

18.0

1 1/2"

6.0

18.0

CLR.

6.0

18.0

10

6.0

18.0

11

6.0

18.0

12

6.0

18.0

13

6.0

18.0

14

6.0

18.0

15

6.0

18.0

16

6.0

18.0

17

6.0

18.0

18

6.0

18.0

19

6.0

18.0

20

6.0

18.0

21

6.0

18.0

22

7.0

18.0

23

7.0

18.0

24

7.0

18.0

25

8.0

18.0

26

8.0

18.0

27

8.0

18.0

28

9.0

12.0

29

9.0

12.0

30

9.0

12.0

31

10.0

12.0

32

10.0

12.0

33

11.0

12.0

34

11.0

12.0

11.0

35

3/4" X 3" X 3" PLATE WASHER


WITH HEX NUT, EACH SIDE

<'-I

3/4" X 3" X 3" PLATE WASHER


WITH HEX NUT, EACH SIDE

@#4CONT.
(TYP.)

(j)#4@
o.c.

4 # 4 TIE@ 1'- 6" O.C.

-'-'-------+---'-----t-CIIl

1'- 0"

4 @ # 4 CONT. (TYP.)

2@#4-4"SPACING@
EACH ANCHOR ROD

>
en

5 #4 CONT.
2 SPACES@ 9" 1'- 6"

1'- 0"

2'- 0"

GRADE BEAM

LEVELING PAD

@#4@EACH
ANCHOR ROD
@#4@ 1'-6"

DETAIL

DETAIL

EDGE BEAM

DETAIL

ct> 4" x 4" SHIM STACK


(2 LOCATIONS PER PANEL)
HEIGHT SHALL BE ADJUSTED SO THAT
VERTICAL PANEL JOINTS ARE PLUMB

FRONT FACE OF PRECAST


CONCRETE FASCIA PANEL

=FASCIA PANEL WIDTH

"W"

VOID BEHIND PANEL


GEOSYNTHETIC WALL
-FOLD GEOTEXTILE TO FIT AT FAR
FACE OF CURTAIN WALL & CONCRETE
FASCIA PANEL INTERSECTION

7/8" DIAM. GALV. ROD@ 4'- 0' SPACING MAX.


PRECAST CONCRETE
FASCIA PANEL

]~

~--+---~-~~~~~~~~_L~~~~~~-~~~~~

. ..

. . ..

~~---~+.-.--~-.~-~~.--~~.--~~~-.~.-.-~+-.-.-~-~~-.~-~-+-~-~-.~
~

. A. .'

12.0

. A.

GRADE BEAM

A .

'

GRAVEL BORROW BACKFILL


-SHALL BE SAME MATERIAL
USED IN GEOSYNTHETIC WALL

<(

...J>
~~

GEOSYNTHETIC REINFORCEMENT

3:::::!:

~en

<(Z

~0

0::-

PLAN VIEW

::Jen

uz
w

TYPICAL PANEL LAYOUT

::::!:

e.

PANEL WIDTH "W" SHOWN IN ELEVATION OF RETAINING WALLS

GRAVEL BACKFILL FOR


WALL- SEE DRAINAGE
DETAIL FOR LIMITS

FASCIA PANEL BENDING DIAGRAM


MARK

SIZE

LENGTH

CD

2'- 0"

STR.

CD

4'- 0"

STR.

1'- 9"

STR.

G)

4'- 11"

(A)

2'- 1 3/4"

STR.

(j)

(A)

STR.

(A)

STR.

@)
@

(A)

STR.

ALL REINFORCEMENT SHALL


BE ASTM A706.
(A) DETERMINE FROM PLANS

~"
/
G)

~rl
.
;....
Co

(A)

STR.

#4

ABUTMENT WALL

1'- 9"

I
I

I
I

I
-

ALL DIMENSIONS ARE


OUT TO OUT

EXPANSION JOINT
1/2" MIN. TO 3/4" MAX.

(j)

#4
8"

BACKER ROD

~
....

:
--

1'- 0"

PRECAST PERMANENT
GEOSYNTHETIC WALL
FASCIA
STANDARD PLAN D-3.11-02
SHEET 2 OF 2 SHEETS

APPROVED FOR PUBLICATION


POLYURETHANE
SEALANT

PLAN VIEW

WALL TRANSITION
EXPANSION JOINT DETAIL

GEOSYNTHETIC WALL TO CURTAIN WALL TRANSITION


AT BRIDGE- SEE BRIDGE PLAN SHEETS FOR DETAILS

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

KEYNOTES
MOMENT SLAB CONSTRUCTION JOINT SPACING@ 120' - 0" MAX
1

en
z

w
0:::
w

EXP. JOINT Cf.

BARRIER EXPANSION JOINT

Ill

(SEE TABLE)

....1
....1

BARRIER DUMMY JOINT SPACING

iD

~
7'

\ _ DUMMY JOINT (TYP.)


(SEE DETAIL) ~

TERMINUS

BARRIER DUMMY JOINT SPACING @ 8' - 0" O.C.

\_

---

L.

TRAFFIC SIDE

_._j

2-~~,

\!

2-@#4\
- ,-------

0
~

en
w

0:::

~ ~
a::: en

....1

11..

FINISHED HMA ROADWAY GRADE


AT CURB LINE= PIVOT POINT
FOR BARRIER GEOMETRY

""' ""

'"'-'-'

:..;..>

;\

Ill

:5
en

I I

Jj

[\_ cu RB
7
'L_

@)

6-@#4

#fj

:5 ~

en

20 -

0:::

#4 W/
2' - 0" MIN.
SPL. (TYP.)

(j)

1" EXPANDED POLYSTYRENE

RUSTICATION -SEE RUSTICATION DETAIL


FOR STRUCTURAL DETAILS BELOW THE MATCH LINE,
SEE STANDARD PLANS D-3.09, D-3.10 OR D-3.11.
1/2" EXPANSION JOINT WITH PREMOLDED JOINT FILLER.
INSTALL BARRIER DUMMY JOINTS ON TRAFFIC SIDE ONLY
WHEN ARCHITECTURAL FEATURES ARE SPECIFIED.

SLAB BASE

BARRIER EXPANSION
JOINT SPACING
MIN.

MAX.

5'- 0"

80'- 0"

120'- 0"

8'- 0"

6'- 0"

60'- 0"

80'- 0"

9'- 0"

7'- 0"

40'- 0"

60'- 0"

ON WALL AT GRADE

MIN.

MAX.

80'- 1"

--

7'- 0"

60'- 1"

80'- 0"

40'- 1"

60'- 0"

40'- 0"

CONTACT BRIDGE OFFICE

#5 @ 8" O.C.
MATCH LINE(/)

@ #4 - 2" CLR. FROM TOP


(SEE STD. PLAN D-3.10 OR D-3.11)

#5 - @ 8 " O.C.

....1

MO

0, MATCH LINE

ELEVATION

THE NOTCH, DETAILED BY THESE DIMENSIONS AND


SPECIFICATIONS, IS REQUIRED ONLY IF THE BARRIER
IS ON WALL FACING.

SLAB LENGTH

0:::

Ill '

#4 @ 1'- 4" O.C.

W, (j)

CONSTRUCTION JOINT WITH ROUGHENED SURFACE.

LINE

~~

3" MIN. CLR.

1 1/2" MIN. CONCRETE COVER - INCREASE THE COVER


AS REQUIRED TO ACCOMMODATE ARCHITECTURAL
FEATURES AND FINISH.

2 LAYERS 15 LB.
TAR PAPER

11..

JUNCTION BOX (MOUNT BOX SO COVER IS FLUSH WITH


THE BARRIER FACE WITH A 0" TOLERANCE PROTRUDING
BEYOND THE BARRIER FACE AND 1/8" RECESSED).
USE NEMA 4X JUNCTION BOX WITH STATIONARY-FORMS
- SEE STANDARD PLAN J-40.36. USE NEMA 3R JUNCTION
BOX WITH SLIP-FORMS - SEE STANDARD PLAN J-40.37.

'

I-

THE BARRIER GEOMETRY REFERENCE LINE (B.G.R.L.)


IS PERPENDICULAR TO THE TRANSVERSE ROADWAY
SLOPE (T.R.S.). FOR SUPERELEVATED TRANSVERSE
ROADWAY SLOPES, THE B.G.R.L. ON THE LOW SIDE
OF THE ROADWAY SHALL BE PERPENDICULAR TO THE
T.R.S. UP TO A MAXIMUM OF 8% SUPERELEVATION;
THE B.G.R.L. ON THE HIGH SIDE SHALL ALWAYS BE
PERPENDICULAR TO THE T.R.S ..

{)u::: 0:3

- ..

____:1_

--

CD

2#fj CONTINUOUS
WITH 3' - 8" MIN. SPLICE
3/4" CHAMFER (TYP.)

,\

_ _ 'z.

SHOWN AT GRADE

#5@ 8" O.C.

TYPICAL SECTION

~ SEE EXPANSION JOIN T DETAIL ON


STANDARD PLAN D-3.1 7

\
7

MOMENT
SLAB

(REINFORCING STEEL NOT SHOWN)

PLAN VIEW

L.

MOMENT SLAB
CONST. JOINT

JOINT SCHEME
2" CLR

~
EXPANSION
JOINT (TYP.)

EXP. JOINT

ct.

TRANSVERSE ROADWAY
SLOPE

FINISHED
GRADE

7'

FINISHED HMA ROADWAY


GRADE AT CURB LINE =
PIVOT POINT FOR BARRIER
GEOMETRY

SINGLE SLOPE
BARRIER

SPACING@
8'- 0" O.C.

BARRIER EXPANSION JOINT SPACING (SEE TABLE)

BARRIER
DUMMY JOINT

4' - 0" MIN. TO 8' - 0" MAX. O.C.

BARRIER GEOMETRY
REFERENCE LINE

FILL MATERIAL SPECIFIED


ELSEWHERE IN CONTRACT

#4 (SEE STD. PLAN D-3.10 OR D-3.11)


FACE OF CAST-IN-PLACE FASCIA
GEOSYNTHETIC

NOTE

01'-0"

REINFORCING

STEEL

BENDING

DIAGRAM

ALL REINFORCING BARS SHOWN ON


THIS PLAN SHALL BE AASHTO M 31
UNLESS OTHERWISE NOTED.

:Z

ALL DIMENSIONS ARE OUT TO OUT

'

{(

N::::i

I~ ~

<(

:::!:

PERMANENT
GEOSYNTHETIC WALL
SINGLE SLOPE BARRIER
STANDARD PLAN D-3.15-02

:Z
'co

::c

SHOWN ON WALL

COI-

,u..

TYPICAL SECTION
-----.-

~~

(SEE TABLE)

f4

:il

"o/ = EPOXY COATED

1. All cast-in-place concrete


shall be class 4000.

11 1/4"

SLAB BASE - 4"

SLAB BASE (SEE TABLE)

<(

SHEET 1 OF 1 SHEET

:::!:

::c

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

(j)

......

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

#5

DUMMY JOINT DETAIL

RUSTICATION DETAIL

KEYNOTES
en

MOMENT SLAB CONSTRUCTION JOINT SPACING@ 120'- 0" MAX.

zw
w

BARRIER EXPANSION JOINT


(SEE TABLE)

Ill
....1
....1

iii

BARRIER EXPANSION JOINT SPACING (SEE TABLE)

BARRIER
DUMMY JOINT

BARRIER DUMMY JOINT SPACING


4' - 0" MIN. TO 8' - 0" MAX. O.C.

BARRIER DUMMY JOINT SPACING @ 8' - 0" O.C.

FINISHED HMA ROADWAY


GRADE AT CURB LINE=
PIVOT POINT FOR BARRIER
GEOMETRY (TYP.)

F-SHAPE
BARRIER

SPACING@
8'- 0" O.C.

BARRIER GEOMETRY
REFERENCE LINE

1
EXPANSION JOINT <t_

0::

TRANSVERSE ROADWAY
SLOPE

FINISHED
GRADE

TERMINUS

~
DUMMY JOINT (TYP.)
~ (SEE DETAIL)

TRAFFIC SIDE

EXPANSION
JOINT (TYP.)

JOINT SCHEME

(REINFORCING STEEL NOT SHOWN)

PLAN VIEW

TYPICAL SECTION

EXP. JOINT

<t

2-(j)'/\\

CD

2" CLR

a:0::

u:::

u.

I-

'7.

____::i
\

en
w

0::

()

a:0::

~
en

b
.....

<(
Ill

L'?' :

.....

.....

""

~
TOP OF ROADWAY

=>

u:::
u.

0
w

0::

""" ":-

""'-'-

,\

,;_c..-'

I-

=>

en

-@#41

@#6W,

(i)#5

MATCH LINE

ALL REINFORCING BARS SHOWN ON


THIS PLAN SHALL BE AASHTO M 31
UNLESS OTHERWISE NOTED.
ALL DIMENSIONS ARE OUT TO OUT

'o/ = EPOXY COATED

:Z
~

(SEE TABLE)

~I(

Iu.
::::i

ro :s
....1

@#5

!::!::

MIN.

MAX.

80'- 1"

--

7'- 0"

5'- 0"

80'- 0"

120'- 0"

60'- 1"

80'- 0"

8'- 0"

6'- 0"

60'- 0"

80'- 0"

40'- 1"

60'- 0"

9'- 0"

7'- 0"

40'- 0"

60'- 0"

40'- 0"

CONTACT BRIDGE OFFICE

(j)

@#6W

SHOWN ON WALL

PERMANENT
GEOSYNTHETIC WALL
F - SHAPE BARRIER
STANDARD PLAN D-3.16-02

:::!!::::!!:
:Z ::c=
0
~ + .....

= u.
.....
..... :so

....1

::c

~
@#4

<(

iY:l

:s
:::!!:

::c

10~

I-

<(
::::!!;

::c

ON WALL AT GRADE

MAX.

1. All cast-in-place concrete


shall be class 4000.

<(~

I-

<(

BARRIER EXPANSION
JOINT SPACING

NOTE

::J~

.....,.

r-.
@#5

u.

N !::!::

:::!!:

SLAB BASE

TYPICAL SECTION
I-

.....

INSTALL BARRIER DUMMY JOINTS ON TRAFFIC SIDE ONLY


WHEN ARCHITECTURAL FEATURES ARE SPECIFIED.

GEOSYNTHETIC

SLAB BASE (SEE MOMENT SLAB TABLE)

DIAGRAM

:Z

SLAB BASE - 4"

6 3/4"

1/2" EXPANSION JOINT WITH PREMOLDED JOINT FILLER.

FILL MATERIAL SPECIFIED


ELSEWHERE IN CONTRACT

FACE OF CAST-IN-PLACE FASCIA

BENDING

FOR STRUCTURAL DETAILS BELOW THE MATCH LINE,


SEE STANDARD PLANS D-3.09, D-3.10 OR D-3.11.

@ #5@ 8" O.C.

<5)1'-0"

STEEL

RUSTICATION -SEE RUSTICATION DETAIL

@ #4 (SEE STD. PLAN D-3.10 OR D-3-11)

@ 8" O.C.

ELEVATION
REINFORCING

a::

....1

i")()

@ #4 - 2" CLR. FROM TOP


(SEE STD. PLAN D-3.10 OR D-3.11)

@ #4@ 1'- 4" O.C.

6-@#4

0. MATCH LINE

~~

3" MIN. CLR.

6
20-@ #4W/
2' - 0" MIN.
SPL. (TYP.)

<5) 1" EXPANDED POLYSTYRENE

THE NOTCH, DETAILED BY THESE DIMENSIONS AND


SPECIFICATIONS, IS REQUIRED ONLY IF THE BARRIER
IS ON WALL FACING.

SLAB LENGTH

u.

~ ~

'7

CONSTRUCTION JOINT WITH ROUGHENED SURFACE.

2 LAYERS 15 LB.
TAR PAPER

MIN.

I\_ cu RB LINE

1 1/2" MIN. CONCRETE COVER - INCREASE THE COVER


AS REQUIRED TO ACCOMMODATE ARCHITECTURAL
FEATURES AND FINISH.

....1

1/

JUNCTION BOX (MOUNT BOX SO COVER IS FLUSH WITH


THE BARRIER FACE WITH A 0" TOLERANCE PROTRUDING
BEYOND THE BARRIER FACE AND 1/8" RECESSED).
USE NEMA 4X JUNCTION BOX WITH STATIONARY-FORMS
- SEE STANDARD PLAN J-40.36. USE NEMA 3R JUNCTION
BOX WITH SLIP-FORMS - SEE STANDARD PLAN J-40.37.

<(

()

I I

STANDARD PLAN D-3.17

,\

ii'i
()

~SEE EXPANSION JOINT DETAIL ON

7 1/4"

#6 CONTINUOUS
2WITH 3' - 8" MIN. SPLICE

@ #5@ 8" O.C.

<5)

SHOWN AT GRADE

0::

MOMENT
SLAB

3/4" CHAMFER (TYP.)

2-@#4l

MOMENT SLAB
CONST. JOINT

THE BARRIER GEOMETRY REFERENCE LINE (B.G.R.L.)


IS PERPENDICULAR TO THE TRANSVERSE ROADWAY
SLOPE (T.R.S.). FOR SUPERELEVATED TRANSVERSE
ROADWAY SLOPES, THE B.G.R.L. ON THE LOW SIDE
OF THE ROADWAY SHALL BE PERPENDICULAR TO THE
T.R.S. UP TO A MAXIMUM OF 8% SUPERELEVATION;
THE B.G.R.L. ON THE HIGH SIDE SHALL ALWAYS BE
PERPENDICULAR TO THE T.R.S ..

SHEET 1 OF 1 SHEET

q::::

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

(i)#5

DUMMY JOINT DETAIL

RUSTICATION DETAIL

CAST-IN-PLACE CONCRETE BARRIER

rn
z

PRECAST CONCRETE BARRIER

NOTE

0::

EXPANSION JOINT

w
m
....1
....1

iii

1. Ensure that no concrete enters the PVC


conduit during concrete placement.

9"

1/2" PREMOLDED JOINT FILLER


IN EXPANSION JOINT

t_ PVC CONDUIT

1 1/4" PVC CONDUIT (TYP.) TO BE INSTALLED


PARALLEL TO GRADE AND
PARALLEL TO FACE OF BARRIER

PVC CAP (TYP.)

CURB LINE
CONNECTION BLOCKOUT
IN PRECAST BARRIER
SEE STANDARD PLAN C-70.10
CURB LINE

SECTION

FOR DETAILS NOT SHOWN - SEE TYPICAL SECTION


STANDARD PLAN D-3.15 OR D-3.16

EXPANSION JOINT DETAIL


FOR CAST-IN-PLACE TO PRECAST
BARRIER CONNECTION

1/2" MIN. EXPANSION GAP


BETWEEN BAR AND CAP

EXPANSION JOINT
1/2" PREMOLDED JOINT FILLER
IN EXPANSION JOINT

1 1/4" PVC CONDUIT (TYP.) TO BE INSTALLED


PARALLEL TO GRADE AND
PARALLEL TO FACE OF BARRIER

t_

PVC CONDUIT

PVC CAP (TYP.)

CURB LINE

CURB LINE
1/2" MIN. EXPANSION GAP
BETWEEN BAR AND CAP

REINFORCING

STEEL

ALL REINFORCING BARS SHOWN ON


THIS PLAN SHALL BE AASHTO M 31
UNLESS OTHERWISE NOTED.

BENDING

DIAGRAM

ALL DIMENSIONS ARE OUT TO OUT

W =EPOXY COATED

L
EXPANSION JOINT DETAIL

SECTION

FOR DETAILS NOT SHOWN - SEE TYPICAL SECTION


STANDARD PLAN D-3.15 OR D-3.16

PERMANENT
GEOSYNTHETIC WALL
EXPANSION .JOINT DETAILS
STANDARD PLAN D-3.17-01
SHEET 1 OF 1 SHEET

@)
@
@

APPROVED FOR PUBLICATION

#4 L=7"
#4 L = 8 7/8"
#4 L = 10 3/4"

Pasco Bakotich Ill

.....

------~s=~=TE~D=Es=IG~N=EN=GI=NE=ER~----

05117112
DATE

~ Washington State Department of Transportation

NOTES
f

-1
\

ASPHALT CONCRETE
PAVEMENT-

1. SEE CONTRACT FOR BACKFILL LIMITS AND GEOTUCTILE CLASS.

CONSTRUCTION GEDTUCTllE
FOR UNDERGROUND DRAINAGE,
MODERATE SURVIVABILITY.

FOR WALLS

UNDERDRAIN PIPE

GRAVEL BACKFILL
FOR DRAINS.

CONDITION A OR CONDITION B
WlTH GEOTEXTILE

GRAVEL BACKFILL
m R DRAINS
UNDERDRAIN PlPE

1_1'-6"_1
MIN

CONDITION A

GRAVEL BACKFILL
FORWALLS

GRAVEL BACKFILL
FOR DRAINS

b
b

-, ,

..

. . ... ..
. .

b b

UNDERDRAIN PlPE
b . .

ALTERNATE DETAIL

BACKFILL AND DRAINAGE


FOR RETAINING WALLS
STANDARD PLAN D-4

TYPICAL FOR CONSTRUCTIONWlTH SHORING.

MIN

CONDITION B

NOTE' THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENTBUT AN ELECTRONIC DUPLICATE


THE ORIGINAk SIGNED BY THEENGINEER ANOAFFROLED FOR WBUCATION, IS KEPT ONFILE
ATTHE WASHINGTON STATE DEPARTMENTOF TRANSPORTATION. A COPY MAYBE OBTAINED
UPON REQUEST.

APPROVED FOR PUBLICATION

Clifford E. Mansfield
DEPUTY STATE DESIGN ENGINEER

10/9B
DATE

REMOVED GURADRAIL. CURB & METAL CRIB WALLS.


RMSION

MT

1241/98
DATE

WASHINGTON STATE DEPARTMENTOF TRANSPORTATION


OLYMPIA. WASHINGTON

Double loop

Single loop

LACING DETAIL

Six i ndependent
wires encompassed
Unit A
Unit B
Unit C

2 ce I I gob i on
3 ce I I gob i on
4 ce I I gob i on

FASTENING ADJACENT BASKETS

TYPICAL GABION
TWISTED FABRIC

Three verticol ond


two horizontal
wi res encompassed

WELDED FABRIC
CROSS CONNECTING WIRE
PLACMENT, INTERIOR CELLS
OF FRONT GABIONS

GAB IONS
STANDARD PLAN D-6

CROSS-CONNECTING WIRE
PLACEMENT, END CELLS

APPROVED FOR PUBLICATION

Clifford E. Mansfield

....

DEPUTY STATE DESIGN ENGINEER

~~

6119198
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

NOTES

en
z

w
w

a:

FRONT

1. All concrete shall be Class 4000, except as noted.

BACK

[I]

....1
....1

2. For backfill requirements, see Standard Plan


D-4.

SPLIT VIEW
LINE

FACE OF WALL

iii

48' WALL SECTION


(BETWEEN JOINTS)

250 PSF EQUIVALENT LIVE LOAD


SURCHARGE WHEN
SPECIFIED IN CONTRACT

48' WALL SECTION

(BETWEEN JOINTS)

Cl

24' MIN. VERTICAL CURVE AT


ALL ANGLE OR (BREAK) POINTS
IN TOP OF WALL PROFILE

J__

3"CLR.~

1 1/2" CLR. MIN.

3. When Wall Type 1SW (saltwater) is specified,


the concrete cover over steel in the front face
and the total wall thickness shall be increased
by 1".
4. When Wall Type 1SW (saltwater) is specified,
concrete in the table column "Material Quantity"
shall be increased by (0.003 x H) CY/LF.
5. Concrete in the 48 foot wall sections shall be
placed separately between expansion joints with
a minimum 24 hour period before placing concrete
in the adjacent section.

@#4

SURFACE TREATMENT

#4@ 1' -6"


CENTERS

1 1/2" CLR.

6. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.51 g.
7. If Traffic Barriers are required, See Standard Plans
D-15.10, D-15.20 and D-15.30.

EXPANSION JOINT - 48' CENTERS,


WI 1/2" PREMOLDED JOINT FILLER

(SEE NOTE 3)

VERTICAL FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

#4@ 1'- 6" MAX.(TYP.)

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL

WITH 2' - 0" LAP SPLICE


AND EXTENDING THRU
CONSTRUCTION JOINT
SEE BAR@TABLE

1---------B----------1

FRONT

I
I

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

I
BACK

TYPICAL SECTION

BAR@ #4
LOCATION

TOP
OF
FOOTING

BOTTOM
OF
FOOTING

WALL
HEIGHT
(H)

QTY.

!5.. 16'
16' !5..23'

5
7

23' !5..28'
29' !5..35'

9
11

!5.. 16'
16' !5..23'

5
7
9
11

23' !5..28'
29' !5..35'

SPLIT ELEVATION VIEW


OFFSET - SET TOP OF WALL BACK:
H~20' .......... OFFSET= 1/2"
H.::_ 20' .......... OFFSET (inches) = H (ft)

<2) WHEN THE CONTRACT SPECIFIES


CABLE FENCE, BACKFILL AND THE
CEMENT CONCRETE GUTTER SHALL
BE PLACED 6" MIN. FROM THE TOP
OF THE WALL

(SHOWING SEPARATE REBAR LAYERS)

-2

REINFORCED CONCRETE
RETAINING WALL
TYPE 1 AND 1SW
STANDARD PLAN D-10.10-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

6'- 6"
6'- 6"
6'- 6"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 3"
8'- 9"
9'- 3"
9'- 9"
10'- 3"
10'- 9"
11'- 6"

~
2'- 0"
2'- 0"
2'- 3"
2'- 3"
2'- 3"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 6"
2'- 6"
2'- 9"
3'- 0"
3'- 3"
3'- 6"
3'- 6"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

12'- 0"
12'- 6"
13'- 0"
13'- 9"
14'- 3"
14'- 9"
15'- 6"
16'- 0"
16'- 9"
17' - 3"
18'- 0"
18'- 6"
19'- 3"
20'- 0"
20'- 6"

3'- 9"
4'- 0"
4'- 3"
4'- 3"
4'- 6"
4'- 9"
5'- 0"
5'- 3"
5'- 6"
5'- 9"
6'- 0"
6'- 3"
6'- 6"
6'- 9"
7'- 0"

BAR@#4

BAR@

BAR

LENGTH

SIZE SPA.

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 6"
1'- 6"
1'- 9"
1'- 9"

1'- 4"
1'- 5 1/2"
1'- 6 1/2"
1'- 7 1/2"
1'- 9"
1'- 10"
1'-111/2"
2'- 0 1/2"
2'- 1 1/2"
2'- 3"
2'- 4"
2'- 5"
2'- 6"
2' -7"
2'- 8"
2'- 9 1/2"

3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3' -7"
3'- 10"
3'- 10"
4'- 1"
4'- 1"

2'2'2'2'2'2'2'2'2'2'2'3'3'3'3'3'-

9"
9"
9"
9"
9"
9"
9"
9"
9"
9"
9"
0"
3"
3"
6"
6"

2'- 0"
2'- 0"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 9"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 9"
4'- 0"
4'- 3"
4'- 6"

2'- 10"
2' - 11 1/2"
3'- 0 1/2"
3'- 1 1/2"
3'- 2 1/2"
3'- 3 1/2"
3'- 4 1/2"
3'- 5 1/2"
3'- 6 1/2"
3'- 7 1/2"
3'- 8 1/2"
3'- 9 1/2"
3'- 10"
3'- 11"
4'- 0"

4'- 4"
4'- 4"
4' -7"
4' -7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5' -7"
5' -7"
5'- 10"
6'- 1"
6'- 4"
6' -7"
6'- 10"

3'3'4'4'4'4'4'4'5'5'5'5'5'6'6'-

9"
9"
0"
0"
3"
3"
6"
9"
0"
0"
3"
6"
9"
0"
3"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#5

LENGTH

SIZE SPA.

BAR@

LENGTH

#6

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
9"
9"
8"
7"
8"
8"
8"
8"
8"
9"

6'
6'
6'
6'
6'
7'
7'
7'
7'
8'
8'
9'
9'
10'
10'
11'

3"
3"
3"
6"
9"
0"
3"
6"
9"
0"
6"
0"
6"
0"
6"
3"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
10"
10"
8"
8"
8"
8"
10"
10"
10"

6'
6'
6'
6'
6'
7'
7'
7'
7'
8'
8'
9'
9'
10'
10'
11'

3"
3"
3"
6"
9"
0"
3"
6"
9"
0"
6"
0"
6"
0"
6"
3"

#6
#6
#6
#6
#6
#6
#6
#6
#7
#7
#7
#7
#7
#7
#7

9"
8"
9"
7"
7"
6"
6"
6"
8"
7"
7"
7"
7"
7"
7"

11'
12'
12'
13'
14'
14'
15'
15'
16'
17'
17'
18'
19'
19'
20'

9"
3"
9"
6"
0"
6"
3"
9"
6"
0"
9"
3"
0"
9"
3"

#5
#5
#5
#5

10"
8"
8"
7"
10"
9"
9"
8"
8"
7"
7"
7"
7"
7"
7"

11'
12'
12'
13'
14'
14'
15'
15'
16'
17'
17'
18'
19'
19'
20'

9"
3"
9"
6"
0"
6"
3"
9"
6"
0"
9"
3"
0"
9"
3"

#6
#6
#6
#6
#6
#6
#6
#6
#6
#6
#6

STEM REINFORCEMENT

SIZE SPA.
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

LENGTH

BAR@

SIZE SPA.

#6
#6

1'- 6"
5' - 2"
4' - 7 1/2"
1'- 6"
6' - 2"
5' - 7 1/2"
1'- 6" 7' - 2 1/2" 6' - 7 1/2"
1'- 0" 8' - 2 1/2" 7' - 7 1/2"
1'- 0" 9' - 2 1/2" 8' - 7 1/2"
1'- 0" 10' - 2 1/2" 9' - 7 1/2"
10"
11'-21/2"
10' - 8"
10"
12' - 2 1/2"
11' - 8"
8"
13' - 2 1/2"
12' - 8"
7"
14' - 2 1/2"
13' - 8"
6"
15' - 3"
14' - 8"
6"
16' - 4"
15' - 8"
8"
17' - 4"
16' - 8"
6"
18' - 4"
17' - 8"
9"
19' - 5 1/2" 18' - 8 1/2"
7"
20' - 5 1/2" 19' - 8 1/2"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
10"
1'- 0"
1'- 0"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 0"
10"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
1'- 0"

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

12' - 10 1/2"
14' - 2 1/2"
15' - 6 1/2"
16' - 10"
18' - 1 1/2"
19' - 4 1/2"
18' - 7"
18' - 4"
19' - 111/2"
21' - 3 1/2"
22' - 7"
22' - 7 1/2"
22' - 4 1/2"
19' - 2 1/2"
21' - 1 1/2"

12' - 1"
13' - 5"
14' - 9"
16' - 0 1/2"
17' - 4"
18' - 7 1/2"
17' - 9 1/2"
17' - 6 1/2"
18' - 11"
20' - 3"
21' - 6 1/2"
21' - 7"
21' - 4"
17' - 111/2"
19' - 9"

BAR

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 4" 5' - 2 1/2"


4' - 4"
1'- 4" 5' - 2 1/2"
4' - 4"
1'- 4" 5' - 5 1/2"
4' - 7"
1'- 4" 5' - 5 1/2"
4' - 7"
1'- 4" 5' - 8 1/2"
4' - 10"
1'- 4" 5' - 8 1/2"
4' - 10"
1'- 0" 5' - 11 1/2"
5' - 1"
10"
6' - 2 1/2"
5' - 4"
1'- 4" 8' - 4 1/2" 7' - 2 1/2"
1'- 4" 8' - 4 1/2" 7' - 2 1/2"
1'- 4" 8' - 7 1/2" 7' - 5 1/2"
1'- 2" 8' - 10 1/2" 7' - 8 1/2"
1'- 0" 9' - 1 1/2" 7' - 11 1/2"
10"
10' - 8 1/2"
9' - 4"
1'- 0" 12' - 4"
10' - 10"

Q)

@#4

MATERIAL
QUANTITY

MAXIMUM SOIL PRESSURE (PSF)


EXTREME
EVENT I

EXTREME
EVENT2

1260
1350
1443
1631
1836
2060
2303
2455
2728
3022
3261
3403
3546
3658
3803
3970

1131
1311
1446
1660
1904
2178
2486
2676
3041
3451
3804
4031
4264
4422
4664
4926

1623
1850
2049
2217
2402
2604
2822
2958
3202
3462
3570
3628
3700
3741
3834
3905

4115
4227
4373
4544
4689
4802
4897
5043
5143
5257
5362
5509
5618
5729
5877

5173
5338
5592
5860
6120
6290
6454
6723
6898
7075
7258
7540
7733
7933
8224

4012
4083
4198
4311
4431
4515
4587
4713
4796
4888
4979
5111
5208
5308
5442

SERVICE STRENGTH

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

4'- 4"
5'- 4"
6'- 4"
7'- 4"
8'- 4"
9'- 4"
10'- 4"
11'- 4"
12'- 4"
13'- 4"
14'- 4"
15'- 1"
15'- 10"
16'- 10"
17'- 7"
18'- 7"

0.40
0.45
0.51
0.58
0.65
0.72
0.80
0.88
0.96
1.05
1.16
1.33
1.51
1.63
1.83
1.97

25.7
28.2
29.3
33.8
38.1
43.6
48.8
53.0
59.7
67.9
78.6
87.1
91.9
108.8
114.2
137.0

915
992
1046
1176
1318
1471
1636
1733
1915
2109
2277
2377
2478
2555
2658
2790

1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 0"
10"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
1'- 0"

19'- 6 1/2"
20'- 6 1/2"
21'- 3 1/2"
22'- 3 1/2"
23'- 0 1/2"
24'- 0 1/2"
24'- 9 1/2"
25'- 6 1/2"
26'- 4"
27'- 4"
28'- 1"
28'- 10"
29' -7"
30'- 4"
31'- 1"

19'- 4"
20'- 4"
21'- 1"
22'- 1"
22'- 10"
23'- 10"
24' -7"
25'- 4"
26'- 1"
27'- 1"
27'- 10"
28' -7"
29'- 4"
30'- 1"
30'- 10"

2.19
2.34
2.58
2.75
3.01
3.18
3.48
3.77
4.11
4.30
4.65
4.99
5.38
5.78
6.16

130.1
143.3
146.6
166.0
172.9
188.8
213.2
237.8
265.1
287.4
298.5
322.9
354.3
444.8
480.4

2892
2970
3074
3207
3310
3388
3467
3571
3653
3733
3817
3923
4009
4097
4203

SIZE SPA.

REINFORCEMENT NOTES

G)

VERTICAL FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

IF TRAFFIC BARRIER IS USED, ADD 0.100 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 1.
ADD 0.123 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

@ADD 28 LB/LF OF REINFORCING STEEL FOR BARRIER ALTERNATE 1 OR 19 LB/LF OF REINFORCING STEEL
FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

RADIUS
(SEE TABLE)

BAR

BAR@
en
z

w
c:::
w

[I]

....1
....1

1ii

@ 1' - 6" CENTERS

BAR

RADIUS

#4
#5
#6
#7
#8
#9
#10
#11

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#4
#5
#6
#7
#8
#9
#10

MIN. SPLICE
2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPE 1 AND 1SW
STANDARD PLAN D-10.10-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

Cl

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

NOTES

en
z

FRONT

w
w

BACK

1. All concrete shall be Class 4000, except as noted.

a:
FACE OF WALL

[I]

SPLIT VIEW
LINE

....1
....1

iii

48' WALL SECTION


(BETWEEN JOINTS)

250 PSF EQUIVALENT LIVE


LOAD SURCHARGE WHEN
SPECIFIED IN CONTRACT

.1.

2. For backfill requirements, see Standard Plan


D-4.

48' WALL SECTION


(BETWEEN JOINTS)

Cl

- - . - - - - - - - - - - - - r.l"i1<:~~~~~"7AVT"

24' MIN. VERTICAL CURVE AT


ALL ANGLE OR (BREAK) POINTS
IN TOP OF WALL PROFILE

-------1>

CEMENT CONC. GUTTER


(CL. 3000, 4" THICK)

4. When Wall Type 2SW (saltwater) is specified,


concrete in the table column "Material Quantity"
shall be increased by (0.003 x H) CY/LF.
5. Concrete in the 48 foot wall sections shall be
placed separately between expansion joints with
a minimum 24 hour period before placing concrete
in the adjacent section.

@#4

SURFACE TREATMENT

3. When Wall Type 2SW (saltwater) is specified,


the concrete cover over steel in the front face
and the total wall thickness shall be increased
by 1".

6. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.51 g.

#4@ 1' -6"


CENTERS

1 1/2" CLR.

7. If Traffic Barriers are required, see Standard Plans


D-15.10, D-15.20 and D-15.30.

EXPANSION JOINT - 48' CENTERS,


WI 1/2" PREMOLDED JOINT FILLER

SLOPING FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL
SEE BAR@TABLE

FRONT

WALL
HEIGHT
(H)

BACK

TYPICAL SECTION

BAR@ #4
LOCATION

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

QTY.

TOP
OF
FOOTING

< 12'
13' < 16'
17' < 22'
23' < 28'
29' < 35'

5
6
7
9
11

BOTTOM
OF
FOOTING

< 12'
13' < 16'
17' < 22'
23' < 28'
29' < 35'

5
6
7
9
11

OFFSET - SET TOP OF WALL BACK:


H~20' .......... OFFSET= 1/2"
H~20' .......... OFFSET (inches)= H(ft)

WHEN THE CONTRACT SPECIFIES


CABLE FENCE, BACKFILL AND THE
CEMENT CONCRETE GUTTER SHALL
BE PLACED 6" MIN. FROM THE TOP
OF THE WALL

SPLIT ELEVATION VIEW


(SHOWING SEPARATE REBAR LAYERS)

-2

REINFORCED CONCRETE
RETAINING WALL
TYPE 2 AND 2SW
STANDARD PLAN D-10.15-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

FOOTING REINFORCEMENT
WALL
HT
H

DIMENSIONS
B

Cv

BAR@#4

LENGTH

BAR@

BAR
SIZE SPA.

LENGTH

SIZE SPA.

LENGTH

STEM REINFORCEMENT
BAR@

BAR
SIZE SPA.

LENGTH

SIZE SPA.

BARQ)

LENGTH

SIZE SPA.

@#4

MATERIAL
QUANTITY

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

MAXIMUM SOIL PRESSURE (PSF)


SERVICE STRENGTH

EXTREME
EVENT I

EXTREME
EVENT2

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

6'- 9"
6'- 9"
7'- 0"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 3"
8'- 9"
9'- 6"
10'- 0"
10'- 6"
11'- 0"
11'- 6"
12'- 3"

3'3'3'3'3'3'3'3'3'3'3'4'4'4'5'5'-

0"
0"
3"
3"
6"
6"
6"
9"
9"
9"
9"
0"
3"
6"
0"
0"

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 9"
1'- 9"

1'- 4"
1' - 5 1/2"
1' - 6 1/2"
1' - 7 1/2"
1'- 9"
1'- 10"
1'-111/2"
2' - 0 1/2"
2' - 1 1/2"
2'- 3"
2'- 4"
2'- 5"
2'- 6"
2'- 7"
2'- 8"
2' - 9 1/2"

2'- 7"
2' - 7"
2' - 7"
2'- 7"
2' - 7"
2' - 7"
2' - 7"
2' - 7"
2' - 7"
2' - 7"
2'- 10"
2'- 10"
3'- 1"
3'- 1"
3'- 4"
3'- 4"

2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 0"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 9"
2'- 9"

#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#6
#6
#6
#6
#6

1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
9"
7"
9"
7"
5"
5"
6"
6"
5"
6"
5"

6'- 6"
6'- 6"
6'- 9"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 6"
9'- 3"
9'- 9"
10'- 3"
10'- 9"
11' - 3"
12'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"

6'- 6"
6'- 6"
6'- 9"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 6"
9'- 3"
9'- 9"
10'- 3"
10'- 9"
11' - 3"
12'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
10"
9"
8"
7"
7"
6"
5"
7"
6"
5"

5'- 2"
6'- 2"
7'- 2"
8'- 2"
9'- 2"
10'- 2"
11' - 2"
12'- 2"
13'- 2"
14'- 2"
15'- 2"
16' - 2"
17' - 2"
18'- 3"
19'- 3"
20'- 3"

4'- 7"
5' - 7"
6' - 7"
7'- 7"
8' - 7"
9' - 7"
10'- 7"
11'-7"
12' - 7"
13'- 7"
14' - 7"
15'- 7"
16' - 7"
17'- 7"
18'- 7"
19'- 7"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
10"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 10 1/2"
4'- 10 1/2"
5'- 10 1/2"
6'- 10 1/2"
7'- 10 1/2"
8'- 10 1/2"
9'- 10 1/2"
10'-11"
11'-11"
12'-11"
13'- 8"
14'- 8"
15'- 5"
16'- 5"
17'- 2"
18'- 2"

0.41
0.46
0.53
0.58
0.65
0.73
0.81
0.89
0.97
1.07
1.25
1.36
1.55
1.67
1.87
2.02

23.8
26.3
28.9
34.7
37.7
42.2
48.6
53.8
62.7
74.4
80.4
95.6
103.9
121.6
126.5
149.0

900
987
1076
1225
1325
1493
1677
1797
2004
2190
2359
2459
2572
2671
2701
2855

1244
1351
1476
1687
1833
2075
2341
2522
2826
3089
3313
3455
3615
3756
3800
4005

1163
1380
1548
1837
2043
2385
2780
3066
3563
3977
4280
4496
4733
4951
4989
5275

1620
1878
2006
2332
2486
2744
3027
3221
3545
3706
3766
3845
3951
4047
4051
4186

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

12'- 9"
13'- 3"
13'- 9"
14'- 3"
14' - 9"
15'- 6"
16'- 0"
16'- 6"
17'- 0"
17'- 6"
18'- 0"
18'- 9"
19'- 3"
19'- 9"
20'- 3"

5'5'6'6'6'6'7'7'7'8'8'8'8'9'9'-

6"
9"
0"
3"
6"
9"
0"
3"
6"
0"
3"
6"
9"
0"
3"

2'2'2'2'2'2'2'3'3'3'3'3'4'4'4'-

2'- 10"
2'-111/2"
3'- 0 1/2"
3' - 1 1/2"
3'- 2 1/2"
3'- 3 1/2"
3'- 4 1/2"
3'- 5 1/2"
3'- 6 1/2"
3'- 7 1/2"
3'- 8 1/2"
3'- 9 1/2"
3'- 10"
3' - 11"
4'- 0"

3' - 7"
3'- 7"
3'- 10"
3'- 10"
4'- 1"
4'- 1"
4'- 4"
4'- 7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5' - 7"
5'- 10"
6'- 1"

3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 6"
3'- 9"
4'- 0"
4'- 3"
4'- 3"
4'- 6"
4'- 9"
5'- 0"
5'- 3"
5'- 6"

#7
#7
#7
#7
#7
#8
#8
#8
#8
#8
#8
#8
#8
#8
#8

7"
6"
6"
6"
6"
7"
7"
7"
7"
6"
6"
6"
6"
6"
6"

12'- 6"
13'- 0"
13'- 6"
14'- 0"
14'- 6"
15'- 3"
15'- 9"
16'- 3"
16'- 9"
17' - 3"
17'- 9"
18'- 6"
19'- 0"
19'- 6"
20'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#5
#5

11"
10"
10"
8"
8"
7"
7"
7"
6"
9"
8"
8"
8"
7"
7"

12'- 6"
13'- 0"
13'- 6"
14'- 0"
14'- 6"
15'- 3"
15'- 9"
16'- 3"
16'- 9"
17' - 3"
17'- 9"
18'- 6"
19'- 0"
19'- 6"
20'- 0"

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
10"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
1'- 0"

10'- 4 1/2"
11' - 5"
12' - 6 1/2"
13'- 7"
14'- 8"
15'- 8 1/2"
16' - 9 1/2"
15'- 11"
16' - 0"
17'- 0 1/2"
18'- 1 1/2"
19'- 2 1/2"
19'- 2"
17'- 4 1/2"
18'- 9"

9' - 7"
10'- 7 1/2"
11'- 9"
12' - 9 1/2"
13'- 10 1/2"
14'-11"
16' - 0"
15'- 1 1/2"
15'- 0"
16' - 0"
17'- 1"
18'- 2"
18'- 1 1/2"
16' - 1 1/2"
17'- 4 1/2"

12"
12"
12"
12"
12"
12"
12"
12"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
10"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
1'- 0"

5'- 2"
5'- 2"
5'- 5"
5'- 5"
5'- 8"
5'- 8"
5' - 11"
6'- 2"
8'- 4"
8'- 4"
8'- 7"
8'- 10"
9'- 1"
10'- 8"
12'- 3 1/2"

4'- 4"
4'- 4"
4'- 7"
4'- 7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
7'- 2"
7'- 2"
7' - 5 1/2"
7'- 8"
7'- 11"
9' - 3 1/2"
10'- 9 1/2"

11"
11"
11"
11"
11"
11"
11"
11"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"

#6
#6
#6
#6
#6
#6
#6
#6
#8
#8
#8
#8
#8
#9
#10

1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
10"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
1'- 0"

19'- 4"
20'- 4"
21'- 1"
22'- 1"
22'- 10"
23'- 10"
24'- 7"
25'- 4"
26'- 1"
27' - 1"
27'- 10"
28' - 7"
29'- 4"
30'- 1"
30'- 10"

18'-111/2"
19'-111/2"
20'- 8 1/2"
21'- 8 1/2"
22'- 5 1/2"
23'- 5 1/2"
24'- 2 1/2"
24'- 11 1/2"
25'- 8 1/2"
26'- 9"
27'- 6"
28'- 3"
29'- 0"
29'- 9"
30'- 6"

2.25
2.39
2.64
2.79
3.06
3.24
3.53
3.83
4.14
4.33
4.65
5.03
5.38
5.74
6.12

141.1
157.4
164.2
175.1
180.6
198.4
214.5
243.9
267.4
290.5
303.1
330.6
361.5
454.5
487.8

2888
2987
3103
3202
3318
3391
3508
3626
3743
3765
3883
3978
4096
4214
4332

4052
4193
4356
4497
4660
4753
4916
5079
5243
5279
5444
5563
5727
5892
6057

5322
5540
5786
6004
6252
6346
6593
6842
7092
7128
7379
7509
7760
8012
8265

4207
4323
4462
4582
4725
4785
4933
5082
5232
5258
5411
5512
5667
5822
5978

0"
0"
3"
3"
6"
6"
9"
0"
3"
3"
6"
9"
0"
3"
6"

REINFORCEMENT NOTES

(D

IF TRAFFIC BARRIER IS USED, ADD 0.110 CY OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 1.
ADD 0.152 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

l
J

@ADD 16 LB/LF OF REINFORCING STEEL FOR BARRIER ALTERNATE 1 OR 23 LB/LF OF REINFORCING STEEL
FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

Jn~
h

10

11/2"R

~k
BAR@
en
z

w
c:::
w

[I]

....1
....1

1ii

@ 1' - 6" CENTERS

SLOPING FACE WALL DESIGN


WITH A 250 PSF SURCHARGE

RADIUS
(SEE TABLE)

~b~
BAR

RADIUS

#4
#5

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#6
#7
#8
#9
#10
#11

BAR
#4
#5

#6
#7
#8
#9
#10

MIN. SPLICE
2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPE 2 AND 2SW
STANDARD PLAN D-10.15-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

Cl

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

NOTES

en
z

w
w

a:

FRONT

[I]

....1
....1

3/4" CHAMFER
(TYP.)

BACK

1. All concrete shall be Class 4000, except as noted.

SPLIT VIEW
LINE

2. For backfill requirements, see Standard Plan


D-4.

FACE OF WALL

iii

BACK FACE
OF WALL

Cl

48' WALL SECTION

48' WALL SECTION

(BETWEEN JOINTS)

(BETWEEN JOINTS)

24' MIN. VERTICAL CURVE AT


ALL ANGLE OR (BREAK) POINTS
IN TOP OF WALL PROFILE

:)__

WALL TOP DETAIL


3"CLR.

r-=-

1 1/2" CLR. MIN.


SEE CEMENT GONG.
GUTTER DETAIL

#4@ 1'- 6"

4. When Wall Type 3SW (saltwater) is specified,


concrete in the table column "Material Quantity"
shall be increased by (0.003 x H) CY/LF.

5. Concrete in the 48 foot wall sections shall be


placed separately between expansion joints with
a minimum 24 hour period before placing concrete
~~-L~---t---tl___, J ONLY FOR Hz. 21
in the adjacent section.

TOP OF WALL

CENTERS (MAX.)
BOTH FACES

3. When Wall Type 3SW (saltwater) is specified,


the concrete cover over steel in the front face
and the total wall thickness shall be increased
by 1".

SURFACE TREATMENT

6. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.51 g.

@#4@ 1' -6"


CENTERS

1 1/2" CLR.
(SEE NOTE 3)

EXPANSION JOINT - 48' CENTERS,


W/1/2" PREMOLDED JOINT FILLER
DRAIN

CEMENT CONC.
GUTTER DETAIL

VERTICAL FACE WALL DESIGN


WITH 2:1 BACKSLOPE

#4@ 1'- 6" MAX.(TYP.)


WITH 2' - 0" LAP SPLICE
AND EXTENDING THRU
CONSTRUCTION JOINT

#4@ 1'- 6"


CENTERS (MAX.)
ONLY USED WHEN
H .2 13'

SEE BAR@TABLE

~--------------8--------------~

BAR@ #4
LOCATION

WALL
HEIGHT

9" MIN.
-~

t'

TYPICAL SECTION

QTY.

....

19' !5..24'
25' !5..30'

8
10

31' !5..35'

12

!5.. 11'

12' !5.. 18'


6
BOTTOM 1--..:..=....:=--:..::~1------''-----1
19' !5..24'
8
OF
FOOTING
10
25' !5..30'
12

OFFSET - SET TOP OF WALL BACK:


H.!:. 20' .......... OFFSET 1/2"
H ~ 20' .......... OFFSET (inches) = H (ft) _

[
2

~.

3"C~R. u~1'-0"
r-:-----=-

BOTTOM OF FOOTING
S

#4@ 1'- 6" SPACING

(TYP.)

FRONT FACE OF WALL


AT TOP OF FOOTING

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

I
BACK

(SHOWING SEPARATE REBAR LAYERS)

1 ~~
.
1 "-~.::.6

I
I

SPLIT ELEVATION VIEW


'~

hk

!5.. 11'
12' !5.. 18'

31' !5..35'

FRONT

.'

(H)

TOP
OF
FOOTING

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL

3"

REINFORCED CONCRETE
RETAINING WALL
TYPE 3 AND 3SW
STANDARD PLAN D-10.20-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

KEY DETAIL
REQUIRED ON WALLS WHERE H 2. 13'

Pasco Bakotich Ill

---------------------STATE DESIGN ENGINEER

......
fll

07-08-08
DATE

Washington State Department of Transportation

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

4'- 3"
4'- 3"
4'- 3"
4'- 6"
4'- 9"
5'- 6"
6'- 9"
8'- 3"
8'- 3"
8'- 3"
9'- 0"
9'- 3"
10'- 0"
10'- 9"
11'- 0"
11'- 9"

~
1'- 6"
1'- 6"
1'- 9"
1'- 9"
1'- 9"
2'- 0"
2'- 0"
3'- 0"
3'- 3"
3'- 6"
3'- 9"
4'- 0"
4'- 3"
4'- 3"
4'- 6"
4'- 6"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

13'- 0"
13'- 3"
13'- 9"
14'- 9"
15'- 0"
15'- 9"
16'- 9"
17'- 9"
18'- 3"
18'- 6"
19'- 0"
19'- 6"
20'- 3"
21'- 6"
23'- 0"

5'5'5'5'6'6'6'6'7'7'7'7'8'8'8'-

0"
3"
6"
9"
0"
3"
6"
9"
0"
3"
6"
9"
0"
3"
6"

BAR@#4

hk

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 9"
1'- 9"
2'- 0"
2'- 3"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 9"
1'- 9"
2'- 0"
2'- 3"

1'- 3"
1'- 4 1/2"
1'- 6"
1'-71/2"
1'- 9"
1'- 10 1/2"
2'- 0"
2' - 1 1/2"
2'- 3"
2'- 4"
2'- 5 1/2"
2'- 6 1/2"
2'- 7 1/2"
2'- 9"
2'- 10 1/2"
2'-111/2"

3'3'3'3'3'3'3'3'3'3'3'3'4'4'4'4'-

2'- 3"
2'- 6"
2'- 9"
2'- 9"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 9"
4'- 0"
4'- 0"
4'- 1"
4'- 3"
4'- 3"

2'2'2'2'3'3'3'3'3'3'4'4'4'4'4'-

3'- 1"
3'- 2"
3'- 3"
3'- 4 1/2"
3'- 6"
3'- 7 1/2"
3'- 8 1/2"
3'- 10"
4'- 0"
4'- 0 1/2"
4' - 1 1/2"
4'- 3"
4'- 4"
4'- 5 1/2"
4' -7"

4'- 6 1/2"
4'- 9 1/2"
5'- 0 1/2"
5'- 0 1/2"
5'- 3 1/2"
5'- 3 1/2"
5'- 6 1/2"
5'- 6 1/2"
5'- 9 1/2"
6'- 0 1/2"
6'- 3 1/2"
6'- 4 1/2"
6'- 6 1/2"
6'- 9 1/2"
6'- 10 1/2"

3"
6"
9"
9"
0"
0"
3"
3"
6"
9"
0"
0"
1"
3"
3"

LENGTH

3
3
3
3
3
3
3
3
3
6
6
9
0
0
3
6

1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"

h
2'2'2'2'2'2'2'2'2'3'3'3'3'3'3'4'-

BAR@

BAR
SIZE SPA.

9"
9"
9"
9"
9"
9"
9"
9"
9"
0"
0"
3"
6"
6"
9"
0"

4'- 0"
4'- 3"
4'- 6"
4'- 6"
4'- 9"
4'- 9"
5'- 0"
5'- 0"
5'- 3"
5'- 6"
5'- 9"
5'- 10"
6'- 0"
6'- 3"
6'- 4"

LENGTH

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
10"
9"

4'- 0"
4'- 0"
4'- 0"
4'- 3"
4'- 6"
5'- 3"
6'- 6"
8'- 0"
8'- 0"
8'- 0"
8'- 9"
9'- 0"
9'- 9"
10'- 6"
10'- 9"
11'- 6"

#4
#4
#4
#4
#4

7"
7"
7"
6"
6"
8"
6"
8"
8"
8"
8"
8"
8"
6"
7"

12'- 9"
13'- 0"
13'- 6"
14'- 6"
14'- 9"
15'- 6"
16'- 6"
17'- 6"
18'- 0"
18'- 3"
18'- 9"
19'- 3"
20'- 0"
21'- 3"
22'- 9"

#5
#5
#6
#6
#6
#6
#6
#6
#6
#7

SIZE SPA.

LENGTH

STEM REINFORCEMENT

BAR@
SIZE SPA.

BAR@

LENGTH

5'- 2"
6'- 2"
7'- 2"
8'- 2"
9'- 2"
10'- 2"
11'- 3 1/2"
12'- 3 1/2"
13'- 3 1/2"
14' - 3 1/2"
15'- 3 1/2"
16'- 5"
17'- 6 1/2"
18'- 7"
19'- 7"
20'- 8 1/2"

4'- 7 1/2"
5'- 7 1/2"
6'- 7 1/2"
7' - 7 1/2"
8'- 7 1/2"
9'- 7 1/2"
10'- 7 1/2"
11' -7 1/2"
12'- 7 1/2"
13'- 7 1/2"
14' - 7 1/2"
15'- 7 1/2"
16'- 8"
17'- 8"
18'- 8"
19'- 8"

8"
8"
8"
8"
8"
8"
9"
9"
9"
9"
9"
11"
1' - 1"
1' - 1"
1' - 1"
1'- 3"

#5
#5
#6
#6
#6
#6

4'- 0"
4'- 0"
4'- 0"
4'- 3"
4'- 6"
5'- 3"
6'- 6"
8'- 0"
8'- 0"
8'- 0"
8'- 9"
9'- 0"
9'- 9"
10'- 6"
10'- 9"
11'- 6"

#5
#5
#5
#5
#5
#6
#7
#7
#7
#8

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
10"
8"
7"
6"
7"
8"
7"
6"
7"

#6
#6
#6
#6
#7
#7
#7
#7
#8
#8
#8
#8
#8
#8
#8

7"
6"
6"
6"
7"
6"
6"
6"
7"
7"
7"
6"
6"
6"
6"

12'- 9"
13'- 0"
13'- 6"
14'- 6"
14'- 9"
15'- 6"
16'- 6"
17'- 6"
18'- 0"
18'- 3"
18'- 9"
19'- 3"
20'- 0"
21'- 3"
22'- 9"

#8
#9
#9
#10
#10
#10
#10
#10
#10
#10
#11
#11
#11
#11
#11

1'- 0" 13'- 4 1/2"


12'- 4"
1'- 3" #8
1'- 2"
14'- 10"
13'- 8 1/2" 1'- 6" #9
1'- 0"
14'-11"
13'- 9 1/2" 1'- 6" #9
1'- 0" 15'- 2 1/2" 13'-111/2" 1'- 8" #10
1'- 0" 16'- 7 1/2" 15'- 4 1/2" 1'- 8" #10
10"
16'- 1 1/2" 14'- 10 1/2" 1'- 8" #10
10"
17'- 7"
16'- 4"
1'- 8" #10
9"
17'- 10"
16'- 7"
1'- 8" #10
8"
17'- 10 1/2" 16'- 7 1/2" 1'- 8" #10
8"
19'- 3 1/2"
18'- 0 1/2" 1'- 8" #10
9"
20'- 10"
19'- 5"
1'- 10" #11
8"
20' -7"
19'- 2 1/2" 1'- 10" #11
7"
20'- 0"
18'- 7 1/2" 1'- 10" #11
7"
21'- 4"
19'-111/2" 1'- 10" #11
6"
20'- 2 1/2"
18'- 10"
1'- 10" #11

#4
#4
#4
#4
#4
#4

RADIUS
(SEE TABLE)

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 0"
1'- 2"
1'- 0"
1'- 0"
1'- 0"
10"
10"
9"
8"
8"
9"
8"
7"
7"
6"

7'- 5"
9'- 0"
9'- 3"
10'- 8"
10'- 11"
10'- 11"
11'- 2"
11'- 2"
11'- 5"
11'- 8"
13'- 5 1/2"
13'- 7"
13'- 9 1/2"
14'- 1"
14'- 3"

6'- 2"
7' - 6 1/2"
7' - 9 1/2"
9'- 0 1/2"
9'- 3 1/2"
9'- 3 1/2"
9'- 6 1/2"
9'- 6 1/2"
9'- 9 1/2"
10'- 0 1/2"
11'- 8"
11'- 10"
12'- 0"
12'- 4"
12'- 5 1/2"

1'- 3"
1'- 6"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 10"
1'- 10"
1'- 10"
1'- 10"
1'- 10"

#8
#9
#9
#10
#10
#10
#10
#10
#10
#10
#11
#11
#11
#11
#11

SIZE SPA.

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
9"
7"
7"
8"
6"
8"
8"
8"
7"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

BAR

Q)

MATERIAL
QUANTITY

@#4

MAXIMUM SOIL PRESSURE (PSF)


SERVICE STRENGTH

EXTREME
EVENT 1

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 10"
4'- 10"
5'- 10"
6'- 10"
7'- 10"
8'- 10"
9'- 10"
10'- 10"
11'-10"
12'- 7"
13'- 7"
14'- 4"
15'- 1"
16'- 1"
16'- 10"
17'- 7"

0.31
0.35
0.41
0.47
0.55
0.64
0.76
0.89
1.05
1.22
1.34
1.54
1.79
1.94
2.18
2.47

20.6
21.7
24.2
26.8
29.5
36.2
44.3
59.3
67.8
73.2
86.6
104.3
122.9
139.7
158.7
181.2

707
827
920
1020
1129
1238
1419
1493
1594
1672
1777
1869
2007
2186
2336
2561

928
1084
1198
1328
1525
1678
1923
1970
2088
2199
2347
2554
2756
3007
3225
3537

1019
1296
1557
2018
2647
2868
3126
2650
3050
3539
3783
4266
4560
5040
5583
6137

1'- 0"
1'- 2"
1'- 0"
1'- 0"
1'- 0"
10"
10"
9"
8"
8"
9"
8"
7"
7"
6"

18'- 8"
19'- 5"
20'- 2"
21'- 2"
21'- 11"
22'- 11"
23'- 8"
24'- 8 1/2"
25'- 5 1/2"
26'- 2 1/2"
26' -111/2"
27' - 11 1/2"
28'- 10 1/2"
29'- 8 1/2"
30'- 8 1/2"

18'- 7"
19'- 4"
20'- 1"
21'- 1"
21'- 10"
22'- 10"
23' -7"
24' -7"
25'- 4"
26'- 1"
26'- 10"
27'- 10"
28'- 9"
29' -7"
30' -7"

2.69
2.97
3.29
3.52
3.84
4.06
4.49
4.75
5.16
5.55
5.99
6.22
6.57
7.09
7.49

192.8
246.3
261.3
322.1
324.2
378.8
406.8
433.8
442.5
459.3
533.5
661.9
746.0
849.0
968.6

2583
2733
2881
2984
3136
3241
3382
3485
3633
3785
3934
4044
4162
4285
4381

3556
3774
3986
4122
4344
4489
4679
4816
5026
5249
5462
5620
5783
5941
6058

5870
6394
6813
6926
7476
7715
7870
7995
8403
8947
9370
9757
10009
10005
9904

SIZE SPA.

VERTICAL FACE WALL DESIGN


WITH 2:1 BACKSLOPE

f.1
lJ

----

~b~

BAR@
@ 1' - 6" CENTERS

en
z

w
w

0:::
[I]

....1
....1

1ii

I
Cl

BAR

RADIUS

#4

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#5
#6
#7
#8
#9
#10
#11

BAR

MIN. SPLICE

#4

2'- 0"
2'- 0"
2'- 0"
2'- 6"
3'- 3"
4'- 2"
5'- 3"

#5
#6
#7
#8
#9
#10

REINFORCED CONCRETE
RETAINING WALL
TYPE 3 AND 3SW
STANDARD PLAN D-10.20-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

07-08-08
DATE

Washington State Department of Transportation

NOTES

en
z

w
w

a:
[I]

FRONT

....1
....1

iii

1. All concrete shall be Class 4000, except as noted.

3/4" CHAMFER
(TYP.)

BACK

SPLIT VIEW
LINE

2. For backfill requirements, see Standard Plan


D-4.

FACE OF WALL

SPECIAL WALL TREATMENT


WHEN SPECIFIED
IN CONTRACT

9"

48' WALL SECTION


(BETWEEN JOINTS)

BACK FACE
OF WALL

Cl

WALL TOP DETAIL


b

3"CLR.~

48' WALL SECTION


(BETWEEN JOINTS)

24' MIN. VERTICAL CURVE AT


ALL ANGLE OR (BREAK) POINTS
IN TOP OF WALL PROFILE

LONG BAR EACH


SIDE OF JOINT

'

TOP OF WALL

@#4
1'- 6"

--:-J==r;===r==-=ft----1 J

SURFACE TREATMENT

ONLY FOR H ~ 21'

b
'

CENTERS

4. When Wall Type 4SW (saltwater) is specified,


concrete in the table column "Material Quantity"
shall be increased by (0.003 x H) CY/LF.
5. Concrete in the 48 foot wall sections shall be
placed separately between expansion joints with
a minimum 24 hour period before placing concrete
in the adjacent section.
6. This wall has been designed in accordance with
the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.51 g.

1 1/2" CLR.

@#4@ 1' -6"

3. When Wall Type 4SW (saltwater) is specified,


the concrete cover over steel in the front face
and the total wall thickness shall be increased
by 1".

CEMENT CONC.
GUTTER DETAIL

CONSTRUCTION JOINT WITH


ROUGHENED SURFACE

en

---+---

SLOPING FACE WALL DESIGN


WITH 2:1 BACKSLOPE

o zu
_
WI
_. :E ~

#4@ 1'- 6" MAX.(TYP.)

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL

WITH 2' - 0" LAP SPLICE


AND EXTENDING THRU
CONSTRUCTION JOINT

#4@ 1'- 6"


CENTERS (MAX.)
ONLY USED WHEN

H = 213;

SEE BAR@TABLE

FRONT

I
I

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

I
BACK
BAR@ #4

SEE KEY
DETAIL

1--------B------------1

SPLIT ELEVATION VIEW


9" MIN.

.,

TYPICAL SECTION

LOCATION

(SHOWING SEPARATE REBAR LAYERS)

:~

1~

OFFSET - SET TOP OF WALL BACK:


H~ 20' .......... OFFSET = 1/2"
H~ 20' .......... OFFSET (inches) = H (ft)

I
1 ~ ...
_j!'----=~===~~~J

-2

"C~R. ~~1'-0"
(TYP.)
r-:----=-

FRONT FACE OF WALL


AT TOP OF FOOTING

WALL
HEIGHT
(H)

BOTTOM OF FOOTING
S

#4@ 1'- 6" SPACING

TOP
OF
FOOTING

3"

12'
16'
22'
26'
30'

11'
~ 15'
~21'
~25'
~29'
~35'

KEY DETAIL
REQUIRED ON WALLS WHERE H ~ 13'

BOTIOM
OF
FOOTING

11'
12' ~ 15'
16' ~21'
22' ~25'
26' ~29'
30' < 35'

QTY.

4
6
8
10
12
14
4
6
8
10
12
14

REINFORCED CONCRETE
RETAINING WALL
TYPE 4 AND 4SW
STANDARD PLAN D-10.25-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

07-08-08
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

Washington State

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H

BAR@#4

BAR@

BAR

hk

LENGTH

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

4'- 3"
4'- 3"
4'- 3"
4'- 6"
5'- 0"
5'- 6"
6'- 0"
6'- 9"
7'- 0"
7'- 9"
8'- 3"
9'- 0"
9'- 9"
10'- 6"
11'- 0"
11'- 9"

~
2'- 9"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 9"
4'- 0"
4'- 6"
4'- 9"
5'- 0"
5'- 3"
5'- 6"
5'- 6"
6'- 3"
6'- 6"

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 6"
1'- 9"
1'- 9"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 6"
1'- 9"
1'- 9"

1'- 3"
1' -41/2"
1'- 6"
1'-71/2"
1'- 9"
1'- 10 1/2"
2'- 0"
2' - 1 1/2"
2'- 3"
2'- 4"
2'- 5 1/2"
2'- 6 1/2"
2'- 8"
2'- 9 1/2"
2'- 10 1/2"
3'- 0"

3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3' -7"
3' -7"
3'- 10"
3'- 10"
3'- 10"
4'- 1"
4'- 1"

2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 3"
3'- 6"
3'- 6"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
11"
9"
6"
8"
8"
8"

4'- 0"
4'- 0"
4'- 0"
4'- 3"
4'- 9"
5'- 3"
5'- 9"
6'- 6"
6'- 9"
7'- 6"
8'- 0"
8'- 9"
9'- 6"
10'- 3"
10'- 9"
11'- 6"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
11"
9"
7"
6"
6"
6"
8"

4'- 0"
4'- 0"
4'- 0"
4'- 3"
4'- 9"
5'- 3"
5'- 9"
6'- 6"
6'- 9"
7'- 6"
8'- 0"
8'- 9"
9'- 6"
10'- 3"
10'- 9"
11'- 6"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

12'- 6" 6'- 6"


13'- 6" 6'- 6"
13'- 9" 7'- 0"
14'- 6" 7'- 3"
15'- 0" 7'- 9"
15'- 9" 7'- 9"
16'- 3" 8'- 3"
16'- 9" 8'- 9"
17'- 6" 9'- 0"
18'- 0" 9'- 3"
18'- 9" 9'- 6"
19'- 6" 9'- 9"
20'- 0" 10'- 0"
20'- 9" 10'- 3"
21'- 3" 10'- 6"

2'- 0"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 6"
2'- 9"
3'- 0"
3'- 3"
3'- 6"
4'- 0"
3'- 9"
4'- 0"
4'- 1"
4'- 2"

2'2'2'2'2'2'2'3'3'3'4'3'4'4'4'-

3' - 1 1/2"
3'- 2 1/2"
3'- 4"
3'- 5"
3'- 6 1/2"
3'- 8"
3'- 9"
3'- 10 1/2"
3' - 11 1/2"
4'- 0 1/2"
4' - 1 1/2"
4'- 3"
4'- 4 1/2"
4'- 5 1/2"
4' -7"

4'- 4"
4' -7"
4' -7"
4'- 10"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5' -7"
5'- 10"
6'- 4"
6'- 1"
6'- 4"
6'- 6"
6'- 8"

3'- 9"
4'- 0"
4'- 0"
4'- 3"
4'- 3"
4'- 3"
4'- 6"
4'- 9"
5'- 0"
5'- 3"
5'- 9"
5'- 6"
5'- 9"
5'- 11"
6'- 1"

#5
#5
#5

7"
6"
6"
7"
7"
6"
6"
6"
6"
6"
6"
7"
7"
6"
6"

12'- 3"
13'- 3"
13'- 6"
14'- 3"
14'- 9"
15'- 6"
16'- 0"
16'- 6"
17' - 3"
17'- 9"
18'- 6"
19'- 3"
19'- 9"
20'- 6"
21'- 0"

#5
#5
#5
#5
#5
#5

8"
8"
8"
8"
6"
6"
8"
7"
7"
7"
7"
6"
6"
6"
7"

12'- 3"
13'- 3"
13'- 6"
14'- 3"
14'- 9"
15'- 6"
16'- 0"
16'- 6"
17' - 3"
17'- 9"
18'- 6"
19'- 3"
19'- 9"
20'- 6"
21'- 0"

0"
3"
3"
6"
6"
6"
9"
0"
3"
6"
0"
9"
0"
1"
2"

SIZE SPA.

#6
#6
#6
#6
#6
#6
#6
#6
#7
#7
#7
#7

LENGTH

SIZE SPA.

#6
#6
#6
#6
#6
#6
#6
#6
#7

Jn~
h

~k
BAR@
@ 1' - 6" CENTERS

w
0::
w

Ill
....1
....1

iii

BAR@

BAR@

LENGTH

#6
#7
#7
#7

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
11"
8"
7"
8"
7"
6"
7"
8"
7"
6"

5' - 1 1/2"
6' - 1 1/2"
7' - 1 1/2"
8' - 1 1/2"
9' - 1 1/2"
10'- 1 1/2"
11'-11/2"
12'- 1 1/2"
13'- 1 1/2"
14'- 3"
15'- 3"
16'- 3"
17' - 4"
18'- 6"
19'- 6"
20'- 6"

4' -7"
5' -7"
6' -7"
7'- 7"
8' -7"
9' -7"
10'- 7"
11'- 7"
12'- 7"
13'- 7"
14'- 7"
15'- 7"
16'- 7"
17'- 7"
18'- 7"
19'- 7"

8"
8"
8"
8"
8"
8"
8"
8"
8"
9"
9"
9"
11"
1' - 1"
1' - 1"
1' - 1"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

#8
#9
#9
#9
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10

1' -2"
1' -0"
1' -2"
1' -0"
1' -2"
1' -0"
10"
10"
9"
9"
8"
7"
7"
6"
6"

14'- 2"
13'- 1 1/2"
14' - 5 1/2"
13'- 4"
15'- 10"
14'- 8 1/2"
15'- 10 1/2"
14'- 9"
17'- 7 1/2" 16'- 4 1/2"
17'- 7"
16'- 4"
17'- 0 1/2" 15'- 9 1/2"
18'- 5 1/2" 17'- 2 1/2"
18'- 8 1/2" 17'- 5 1/2"
20' - 1 1/2" 18'- 10 1/2"
20' - 1 1/2" 18'- 10 1/2"
19'- 10 1/2" 18'- 7 1/2"
21'- 3 1/2" 20'- 0 1/2"
19'- 10 1/2" 18'- 7 1/2"
20'- 8"
19'- 5"

1'- 3"
1'- 6"
1'- 6"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#8
#9
#9
#9
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10

SIZE SPA.
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

BAR

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 2"
1'- 0"
1'- 2"
1'- 0"
1'- 2"
1'- 0"
10"
10"
9"
9"
8"
7"
7"
6"
6"

7'- 0"
8' -7"
8' -7"
8'- 10"
10'- 2 1/2"
10'- 2 1/2"
10'- 5 1/2"
10'- 8 1/2"
10'- 11 1/2"
11'- 2 1/2"
11'- 8 1/2"
11'- 5 1/2"
11'- 8 1/2"
11'- 2 1/2"
10'- 10"

5'- 11"
7'- 3"
7'- 3"
7'- 6"
8'- 9"
8'- 9"
9'- 0"
9'- 3"
9'- 6"
9'- 9"
10'- 3"
10'- 0"
10'- 3"
9'- 9"
9'- 5"

1'- 3"
1'- 6"
1'- 6"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#8
#9
#9
#9
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10
#10

SIZE SPA.

Q)

MATERIAL MAXIMUM SOIL PRESSURE (PSF)


QUANTITY

@#4

SERVICE STRENGTH

EXTREME
EVENT I

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 10"
4'- 10"
5'- 10"
6'- 10 1/2"
7'- 10 1/2"
8'- 10 1/2"
9'- 10 1/2"
10'- 10 1/2"
11'-101/2"
12'- 7 1/2"
13'- 7 1/2"
14'- 8"
15'- 8"
16'- 5"
17' - 2"
18'- 2"

0.31
0.35
0.41
0.47
0.56
0.64
0.73
0.84
1.00
1.19
1.31
1.53
1.67
1.81
2.06
2.22

20.6
23.0
25.5
28.2
31.1
36.2
40.0
51.0
57.5
66.8
77.7
92.5
113.0
132.6
146.5
170.2

552
666
771
862
969
1067
1184
1301
1388
1539
1657
1809
1927
2121
2126
2245

718
864
998
1112
1281
1440
1605
1767
1896
2104
2271
2480
2642
2909
2921
3085

856
1030
1335
1612
2056
2383
2732
2989
3229
3537
3915
4220
4489
5006
4937
5207

1'- 2"
1'- 0"
1'- 2"
1'- 0"
1'- 2"
1'- 0"
10"
10"
9"
9"
8"
7"
7"
6"
6"

18'- 10"
19'- 7"
20' -7"
21'- 4"
22'- 4"
23'- 4"
24'- 1"
24'- 10"
25' -7"
26'- 4"
26'- 10"
28'- 1"
28'- 10"
29'- 9"
30'- 8"

18'- 11"
19'- 8"
20'- 8"
21'- 5"
22'- 5"
23'- 5 1/2"
24'- 2 1/2"
24'- 11 1/2"
25'- 8 1/2"
26'- 5 1/2"
26'- 11 1/2"
28'- 2 1/2"
28'- 11 1/2"
29' -10 1/2"
30'- 9 1/2"

2.51
2.85
2.99
3.33
3.51
3.71
4.07
4.45
4.87
5.28
5.96
6.00
6.46
6.81
7.13

185.2
227.4
237.4
275.9
316.5
364.9
418.8
441.3
485.7
505.6
559.9
643.8
668.3
831.8
969.0

2472
2698
2746
2899
2944
3141
3219
3298
3451
3606
3793
3879
4034
4324
4611

3396
3703
3778
3989
4056
4328
4439
4552
4763
4982
5241
5357
5577
5833
6094

5756
6200
6450
6759
6897
7416
7593
7773
8081
8510
8856
9087
9518
9880
10364

SIZE SPA.

VERTICAL FACE WALL DESIGN


WITH 2:1 BACKSLOPE

l
J

10

11/2"R

en

LENGTH

STEM REINFORCEMENT

RADIUS
(SEE TABLE)

~b~
BAR

RADIUS

#4
#5

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#6
#7
#8
#9
#10
#11

BAR
#4
#5

#6
#7
#8
#9
#10

MIN. SPLICE

2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPE 4 AND 4SW
STANDARD PLAN D-10.25-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

07-08-08
DATE

Washington State Department of Transportation

en
z

FRONT

w
w

a:
FACE OF

[I]

WALL~

....1
....1

I
I

iii

BACK

3/4" CHAMFER
(TYP.)

"I"

9"

SPECIAL WALL TREATMENT


WHEN SPECIFIED
IN CONTRACT

Cl

1. All concrete shall be Class 4000, except as noted.

(BETWEEN JOINTS)

2. For backfill requirements, see Standard Plan


D-4.

OF WALL

LONG BAR EACH


SIDE OF JOINT

3. Concrete in the 48 foot wall sections shall be


placed separately between expansion joints with
a minimum 24 hour period before placing concrete
1 1/2" CLR. MIN.
in the adjacent section.

WALL TOP DETAIL


SEE CEMENT CONC.
GUTTER DETAIL
#4@ 1'- 6"
CENTERS (MAX.)
BOTH FACES

NOTES

SPLIT VIEW
LINE
48' WALL SECTION

4. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.20 g.

TOP OF WALL

SURFACE TREATMENT

@#4@1'-6"
CENTERS

---.--._

EXPANSION JOINT- 48' CENTERS,


W/1/2" PREMOLDED JOINT FILLER
3" DIAM. DRAINS AT ABOUT 12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT FRONT FACE OF WALL

CEMENT CONC.
GUTTER DETAIL

BAR@ #4
LOCATION

L
b

_.

CONSTRUCTION JOINT WITH


ROUGHENED SURFACE

"(.)
z_
WI
~

c[

---+--N
en

WALL
HEIGHT
(H)

QTY.

TOP
OF
FOOTING

.s. 13'
12' < 17'
18' < 22'
23' < 29'
30' .s.35'

4
5
7
9
13

BOTTOM
OF
FOOTING

.s. 13'
12' < 17'
18' < 22'
23' .S.29'
30' < 35'

4
5
7
9
13

VERTICAL FACE WALL DESIGN


WITH 2:1 BACKSLOPE

I
I

#4@ 1'- 6" MAX.(TYP.)


WITH 2' - 0" LAP SPLICE
AND EXTENDING THRU
CONSTRUCTION JOINT
SEE BAR@TABLE

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

#4@ 1'- 6"


CENTERS (MAX.)
ONLY USED WHEN
Hz26'

I
FRONT

BACK

9" MIN.
f---------- B

SPLIT ELEVATION VIEW

--------~

(SHOWING SEPARATE REBAR LAYERS)

TYPICAL SECTION

OFFSET - SET TOP OF WALL BACK:


H.s. 20' .......... OFFSET = 1/2"
Hz 20' .......... OFFSET (inches) = H (ft)

REINFORCED CONCRETE
RETAINING WALL
TYPES
STANDARD PLAN D-10.30-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

-2

Pasco Bakotich Ill


-~--~s=~=rE=oE=SIG=N=EN=GIN=EE=R---

KEY DETAIL
REQUIRED ON WALLS WHERE H > 26'

07-08-08
DATE

" ' Washington State Department of Transportation

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

4'- 3"
4'- 3"
4'- 3"
4'- 3"
4'- 3"
4'- 9"
5'- 6"
6'- 3"
6'- 6"
7'- 3"
7'- 9"
8'- 3"
8'- 9"
9'- 6"
10'- 0"
10'- 6"

~
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 9"
1'- 9"
2'- 0"
2'- 3"
2'- 3"
2'- 3"
2'- 6"
3'- 0"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

11'- 6"
12'- 3"
12'- 9"
13'- 6"
14'- 3"
14'- 6"
14'- 9"
15'- 3"
16'- 0"
17'- 0"
17'- 6"
18'- 3"
19"- 0"
20'- 0"
20'- 6"

3'3'3'4'4'4'4'5'5'6'6'6'7'7'7'-

6"
9"
9"
0"
6"
6"
9"
0"
6"
0"
3"
6"
0"
3"
6"

BAR@#4

hk

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 9"
2'- 0"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1' - 1 1/2"
1'- 3"
1'- 4"
1'- 5"
1'-61/2"
1' - 7 1/2"
1'- 9"
1'- 10"
1' - 11"
2'- 0 1/2"
2' - 1 1/2"
2'- 2 1/2"
2'- 3 1/2"
2'- 4 1/2"
2'- 5 1/2"
2'- 6 1/2"

3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 3
3'- 6
3'- 6
3'- 9
3'- 9
4'- 0
4'- 3

1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"

2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 9"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

2'2'2'2'2'2'2'3'3'3'3'3'4'4'4'-

N/A
N/A
N/A
N/A
N/A

2'- 7 1/2"
2'- 9"
2'- 10"
2'- 11"
3'- 0"
3'- 1"
3'- 2"
3'- 3"
3'- 4"
3'- 5"
3'- 6"
3' -7"
3'- 7 1/2"
3'- 9"
3'- 10"

4'- 3
4'- 3
4'- 6
4'- 6
4'- 9
5'- 0
5'- 0
5'- 3
5'- 6
5'- 6
5'- 9
6'- 0
6'- 3
6'- 3
6'- 6

1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"

3'- 9"
3'- 9"
4'- 0"
4'- 0"
4'- 3"
4'- 6"
4'- 6"
4'- 9"
5'- 0"
5'- 0"
5'- 3"
5'- 6"
5'- 9"
5'- 9"
6'- 0"

#5
#5
#5
#5
#5
#5
#5
#5
#5

0"
0"
3"
3"
6"
9"
9"
0"
3"
3"
6"
9"
0"
0"
3"

2'2'2'2'2'2'2'2'2'2'-

0"
0"
0"
0"
0"
0"
0"
0"
0"
0"

LENGTH

BAR@

BAR
SIZE SPA.

#5
#5
#5

#6
#6
#6
#6
#6
#6

LENGTH

SIZE SPA.

LENGTH

BAR@
SIZE SPA.

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
8"
8"
8"
8"
9"
9"
9"

4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 6"
5'- 3"
6'- 0"
6'- 3"
7'- 0"
7'- 6"
8'- 0"
8'- 6"
9'- 3"
9'- 9"
10'- 3"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"

4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 6"
5'- 3"
6'- 0"
6'- 3"
7'- 0"
7'- 6"
8'- 0"
8'- 6"
9'- 3"
9'- 9"
10'- 3"

#6
#6
#6

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
10"
8"
6"
8"
7"
6"
7"
6"
6"

9"
7"
7"
6"
6"
6"
6"
6"
6"
7"
7"
7"
7"
6"
6"

11'- 3"
12'- 0"
12'- 6"
13'- 3"
14'- 0"
14'- 3"
14'- 6"
15'- 0"
15'- 9"
16'- 9"
17' - 3"
18'- 0"
18'- 9"
19'- 9"
20'- 3"

#4
#4
#4
#4
#4
#4
#4
#4

10"
9"
9"
8"
7"
7"
6"
6"
8"
7"
7"
7"
8"
7"
7"

11'- 3"
12'- 0"
12'- 6"
13'- 3"
14'- 0"
14'- 3"
14'- 6"
15'- 0"
15'- 9"
16'- 9"
17' - 3"
18'- 0"
18'- 9"
19'- 9"
20'- 3"

#6
#6
#6
#8
#8
#8
#8
#8
#8
#9
#10
#10
#10
#10
#10

1'- 4"
1'- 4"
1'- 2"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"
9"

#5
#5
#5
#5

#6
#6
#6

STEM REINFORCEMENT

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

#5
#5
#5

BAR@

LENGTH

5'- 2"
6'- 2"
7'- 2"
8'- 2"
9'- 2"
10'- 2"
11'- 2"
12'- 2"
13'- 2 1/2"
14' - 2 1/2"
15'- 3 1/2"
16'- 3 1/2"
17'- 3 1/2"
18'- 5"
19'- 5 1/2"
20'- 5 1/2"

4' -7"
5' -7"
6' -7"
7'- 7"
8'- 7 1/2"
9'- 7 1/2"
10'- 7 1/2"
11' -7 1/2"
12'- 7 1/2"
13'- 7 1/2"
14'- 8"
15'- 8"
16'- 8"
17'- 8"
18'- 8"
19'- 8"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
9"
9"
9"
11"
11"
11"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

14'- 4"
15'- 7 1/2"
16'- 1"
15'- 3 1/2"
16'- 8"
18'- 0 1/2"
18'- 2 1/2"
18'- 1"
17'- 6 1/2"
16'- 9 1/2"
18'- 9"
17'- 7"
19'- 1"
18'- 11"
20'- 5"

13'- 5 1/2"
14'- 10"
15'- 3 1/2"
14'- 3"
15'- 7 1/2"
17'- 0"
17'- 2"
17'- 0 1/2"
16'- 6"
15'- 8"
17'- 6"
16'- 4"
17'- 10"
17'- 8"
19'- 2"

11"
11"
11"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#6
#6
#6
#8
#8
#8
#8
#8
#8
#9
#10
#10
#10
#10
#10

RADIUS
(SEE TABLE)

BAR

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 4"
1'- 4"
1'- 2"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"
9"

5'- 2 1/2"
5'- 2 1/2"
5'- 5 1/2"
7'- 4 1/2"
7'- 7 1/2"
7' -10 1/2"
7' -10 1/2"
8'- 1 1/2"
8'- 4 1/2"
9'- 8"
11'- 4"
11'- 7"
11'- 10"
11'- 10"
12'- 1"

4'- 4 1/2"
4'- 4 1/2"
4'- 7 1/2"
6'- 3 1/2"
6'- 6 1/2"
6'- 9 1/2"
6'- 9 1/2"
7' - 0 1/2"
7' - 3 1/2"
8'- 5"
9' -10 1/2"
10'- 1 1/2"
10'- 4 1/2"
10'- 4 1/2"
10'- 7 1/2"

11"
11"
11"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#6
#6
#6
#8
#8
#8
#8
#8
#8
#9
#10
#10
#10
#10
#10

SIZE SPA.

Q)

MATERIAL MAXIMUM SOIL PRESSURE (PSF)


QUANTITY

@#4

SERVICE STRENGTH

EXTREME
EVENT I

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 10"
4'- 10"
5'- 10"
6'- 10"
7'- 10"
8'- 10"
9'- 10"
10'- 10"
11'-10"
12'- 10"
13'- 7"
14'- 7"
15'- 4"
16'- 4"
17'- 1"
17'- 10"

0.30
0.34
0.39
0.44
0.50
0.58
0.67
0.76
0.84
0.94
1.09
1.19
1.36
1.49
1.68
1.88

19.3
21.7
22.8
25.3
27.7
32.0
37.6
43.9
49.6
61.9
69.5
79.2
89.0
108.6
122.5
128.5

706
825
930
1018
1211
1421
1623
1826
1963
2169
2306
2423
2677
2883
3021
3048

928
1084
1218
1362
1649
1946
2225
2508
2715
3001
3198
3369
3729
4015
4213
4256

831
982
1169
1401
1696
2000
2283
2570
2769
3060
3247
3405
3777
4068
4256
4268

1'- 4"
1'- 4"
1'- 2"
1'- 4"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"
9"

18'- 11"
19'- 11"
20'- 8"
21'- 8"
22'- 5"
23'- 2"
24'- 2"
24'- 11 1/2"
25'- 8 1/2"
26'- 8 1/2"
27'- 5 1/2"
28'- 2 1/2"
28'- 11 1/2"
29'- 11 1/2"
30'- 8 1/2"

18'- 10"
19'- 10"
20' -7"
21'- 7"
22'- 4"
23'- 1"
24'- 1"
24'- 10"
25' -7"
26' -7"
27'- 4"
28'- 1"
28'- 10"
29'- 10"
30' -7"

2.05
2.20
2.44
2.61
2.88
3.35
3.49
3.77
4.09
4.34
4.66
5.02
5.40
5.69
6.05

116.0
128.0
141.1
185.1
197.5
205.6
227.9
251.8
288.7
361.2
396.1
450.1
475.6
538.0
558.4

3015
3114
3355
3454
3481
3818
3955
4097
4117
4102
4245
4372
4411
4499
4640

4199
4337
4679
4816
4850
5330
5538
5739
5761
5729
5931
6103
6151
6267
6468

4180
4307
4655
4780
4792
5279
5474
5667
5667
5614
5808
5974
6006
6117
6310

SIZE SPA.

VERTICAL FACE WALL DESIGN


WITH 2:1 BACKSLOPE

f.1
lJ

----

~b~

BAR@
@ 1' - 6" CENTERS

BAR

RADIUS

#4

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

en

#5

0::

#6
#7
#8
#9
#10
#11

zw

CD

....1
....1

1ii

Cl

BAR
#4

#5

#6
#7
#8
#9
#10

MIN. SPLICE

2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPES
STANDARD PLAN D-10.30-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

07-08-08
DATE

Washington State Department of Transportation

en
z

FRONT

w
w

a:
FACE OF WALL

[I]

NOTES

SPLIT VIEW
LINE

BACK

1. All concrete shall be Class 4000, except as noted.

48' WALL SECTION

....1
....1

iii

3/4" CHAMFER
(TYP.)

2. For backfill requirements, see Standard Plan


D-4.

(BETWEEN JOINTS)

LONG BAR EACH


SIDE OF JOINT

BACK FACE
OF WALL

Cl

3. Concrete in the 48 foot wall sections shall be


placed separately between expansion joints with
a minimum 24 hour period before placing concrete
in the adjacent section.

1 1/2" CLR. MIN.

4. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.20 g.

WALL TOP DETAIL

SURFACE TREATMENT
TOP OF WALL

1'- 6"

@#4@ 1' -6"


CENTERS

H
b

'

EXPANSION JOINT - 48' CENTERS,


W/1/2" PREMOLDED JOINT FILLER

CEMENT CONC.
GUTTER DETAIL

SLOPING FACE WALL DESIGN


WITH 2:1 BACKSLOPE
@

3" CLR.

#4@ 1'- 6" MAX.(TYP.)


WITH 2' - 0" LAP SPLICE
AND EXTENDING THRU
CONSTRUCTION JOINT
FOR QTY. SEE TABLE

I
I

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL

#4@ 1'- 6" CENTERS (MAX.)


ONLY USED WHEN H =

1------ Cv - - - 1

SEE BAR@TABLE

26'

SEE KEY
DETAIL

FRONT

I
SPLIT VIEW
LINE

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

I
BACK

1 1/2" CLR.

SPLIT ELEVATION VIEW

1----------B-------1

(SHOWING SEPARATE REBAR LAYERS)

TYPICAL SECTION
BAR@ #4
LOCATION

TOP
OF
FOOTING

BOTTOM
OF
FOOTING

WALL
HEIGHT
(H)

QTY.

.s. 14'
15' .S.20'
21' .S.24'
25' .s.29'
30' .S.35'

4
6
7
9
11

.s. 14'
15' .S.20'
21' .S.24'
25' .S.29'
30' < 35'

4
6
7
9
11

9" MIN.
OFFSET - SET TOP OF WALL BACK:
H.s.20' .......... OFFSET= 1/2"
H ~ 20' .......... OFFSET (inches) = H {ft)

.,:~

1~~

8 -2

1
[

"-.\;;.:~

"C~R. ~~1'-0"
r-:---=-

BOTTOM OF FOOTING
S

(TYP.)

FRONT FACE OF WALL


AT TOP OF FOOTING

#4@ 1'- 6" SPACING

REINFORCED CONCRETE
RETAINING WALL
TYPE&
STANDARD PLAN D-10.35-00

3"

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

KEY DETAIL
REQUIRED ON WALLS WHERE H ~ 26'

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

07-08-08
DATE

Washington State Department of Transportation

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

4'- 3"
4'- 3"
4'- 3"
4'- 3"
4'- 3"
4'- 3"
4'- 9"
5'- 6"
6'- 0"
6'- 6"
7'- 3"
7'- 9"
8'- 3"
9'- 0"
9'- 9"
10'- 3"

~
2'- 9"
2'- 9"
2'- 9"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 3"
3'- 6"
3'- 6"
3'- 9"
3'- 9"
4'- 0"
4'- 3"
4'- 6"
4'- 9"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

11'- 0"
12'- 0"
12'- 3"
13'- 0"
13'- 9"
13'- 9"
14'- 3"
14'- 9"
15'- 6"
16'- 6"
16'- 9"
17' - 3"
17'- 9"
18'- 9"
19'- 3"

5'5'5'5'6'6'7'7'7'8'8'8'8'9'9'-

0"
3"
6"
9"
3"
6"
0"
3"
6"
0"
3"
6"
9"
3"
6"

BAR@#4

BAR@

BAR

hk

LENGTH

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 9"
1'- 9"
2'- 0"
2'- 3"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1' - 1 1/2"
1'- 3"
1'- 4"
1'- 5"
1'-61/2"
1' - 7 1/2"
1'-81/2"
1'- 10"
1' - 11"
2'- 0"
2'- 1"
2'- 2"
2'- 3"
2'- 4 1/2"
2'- 5"
2'- 6"

3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3' -7"
3' -7"
3' -7"
3' -7"
3'- 10"
3'- 10"
4'- 1"
4'- 1"
4'- 4"
4' -7"

2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
2'- 9"
3'- 0"
3'- 0"
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 6"
3'- 9"
4'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
9"
9"
7"
6"
6"

4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 6"
5'- 3"
5'- 9"
6'- 3"
7'- 0"
7'- 6"
8'- 0"
8'- 9"
9'- 6"
10'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"

4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 0"
4'- 6"
5'- 3"
5'- 9"
6'- 3"
7'- 0"
7'- 6"
8'- 0"
8'- 9"
9'- 6"
10'- 0"

2'2'2'2'2'2'2'3'3'3'3'3'4'4'4'-

N/A
N/A
N/A
N/A
N/A

2'- 7 1/2"
2'- 8 1/2"
2'- 9 1/2"
2'- 10 1/2"
2'-111/2"
3'- 1"
3'- 2"
3'- 3"
3'- 4"
3'- 5"
3'- 6"
3' -7"
3'- 7 1/2"
3'- 9"
3'- 10"

4' -7"
4' -7"
4'- 10"
4'- 10"
5'- 1"
5'- 1"
5'- 1"
5'- 4"
5'- 4"
5' -7"
5'- 10"
6'- 1"
6'- 4"
6'- 4"
6' -7"

4'- 0"
4'- 0"
4'- 3"
4'- 3"
4'- 6"
4'- 6"
4'- 6"
4'- 9"
4'- 9"
5'- 0"
5'- 3"
5'- 6"
5'- 9"
5'- 9"
6'- 0"

#5
#6
#6
#6
#6
#6
#6
#6
#6
#7
#7
#7
#7
#7
#7

7"
8"
8"
7"
7"
7"
7"
7"
6"
7"
7"
7"
7"
6"
6"

10'- 9"
11'- 9"
12'- 0"
12'- 9"
13'- 6"
13'- 6"
14'- 0"
14'- 6"
15'- 3"
16'- 3"
16'- 6"
17'- 0"
17'- 6"
18'- 6"
19'- 0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
11"
10"
10"
9"
9"
8"
7"

10'- 9"
11'- 9"
12'- 0"
12'- 9"
13'- 6"
13'- 6"
14'- 0"
14'- 6"
15'- 3"
16'- 3"
16'- 6"
17'- 0"
17'- 6"
18'- 6"
19'- 0"

3"
3"
6"
6"
9"
9"
9"
0"
0"
3"
6"
9"
0"
0"
3"

2'2'2'2'2'2'2'2'2'2'-

0"
0"
0"
0"
0"
0"
0"
0"
0"
0"

SIZE SPA.

LENGTH

SIZE SPA.

Jn~
h

~k
BAR@
@ 1' - 6" CENTERS

0::

III
...I
...I

iii

BAR@

BAR@

LENGTH

#6
#6

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
9"
7"
6"
8"
7"
6"
7"
6"

5' - 1 1/2"
6' - 1 1/2"
7' - 1 1/2"
8' - 1 1/2"
9' - 1 1/2"
10'- 1 1/2"
11'-11/2"
12'- 1 1/2"
13'- 1 1/2"
14' - 1 1/2"
15'- 1 1/2"
16'- 2 1/2"
17'- 2 1/2"
18'- 2 1/2"
19'- 4"
20'- 4"

4' -7"
5' -7"
6' -7"
7'- 7"
8' -7"
9' -7"
10'- 7"
11'- 7"
12'- 7"
13'- 7"
14'- 7"
15'- 7"
16'- 7"
17'- 7"
18'- 7"
19'- 7"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
9"
9"
9"
11"
11"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

#7
#7
#7
#7
#7
#8
#8
#8
#8
#9
#9
#10
#10
#10
#10

1'- 4"
1'- 0"
1'- 0"
10"
10"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"

10'- 3 1/2"
9'- 3 1/2"
10'- 5"
10'- 0 1/2"
11'-11/2"
14' - 5 1/2"
15'- 5 1/2"
15'- 7"
15'- 4"
13'- 5 1/2"
14' - 6 1/2"
16'- 3"
15'- 5 1/2"
16'- 4"
16'- 2 1/2"

9'- 4 1/2"
8'- 4 1/2"
9'- 6"
9' - 1 1/2"
10'- 3"
13'- 5"
14' - 5 1/2"
14' - 6 1/2"
14' - 3 1/2"
12'- 3"
13'- 4"
14'- 10 1/2"
14'- 1"
15'- 1"
14'- 11 1/2"

1' - 1"
1' - 1"
1' - 1"
1' - 1"
1' - 1"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#7
#7
#7
#7
#7
#8
#8
#8
#8
#9
#9
#10
#10
#10
#10

SIZE SPA.
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

#5
#5
#5

BAR

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

1'- 4"
1'- 0"
1'- 0"
10"
10"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"

6'- 2"
6'- 2"
6'- 5"
6'- 5"
6'- 8"
7'- 9"
7'- 9"
8'- 0"
8'- 0"
9' -7"
9'- 10"
11'- 5 1/2"
11'- 8 1/2"
11'- 8 1/2"
11'-111/2"

5'- 2"
5'- 2"
5'- 5"
5'- 5"
5'- 8"
6'- 8"
6'- 8"
6'- 11"
6'- 11"
8'- 3"
8'- 6"
10'- 0"
10'- 3"
10'- 3"
10'- 6"

1' - 1"
1' - 1"
1' - 1"
1' - 1"
1' - 1"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 6"
1'- 8"
1'- 8"
1'- 8"
1'- 8"

#7
#7
#7
#7
#7

SIZE SPA.

MATERIAL MAXIMUM SOIL PRESSURE (PSF)


QUANTITY

@#4

SERVICE STRENGTH

EXTREME
EVENT I

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 9"
4'- 9"
5'- 9"
6'- 9"
7'- 10 1/2"
8'- 9 1/2"
9'- 6 1/2"
10'- 6 1/2"
11'- 6 1/2"
12'- 6 1/2"
13'- 3 1/2"
14'- 3 1/2"
15'- 0 1/2"
16'- 1"
16'- 10"
17'- 7"

0.30
0.34
0.39
0.44
0.50
0.56
0.67
0.77
0.86
0.96
1.12
1.22
1.39
1.52
1.73
1.93

20.5
23.0
24.1
26.6
27.7
31.5
36.8
38.8
46.2
54.5
62.7
72.1
80.1
93.9
110.7
123.5

591
709
815
887
998
1145
1368
1540
1664
1875
1987
2202
2348
2441
2556
2702

771
925
1061
1146
1354
1580
1892
2125
2305
2604
2754
3058
3265
3391
3545
3752

733
871
992
1066
1236
1412
1686
1899
2049
2310
2450
2716
2894
3010
3153
3331

1'- 4"
1'- 0"
1'- 0"
10"
10"
1'- 4"
1'- 4"
1'- 2"
1'- 0"
10"
10"
1'- 0"
10"
10"
9"

18'- 6"
19'- 6"
20'- 3"
21'- 3"
22'- 0"
23'- 0"
24'- 0"
24'- 9"
25'- 9"
26'- 6"
27'- 3"
28'- 0"
28'- 9"
29'- 9"
30'- 6"

18'- 7"
19'- 7"
20'- 4"
21'- 4"
22'- 1"
23'- 1"
24'- 1 1/2"
24'- 10 1/2"
25'- 10 1/2"
26'- 7 1/2"
27'- 4 1/2"
28'- 1 1/2"
28'- 10 1/2"
29' -10 1/2"
30'- 7 1/2"

2.09
2.27
2.48
2.66
2.94
3.27
3.44
3.71
3.92
4.28
4.56
4.88
5.21
5.50
5.86

125.5
153.1
160.1
184.9
197.0
194.2
201.9
222.8
255.3
341.4
353.0
387.7
442.0
471.7
516.0

2800
2876
3046
3147
3190
3248
3298
3450
3556
3591
3760
3910
4060
4072
4221

3886
3983
4229
4368
4424
4543
4620
4832
4976
5010
5254
5464
5675
5680
5889

3454
3552
3756
3883
3933
3997
4054
4238
4370
4414
4616
4799
4982
4997
5179

SIZE SPA.

#8
#8
#8
#8
#9
#9
#10
#10
#10
#10

Q)

SLOPING FACE WALL DESIGN


WITH 2:1 BACKSLOPE

l
J

10

11/2"R

fJ)

LENGTH

STEM REINFORCEMENT

RADIUS
(SEE TABLE)

~b~
BAR

RADIUS

#4

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#5

#6
#7
#8
#9
#10
#11

BAR
#4

#5

#6
#7
#8
#9
#10

MIN. SPLICE

2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPE&
STANDARD PLAN D-10.35-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

07-08-08
DATE

Washington State Department of Transportation

en

NOTES

w
a:
w

FRONT

BACK

1. All concrete shall be Class 4000, except as noted.

[I]

....1
....1

SPLIT VIEW
LINE

FACE OF WALL

iii

48' WALL SECTION


(BETWEEN JOINTS)

250 PSF EQUIVALENT LIVE LOAD


SURCHARGE WHEN
SPECIFIED IN CONTRACT

2. For backfill requirements, see Standard Plan


D-4.

48' WALL SECTION

(BETWEEN JOINTS)

Cl

24' MIN. VERTICAL CURVE AT


ALL ANGLE OR (BREAK) POINTS
IN TOP OF WALL PROFILE

J__

3"CLR.~

4. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.20 g.
5. If Traffic Barriers are required, See Standard Plans
D-15.10, D-15.20 and D-15.30.

@#4

SURFACE TREATMENT

3. Concrete in the 48 foot wall sections shall be


placed separately between expansion joints with
a minimum 24 hour period before placing concrete
in the adjacent section.

#4@ 1' -6"


CENTERS

1 1/2" CLR.

EXPANSION JOINT - 48' CENTERS,


WI 1/2" PREMOLDED JOINT FILLER

VERTICAL FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

#4@ 1'- 6" MAX.(TYP.)


WITH 2' - 0" LAP SPLICE
AND EXTENDING THRU
CONSTRUCTION JOINT

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL

"-II:

1 1/2" CLR.

B ----------1

SEE BAR@TABLE

FRONT

I
I

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

I
BACK

TYPICAL SECTION

BAR@ #4
WALL
HEIGHT
(H)

QTY.

TOP
OF
FOOTING

!5.. 16'
16' < 23'
23' < 28'
29' < 35'

5
7
9
11

BOTTOM
OF
FOOTING

!5.. 16'
16' < 23'
23' < 28'
29' < 35'

5
7
9
11

LOCATION

SPLIT ELEVATION VIEW


OFFSET - SET TOP OF WALL BACK:
H-=:_20' .......... OFFSET= 1/2"
H.::_ 20' .......... OFFSET (inches) = H (ft)

---a- 2

<2) WHEN THE CONTRACT SPECIFIES


CABLE FENCE, BACKFILL AND THE
CEMENT CONCRETE GUTTER SHALL
BE PLACED 6" MIN. FROM THE TOP
OF THE WALL

(SHOWING SEPARATE REBAR LAYERS)

REINFORCED CONCRETE
RETAINING WALL
TYPE7
STANDARD PLAN D-1 0.40-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


12-02-08
----DESIGN
- -ENGINEER
----STATE
DATE

.....

fll

Washington State Department of Transportation

FOOTING REINFORCEMENT
DIMENSIONS

WALL
HT
H
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

6'- 6"
6'- 6"
6'- 6"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 3"
8'- 9"
9'- 3"
9'- 9"
10'- 3"
10'- 6"
11'- 0"

~
2'- 0"
2'- 0"
2'- 3"
2'- 3"
2'- 3"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 6"
2'- 6"
2'- 9"
3'- 0"
3'- 3"
3'- 6"
3'- 6"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

11'- 6"
12'- 0"
12'- 9"
13'- 0"
13'- 6"
14'- 3"
14'- 9"
15'- 3"
16'- 0"
16'- 6"
17'- 0"
17'- 6"
18'- 3"
18'- 9"
19'- 3"

3'4'4'4'4'4'5'5'5'5'6'6'6'6'7'-

9"
0"
3"
3"
6"
9"
0"
3"
6"
9"
0"
3"
6"
9"
0"

BAR@#4

BAR@

BAR

LENGTH

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 3"
1'- 3"
1'- 3"

1'- 4"
1' - 5 1/2"
1' - 6 1/2"
1' - 7 1/2"
1'- 9"
1'- 10"
1'-111/2"
2'- 0 1/2"
2' - 1 1/2"
2'- 3"
2'- 4"
2'- 5"
2'- 6 1/2"
2' - 7 1/2"
2'- 8 1/2"
2'- 10"

3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3'- 4"
3' -7"
3' -7"
3' -7"
3' -7"
3' -7"

2'2'2'2'2'2'2'2'2'2'2'3'3'3'3'3'-

9"
9"
9"
9"
9"
9"
9"
9"
9"
9"
9"
0"
0"
0"
0"
0"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#6
#6

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
9"
9"
8"
7"
8"
8"
8"
7"
10"
7"

6'
6'
6'
6'
6'
7'
7'
7'
7'
8'
8'
9'
9'
10'
10'
10'

3"
3"
3"
6"
9"
0"
3"
6"
9"
0"
6"
0"
6"
0"
3"
9"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
10"
10"
8"
8"
8"
8"
10"
8"
7"

6'
6'
6'
6'
6'
7'
7'
7'
7'
8'
8'
9'
9'
10'
10'
10'

3"
3"
3"
6"
9"
0"
3"
6"
9"
0"
6"
0"
6"
0"
3"
9"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#6
#6

1'- 3"
1'- 6"
1'- 6"
1'- 9"
1'- 9"
2'- 0"
2'- 0"
2'- 3"
2'- 3"
2'- 6"
2'- 6"
2'- 9"
3'- 0"
3'- 0"
3'- 3"

2'- 11"
3'- 0"
3'- 1"
3'- 2"
3'- 3 1/2"
3'- 4"
3'- 5 1/2"
3'- 6 1/2"
3'- 7 1/2"
3'- 8 1/2"
3'- 9 1/2"
3'- 10 1/2"
3' - 11 1/2"
4'- 0 1/2"
4'- 1 1/2"

3' -7"
3'- 10"
3'- 10"
4'- 1"
4'- 1"
4'- 4"
4'- 4"
4' -7"
4' -7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5'- 4"
5' -7"

3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 6"
3'- 9"
3'- 9"
4'- 0"
4'- 0"
4'- 3"
4'- 3"
4'- 6"
4'- 9"
4'- 9"
5'- 0"

#6
#6
#6
#6
#6
#7
#7
#7
#7
#7
#7
#7
#8
#8
#8

7"
7"
6"
6"
6'
7"
7"
6"
6"
6"
6"
6"
7"
7"
7"

11'
11'
12'
12'
13'
14'
14'
15'
15'
16'
16'
17'
18'
18'
19'

3"
9"
6"
9"
3"
0"
6"
0"
9"
3"
9"
3"
0"
6"
0"

#5
#5
#5
#5
#6
#6
#6
#6
#6
#6
#6
#7
#7
#7
#7

6"
7"
6"
6"
8"
7"
7"
7"
6"
6"
6"
7"
7"
7"
7"

11'
11'
12'
12'
13'
14'
14'
15'
15'
16'
16'
17'
18'
18'
19'

3"
9"
6"
9"
3"
0"
6"
0"
9"
3"
9"
3"
0"
6"
0"

#5
#5
#5
#5
#5
#5
#5
#6
#6
#6
#6
#6
#6
#6
#7

LENGTH

SIZE SPA.

BAR@

BAR

SIZE SPA.

STEM REINFORCEMENT

LENGTH

LENGTH

1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
10"
9"
8"
7"
10"
10"
8"
8"
10"
9"

5' - 2"
6' - 2"
7' - 2 1/2"
8' - 2 1/2"
9' - 2 1/2"
10' - 2 1/2"
11'- 21/2"
12' - 2 1/2"
13' - 2 1/2"
14' - 2 1/2"
15'- 4"
16'- 4"
17' - 4"
18'- 4"
19'- 5 1/2"
20'- 5 1/2"

4'- 7 1/2"
5'- 7 1/2"
6'- 7 1/2"
7'- 7 1/2"
8'- 7 1/2"
9'- 7 1/2"
10'- 8"
11'- 8"
12'- 8"
13'- 8"
14'- 8"
15'- 8"
16'- 8"
17' - 8"
18'- 8 1/2"
19'- 8 1/2"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
10"
10"
1'- 0"
1'- 0"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

8"
8"
8"
8"
8"
8"
8"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
8"
8"

4'- 8 1/2"
4'- 1"
6'- 5"
5'- 9"
8'- 0"
7'- 4 1/2"
9' -7"
8'- 11"
11'-11/2" 10'- 5 1/2"
12'- 7"
11'-111/2"
14' - 0 1/2" 13'- 4 1/2"
16'- 4"
15'- 6 1/2"
17'- 8 1/2"
16'-11"
19'- 1"
18'- 3 1/2"
20'- 5"
19'- 7 1/2"
21'- 8 1/2" 20'-111/2"
21'- 2"
20'- 5"
19'- 10 1/2" 19'- 1 1/2"
21'- 9 1/2" 20'- 10 1/2"

10"
10"
10"
10"
10"
10"
10"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 2"

#5
#5
#5
#5
#5
#5
#5

SIZE SPA.

LENGTH

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

8"
8"
8"
8"
8"
8"
8"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
8"
8"

3'- 10 1/2"
4' - 1 1/2"
4' - 1 1/2"
4'- 4 1/2"
4'- 4 1/2"
4'- 7 1/2"
4'- 7 1/2"
5'- 5 1/2"
5'- 5 1/2"
5'- 8 1/2"
5'- 8 1/2"
5' - 11 1/2"
6'- 2 1/2"
6'- 2 1/2"
7'- 3"

3'- 2"
3'- 5"
3'- 5"
3'- 8"
3'- 8"
3'- 11"
3'- 11"
4' -7"
4' -7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5'- 4"
6'- 3"

10"
10"
10"
10"
10"
10"
10"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 2"

#5
#5
#5
#5
#5
#5
#5
#6
#6
#6
#6
#6
#6
#6
#7

SIZE SPA.

#6
#6
#6
#6
#6
#6
#6
#7

BAR

Q)

@#4

MATERIAL
QUANTITY

MAXIMUM SOIL PRESSURE (PSF)


EXTREME
EVENT 1

EXTREME
EVENT2

1260
1350
1443
1631
1836
2060
2303
2455
2728
3022
3261
3403
3514
3625
3809
4043

1108
1272
1384
1572
1781
2011
2264
2400
2685
2995
3287
3466
3585
3705
3864
4169

1623
1850
2049
2217
2402
2604
2822
2958
3202
3462
3570
3628
3658
3700
3859
4012

4152
4296
4335
4672
4782
4855
4966
5112
5162
5308
5421
5568
5660
5774
5922

4288
4481
4561
4990
5112
5268
5393
5600
5686
5897
6027
6242
6421
6554
6776

4067
4169
4151
4448
4520
4562
4642
4765
4789
4916
5005
5134
5215
5307
5440

SERVICE STRENGTH

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

4'- 4"
5'- 4"
6'- 4"
7'- 4"
8'- 4"
9'- 4"
10'- 4"
11'- 4"
12'- 4"
13'- 4"
14'- 4"
15'- 1"
16'- 1"
17'- 1"
18'- 1"
19'- 1"

0.40
0.45
0.51
0.58
0.65
0.72
0.80
0.88
0.96
1.05
1.16
1.33
1.44
1.56
1.66
1.79

25.7
28.2
29.3
33.8
39.6
43.6
48.8
53.0
59.7
65.9
77.5
82.0
93.3
102.9
115.4
132.9

915
992
1046
1176
1318
1471
1636
1733
1915
2109
2277
2377
2453
2530
2642
2808

8"
8"
8"
8"
8"
8"
8"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
8"
8"

20'- 3 1/2"
21'- 0 1/2"
22'- 0 1/2"
22'- 9 1/2"
23'- 9 1/2"
24'- 6 1/2"
25'- 6 1/2"
26'- 4"
27'- 4"
28'- 1"
29'- 1"
29'- 10"
30' -7"
31'- 7"
32'- 4"

20'- 1"
20'- 10"
21'- 10"
22' -7"
23' -7"
24'- 4"
25'- 4"
26'- 1"
27' - 1"
27'- 10"
28'- 10"
29' -7"
30'- 4"
31'- 4"
32'- 1"

1.92
2.13
2.28
2.50
2.65
2.93
3.09
3.36
3.55
3.85
4.03
4.35
4.70
4.90
5.25

148.7
152.3
170.8
178.0
190.1
212.7
221.6
238.4
255.7
263.4
273.8
291.4
327.3
358.8
423.0

2883
2985
3026
3252
3328
3395
3472
3576
3623
3727
3805
3910
3989
4067
4173

SIZE SPA.

REINFORCEMENT NOTES

(D

VERTICAL FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

IF TRAFFIC BARRIER IS USED, ADD 0.100 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 1.
ADD 0.123 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

@ADD 28 LB/LF OF REINFORCING STEEL FOR BARRIER ALTERNATE 1 OR 19 LB/LF OF REINFORCING STEEL
FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

RADIUS
(SEE TABLE)

BAR

BAR@

en
z

w
0::
w

[I]

....1
....1

1Ii

@ 1' - 6" CENTERS

BAR

RADIUS

#4
#5
#6
#7
#8
#9
#10
#11

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#4
#5
#6
#7
#8
#9
#10

MIN. SPLICE
2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPE7
STANDARD PLAN D-1 0.40-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

Cl

BARS@ AND@

.....
VI

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

NOTES

en
z

FRONT

w
a:
w

BACK

1. All concrete shall be Class 4000, except as noted.

SPLIT VIEW
LINE

FACE OF WALL

[I]

....1
....1

iii

48' WALL SECTION


(BETWEEN JOINTS)

250 PSF EQUIVALENT LIVE


LOAD SURCHARGE WHEN
SPECIFIED IN CONTRACT

.1.

48' WALL SECTION


(BETWEEN JOINTS)

3. Concrete in the 48 foot wall sections shall be


placed separately between expansion joints with
a minimum 24 hour period before placing concrete
24' MIN. VERTICAL CURVE AT
in the adjacent section.
ALL ANGLE OR (BREAK) POINTS

Cl

~---------------------..r.~~~~~~~~

IN TOP OF WALL PROFILE

4. This wall has been designed in accordance with


the requirements of the AASHTO LRFD Bridge
Design Specifications 4th Edition 2007 and interims
through 2008. The seismic design of these walls
has been completed using an effective PGA
of 0.20 g.

CEMENT CONC. GUTTER


(CL. 3000, 4" THICK)

@#4

SURFACE TREATMENT

2. For backfill requirements, see Standard Plan


D-4.

5. If Traffic Barriers are required, See Standard Plans


D-15.10, D-15.20 and D-15.30.
#4@ 1' -6"
CENTERS

1 1/2" CLR.

EXPANSION JOINT - 48' CENTERS,

WI 1/2" PREMOLDED JOINT FILLER

SLOPING FACE WALL DESIGN


WITH A 250 PSF SURCHARGE
OR TRAFFIC BARRIER

3" DIAM. DRAINS AT ABOUT


12' CENTERS AND 6" ABOVE
FINAL GROUND LINE AT
FRONT FACE OF WALL
SEE BAR@TABLE

FRONT

WALL
HEIGHT
(H)

< 12'
TOP
OF
FOOTING

BOTTOM
OF
FOOTING

BACK

TYPICAL SECTION

BAR@ #4
LOCATION

CONSTRUCTION JOINTS IN FOOTING


AT 120' CENTERS MAX.

SPLIT VIEW
LINE

QTY.

13' .:5.. 16'


17' .:5..22'
23' < 28'
29' < 35'

5
6
7
9
11

< 12'
13' < 16'
17' < 22'
23' < 28'
29' < 35'

5
6
7
9
11

OFFSET - SET TOP OF WALL BACK:


H~20' .......... OFFSET= 1/2"
H~20' .......... OFFSET (inches)= H(ft)

WHEN THE CONTRACT SPECIFIES


CABLE FENCE, BACKFILL AND THE
CEMENT CONCRETE GUTTER SHALL
BE PLACED 6" MIN. FROM THE TOP
OF THE WALL

SPLIT ELEVATION VIEW


(SHOWING SEPARATE REBAR LAYERS)

-2

REINFORCED CONCRETE
RETAINING WALL
TYPES
STANDARD PLAN D-1 0.45-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

fll

.....

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department o Transportation

FOOTING REINFORCEMENT
WALL
HT
H

DIMENSIONS

5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

6'- 9"
6'- 9"
7'- 0"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 3"
8'- 9"
9'- 0"
9'- 6"
10'- 0"
10'- 6"
11'- 3"
11'- 6"

~
3'- 0"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 6"
3'- 6"
3'- 9"
3'- 9"
3'- 9"
3'- 9"
4'- 0"
4'- 3"
4'- 6"
5'- 0"
5'- 0"

21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

12'- 3"
12'- 9"
13'- 3"
13'- 9"
14'- 3"
15'- 0"
15'- 6"
16'- 0"
16'- 6"
17' - 3"
17'- 9"
18'- 3"
18'- 9"
19'- 3"
19'- 9"

5'5'6'6'6'6'7'7'7'8'8'8'8'9'9'-

6"
9"
0"
3"
6"
9"
0"
3"
6"
0"
3"
6"
9"
0"
3"

BAR@#4

BAR@

BAR

LENGTH

SIZE SPA.

1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 3"
1'- 3"
1'- 3"
1'- 6"
1'- 6"

1'- 4"
1'- 5 1/2"
1'- 6 1/2"
1'- 7 1/2"
1'- 9"
1'- 10"
1'-111/2"
2'- 0 1/2"
2'- 1 1/2"
2'- 3"
2'- 4"
2'- 5"
2'- 6 1/2"
2'- 7 1/2"
2'- 8 1/2"
2'- 9 1/2"

2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2' -7"
2'- 10"
2'- 10"
2'- 10"
3'- 1"
3'- 1"

2'2'2'2'2'2'2'2'2'2'2'2'2'2'2'2'-

0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
3"
3"
3"
6"
6"

1'- 9"
1'- 9"
2'- 0"
2'- 0"
2'- 3"
2'- 6"
2'- 6"
2'- 9"
2'- 9"
3'- 0"
3'- 3"
3'- 3"
3'- 6"
3'- 9"
4'- 0"

2'- 10 1/2"
2' - 11 1/2"
3'- 0 1/2"
3'- 1 1/2"
3'- 2 1/2"
3'- 3 1/2"
3'- 4 1/2"
3'- 5 1/2"
3' -7"
3'- 7 1/2"
3'- 8 1/2"
3'- 10"
3'- 10 1/2"
3' - 11 1/2"
4'- 0 1/2"

3'- 4"
3'- 4"
3' -7"
3' -7"
3'- 10"
4'- 1"
4'- 1"
4'- 4"
4'- 4"
4' -7"
4'- 10"
4'- 10"
5'- 1"
5'- 4"
5' -7"

2'2'3'3'3'3'3'3'3'4'4'4'4'4'5'-

9"
9"
0"
0"
3"
6"
6"
9"
9"
0"
3"
3"
6"
9"
0"

#4
#4
#4
#4
#4
#4
#4
#5
#5

LENGTH

SIZE SPA.

LENGTH

STEM REINFORCEMENT

BAR@
SIZE SPA.

BAR@

LENGTH

SIZE SPA.

BARQ)

LENGTH

SIZE SPA.

@#4

MATERIAL
QUANTITY

LENGTH

LENGTH

CONC.
CY/LF

STEEL
LBS/LF

MAXIMUM SOIL PRESSURE (PSF)


SERVICE STRENGTH

EXTREME
EVENT I

EXTREME
EVENT2

#6
#6
#6
#6
#7
#7
#7

1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
8"
6"
8"
7"
7"
6"
6"
6"
7"
7"
7"

6'- 6"
6'- 6"
6'- 9"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 6"
8'- 9"
9'- 3"
9'- 9"
10'- 3"
11'- 0"
11'- 3"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4

1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"

6'- 6"
6'- 6"
6'- 9"
6'- 9"
7'- 0"
7'- 3"
7'- 6"
7'- 9"
8'- 0"
8'- 6"
8'- 9"
9'- 3"
9'- 9"
10'- 3"
11'- 0"
11'- 3"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#5

1'- 6"
1'- 6"
1'- 6"
1'- 0"
1'- 0"
1'- 0"
10"
9"
8"
7"
6"
10"
9"
8"
7"
7"

5'- 2"
6'- 2"
7'- 2"
8'- 2"
9'- 2"
10'- 2"
11'- 2"
12'- 2"
13'- 2"
14'- 2"
15'- 2"
16'- 3"
17' - 3"
18'- 3"
19'- 3"
20'- 3"

4' -7"
5' -7"
6' -7"
7'- 7"
8' -7"
9' -7"
10'- 7"
11'- 7"
12'- 7"
13'- 7"
14'- 7"
15'- 7"
16'- 7"
17'- 7"
18'- 7"
19'- 7"

8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
10"
10"
10"

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

3'- 10 1/2"
4'- 10 1/2"
5'- 10 1/2"
6'- 10 1/2"
7'- 10 1/2"
8'- 10 1/2"
9'- 10 1/2"
10'- 11"
11'-11"
12'-11"
13'- 11"
14'- 8"
15'- 8"
16'- 8"
17' - 5"
18'- 5"

0.41
0.46
0.53
0.58
0.65
0.73
0.81
0.89
0.97
1.07
1.17
1.34
1.45
1.57
1.78
1.89

23.8
26.3
30.5
34.7
37.7
43.0
50.1
55.1
62.7
75.0
83.3
91.3
98.7
115.7
121.1
130.2

900
987
1076
1225
1325
1493
1677
1797
2004
2190
2420
2532
2630
2728
2715
2940

1244
1351
1476
1687
1833
2075
2341
2522
2826
3089
3430
3588
3730
3871
3838
4172

1140
1339
1488
1741
1911
2200
2526
2739
3126
3470
3928
4115
4284
4453
4366
4815

1620
1878
2006
2332
2486
2744
3027
3221
3545
3706
4064
4129
4194
4270
4131
4466

#7
#7
#7
#7
#7
#8
#8
#8
#8
#8
#8
#8
#8
#8
#9

6"
6"
6"
6"
6"
7"
7"
7"
6"
6"
6"
6"
6"
6"
7"

12'- 0"
12'- 6"
13'- 0"
13'- 6"
14'- 0"
14'- 9"
15'- 3"
15'- 9"
16'- 3"
17'- 0"
17'- 6"
18'- 0"
18'- 6"
19'- 0"
19'- 6"

#4
#4
#4
#4
#4
#4
#4
#4
#4
#4
#5
#5
#5
#5
#5

9"
9"
8"
8"
8"
7"
7"
6"
6"
6"
8"
8"
8"
8"
7"

12'- 0"
12'- 6"
13'- 0"
13'- 6"
14'- 0"
14'- 9"
15'- 3"
15'- 9"
16'- 3"
17'- 0"
17'- 6"
18'- 0"
18'- 6"
19'- 0"
19'- 6"

#5
#5
#5
#5
#5
#5
#5
#5

1'- 0"
1'- 0"
10"
10"
9"
9"
8"
7"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
10"
8"

7' - 9 1/2"
8'-111/2"
8' -7"
9'- 8 1/2"
10'- 10"
11'- 0"
11'-11/2"
12'- 1 1/2"
14'- 0"
15'- 1"
16'- 1 1/2"
17'- 2 1/2"
18'- 3 1/2"
17'- 9"
16'- 7"

7' - 1 1/2"
8'- 3 1/2"
7'- 11"
9'- 0 1/2"
10'- 2"
10'- 4"
10'- 5 1/2"
11'- 6"
13'- 2 1/2"
14'- 4"
15'- 4"
16'- 5 1/2"
17'- 6 1/2"
17'- 0"
15'- 9 1/2"

10"
10"
10"
10"
10"
10"
10"
10"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"

#5
#5
#5
#5
#5
#5
#5
#5
#6
#6
#6
#6
#6
#6
#6

1'- 0"
1'- 0"
10"
10"
9"
9"
8"
7"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
10"
8"

4'- 4 1/2"
4'- 4 1/2"
4'- 7 1/2"
4'- 7 1/2"
4'- 10 1/2"
5'- 1 1/2"
5'- 1 1/2"
5'- 4 1/2"
5'- 11"
6'- 2"
6'- 5"
6'- 5"
6'- 8"
6'- 11"
7'- 2"

3'- 7 1/2"
3'- 7 1/2"
3'- 11"
3'- 11"
4'- 1 1/2"
4'- 4 1/2"
4'- 4 1/2"
4'- 7 1/2"
5'- 0 1/2"
5'- 4"
5' -7"
5' -7"
5'- 10"
6'- 0 1/2"
6'- 4"

10"
10"
10"
10"
10"
10"
10"
10"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
1'- 0"

#5
#5
#5
#5
#5
#5
#5
#5
#6
#6
#6
#6
#6
#6
#6

1'- 0"
1'- 0"
10"
10"
9"
9"
8"
7"
1'- 0"
1'- 0"
1'- 0"
1'- 0"
10"
10"
8"

19'- 7"
20' -7"
21'- 4"
22'- 4"
23'- 1"
23'- 10"
24'- 10"
25' -7"
26' -7"
27'- 4"
28'- 1"
29'- 1"
29'- 10"
30' -7"
31'- 4"

19'- 2 1/2"
20'- 2 1/2"
20'- 11 1/2"
21' -111/2"
22'- 8 1/2"
23'- 5 1/2"
24'- 5 1/2"
25'- 3"
26'- 3"
27'- 0"
27'- 9"
28'- 9"
29'- 6"
30'- 3"
31'- 0"

2.12
2.26
2.50
2.65
2.91
3.20
3.37
3.66
3.84
4.17
4.49
4.69
5.03
5.38
5.74

141.8
148.6
162.3
172.2
179.4
200.1
213.7
234.3
245.8
255.9
269.6
278.2
301.9
308.1
353.2

2930
3028
3145
3243
3360
3445
3544
3661
3760
3770
3888
3986
4105
4223
4342

4143
4284
4448
4589
4753
4856
4996
5161
5301
5303
5469
5609
5774
5940
6106

4734
4905
5104
5276
5476
5603
5776
5977
6150
6116
6319
6491
6694
6898
7102

4358
4466
4600
4714
4854
4917
5039
5186
5310
5291
5443
5571
5725
5879
6034

#6
#6
#6
#6
#6
#6
#6

REINFORCEMENT NOTES

(D

IF TRAFFIC BARRIER IS USED, ADD 0.110 CY OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 1.
ADD 0.152 CY/LF OF CONCRETE CLASS 4000 FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

l
J

@ADD 16 LB/LF OF REINFORCING STEEL FOR BARRIER ALTERNATE 1 OR 23 LB/LF OF REINFORCING STEEL
FOR BARRIER ALTERNATE 2. SEE STANDARD PLAN D-15.10

Jn~
h

10

11/2"R

~k
BAR@
en
z

w
c:::
w

[I]

....1
....1

1ii

@ 1' - 6" CENTERS

SLOPING FACE WALL DESIGN


WITH A 250 PSF SURCHARGE

RADIUS
(SEE TABLE)

~b~
BAR

RADIUS

#4
#5

1 1/2"
1 7/8"
2 1/4"
2 5/8"
3"
4 3/4"
5 3/8"
6"

#6
#7
#8
#9
#10
#11

BAR
#4
#5

#6
#7
#8
#9
#10

MIN. SPLICE
2'2'2'2'3'4'5'-

0"
0"
0"
6"
3"
2"
3"

REINFORCED CONCRETE
RETAINING WALL
TYPES
STANDARD PLAN D-1 0.45-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

Cl

BARS@ AND@

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

en
z

8'- 0" SPACING BETWEEN JOINTS


(TYPICAL)

DUMMY JOINT- SEE DETAIL, DUMMY JOINT TO


BE OMITTED ON BACK FACE OF BARRIER \

w
w

a:

[I]

~f~===. ~.....===..~.....~..~.....~..~... ~..~.... ~


.. ~
..... IF...~.~
..... ~
..~.~~
..~
... ~
.. ..... ~.~/:?-~.~
. . . ~.~. . .:. . . .:. . .:. . .:. . . .:. . .~.'!IF'

....1
....1

iii

'I'

~.~~.~~.~ ~.~~~~~.===~.~~~~.::::::::::~==~~~Ib=J/.,.;-_jl------=-~~~

....:.......:.......:...... ...... ...... ..... : ...... ..... .. ..... ..===


..... ...... ..... .. .....

=11F
..

~ CONTINUOUSV

'I

8'- 0"

CURB LINE

IF=.

_j

4'- 0"

_I

1---------11

Cl

PLAN

~
@#4-CONT.

2@#6- CONT.

WI 2' - 0" LAP SPLICE

WI 3' - 8" LAP SPLICE

TOP OF RETAINING WALL

Co

'

RETAINING WALL
REINFORCING STEEL

SECTION

ELEVATION

SECTION
CONSTRUCTION JOINT - LEVEL TRANSVERSE WITH
ROUGHENED SURFACE

TRAFFIC
BARRIER
TOP OF
ROADWAY

2'- 6"
4"

T
r-.

-Hr.-

<2) ATTACH GUARDRAIL TO CONCRETE


TRAFFIC BARRIER WITH 718" DIAM.
HIGH STRENGTH BOLTS {STANDARD
SPECIFICATION 9-06.5{4)) WITH
THIN SLAB FERRULE INSERTS
OR RESIN BONDED ANCHORS.
SEE THE CONTRACT PLANS.

...

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.10-01

...... lt)

DETAIL

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

BEAM GUARDRAIL TRANSITION TYPE 20 CONNECTION

BEAM GUARDRAIL TRANSITION TYPE 21 CONNECTION

F-SHAPE TRAFFIC BARRIER ON RETAINING WALL

PERSPECTIVE VIEW

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

en
z

w
w

a:
[I]

....1
....1

iii

REINFORCING STEEL BENDING DIAGRAM

VARIES

Cl

NOTE
SEE ELEVATION FOR LAP
SPLICE REQUIREMENTS

H~
60

..,

_l_r-0

......

--~--~--/

nt

USED WITH SLOPED FACE


RETAINING WALL

USED WITH VERTICAL FACE


RETAINING WALL

USED WITH SLOPED FACE


RETAINING WALL

USED WITH VERTICAL FACE


RETAINING WALL

@
ALL DIMENSIONS ARE OUT TO OUT

CONSTRUCTION JOINT- LEVEL TRANSVERSE WITH


ROUGHENED SURFACE

1 112"114"

~~-~4~'-~0"--.~!4~----~8'-~0"______.\~

n~

:::!:
("')
("')

JL

H
R

=1/4"

SEE STD. SPEC. FOR BENDING DIAMETERS

1/4" TO 1/2" DEEP


IRRE~ULAR FRACTURE

1"1/4"

PLAN VIEW

FRACTURED FIN FINISH DETAIL

DUMMY JOINT DETAIL

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.10-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


.....
fll

STATE DESIGN ENGINEER

12-02-08
DATE

"
"
Wash1ngton
State Department o fT ransportat1on

..

DUMMY JOINT- SEE DETAIL, DUMMY JOINT TO


BE OMITTED ON BACK FA~E OF BARRIER \

en
z

w
a:
w

[I]

8'

- 0" SPACING BETWEEN JOINTS


(TYPICAL)

.I.

8'

.I _j

- 0"

....1
....1

iii

I
CURB LINE

~--1---4'_- ------~-1 ~ f

_j

0_"

PLAN

Cl

..

8' - 0" SPACING BETWEEN JOINTS (TYPICAL)

..

~.

8'- 0"

#5 @ 8" SPACING

I 10" I

@5"MAX.

~:
8j8j8~ ~ifQj8j8j8= 8j8j8j8j8j8= ejgjgjQj++n+a
l_j lllJ--l
b

1~.

@#5
RETAINING WALL
REINFORCING
STEEL

~L3~i:
~H
~!
=+
==t;; .

'41

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

!1

!1

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

I
I

@
@

CONSTRUCTION JOINT - LEVEL TRANSVERSE WITH


ROUGHENED SURFACE

TOP OF
ROADWAY
(TYP.)
~

t \ "---@&@#8

!1

!1

!1

I
I

rI rI rI rI rI

....J

SECTION

=2'- 6"

1 1/2" CLR.

II

~~~~~g ~~ I ~

R2 #5-6 SPACES

11~

@#4@ 1'- 4" SPACING

2@~\~\~\

____l_

#5 @ 8" SPACING

8"

(
i

!1

-@#5, @&@ #4
- 4 SPACES @ 8" 2'- 8"

SECTION

#4@ 1'- 4" SPACING

ELEVATION

TRAFFIC
BARRIER

2'- 6"

ATTACH GUARDRAIL TO CONCRETE


TRAFFIC BARRIER WITH 7/8" DIAM.
HIGH STRENGTH BOLTS (STANDARD
SPECIFICATION 9-06.5(4)) WITH
THIN SLAB FERRULE INSERTS
OR RESIN BONDED ANCHORS.
SEE THE CONTRACT PLANS.

RETAINING
WALL

DETAIL

1'- 3 1/2"

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.20-02

1'- 5 1/2"

SHEET 1 OF 2 SHEETS

ELEVATION

PERSPECTIVE VIEW

BEAM GUARDRAIL TRANSITION TYPE 20 CONNECTION

ELEVATION

BEAM GUARDRAIL TRANSITION TYPE 21 CONNECTION

SINGLE SLOPE TRAFFIC BARRIER ON RETAINING WALL

APPROVED FOR PUBLICATION

PERSPECTIVE VIEW

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

en
z

w
w

a:
[I]

....1
....1

REINFORCING STEEL BENDING DIAGRAM

iii
;>.:
[I]

rr1

Cl

1ft

I.

VARIES

:lr
~

(')

'

NOTE

@
@)

SEE ELEVATION FOR LAP


SPLICE REQUIREMENTS
USED WITH A SLOPED FRONT
FACE OF A RETAINING WALL

'

@)

('t)

('t)

n~

nt
@

R = 1/4"

USED WITH A VERTICAL FRONT


FACE OF A RETAINING WALL

10"

~~~

nt

I.

7'- 0"

.I~

5'- 0"

@
ALL DIMENSIONS ARE OUT TO OUT

CONSTRUCTION JOINT- LEVEL TRANSVERSE WITH


ROUGHENED SURFACE

1 1/2"114"

USED WITH A SLOPED FRONT


FACE OF A RETAINING WALL

USED WITH A VERTICAL FRONT


FACE OF A RETAINING WALL

---~

II
'

6"~

w~

SEE STD. SPEC. FOR BENDING DIAMETERS

1/4" TO 1/2" DEEP


IRRE~ULAR FRACTURE

1"1/4"

PLAN VIEW

FRACTURED FIN FINISH DETAIL

DUMMY JOINT DETAIL

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.20-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

en
z

w
a:
w

[I]

JOINT~n,-,.,. ,S,.E " 'D" "'"E~TA~IL~,~~~~~~~~~~~~~........,.,,.,.,..,~~~~~~~~~~~~~~~._._......,-""""""'

DUMMY JOINT TO BE OMITTED


ON BACK FACE OF BARRIER
DUMMY

BRIDGE RAILING TYPE BP

8' - 0" SPACING BETWEEN JOINTS


(TYPICAL)

~-~' j

8' - 0"

:.

"f ;

TOP OF
ROADWAY

....1
....1

iii

Cl

TRAFFIC
BARRIER

.....

~~---------------r------~~~--------------------~~~----------------------~
SIDEWALK

PLAN

CURB LINE

_ _ l _ __ _

RETAINING
WALL

- 0" SPACING BETWEEN JOINTS (TYPICAL)


@ #5 @ 8" SPACING

8'

5@)#4

~CONTINUOUS

2@)#6
\

- CONTINUOUS \

- 0"

1 1/2" CLR.

@#4@ 1'- 4" SPACING

8'

DETAIL

~-ilk<')~ ~~
---~----

--- ----

I I 1I
1 1 111111111Til iT
1_N111111111
~~~TT
-1---JI-1 1-1---JI -I-ll :-JI-1---JI-1---JI-1---JI-1---ll -I---JI-1---JI-1---JI-1---JI-I---ll-1- -I---JI-I---JI-I---JI-1---JI-1---ll-lil
-+----ll---+----ll---+----ll---+----ll---+----11---+---t

(~P.)

Du:MM)' JqiN1,

-Hr~~H

I \f\ I

I
I
I
I
I

1
1
1
1

I
I
I
I

1
1
1
1

I
I
I
I

1
1
1
1

-HrNrHrHrHrH
I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

BRIDGE RAILING
TYPE BP

FIELciiBEND

1
1
1
1

I
I
I
I
I

1
1
1
1

-HrHrHrHrHr~ -HrHrHrHrHrH~

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

1
1
1
1

I
I
I
I
I

-r

I
I
I
I

0,

tv>

Co

TOP OF
SIDEWALK

'

'

Ii

1f--r -i-~--~~-~- t,- r-~1- -~ -r -1,


1 I 1 I 1 I 1 I 1 I 1 I 1
1 I 1 I 1 I 1 I 1 I 1 I 1
1 I 1 I 1 I 1 I 1 I 1 I 1

~~

EE GUARDRAIL
ONNECTION
D ETAILS

CONSTRUCTION JOINT LEVEL TRANSVERSE


WI ROUGHENED SURFACE

RETAINING WALL
REINFORCING STEEL

....J

#5 @ 8" SPACING
@#4@ 1' -4" SPACING

SECTION

ELEVATION

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.30-01

PLAN VIEW

DUMMY JOINT DETAIL

FRACTURED FIN FINISH DETAIL

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

OBLIQUE VIEW

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

en

BRIDGE RAILING
TYPEBP \

w
a:
w

[I]

....1
....1

iii

'

TOP OF SIDEWALK \

Cl

'

:::

:::

000
000
00

lr

......................... lUI ....

FOR GUARDRAIL CONNECTION DETAIL {HOLE PATTERN)

NOTE

AND HARDWARE REQUIRED - SEE BEAM GUARDRAIL

TRANSITION TYPE 21 CONNECTION, THIS SHEET

FOR GUARDRAIL DETAILS NOT SHOWN - SEE BEAM GUARDRAIL


{TYPE 31) TRANSITION SECTION TYPE 22, STANDARD PLAN C-25.22

BRIDGE TRANSITION
RAMP {HMA)

<
o
I I+<
l

'

o o

"iTt-'

ll

f:l

:l

''

liT

'
'

--~

o o

- 11"

--------7

000
000
00

. .. .. .. . .. .. . .. . .. .. .. . .. .. .. . .. .. .. . .. .. .. . .. .. .. . .. .. .. .

v
:'\
2'

I
I

'
'
'
'
'

'r,l
'
'
'
'

F-.

'

!V

'
'
'
'
'
'

'
'
'
'
'
'

SIDEWALK@ RETAINING WALL

BEAM GUARDRAIL TRANSITION TO BRIDGE END CONNECTION


2'- 11"
8"

FOR GUARDRAIL DETAILS NOT SHOWN


- SEE BEAM GUARDRAIL {TYPE 31)
TRANSITION SECTION TYPE 21,
STANDARD PLAN C-25.20

NOTE
FOR GUARDRAIL DETAILS NOT SHOWN
- SEE BEAM GUARDRAIL {TYPE 31)
TRANSITION SECTION TYPE 20
STANDARD PLAN C-25.18

TOP OF RET~INI~~ '(ut~LL

NOTE

ATTACH GUARDRAIL TO CONCRETE


TRAFFIC BARRIER WITH 7/8" DIAM.
HIGH STRENGTH BOLTS {STANDARD
SPECIFICATION 9-06.5{4)) WITH
THIN SLAB FERRULE INSERTS
OR RESIN BONDED ANCHORS.
SEE THE CONTRACT PLANS.

TOP OF
SIDEWALK

3,

SIDEWALK@ RETAINING WALL AND CONTINUING BEYOND

SIDEWALK@ RETAINING WALL AND CONTINUING BEYOND

BEAM GUARDRAIL TRANSITION TYPE 20 CONNECTION

BEAM GUARDRAIL TRANSITION TYPE 21 CONNECTION

REINFORCING STEEL BENDING DIAGRAM

to

--"-~- ~--~

'
Co

'
b

'

TRAFFIC BARRIER DETAILS


FOR REINFORCED CONCRETE
RETAINING WALLS
STANDARD PLAN D-15.30-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

CONSTRUCTION JOINT - LEVEL TRANSVERSE WITH


ROUGHENED SURFACE

ALL DIMENSIONS ARE OUT TO OUT


SEE STD. SPEC. FOR BENDING DIAMETERS

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

NOTES

I
DATE LOCATION- SEE DETAIL

_j

I
_,

DATE LOCATION -SEE DETAIL

11

11

1. All numerals are approx. 3 1/4 wide except numeral 1


which is approx. 5/8 wide.

II

11

_j

_,

11

2. Spacing between the numeral 1 and any other numeral


is 1 Spacing between all other numerals is 3/4
II

11

11

3. Traffic Barrier Connections between the bridge and the


approaching roadway vary and may consist of concrete
barrier extensions. Install the Date Numerals on the
traffic barrier of the bridge itself.

_,
DATE LOCATION- SEE DETAIL

\_

\_

BRIDGE TRAFFIC BARRIER (TYP.)

BRIDGE TRAFFIC BARRIER (TYP.)

PLAN VIEW

PLAN VIEW

DATE LOCATION ON TWO-WAY BRIDGES

DATE LOCATION ON ONE-WAY BRIDGES

,t~ \

DATE NUMERA
-SEE DETA

~: MAY VAR'1

_s-

I
I
I
I

BRIDGE TRAFFIC BARRIER

~~&

BRIDGE END - SEE NOTE 3

,-,-----,
0~

OJ)

'

COl

ALIGN THE NUMERALS PARALLEL


TO TOP OF TRAFFIC BARRIER

5/8"

::: 3 1/4"

TOP OF
ROADWAY

1/8" (TYP.)

ELEVATION VIEW

DATE LOCATION DETAIL


~

c.:

c.:

~
......

"""
II

"""
II

TYPICAL DATE NUMERALS

NUMERAL "1"
TYPICAL SECTION VIEW

DATE NUMERAL
PLACEMENT ON
BRIDGE TRAFFIC BARRIER
STANDARD PLAN E-1

DATE NUMERAL DETAILS

SHEET 1 OF 1 SHEET

PERSPECTIVE VIEW

APPROVED FOR PUBLICATION

......
VI

Ken L. Smith
STATE DESIGN ENGINEER

02-21-07
DATE

Washington State Department of Transportation

~x15 Solid bridging over


o I I cops ond mid pone I point~~

ClJI
(!J,
LlD
I:
+- X

I~

C1J Ill

Q)
/ u
Q)
:J OJ D_

II
II
II
II

I
i-J

II

II
II

II

II

t4"x22" Drift bolts

lc

ITYPI~

lc

Spons 15'

~x15

Blackout

Solid bridging
I TYP I t

n~~'

--n'n-'j

0
G!l

II
II

II

I~

II

II

X
N

II

II

11

II

II

11

0
Q)lfl
C1J

u
C1J

:JD_

OJ

..

II
II
II
II
II
II

11
I

Q),
LlD
I: N
+- X

II

I!'I"

g 11

II

11

11

((

')')

XLL

'Drift bolts

,n

--mr-

mr---------' ' I

II

Ill
+-

Q)
+- D
0

~x12

Blackout ITYP
2x5 Outside stri nger to
outs1de str1nger, fosten
eoch stringer with
1s"x5" I og screw

U1

II

II

II

II

II
II
11-r

11

...
u
I

II
u

111
L
Q)
1::111
U1 C1J

0 u
"0

Ul -

-- E
0
0

n
I

~x12 S1S
plonk deck

Q)D

:r:I::r:
Ill
Q)
C1J
CD
Ll!lClJ

'

C1.J C1.J

D~

0 0
Q) 5

_c >,

111
+111

Ill

0
o_

_L-:3:0

5-Q_

+-

Q)

+-

Q)

CD 0 U
Q)- 0 0
_o ([) 4--- L

N
X
N

+D
ClJ:JL

_({)

o+E 0

:r:

I:D
+-C
-

C1J

"

-QQ)>,
+D_ 0

I:
+-u
_o

111

"([)
Q) ~ ::::
LON
+-N

m+0

C1J

i+':

D,

QlcnQJO
-UL~

- Q) C1J

o_ Q) +- c::
u +- 0
cxo_c

OOQJ
N+-E
0
UlLL
DQJ+Q)D_
Q)
uc
XN 0
Q)
DC
:r:QJO
L
QJQJD
L +- Q)
Q) +- u
1::00
O<DQ_

lflQ)
+-DQJ
c D
Q)D-0(])I: 0
-1111::
+Ill
111111
C1J +- 01
LI11C
+- 0 o_u
C1J
0
EC!JL
ODD
L+-Ill~

+-0
C:JO<
DOlfl

OQ)D+-

II
~

Spons 15
or 11
'
11
spon shown

DECK FRAMING PLAN

lflD
Q)(!JQ)
D-++-

II

See
Note 7

Ill

1 Bridge Po i I

:r:
I

Service Level

Deck

S1S
Plonk deck

'
I

hTr

II

II

II

ITYPI

Jl1

II

~I

DIA x1 1/ 2 " Bolt with


squore wosher

~x12

SINGLE LANE

II

~"

%"

ACP overlay lsee

~15x3'-o'' Sp I ices

spon shown

II

II

II

--u-

I~

II
or

-~
I

mr---

A~

1ces

~
~

I~

II

DECK FRAMING PLAN


~x12

o" sp
,n

II
II
II
II

..

II
~

I I

II

lc

II

II~

nJ

15 X 3'

2x5 Outside strin g er t 0


outside str i nger; fosten
eoch stringer with
1s"x5" I og screw

TWO LANE

HALF SECTION-PILE BENT

HALF SECTION-FRAME BENT

TYPICAL SECTION-TWO LANE BRIDGE

12'- o"
TS 3"x5"x1/~"
Stee I post
on

ft
--r-J-_
I I

I I

rod
ockwosher

ACP overlay lsee Note


~x12 515 Plonk deck

3fs" DIA x1'


Bolt with 1%"
squore wosher

I I
I I

Thrie beom

'x1/2" Bear i ng plote

1
/ 2"

I I

plote

D!Ax5" ---"""'..-...""'
Log bolts

On pile trestles, when H


exceeds 1 0' but is I ess thon
20' I ong i tud i no I broces sho I I be
pI oced on outside pi I es on both sides of
trestle i n every th i rd ponel or os requ i red by locol
conditions. When H exceeds 20'two-story bracing shol I
be used. Long i tud i nal struts ond cross broces sholl be
fastened ot eoch end with%" DIA bolts ond molleoble washers.

ELEVATION

~i.~======~Distr i bution
If)

See Note 7

+-

DD
I I
I I

UC!JC

:r:D

+111+-

Q) Q)

(f) -

L _o

C1.J

Ill

+-

-0

C1J

1::3::-

E 0
I:"
+-If)

'ii;

1111::

>,

([)I

QJUlCE

J'l(!J(!J

:3:

Ul Q)

c::

FRAME TRESTLE

:r:

o_

If)

Q)

+-D QJ

c::
Ll
Q)L)-0-

oO

QJ+- 01
L (f1 c::
+- 0 -

~u

(])

If)

Q_()

4-

<>.

If)

If)

C1J

C1J

o~N~

QJJ:: 0
(f]J::

E QJ L
ODD
L -

C1J :J
"
-OLen

CUJ::::

D c::
QJ 0
L
QJ QJD
L+- C1J
QJ+- ()
I: 0 0
O<Ll-

+-

+-+-0

On frome trest I es, I ong i tud i no I


bracing shol I be ploced on outside
posts on both sides of trestle i n
olternote ponels or os requ i red by locol
conditions
When H exceeds 2 0' , two- story
bracing sholl be ploced.
Long i tudinal struts ond
cross broces sho I I be fastened ot eoch end w i th 1/' DIA
bo Its ond mo I I eob I e washers,

XN
C1J

Q_

C!J4o_

<11::

+-({)0>,

<>.

L- 0

Q_

C1J

mClJ

QJU+-_Cl

SxS

Q)

:'::D
0

-l::lfl
Q) -

- D_
+-

F i I I er

If)

0
0

(),

0~

0
o_

Ill
Q)

(f)

0 - _o

+c

4-

D
Q)
QJ

C1J
_If)
J'l(!J
0 ()
C1J 0
_L
J'l

X+- 0 o
QJ+-LU
0 +- C1J

PILE TRESTLE

+-

C1J
Ll

C1J C1J
C1J L

I I
I I

Ill

::r

ELEVATION

plote

c::

1/'x12" Dowels

(f)

+-

;>,
0

"

:J
OlD

IEXPIRES

JANUARY 17. 19991

PILE OR FRAME
DETOUR BRIDGE WITH
ASPHALT OVERLAY
USE ONLY FOR TEMPORARY BRIDGES

STANDARD PLAN E-2


SHEET 1 OF 2 SHEETS

HALF SECTION-PILE BENT

HALF SECTION-FRAME BENT

TYPICAL SECTION-SINGLE LANE BRIDGE

APPROVED FOR PUBLICATION

Brian Ziegler

---------~~------

STATE DESIGN ENGINEER

05-29-98
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

3"x5"x 1/ 4"

Steel

post

NOTES

Beam Guardra i I Type 10


IThr i e Beam!

ITYPI

DIA bolt

1.

Dimensions and notations for superstructure are typ i cal

2,

A I I t i mber and

lane and two

3,

A I I p i I i ng sha I I be untreated Doug I as fir and sha I I be driven to deve I op a mini mum
capacity of 15 tons.

4,

Blocking for frame bents shal I be proport i oned to carry a minimum


hardware shall

5.

All

5.

Each deck

7.

On 17'spans, str i ngers shall be 5x15 51E.


On 15' spans, str i ngers shall be 5x15 51E.
Two- I one bridges sha I I use thirteen I i nes of stringers, one- I one bridges sha I I use seven

S.

Overlay thickness must be sufficient to cover bolts.

plank

be black,

15'- s" Span,

use

2 11

4' -211

1s'- o" Span,

use 3'-9"

3' -9"

Lj

I_

shall

ungalvan i zed.

be na i led to each str i nger w i th two 7" spikes,

number 1 or

larger.
I i nes of str i ngers.

1'-o"

1%" DIA Hole


ltwo places!

IL

Post

I oad bearing

load of 15 tons per post.

4x15x3' -o"
Str i nger spl i ce

Bolts w i th
ma I I eab I e
washers ITYPI

lane bridges.

I umber sha I I be # 2 or better and untreated Doug I as fir- I arch,

overlay
lsee Note 81

IL

for both single

Dr i I I and tap
DIA hole
10 UNC through

t4"

ost

115'

SECTION A-A

DI A Ho I e

ltwo places)

13/s" DIA Hole


I two places)------Dr i I I and tap
%" DI A hoI e
15 UNC through--------1

%" Stee I pI ate

1'

Post

DIA x7 1/ 2 "
AASHTO M 154

1/'

ct
Bearing
DIA hole

plate with
TS 3"x5"x 1/ 4 "

Steel

DISTRIBUTION PLATE DETAIL

plate

BASE PLATE DETAIL

bolt

1 1/ 4 " DIA xB" Rod


with I ockwasher
threaded 2
I TYP I

Stee I post

~~~

~@~~ti

8l5~i~

Base plate
1/ 'x5" Lag bolt
2

~~iS-~~

ITYPI

o::~~==:z~
11"' ~

uq;;

''H~''I/'

TYP
Distribution plate

~~iii~~

hlrU
-..~ ~ l!j cq:-,:

r-1------------- 4 x "varies", treated timber


paving bulkhead !fasten to
timber deck with%" DIA
lag bolts at 2'-o" centers!
Q)

+-

Deck pI ate sha I I be


beveled as required at
face of distribution plate

D_
CL

[)
Q)

W'

-~-

-01

)-

4-

%" Stee I deck pI ate

-0-

Steel

plate

+ +
+ +
+

1 1/ 4"

DIA Hole ITYPI

~11~~~

~~!!:~~
Cllo~~>>;~~~~

-----i c-

""

~i!'o:~..:

~~h~
0

-----i c-

""
-----i c-

11/4" DIA

<li(!i~l!'~

IEXPIRES

JANUARY 17, 1999 I

~~ttl~~

!1

~~~~

PILE OR FRAME
DETOUR BRIDGE WITH
ASPHALT OVERLAY
USE ONLY FOR TEMPORARY BRIDGES

ITYPI

BACKING PLATE DETAIL

STANDARD PLAN E-2


SHEET 2 OF 2 SHEETS

APPROVED FOR PUBLICATION

Brian Ziegler
STATE DESIGN ENGINEER

SECTION B-B

05-29-98
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

PILE
TYPE

PERIMETER

UNIT
WEIGHT

AREA

MOMENT OF
INERTIA

RADIUS OF
GYRATION

(in.)

(in.)

(lbs./ft.)

(in. 2 )

(in. 4 )

(in.)

MINIMUM

MAXIMUM

12

48.0

158

144

1728

3.5

14

56.0

215

196

3201

4.0

10

16

64.0

281

256

5461

4.6

13

14

46.4

178

162

2103

3.6

16 112

54.7

247

226

4057

4.2

11

SQUARE

18

59.6

295

268

5746

4.6

13

66.3

364

331

8758

5.1

16

24

79.5

524

477

18161

6.2

13

22

(.)

::::;

c..

en

Cl
....1

5"@ 1" PITCH

::c
....1 ~
~ c:::
c::: ~

en

=It b

Cl
....1

=It b

::::;

c..

....

....'

Co
0::

I-

(!)

w
....1

LL.
I

co

0
(5
w
0::

....1

i=

(..)

::::>
Cl

(..)

::::i
D..

en

Cl

....1

0::

D..

::5

"C

ll'i

(..)

Cl

::::>

M' 0

::::i

w 0::
0 en
en
~ w

D..

en

en
en

....1

....1

c:::
en

I~

....1

0::

@)

D..

en

I-

c:::

c:::

1" R
(TYP.}

::5

(..)

I-

PRESTRESSING
STRANDS (TYP.)
EQUALLY SPACED

::c

(..)

D/2

....1

::c

5. 2 1/2" cover if pile is exposed to salt water.

w
~ ::c

Cl

w
~ ::c
I-

c:::
en

0::

1 1/2" MIN. COVER


SEE NOTE 7

- -

()

en

::c

(5

0::

w
w
....1

0::

G
::::>

(..)

ITJ

I-

c:::

....1

Co

D..
en @)
.... en

BENDING DIAGRAM

0::

OCTAGONAL

z'

TYPICAL SECTIONS

5" @ 1" PITCH

PILES LESS THAN


35' LONG

MAY BE FIELD BENT (TYP.)


5" @ 1" PITCH

PILES MORE THAN


35' LONG

SPI~~ ~~ l,,~,,

SPIRAL REINFORCEMENT

SHOP WELD
DEFORMED BAR

PLAIN STEEL BAR

AASHTO M 31 GR. 60 AASHTO M 31 GR. 60

1/2" DIAM., 270 ksi


STRAND LIFTING
LOOP

=It ~

Cl

4. Strength of concrete shall be 5.0 ksi at release and 7.0 ksi at final.

SQUARE

~ w

(..)

I- w
....1

LL.

....1

LL.

1. Place lifting loops at the lifting points shown in the PILE HANDLING DIAGRAM, Standard
Plan E-4a, for the case stated in the contract.

Ci
M' 0
w 0::
w

i=

!f
Cl

SPIRAL TERMINATION
DETAIL

3. All prestressing strands are 1/2" or 0.6" diameter (dps> Grade 270, uncoated strands,
AASHTO M203, jack to 0.75 Fpu maximum.

co

"C

....1
....1

::::>

SPIRAL REINF.
(TYP.)

2. Spirals shall be spliced either by lapping one full turn and bending the end of the spiral to
a 135 seismic hook, by welding, or by the use of a mechanical connector that develops
125% of the minimum yield strenth of the spiral. Welding shall meet the requirements of
Standard Specification 6-02.3(24)E.

"'c.

0::

"'c.

PRESTRESSING
STRANDS (TYP.)
EQUALLY SPACED

3 WRAPS OF SPIRAL
WITH WELDED LAP
SPLICE AT END

NOTES

1" CHAMFER (TYP.)

....'

1/2" DEEP 6" LONG 2" WIDE


RECESS, CENTERED ABOUT
LIFTING LOOP

PILE DETAILS

Co
0::

0
(5
w

OPTIONAL 114" )( 2 112" )( D (O.D.)


STEEL DRIVING RING
(EITHER END OR BOTH)

....

::c

SEE SPIRAL
TERMINATION
DETAIL (TYP.)

....1

1" CHAMFER
ALL AROUND
(TYP.}

ELEVATION

en ()

(.)

TYP.

5"@ 1" PITCH

::c
~
~ c:::
c::: ~
en ()

PRESTRESSING
STRAND

NOTE 1
1 1/2" CLR.

20

OCTAGONAL

NOTE 1

NUMBER OF STRANDS

COLD DRAWN WIRE

DEFORMED WIRE

AASHTO M32

AASHTO M225

WELD DIMENSIONS
E

LENGTH (L)

#4

1/2" DIAM.

W20

D 20

4"

#5

5/8" DIAM.

W31

D 31

6"

S(E~(

U2 OR S(E)

r
C

PRECAST PRESTRESSED
CONCRETE PILES
STANDARD PLAN E-4
L

<~~6~ ~tg

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

OR

SPIRAL WELDED LAP SPLICE DETAIL

....

Harold J. Peterfeso

SEE TABLE FOR WELD DIMENSIONS

SPIRAL LAP SPLICE DETAIL

STATE DESIGN ENGINEER

fJ'I Washington

08-27-03
DATE

State Department of Transportation

#4 SPIRAL@
3" PITCH (TYP.)

PILE CAP

4 # 6 (MIN.) GROUTED INTO


DRILLED OR FORMED HOLES

PILE CAP

4 # 6 (MIN.) GROUTED INTO


DRILLED OR FORMED HOLES

PILE CAP

PRECAST PILES, HANDLING NOTES


1. For pile lifting Cases 1 and 2, do not allow pile tip to bear on other
piling stored in a lower layer.
2. For pile lifting Cases 3 and 4, tilt the pile in the air, do not allow the
pile to touch the ground.

STRAND (TYP.)

3. The minimum angle between the pile and the lifting strap is 60
when the pile is in the horizontal position.
4. When directed to remove a lifting loop, cut it off at the bottom of the
recess and patch the recess by filling it with 1:2 mortar, finishing it
to the level of the pile face. The patch shall be allowed to cure at
least 24 hours prior to driving the pile.
I

5. The length of the formed or drilled hole shall allow for potential cutoff and full development length of the steel reinforcement. The
holes must be roughened and filled with epoxy resin.

PRECAST
PILE

PRECAST
PILE

#4 SPIRAL@
3" PITCH (TYP.)

#4 SPIRAL@
3" PITCH (TYP.)

CAST IN PLACE
CLASS 4000P
CONCRETE

6. Expose the spiral reinforcement at the pile head and splice with new
spiral in accordance with Standard Plan E-4, Note 2.

SEE
NOTE 5

7. For handling and bunking, the Prestressed piles shall have at least
the minimum number of strands shown on Std Plan E4.

ROUGHENED
SURFACE

8. Piles stored on the ground should be bunked on level dunnage at


no more than 20' on center, with a maximum overhang of 10'.

PRECAST
PILE

PILE CUTOFF WITH STRANDS


EXTENDING LESS THAN 2' - 0"

PILE CUTOFF WITH STRANDS


EXTENDING 2' - 0" MINIMUM

SEE
NOTE 5

BUILD-UP ON PILE
DRIVEN BELOW CUTOFF

PILE TO PILE-CAP CONNECTIONS

L
L/8 I

L/4

L/4

L/4

L/8

SEE
NOTE 3

LIFTING POINT (TYP.)


PILE

\_ ROCKER BUNKS

_j

"L" IS MORE THAN 90'

L
L/6

L/3

L/3

I L/6

SEE NOTE 1

SEE NOTE 1

WHEN "L" IS 50' OR LESS

WHEN "L" IS MORE THAN 50' BUT NOT MORE THAN 70'

CASE 1

CASE2

PILE
1=1

\__BUNK

ROCKER BUNK __/

SEE
NOTE 3

"L" IS MORE THAN 70'


BUT NOT MORE THAN 90'

L/10

L
L/5

3L/5

L/5
~

L/10

PRECAST PRESTRESSED
CONCRETE PILES
HANDLING AND CAPPING
STANDARD PLAN E-4a
SHEET 1 OF 1 SHEET

PILE
BUNK__/

\__BUNK

"L" IS 70' OR LESS

PILE BUNKING AND SHIPPING SUPPORT DIAGRAMS

SEE NOTE 2

SEE NOTE 2

WHEN "L" IS MORE THAN 70' BUT NOT MORE THAN 90'

WHEN "L" IS MORE THAN 90'

CASE3

CASE4

PILE HANDLING DIAGRAMS

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

fJ'I Washington

08-27-03
DATE

State Department of Transportation

VARIES 12" TO 24"

FACE OF CURB

FACE OF CURB

FACE OF CURB

VARIES
10" TO 22"

FACE OF CURB

6 1/2"

6 1/2"

5 1/2"

(SEE CONTRACn

~c/7 ~6~~ ROA::y

MATCH ROADWAY
SLOPE

1/2" R.

2L ___}_ "

ROADWAY
I>

'

(oi~t>
t> '~i>
' I>~'[>

1/2" R.

1/2" R.

~J

---,
-'bl>
.JI>

i>t> '

11 1/2"

111/2"

DUAL-FACED CEMENT CONCRETE


TRAFFIC CURB AND GUTTER

CEMENT CONCRETE
TRAFFIC CURB AND GUTTER

DEPRESSED CURB SECTION


AT CURB RAMPS AND
DRIVEWAY ENTRANCES

6"

1/2" R.

'

.'

1"R.

~, ~r

'

CEMENT CONCRETE OR
ASPHALT CONCRETE
SIDEWALK OR PATH

CEMENT CONCRETE
CURB RAMP, LANDING,
OR DRIVEWAY
ENTRANCE

I>

I>'

'

NOTE

1. See Standard Plan F-30.1 0 for Curb Expansion and


Contraction Joint spacing.

'

t>

3/8" PREMOLDED JOINT FILLER


(WHEN ADJACENT TO CEMENT
CONCRETE SIDEWALK)

3/8" PREMOLDED
JOINT FILLER

CEMENT CONCRETE PEDESTRIAN CURB

FLUSH WITH GUTTER PAN AT CURB


RAMP ENTRANCE - 1/2" VERTICAL LIP
AT DRIVEWAY ENTRANCE

CEMENT CONCRETE PEDESTRIAN CURB


AT CURB RAMPS, LANDINGS,
AND DRIVEWAY ENTRANCES

.J
.J

LlJ
Cl
Cl

::J

0::
LlJ
LL.

FACE OF CURB

FACE OF CURB

VARIES 12" TO 24"

FACE OF CURB
FACE OF CURB

VARIES
10" TO 22"

1" R.

Cl

1/2" R.
ROADWAY

ROADWAY

ROADWAY

ROADWAY

CEMENT CONCRETE CURBS


STANDARD PLAN F-10.12-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

DUAL-FACED CEMENT
CONCRETE TRAFFIC CURB

CEMENT CONCRETE
TRAFFIC CURB

MOUNTABLE CEMENT
CONCRETE TRAFFIC CURB

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

=13'- 0 1/4"
= 5'- 0 3/4"

= 5'- 0 3/4"

3/8" PREMOLDED JOINT FILLER

5'- 0" R.
CEMENT CONCRETE
CURB AND GUTTER

5'- 0" R.

5'- 0" R.

RECTANGULAR FRAME AND GRATE- NOT


INCLUDED IN CURB AND GUTTER BID ITEM

GUTTER PAN

PLAN VIEW

~CURB

2. The centerline of the drainage structure may differ from the


centerline of the frame and grate.

c- & GRATE- SEE NOTE 2

VARIES

2- 10 1/2"

6 1/2"
1"

1'-6"- 2'-10 1/2"

6 1/2"

13"

5 1/2"

1. The intent of this design is to facilitate the compaction of Hot


Mix Asphalt pavement adjacent to a drainage structure.

CATCH BASIN GUTTER PAN

CENTERLINE OF FRAME

FACE OF

NOTES

(1.08')

SLOPE THE GUTTER PAN DOWN TO


THE RECTANGULAR FRAME

1/2" R.

ry
rJ
FACE OF CURB

5 1/2"

PE

I>

TOP OF
ROADWAY

I>'

I>~

......

......

I>

'
I>

I>

I>

I>

TOP OF
ROADWAY

/
/
/
/
/
/
/
/

'

I>

'

I>

[>

'

I>

[>

'

1/2" R.

/
/

'

I>

/
/
/

1" R

'

MATCH

1" R.

1/2" R.

'

'
[>

~J

/
/
/
/
/
/
/
/
/
/

I>
I>

'

I>

'

I>

SECTION

ADJUSTMENT SECTION - NOT INCLUDED


IN CURB AND GUTTER BID ITEM

[>

'
~

DRAINAGE STRUCTURE - NOT INCLUDED


IN CURB AND GUTTER BID ITEM

I>

SECTION

- __ ,
/
/
/
/
/
/

CEMENT CONCRETE
CURB AND GUTTER PAN

I
I
I
I
I
I
I

STANDARD PLAN F-1 0.16-00


SHEET 1 OF 1 SHEET

l~c;>METFi~ VIEW

/
/
/
/
/
/
/

l'-'-'-'-'-'-'-

/
/
/
/
/
/

'-

"'-~//

APPROVED FOR PUBLICATION

....

Kevin J. Dayton
STATE DESIGN ENGINEER

12-20-06
DATE

fJ'I Washington State Department of Transportation

SIDEWALK
5'- 0" MIN.

BUFFER STRIP

CURB

03'- 0" MIN.

OUTSIDE

CURB

TRUCK APRON

0LANE

0siDEWALK
5'- 0" MIN.

LANE

SEE CONTRACT PLANS FOR TREATMENT (TYP.)


CENTRAL ISLAND

CURB 3
SIDEWALK 0
5'- 0" MIN.

BUFFER STRIP
3'- 0" MIN.

CURB

CIRCULATING ROADWAY 0

CURB

TRUCK APRON 0

2
SEE CONTRACT PLANS FOR
TREATMENT

CURB PLACEMENT

SEE CONTRACT PLANS FOR PAVING AND SURFACING (TYP.)

SECTION
(ROUNDABOUT CONFIGURATION WILL VARY
DEPENDING ON CONTRACT PLANS)

NOTES
1. See Standard Plan F-30.1 0 for Curb Expansion and
Contraction Joint spacing.

SPLITTER ISLAND
CURB RAMP (TYP.)
FACE OF
CURB

5..

0-

10"

12"

LEGEND

SIDEWALK (TYP.)

WIDTH VARIES- SEE CONTRACT PLANS

T'
FACE OF
CURB

f,

ROUNDABOUT
TRUCK APRON

BUFFER
SEE CONTRACT PLANS FOR
TREATMENT (TYP.)

CURB 3CENTRAL ISLAND

~~~~~~--~

1-

CURB 2 - OUTSIDE
OR RIGHT SIDE

1'-10"

ROUNDABOUT SPLITTER ISLAND


NOSING CURB

CURB1
ROUNDABOUT TRUCK APRON
CEMENT CONCRETE CURB & GUTTER

OUTSIDE
TRUCK APRON
SPLITTER ISLAND

SECTION C
DETAIL
(SEE CONTRACT PLANS FOR R)
3/8" PREMOLDED JOINT FILLER FACE OF

12" R.
1/2" R.
(TYP.)

MATCH

ROADWA~URB ~?

1/2" R.
(TYP.)

12" R.
4" R.

SIDEWALK

SLOPE~
TOP OF TRUCK
~
APRON =co_t

1_

ROUNDABOUT CEMENT
CONCRETE CURBS

'"

PARTIAL PLAN

4"R.

~~~----~~--~~~~~~--~~

15"

CURB2
(OUTSIDE, RIGHT SIDE OR SPLITTER ISLAND)
ROUNDABOUT CEMENT CONCRETE
CURB AND GUTTER

15"

CURB3
ROUNDABOUT CENTRAL ISLAND
CEMENT CONCRETE CURB

9"

STANDARD PLAN F-10.18-00

OPTIONAL
CONSTRUCTION
JOINT

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
fll

STATE DESIGN ENGINEER

06-27-11
DATE

Washington State Department of Transportation

TRAVELED WAY

USABLE SHOULDER

SLOPE ROUNDING

2'- 0" MIN.

FACE OF CURB

NOTES
1. The installation of curb in areas with existing guardrail
could require the removal and resetting of the guardrail
or its components.

1'- 0"

EXTRUDED CURB
TYPE 1, 2, 3, 4, 5 OR 6
(SEE CONTRACT FOR TYPE)
-SEE NOTE 4

2.

Extend shoulder pavement to provide a base for the


extruded curb.

3. See Contract for exception to distances shown.


4. Type 3 and 6 curbs are not used on roadways with a
posted speed greater than 40 mph.
5. Type 3 and 6 are not used under beam guardrail on
roadways with a posted speed greater than 50 mph .
....1
....1

LlJ

EXTRUDED CURB WITH SLOPE ROUNDING

0
0

TRAVELED WAY

::::i

USABLE SHOULDER

6.

For extruded curb placement at Beam Guardrail Type 31,


See Standard Plan C-20.1 0.

7.

For extruded curb details, See Standard Plan F-10.42.

1'- 0"
MIN.

0::
LlJ
LL.

FACE OF CURB
EXTRUDED CURB
TYPE 1, 2, 3, 4, 5 OR 6
(SEE CONTRACT FOR TYPE)
-SEE NOTE 4

TRAVELED WAY

USABLE SHOULDER

EMBANKMENT SLOPES
4H: 1V OR FLATTER

SEE NOTE 2

2'- 0" MIN.


SLOPE ROUNDING

FACE OF CURB

HINGE-POINT

EXTRUDED CURB WITHOUT SLOPE ROUNDING

2'- 0"

EXTRUDED CURB
TYPE 1, 2, 3, 4, 5 OR 6
(SEE CONTRACT FOR TYPE)
-SEE NOTE 4

------<_

HINGE-POINT

SEE CONTRACT FOR DRAINAGE


REQUIREMENTS
SEE NOTE 2
SEE STANDARD PLAN
TRAFFIC BARRIER SHOULDER WIDENING

EXTRUDED CURB AT CUT SLOPE


TRAVELED WAY

USABLE SHOULDER

FACE OF CURB SHALL NOT


EXCEED FACE OF GUARDRAIL
EXTRUDED CURB
TYPE 1, 2, 3, 4, 5 or 6
(SEE CONTRACT FOR TYPE)
-SEE NOTE 5

EXTRUDED CURB
PLACEMENT

HINGE-POINT
SLOPE ROUNDING NOT
REQUIRED BEHIND
TRAFFIC BARRIER

STANDARD PLAN F-10.40-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

EXTRUDED CURB AT BEAM GUARDRAIL TYPE 1

B"

B"

(/)

w
0::
w

1"

6"

1"

6"

1"

1"

ID
....1
....1

iii

L. .- _!_,_~_1>_.

~! ~I

_____. ._._-'
. _:-_,:_...._ ....JI

Cl

TYPE 1
(HOT MIX ASPHALT)

_ _ _ L _ _ __ _ _

#3 BAR

12

12"
~~~~------------~~~~10~~-~o~S(~~----------------~~

"

BE

TWEEN JOINTS (TYP.)

I
!

12"

12"

~I,I

TYPE4

,
I

(CEMENT CONCRETE)

CEMENT CONCRETE EXTRUDED CURB

B"

B"
1"

6"

1"

# 3 BARS (TYP.)

6"

1"

1"

SPACING OF ANCHOR BARS


(FOR TYPES 4, 5, AND 6)

)'

NOTE

~
?~

1" R. -

--~'<t

1>__ ,,
I
I
I
I
I

TYPE2
(HOT MIX ASPHALT)

JOINTS MAY BE FORMED DURING INSTALLATION USING


A RIGID DIVIDER OR SAWCUT AFTER CONCRETE CURES
TO MINIMUM STRENGTH.

_ _ _ L _ _ __ _ _

I
I
I
I
I

#3 BAR

TYPES
(CEMENT CONCRETE)

10"
2 1/2"

5"

10"
2 1/2"

2 1/2"

5"

2 1/2"

EXTRUDED CURB
STANDARD PLAN F-1 0.42-00
SHEET 1 OF 1 SHEET

TYPE3
(HOT MIX ASPHALT)

_ _ _ L _ _ __

#3 BAR

TYPES
(CEMENT CONCRETE)

APPROVED FOR PUBLICATION

....

Ken L. Smith
STATE DESIGN ENGINEER

fJ'I Washington

01-23-07
DATE

State Department of Transportation

(/)

w
w

0::
ID
....1
....1

iii

Cl

1" R.

#3 REBAR- REQUIRED ONLY IN TANGENT


BLOCK, WHEN LENGTH EXCEEDS 30"
(1 1/2" CLR. BOTH ENDS}

2" R.

TOP VIEW
2" R.

INSIDE CORNER BLOCK


2"

+I

5"

.....

I:

12"

ISOMETRIC VIEW

TANGENT BLOCK

TYPICAL OF ALL

END VIEW

TOP VIEW

OUTSIDE CORNER BLOCK

INSIDE CORNER BLOCK

18" RADIUS BLOCK

23"
\

30" R.

\
\
\

I
I

PRECAST CONCRETE
SLOPED MOUNTABLE CURB

45

I
I
I
I
I
I

OUTSIDE CORNER BLOCK

30" RADIUS BLOCK

STANDARD PLAN F-1 0.62-01


SHEET 1 OF 2 SHEETS

ISOMETRIC VIEWS
TOP VIEW

TOP VIEW

18" RADIUS BLOCK

30" RADIUS BLOCK

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

09-05-07
DATE

State Department of Transportation

(/)

w
w

0::
ID
....1
....1

1" R.

iii

ID

2" R.

2" R.

Cl

<(

<(

+I

5"

I:

12"

SECTION

TOP VIEW

TOP VIEW

INSIDE RADIUS BLOCK

OUTSIDE RADIUS BLOCK

CURB RADIUS TABLE


CURB

DIMENSION

DIMENSION

DIMENSION

RADIUS

3'

12"

2"

8"

4' TO 5'

12"

1 1/2"

9"

6'

12"

1"

10"

7'

12"

7/8"

10 1/4"

8'

18"

1 1/8"

15 3/4"

9'

18"

1"

16"

10'

18"

7/8"

16 1/4"

11' TO 13'

18"

3/4"

16 1/2"

14' TO 15'

18"

518"

16 3/4"

16' TO 17'

24"

3/4"

22 1/2"

18' TO 22'

24"

518"

22 3/4"

23' TO 29'

24"

1/2"

23"

30' TO 34'

30"

1/2"

29"

35' TO 48'

30"

3/8"

29 1/4"

49' TO 60'

30"

1/4"

29 1/2"

OVER 60'

USE TANGENT BLOCK, SEE SHEET 1

THIS TABLE LISTS THE CALCULATED DIMENSIONS FOR CASTING


BLOCKS SUITABLE FOR CONSTRUCTING VARIOUS CURB RADII.
CURVED BLOCKS, OR BLOCKS WITH DIFFERENT DIMENSIONS
MAY BE ACCEPTABLE WITH PRIOR APPROVAL OF THE ENGINEER.

INSIDE RADIUS BLOCK

PRECAST CONCRETE
SLOPED MOUNTABLE CURB
OUTSIDE RADIUS BLOCK

STANDARD PLAN F-1 0.62-01


SHEET 2 OF 2 SHEETS

ISOMETRIC VIEWS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

fJ'I Washington

09-05-07
DATE

State Department of Transportation

NOTE

en

----------------

w
w

a:
[I]

The dual faced curb may be constructed by using two


precast concrete sloped mountable curbs (longitundinal
halves) so long as the installation is consistent with the
dimensions shown in the plan.

....1
....1

iii

--------- --------

Cl

2"R.

_,..

L I"
~I

~ .:r::::: 1-----------""----------------------"~
=J1
1- -
~
~~.
~P.)
j_

1 1t2"

~~-

TOP
2'- 6" MIN.

"I

5'- 0" MAX.

I !

SIDE

DUAL SLOPED BLOCK

2" R.

24"

1 1t2"

~~

END

SIDE

(TYP.)

24 x 20 TAPER BLOCK

FRONT

20"

BACK

1'-11"

CLR.

TOP

~LI
~
~

2'- 6" MIN.


5'- 0" MAX.

b---~---------~~

TR.

SIDE
END

NOSING BLOCK
NOSING BLOCK

DUAL SLOPED BLOCK

SIDE
(TYP.)

20 x 16 TAPER BLOCK

FRONT

16"
16 x 12 TAPER BLOCK

BACK
20 x 16 TAPER BLOCK

24 x 20 TAPER BLOCK

ISOMETRIC VIEW
5'- 0"

2" R.

__!
L tr--~~--~~~-~~::.-;~~-.;~--;~-::.;~-::.;~-::.;::.-.::.;:...-~;:...-~;----.;~~;1

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

SIDE
FRONT

16 x 12 TAPER BLOCK

PRECAST CONCRETE
DUAL FACED
SLOPED MOUNTABLE CURB
STANDARD PLAN F-1 0.64-02

fll
BACK

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

SIDEWALK- 6' - 0" MIN.


FOR SIDE TREATMENT

SIDEWALK- 6' - 0" MIN.

SEE OTHER SIDEWALK SECTIONS

(SEE CONTRACT)

(SEE CONTRACT)

1/2" R. (TYP.)

6 1/2"
FACE OF CURB

1/2" R. (TYP.)
CURB NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12
~I>

~<?<:,~ .._-..1

..

"'

ROADWAY

~-<.;~~.

-<.~~

SEE RAISED EDGE


DETAIL- THIS SHEET

SEE CURB FACE DETAIL

WITH RAISED EDGE


2'- 0"
1'-

1'-0"

SIDEWALK - 6' - 0" MIN.


(SEE CONTRACT)

MIN.

ROUNDING

NOTE
CURB FACE DETAIL
CURB NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12

MONOLITHIC CEMENT CONCRETE


CURB AND SIDEWALK

/.0.. FINISHED GRADE 1" BELOW


'V" TOP OF CONCRETE SURFACE

1. Four feet of the sidewalk width shall be the minimum pedestrian accessible
route free of vertical and horizontal obstructions. Gratings, Access Covers,
Junction Boxes, Cable Vaults, Pull Boxes and other appurtenances within the
sidewalk must have slip resistant surfaces, be flush with surface, and match
grade of the sidewalk.

EXTEND SIDEWALK TRANSVERSE EXPANSION


JOINTS TO INCLUDE CURB (FULL DEPTH)

WALL OR BARRIER

ADJACENT TO CURB

SIDEWALK

(STEEP FILL SLOPES)

BROOMED FINISH (TYP.)


4" WIDE, SMOOTH
TROWELED PERIMETER

SIDEWALK- 6' - 0" MIN.


(SEE CONTRACT)

CEMENT CONCRETE CURB


(CURB AND GUTTER SHOWN)
NOT INCLUDED IN BID ITEM
SEE STANDARD PLAN F-10.12

I>

CURB NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12

3/8" PREMOLDED
JOINT FILLER

3/8" PREMOLDED
JOINT FILLER

SIDEWALK ADJACENT TO WALL DETAIL


ADJACENT TO CURB
BRIDGE OR PEDESTRIAN
RAILING

BARRIER - SEE
CONTRACT PLANS ~
I
I
I
I

SIDEWALK- 6' - 0" MIN.


(SEE CONTRACT)
1/2" R. (TYP.)
CURB NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12

ISOMETRIC VIEW
VERTICAL WALL SEE DETAIL

I>

ADJACENT TO CURB AND RAILING OR WALL

FOR SIDE TREATMENT

SIDEWALK- 5'- 0" MIN.

3'- 0" MIN.


BUFFER STRIP

SEE OTHER SIDEWALK


SECTIONS

(SEE CONTRACT)

(SEE CONTRACT)

JOINT AND FINISH


DETAIL

RAISED EDGE DETAIL


EXTEND SIDEWALK TRANSVERSE
JOINTS TO INCLUDE RAISED EDGE

CEMENT CONCRETE
SIDEWALK

CURB NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12

STANDARD PLAN F-30.10-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

FINISHED GRADE 1" BELOW TOP OF CONCRETE


SURFACE FOR PLANTING- FLUSH IF PAVED

Pasco Bakotich Ill

PREMOLD ED
JOINT FILLER

ADJACENT TO BUFFER STRIP

......

------~S~T~M~E~DE~SI~GN~E~NG~IN~E~ER~----

EXPANSION JOINT

CONTRACTION JOINT

6120113
DATE

. . . Washington State Department of Transportation

4'- 0" MIN.SEE CONTRACT PLANS

3/8" EXPANSION JOINT (TYP.)SEE STANDARD PLAN F-30.10

4'- 0" MIN.SEE CONTRACT PLANS


PEDESTRIAN CURB SEE NOTE 9

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

2. Where "GRADE BREAK'' is called out, the entire length of the grade
break between the two adjacent surface planes shall be flush.
SIDEWALK

CURB AND GUTTER

CURB & GUTTER


CURB RAMP

CURB RAMP

CURB RAMP

4'- 0" MIN. (TYP.) -

DETECTABLE WARNING SURFACESEE STANDARD PLAN F-45.10

FACE OF CURB

3. Do not place Gratings, Junction Boxes, Access Covers, or other appurtenances in front of the Curb Ramp or on any part of the Curb Ramp or
Landing.

SIDEWALK

4'- 0" MIN. (TYP.) SEE CONTRACT PLANS

....1
....1

<t

, - - - - --->;--,

SEE CONTRACT PLANS

CROSSWALK

CROSSWALK

0
0

w
u.

PLAN VIEW

TYPE PARALLEL A

TYPE PARALLEL B

4'-0" MIN.
SEE CONTRACT PLANS

5. See Standard Plan F-30.1 0 for Cement Concrete Sidewalk Details.


6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include
the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian
Curb, or Sidewalks.
7. The Curb Ramp maximum running slope shall not require the ramp length
to exceed 15 feet to avoid chasing the slope indefinitely when connecting
to steep grades. When applying the 15-foot max. length, the running slope
of the curb ramp shall be as flat as feasible.

PLAN VIEW

DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-45.10

4. See Contract Plans for the curb design specified. See Standard Plan
F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and
Pedestrian Curb details.
See Contract Plans for width and placement of sidewalk.

DEPRESSED CURB & GUTTER

FACE OF CURB

DEPRESSED CURB & GUTTER

DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-45.10

::::i
0::

1. Provide a separate Curb Ramp for each marked or unmarked crosswalk.


Curb Ramp location shall be placed within the width of the associated
crosswalk, or as shown in the Contract Plans.

8. Curb Ramp, Landing, and Flares shall receive broom finish. See Standard
Specifications 8-14.

GRADE BREAK

- a:

"OJT7Tl<T7770....-n

CEMENT CONCRETE PEDESTRIAN


CURB - SEE NOTE 9

_l_ "r

coUNTER SLOPE

5 o%MM

2.0% MAX.

LANDING

SECTION

DEPRESSED CURB & GUTTER SEE STANDARD PLAN F-10.12


AND NOTE 6
15'- 0" MAX.
SEE NOTE 7
SIDEWALK

15'- 0" MAX.

4'-0" MIN.

15'- 0" MAX.

SEE NOTE 7

SEE CONTRACT PLANS

SEE NOTE 7

...
.

:,.

.- 8.3%MI>:f....

2.0% MAX .

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

SECTION

- -

GRADE BREAK

CURB RAMP

SLOPE IN EITHER DIRECTION

PEDESTRIAN CURB SEE NOTE 9

....

CURB RAMP

CURB RAMP

LEGEND

...

GRADE BREAK

GRADE BREAK

9. Pedestrian Curb may be omitted if the ground surface at the back of the
Curb Ramp and/or Landing will be at the same elevation as the Curb
Ramp or Landing and there will be no material to retain.

TOP OF
ROADWAY

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

SECTION

0
"CEMENT CONCRETE CURB RAMP TYPE
PARALLEL B" PAY LIMIT- SEE NOTE 6

"CEMENT CONCRETE CURB RAMP TYPE


PARALLEL A" PAY LIMIT- SEE NOTE 6

PARALLEL CURB RAMP


STANDARD PLAN F-40.12-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
fll

---~S~~~TE~D~ES~IG~N~EN=GI~NE=ER~---

TYPE PARALLEL A PAY LIMIT

ISOMETRIC VIEW
TYPE PARALLEL B PAY LIMIT

6120113
DATE

Washington State Department of Transportation

NOTES
1.

4' - 0" MIN. - SEE


CONTRACT PLANS

CEMENT CONCRETE
PEDESTRIAN CURB SEE NOTE 9

CEMENT CONCRETE
PEDESTRIAN CURB
- SEE NOTE 9

CURB RAMP
CURB RAMP

MATCH SIDEWALK (4'- 0" MIN.) SEE CONTRACT PLANS

Provide a separate Curb Ramp for each marked or unmarked crosswalk. Curb Ramp
location shall be placed within the width of the associated crosswalk or as shown in the
Contract Plans.

2. Where "GRADE BREAK" is called out, the entire length of the grade break between the two
adjacent surface planes shall be flush.

DETECTABLE WARNING SURFACESEE STANDARD PLAN F-45.10


3" R.
(TYP.)

3.

Do not place Gratings, Junction Boxes, Access Covers, or other appurtenances in front of
the Curb Ramp or on any part of the Curb Ramp or Landing.

4. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb,
Curb and Gutter, Depressed Curb, Gutter and Pedestrian Curb details.
3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

CEMENT CONCRETE
PEDESTRIAN CURB SEE NOTE 9

DETECTABLE WARNING SURFACESEE STANDARD PLAN F-45.10

See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans
for width and placement of sidewalk.

6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include the adjacent Curb,

BUFFER STRIP (TYP.) SEE CONTRACT PLANS

CEMENT CONCRETE
CURB & GUTTER SEE NOTES 4 & 6

5.

DEPRESSED CURB AND


GUTTER - SEE NOTES 4 & 6

Curb and Gutter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks.

CEMENT CONCRETE CURB


AND GUTTER - SEE NOTES 4 & 6

DETAIL

DEPRESSED CURB & GUTTER SEE NOTES 4 & 6

7. The Curb Ramp maximum running slope shall not require the ramp length to exceed 15 feet

to avoid chasing the slope indefinitely when connecting to steep grades. When applying the
15-foot max. length, the running slope of the Curb Ramp shall be as flat as feasible.

CURB RADIUS DETAIL

8.

Curb Ramp, Landing and Flares shall receive broom finish. See Standard Specifications 8-14.

9.

Pedestrian Curb may be omitted if the ground surface at the back of the Curb Ramp and/or
Landing will be at the same elevation as the Curb Ramp or Landing and there will not be
material to retain.

PLAN VIEW

TYPE COMBINATION
WITH BUFFER

LEGEND
-

15'- 0" MAX.


SEE NOTE 7

4'- 0" MIN.


CEMENT CONCRETE
PEDESTRIAN CURB SEE NOTE 9

SEE CONTRACT PLANS

GRADE BREAK

coUNTER SLOPE

LANDING

CURB RAMP

SECTION

SLOPE IN EITHER DIRECTION

DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-45.10

15'- 0" MAX.


SEE NOTE 7

GRADE
BREAK

2.0% MAX.

TOP OF
ROADWAY

DEPRESSED CURB AND GUTTER SEE STANDARD PLAN F-10.12 AND NOTE 6

4'- 0" MIN.


SEE CONTRACT PLANS

GRADE BREAK

GRADE BREAK
8.3% MAX.

2.0% MAX.

CURB RAMP

LANDING

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

15'- 0" MAX.


SEE NOTE 7

SECTION

8.3%

MAX-

CURB RAMP

"CEMENT CONCRETE CURB RAMP TYPE


COMBINATION" PAY LIMIT- SEE NOTE 6
CURB RAMP

4'- 0" MIN.


SEE CONTRACT PLANS

3' - 0" MIN. - SEE


CONTRACT PLANS
TOP OF
ROADWAY

2.0% MAX.
,.

CEMENT CONCRETE PEDESTRIAN


CURB (TYP.) - SEE NOTE 9

COMBINATION CURB RAMP

t>.,.

SECTION

STANDARD PLAN F-40.14-02

SHEET 1 OF 1 SHEET

CEMENT CONCRETE CURB AND


GUTTER - SEE NOTES 4 & 6

APPROVED FOR PUBLICATION


ISOMETRIC VIEW

TYPE COMBINATION
PAY LIMIT

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

....1
....1

::::i

CURB RAMP WIDTH 4' - 0" MIN.

0::

u.

SEE CONTRACT PLANS 4'- 0" MIN.

CEMENT CONCRETE
SIDEWALK- SEE NOTE 5

2. Where "GRADE BREAK" is called out, the entire length of the grade
break between the two adjacent surface planes shall be flush.

GRADE BREAK

SEE CONTRACT PLANS CURB RAMP


4' - 0" MIN.
CEMENT CONCRETE SIDEWALKSEE NOTE 5
PROVIDE SMOOTH
TRANSITION TO
SIDEWALK
SEE CONTRACT PLANS WIDTH (TYP.)
4'- 0" MIN.

GRADE BREAK

1. Provide a separate Curb Ramp for each marked or unmarked crosswalk.


Curb Ramp location shall be placed within the width of the associated
crosswalk or as shown in the Contract Plans.

WIDTH - SEE CONTRACT PLANS

LANDING

GRADE BREAK

LANDING

NOTES

CURB RAMP WIDTH 4'- 0" MIN. LANDING TO MATCH


CURB RAMP WIDTH - SEE CONTRACT PLANS

0
0

3. Do not place Gratings, Junction Boxes, Access Covers, or other appurtenances in front of the Curb Ramp or on any part of the Curb Ramp or
Landing.
4. See the Contract Plans for the curb design specified. See Standard Plan
F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and
Pedestrian Curb details.

3/8" EXPANSION
JOINT (TYP.)- SEE
STANDARD PLAN F-30.10

CURB RAMP

3/8" EXPANSION
JOINT (TYP.)- SEE
STANDARD PLAN F-30.10

5. See Standard Plan F-30.10 for Cement Concrete Sidewalk details.


See Contract Plans for width and placement of sidewalk.

GRADE
BREAK

GRADE BREAK

6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include
the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter,
Pedestrian Curb, or Sidewalk.
CEMENT CONCRETE
PEDESTRIAN CURB SEE NOTE 4

DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-45.10


FACE OF CURB

DETECTABLE WARNING SURFACESEE STANDARD PLAN F-45.10

FACE OF CURB

MEASURED PARALLEL
TO CURB (TYP.)

~
CROSSWALK

DEPRESSED CURB AND GUTTER SEE NOTE 4

CROSSWALK

DEPRESSED CURB AND GUTTER

l.._

7. The Curb Ramp maximum running slope shall not require the ramp length
to exceed 15-feet to avoid chasing the slope indefinitely when connecting
to steep grades. When applying the 15-foot maximum length, the running
slope of the Curb Ramp shall as flat as feasible.
8. Curb Ramp, Landing, and Flares shall receive broom finish. See
Standard Specifications 8-14.
LEGEND
SLOPE IN EITHER DIRECTION

PLAN VIEW
TYPE PERPENDICULAR A

PLAN VIEW
TYPE PERPENDICULAR B
DETECTABLE WARNING SURFACESEE STANDARD PLAN F-45.10

15'- 0" MAX.


SEE NOTE 7

4'- 0" MIN.


SEE CONTRACT PLANS

SLOPE TREATMENTSEE STANDARD PLAN F-30.10

(SHOWN WITH BUFFER)


GRADE BREAK

DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-45.10

CEMENT CONCRETE
PEDESTRIAN CURB SEE NOTE 4

DEPRESSED CURB AND GUTTER SEE NOTE 4

GRADE BREAK

2.0% MAX.

,. ,

LANDING

8.3% MAX

......

CURB RAMP

SECTION

DEPRESSED CURB AND GUTTER SEE STANDARD PLAN F-10.12

CURB RADIUS DETAIL

CEMENT CONCRETE CURB RAMP "TYPE


PERPENDICULAR B" PAY LIMIT- SEE NOTE 6

PERPENDICULAR
CURB RAMP
STANDARD PLAN F-40.15-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC VIEW
TYPE PERPENDICULAR A PAY LIMIT

ISOMETRIC VIEW
TYPE PERPENDICULAR B PAY LIMIT

......

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

NOTES

MATCH SIDEWALK
WIDTH - 4' 0" MIN.
- SEE CONTRACT PLANS
3/8" EXPANSION JOINT
(TYP.) -SEE STANDARD
PLAN F-30.1 0

2. Curb ramp location shall be placed within the width of the associated

CURB RAMP
PEDESTRIAN CURB
- SEE NOTE 10

MATCH SIDEWALK WIDTH - 4' 0" MIN.


SEE CONTRACT PLANS
LANDING

n
i
-u-

b-"'1,--------+-t---....:...L._

5. See the Contract Documents for the curb design specified.


:Z

:ij

b
;q

SEE NOTE 6

....1
....1

Cl
Cl

6. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details.

en~

en

See contract plans for width and placement of sidewalk.

0:::

7. The bid item "Cement Concrete Curb Ramp Type _" does not include the
adjacent Curb or (Curb and Gutter), Depressed Curb and Gutter, Pedestrian
Curb or Sidewalk, or the pedestrian crossing closure sign.

DETECTABLE WARNING SURFACE


SEE STANDARD PLAN F-45.10

PEDESTRIAN CROSSING
CLOSURE SIGN

PLAN VIEW
TYPE SINGLE DIRECTION A

LlJ

See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb
and Gutter and Pedestrian Curb details.

~
....1

(.)

DETECTABLE WARNING SURFACE


SEE STANDARD PLAN F-45.10

CURB RAMP

8. The curb ramp maximum running slope shall not require the ramp length to
exceed 15 feet to avoid chasing the slope indefinitely when connecting
to steep grades. When applying the 15 foot maximum length, the running
slope of the curb ramp shall be as flat as feasible.

CURB RAMP

9. Curb ramps and landings shall receive broom finish .


See Standard Specifications 8-14.

PLAN VIEW
TYPE SINGLE DIRECTION B

10. Pedestrian Curb may be omitted if the ground surface at the back of the
Curb Ramp and/or landing will be at the same elevation as the Curb Ramp
or Landing and there will be no material to retain.

::::i

0:::
LlJ
LL.

DETECTABLE WARNING SURFACE


-SEE STANDARD PLAN F-45.10

15'- 0" MAX


SEE NOTE 8

GRADE BREAK

Cl

15'- 0" MAX


SEE NOTE 8

GRADE BREAK

GRADE BREAK

LEGEND

15'- 0" MAX


SEE NOTE 8

LANDING

SECTION

DEPRESSED CURB & GUTTER


- SEE STANDARD PLAN F-10.12

SIDEWALKSEE NOTE 6

CURB RAMP

CURB RAMP

SECTION

"CEMENT CONCRETE CURB RAMP


TYPE SINGLE DIRECTION A" PAY LIMIT
- SEE NOTE 7

SLOPE IN EITHER DIRECTION

GRADE BREAK

GRADE
BREAK

SIDEWALKSEE NOTE 6

SIDEWALK
- SEE NOTE 6

CURB RAMP

between the two adjacent surface planes shall be flush.


ences in front of the curb ramp or on any part of the curb ramp or landing.

~ ~SIDEWALK-

c.>

3. Where "GRADE BREAK" is called out, the entire length of the grade break
4. Do not place gratings, junction boxes, access covers or other appurtan-

3/8" EXPANSION JOINT - SEE


STANDARD PLAN F-30.10

PEDESTRIAN CROSSING
CLOSURE SIGN

permitted.
crosswalk, or as shown in the Contract Plans.

PEDESTRIAN CURB
- SEE NOTE 10
PEDESTRIAN CURB
- SEE NOTE 10

1. This plan is to be used where pedestrian crossing in one direction is not

BUFFER
STRIP

MATCH SIDEWALK
WIDTH - 4' 0" MIN.
SEE CONTRACT PLANS

"CEMENT CONCRETE CURB RAMP


TYPE SINGLE DIRECTION B" PAY LIMIT
- SEE NOTE 7
DETECTABLE WARNING
SURFACE -SEE
STANDARD PLAN F-45.10

1" RADIUS
CORNER
PEDESTRIAN CURB

SINGLE DIRECTION
CURB RAMP

DEPRESSED CURB AND


GUTIER - SEE NOTE 5

90" ANGLE

STANDARD PLAN F-40.16-02

RADIUS MAY
VARY

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC VIEW
TYPE SINGLE DIRECTION A
PAY LIMIT

DETAIL

ISOMETRIC VIEW
TYPE SINGLE DIRECTION B
PAY LIMIT

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

h"\

1---A--------!

re-

NOTES

'Y

i
I

c
CURB RAMP, LANDING, CUTTHROUGH OR WALKWAY

'

ub
'
j
---- ~ -----~------@- \
~

Al

DETECTABLE WARNING
SURFACE (DWS) SEE NOTE 3

TRUNCA:DDOME

SECTION

MIN.

MAX.

1.60"

2.40"

0.65"

0.45"

0.90"

0.9"

1.40"

0.2"

0.2"

BACK OF CURBSEE NOTE 2

2'- 0" MIN.TYP. OF ALL


APPLICATIONS

~ COLOR
SEE STANDARD SPECIFICATIONS FOR
OF SURFACE

MATCH TO WIDTH OF CURB RAMP


LANDING, CUT-THROUGH OR
WALKWAY

CURB AND GUTTER

TRUNCATED DOME SPACING


SEE NOTE 3

TRUNCATED DOME DETAILS

DETECTABLE WARNING SURFACE DETAIL


CURB RAMP

1.

The Detectable Warning Surface (DWS) shall extend the full width of the
curb ramp (exclusive of flares) or the landing.

2.

The Detectable Warning Surface shall be placed at the back of curb, and
need not follow the radius.

3.

The rows of truncated domes shall be aligned to be perpendicular to the


grade break at the back of curb.

4.

The rows of truncated domes shall be aligned to be parallel to the


direction of travel.

5.

If curb and gutter are not present, such as a shared-use path connection,
the Detectable Warning Surface shall be placed at the pavement edge.

6.

See Standard Plans for sidewalk and curb ramp details.

7.

If a curb ramp is required, the location of the Detectable Warning Surface


must be at the bottom of the ramp and within the required distance from
the rail.

8.

When the grade break between the curb ramp and the landing is less than
or equal to 5 ft. from the back of curb at all points, place the Detectable
Warning Surface on the bottom of the curb ramp.

LANDING
LANDING

WIDTH OF
WALKWAY

WALKWAY~

I" WIDTH OF CUT-THROUGH

I"

(TYP.)
...J
...J

~II

...~

DETECTABLE WARNING
SURFACE (DWS) SEE NOTE 4

0
0

::J

WIDTH OF CUT-THROUGH
(TYP.)

CURB RAMP
2'- 0" MIN.

BACK OF CURB

0:::

11..

SINGLE DIRECTION CURB RAMP


(GRADE BREAK BETWEEN CURB AND
LANDING s 5 FT. FROM BACK OF CURB)
(SEE NOTE 6)
BACK OF CURB SEE NOTE 2

DETECTABLE WARNING
SURFACE (DWS) SEE NOTE 3

_/I

---1

DETECTABLE WARNING
SURFACE (TYP.) SEE NOTE 3

WIDTH OF CURB RAMP


BACK OF CURB SEE NOTE 2

CURB RAMP

PERPENDICULAR CURB RAMP

WIDTH OF
WALKWAY

WALKWAY~

(SEE NOTE 6)
WIDTH OF CURB RAMP,

""

""

DETECTABLE WARNING
SURFACE (DWS) - SEE NOTE 3

""

0~1~NG, OR WALKWAY

ISLAND CUT-THROUGH
DETECTABLE WARNING
SURFACE (TYP.) SEE NOTE 3

MEDIAN CUT-THROUGH
BACK OF CURB SEE NOTE 2

BACK OF CURB SEE NOTE 2

SINGLE DIRECTION CURB RAMP


(GRADE BREAK BETWEEN CURB AND
LANDING > 5 FT. FROM BACK OF CURB)
(SEE NOTE 6)

DETECTABLE WARNING
SURFACE (DWS)SEE NOTES 4 & 7

WIDTH OF SHARED-

USEPA~~O~

WALKWAY (TYP.)

WIDTH OF CUT-THROUGH
(TYP.)

SHARED-USE
PATH OR
WALKWAY

ROUNDABOUT SPLITTER
ISLAND

DETECTABLE WARNING
SURFACE
STANDARD PLAN F-45.10-01
SHEET 1 OF 1 SHEET

BACK OF CURB SEE NOTE 2

DETECTABLE WARNING
SURFACE (DWS) - SEE NOTE 3
WIDTH OF

PATH OR
WALKWAY

DETECTABLE WARNING
SURFACE (DWS) SEE NOTES 4 & 5

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

LANDING

PARALLEL CURB RAMP


(SEE NOTE 6)

PEDESTRIAN RAILROAD CROSSING

PLACEMENT GUIDELINES

SHARED-USE PATH CONNECTION

......

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

VARIES- SEE CO NTRACT PLANS

'1:r

.,.Jl~.\'?~~

SEE NOTE

T[TYP)- ~
~i~1C~tflli'N

~ -z;/

~/"

~1

N1

f'

VARIES - SEE CON TRACT PLANS


NT (TYP)3/8" EXPANSION JO~N
F-30.10
SEE STANDARD P

CEMENT CONC. P EDESTRIAN CURB (TYP.)


(WHEN SPECIFIE D IN CONTRACT) LAN F-10.12

SEESTz~p

EMENT CONC. SIDEWALK

BROOM ED
FINISH (TYP.)

SEE NOTE 1

DRIVEWAY
ENTRANCE
SIDEWALK
(TYP.)

CEMENT CONCRETE
SIDEWALK

F-30.10

r~

ii ~
,/
0!

~.

3" R.
(TYP.) ~

........

1)

MATCH SIDEWALK WIDTH


SEE CONTRACT PLANS 4' _ 0" MIN.

~~

i
i
i
i

-- .

I
B

PLAN VIEW

CEMENT CONCRETE
CURB & GUTTER
SEE NOTE 3)

TYPE 1
15, MAX. SEE NOTE 6

CE~~~~E~Ng~~T~o~~R3)

_j

VARIES- SEE
GRADE BREAK

.......

----

8.3% MAX.

= ~
co.._.

PEDESTRIAN RAMP
CEMENT CONCRETE
SIDEWALK (TYP.)

SECTION

0
SEE CONTRACT

PLANS

PLANS

.-

SEE CONTRACT PLANS

..:: . .

. . ..

. : .
..

SECTION

0
0

11..

3/8" EXPANSION JOINTJV.~J.1o


- SEE STANDARD PLA

(SEE NOTE 7)

::J

z
a:

;:a;:~~nd~:~
;r~n F-~0.10. ~~~~~~~~t~xf~~=~~ maximum
P

X
~-

arallel with the ~nterhne:d~~s exceed 30 feet.


.
hen dnveway WI
spacmg w
F 30 10 for sidewalk details.
2. See Standard Plan - .
h Contract Plans for the
h
wn
see
t
e
3 . Curb
and gutter ~ o 'See Standard
Plan F- 10.12
cu rb design specified.
.
for Curb Deta1 1s.
.

DRIVEWAY ENTRANCE
SIDE SLOPE (TYP.)

PLAN VIEW

TYPE2
SEE CONTRACT PLANS
_ 4' _ 0" MIN.

1/2" MAX. LIP BETWEi~URB

SEE CONTRACT PLANS

1/2" R. (TYP.)

~~A~E~A6o~~~~~ PLANS '


DEPRESSED CURB &
GUTTER (SEE NOTE 3)

......

2.0% MAX.
,.,.,..

LEGEND
SLOPE IN EITHER DIRECTION

't m does not include driveway.


1
See
Pay Contrac
e
t Plans
ETE DRIVEWAY
"CEMENT CONTYC~E .. PAY LIMITS
ENTRANCE
2

ETE DRIVEWAY
"CEMENT CONTYC~E .. PAY LIMITS
1
ENTRANCE

DRIVEWAY
(SEE NOTE 7)

dep~

.
tructures, junction boxes
4. Avoid placbintg ~~~~~gi~ ~ront of driveway entrances.
h
1/2" MAX. LIP BETWEi~URB
or other o s ru
t the entire length oft e
ROADWAY GUTTER PLANS,
OR SEE CONTRACT
Where "GRADE BRE:~~!~~~~~~ planes shall be flush.
5. line between the two J

I
shall not require the
DEPRESSED CURB
& GUTTER

m
runmng
s
ope
6 The curb ramp maxm~u 15 feet to avoid chasing th e slope
(SEE NOTE 3)
. ramp length to excee
. to steep grades. When
indefinitely when connectl~~ngth the running slope
applying
theramp
15 fo~ ~~~as flat'as feasable.
of the curb
s a

2.0% MAX.

~:;=AYRAMP
....1
....1

3/8" EXPANSION JOINT ~"V-~J.1o


- SEE STANDARD PLA

SEE CONTRACT
1/2" R.
(TYP.)

{.--------------

GRADE
BREAK

2' - 6"

5' - 0"

NOTES
.
5 15 feet, construct a full
1. When the dli."';'vaft, ~~~j;;~~'i!!r along the dli"';j~;~:'nteliln

CONTRACT PLANS

a.:

DRIVEWAY
TAPER (TYP.)

L----',~TY~P:::.)~---r-r,TYTV~:Pil.)

,./--

DRIVEWAY
(SEE NOTE 7)

....

X
~-:.:::

.--------

CEMENT CONCRETE
DRIVEWAY ENTRANCE
TYPES 1, 2, 3 & 4
STANDARD PLAN F-80.1 0-02

..

CL 4000 CONCRETE
PER STANDARD SPEC. 8-06.3

CL 4000 CONCRETE
PER STANDARD SPEC. 8-06.3

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


ISOMETRIC VIEW

ISOMETRIC VIEW

TYPE 1 PAy LIMITS

TYPE 2- PAY LIMITS

STATE DESIGN ENGINEER

03-1D~:12

Washington State DepartmenI of Transportation

--=rI

\_,..

VARIES-

BROOM ED
FINISH ( TYP.)

3/8" EXPANSION JOINT (TYP.)SEE STANDARD PLAN F-30.10

\tn
\\

CEMENT
CONCRETE
SIDEWALK

MATCH SIDEWALK WIDTH


4' - 0" MIN. - SEE
CONTRACT PLANS

\0.

\?l
\

I
I

6'- 0"

6'- 0"

VARIESSEE CONTRACT PLANS

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

1-

{)

~en
~::s
{)D..

1-z

...

w
w

...

en

...

...

w
w

..

en

..

\
\

SEE NOTE 1

BUFFER STRIP (TYP.)

2'- 6"

\
\

(TYP.)

\
\

...J
...J

PLAN VIEW

TYPE3

Cl
Cl

::J

CEMENT CONCRETE
CURB & GUTTER
SEE NOTE 3

DRIVEWAY ENTRANCE
SIDE SLOPE (TYP.)

CEMENT CONCRETE
CURB & GUTTER
SEE NOTE 3

PLAN VIEW

DRIVEWAY ENTRANCE
SIDE SLOPE (TYP.)

TYPE4*

I
\I
\I
\1

0:::

LL.

1/2" R. (TYP.)

SEE NOTE 1

MATCH SIDEWALK WIDTH


SEE CONTRACT PLANS -

*THIS ENTRANCE TYPE SHALL NOT BE USED ALONG A PEDESTRIAN ROUTE

SEE CONTRACT PLANS

SEE CONTRACT PLANS

1/2" R. (TYP.)

SIDEWALK

DRIVEWAY
DRIVEWAY
RAMP

3/8" EXPANSION JOINT (TYP.) SEE STANDARD PLAN F-30.10

(SEE NOTE 7)

DEPRESSED
CURB & GUTTER
SEE NOTE 3

DRIVEWAY
RAMP

SECTION

DEPRESSED
CURB & GUTTER
SEE NOTE 3

SECTION

"CEMENT CONCRETE DRIVEWAY


ENTRANCE TYPE 3" PAY LIMIT
DRIVEWAY
(SEE NOTE 7) ~
CL. 4000 CONCRETE
PER STANDARD SPEC. 8-06.3

"CEMENT CONCRETE DRIVEWAY


ENTRANCE TYPE 4" PAY LIMIT

_..--/

>y:

/ ..

DRIVEWAY

_./
(SEE NOTE 7)

_.../

~---

CEMENT CONCRETE
DRIVEWAY ENTRANCE
TYPES 1, 2, 3 & 4
STANDARD PLAN F-80.1 0-02

CL. 4000 CONCRETE


PER STANDARD SPEC. 8-06.3

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

ISOMETRIC VIEW
TYPE 3 PAY LIMITS

TYPE 4 PAY LIMITS

....

STATE DESIGN ENGINEER

DATE

~ Washington State Department of Transportation

12.0' MIN. - 30.0' MAX.


SHOULDER

NOTES

NOT LESS THAN 6.0'

VARIES - SEE NOTE 3

1. Attach the Milepost Sign Panel to a timber sign post using two 3/8" diameter lag bolts, with washers;
see Standard Plan G-22.1 0. For post and attachment details on steel sign posts, see Standard Plan
G-24.50, Type ST-1.

:--c_ SIGN AND POST


CENTERLINE

2.

Provide Supplemental Plaques and install on Mileposts where indicated in the Contract.

3. See the Contract for the width of the Single-Faced Milepost Signs required (10" or 12").
D10-1, D10-2, & D10-3
MILEPOST SIGN PANEL

4.

For lateral installations behind traffic barrier, 6" high curbs, and ditches, see Standard Plan G-20.1 0.

5.

Install at the locations shown in the Contract. Installation may be moved 50 feet or less (longitudinally)
before or after the contract location if obstructions are encountered, or to utilize the post of another
sign. Mileposts that cannot be placed within this degree of accuracy shall be omitted entirely.

4><4 (NOM.) TIMBER SIGN POST


OR 2"><2" STEEL SIGN POST

1-

TYPICAL INSTALLATION
FOR SINGLE-FACED SIGNS

.z

w
-::!!:
::!!: Cl

~~

C')::i!:
w

TIMBER POST

SHOULDER

1/4" DIAM. >< 3" HEX HEAD


BOLT, NUT & WASHERS
(USE FOR SINGLE-FACE
INSTALLATIONS ALSO)

1/4" DIAM. >< 1 1/2" LAG


BOLT AND WASHER

12.0' MIN. - 18.0' MAX.

IC_

NOT LESS THAN 6.0'

BOLT AND POST


CENTERLINE

STEEL POST

BACK EQUATION
PLAQUE (D10-401)

INSTALL PLAQUE
ON BOTH SIDES

TIMBER POST
SPUR ROUTE PLAQUE
(D10-501)

~-

~:

SINGLE-FACED SIGN
D10-101' D10-201' & D10-301
MILEPOST SIGN PANEL

DOUBLE-FACED SIGN

SUPPLEMENTAL PLAQUE- MOUNTING DETAIL


SEE NOTE 2

4><4 (NOM.) TIMBER SIGN POST


OR 2"><2" STEEL SIGN POST

MILEPOST
STANDARD PLAN G-1 0.10-00
SHEET 1 OF 1 SHEET

TYPICAL INSTALLATION
FOR DOUBLE-FACED SIGNS

1.Z

z w
-::!!:
::!!: Cl
~~

C')::i!:
w

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

------~s=~=TE=o=Es=IG~NE=N=GIN=E=ER~---

09-20-07
DATE

fJ'I Washington State Department of Transportation

12' MIN.
SHOULDER

SHOULDER

w
12'

12' MIN.

MIN.

6'

NOTES

SHOULDER

SIGN

SIGN

6'

MIN.

SIGN

MIN.

Iv

EDGE OF
TRAVELED
WAY

Iv

EDGE OF
TRAVELED
WAY

2. The minimum vertical distance from the


bottom of the sign to the ground shall not
be less than 7' for signs located within the
Design Clear Zone.

EDGE OF
TRAVELED
WAY

(7' MIN.)

(7' MIN.)

(7' MIN.)
FILL SLOPES
STEEPER
THAN 6H:1V

6H:1V SLOPE
OR FLATTER

SLOPE BREAK

SLOPE BREAK

SIGN INSTALLATION
IN FILL SECTION

SLOPE BREAK

SIGN INSTALLATION
ON STEEP FILL SLOPES

MULTIPLE SIGN POST INSTALLATION


IN FILL SECTION

w
3'

12' MIN.

12' MIN.

SIGN
SHOULDER

PRIMARY
SIGN

6'
MIN.

EDGE OF
TRAVELED
WAY

~---li'l'----'['--

~(7' MIN.)

MAJOR SIGN

SHOULDER

0" MIN.
3" MAX.

EDGE OF
TRAVELED
WAY

EDGE OF
TRAVELED
WAY

SECONDARY
SIGN

SUPPLEMENTAL
PLAQUE

_l
TRAFFIC BARRIER

SLOPE BREAK

SLOPE BREAK

SIGN INSTALLATION
BEHIND TRAFFIC BARRIER

SIGN WITH SUPPLEMENTAL


PLAQUE INSTALLATION
IN FILL SECTION

GUIDE OR DIRECTIONAL SIGN WITH


SECONDARY SIGN INSTALLATION ON
EXPRESSWAYS AND FREEWAYS

12' MIN.

SIGN

12' MIN.

:SHOULDER .,I

4'

:1

MIN.

SHOULDER

SIGN

1
v

----Jl:y;:::::::;~~~ r-1

FLATTER THAN 3H:1V

7' MIN.

STEEPER THAN 3H:1V

2' MIN.

4'

SIGN

'

DITCH

r:--

,.....,....~~

DITCH
EDGE OF
TRAVELED
WAY

BACKSLOPE

'

EDGE OF
TRAVELED
WAY

1. Refer to the Sign Specification Sheet of the


Contract for the 'V' and 'W distances.

I:--

EDGE OF
TRAVELED
WAY

(7' MIN.)

(7' MIN.)

~:o...y.r....;;.....:.....:...n...;;.....:....;;.....:.t+-"'

BACKSLOPE

GROUND MOUNTED
SIGN PLACEMENT

II

STANDARD PLAN G-20.10-00

[7'

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
SLOPE BREAK

SIGN INSTALLATION
IN CURB SECTION

SLOPE BREAK

SIGN INSTALLATION
IN DITCH SECTION

MULTIPLE SIGN POST INSTALLATION


IN DITCH SECTION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

09-20-07
DATE

fJ'I Washington State Department of Transportation

NOTES

en
z

1. Notch is only required with multiple post installations.

w
w

a:
[I]

y
~
TO~BF
lc~.....

....1
....1

iii

SIGN

B------,

2. 6x10, 8x10, and 6x12 Timber Sign Posts cannot be made


breakaway and do not have holes or notches. These
posts shall not be installed within the Design Clear Zone.
They may be installed behind traffic barrier.

~TOP OF POST

;5

SIGN PANEL

WIDEST SIGN
POST DIMENSION

======;

Cl

3. Signs with a width less than 12 feet and supported on three


6x6 or 6x8 posts shall not be installed within the Design
Clear Zone. They may be installed behind traffic barrier.
4. Signs with a width less than 17 feet and supported on four
6x6 or 6x8 posts shall not be installed within the Design
Clear Zone. They may be installed behind traffic barrier.

SIGN PANEL
SIGN BRACEWHEN REQUIRED
(STD. PLAN G-50.10)

SIGN PANEL

GALVANIZED
LAG SCREW

z
~
~
Oil..
-'r-- .....
ci

1/)

w
w

For "X", "Y", "H1", "H2", "H3", and "H4" refer to the Sign
Specification Sheet in the Contract.

6. For 6x6 posts and larger, 7 feet minimum spacing is required between posts.

VIEW0

....0 .....
0
N
::c
.c; C)U')

TIMBER SIGN POST

5.

TIMBER SIGN POST SEE STD. SPEC. 9-28

iiiw

POST INSTALLATION TABLE

::CI-

..... o
enz

Ow

POST SIZE
(NOM.)

a.w

=
....

en

FINISHED GROUND
LINE

DRILL PILOT
HOLES FOR
LAG SCREWS

1" DIAM. WASHER, NYLON


OF SIGN

DEPTHSEE POST
INSTALLATION
TABLE

TIMBER
POST

1" DIAM. FLAT WASHER,


STEEL, GALVANIZED

EDGE OF
TRAVELED WAY

3/8" x 3" HEX LAG SCREW,


STEEL, GALVANIZED
SIGN PANEL
DIRECTION OF TRAFFIC ,..,.
DETAIL

ELEVATION VIEW

SINGLE POST INSTALLATION

HOLE
DIAMETER

NOTCH DEPTH
(SEE NOTE 1)

::::.::::::::,

en

COMPACTED NATIVE
BACKFILL MATERIAL

DEPTH

4x4

3'- 0"

NOT REQ'D

NOT REQ'D

4x6

4'- 0"

1 1/2"

1 1/2"

6x6

4'- 0"

6x8

5'- 0"

6x10

6'- 0"

8x10
6x12

2"

2"

SEE NOTE 3 & 4

SEE NOTE 3 &4

3"

3"

SEE NOTE 3 & 4

SEE NOTE 3 &4

SEE NOTE 2

SEE NOTE 2

6'- 0"

SEE NOTE 2

SEE NOTE 2

7'- 0"

SEE NOTE 2

SEE NOTE 2

DRILL HOLES THROUGH POST,


WHEN REQUIRED - SEE POST
INSTALLATION TABLE

FINISHED
GROUND
LINE

TIMBER SIGN SUPPORT


STANDARD PLAN G-22.10-01
SHEET 1 OF 3 SHEETS
APPROVED FOR PUBLICATION
VIEW0

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

"X" SIGN WIDTH


(/)

SEE NOTE 5

w
0:::
w

0.2X

al

0.6X

"X" SIGN WIDTH


SEE NOTE 5

~----------~----------~

0.2X

SEE NOTE 6

....1
....1

6" (TYP.)

SIGN PANEL

ffi

:>-:
al

-_G.-

}-

Cl

0.25X
I 0.25X
I 0.25X
I
I: SEE NOTE 6:SEE NOTE 6:SEE NOTE 6:

1 3/4" X 1 3/4" X 1/4" STEEL


OR ALUMINUM ANGLE

EQUAL SPACING
3'- 0" MAX.

T---

1I-

'-'
iiJ

iiJ w

:I: 1-

z z

1-0

Ow

a. w
= (/)

EDGE OF

-----~-~---

'-' w
Ci5 w

ALUMINUM WINDBEAM AND


TWO POST CLIPS (TYP.) - SEE
SIGN PANEL ATTACHMENT
DETAIL, SHEET 3

cnz

0 w
a. w

(/)

FINISHED
GROUND LINE

w 1:Z::o

3/16" ALUMINUM RIVETS @ 4"


STAGGERED SPACING (TYP.)

' '
' '
' '
' '
' '
-------+----

LO

Q w

:z::

'-'LO

w
:I: I0
I(/)

:z::

1LO

-- - - - - --1- .1
T- --- -

DEPTH - SEE POST


INSTALLATION
TABLE

COMPACTED NATIVE
BACKFILL MATERIAL

0.15X
6" (TYP.)

WINDBEAM
(TYP.)

SEE NOTE 6

_. ci

....1'-'

<Cz
:Jot>

wit
(/)

-------1--r--

:z::

1-

:z::

:z::

'-'LO

ww

LO

'-'LO

'-'

S:2w
w 1:z:: 0

iiJ w

:Z::I-

1-0

cnz

ow
a.w

= (/)

"<I"

I-

a.

en

cnw
Ow

LO

ww

:I: 11-0

1-0

Ow

ow
a.w

= (/)
N

("I)

cnz
a. w

:Z::I-

cnz
= (/)
~

NOTCH DEPTH - SEE


POST INSTALLATION
TABLE

EDGE OF
TRAVELED WAY

'-'

~~

LO

COMPACTED NATIVE
BACKFILL MATERIAL

it:!!
(/) =

wl-

_.a

'-'w
(i)W

<(

'

::J(<)

}-(/)

0
w

&j_ __ _

...0
c,
z z
~

11.

ci

DRILL HOLES THROUGH EACH


POST, WHEN REQUIRED - SEE
POST INSTALLATION TABLE

.:)
I-

'

~7

-------~,---~

en

FINISHED
GROUND LINE

BOTTOM OF SIGN AND


TOP OF NOTCH SHALL
BE ALIGNED

:z:o
zz

w =
me
Cl '
z -

0.15X

S:2w

F--

-:---

::!!~

<(::!!

' '
' '
' '
' '
' '
' '
------L-1----

SEE NOTE 6

1-

FINISHED
GROUND LINE

m
w
w

DIRECTION OF TRAFFIC -.,

SIGN
POST
(TYP.)

r--I-

SIGN PANEL

:z::

:z::

~~
ca.

SEE NOTE 5
0.35X
.035X

------ ~

1-

1-

.C,

~z

"X" SIGN WIDTH

' ''
' '
' '
' '
' '
' --- - - - - - .1' - I

1-

...0

TWO POST INSTALLATION

' '
' '
' '
' '
' '
::::::~~::::

' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' I:::
'
::: :: ::
::::::::r:c::
' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' '
' ' __
______ J_L.

}-(/)

TIMBER SIGN POSTSEE STD. SPEC. 9-28

TRAVELED WAY

...
' '

' '
' '
' '
' '
' '
'
::::: ==' +:::

0.125X (TYP.)

.. ,

SIGN PANEL

:I:

:I:

SIGN
POST
(TYP.)

I-

t/)

'-'
iiJ

0 w
a. w

(/)

:z::

:I:
LO

w
:I: II- 0
(/)

1-

I-

'-'

LO

iiJ w

:I: I-

'-'

LO

ww

I- 0

1-0

0 w
a. w

Ow

N
~

(/)

(/)

FINISHED GROUND
LINE

:Z::I-

cnz

a.w
= (/)
("I)

TIMBER SIGN SUPPORT


EDGE OF
TRAVELED WAY

STANDARD PLAN G-22.10-01

COMPACTED NATIVE
BACKFILL MATERIAL

SHEET 2 OF 3 SHEETS

DEPTH - SEE POST


INSTALLATION
TABLE

THREE POST INSTALLATION

MINIMUM POST HOLE


DIAMETER IS THE WIDEST
POST DIMENSION PLUS 6"

VIEW

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

TOP OF POST

3/16" TUBULAR STEEL- 4" X 4", 4" X 6",


6" X 6", OR 6" X 8" - ASTM A 500 GRADE
B (GALV.) PER AASHTO M111 OR ASTM
A 501 (GALV.) PER AASHTO M 111.

(/)

w
0:::
w

TOP OF
MAJOR SIGN \

al
....1
....1

TOP OF POST

ffi

Cl

T- -c-:::-=--=--=- ~-=-f-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=- fi-=--=--=--=--=- ~


MAJOR SIGN

POST
DRILL TWO 1/2" DIAM. HOLES
THROUGH TUBE AND INSTALL
TWO 3/8" x 3" GALVANIZED - - LAG SCREWS

~!

~~--

'' ''

' '

TOP OF PAVEMENT

~-----~-~--------------------4-~-----,

L-----~~--------------------~-~----~
I
I

I
I

I
I

MAJOR SIGN

I
I

~~:~E:,, t fj--- ---f-:= .:- .:- .:- ~.:- p.:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- .:- ~ .:-!.:- .:- .:- .:- .:- ~
lf
1

~----,-r--------------------T,----

~-----~-r--------------------,-r----~

SECONDARY
SIGN

3/16" ALUM. RIVETS


@ 4" STAGGERED
SPACING (TYP.)

NOTCH LOCATION (TYP.)

..

ALUMINUM WINDBEAM AND


TWO POST CLIPS (TYP.) - SEE
SIGN PANEL ATTACHMENT
DETAIL

...
..

DEPTH - SEE POST


INSTALLATION TABLE

SIGN POST (TYP.)

CONCRETE CLASS 3000

3/8" x 3" HEX LAG BOLT,


STEEL, GALVANIZED2'- 0" MAX. O.C. -STAGGER
OPPOSING BOLTS 1 1/2" MIN.

VARIES
0" TO 3"_L _ _ _ t _ _

EDGE OF
TRAVELED WAY

4" MIN.

TIMBER SIGN POSTSEE STD. SPEC. 9-28

SECONDARY SIGN

ISOMETRIC VIEW

MAJOR AND SECONDARY SIGN INSTALLATION

CONCRETE FOUNDATION SLEEVE DETAIL


TO BE USED WHEN PLACING TIMBER POST IN A PAVED AREA

DIRECTION OF TRAFFIC,..,.

1/2" NOTCH IN EACH POST,


WHEN REQUIRED - SEE
___[
-+-------=~
POST INSTALLATION TABLE

WIDEST SIGN
POST DIMENSION

STEEL OR ALUMINUM
ANGLE (TYP.)

NOTCH DEPTH - SEE


POST INSTALLATION
TABLE

BOTTOM OF SIGN AND


TOP OF NOTCH SHALL
BE ALIGNED

I
SIGN POST

WIND BEAM

VIEW0

WINDBEAM
3/16" ALUM. -+-.__
RIVET (TYP.)

SIGN PANEL

---==---

DRILL PILOT HOLES


FOR LAG BOLTS (TYP.)
TIMBER SIGN
POST- SEE
STD. SPEC. 9-28

TIMBER SIGN SUPPORT


STANDARD PLAN G-22.10-01

POST CLIP (TYP.)

SHEET 3 OF 3 SHEETS

VIEW0

APPROVED FOR PUBLICATION

STEEL OR ALUMINUM
ANGLE (TYP.)

Pasco Bakotich Ill


07-03-08
----------------------STATE DESIGN ENGINEER
DATE
ISOMETRIC VIEW

SIGN PANEL ATTACHMENT DETAIL

.....

fll

Washington State Department of Transportation

NOTES
STEEL PIPE
SIGN POST
ll
Nl

SIGN PANEL

TOP OF

~SIGNPOST

SIGN BRACEWHEN REQUIRED

1. Dimensions for the parts used to assemble the


base connections are intentionally not shown.
Base connections are patented, manufactured
products that are in compliance with NCHRP
350 crash test criteria. The base connection
details are only shown on this plan to illustrate
how the parts are assembled.
2. For Steel Sign Support Foundation, see Standard Plan G-25.1 0.
3.

For "H1" refer to the Sign Specification Sheet


in the Contract.

SIGN PANEL

4. Mounting brackets with steel straps shall be the


stainless steel one bolt, flared leg bracket and
3/4" wide, 0.030" thick strap "Band-it" products
or an approved equal.

SIGN POST

rc)

BOTTOM
OF SIGN

1-

::c

(.!)(")

WUJ
::CI-

t-0

BRACKET
(TYP.)

enz
OUJ
ll.UJ

=
~
~

0
~

en

.(.!)

~ z

~ ~

be..

STEEL PIPE SIGN POST,


DIAM. VARIES - SEE CONTRACT

-' ci

1'- l-

en
LlJ
LlJ

EXPLODED VIEW

en

BREAKAWAY SIGN BRACKET ASSEMBLY


BREAKAWAY
SIGN POST
BRACKET

FINISHED
GROUND
LINE

VIEW0

BOTTOM OF
SIGN POST
BRACKET

ELEVATION

MOUNTING BRACKET
AND STEEL STRAPSEE NOTE 4

1" DIAM. NYLON WASHER


-WHEN SIGN FACE HAS
TYPE 3 OR 4 SHEETING
5/16" DIAM. HEX
HEAD BOLT

1" DIAM. NYLON WASHER


- WHEN SIGN FACE HAS
TYPE 3 OR 4 SHEETING

~~-

MOUNTING BRACKET
AND STEEL STRAP SEE NOTE 4

5/16" DIAM. HEX


HEAD BOLT

STEEL SIGN SUPPORT


TYPEAP
INSTALLATION DETAILS
STANDARD PLAN G-24.10-00

1" DIAM. STEEL


FLAT WASHER

1" DIAM. STEEL


FLAT WASHER

SIGN POST

SIGN POST

SIGN PANEL

SHEET 1 OF 1 SHEET

SIGN PANEL

APPROVED FOR PUBLICATION

SECTION

DETAIL

PERSPECTIVE VIEW

BREAKAWAY SIGN BRACKET ASSEMBLY

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

11-8-07
DATE

fJ'I Washington State Department of Transportation

NOTES

ll
~1

SIGN PANEL

~~
0

TOP OF

~SIGNPOST

SIGN BRACEWHEN REQUIRED


(SEE STANDARD
PLAN G-50.10)

STEEL TUBE
SIGN POST

<D

1. Dimensions for the parts used to assemble the


base connections are intentionally not shown.
Base connections are patented manufactured
products that are in compliance with NCHRP
350 crash test criteria. The base connection
details are only shown on this plan to illustrate
how the parts are assembled.
2. For Steel Sign Support Foundations, see Standard Plan G-25.1 0.

<D

3. For "H 1" refer to the Sign Specification Sheet


in the Contract.

BOTTOM
OF SIGN

SIGN POST

1J:

C)M

w~

SIGN PANEL

:r:o
1-z
cnw

BRACKET
(TYP.)

ow

~(/)
.....
~

.....

ANCHORi.
FERRULE
(TYP.)

c:i

.0
zz
D..

c:::i

STEEL TUBE SIGN POST,


SIZE VARIES- SEE CONTRACT

F--t;

1r___

~~

iS

w
w

BOTTOM~

(/)

ANCHOR
COUPLING
(TYP.)

EXPLODED VIEW

BREAKAWAY SIGN BRACKET ASSEMBLY

OF SIGN

FINISHED
GROUND
LINE

BREAKAWAY
SIGN POST
BRACKET

VIEW0

BOTTOM OF
SIGN POST
BRACKET

ELEVATION
1" DIAM. NYLON WASHER
-WHEN SIGN FACE HAS
TYPE 3 OR 4 SHEETING

3/8" HEX
HEAD NUT

5/16" DIAM. HEX


HEAD BOLT
1" DIAM. STEEL
FLAT WASHER

STEEL SIGN SUPPORT


TYPE AS
INSTALLATION DETAILS
STANDARD PLAN G-24.20-01

STEEL LOCK
WASHER
SIGN POST

SIGN PANEL

DETAIL

SHEET 1 OF 1 SHEET

APPROVED FOR PUBLICATION


PERSPECTIVE VIEW

BREAKAWAY SIGN BRACKET ASSEMBLY

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

"X" SIGN WIDTH


SEE NOTE 3

0
0:::
0

C:S

1. Dimensions for the parts used to assemble


the base connections are intentionally not
shown. Base connections are patented
manufactured products that are in compliance with NCHRP 350 crash test criteria.
The base connection details are only shown
on this plan to illustrate how the parts are
assembled.

PIPE CLAMP (TYP.)

LL.

::::i

NOTES

T-BAR SIGN SUPPORT


SIGN BRACE WHEN REQUIRED
(SEE STANDARD
PLAN G-50.10)

TOP OF

SIGNt

~t
TOP OF
~SIGNPOST

PIPE CLAMP
1IC')

S2w
STEEL
PIPE
CAP
BOTTOM
OF SIGN

wiIo

zz

~en

SIGN
PANEL
SIGN
PANEL

SIGN POST

(.!)C')

iiiw

PIPE CLAMP
(TYP.)

Il1-0

ow
ll..W

....=

~ c

oa::
o(
-r-- cz

II

SIGN
PANEL

iiiw

....
~

= en
....

C)

SIGN POSTSEE NOTE4

z:3
-~~..

For "X", "Y", "H1", and "H2", refer to the


Sign Specification Sheet in the Contract.

4. Sign posts shall be 2 1/2" nominaii.D. galvanized Schedule 80 steel pipe.

ow
ll..W

BOTTOM
OF SIGN

3.

enz

SIGN POSTSEE NOTE4

2. For Steel Sign Support Foundations, see


Standard Plan G-25.1 0.

5.

Il1-0

en

SIGN POSTSEE NOTE4

(.!)C')

enz

....0

1/2" DIAM. X 5 1/2"


HEX BOLT, NUT
AND 2 WASHERS

SIGN
PANEL
II

z- :3II.

T-BARSIGN
SUPPORT

c.!lw
-w

~c

Do not tighten any slip plate bolt to the recommended torque before pretightening
the other bolts. Progressively tighten the
three slip plate bolts in 10 ft-lbs increments,
alternately, to a final torque of 38 ft-lbs on
each bolt.

oa::

o(

F--ri

II)

w
w

II)

VIEW0

VIEW0

w
w

en

SLIP BASE

en

SLIP BASE
ASSEMBLY

FINISHED
GROUND
LINE

SLIP BASE
ASSEMBLY

FINISHED
GROUND
LINE

BOTTOM OF
UPPER SLIP
PLATE

ELEVATION

ELEVATION

TYPE PL SIGN SUPPORT

TYPE PL-T SIGN SUPPORT

DIRECTION
OF TRAFFIC

BOTTOM OF
UPPER SLIP
PLATE

SIGN POST

CAST UPPER BASE

SIGN PANEL
NYLON WASHER- WHEN
SIGN FACE HAS TYPE
3 OR 4 SHEETING

SIGN POST
KEEPER
PLATE

MANUFACTURED
PIPE CLAMP

STEEL FLAT WASHER

5/16" U-BOLT

STEEL SIGN SUPPORT


TYPES PL, PL-T, & PL-U
INSTALLATIONS DETAILS
STANDARD PLAN G-24.30-01

BASE
PLATE

5/16" DIAM. HEX


HEAD BOLT

~-'

SIGN
POST

MANUFACTURED
PIPE CLAMP

5/16" DIAM. HEX


NUT&WASHER

DETAIL

EXPLODED IVEW

PIPE CLAMP AND U-BOLT

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

EXPLODED VIEW

ISOMETRIC VIEW

TYPE PL SIGN SUPPORT

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

STEEL PIPE
CAP (TYP.)

TOPOFSIGN~

1=I

_j =I

:I:

:I:

!
I
i

!:

I!

1!
I

::c
1-C'"l
Qw

~ ~

Ci5 W
= VJ

?-

TACING (TYP.)

'
'
:1

11

:1

i
i

:i
i
II
I
: --_-_-_-,-_-_ -_-_-_;_-_-_-_-_-_-_,-_-_-_ --~---~4-:i -_-_-_-_--!-:!
. ---- --~ -_-_-_-_-<--_-;

--------r-r------

BOTTOM
OF SIGN

:'

Z-BAR (TYP.)
- 3.001. 2.33

C)

I-

en
0
a.
=
::c

z :5a..
~

c
0 a::
<
- c

w
w

SIGN~

BOTTOM
OF SIGN

'

SUPPORT

'--------------""

"

' - -----L---j------L
-. ... - - - - - - ~-:.\1-

'

U-BARSIGN
SUPPORT

SIGN PANEL

~..-,

--......_;

1-

::c

(!)C'"l

w~

:co
ti)z

ow

SIGN
PANEL

~~

.....

1/2" DIAM. X 5 1/2"


HEX BOLT NUT AND
2WASHERS

C)

ow

BOTIOM_;-

OF SIGN

SIGN POSTSEE NOTE4

z:S
~a..

c
oa::
=

::c

BOTTOM
OF SIGN

SIGN POSTSEE NOTE4

<

~~

FINISHED
GROUND
LINE

'

~
U)

U)

1 1

~en

en

U-BAR

&,
'

1-z

w
w

en

'

en

::co
enw

~'-z

Ci5 w

-w
wl-

SIGN POSTSEE NOTE4

T----

(!)C'"l

TOP OF

STEEL PIPE CAP

z 0z

SIGN PANEL

::c

ww
::c I-

::c

I- C'"l
Cl w
~ I-

(!) C'"l

::c

PIPE
CLAMP
(TYP.)

STEEL PIPE CAP

(!)

1-

~1
ll

~SIGNPOST

'

3/16" ALUMINUM
RIVETS@ 6"
SPACING (TYP.)

VARIES
12" MAX.

I-

SIGNt

j ____ _

6"

~SIGNPOST

--------------~--~-----1-

:
' '

TOP OF

STEEL PIPE
CAP (TYP.)

TOP OF

3/16" ALUMINUM
RIVETS@6"

::=t;

C\11

-------+---~

---~--=---=---=---=--~:.=-!-~--=---=---=--=--=---=---=- --=---=---=--=--=---=---=---=---=---=---=--=--=---=---=---=-:-1.=-:~--=---=---=---=---=--~-~

3'- 0"

VARIES
1' -0" MAX.

A--~-------8------~---A

SIGN PANEL

"X" SIGN WIDTH


SEE NOTE3

"X" SIGN WIDTH


SEE NOTE3

SLIP BASE
ASSEMBLY

SIGN POSTSEE NOTE4

w
w

VIEW0
FINISHED
GROUND
LINE

BOTTOM OF
UPPER SLIP
PLATE (TYP.)

en
I

VIEW0

SLIP BASE
ASSEMBLY

BOTTOM OF
UPPER SLIP
PLATE

ELEVATION

ELEVATION

TYPE PL SIGN SUPPORT

TYPE PL-U SIGN SUPPORT

DUAL POST INSTALLATION

II

XII SIGN WIDTH

6'- 0"

8'- 0"

5/16" DIAM. HEX


- - - NUT & WASHER

ALUMINUM
"Z"BAR

10'- 0"

1'- 0"

2'- 0"

3'- 0"

3'- 0"

4'- 0"

4'- 0"

"Y" SIGN HEIGHT


6'- 0"

8'- 0"

10'- 0"

1'- 0"

2'- 0"

3'- 0"

4'- 0"

4'- 0"

4'- 0"

A, B, C, & F, MAY BE INTERPOLATED


FOR INTERMEDIATE SIGN SIZES

SIGN POST
ALUMINUM
RIVET
5/16" U-BOLT

5/16" DIAM. HEX


HEAD BOLT

MANUFACTURED
PIPE CLAMP

STEEL SIGN SUPPORT


TYPES PL, PL-T, & PL-U
INSTALLATIONS DETAILS
STANDARD PLAN G-24.30-01
SHEET 2 OF 2 SHEETS

SIGN
PANEL

APPROVED FOR PUBLICATION

DETAIL

02-07-12
Pasco Bakotich Ill
-----------------------STATE DESIGN ENGINEER
DATE

.....

. . . Washington State Department of Transportation

"X" SIGN WIDTH


SEE NOTE2

NOTES
1. For "W", Horizontal distance from edge of traveled way to center
of nearest post, and "V", Vertical distance from edge of traveled
way to bottom of sign, see Standard Plan G-20.1 0.

I-------

SIGN PANEL
SIGN BRACE - 36" OR
LARGER IN WIDTH
REQUIRED

0.20X

0.60X

6"

2. For "X", "Y", "H1", "H2", "H3", and "H4" refer to the Sign Specification Sheet in the Contract.

I-

3/8" DIAMETER HEX


HEAD BOLT, NUT
AND WASHERS
(TYP.)

(9N

ww
I 1-

1-0

enz

3. Top of concrete foundations shall be smooth, dense and uniform


to finished groundline

Ow
c.. w
;_en

BOTTOM
OF SIGN

SIGN POST

l-

-w
en en

SIGN POST- 2 1/2" SQUARE,


12 GAGE STEEL TUBE

FINISHED
GROUND
LINE

....1
....1

Cl
Cl

::::i

SIGN POST

(9N

-w
wi-

.....
0

{TYP.)

SIGN POST- 2 1/2"


SQUARE, 12 GAGE
STEEL TUBE (TYP.)

I-

c!>

(9N

w~

b~

SIGN PANEL

SIGN POST

Io

tnz

'C
r-.a::
~
z

VIEW0

SLIP BASE ASSEMBLY (TYP.)

~tlj
= en
.....

1 3/4" X 1 3/4" X 1/4"


ALUMINUM ANGLE
(TYP.)

U)

w
w

en

ELEVATION

WINDLOAD FOR SQUARE TUBE POSTS AT 90 MPH

2 1/2" PSST

1 POST

2POST

3POST

12 GAGE

172

344

516

* 2 1/2" PSST with 2 1/4" insert

12 GAGE

309

618

927

?GAGE
471
942
SLIP BASE REQUIRED (UNLESS BEHIND BARRIER)

BOTTOM
OF SIGN

COMMERCIAL GRADE
CONCRETE (TYP.)

VIEW0

18" DIAMETER (TYP.)

Cl

* 3" SOLID POST

3/8" DIAMETER X 4 1/2"


LONG HEX HEAD BOLT
WITH WASHER & NUT
(TYP.)- 2'- 0" MAX. O.C.

LOWER SIGN POST SUPPORT


- 3" SQUARE, 7 GAGE STEEL
TUBE (TYP.)

SLOPE BREAK

MAXIMUMXYZ

POSTS

~1

I-

0
w

= en

OF SIGN

w
u.

::JC<l

TOP OF

BOTTOM
OF SIGN

BOTTOM~

0:::

TOP OF SIGN

TOP OF LOWER
SLIP PLATE

LOWER SIGN POST


SUPPORT- 3" SQUARE,
7 GAGE STEEL TUBE

18" DIAMETER

WINDBEAM (TYP.)

Io
tnz
ow
c..W

VARIES-i.-

COMMERCIAL GRADE
CONCRETE

Z-BAR (3.001. 2.33)

IO ~:2
zZ en
= -
_.a
e>w <(

SIGN PANEL

SLIP BASE
ASSEMBLY

(9

IN z
~w
WI- (3~

ELEVATION
DUAL POST INSTALLATION

1413

(MAXIMUM 3 SLIP BASES ALLOWED IN 7' SPAN)

NYLON WASHER - WHEN SIGN


FACE HAS TYPE Ill, IV, VIII,
OR IX SHEETING

SIGN PANEL

0
0

3/8" DIAMETER x 3 1/2" LONG


HEX HEAD BOLT

3/8" HEX
HEAD NUT

0
0
0
0

ALUMINUM
RIVET

~~~~~~o~~~~~~

0
0
0

1" DIAMETER STEEL


FLAT WASHER (TYP.)
SIGN PANEL

3/8" DIAMETER x 3 1/2" LONG


HEX HEAD BOLT
STEEL LOCK
WASHER

~~~~~

o-_-_-_-_-_

0
0

SIGN POST

STEEL OR ALUMINUM
ANGLE

SIGN PANEL
SIGN POST

SIGN POST

3/16" RIVETS 4" STAGGERED


SPACING

STEEL SIGN SUPPORT


TYPES SB-1, SB-2 & SB-3
INSTALLATION DETAILS
STANDARD PLAN G-24.40-03

3/8" HEX HEAD NUT


1" DIAMETER STEEL
FLAT WASHER

SHEET 1 OF 4 SHEETS
APPROVED FOR PUBLICATION

DETAIL

FIELD DRILLED Z-BAR

(";;'\

DETAIL~

STEEL SIGN SUPPORT TYPE SB-1, SB-2 & SB-3 - 8"

WINDBEAM

DETAIL

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

ASSEMBLY NOTES

....1

....1

<(

CO:!:

c
c
::::i
z

<(

TRAFFIC
FLOW p;

= ~

....1
....1

1. Dimensions for the parts used to assemble the base connections are intentionally not shown.
Base connections are patented, manufactured products that are in compliance with NCHRP
350 crash test criteria. The base connection details are only shown on this plan to illustrate
how the parts are assembled.

= ~

CO:!:
0

2. Do not tighten any single Slip Plate Bolt to the recommended torque before pre-tightening the
other bolts. Progressively tighten the three Slip Plate Bolts in 10 ft-lb increments, alternately,
to a final torque of 40 ft-lbs on each.

SLIP PLATE DETAIL


FOR TYPE SB-1

0:::

w
u.

:>:

III

\\;)

\\;)
\\;)
\\;)

2 1/2" 12 GAGE
SIGN POST

\\;)
\\;)
\\;)
\\;)
\\;)
\\;)
\\;)

rJ
rJ
rJ
rJ
rJ
rJ
rJ
rJ
rJ
rJ
rJ

\\;)
\\;)
\\;)
\\;)

rJ
rJ
rJ
rJ

\\;)

2 1/2"- 12 GAGE
SIGN POST

\\;)
\\;)

rJ
rJ
rJ
rJ

rJ
rJ
rJ
rJ
rJ

())

rJ

())

())

\\;)

~
~
~

~
~

@;

rJ

())

STEEL TUBING

~/~

UPPER SLIP
PLATE

FILLET WELD

SIGN POST
SUPPORT

,<"
1

FILLETWELD

//

UPPER SLIP
PLATE

UPPER SLIP
PLATE

~/

['.
'

SHOULDER COLLARED
BOLT{TYP.)

TEFLON GASKET

....

KEEPER
PLATE

BEARINGS
{TYP.)

SHOULDER COLLARED
I
BOLT-{TYP.)

)@Y

ISOMETRIC VIEW

ISOMETRIC VIEW

ISOMETRIC VIEW

:--.
I

BALL BEARING
HOUSING

'

LOWER SLIP
PLATE
LOWER SLIP PLATE STUB
{LOWER SIGN POST

LOWER SLIP
PLATE

LOWER SLIP
PLATE

LOWER SLIP PLATE STUB


{LOWER SIGN POST
SUPPORT NOT SHOWN)

'TSHOWN)
LOWER SLIP PLATE STUB
{LOWER SIGN POST
SUPPORT NOT SHOWN)

'

'
SLIP PLATE BOLTS---=~-- SEE ASSEMBLY NOTE 2
FOR TORQUE REQUIREMENTS

EXPLODED VIEW

TYPE SB-1
SLIP BASE ASSEMBLY

SLIP

PLATE~

---"""'-- SEE ASSEMBLY NOTE 2


'
FOR TORQUE REQUIREMENTS

EXPLODED VIEW

TYPE SB-2
SLIP BASE ASSEMBLY
STEEL SIGN SUPPORT TYPE SB-1, SB-2 & SB-3 - 8"

SLIP PLATE BOLTSSEE ASSEMBLY NOTE 2


FOR TORQUE REQUIREMENTS

STEEL SIGN SUPPORT


TYPES SB-1, SB-2 & SB-3
INSTALLATION DETAILS
STANDARD PLAN G-24.40-03
SHEET 2 OF 4 SHEETS

EXPLODED VIEW

TYPE SB-3
SLIP BASE ASSEMBLY

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

TOPOFSIGN~

SIGN PANEL

____

SEENOTE2
TOP OF

13/4" X 1 3/4" X 1/4"


ALUMINUM ANGLE
(TYP.)

1. For "W", Horizontal distance from edge of traveled way


to center of nearest post, and "V", Vertical distance
from edge of traveled wayto bottom of sign,
see Standard Plan G-20.1 0.
2. For "X", "Y", "H1", "H2", "H3", and "H4" refer to the Sign
Specification Sheet in the Contract.

VARIESi __
1-

::c
w w
::c 1-

~-~~~~~~~~~~~~~~

S2N

''
''
''
''
''
"'
''

1-0

rnz

Ow
D.. w
;._oo

...ci

c;

3/8" DIAMETER HEX


HEAD BOLT, NUT
AND WASHERS
(TYP.)

Z-BAR (3.001. 2.33)

SIGN POST

WINDBEAM (TYP.)

1::CN

4.

S2w
C!JW

TOP OF SIGN

::c

C!)N

-w
wl-

SEE STANDARD PLAN G-24.60-01 __/


FOR Z BAR AND WIND BEAM

::co

BOTTOM
OF SIGN

~z

...ci

(TYP.)
1-

c;

::c

C!)N

iii~

b~

BOTTOM_/
OF SIGN

~z

'0

lrtll
= rn

...~

~
z
i:!:
II)

VIEW

SIGN POST - 3"


SQUARE, 7 GAGE
STEEL TUBE (TYP.)

STEEL OR
ALUMINUM
ANGLE (TYP.)

WIND BEAM

::::i

ELEVATION

w
u.

3/8" DIAMETER x 4 1/2"


LONG HEX HEAD BOLT
WITH WASHER & NUT
(TYP.)- 2'- 0" MAX. O.C.

LOWER SIGN POST


SUPPORT- 3" SQUARE,
7 GAGE STEEL TUBE
(TYP.)
SIGN PANEL
COMMERCIAL GRADE
CONCRETE (TYP.)

SLOPE BREAK

WINDBEAM CLIP
(TYP.)

SIGN POST

0
0

0:::

1 3/4" X 1 3/4" X 1/4"


ALUMINUM ANGLE
(TYP.)

SIGN PANEL

TOP OF LOWER
SLIP PLATE

w
w
rn

SIGN POST

SLIP BASE ASSEMBLY


(TYP.)

:co

r-..o:::

....1
....1

BOTTOM
OF SIGN

VIEW0

" DIAMETER (TYP.)

POST CLIP (TYP.)

ELEVATION
DUAL POST INSTALLATION
SECTION

NYLON WASHER- WHEN


SIGN FACE HAS TYPE Ill, IV,
VIII, OR IX SHEETING

SIGN POST

ow
o_W

COMMERCIAL GRADE
CONCRETE

TOP OF

= rn

TOP OF LOWER
SLIP PLATE
VARIES-i--

LOWER SIGN POST


SUPPORT- 3" SQUARE,
7 GAGE STEEL TUBE

~I

1-

SIGN POST - 3" SQUARE,


7 GAGE STEEL TUBE

SLIP BASE
ASSEMBLY

Field drill posts to accept angle and cold galvanized holes.

zZ

SIGN PANEL

-w
rnrn

b~

3. Top of concerte foundation shall be smooth, dense and


uniform to finished groundline.

WI::CO

FINISHED
GROUND
LINE

NOTES

6"

1,1

''
''
''
''
''

0.60X

#SIGNPOST

SIGN BRACE36" OR LARGER


IN WIDTH REQUIRED

BOTTOM
OF SIGN

_j

~---'-'X_"_S_IG_N_W_ID_T_H

SIGN PANEL
STEEL OR ALUMINUM
ANGLE

SIGN PANEL
3/8" HEX
HEAD NUT

3/8" DIAMETER
X 4 1/2" LONG
HEX HEAD BOLT

ALUMINUM
RIVET

SIGN POST
SIGN POST

3/16" RIVETS 4" STAGGERED


SPACING

STEEL LOCK
WASHER

1" DIAMETER STEEL


FLAT WASHER (TYP.)

3/8" DIAMETER
X 4 1/2"LONG
HEX HEAD BOLT

SIGN PANEL

WINDBEAM CLIP
(TYP.)

3/8" HEX HEAD NUT


1" DIAMETER STEEL
FLAT WASHER

SIGN POST

STEEL SIGN SUPPORT


TYPES SB-1, SB-2 & SB-3
INSTALLATION DETAILS
STANDARD PLAN G-24.40-03
SHEET 3 OF 4 SHEETS

DETAIL

FIELD DRILLED Z-BAR - - -

f.\
DETAIL~

DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

STEEL SIGN SUPPORT TYPE SB-1, SB-2 & SB-3 - 10"

ASSEMBLY NOTES

....1
....1

c
c
::::i
z

1. Dimensions for the parts used to assemble the base connections are intentionally not shown.
Base connections are patented, manufactured products that are in compliance with NCHRP
350 crash test criteria. The base connection details are only shown on this plan to illustrate
how the parts are assembled.

0:::

w
u.

TRAFFIC
FLOW

2. Do not tighten any single Slip Plate Bolt to the recommended torque before pre-tightening the
other bolts. Progressively tighten the three Slip Plate Bolts in 10 ft-lb increments, alternately,
to a final torque of 40 ft-lbs on each.

0
.....

--SLIP PLATE DETAIL


FOR TYPE SB-1

3" - 7 GAGE STEEL


SIGN POST

<i!

TRAFFIC
FLOW pa

~
0

0
.....
I})

3" - 7 GAGE STEEL


~SIGNPOST

I})
I

SIGN POST
BRACKET

SIGN POST
SUPPORT

dI

SLIP PLATE DETAIL


FOR TYPE SB-3

I})
I})

UPPERSLIP
PLATE
SHOULDER COLLARED

"h..

,~LTaYPI

. :

UPPER SLIP
PLATE

FILLET
WELD (TYP.)
TEFLON GASKET

r--.
. '
I

KEEPER PLATE

LOWER
SLIP PLATE

'

LOWER SLIP PLATE


LOWER SLIP PLATE
LOWER SLIP PLATE STUB
(LOWER SIGN POST
SUPPORT NOT SHOWN)

LOWER SLIP PLATE STUB


(LOWER SIGN POST
SUPPORT NOT SHOWN)

ISOMETRIC VIEW

ISOMETRIC VIEW

---=,;;;....__

SLIP PLATE BOLTSSEE ASSEMBLY NOTE 2


FOR TORQUE REQUIREMENTS

EXPLODED VIEW

TYPE SB-1
SLIP BASE ASSEMBLY

SLIP PLATE BOLTS__,___ SEE ASSEMBLY NOTE 2


FOR TORQUE REQUIREMENTS

STEEL SIGN SUPPORT


TYPES SB-1, SB-2 & SB-3
INSTALLATION DETAILS
STANDARD PLAN G-24.40-03
SHEET 4 OF 4 SHEETS

EXPLODED VIEW

STEEL SIGN SUPPORT TYPE SB-1 & SB-3 - 10"

TYPE SB-3
SLIP BASE ASSEMBLY

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

NOTES

SIGN PANEL

SIGN POST- 2 1/4"


SQUARE, 12 GAGE
STEEL TUBE

SIGN POST - 2" OR


2 1/4" SQUARE, 12
GAGE STEEL TUBE

t!J
z
~

D..

1-

FINISHED
GROUND
LINE

U)

w
w

en

SIGN BRACE, WHEN


REQUIRED -SEE
STD. PLAN G-50.1 0

DRIVE RIVET
OR CORNER
BOLT WITH NUT
AND WASHERS
-2 REQUIRED

...0
I-

(.9

enz

ow
a.w

='

....1
....1

...0

(.9

w wN

en b
z

D..

0
a. w
w

=
.....

U)

w
w

I-

1-

1-

FINISHED
GROUND
LINE

2. For "H 1" refer to the Sign Specification Sheet in the Contract.

1-

t!J
z

FINISHED
GROUND
LINE

=' en

_....J

a.W

TOP OF LOWER
SQUARE TUBE

II1-0

SIGN POST - 2" OR


2 1/4" SQUARE, 12
GAGE STEEL TUBE

Iw
1- 1-0
en
oz

-N

ww

(.9N

en

...0

BOTTOM
OF SIGN

t!J
z

~~

0
0

i--D..

STABILIZER FIN

0:::

w
u.

(t)

(t)

LOWER SIGN POST


SUPPORT- 2 1/2" SQUARE,
12 GAGE STEEL TUBE

:>-:

IIl

I - I

FINISHED
GROUND
LINE

CLEAN-OUT BAR

(t)

(t)

COMPACTED NATIVE
BACKFILL MATERIAL

I - I

ANCHOR
LEG ANGLE

COMPACTED NATIVE
BACKFILL MATERIAL

= en
.....

1-

U)

w
w

~L

en

l/
:

TOP OF LOWER
sQu:RE TUBE

ELEVATION

TYPE ST-1 SIGN SUPPORT

TYPE ST-2 SIGN SUPPORT

SIGN POST
SIGN PANEL

II

ELEVATION
BOLT STOP
FOR SIGN POST

TYPE ST-3 SIGN SUPPORT

ELEVATION

3. A 2" post with a 2 1/4" PSST anchor, or a 2 1/4" post with a


2 1/2" PSST anchor may be substituted.See Contract Plans.

w~
Io
!i)z
ow
a.W

en

:J

1. Dimensions for the parts used to assemble the base connections are intentionally not shown. Base connections are
patented, manufactured products that are in compliance with
NCHRP 350 crash test criteria. The base connection details
are only shown on this plan to illustrate how the parts are
assembled.

LOWER SIGN POST SUPPORT 3", 7 GAGE, HOT-DIP GALV.,


HEAVY DUTY ANCHOR

0
0
0
0
0
0
0
0
0
0

COMMERCIAL CONCRETE
NYLON WASHER- WHEN
SIGN FACE HAS TYPE Ill, IV,
VIII, OR IX SHEETING

OF SIGN

ELEVATION
3/8" HEX
HEAD NUT

1" DIAM. STEEL


FLAT WASHER

~
0
0

3/8" DIAM. X 3 1/2" LONG


HEX HEAD BOLT

SIGN POST

1" DIAM. STEEL


LOCK WASHER

SIGN PANEL
SIGN POST

DETAIL

0
0
0
0
0

0
0
0
0
0

0
0

~
0
0

0
0

0
0
0
0

0
0
0
0

0
0
0
0

STABILIZER FIN

STEEL SIGN SUPPORT


HEX BOLT WITH NUT
TYPES ST-1 - ST-4
ANDWASHER(TYP.)
INSTALLATION DETAILS
STANDARD PLAN G-24.50-02

LOWER SIGN
POST SUPPORT

SIGN POST
0

0
0
0
0

0
0
0
0
0
0

c
0

TYPE ST-1

0
0
0
0

SIGN POST

SIGN POST

VIEW0

TYPE ST-4 SIGN SUPPORT

ANCHOR
HEX BOLT WITH NUT LEG ANGLE
AND WASHER (TYP.)

LOWER SIGN
POST SUPPORT

SHEET 1 OF 1 SHEET

CLEAN OUT
BAR

APPROVED FOR PUBLICATION


BOLT STOP
FOR SIGN POST

BOLT STOP
FOR SIGN POST

TYPE ST-2

TYPE ST-3

TYPE ST-4

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

yj, Washington

6120113
DATE

Stote Department of Transportation

NOTES

"X" SIGN WIDTH


SEE NOTE 3

SEE NOTE 3

0.60X

Z-BAR - 3.001_ 2.33

I EQ~~ ~~~

"X" SIGN WIDTH


0.20X
Z-BAR - 3.001_ 2.33

1LI

f-- (- -=-~ ::~~~11~:=: -=:~;: :~:~:-:


:=:

- :~ :,=-==:. :=::~==

:-:-:::!..._:_::-:

---~-~-------------------~+----,

1J:

(!)

1-

HINGE
PLATE
(TYP.)

J:

w
1z 0z
(!)
1i5 w
w
(/)
[i

J:

~~~

(!)<')

Liiw

J:t-

t-0

rnz
Ow
c..w

1- - - - - - -r
'

------

-~-

'

-~-----

-~-----

- - - - - - -r
'

------

-~-

'

-~---

-~

-~----

1J:

_______ L_I_ ___ _

(!)<')

- - - - - - -L-

[i w

' '
' '

J: II- 0

rnz
Ow
c.. w
N rn

For Steel Sign Support Foundations, see Standard Plan G-25.1 0.

3.

For "X," "Y," "H 1," "H2," and "H3," refer to the Sign Specification
Sheet in the Contract.

~w

4. Maximum of 34 lbs./ft. in a seven foot wheel path.

zz
<!>w
-w

5. On fill slopes, the maximum sign height is nine feet for posts closest
to the edge of traveled way.

::::::::::::::::::::::::::::~:::::::::::::::::::::1

' '

~(/)

?-

1-

WINDBEAM

...0
0

c!>

z
~

BOTTOM OF
SIGN POST
BRACKET (TYP.)

~
a..
c

(/)

TYPE TP-A OR TP-B SIGN SUPPORT

EDGE OF
TRAVELED WAY

=======~ =:= ===~

WIDE FLANGE
STEEL SIGN POST

J:

(!)<')

[i w
J: I-

HINGE
PLATE
(TYP.)

b 1%:
'
r-. z~

ELEVATION

-:i_

-1-----

' '

-------I- -I-----------I- -I-----

STEEL SIGN POST (TYP.)


- SEE CONTRACT PLANS
FOR POST SIZES

J:C')
WtJ:o

~en

2.
C')

---=====----c...---+:t----+-----H-----1'_ __ }----~-~-------------------~+-----

1. Dimensions for the parts used to assemble the base connections


are intentionally not shown. Base connections are patented,
manufactured products that are in compliance with NCHRP 350
crash test criteria. The base connection details are only shown
on this plan to illustrate how the parts are assembled.

0.15X
6" (TYP.)

------~~

TOP OF SIGN

0.35X

6" (TYP.)

''
I I
WINDBEAM

0.35X

t-O

rnz
ow
c.. w
1-

1-

=
C')

(!) C')

(!) C')

J:

[i w
J: 11- 0

rnz
Ow
a.. w
(/)
~

J:

[i

(/)

J:l-

t-0

rnz
ow
c..w
(/)

w
w
(/)

STEEL SIGN POST


- SEE CONTRACT
PLANS FOR POST
SIZE

BRACKET
(TYP.)

BOTTOM OF
SIGN POST
BRACKET (TYP.)

TOP OF

ELEVATION

EXPLODED VIEW

TYPE TP-A OR TP-B SIGN SUPPORT

TYPE TP-B BASE

SIGNPOST

ALUMINUM WIND BEAM


AND TWO POST CLIPS (TYP.)
- SEE WINDBEAM AND SIGN
POST CONNECTION

SIGN PANEL

(!)

WIDE FLANGE STEEL


SIGN POST - SEE
CONTRACT FOR SIZE

~~
<( ::!:

c.. me
:5<->
_J

WIDE FLANGE
STEEL SIGN POST

'

O@)

STEEL SIGN SUPPORT


TYPES TP-A AND TP-B
INSTALLATION DETAILS
STANDARD PLAN G-24.60-02

HINGE POINT

-1
I

BOTTOM
OF SIGN

BREAKAWAY
HINGE PLATES

VIEW

ANCHOR
COUPLING
(TYP.)

ANCHOR~

FERRULE
(TYP.)

'I

BRACKET
(TYP.)

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION
EXPLODED VIEW

TYPE TP-A BASE

PERSPECTIVE VIEW

TYPE TP-A BASE


(W6x9)

PERSPECTIVE VIEW

TYPE TP-B BASE


(W6x12 OR LARGER)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

TOP OF
MAJOR SIGN \_,__M...Li- Z-BAR- 3.001_2.33

JMAX.l

1-

TOP OF SIGN

::c

EQUAL SPACING
@ 3'- 0"

~M

-o
0::: I-

(!)C'l

- w
w 1-

MAJOR SIGN

::Co
z z

~ b Qw
C/)W
Cl)

SECONDARY SIGN

SUPPLEMENTAL PLAQUE

1-

::c

(!)(")

[j w

::c 11-0

Ow
a. w

...ci
.o
z z
~ :5
b II..
.c
i'- III)

EDGE OF

w
w

Cl)

TRAVELED WAY

ALUMINUM WIND BEAM AND TWO


POST CLIPS {TYP.) - SEE WINDBEAM
AND SIGN POST CONNECTION

3/16" ALUM. RIVETS@ 4"


STAGGERED SPACING {TYP.)

CI)Z

WIDE FLANGE
STEEL SIGN POST

NCI)

I-

::c
Q (")
w w
::c I-

I-

:Z

io

Cl)

Z-BAR

3/8" DIAM. WITH TWO FLAT WASHERS


AND ONE LOCKNUT PER BOLT FIELD DRILL Z-BAR

Z-BAR

a. w
w
Cl)

BOTTOM OF SIGN
POST BRACKET
{TYP.)

...~

WIDE FLANGE STEEL SIGN POST


- SEE CONTRACT FOR SIZE

ELEVATION

(BOLT ON ONE SIDE OF EACH


WIDE FLANGE STEEL SIGN POST)

SECONDARY SIGN

BOTTOM OF
SECONDARY SIGN \

DETAIL

BREAKAWAY
HINGE PLATE

~[ - -

MAJOR AND SECONDARY


SIGN SUPPORT INSTALLATION

SIGN PANEL

VIEW0
WIDE FLANGE
STEEL SIGN POST
{UPPER SECTION)

HINGE POINT
WIDE FLANGE
STEEL SIGN POST

WIDE FLANGE
STEEL SIGN POST
{LOWER SECTION)

3/16" ALUMINUM RIVET

BREAKWAY
HINGE PLATES
{TYP.)

POST CLIPS

STEEL SIGN SUPPORT


TYPES TP-A AND TP-B
INSTALLATION DETAILS
STANDARD PLAN G-24.60-02
SHEET 2 OF 2 SHEETS

PERSPECTIVE VIEW

ISOMETRIC VIEW

BREAKAWAY HINGE PLATE


CONNECTION

WINDBEAM AND SIGN


POST CONNECTION
{ATTACH POST CLIPS ON BOTH SIDES OF WIDE FLANGE STEEL SIGN POST)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

BREAKAWAY SIGN BRACKET


ASSEMBLY - SEE STANDARD
SLIP BASE ASSEMBLYPLAN G-24.10 & G-24.20
SEE STANDARD PLAN G-24.30
MANUFACTURERSUPPLIED CONCRETE
ANCHOR FERRULES

DIRECTION
OF TRAFFIC .,._

NOTES

SIGN POST
BOTTOM OF UPPER

J/
:!:=M

~~

2"CHAMFER

SLIP PLATE
FINISHED
GROUND
LINE

1. Per TRANSPO: 5" to 8" square steel


posts are acceptable and require type
TP-B foundations.
2.

Install conduit for post-mounted Junction


Box in the concrete foundation, when
required. See Standard Plan J-40.35,
Sheet 2.

;r

w:!:
zo
Ol-

2"CHAMFER

d)

CONCRETE
CLASS 4000P

en
w
0::

#5 BAR (TYP.)
EVENLY SPACED

w
en_.
wm
0::~

::Cw
a.m

1-_.

~~

~tll

PLAN VIEW

zw
ow

en

~en

z
::::l

u.

8- #5 BARS

DIRECTION OF TRAFFIC

:em
uo
t::z
0.<(
=
a.
coo
::C!t::l$:<C
a.z
oo::
O::::l
::cl_.w
~tii
.....
a. a.
en:!:

en
w
#5 BAR (TYP.)
EVENLY
SPACED

0::

b
'

&,

::Cw
1-_.
a.m

~~

KEYNOTES

Foundation depths based on allowable


lateral bearing pressure in excess of
2500 PSF.

zw
Ow

~en

::::l

~1: I

;;t8

CONCRETE
CLASS 4000P

u.

--++

;r
TYPE TP-A OR TP-B BASE SEE STANDARD PLAN
G-24.60 FOR DETAILS

~ Two-post installation.

q>

Single-post installations require square


steel posts. For single-post installations,
divide the post MAX. XYZ in half.

ELEVATION VIEW

MANUFACTURER-SUPPLIED
CONCRETE ANCHOR
FERRULES

TYPE PL, TYPE PL-T & TYPE PL-U FOUNDATION

FINISHED
GROUND
LINE

2"CHAMFER

TYPE AS & TYPE AP FOUNDATION

TYPE PL, TYPE PL-T & TYPE PL-U


FOUNDATION TABLE

TYPE AS FOUNDATION TABLE


MAX.XYZ
POST SIZE I MAX. XYZ I FDN. DIAM.I FDN. DEPTH 0
4" SQ.

REINF. BARS
EVENLY SPACED
-SEE TABLE

en
w

250

18"

4'- 0"

FDN.DEPTH0

225

3'- 6"

265

4'- 0"

300

4'- 6"

600~

4'- 6"

TYPE AP FOUNDATION TABLE

0::

::Cw
1-_.
a.m

~~

zw
Ow

~en

POST SIZE

MAX.XYZ

3" O.D.

225

18"

0
X(FT)

3'- 6"

3 1/2" O.D.

250

18"

4'- 0"

4" O.D.

275

24"

4'- 0"

300

24"

4'- 0"

4 1/2" O.D.

z
::::l

FDN. DIAM. FDN.DEPTH

SIGN WIDTH

Jn L..,<~---i-r

ySIGN
HEL_HT

----:-- ___.1Y'2 (FT)


--+l:_
_
: ,

' '
' '

u.

TYPE TP-A & TYPE TP-B FOUNDATION


SIGN PANEL
CONCRETE
CLASS 4000P

TYPE TP-A & TP-B FOUNDATION TABLE


POST SIZE

MAX.XYZ

ASTMA36 ASTMA992 2 POST(3) 3POST


W6x9

1570

W6x 16

W6x 12

W8x21

W8x 18

W10 X 26

W10 X 22

W6x 12

ELEVATION VIEW

STEEL SIGN SUPPORT


FOUNDATION DETAILS

SIGN SUPPORT

SEE NOTE 1

W12 X 30

W12 X 26

VERTICAL
REBAR

FDN. 0
DEPTH

2355

8-#5

2340

3510

8-#5

5'- 0"

4120

6180

8-#6

7'- 0"

6320

9480

8-#7

8'- 0"

8700

---

8-#7

STANDARD PLAN G-25.10-04


FINISHED
GROUND LINE

4'- 0"

9'- 0"

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

XYZ CALCULATION
XYZ (F~) = X X y X z
USED TO DETERMINE POST SIZE
-SEE FOUNDATION TABLES

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

NOTES

X = 4' - 0" OR LESS


....1
....1

6"
MIN.

0
0

::::i

X/4

X/4

WINDBEAM
{TYP.)

1. Mounting brackets with steel straps shall be a stainless

1'- 0' MIN.


2'- 6" MAX.

steel band and buckle system product or an approved


equal. Mounting brackets shall be universal channel
clamps; steel straps shall be 3/4" wide and 0.030" thick.

z
c:::
w

11..

2. All si_gns i_nstalled on mast. arms or standards (poles)


requ1re wmdbeams. All s1gns shall be installed with
horizontal edges level. A skewed windbeam is required only when the sign is mounted within 12" of
the mast arm base (see Detaii"A").

SIGNAL STANDARD

SIGNAL HEAD
BACK PLATE

s -

II

MAST ARM BASE


BACK OF SIGN PANEL

=MORE THAN 4' - 0" BUT NOT MORE THAN 8' - 0"
3/16" RIVET {TYP.)
- 4" MAX. SPACING

X/2
SIGNAL HEAD
BACK PLATE

6"

1'- 0"

WINDBEAM
{TYP.)

MIN.

I
:
----t--l!
1:

L..__

__

3. The street name sign shall be a maximum of 36


square feet and the sign height is a maximum of 3
feet; signs larger than 36 square feet require a
special design mast arm and signal pole.

SEE NOTE 2

1'- 0"

1'- 0' MIN.


2'- 6" MAX.

BACK OF SIGN PANEL


SIGNAL STANDARD
_

DETAIL

LEVEL

TYPICAL FOR EACH CONNECTION


MAST ARM BASE
BACK OF SIGN PANEL

SIGNAL HEAD
BACK PLATE
X

=MORE THAN 8' - 0"

BACK OF SIGN PANEL


UNIVERSAL CHANNEL
CLAMP

6"

1'- 0"

1'- 0"

MIN.

1'- 0' MIN.


2'- 6" MAX.

MAST ARM

-----r--1-.=-

SIGNAL STANDARD

STEEL STRAP
LEVEL

SIGN INSTALLATION
ON SIGNAL AND
LIGHT STANDARDS
STANDARD PLAN G-30.10-02
SHEET 1 OF 2 SHEETS

BACK OF SIGN PANEL

WIND BEAM
{TYP.)

MAST ARM BASE

APPROVED FOR PUBLICATION

WINDBEAM

__
P,_a_sc=o=B=ak=o=t=ic=h,-ll_l _ _ 6120113
......

MAST ARM-MOUNTED STREET NAME SIGNS

TYPICAL MAST ARM INSTALLATION

STATE DESIGN ENGINEER

yj, Washington

DATE

Stote Department of Transportation

....1
....1

DIMENSIONS

0
0

::J

3'- 0"

9"

4'- 0"

1'- 0"

z
c:::

11..

4'

- 0" MAX

r*
iri
N

WIND BEAM

+I

ci

/~WIN DBEAM

---f---

---

--

---,...---

>-

ci

II

-- ------

SIGN PANEL

-~

iri

- - - - - - r---

ci
-

---1

--1--

---

--r-

>-

BACK OF SIGN PANEL

MOUNTING BRACKET
AND STEEL STRAP
- SEE NOTE 1

Ll'l
N

'

3/16" RIVET (TYP.)


- 4" MAX. SPACING

Ll'l
N

ci

--

LEVEL

-----

1" (TYP.)

SIGNAL OR LIGHT
STANDARD
'-........_BAG K OF SIGN PANEL

SECTION

~
'

SIGNAL OR LIGHT STANDARD

SIGNAL OR UGH T STANDARD (REFER


TO APPROVED SHOP DRAWINGS
FOR MAXIMUM A LLOWED SQUARE FOOTAGE)

f.-

'

"

SIGN INSTALLATION ON SIGNAL OR LIGHT STANDARD

I.
3'- 0"

y
2'- 6"

c
1'- 0"

a.:
~
....-

DIMENSIONS
X

.I

! lj!

D
6"

3'- 0"

3'- 0"

1'- 0"

6"

4'- 0"

2'- 6"

1'- 3"

9"

~i

!
I
LEVEL

MOUNTING BRACKET
AND STEEL STRAP
- SEE NOTE 1

!~
~

1'-----

BACK OF SIGN PANEL

SIGN INSTALLATION
ON SIGNAL AND
LIGHT STANDARDS
STANDARD PLAN G-30.10-02

~ C---j-! D-j-! D-j-! cMAST ARM-MOUNTED LANE USE SIGNS

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

NOTES
....1
....1

0
0

1. Mounting brackets with steel straps shall be a stainless steel band and
buckle system product or an approved equal. Mounting brackets shall
be one bolt, flared leg; steel straps shall be 3/4" wide and 0.030" thick.

STEEL TUBE SIGN POST

::J

z
c:::

SIGN PANEL

11..

2. Sign braces are only installed when specified in the contract.


3. Sign braces are typically necessary on large sign panels that are exposed to high winds, traffic generated wind buffeting, or when snow
thrown from plows might impact the sign.
SIGN BRACE

SIGN BRACE

4. A nylon washer shall be placed between the sign and the steel washer
when the sign face has Type Ill, IV,VIII or IX sheeting.

SIGN PANEL

MOUNTING BRACKET AND


STEEL STRAP WITH WINDBEAM
PER STANDARD PLAN G-30.10,
SHEET 2 OF 2 (TYP.)
SIGN PANEL
TIMBER SIGN POST

STEEL PIPE SIGN POST

SIGN BRACE ON STEEL TUBE

SIGN BRACE ON TIMBER POST

FIELD DRILL 5/16" DIAMETER


HOLE IN SIGN PANEL (TYP.)

FOR SIGN ATTACHMENT,


SEE DETAIL- STANDARD
PLAN G-22.1 0

SIGN PANEL
FIELD DRILL 5/16" DIAMETER HOLE
IN SIGN PANEL (TYP.)
FOR SIGN ATTACHMENT,
SEE DETAIL - STANDARD
PLAN G-24.50

1/4" DIAMETER)( 1" LONG


HEX HEAD BOLT, NUT,
AND WASHERS (TYP.)
-SEE NOTE 4

SIGN BRACE

SIGN PANEL

MOUNTING BRACKET AND STEEL STRAP


DETAIL

SIGN BRACE ON STEEL PIPE


SIGN BRACE

3/8" DIAMETER x 1 1/2" LONG


LAG SCREW AND WASHERS

1/4" DIAMETER x 1" LONG


HEX HEAD BOLT, NUT,
AND WASHERS (TYP.)
-SEE NOTE 4

STEEL TUBE SIGN POST

PLAN

PLAN

SIGN PANEL
1/4" DIAMETER)( 1" LONG
HEX HEAD BOLT, NUT,
AND WASHERS (TYP.)
-SEE NOTE 4

FOR SIGN ATTACHMENT,


SEE DETAIL -STANDARD
PLAN G-30.1 0

STEEL PIPE
SIGN POST

FIELD DRILL 5/16" DIAMETER


HOLE IN SIGN PANEL (TYP.)

SIGN BRACING
STANDARD PLAN G-50.10-01
SHEET 1 OF 2 SHEETS

SIGN BRACE

APPROVED FOR PUBLICATION


5/16" DIAMETER HEX HEAD
BOLT AND WASHERS

MOUNTING BRACKET
AND STEEL STRAP
-SEE NOTE 1

.....

STATE DESIGN ENGINEER

~ Washington State

PLAN

6120113
DATE
.
Department of Transportation

Pasco Bakotich Ill

SIGN WIDTH
....1
....1

SIGN

BRACE

DIMENSIONS

0
0

SIGN WIDTH

SIGN TYPE

::J

z
c:::

Q::c

36" OR GREATER

36" OR GREATER

SIGN WIDTH

zi-

36" OR GREATER

en(!)

!!1iii
YIELD

DIAMOND-SHAPED

..-::c

OTHERS

11..

1/3 SIGN WIDTH- 1 3/4"

1/2 SIGN WIDTH - 2 1/4"

1/2 SIGN WIDTH- 1"

4)(6 OR 6)(6
TIMBER POST

6)(8
TIMBER POST

3"DIAM.
STEEL PIPE

2 1/2" SQUARE
TUBE

5 1/2"

7 1/2"

4 3/4"

2 1/2"

en_
N W ~
;::: ::r: z

iii

::c

(.!)

Ci5

BRACE

_/

NOTE
1. For sign installations on round steel posts, see
Standard Plan G-30.1 0, sheet 2 of 2.

1-

(.!)::C
-(.!)

::c
(.!)

SIGN POST TYPE

1-

--1-

YIELD SIGN

.-

BRACE

--<

l-

en
en
w
....1

1-

(.!) ::c
Ci5 (.!)

r;-

iii

!!1
...... ::c
f----z

1-

(.!) ::c
Ci5 (.!)

"

iii
!!1
...... ::c
c----,z 1-

c:::
w
c:::

(.!)

::5

c:::

0
N
r---

(.!) ::c
Ci5 (.!)

iii
!!1
...... ::c

L,./1

0-

SMALL RECTANGULAR SIGN

LARGE RECTANGULAR SIGN

SIGN WIDTH
SIGN WIDTH

1-

::c
(.!) ......

36" OR GREATER

iii~

36" OR GREATER

:co
z z

(.!)

1-

~ ~
~
iii

(i)

TOP

ZI-

(.!)::C
-(.!)

1-

(.!)::c

::c

en iii 1~ ::c ~

Ci5 Q I-

(.!)

;::: ::c

Ci5

::C
(.!)

iii

iii

::c

(.!)

::c

(.!)

BRACE

Ci5
BRACE

BRACE
5/16" DIAM. )( 1" LONG
SLOT (TYP.)
SIDE

SIGN WIDTH

SIGN BRACE DETAIL

DIAMOND-SHAPED SIGN

2/3 SIGN WIDTH - 3 1/4"

Ci5

RAILROAD WARNING SIGN

1/3 SIGN WIDTH - 1"

SIGN WIDTH

36" OR GREATER

t
~~

TOP

Ci5 Q IN

;::: ::c

1/8" GALV. STEEL


OR S.S. STRAP

::C
(.!)

iii

1/2" DIAM. HOLE

::c

(.!)

Ci5
NO PASSING ZONE SIGN
BRACE - SEE DETAIL
5/16" DIAM. )( 1" LONG
SLOT (TYP.)

SIGN BRACING
STANDARD PLAN G-50.10-01

1/3 SIGN WIDTH


SIDE
SIGN WIDTH

NO PASSING ZONE
SIGN BRACE DETAIL

SHEET 2 OF 2 SHEETS
BRACE
APPROVED FOR PUBLICATION

NO PASSING ZONE SIGN

SCHOOL ZONE SIGN

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

SIGN BRACE PLACEMENT

NOTES
TRUSS "LOWER" HORIZONTAL
DIAGONAL (TYP.)

POST SELECTION
TOTAL SIGN AREA
I (X TIMES Y)
(FT2)

POST SIZE
O.D.

WALL

18"

0.438"

50 OR LESS

....1
....1

LlJ

Cl
Cl

0:::

50+ to 100

18"

0.438"

24"

0.375"

....1
(!)

150+ to 200

24"

0.375"

en

200+ to 250

24"

0.375"

250+ to 300

24"

0.375"

[D

300+ to 350

24"

0.438"

o t-o

350+ to 400

24"

0.500"

c3

LlJ

2.

0:::

~~

100+ to 150

[D

LlJ

::::>:::!
0 1~ Cl~

0:::
....1

TRUSS "UPPER" HORIZONTAL


DIAGONAL (TYP.)

TOP

LlJ LlJ

>
>LlJ ....1

PANEL LENGTH (4' - 3" MAX.) TO BE


0 MIN T~

::::i

CONSTANT THROUGHOUT SPAN


VERTICAL "FAR"
TRUSS DIAGONAL (TYP.)
I

VERTICAL STRUT
AT SPAN END ONLY\

0:::
LlJ
LL.

ffiUSS &:I:N ~ 0
~~

>-

\l

~~--

1" MAX. AT TOP OF POST

VERTICAL "NEAR"

~~===;~==::::;T;I:~~U=S=S=D=IA: : ;G; :O~N=A=L=(TY=P;.):~==P;;:=;)rn==::::::;;:~~~~

0.004 FT/FT FOR


SINGLE CANTILEVER

END

I
.

I
BOTTOM OF LUMINAIRE
BRACKET - WHEN SIGN
LIGHTING IS SHOWN
IN THE CONTRACT

X/2

MATERIAL SPECIFICATIONS

= 21'- 0" MAX.

ct

SIGN

ASTM A36
ASTM A 992

BOLTS, NUTS,
&WASHERS

STD. SPEC.
9-06.5(3)

PIPE, PLATE
& SHAPE
GALVANIZING

AASHTO M 111

FASTENER
GALVANIZING

SCREEN- SEE
DETAIL, SHEET 4

6. Adjust post alignment in plane normal to roadway centerline by


means of leveling nuts located below base plate to maintain upward slope in cantilever arm(s). Tighten anchor nuts above base
plate in accordance with Standard Specification 6-03.3(33).
7. Variable Message Signs (VMS) exceeding 700 lbs. and/or 200 sq. ft.
shall not be installed on cantilever structure.
8.

For electrical requirements, see Standard Plan J-75.45.

i
b

'

HAND HOLE ON SIDE


OPPOSITE OF
MAIN ROADWAY

BOTTOM OF
BASE PLATE

~ SIGN CENTERLINE MAY VARY FROM TRUSS CENTERLINE


TO PROVIDE MINIMUM VERTICAL CLEARANCE.

ELEVATION
CHORD SELECTION

AASHTO M 232

J:

SHAPES

1 1/4" CAPPED NIPPLE


- ON SIDE OPPOSITE
APPROACHING TRAFFIC

5. The design and analysis of the structures has been done in accordance with AASHTO Standard Specification for Structural Supports
for Highway Signs, Luminaires and Traffic Signals Dated 2001,
using 90 MPH wind velocity and fatigue category - I.

------------r---~-------

ASTM A36

PLATES

~~------L ___________ l-----------~

ALL TRUSS DIAGONALS AND STRUTS


SHALL BE 1 1/2" PIPE (0.145" WALL)

ASTM A36
ORASTM A 53
GRADE B,
TYPE E OR S, OR
A500 GRADE B

~)~CHORD

~ j_Tc...;J~.If:u~s=s=====~==~====~===~===F=====:========o$=o:===~

INTERIOR DIAGONAL
AT SPAN END ONLY

PIPE
(CHORDS,
DIAGONALS,
STRUTS AND
POSTS)

4. All bolt holes shall be drilled, and the diameter shall be 1/16" larger
than the nominal bolt diameter, except as noted.

ct_ POST ~r--s- VERTICAL

---------~-----------~

No post splices permitted in lower third of height, nor closer than


3' - 0" to bottom chord, except as otherwise noted. No chord shop
splices permitted in first two-thirds of the span, except as otherwise
noted. A maximum of two splices are permitted in the post. For
post or chord shop splice details, see Standard Plan G-70.10.

3. The back-up plates or rings for all full penetration welds shall be
welded continuously to the joined pieces. This can be done by
either a continuous fillet weld on the back side of the piece, or by a
continuous weld in the root of the full penetration weld.

::::> :::!z
Cl z

SUM OF SIGN FOR DOUBLE CANTILEVER

~
, ....) I

1. Vertical and horizontal clearance requirements shall be as shown on


the contract plans.

HORIZONTAL STRUTS
AT SPAN END ONLY

SIGN AREA
(X TIMES Y)
(FT2)

CHORD SIZE
NOM.
DIAM.

WALL

50 OR LESS

2"

0.154"

50+ TO 100

2"

0.218"

100+ TO 150

2 1/2"

0.203"

150+ TO 200

3"

0.216"

SINGLE CANTILEVER SIGN STRUCTURE

PERSPECTIVE

CANTILEVER
SIGN STRUCTURE
(TRUSS-TYPE)
STANDARD PLAN G-60.10-02
SHEET 1 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

PANEL LENGTH (4' - 3" MAX.) TO BE


CONSTANT THROUGHOUT SPAN

VERTICAL "FAR"
TRUSS DIAGONAL (TYP.)

Cf.

POST

....1
....1

0
0

~-----------------------~

::J

z
c:::

I
r.:
I
1:. CHORD (TYP.) I

I
I
1

I
I

LL.

_ _j_

I
I
I

~c::,:.o:::~;,~~~~~~~~~~~~~~~~~~~~~~~

io

'

:::!:

:I:b

X
X/2

=21'- 0" MAX.

HAND HOLE ON SIDE


AWAY FROM TRAFFIC

PERSPECTIVE

ct.
SIGN
SCREEN- SEE
DETAIL, SHEET 4

<2)

BOTTOM OF
BASE PLATE

BASE
ELEVATION
SIGN CENTERLINE MAY VARY FROM TRUSS CENTERLINE
TO PROVIDE MINIMUM VERTICAL CLEARANCE.

ELEVATION

DOUBLE CANTILEVER SIGN STRUCTURE

CANTILEVER
SIGN STRUCTURE
(TRUSS-TYPE)
STANDARD PLAN G-60.10-02
SHEET 2 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


------~s=~~T~ED=E~SIG~N~E~NG~IN=EE=R~----

6110113
DATE

~
~ Washington State Department of Transportation

3/4" MAX.

HEMISPHERICAL POST FINIAL,


1/8" MIN. THICKNESS. INSTALL
AFTER GALVANIZING

=--:........:.:~~

3/8" ALLEN HOLLOW SET SCREW


WITH DOG POINT (TYP.)
(CORROSION RESISTANT METAL
OR COATING) AT go INTERVALS

DRILL AND TAP


WALL FOR 3/8" \
ALLEN SET SCREW

....1
....1

1/8" PLATE MIN.


\

SECTION THROUGH
FINIAL AND POST

ELEVATION

LlJ

ROTATED go TO
SHOW CUTOUT

c:::
LL.

3/8" ALLEN HOLLOW


SET SCREW
AT 180" INTERVALS

SPAN END - SIDE

LlJ

::::i

5/16" x 112" SLOT FOR


3/8" ALLEN SET SCREW

CUT HOLE IN POST


FOR WIDE FLANGE,
1/8" MAX. CLEARANCE
ALL AROUND

Cl
Cl

STANDARD GALVANIZED STEEL SCREW CAP,


OR AN APPROVED ALTERNATE. INSTALL AFTER
GALVANIZING TRUSS

15/16" DIAM. HOLE (TYP.)


(OMIT HOLES IN
OPPOSITE FLANGE FOR
SINGLE CANTILEVER)

It

CHORD

W10x4g

SPAN END - END

FINIAL BRACKET

3/4" DIAM. HOLE IN


CHORD AT EACH END
OF ALL DIAGONAL
CHORDS AND STRUTS

OPPOSITE HAND SHOWN


FOR CLARITY

1/4" PLATE
10" X 10"

SPAN
END

F======~
'

DIAGONAL CONNECTION DETAIL


8" DIAM.
BOLT CIRCLE

TYPICAL OF ALL DIAGONALS

END OF
CHORD

CHORD
100% MT
SEE WELD
DETAIL "D"

DIAGONALS

ELEVATION
ISOMETRIC

SYMMETRICAL
ABOUT POST It

2 1/2

BASE

BASE - SIDE

BACK-UP RING

~ 3" DIAM. PIPE (t =0.300) SPLICE WITH 3" DIAM.

ct
DETAIL "D"

PIPE (t = 0.216) (SEE CHORD SELECTION TABLE)


2 1/2" DIAM. PIPE (t = 0.276) SPLICE WITH 2 1/2" DIAM.
PIPE (t = 0.203) (SEE CHORD SELECTION TABLE)
g"

1/2" DIAM. HOLES


AS CLOSE TO WELD
AS POSSIBLE TO
FACILITATE GALVANIZING

PIPE WALL

3/16

3/4" FLANGE
PLATE

7/8" DIAM. BOLTS x 2 1/2" LONG


(STD. SPEC. g-06.5 (3),
HEAVY DUTY NUT AND 2 WASHERS (TYP.)
-INSTALL BOLTS WITH HEAD TOWARD CHORD

1'- 4 1/2"

4 1/2"

"I

ct

CHORD

TOP

CHORD TO POST
CONNECTION DETAIL

CANTILEVER
SIGN STRUCTURE
(TRUSS-TYPE)
STANDARD PLAN G-60.10-02

8" DIAM. BOLT CIRCLE

3/4" R. (TYP.)

15/16" DIAM. HOLES


FOR FOUR, 7/8" DIAM. BOLTS
(ASTM A 325)

BASE-TOP

SECTION

TYPICAL TRUSS DETAILS


ENDS OF DIAGONALS SHALL BE CUT TO FIT
NEATLY AGAINST CHORDS

SHEET 3 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

yj, Washington

6110113
DATE

Stote Department of Transportation

1' - 4 1/2"

~POST

.-------&

REMOVABLE RAIN TIGHT


HAND HOLE COVER WITH GASKET
- FASTEN WITH TWO STAINLESS STEEL
(ASTM F 593) SCREWS

""' \

....1
....1

0
0

1' - 4 1/2"

~
~

"""
.....'

_\

::::i

0::

11..

DRILL AND TAP FOR 1/4" DIAMETER CAP


SCREW- SPACING APPROX. 9" O.C.
ASTM F 593, W/ S.S. WASHER
LIBERALLY COAT THE THREADS
WITH ANTI-SEIZE COMPOUND
(TYP.)

"""'

.....

/
2'- 6" DIAM.
BOLT CIRCLE

TOP OF BASE

WELDED GALV. CLOTH


1/16" x 7/16" SQ. WRAP
AROUND BASE PLATE
WITH 3" MIN. LAP

0
I"

v
_/

2" DIAM. HOLES


FOR ANCHOR BOLTS
(TYP.)

HOLE IN POST BASE


(HOLE DIAM. =POST I. D.- 2")

rAI"'

ANCHOR BOLT (TYP.)

TOP OF
FOUNDATION

SCREEN DETAIL

PIPE WALL

TOP

100% UT
BACK-UP RING

100% UT
SEE WELD
DETAIL "G"
PIPE O.D.

1/2" DIAM. STEEL BOLT.


1 1/2" LONG, WITH WASHER

AND NUT FOR GROUND

DETAIL"G"

INSIDE EDGES SHALL BE


ROUND AND SMOOTH
ALL AROUND

3/16

SECTION

BASE WELD DETAIL

24"
24"
18"
18"

O.D.
O.D.
O.D.
O.D.

VIEW0

PIPE (t = 0.969) SPLICE WITH


UPPER POST (SEE POST SELECTION TABLE)
PIPE (t = 0.750) SPLICE WITH
UPPER POST (SEE POST SELECTION TABLE)

POST BASE DETAILS

CANTILEVER
SIGN STRUCTURE
(TRUSS-TYPE)
STANDARD PLAN G-60.10-02
SHEET 4 OF 4 SHEETS
APPROVED FOR PUBLICATION

6110113
DATE
.
Department of Transportation

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

yj, Washington

Stote

CONDUIT COUPLING- INSTALL FLUSH WITH TOP


OF FOUNDATION (DO NOT GLUE PVC STUBOUT)

GROUNDING CONDUCTOR SHALL BE


NON-INSULATED #4 AWG STANDED
COPPER- PROVIDE 3'- 0" SLACK
(ROUTE TO GROUNDING STUD)

ANCHOR ROD - 1 3/4" DIAM. x 4'- 4" LONG,


THREADED 8" MIN. EACH END; W/2 WASHERS
& 4 HEAVY HEX NUTS- GALVANIZE EXPOSED
ANCHOR ROD END FOR 1'- 0" MIN.

PROVIDE SCREEN AROUND BASE - SEE


SCREEN DETAIL, STANDARD PLAN G-60.10,
SHEET4

~=~#[~)~

Uc

Zz

4'-0"

~=>

1'- 4"

3/4" CHAMFER
(TYP.)

<(0

wC:::
__.<(

1'- 4"

(.)...J

~<i!

~~~~~~~~~~~
FINISH
GROUND LINE

FINISH
GROUND LINE
0
0

en

0
....

en

---------------------

a.
<(

(.)

(.)

w
1-w

a:::

1" STEEL CONDUIT


OR AS PER CONTRACT
-WHEN REQUIRED,
CAP EACH END

(.)

(i)#5

I()

'1:1::

'

"'"

@#9(TYP.)

~
en

<i!
=>
a
w

'

;...'

"'"
ANCHOR PLATE (TYP.)
-SEE DETAIL, SHEET 2

....

@#5(TYP.)

(.)

G)#4SPIRAL
G)#4 (TYP.)
STEEL CONDUIT

ANCHOR PLATE

CONSTRUCTION JOINT
WI ROUGHENED SURFACE

c
w

....1

Ill

(.)

en

Ill

....1
....1

II

VIEW0

<(

a.
w
c

a.
0
0
0

....
en
en

:5(.)
w
1-w
a:::

(.)

(.)

~a:::

FOUNDATION
200 SF OR LESS 200 SF - 400 SF
TYPE

1--

(.)

ALLOWABLE LATERAL
BEARING PRESSURE
(PSF)

13'- 0"

18'- 0"

1500 AND UP

16'- 0"

22'- 0"

1000 - 1499

1. See Standard Specification 8-21. 3(9)


for construction requirements.

_....J

4'- 0"

1--

c
z
<(

iiS

en cw
Ill
c a:::
w =>
a::: 1-5 en
aw i5
z
a::: =>
1-!:!: en
c5 z
z

(.)

TOTAL SIGN AREA

li:

w a:::
1-- i5
w
a:::

VALUES OF Z

a:0

1--

NOTES

12-@#9

:5a.

w
w

TOP

a:
b

;...'
I
....1

::!:

Ill

!;;:

a:::

=>
~ w
a: 1--w
en ....1
.... a.
'1:1::

1--

...---..---_

't.'.
~

".

, A. .

' lJ: .
~

".

, A. .

t.
~

".

~
.

." .
.

tJ: .

""

II>

z
Q.

v,s-

.. ./

..

tJ: .

y/>~1>.>.>
. .
. .

::!:
0

(.)

2. Use a template to locate and secure bolts in


place during foundation installation.

..

~ ____. ___...

#9(TYP.)

(.)

CLAMP STEEL REINFORCING


BAR WITH CONNECTOR
SUITABLE FOR USE
EMBEDDED IN CONCRETE

G)#4

CANTILEVER SIGN
STRUCTURE (TRUSS-TYPE)
FOUNDAT(ON TYPE 1
STANDARD PLAN G-60.20-01

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ISOMETRIC
SIDE

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

2' - 6" BOLT CIRCLE

BAR LIST

2" DIAM. HOLE FOR


ANCHOR BOLT (TYP.)
1/2" PLATE (ASTM A 36)
(NO GALVANIZING REQUIRED)

MARK

LOCATION

QTY.

LENGTH

SIZE

TYPE

CD

CAP VERTICAL

3'- 10"

#4

STR.

CAP HOOPS

15'- 9"

#5
#9

CD

SHAFT VERTICAL

12

"Z"MINUS
CLEARANCES

SHAFT SPIRAL

AS REQUIRED

#4

CAP TOP

10'- 10"

#5

STR.

BENDING DIAGRAM
(ALL DIMENSIONS ARE OUT TO OUT)

ANCHOR PLATE DETAIL

,~u

(TYP.)

a~~
1,!-ENGTf-!1

SQUARE

CD

n
d

SQUARE

MAY BE FIELD BENT (TYP.)

SPI~~~ !" L .,

''"'1:\'"

SHOP WELO::c OR
LJ2

r
j

S(E): <;;: L

<SHOP

FIELD WELD OR

WELD

SEE TABLE FOR WELD DIMENSIONS

SPIRAL WELDED LAP SPLICE DETAIL

SPIRAL LAP SPLICE DETAIL

WELDING SHALL MEET THE REQUIREMENTS OF STD. SPEC. 6-02.3(24)E


FOR WELD DIMENSIONS- SEE TABLE BELOW

COLUMN AND SHAFT SPIRAL OPTIONS


DEFORMED BAR
AASHTO M 31
GRADE60

PLAIN STEEL BAR


AASHTO M 31
GRADE60

COLD DRAWN WIRE


AASHTO M 32

DEFORMED WIRE
AASHTO M 225

MATERIAL SPECIFICATIONS
SHAFT
CONCRETE

CLASS4000P

ALL OTHER
CONCRETE

CLASS 4000

STEEL
REINF. BAR

AASHTO M 31
GRADE 60

ANCHOR RODS

ASTM F 1554
GRADE 105

ANCHOR NUTS

AASHTO M291

WELD DIMENSIONS (INCHES)

#4

1/2" DIAM.

W20

D20

1/4

1/8

ANCHOR
WASHERS

AASHTO M 293

#5

5/8" DIAM.

W31

D31

5/16

3/16

ANCHORAGE
GALVANIZING

AASHTO M 232

#6

3/4" DIAM.

W44

D44

3/8

3/16

ANCHOR
PLATE

ASTMA36

CANTILEVER SIGN
STRUCTURE (TRUSS-TYPE)
FOUNDAT(ON TYPE 1
STANDARD PLAN G-60.20-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

0
0:::

ANCHOR PLATE

11..

G)#10TYP.

GROUNDING CONDUCTOR- ROUTE


TO GROUNDING STUD (SEE NOTE 2)

3"CLR.

@#5TYP.

I" (TYP.)

ANCHOR PLATE (TYP.)- SEE DETAIL,


STANDARD PLAN G-60.20, SHEET 2

::J

NOTES

~
z
~

1" STEEL CONDUIT (GALV.)


-OR AS SHOWN IN CONTRACT

1. See Standard Specification


8-21. 3(9} for construction
requirements.

CD #6TYP.

#5
STRAIGHT

PERPENDICULAR
TO ROADWAY
CENTERLINE

2. Grounding Conductor shall


be non-insulated #4 AWG
stranded copper. Provide
a 3'- 0" min. slack.
SIDE
ON SLOPED GRADE
(SHOWN AT REDUCED SCALE)

GROUNDING CONDUCTOR- ROUTE


TO GROUNDING STUD (SEE NOTE 2)

TOP
CONDUIT COUPLING -INSTALL FLUSH WITH TOP
OF FOUNDATION (DO NOT GLUE PVC STUBOUT)

3'- 3"

GROUNDING CONDUCTOR- ROUTE


TO GROUNDING STUD (SEE NOTE 2)

CONDUIT COUPLING - INSTALL FLUSH WITH TOP


OF FOUNDATION (DO NOT GLUE PVC STUBOUT)

1" STEEL CONDUIT (GALV.)- WHEN


REQUIRED -CAP EACH END

3'- 3"

~~

FOR LEVEL GRADE

ANCHOR ROD - 1 3/4" DIAM. x 4' - 4"


THREADED 8" MIN. EACH END; W/2 WASHERS
& 4 HEAVY HEX NUTS- GALVANIZE EXPOSED
ANCHOR ROD END FOR 1'- 0" MIN.

PROVIDE SCREEN AROUND BASE -SEE


SCREEN DETAIL, STD. PLAN G-60.10,
SHEET4
3/4" CHAMFER (TYP.)

b
;...'

#5
FOR SLOPED GRADE

ISOMETRIC

#5TYP.

....1

fil

ANCHOR PLATE (TYP.)- SEE DETAIL,


STANDARD PLAN G-60.20 SHEET 2

w
w

en

C)

u
<(
CLAMP STEEL REINFORCING
BAR WITH CONNECTOR
SUITABLE FOR USE
EMBEDDED IN CONCRETE

a.

'
N

::::>

1-

en

:::!:
;...'

@)

en
z

II

a.
w

II

>-

CANTILEVER SIGN
STRUCTURE (TRUSS-TYPE)
FOUNDATION TYPES 2 & 3
STANDARD PLAN G-60.30-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

CD

#6
2 SPACES@ 13"
2' -2"

CD

10'- 0"

SIDE

#6
2 SPACES@ 13"
2' -2"

Pasco Bakotich Ill

3'- 6"

END

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

en
z
w
w

0::
ID
....1
....1

iii

BAR LIST - TYPES 2 AND 3

VALUES OF Z

TOTAL SIGN AREA


MARK

LOCATION

TOTAL SIGN AREA


FOUNDATION
TYPE

+200 SF
-400 SF

200SF
OR LESS
QTY.

SIZE

QTY.

SIZE

CD

PEDESTAL HOOP

#4

#4

FOUNDATION WALL TIES

#5

#5

FOUNDATION VERTICALS

14

#6

14

#6

CD

PEDESTAL VERTICALS

16

#10

16

#10

FOUNDATION WALL HORIZONTALS


AT SLOPE

#5

#5

FOUNDATION WALL HORIZONTALS

VARIES
SEE PLANS

#5

VARIES
SEE PLANS

#5

ALLOWABLE LATERAL
BEARING PRESSURE
(PSF)

200 SF OR LESS

200 SF - 400 SF

TYPE2

9'- 0"

11'- 0"

2500 OR GREATER

TYPE3

11'- 0"

13'- 6"

NOT LESS
THAN 1500

BENDING DIAGRAM
MATERIAL SPECIFICATIONS

,,,\~
(TV~~~

~-

SQUARE
VARIES

~]

CONCRETE

CLASS 4000P

STEEL
REINF. BAR

AASHTO M 31
GRADE60

ANCHOR RODS

ASTM F 1554
GRADE 105

ANCHOR NUTS

AASHTO M 291

ANCHOR
WASHERS

AASHTO M 293

ANCHORAGE
GALVANIZING

AASHTO M 232

ANCHOR
PLATE

ASTMA36

CANTILEVER SIGN
STRUCTURE (TRUSS-TYPE)
FOUNDATION TYPES 2 & 3
STANDARD PLAN G-60.30-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


STATE DESIGN ENGINEER

06-27-11
DATE

.....
f
.
. . . Washington State Department o Transportation

NOTES
....1
....1

0
0

1.

Horizontal and vertical clearance requirements shall


be as shown in Contract Plans.

2.

Horizontal diagonals must join chords where vertical


diagonals connect (panel points).

3.

Interior diagonals shall be placed at panel points,


40' maximum spacing. Locate symmetrically about
centerline of span if possible. An interior diagonal
is not required at span ends.

4.

No post splices permitted in lower third of height,


nor closer than 3' - 0" to bottom of chord. No
chord shop splices permitted in middle third of span.
Maximum of one splice in each end post.

5.

For electrical requirements See Standard Plan J-75.45.

::::i

0:::

11..

0
0

"UPPER" HORIZONTAL
DIAGONAL (TYP.)

SEE CHORD TO END POST CONNECTION TYPE Q


SEE CHORD TO END POST CONNECTION TYPE R

~ TOP END TRUSS DIAGONAL JOINS END POSTS AT


CHORDS WHERE VERTICAL AND HORIZONTAL
DIAGONALS CONNECT
INTERIOR
DIAGONAL (TYP.)

TOP I

~ SYMMETRICAL ABOUT ~ SPAN

I
NUMBER OF PANELS VARIES.
ALTERNATE DIAGONALS TO BE
PARALLEL. DIMENSION C
NOT TO EXCEED 1.25 TIMES D

(EXCEPT FRAMING WITH ODD


NUMBER OF PANELS)

, - - - - - - - - - - - - - - - - - - - - - - - - - - EQUAL ELEVATIONS
SPAN LENGTH S ( ~ TO ~ OF END POSTS)
PANEL POINTS (TYP.)
- SEE NOTES 2 AND 3

INTERIOR
DIAGONAL (TYP.)

"FAR" VERTICAL
DIAGONAL (TYP.)

"NEAR" VERTICAL
DIAGONAL (TYP.)

~OF SIGNS
AND TRUSS
1 1/4" CAPPED NIPPLE
- ON SIDE OPPOSITE
APPROACHING TRAFFIC

'----

~r ~ ~ ~ g~----

END POST
END TRUSS
DIAGONAL (TYP.)

'

I '-----GANEL LENGTH

END TRUSS
STRUT

p TO BE CONSTANT THROUGHOUT
SPAN AND NOT TO EXCEED D + 2".

BOTTOM OF LUMINAIRE BRACKET / - - - WHEN SIGN LIGHTING IS SHOWN


~
00
IN THE CONTRACT (TYP.)

-'

POST BASE AND SCREEN


- SEE DETAILS, SHEET 4

~ ~ o:::

i1j
_.

u.. u.. 0:::


:z:O!i)~
:!l!zZ~

....1

&,oo

()
<C

'

5::2

r-~~L_

D.. 0:::

~ ~!n~
w
wz
> (!)
J: ::I

____________________________________

SIGN BRIDGE FOUNDATION


- SEE STD. PLAN G-70.20 & G-70.30

-0~

'

BASE ELEVATION
(TYP.)

_L_I-------~-

Y1 = HEIGHT OF SHALLOWEST SIGN ON STRUCTURE, D + 1'- 0" MIN.

END

Y2 =HEIGHT OF ANY SIGN WITH HEIGHT GREATER THAN Y 1 .

ELEVATION
MATERIAL SPECIFICATIONS
PIPE
(CHORDS,
DIAGONALS,
STRUTS AND
POSTS)

ASTM A36
ORASTM A 53
GRADE B,
TYPE E OR S, OR
A500 GRADE B

PLATES

ASTM A36

SHAPES

ASTM A36
ASTM A 992

BOLTS, NUTS,
&WASHERS

STD. SPEC.
9-06.5(3)

PIPE, PLATE
& SHAPE
GALVANIZING
FASTENER
GALVANIZING

AASHTO M 111

AASHTO M 232

STRUCTURE DIMENSIONS
TOP AND
BOTTOM
CHORDS

DIAGONALS

DIMENSION
D

END TRUSS
POSTS

END TRUSS
STRUTS AND
DIAGONALS

TOTAL SIGN
AREA (MAX.)
(SQ. FT.)

60' OR LESS

4'- 0"

3" X .216"

1 1/4" X .140"

10" X .279"

2 1/2" X .203"

384

61' to 90'

5'- 0"

4" X .237"

2" X .154"

10" X .279"

2 1/2" X .203"

624

91' to 120'

6'- 0"

5" X .258"

2" X .154"

10" X .307"

3" X .216"

864

121' to 150'

7'- 0"

6" X .280"

2 1/2" X .203"

10" X .365"

3 1/2" X .226"

1104

SPAN LENGTH

ALL MEMBERS ARE PIPE. VALUES SHOWN ARE NOMINAL PIPE SIZE AND WALL THICKNESS.

SIGN BRIDGE
(TRUSS-TYPE)
STANDARD PLAN G-70.10-02
SHEET 1 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

PERSPECTIVE

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

4 5/8"

HEMISPHERICAL POST FINIAL,


1/8" MIN. THICKNESS. INSTALL
AFTER GALVANIZING

::: 3 1/8"

DRILL PER FIELD MEASUREMENT


OF SPAN BETWEEN
COMPLETED FOUNDATIONS

{t_ HORIZONTAL DIAGONAL


HORIZONTAL DIAGONAL CONNECTION WHEN ALTERNATE
JOINT DETAIL IS USED
- SEE DETAIL, SHEET 3

5" R.
3/8" ALLEN HOLLOW SET SCREW
WITH DOG POINT (TYP.)
(CORROSION RESISTANT METAL
OR COATING) AT go INTERVALS

PLATE1/8" MIN.
'

ELEVATION

\ _ DRILL AND TAP


WALL FOR 3/8"
ALLEN SET SCREW

FABRICATE FROM
W6x25

5/16" X 1/2"
SLOT FOR
3/8" ALLEN
SET SCREW

FINIAL DETAIL
....1
....1

8 5/8"

TOP

0
0

::::i

FINIAL BRACKET

SECTION THROUGH
FINIAL AND POST

0::

11..

0
0::
(;.10
J:
()

FABRICATE FROM

W8x40

CONNECTION DATA

ELEVATION
112" DIAM. STEEL BOLT.
1 112" LONG, WITH WASHER
AND NUT FOR GROUND

3/16

ROUND AND SMOOTH


INSIDE EDGES

SPAN
LENGTH

60' OR LESS

2 3/8"

1 5/8"

61' TO 90'

2 7/8"

2 1/8"

91' TO 120'

3 3/8"

2 5/8"

121' TO 150'

HAND HOLE FRAME

BOLT
DIAMETER

7/8"0

4 1/16" 3 1/4"

INSTALL BOLTS WITH HEAD UPWARD.


EXCLUDE BOLT THREADING FROM GRIP.

REMOVABLE RAINTIGHT HAND


HOLE COVER WITH GASKET
- FASTEN WITH TWO STAINLESS
STEEL (ASTM F 593) SCREWS

TOP

4"

END POST

{t_ 15/16" DIAM.

HOLE (TYP.)

CHORD
OUTSIDE
DIAMETER

DRILL AND TAP FOR


1" DIAM. STANDARD
GALVANIZED STEEL
SQUARE HEAD PLUG
-INSTALL PLUG AFTER
GALVANIZING TRUSS

TOP

SIGN BRIDGE
(TRUSS-TYPE)

CHORD

ELEVATION
(COVER NOT SHOWN FOR CLARITY)

HAND HOLE DETAIL

STANDARD PLAN G-70.10-02


ELEVATION

VIEW0

SHEET 2 OF 4 SHEETS
APPROVED FOR PUBLICATION

CHORD TO END POST CONNECTION TYPE Q


USED WHERE NO DIAGONALS CONNECT
DETAILS NOT SHOWN ARE SAME AS CHORD TO END POST CONNECTION TYPE R,
OMITIING THE 3/4" PLATE STIFFENER ON THE TEE MEMBER.

CHORD TO END POST CONNECTION TYPE R


USED WHERE DIAGONALS CONNECT

6110113
DATE
.
Department of Transportation

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

yj, Washington

Stote

DRILLED HOLE IN CHORD AT EACH DIAGONAL


AND STRUT SHALL BE 1" DIAMETER FOR
SPANS OVER 60' - FOR SPANS 60' OR
LESS, DIAMETER SHALL BE 3/4"

ct.

3" SLOT IN HORIZONTAL


DIAGONAL FOR PLATE 3/8"

INTERIOR DIAGONAL
-WHERE REQUIRED

INTERIOR
DIAGONAL

I
I

INTERIOR DIAGONAL

....1
....1

c
c

::::i

0::

3/4" MAX.

L1..

SPAN
LENGTH
S{FT.)

ELEVATION

SECTION

ENDS OF DIAGONALS SHALL BE CUT TO FIT NEATLY


AGAINST CHORD OR POST. FILLET WELD SIZE TO BE
DIAGONAL TUBE OR PIPE THICKNESS PLUS 1/16".

ALTERNATE JOINT DATA

CHORD SHOWN - END POST SIMILAR

ALTERNATE JOINT DETAIL


SPAN
LENGTH

1/4" BACKING PLATE

BOLTQ
DIAMETER

40

1/2

50

3/4

60
61

7/8

7/8

70

TOP

TYPICAL JOINT DETAIL

L:::..
{IN.)

NOT FOR CONNECTIONS BETWEEN


VERTICAL DIAGONALS AND CHORDS

80

1 1/4

90
91

1 1/2

100

1 5/8

1 3/8

110

120

2 3/8

60' OR LESS

2 1/2"

1 1/4"

3/4"

121

2 1/8

61' TO 90'

3"

1 1/2"

7/8"

130

2 1/2

91' TO 120'

3"

1 1/2"

7/8"

140

2 7/8

121' TO 150'

3 1/2"

1 3/4"

1"

150

3 3/8

FOR SPAN LENGTHS NOT LISTED,


INTERPOLATE VALUES OF 6..
INTERIOR DIAGONAL
WHEN REQUIRED
{SEE TRUSS ELEVATION)
3/4"

~45"

INTERIOR DIAGONAL SHALL


BE SLOTTED FOR GUSSET

DEAD LOAD CAMBER


3/16" GUSSET PLATE

FOR CHORDS OVER 114" THICK


1" R.

{SQUARE FOR 1/4" OR LESS)

FABRICATE TRUSS WITH CHORDS


CURVED TO PROVIDE CAMBER.
DO NOT CAMBER BY USING SHIMS BETWEEN CHORDS AT SPLICES.

DIMENSION SHALL EQUAL CHORD THICKNESS


OR 1/4", WHICHEVER IS LESS.

END POST OR CHORD SHOP SPLICE


BOLTK

NO POST SPLICES PERMITTED IN LOWER THIRD OF HEIGHT,


NOR CLOSER THAN 3' - 0" TO BOTTOM OF CHORD. NO CHORD
SHOP SPLICES PERMITTED IN MIDDLE THIRD OF SPAN.
MAXIMUM OF ONE SPLICE IN EACH END POST.

F BOLT CIRCLE
DIAMETER OF HOLE IN
FLANGE 1/16" LARGER THAN
CHORD OUTSIDE DIAMETER

TOP

SECTION

3/16" GUSSET PLATE

SIGN BRIDGE
(TRUSS-TYPE)

CHORD FIELD SPLICE DATA


SPAN
LENGTH

0
STANDARD PLAN G-70.10-02

BOLT K
DIAMETER

SHEET 3 OF 4 SHEETS
APPROVED FOR PUBLICATION

60' OR LESS
61' TO 90'

6"

3/4"

1/2"

7"

7/8"

5/8"

CHORD FIELD SPLICE

91' TO 120'
121' TO 150'

8 1/2"
9 1/2"

1"
1 1/4"

3/4"
7/8"

{NO CHORD FIELD SPLICE PERMITTED IN MIDDLE THIRD OF SPAN LENGTH)

3/16" SHIMS ARE REQUIRED AT THE REMAINING TWO


CHORD JOINTS WHEN INTERIOR DIAGONAL IS INSTALLED.

Pasco Bakotich Ill


6110113
----------------------STATE DESIGN ENGINEER
DATE

...... Washington
yj,

Stote Department of Transportation

....1
....1

0
0

::::i

0:::

11..

I.
......
......

<

----

......
......

11"

-~

11"

DRILL AND TAP FOR 1/4" DIAMETER CAP


SCREW- SPACING APPROX. 9" O.C.
ASTM F 593, W/ S.S. WASHER. LIBERALLY
COAT THE THREADS WITH ANTISEIZE COMPOUND
(TYP.)

.I
BASE PLATE HOLE=
8" DIAM .

1'- 9" BOLT CIRCLE

v------

ANCHOR BOLT

TOP OF BASE

-,--

POST

rAII!

tl
I~

1/

1 1/2" DIAM. HOLE FOR


ANCHOR BOLT (TYP.)

TOP OF
FOUNDATION

~_/

WELDED GALV. CLOT


1/16" x 7/16" SQ. WRA
AROUND BASE PLATE
WITH 3" MIN. LA p

SCREEN DETAIL

TOP

w
....1
0
(:)JJ:

z<(
J:

'
io

]OR ROD (TYP.)

'

1/4" BACK-UP
BAR

.....

SECTION

TOP OF
FOUNDATION

SIGN BRIDGE
(TRUSS-TYPE)
VIEW0

STANDARD PLAN G-70.10-02


SHEET 4 OF 4 SHEETS
APPROVED FOR PUBLICATION

POST BASE DETAILS


BASE WELD DETAIL

Pasco Bakotich Ill


.....

STATE DESIGN ENGINEER

yj, Washington

6110113
DATE

Stote Department of Transportation

MATERIAL SPECIFICATIONS

....1
....1

LlJ

0
0

SHAFT
CONCRETE

ALL OTHER
CONCRETE

CLASS 4000

STEEL
REINF. BAR

AASHTO M 31
GRADE60

ANCHOR RODS

ASTM F 1554
GRADE 105

ANCHOR NUTS

AASHTO M 291

::::i

c:::

LlJ
LL.

1 1/4" RIGID GALV. STEEL CONDUIT


-TO BE INSTALLED WHERE DIRECTED
BY THE ENGINEER

CLASS 4000P

i -

AASHTO M 293

ANCHORAGE
GALVANIZING

AASHTO M 232

ANCHOR
PLATE

ASTMA36

1'- 9" DIAM.


BOLT CIRCLE (TYP.)

8" (TYP.)
1 1/16" DIAM. HOLE (TYP.)

1' - 3" DIAM.


NOTCH AS REQUIRED TO
CLEAR SHAFT REINFORCEMENT
WHEN D 4' - 0"

@(TYP.)

3/4" CHAMFER

ANCHOR
WASHERS

1' 6"

LAP SPLICE
DETAIL

SYMM. AB'T t_
EXCEPT CONDUIT

45 " (TYP.)
1'- 9" DIAM.
BOLT CIRCLE

TOP
GROUNDING CONDUCTOR SHALL BE
NON-INSULATED #4 AWG STRANDED
COPPER - PROVIDE 3' - 0" SLACK
(ROUTE TO GROUNDING STUD)

ANCHOR PLATE DETAIL

~ CASE THE EXCAVATION AND


PLACE USING TREMIE METHOD
WHEN WATER IS PRESENT

1/2" X 21" X 21"

ANCHOR ROD- 1" x 2'- 9"


THREADED 8" MIN. EACH END;
W/ 2 WASHERS AND
6 HEAVY HEX NUTS

CONDUIT COUPLING - INSTALL FLUSH WITH TOP


OF FOUNDATION (DO NOT GLUE PVC STUBOUT)

LEVEL

FINISH
GROUND LINE
ALLOWABLE
LATERAL BEARING
PRESSURE
(PSF)

TABLE
SPAN LENGTH

(TYP.)

FINISH
GROUND LINE

VARIABLES

DIMENSION-

60' OR LESS

61' TO 90'

4'- 0"

5'- 0"

6'- 0"

7'- 0"

91' TO 120' 121' TO 150'

BAR SPACES-

10

SHAFT DEPTH -

11'- 6"

13'- 6"

15'- 0"

16'- 6"

I-

c:::

<(
LlJ

2500 OR BETTER

LlJ

....1
....1

<(

::c
(/)

BAR LIST

LlJ

60' OR LESS

61' TO 90'

~
!;) ::!:
z

....1

LlJ
LlJ

;....

::c
~ I~
LlJ

(/)

c::: ....1
z iS
~

<..>

91' TO 120'

121' TO 150'

<..>

END

LlJ

tii t;
c:::

SPAN LENGTH
LOCATION

ANCHOR PLATE (TYP.)


-SEE DETAIL

::c

MARK

CONSTRUCTION JOINT W/
5 1/2" X 1 5/8" X 2'- 0"
SHEAR KEY

II

::c

ii:

I-

a.

(/)

LlJ

QTY.

SIZE

QTY.

SIZE

QTY.

SIZE

QTY.

SIZE

11

14

11

18

11

23

11

CD
0

SHAFT - VERTICAL
SHAFT - SPIRAL

CAP - TOP AND BOTTOM

10

12

CD

CAP-SIDES

CAP-HOOPS

14

22

CLAMP STEEL
REINFORCING BAR
WITH CONNECTOR
SUITABLE FOR
USE EMBEDDED
IN CONCRETE

BENDING DIAGRAM

ELEVATION

SIGN BRIDGE (TRUSS-TYPE)


FOUNDATION TYPE 1

FOUNDATION TYPE 1

STANDARD PLAN G-70.20-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ISOMETRIC
(ALL DIMENSIONS ARE OUT TO OUT)
2" RADIUS, UNLESS OTHERWISE NOTED

~ DETERMINE LENGTH FROM PLANS

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

MATERIAL SPECIFICATIONS

....1
....1

3/4" CHAMFER

c
c

CONCRETE

CLASS4000P

STEEL
REINF. BAR

AASHTO M 31
GRADE 60

ANCHOR RODS

ASTM F 1554
GRADE 105

ANCHOR NUTS

AASHTO M 291

ANCHOR
WASHERS

AASHTO M 293

ANCHORAGE
GALVANIZING

AASHTO M 232

0::

L1..

ANCHOR
PLATE

1' - 3" DIAM.

1 1/4" RIGID GALV. STEEL CONDUIT


-TO BE INSTALLED WHERE DIRECTED
BY THE ENGINEER

::::i

1' -9" DIAM.


BOLT CIRCLE (TYP.)

1'- 9" DIAM.


BOLT CIRCLE

GROUNDING CONDUCTOR SHALL BE NON-INSULATED


#4 AWG STRANDED COPPER- PROVIDE A 3'- 0" SLACK
(ROUTE TO GROUNDING STUD)
CONDUIT COUPLING - INSTALL FLUSH WITH
TOP OF BARRIER (DO NOT GLUE PVC STUBOUT)

ASTMA36

SYMM. AB'T

ANCHOR PLATE DETAIL

ct, ~
'1- 0"

N EQUAL

SPAN LENGTH
VARIABLES
61' TO 90'

DIMENSION - D

4'- 0"

5'- 0"

6'- 0"

7'- 0"

BAR SPACES - N

10

5'- 6"

6'- 6"

7'- 6"

8'- 6"

2500 OR BETTER

7'- 0"

8'- 6"

10'- 0"

11'- 6"

1500-2499

TYPE

ANCHOR PLATE (TYP.)


-SEE DETAIL

""
1'- 0" (TYP.)

(.!)

Ill

en

en

SPAN LENGTH

~w

ca.
z~

MARK

LOCATION

60' OR LESS

61' TO 90'

91' TO 120'

:::2:

120' TO 150'

CLAMP STEEL
REINFORCING BAR
WITH CONNECTOR
SUITABLE FOR USE
EMBEDDED IN
CONCRETE

:::J

QTY.

L1..

2
3
4
5
6

2AND3

7
2
3

8
8

CAP-TOP
CAP-SIDES
CAP-HOOPS
CAP- BOTTOM
FND. WALL -VERTICAL
FND. WALL- TIES
FND. WALL- HORIZONTAL
FND. WALL- HORIZONTAL
FND. WALL- HORIZONTAL

SIZE

4
14
6
8
30
8
4
8
10

6
4
4
6
6
5
5
5
5

QTY.

SIZE

QTY.

SIZE

QTY.

SIZE

4
16
8
8
42
8
4
8
12

5
18
14
10
42
8
4
10
14

8
4
4

6
18
22
12
50
8
4
12
16

8
4
4

4
4

7
6
5
5
5
5

7
5
5
5
5

7
5
5
5
5

~I

-------111_
I
=1
D + 2'- 8"

5"R.

CD

I 0

;....

~
w
w

,..--.---.--

II

1--

a.
w
c

))))))))))

i .. : : : ; : ; : ; : ; : ; : ; : ; : ; .
\..., ................---&.......&...

~..&...:::::!:::----------

. . . . . . . . . . .___.)

I.

3'- 0"

.I

I.

END

10'- 0"

.I

SIDE

2' 9"

1 - 1 ~
r 1t

D+2'-8"
VARIES
VARIES

Co

....1

11:_:_: UllliUJlt:_:_: Wll

BENDING DIAGRAM

1~-----

ISOMETRIC

@(TYP.)

BAR LIST

1'- 0" (TYP.)


(D(TYP.)

91' TO 120' 120' TO 150'

3/4" CHAMFER

0
'

60' OR LESS

SHAFT
DEPTH- Z

SPACES

1'- 0" MIN.


GALVANIZING
(TYP.)

ALLOWABLE
LATERAL
BEARING
PRESSURE
(PSF)

1/2" X 21" X 21"

TOP

ANCHOR ROD- 1" DIAM. x 2'- 9" THREADED 8" MIN.


EACH END; W/2 WASHERS AND 6 HEAVY HEX NUTS

TABLE

1 1/16" DIAM.
HOLE (TYP.)

NOTCH AS REQUIRED
TO CLEAR SHAFT
REINFORCEMENT
WHEN D 4' - 0"

0
(ALL DIMENSIONS ARE OUT TO OUT)
2" RADIUS, UNLESS OTHERWISE NOTED

Concrete below finished groundline shall be placed directly against undisturbed


earth, or alternately, backfill placed around foundation shall be compacted in
conformance with Standard Specification 2-09.3(1)e, method 1 or 4.
All formwork shall be removed.

FOUNDATION TYPES 2 & 3

SIGN BRIDGE {TRUSS-TYPE)


FOUNDATION TYPES 2 & 3
STANDARD PLAN G-70.30-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

SIGN WIDTH
("X" - SEE CONTRACT)
-A-I<=

~B*

__....v

BACK OF SIG N

B~

I"'

iten

~
__/~~

'

(!)

0
iii (.)

~
z

__. "'

J:

~ (!)

LUMINAIRE BRACKET (TYP.)

I.

--'--

3" (TYP.)

ONE SIGN LIGHTING LUMINAIRE

BRACE PLACEMENT

("X" - SEE SIGN SPEC. SHEET IN CONTRACT)

.--

!---e*

-A

_.-/

---.

B*

..

/_A/

B~

--,

(!)

.....

'

(!)

J:

it I
W "'

__.

...

~
::::!:

~ Co

(.)

iii
J:

z (!)
z
~

4. Galvanize all non-stainless steel parts.

8'- 0"

6"

3'- 6"

10'- 0"

6"

4'- 6"

12'- 0"

6"

5'- 6"

14'- 0"

1'- 0"

6'- 0"

16'- 0"

2'- 0"

6'- 0"

VERTICAL BRACE SPACING


WITHOUT SIGN LIGHTING
SIGN WIDTH
("X" - SEE CONTRACT)

-A

<0

~ I.

6"

4'- 3"

20'- 0"

6"

4'- 9"

22'- 0"

6"

5'- 3"

24'- 0"

6"

5'- 9"

26'- 0"

6"

6'- 3"

en
__.

"'

28'- 0"

6"

6'- 9"

30'- 0"

1'- 0"

7'- 0"

32'- 0"

2'- 0"

7'- 0"

3" Z-BAR
(!)

w
w

u;l

6"

4'- 1 1/2"

=
=

36'- 0"

6"

4'- 4 1/2"

it

8'- 0"

1'- 0"

10'- 0"

2'- 0"

12'- 0"

3'- 0"

(SPACES)

14'- 0"

1'- 0"

(.)

2'- 0"

'

..... ~
J: .....
(!) z

16'- 0"
18'- 0"

3'- 0"

::::!:
Co
I

0:

BACK OF SIGN

<0

'

iii
J:

(.)

20'- 0"

1'- 0"

S2 en
U)

22'- 0"

2'- 0"

24'- 0"

3'- 0"

26'- 0"

1'- 0"

28'- 0"

2'- 0"

30'- 0"

3'- 0"

32'- 0"

1'- 0"

z w
w
I

VERTICAL BRACE (TYP.)

IF "B" EXCEEDS THE SPACING LISTED


ON THE VERTICAL BRACE SPACING TABLE,
ADD AN ADDITIONAL VERTICAL BRACE

3" (TYP.)

WINDBEAM (TYP.)

THREE SIGN
LIGHTING LUMINAIRES

(.)

34'- 0"

'

~
.....
z

SIGN
WIDTH

"S" SPACES @ 6' - 0"

18'- 0"

en

___/~

f--A-

LUMINAIRE BRACKET (TYP.)

~~~ ~

VERTICAL BRACE (TYP.)

1/4

=\
__....

BACK OF SIGN

B*

I
WINDBEAM (TYP.)

I
i

t::

3" Z-BAR

1/2

(Monotube), or G-90.30 (Truss) for additional Overhead

B*

TWO SIGN
LIGHTING LUMINAIRES

SIGN WIDTH (W)


1/4

3. See Standard Plan G-90.20


Sign Mounting details .

ONE SIGN
LIGHTING LUMINAIRE

'

-I

SIGN
WIDTH

u; enI
0w =
<0

I"'

WITH SIGN LIGHTING

w
w

2. Windbeam and 3" Z-Bar are aluminum. All nuts, bolts, washers, and other hardware
shall be stainless steel, except as noted.

VERTICAL
BRACE SPACING

&> .....
J: .....

f=

1 ..

VERTICAL BRACE (TYP.)

::::!:

(!)
(.)

rt

--,--

r-'

1\

1. Install Sign Lighting Luminaires (and Brackets) only when required in the Contract.

--A-

ll

3" Z-BAR -1-'


I""
WINDBEAM (TYP .) -r-I=

NOTES

WITHOUT SIGN LIGHTING

34'- 0"

2'- 0"

BRACE PLACEMENT

36'- 0"

3'- 0"

TWO SIGN LIGHTING LUMINAIRES

BRACE PLACEMENT
3" Z-BAR

SIGN WIDTH (W)


("X"- SEE SIGN SPECIFICATION SHEET IN CONTRACT)
1/6

.-

I
I<=

_v

I
i

ll

1 ..

I=
WINDBEAM
(TYP.)

_v

ll

I""

7'BACKO F
SIG N

1/3

+
~
I

1/3

!
!---e*

-A

3" Z-BAR

B*

B*

I
i

WINDBEAM (TYP.)

B*

1/6

B*

B*

~
I

tt

I
I VERTICAL BRACE TYP.
LUMINAIRE BRACKET (TYP.)
THREE SIGN LIGHTING LUMINAIRES

BRACE PLACEMENT

B*

I
i
~

B~

--A-

I
p

r
j_

(!)

"""
f=

\/!

BACK OF SIGN

--.-

J ~ - I.

&> .....
J: .....
' (!) z
0
cn1 iii
J: (.)
__.
w
~

(.)

it

I"'

::::!:

z w
~ (!) en

0:
w

SIGN LIGHTING
LUMINAIRE

"'

<0

'

u;l

OVERHEAD SIGN BRACING


AND LIGHTING PLACEMENT
STANDARD PLAN G-90.10-01

VERTICAL BRACE (TYP.)

SHEET 1 OF 1 SHEET

--'--

APPROVED FOR PUBLICATION

3" (TYP.)

LUMINAIRE
BRACKET (TYP.)

ISOMETRIC VIEW

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

TOP OF SIGN

3/8" X 3 1/2" X 6"


STEEL PLATE (TYP.)

STEEL CHANNEL C5 X 9

LOCKNUT WITH NYLON


INSERT AND WASHER

NOTES
1. Refer to Contract Plans for Monotube Beam Bracket
element sizes, dimensions, and weld symbols.

3/16" RIVET

2. See Standard Plan G-90.1 0 for Sign Bracing and


Lighting Placement details.

3/4" DIAM. HEX NUT


AND WASHER
3/4" DIAM. SIGN
BRACKET ROD
WITH (4) WASHERS
AND (4) LOCK NUTS

3/8" DIAMETER BOLT


WITH (2) WASHERS
AND (1) LOCKNUT

VERTICAL BRACE W4 X 13 STEEL


(SEE NOTE 6)

DETAIL

3. Galvanize all non-stainless steel parts.

3/8" X 4" X 3"


STEEL PLATE

4. See Standard Plan G-90.40 for Sign Lighting details.

~ MONOTUBE BEAM

5.

Hand holes shall be installed at the time of fabrication.


Only additional conduits for lighting accommodations
to previously non-illuminated structures may be installed in field as long as the proper repairs are made to
the structure. For details not shown, see Standard
Plan J-75.40.

6.

For VMS mounting, the Contractor may substitute


W6 x 12 steel or WB x 13 steel sections for the
Vertical Brace W4 x 13 steel.

VIEW0

{
3/4" DIAM. SIGN
BRACKET ROD

VERTICAL BRACE W4 X 13 STEEL

MONOTUBE BEAM

7. 3' - 0" max. Vertical Brace and Monotube Beam


Bracket spacing for walk-in cabinet Type VMS
installation.
VERTICAL BRACE W4 X 13 STEEL
(SEE NOTE 6)

STEEL CHANNEL C5 X 9 (TYP.)

STEEL CHANNEL C5 X 9 (TYP.)

SECTION

DRILL 9/16" HOLES


THROUGH WIDE
FLANGE PER BOLT
- SEE BOLT DETAIL

0
DETAIL

SIGN BRACKET
ROD- WITH
LOCK NUTS
(TYP.)

SIGN FACE

3/8" X 3 1/2" X 6"


STEEL PLATE
LOCK WASHER

SIGN FACE

6" DIAM. HAND HOLE AND


REINFORCEMENT RING (TYP.) INSTALL ON TOP OF MAST ARM AT
EACH SIGN LIGHT LOCATION (TYP.)
(SEE NOTE 5)

MONOTUBE
BEAM

8. An acceptable alternative to a Locknut with nylon


insert shall be as follows:
Nylock Blue Nylon Torque-Patch
Nylock Precote 30
ND Patch 360 Ring Patch
All products shall be applied the full length of the bolt
threads with 360 degrees coverage.

C5

HARDENED
WASHER (TYP.)

9 STEEL
CHANNEL

WIND BEAM (TYP.)

1/2" DIAMETER
LONG BOLT

1 1/2"

HORIZONTAL 3" Z-BAR


AT TOP OF SIGN

SIGN BRIDGE OR CANTILEVER


MONOTUBE BEAM

BOLT DETAIL
I i \

~ref.
I

13/16" X 1" SLOTTED


HOLE IN CHANNEL
FOR VERTICAL BRACES WITH
LUMINAIRES, USE DETAILS BELOW
MATCHLINE ON LUMINAIRE
BRACKET DETAIL - STANDARD
PLAN G-90.40

MATCHLINE

MONOTUBE BEAM --~


BRACKET (TYP.)

SIGN LIGHTING LUMINAIRE


-WHEN SHOWN IN THE
CONTRACT, SEE STANDARD
PLAN G-90.40

WIND BEAM AND


POST CLIP (TYP.)

OVERHEAD SIGN MOUNTING


(MONOTUBE STRUCTURE)
STANDARD PLAN G-90.20-02
SHEET 1 OF 1 SHEET

VERTICAL BRACE W4 x 13 STEEL (TYP.)


(SEE NOTE 6)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

BOTTOM OF SIGN
SIDE VIEW

PERSPECTIVE VIEW

MONOTUBE CONNECTION

MONOTUBE STRUCTURE

LUMINAIRE BRACKET (TYP.)


-WHEN SIGN LIGHTING IS
SHOWN IN CONTRACT

......

STATE DESIGN ENGINEER

3125113
DATE

. . . Washington State Department of Transportation

NOTES
1. U-Bolts, Washers and Nuts shall be stainless steel, except as noted.
2. See Standard Plan G-90.10 for Overhead Sign Lighting details.
TOP OF SIGN

3. Galvanize all non-stainless steel parts.


4.

3/16" RIVET

For VMS mounting, the contractor may substitute W6 x 12 Steel or


W8 x 13 Steel sections for the Vertical Brace W4 x 13 Steel.

5. 3' - 0" MAX. Vertical Brace spacing for Walk-In Cabinet Type VMS
installation.

VERTICAL BRACE W4 X 13 STEEL


(SEE NOTE 4)

U-BOLT CONNECTION (TYP)

TOP TRUSS
CHORD

3/8" DIAMETER BOLT


WITH (2) WASHERS
AND (1) LOCKNUT

VERTICAL BRACE W4 X 13 STEEL


(SEE NOTE 4)

DETAIL

en
en
::J
c:::

6. An acceptable alternative to a Locknut with Nylon insert shall be as


follows:
Nylock Blue Nylon Torque-Patch
Nylock Precote 30
ND Patch 360 Ring Patch
All products shall be applied the full length of the bolt threads with
360 degrees coverage.

DRILL 1/2"
HOLE (TYP.)

SIGN FACE

ILL.

VERTICAL BRACE W4 X 13 STEEL


(SEE NOTE 4)

J:

1-

a.

LLJ
Cl

HORIZONTAL 3" Z-BAR


AT TOP OF SIGN
SIGN FACE

U-BOLT CONNECTION 3/8" DIAM. U-BOLT,


WITH 2 LOCKNUTS AND
FLAT WASHERS (TYP.)

DETAIL

SIGN BRIDGE OR
CANTILEVER TRUSS

BOTTOM
TRUSS
CHORD

FOR VERTICAL BRACES WITH LUMINAIRE'S


USE DETAILS BELOW MATCHLINE ON
LUMINAIRE BRACKET DETAIL, SEE STANDARD
PLAN G-90.40
MATCHLINE
WIND BEAM AND
POST CLIP (TYP.)
WIND BEAM (TYP.)

U-BOLT CONNECTION (TYP.)

SIGN LIGHTING LUMINAIRE (TYP.) WHEN SHOWN IN THE CONTRACT,


SEE STANDARD PLAN G-90.40
BOTTOM OF SIGN
SIDE VIEW

TRUSS CONNECTION

VERTICAL BRACE (TYP.) W4 X 13 STEEL (TYP.)


(SEE NOTE 4)

OVERHEAD SIGN MOUNTING


(TRUSS STRUCTURE)
STANDARD PLAN G-90.30-02

LUMINAIRE BRACKET (TYP.) WHEN SIGN LIGHTING IS


SHOWN IN CONTRACT

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


PERSPECTIVE VIEW

TRUSS STRUCTURE

-~----~s=~=TE~D=Es=IG~N=EN=G~INE-ER
_____ _

3122113
DATE

. . . Washington State Department of Transportation

1'- 1 3/4"

3/16" RIVETS- 4" SPACING


3" Z-BAR

NOTES

6 1/2"

2 1/4"
VERTICAL BRACE W4 X 13 STEEL

(TYP.)

1/4" R
(TYP.)

POST CLIPALUMINUM

3/8" DIAM. X 1 1/2 BOLT, 2


WASHERS, & LOCKNUT
- ONE FLANGE ONLY

SIGN FACE

DETAIL

WINDBEAM AND
POST CLIP (TYP.)

2. See Standard Plan J-75.40 and J-75.45 for Sign


Light Luminaire Electrical Details.

3/8" DIAM. x 1 3/4 BOLT WITH


1 x 5/8 RECTANGULAR HEAD,
WASHER, AND LOCKNUT

VERTICAL BRACE W4 X 13 STEEL

7/16"
DIAM.
(TYP.)

VERTICAL BRACE (TYP.) - W4 X 13

UPPER SIGN
PANEL

~~--------.::...'---=-"-

...-.. ~, .... :
't -

1
~
~

3/8" DIAM. x 1 1/2" BOLT,


WASHER, LOCKWASHER,
AND LOCKNUT (TYP.)

-- -

"~~z~::::::i
::
i

>-----~-i--1

SIGN LIGHTING

~~~~~IRE -

3/16" RIVETS (TYP.)4" STAGGERED SPACING

-0-

WINDBEAM CONNECTION DETAIL


ELECTRICAL
CONDUIT ~

SIGN FACE

WIND BEAM

3/16" RIVET (TYP.) - 4"


STAGGERED SPACING

1. Sign Lighting Luminaire shall include a 3/4" threaded


side entry, a gasketed front entry, a door prop, and 4
mounting holes. Refer to Standard Spec. 8-20.3(13)
for additional requirements.

4 1/4"

:..1 .
..-

LOWER SIGN
PANEL

'
'
-Ef3="---E3-

T-

-~_!_

- - - - ----r-<:3---- - , I

HORIZONTAL SIGN PANEL SPLICE

SEE

1.47/16".1

<: ':_,

~~

.J

TOPVlEW

Ir F

_ _ L _ __ _ _ _ _ _ _

a:

1/2" HOLE THRU


_..l::::t:=r-:-t"""""- TOP FLANGE OF
W4 X 13 (TYP.)

VERTICAL BRACE W4 X 13 STEEL

SIDE VIEW

10 GAGE GALV. STEEL PLATE- ITEM AVAILABLE


FROM LUMINAIRE MANUFACTURER

LUMINAIRE MOUNTING PLATE

LUMINAIRE
MOUNTING
PLATE

WINDBEAM DETAIL

SIGN FACE
FOR VERTICAL BRACES
WITH LUMINAIRES, USE
DETAILS BELOW
THE MATCHLINE ON
LUMINAIRE BRACKET

SIGN LIGHTING LUMINAIRE SEE NOTE 1

TOP VIEW

LUMINAIRE BRACKET

ELECTRICAL
CONDUIT

USE DETAILS ABOVE


THE MATCHLINE ON
VERTICAL BRACE

3/8" DIAM. X 1 1/2 BOLT,


WASHER, LOCKWASHER,
AND LOCKNUT (TYP.)

MATCHLINE
.................,._ ----

MATCHLINE

LUMINAIRE BRACKET
(TYP.)- W4 X 13 STEEL

5'- 3"

VERTICAL BRACE W4 X 13 STEEL

YLI-------1_

1'-10314"

LUMINAIRE MOUNTING
PLATE

VIEW0

________,

SIGN LIGHTING LUMINAIRE SEE NOTE 1

BOTTOM OF SIGN
SIDE VIEW

3/8" DIAM.

VERTICAL BRACE
BOTH
FLANGES

ELECTRICAL
CONDUIT

1 1/2" BOLT

OVERHEAD SIGN
LIGHTING DETAILS

I
3/8"WASHER
LUMINAIRE FIXTURE
HOUSING

STANDARD PLAN G-90.40-01


SHEET 1 OF 1 SHEET

3/8" LOCKWASHER

APPROVED FOR PUBLICATION

3/8" DIAM. LOCKNUT


LUMINAIRE BRACKETW4 X 13 STEEL
SIDE VIEW

LUMINAIRE BRACKET

LUMINAIRE
MOUNTING
PLATE

Pasco Bakotich Ill

LUMINAIRE MOUNTING
PLATE

DETAIL

.....
fll

-----,s=rA=TE=-:D=E=SIG""N'""EN:-:-:Gc:ciN=EE,.-R---

10-14-09
DATE

Washington State Department of Transportation

NOTES

W4x13 (TYP.)

en
z

1. NOT INTENDED FOR USE IN FRONT OF STATIC SIGNS.

w
w

a:

2. FOR MOUNTING THE MAINTENANCE WAL~AY TO A MONOTUBE


SIGN BRIDGE, SEE STANDARD PLAN G-95.20.

[I]

....1
....1

iii

3. FOR MOUNTING THE MAINTENANCE WAL~AY TO A TRUSS-TYPE


SIGN BRIDGE, SEE STANDARD PLAN G-95.30.

( J

---"v-

I
I
I
I

VW4x13

Cl

4. LOCATION OF RAILING SPLICES TO BE DETERMINED BY FABRICATOR.


SEE "RAILING SPLICE DETAIL".
\

' 3 1/2"

WAL~AY

ENTRANCE
(INSIDE OPENING
SWING GATE)

\
\

--

/""'

,_,
--

\
\
\

''

~EL
~~~TING

INSTALL 2 HINGES W/
1/4" S.S. SCREWS

' ' ......


'

SEE DETAIL
GATE STOP
(ATTACH TO
FRAME)

;(

3 1/2" '

------1

W4x 13
c.,.

I
I
I

Ill~ II~

""I''

~-.-,-r-,-,-r-,-,-r-,-,-r-,-,-r-,-Ji"lJ-,-,-.--,-r-.--,-r-.--,-r-.--,-,-.--,-j
"i"'

I
I

'

"

\_

.r

( J

~OEPLATE

I
4'- 0" MAX. (TYP.)

_/

SEE DETAIL

~- W4x13 AND POST -

"'11-r-rrr-.-r-r"''l-r-r"''l-r-rrr-.-r

PLAN

MAINTENANCE WALKWAY

~ - - - W4x13 AND RAILING POST

-r,-,.,.,.,.,.,.,-,-r,-r

W4x13

5'- 0"

ENDVIEW

2" STD. PIPE


HAND RAIL
AND POST
(TYP.)

J4

--~

W4x13

2'- 8"
SEE DETAIL "B"

5'- 0"
I

~ - - - W4x13 AND RAILING POST


SPLICE (TYP.)
(SEE NOTE 4)

MODIFY DIMENSION AS REQUIRED FOR PROPER


FIT-UP WITH THE VMS DOOR OPENING.

MAINTENANCE WALKWAY GATE

ENDVIEW
(!)

MATERIAL SPECIFICATIONS
PIPE

ASTM A 36 OR ASTM A 53
GRADE B, TYPE E OR S,
OR ASTM A 500 GRADE B

i=

~
(!)
L1..

ASTM A36

L1..

ASTM A 500 GRADE B

GALVANIZING FOR PIPE


PLATES AND SHAPES

AASHTO M 111

HIGH STRENGTH BOLTS,


NUTS, & WASHERS; INCL.
MOUNTING BEAM BOLTS

STD SPEC. 9-06.5(3)

ALL OTHER BOLTS

STD SPEC. 9-06.5(1)

:Z

~
Co

2" STD.
PIPE (TYP.)
(RAILING)

~
J:

W/2

W/2

L1..

I-

:::!:
0

I-

a:

STRUCTURAL TUBING

w
0

ll.

0
PLATES AND SHAPES

ll.

TOP OF TOE PLATE

ll.

I-

:::!:
0

a:

L1..

TOP OF GRATING

SPLICE~

2" STD.
PIPE (TYP.)
(POST)

~
J:

J:

('t)

MAINTENANCE WALKWAY
FOR SIGN BRIDGES
4' - 0" MAX. (TYP.)
SEE DETAIL "A"

STEEL GRATING

STANDARD PLAN G-95.10-01

~- W4x13 AND POST


FASTENER
GALVANIZING

---~

PROVIDE A 3/4" DIAM. HOLE IN PIPES, AT


PIPE CROSSINGS, FOR GALVANIZING.

SHEET 1 OF 3 SHEETS
APPROVED FOR PUBLICATION

AASHTO M 232

ASTM A36

ELEVATION

MAINTENANCE WALKWAY

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

en

W4 x 13, PLATE & POST

<t

3/4"

4"

5/8" DIAM. ASTM A 325 H.S. BOLT W/ HEAVY


HEX NUT AND WASHER, GALV. {TYP.),
TIGHTEN PER STD SPEC. 6-03.3{33). \

2" DIAM. STD. PIPE WALL

5" PLATE

w
w

a:

1/8

1 5/8"

[I]

W4x13

....1
....1

iii

1 i

4" \

3/4" PLATE

Cl

~~

<t W4x13,

~--

PLATE & POST

1.314,

2 1/2"

SECTION

CONNECTION PLATE
{SEE DETAIL)

PLAN

1"

STIFFENER {TYP.)

1/2" DIAM. H.S.


BOLTS {TYP.)

en

7 1/4"

HOLES

3/4"

--EB-

en

PLAN

3/8" PLATE

W4x13

[I]

2" DIAM. STD. PIPE

1/2" X 4 1/2"
PLATE

1/4

W4x13

1/2" PLATE

LL.

0
J:
IC..

....1
<(

STIFFENER
1/4" PLATE {TYP.)

Cl

::J

3/8" CHAMFER
{TYP.)

Cl

c;;
z

STIFFENERS,
1/4" X 1 1/2"
BOTH SIDES

CONNECTION PLATE
{SEE DETAIL)
{TYP.)
3/8" CHAMFER

ELEVATION

SECTION

9/16" x 3/4" SLOTTED HOLE


FOR 1/2" BOLTS {TYP.)

ELEVATION

DETAIL "B"

CONNECTION PLATE DETAIL

DETAIL "A"

4"

1" MIN.
1/8" MIN. TO
3/8" MAX.

I'

2" STD. PIPE {RAILING)

OUTSIDE
OF RAIL

INSIDE
OF RAIL

3/4"

!.

5/8"

!'I_ 1/16"

11/16"

~ t-l~ ---nnnnnnnnjJn

Cl

~[ ]-

__ ----------~~--

MAINTENANCE WALKWAY
FOR SIGN BRIDGES

------------------- _-+_----,-.---.-

SLOTTED TYPE SPRING PIN


{ANSI B18.8.2, TYPE 304 STAINLESS STEEL)

DRIVE PIN DETAIL

2" DIAM. STD.


PIPE RAILING
1"

1 1/2" DIAM. STD. PIPE


RAILING SPLICE SECTION
DRIVE PINS {SEE DETAIL)

ELEVATION

RAILING SPLICE DETAIL

SECTION

STANDARD PLAN G-95.10-01


SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


-~----~s=~=JE~D=Es=IG~N=EN=GI~NE=ER~----

06-02-11
DATE

" ' Washington State Department of Transportation

SPAN {DIRECTION OF BEARING BARS)

en
z

w
w

a:

PANEL SPAN {TYP)

[I]

....1
....1

iii

~,---

=~

--1----

Cl

I"

4"MAX.
{TYP.)

"I

_ ____['-

_j

---- - - - -

~,---

a.:
~

_l_

::c

ICl

L
7"

GRATING FASTENER
{TYP.) SEE DETAIL

gr-r--

,---,

/'

'-0

1/4" TOE PLATE

CROSS BAR, 1/8" MIN. THICKNESS {TYP.)

W4x13 {TYP.)

I
0

I
0

\II/

BEARING BAR, 3/16" MIN. THICKNESS {TYP.)

GRATING FASTENER

....1

z
c(

CROSS BAR

a.

8
,......

1"MAX.
CLEAR
{TYP.)

~
I

3/16" CLEARAN CE
BETWEEN END
OF CROSS BAR

s
s

BEARING
BARS
INSTALL AND ARRANGE THE
GRATING FASTENERS
ACCORDING TO THE
GRATING MANUFACTURER'S
RECOMMENDATIONS.

I
-

3/16" MIN.
3/8" MAX.

G
W4x13

<t_ W4x13

PLAN
STEEL GRATING DETAIL

GRATING FASTENER DETAIL

{RAILING NOT SHOWN FOR CLARITY)

1/4" TOE PLATE

1/4" TOE PLATE

EVERY FOURTH BEARING


BAR AND NEAR ALL TOE
PLATE CORNERS

1/8

1 - 12
GRATING FASTENER
SEE DETAIL

GRATING FASTENER
SEE DETAIL
CROSS BAR {TYP.)

CROSS BAR

T
0" MIN.
3/4" MAX.

L1"MIN.

1" MIN.

W4x13

SECTION

BEARING BAR

BEARING
BARS

W4x13

SECTION

MAINTENANCE WALKWAY
FOR SIGN BRIDGES
STANDARD PLAN G-95.10-01
SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

MONOTUBE SIGN BRIDGE

MATERIAL SPECIFICATIONS

en
z

w
a:
w

[I]

PIPE

ASTM A 36 OR ASTM A 53
GRADE B, TYPE E OR S,
OR ASTM A 500 GRADE B

PLATES AND SHAPES

ASTM A 36

STRUCTURAL TUBING

ASTM A 500 GRADE B

GALVANIZING FOR PIPE


PLATES AND SHAPES

AASHTO M 111

HIGH STRENGTH BOLTS,


NUTS, & WASHERS; INCL.
MOUNTING BEAM BOLTS

STD SPEC. 9-06.5(3)

ALL OTHER BOLTS

STD SPEC. 9-06.5(1)

FASTENER
GALVANIZING

AASHTO M 232

STEEL GRATING

ASTM A 36

WIRE ROPE

ASTM A 603 WI CLASS A


WEIGHT ZINC COATED
WIRES THROUGHOUT

....1
....1

iii

Cl

ENTRANCE TO WALKWAY
(SWING GATE INSIDE ONLY)

WALK-IN CABINET TYPE VMS

2'- 6" ----j

5'- 0"

1 - - 1-----1

-{

PLAN

TOP OF VARIABLE MESSAGE SIGN


I

r o

ro

oI
'
''
''
I I
'
''
''
I I
oI
'
''
I I
I I
'
''
I I
I I
L
'
''
'
''
''
''
'
''
''
''
'
''
''
''
''
''
''
-T' ----,,----,,-----.-.---'
''
''
''
'
''
''
''
'
''
''
''
'
''
''
''
-Tr----,,----,,-----.-.---''
''
''
''
''
''
''
''
I I
I I
''
''
oI
oI
L
''
''
I I
I I
''
''
I I
I I
''
''
I I
I I
''
''
,_,
,_,
,_,
,_ I

RAILING

4'- 0" MAX. W4x13 SPACING

3'- 0" MAX. ATTACHMENT BRACKET SPACING

4" MAX. GAP BETWEEN


RAILING POST AND
VMS (TYP.)

SAFETY CABLE AND INTERMEDIATE SUPPORT


ARE OPTIONAL IN THIS ZONE
2'- 0" MIN.

ro

'
''
''
'
''
''
I I
'
''
I I
'
''
'
''
''
'
''
''
'
''
''
'
''
''
---,' ----,-.-----.-.-''
''
'
''
''
'
''
''
'
''
''
'
''
''
---,,---,,---''
''
''
''
''
''
I I
''
''
oI
''
''
''
''
''
''
''
''
''
''
,_,
''
,_,
,_,

I--

-.-.--

r-------1 r-------1 r------1 r------1 r------1 1---

-2._

8'- 0" MAX.


SPACING (TYP.)

\i

......
v

ru

[J

I
I
I

[J

[J I

~ 6'- 0" MIN. FROM

I.

SEE CONTRACT FOR VMS DIMENSIONS

INTERMEDIATE SUPPORT FOR


\IRE ROPE (TYP) (SEE NOTE 3)
I

r-------1

TOP OF GRATE

1'------' 1'------' 1'------' 1'------' 1'------' 1'--------1

3/8" DIAM. WIRE ROPE


(SEE NOTE 4)

SEE CONTRACT FOR


MAINTENANCE WALKWAY LAYOUT

.I

FALL RESTRAINT BRACKET


(TYP.) (SEE DETAIL)

ALLOWABLE ALTERNATE MATERIAL: FEDERAL STANDARD


RR-W-410F TYPE 6 CLASS 3 GALVANIZED.

NOTES

WALKWAY IN THIS ZONE IS REQUIRED


FOR VARIABLE MESSAGE SIGN WITH
DOORS ON EACH END

ELEVATION

1. NOT INTENDED FOR USE IN FRONT OF STATIC SIGNS.


2. FOR MAINTENANCE WALKWAY, RAILING, GRATING, AND TOE PLATE
DETAILS, SEE STANDARD PLAN G-95.10.

MAINTENANCE WALKWAY INSTALLED


ON MONOTUBE SIGN BRIDGE

3. USE TWO LANYARDS THROUGH INTERMEDIATE WIRE ROPE SUPPORT.

(WALKWAYS MAY BE USED WITH OTHER LAYOUTS THAN THAT SHOWN ABOVE)

4. 3/8" DIAM. WIRE ROPE WITH 14 KIPS MIN. BREAKING STRENGTH. THE
WIRE ROPE SHALL BE INSTALLED WITH 450 LBS. OF TENSION, AND
WITH 6" OF TAKE UP ADJUSTMENT AVAILABLE IN THE TURNBUCKLE.

I * = SEE NOTE 51
STRUCTURAL LUG
(INTERMEDIATE SUPPORT)
SEE DETAIL "B" (SEE NOTE 3)
STRUCTURAL LUGS
(SIZE TO FIT ROPE
SPELTER SOCKET)
(TYP.) SEE DETAIL "A"

CLOSED SPELTER
SOCKET (TYP.)

JAW & EYE END OPEN BODY


TURNBUCKLE WITH 14 KIPS
MIN. BREAKING STRENGTH
(GALVANIZED)

5. HANDRAIL FIT-UP WITH VMS DOOR OPENING IS THE RESPONSIBILITY


OF THE CONTRACTOR.

FALL RESTRAINT
BRACKET (TYP.)

5/8" PLATE

SEE NOTE 4

HOLE DIAM.
BOLT DIAM. + 1/16"

1 1/2" R

WHEN AN INTERMEDIATE
CD 5"SUPPORT
IS USED

(!)

DETAIL"A"

(!)
LL.

3/4"

0..

..

:::2!:

4"

8" PLATE
6"

a:

LL.

:Z

MAINTENANCE WALKWAY
MOUNTING FOR
MONOTUBE SIGN BRIDGE
STANDARD PLAN G-95.20-02

:il

SHEET 1 OF 3 SHEETS

APPROVED FOR PUBLICATION

2" R
SEE SHEET 2 FOR BRACKET DETAILS

FALL RESTRAINT

3/4" x 3" SLOTTED HOLE

DETAIL "B"

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

PROVIDE A 314" DRAIN


HOLE FOR GALVANIZING,
TOP & BOTTOM (TYP.)

en
z

w
w

114" COVER PLATE


TOP & BOTTOM

a:
[I]

....1
....1

iii

STRUCTURAL LUGS
SEE DETAIL "A"

TS6x4 x 5116

MONOTUBE
(!)

Cl

'

'

'' J ''

TS6x4 x 5116

~--- ____ :

STRUCTURAL LUG
(INTERMEDIATE SUPPORT)
SEE DETAIL "B" (SEE NOTE 3)

(!)
LL.

+----1----

0..

t_

MONOTUBE BEAM

::2:

_j__

LL.

'

314" H.S. BOLT WI NUT &


2 WASHERS, GALV. (TYP.)

a:

Co

z
'

MONOTUBE

~===~====.

314" H.S. BOLT WI NUT &


2 WASHERS, GALV. (TYP.)
MONOTUBE

FABRICATED FROM
L4x4 x 318
3 1116"

SECTION

ELEVATION VIEW

IH~

STRUCTURAL LUGS
(SIZE TO FIT ROPE
SPELTER SOCKET)
(TYP.) SEE DETAIL "A"

''l
:
:

'

'

'

co

- - t_

FABRICATED FROM
L4X4 X 318

STRUCTURAL LUG
SEE DETAIL "A"

3 1116"

PROVIDE A 314" DRAIN


HOLE FOR GALVANIZING,
TOP & BOTTOM (TYP.)

MONOTUBE - - -

FABRICATED FROM
L4x4 x 318

- - - t_

.....'

TS6x4 x 5116

SECTION

FALL RESTRAINT BRACKET INSTALLATION


ON NEW MONOTUBE SIGN BRIDGE

114" COVER PLATE


TOP & BOTTOM

STRUCTURAL LUGS
SEE DETAIL "A"
318

3" THREAD
EACH END (TYP.)

FALL RESTRAINT--

4"

EXISTING MONOTUBE

(!)

(!)
LL.

0
0..

I-

:!:
0

'

-Co

'

a:

LL.

z
~

'

r---r---:
-----$ :-1' ___ i_

'

FIELD LOCATE 1 118" DIAM.


HOLES @ FRONT AND
BACK OF MONOTUBE (TYP.)

STRUCTURAL LUG
(INTERMEDIATE SUPPORT)
SEE DETAIL "B" (SEE NOTE 3)

II

314" X 13" X 1'- 8" PLATE


I

314" X 13" X 1'- 8" PLATE

-+-I

:'

1" DIAM. ROD Wl2 LOCKNUTS & WASHERS, GALV.


(ASTM A 449) (TYP.) - 4 SETS
REQUIRED PER BRACKET

TS6x4 x 5116

'

------~- --+-~

cp

II

MAINTENANCE WALKWAY
MOUNTING FOR
MONOTUBE SIGN BRIDGE
STANDARD PLAN G-95.20-02
SHEET 2 OF 3 SHEETS

1 118" DIAM. HOLE (TYP.)


EXISTING
MONOTUBE

APPROVED FOR PUBLICATION


2" (TYP.)

ELEVATION VIEW

FALL RESTRAINT BRACKET INSTALLATION


ON EXISTING MONOTUBE SIGN BRIDGE

SECTION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

,--

en

VMS HOUSING

w
a:
w

[I]

....1
....1

ATTACHMENTB RACKET
SEE DETAIL

FACEOFVMS-

iii

MONOTUBE
SIGN BRIDGE

1" MIN. (TYP.) -

VMS HOUSING

W4x13 MOUNTING BEAM (TYP.)

I
I
I
I

I
I
I

Cl

// *

\
\

/
//

r-------------------~ ~r
~
1" MAX. CLR. (TYP.)

WALKWAY ENTRANCE
(INSIDE OPENING
SWING GATE)

''

''

).

I ~LV
PANEL

MONOTUBE

1-

r.
~

' ..... ..... .........

STEEL GRATING
(TYP.)

,....

111-+1--TOP OF
TOE PLATE
TOE PLATE
(ALL-AROUND)

0:::

....1
{)

1\

L,.

l~

I/

TOP OF
GRATING!

"I
:I:

I~

' !l>Till

*=

4'- 0" MAX. (TYP.)

SEE NOTE 5,
LOCATED
ON SHEET 1

W4x13 (TYP.)

~ W4x13 AND POST ~

r'T'

~'--.....--- W4x13 MOUNTING BEAM

~
......

I Ii iI

I"
lJ..
'

'

--r

...,.,.....,.,..

~
~II ~Ill

5'- 0"
I

~ - - - W4x13 AND RAILING POST

---~

MAINTENANCE WALKWAY
PARTIAL PLAN
SECTION
MAINTENANCE WALKWAY
MOUNTING BEAM W4 x 13
SPA. @ 4' - 0" MAX.

C5x9

BEAM~

1" (TYP.)

ALL PARTS~
DRILL 9/16"
HOLE (TYP.)

en
z
oen
-w
en_.
zo

1" (TYP.)

LOCKING HEX NUT W/


NYLON INSERT (TYP.)

3/8" X 3 1/2" X 6"


PLATE (TYP.)

C5x9
3/8" X 4" X 3"
PLATE (TYP.)

W::c
~(!)

3/4" DIAM. SIGN


BRACKET ROD
W/4WASHERS
&4 HEX NUTS

MONOTUBE

9/16" x 3/4" SLOTTED HOLE


(VERT.) FOR 1/2" DIAM.
H.S. MOUNTING
BEAM BOLT (TYP.)

Oz

~j

:JI-ll:

oo
zo
01-

HEX NUT
MOUNTING
BEAM

3/8" X 4" X 3"


PLATE (TYP.)

::!:a::

3/8" X 4" X 3"


PLATE (TYP.)

>-0

!!::0::
a:: a.
w

>

,------------------------------- -'bl,

3/4" DIAM. ROD


C5x9 (TYP.)

VIEW0
i 1 1/4"
~
~

l.....

C5x9

i I 1 1/4"
~~

7/8" x 1" SLOTTED HOLE


IN CHANNEL (TYP.)

MONOTUBE

MAINTENANCE
WALKWAY
MOUNTING BEAM

ATTACHMENT BRACKET DETAIL

SECTION

MAINTENANCE WALKWAY
MOUNTING FOR
MONOTUBE SIGN BRIDGE
STANDARD PLAN G-95.20-02
SHEET 3 OF 3 SHEETS

BRACKET NOTES
SECTION

PAINT ENTIRE ATTACHMENT BRACKET TO MATCH EXISTING


STRUCTURE EXCEPT FOR MOUNTING BEAM.
SIGN, LIGHT, BEAM LENGTHS, SIZE AND SPACING SHALL BE
DETERMINED FROM THE CONTRACT PLANS OR WSDOT
STANDARD PLANS.

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

------~s=~=JE~D=Es=IG~N=EN=GI~NE=ER~---

fll

06-02-11
DATE

Washington State Department of Transportation

MATERIAL SPECIFICATIONS

en
z

w
a:
w

[I]

PIPE

ASTM A 36 OR ASTM A 53
GRADE B, TYPE E OR S,
OR ASTM A 500 GRADE B

PLATES AND SHAPES

ASTM A36

STRUCTURAL TUBING

ASTM A 500 GRADE B

GALVANIZING FOR PIPE


PLATES AND SHAPES

AASHTO M 111

HIGH STRENGTH BOLTS,


NUTS, & WASHERS; INCL.
MOUNTING BEAM BOLTS

STD SPEC. 9-06.5(3)

ALL OTHER BOLTS

STD SPEC. 9-06.5(1)

FASTENER
GALVANIZING

AASHTO M 232

STEEL GRATING

ASTM A36

WIRE ROPE

ASTM A 603 WI CLASS A


WEIGHT ZINC COATED
WIRES THROUGHOUT

....1
....1

iii

Cl

318" DIAM. WIRE ROPE


(SEE NOTE 4)

ENTRANCE TO WALKWAY
(SWING GATE INSIDE ONLY)
I

WALK-IN CABINET TYPE VMS

5'- 0"

3'- 0" MAX. ATTACHMENT BRACKET SPACING

r-----

2' - 6" ------j

4" MAX. GAP BETWEEN


RAILING POST AND
VMS (TYP.)

PLAN

TOP OF VARIABLE MESSAGE SIGN


'I
I 1
I 1
I 1
I 1
I 1
I 1
I 1

r-1
II
II
II
II
II
II
II

=JI 1c ====JI
:I :1
~~I
I

/.~

~~: ~/7
-~

-i

'I
I 1
I 1
I 1
I 1
I 1
I 1
I 1

c""'-=
t,
"

:
1

==JI 1c ====JI 1c ====~~


""": :1
:I :1 ~~~
~

'-1
I

'I
I 1
I 1
I 1
I 1
I 1
I 1
I 1

r-1
II
II
II
II
II
II
II

ft

1~

::
: : \!. 1J. :
~----~ t-----~ r-~~-~
.-----i
.----i .-----i .---t-----

~<:;:

~~~

I
I

1
1

~~~7

2'- 0" MIN.

INTERMEDIATE SUPPORT FOR


\WIRE ROPE (TYP.) (SEE NOTE 3)
\

8' - 0" MAX.


1
SPACING (TYP.) !
I

/.~

I
I

1
I

~~~~~~~~~~~~~~~~~~~~~~b====db~~~ r:F====~'======ffl [:~~=====ill


===l F==~~I(
==1 F====1F= ~Ill
11

II

I 1

II

II
II
II
II

I
I
I
I

II
II
II
II

I
I
I
I
I

I * = SEE NOTE si

'I
I 1
I 1
I 1
I 1
I 1
I 1
I 1

::

""::1

I
I
I
I

1
1
1
1

r-1
II
II
II
II
II
II
II

SAFETY CABLE AND INTERMEDIATE SUPPORT


ARE OPTIONAL IN THIS ZONE

:;...;;.= :J c ====J c ====] "'-..C:


/''
) : ''

11
1
1
1
1

RAILING

4'- 0" MAX. W4x13 SPACING

1
1
1
1
1

11

II
II
II
II
II

I
I
I
I
I

1
1
1
1
1

6' - 0" MIN. FROM


TOP OF GRATE

WALKWAY IN THIS ZONE IS REQUIRED


FOR VARIABLE MESSAGE SIGN WITH
DOORS ON EACH END

FALL RESTRAINT BRACKET


(TYP.) (SEE DETAIL)

SEE CONTRACT FOR


MAINTENANCE WALKWAY LAYOUT

SEE CONTRACT FOR VMS DIMENSIONS

ALLOWABLE ALTERNATE MATERIAL: FEDERAL STANDARD


RR-W-410F TYPE 6 CLASS 3 GALVANIZED.

NOTES

ELEVATION

1. NOT INTENDED FOR USE IN FRONT OF STATIC SIGNS.

MAINTENANCE WALKWAY INSTALLED


ON TRUSS-TYPE SIGN BRIDGE

2. FOR MAINTENANCE WALKWAY, RAILING, GRATING, AND TOE PLATE


DETAILS, SEE STANDARD PLAN G-95.10.

(WALKWAYS MAY BE USED WITH OTHER LAYOUTS THAN THAT SHOWN ABOVE)

3. USE TWO LANYARDS THROUGH INTERMEDIATE WIRE ROPE SUPPORT.


4. 318" DIAM. WIRE ROPE WITH 14 KIPS MIN. BREAKING STRENGTH. THE
WIRE ROPE SHALL BE INSTALLED WITH 450 LBS. OF TENSION, AND
WITH 6" OF TAKE UP ADJUSTMENT AVAILABLE IN THE TURNBUCKLE.

114" COVER PLATE


TOP & BOTTOM (TYP.)

PROVIDE A 314" DRAIN


HOLE FOR GALVANIZING,
TOP & BOTTOM (TYP.)

STRUCTURAL LUG
(INTERMEDIATE SUPPORT)
SEE DETAIL "B" (SEE NOTE 3)

5. HANDRAIL FIT-UP WITH VMS DOOR OPENING IS THE RESPONSIBILITY


OF THE CONTRACTOR.
114

318

R = (CHORD O.D.)I2
TS6x4 x 5116

114" (TYP.)

314" PLATE (TYP.)

(!)
11..

0
D..

314" DIAM. U-BOLTS


WI HEX LOCK NUTS
& FLAT WASHERS

JAW & EYE END OPEN BODY


TURNBUCKLE WITH 14 KIPS
MIN. BREAKING STRENGTH
(GALVANIZED)

1-

::!!
0

a:
u..

314" PLATE WI
13116" DIAM. HOLES
FOR U-BOLTS

314" DIAM.
U-BOLT (TYP.)

(TYP.) 114

VIEW0

MAINTENANCE WALKWAY
MOUNTING FOR
TRUSS-TYPE SIGN BRIDGE
STANDARD PLAN G-95.30-02
SHEET 1 OF 2 SHEETS

BOTTOM
CHORD

APPROVED FOR PUBLICATION

8"

8"

ELEVATION

FALL RESTRAINT DETAIL

Pasco Bakotich Ill


06-02-11
-----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

,---

en
z

w
w

VMS HOUSING

TRUSS-TYPE
SIGN BRIDGE

a:

' ~))

[I]

....1
....1

'1>-t/

FACEOFVMS-

iii

W4 x 13 MOUNTING BEAM (TYP.)

Cl

I
I
I

I
\
\

VMS HOUSING

1" MIN. (TYP.)


\

/
/
/
//

WALKWAY ENTRANCE
(INSIDE OPENING
SWING GATE)

I
I
/

''

-~

''

7.

~LV

~
,..;..,

tv

PANEL

' '-...

TRUSS-TYPE
SIGN BRIDGE

STEEL GRATING
(TYP.)

1" MAX. CLR. (TYP.)

i,!_
TOP OF
TOE PLATE
TOE PLATE
(ALL-AROUND)

1\

1\

"T
l..lJ..
,' I,'

4' - 0" MAX. (TYP.)

rvrv

TOP OF
GRATING!

~- W4x13 AND POST - ~

.~

1"
l:.L

I Ti i I

''

"'VV

LOCATED
ON SHEET 1

~lt

~
......
''

l'-

W4x13 MOUNTING BEAM

~'1

= SEE NOTE 5,

N-

0:::

....1
{)

5'- 0"
I

~ - - - W4x13 AND RAILING POST

MAINTENANCE WALKWAY
PARTIAL PLAN

SECTION

-. 1 1/8" I
I

~
I
I

---~

1 1/8"
!--1

3/8" DIAM. U-BOLTS


W/ HEX LOCK NUTS
& FLAT WASHERS

3/4" x 4" x 8" PLATE


6"
5/8" PLATE

HOLE DIAM.
BOLT DIAM. + 1/16"

1 1/2" R

r.i""' 5" WHEN AN INTERMEDIATE


\ V SUPPORT IS USED

2" R
TRUSS CHORD
3/4" x 3" SLOTTED HOLE

W4x13 MOUNTING BEAM

DETAIL"A"
DETAIL "8"

SECTION

MAINTENANCE WALKWAY
MOUNTING FOR
TRUSS-TYPE SIGN BRIDGE
STANDARD PLAN G-95.30-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-02-11
DATE

Washington State Department of Transportation

NOTE
Backfill with soil removed from hole
- See planting area soil preparation
detail or Special Provisions.

INSTALL PLANT
VERTICALLY

MULCH & COMPOST TO SPECIFIED DEPTH FEATHER TO BASE OF PLANT


UPPERMOST ROOT SHALL BE NO MORE THAN
1" BELOW SOIL SURFACE
MULCH & COMPOST TO
SPECIFIED DEPTH FEATHER TO BASE
OF PLANT

UPPERMOST ROOT SHALL BE NO MORE THAN


1" BELOW SOIL SURFACE
MOUND SOIL TO FORM
WATERING WELL AT DRIPLINE
OF EACH PLANT

MOUND SOIL TO FORM WATERING WELL


AT OUTER EDGE OF PLANTING HOLE
12" DIAM .

....1
....1

SEE NOTE

0
0

SEE NOTE

::::i

a:
w

LL.

SEE NOTE
EXISTING SOIL
BREAK UP ROOTBALL OF CONTAINER
PLANTS, PRUNE CIRCLING ROOTS

PLAN

THE ROOT SPREAD

EXISTING SOIL

3 TIMES

EQUALLY SPACE BULBS


- DEPTH VARIES BY SPECIES

THE ROOT SPREAD

SLOPE PLANTING DETAIL

EXISTING SOIL

{INCLUDES ALL PLANTS


ON SLOPES)

SHRUB, TREE AND GROUND COVER PLANTING DETAIL

PLANT RHIZOME WITH CROWN I GROWTH POINTS


AT FINISHED GRADE

SECTION

FINISHED GRADE

BULB PLANTING DETAIL

SEE NOTE
EXISTING SOIL

UPPERMOST ROOT SHALL BE NO MORE THAN


1" BELOW SOIL SURFACE

TUBER OR RHIZOME PLANTING DETAIL

LOWER WRAPPED {B&B) ROOTBALL INTO HOLE. CUT AWAY ALL


WRAPPING MATERIALS FROM ROOTBALL AND REMOVE FROM HOLE,
ROUGHEN SOIL AT EDGES OF ROOTBALL TO STIMULATE ROOTS

MULCH & COMPOST TO


SPECIFIED DEPTH FEATHER TO BASE
OF PLANT

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

MOUND SOIL TO FORM WATERING WELL


AT OUTER EDGE OF PLANTING HOLE

SALLY A. ANDERSON
UPPERMOST ROOT SHALL BE NO MORE
THAN 1" BELOW SOIL SURFACE

CERTIFICATE NO. 000372


SEE NOTE
THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPI..JCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLICA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

, - - - - - - NOTE:

SEE NOTE

EXISTING SOIL
USING 36" )( 2" )( 2" STAKES, STAKE THROUGH EDGE
OF ROOTBALL INTO EDGE OF UNDISTURBED SOIL.
STAKES SHALL BE FLUSH WITH GROUND
SURFACE OR JUST BELOW

SPREAD ROOTS OUT

EXISTING SOIL
BREAK UP ROOTBALL OF CONTAINER
PLANTS, INCLUDING PLUGS
PRUNE CIRCLING ROOTS

TREE AND SHRUB


PLANTING DETAILS
STANDARD PLAN H-1 0.10-00

PLANTING HOLE 3 TIMES


THE ROOT SPREAD

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

STREET TREE PLANTING AND STAKING DETAIL


(APPLIES TO CONTAINER, BALL AND BURLAPPED, {B&B)
DECIDUOUS AND CONIFERS)

EMERGENT PLANTING DETAIL

Pasco Bakotich Ill

.....
VI

-----,s=rA=TE=-:D=E=SIG""N'""EN:-:-::Gc:ciN=EE"'"R---

07-03-08
DATE

Washington State Department of Transportation

(I

CUT DAMAGED END TO LEAVE


TWO BUDS EXPOSED

NOTES
SEE NOTES

FILL VOIDS WITH NATIVE SOIL

2. Do not use axe or sledge for driving


stakes.
3. In hard ground use an iron bar or star
drill to prepare the holes for the stake.

><

010
~

g:

....1
....1

a.

Cl
Cl

<(

::J

EXISTING SOIL

1. See Plant Material List for size and type


of live stake.

c:::
w

4. Avoid stripping bark or bruising stakes during


installation.
5. Fill void around cutting with soil.

LL.

EXISTING SOIL

LIVE STAKE INSTALLATION IN RIPRAP

TYPICAL LIVE STAKE INSTALLATION

CUT DAMAGED END TO LEAVE


TWO BUDS EXPOSED
CUT DAMAGED END TO LEAVE
TWO BUDS EXPOSED
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

SEE NOTES

SALLY A. ANDERSON
CERTIFICATE NO. 000372

MIN. 6" BURIAL INTO


EXISTING SOIL

LIVE STAKE
INSTALLATIONS

EXISTING SOIL

STANDARD PLAN H-10.15-00

EXISTING SOIL

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

LIVE STAKE INSTALLATION IN QUARRY SPALLS

LIVE STAKE INSTALLATION ON SLOPES

fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

NOTES

CAP

1. All Angle Irons and Steel Straps shall be galvanized


in accordance with AASHTO M 232.

318"- 16 x 3" HEX BOLT, STEEL


WITH 1" WASHER

STEEL ANGLE IRON


81 - 0" X 2" X 2 11

2. Pipe, Caps, and T-Adapter shall be 1" I.D. white


PVC, or Primed Steel, except the water intake pipe
shall be white PVC. Pipe shall be Sch. 40. All pipe
joints shall be threaded.

114" DIAM. HOLE (1) FOR AIR EXCHANGE


318"- 16 HEX NUT WITH 1" WASHER
ANGLE IRON EXTENSION
-SEE NOTE 3

'

.....

3. Gage assembly pipe, fiberglass rod, and angle iron


can be extended as needed to fit site requirements.
Extra Pipe Clamps shall be added for security.

EXTENSION SPLIT PIPE CLAMP

4. Score the water intake pipe 1/4" deep, 1/32" wide


(width of saw blade}, every 1/2", alternating cuts
on top and bottom for drainage. Place at lowest
water level.

114" x 6' LONG FIBERGLASS ROD


1" I.D. SCHEDULE 40 PVC
OR PRIMED STEEL PIPE

114" x 6' FIBERGLASS ROD

SECTION

PIPE- SEE NOTE 2

"'"

.....

5. Water level may vary, depending on season .

112" DIAM. HOLE (TYP.)

6. Pour in approximately 1 tablespoon of cork dust at


installation, and after each reading.

EXTENSION SPLIT PIPE CLAMP (TYP.)

WATER LEVEL- SEE NOTE 5

318"- 16 X 314" HEX BOLT


WITH LOCK NUT (TYP.)

112" DIAM.
HOLE (TYP.)

STEEL STRAP (TYP.)


-SEE DETAIL
114" STEEL

SOIL SURFACE

ANGLE IRON

STEEL STRAP

:Z

:iE

114" x 6' FIBERGLASS ROD

Co

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

6"

~ANGLE IRON
-SEE DETAIL

ANORA L.SALISBURY
CERTIFICATE NO. 000860

T-ADAPTER- SEE NOTE 2

NOTE: THIS Pl..AN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLJCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APF'ROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

CUT POINT ON BOTH LEGS


PVC CAP
1" I.D. X 6" PVC
WATER INTAKE PIPE
-SEE NOTE 4

CREST GAGE

CREST GAGE

ANGLE IRON DETAIL


(SHOWN WITH EXTENSION)

CAP

STANDARD PLAN H-30.10-00


SHEET 1 OF 1 SHEET

WATER INTAKE AND CLEANOUT ASSEMBLY

DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC VIEW

10-12-07

...... Washington State Department of Transportation


fll

-------=ST~M=E~DE=s=IG~NE=N=GI~NE=ER~-----

DATE

WEATHER RESISTANT
BATTERY COMPARTMENT
OPTICAL
READER

MOISTURE-PROOF (POTTED)
INTERNAL DATA LOGGER

REMOVABLE ADJUSTER CAP


BENTONITE
PELLETS

"0" CALIBRATION
POINT MARKER
"0" CALIBRATION POINT
(FINISHED GRADE)

WELL SCREEN SLOTS BEGIN


(ALL SLOTS 0.01")

WELL SCREEN

NO.1 SAND OR PEA GRAVEL


....1

:E

(!)

z
z

15
w
w

c...
0

en

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

tt:

MARK W. MAURER
CERTIFICATE NO. 000598
WELL SCREEN SLOTS END

END OF PROBE

THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

. - - - - - - - - - - - ' NOTE:

AUTOMATED GROUND
WATER MONITORING WELL
STANDARD PLAN H-32.1 0-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

2" MIN. ANNULUS AROUND WELL SCREEN

Pasco Bakotich Ill

.....

09-20-07
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

fJ'I Washington

State

DIRECTION OF PEDESTRIAN/
BICYCLE TRAFFIC

en
z

w
w

a:

DIRECTION OF PEDESTRIAN/
BICYCLE TRAFFIC

1'- 2 1/2" DIAM.

[I]

....1
....1

iii
;>..:

1/2" REFLECTIVE TAPE (TYP.)

[I]

Cl

POST

STEEL PIPE - ASTM A 53, NPS 3


(3" NOM.), SCHEDULE 80

1/2" REFLECTIVE TAPE (TYP.)

ROUND FOOTING

SQUARE FOOTING

PLAN VIEW

BASE ASSEMBLY

l*ma~'-/-~

CHAIN
FINISHED GRADE

1/8

1/8

1/4" CHAIN - GRADE 3,


6" LONG

. !J. .

t>

1/8" X 1 7/8"
SQUARE PLATE

..

PAINT ASSEMBLY WITH A "HIGHLY VISIBLE" COLOR.


(SAFETY YELLOW IS ACCEPTABLE)

CAP

1/8

'!J.

1/4" X 1 1/2" X 2" STEEL PLATE


WITH ROUNDED CORNERS
AND 3/4" CENTERED HOLE

CAP
1/8

COVER PLATE
SEAL
WELD

CONCRETE FOOTING COMMERCIAL


CONCRETE

1/8" X 1 7/8"
SQUARE PLATE

POST
POST SLEEVE

NOTE
GRANULAR, FREE
DRAINING MATERIAL

SECTION

This ballard does not have an effective breakaway


design feature and cannot be installed within the
Design Clear Zone.

BASE PLATE

TOP PLATE

0
1/8" PLATE

4 3/4" DIAM.

BASE ASSEMBLY

3 13/16" DIAM.

1/8" PLATE

STEEL PIPE - ASTM A 53, NPS 4


(4" NOM.), SCHEDULE 40
-WELD TO TOP PLATE

3/4" DIAM.
DRAIN HOLE

1 1/4" x 2", FULL SURFACE,


HEAVY DUTY, WELD-ON HINGE

1/8" PLATE

CX)

BOLLARD TYPE 1

CX)

1/8"

I
8 1/2"

COVER PLATE

.1

1 1/4"

STANDARD PLAN H-60.10-01

4 1/2" DIAM.
STEEL PLATE
X

SHEET 1 OF 1 SHEET

1/2" CHAMFER
(TYP.)

1 1/4"

APPROVED FOR PUBLICATION

CAP AND HINGE


8 1/2"

TOP PLATE

BASE PLATE
POST SLEEVE

Pasco Bakotich Ill


07-03-08
-----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

en
z

w
w

a:

NOTE

[I]

....1
....1

iii

This ballard does not have an effective


breakaway design feature and cannot be
installed within the Design Clear Zone.

1/2" REFLECTIVE TAPE (TYP.)

Cl

STEEL PIPE - ASTM A 53,


NPS 3 (3" NOM.),
SCHEDULE 80

POST

1/2" REFLECTIVE TAPE (TYP.)


FINISHED GRADE

5/16" DRILLED HOLE

CONCRETE FOOTING COMMERCIAL


CONCRETE
6" x 1/4" DIAM. STEEL BAR

t>

..

t>

..

FRONT VIEW

0
SECTION

SIDE VIEW

PAINT ASSEMBLY WITH A "HIGHLY VISIBLE" COLOR.


(SAFETY YELLOW IS ACCEPTABLE)

POST

0
1'- 2 1/2" DIAM.

BOLLARD TYPE 2
STANDARD PLAN H-60.20-01
ROUND FOOTING

SQUARE FOOTING

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

PLAN VIEW

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

WOOD POST FASTENERS


QUANTITY
SIZE/TYPE
3/8" DIAM. X 4 3/4" BOLT
2
3/8" DIAM. X 3/4" BOLT
4
3/16" DIAM. x 1" SCREW
4

STEEL POST FASTENERS

WASHERS LOCKNUTS

SIZE I TYPE
QUANTITY
2
3/8" DIAM. X 2 3/4" BOLT
4
3/8" DIAM. X 3/4" BOLT
3/16" DIAM. x 1" SCREW
4
2
1 7/8" M-CLAMP

WASHERS LOCKNUTS

4
8
8
4

2
4
4
4

NOTES
MAILBOX- SIZE 1, 1A,
OR 2 (SIZE 1A SHOWN)
(SEE TABLE, SHEET 2,
FOR DIMENSIONS)

1 . A socket and wedge anchoring system that meets the


NCHRP 350 crash test criteria may be substituted in lieu
of the anti-twist plate designs shown. Anti-twist plates are
not required for wood post installations.
2. The platform design shown on this plan features slots that
accommodate several types of mailbox supports; only those
slots necessary for assembling the type being installed are
required. An adjustable platform may be used in lieu of
this design, but it must fit the bracket design shown on this
plan. Brackets are required for all single-post installations.
Field drilling may be necessary.

3/16" x 1" PHILLIPS HEAD


SCREW, 2 WASHERS,
AND LOCKNUT WITH
NYLON INSERT (TYP.)
-4SETS MIN.

PLATFORM- SEE DETAIL,


SHEET 2 AND NOTE 2

PLATFORM- SEE DETAIL


AND NOTE 2

ADDITIONAL WASHERS
-AS REQUIRED TO
FILL GAP (TYP.)

3/8" x 4 3/4" HEX HEAD


BOLT, 2 WASHERS &
LOCKNUT, LENGTH
TO FIT (TYP.)

4. Attach a newspaper box to a steel post with two 1 7/8"


Muffler Clamps spaced 4" apart. Field drill 7/16" holes in
the newspaper box to fit. Use 2 1/2" x 1/4" lag bolts to
attach newspaper boxes to wood posts. Newspaper boxes
must not extend beyond the front of the mailbox when the
mailbox door is closed.
5. A Type 2 Support (Standard Plan H-70.20) is required when
2 or more mailboxes are to be installed on one support.

BRACKET (TYP.)
(SEE DETAIL,
SHEET2)
3/8" X 2 3/4" HEX BOLT
2WASHERS&
LOCKNUT (TYP.)

BRACKET (TYP.)SEE DETAIL, SHEET 2


3/8" x 3/4" HEX BOLT
2 WASHERS AND
LOCKNUT (TYP.)

4"

3. Center the mailbox on the platform to ensure space for the


mailbox door to open and to allow space for installing the
fasteners (see ALIGNMENT DETAIL, Sheet 2). Spacing
of mailbox mounting holes varies among manufacturers.
Attachment of the mailbox to the platform may require drilling additional holes through the mailbox to fit the platform.

~ct

!:l

4"

ANTI-TWIST PLATE- SEE DETAIL,


SHEET 2 AND NOTE 1

7/16" HOLE
(TYP.)

7/16" HOLE (TYP.)

7/16" HOLE (TYP.)

J~~HERS~)
3/8"

STEEL POST - SEE


STD. SPEC. 9-32.1

4 x 4 WOOD POST - SEE


STD. SPEC. 9-28.14(1)

ANTI-TWIST PLATE -SEE DETAIL,


SHEET 2 AND NOTE 1

2 3/4" HEX

~OLT,NUT&2

STEEL POST

~}

MAILBOX SUPPORT
TYPE 1
STANDARD PLAN H-70.10-01

'

1 7/8" MUFFLER CLAMP (1 7/8" M-CLAMP)


2 LOCKNUTS & 2 WASHERS (TYP.)

WOOD POST ASSEMBLY DETAIL


SEE STEEL POST ASSEMBLY DETAIL
FOR SPECIFICATIONS NOT SHOWN

STEEL POST ASSEMBLY DETAIL

ALTERNATE
ANTI-TWIST PLATE
DESIGN

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

VARIABLE
O"TO 12"

MAILBOX & PLATFORM DIMENSIONS


MAILBOX DIMENSIONS PLATFORM DIMENSION~
L
w
H
L
w
H
19"
6 1/2"
8 1/2"
17"
6"
1"
21"
8"
10 1/2"
19"
7 1/2"
1"
11 1/2" 13 1/2"
21"
11"
1"
24"

SIZE
1
1A
2

f-------7_1_/2_"_ _____,I

t_s-

2 3/4" I
7/16" X 1 1/4"
SLOT (TYP.)

BACK OF SIDEWALK

c_j

o====

-1
-1

FACE OF CURB

-Lu...::...-......--::........,--.=....

5/16" X 1 1/4"
SLOT (TYP.)

: 1 118"

-i

VARIABLE
O"T012"

EDGE OF SHOULDER
OR TURNOUT

SYMMETRICAL ABOUT
CENTERLINE

ro
I

~~

STEEL OR
WOOD POST

~
:::!:

:::!::::!:
ro~

CURB TYPE
VARIES

M M

AT EDGE OF
SHOULDER

"'"'

SIDEWALK

BEHIND CURB

BEHIND SIDEWALK

-IC UNLESS OTHERWISE SHOWN IN THE PLANS

MAILBOX PLACEMENT SECTIONS


END

5/8" R. (TYP.)

3/16" (TYP.)

MAILBOX, PLATFORM, & POST

i
i

MAILBOX
1/4"

5/8"

'SLOT(1YP.)

MAILBOX MOUNTING HOLE (TYP.)

i
i

SIDE

PLATFORM DETAIL

SYMMETRICAL ABOUT ~
7/16" DIAM.
HOLE (TYP.)

y
i

HOLE PLACEMENT FOR


ALTERNATE DESIGN (TYP.)

I f.I

i
i
i
i

I=

'----!

w
a.

a.

J,

SPACE PROVIDED ON BOTH


ENDS TO ALLOW ACCESS TO ------::>
FASTENERS - SEE NOTE 3

31 - 3" MIN. O.C.


POSTTOPOST

PLATFORM

=I

ALIGNMENT DETAIL

4 1 - 3" MIN.

~ ~1---- -------- ---~t-L--$.~-C')

..q-

.---

--------+------j------.

. .-. ---- --------e-- ),!


or-

_j
TOP
7/16" DIAM.
HOLE (TYP.)

7/16" DIAM.
HOLE (TYP.)

&
--~r-L-- '+' -i

! 11/4"

6"
1 1/2"

NEWSPAPER BOX
-SEE NOTE4

ANTI-TWIST PLATE DETAIL

-r,--

co

ANTI-TWIST PLATE- SEE


DETAILS AND NOTE 1

SIDE

ISOMETRIC

MAILBOX SUPPORT
TYPE 1
STANDARD PLAN H-70.10-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

STEEL POST
WOOD POST

FRONT

BRACKET DETAIL

''
''
''
''
''
''
''
''
''
''
''
''
''
L J

POST PLACEMENT DETAIL

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

NOTES

MAILBOX- SIZE 1, 1A, OR 2


(SIZE 1A SHOWN)- SEE TABLE,
STANDARD PLAN H-70.10, SHEET 2,
FOR DIMENSIONS

1. The anchoring system shall meet NCHRP 350 crash test criteria. Use a socket
and wedge system or the anchoring system supplied by or recommended by
the Type 2 Support manufacturer.
2. A maximum of five mailboxes may be installed on a Type 2 Support.

3/16" x 1" PHILLIPS HEAD SCREW,


2 WASHERS, AND LOCKNUT
WITH NYLON INSERT (TYP.)
-4SETS MIN.

3. The Platform design shown in this plan is detailed in the PLATFORM DETAIL,
Standard Plan H-70.10, Sheet 2. The design features slots that accomodate
several types of mailbox supports; only those slots necessary for assembling the
type being installed are required. An adjustable platform may be used in lieu of
this platform design. Adjustable platforms must fit the 1 7/8" M-Ciamp.

SNOW GUARD -WHEN REQUIRED


-SEE DETAIL, SHEET 2

4. Center the mailbox on the platform to ensure space for the mailbox door to open
and to allow space for installing the fasteners (see ALIGNMENT DETAIL).
Spacing of mailbox mounting holes varies among manufacturers. Attachment of
the mailbox to the platform may require drilling additional holes through the
mailbox to fit the platform.

ADDITIONAL WASHERS
-AS REQUIRED TO
FILL GAP (TYP.)

5. Attach a newspaper box to a Type 2 Support with two 1 7/8" Muffler Clamps
spaced 4" apart. Field drill 7/16" holes in the newspaper box to fit. Newspaper
boxes must not extend beyond the front of the mailbox when the mailbox door
is closed.

PLATFORM- SEE NOTE 3

<t
1 7/8" MUFFLER CLAMP
(1 7/8" M-CLAMP),
2 WASHERS AND
2 LOCKNUTS (TYP.)

MAILBOX, PLATFORM
&SUPPORT

MAILBOX~

o======1=
I

i
i
i

SPACE PROVIDED ON BOTH


ENDS TO ALLOW ACCESS TO ----:;, I
FASTENERS -SEE NOTE 4
'---j

TYPE 2 MAILBOX SUPPORT SEE STANDARD SPECIFICATION 9-32.7


NEWSPAPER BOX
-SEE NOTE 5

<i>

I--

PLATFORM

\$

01

ALIGNMENT DETAIL
SEE NOTE4

MAILBOX SUPPORT
TYPE2
STANDARD PLAN H-70.20-01

ASSEMBLY DETAIL

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-16-12
DATE

. . . Washington State Department of Transportation

I
EDGE OF SHOULDER
OR TURNOUT

i
i

c_j

VARIABLE
6"T012"

VARIABLE
0" TO 12"

I
i

BACK OF SIDEWALK

c_j

o::====

_J_LJ....:...--r-:=:-r-.=...J
~~

ANGLE IRON

(TYP.)

::::!:::::!:

rnc:n
'

-It

-It

::::!:::::!:
fn(n

::::!::::!!:

~~

-It

o::====

-LLJ....:...--r-:=:-r-.=...J

1'- 6"
1/8

VARIABLE
O"TO 12"

'

'

CURB TYPE
VARIES

C<Jc-,

~~

rnc:n

'

'

C<Jc-,

'

C<Jc-,

SIDEWALK

1/2" RAISED
EXPANDED
METAL

AT EDGE OF
SHOULDER

BEHIND CURB

BEHIND SIDEWALK

-It UNLESS OTHERWISE SHOWN IN THE PLANS

1/2" RAISED
EXPANDED METAL

SECTION

MUFFLER
CLAMP

MAILBOX PLACEMENT SECTIONS

FRONT VIEW
7/16" DIAM. (TYP.)

\r "i"l
11/4" 11/4"

BOTTOM VIEW

SNOW GUARD DETAIL

:I

.....
w
a.

C"'l

C"'l

a.

4' -3" MIN.

C"'l

a.

a.

4'- 3" MIN.

ANCHORING SYSTEM SOCKET AND WEDGE SHOWN


(SEE NOTE 1)

SNOW GUARD -WHEN REQUIRED,


PLACE ON LEADING END OF
SUPPORT (SEE DETAIL)

MAILBOX SUPPORT
TYPE2
STANDARD PLAN H-70.20-01
SHEET 2 OF 2 SHEETS

MAILBOX SUPPORT TYPE 1


(WOOD POST SHOWN)

APPROVED FOR PUBLICATION

MAILBOX SUPPORTS TYPE 2

Pasco Bakotich Ill

.....

FOR DETAILS,
SEE STANDARD PLAN 1-70.10

STATE DESIGN ENGINEER

02-16-12
DATE

. . . Washington State Department of Transportation

SPACING DETAIL

NOTES
1. The insert pipe is 1" nominal diameter, Schedule 40 steel pipe, as indicated; all other pipe
shown on this plan is 1 1/4" nominal diameter, Schedule 40 steel pipe. All pipe, couplings,
and elbows shall be galvanized in accordance with ASTM A 153.
2. The vertical support may be cast in a concrete foundation, or bolted to aU-channel post, {see
PLACEMENT DETAIL, Sheet 2). Avoid placing the vertical support in the flow line of a ditch.

MAILBOX- SIZE 1 OR 1A (SIZE 1A SHOWN)


-SEE TABLE, STANDARD PLAN H-70.10,
SHEET 1, FOR DIMENSIONS

3. The pipe angles required in this design may be achieved by using pipe fittings or by bending
the pipes. See DETAIL "A," Sheet 2.
4. Coat the 1" diam. pipe with grease {petroleum) before sliding the 1 1/4" diam. pipe (cantilever
arm) onto it, to aid rotation and to guard against corrosion.
5. The Platform design shown in this plan is detailed in the PLATFORM DETAIL, Standard Plan
H-70.10, Sheet 2. The design features slots that accommodate several types of mailbox supports; only those slots necessary for assembling the type being installed are required.

3/16" x 1" PHILLIPS HEAD SCREW,


2 WASHERS, AND LOCKNUT WITH
NYLON INSERT (TYP.)- 4 SETS MIN.

6. Match the edge of the mailbox platform to the end of the horizontal pipe mount. Center the
mailbox on the platform to ensure space for the mailbox door to open and to allow space for
installing the fasteners. Spacing of mailbox mounting holes varies among manufacturers.
Attachment of the mailbox to the platform may require drilling additional holes through the
mailbox to fit the platform, (see ALIGNMENT DETAIL).

45 ELBOW
-SEE NOTE 3
1 1/4" PIPE x 8" LONG
{THREAD ONE END)

7. Attach a newspaper box to the pipe with two 1 3/4" muffler clamps spaced 4" apart. Newspaper boxes must not extend beyond the front of the mailbox when the mailbox door is closed.

PLATFORMSEE NOTE 5
1" NOM. DIAM. SCHED. 40 PIPE
x 9" LONG - SEE NOTE 4
& DETAIL "A," Sheet 2

Cf.

MAILBOX & PLATFORM

ADDITIONAL WASHERS
-AS REQUIRED TO
FILL GAP {TYP.)

45 ELBOW
-SEE NOTE3

1 1/4" PIPE x 2 3/4" LONG


(THREAD ONE END)

MAILBOX

1 3/4" MUFFLER CLAMP


{1 3/4" M-CLAMP), 2 WASHERS
AND 2 LOCKNUTS (TYP.)

VERTICAL SUPPORT1 1/4" PIPE, LENGTH AS REQUIRED


{THREAD BOTH ENDS)

MAILBOX MOUNTING HOLE {TYP.)

-1

MATCH END OF PIPE ~

c-

I !-----"

~----'P-1 -----l~!-"'_

SPACE PROVIDED ON BOTH


ENDS TO ALLOW ACCESS TO
FASTENERS

PLATFORM

HORIZONTAL MOUNT1 1/4" PIPE, LENGTH AS REQUIRED


{THREAD ONE END)

PIPE

_ __ ;

SEE NOTE 6

ALIGNMENT DETAIL
SIDE VIEW

INSTALL PLASTIC
CAP OR PLUG

U.S.
MAIL

ASSEMBLY DETAIL
ISOMETRIC VIEW

COUPLING

MAILBOX SUPPORT
TYPE3

TOP OF FOUNDATION

STANDARD PLAN H-70.30-02

NEWSPAPER BOXWHEN REQUIRED


{SEE NOTE 7)

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

NEWSPAPER BOX
ATTACHMENT DETAIL
ELEVATION VIEW

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

~
....,

VARIABLE
6"TO 12"

::::l

rn

11/4" PIPE

::.::
0:::

HORIZONTAL
MOUNT

<(

::!!:

o:====

;:;..:
ID

8" R.

1 1/4" PIPE X 8" LONG


(THREAD ONE END)

wen
~ rnz
~ ::::::s
O::a..

::!!:

4'- 0" MAX.


3' -0" MIN.

Ww
c.,' ::C::c
0 I-I-

45" ELBOW

oz
rnrnz
~ w~
rn :z!o
::::l::C

I-

z
c.,'

VERTICAL SUPPORT

~rn

1" NOM. DIAM. SCHED. 40


PIPE X 9" LONG
-SEE NOTE4

1" NOM. DIAM. SCHED. 40 PIPE


x 9" LONG - SEE NOTE 4

45" ELBOW

8" R.

1 1/4" PIPE X 2 3/4" LONG


(THREAD ONE END)
DITCH FLOWLINE
11/4" PIPE

VERTICAL
SUPPORT

7/16" DIAM. HOLES


THROUGH PIPE
& CHANNEL (TYP.)

PIPE BENDING ANGLES

PIPE FITTING ANGLES


COMMERCIAL
CONCRETE

3/8" DIAM. X 2 1/2"


HEX HEAD BOLT, NUT
& WASHER (TYP.)

DETAIL

1 1/4" DIAM. X 28" PIPE


(THREAD BOTH ENDS)

COUPLING

z
~
0
'

DIAM.

~
~

CONCRETE
BASE

U-CHANNEL POST
3LB/FT

3'- 3" O.C. MIN.


U-CHANNEL
BASE

PLACEMENT DETAIL
SECTION VIEW

VERTICAL
SUPPORT
11/4" PIPE

3/8" DIAM. X 2 1/2"


HEX HEAD BOLT, NUT
& WASHER (TYP.)

(.)

MAILBOX SUPPORT
TYPE3

u:::

U-CHANNEL POST
3 LB/FT

1-

SECTION

STANDARD PLAN H-70.30-02

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

SPACING DETAIL
ELEVATION VIEW

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

02-07-12
DATE

. . . Washington State Department of Transportation

NOTE

(f)

w
0:::
w

STAPLE TOP TIE

ID

SELF-LOCKING TIE - NYLON 6/6 (MIN. GRADE),


50# MIN. TENSILE STRENGTH, UV STABILIZED

...J
...J

iii

2x2 WOOD POST

Cl

SELF-LOCKING TIE - NYLON 6/6 (MIN. GRADE),


50# MIN. TENSILE STRENGTH, UV STABILIZED

FENCING
MATERIAL

FENCING
MATERIAL

1. Post shall have sufficient strength and durability


to support the fence through the life of the project.

STEEL T-BAR POST

6'- 0" MAX.


VERTICAL POST

ELEVATION

FENCE ON SLOPE

\''
b

2'- 0"
(DESIRABLE)

ENVIRONMENTALLY
SENSITIVE AREA
BOUNDARY

ELEVATION

HIGH DENSITY POLYETHYLENE OR


POLYPROPYLENE MESH, AND SHALL BE
UV RESIST
, ORANGE COLOR

1'- 0" MIN.


(DEEPER FOR
UNSTABLE SOIL)

>l.l..l<

PROTECTED
AREA

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

>l.l..l<

_ L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

MARK W.MAURER

2x2WOOD OR
STEEL T-BAR POST

CERTIFICATE NO. 000598

TYPICAL SECTION

HIGH VISIBILITY FENCE


WORK
AREA

STANDARD PLAN 1-10.10-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

ISOMETRIC

.....

STATE DESIGN ENGINEER

08-11-09
DATE

fll Washington State Department of Transportation

POST - SEE STD. SPEC. 8-01.3(9)A

NOTES

ATTACH IN A MANNER THAT ASSURES FABRIC


IS FIRMLY HELD BY THE BACKUP SUPPORT
IN A WAY THAT REDUCES THE POTENTIAL
FOR FABRIC TEARING

1. Install the ends of the silt fence to point slightly upslope to prevent
sediment from flowing around the ends of the fence.
2. Perform maintenance in accordance with Standard Specifications
8-01.3{9)A and 8-01.3{15).
3.

BACKUP
SUPPORT

Splices shall never be placed in low spots or sump locations. If


splices are located in low or sump areas, the fence may need to be
reinstalled unless the Project Engineer approves the installation.

4. Install silt fencing parallel to mapped contour lines.

BACKFILLED &
COMPACTED
NATIVE SOIL

SEE NOTE 1

SELF-LOCKING TIE-NYLON 6/6 (MIN. GRADE),


120# MIN. TENSILE STRENGTH, UV STABILIZED

BURY GEOTEXTILE
IN TRENCH

GEOTEXTILE FOR SILT FENCE - SEE STANDARD


SPECIFICATION SECTION
9-33.2 (1 ), TABLE 6

NOTE
DURING EXCAVATION, MINIMIZE DISTURBING THE GROUND
AROUND TRENCH AS MUCH AS IS FEASIBLE, AND SMOOTH
SURFACE FOLLOWING EXCAVATION TO AVOID CONCENTRATING FLOWS. COMPACTION MUST BE ADEQUATE TO
PREVENT UNDERCUTTING FLOWS.

POST
- WOOD OR STEEL
(TYPICAL)

TYPICAL INSTALLATION DETAIL


(STEEL POSTS SHOWN)

.-

____ 1

--- ---

,,....

n:::

-------

--

Ll:(
1..1::

/
/ /

1,,
~

rn
z
w
w

SEE NOTE 1

---

~,"'

----:--; / ' .1: ~


-q:.,..
--

------- --/
,

"'

"'
"' "'

BACKUP
SUPPORT
(TYPICAL)

"' "'

.,.~

:::
~

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

INSTALL BACKUP SUPPORT FOR


THE GEOTEXTILE - SEE STANDARD
SPECIFICATION SECTION 8.01.3(9)A

ANORA L.SALISBURY
CERTIFICATE NO. 000860

TYPICAL SILT FENCE


WITH BACKUP SUPPORT

ISOMETRIC

FABRIC
(GEOTEXTILE)
(TYPICAL)

(STEEL POSTS SHOWN)

0::
III

MENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

STANDARD PLAN 1-30.10-02

MENT BUT AN ElECTRONIC DUPLICA 1E. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLfCATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPART-

SILT FENCE
WITH BACKUP SUPPORT

..J
..J

iii

, - - - - - _ . . J NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCU

SPLICED FENCE SECTIONS SHALL BE CLOSE ENOUGH TOGETHER


TO PREVENT SILT LADEN WATER FROM ESCAPING THROUGH THE
FENCE AT THE OVERLAP.

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

SPLICE DETAIL
(STEEL POSTS SHOWN)

.....

STATE DESIGN ENGINEER

3122113
DATE

. . . Washington State Department of Transportation

POST - SEE STD.


SPEC. 8-01.3{9)A

NOTES
1. Install the ends of the silt fence to point slightly upslope to prevent
sediment from flowing around the ends of the fence.
2. Perform maintenance in accordance with Standard Specifications
8-01.3(9)A and 8-01.3(15).
3. Splices shall never be placed in low spots or sump locations. If
splices are located in low or sump areas, the fence may need to be
reinstalled unless the Project Engineer approves the installation.

BACKFILLED &
COMPACTED
NATIVE SOIL

4. Install silt fencing parallel to mapped contour lines.

SELF-LOCKING TIE-NYLON 6/6 (MIN. GRADE),


120# MIN. TENSILE STRENGTH, UV STABILIZED

BURY GEOTEXTILE
IN TRENCH

'.'

I II
I II
J,ll

I
I
I

}~ ~

'.'
I

II

'.'
I

II

1-r ' '

"' ' '


I

Ill

'I'

NOTE
DURING EXCAVATION, MINIMIZE DISTURBING THE GROUND
AROUND TRENCH AS MUCH AS IS FEASIBLE, AND SMOOTH
SURFACE FOLLOWING EXCAVATION TO AVOID CONCENTRATING FLOWS. COMPACTION MUST BE ADEQUATE TO
PREVENT UNDERCUTTING FLOWS.

GEOTEXTILE FOR SILT FENCE- SEE STANDARD


SPECIFICATION SECTION
9-33.2 {1 ), TABLE 6
POST
- WOOD OR STEEL
(TYPICAL)

TYPICAL INSTALLATION DETAIL


(STEEL POSTS SHOWN)

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

FASTEN TO POST

EVERY 6" O.C ~

ANORA L.SALISBURY
CERTIFICATE NO. 000860
FABRIC (GEOTEXTILE)
(TYPICAL)

~-----'

NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCU

MENT BUT AN ElECTRONIC DUPLICA 1E. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLfCATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

TYPICAL SILT FENCE


WITHOUT BACKUP SUPPORT

ISOMETRIC

SILT FENCE

(STEEL POSTS SHOWN)

STANDARD PLAN 1-30.15-02


SHEET 1 OF 1 SHEET

SPLICED FENCE SECTIONS SHALL BE CLOSE ENOUGH


TOGETHER TO PREVENT SILT LADEN WATER FROM
ESCAPING THROUGH THE FENCE AT THE OVERLAP.

SPLICE DETAIL
(WOOD POSTS SHOWN)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


3122113
- - - - STATE
- -DESIGN
- -ENGINEER
-----DATE

.....

. . . Washington State Department of Transportation

POST- SEE STD. SPEC. 8-01.3(9)A

NOTES

ATTACH IN A MANNER THAT ASSURES FABRIC


IS FIRMLY HELD BY THE BACKUP SUPPORT
IN A WAY THAT REDUCES THE POTENTIAL
FOR FABRIC TEARING

1. Install the ends of the high visibility silt fence to point slightly upslope
to prevent sediment from flowing around the ends of the fence.
2. Perform maintenance in accordance with Standard Specifications
8-01.3{9)A and 8-01.3{15).
3.

BACKUP
SUPPORT

Splices shall never be placed in low spots or sump locations. If


splices are located in low or sump areas, the fence may need to be
reinstalled unless the Project Engineer approves the installation.

4. Install silt fencing parallel to mapped contour lines.

BACKFILLED &
COMPACTED
NATIVE SOIL ::tl

INSTALL BACKUP SUPPORT FOR THE GEOTEXTILE


-SEE STANDARD SPECIFICATION SECTION 8.01.3(9)A
SELF-LOCKING TIE-NYLON 6/6 (MIN. GRADE),
120# MIN. TENSILE STRENGTH, UV STABILIZED

~:

/11::
//
:::
~

BURY GEOTEXTILE
IN TRENCH
,.... ,.,.C.IAIJ1"Y /

/ //
...- ~'

,.,......

...-

NOTE
DURING EXCAVATION, MINIMIZE DISTURBING THE GROUND
AROUND TRENCH AS MUCH AS IS FEASIBLE, AND SMOOTH
SURFACE FOLLOWING EXCAVATION TO AVOID CONCENTRATING FLOWS. COMPACTION MUST BE ADEQUATE TO
PREVENT UNDERCUTTING FLOWS.

...- ...-

...-

...- ...-

...- ...-

,.,."

..,.'

......- ...-

...- ...-

...-

.,.""'
...-

/ l i""'
n"
,. .... (I

~~:~

~:~

.::
.. ..

/-

/'

GEOTEXTILE FOR HIGH VISIBILITY SILT FENCE


COLOR- ORANGE- SEE STANDARD
SPECIFICATION SECTION
9-33.2 (1), TABLE 6

POST
- WOOD OR STEEL
(TYPICAL)

BACKUP
SUPPORT
(TYPICAL)

Ill

:::

..... 1..........

...........

----:-. ~~

-- ---/ r,,,,

---::::::::---/-

TYPICAL INSTALLATION DETAIL

----::---

(STEEL POSTS SHOWN)

----

----~:::L

----

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

~&<8>~~

] /_//-

SEE NOT

/-

'H

0~

~"'<?'

ANORA L.SALISBURY
CERTIFICATE NO. 000860

TYPICAL HIGH VISIBILITY SILT FENCE


WITH BACKUP SUPPORT

FABRIC
(GEOTEXTILE)
(TYPICAL)

ISOMETRIC
(STEEL POSTS SHOWN)

w
w

0:::
Ill
..J
..J

iii

~
c

MENT BUT AN ElECTRONIC DUPLICA 1E. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLfCATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

HIGH VISIBILITY
SILT FENCE
WITH BACKUP SUPPORT

Cl)

, - - - - - - - - - ' NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCU-

STANDARD PLAN 1-30.16-00


SPLICED FENCE SECTIONS SHALL BE CLOSE ENOUGH TOGETHER
TO PREVENT SILT LADEN WATER FROM ESCAPING THROUGH THE
FENCE AT THE OVERLAP.

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

SPLICE DETAIL
(STEEL POSTS SHOWN)

.....

STATE DES!GN ENGiNEER

3122113
DATE

. . . Washington State Department of Transportation

en
z

NOTES

POST - SEE STD.


SPEC. 8-01.3(9)A

w
0::
w

1. Install the ends of the high visibility silt fence to point slightly upslope
to prevent sediment from flowing around the ends of the fence .

ID

....1
....1

iii

2. Perform maintenance in accordance with Standard Specifications


8-01.3{9)A and 8-01.3{15).

3. Splices shall never be placed in low spots or sump locations. If


splices are located in low or sump areas, the fence may need to be
reinstalled unless the Project Engineer approves the installation.

FASTEN GEOTEXTILE TO
POST EVERY 6" (IN.) O.C.

4. Install silt fencing parallel to mapped contour lines.

BACKFILLED &
COMPACTED
NATIVE SOIL

SELF-LOCKING TIE-NYLON 6/6 (MIN. GRADE),


120# MIN. TENSILE STRENGTH, UV STABILIZED

GEOTEXTILE FOR HIGH VISIBILITY SILT FENCE


COLOR- ORANGE - SEE STANDARD
SPECIFICATION SECTION
9-33.2 (1), TABLE 6

NOTE
DURING EXCAVATION, MINIMIZE DISTURBING THE GROUND
AROUND TRENCH AS MUCH AS IS FEASIBLE, AND SMOOTH
SURFACE FOLLOWING EXCAVATION TO AVOID CONCENTRATING FLOWS. COMPACTION MUST BE ADEQUATE TO
PREVENT UNDERCUTTING FLOWS.

TYPICAL INSTALLATION DETAIL


POSTWOOD OR STEEL
(TYPICAL)

(STEEL POSTS SHOWN)

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

TYPICAL HIGH VISIBILITY SILT FENCE


WITHOUT BACKUP SUPPORT

ISOMETRIC

ANORA L.SALISBURY

(STEEL POSTS SHOWN)

CERTIFICATE NO. 000860

FASTEN GEOTEXTILE TO
POST EVERY 6" (IN.) O.C.

, . . . - - - - - - - NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ElECTRONIC DUPLICA 1E. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLfCATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

HIGH VISIBILITY
SILT FENCE
STANDARD PLAN 1-30.17-00
SHEET 1 OF 1 SHEET
SPLICED FENCE SECTIONS SHALL BE CLOSE ENOUGH TOGETHER
TO PREVENT SILT LADEN WATER FROM ESCAPING THROUGH THE
FENCE AT THE OVERLAP. JOINING SECTIONS SHALL NOT BE PLACED
IN LOW SPOTS OR IN SUMP LOCATIONS.

SPLICE DETAIL
(WOOD POSTS SHOWN)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

3122113
DATE

. . . Washington State Department of Transportation

NOTE
SILT FENCE - SEE
STD. PLAN 1-30.10
PLACE SAND BAGS AS REQUIRED
AROUND CULVERT TO PROVIDE
SUPPORT FOR SILT FENCE

Perform maintenance in accordance with Standard


Specification 8-01.3(9}A and 8-01.3(15}.

GEOTEXTILE FOR TEMPORARY SILT FENCE


-SEE STD. SPEC. 9-33.2(1), TABLE 6

II

:Z

POST-SE E STD. SPEC. 8-01.3(9)A)

b
'

CULVERT, BOX CULVERT, OR PIPE ARCH


-END TREATMENT VARIES

EMBED POSTS INTO SAND


BAGS A S REQUIRED

i'i'i rlfl
Ill

:E
b

....'

FLOW 'tnz

SILT FENCE DESIGN

:Z

~
EDGE OF GEOTEXTILE

SECTION

COMPOST BERM - SEE


STD. PLAN 1-80.10

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

MARK W. MAURER
CERTIFICATE NO. 000598
THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

, . - - - - - - - - ' NOTE:

CULVERT, BOX CULVERT, OR PIPE ARCH


-END TREATMENT VARIES

EROSION CONTROL
AT CULVERT ENDS
STANDARD PLAN 1-30.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

----~ST~~~E~DE~S~IG~NE~N~GI~NE~ER~---

COMPOST BERM DESIGN

fJ'I Washington

09-20-07
DATE

State Department of Transportation

....1
....1

NOTES

0
0

1. Wattles shall be in accordance with Standard Specification


9-14.5(5). Install Wattles along contours. Installation shall
be in accordance with Standard Specification 8-01.3(10).

::J

z
c:::

CONTOUR LINE (TYP.)

11..

./

. //

ALLOWABLE ALTERNATIVE
TIE-DOWN METHOD

ANGLE TERMINAL END UPHILL 24" TO 48"


TO PREVENT FLOW AROUND WATTLE
(TYP.)

,...
/

TRENCH - SEE NOTE 1

~ ~ ~~

.;---;,
;

-'1>

4.

11' ...
,

'I>

'

"'. . . .

...,

'

I\

...

- 'C'

I
I

;
...t;>

Install Wattle perpendicular to flow along contours.

........

5. Wattles shall be inspected regularly, and immediately after


a rainfall produces runoff, to ensure they remain thoroughly
entrenched and in contact with the soil.

'..

\"' , \

.. . ~~ _. _- ... , 1.

'"""'fLL~~r

2. Securely knot each end of Wattle. Overlap adjacent Wattle


ends 12" behind one another and securely tie together.
3. Compact excavated soil and trenches to prevent undercutting.
Additional staking may be necessary to prevent undercutting.

~~

WATTLE\

,//

2" X 2" X 24" UN-TREATED


WOODEN STAKE (TYP.)

'

...

\.

11'-.

'}

\I;

6.

Perform maintenance in accordance with Standard Specification 8-01.3(15).

7.

Refer to Standard Specification 8-01.3(16) for removal.

8" DIAMETER
MINIMUM
2" X 2" X 24" WOODEN
STAKE (TYP.)

WATTLE DETAIL

AREA AVAILABLE FOR SEDIMENT


TRAPPING (TYP.)

PLAN VIEW

SPACING VARIES -SEE WATTLE


SPACING TABLE (TYP.)

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

Sandra L. Salisbury
SANDRA L SALISBURY
LICENSE NO. 860

8" DIAMETER
WATTLE SPACING TABLE
SLOPE

MAXIMUM SPACING

1H: 1V

10'- 0"

2H: 1V

20'- 0"

3H: 1V

30'- 0"

4H: 1V

40'- 0"

June 10, 2013


,-----___J

NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLJCATE. THE ORIGINAL. SIGNED BY THE ENGINEER AND
APPROVED FOR PUBLICATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

WATTLE INSTALLATION
ON SLOPE
STANDARD PLAN 1-30.30-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SECTION

WATTLE INSTALLATION ON SLOPES

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

NOTES
1. Compost Sock shall be in accordance with Standard Specification

9-14.5(6).

..

...J
...J

...../

ALLOWABLE ALTERNATIVE
TIE-DOWN METHOD

ANGLE TERMINAL END UPHILL 24" to 48"


TO PREVENT FLOW AROUND SOCK
(TYP.)

///

2.

Securely knot each end of Compost Sock. Overlap adjacent Compost


Sock ends 12" behind one another and securley tie together.

3.

Compost to be dispersed on site as determined by the Engineer,


when vegetation covers the surface.

4.

If Erosion Control Blanket is specified, place Compost Sock on top


of blanket. See Standard Plan 1-60.10.

5.

Install Compost Sock perpendicular to flow along contours.

6.

Remove sediment from the up slope side of the Compost Sock


when accumulation has reached 1/2 of the effective height of the
Compost Sock .

....;'

Cl
Cl

::J

//

0:::

w
u..

.....

................

Cl

DISTURBED
AREA

~~PACING VARIES (TY~.~


, SEE COMPOST SOCK ,
I SPACING TABLE I

7.

Perform maintenance in accordance with Standard Specification

8-01.3(15).
8.

Refer to Standard Specification 8-01.3(16) for removal.

I
I

BIODEGRADABLE
EROSION CONTROL BLANKETSEE NOTE 4
COMPOST SOCK (TYP.)SEE DETAIL

2" X 2" X 24" UNTREATED


WOODEN STAKE (TYP.)

PROTECTED
AREA

SECTION

PLAN VIEW
DRAINAGE GRATE (CIRCULAR
GRATE SHOWN)
2"
EXCESS SOCK MATERIAL,
DRAWN IN AND TIED OFF
SECURELY (TYP.)

2"

~~~

WOODEN STAKE

COMPOST SOCK-

SEE NOTE 1

.:-'

Y:.'7~. ~ -:~\

{ '_ :. ' _ ... ~. :.:.


~ :-,
,

8" DIAMETER
COMPOST SOCK SPACING TABLE
SLOPE

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

~I~

24" UNTREATED

'

: _"" _" 'II\ .... ',

COMPOST SOCKSEE DETAIL

EROSION CONTROL BLANKETSEE NOTE 4

DATE:

10'- 0"

2H: 1V

20'- 0"

3H: 1V

30'- 0"

June 6, 2013

7HIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLJCATE. 1HE ORIGINAL. SIGNED BY 1HE ENGINEER AND
APPROVED FOR PUBLICATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

."""

COMPOST SOCK

MAXIMUM SPACING

1H: 1V

12" MIN.
OVERLAP

STANDARD PLAN 1-30.40-01


SHEET 1 OF 1 SHEET
8"

APPROVED FOR PUBLICATION

MINIMUM
4H: 1V

Sandra L. Salisbury
SANDRA L. SALISBURY
LICENSE NO. 860

Pasco Bakotich Ill

40'- 0"

ISOMETRIC VIEW
COMPOST SOCK DETAIL

CATCH BASIN INSTALLATION

.....

STATE DESIGN ENGINEER

yj, Washington

6110113
DATE

Stote Department of Transportation

NOTES
....1
....1

PLUG GAPS BETWEEN LOGS


WITH EXCAVATED

0
0

::J

1. Coir logs shall be installed starting at the bottom of the slope and working uphill.

z
c:::
w

11..

/ ..... / .. /

ALLOWABLE ALTERNATIVE
TIE-DOWN METHOD

'

..... /

.......

//~

2.
CONTOUR LINE (TYP.)

Excavated material shall be spread evenly along the uphill slope and compacted
by hand tamping or other methods approved by the Engineer.

3. Overlap Coir log ends by 12" to prevent water from moving between logs.
4. Always install Coir log perpendicular to slope along contour lines. Ends shall angle
uphill to prevent flow around the Coir log .

...~-
.-
.

---_.,............/ /

5.

__

Use an adequate number of stakes to ensure logs are secure.

6. Coir logs shall be installed in accordance with Standard Specification 9-14.5{7).


7.

COIR LOG (TYP.)

/ / / _ .. /

Perform maintenance in accordance with Standard Specification 8-01.3{15).

....././_ ....../ . / _ .......

...~
LAND I UPHILL

---_.,...... ...//

WATER I DOWNHILL

__

COIRLOG
2" x 2" x 36" MIN. UNTREATED
WOODEN STAKE (TYPICAL)

I
I
I
I II
I II

I )I

'0

I
I
I 11

I 11
I 11
I )1
\_,

ISOMETRIC VIEW
1/4" DIAMETER NATURAL
FIBER ROPE

PLAN VIEW
PLACEMENT ON SLOPE

I
TOP OF STAKES FLUSH
WITH TOP OF LOG

EXCAVATED MATERIAL COMPACTED AND


SPREAD EVENLY ON UPHILL SLOPECOMPACT AGAINST THE UPHILL SIDE OF
LOG TO FORM WATERTIGHT SEAL

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

112" DIAMETER
MINIMUM

Sandra L. Salisbury
SANDRA L. SALISBURY
LICENSE NO. 860

PLAN VIEW

DATE:

June 6, 2013

SPACING DEPENDENT UPON SLOPE TOP OF LOWER COIR LOG IN LINE WITH
BOTTOM OF COIR LOG ABOVE (TYP.)
COIRLOG
SHORELINE- IF APPLICABLE (SEE CONTRACT PLANS)
I
I
I
I I

RECESS APPROX. 1/3 OF LOG INTO SLOPE

I
I
I
I
I I

1)

VIEW

COIR LOG PLACEMENT

ORDINARY HIGH WATER MARK

STANDARD PLAN 1-30.60-00


SHEET 1 OF 1 SHEET

:,~-........7;;4'11\+----...L.__ __
I

ELEVATION VIEW

.....

EROSION CONTROL DETAILS


COIR LOG PLACEMENT

I
I
I I

\ I

,,

....__,.....

APPROVED FOR PUBLICATION

I
I
I
I I
\ I

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5129113
DATE

~ Washington State Department of Transportation

1?7

!
I

i
i
i

0---- l

-----~--f

INLET

NOTES
1. Prefabricated units may be used in lieu of the design
shown on this plan upon approval of the Engineer.

GEOTEXTILE

2. Structure shall be constructed such that geotextile


material shall be fastened to posts creating a seamless joint.

---- ----- r7l

3. Ensure that ponding height of water does not cause


flooding on adjacent roadways or private property.

J
- -- ...JI

4. Perform maintenance in accordance with Standard


Specification 8-01.3(15).

i
i
i
i
i

Li::

----------------

PLAN VIEW
(CROSS BRACES NOT SHOWN)

POST (SEE STD. SPEC. 8-01.3(9)A).

FASTEN CROSS BRACES TOGETHER WITH


SCREWS, NAILS. NYLON TIES OR WIRE

ATTACH WOOD OR METAL CROSS


BRACES TO STABILIZE WOOD

GEOTEXTILE FOR TEMPORARY SILT FENCE


-SEE STD. SPEC 9-33.2(1), TABLE 6 ~

COMPACTED NATIVE SOIL

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

MARK W. MAURER

SILT FENCE - SEE


STD. PLAN 1-30.10

CERTIFICATE NO. 000598


THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

, . - - - - - - - - ' NOTE:

BURY GEOTEXTILE IN TRENCH

TEMPORARY SILT FENCE


FOR INLET PROTECTION
IN UNPAVED AREAS
STANDARD PLAN 1-40.10-00

INLET

SECTION

ISOMETRIC VIEW

SHEET 1 OF 1 SHEET

(ENTIRE FENCE NOT SHOWN


FOR ILLUSTRATIVE PURPOSES)

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

09-20-07
DATE

State Department of Transportation

NOTES

1. Size the Below Inlet Grate Device (BIGD} for the storm water structure it
will service.
2. The BIGD shall have a built-in high-flow relief system (overflow bypass}.
3. The retrieval system must allow removal of the BIGD without spilling the
collected material.
4.

Perform maintenance in accordance with Standard Specification 8-01.3(15}.

DRAINAGE GRATE

GRATE FRAME

r-----1
\.

...._-----" j

DRAINAGE GRATE
- RECTANGULAR GRATE SHOWN

~---

RETRIEVAL SYSTEM (TYP.}

SEDIMENT AND DEBRIS


OVERFLOW BYPASS

[>

BELOW INLET GRATE DEVICE

BELOW INLET GRATE DEVICE


[>

OVERFLOW BYPASS (TYP.)

[>

[>

[>

[>

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

[>
[>

[>

{)
[>

[>

{)
[>

{)
[>

[>

MARK W. MAURER
SECTION VIEW
NOT TO SCALE

CERTIFICATE NO. 000598

ISOMETRIC VIEW

THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPUCA TE. THE ORIGINAL, SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TfON, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATfON. A COPY MAY BE OBTAINED UPON REQUEST.

, . - - - - - - - - ' NOTE:

STORM DRAIN
INLET PROTECTION
STANDARD PLAN 1-40.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

09-20-07
DATE

State Department of Transportation

36" MAX. BETWEEN


STAKES

GENERAL NOTES

BIODEGRADABLE MATERIALSEE STANDARD SPECIFICATION


9-14.5(4) (TYP.)

BIODEGRADABLE MATERIALSEE STANDARD SPECIFICATION


9-14.5(4) (TYP.)

SPACE CHECK DAMS SO THAT


POINTS "A" AND "B" ARE AT
THE SAME ELEVATION

2" )( 2" X 24" UN-TREATED


WOODEN STAKE (TYP.)

1. Check Dams shall meet the requirements of Standard


Specifications 8-01.3(6) and 9-14.5(4).
2. In channels, install the sloped ends of the Check Dam a
minimum of 8" higher than the spillway to ensure water
flows over the dam and not around it.

..J
..J

LlJ

0
0

::::i

c:::

'

--\~
' \ 1 2 " (TYP.)

LlJ
LL.

CHANNEL PROFILE -SECTION


TYPICAL CHANNEL SECTION

3.

Perform maintenance in accordance with Standard


Specification 8-01.3(15).

4.

Remove Check Dams in accordance with Standard


Specification 8-01.3(16).

BIODEGRADABLE CHECK DAM


NOTE

BIODEGRADABLE CHECK DAM

SPILLWAY

1. Biodegradable Check Dams may need additional or


modified staking to prevent undercutting or scouring.

SIDE PROTECTION

NON-BIODEGRADABLE CHECK DAM


NOTES

ELEVATION
EFFECTIVE HEIGHT
VARIES BASED
ON FLOW

8"

SPILLWAY

1. Non-Biodegradable Manufactured Check Dam devices approved


for use under Standard Specification 9-14.5(4) shall be installed
per manufacturer's recommendations and shall perform in accordance with Standard Specification 8-01.3(6).

EFFECTIVE DAM HEIGHT


VARIES BASED
ON FLOW

2. Rock Check Dams shall be placed outside of the clear zone or


behind traffic barrier.

NON-BIODEGRADABLE MATERIALSEE STANDARD SPECIFICATION


9-14.5(4)B (TYP.)

SPACE CHECK DAMS SO THAT POINTS "A" AND "B"


ARE THE SAME ELEVATION
SPILLWAY

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

3. To ensure adequate damming time, Rock Check Dams used as


sediment control may need to be enhanced with plastic that
meets the requirements of Standard Specification 9-14.5(3)
or fabric that meets the geotextile requirements of Standard
Specification 9-33.2(1 ), Table 6.

Sandra L. Salisbury
SANDRA L. SALISBURY
LICENSE NO. 860
DATE:
June 6, 2013
,-----__J

NOTE: 7HIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLJCATE. 1HE ORIGINAL. SIGNED BY 1HE ENGINEER AND
APPROVED FOR PUBLICATION, IS KEPT ON FILE AT THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

FLOWLINE

EXTENDED SECTION

CHECK DAMS ON
CHANNELS
STANDARD PLAN 1-50.20-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

NON-BIODEGRADABLE CHECK DAM

.....

STATE DESIGN ENGINEER

yj, Washington

6110113
DATE

Stote Department of Transportation

NOTES
EXTEND BLANKET FAR ENOUGH OVER
CREST OF SLOPE TO EFFECTIVELY
PREVENT UNDERCUTTING AND TO
PROVIDE SECURE ANCHORING

6" MIN. END


OVERLAP

,, ,
l. ,: , ,
#

.'

STAPLES- 4" APART, ~~ /


STAGGERED, 6" 0. C.

1. More than the minimum of one fastener per square


yard may be required due to conditions such as
blanket composition, soil type, surface uniformity,
and slope steepness.
2. See Standard Specification 8-01.3(3) and 9-14.5)2).

EROSION CONTROL
BLANKET

3.

FASTENER
(TYP.)

4. Additional staples may be required on slopes


greater than 3H : 1V.

18" MAX.
(TYP.)

SHINGLE SPLICE -SECTION

Use manufacturer's requirements. When manufacturer's


requirements are not provided, use installation
requirements shown on Standard Plans.

6" MIN. EDGE


OVERLAP

NATIVE SOIL- FOLLOW


INSTALLATION STEPS

EXTEND BLANKET 24" BEYOND


TOE OF SLOPE OR TO EDGE
OF VEGETATION- WHICHEVER
IS CLOSER

'

EROSION CONTROL
BLANKET

2 ROWS OF STAPLES
4" APART, STAGGERED,
6" 0. C. PLACED WITHIN
6" OF BLANKET EDGE.

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

INSTALLATION STEPS:

SANDRA L. SALISBURY

1. Prepare smooth slope.


2 ROWS OF STAPLE (TYP.)4" APART, STAGGERED, 6" 0. C.

INITIAL ANCHOR- DETAIL

SANDRA L. SALISBURY
LICENSE NO. 860

2. Amend soil and seed, as specified.


3.

DATE:

Dig anchor trench. Set aside native


soil removed from trench.

, - - - - - - - - ' NOTE:

MENT BUT AN ELECTRONIC DUPLICATE. THE ORIGINAL. SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TION, IS KEPT ON FILE AT THE WASHfNGWN STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

4. Secure blanket in anchor trench,


staking or stapling blanket as shown.
5.

Replace native soil previously


removed from trench.

6.

Roll blanket down the slope in a


controlled manner, taking care
to remove excess slack, and taking
care not to stretch blanket.

7. Stake or staple blanket as shown so there


are no gaps between the blanket and the soil.
Staple while unrolling blanket to minimize
walking on blanket.

6/6113

THIS PLAN IS NOT A LEGAL ENGINEERING DOCU-

ISOMETRIC VIEW

BIODEGRADABLE EROSION
CONTROL BLANKET
PLACEMENT FOR SLOPES
STANDARD PLAN 1-60.10-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

SHINGLE SPLICE

NOTES

BLANKET MUST EXTEND 36"


ABOVE THE ANTICIPATED
WATER ELEVATION

ANTICIPATED
WATER LINE

1. More than the minimum of one fastener per square yard may be
required due to conditions such as blanket composition, soil type,
surface uniformity, and flow velocity.

LONGITUDINAL ANCHOR SEE DETAIL

6" (TYP.>

.1 ~

CHANNEL INSTALLATION- SECTION

2.

Install Check Slots per manufacturer's recommendations.

3.

See Standard Specification 8-01.3(3) and 9-14.5(2)

4. Use manufacturer's requirements. When manufacturer's requirements


are not provided, use installation requirements shown on Standard
Plan.

5. Additional staples may be required for high flow exposure.

EROSION CONTROL
BLANKET

II
I I

~I

STAPLE- 18" 0. C. MAX. ___/

TAMPED NATIVE
SOIL

:I :I

LONGITUDINAL
ANCHOR DETAIL

EROSION CONTROL
BLANKET
NATIVE SOIL PILE
FROM TRENCH

CHANNEL TERMINATION DOUBLE ROW OF STAPLES


STAGGERED 6" APART
J I

I I

:: : :---....____ STAPLES (TYP.) - 4" APART,


I I
I I
STAGGERED, 6" 0. C.

TAMPED NATIVE
SOIL FROM PILE

EROSION CONTROL
BLANKET

ISOMETRIC VIEW
6" x 6" TRENCH (TYP.) - SEE
LONGITUDINAL ANCHOR DETAIL

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

INSTALLATION STEPS:

IIll~
I 1
: : : :
STAPLES (TYP.) - 4" APART,
I
STAGGERED, 6" 0. C.

INITIAL ANCHOR- SECTION

1. Prepare smooth slope.

SANDRA L. SALISBURY

2. Amend soil and seed, as specified.

SANDRA L. SALISBURY
LICENSE NO. 860

3.
STAPLE- 6" MAX.
CENTERED\

6" MIN. EDGE OR


END OVERLAP

EROSION
CONTROL
BLANKET

1\6"MIN.

FLOW

II

II

:\_1
I
I I

STAPLE- 36" MAX. ~:


11
CENTERED

CHECK SLOT - SECTION

2 ROWS OF STAPLES
4" APART, STAGGERED

TAMPED NATIVE
SOIL

6"0. C.

SHINGLE SPLICE AT END OF ROLL


SECTION

Dig anchor trench. Set aside native


soil removed from trench.

4. Secure blanket in anchor trench,


staking or stapling blanket as shown.
5.

Replace native soil previously


removed from trench.

6.

Roll blanket parallel to the slope in a


controlled manner, taking care
to remove excess slack, and taking
care not to stretch blanket.

7. Stake or staple blanket as shown so


there are no gaps between the blanket
and the soil. Staple while unrolling
blanket to minimize walking on blanket.

DATE:
, - - - - - - - ' NOTE:

6/6/13

THIS PLAN IS NOT A LEGAL ENGINEERING DOCU-

MENT BUT AN ELECTRONIC DUPLICATE. THE ORIGINAL. SIGNED BY THE ENGINEER AND
APPROVED FOR PUBUCA TION, IS KEPT ON FILE AT THE WASHfNGWN STATE DEPARTMENT OF TRANSPORTATION. A COPY MAY BE OBTAINED UPON REQUEST.

BIODEGRADABLE EROSION
CONTROL BLANKET
PLACEMENT FOR DITCHES
STANDARD PLAN 1-60.20-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

en
z

w
w

a:
[I]

....1
....1

iii

COARSE COMPOST

Cl

GROUND LINE

X
TEMPORARY SILT FENCE
OR COMPOST SOCK

SECTION
OUTFLOW CHANNEL IS

I fONSTRUCTED BY EXCAVATIO~ I

j)_ .
6'- 0" MIN.

1'- DEPT>< OVERFlOW

NOTE

2X

PLACE GEOTEXTILE UNDER THE SPILLWAY AND SIDE SLOPES. PROVIDE A


CONTINUOUS LAYER BETWEEN THE GRAVEUROCK AND THE NATIVE EARTHEN MATERIAL.

X= 1'- 0" FOR SLOPES 4H:1V OR FLATTER


X= 1'- 6" FOR SLOPES STEEPER THAN 4H:1V

TYPICAL SECTION

COMPOST BERM DETAIL


1'- 0" DEPTH
OF 2" - 4" ROCK
1'- 0" DEPTH OF 3/4"- 1 1/2"
WASHED GRAVEL BACKFILL

SECTION

PROVIDE GEOTEXTILE
- SEE STD. SPEC. SECTION 9-33

TEMPORARY SEDIMENT TRAP

EXISTING ROAD

25' - 0" R MIN. (TYP.)

STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT

4" - 8" QUARRY SPALLS

MARK W.MAURER
CERTIFICATE NO. 000598

~---

G)

AS REQUIRED- 100' MIN.,


EXCEPT MAY BE REDUCED
TO 50' MIN. FOR SITES WITH
LESS THAN ONE ACRE OF
EXPOSED SOIL.

PLACE CONSTRUCTION GEOTEXTILE FOR


SOIL STABILIZATION AND A MINIMUM OF 0.15'
CRUSHED ROCK UNDER THE SPALLS, FROM THE
EDGE OF THE EXISTING ROADWAY TO THE RADIUS
RETURNS, OR AS DIRECTED BY THE ENGINEER.

MISCELLANEOUS
EROSION CONTROL DETAILS

1'- 0" MIN.

STANDARD PLAN 1-80.10-01


SHEET 1 OF 1 SHEET

PROVIDE FULL WIDTH OF


INGRESS I EGRESS AREA
15'- 0" MIN.

ISOMETRIC VIEW

STABILIZED CONSTRUCTION ENTRANCE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

08-11-09
DATE

Washington State Department of Transportation

Photoelectr i c
control
Photoelectric
control

Weotherheod
Liqu i d tight flexible
conduit, length 2' MIN,
3' MAX- strop to pole

Weotherheod
Bend conduit to o I I ow
removo I of weotherheod ,
strop below bend

Conduit ond conductors,


s i ze to ut i I i ty
requirements

Bend condu i t to o I I ow
removol of weotherheod,
strop below bend

Bend condu i t to
pole ond strop wi thin
1' obove meter

1" conduit,
three 1t 12
Bend conduit to
pole ond strop with i n
1' obove meter

30' Closs V
treoted timber pole
Meter bose

Meter bose

L i qu i d t i ght flex i ble


conduit, length 2' MIN,
3' MAX- strop to pole
Condu i t ond conductors,
s i ze to ut i I i ty
requirements
1' condu i t,
three 1t 12
30' Closs V
treated timber pole
Bend condu i t to pole ond strop
wi th i n 1' obove cab i net

Bend condu i t to pole ond


strop with i n 1' obove cobinet

3"- 5" nipple


or worp fitting

3" - 5" n i pple


or worp fitting

Hub ond gosket (TYPI

Hub ond gosket


Serv i ce breoker,
120VAC, 1P S/N

Lfl lD

18" MIN
See Note 5

Current ond potential


transformers furnished
ond i nstalled by uti I i ty

L i qu i d t i ght flex i ble


conduit, length 2' MIN,
3' MAX- strop to pole
Weotherheod

1' condu i t, three 1t 12


(four 1t [2 if transformers
ore used)

Bend condu i t to o I I ow
removo I of weotherheod,
strop below bend

Bond

Conduit ond conductors,


s i ze to ut i I i ty
requirements

Bend conduit to
pole ond strop wi thin
18 obove meter

Bend conduit to pole ond strop


wi th i n 1' obove cob i net

Meter bose

Service cobinet
use metol standoffs
to mount to pole

LB Conduit Body

Lfl lD

30' Closs V
treoted timber pole

Photoelectr i c
contol

Service cabinet
use meto I standoffs
to mount to pole

Lfl lD

:z

-===-:;

11)

18" MIN

--\__
Condu i t to lum i no i re,
size os required

TYPE A SERVICE, 120 VOLT

See Note 5

TYPE B SERVICE, 120/240 VOLT

See Note 5

'
'
'
'

18" MIN

'
'
'

~-----:

-\_Condu i t to Lum i noire,


size os requ i red

TYPE C SERVICE, 480 VOLT

TYPE A., B AND C SERVICE


LIGHTING DETAILS

Two Jj5' x 1/ 2"


golvon i zed bolts
Photoelectr i c control
oriented to north sky

-\_Condu i t to luminoire,
size os required

Ill

Timber pole
Two Jj5" x 3"
go I von i zed I og screws
Two 1/ 4 " x 1/ / ' bross bo Its;
dr i I I brocket to f i t meter bose

Threod I ess coup I i ngs ( TYP I

STANDARD PLAN J-3

Conduit body

APPROVED FOR PUBLICATION


Clifford E. Mansfield

PHOTOELECTRIC CONTROL DETAILS

STATE DESIGN ENGINEER

08-01-97
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

Sheet 1 of 2 Sheets

1" conduit. three " 12

NOTES:

I Photoe I ectr i c contro I I

1.

Meter i ng arrangements moy vary wi th d i fferent serv i ng ut i I it i es.


The contractor sha I I ver i fy
the requ i rements of the ut i I i ty pr i or to i nsta I I i ng the serv i ce equ i pment.

2.

All service pole condu i t shall be secured to the pole wi th condu i t strap ot 5' centers.

3.

All r i sers ond serv i ce equ i pment shall be i nstalled on s i de of pole that i s away from traff i c.

4.

Where requ i red by the serv i ng ut i I i ty. serv i ce breakers shall be i nstalled above the
meter socket i n a separate ra i nt i ght enclosure.

5.

Bend ond attach to pole wi th i n 1' of enclosure.


"Typ i co I Ground i ng Deta i Is."

5.

For Type 8 serv i ce wi r i ng d i agram, use Standard Plan "Mod i f i ed Type B Serv i ce"
For Type C serv i ce wiring d i agram, use Standard Plan, "Type E Service."

7.

See breaker schedule in contract for breaker and contactor s i zes.

1P 15 amp 125VAC flasher breaker


Service
2P 240VAC
serv i ce breaker

Branch breaker

D :: D
Test sw i tch

Jack mounted flasher


!where required)

Removable
false front

' '
' '
' '

Subpane I for
equ i pment

'

N
N

See Standard Plan

120 VAC co i
contact or

Neutra I busbar

120 VAC
Meter base
~
I where requ i red I ~!~~ ,)

TYPE B SERVICE CABINET

Test sw i tch
Photoelectr i c
or t i me clock

Welded
hinge
'

Control breaker

''
'

Serv i ce
1' condu i t
three # 12
!Photoelectric
contro I I

ZP 480VAC serv i ce breaker

'

: D :
'
'
'

D:

'
'
'

Test sw i tch

'
'

I~

'--

g"

SECTION A-A
To I i ght i ng standards->[ _ _ _ _ _ _ _ __,

TYPE A WIRING DIAGRAM


120 VOLT

-----,'
'
'

-----1

2P 480VAC branch breaker

Flasher breaker
q
N

;:Jio..--

: D
'
'
'

: D :' D
'
'

'
'

TYPE A., B AND C SERVICE


LIGHTING DETAILS

Removable
false front

Subpone I for
equipment
c
r---

150 VA 480/120 VAC


dry transformer 150
i f flasher used I

Contoctor
1120 VAC coill

q
q

'
'
'
'

'L---

I where required)

I~

STANDARD PLAN J-3

'

APPROVED FOR PUBLICATION


Clifford E. Mansfield

,..

STATE DESIGN ENGINEER

DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


...
OLYMPIA, WASHINGTON
~

TYPE C SERVICE CABINET

08-01-97

Sheet 2 of 2 Sheets

KEY

GENERAL NOTES
200 AMP TYPE 120/240 1111 SERVICE CABINET

BYPASS
TEST ON

1. SEE STANDARD SPECIFICATION 9-29.24, SERVICE CABINETS.

2. HINGES SHALL HAVE STAINLESS STEEL OR BRASS PINS.


3. CABINETS SHALL BE RATED NEMA 3R AND SHALL
INCLUDE TWO RAIN TIGHT VENTS.

PHOTOCELL

4. METERING EQUIPMENT DOOR SHALL BE PAD LOCKABLE.


EACH DOOR SHALL BE GASKETED. INSTALL BEST CX
CONSTRUCTION CORE ON RIGHT DOOR. SEE DOOR HINGE
DETAIL, SHEET 1 OF 2.

TEST

5. THE FOLLOWING EQUIPMENT WITHIN THE SERVICE


ENCLOSURE SHALL HAVE AN APPROPRIATELY ENGRAVED
PHENOLIC NAME PLATE ATTACHED WITH SCREWS OR RIVETS:
KEY NUMBERS 2, 3, 4, 6, 7, 8, 9 AND 16.
KEY NUMBER 4 NAME PLATE SHALL READ:
"PHOTOCELL BYPASS TEST ON" AND "PHOTOCELL TEST
OFF- AUTOMATIC". SEE SERVICE CABINET DETAIL.

VENTS

6. METERING ARRANGEMENTS VARY WITH DIFFERENT


SERVING UTILITIES. THE UTILITY MAY REQUIRE METER
BASE MOUNTING IN THE ENCLOSURE, ON THE SIDE OR
ON THE BACK OF THE ENCLOSURE. THE UTILITY MAY
REQUIRE THE DIMENSION BETWEEN THE DOOR AND
THE FRONT OF THE SAFETY SOCKET BOX TO BE LESS
THAN THE 11 INCHES SHOWN IN THE LEFT SIDE- SAFETY
SOCKET BOX MOUNTING DETAIL. THE CONTRACTOR
SHALL VERIFY THE SERVING UTILITY'S REQUIREMENTS
PRIOR TO FABRICATION OF AND INSTALLING THE
SERVICE EQUIPMENT.
7. DIMENSIONS SHOWN ARE MINIMUM AND SHALL BE
ADJUSTED TO ACCOMMODATE THE VARIOUS SIZES
OF EQUIPMENT INSTALLED.

~- - 1. _19"--------~-1\_

METER BASE PER SERVING UTILITY REQUIREMENTS.


AS A MINIMUM, THE METER BASE SHALL BE SAFETY SOCKET
BOX WITH FACTORY INSTALLED TEST BYPASS FACILITY
THAT MEETS THE REQUIREMENTS OF EUSERC DRAWING 305.

0
0

MAIN BREAKER (SEE BREAKER SCHEDULE)

@
@
@

1'-10"
SEE DOOR
HINGE DETAIL

LEFT SIDE

CD

FRONT
SERVICE CABINET DETAIL

WELD TO EACH END


OF MOUNTING BLOCK
INSIDE FACE
OF DOOR

MOUNTING BLOCK
(TYP.) - SEE DETAIL

8. ALL BUSSWORK SHALL BE HIGH GRADE COPPER AND


SHALL EQUAL OR EXCEED THE MAIN BREAKER RATING.
ALL BREAKERS SHALL BOLT ONTO THE BUSSWORK.
JUMPERING OF BREAKERS SHALL NOT BE ALLOWED.
BUSSWORK SHALL ACCOMMODATE ALL FUTURE
EQUIPMENT AS SHOWN IN THE BREAKER SCHEDULE.

2" )( 3" END PLATE (TYP.)


1/2" UNC S.S.)( 8" LONG
ALL-THREAD, 6 PLACES
(TYP.) - CUT OFF AFTER
ADJUSTMENT, SEE NOTE 18

TYP. 3/32

PLACE NUT AGAINST END


PLATE BEFORE WELDING

~I ~ ~
~

SIDE VIEW

MOUNTING BLOCK DETAIL

STAND-OFF DIMENSION
-SEE NOTE 18

12 GA REMOVABLE PANEL
1/2" RETURN -WELD AT CORNERS

13. UNISTRUT TYPE CHANNEL AND MOUNTING HARDWARE


COMPONENTS SHALL BE STAINLESS STEEL. CONDUIT
CLAMPS SHALL BE HOT DIPPED, GALVANIZED STEEL OR
STAINLESS STEEL.

CONTACTOR (SEE BREAKER SCHEDULE)


RECEPTACLE BREAKER (SPST 20 AMP -120/240 VOLn
RECEPTACLE, GROUNDED (GFCI 20 AMP- 125 VOLn
NEUTRAL BUSS, 14 LUG COPPER
PHOTOCELL ENCLOSURE- ENCLOSURE TO BE FABRICATED
FROM 5/8" EXPANDED STEEL MESH WITH WELDED SEAMS
AND MOUNTING FLANGES. HOT DIP GALVANIZED AFTER
FABRICATION. TYPE 5052- H32 ALUMINUM WITH 5/8" x 5/8"
OPENINGS EQUIVALENT TO 5/8" EXPANDED STEEL MESH
MAY BE USED AS ALTERNATIVE MATERIAL. SEE PHOTOCELL
ENCLOSURE MOUNTING DETAIL, SHEET 2 OF 2.
HINGED FRONT FACING DOOR WITH 4" x 4" MIN. POLISHED
WIRE GLASS WINDOW.

CABINET MAIN BONDING JUMPER. BUSS SHALL BE 4 LUG


TINNED COPPER. SEE CABINET MAIN BONDING JUMPER
DETAIL ON SHEET 2 OF 2.

SPARE BRANCH BREAKER (DPST 20AMP- 120/240 VOLn

METAL WIRING DIAGRAM HOLDER

FOUR 1/4-20 S.S. PANHEAD PHILLIPS


MACHINE SCREWS, WASHERS, AND NUTS
- TOP AND BUTTOM, SPACED EVENLY

BRANCH BREAKER (SEE BREAKER SCHEDULE)


SIGNAL BREAKER (SEE BREAKER SCHEDULE)

@
@
@

THREE 1/2" S.S. NUT (TYP.)

PHOTOELECTRIC CONTROL, STD. SPEC. 9 - 29.11 (2)

HINGED DEAD FRONT WITH 1/4 TURN FASTENERS OR SLIDE


LATCH.

WASHER - EACH SIDE OF THE PANEL

12. A 1% TOLERANCE IS ALLOWED FOR ALL DIMENSIONS.

1/4" DIAMETER DRAIN HOLE. DRILL BEFORE GALVANIZING.


MOUNTING HOLE. SEE SERVICE CABINET MOUNTING DETAILS.
18 CIRCUIT PANEL BOARD- MINIMUM SIZE WITH SEPARATE
MAIN BREAKER.
LABEL CABINET WITH BUSSWORK RATING.

120/240 VAC

LEFT SIDE- SAFETY SOCKET BOX MOUNTING DETAIL

1/4" x 1 1/4" CLOSED CELL


NEOPRENE GASKET
DOOR

15. NOTE 15 HAS BEEN DELETED.

18. VERIFY THE SERVICE UTILITY STAND-OFF DIMENSION.


ADJUST THE REMOVABLE PANEL TO THE MEASUREMENT
PROVIDED BY THE UTILITY COMPANY. AFTER ADJUSTMENT,
CUT OFF ALL-THREAD BOLTS SO THAT NO LESS THAN 2
AND NO MORE THAN 3 FULL THREADS EXTEND PAST THE
FACE OF THE NUTS

12 GA.- MATERIAL TO BE THE


SAME AS CABINET MATERIAL

11. ALL NUTS, BOLTS AND WASHERS USED FOR MOUNTING


THE PHOTOCELL ENCLOSURE SHALL BE STAINLESS STEEL.

17. WHEN USING ALTERNATE DOOR HINGE: REMOVE


HINGE PIN PRIOR TO WELDING HINGE TO CABINET
AND PRIOR TO HOT DIP GALVANIZING CABINET.
AFTER GALVANIZING, REPLACE PIN WITH BRASS PIN
AND SOLDER IN PLACE.

.I ~I

~-=========================~ ~

FRONT SURFACE OF
SAFETY SOCKET BOX

10. ALL INTERNAL WIRE RUNS SHALL BE IDENTIFIED WITH


"TO - FROM" CODED TAGS LABELED WITH THE CODE
LETTERS AND/OR NUMBERS SHOWN ON THE SCHEDULES.
APPROVED PVC OR POLYOLEFIN WIRE MARKING
SLEEVES SHALL BE USED.

16. THE METER BASE PORTION OF THIS SERVICE WAS


DESIGNED TO MEET METERING PORTION OF EUSERC
DRAWING 309 REQUIREMENTS.

,.,12.~v 0

FRONT VIEW

9. THE PHOTOCELL UNIT SHALL BE CENTERED IN THE


PHOTOCELL ENCLOSURE TO PERMIT 360 DEGREE
ROTATION OF THE PHOTOCELL WITHOUT REMOVAL
OF THE PHOTOCELL UNIT OR THE PHOTOCELL
ENCLOSURE.

14. INSTALL CONDUIT COUPLINGS ON ALL CONDUITS.


PLACE COUPLINGS FLUSH WITH TOP OF
CONCRETE FOUNDATION.

~3/32

PHOTOCELL BREAKER (SPST 15 AMP- 120/240 VOLn


TEST SWITCH (SPOT SNAP ACTION, POSITIVE CLOSE
15 AMP- 120/277 VOLT- "T'' RATED)

ILL CKT A

DOOR HINGE DETAIL

ALTERNATE FOR TYPE B MODIFIED CABINET


SEE NOTE 17

ILL CKT B

PIANO
HINGE
TYP. r.1/~8--r7--f'l

DOOR

\-T'+-- HINGE

2" HIGH x 2" OPEN


3/8" BARREL

SERVICE CABINET TYPE B


MODIFIED (0 200 AMP TYPE
120/240 SINGLE PHASE)
STANDARD PLAN .J-3b

:@

PANEL DOOR

1/4" X 5/8"
NEOPRENE
GASKET

SHEET 1 OF 2 SHEETS

SIZE PER NEC.


MINIMUM SIZE #2

DOOR HINGE DETAIL

APPROVED FOR PUBLICATION

WIRING SCHEMATIC

DRAWN BY: MARK SUJKA

VIEWB-B

0112005

REVISED SAFETY SOCKET BOX MOUNTING DETAIL

DATE

REVISION

....

Harold J. Peterfeso

EB
BY

STATE DESIGN ENGINEER

fJ'I Washington

03-04-05
DATE

State Department of Transportation

~EE~:~OT~E~6~~~~~~

r ~me~
><
~

POLICE PANEL

1 5/8" X 1 5/8" 12 GA.


SLOTTED STEEL
CHANNEL BRACKETS
(lWO REQUIRED)

3/8" BOLT (lWO FOR EACH


CHANNEL) NOT REQUIRED
FOR STRUT MOUNT

SPRING NUT
FRONT OF
CONTROLLER
CABINET

II

"

I'

II

CONDUITS AS REQUIRED.
PLUMB CONDUIT 1"
SEE GENERAL NOTE 14

Co
._

SERVICE
CABINET

t.=::::::;::===-1

in

~ ~

:iE

Ill\

BOLT SIZED FOR SLOTTED STEEL


CHANNEL BRACKET, WITH LOCK
WASHER & SPRING NUT
(3 FOR EACH CHANNEL)

I
I

'

TO UTI LilY-~~::>

'

"'\'
II
II
II

II ""'
TO LUMINAIRES- z_- flTlfilfl

II
\\

4.......___ 6 x 8 TREATED TIMBER

SERVICE CABINET MOUNTING DETAILS

~~1"

~~11

FRONT OF SERVICE CABINET

x 1/8" HOT DIPPED GALVANIZED STRAP

POST MOUNT
METAL WASHERS

NUT
PHOTOCELL
ENCLOSURE
FLANGE

3/8" Ill x 1" BOLT, LOCK WASHER


AND NUT. (TYP.)

SERVICE
CABINET

24"

=1~1"

--coNTROLLEft
:
CABINET

RIGHT SIDE OF SERVICE CABINET

2"

G)
CABINET BASE

POST, 10' LONG

RIGHT SIDE OF SERVICE CABINET

STRUT MOUNT

24"

..

~TO CONTROLLER CABINET

FRONT OF SERVICE CABINET

GROUND ROD

1 518" X 2 7/16" 12 GA.


SLOTTED STEEL CHANNEL
BRACKETS BOLTED TO
POST USE lWO - 3/8" BOLTS,
WASHERS AND NUTS
FOR EACH CHANNEL.
PEEN BOLT THREADS.

'"'::.':.':.~

ITb{ID

13" DIAMETER DRAIN TILE


WITH APPROVED COVER. (TYP.)

TO LUMINAIRES - - - - -

PLU MB CONDUIT 1"

in

GROUND ROD
(TYP.)

TO CONTROLLER
CABINET

1 5/8" X 1 5/8" 12 GA.


SLOTTED STEEL CHANNEL
BRACKETS BOLTED TO
POST USE lWO - 3/8" BOLTS,
WASHERS AND NUTS
FOR EACH CHANNEL.
PEEN BOLT THREADS.
(SEE SERVICE MOUNTING
DETAILS AND STRAP DETAIL)

'posT

CABINET BRACKET MOUNTING DETAIL

TO UTILITY _ _ _ __ j

BEVEL 1/2"

SLOTTED STEEL
CHANNEL BRACKET

#4 BARS
EACH CORNER

g--~_,

Co
._

TIMBER

II

ANCHOR
BOLT (TYP.)

~
::!!:

: 1'

1 5/8" X 2 7/16" 12 GA.


SLOTTED STEEL CHANNEL
BRACKETS (3 REQ'D), EMBED
12" MIN. IN FOUNDATION .

~EE ~OTE6

SERVICE CABINET BOLTED


TO SLOTTED STEEL CHANNEL
BRACKET (SEE SERVICE
CABINET MOUNTING DETAILS
AND STRAP DETAIL)

SEE STRAP DETAIL

1W0#4 HOOPS

II

1/4"

ANCHOR BOLT (TYP.)

POST MOUNT STRAP DETAIL

x 1" MACHINE BOLT

PHOTOCELL ENCLOSURE MOUNTING DETAIL

SEE STANDARD PLAN J-6c


"CABINET FOUNDATION DETAILS",
FOR DETAILS NOT SHOWN.

DRIVE GROUND RODS BEFORE PLACING


CONCRETE. MOVE ROD(S) AND DRAIN
TILE(S) WITH COVER(S) AS REQUIRED TO
ACHIEVE FULL GROUND PENETRATION.
MAINTAIN A 6' MINIMUM CLEARANCE
BElWEEN GROUND RODS AS DETAILED
ON STD. PLAN J-9a "TYPICAL GROUNDING
DETAILS".

#4 BAR EACH CORNER

G) GROUND ROD

PLAN VIEW OF SERVICE CABINET

ALL CONDUITS PENETRATING CABINET


SHALL BE TERMINATED WITH GROUNDING
END BUSHING AND BONDED TO THE
CABINET GROUNDING BUS.

G)

4" DIAM. x 1/2" DEEP SUMP. SLOPE


FOUNDATION TOWARDS SUMP. 3/8" DIAM.
POLYETHYLENE OR COPPER DRAIN PIPE.
SLOPE TO DRAIN OUTSIDE FOUNDATION.

TO SERVICE GROUND - PER STD. PLAN J-9a


"TYPICAL GROUNDING DETAILS"

1/4" x 2" STAINLESS STEEL BOLT


WITH 2 STAINLESS STEEL NUTS.
LIBERALLY COAT THIS ASSEMBLY
WITH ANTI OXIDANT COMPOUND.

1/8

BELLEVILLE
STAINLESS STEEL
SPRING WASHER

~---~

FILLET
WELD

CABINET - - - 1
SIDE WALL
1/8" X 1 1/4" X 1 1/4" X 6" ANGLE
ELEVATION VIEW

SIDE VIEW

CABINET MAIN BONDING JUMPER DETAIL

STAINLESS STEEL
FLAT WASHER
DETAIL A-A

SERVICE CABINET TYPE B


MODIFIED (0 200 AMP TYPE
120/240 SINGLE PHASE)
STANDARD PLAN .J-3b
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

------~s=~=T=Eo=E=SIG=N~EN=G~IN=EE=R------

fJ'I Washington

03-04-05
DATE

State Department of Transportation

CABINET WIDTH
PLUS 4"

KEY

GENERAL NOTES

--

200 AMP TYPE 120/240 11/J SERVICE CABINET


1. SEE STD. SPECIFICATION 9-29.24, SERVICE CABINETS.
8. ALL BUSSWORK SHALL BE HIGH GRADE COPPER AND
2. HINGES SHALL HAVE STAINLESS STEEL OR BRASS PINS.
SHALL EQUAL OR EXCEED THE MAIN BREAKER RATING.
ALL BREAKERS SHALL BOLT ONTO THE BUSSWORK.
4" DIAM. x 1/2" DEEP SUMP.
3. CABINETS SHALL BE RATED NEMA 3R AND SHALL
JUMPERING OF BREAKERS SHALL NOT BE ALLOWED.
SLOPE FOUNDATION
INCLUDE TWO RAIN TIGHT VENTS.
BUSSWORK SHALL ACCOMMODATE ALL FUTURE
TOWARDS SUMP. 3/8" DIAM.
EQUIPMENT AS SHOWN IN THE BREAKER SCHEDULE.
4.
METERING
EQUIPMENT DOOR SHALL BE PAD LOCKABLE.
POLYETHYLENE OR COPPER
EACH DOOR SHALL BE GASKETED. INSTALL BEST CX
9. THE PHOTOCELL UNIT SHALL BE CENTERED IN THE
DRAIN PIPE. SLOPE TO DRAIN
CONSTRUCTION CORE ON BOTTOM DOOR. SEE DOOR
PHOTOCELL ENCLOSURE TO PERMIT 360 DEGREE
OUTSIDE FOUNDATION.
HINGE DETAIL, STANDARD PLAN J-3b. CONCEALED
ROTATION OF THE PHOTOCELL WITHOUT REMOVAL
HEAVY DUTY STAINLESS STEEL LIFT OFF HINGES ARE
OF THE PHOTOCELL UNIT OR PHOTOCELL ENCLOSURE.
ALLOWED AS AN ALTERNATIVE TO DOOR HINGE DETAIL
SHOWN ON STANDARD PLAN J-3b. UPPER DOOR SHALL 10. ALL INTERNAL WIRE RUNS SHALL BE IDENTIFIED WITH
"TO - FROM" CODED TAGS LABELED WITH THE CODE
HAVE 2 HINGES AND LOWER DOOR SHALL HAVE 3
LETTERS AND/OR NUMBERS SHOWN ON THE SCHEDULES.
HINGES. THE LOWER DOOR SHALL HAVE A TWO
APPROVED PVC OR POLYOLEFIN WIRE MARKING SLEEVES
POSITION DOOR STOP ASSEMBLY.
SHALL BE USED.
5. THE FOLLOWING EQUIPMENT WITHIN THE SERVICE
ENCLOSURE SHALL HAVE AN APPROPRIATELY
11. ALL NUTS, BOLTS AND WASHERS USED FOR MOUNTING
ENGRAVED PHENOLIC NAME PLATE ATTACHED
THE PHOTOCELL ENCLOSURE SHALL BE STAINLESS STEEL.
12. A 1% TOLERANCE IS ALLOWED FOR ALL DIMENSIONS.
WITH SCREWS OR RIVETS:
' ''''
NOTE:
~ '
KEY NUMBERS 2, 3, 4, 6, 7, 8, 9, 16 AND 21.
13 THE PHOTOCELL CIRCUIT SHALL BE INSTALLED IN
''.
INSTALL FOUNDATION AS
KEY NUMBER 4 NAME PLATE SHALL READ:
.
''
"PHOTOCELL
BYPASS
TEST
ON"
AND
"PHOTOCELL
TEST
FLEX CONDUIT WITHIN THE METER COMPARTMENT.
SLAB SECTION UNLESS
OFF- AUTOMATIC". SEE SERVICE CABINET DETAIL.
14. INSTALL CONDUIT COUPLINGS ON ALL CONDUITS. PLACE
IDENTIFIED FOR CONSTCOUPLINGS FLUSH WITH TOP OF CONCRETE FOUNDATION.
RUCTION IN FENCE LINE
6. METERING ARRANGEMENTS VARY WITH DIFFERENT
IN CONTRACT PLANS.
4'-0"
15. SEE PLANS FOR BREAKER SCHEDULE.
SERVING UTILITIES. THE UTILITY MAY REQUIRE
METER BASE MOUNTING IN THE ENCLOSURE, ON
16. SEAL CABINET TO FOUNDATION WITH A 1/2" BEAD OF
FRONTAGE ROAD
MAINLINE
THE SIDE OR ON THE BACK OF THE ENCLOSURE. THE
SILICONE. APPLY SILICONE TO DRY SURFACE ONLY.
ROADWAY
UTILITY MAY REQUIRE THE DIMENSION BETWEEN
17.
THE
METER BASE PORTION OF THIS SERVICE WAS
SIDE VIEW
THE DOOR AND THE FRONT OF THE SAFETY SOCKET
DESIGNED TO MEET METERING PORTION OF EUSERC
INSTALLATION DETAIL
BOX TO BE LESS THAN THE 11 INCHES SHOWN IN THE
DRAWING 309 REQUIREMENTS.
LEFT SIDE- SAFETY SOCKET BOX MOUNTING DETAIL.
SEE STANDARD PLAN J-3b FOR SAFETY SOCKET
120/240VAC
BOX DETAIL. THE CONTRACTOR SHALL VERIFY THE
6"
SERVING UTILITY'S REQUIREMENTS PRIOR TO
2"
5~
FABRICATION OF AND INSTALLING THE SERVICE
EQUIPMENT.
12

PULL POSTS AS SHOWN


ON STD. PLAN L-2

SEE
DETAIL A
(TYP.)

'
":\:>:
''

2'-0"

~CJ

CABINET WIDTH
PLUS 18"

FRONT VIEW

'l

2'- 4"

6"

rc;~~1'-7"

7.
"SEE NOTE 6

....
('t)

I ~

DIMENSIONS SHOWN ARE MINIMUM AND SHALL BE


ADJUSTED TO ACCOMMODATE THE VARIOUS
SIZES OF EQUIPMENT INSTALLED.

14"

SEE
NOTE4

-<

BYPASS
TESTON

ILL CKT A

WITH FACTORY INSTALLED TEST BYPASS FACILITY THAT


MEETS THE REQUIREMENTS OF EUSERC DRAWING 305.

0 MAIN BREAKER (SEE BREAKER SCHEDULE)


PHOTOCELL BREAKER (SPST 15 AMP- 1201240 VOL1)
0 TEST SWITCH (SPDT SNAP ACTION, POSITIVE CLOSE, 15 AMP
-1201277 VOLT "T" RATED)

PHOTOELECTRIC CONTROL, STD. SPEC. 9 - 29.11 (2)


@
(j)

BRANCH BREAKER (SEE BREAKER SCHEDULE)


SIGNAL BREAKER (SEE BREAKER SCHEDULE)

CONTACTOR (SEE BREAKER SCHEDULE)


RECEPTACLE BREAKER (SPST 20 AMP- 1201240 VOL1)

@)
@
@

@
@
@

RECEPTACLE, GROUNDED (GFCI 20 AMP- 125 VOL1)


NEUTRAL BUSS, 14 LUG COPPER
PHOTOCELL ENCLOSURE- ENCLOSURE TO BE FABRICATED
FROM 518" EXPANDED STEEL MESH WITH WELDED SEAMS
AND MOUNTING FLANGES. HOT DIP GALVANIZED AFTER
FABRICATION. TYPE 5052- H32 ALUMINUM WITH 518" x 518"
OPENINGS EQUIVALENT TO 518" EXPANDED STEEL MESH
MAY BE USED AS ALTERNATIVE MATERIAL. SEE PHOTOCELL
ENCLOSURE MOUNTING DETAILS, STANDARD PLAN J-3b.
HINGED FRONT FACING DOOR WITH 4" x 4" MIN. POLISHED
WIRE GLASS WINDOW.
HINGED DEAD FRONT WITH 114 TURN FASTENERS OR SLIDE
LATCH.
CABINET MAIN BONDING JUMPER. BUSS SHALL BE 4 LUG
TINNED COPPER. SEE CABINET MAIN BONDING JUMPER
DETAIL, STANDARD PLAN J-3b.

@ SPARE BRANCH BREAKER (DPST 20AMP- 1201240 VOL1)


@ METAL WIRING DIAGRAM HOLDER
@ REMOVABLE EQUIPMENT MOUNTING PAN
@ 6" x 6" MIN. UNDERGROUND FEED- SERVICE WIREWAY
(LEFT REAR CORNER)
@SCREENED VENTS, 2 REQUIRED, 1 EACH SIDE, LOUVERED PLATES.

@ HEATER BREAKER (SPST 15 AMP- 1201240 VOL1)


@ THERMOSTAT, 40"F CLOSURE- 3 DIFFERENTIAL
@ STRIP HEATER (100 WATT NOMINAL), WITH TERMINAL STRIP COVER.
@ 24 CIRCUIT PANEL BOARD- MINIMUM SIZE WITH SEPARATE
MAIN BREAKER.

@ LABEL CABINET WITH BUSSWORK RATING.

CD METER
BASE PER SERVING UTILITY REQUIREMENTS. AS A
MINIMUM, THE METER BASE SHALL BE SAFETY SOCKET BOX

ILL CKT B
CONDUIT TO FENCE
POST BONDING POINT

#6 INSULATED STRANDED

FENCE POST

PHOTOCELL

FOUNDATION
SERVICE CABINET
1"

: ::DRAIN
~

-::

"

, ~--1- 1/2" x 12" BOLT


.....

"

'

::

-}

WITH 4" HOOK

SIDE VIEW

PLAN VIEW

TO UTILITY==~'
"
_))
" ~TO LUMINAIRES
TO CONTROLLER CABINET'-==To SERVICE GROUND PER STD. PLAN
FRONT VIEW J-9a "TYPICAL GROUNDING DETAIL"

SERVICE CABINET

SERVICE CABINET TYPE D


(0 200 AMP TYPE
OZ GEDNEY TYPE GC
BRONZE GROUND CLAMP 120/240 SINGLE PHASE)
OR EQUIVALENT (TYP.)
STANDARD PLAN .J-3c
CONDUIT

(MINUS FOUNDATION)

SIZE PER NEC.


MINIMUM SIZE #2

WIRING SCHEMATIC

DETAIL A

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Harold J. Peterfeso
_______

-~------=sT=~=E-DE-5-IG-NE-N-GI-NE-ER

fJ'I Washington

06-24-02
DATE

State Department of Transportation

~A

F oce of guordro i I

~Edge of shoulder

..

.. . : ...

J-box
N

================================================================================================

===j

G----e

Condu i t reserve oreo

'= ===.. =====================================-\___=


====================================================

l::::::::;::=:::::::;::::~==2:::!:::::;:.S].

Con d u i t

.,_.A
PLAN

2'

Condu i t
reserve
or eo

ELECTRICAL CONDUIT
PLACEMENT

SECTION A-A

STANDARD PLAN J-10


APPROVED FOR PUBLICATION

Clifford E. Mansfield
STATE DESIGN ENGINEER
~

Y411'

07-18-97
DATE

WASHINGTON STATE DEPARTMENT OF TRANSPORTATION


OLYMPIA, WASHINGTON

48 1/2"
13"

6" (TYP.)

0::

SERVICE FEEDER
CONDUIT LOCATION

f_

1. The cabinets shown in these details are shown for illustrative purposes only. The
Contractor shall verify the plans and substitute those cabinets in place of the cabinets
shown in these details. The Contractor shall install each cabinet type in the locations
and orientations shown in these details.

POLICE
PANEL

BACK

2. The Contractor shall install the conduits in the locations shown. Conduits shall extend
2" min. above the coupling. The conduit containing unfused utility conductors shall
extend into the utility chase.

UTILITY
GENERATOR
TRANSFER
SWITCH

SIGNAL
SIDE

II

NOTES

SERVICE
FEEDER
CONDUIT
LOCATION

2"MIN.
(TYP.)

52"

TYPED
SERVICE CABINET

TYPE 332D
CONTROLLER CABINET

4. The cabinets shall be attached to the foundation with 4 each: 1/2" x 12" x 2" x 4"
hot dip galv. anchor bolts, washers, and nuts. Stainless steel epoxy anchors may be
used as an alternative, and shall be 1/2" diam. x 9", or 5/8" diam. x 8". Bolts shall
extend 1 1/2" min. to 2" max. above the concrete pad.

TYPEE
SERVICE CABINET

5. All reinforcing steel shall be embedded 2" below surface of concrete.

24"
24"

44"

24"

6"
14"

3. The ground rods, drain tiles, associated conduits, and #4 rebar, goo with 30" legs, may
be omitted if no transformer or service cabinet is to be installed.

POLICE
PANEL

0C'l

~
.....

UTILITY
GENERATOR
TRANSFER
SWITCH

0C'l

~
.....

UTILITY
GENERATOR
TRANSFER
SWITCH

1"-

4 1/2"
(TYP.)

POLICE
PANEL

1"-

4 1/2"
(TYP.)

7. Two ground rods are required for foundations with a service cabinet
or transformer cabinet. See Standard Plan J-60.05 for details.

6"

6" (TYP.)

*UTILITY
GENERATOR
TRANSFER
SWITCH

6. Place a 1/2" bead of silicone between cabinets and foundation.

6"

~
.....

0C'l

POLICE
PANEL

9. Verify dead front locations from manufacturer prior to placing conduit


in foundation.

1"-

4 1/2"
(TYP.)

10. Foundations installed in, or adjacent to, sidewalks shall be constructed


with the top flush with the sidewalk surface and grade, not including
concrete risers for cabinets. Omit chamfers where foundation abuts
sidewalk.

FRONT

11. If the slope is 3H : 1V or steeper, special considerations may be


necessary for safety reasons. Coordinate with Maintenance and
Project Engineer.

TYPE 334
I

TYPE 333SD
CONTROLLER CABINET
*

TO BE INSTALLED BY REGION MAINTAINANCE


PERSONNEL. PROVIDE A 15' PIGTAIL.
(SEE NOTE 12)

CONSTRUCTION NOTES

G)

Drive ground rods before placing concrete. Move


rod(s) and drain tiles with cover(s) as required to
achieve full ground penetration. Maintain a 6'
minimum clearance between ground rods and 6"
from foundation edge as detailed on Standard
Plan J-60.05.

Install conduit couplings on all conduits. Place


couplings flush with top of concrete. If PVC
conduits are specified, the conduit stub and end
bell bushing shall not be glued to the coupling.

Cabinet power supply conduit.

(J)

Conduits for service grounding electrodes.

CAPACITY
CONDUIT
DIAMETER

SIZE
WxD
30"

TYPE 332

24"

TYPE332D

48.5"

NEMAP44

44"

26"

15"

TYPE333SD

44"

26"

48"~

TYPE 334

24"

30"

12"

30"

12"

UTILITY
GENERATOR
TRANSFER
SWITCH

POLICE PANEL

18"

12"

8"

24"

20"

12"

12.6 TO 35.0 KVA

32"

30"

15"

SIZE
WxD
16"

16"

15. The Police Panel location is set by Industry Standards on all Controller Cabinets.
16. See Standard Plan J-3b for Foundation Construction
and Conduit Routing for Type B Modified Service
Cabinet with Controller Cabinet.

18. Field bend #4 rebar around the Generator Anti-Theft


Tie Down Unit when required.

NEMA P44
CONTROLLER CABINET

19. See Standard Plan J-3c and J-3d for additional


details for Type D and Type E Service Cabinets.

7"

II

SIZE
WxD

UPTO 3 KVA

14. Use (1) #4 hoop for a 3 1/2" cabinet footing and (2) #4 hoops for a 9" cabinet footing.

17. Verify pad size and location with Project Engineer


prior to placing.

24"0

3.1 TO 12.5 KVA

332 CABINET
0

BACK

LOW VOLTAGE CONDUIT


PLACEMENT LOCATION

UNINTERRUPTABLE
POWER SUPPLY

The Type D Service shall not be installed on a


raised section. All other cabinets shall be installed
on 3 1/2" or 9" cabinet footing.

12. For Type 333SD Controller Cabinet, the cabinet vendor shall allow the Utility Transfer Switch to be
installed on either side of the cabinet. The Utility Transfer Switch unit shall be shipped inside the
cabinet for field installation by Region Maintenance Personnel.
13. Height of cabinet footings shall be adjusted to serve environmental needs. Adjust length of conduits
and rebar accordingly.

CONDUIT PLACEMENT
LOCATION AREA
(OR TRANSFORMER HIGH
VOLTAGE CONDUIT AREA)

TRANSFORMER

4" diam. x 1/2" deep sump. Slope foundation within


cabinet footprint toward sump. Drainpipe shall be
3/8" diam. polyethylene or copper tubing.

TYPE 332
CONTROLLER CABINET
44"

CONTROLLER OR
CABINET BASE

GRS conduits penetrating all cabinets shall be


terminated with grounding end bushing and bonded
to the cabinet grounding bus. All PVC conduits
penetrating cabinet shall be terminated with end
bell bushings.

TYPE 332 UNINTERRUPTABLE


POWER SUPPLY CABINET

*UTILITY
GENERATOR
TRANSFER
SWITCH

8. Concrete shall be class 3000. See Standard Specification 8-20.3(4).

DEAD FRONT

0::

f.
~

DEAD FRONT

7"

CABINET ORIENTATION
CONDUIT LAYOUT AND
FOUNDATION DETAIL
STANDARD PLAN J-10.10-01
SHEET 1 OF 5 SHEETS

DEAD FRONT

APPROVED FOR PUBLICATION


12"

12" OF CONDUIT IN EACH LOCATION SHOWN

~ 24" OF CONDUIT IN EACH LOCATION SHOWN

12.6 TO 35.0 KVA


TRANSFORMER

3.1 TO 12.5 KVA


TRANSFORMER

UPT03 KVA
TRANSFORMER

PLAN VIEWS
CABINET FOOTPRINT AND CONDUIT PLACEMENT LOCATIONS

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

CABINET
BASE

24"
6"MIN.
(TYP.)

CABINET
BASE

1"

24"

24"

1"

6"MIN.
(TYP.)

GENERATOR
ANTI-THEFT
TIE DOWN UNIT

1"

CABINET
BASE

6"

CABINET
BASE

6"

CABINET
BASE

24"
1"

20"

20"

GENERATOR ANTI-THEFT
TIE DOWN UNIT

SERVICE METER
BASE (TYP.)
- PREFERED
LOCATION WHEN
UTILITY REQUIRES
METER TO BE
MOUNTED ON
OUTSIDE OF
CABINET

POLICE PANEL

POLICE PANEL

ITS
SIDE

I
I

1-

Ww

UTILITY
GENERATOR
TRANSFER
SWITCH

I-

w w

UTILITY
GENERATOR
TRANSFER
SWITCH

Z(IJ

-<(

~m

~~
.....

=
.....

PLAN VIEW

PLAN VIEW
3/4" CHAMFER (TYP.)

3/4" CHAMFER (TYP.)


1/4" PREMOLDED
JOINT FILLER

1/4" PREMOLDED
JOINT FILLER
CONCRETE
ORHMA
MATERIAL

~~
CONTROLLER
CABINET

CONCRETE
ORHMA
MATERIAL

GROUND LINE

TYPEE
SERVICE CABINET

GROUND LINE

TO UTILITY

TO UTILITY

#4 HOOPSEE NOTE 14

ELEVATION VIEW

ELEVATION VIEW

THREE CABINET FOUNDATION


TWO CABINET FOUNDATION

(TYPE E SERVICE, 7.5 KVATRANSFORMERAND


TYPE 332 CONTROLLER CABINET SHOWN)

(TYPE D SERVICE AND TYPE 332D CONTROLLER CABINET SHOWN)


#4 REBAR - go WITH
30" LEGS (2 PLACES)

#4 REBAR - go WITH
30" LEGS (2 PLACES)

GENERATOR
ANTI-THEFT
TIE DOWN UNIT

TO
UTILITY

#4 REBAREACH CORNER
(SEE NOTE 18)

#4 HOOPSEE NOTE 14

TO
UTILITY

18" X 18" X 18"


DRAINAGE WELL
GENERATOR
ANTI-THEFT
TIE DOWN UNIT

--

/--

~n

:
I
I
I

CABINET ORIENTATION
CONDUIT LAYOUT AND
FOUNDATION DETAIL
STANDARD PLAN J-1 0.10-01

#4 REBAREACHCORNER
(SEE NOTE 18)

SHEET 2 OF 5 SHEETS

/
SPARE CONDUIT TO
ADJACENT JUNCTION BOX
- SEE CONTRACT PLANS

CONDUIT TO ADJACENT JUNCTION BOXSEE CONTRACT PLANS FOR NUMBER


AND SIZE OF CONDUITS (TYP.)

SPARE CONDUIT TO
ADJACENT JUNCTION BOX
- SEE CONTRACT PLANS

APPROVED FOR PUBLICATION


CONDUIT TO ADJACENT JUNCTION BOX___,__ _ SEE CONTRACT PLANS FOR NUMBER
AND SIZE OF CONDUITS (TYP.)

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

24"

CABINET
BASE

1"

CABINET
BASE

6"

CABINET
BASE

6"

CABINET
BASE

~ With Meter Base mounted

24"

1"

CABINET
BASE

24"

on inside of Service Cabinet,


allow 6" between cabinets

1"
..:.._

6"

CABINET
BASE

24"

- --=--

I-

1"

20"

0
I~
I

:::r
N

GENERATORANTI-THEFT --\
TIEDOWNUNIT

I~

w w

iii

C)

~ACK

UTILITY
GENERATOR
TRANSFER
SWITCH

I-

BACK

2
2 ~"

}--.

2~

ITIIIJ

"t
N

CONCRETE
ORHMA
MATERIAL

TYPE 332
UNINTERRUPTABLE
POWER SUPPLY
CABINET

TYPEE
SERVICE CABINET

GROUND
LINE

~~~~~~~~====~==~~~~~~~~~~~~~~;;;~~~k~

ELEVATION VIEW

FOUR CABINET FOUNDATION

--r=-=-=-==-=t_' ~~-~
i

!-------------------------~

:' i'

ELEVATION VIEW

(7.5 KVATRANSFORMERAND
TYPE 332 CONTROLLER CABINET SHOWN)

GENERATOR
ANTI-THEFT
TIE DOWN UNIT
(TYP.)

GENERATOR
ANTI-THEFT
TIE DOWN
UNIT

Ii

ii li: -:

, I' ,

#4 HOOPSEE NOTE 14

#4 REBAR EACH CORNER


(SEE NOTE 18)

:@Cf_f=_~-0~--~--ri

\-\_""' 18" X 18" X 18"


DRAINAGE WELL

''
''
'
!

'"=====----

#4 CORNER
REBAREACH
(SEE NOTE 18)

3/4" CHAMFER (TYP.)

TWO CABINET FOUNDATION

------::::,.____

SECTION

t
;._t

~~

#4 HOOPSEE NOTE 14

--~~~-- --~~=+---

SPARE CONDUIT TO ADJACENT


JUNCTION BOX (TYP.) - SEE
CONTRACT PLANS

C)

PLAN VIEW

-{,

:
I

TO UTILITY

iii

SPARE CONDUIT TO ADJACENT


JUNCTION BOX- SEE CONTRACT PLANS

18" X 18" X 18"


/
DRAINAGE WELL \ .
/
(TYP.)
~--/--

#4 HOOPSEE NOTE 14

I-

GROUND LINE

TO SERVICE CABINET

(TYPE 332 UNINTERRUPTABLE POWER SUPPLY CABINET, TYPE E SERVICE CABINET,


7.5 KVA TRANSFORMER AND NEMA P44 CONTROLLER CABINET SHOWN)

;._t

CONCRETE
ORHMA
MATERIAL

CONDUIT TO ADJACENT JUNCTION


BOX - SEE CONTRACT PLANS
FOR NUMBER AND SIZE OF
CONDUIT (TYP.)

#4 HOOP- SEE NOTE 14

#4 REBAR - go WITH
30" LEGS (2 PLACES)

6"MIN.
(TYP.)

1/4"PREMOLDED
JOINT FILLER

:::r
N

3/4" CHAMFER (TYP.)

TRANSFORMER

POLIC~ PANEL

UTILITY
. , - GENERATOR
TRANSFER
\
SWITCH

:::r
N

C)

6"MIN.
(TYP.)

PLAN VIEW
1/4" PREMOLDED
JOINT FILLER

r-----

FRO~

a:

POLICE
PANEL

-----

c.,
N

FRQNT

"

CONDUIT TO ADJACENT JUNCTION BOX - - - SEE CONTRACT PLANS FOR NUMBER


AND SIZE OF CONDUIT (TYP.)

#4 REBAR - go WITH
30" LEGS (2 PLACES)

SECTION

"""

CABINET ORIENTATION
CONDUIT LAYOUT AND
FOUNDATION DETAIL
STANDARD PLAN J-10.10-01
SHEET 3 OF 5 SHEETS

_j"""" "-

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

CABINET

~ Without transfer switch,

24"

24"

allow 6' between cabinets

1"

With transfer switch, allow


36" between cabinets.

CABINET
BASE

24"

{_

1"
18" X 18" X 18"
DRAINAGE WELL

HOT DIP GALVANIZED


AFTER FABRICATION

"

7 1/2" DIAM. BOLT CIRCLE


FOR AT LEAST 4 BOLT
HOLES@ 3/4" DIAM. EACH
PLAN VIEW

~~~=M~.~.~~~~~~~~
--'

~- GENERATOR
\__ANTI-THEFT
TIE DOWN UNIT

#4 REBAR-

w w

zen
<(

~co

1/4" STEEL PLATE


{TYP.)
(

......Noz~

PLAN VIEW
3/4" CHAMFER {TYP.)
CONCRETE
ORHMA
MATERIAL

PEDESTAL BASE DETAIL

1-

EACH CORNER
{SEE NOTE 18)
UTILITY GENERATOR
- - - TRANSFER SWITCH SEE SHEET 1 {TYP.)

CONDUIT TO ADJACENT
JUNCTION BOX - SEE
CONTRACT PLANS FOR
NUMBER AND SIZE OF
CONDUITS {TYP.)

0
u.

30" LEGS {2 PLACES)

1/4" STEEL
PLATE {TYP.)

3/8" POLYETHYLENE
DRAIN TUBE

::::>

#4 REBAR - go WITH

#6 REBAR
#3 REBAR
{TYP.)

TO SERVICE CABINET

SPARE CONDUIT TO
ADJACENT JUNCTION BOX
- SEE CONTRACT PLANS

TRANSFORMER

4" X 9"
PIPE FLANGE

PLAN VIEW
DRAINAGE
WELL

3/8" POLYETHYLENE
DRAIN TUBE
GRAVEL
BACKFILL

18" SQUARE
ELEVATION VIEW
(;\
CONCRETE
ORHMA
MATERIAL
1/4" PREMOLDED
JOINT FILLER

ISOMETRIC VIEW

SECTION~

GENERATOR ANTI-THEFT TIE DOWN UNIT

#4 HOOP-

(FABRICATE IF NOT AVAILABLE COMMERCIALLY)

SEE NOTE 14
ELEVATION VIEW
1/4" PREMOLDED
JOINT FILLER

TWO CABINET FOUNDATION


{7.5 KVATRANSFORMERAND
TYPE 333SD CONTROLLER CABINET SHOWN)

TO SERVICE CABINET

#4 HOOP- SEE NOTE 14

MAX.

ANCHOR BOLT

ELEVATION VIEW

SPARE CONDUIT TO
ADJACENT JUNCTION BOX
- SEE CONTRACT PLANS

336 STRETCH CABINET46" HEIGHT 24" WIDTH


22" DEPTH

#4 HOOP- SEE NOTE 14

'

{SEE NOTE4)

SINGLE CABINET FOUNDATION


{15 KVA TRANSFORMER SHOWN)

CONDUIT TO ADJACENT JUNCTION BOXSEE CONTRACT PLANS FOR NUMBER


AND SIZE OF CONDUIT {TYP.)

4" STEEL PIPE


- HOT DIP GALVANIZED

4" SLIPFITTER
3" X 5" HANDHOLE
WITH COVER

GENERATOR ANTI-THEFT
TIE DOWN UNIT
-SEE DETAIL

GENERATOR
ANTI-THEFT
TIE DOWN UNIT

CONCRETE OR
HMA MATERIAL

SLOPE TO
DRAIN {TYP.)

#4 VERTICAL REBAR
-8TOTAL

.....

CABINET ORIENTATION
CONDUIT LAYOUT AND
FOUNDATION DETAIL
STANDARD PLAN J-10.10-01
SHEET 4 OF 5 SHEETS

#4 BARS AT
#4 HOOP-

#4 REBAR - go WITH
30" LEGS {2 PLACES)

SECTION

ELEVATION VIEW

SEE NOTE 14

TYPICAL FOUNDATION CROSS SECTION


(SEE NOTE 12)

APPROXIMATELY
1' - 0" CENTERS

CONDUIT TO ADJACENT
JUNCTION BOX - SEE
CONTRACT PLANS FOR
NUMBER AND SIZE OF
CONDUIT {TYP.)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


-~------=sl~~~ED=E~SI=GN~E~NG=IN~EE=R~----

05-11-11
DATE

" ' Washington State Department of Transportation

PEDESTAL MOUNT

5"

UTILITY I GENERATOR
TRANSFER SWITCH

5"

POLICE PANEL

UTILITY I GENERATOR
TRANSFER SWITCH TO BE INSTALLED BY
REGION MAINTENANCE - - PERSONNEL. PROVIDE A
15' PIGTAIL (SEE NOTE 12)

UTILITY I GENERATOR
TRANSFER SWITCH
- INSTALL IN STANDARD
POLICE PANEL LOCATION

UTILITY I GENERATOR
TRANSFER SWITCH

UTILITY I GENERATOR
TRANSFER SWITCH

UTILITY I GENERATOR
TRANSFER SWITCH

POLICE PANEL

POLICE
PANEL

POLICE
PANEL

POLICE PANEL

Ill
FRONT VIEW

SIDE VIEW

SIDE VIEW

TYPE 332
CONTROLLER CABINET

TYPE 332
UNINTERRUPTABLE
POWER SUPPLY
(UPS) CABINET

SIDE VIEW

TYPE 3320 CONTROLLER CABINET

FRONT VIEW

SIDE VIEW

NEMA P44 CONTROLLER CABINET

FRONT VIEW

SIDE VIEW

TYPE 333SD CONTROLLER CABINET

GENERATOR
UTILITY I GENERATOR
TRANSFER SWITCH

AC-BUS
(NEUTRAL BUS)

GROUND BUS

I
I
I
I

ELECTRICAL
SERVICE OR
TRANSFORMER

PDA

I
I
I
I

SIGNAL
CABINET

LOAD

LINE
AC- f---___J

RADIO
INTERFERENCE
SUPPRESSOR

_l_

ACINPUT
TERMINAL
BLOCK

I I I

W G

I
~ I I I ~L____:

--------;------______]

____

II

CABINET ORIENTATION
CONDUIT LAYOUT AND
FOUNDATION DETAIL
STANDARD PLAN J-10.10-01

_j

SHEET 5 OF 5 SHEETS
APPROVED FOR PUBLICATION

TRANSFER SWITCH CONNECTION


TYPICAL WIRING DIAGRAM

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

12'- 0" MAX.

0::

PROVIDE A TYPE 4 CHAIN LINK


FENCE ON 3 SIDES WHEN
RETAINING WALL HEIGHT
EXCEEDS 4' - 0" - SEE
STANDARD PLAN L-20.10

2(j)- CONTINUOUS
AT TOP

NOTES
1. Contractor shall orient the maintenance pad to align with the direction
of natural grade as shown. Obtain Engineer's approval of maintenance
pad orientation prior to proceeding with construction.

ANCHOR BOLT (TYP.)


-SEE DETAIL

....1
(.)

3/4" CHAMFER (TYP.)


TOP OF MAINTENANCE
PAD

FINISHED
GROUND
LINE

2. The maintenance pad and retaining walls have been designed to meet
the requirements of the AASHTO LRFD Bridge Design Specifications
6th Edition, 2012.
3. Concrete for walls and bases shall be class 4000.

@-1'- 0" SPACING MAX.


(TYP.) EACH WAY

4. Height of wall varies to match slope of existing grade. Contractor shall


field determine wall height and each maintenance pad location and
obtain approval from the Engineer prior to proceeding with construction.

""'"

~ ~w

'
eo

w
en
SECTION

CONSTRUCTION JOINT
-OPTIONAL

5. 3/4" chamfer for all exposed corners.


6. For grounding details, see Standard Plan J-60.05.
7. For cabinet and conduit details not shown, see Standard Plan J-10.10.

9" RAISED CABINET PAD SHOWN, 3 1/2" RAISED CABINET


PAD SIMILAR WITH ONE #4 TOP HOOP
@- 1' - 0" SPACING MAX.
(EXTEND 8" MIN. INTO
MAINTENANCE PAD) (TYP.)

-1'- 0" SPACING


MAX. (TYP.)

SECTION

G)-1'- 0" SPACING


MAX. (TYP.)

CABINET PAD- SEE STANDARD


PLAN J-10.10 AND CONTRACT PLANS
FOR CABINET LAYOUT, CONDUITS
AND DRAINAGE DETAILS

FINISHED GROUND
LINE

FRACTURED FIN
FINISH

RETAINING WALL

10"

25'- 0" MAX.

10"

2@- CONTINUOUS
AT TOP

3/4" CHAMFER (TYP.)

8. The Cabinets shall be attached to the foundation with 4 anchor bolts and
located per the Cabinet supplier. Stainless steel epoxy anchor bolt may
be used as an alternative and shall be 1/2" diameter by 9" long.

RETAINING
WALL
FRACTURED
FIN FINISH

b
.....

L_~

3" FILLET
(TYP.)

@(TYP.)

MAINTENANCE
PAD

l
@(TYP.)

@(EXTEND 8" MIN. INTO


MAINTENANCE PAD)

SECTION

T~~~~~~~~~~~~~----~~~~~~~~r~~~~~~~~~~~~~~~~~~~~~~--~-1 r:~ i: :_- -_-_-_-_-_-_-_- _- _- _- -_-_-_-_- _- -_-_- ~:

c---!:::

.:

:
... -

!_______________________ __[_ _______________________


---:::-----

]!

3'- 6" FROM THE FACE

"

'----H---tt- OF WALL TO THE FACE

OF CABINET (TYP.)

--------

:::::J------

::::,......

I - .....

1/2"

REINFORCING STEEL BENDING DIAGRAM


SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAM.

VARIES
#5

&

I.

en
w

0::

::;

#4

G)#5
VARIES

ALL DIMENSIONS ARE OUT TO OUT

@
#4

I.

en
w

0::

::;

@&0#4
VARIES

VARIES
@&@#4

-lr

PLAN VIEW
CABINETS SHOWN FOR DISPLAY PURPOSES ONLY
SEE CONTRACT PLANS FOR CABINET LAYOUT

GROUNDING
DETAILS - SEE
STANDARD PLAN
J-60.05

CABINET ENCLOSURE
ON SLOPE
STANDARD PLAN J-10.15-00

.I

.I

Drive ground rods before placing concrete. Move rod(s)


and drain tile(s) with cover(s) as required to achieve full
ground penetration. Maintain a 6' - 0" minimum clearance
between ground rods as detailed on Standard Plan J-60.05.

ANCHOR BOLT
ASTM A307 WITH WASHER
AND NUT- GALVANIZED
PER MSHTO M 232

Limits of pigmented sealer. Typical for all retaining walls.

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


07102112
- - - -STATE
------DESIGN
ENGINEER
DATE

.....

. . . Washington State Department of Transportation

NOTES

,fD

T~}[
I.

::''.,

20

2. The requirement for a disconnect switch ahead of the Meter varies with different serving utilities. The Contractor
shall verify the serving utilities requirements prior to fabrication and installing the service equipment.

.I

52"

1. Metering Arrangements vary with different servicing utilities. The utility may require meter base mounting in the
enclosure, on the side, or on the back of the enclosure. The utility may require the dimension between the door
and the front of the safety socket box to be less than the 11" shown in the left side safety socket box mounting
detail, see Standard Plan J-3b. The Contractor shall verify the serving utility's requirements prior to fabrication
of and installing the service equipment.

PLAN VIEW

:~.1!:. :~olio.':~.~;.

;"4

3. See Standard Specification 9-29.24, Service Cabinets.


:z.".'

4. Hinges shall have stainless steel or brass pins.

"'.. :~:. .~~.

5. Cabinets shall be rated NEMA 3R and shall include two rain tight vents.
ELEVATION VIEW

SIDE VIEW

6. Metering equipment doors shall be pad lockable. Each door shall be gasketed. Install best construction core on
bottom left and right doors. See door hinge detail, Standard Plan J-3b. Concealed heavy duty stainless steel lift
off hinges are allowed as an alternative. Upper left door shall have 3 hinges, lower left door shall have 2 hinges,
and right door shall have 3 hinges. All doors shall have a two position door stop assembly.

SERVICE CABINET INSIDE RIGHT-OF-WAY


INSTALL FOUNDATION AS SLAB SECTION UNLESS IDENTIFIED
FOR CONSTRUCTION IN FENCE LINE IN CONTRACT PLANS

7. The following equipment within the service enclosure shall have an appropriately engraved phenolic name plate
attached with screws or rivets: Key number 2, 3, 4, 6, 7, 8, 9, 16, 21 and 24. Key number 4 name plate shall
read: "Photocell Bypass Test On" and "Photocell Test Off-Automatic". See Service Cabinet detail.

~< 1 FT OF
TINNED BRAIDED COPPER

# 8 AWG MIN.
BRONZE GROUND CLAMP WITH BRONZE U-BOLT,
WASHERS AND SET SCREWS

BRONZE GROUND
CLAMP (TYP.)

8. The dimensions shown are minimum and shall be adjusted to accommodate the various sizes of equipment
installed.
9. All busswork shall be high grade copper and shall equal or exceed the main breaker rating. All breakers shall
bolt onto the busswork. Jumpering of breakers shall not be allowed. Busswork shall accommodate all future
equipment as shown in the breaker schedule.

# 6 INSULATED
STRANDED

10. The photocell unit shall be centered in the photocell enclosure to permit 360 degree rotation of the photocell
without removal of the photocell unit or the photocell enclosure.
CONDUIT
BRONZE GROUND CLAMP WITH BRONZE U-BOLT,
WASHERS AND SET SCREWS

# 6 INSULATED
STRANDED

DETAIL

12. All nuts, bolts, and washers used for mounting photocell enclosure shall be stainless steel.
13. A 1% tolerance is allowed for all dimensions.
14. See plans for breaker schedule.
15. Install conduit couplings on all conduits. Place couplings flush with top of concrete foundation.

CONDUIT

SERVICE METER BASE OR


DISCONNECT SWITCH (TYP.) PREFERRED LOCATION WHEN
UTILITY REQUIRES METER OR
DISCONNECT SWITCH TO BE
MOUNTED ON OUTSIDE OF
CABINET

11. All internal wire runs shall be identified with "To-From" coded tags labeled with the code letters and/or numbers
shown on the schedules. Approved PVC or Polyolefin wire marking sleeves shall be used.

DETAIL
--""""=':----

16. Seal cabinet to foundation with a 1/2" bead of silicone. Apply silicone to dry surface only.

TYPE 3 CHAIN LINK FENCE (TYP.) SEE STANDARD PLAN L-20.10

17. The meter base portion of this service was designed to meet metering portion of Euserc Drawing 309
requirements.
TYPE 3 CHAIN LINK FENCE (TYP.) SEE STANDARD PLAN L-20.10

END OR CORNER POST (TYP.) SEE STANDARD PLAN L-20.10

END OR CORNER
POST (TYP.) SEE STANDARD
PLAN L-20.1 0

CHAIN LINK GATE- SEE


STANDARD PLAN L-30.10

&>
'

.----Mr--7----~

3'- 6"

-,

1------'-----i---~: :

'< ~~~~~~-::..0:..::.~

6' CHAIN LINK GATE'"""SEE STANDARD


''"~ '"~...
PLAN L-30.10

SERVICE CABINET TYPE E


(0 - 200 AMP TYPE 240/480
SINGLE PHASE
STANDARD PLAN J-10.22-00

'""""""""""""'..:::-..:::-

PLAN VIEW

2411

SHEET 1 OF 2 SHEETS
I

ELEVATION VIEW

SIDE VIEW

APPROVED FOR PUBLICATION

I (TYP.) I

SERVICE CABINET WITHIN RIGHT-OF-WAY FENCE


FOR CONDUITS NOT SHOWN, DRAIN TILE FOR GROUNDING, DRAIN TUBES, REINFORCING STEEL, ETC.
OMITTED FOR CLARITY, SEE STANDARD PLAN J-10.10 FOR DETAILS.

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

KEY

CD

2'- 0"

2"
--=--

Meter base per serving utility requirements. As a minimum,


the meter base shall be safety socket box with factory
installed test bypass facility that meets the requirements of
Euserc Drawing 305.
Photocell Breaker (SPST 15 AMP- 120/240 volt).

CD

Test With (SPOT snap action, positive close 15 AMP120/277 volt "T" rated).

Photoelectric Control, Standard Specification 9-29.11 (2).


Branch Breaker (see Breaker Schedule).

(j) Signal Transformer Breaker (see Breaker Schedule).

PRIMARY DISCONNECT
AHEAD OF METERBASE

'

'

TillS IS A
MOLDED CASE SWITCH
IT IS NOI AN AUTOMATIC TRIP
CIRCUIT BREAKER

LABEL"A"

PHOTOCELL BYPASS
TEST ON

PHOTOCELL TEST
OFF-AUTOMATIC
WARNING

240 /480.VAC
DISCONNECT SWITCH
-SEE NOTE 2

Contactor (see Breaker Schedule).


Receptacle Breaker (SPST 20 AMP- 120/240 volt).

'

__

'

Co

~JJ. l<.
I

C\1

""
'
'
'

Potential
Arc Flash
Hazard

'

'
'
'

LABEL"B"

"''"
"'"

@) Receptacle, Grounded (GFCI 20 AMP- 125 volt).

2"

@ Main Breaker (See Breaker Schedule).

2'- 4"

Neutral Buss, 14 lug copper with stainless steel Allen head


screws.

,.....

@ Photocell Enclosure - enclosure to be fabricated from 5/8"


expanded steel mesh with welded seams and mounting
flanges. Hot dip galvanized after fabrication. Type 5052 - H32
aluminum with 5/8" x 5/8" openings equivalent to 5/8" expanded
steel mesh may be used was alternative material. See
Photocell Enclosure Mounting details, Standard Plan J-3b.

@ Hinged front facing door with 4"

BYPASS
TEST ON

PHOTOCELL

x 4" min. polished wire

copper. See Cabinet Main bonding Jumper detail,


Standard Plan J-3b.

TEST
OFF AUTOMATIC

'

C\1

ILL CKT B

Metal Wiring Diagram Holder.

@ Removable Equipment Mounting Pan.


@) 6" x 6" min, underground feed - service wire-way (left rear

.........

..........

@ Spare Branch Breaker (DPST 20 AMP- 240/480 volt).

-f-

ILL CKT A

glass window.

@ Hinged dead front with 1/4 turn fasteners or slide latch.


@ Cabinet Main Bonding Jumper. Buss shall be 4 lug tinned

........

PHOTOCELL

ILL CKT C

/..J

f_\

!>

!>

,':-

,':-

.'-'

,':-

-~

..~

'

!> .

.~

.'~'
I>

,':-

_,_,
.'~\

I>

-'-'
-~

corner).

@ Heater Breaker (SPST 15 AMP- 120/240 volt).

FOUNDATION DETAILS- SEE _ /


STANDARD PLAN J-10.10

Screened Vents, 2 required, 1 each side, louvered plates.


ILL CKT D

SERVICE CABINET DETAILS

Thermostat, 40F closure 3 differential.

@ Strip Heater (100 watt nominal), with terminal strip cover.

Transformer Breaker (DPST 15 AMP- 480 volt).

@ Dry Transformer (480/120 volt) 3 KVA copper

ILL CKT E

bussed and copper wound.

@ Reserved for meter, current transformer and/or disconnect


switch as required by the utility.

24 circuit panel board - minimum size with separate main


breaker.

@ Label Cabinet with Buss work rating.


@ 6 Circuit Panel Board - minimum size.

>

Molded Case Switch, Rating of switch shall equal or exceed main breaker rating.
Provide landing lugs rated to accept 350 Kcmil conductors. (Omit if utility requires
the disconnect switch to be mounted externally, or if the utility does not require
the disconnect switch).

@ Molded case switch standoff bracket. (Omit if utility requires the disconnect switch to be
mounted externally, or if the utility does not require the disconnect switch).

Molded case switch enclosure with cover. (Omit if utility requires the disconnect switch to
be mounted externally, or if the utility does not require the disconnect switch).

WIRING SCHEMATIC

SIZE PER NEC.


MINIMUM SIZE # 2

SECTION

SERVICE CABINET TYPE E


(0 - 200 AMP TYPE 240/480
SINGLE PHASE
STANDARD PLAN J-10.22-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


-~----~s=~=TE~D=Es=IG~N=EN=G~INE-ER
_____ _

5129113
DATE

. . . Washington State Department of Transportation

~--------~8)~------~1

NOTES
1. Timber luminaire supports are allowed only for temporary
installations where breakaway or slip bases are not required.
2. When down guys are required, See Standard Plan J-15.15.

2 UNITS

PLAN VIEW
LUMINAIRE SUPPORT BRACKET

3 UNITS

11

DETAIL

0
1/4

30

29

4 UNITS

22
1/4" PLATE
w

lfj ;;r~

lfj ;;r~

~1-

en
I

~1-

a::

en

~ 1cnz
00

b::

o ll.!z

c cnz

C<C

___,_Iii_ _ _ _ _ _

j<=1

TIMBER LUMINAIRE SUPPORT

D _______

PLAN VIEW
TYPICAL LUMINAIRE MOUNTING
CONFIGURATIONS

w {)

LlJ II.

L______j

6 UNITS

a::

~ 1cnz
00

b:: w {)
LlJ II. 0

GUSSET DETAIL

ci<C

____:L_t;

HIGH MAST TIMBER


LUMINAIRE SUPPORT

TIMBER LUMINAIRE SUPPORT

SHOWN FOR 480 VAG POWER FEED.


INCREASE CONDUCTOR AND FUSE SIZE
AS REQUIRED FOR 240 VAG POWER FEED.

KEY

G)
(D
G)

GALVANIZED STEEL OR ALUMINUM MAST ARM -CONFIGURATIONS VARIES WITH MANUFACTURER


LUMINAIRE - SEE CONTRACT FOR TYPE AND NUMBER
MOUNTING HEIGHT- ROADWAY TO LUMINAIRE ELEVATION DIFFERENCE 2%- SEE CONTRACT

8) MAST ARM LENGTH - SEE CONTRACT


@
@
(j)
@
@

5/8" GALVANIZED THIMBLE EYE BOLT (SINGLE OR DOUBLE) WITH WASHERS AND NUTS OR EYENUT
BONDING JUMPER
POLE AND BRACKET CABLE

@
@

8" x 8" x 4" NEMA 3R JUNCTION BOX WITH RAIN-TIGHT HUBS AND REMOVABLE COVER

@)

GROUNDING LUG

@
@
@

DIRECT BURIAL CONDUCTORS OR GALVANIZED STEEL CONDUITS WITH CONDUCTORS- SEE CONTRACT

STEEL CONDUIT

12 POLE TERMINAL BLOCK


GROUNDING BUSHING

SUPPLEMENTAL GROUND - SEE STANDARD PLAN J-60.05

FROM GROUND LINE TO 10' ABOVE GROUND, ENCLOSE EQUIPMENT GROUNDING CONDUCTOR IN
GALVANIZED STEEL CONDUIT, CODE SIZED. ABOVE 10' FROM GROUND, STAPLE EQUIPMENT GROUNDING
CONDUCTOR TO POLE. CONNNECT TO SUPPLEMENTAL GROUND, PER STANDARD PLAN J-60.05

@
@
@

CLASS 5 TIMBER POLE - LENGTH SUFFICIENT FOR MOUNTING HEIGHT AND BURIAL DEPTH

SERVICE WEDGE CLAMP

3/8" x 4" MACHINE BOLTS (FOUR REQUIRED) WITH WASHERS AND NUTS

@
@
@
@
@

ACSR TRIPLEX OR FOURPLEX CONDUCTORS - SEE CONTRACT

1/2" LAG BOLTS (SIX REQUIRED) -DRILL 9/16" HOLE IN PLATE


3/4" WIRE HOLE 2" FROM GUSSET PLATE, SMOOTH HOLE EDGES

FUSED QUICK DISCONNECT, PER STANDARD SPECIFICATION 9-29.7- USE 30 AMP FUSES FOR HIGH MAST SUPPORTS

@
@
@
@
@

@)

WEATHERHEAD- SIZE AS REQUIRED

@)

CONDUIT GROUND CLAMP

EQUIPMENT GROUNDING CONDUCTOR - SEE STANDARD PLAN J-60.05

CU \ AL SPLIT BOLT CONNECTOR


MESSENGER CABLE
INSULATING TAPE FOR WATERPROOF CONNECTION

TIMBER LIGHT STANDARD

CLASS 2 TIMBER POLE - LENGTH SUFFICIENT FOR MOUNTING HEIGHT AND BURIAL DEPTH
1/4" x 10" PLATE COLLAR BENT TO FIT POLE DIAMETER (8"- 10")

STANDARD PLAN J-15.10-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

2" PIPE
1" NON-METALLIC CONDUIT WITH 1" STRAPS SPACED MAXIMUM 5' APART AND NEAR ALL CONDUIT ENDS
DISTANCE VARIES, 35' MIN. TO 50' MAX. DEPENDING ON LINE CLEARANCE REQUIREMENTS

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

05118112
DATE

. . . Washington State Department of Transportation

....1

....1

5
~

ffi

POLE ~

GUY WRAP (TYP.)


-SEE NOTE 4

-l

5/8" STRAIGHT STRAND EYE BOLT WITH


2 1/2" SQUARE CURVED WASHER
AND (2) HEX NUTS

STRAIN
INSULATOR
-SEE DETAIL

NOTES

5i=
RAKE POLE AND INSTALL DOWN GUY
ASSEMBLY BEFORE LOADING

>

RAKE POLE
BEFORE LOADING

- SEE RAKE TABLE

- SEE RAKE TABLE


WEATHERHEAD
ENTRANCE ELBOW

r-

1. An eight-way expanding anchor may


be used as an acceptable alternate to
power installed helical screw anchor.
2.

If anchor hole diameter is greater than


nominal diameter of folded anchors, a
5' cover of 6" to 12" size rock shall be
tamped in to replace the disturbed soil
immediately above the anchor.

3.

See Standard Plan J-7c for Type IV


or Type V Strain Pole details not
shown.

4.

Strandvise or Guy Wrap may be used.

BONDING LUG

4'- 0" MIN.

5/8" ANGLE STRAND EYE BOLT WITH TWO-HOLE


LIFT PLATE, 1/2" LAG BOLT, 2 1/2" SQUARE CURVED
WASHER AND DOUBLE HEX NUTS (DOUBLE EYE
BOLT FOR MULTIPLE GUYS) (TYP.)

POLE

6'- 0" MAX.

SAG = 5% OF SPAN
LAG LENGTH 1%
GROUND
CLAMP

GROUND CLAMP
GROUND
CLAMP
STRAIN INSULATOR
-SEE DETAIL
GUY
STANDOFF

TOP OF ALL
SIGNAL HEADS
IN LEVEL LINE

BOND WIRE

BACKPLATE WITH
RETROFLECTIVE
TAPE

GALVANIZED STEEL BAR


- 2" DIAM. 12 GAUGE
AERIAL TERMINAL COMPARTMENT
ASSEMBLY - ON SPANS NOTED IN
THE CONTRACT

8' - 0" YELLOW REFLECTIVE


PLASTIC GUY GUARD

6'- 0"

STRANDVISE (TYP.)
-SEE NOTE 4

8' - 0" YELLOW REFLECTIVE


PLASTIC GUY GUARD

GUY WRAP

RAKE TABLE

SEE TIMBER STRAIN POLE


FOR DETAILS NOT SHOWN

DOWN GUY
DETAIL

40' CLASS 2 TIMBER POLE, MIN.


- UNLESS NOTED OTHERWISE
IN THE CONTRACT

POLE CLASS

RAKE

1900#

7"

2700#

6"

3700#

5"

4800#

5"

5400#

4"

4300#

4"

7200#

4"

ALL TIMBER

6"

SEE SIGNAL DISPLAY


VERTICAL CLEARANCE
CHART

WIRE ROPE THIMBLE (TYP.)


TOP OF
ROADWAY

FINISHED GRADE

FINISHED GRADE

TYPE IV OR TYPE V
STRAIN POLE STANDARD

COMPACTED PIT RUN ROCK- 6" TO 12" IN ACCORDANCE


WITH STANDARD SPECIFICATION 2.09-3(1)E

ALTERNATE DOWN
GUY DETAIL

(SEE NOTE 3)

(WITH GUY WRAPS SHOWN)

SIGNAL DISPLAY VERTICAL CLEARANCE TO ROADWAY


POWER INSTALLED
HELICAL SCREW
ANCHOR - SEE NOTES

TIMBER STRAIN POLE


PLAN
POWER INSTALLED
HELICAL SCREW
ANCHOR - SEE NOTES

''
''
'',
'

ANCHOR ASSEMBLIES
(SEE STANDARD SPECIFICATION 9-29.4)

(WITH STRANDVISE SHOWN)


''
''

'

ELEVATION

-- ---

i'

'

'\!

SIDE VIEW

STRAIN INSULATOR DETAIL

HORIZONTAL DISTANCE
FROM STOP LINE

40'

45'

50'

53' -180'

MIN.

MAX.

MIN.

MAX.

MIN.

MAX.

MIN.

MAX.

3 SECTION 12"
5 SECTION DOGHOUSE 12"

16.5'

17.5"

16.5'

19.2'

16.5'

20.9'

16.5'

22.0'

4 SECTION 12"

16.5'

17.0'

16.5'

18.0'

16.5'

19.7'

16.5'

20.8'

5 SECTION 12"

16.5'

17.0'

16.5'

17.5"

16.5'

18.5'

16.5'

19.6'

SPAN WIRE
INSTALLATION
STANDARD PLAN .J-15.15-00
SHEET 1 OF 1 SHEET

MEASURED FROM BOTTOM OF


SIGNAL HEAD HOUSING TO ROADWAY

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-10
DATE

. . . Washington State Department of Transportation

3" PIPE CAP

NOTES

3" PIPE CAP

STAINLESS STEEL
FLAT WASHER (TYP.)

1.
TOP OF POST

(3) 1/4" STAINLESS


STEEL HEX NUTS

See Standard Plan J-20.26 for Accessible Pedestrian Pushbutton details.

2. Pole shall be galvanized per MSHTO M111.


3. When additional crossing time is needed, install plaque (R10-32P) "PUSH BUTTON FOR 2 SECONDS

1/4" X 1-1/4" LONG


STAINLESS STEEL
THREADED STUD

FOR EXTRA CROSSING TIME" above the Accessible Pedestrian Signal assembly. Add 14" to post to
accommodate plaque and leave a 2" space between signs.

(o

.....

GROUNDING CONNECTION SEE DETAIL AT LEFT

0;
0

4. Mounting distances vary between manufacturers. See manufacturers recommendations for mounting information.

EQUIPMENT GROUNDING ---++--.oi~


CONDUCTOR

SUPPLEMENTAL GROUNDING
CONDUCTOR AND FULL CIRCLE
CRIMP-ON CONNECTOR - CRIMPED
WITH A MANUFACTURER'S
RECOMMENDED CRIMPER

5. Junction Box serving the Standard shall preferably be located 5'- 0" (10'- 0" Max.) from the Standard.
""'w"

I-

FIELD DRILL AND TAP FOR


1/4-20 THREAD BOLT (TYP.)

PIPE CAP

w
w

en
GROUNDING CONNECTION
DETAIL

ACCESSIBLE PEDESTRIAN
PUSHBUTTON(PPB)ASSEMBLY

*WELD STUD TO POLE WALL TO


MAXIMUM EXTENT POSSIBLE
(1/2" MINIMUM WELD)

10" OR LESS DESIRABLE18" MAXIMUM

1 1/2" DIAMETER
HOLE

5/8" DIAMETER
HOLE (TYP.)

5/8" DIAMETER
HOLE
M

POST DETAIL
6" DIAMETER
BOLT CIRCLE

1/4" STEEL
PLATE

in,

(o

= en

EDGE OF
SIDEWALK

"

....1

ll.

1\

''

I!

1/2" STEEL
BASE PLATE

5/8" DIAMETER
HOLE (TYP.)

II

:c..= ""'"

i't>

BASE PLATE ASSEMBLY1/2" DIAMETER STEEL HEX NUT, WITH


1 1/2" FLAT WASHER (2) EACH REQ'D
PER ANCHOR BOLT - MINIMUM OF (2)
THREADS ABOVE TOP OF NUT OR
5/8" MAXIMUM (TYP.)

7"

z
btl:j
en

PEDESTRIAN PUSHBUTTON POST 3" STEEL PIPE (SCHEDULE 40)

ANCHOR BOLT TEMPLATE

3/4" CHAMFER (TYP.)


6" DIAMETER
BOLT CIRCLE

TOP OF FOUNDATION
3/8" PREMOLDED JOINT FILLER
3/8" PREMOLDED
JOINT FILLER

FINISHED GRADE

FINISHED
GRADE

,,

3 9/16" DIAMETER
HOLE

II

l1

II

:~

--

111

I I
II I

BASE PLATE DETAIL

(o

BASE PLATE ASSEMBLY1/2" DIAMETER STEEL HEX NUT,


WITH 1 1/2" FLAT WASHER, (2) EACH
REQ'D. PER ANCHOR BOLT - MIN.
OF (2) THREADS ABOVE TOP OF
NUT OR 5/8" MAXIMUM (TYP.)

:~

ANCHOR BOLT TEMPLATE ASSEMBLY

::

::

:1

ANCHOR BOLT TEMPLATE- (2) REQUIRED

17

1/2" x 18" FULL THREAD ANCHOR BOLT(4) REQUIRED PER ASSEMBLY

I li

Ill
!:
I I ::

....'

--

[>'

l1

II

Ill
;:
I I 1:

&>

EQUIPMENT GROUNDING
CONDUCTOR

r ii

----{}-T-L"f--.$-----

3" STEEL PIPE


(SCHEDULE 40)

1/2" STEEL PLATE

ll-,-

:: Ill ::

II I

::

I I
I' I

"

1/2" HEX NUTS- (4) REQUIRED PER


ANCHOR BOLT

-----;---rrt--;=-----~
"

FLAT WASHERS, ASTM F 436- (4) REQUIRED


PER ANCHOR BOLT

Ill
I I

1/2" STEEL BASE PLATE

I, I

l>

COMMERCIAL CONCRETE

GROUT PADINSTALL AFTER


PLUMBING STANDARD

...

ACCESSIBLE PEDESTRIAN
PUSHBUTTON POST (PPB)
AND FOUNDATION
STANDARD PLAN J-20.10-02

3/8" DRAIN TUBE

C>'

. t>

DETAIL

0,

"V

ELEVATION

1 1/2" (TYP.)
1" DIAMETER
ELECTRICAL
CONDUIT

I"-

. t>

6"

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

1' - 6"

Pasco Bakotich Ill

SQUARE

FOUNDATION DETAIL

PERSPECTIVE VIEW

......

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

TOP OF POST

3" PIPE CAP


=-=-::::lll;,o;_

NOTES

_L_

GROUNDING CONNECTION SEE DETAIL

1. All poles shall be hot dip galvanized per AASHTO M 111.

Co
.....
a;
co
.....

ACCESSIBLE PEDESTRIAN

PUSHBUTION (PPB) ASSEIMBLy

2.

Supplemental grounding conductor shall be non-insulated #4 AWG stranded copper and shall be clamped to vertical
rebar with a connector suitable for use embedded in concrete: provide 3' - 0" min. slack. Attach to pole grounding
stud with a full circle crimp-on connector (crimped with a manufacturer's recommended crimper) .

3.

See Standard Plan J-20.26 for Accessible Pedestrian Pushbutton details.

4. When additional crossing time is provided by an extended pushbutton press, a "PUSH BUTTON FOR 2 SECONDS
FOR EXTRA CROSSING TIME" plaque (R10-32P) shall be installed above the Accesible Pedestrian Signal assembly.
Leave a 2" space between signs.

co
FIELD DRILL AND TAP FOR
1/4-20 THREAD BOLT TYP.)

5.

7"

~ OF PUSHBUTTON

PIPE CAP

1/2" STEEL
PLATE

1 1/2" CLR.
(TYP.)

5/8" DIAMETER
HOLE

bz

6" DIAMETER
BOLT CIRCLE

lh

1/4" STEEL
PLATE

""'w

SQUARE

PLAN VIEW

STAINLESS STEEL
FLAT WASHER (TYP.)

TOP OF POST

5/8" DIAMETER
HOLE (TYP.)

1'- 6"

1 1/2" DIAMETER
HOLE

5/8" DIAMETER
HOLE (TYP.)

1/4" X 1-1/4" LONG


STAINLESS STEEL
THREADED STUD

C.tlJ
-'
LO

C/)

II

POST WALL

= &>

~C/)
::::>

3 9/16" DIAMETER
HOLE

D..

3" STEEL PIPE


(SCHEDULE 40)

6" DIAMETER
BOLT CIRCLE

GROUNDING CONNECTION
DETAIL

BASE PLATE DETAIL

FINISHED
GRADE

ANCHOR BOLT TEMPLATE


TOP OF
SIDEWALK

3/4"
CHAMFER

EQUIPMENT GROUNDING
CONDUCTOR

3/16
1/2" STEEL BASE PLATE
1/2" BASE PLATE
-SEE DETAIL

. .

..

. .

GROUT PAD - INSTALL


AFTER PLUMBING
STANDARD

ANCHOR BOLT TEMPLATE ASSEMBLY


ANCHOR BOLT TEMPLATE- (2) REQUIRED
1 1/2" CLR.
(TYP.)

1/2" HEX NUTS- (4) REQUIRED PER


ANCHOR BOLT

ELECTRICAL CONDUIT

1' - 6"

FLAT WASHERS, ASTM F 436(4) REQUIRED PER ANCHOR BOLT

'I

=
0:::
v...J

VIEW0

. .. IIII

1,1

i I:

IIII

,~

TOP OF
SIDEWALK

Ill
II
II
Ill
II
Ill

I' I
111

I>

I>
I>

1 1

I I
1,1
I I

SECTION
ANCHOR BOLT
TEMPLATE ASSEMBLY

- - "~+-~~l_-4~"
I' I I l'

ACCESSIBLE PEDESTRIAN
PUSHBUTTON WITH
CURB BASE
STANDARD PLAN J-20.11-01

11

1'- 6"

1" DIAMETER
ELECTRICAL
CONDUIT

#4

6"

I>

3/8" PREMOLDED JOINT FILLER

Ill
II
II
Ill
II
Ill

I I

SEE STD. SPEC. 9-07.1(2)


FOR BENDING DIAMETERS

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

..........J

Pasco Bakotich Ill

1'- 6"

ELEVATION
DIMENSIONS ARE OUT TO OUT

~ 1- - "~1f-~~~f=--t-"
II 1 1 II

REINFORCING STEEL BENDING DIAGRAM

I,

{)

.. ~ I
"

v I

14 3/4"

CONFIGURATIONS VARY AMONG DIFFERENT MANUFACTURERS

1 1/2" (TYP.)

I>

SQUARE

WELD STUD TO POLE WALL TO MAXIMUM EXTENT


POSSIBLE - 1/2" MINIMUM WELD

3/8" DRAIN TUBE

ANCHOR BOLT 1/2" x 26" FULL THREAD(4) REQUIRED

1" DIAMETER

BASE PLATE ASSEMBLY1/2" DIAMETER STEEL HEX NUT, WITH


1/2" FLAT WASHER, (2) REQUIRED
PER ANCHOR BOLT - MINIMUM OF
(2) THREADS ABOVE TOP OF NUT
rh~~""""""OR 5/8" MAXIMUM (TYP.)

1 1/2" CLR.
(TYP.)

(3) 1/4" STAINLESS


STEEL HEX NUTS

SUPPLEMENTAL GROUNDING
CONDUCTOR AND FULL CIRCLE
CRIMP-ON CONNECTOR - CRIMPED
WITH A MANUFACTURER'S
RECOMMENDED CRIMPER

....1

8 5/8"

1/2" RADIUS
(TYP.)

Junction Box serving the Standard shall preferably be located 5'- 0" (10'- 0" Max.) from the Standard.

TYPE PPB STANDARD DETAILS

......

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

1'- 0"

6"
(TYP.)

l_

;._

6" DIAMETER HOLLOW IN


CENTER OF GROUT PAD

1 1/2"

0:::
0

LL.

>-

()

<(

en

(c

::::i

>
m

1/4-20 (TYP.)

~Jj_

~
.....

ib

QzfD
EQUIPMENT GROUNDING
CONDUCTOR
GROUNDING CONNECTION SEE STANDARD PLAN J-20.20

0
It)

""

ib

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 2

ib

ib

BASE PLATE ASSEMBLY -

3/4" DIAMETER STEEL HEX NUT,


WITH FLAT WASHER, (2) EACH REQ'D
PER ANCHOR BOLT- MINIMUM OF
(2) THREADS ABOVE TOP OF NUT
OR 5/8" MAXIMUM (TYP.)

1/2" STEEL BASE PLATE SEE DETAIL

It)

r-.:

I.

GROUT PAD - INSTALL AFTER


PLUMBING STANDARD

2'- 0"

);~=fFft=~;;a.___

SQUARE

LEVELING NUT (TYP.)

# 4 (TYP.)
3/8" I. D. DRAIN TUBE
IN GROUT PAD

0.90" DIAMETER

PLAN VIEW

HOLE

FOUNDATION DETAILS

TOP OF FOUNDATION
TOP OF SIDEWALK

0.31" DIAMETER
HOLE

9"

1" DIAMETER
HOLE (TYP.)

DUEL(APS)ASSEMBLY
MOUNTING ADAPTER
DETAILS
TYPE 1 SIGNAL POLE
ACCESSIBLE PEDESTRIAN PUSHBUTTON
WITH DUEL ASSEMBLY MOUNTING
ADAPTER (TYP.)
b

9" DIAMETER
BOLT CIRCLE

REINFORCING STEEL
QUANTITIES LIST
1/4" STEEL

QTY.

9" DIAMETER
BOLT CIRCLE

TYPE 1 SIGNAL POLE

MARK

PLATE

HOLE (TYP.)

\_
I

@#4

BASE PLATE DETAIL


1" DIAMETER

1/2" STEEL PLATE WITH


HOLE= POLE BASE+ 1/6"

3/8" PREMOLDED
JOINT FILLER

I
I

SUPPLEMENTAL GROUNDING
CONDUCTOR CLAMP SEE NOTE 2

ELECTRICAL CONDUIT - SEE


CONTRACT PLANS FOR DIAMETER

CONDUIT COUPLING - INSTALL


FLUSH WITH TOP OF FOUNDATION
ANCHOR BOLT

~
'{J

SECTION

TOP OF
FOUNDATION

ANCHOR BOLT TEMPLATE


REINFORCING STEEL BENDING DIAGRAM

SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAMETER

'

1'- 7"

c3/8"

-.-------

,-----~,

; ~ 1

10 3/8"

~~~~~r ~

#4

ooTl
~I
I

1'-9"

-'------ '-------~

2'- 8"

1'- 6"

#4

#4

ANCHOR BOLT TEMPLATE ASSEMBLY


ANCHOR BOLT TEMPLATE- (2) REQUIRED
ANCHOR BOLT 1/2" x 28" FULL THREAD(4) REQUIRED
1/2" HEX NUTS- (4) REQUIRED
PER ANCHOR BOLT
FLAT WASHERS, ASTM F 436(4) REQUIRED PER ANCHOR BOLT

DIMENSIONS ARE OUT TO OUT

ACCESSIBLE PEDESTRIAN
PUSHBUTTON WITH
CURB BASE
STANDARD PLAN J-20.11-01

ELECTRICAL CONDUIT- SEE


CONTRACT PLANS FOR DIAMETER

SHEET 2 OF 2 SHEETS

2 1/2" CLR.
(TYP.)

APPROVED FOR PUBLICATION

2'- 0"

Pasco Bakotich Ill

SQUARE
ELEVATION

FOUNDATION DETAIL

PERSPECTIVE VIEW

.....

STATE DESIGN ENGINEER

6110113
DATE

. . . Washington State Department of Transportation

TYPE 1 SIGNAL STANDARD DETAILS

NOTES
3" PEDESTRIAN
PUSHBUTTON POST

BRACKET ADAPTER (TYP.)


---.. ~

GROUNDING CONNECTION
-SEE DETAIL

'

1. See Standard Specification 9-06.16 for Breakaway Base Connection details. Dimensions for thE
parts used to assemble the base connections are intentionally not shown. Base connections are
patented manufactured products that are in compliance with NCHRP 350 crash test criteria.
The Breakaway Base Connection details are only shown on this plan to illustrate how parts are
assembled.

\I

2. See Standard Plan J-20.26 for Accessible Pedestrian Pushbutton details.


0

ANCHOR
COUPLING
(TYP.)

3. Secure conductor in adjacent Junction Box per detail, Standard Plan J-28.70.

EQUIPMENT GROUNDING
CONDUCTOR

4. When additional crossing time is needed, install plaque (R10-32P) "PUSH BUTTON FOR 2
SECONDS FOR EXTRA CROSSING TIME" above the Accessible Pedestrian Signal assembly.
Add 14" to post to accommodate plaque and leave a 2" space between signs.

5. Junction Box serving the Standard shall preferably be located 5'- 0" (10'- 0" Max.) from the
Standard.

FIELD DRILL AND TAP FOR


1/4-20 THREAD BOLT (TYP.)

ANCHOR FERRULE
(TYP.)

_::_~J/

PIPE CAP

----

SHIM (TYP.)- NO MORE THAN


(2) PER COUPLING

TOP OF POST

STAINLESS STEEL
FLAT WASHER (TYP.)

""'w
b
z

1/4" x 1-1/4" LONG


STAINLESS STEEL
THREADED STUD

= w
ow
en

POST WALL

l'nz

EXPLODED VIEW

=
= ""'
:c
.....
= en
II

5/8" DIAMETER
HOLE

BREAKAWAY BASE CONNECTOR

EQUIPMENT GROUNDING
CONDUCTOR AND FULL CIRCLE
CRIMP-ON CONNECTOR - CRIMPED
WITH A MANUFACTURER'S
RECOMMENDED CRIMPER

::J

(SEE NOTE 1)

....1

a.

PEDESTRIAN PUSHBUTTON POST 3" STEEL PIPE (SCHEDULE 40)


3" PEDESTRIAN
PUSHBUTTON POST

GROUNDING CONNECTION
DETAIL

POST DETAIL

BRACKET ADAPTER (TYP.)


BRACKET (TYP.)

TOP OF
FOUNDATION

Co

ANCHOR COUPLING (TYP.)


SHIM (TYP.)

TOP OF PAVED
SURFACE

WELD STUD TO POLE WALL TO MAXIMUM EXTENT


POSSIBLE - 1/2" MINIMUM WELD

CONFIGURATIONS VARY AMONG DIFFERENT MANUFACTURERS


(SHOWN EXPLODED FOR CLARITY)

'

3" PEDESTRIAN
PUSHBUTTON POST

COUPLING BOLT (TYP.)

(3) 1/4" STAINLESS


STEEL HEX NUTS

EQUIPMENT GROUNDING
CONDUCTOR
EDGE OF PAVED
SHOULDER

BRACKET ADAPTER
BRACKET (TYP.)

Co

3/8" PREMOLDED
JOINT FILLER

;....'

EDGE LINE

COUPLING BOLT
(TYP.)

COMMERCIAL
CONCRETE

;....

c-.'

"
~

TOP OF

ANCHOR FERRULE
(TYP.)

SHIM (TYP.)

FOUNDATION
ANCHOR COUPLING
(TYP.)

ANCHOR
FERRULE (TYP.)

CONDUIT COUPLING - INSTALL


FLUSH WITH TOP OF FOUNDATION
(DO NOT GLUE PVC STUB-OUT)

1" DIAMETER ELECTRICAL


CONDUIT

6"

1'- 6"

1" DIAM. ELECTRICAL


CONDUIT

SQUARE

FOUNDATION DETAIL

SECTION

~-----.___

~
PERSPECTIVE VIEW

ACCESSIBLE BREAKAWAY
PEDESTRIAN PUSHBUTTON
(PPB) POST
STANDARD PLAN J-20.15-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


6110113
-----------------------STATE DESIGN ENGINEER
DATE

.....

. . . Washington State Department of Transportation

NOTES
PEDESTRIAN SIGNAL HEAD
WITH TYPE D MOUNT

1. See Standard Plan J-21.1 0 for Signal Standard Foundation with Fixed Base
and Slip Base details.
2.

3. All poles shall be hot dip galvanized per AASHTO M 111.

TOP OF
POLE

TOP OF
POLE

Steel shaft shall be tapered either round or dodecagon (12-sided), 11 gage,


4 1/2" O.D. at slipfitter weld. Taper shall be 0.14 inches per foot.

4. Welding of structures shall be in accordance with the latest edition of the


AWS 01.1 Structural Welding Code - Steel. All butt welds shall be ground
flush with base metal.

1/4" WEEP HOLE


1/4" WEEP HOLE

1/4"
WEEP
HOLE

5.

See Standard Plan J-20.26 for Accessible Pedestrian Pushbutton details.

6.

See Standard Plan J-20.20 for Accessible Pedestrian Signal Standard


Electrical details.

7.

Hand holes shall include a removable, rain-tight cover and gasket, fastened
with two stainless steel screws (ASTM 593).

8.

Grounding Conductor shall be non-insulated #4 AWG stranded copper,


provide 3' - 0' min. slack. Clamp to vertical steel reinforcing bar with
connector suitable for use embedded in concrete.

OFFSET SLIPFITTER

'I_ _ _ _ Lr

BELOW MATCHLINE- SEE DETAILS


ON PEDESTRIAN SIGNAL HEAD
_wiTH TYPE c MOUNT

0
'

MATCHLINE

'

ABOVE MATCHLINE- USE DETAILS


FOR PEDESTRIAN SIGNAL HEAD
WITH TYPE C MOUNT

TYPE C MOUNT PLACEMENT

1" DIAMETER
HOLE (TYP.)

STAINLESS
STEEL NUT

TAPERED STEEL
SHAFT

POLE WALL

TAPERED STEEL SHAFT


-SEE NOTE2

'

STAINLESS STEEL
WASHERS (TYP.)
1/4" DIAMETER x 1" LONG
STAINLESS STEEL STUD

ACCESSIBLE
PEDESTRIAN
PUSHBUTTON
-SEE NOTE6

9" DIAMETER
BOLT CIRCLE

STAINLESS
STEEL NUT

1/2" STEEL PLATE

FULL CIRCLE CRIMP-ON


CONNECTOR (TYP.)

BASE PLATE DETAIL


INSTALL ROSETTE IF
KNOCKOUT IS OPEN

EQUIPMENT GROUNDING
CONDUCTOR

SUPPLEMENTAL GROUNDING
CONDUCTOR

GROUNDING CONNECTION
DETAIL
GROUNDING CONNECTION
-SEE DETAIL

HAND HOLE
- SEE NOTE 7

1/4" WEEP
HOLE

CONFIGURATIONS VARY AMONG DIFFERENT MANUFACTURERS


(SHOWN EXPLODED FOR CLARITY)

TOP OF
FOUNDATION

TOP OF SIDEWALK

LOCK NIPPLE

OFFSET SLIPFITTER OFFSET TO FRONT


OF POLE

~15
1/4" PREMOLDED
JOINT FILLER

PEDESTRIAN SIGNAL
STANDARD (TYPE PS)
DETAILS
STANDARD PLAN J-20.16-01

GROUNDING
CONDUCTOR
- SEE NOTE 8

CONCRETE FOUNDATION
-SEE NOTE 1

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

TYPED MOUNT

VIEW

TYPE D MOUNTING DETAIL

PEDESTRIAN SIGNAL STANDARD

Pasco Bakotich Ill

(FIXED BASE SHOWN)

~SPECTIVE VIEW

.....

STATE DESIGN ENGINEER

7112112
DATE

. . . Washington State Department of Transportation

NOTES
1. See Standard Plan J-21.1 0 for Signal Standard Foundation with Fixed Base
and Slip Base details.
2. See Standard Specification 9-29.3 for Cable Conductor requirements.
3. Install heat shrink caps on all spare conductors not terminated on a terminal strip.
4. Supplemental grounding conductor shall be non-insulated #4 AWG stranded copper
and shall be clamped to vertical rebar with a connector suitable for use embedded
in concrete: provide 3' - 0" min. slack. Attach to pole grounding stud with a full
circle crimp-on connector (crimped with manufacturer's recommended crimper).
5. Equipment grounding conductor shall attach to grounding stud with a full circle
crimp-on connector (crimped with a manufacurer's recommended crimper).
1/4" WEEP HOLE
SEE NOTE3
SLIPFITTER- OFFSET TOP MOUNT,
PLACE OFFSET TO FRONT OF POLE,
DRILL TO SEAT SET SCREWS
FOR SIGNAL HEAD MOUNTING
DETAILS; SEE STANDARD
PLAN J-20.16

1/4" WEEP HOLE

5C PEDESTRIAN HEAD TERMINATIONS

PEDESTRIAN SIGNAL WIRING DETAIL

BRONZE COLLAR AND


TERMINAL COMPARTMENT

(TYPE D MOUNTING SHOWN)

IMSA 20-1 3C #14 CABLE

IMSA 20-1 7C #14 CABLE


- FROM CONTROLLER
(SEE NOTE 3)
IMSA 20-1 7C OR 5C #14 CABLETO SIGNAL DISPLAY (SEE CONTRACT
PLANS FOR WIRE SIZE AND QUANTITIES)

ACCESSIBLE PEDESTRIAN
PUSHBUTTON DETAILSSEE STANDARD PLAN J-20.26

INSULINER SLEEVE

ACCESSIBLE PEDESTRIAN PUSHBUTTON


WIRING DETAIL

STAINLESS STEEL
WASHERS (TYP.)

1/4" DIAMETER x 1" LONG


STAINLESS STEEL STUD

POLE WALL

USE

7*1

DON'T WALK DISPLAY

7*2

WALK DISPLAY

7*3

NEUTRAL CONDUCTOR

7*6

SPARE CONDUCTOR

1*7

SPARE CONDUCTOR

7C PEDESTRIAN HEAD TERMINATIONS

(TYPE C MOUNTING SHOWN)

IMSA 20-1 7C OR 5C #14


CABLE- TO SIGNAL DISPLAY
(SEE CONTRACT PLANS FOR
WIRE SIZE AND QUANTITIES)

COLOR
CODE

* ASSOCIATED PHASE NUMBER

2C(SH)CONDUCTOR
- FROM CONTROLLER

DOUBLE PEDESTRIAN SIGNAL


WIRING DETAIL

TERMINAL
NUMBER

2C (SH) CONDUCTOR - TO PUSHBUTTON


(SEE CONTRACT PLANS FOR QUANTITIES)

TERMINAL
NUMBER

COLOR
CODE

USE

7*1

DON'T WALK DISPLAY

7*2

WALK DISPLAY

7*3

NEUTRAL CONDUCTOR

7*6

SPARE CONDUCTOR

7*1

DON'T WALK DISPLAY

7*2

BL

WALK DISPLAY

7*3

WB

NEUTRAL CONDUCTOR

ASSOCIATED PHASE NUMBER

GROUNDING
CONNECTION
EQUIPMENT GROUNDING
CONDUCTOR- SEE NOTE 5
LEVELING NUT (TYP.)
3/8" DRAIN TUBE

STAINLESS
STEEL NUT

STEEL REINFORCING
BAR (TYP.)
STAINLESS
STEEL NUT

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 4
EQUIPMENT GROUNDING
CONDUCTOR - SEE NOTE 5

FULL CIRCLE CRIMP-ON


CONNECTOR (TYP.)

GROUNDING CONNECTION
DETAIL
CONFIGURATIONS VARY AMONG DIFFERENT MANUFACTURERS
(SHOWN EXPLODED FOR CLARITY)

PEDESTRIAN SIGNAL
STANDARD (TYPE PS)
ELECTRICAL DETAIL
STANDARD PLAN J-20.20-02
SHEET 1 OF 1 SHEET

CONDUIT COUPLING- INSTALL


FLUSH WITH TOP OF FOUNDATION
(DO NOT GLUE PVC STU BOUT)

SUPPLEMENTAL GROUNDING
CONDUCTOR- SEE NOTE 4-~

FOUNDATION WIRING DETAIL

ELECTRICAL CONDUIT- SEE


CONTRACT PLAN FOR DIAMETER

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

[i]

ACCESSIBLE
PEDESTRIAN
PUSHBUTTON
(APS) ASSEMBLY
~:::2::::::::::::::j

~
START CROSSING
Wab:hFor
Vehicles

~--~

OONISTART
-~- IHih Crossing
~/1\~
II'Siartad
TIME REMAINNG
lb Rnlsh C101181ng

ro

/.

[l]

Vahlclaa
,,_/ OON'TSTART
-'~~- RnBhen.smg
~/I\~
II'Siartad
TIME REMAINNG
To Rnlah Crossing

STEADY

DON'T CROSS

ATTACH SIGN TO ADAPTER1/4-20 x 3/8" STAINLESS


STEEL SCREWS (TYP.)

~--~

OONISTART
Rnlsh Crossing
~/1\~
II'Siartad
TIME REMAINNG
lb Rnlah C101181ng

DON'T CROSS
@

@ '------

9"

R10-3e (RIGHT)

ATTACH ADAPTER TO PUSHBUTTON STATION- 1/4" DIAM.


COUNTERSUNK HOLE, 3/8" LONG
FLAT HEAD SCREWS (TYP.)

PUSH BUTTON
TO CROSS

TO CROSS

':I

~
START CROSSING
Wab:h For
Vehicles

-~-

DONI CROSS

PUSH BUTTON

TO CROSS

1\::

[l]

STEADY

STUO\'

PUSH BUTTON ~

INSULINER
SLEEVE

/.
ST::ING

9"

R10-3e (LEFT)

R10-3e (MOD.)

PEDESTRIAN PUSHBUTTON
INSTRUCTIONAL SIGN

PEDESTRIAN PUSHBUTTON
FRAME ADAPTER

WIRE ROUTING
PERSPECTIVE VIEW

ACCESSIBLE PEDESTRIAN
PUSHBUTTON (PPB)
DETAILS
STANDARD PLAN J-20.26-01

KEY

~
@

ffi

FACEPLATE
1/4-20 x 3/8" LONG STAINLESS STEEL SCREW
1/4-20 STAINLESS STEEL SCREWS
PUSHBUTTON FRAME ADAPTER
1/4-20 STAINLESS STEEL BOLT WI WASHER
AND LOCK WASHER
PUSHBUTTON STATION
DRILL AND TAP SHAFT FOR 1/4" DIAM. BOLT
DRILL AND TAP SHAFT FOR 5/8" WIRE GUIDE HOLE -ADD INSULINER

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ACCESSIBLE PEDESTRIAN SIGNAL (ASP) ASSEMBLY


METAL POLE INSTALLATION
PPB-M

Pasco Bakotich Ill


----~=---------

.....

ISOMETRIC VIEW
(METAL POLE SHOWN)

STATE DESIGN ENGINEER

7112112
DATE

. . . Washington State Department of Transportation

WOOD POST

=====~====~

COUNTERBORE - DIAMETER
TO FIT CONDULET

4 POST

I
I

~~======::~-~~~~~=~-

9
13

11

WOOD POLE INSTALLATION


ALTERNATIVE 1
PPB-W
(ACCESSIBLE PEDESTRIAN PUSHBUTTON - TEMPORARY TIMBER STRAIN POLE)

WOOD POLE INSTALLATION


ALTERNATIVE 3
PPB-W

INSTALL FITTING WITH NYLON WASHER ON OUTSIDE OF HOUSING


- SEAL WITH SILICONE AFTER UNIT IS FULLY ASSEMBLED

(ACCESSIBLE PEDESTRIAN PUSHBUTTON -TEMPORARY TIMBER POLE)

10

... c::>-
KEY
1

FACE PLATE
1/4-20 x 3/8" LONG STAINLESS STEEL SCREW
1/4-20 STAINLESS STEEL SCREWS
PUSHBUTTON FRAME ADAPTER
LAG BOLT WITH WASHER
PUSHBUTTON STATION
CONDUIT DIAMETER+ 1/8" HOLE THRU POLE
CONDULET
LIQUID-TITE FLEX CONDUIT
ONE PIECE TWO HOLE CLAMP
LAG BOLT
INSULINER SLEEVE

PRE-DRILL (3) 1/4" WEEP HOLES IN


BOTTOM RADIUS OF CONDUIT
DRIP LOOP. REAM HOLES WITH
DRILL BIT TO ELIMINATE BURRS

ACCESSIBLE PEDESTRIAN SIGNAL (ASP) ASSEMBLY


WOOD POLE INSTALLATION
ALTERNATIVE 2
PPB-W
(ACCESSIBLE PEDESTRIAN PUSHBUTTON -TEMPORARY TIMBER STRAIN POLE)

ACCESSIBLE PEDESTRIAN
PUSHBUTTON (PPB)
DETAILS
STANDARD PLAN J-20.26-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


------~=--------------

.....

STATE DESIGN ENGINEER

7112112
DATE

. . . Washington State Department of Transportation

TEMPORARY TIMBER POLE

REINFORCING STEEL BENDING DIAGRAM

NOTES
1. Steel Shaft shall be tapered either round or dodecagon (12-sided), 11-gauge, 4 1/2" O.D. at slipfitter.
Taper shall be 0.14 inches per foot.

9"

SEE STD. SPEC. 9-07.1(2) FOR BENDING DIAM.

I.

.I

1'- 7"

~ I'f..

....

CD

135"
HOOK
(TYP.)

TAPERED
STEEL SHAFT SEE NOTE 1

#4

2. Hand Holes shall include a removable, rain-tight cover and gasket, fastened with two stainless steel screws
(ASTM F 593).
3. Clamping Bolts shall be tightened to 50 ft-lbs max. torque. After state inspection, burr threads to prevent
nut rotation. DO NOT OVERTIGHTEN.

2 1/2" CLR.
(TYP.)

4. The final height of the Anchor Bolts must be below the top of the Slip Plate Assembly to ensure proper
function of the Slip Base.

9" DIAM. BOLT


CIRCLE
ELECTRICAL
CONDUIT

1/2" STEEL PLATE

5. All Poles shall be hot dip galvanized per AASHTO M111.

WITH HOLE=
POLE BASE + 1/6"

BASE PLATE DETAIL

6. Supplemental Grounding Conductor shall be non-insulated #4 AWG stranded copper, provide 3'- 0" min.
slack. Clamp to vertical steel reinforcing bar with connector suitable for use embedded in concrete.

CENTER ANCHOR BOLT


ASSEMBLY IN FOUNDATION

DIMENSIONS ARE OUT TO OUT

SECTION

7. Junction Box serving the Standard shall preferably be located 5'- 0" (10'- 0" Max.) from the Standard.
8.

@#4
..J
..J

c
c

r.l\ # 4 (TYP.)
\:V (8) REQ'D.

SLIPFITTER

0::

b~

u.

BASE PLATE ASSEMBLY -1/2" DIAM.


STEEL HEX NUT, WITH 1 1/2" FLAT
WASHER, 2 EACH REQ'D PER
ANCHOR BOLT- MINIMUM OF
2 THREADS ABOVE TOP OF
NUT OR 5/8" MAXIMUM (TYP.)

SUPPLEMENTAL GROUNDING CONDUCTOR SEE NOTE 6

CENTER ANCHOR BOLT


ASSEMBLY IN FOUNDATION

1/8

1/2" STEEL BASE PLATE -

SECTION
SEE DETAILS ABOVE MATCHLINE ON
SQUARE CONCRETE

4" X 6" HAND HOLE SEE NOTE 2

GROUNDING STUD WITH NUT SEE STANDARD PLAN J-20.20 FOR


GROUND CONNECTION DETAILS

<C
c-..Ci

ELECTRICAL
CONDUIT

TAPERED STEEL SHAFT SEE NOTE 1

TOP OF
POLE

::::i

Provide Cable Tie at wiring entering the Junction Box (for Slip Base installations only) - See Detail A,
Standard Plan J-28.70 .

FOUNDAT~~ ~--

TAPERED STEEL SHAFT


- SEE NOTE 1

SEE DETAIL
0::

~
z
~
en

MATCHLINE

GROUNDING STUD WITH NUT

3/8" PRE-

MOULD~~l

JOINT FILLE/

UNPAVED
SURFACE

u.
0

HAND HOLE SEE NOTE 2

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 6

TOP OF FOUNDATION

GROUT PAD - INSTALL AFTER


PLUMBING STANDARD

: :

1-

......--- +-+----++-

::c
(!)

MATCHLINE

3/4" CHAMFER (TYP.)

iii

::c

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 6

--.,-,-..~ ---++--- - - 1
L_~

HAND HOLE SEE NOTE 2

.)

3/4" x 2- 6" ANCHOR BOLT (TYP.) (4) REQUIRED (SEE NOTE 4)


CONDUIT COUPLING - INSTALL FLUSH
WITH TOP OF FOUNDATION

3/4" CHAMFER (TYP.)

UNPAVED SURFACE

l
@#4

....

(TYP.)
(5) REQ'D.

ELECTRICAL CONDUIT - SEE


CONTRACT PLAN FOR DIAM.
ANCHOR BOLT ASSEMBLY (TYP.)

'

1" DIAM.
HOLE (TYP.)

1/4" STEEL
PLATE

ELECTRICAL CONDUIT- SEE


CONTRACT PLAN FOR DIAM.

ANCHOR BOLTS (4) REQ'D. FOR ASSEMBLY

ANCHOR BOLT ASSEMBLY (TYP.)

ANCHOR BOLT TEMPLATE,


(2) REQ'D PER ASSEMBLY

ANCHOR BOLTS
(4) REQ'D. FOR ASSEMBLY

3/4" HEX NUTS, STEEL,


(4) REQ'D. PER ANCHOR BOLT

ANCHOR BOLT TEMPLATE,


(2) REQ'D. PER ASSEMBLY

FLAT WASHERS,
(4) REQ'D. PER ANCHOR BOLT

2 1/2" CLR.

3/4" HEX NUTS, STEEL,


(4) REQ'D. PER ANCHOR BOLT

2'- 0"
ROUND
ELEVATION

ROUND CONCRETE FOUNDATION DETAIL

9" BOLT CIRCLE

2 1/2" CLR.

ANCHOR BOLT TEMPLATE

SHEET 1 OF 2 SHEETS

2'- 0"
SQUARE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

FLAT WASHERS,
(4) REQ'D. PER ANCHOR BOLT
ELEVATION

FIXED BASE

TYPE PS, TYPE 1 RM


& FB SIGNAL STANDARD
FOUNDATION DETAILS
STANDARD PLAN -J-21.10-03

SQUARE CONCRETE FOUNDATION DETAIL

......

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

7/8" DIAM. HOLE (TYP.)

1" DIAM. HOLE (TYP.)

~./

TAPERED STEEL
SHAFT WALL

1'- 3" DIAM.


BOLT

CIRC~

HOLE DIAM.
POLE BASE+ 1/16"

~a.
....= ~

"" \ .

ANCHOR PLATE

3/8

0
N
6" DIAM. HOLE

7" DIAM. HOLE

6" DIAM.
HOLE

6"

5/8" R.
(TYP.)

9"

ANCHOR PLATEASTM A572 GR. 50


ORASTM A588

.. I ..

8 1/2"

KEEPER PLATE

SECTION

BASE PLATEASTM A36

@#4 (TYP.)
(8) REQ'D.

8 1/2"

BASE PLATE DETAIL

LlJ

c
c

28 GAUGE KEEPER PLATE

CD "I

HARDENED ROUND WASHER


(TYP.)- SIZE TO MATCH
CLAMPING BOLT

@#4
(TYP.)
8 REQ'D.

TOP OF CONCRETE
FOUNDATION

~
c

1/2" THICK X 2" WIDE X


2 3/4" LONG STEEL BAR

2 1/2" CLR.
(TYP.)

@#4

SECTION
SEE DETAILS ABOVE MATCHLINE FIXED BASE SQUARE CONCRETE ~
FOUNDATION, SHEET 1

---- -

....1...-J,- ---1--1~--r...;:.:::;:..-

LEVELING NUT (TYP.) - _ _ _..:.


3/4" HEAVY HEX NUT
AND HARDENED WASHER

MATCH LINE
SEE DETAILS ABOVE MATCHLINE FIXED BASE SQUARE CONCRETE
FOUNDATION, SHEET 1

HAND HOLE SEE NOTE 2

3/4" CHAMFER (TYP.)


UNPAVED SURFACE

lo

I~ I

--

TOP OF BASE PLATE

3/4" x 2' - 6" ANCHOR BOLT


(4) REQUIRED (SEE

SECTION
MATCHLINE

--

GROUNDING STUD WITH NUT

i~

t: ""'--- SEE
ELECTRICAL CONDUITCONTRACT PLANS FOR DIAM.

6" DIAM. HOLLOW


INCENTER OF
GROUT PAD

STEEL REINFORCING
BARS

SQUARE FOUNDATION SHOWN

DETAIL

l
@#4
(TYP.)
(5) REQ'D.

CONDUIT COUPLING - INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

CLAMP - SEE NOTE 6

HAND HOLE SEE NOTE 2

ELECTRICAL CONDUIT SEE CONTRACT PLANS


FOR DIAM.

3/4" CHAMFER (TYP.)

@#4
(TYP.)

1 3/16" DIAM.
(TYP.)
TACK WELD- AT
ALL OVERLAPPING
LOCATIONS (TYP.)

ELECTRICAL CONDUITSEE CONTRACT PLANS FOR DIAM.

ANCHOR BOLT ASSEMBLY


(TYP.)

ANCHOR BOLT ASSEMBL


(TYP.)
ANCHOR BOLTS (4) REQ'D. FOR ASSEMBLY

ANCHOR BOLTS (4) REQ'D PER ASSEMBLY (TYP.)


STRAP TEMPLATE(3) 1/4" STEEL BARS;
(2) REQ'D. PER ASSEMBLY

FLAT WASHERS(4) REQ'D. PER ANCHOR BOLT

-.1....1...+ - - ______.

PLATE WASHER DETAIL

GROUNDING STUD WITH NUT

3/4" HEX NUTS, STEEL (4) REQ'D. PER ANCHOR BOLT

PAVED SURFACE
1 3/8" SLIP PLATE

UNPAVED
SURFACE

ELECTRICAL CONDUIT

1/2" BASE PLATE

1 1/4" ANCHOR PLATE

::::i
LlJ
LL.

PLATE WASHER (TYP.)

2'- 0"
sC TOWARD ROADWAY

CENTER ANCHOR BOLT


ASSEMBLY IN FOUNDATION

a::

HEAVY HEX NUT (TYP.) -SIZE


TO MATCH CLAMPING BOLT

3/4" CLAMPING BOLT (TYP.) - SEE NOTE 3


3/4" HEAVY HEX NUT AND
HARDENED WASHER

...I
...I

HEAVY HEX CLAMPING BOLT


(TYP.) - 3/4" DIAM. TORQUE
CLAMPING BOLTS - SEE NOTE 3

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 6

FOR DIMENSIONS NOT SHOWN,


SEE SLIP AND ANCHOR PLATES DETAIL

7/8" DIAM.
HOLE W/ SMOOTH
CHAMFERED EDGES

CENTER ANCHOR BOLT


ASSEMBLY IN FOUNDATION

SECTION

GROUNDING STUD WITH NUTSEE STANDARD PLAN J-20.20 FOR


GROUNDING CONNECTION DETAILS

KEEPER PLATE DETAIL

SLIP AND ANCHOR PLATES DETAIL


sC TOWARD ROADWAY

(28 GAGE SHEET METAL)


PLACE BETWEEN POLE BASE PLATE AND
SLIP PLATE ON TOP OF MIDDLE WASHERSSEE STANDARD PLAN J-28.42

FOR DIMENSIONS NOT SHOWN,


SEE BASE PLATE DETAIL

TAPERED STEEL SHAFT SEE NOTE 1

BASE
PLATE

STRAP TEMPLATE(3) 1/4" STEEL BARS;


(2) REQ'D. PER ASSEMBLY

2 1/2" CLR.

3/4" HEX NUTS, STEEL (4) REQ'D. PER ANCHOR BOLT

2'- 0"
ROUND

ELEVATION

ROUND CONCRETE FOUNDATION DETAIL

1/4" STEEL BAR (TYP.) 2" WIDE X 1'- 3" LONG

STRAP TEMPLATE DETAIL

SHEET 2 OF 2 SHEETS

2'- 0"
SQUARE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

FLAT WASHERS(4) REQ'D. PER ANCHOR BOLT


ELEVATION

SLIP BASE

TYPE PS, TYPE 1 RM


& FB SIGNAL STANDARD
FOUNDATION DETAILS
STANDARD PLAN -J-21.10-03

SQUARE CONCRETE FOUNDATION DETAIL

......

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

NOTES

HOUSING FIXTURE
-THREE 12" LENSES

....1
....1

1. See Standard Plan J-21.1 0 for Signal Standard Foundation with


Fixed Base and Slip Base details.

0
0

::J

z
c:::
w

11..

2.

PLACE BEAD OF SILICONE


ON TOP OF SEARRATED AREA
END CAP

3. All poles shall be hot dip galvanized per AASHTO M111.

NEOPRENE GASKET

HOUSING FIXTURE
- THREE 12" LENSES

STEEL WASHER

4. Welding of structures shall be in accordance with the latest edition


of the AWS 01.1 Structural Welding Code - Steel. All butt welds
shall be ground flush with base metal.

TOP OF POLE

5.

See Standard Plan J-21.20 for Electrical details.

6.

Pedestrian signal displays mounted on the side of an octagonal (8 sided)


traffic signal pole with a pole attachment angle other than 0, 45, 90,
135, 180, 225, 270, or 315 shall utilize:

1 1/2" DIAM.
CONDUIT LOCKNUT
RUBBER
SEAL (TYP.)

MOUNTING ASSEMBLY (TYP.)

SLIPFITTER

LOCK NIPPLE
- 1 1/2" DIAM.

Type A mounting when two pedestrian heads are installed on


the same signal pole.

Type B mounting when only one pedestrian signal head is


mounted on a signal pole.

7. Junction Box serving the Standard shall preferably be located 5'- 0"
(10'- 0" Max.) from the Standard.

1/4" WEEP HOLE

6
~

Steel shaft shall be tapered either round or dodecagon (12 sided),


11 gage, 4 1/2" O.D. at slipfitter. Taper shall be 0.14 inches per foot.

SLIPFITIER- OFFSET TOP


MOUNT, SET OFFSET TO
BACK OF POLE.
b

TAPERED STEEL SHAFT


-SEE NOTE 2

b
~

ACCESSIBLE PEDESTRIAN PUSHBUTTON


18" 1ir" =-=-=-="",l'v WITH DUEL ASSEMBLY MOUNTING
==~::
ADAPTER (TYP.)
MAX . 11===
Ill

TAPERED STEEL SHAFT

111

II

"''=--=-

'"

II\:_.,_

''"

(o

'
SIDEWALK EDGE

CONCRETE FOUNDATION
-SEE NOTE 1

TOP OF
FOUNDATION

1"- 2"

PAVED SURFACE

TYPE 1 SIGNAL
STANDARD DETAILS

UNPAVED
SURFACE
FLUSH WITH TOP
OF SIDEWALK

STANDARD PLAN .J-21.15-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

CONCRETE FOUNDATION
-SEE NOTE 1

TYPE 1 SIGNAL STANDARD


FIXED BASE SHOWN

STATE DESIGN ENGINEER

ISOMETRIC VIEW

......

6110113
DATE
0

~ Washington State Department of Transportation

END CAP

0Cb

PLACE BEAD OF SILICONE ON TOP


OF SERRATED AREA

FLASHING BEACON
8" POLYCARBONATEFULL CIRCLE VISOR
(SEE NOTE 5)

I. 1'- 3"

FLASHING BEACON
TOP OF
POLE

NOTES

1'- 3" .j
TOP OF
POLE

FLASHING BEACON (TYP.)

~~---_L----.--

1/4" WEEP
HOLE

3.

MOUNTING BRACKET
AND STEEL STRAP (TYP.)
-SEE STANDARD PLAN G-24.10

MOUNTING BRACKET
AND STEEL STRAP (TYP.)
-SEE STANDARD PLAN G-24.10

SLIPFITTER - OFFSET TOP


MOUNT. PLACE OFFSET
TO BACK OF POLE

2. All poles shall be hot dip galvanized per


AASHTO M111.

CD

LOCKNIPPLE

SIGN PANEL

SIGN PANEL
0

SIGN BRACE - SEE


STANDARD PLAN G-50.10

1. See Standard Plan J-21.1 0 for Signal


Standard Foundation details.

SIGN BRACE - SEE


STANDARD PLAN G-50.10

Welding of structures shall be in accordance with the latest edition of the AWS
01.1 Structural Welding Code - Steel. All
butt welds shall be ground flush with base
metal.

4. Visor shall be 8" Polycarbonate, fully enclosed circle at bottom to reduce glare on
sign. Display shall be of appropriate color
needed.
5. See Standard Plan J-21.17 for Electrical
details.
6. Junction Box serving the Standard shall
preferably be located 5'- 0" (10'- 0" Max.)
from the Standard.

TAPERED STEEL
SHAFT

DETAIL

SINGLE FLASHING BEACON DETAIL

BOTTOM
OF SIGN

BOTTOM OF SIGN

USE DETAILS BELOW MATCHLINE

ON

::~2~:J~ ~~!;~ l____ ~

USE DETAILS BELOW MATCHLINE


FOR RAMP METER WITH SINGLE ~
FLASHING BEACON

-- ----------

MATCHLINE

1 1/2" DIAM.

SERRATED OR FLANGED ELBOW

SINGLE FLASHING BEACON


REAMED TEE WITH
SETSCREW
CONDUIT LOCKNUT1 1/2" DIAM.

SERRATED RING NO PINS

HEX LOCKNUTALLEN HEAD STAINLESS


STEEL SET SCREWS, (2 REQ'D.)
PIN RECEPTACLES

NIPPLE - 1 1/2" DIAM.

TAPERED STEEL SHAFT


-SEE NOTE 2

HEX LOCKNUT (TYP.)


NIPPLE1 1/2" DIAM.

SERRATED RING WITH PINS


PLACE BEAD OF SILICONE ON
TOP OF SERRATED AREA

SERRATED RING- NO PINS

SLIPFITTER - OFFSET TOP MOUNT


PLACE OFFSET TO BACK OF POLE
TOP OF

FLASHING WARNING BEACON

[ _ FOUNDArN

....

NEOPRENE GASKET
STEEL WASHER
TAPERED STEEL
SHAFT

HEX LOCKNUT- 1 1/2" DIAM.

FLASHING BEACON
TYPE 1 SIGNAL
STANDARD DETAILS
STANDARD PLAN J-21.16-01

CONCRETE FOUNDATION
-SEE NOTE 1

CONDUIT LOCKNUT- 1 1/2" DIAM.


1/4" WEEP
HOLE

ORNAMENTAL CAP WITH 2-WAY FLASHER,


NEOPRENE GASKET AND LOCKNUT

DETAIL

..

.
~

..

SHEET 1 OF 1 SHEET

ALTERNATING FLASHING BEACON DETAIL

ALTERNATING FLASHING BEACON

(SHOWN WITHOUT HINGE DOOR FOR CLARITY)

FLASHING BEACON TYPE 1


SLIP BASE SHOWN

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

NOTES

SEE STANDARD PLAN J-21.16 FOR


MOUNTING HARDWARE DETAILS
2C (SH) B&W CABLE

..J
..J

1. See Standard Specification 9-29.3 for Cable Conductor requirements.


2. See Standard Plan J-21.16 for Flashing Beacon Type 1 Signal Standard details.

FITTING HARDWARE - SEE


ALTERNATING FLASHING BEACON
DETAIL ON STANDARD PLAN J-21.16

CLAMP CONDUCTORS
TO PREVENT SLIPPING
(TYP.)

c
c

8" FLASHING WARNING


BEACON HOUSING (TYP.)

::::i

0:::

w
u.

TERMINAL
BLOCK (TYP.)

TERMINAL
BLOCK (TYP.)

2C (SH)

3. Supplemental Grounding Conductor shall be non-insulated #4 AWG stranded copper,


provide 3' - 0" min. slack. Clamp to vertical steel reinforcing bar with listed connector
suitable for use embedded in concrete.
4. See Standard Plan J-21.10 for foundation requirements.
TOP OF
POLE

5. Provide Cable Tie at wiring entering the Junction Box


(for Slip Base installations only) - See Detail A,
Standard Plan J-28.70.

POLE

1/4" WEEP HOLE

ORNAMENT CAP WITH 2-WAY FLASHER


FLASHER 1

ORNAMENT CAP
- WITH FLASHER

2C (SH) B&W CABLE


- FROM FOUNDATION
WIRING

DETAIL

8" FLASHING WARNING


BEACON HOUSING

1/4" WEEP HOLE

ORNAMENT CAP

TOP OF
POLE

FLASHER2

COLOR
CODE

FLASHING BEACON WIRING


ALTERNATING FLASH
WIRING SHOWN

USE

POWER

NEUTRAL

FLASHER 1

Bu

FLASHER 2

TERMINAL BLOCK

f-.

PERSPECTIVE VIEW

2C (SH) B&W CABLE


- TO FLASHING BEACON

FLASHING BEACON TYPE 1

POLE

SINGLE FLASH BEACON SHOWN


GROUNDING STUD WITH NUT SEE STANDARD PLAN J-20.20 FOR
GROUND CONNECTION DETAILS
INSTALL SIZED REDUCING
WASHER AND CONNECTOR
TO SECURE CONDUCTORS
AT TOP OF POLE

HAND HOLE

INSTALL UNFUSED QUICK DISCONNECT


FOR W CONDUCTOR, AND FUSED FOR
B CONDUCTOR - PULL DOWN TIGHT
TO CONDUIT

EQUIPMENT GROUNDING
CONDUCTOR

1/4" WEEP HOLE

LEVELING NUT (TYP.)

2C (SH) B&W CABLE


- FROM FOUNDATION WIRING

CONDUIT COUPLING - INSTALL


FLUSH WITH TOP OF FOUNDATION
(DO NOT GLUE PVC STUBOUT)

STEEL REINFORCING
BAR (TYP.)

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 3

POLE

FLASHING BEACON WIRING

1" DIAMETER ELECTRICAL

~CONDUIT

CLAMP CONDUCTOR TO
STEEL REINFORCING WITH
LISTED CONNECTOR
SUITABLE FOR USE
EMBEDDED IN CONCRETE

DETAIL

DETAIL

FLASHING BEACON
TYPE 1 SIGNAL STANDARD
ELECTRICAL DETAILS

I
I
I
I
I
I
I
I

STANDARD PLAN J-21.17-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

FOUNDATION WIRING
PERSPECTIVE VIEW

SINGLE FLASH WIRING SHOWN

FIXED BASE SHOWN

FLASHING BEACON TYPE 1


ALTERNATING FLASH BEACON SHOWN

Pasco Bakotich Ill


6110113
-----------------------STATE DESIGN ENGINEER
DATE

.....

. . . Washington State Department of Transportation

NOTES
....1
....1

0
0

1. See Standard Specification 9-29.3 for Cable Conductor requirements.

z
c:::

2. See Standard Plan J-21.10 for Signal Standard Foundation with Fixed Base and Slip Base details.

::J
w

11..

3. Supplemental Grounding Conductor shall be non-insulated #4 AWG stranded copper, provide


3'- 0" min. slack. Clamp to steel reinforcing bar with connector suitable for use embedded
in concrete.

TERMINAL
NUMBER

MARK

DEFINITION

6*1

RED DISPLAY

6*2

AMBER DISPLAY

6*3

GREEN DISPLAY

6*4

SPARE CONDUCTOR

6*6

NEUTRAL CONDUCTOR

TERMINAL
BLOCK

4.

Heat shrink cap all spare conductors not terminated on a terminal strip.

5. When a Pedestrian Push Button is specified in contract plans, see Standard Plan J-20.20 for details.
6.

Provide Cable Tie at wiring entering the Junction Box (for Slip Base installations only) - See Detail A,
Standard Plan J-28. 70.

ASSOCIATED PHASE NUMBER

0
G
IMSA 20-1 5C #14 CABLE
-CONTINUING TO SIGNAL DISPLAY
(SEE CONTRACT PLAN FOR WIRE
SIZE AND QUANTITIES)

B(SEE~TE4)

TOP OF POLE

POLE

R
GROUNDING STUD WITH NUT - SEE
STANDARD PLAN J-20.20 FOR
GROUND CONNECTION DETAILS

HAND HOLE

INSTALL SIZED REDUCING


WASHER AND CONNECTOR
TO SECURE CONDUCTORS
AT TOP OF POLE

EQUIPMENT GROUNDING
CONDUCTOR
LEVELING NUT (TYP.)

SLIPFITTER - OFFSET TOP MOUNT,


PLACE OFFSET TO BACK OF POLE

STEEL REINFORCING
BAR (TYP.)

....

CONDUIT COUPLING - INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

IMSA 20-1 5C #14 CABLE


-CONTINUED FROM FOUNDATION
CLAMP - SEE NOTE 3

CONCRETE FOUNDATION
-SEE NOTE 1

TYPE 1 SIGNAL STANDARD


ELECTRICAL DETAILS

ELECTRICAL CONDUIT - SEE


CONTRACT PLAN FOR DIAMETER

SIGNAL WIRING DETAIL


FOUNDATION WIRING DETAIL

STANDARD PLAN .J-21.20-01


SIDEWALK EDGE

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

FLUSH WITH TOP


OF SIDEWALK

.....

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

ISOMETRIC VIEW

ENDCAP~
PLACE BEAD OF SILICONE ON
TOP OF SERRATED AREA

NOTES

UPPER TRAFFIC SIGNAL HEAD


-THREE 12" LENSES

NEOPRENE GASKET

1. See Standard Plan J-21.1 0 for Signal Standard Foundation Details.

STEEL WASHER

2. Steel sha~ shall be tapered either round or dodecagon (12 sided), 11 gage, 4 1/2"
O.D. at shpfitter. Taper shall be 0.14 inches per foot.

::::i

3. All poles shall be hot dip galvanized per AASHTO M111.

1 1/2" DIAM. CONDUIT LOCKNUT

....1
....1

Cl
Cl

0::

~
z

4. Welding of structures shall be in accordance with the latest edition of the AWS 01.1
Structural Welding Code - Steel. All butt welds shall be ground flush with base metal.

MOUNTING
ASSEMBLY
(TYP.)

LL.

HOUSING FIXTURE
-THREE 12" LENSES

5. See Standard Plan J-22.16 for Wiring and Electrical details.

Cl

6. Junction Box serving the Standard shall preferably be located 5


from the Standard.

NEOPRENE GASKET
SLIPFITTER - OFFSET TOP
MOUNT, SET OFFSET TO
BACK OF POLE, DRILL TO
SEAT SET SCREWS

1
-

0" Max.)

LOWER TRAFFIC SIGNAL HEAD


- THREE 8" LENSES

[jy-

0" (10

TOP OF POLE

LOCK NIPPLE
- 1 1/2" DIAM.

STEEL WASHER

1/4" WEEP HOLE

b
I

I
I
I

TAPERED STEEL SHAFT

BOTTOM OF LOWER
TRAFFIC SIGNAL HEAD

DETAIL

UPPER TRAFFIC SIGNAL HEAD TOP MOUNT


TYPED

TAPERED STEEL SHAFT


-SEE NOTE 2

SERRATED OR FLANGED
ELBOW (TYP.)
PLACE BEAD OF SILICONE ON
TOP OF SERRATED AREA

L-ijf---

NIPPLE (TYP.)
1112" DIAM.

NEOPRENE GASKET (TYP.)

REAMED ELBOW

3 lj~ WITH SET SCREW


Co

STEEL
WASHER
(TYP.)

CENTER PIPE
- 1 1/2" DIAM.
HOUSING FIXTURE
- THREE 8" LENSES

MOUNTING
ASSEMBLY
(TYP.)

GROUNDING STUD WITH NUT SEE STANDARD PLAN J-20.20 FOR


GROUND CONNECTION DETAILS

BRONZE 12 SECTION TERMINAL


BLOCK COMPARTMENT

HAND
HOLE

FIELD DRILL POLE AND INSERT AN


INSULINER OR SIMILAR DEVICE TO
PROTECT CONDUCTORS

STANDARD PLAN J-22.15-01

1/4" WEEP HOLE


LOCK NIPPLE (TYP.)
- 1 1/2" DIAM.

RAMP METER SIGNAL


STANDARD DETAILS

TOP OF FOUNDATION

CLAMP

DETAIL

LOWER TRAFFIC SIGNAL HEAD SIDE MOUNT


TYPEK

SHEET 1 OF 1 SHEET

CONCRETE FOUNDATION
-SEE NOTE 1

APPROVED FOR PUBLICATION

TAPERED STEEL SHAFT

Pasco Bakotich Ill

RAMP METER SIGNAL STANDARD


SLIP BASE SHOWN

PERSPECTIVE VIEW

......

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

HOUSING FIXTURE
-THREE 12" DISPLAYS

NOTES

HOUSING FIXTURE
-THREE 8" DISPLAYS

1. See Standard Plan J-21.1 0 for Ramp Meter Signal Standard and Foundation Details
2. See Standard Specifications 9-29.17 for additional Mounting Bracket and Fitting
information not shown.
IMSA 20-1 5C #14 CABLE
CONTINUING TO UPPER
TRAFFIC SIGNAL HEAD

...J
...J

LlJ

3. Supplemental Grounding Conductor shall be non-insulated #4 AWG stranded copper,


provide 3' - 0" min. slack. Clamp to steel reinforcing bar with connector suitable for
use embedded in concrete.
4. Top of Leveling Nut height shall be 1" maximum above foundation.

Cl
Cl

TERMINAL BLOCK

::::i

0::

BRONZE 12 SECTION
TERMINAL COMPARTMENT

LlJ
LL.

5. Heat shrink cap all spare conductors not terminated on a terminal strip.
6. Provide Cable Tie at wiring entering the Junction Box (for Slip Base installations only)
- See Detail A, Standard Plan J-28.70.

TERMINAL BLOCK_ SHOWN

CUT AWAY FOR CLARITY

Cl

FIELD DRILL HOLE AND INSERT


AN INSULINER OR SIMILAR DEVICE
TO PROTECT CONDUCTORS

B
INSTALL SIZED REDUCING WASHE
AND CONNECTOR TO SECURE
CONDUCTORS AT TOP OF POLE

DRILL AND TAP BOLT (TYP.)

1/4" WEEP HOLE


IMSA 20-1 5C #14 CABLECONTINUED FROM LOWER
TRAFFIC SIGNAL HEAD

DETAIL

1/4" WEEP HOLE


IMSA 20-1 5C #14 CABLE

SLIPFITTER - OFFSET TOP MOUNT,


PLACE OFFSET TO BACK OF POLE,
DRILL TO SEAT SET SCREWS

1/4" WEEP HOLE


IMSA 20-1 5C #14 CABLE
CONTINUED FROM FOUNDATION
WIRING

DETAIL

UPPER TRAFFIC SIGNAL HEAD WIRING

IMSA 20-1 5C #14 CABLECONTINUING TO TERMINAL


COMPARTMENT

USE

RED DISPLAY

POLE

HAND HOLE

SPARE WIRE (TYP.) - HEAT SHRINK CAPPED,


CABLE TIE TO IMSA 20-1 5C #14 CABLE
(SEE NOTE 5)

AMBER DISPLAY

GREEN DISPLAY

NEUTRAL CONDUCTOR

SPARE CONDUCTOR

LOWER TRAFFIC SIGNAL HEAD WIRING


(SHOWN LARGER FOR CLARITY)

GROUNDING STUD WITH NUT SEE STANDARD PLAN J-20.20 FOR


GROUND CONNECTION DETAILS
COLOR
CODE

POLE

INSTALL 5 AMP QUICK DISCONNECT FOR R, 0, & G CONDUCTORS.


INSTALL UNFUSED QUICK DISCONNECT FOR W CONDUCTOR.
HEAT SHRINK CAP FORB CONDUCTOR. SEE STANDARD SPEC. 9-29.7
PULL QUICK DISCONNECTS TIGHT TO CONDUIT.

LEVELING NUT (TYP.) -SEE NOTE 4


TOP OF FOUNDATION

RAMP METER
SIGNAL STANDARD
ELECTRICAL DETAILS

SUPPLEMENTAL GROUNDING
CONDUCTOR - SEE NOTE 3
CONDUIT COUPLING - INSTALL FLUSH
WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

CLAMP CONDUCTOR TO
STEEL REINFORCING WITH
LISTED CONNECTOR
SUITABLE FOR USE
EMBEDDED IN CONCRETE

STANDARD PLAN J-22.16-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

DETAIL
FOUNDATION WIRING

ELECTRICAL CONDUIT TO JUNCTION BOX


- SEE CONTRACT PLANS FOR DIAMETER

Pasco Bakotich Ill

PERSPECTIVE VIEW

RAMP METER

.....

STATE DESIGN ENGINEER

6110113
DATE

~ Washington State Department of Transportation

GROUNDING CONDUCTOR NONINSULATED #4 AWG STRANDED


COPPER- PROVIDE 3' MIN. SLACK
(ROUTE CONDUCTOR TO GROUNDING
STUD)

TOP OF FOUNDATION LEVEL W/


SIDEWALK OR ABOVE SOIL SURFACE
-SEE STANDARD PLAN J-26.15
~
FOR PLACEMENT DETAILS
SIGNAL POLE

~j
~

TOP OF FOUNDATION LEVEL W/


SIDEWALK OR ABOVE SOIL SURFACE
-SEE STANDARD PLAN J-26.15
FOR PLACEMENT DETAILS

CONDUIT COUPLING -INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

GROUT WI 318'

DRAIN HOLE

GROUNDING CONDUCTOR NONINSULATED #4 AWG STRANDED


COPPER- PROVIDE 3' MIN. SLACK
(ROUTE CONDUCTOR TO GROUNDING
STUD)

~
SIGNAL POLE
I

CONDUIT COUPLING- INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

GROUT WI 3/8"
DRAIN HOLE

EARTH EMBANKMENT

3. Foundations are designed for Single Mast Arm Standards


and Double Mast Arm Standards with goo between arms.
Special foundation design is required for Double Arm
Standards where the angle between mast arms is other
than goo. For Double Mast Arm Standards with goo
between arms, use larger XYZ value for foundation depth
selection .

~-~~~ '-~~~ ~~~EE~u~~i~~i~Es


-

:::2; ',

:::2;

'".. ,

EXISTING GRADE

:----l 1 MAX.
.........._ I GROUND SLOPE

ANCHOR BOLTS & ANCHOR


=IF-i--1:'7~~7f"._

'tl-1-t--'"""---- PLATE SUPPLIED BY SIGNAL

POLE MANUFACTURER

#4 HOOPS@
1' - 0" CENTERS

LIMITS OF EXCAVATION
(TYP.)

ANCHOR BOLTS & ANCHOR


PLATE SUPPLIED BY SIGNAL
POLE MANUFACTURER
8-#8 BARS
EVENLY SPACED

8 -#8 BARS
EVENLY SPACED

SHORING OR EXTRA
EXCAVATION (TYP.)
CORRUGATED METAL PIPE

OR ROUND
OR 4' _ O" ROUND

OVER-EXCAVATED AREA SHALL BE BACKFILLED


WITH CONTROLLED-DENSITY FILL (CDF) OR WITH
SOIL IN ACCORDANCE WITH STD. SPEC. 8-20.3(2)

~~~~~TURBED

FOUNDATION REINFORCEMENT DETAIL

ALTERNATE # 1

q>

(TYP.)

non

GROUND SLOPE= 3H: 1V OR FLATTER


700

900

10'- 0"

10'- 0"

11'- 0" 11'- 0" 15'- 0"

18'- 0" 20'- 0" 20'- 0"

3' - 0" SQUARE 8'- 0"

8'- 0"

9'- 0"

4'- 0" ROUND

8'- 0"

8'- 0"

3'- 0" ROUND

8'- 0"

8'- 0"

3' - 0" SQUARE 7'- 0"


4'- 0" ROUND
3'- 0" ROUND

3'- 0" ROUND

2500 PSF
OR GREATER

1350

1500

1900

2300

2600

3000

ALLOWABLE LATERAL FOUNDATION


BEARING PRESSURE
TYPE

12'- 0"

9'- 0"

9'- 0"

10'- 0"

11'- 0"

12'- 0"

12'- 0"

4'- 0" ROUND

9'- 0"

11'- 0" 13'- 0"

15'- 0"

18'- 0"

18'- 0"

3'- 0" ROUND

7'- 0"

7'- 0"

8'- 0"

8'- 0"

9'- 0"

10'- 0"

10'- 0"

7'- 0"

7'- 0"

7'- 0"

8'- 0"

8'- 0"

9'- 0"

10'- 0"

10'- 0"

6'- 0"

6'- 0"

7'- 0"

8'- 0"

9'- 0"

11'- 0"

15'- 0"

15'- 0"

6'- 0"

6'- 0"

6'- 0"

7'- 0"

7'- 0"

8'- 0"

8'- 0"

4'- 0" ROUND

6'- 0"

6'- 0"

6'- 0"

7'- 0"

7'- 0"

8'- 0"

8'- 0"

2500 PSF
OR GREATER

1350

1500

GROUND SLOPE= 3H: 1V OR FLATTER


ALLOWABLE LATERAL FOUNDATION
BEARING PRESSURE
TYPE
1000 PSF
1500 PSF
2500 PSF
OR GREATER

1500

700

900

3'- 0" ROUND

10'- 0"

10'- 0"

11'- 0" 15'- 0" 20'- 0" 25'- 0" 28'- 0" 28'- 0"

4'- 0" ROUND

8'- 0"

8'- 0"

9'- 0"

1900

3'- 0" ROUND

8'- 0"

8'- 0"

11'- 0" 15'- 0"

18- 0"

21'- 0" 25'- 0" 25'- 0"

4'- 0" ROUND

7'- 0"

7'- 0"

7'- 0"

10'- 0"

13'- 0"

12'- 0" 13'- 0"


8'- 0"

2600

3000

SPECIAL FOUNDATION TYPE


11'- 0"

12'- 0"

14'- 0"

16'- 0"

18'- 0"

21'- 0"

21'- 0"

3' - 0" SQUARE 10'- 0"

10'- 0"

10'- 0"

11'- 0"

11'- 0"

12'- 0"

13'- 0"

13'- 0"

4'- 0" ROUND

10'- 0"

10'- 0"

10'- 0"

11'- 0"

11'- 0"

12'- 0"

13'- 0"

13'- 0"

3'- 0" ROUND

9'- 0"

9'- 0"

10'- 0"

12'- 0"

12'- 0"

14'- 0"

18'- 0"

18'- 0"

3' - 0" SQUARE

9'- 0"

9'- 0"

9'- 0"

9'- 0"

10'- 0"

10'- 0"

11'- 0"

11'- 0"

4'- 0" ROUND

9'- 0"

9'- 0"

9'- 0"

9'- 0"

10'- 0"

10'- 0"

11'- 0"

11'- 0"

3'- 0" ROUND

6'- 0"

6'- 0"

7'- 0"

11'- 0" 13'- 0"

4'- 0" ROUND

6'- 0"

6'- 0"

6'- 0"

6'- 0"

7'- 0"

2300
14'- 0"

2600
15'- 0"
15'- 0"

3000
15'- 0"
15'- 0"

18'- 0" 20'- 0" 20'- 0"


9'- 0"

9'- 0"

9'- 0"

ALLOWABLE LATERAL FOUNDATION


BEARING PRESSURE
TYPE

= 17

1000 PSF
1500 PSF
2500 PSF
OR GREATER

1350

900

1500

1900

2300

3'- 0" ROUND

SPECIAL FOUNDATION TYPE

4'- 0" ROUND

SPECIAL FOUNDATION TYPE

2600

3000

APPROVED FOR PUBLICATION

11'- 0"

11'- 0"

14'- 0"

18'- 0" 21'- 0" 24' -0"

28'- 0" 23'- 0"

4'- 0" ROUND

10'- 0"

10'- 0"

10'- 0"

11'- 0"

18'- 0" 18'- 0"

16'- 0"

3'- 0" ROUND

9'- 0"

9'- 0"

10'- 0"

14'- 0"

16'- 0" 21'- 0"

23'- 0" 23'- 0"

4'- 0" ROUND

9'- 0"

9'- 0"

9'- 0"

9'- 0"

10'- 0"

12'- 0" 12'- 0"

12'- 0"

STANDARD PLAN J-26.10-02


SHEET 1 OF 1 SHEET

3'- 0" ROUND

13'- 0"

Backfill with controlled-density fill or


compacted borrow in accordance with
Standard Specification 8-20.3(2).

SIGNAL STANDARD
FOUNDATION PLAN

XYZ (FT")
700

Place the concrete foundation.


After concrete has cured, remove the
entire paper or cardboard form portion.

GROUND SLOPE= GREATER THAN 3H: 1V TO 2H: 1V

XYZ (FT")
1350

2300

11'- 0"

ALTERNATE# 2 CORRUGATED METAL PIPE TYPE CONSTRUCTION


FOR LATERAL BEARING PRESSURE
2500 PSF & I'ZJ
23, 1500 PSF & I'ZJ
18' 1000 PSF & I'ZJ

1900

SPECIAL FOUNDATION TYPE

12'- 0"

3' - 0" SQUARE 6'- 0"

900

3' - 0" SQUARE

11'- 0"

1500 PSF

XYZ (FT")
700

SPECIAL FOUNDATION TYPE

10'- 0"

6'- 0"

= 26

3'- 0" ROUND

9'- 0"

1000 PSF

7. For design parameters between the values listed in Table,


depth requirements may be interpolated between the
values provided.

When the existing soil will not retain a vertical face, over-excavate the foundation area and install a 36" or 48" diameter corrugated metal (pipe) form.
The top of the corrugated metal form shall terminate 1 foot below final grade.
Continue forming to full height using paper or cardboard form to achieve a
smooth finish on final exposed cement concrete. Support the form as
necessary to remain plumb.

GROUND SLOPE = GREATER THAN 3H : 1V TO 2H : 1V

XYZ (FT")

6. The top 2 feet of the foundation shall use a smooth


form (such as paper or cardboard). After the concrete
has cured, this entire form shall be removed.

METAL (SUBSURFACE) FORM REQUIRED

TABLE

5. Foundations constructed within Ecology Embankments


shall be increased in depth by the depth of the Ecology
Embankment.

ALTERNATE #2 - CONSTRUCTION METHOD

ALTERNATE# 1 DRILLED SHAFT-TYPE CONSTRUCTION


FOR LATERAL BEARING PRESSURE
2500 PSF & I'ZJ
34, 1500 PSF & I'ZJ
28, 1000 PSF & I'ZJ

4. Foundations not within the parameters of this standard


require Special Design. Contact the WSDOT Bridge and
Structures Office through the Engineer for Special
Foundation Designs.

8. Install Signal Foundation Identification Tag. See


Standard Plan J-26.15 for details.

ALTERNATE # 2

CONDUIT SIZE AND QUANTITY AS SHOWN IN THE CONTRACT;


CAP BOTH ENDS
CLAMP CONDUCTOR TO STEEL REINFORCING WITH LISTED
CONNECTOR SUITABLE FOR USE EMBEDDED IN CONCRETE
PAPER OR CARDBOARD FORM SHALL NOT STAY-IN-PLACE

FOUNDATION DEPTH

ALLOWABLE LATERAL FOUNDATION


TYPE
BEARING PRESSURE

UNDISTURBED EARTH
(TYP.)

ROUND

FOUNDATION REINFORCEMENT AND BACKFILL DETAIL


~CONCRETE CAST WITHIN A CORRUGATED METAL PIPE STAY-IN-PLACE FORM

CONCRETE CAST DIRECTLY AGAINST UNDISTURBED EARTH, DRILLED SHAFT

1500 PSF

1. This structure has been designed according to the Fifth


Edition 2oog AASHTO Standard Specifications for
Structural Supports for Highway Signs, Luminaires and
Traffic Signals. Basic wind velocity is go mph, Design
Life/Recurrence Interval 50 years, and Fatigue Category Ill.
2. Foundations are designed for Type II, Ill, and SD Signal
Standards with a maximum mast arm length of 65'.

C\1

1000 PSF

NOTES

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

03-15-12
DATE

. . . Washington State Department of Transportation

3/8" PREMOLDED
JOINT FILLER
TOP OF FOUNDATION
LEVEL WITH GRADE
SEE TYPICAL
SECTION FOR
REINFORCEMENT

3'- 0"

SIDEWALK
NOT STEEPER
THAN 1.5H : 1V

FINSHED GRADE
SLOPE= FLAT TO 2H: 1V
(4H : 1V SLOPE SHOWN)

NOTE

= 2'- 0" FOR 3'- 0" DIAM. FOUNDATION


2'- 6" FOR 4'- 0" DIAM. FOUNDATION
2'- 6" FOR 3'- 0" SQUARE FOUNDATION

<!)

3'- 0"

FINISHED GRADE
SLOPE= FLAT TO 10H: 1V
(10H: 1V SLOPE SHOWN)
SIGNAL STANDARD FOUNDATION
-SEE STANDARD PLAN J-26.10

<!)

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

(SHOWN REDUCED)
PLAN

SECTION

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

PLAN

FOUNDATION IN OR NEAR SIDEWALK

ELEVATION
EXISTING GRADE OR FILL SLOPE= FLAT TO 10H: 1V

CASE A

CASEB

ii

NOT STEEPER THAN 1.5H : 1V

LL

~
I-

FINISHED GRADE
SLOPE= STEEPER THAN 3H: 1V
BUT NOT STEEPER THAN 2H : 1V

<!)
u

ii

~
I-

NOT STEEPER THAN 2H : 1V


FINISHED GRADE
SLOPE= 3H: 1V OR FLATTER
BUT NOT FLATTER THAN 10H: 1V

<!)

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

SIGNAL STANDARD
FOUNDATION- SEE
STANDARD PLAN J-26.10

SIGNAL STANDARD FOUNDATION


-SEE STANDARD PLAN J-26.10

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%
ELEVATION

PLAN

EXISTING GRADE OR FILL SLOPE = > 3H : 1V TO 2H : 1V

CASED

SIGNAL STANDARD
FOUNDATION PLACEMENTS
STANDARD PLAN J-26.15-01
SHEET 1 OF 3 SHEETS

ELEVATION

PLAN

EXISTING GRADE OR FILL SLOPE= 10H: 1V TO :S 3H: 1V

CASEC

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

05117112
DATE

. . . Washington State Department of Transportation

...................................

SIGNAL STANDARD FOUNDATION

EXISTING GRADE OR CUT SLOPE


SLOPE= FLAT TO 2H: 1V
(MAX. SLOPE SHOWN)

3/8" PREMOLDED
JOINT FILLER

E STANDARD PLAN J-26,:~'~,

SLOPE TO MEET
FINISHED GRADE
- SEE SECTIONS
FOR SLOPE

TOP OF FOUNDATION
LEVEL WITH GRADE

'

/"

!
-tf

SIDEWALK

'

----------~------..................

-......_

-rn~
~\
--

'\

......__

I.

'\

'I

~t-

\1/n//
\
'&
~
/
/~'
c],
\

TOP OF FOUNDATION
LEVEL WITH GRADE

"-------... __ 1
______ ...

0+

/,/

~
I-

SIGNAL STANDARD FOUNDATION


-SEE STANDARD PLAN J-26.10

.I

(-~~j.:_);~1~:'~6~-:

7---- f''

G)

-----///

= 2'- 0" FOR 3'- 0" DIAM. FOUNDATION


2'- 6" FOR 4'- 0" DIAM. FOUNDATION
2'- 6" FOR 3'- 0" SQUARE FOUNDATION

SLOPE TO DRAIN AWAY FROM THE FOUNDATION


SLOPE NOT STEEPER THAN 5%

(SHOWN REDUCED)

SECTION

PLAN

'

EXISTING GRADE OR CUT SLOPE FLAT TO 10H: 1V


CASEF

',,
'

\ .. - . . . . _

\,,

'.,

', ____

.............

//

-,_________,______............

............

.............

SIGNAL STANDARD FOUNDATION


- SEE STANDARD PLAN J-26.1 0

................

NOT STEEPER
THAN2H: 1V

BACK SLOPE

.....................

;'~'... 0

___ /,/ 0

------------------------

SIGNAL STANDARD FOUNDATION


-SEE STANDARD PLAN J-26.10

--PLAN

SLOPE TO MEET FINISHED GRADE


- SEE SECTIONS FOR SLOPE

NOT STEEPER
THAN 1.5H : 1V

'',

~(!ffi):

I-

EXISTING GRADE OR CUT SLOPE


SLOPE STEEPER THAN
3H : 1V (2H : 1V MAX.)
(MAX. SLOPE SHOWN)

---x--- -SEE
STANDARD
PLAN J-26.10

/,.,..--,

G)

.................

-----------ELEVATION

EXISTING GRADE OR CUT SLOPE 10H : 1V TO S 3H : 1V


CASEG

-----

...........................

PLAN

-------SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

. . ~6"u~A~T~~'f."E

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

EXISTING GRADE OR CUT SLOPE


EXISTING SLOPE STEEPER
THAN 10H : 1V TO!> 3H : 1V
(MAX. SLOPE SHOWN)
TOP OF FOUNDATION
SIGNAL STANDARD LEVEL WITH GRADE
FOUNDATION

................----------------.... _

//

_____

------

ELEVATION

FOUNDATION IN OR NEAR SIDEWALK


CASEE

/_----

.. ____

STANDARD PLAN J-26.10

PLAN

G)

3~--o_ J__ / _/

I.

FLAT TO 10H: 1V
(MAX. SLOPE SHOWN)

()

u:::

..=

EX6~~~~~~

IJ

NOT STEEPER
THAN 2H : 1V

3~

BACK SLOPE \

G)

---

---

ELEVATION

SLOPE TO DRAIN AWAY


FROM THE FOUNDATION
SLOPE NOT STEEPER THAN 5%

EXISTING GRADE OR CUT SLOPE STEEPER THAN 3H : 1V (2H : 1V MAX.)


CASEH

SIGNAL STANDARD
FOUNDATION PLACEMENTS
STANDARD PLAN J-26.15-01
SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

05117112
DATE

. . . Washington State Department of Transportation

CEMENT CONCRETE SIDEWALK


-SEE STANDARD PLAN F-30.10
TRAFFIC ISLAND- SEE
CONTRACT PLAN SHEETS
F=========t~dF~OR DETAILS

SEE TYPICAL SECTION FOR REINFORCEMENT

<

SIGNAL STANDARD FOUNDATIONSEE STANDARD PLAN J-26.10

CEMENT CONCRETE SIDEWALK


-SEE STANDARD PLAN F-30.10

4'- 6" MIN.


**

OR ASP~CRETE PAVEMENT
4'- 6" MIN. FROM THE FACE
OF THE POLE TO THE BACK OF
THE CURB OR EDGE OF SHOULDER

SEE TYPICAL SECTION


FOR REINFORCEMENT

\\

3/8" PREMOLDED JOINT FILLER

SEE TYPICAL SECTION FOR


REINFORCEMENT

SEE TYPICAL SECTION


FOR REINFORCEMENT

CEMENT CONCRETE SIDEWALK


-SEE STANDARD PLAN F-30.10
OR ASPHALT CONCRETE PAVEMENT
3/8" PREMOLDED
JOINT FILLER

\\

3/8" PREMOLDED
JOINT FILLER

NOTE
*

SIGNAL STANDARD
FOUNDATION- SEE
STANDARD PLAN J-26.10

3/8" PREMOLDED
JOINT FILLER

*=APPLIES TO THE SIDE OF THE FOUNDATION WHEN


PEDESTRIAN PUSH BUTTON IS TO BE INSTALLED.

FOUNDATION PARTIALLY WITHIN


SIDEWALK SECTION

L---.;.;;..;-.,~---J 4'- 6" MIN.

SIGNAL STANDARD
FOUNDATION- SEE
STANDARD PLAN J-26.10

TO FACE OF
STANDARD

FOUNDATION WITHIN SIDEWALK


OR TRAFFIC ISLAND SECTION

DUAL PEDESTRIAN PUSH BUTTON

NOTE
NOTE
*

REFER TO CONTRACT DOCUMENTS FOR PROJECT SPECIFIC


INTERSECTION LAYOUTS & TRAFFIC ISLAND MATERIAL TYPE

SIGNAL STANDARD
FOUNDATION- SEE
STANDARD PLAN J-26.10

= 2'- 0" FOR 3'- 0" DIAM. FOUNDATION


2'- 6" FOR 4'- 0" DIAM. FOUNDATION
2'- 6" FOR 3'- 0" SQUARE FOUNDATION

FOUNDATION PARTIALLY
WITHIN SIDEWALK SECTION

SINGLE PEDESTRIAN PUSH BUTTON

GROUNDING CONDUCTOR NON-INSULATED


#4 AWG STRANDED COPPER- PROVIDE 3' MIN.
SLACK (ROUTE CONDUCTOR TO GROUNDING STUD)

PROVIDE 3/8" DIAMETER DRAIN TUBE


IN THE GROUT PAD

FOUNDATION OUTSIDE THE SIDEWALK SECTION

SIGNAL FOUNDATION

APPLY GROUT EVEN WITH THE


BOTTOM OF THE ANCHOR PLATE
AFTER PLUMBING THE STANDARD

WWF 4 X 4- w 2.9 X 2.9 AT CENTER


OF EXTENDED SIDE WALK AT
SIGNAL STANDARD FOUNDATION

10 GAGE STAINLESS STEEL TAGRECESS FLUSH WITH TOP OF


FINISHED FOUNDATION

FORM TO FINISH GRADE WHEN INSTALLING


SIDEWALK OR TRAFFIC ISLAND
3/8" PREMOLDED JOINT FILLER

SEE CONTRACT PLANS FOR


FOR EXTENDED SIDEWALK
LAYOUT

SIDEWALK OR
TRAFFIC ISLAND

1 : : : , IDENTIFICAT::::STANDARD
12-28 (NF) x 2" LONG STAINLESS STEEL
SCREW- DRILL AND TAP FROM BOTTOM,
LEAVE SCREW FLUSH WITH TOP. APPLY
LOCKTITE TO SCREW THREADS TO BIND
SCREWS AND I.D. TAG TOGETHER

HAND HOLE
L~~---

ROUGHENED
CONCRETE SURFACE
FOUNDATION

1
~
.....
z
N

~
.....

a.:

3/8" MIN
(TYP.)
0.05" MIN.
(TYP.)

SIGNAL STANDARD FOUNDATION


-SEE STANDARD PLAN J-26.10

FOUNDATION
11'
DEPTH
RD;........ SQUARE OR ROUND
SHAPE
36"........ DIAMETER OR WIDTH
DIMENSION
1 ......... ALTERNATE 1 OR 2- SEE
ALT.#
STANDARD PLAN J-26.10

OBLIQUE VIEW
REINFORCING AND ANCHOR BOLTS
NOT SHOWN FOR CLARITY
(GROUT PAD OPTION SHOWN)

CLAMP CONDUCTOR TO STEEL REINFORCING


WITH LISTED CONNECTOR SUITABLE FOR USE
EMBEDDED IN CONCRETE

SIGNAL FOUNDATION
IDENTIFICATION TAG DETAIL
TEXT SHALL BE ENGRAVED 0.014" DEEP

. .

I
I
I

I
I
I

I I
I I
I I
II

I
I
I
I

. :: ~~~~~~~~~4~

SIGNAL STANDARD
FOUNDATION PLACEMENTS
STANDARD PLAN J-26.15-01
SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

NOTE
FOUNDATION REINFORCING ONLY PARTIALLY SHOWN FOR CLARITY.
-SEE STANDARD PLAN J-26.10 FOR DETAILS NOT SHOWN.

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

05117112
DATE

. . . Washington State Department of Transportation

TYPICAL SECTION

TOP OF FOUNDATION LEVEL W/


f.'
SIDEWALK OR ABOVE SOIL SURFACE
-SEE STANDARD PLAN J-26.15
'1:.
FOR PLACEMENT DETAILS
STRAIN POLE

GROUNDING CONDUCTOR NON-INSULATED

#4 AWG STRANDED COPPER - PROVIDE


3' MIN. SLACK (ROUTE CONDUCTOR TO
GROUNDING STUD)

~j

1:::!

.....

TOP OF FOUNDATION LEVEL W/


SIDEWALK OR ABOVE SOIL SURFACE
-SEE STANDARD PLAN J-26.15
FOR PLACEMENT DETAILS

#4 AWG STRANDED COPPER- PROVIDE

STRAIN POLE

3' MIN. SLACK (ROUTE CONDUCTOR TO


GROUNDING STUD)

GROUT WI 3/8"
DRAIN HOLE

CONDUIT COUPLING - INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

GROUT W/318'
DRAIN HOLE

GROUNDING CONDUCTOR NON-INSULATED

ct

CONDUIT COUPLING- INSTALL FLUSH


WITH TOP OF FOUNDATION (DO NOT
GLUE PVC STUBOUT)

-----------------,-,~~~ d~

~ ~::::!;__ I~ ~

...___ _ __ L _

--.....__<

EARTH EMBANKMENT
AS REQUIRED -SEE
PLACEMENT DETAILS

~.'),~~.":6'~~~

PLACEMENT DETAILS
~ EXISTING GRADE

EXISTING GRADE

:----l 1 MAX.

-......__

I GROUND SLOPE
ANCHOR BOLTS & ANCHOR

ANCHOR BOLTS & ANCHOR

4--l=-_,;,--=l~ti-!49;;9~L PLATES SUPPLIED BY SIGNAL

=1-=II~~L PLATES SUPPLIED BY SIGNAL

POLE MANUFACTURER

POLE MANUFACTURER

8 -#8 BARS
EVENLY SPACED

8-#8 BARS
EVENLY SPACED

OVER-EXCAVATED AREA SHALL BE BACKFILLED


WITH CONTROLLED-DENSITY FILL (CDF) OR WITH
SOIL IN ACCORDANCE WITH STD. SPEC. 8-20.3(2)

FOUNDATION REINFORCEMENT DETAIL

0
0

ROUND

CLAMP CONDUCTOR TO STEEL REINFORCING WITH LISTED


CONNECTOR SUITABLE FOR USE EMBEDDED IN CONCRETE

GROUND SLOPE = 3H : 1V TO 2H : 1V

1000 PSF

1500 PSF

2500 PSF
OR GREATER

11'- 0"

13'- 0"

15'- 0" 16'- 0" 18'- 0"

19'- 0" 20'- 0"

3' - 0" SQUARE 11'- 0"

13'- 0"

15'- 0" 16'- 0" 18'- 0"

19'- 0" 20'- 0"

4'- 0" ROUND

10'- 0"

11'- 0"

13'- 0" 15'- 0" 15'- 0"

16'- 0"

18'- 0"

3'- 0" ROUND

9'- 0"

11'- 0"

12'- 0" 14'- 0" 15'- 0"

15'- 0"

16'- 0"

3' - 0" SQUARE 9'- 0"

11'- 0"

12'- 0" 14'- 0" 15'- 0"

15'- 0"

16'- 0"

4'- 0" ROUND

8'- 0"

9'- 0"

10'- 0" 12'- 0" 13'- 0"

13'- 0"

3'- 0" ROUND

7'- 0"

8'- 0"

9'- 0"

10'- 0" 11'- 0"

3' - 0" SQUARE 7'- 0"

8'- 0"

9'- 0"

4'- 0" ROUND

7'- 0"

8'- 0"

6'- 0"

1000 PSF

POLE CLASS- RESULTANT HORIZONTAL TENSION (LBS)


1900

2700

3700

4800

5600

6300

3'- 0" ROUND

SPECIAL FOUNDATION TYPE

3' - 0" SQUARE

SPECIAL FOUNDATION TYPE

4'- 0" ROUND

SPECIAL FOUNDATION TYPE


12'- 0"

13'- 0"

15'- 0"

16'- 0"

16'- 0"

17'- 0"

12'- 0"

13'- 0"

15'- 0"

16'- 0"

16'- 0"

17'- 0"

14'- 0"

4'- 0" ROUND

9'- 0"

10'- 0"

11'- 0"

13'- 0"

14'- 0"

14'- 0"

15'- 0"

12'- 0"

13'- 0"

3'- 0" ROUND

8'- 0"

9'- 0"

10'- 0"

11'- 0"

12'- 0"

13'- 0"

14'- 0"

10'- 0" 11'- 0"

12'- 0"

13'- 0"

3' - 0" SQUARE

8'- 0"

9'- 0"

10'- 0"

11'- 0"

12'- 0"

13'- 0"

14'- 0"

9'- 0"

10'- 0"

11'- 0"

4'- 0" ROUND

7'- 0"

8'- 0"

9'- 0"

10'- 0"

11'- 0"

11'- 0"

12'- 0"

2500 PSF
OR GREATER

ALTERNATE# 2 CORRUGATED METAL PIPE TYPE CONSTRUCTION - DEPTH "On


FOR LATERAL BEARING PRESSURE= 2500 PSF & (ZJ = 23, 1500 PSF & (ZJ = 18, 1000 PSF & (ZJ = 17
GROUND SLOPE= 3H: 1V OR FLATTER

GROUND SLOPE = 3H : 1V TO 2H : 1V

ALLOWABLE LATERAL FOUNDATION POLE CLASS- RESULTANT HORIZONTAL TENSION (LBS) ALLOWABLE LATERAL FOUNDATION
TYPE
TYPE
BEARING PRESSURE
BEARING PRESSURE
1900
2700
3700
4800
7200
5600
6300
1000 PSF
1500 PSF
2500 PSF
OR GREATER

3'- 0" ROUND

11'- 0"

13'- 0"

15'- 0" 16'- 0" 18'- 0"

19'- 0" 20'- 0"

4'- 0" ROUND

10'- 0"

11'- 0"

13'- 0" 15'- 0" 15'- 0"

16'- 0"

18'- 0"

3'- 0" ROUND

9'- 0"

11'- 0"

12'- 0" 14'- 0" 15'- 0"

15'- 0"

16'- 0"

4'- 0" ROUND

8'- 0"

9'- 0"

10'- 0" 12'- 0" 13'- 0"

13'- 0"

14'- 0"

3'- 0" ROUND

7'- 0"

8'- 0"

9'- 0"

10'- 0" 11'- 0"

12'- 0"

13'- 0"

4'- 0" ROUND

6'- 0"

7'- 0"

8'- 0"

9'- 0"

10'- 0"

11'- 0"

10'- 0"

UNDISTURBED EARTH
(TYP.)

6. See Standard Plan J-27.15 for Strain Pole


Standards Type IV and V details.
7. Install Signal Foundation Identification Tag. See
Standard Plan J-26.15 for details.

1000 PSF
1500 PSF
2500 PSF
OR GREATER

POLE CLASS- RESULTANT HORIZONTAL TENSION (LBS)


1900

2700

3700

4800

5600

6300

3'- 0" ROUND

SPECIAL FOUNDATION TYPE

4'- 0" ROUND

SPECIAL FOUNDATION TYPE

When the existing soil will not retain a vertical face, over-excavate the
foundation area and install a 36" or 48" diameter corrugated metal
{pipe) form. The top of the corrugated metal form shall terminate
1 foot below final grade. Continue forming
to full height using a paper or cardboard form
to achieve a smooth finish on final exposed
cement concrete. Support the form as
necessary to remain plumb.
Place the concrete foundation.

10'- 0"

10'- 0"

3'- 0" ROUND

7200

3' - 0" SQUARE 10'- 0"

1500 PSF

4. Foundations constructed within Ecology Embankments shall be increased in depth by the depth of
the Ecology Embankment.

METAL (SUBSURFACE) FORM REQUIRED

ALTERNATE# 1 DRILLED SHAFT-TYPE CONSTRUCTION - DEPTH "D"


FOR LATERAL BEARING PRESSURE= 2500 PSF & (ZJ = 34, 1500 PSF & (ZJ = 28, 1000 PSF & (ZJ = 26

3'- 0" ROUND

3. Foundations not within the parameters of this


standard require Special Design. Contact the
WSDOT Bridge and Structures Office through
the Engineer for Special Foundation Designs.

ALTERNATE #2 - CONSTRUCTION METHOD

~ PAPER OR CARDBOARD FORM SHALL NOT STAY-IN-PLACE

GROUND SLOPE= 3H: 1V OR FLATTER

Pole Standards with a maximum mast arm length


of 16'- 0" .

ALTERNATE #2

CONDUIT SIZE AND QUANTITY AS SHOWN IN THE CONTRACT;


CAP BOTH ENDS

ALLOWABLE LATERAL FOUNDATION POLE CLASS- RESULTANT HORIZONTAL TENSION (LBS) ALLOWABLE LATERAL FOUNDATION
TYPE
TYPE
BEARING PRESSURE
BEARING PRESSURE
1900
2700
3700
4800
5600
6300
7200

2. Foundations are designed for Type IV and V Strain

CORRUGATED METAL PIPE

FOUNDATION REINFORCEMENT AND BACKFILL DETAIL


~CONCRETE CAST WITHIN A CORRUGATED METAL PIPE STAY-IN-PLACE FORM

CONCRETE CAST DIRECTLY AGAINST UNDISTURBED EARTH, DRILLED SHAFT

ALTERNATE #1

MIN.
(TYP.)

1. This structure has been designed according to


the Fifth Edition 2009 MSHTO Standard
Specifications for Structural Supports for Highway
Signs, Luminaires, and Traffic Signals: Basic wind
velocity 90 mph, Design Life/Recurrence Interval
50 years, and Fatigue Category Ill.

5. The top 2 feet of the foundation shall use a smooth


form {such as paper or cardboard). After the
concrete has cured, this entire form shall be
removed.

SHORING OR EXTRA
EXCAVATION (TYP.)

OR ROUND
OR 4'- 0" ROUND

NOTES

7200

After concrete has cured, remove the


entire paper or cardboard form portion.
Backfill with controlled-density fill or
compacted borrow in accordance with
Standard Specification 8-20.3(2).

TYPE IV AND V STRAIN


POLE FOUNDATION
STANDARD PLAN J-27.10-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

3'- 0" ROUND

10'- 0"

12'- 0"

13'- 0"

15'- 0"

16'- 0"

16'- 0"

17'- 0"

4'- 0" ROUND

9'- 0"

10'- 0"

11'- 0"

13'- 0"

14'- 0"

14'- 0"

15'- 0"

3'- 0" ROUND

8'- 0"

9'- 0"

10'- 0"

11'- 0"

12'- 0"

13'- 0"

14'- 0"

4'- 0" ROUND

7'- 0"

8'- 0"

9'- 0"

10'- 0"

11'- 0"

11'- 0"

12'- 0"

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

03-15-12
DATE

. . . Washington State Department of Transportation

NOTES

STRAIN POLE DIMENSION CHART


1goo
LB

2700
LB

3700
LB

4800
LB

5600
LB

6300
LB

7200
LB

1/4

5/16

5/16

5/16

5/16

1. This structure has been designed according to the Fifth Edition 2009 MSHTO Standard
Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals:
Basic wind velocity 90 mph, Design Life/Recurrence Interval 50 years, and Fatigue
Category Ill.

15"

17"

1g"

20"

20"

22"

22"

2. 2 1/2" diameter weatherhead may be substituted for the elbow and nipple assembly.

15"

17"

1g"

20"

20"

22"

22"

3. Pole shaft shall have 0.14" ft/taper.

11"

12 1/2"

14"

14"

15"

16"

17"

4. See Standard Plan J-15.15 for Span Wire Installation details.

1 1/2"

1 1/2"

1 1/2"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 1/4"

11/2"

1 1/2"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

POLE CLASS (Resultant Horizontal Tension)


KEY

ITEM
POLE GAGE OR THICKNESS
BASE PLATE

ANCHOR BOLT CIRCLE DIAM.

POLE BASE DIAMETER

BASE PLATE THICKNESS

ANCHOR BOLT DIAMETER

5. Hand holes may be 6" x 4", oval or rectangle. Provide a "J" or "C" hook at 90 or 180
off upper hand hole.

* MINIMUM REQUIRED DIMENSION- CONTRACTOR MAY REVISE WITH ENGINEER APPROVAL

1" PLATE
CENTERED

3/16

CONE SECTION
DETAIL

6. See Standard Plan J-27.10 for Type IV and V Strain Pole Foundation.

BASE PLATE

MAST ARM LENGTH AS NOTED IN CONTRACT

1/2" STEEL BOLT, 1 1/2" LONG


WITH WASHER AND NUT FOR GROUND

c::c

=
~

11i0
o::z
::cw

I- ....I

5/8" DIAMETER x 3 1/2"


HEAVY HEX BOLT
AND NUT (5 EACH
PER CLAMP)

4"

6 HEX NUTS AND


6 PLAIN WASHERS
REQUIRED PER BOLT

RADIUS AS
REQUIRED

REMOVABLE RAINTIGHT
HAND HOLE COVER WITH
GASKET- FASTEN WITH
2 STAINLESS STEEL
(ASTM F-5g2) SCREWS

ANCHOR BOLT &


ANCHOR PLATE (TYP.)
SUPPLIED BY SIGNAL
POLE MANUFACTURER

40'- 0" OR 50'- 0"


FROM LIGHT SOURCE
TO BASE PLATE
(SEE CONTRACT)

1 1/8" (TYP.)

1" THICK ANCHOR BOLT


ANCHOR PLATE2 REQUIRED

270
3/8" THICK (A36)
STEEL CLAMP

ALL HAND HOLES 180

1" DIAMETER X 1"


SCHEDULE80
PIPE SLEEVE

0 LUMINAIRE AND
WIREWAY

go
WIREWAY

ANCHOR BOLT
DIAM. + 1/8" (TYP.)

ATTACHMENT POINT ANGLES

....1

CABLE CONNECT
BOLT

STRAIN CLAMP
DETAIL

CONE SECTION
(SEE DETAIL)

HAND HOLE DETAIL


(SEE NOTE 5)

REMOVABLE CAP

WIREWAYTWOPERPOLE
(SEE DETAIL)
ANCHOR BOLT
DIAMETER+ 1/4"
(TYP.)

ANCHOR PLATE2 REQUIRED

Cll

ANCHOR BOLT AND


ANCHOR PLATE ASSEMBLY
DETAIL

2 1/2" SPLIT COUPLING

2 1/2" DIAMETER
ELBOW(SEE
NOTE 2)

POLE
WALL

2 1/2" DIAMETER
CHASE NIPPLE
2 1/2" DIAMETER
SHORT NIPPLE

en'
w
0::
b

STRAIN CLAMP ONE PER CABLE


CONNECTION (SEE
DETAIL)

STRAIN CLAMP- ONE


PER CABLE CONNECTION
(SEE DETAIL)

HAND HOLE (TYP.)


(SEE DETAIL)- PROVIDE
A "J" OR "C" HOOK AT
go OR 180 OFF
UPPER HAND HOLE

'
0

(')

HAND HOLE (TYP.) (SEE DETAIL)PROVIDE A "J" OR "C" HOOK AT


go OR 180 OFF UPPER HAND HOLE

b
'

TYPE IV AND V STRAIN


POLE STANDARD

WIREWAY DETAIL

STANDARD PLAN J-27.15-00


_L_ ,....-'-------;

FOR3GAGE
FOR 1/0GAGE

SHEET 1 OF 1 SHEET
BASE PLATE
(SEE DETAIL)

=
.....

f
BASE PLATE DETAIL

TYPEV
STANDARD

BASE PLATE
(SEE DETAIL)

=
.....
.....

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

TYPE IV
STANDARD

.....

STATE DESIGN ENGINEER

03-15-12
DATE

. . . Washington State Department of Transportation

NOTES

POLE

ct
MAST ARM LENGTH

MAST ARM LENGTH

1. This plan depicts the Steel Light Standard types and


terms commonly referred to in the Contract. All Steel
Light Standards are fabricated in accordance with the
Standard Specifications and the Contract Provisions.

GUSSET PLATE
I

POLE

POLE

ct
I

MAST ARM LENGTH

MAST ARM LENGTH


LUMINAIRE
HEAD

::::: 6.0' R.
(TYP.)

ct

2. The Luminaire Pole height shall not exceed 50' (H1).

3. Slip Bases shall not be installed on 50' (H1) poles


with Double Mast Arms, nor on poles weighing more
than 1000 lbs.

'

~~=------1-------.---

MAST ARM
BOLT CONNECTION
MAST ARM

::::: 6.0' R.

VARIES1.0' TO 2.0' R.

DOUBLE TYPE 1 MAST ARM

BOLT CONNECTION

4. The optimal location of the Luminaire head is over


the edge of the traveled way. Based on the placement of the Steel Light Standard foundation, the
position of the Luminaire head may vary. See
Standard Plan J-28.22.
5. Light Standard mast arm orientation is typically
perpendicular to roadway centerline.

BOLT CONNECTION

6. See Standard Plan J-28.50 for Hand Hole details.

POLE

ct
MAST ARM LENGTH

MAST ARM LENGTH

1-

1-

::c

::c

(!)

(!)

iii

::c
(!)
z
i=
z
::::>

0
:::2:

iii

.....
::c

::c
(!)
z
i=
z

GUSSET PLATE

::::>

LUMINAIRE POLE

.....
::c
LUMINAIRE POLE

0
:::2:
VARIES1.0' TO 2.0' R. (TYP.)
BOLT CONNECTION

EDGE OF
TRAVELED WAY

EDGE OF
TRAVELED WAY
VARIES WITH

DOUBLE TYPE 2 MAST ARM

OFFSET DISTANCE
SHOULDER

VARIES WITH
OFFSET DISTANCE
SHOULDER

POLE BASE

POLE BASE
HAND
HOLE

HAND
HOLE

BOTTOM OF
POLE BASE
STEEL LIGHT STANDARD FOUNDATION
- SEE STANDARD PLAN J-28.30

BOTTOM OF
POLE BASE
STEEL LIGHT STANDARD FOUNDATION
- SEE STANDARD PLAN J-28.30

STEEL LIGHT STANDARD


STANDARD PLAN J-28.10-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

LIGHT STANDARD

LIGHT STANDARD

WITH TYPE 1 (DAVIT) MAST ARM

WITH TYPE 2 (ELBOW) MAST ARM

(SLIP BASE SHOWN)

(SLIP BASE SHOWN)

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

POLE

POLE

POLE

MAST ARM LENGTH

~
MAST ARM LENGTH

LUMINAIRE HEAD
MAST ARM LENGTH
LUMINAIRE HEAD (TYP.)

(12' MAX. FOR SINGLE ARM


, 8' MAX. FOR DOUBLE ARM)

BOLT CONNECTION

LUMINAIRE HEAD
::::: 6.0' R. (TYP.)
::::: 6.0' R.

BOLT CONNECTION
BOLT CONNECTION

LUMINAIRE POLE
1J:

(!)

......

......
J:

(!)

jjj
J:

jjj
J:

J:

(!)

LUMINAIRE POLE

z
i=
z
::::>
0

......
J:

1J:

LUMINAIRE POLE

(!)

z
i=
z
::::>
0
::::!:

::::!:

EDGE OF
TRAVELED WAY
VARIES WITH
OFFSET DISTANCE
HAND HOLE

SHOULDER
HAND HOLE

HAND HOLE

STEEL LIGHT STANDARD


BARRIER MOUNTED BASE
- SEE STD. PLAN J-28.60,
C-8b, AND C-85.14

BOTTOM OF
POLE BASE
LIGHT STANDARD BASE
MOUNTED ON BRIDGE
- SEE STD. PLAN J-28.45

STEEL LIGHT STANDARD


BRIDGE-MOUNTED LUMINAIRE
(TYPE 1 MAST ARM SHOWN)

MEDIAN BARRIER-MOUNTED LUMINAIRE


(TYPE 1 MAST ARM SHOWN)

POST TOP-MOUNTED LUMINAIRE

STANDARD PLAN J-28.10-01


SHEET 2 OF 2 SHEETS

(SLIP BASE SHOWN)


APPROVED FOR PUBLICATION

Pasco Bakotich Ill


.....
fll

STATE DESIGN ENGINEER

05-11-11
DATE

'
'
Wash1ngton
State Department o fT ransportat1on

NOTES

rn
z

1. The Steel Light Standard Placement depicted on this plan is only intended for installations where roadside conditions allow its usage. Roadside conditions may require
a special design by the Bridge Office, as determined by the Project Engineer.

w
w

0::
ID
....1
....1

iii

1ii
z

Cl

2. See Standard Plan J-28.30 for foundation details and construction methods.
SEE TAPER NOTE

3. See Standard Plan J-28.50 for pole base and hand hole details.
4.5'

20.0'
SEE TAPER NOTE

END TAPER - FOR OPPOSING TRAFFIC


(SEE TAPER NOTE)

--- -

TOE OF EMBANKMENT WIDENING FOR


END TAPER FOR OPPOSING TRAFFIC ~
(SEE TAPER NOTE)

_t _{.. __ . __

-/I

- --

\
\
\

...........

.......

........
.......
....

4.5'

,
I

------

/
/
/
/
/

/
/
/

FOUNDATION

End Taper (on approach from opposing traffic):

-...__/

TAPER NOTE
TOE OF EMBANKMENT WIDENING

-- ---

2o' (longitudinal)

use on one-way roadways or where the Light Standard


is not in the Design Clear Zone of the opposing traffic .

6H:1V min. taper

use when the Light Standard is in the Design Clear


Zone of the opposing traffic .

--

/
/
/

/
///

_ _....-:::_:-::c_---------------------------------------- __./ ------------------------- ------------------ ....1

t3

0:::

FILL MATERIAL

MAST ARM

EDGE OF TRAVELED WAY

TRAFFIC

PLAN VIEW

CASESA&B

EMBANKMENTS

BASED ON FIELD CONDITIONS, STEEL LIGHT STANDARD


PLACEMENT CAN BE ADJUSTED 4.0', WHEN
APPROVED BY THE PROJECT ENGINEER.

SEE TAPER NOTE

STEEL LIGHT STANDARD


PLACEMENT (SLIP BASE)
FILL MATERIAL

....

MAST ARM

EDGE OF TRAVELED WAY

STANDARD PLAN .J-28.22-00


SHEET 1 OF 2 SHEETS

TRAFFIC

PLAN VIEW

CASEC

DITCH SECTIONS

APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

08-07-07
DATE

State Department of Transportation

rn
z

VARIES WITH

w
0::
w

3.0' MIN.

EDGE OF
SHOULDER

ID

....1
....1

VARIES WITH

1ii
z

HAND HOLE

NOT STEEPER THAN


10H:1V SLOPE

=:::::;:~~~?J2/7:'7::r~~~'77"n4~~

NOT STEEPER THAN


10H:1V SLOPE

SLOPE ROUNDING

=;;;~??lm/77:J:""""~~LJ

SLOPE ROUNDING

Cl

EDGE OF
SHOULDER

HAND HOLE

iii

3.0' MIN.

FILL MATERIAL

FILL MATERIAL

NOT STEEPER
THAN 1.5H:1V
STEEL LIGHT
STANDARD
FOUNDATION

NOT STEEPER
THAN 2H:1V

STEEL LIGHT
STANDARD
FOUNDATION

SLOPE 3H:1V
THRU 2H:1V

SLOPE FLATTER
THAN 3H:1V

SECTION VIEW

SECTION VIEW

CASE A

CASEB

SLOPES 3H:1V THRU 2H:1V (MAX.)

SLOPES FLATTER THAN 3H:1V

EMBANKMENTS

PROVIDE 3.0' MIN. LEVEL GRADE


TO PREVENT BUILD-UP OF DEBRIS
AROUND BASE
VARIES WITH

VARIES WITH

OFFSET DISTANCE
(3.0' MIN.)

OFFSET DISTANCE
(3.0' MIN.)

BACK SLOPE

EDGE OF
SHOULDER

EDGE OF
SHOULDER

HAND HOLE

BACK SLOPE

HAND HOLE

SLIP BASE

SLIP BASE
FILL MATERIAL

LEVEL

LEVEL

FILL MATERIAL

FORE SLOPE STEEPER


THAN 4H:1V (2H:1V MAX.)

CULVERT - SEE CONTRACT PLANS


FOR SIZE AND LOCATION
(SEPARATE BID ITEM)

STEEL LIGHT
STANDARD
FOUNDATION

STEEL LIGHT
STANDARD
FOUNDATION

CULVERT- SEE CONTRACT PLANS


FOR SIZE AND LOCATION
(SEPARATE BID ITEM)

SECTION VIEW

SECTION VIEW

CASEC

CASED

FORE SLOPES 4H:1V OR FLATTER

FORE SLOPES STEEPER THAN 4H:1V (2H:1V MAX.)

STEEL LIGHT STANDARD


PLACEMENT (SLIP BASE)
STANDARD PLAN .J-28.22-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

DITCH SECTIONS

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

fJ'I Washington

08-07-07
DATE

State Department of Transportation

NOTES

rn
z

3.0' MIN. FOR BEAM GUARDRAIL


4.0' MIN. FOR CONC. BARRIER TYPE 2

3.0' MIN. FOR BEAM GUARDRAIL


4.0' MIN. FOR CONC. BARRIER TYPE 2

w
w

1. See Standard Plan J-28.30 for foundation details


and construction methods.

0::
ID
....1
....1

iii

1ii
z

EDGE OF SHOULDER/
FACE OF GUARDRAIL

EDGE OF SHOULDER/
FACE OF GUARDRAIL

TRAFFIC BARRIER
(BEAM GUARDRAIL SHOWN)

TRAFFIC BARRIER
(BEAM GUARDRAIL SHOWN)

2. See Standard Plan J-28.50 for pole base and


hand hole details.
HAND HOLE

\HAND HOLE

Cl

FIXED BASE

FIXED BASE

~
~

MAXIMUM EXPOSED CONCRETE EQUALS THE RATIO


OF THE GRADE OF THE EXISTING SLOPE TIMES
THE DIAMETER OF THE FOUNDATION

NOT STEEPER
THAN 2H:1V

EXISTING SLOPE
STEEPER THAN 2H:1V

STEEL LIGHT
STANDARD
FOUNDATION

SPECIALLY DESIGNED STEEL


LIGHT STANDARD FOUNDATION

SECTION VIEW

SECTION VIEW

CASEE

CASEF

SLOPES 2H:1V OR FLATTER


BEHIND TRAFFIC BARRIER

SLOPES STEEPER THAN 2H:1V


BEHIND TRAFFIC BARRIER
(SPECIAL DESIGN FOUNDATION)

EMBANKMENTS

PROVIDE 2.0' MIN. LEVEL GRADE TO


PREVENT BUILD-UP OF DEBRIS
AROUND BASE

OUTSIDE OF DESIGN
CLEAR ZONE
4.0' MIN.

4.0' MIN.
ND HOLE

EDGE OF
SHOULDER

DITCH BOTTOM

PROVIDE 2.0' MIN. LEVEL GRADE TO


PREVENT BUILD-UP OF DEBRIS
AROUND BASE

OUTSIDE OF DESIGN
CLEAR ZONE

TOE OF
BACK SLOPE

ND HOLE
FIXED BASE

FIXED BASE

~
BACK SLOPE STEEPER
THAN 3H:1V (2H:1V MAX.)

BACK SLOPE STEEPER


THAN 3H:1V (2H:1V MAX.)
I

STEEL LIGHT
STANDARD
FOUNDATION

EDGE OF SHOULDER
I FACE OF CURB

FORE SLOPE STEEPER


THAN 4H:1V (2H:1V MAX.)

STEEL LIGHT
STANDARD
FOUNDATION

CEMENT CONCRETE
TRAFFIC CURB

SECTION VIEW

SECTION VIEW

STEEL LIGHT STANDARD


PLACEMENT (FIXED BASE)

CASEG

CASEH

STANDARD PLAN .J-28.24-00

ROADSIDE DITCH WITH


FORE SLOPE STEEPER THAN 4H:1V (2H:1V MAX.)

CUT SECTION WITH


BACK SLOPE STEEPER THAN 3H:1V (2H:1V MAX.)

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill

BACK SLOPES

STATE DESIGN ENGINEER

fJ'I Washington

08-07-07
DATE

State Department of Transportation

NOTES
(/)

VARIES - DEPENDS
ON JURISDICTION
(SEE CONTRACT)

w
w

0:::
al

10.0' MIN .

....1
....1

ffi

SHOULDER

1. See Standard Plan J-28.30 for foundation details


and construction methods.
2. See Standard Plan J-28.50 for pole base and
hand hole details.

EDGE OF SHOULDER
I FACE OF CURB

3.0' MIN.

EDGE OF
TRAVELED WAY

HAND HOLE

Cl

FIXED BASE
NOT STEEPER
THAN 2H:1V

STEEL LIGHT
STANDARD
FOUNDATION

STEEL LIGHT
STANDARD
FOUNDATION

SECTION VIEW

SECTION VIEW

CASE I

CASEJ

POSTED SPEED LIMIT LESS THAN 35 MPH

VARIES WITH
OFFSET DISTANCE
3.0' MIN.

POSTED SPEED LIMIT LESS THAN 35 MPH

3.0'

EDGE OF
SHOULDER

10H:1V SLOPE
OR FLATTER
SLOPE ROUNDING

HAND HOLE
FIXED BASE

~~=~~:~~~~~~~,t;~#t~~~=-:NOT
STEEPER THAN 4H:1V
10H:1V SLOPE

PAVEMENT

io

OR FLATTER

N
FILL MATERIAL

STEEL LIGHT
STANDARD
FOUNDATION

eob
STEEL LIGHT
STANDARD
FOUNDATION

SECTION VIEW

SECTION VIEW

CASEK

CASEL

STEEL LIGHT STANDARD


PLACEMENT
MISCELLANEOUS
STANDARD PLAN .J-28.26-01

ROADWAYS WITH 10H:1V


OR FLATTER SIDE SLOPES

PARKING LOTS

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

12-02-08
DATE

Washington State Department of Transportation

NOTES

GROUNDING CONDUCTOR- NON-INSULATED


#4 AWG STRANDED COPPER - PROVIDE
3'- 0" MIN. SLACK (ROUTE CONDUCTOR
TO LUMINAIRE GROUNDING STUD)

CONDUIT COUPLING - INSTALL


FLUSH WITH TOP OF BARRIER
(DO NOT GLUE PVC STUBOUT)

1. See Standard Plan J-28.40 for Luminaire Pole base mounting details.

36"
EIGHT #7 BARS,
EVENLY SPACED

3" DIAM. GROUT WELL (TYP.)


3/4" CHAMFER (TYP.)

CENTER THE CONDUIT


IN THE FOUNDATION

3. Use Steel Light Standard Foundation Type A on level ground or slopes not exceeding
4H : 1V. Use Type B for slopes steeper than 4H : 1V, but not exceeding 2H : 1V.
Slopes steeper than 2H : 1V shall require a special design.

#7 REINFORCING
STEEL BAR
#4 REINFORCING
STEEL HOOP
ANCHOR BOLT (TYP.)
-SEE TABLE

2. The Strap Templates shall be held in place by nuts, 6" from the top of the foundation
and 3" from the bottom of the anchor bolts. 18 heavy duty hex nuts and 6 round
washers are required for a Slip Base assembly. 18 heavy duty hex nuts and 6 plate
washers are required for a Fixed Base assembly.

CLAMP CONDUCTOR TO STEEL


REINFORCING BAR WITH LISTED
CONNECTOR SUITABLE FOR USE
EMBEDDED IN CONCRETE

1'- 3" DIAM. BOLT


CIRCLE (TYP.)

4. These foundations are designed for a minimum of 2000 PSF (TYPE A) or 1500 PSF
(TYPE B) allowable lateral bearing pressure for the soil. A special foundation shall be
required for soil with allowable lateral bearing pressure lower than 1500 PSF.
5. The Luminaire Pole height shall not exceed 50' (H1).

#4 HOOP (TYP.)

0
SEE FIXED BASE FOR DETAILS NOT SHOWN

HEAVY HEX
NUT (TYP.)SIZE TO MATCH
ANCHOR BOLT
(SEE TABLE)

6. Slip Bases shall not be installed on 50' (H 1) poles with Double Mast Arms, nor on
poles weighing more than 1000 lbs.

TOP VIEW

1" DIAM. CONDUIT- CAP EACH


END - PROVIDE ADDITIONAL CONDUIT FOR COMMUNICATION OR
SIGNAL CABLE WHERE SHOWN
IN THE CONTRACT

FIXED BASE

7. Slip Bases are not required on poles placed outside of the Design Clear Zone, nor on
poles installed behind traffic barrier.

PARTIAL ELEVATION VIEW

SLIP BASE

3/4" CHAMFER (TYP.)

9. Exposed portions of the foundation shall be formed to create a Class 2 surface finish.
All forming shall be removed upon completion of foundation construction.

ROUND WASHER SIZE TO


MATCH ANCHOR BOLT (TYP.)
-SEE TABLE

10. For excavation, concrete placement, and backfill options, see METHOD 1 and
METHOD 2 on Sheet 2 of 2.

1'- 6" MIN. BELOW GROUND


2'- 0" MIN. UNDER PAVEMENT

STRAP TEMPLATE
ASSEMBLY (TYP.)
-SEE DETAIL

11. The Anchor Bolts shall be high-strength steel, manufactured from ASTM A449, with
heavy hex nuts and hardened washers. Galvanize the Anchor Bolts according to
AASHTO M232.
C)C>
z~

(3~

<Ca.

3;cn

EXTEND THE CONDUIT 6" MIN. BEYOND


THE FOUNDATION OR THE CONTROLLED
DENSITY BACKFILL

ANCHOR BOLT (TYP.)


-SEE TABLE

Cn~
ll

CLAMP CONDUCTOR TO STEEL


REINFORCING BAR WITH LISTED
CONNECTOR SUITABLE FOR
USE EMBEDDED IN CONCRETE

HEAVY HEX NUT (TYP.)


-SIZE TO MATCH
ANCHOR BOLT
(SEE TABLE)
( D + 1/16") DIAM.
HOLE (TYP.)
-SEE TABLE

ANCHOR BOLT ASSEMBLY


(SLIP BASE SHOWN)

ANCHOR
LUMINAIRE
HEIGHT
(H1)

MAST
ARM
TYPE

BOLT

TABLE

MAST
ARM
LENGTH

ANCHOR BOLT
DIAMETER

~).. i:5 ,J.

~~gs~~
.U..t!:!ID

(!)

~l!!iil;:!o
ooq;~:SCI)~

~n~~

ww

~OQ~>-

(..)

u:::
u.

~~~~8

SLIP BASE

i!offi

2,:;2::1-j:::

~"(IJJ"(~

~~~H
2 1/2" CLR.

STEEL LIGHT STANDARD


FOUNDATION TYPES A & B

~~+--+---I---+--+ +--------'--

STANDARD PLAN J-28.30-02


FIXED BASE

SINGLE

6' TO 16'

1"

20' TO 50'

DOUBLE

6'T08'

1"

20' T045'

DOUBLE

10' TO 16'

1"

46' TO 50'

DOUBLE

10' TO 16'

1 1/8"

1'- 1" (TYP.)

TOP VIEW

STRAP TEMPLATE ASSEMBLY

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ANCHOR BOLT LAYOUT


SEE SLIP BASE FOR DETAILS NOT SHOWN
ELEVATION VIEW

FIXED BASE

<

~~~~~

1-

non

20' TO 50'

..... 2!

"'i!()~[t
~~~~::)

<Cai

~~

~-fj:::

!i1oirh

0~

a. a.

82!~

~~~-~~

it

II

rr-~-TJ
II

::!"'li:;,"
i1@~~~

J::r:

ti
+-+

#7 (TYP.)

13. See Standard Plans C-8b and C-85.14 for steel light standards on traffic barrier.
,.--.,...-----,

ll

en
en
a. a.
oo
oo

II

CONCRETE CLASS 4000P

1/4" STEEL BAR (TYP.)


- 2" WIDE x 1'- 3" LONG

12. The foundation shall be grounded in accordance with the requirements of


Standard Specification 8-20.3(4).

@)

#4 HOOP (TYP.)

ISOMETRIC VIEW

8. Foundations constructed within Ecology Embankments shall be increased in depth by


the depth of the Ecology Embankment.

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

~ Washington Stale Department of Transportation

NOTE

EDGE OF
SHOULDER

These foundation Construction Methods


are applicable to all Steel Light Standard
Placement Cases. See Standard Plans
J-28.22, J-28.24, and J-28.26.

EDGE OF
SHOULDER

LUMINAIRE POLE

LUMINAIRE POLE

POLE BASE

POLE BASE
SLOPE ROUNDING

SLOPE ROUNDING
EMBANKMENT
WIDENING

EMBANKMENT
WIDENING

cCID

UNDISTURBED SOIL
{TYP.)

SLOPE 2H: 1V {MAX.)


OR FLATTER

ww

cCID

UNDISTURBED SOl
{TYP.)
TEMPORARY SLOPE OR
SHORE AS REQUIRED {TYP.)

ww

D.. D..

~~

SLOPE 2H : 1V {MAX.)
OR FLATTER

LIGHT STANDARD
FOUNDATION

CONCRETE CLASS 4000P

~~

METAL FORM FOR LIGHT


STANDARD FOUNDATION

OVER-EXCAVATED AREA SHALL BE BACKFILLED


WITH CONTROLLED-DENSITY-FILL {CDF), OR WITH
COMPACTED BORROW IN ACCORDANCE WITH
STANDARD SPECIFICATION 8-20.3{2)

CONCRETE CLASS 4000P

LIMITS OF STRUCTURE
EXCAVATION
UNDISTURBED SOIL

3'- 0" DIAM.


UNDISTURBED SOIL

{CASE A SHOWN)

{CASE A SHOWN)

METHOD 1

METHOD 2

NO SUBSURFACE FORM

METAL (SUBSURFACE) FORM REQUIRED

This option is only used when the existing soil in the hole will
remain standing and the cement concrete can be placed without causing the soil to collapse. Concrete shall be cast directly
against undisturbed soil.

When the existing soil will not retain a vertical face, over-excavate
the foundation area and install a 36" diameter, corrugated metal
(pipe) form. The corrugated metal form shall not extend more than
6" below any portion of the foundation that will remain exposed
upon final grading. Continue forming to full height using paper or
cardboard form to achieve a smooth finish on final exposed cement
concrete. Support the form as necessary to remain plumb.

Auger the hole for the foundation. Use paper or cardboard form
to achieve a smooth finish on the final exposed cement concrete.
Support the form as necessary to remain plumb.

See Standard Plans J-28.24 and J-28.26 for maximum heights


of exposed foundation when no embankment widening is to be
installed.

See Standard Plans J-28.24 and J-28.26 for maximum heights


of exposed foundation when no embankment widening is to be
installed.

Place the concrete foundation.


Place the concrete foundation.
After concrete has cured, remove the paper or cardboard
form portion.

After concrete has cured, remove the paper or cardboard


form portion.

Backfill with controlled-density fill or compacted borrow in accordance with Standard Specification 8-20.3(2).

Construct the embankment widening (if required).

Construct the embankment widening (if required).

STEEL LIGHT STANDARD


FOUNDATION TYPES A & B
STANDARD PLAN J-28.30-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

CONSTRUCTION METHODS

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

~ Washington Stale Department of Transportation

0
0

::J

0::

NOTES

HEAVY HEX NUT {TYP.)


SIZE TO MATCH ANCHOR BOLT
SEE TABLE - STD. PLAN J-28.30

....1
....1

ROUND WASHER {TYP.)


~ -SIZE TO MATCH ANCHOR BOLT

LUMINAIRE POLE

11..

HEAVY HEX NUT {TYP.)


SIZE TO MATCH ANCHOR BOLT
SEE TABLE - STD. PLAN J-28.30

POLE BASE PLATE

1. 50' (H1) poles with double mast arms or poles


weighing in excess of 1000 LBS shall not be
installed on a slip base.

{ D+1/16") DIAM. HOLE W/


SMOOTH CHAMFERED
EDGES - SEE TABLE
- STD. PLAN J-28.30

LUMINAIRE POLE

2. Galvanizing shall be in accordance with


AASHTO M 111.

_A

&b

3. See Standard Plans C-8b, C-14h, and J-28.60


for foundation and base plate requirements
when light standards are mounted on cement
concrete traffic barrier.

KEEPER PLATE
ANCHOR/SLIP PLATE ASSEMBLY
- SEE STD. PLAN J-28.42

POLE BASE PLATE

PLATE WASHER (TYP.)


- SEE DETAIL

3/8" DIAM. DRAIN TUBE


IN GROUT PAD

CAPPED CONDUIT
SLIP BASE FOUNDATION
- SEE STD. PLAN J-28.30

3" DIAM. GROUT WELL


{TYP.)

EXPLODED VIEW

_A

~
e

1/2" THICK X 2" WIDE X


2 3/4" LONG STEEL BAR

PLATE WASHER DETAIL

FIXED BASE FOUNDATION


- SEE STD. PLAN J-28.30
3" DIAM. GROUT WELL
{TYP.)

0---

4. See Standard Specification Section 6-03.3(33)


and 8-20.3 (4) for the torque requirements for
all of the Anchor Bolt installations. Install 1-inch
diameter Clamping Bolts in all Slip Bases to
a torque of 95 Foot-Pounds - See Standard
Specification Section 8-20.3 (13)A.
DO NOT OVERTIGHTEN.
After state inspection, burr threads to prevent
nut rotation.
5. For Anchor Bolt Diameter" D ", See Table,
Standard Plan J-28.30.

CAPPED CONDUIT

EXPLODED VIEW

ANCHOR/SLIP PLATE
ASSEMBLY

SLIP BASE FOUNDATION


- SEE STD. PLAN J-28.30
APPLY GROUT EVEN WITH THE BOTTOM
OF THE POLE BASE PLATE AFTER
PLUMBING THE LUMINAIRE POLE

PLAN VIEW
LUMINAIRE POLE

SLIP BASE

POLE BASE PLATE

3/8" I.D. DRAIN TUBE


THE FINAL HEIGHT OF THE ANCHOR BOLTS MUST
BE BELOW THE TOP OF THE ANCHOR/SLIP
PLATE ASSEMBLY TO ENSURE PROPER
FUNCTION OF THE SLIP BASE

TORQUE ANCHOR BOLTS


-SEE NOTE 4

IN GROUT PAD

TOP OF ANCHOR/SLIP
PLATE ASSEMBLY

APPLY GROUT EVEN WITH THE BOTTOM


OF THE ANCHOR PLATE AFTER
PLUMBING THE LIGHT STANDARD

,.--::--....,.......--;-=t~5::::;::Fr"C:~----""""'~4" MAX.
.

ASSEMBLED AND GROUTED

t>

ELEVATION VIEW
t> .
t>"

FIXED BASE

LEAVE:::: 6" HOLLOW IN THE


CENTER OF THE GROUT PAD

SECTION

STEEL LIGHT STANDARD


BASE MOUNTING

{CONDUIT NOT SHOWN)

STANDARD PLAN J-28.40-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
ASSEMBLED
ISOMETRIC VIEW

SLIP BASE

ASSEMBLED
ISOMETRIC VIEW

FIXED BASE

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

NOTES

CLAMPING BOLT TABLE

rn
z

1'/." DIAM. HOLE W/ SMOOTH


CHAMFERED EDGES

w
w

0::
ID

LUMINAIRE POLE

....1
....1

iii

1ii
z

Cl

HEAVY HEX NUT (TYP.)- SIZE


TO MATCH CLAMPING BOLT
1/2" THICK )( 2" WIDE )(
2 3/4" LONG STEEL BAR

LUMINAIRE
HEIGHT
(H1)

MAST
ARM
TYPE

MAST
ARM
LENGTH

CLAMPING BOLT
DIAMETER

1. 50' (H 1) poles with double mast arms or poles weighing in excess of 1000 lbs.
shall not be installed on a Slip Base.

20' TO 50'

SINGLE

6' TO 16'

1"

2. The Slip and Anchor Plates shall be manufactured from ASTM A572 GR.SO or
ASTM A588. All Slip Plate notched surfaces shall be finished smooth.

20' TO 45'

DOUBLE

6' TO 8'

1"

46' TO 50'

DOUBLE

6' TO 8'

20' TO 45'

DOUBLE

10' TO 16'

46' TO 50'

DOUBLE

10' TO 16'

0
0
0

PLATE WASHER DETAIL

PLATE WASHER (TYP.)


-SEE DETAIL

non

SLIP BASE NOT ALLOWED

3. The Clamping Bolts shall be high strength steel, manufactured from AASHTO
M164, with heavy hex nut and hardened washer. Galvanize the Clamping
Bolts according to AASHTO M232.
4.

Round and smooth all edges along wire-way to protect the conductors. See
Standard Plan J-28.70 for wiring details.

5. Galvanize the Anchor/Slip Plate after fabrication according to AASHTO M 111.


6. Clamping Bolt diameters may vary on existing installations. Replace them with
the same size as the originals when repairing or reusing a luminaire pole.

6"

8 1/2"

POLE BASE PLATE

1'- 3" DIAM.


BOLT CIRCLE

'

1" (TYP.)

9/16" R. (TYP.)

120" (TYP.)

9"

8 1/2"

KEEPER PLATE

SLIP PLATE
1 1/16" DIAM.
HOLE (TYP.)

HARDENED ROUND WASHER (TYP.)


-SIZE TO MATCH CLAMPING BOLT

1'- 3" DIAM.


BOLT CIRCLE
35" (TYP.)

6" DIAM. HOLE

7" DIAM. HOLE


6" DIAM.HOLE

(28 GAUGE SHEET METAL)

1 1/4" THICK
ANCHOR PLATE

1'- 3" DIAM.


BOLT CIRCLE

TOP VIEW

120" (TYP.)

KEEPER PLATE

1 1/16" DIAM.
HOLE (TYP.)

120" (TYP.)
TOP VIEW

TOP VIEW

SLIP PLATE

ANCHOR PLATE

ANCHOR/SLIP PLATE ASSEMBLY


60"

~
,

HEAVY HEX CLAMPING BOLT


(TYP.)- 1" DIAM. (SEE NOTE 6).
~ TORQUE CLAMPING BOLTS-

I~

SLIP PLATE

SEE NOTE 4, STD. PLAN J-28.40

SLIP PLATE

--4
ANCHOR PLATE
ANCHOR PLATE

3/8

SECTION
TOP VIEW

EXPLODED
ISOMETRIC VIEW

ANCHOR/SLIP PLATE
ASSEMBLY

STEEL LIGHT STANDARD


ANCHOR/SLIP PLATE
FOR SLIP BASE
STANDARD PLAN .J-28.42-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


- .
------::S=:TA=TE:-=D=ES::=IG'"'"'N
...
E:::-;NG:::::IN::=E=ER,------

fJ'I Washington

08-07-07
DATE

State Department of Transportation

LUMINAIRE POLE
1" HEAVY HEX NUT (TYP.) ~
PLATE WASHER (TYP.) SEE STD. PLAN J-28.42

<3>

1. Galvanize the Elbow Assembly after fabrication according to


AASHTO M 111.

POLE BASE PLATE

2. See Standard Plan J-28.50 for Pole Base and Hand Hole details.

3/16" THICK PREFORMED


"FABREEKA" FABRIC PAD WITH 5"
DIAM. HOLE. CEMENT TO FLANGE
PLATE AND TRIM OUTSIDE EDGE
FLUSH.

I.

1'- 3"

<3>PoLE BASE PLATE

NOTES

1.00 - 8 UNC x 8" LONG BOLT THREADED FULL LENGTH


(ASTM A325 OR F 1554 GR. 105) WITH TWO HEAVY HEX NUTS,
TWO PLATE WASHERS, AND A ROUND WASHER (TYP.)
(GALVANIZED AASHTO M232)

LUMINAIRE POLE

5"

I
, (TYP.)

9"

120" (TYP.)

5" DIAM.
ACCESS HOLE

1 1/4" DIAM.
HOLE (TYP.)

1'- 3" DIAM.


'~BOLT CIRCLE

BAND (TYP.)

.,......
LOCK WASHER
(TYP.)

_,..- 1 5/8" PLATE


(ASTM A36)

10 3/4" O.D. X 0.365 WALL


- WELDED ELBOW
(ASTM A234 GR. WPB)

.,.....

5/16" X 1/2" FLAT


HEAD MACHINE
SCREW (TYP.)

1" DIAM. HEAVY ~


HEX BOLT (TYP.)

0.

3 1/2" X 3/16"
(17" MIN. LONG)
THICK STEEL
BAND (TYP.)
- BEND TO FIT

1/2" DIAM. WEEP

SECTION

VIEW0

SEE CONTRACT PLAN FOR SLOPE


OF PARAPET FACE.

<3> SEE

STANDARD PLAN J-28.50 FOR


POLE BASE PLATE REQUIREMENTS.

TAP FOR BOLT (TYP.)

1 5/8" PLATE
(ASTM A36)

5" DIAM. HOLE

FABREEKA PAD
ELBOW

5/16" X 1/2" FLAT


HEAD MACHINE
SCREW W/ LOCK
WASHER (TYP.)
(STAINLESS STEEL)

THE FACE SHALL BE PLANE AFTER


FABRICATION, TO PROVIDE A SEAL BETWEEN
THE BARRIER AND THE ELBOW.

EXPLODED ISOMETRIC VIEW

STEEL LIGHT STANDARD ELBOW DETAIL


FOR LUMINAIRE POLES WITH SINGLE MAST ARM 12'- 0" OR LESS AND
DOUBLE MAST ARMS 8'- 0" OR LESS, MOUNTED ON BRIDGE OR RETAINING WALLS.
HAND HOLE

LUMINAIRE POLE

HAND HOLE

PEDESTRIAN
RAILING

LUMINAIRE POLE

LUMINAIRE POLE

I(.)(/)

w ;:2z
w I-<(

(/) z

....J

oa.

ELBOW - SEE DETAIL

ELBOW - SEE DETAIL

1" CONDUIT - SEE


BRIDGE PLANS

1" CONDUIT - SEE


BRIDGE PLANS

(..)

ELBOW - SEE DETAIL

1" DIAM. H. S. BOLT W/ HARDENED


LOCK WASHER AND NUT (TYP.)
(ASTM A325 OR F 1554 GR. 105)

_.II>'.

1" CONDUIT - SEE


BRIDGE PLANS
'9.

SEE BRIDGE PLANS FOR


LUMINAIRE ANCHORAGE DETAIL

1" DIAM. H. S. BOLT W/ HARDENED


LOCK WASHER AND NUT (TYP.)
(ASTM A325 OR F 1554 GR. 105)

'II

....

.':.

....
'II.":. . ". ': :" . .,_

: . 1>

1" DIAM. H. S. BOLT W/ HARDENED


LOCK WASHER AND NUT (TYP.)
(ASTM A325 OR F 1554 BR. 105)

'

1>-

I>

I> ~

SEE BRIDGE PLANS FOR LUMINAIRE


ANCHORAGE DETAIL

SEE BRIDGE PLANS FOR LUMINAIRE


ANCHORAGE DETAIL

STEEL LIGHT STANDARD


ELBOW MOUNTING ON
BRIDGE 7 RETAINING WALL
STANDARD PLAN J-28.45-01
SHEET 1 OF 1 SHEET

WHEN TRAFFIC BARRIER HEIGHT IS 42", MAINTAIN APPROX.


HEIGHT FROM TOP OF BARRIER TO HAND HOLE SHOWN.

BRIDGE PEDESTRIAN BARRIER

SINGLE-SLOPE BRIDGE TRAFFIC BARRIER

F-SHAPE BRIDGE TRAFFIC BARRIER

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

TYPICAL SECTIONS

NOTES
1. Pole Base Plate for a Slip Base design shall be 1 1/4" steel manufactured from ASTM A572 GR. 50
or ASTM A588. Pole Base Plate for a Fixed Base design shall be either 1 1/4" steel manufactured
from ASTM A572 GR. 50, ASTM A588, or 1 1/2" manufactured from ASTM A36. All Pole Base
Plate notched surfaces shall be finished smooth.

ROUND AND SMOOTH


INSIDE EDGES

2. Round and smooth all edges along wire-way to protect conductors. See Standard Plan J-28.70 for
wiring details.

POLE BASE PLATE

3. Galvanizing shall be in accordance with AASHTO M 111.


4. See Standard Plans C-8b, C-85.14, and J-28.60 for foundation and base plate requirements when
steel light standards are mounted on concrete traffic barrier.

REMOVABLE RAINTIGHT HAND


HOLE COVER WITH GASKET _ _ _,
- FASTEN WITH TWO STAINLESS
STEEL (ASTM F 593) SCREWS

5. See Standard Plan J-28.42 for details when Slip Base is required.

TYPICAL HAND HOLE ORIENTATION


LUMINAIRE POLE

VIEW0

HAND HOLE

THE CONDUCTOR ATTACHMENT CONFIGURATIONS VARY AMONG DIFFERENT


MANUFACTURERS. CONDUCTOR ATTACHMENTS ARE REQUIRED ON ALL POLES,
FIXED OR SLIP BASE.
T = RIM PLATE THICKNESS BY LUMINAIRE
POLE FABRICATOR.

FIXED BASE: RADIUS = ( D/2+1/16") (TYP.)- FOR


"D," SEE TABLE ON STANDARD PLAN J-28.30

9/16" (TYP.)- MATCH SLIP


SLIP BASE: RADIUS
PLATE, STANDARD PLAN J-28.42
LUMINAIRE POLE

CXl

POLE BASE PLATE

LUMINAIRE POLE

r
1" MIN.

------\___ 1'- 3" DIAM.


BOLT CIRCLE

BASE PLATE

POLE BASE PLATE


FOR DETAILS NOT SHOWN, SEE VIEW

ORIENTATION FOR INSTALLATION ON BRIDGE OR


RETAINING WALL - SEE STANDARD PLAN J-28.45
(COVER NOT SHOWN FOR CLARITY)

VIEW0

ELEVATION VIEW

FOR PLATE THICKNESS, REFER TO NOTE 1

ABOVE

TOP VIEW
1/4" THICK, OR NO THINNER THAN POLE WALL THICKNESS.
TACK WELD OR SEAL WELD TO BASE PLATE.

~t

= SIZE

OF FILLET WELD BY LUMINAIRE POLE FABRICATOR.

SECTION

CONFIGURATION AND LOCATION OF THE HAND HOLE


VARIES AMONG MANUFACTURERS MINIMUM SIZE OPENING SHOWN
6" DIAM. HOLE

POLE BASE PLATE DETAIL

POLE BASE PLATE

STEEL LIGHT STANDARD


POLE BASE AND
HAND HOLE DETAILS
STANDARD PLAN J-28.50-02
1/4" BACK-UP STRIP

SHEET 1 OF 1 SHEET

LUMINAIRE POLE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

VIEW0

.....

ISOMETRIC VIEW

STATE DESIGN ENGINEER

06-02-11
DATE

. . . Washington State Department of Transportation

1'- 0"

NOTES

2 1/2"

1. See Standard Plans C-8b and C-85.14 for foundation and anchor bolt details.
2. Round and smooth all edges around hand hole and along the wire-way to
protect the conductors.

1"

STEEL PLATE 1 3/4"


(ASTM A 572 GR. 50
OR ASTM A 588)

3. See Standard Plan J-28.70 for wiring details.


HAND HOLE

4. Install grout after plumbing the pole.

---$-1---$BACK-UP RING
1

5" DIAM. HOLE


CONDUCTOR ATTACHMENT
BRACKET - 1/4" THICK STEEL,
2" WIDE X 4" LONG

CONTINUOUS BACK-UP
RING - 1/4", OR NO
THINNER THAN POLE
WALL THICKNESS - TACK
WELD TO PLATE

POLE WALL

POLE WALL

POLE BASE PLATE

GROUNDING BOLT
CLAMP - 1/8" THICK STEEL,
2" WIDE X 3" LONG

HAND HOLE

CONDUCTOR ATTACHMENT DETAIL


REMOVABLE RAINTIGHT HAND
HOLE COVER WITH GASKET FASTEN WITH TWO STAINLESS
STEEL (ASTM F 593) SCREWS

CONFIGURATIONS VARY AMONG


DIFFERENT MANUFACTURERS
1 1/4" DIAM. HOLE (TYP.)

VIEW0

T = RIM PLATE THICKNESS BY LUMINAIRE POLE FABRICATOR

~ t = SIZE OF FILLET WELD BY LUMINAIRE POLE FABRICATOR

SECTION

LUMINAIRE POLE

4"

HAND HOLE - CONFIGURATIONS VARY


AMONG DIFFERENT MANUFACTURERS
LUMINAIRE POLE

ANCHOR BOLT (TYP.)


- SEE NOTE 1

HAND HOLE

TOP OF POLE BASE PLATE

POLE BASE PLATE

3/8" DRAIN TUBE

TOP OF
FOUNDATION I BARRIER

STEEL LIGHT STANDARD


BARRIER MOUNTED BASE
STANDARD PLAN J-28.60-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

SEE NOTE 4

PLACEMENT DETAIL

ISOMETRIC VIEW

.....

STATE DESIGN ENGINEER

06-02-11
DATE

. . . Washington State Department of Transportation

LUMINAIRE HEAD

---..r------;~ ,---------~

-~: ~:.~:: .:::::U~~N~~::HER

\_ AND CONNECTOR TO SECURE CONDUCTORS AT END OF MAST ARM (TYP.)

INSULATING
GROUNDING
BUSHING

CONDUCTOR WIRES

CONDUCTOR WIRES

END BELL BUSHING

5
HAND HOLE

REMOVE ALL SLACK


BEFORE INSTALLING
CABLE TIE

REMOVE ALL SLACK


BEFORE INSTALLING
CABLE TIE

POLE AND BRACKET


CABLE - TO LUMINAIRE
HEADS

POLE AND BRACKET CABLE


- TO LUMINAIRE HEAD

CONDUCTOR
ATTACHMENT
BRACKET

HAND HOLE

GROUNDING NUT

GROUNDING NUT
SINGLE QUICK
DISCONNECTS

DETAIL"A"

DETAIL "B"

GRSCONDUIT

PVC CONDUIT
SEE DETAIL " A" OR " B"
PER CONDUIT TYPE

0 CABLE
TIE- 120 POUND TENSILE
STRENGTH, BLACK
4> APPLICATION
FOR FIXED BASE SIMILAR,
EXCEPT NO CABLE TIE IS REQUIRED AT

SPLICE
(TYP.)

<]

BONDING JUMPER WIRE FOR GRS STEEL

<5)

EQUIPMENT GROUNDING CONDUCTOR

<I

'\

'\

~-__ SEE

DETAIL " C" OR " D"


----PER CONDUIT TYPE

~~::~~---------__ _

\ .....

24" SLACK REQUIRED TO ALLOW QUICK


DISCONNECTS TO BE PULLED OUTSIDE
HAND HOLE 6" MIN.

CONDUITGRS OR PVC

I>

'
''
''
\.' ... _..,/

/)."

JUNCTION BOX

<I.

. I>

LUMINAIRE POLE

BASE WIRING DETAIL


FOR SINGLE MAST ARM

BASE WIRING DETAIL


FOR DOUBLE MAST ARMS

(SLIP BASE SHOWN)

(SLIP BASE SHOWN)

TO GROUNDING NUT

TO GROUNDING NUT
CONDUCTOR
WIRES

GROUNDING CONDUCTOR - FROM


FOUNDATION
DOUBLE QUICK DISCONNECTS - PULL
DOWN TIGHT TO CONDUIT (SHOWN
LEFT UP FOR CLARITY)

............

5' MIN. (PREFERRED)


10' MAX.

/).

GRAVEL PAD

JUNCTION BOX WIRING DETAIL


FOR GROUNDING REQUIREMENTS, SEE

.I

]]

.
. .

STANDARD PLAN J-60.05

POLE AND BRACKET CABLE

'

TRAVELED WAY

'I'

SHOULDER

'I

DETAIL "C"

DETAIL "D"

GRSCONDUIT

PVC CONDUIT

LIGHT STANDARD BASE


(SLIP BASE SHOWN)

~-----------~ ~--~~~~~~~~~~~~~~~~~-~~~~~~~~~~IFINISHEDGROUNDLINE

{_

__:-

STEEL LIGHT STANDARD


WIRING DETAILS

/)."

/)..

NOTE
See Standard Specification 8-20.

JUNCTION BOX

STANDARD PLAN J-28.70-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

CONCRETE FOUNDATION

TYPICAL LOCATION OF JUNCTION BOX AND FOUNDATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

NOTES
(4) 1 1/4" DIAM. ANCHOR BOLTS W/
6- HEAVY HEX NUTS AND
6 - WASHERS PER BOLT BOLT IS GALVANIZED,
FULL LENGTH (ASTM A449
OR F1554 GRADE 105)

1. These Foundations are designed for a minimum of 1,500 PSF allowable lateral bearing pressure for the soil. A Special
Foundation shall be required for soil with allowable lateral bearing pressure lower than 1,500 PSF.

0
0::

ANCHOR BOLT
TEMPLATE

u.

1J

2. These Foundations are designed for installation on level ground, or on sloping ground, not to exceed 2 : 1 slopes. Slopes
steeper than 2 : 1 require a special design.

ANCHOR BOLT TEMPLATE


- 1/2" PLATE, ASTM A36.
GALV. NOT REQUIRED
{2 PER POLE)

3. Foundations constructed within ecology embankments shall be increased in depth, by the depth of the ecology embankment.
4. Foundations not within the parameters of this standard require Special Design. Contact the WSDOT Bridge and Structures
Office through the Engineer for Special Foundation Designs.

;,;
::::i

25 1/2" DIAM.
BOLT CIRCLE

1 3/8" HOLE
{TYP.)

ANCHOR BOLT ASSEMBLY

* THREADED

LENGTH

CAMERA POLE
DRILL AND TAP FOR 1/4" DIAM. CAP SCREW,
3 PLACES, @ 9" CENTER TO CENTER, ALL 4 EDGES
S. S. SCREW, ASTM F593 AND WASHER

ANCHOR BOLT
TOP OF BASE
TOP OF
FOUNDATION

GALVANIZED WELDED WIRE


MESH- SEE NOTE 6

CAMERA
POLE
HEIGHT

DEPTH OF
FOUNDATION

FOR LOAD
CASES
#1 and #2

3H: 1V
OR
2H: 1V
FLATTER

non

5. The top 2' - 0" of the foundation shall use a smooth form (such as paper or cardboard). After the concrete has cured, this
entire form shall be removed.
6. Galvanized Welded Wire Mesh shall be 2 mesh per lineal inch, 0.0625" diam. wire, with 0.4375" overlap. Contractor to form
fit and install.
DESIGN CRITERIA:
This structure has been designed according to the Fifth Edition 2009 AASHTO
Standard Specifications for Structural Supports for Highway Signs, Luminaires,
and Traffic Signals. Basic wind velocity is 90 MPH. Design Life/Recurrence
Interval 50 years and Fatigue Category Ill.

ANCHOR BOLT
ASTM A449 OR F1554 GR 105
DIAMETER

LENGTH

BOLT
CIRCLE

20'- 30'

4'- 6"

6'- 6"

1 1/4"

4' -4"

25 1/2"

40'

5'- 6"

7'- 6"

1 1/4"

4' -4"

25 1/2"

50'

7'- 0"

9'- 0"

1 1/4"

4' -4"

25 1/2"

WIND VELOCITY:
90 MPH
Maximum Pole Deflection shall not exceed 0.7" in 30 MPH and 1.4" in 70 MPH wind.
LOADCASE#1
Camera (1)- EPA= 4.00 sq. ft. @ 2'- 0" above pole top, and:

GROUNDING CONDUCTOR# 4 AWG


STRANDED COPPER WITH 3' MIN.
SLACK, CLAMP CONDUCTOR TO
REBAR WITH LISTED CONDUCTOR
SUITABLE FOR USE EMBEDDED IN
CONCRETE, ROUTE CONDUCTOR TO
CAMERA POLE GROUNDING STUD.

GROUNDING CONDUCTOR# 4 AWG


STRANDED COPPER WITH 3' MIN.
SLACK, CLAMP CONDUCTOR TO
REBAR WITH LISTED CONDUCTOR
SUITABLE FOR USE EMBEDDED IN
CONCRETE, ROUTE CONDUCTOR TO
CAMERA POLE GROUNDING STUD.

GALVANIZED WELDED
WIRE MESH

Dish (1)- 1'- 0" diameter@ pole top level.


LOADCASE#2
Camera (1)- EPA= 4.00 sq. ft. @ 2'- 0" above pole top, and:
Camera (2)- EPA= 0.54 sq. ft. each @ 1' - 0" and 2' - 0" from pole top, and:

CAMERA POLE

NEMA Cabinet (2)- EPA= 1.33 sq. ft. each @ 3' - 8" from pole top, install both NEMA
cabinets back to back, and:

CAMERA POLE

=
.....

2" DIAM. CONDUIT WITH


CAPS ON BOTH ENDS

=
.....

2" DIAM. CONDUIT WITH


CAPS ON BOTH ENDS

Radio Equipment (2)- EPA= 2.25 sq ft. each@ 2'- 0" and 9'- 0" from pole top.

GALVANIZED WELDED WIRE MESHSEE DETAIL

EPA= Effective Projected Area


ALTERNATE #2- CONSTRUCTION METHOD

CD

p
J:
1--

c..

Shoring or Extra Excavation as Required. Excavated area


shall be backfilled with Controlled-Density Fill or with soil in
accordance with Standard Specification 8-20.3(2).

8 -#7 BARS
- EVENLY SPACED

::::l

u.
0::

0
2" CLR. {TYP.)

u.
w

8 -#7 BARS
- EVENLY SPACED

UNDISTURBED
SOIL {TYP.)

....1

[I]

#4 HOOPS@ 1'- 0"


ON CENTER (TYP.)

~
w
w

CAMERA POLE
FOUNDATION DETAILS

LIMITS OF
STRUCTURE
EXCAVATION

en
CONCRETE
CLASS 4000 P

I.

3' - 6" ROUND

.I

#4 HOOPS@ 1'- 0"


ON CENTER (TYP.)
CONCRETE
CLASS4000 P

3'- 6" ROUND

STANDARD PLAN -1-29.10-00


SHEET 1 OF 1 SHEET

UNDISTURBED SOIL

APPROVED FOR PUBLICATION

{TYP.)

FOUNDATION REINFORCEMENT DETAIL

FOUNDATION REINFORCEMENT AND BACKFILL DETAIL

{CONCRETE CAST DIRECTLY AGAINST UNDISTURBED EARTH)

{CONCRETE CAST INSIDE CORRUGATED METAL PIPE STAY-IN-PLACE FORM)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

ALTERNATE # 1

ALTERNATE # 2

1/4" CLOSED CELL


NEOPRENE GASKET

CAMERA MOUNT PLATE

l_

~r

\__

NOTES
SEE POLE TOP DETAIL AND
CAMERA POLE DATA TABLE

POLE TOP PLATE

1. Verify Pole Top Plate, Camera Mount Plate, Bolt Circle, and Bolt
Holes are adequate for the required Camera prior to releasing
poles for manufacturing.

1/4" CLOSED CELL


NEOPRENE GASKET

2. Steel shall be galvanized after fabrication per AASHTO M111.


Hardware shall be galvanized per AASHTO M232. Fasteners less
than 0.50" (in.) diameter shall be stainless or brass.

RAIN CAP DETAIL


13.00" DIAM. POLE
TOP PLATE

4.75" DIAM. BOLT CIRCLE FOR


CAMERA MOUNT WITH 4
0.44" X 0.75" SLOTS EQUALLy
SPACED -SEE NOTES 1 AND 3

1.75" DIAM. CENTER HOLE


(IN BOTH PLATES)

CAMERA MOUNT PLATE


(DIAM.)- SEE NOTE 1

3. Attach Camera to Camera Mount Plate using four (4) 3/8"-16 UNC
x 1. 75" stainless steel bolts with eight (8) stainless steel washers
and four (4) lock-nuts with nylon inserts, or as approved by the
Camera Supplier.

0.50" DIAM. J-HOOK


FOR WIRING WELDED
TO INTERIOR OF POLE
1'- 0" FROM TOP OF
POLE AND 180 FROM
UPPER HANDHOLE

UPPER HAND HOLE


WITH FRAME AND
COVER ON FACE

4. For Ground Mount Details, see Standard Plan J-29.1 0.


For Elbow Mount Details, see Standard Plan J-29.16.

TOP DIAM. "PT"


-SEE TABLE

DESIGN CRITERIA:
J-HOOK FOR WIRING
LOAD CASE#1

VIEW0

2 1/2" DIAM. HEAVY WALLED


PIPE T=0.276"

This structure has been designed according to the Fifth Edition


2009 AASHTO Standard Specifications for Structural Supports
for Highway Signs, Luminaires, and Traffic Signals. Basic wind
velocity is 90 MPH. Design Life/Recurrence Interval 50 years.
WIND VELOCITY:

CAMERA MOUNT PLATE

90MPH
Maximum Pole Deflection shall not exceed 0. 7" in 30 MPH and
1.4" in 70 MPH wind.

POLE TOP
PLATE

LOAD CASE #1:

.~

0.75" X 1" SLOT


(2 REQUIRED) 180 APART
TO FACILITATE GALVANIZING
-ORIENTED AS REQUIRED

Camera (1) - EPA= 4.00 sq. ft. @ 2' - 0" above pole top, and:

1/4-20 NC, HHCS S. S. (TYP.)


LENGTH SUFFICIENT TO
SECURE CONDUCTOR BUT
NOT TOUCH POLE WALL

~Cl

w
f-..l

:cO

Dish (1) - 1' - 0" diameter@ pole top level.


LOAD CASE #2:

(.!)0.

Camera (1) - EPA= 4.00 sq. ft. @ 2' - 0" above pole top, and:

iii~

UPPER HAND HOLE


5.625" X 7.375"
FRAME WITH COVER

::cw
~:2

Camera (2)- EPA= 0.54 sq. ft.@ 1'- 0" and 2'- 0" from pole top, and:

w(
:2w
(w
(J)

POLE TOP DETAIL

NEMA Cabinet (2) - EPA= 1.33 sq. ft. @ 3' - 8" from pole top, install
back-to-back NEMA Cabinets, and:
POLE
WALL

ROUND OR
MULTI-SIDED

BOLT HOLE, DIAM. "Z"


-SEE TABLE

Radio Equipment (2)- EPA= 2.25 sq. ft. each@ 2'- 0" and 9'- 0"
from pole top.

CONDUCTOR

ANCHOR BOLT
CIRCLE-SEE
TABLE FOR DIAM.

EPA= Effective Projected


Area

STEEL PLATE
1/4" STEEL CHANNEL

GROUND ANGLE
1/2"- 13 NC TAPPED

CONDUCTOR ATTACHMENT DETAIL

CONDUCTOR
ATTACHMENT
-SEE DETAIL

CONDUCTOR ATTACHMENT DETAILS


MAY VARY PER MANUFACTURER

VIEW0
LOWER HAND HOLE
SHALL BE PLACED
goo TO ROADWAY
GROUND ANGLE

LOWER HAND HOLE


5.625" X 7.375"
FRAME WITH COVER
TOP OF FOUNDATION OR
TOP OF MOUNT (SEE
CONTRACT FOR TYPE
REQUIRED- SEE STANDARD
PLAN J-29.10 OR J-29.16
FOR DETAILS)

GALVANIZED WELDED
WIRE MESH- SEE
STANDARD PLAN J-29.10

CAMERA POLE
CAMERA POLE FOR LOADING
LOAD CASE#1
POLE BASE DETAIL

(TOP MOUNT CAMERA AND 1'- 0" DIAM. DISH)

CAMERA POLE DATA


POLE TUBE

CAMERA
HEIGHT
"PL"
(FT.)

POLE
MOUNT
TYPE

TOPDIAM.
''PT''
(IN.)
(MIN.)

SQUARE

HOLE

(IN.)

BOLT
CIRCLE
(IN.)

ugn

nz

(IN.)

ANCHOR CONNECTION
BOLT
BOLT
DIAM.
DIAM.
(IN.)
(IN.)

CAMERA POLE
STANDARD

15

ELBOW

8.50

25.00

25.50

1.50

1.25

20

ELBOW

8.50

25.00

25.50

1.50

1.25

STANDARD PLAN -1-29.15-00

30

ELBOW

9.00

25.00

25.50

1.50

1.25

SHEET 1 OF 2 SHEETS

20-30

GROUND

9.00

25.00

25.50

1.50

1.25

40

ELBOW

9.00

25.00

25.50

1.50

1.25

40

GROUND

9.00

25.00

25.50

1.50

1.25

1.25

50

ELBOW

10.00

25.00

25.50

1.50

50

GROUND

10.00

25.00

25.50

1.50

1.25

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

06-27-11
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

. . . Washington State

J-HOOK

SEE POLE TOP DETAIL AND


CAMERA POLE DATA TABLE

180

RADIO EQUIPMENT
REINFORCING PLATE

NEMA 4X TERMINAL
CABINET (STAINLESS STEEL
WITH HINGED DOOR)

GROUNDING NUT/ANGLE

c.,

2" COUPLINGS

'

HAND HOLE

HAND HOLE (3' FROM TOP)

(1' FROM TOP)

RADIO ATTACHMENT HOLE

goo--

-'t--

RADIO EQUIPMENT
REINFORCING PLATE
(TYP.)- SEE DETAIL

'

~~

~~

<fSo

~ov~~ o~
~ q"..J' n.__<Q

0~
<Q~0

24 LUG TERMINAL STRIP


WITH 6 JUMPERS

NEMABOX
ATTACHMENT
-SEE DETAIL

--ct--- 270

UPPER HAND HOLE


WITH FRAME AND
COVER ON FACE

GROUNDED RECEPTACLE
- GFCI 20 AMP-125 VOLT

b
'

GROUNDING BUSS

oo

O'

0~~

SEAL WITH SILICONE


(TYP.)

NEMA BOX DETAIL

LOWER HAND HOLE

~Ov

J-HOOK (1' FROM TOP)

~POLE TOP PLATE

RADIAL INDEX
LOADCASE#2

@(TYP.)
;:::
'

'

ji

12

. .,. o_. .,. 25~Tb)


~

0.50" DIAM. J-HOOK


FOR WIRING WELDED
TO INTERIOR OF POLE
3' - 0" FROM TOP OF
POLE AND 180 FROM
UPPER HANDHOLE

b
'

It)

J-HOOK FOR WIRING


LOADCASE#2

13

1/4" DIAM. DRAIN HOLE


- DRILL FROM INSIDE

NEMABOX
ATTACHMENT DETAIL

3/8" THICK
REINFORCING
PLATE TO INSTALL
RADIO EQUIPMENT

KEY

CD

CAMERA UPPER HANDHOLE

CONDUIT

@)
@

END BUSHING

PLATE CENTERED
OVER 2.50" DIAM.
HOLE IN POLE WALL

CAMERA MOUNT PLATE

(1)
@
@
(j)
@

@
@

0.19

CAMERAITDA POLE MOUNTS

(]) NEMA 4X (STAINLESS STEEL)


- SIZE 16" H X 12" w X 6" D

CD

POLE

LOWER HAND HOLE


SHALL BE PLACED
goo TO ROADWAY

2" COUPLING
2" SHORT NIPPLE

RADIO EQUIPMENT
REINFORCING PLATE

CHANNEL DRILLED 1/8" OVERSIZE OF NIPPLE

CAMERA POLE
STANDARD

STEEL WASHER
WATERTIGHT LOCKNUT

BACK PLATE - DRILL OVER SIZE FOR CONDUIT,


SEAL WASHER, AND LOCKNUT

TERMINAL BLOCK
HINGED DOOR WITH TWO PAD-LOCKABLE
FLIP LATCHES (TYP.)
J-HOOK FOR WIRING

CAMERA POLE FOR LOADING


LOADCASE#2
(TOP MOUNT CAMERA, 2 SIDEMOUNT CAMERAS,
2 NEMA CABINETS & 2 RADIO EQUIPMENTS)

TOP OF FOUNDATION OR
TOP OF MOUNT (SEE
CONTRACT FOR TYPE
REQUIRED - SEE STANDARD
PLAN J-29.10 OR J-29.16
FOR DETAILS)

STANDARD PLAN -1-29.15-00


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

06-27-11
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

. . . Washington State

rn
z

NOTES

w
w
m
0::

1. For information not shown, see Steel Light Standard Elbow detail, Standard Plan J-28.45 .
For Camera Pole Details, see Standard Plan J-29.15.

....1
....1

iii

25"

2. Round and smooth all edges along wire-way to protect conductors.

0.25"R.
(TYP.)

3. The manufacturer shall verify that the Elbow Top Plate matches the Camera Pole Base, and shall
submit the shop drawings for approval.

4. Galvanize after fabrication according to AASHTO M111.


1 5/8" ELBOW TOP
PLATE (A36)

5. Install galvanized steel protective band (3/16" thick x 3 1/2" high (A36)) on all four sides after truing
pole, as shown in Standard Plan J-28.45, except fasten 6" from corners on 25" square base.

25.50" DIAM.
BOLT CIRCLE
5"DIAM.
HAND HOLE

VIEW0

TAP FOR 1 1/4" DIAM. BOLT FOR 1 1/4"- 8 UNC, 8" LONG BOLT
THREADED FULL LENGTH (ASTM A325) WITH TWO HEAVY HEX
NUTS AND 3 ROUND WASHERS (TYP.)
(ASTM A325 or F1554 GR. 105)

1'- 3"
1.25" DIAM. HOLE (TYP.)
- FOR 1" DIAM. ANCHOR BOLT
ASSEMBLY TO BARRIER OR WALL
(ASTM A325 or F1554 GR. 105)

10 3/4" O.D. X 0.365 WALL


-WELDING ELBOW
(ASTM A234 GR.WPB)

1 5/8" PLATE (A36)

1/2" DIAM.
WEEP HOLE

VIEW0

ELEVATION VIEW

/.0.. SEE CONTRACT PLANS FOR


~ SLOPE OF PARAPET FACE

CAMERA POLE ELBOW MOUNT- 25" SQUARE

CAMERA POLE
STANDARD DETAILS
STANDARD PLAN J-29.16-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

6120113
DATE

~ Washington State Department of Transportation

TAPER DIVIDER ENDS


TO MATCH INSIDE

NOTES
~

TAPER OF BOX

--

~--mlllllllll---

"""-

5/16" X 1" S. S.
COUPLING NUT \
(TYP.)

------lllllllllll-~

JUNCTION BOX DIMENSION TABLE

--

1. All box dimensions are approximate. Exact configurations vary among manufacturers.

BOX INTERIOR LENGTH- 1/16"


(TYP.)>-1-,---,-/4-,-------,~

--~--mlllllllll---

b
.....

5/16" X 1 1/2" S. S.
SET SCREW (TYPL~---{;;; __

L..----------------..J
DIVIDER PLATE

SIDE VIEW

.I

.I

2. Minimum lid thickness shown. The diamond pattern shall be a minimum of 28% of the overall
thickness. Junction Boxes installed in sidewalks, walkways, and shared-use paths shall have
a slip-resistant coating on the lid and lip cover plate, and shall be installed with the surface flush
with and matched to the grade of the sidewalk, walkway, or shared-use path. The non-slip
lid shall be identified with permanent markings on the underside, indicating the type of surface
treatment (see Contract Documents for details) and the year of manufacture. The permanent
marking shall be 1/8" inch line thickness formed with a stainless steel weld bead and shall be
placed prior to hot-dip galvanizing.

TYPE1

TYPE2

OUTSIDE LENGTH OF JUNCTION BOX

22"

33"

OUTSIDE WIDTH OF JUNCTION BOX

17"

22 1/2"

INSIDE LENGTH OF JUNCTION BOX

18"- 19"

28" -29"

13"- 14"

17"- 18"

E LID LENGTH

17 5/8"

28 5/8"

3. Lid support members shall be 3/16" minimum thick steel C, L, or T shape, welded to the frame.

12 5/8"

18 1/8"

6"

12"

4. A 1/4-20 NC x 3/4" stainless steel ground stud shall be welded to the bottom of the lid; include
(2) stainless steel nuts and (2) stainless steel flat washers.

D INSIDE WIDTH OF JUNCTION BOX

BOX TYPE
ITEM

:E
10 GAGE
GALVANIZED
STEEL

ELEVATION VIEW
(FOR TYPE 2 JUNCTION BOX ONLY)

LID SUPPORT (TYP.)


-SEE NOTE3

a::
c(

LID WIDTH
CAPACITY- CONDUIT DIAMETER

5. Bolts and nuts shall be liberally coated with anti-seize compound.

3/16" (TYP.)
DIAMOND PATTERN
-SEE NOTE2

GROUND STUD
-SEE NOTE4

LID SUPPORT (TYP.)

COUPLING NUT
FOR ALTERNATIVE 2
-SEE SHEET2

6. Equipment Bonding Jumper shall be # 8 AWG min. x 4' of tinned braided copper.

3/8" STEEL COVER


LIP PLATE (TYP.)

WELDED WIRE
REINFORCEMENT
(TYP.)

7. The System Identification letters shall be 1/8" line thickness formed by engraving, stamping, or with a
S. S. weld bead. See Cover Marking detail. Grind off diamond pattern before forming letters. For
System Identification details, see Standard Specification 9-29.2(4).
8. When required in the Contract, provide a 10" x 27 1/2", 10 gage divider plate, complete, with fasteners,
in each Type 2 Junction Box where specified.

LID LIFTING NOTCH


- 1/4" X 3/4"

9. When required in Contract, provide a 12" deep extension for each Type 2 Junction Box where specified.
10. See the Standard Specifications for alternative reinforcement and class of concrete.
11. Headed Anchor Shear Studs must be welded to the Steel Cover Lip Plate and wire tied in two places to
the vertical Welded Reinforcement Wire when in contact with each other. Wire tie all other Headed
Anchor Shear Studs to the horizontal Welded Reinforcement Wire.

HEADED ANCHOR SHEAR


STUD- 3/8" x 3" 10 COUNT
STUDS EVENLY SPACED
AROUND FRAME (PLACE
TO SIDE OF LID BOLT
DOWN SUPPORT ANGLE
WHEN USING LOCKING
DETAIL ALTERNATIVE 2),
-SEE NOTE 11

12. Lid Bolt Down Attachment Tab provides a method of retrofitting by using a mechanical process in lieu of
welding. Attachment Tab shown depicts a typical component arrangement; actual configurations of
assembly will vary among manufacturers. See approved manufacturers' shop drawings for specifics.
HEADED ANCHOR
SHEAR STUD (TYP.)
-SEE NOTE 11

1 3/8" DIAM. HOLE WITH


1/2- 13 x 1 1/2 STAINLESS
STEEL PENTA HEAD BOLT

3/4
3/4
TOP OF SOIL
SURFACE OR
FINISHED
GRADE

WELDED WIRE HOOP (TYP.)


-SEE NOTE 10

4"
(TYP.)

BOLT PLATE- SEE DETAIL

13. Unless otherwise noted in the plans or approved by the Engineer, Junction Boxes, Cable Vaults, and
Pull Boxes shall not be placed within the sidewalks, walkways, shared use paths, traveled ways or paved
shoulders. All Junction Boxes, Cable Vaults, and Pull Boxes placed within the traveled way or paved
shoulders shall be Heavy-Duty.

LOCKING LID STANDARD


DUTY JUNCTION BOX

SECTION

(CONDUITS NOT SHOWN)

WWR WIRE TIED TO


HEADED ANCHOR
SHEAR STUD (TYP.)

14. Distance between the top of the conduit and the bottom of the Junction Box lid shall be 6" min. to 8" max.
for final grade of new construction only. See Standard Specification 8-20.3(5). Where adjustments
are to be made to existing Junction Boxes, or for interim construction stages during the contract, the
limits shall be from 6" min. to 10" max. See Standard Specification 8-20.3(6).

PERSPECTIVE VIEW

GROUND STUD - SEE NOTE 4

GROUNDING STUD
- SEE NOTE 4

COUPLING NUT FOR ALTERNATIVE 2


-SEE DETAIL "E" ALTERNATIVE 2

1.1 1/2 MIN.

LID SUPPORT (TYP.)


- L SHAPE SHOWN
(SEE NOTE 3)

3/8" STEEL
COVER PLATE

3/8" x 3" HEADED ANCHOR


SHEAR STUD (TYP.)

b
'

$:W
00

..J~

WELDED WIRE
REINFORCEMENT (TYP.)
0/'I'NR) 4x4-W2.9xW2.9
(6 GAGE)- SEE NOTE 10

ww

:CCI)

I-<(

s:m

0~

WCJ

iils:
mo

mo

::!:w
::::l::c
:!:(f)

::!:<C
:::JO
:!:a::
-u.
~0
:!:a.
= 0
~I-

zz
~u:::

= w
"<t::c
"~I-

COVER MARKING DETAIL

r- : :

:::: 1" (TYP.)

1" (TYP.)

ITS_[
1t2" (TYP.>.I

LOCKING LID STANDARD


DUTY JUNCTION BOX
TYPES 1 & 2
STANDARD PLAN J-40.10-03

~f

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

~ GRS CONDUIT

SECTION

WELDED WIRE HOOP


(TYP.) W2.9 (6 GAGE)
-SEE NOTE 10

SECTION

(CONDUITS NOT SHOWN)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

12- 13 x 1 1/2 S. S. PENTA HEAD


BOLT AND 12" S. S. FLAT WASHER

LID LIFTING NOTCH - 1/4" x 3/4"


3/8" STEEL COVER PLATESHOWN CUT AWAY FOR CLARITY

1 3/8" DIAM. HOLE


BOLT PLATE CHANNEL
-SEE DETAIL

2 1/2"

-~

LID SUPPORT- L SHAPE SHOWN


(SEE NOTE 3)

3/8" STEEL COVER


LIP PLATE

~l_l ~

3/8" STEEL COVER


LIP PLATE

to::p~

5/8" X 1"
HORIZONTAL
SLOT

1 1/2
LID SUPPORT
- L SHAPE SHOWN
(SEE NOTE 3)
HEX COUPLING NUT
1 5/8" SLOTTED S. S. CHANNEL
WITH S. S. CHANNEL NUT
AND SPRING

DETAIL

LID BOLT DOWN


ATTACHMENT TAB
-SEE DETAIL

LID HOOK1" X 1" X 3/16" ANGLE

5/8" X 1"
HORIZONTAL SLOT

LID SUPPORT L SHAPE SHOWN


(SEE NOTE 3)

WWR- WELDED
TO LIP PLATE
WELDED WIRE
HOOP (TYP.)
W2.9 (6 GAGE)
-SEE NOTE 10

SECTION

ALTERNATIVE 1 SHOWN
PERSPECTIVE VIEW

SLOTTED STEEL CHANNEL

3/16

WWR- TIED IN 2 PLACES


TO EACH HEADED
ANCHOR SHEAR STUD
WWR 4x4-W2.9xW2.9 (TYP.)
(6 GAGE) - SEE NOTE 10

LID BOLT DOWN ATTACHMENT


TAB- SEE DETAIL

3/8" x 3" HEADED ANCHOR


SHEAR STUD - WELDED TO
LIP PLATE

LID SUPPORTL SHAPE SHOWN


(SEE NOTE 3)

HEX COUPLING NUT


S. S. 5/16 NC X 7/8" WITH
s. s. 5/16 NC X 3/4" BOLT
& (3 EACH) S. S. 5/16"
FLAT WASHERS

DETAIL

ALTERNATIVE 1
LID BOLT DOWN ATTACHMENT TAB

ALTERNATIVE 1 SHOWN
1/2- 13 x 1 1/2 S. S. PENTA HEAD
BOLT AND 1/2" S. S. FLAT WASHER

3/8" STEEL COVER LIP PLATE

1/2-13 x 1 1/2 S. S. PENTA HEAD


BOLT AND 1/2" S. S. FLAT WASHER

(SEE NOTE 12)

1 3/8" DIAM. HOLE

9/16" DIAM.
HOLE

LID LIFTING NOTCH - 1/4" x 3/4"


BOLT PLATE CHANNEL
-SEE DETAIL

2"
1 1/2"

3/8" STEEL COVER PLATESHOWN CUT AWAY FOR CLARITY

3/16
3/16
WWR- TIED IN 2
PLACES TO HEADED
ANCHOR SHEAR STUD

LID BOLT DOWN SUPPORT


ANGLE- 1 1/2" X 3" X 1/4" ANGLE

DETAIL

3/8" STEEL COVER LIP PLATE

3/4" SLOT

BOLT PLATE CHANNEL


1/2" S. S. HEX NUT

.)
1 1/2
3/16
1/8"

LID SUPPORTL SHAPE SHOWN


(SEE NOTE 3)

3/4" ANGLE
(TYP.)

1/4" STEEL PLATE

ALTERNATIVE 3 SHOWN

DETAIL

ALTERNATIVE 3 SHOWN
PERSPECTIVE VIEW

1/8"

1/4" STEEL PLATE

~ [
----0T-

4"

f===3/=4"=RA=DI=US==j

1/4" STEEL PLATE

T"'"

~1

1/8" x 3/4" STEEL ANGLE


- RIGHT ANGLE SHOWN,
MIRROR IMAGE FOR
LEFT ANGLE

3/4" STEEL

LANGLE

--r- Il::::=====::::lI

ft

1/4" S. S. PLATE
LID SUPPORT- L SHAPE SHOWN
(SEE NOTE 3)

(SEE NOTE 12)

1/2- 13 x 1 1/2 S. S. PENTA HEAD BOLT


AND 1/2" S. S. FLAT WASHER
3/8" STEEL COVER
PLATE- SHOWN CUT
AWAY FOR CLARITY

DETAIL

ALTERNATIVE 2
LID BOLT DOWN ATTACHMENT TAB

1/2- 13 x 1 1/2 S. S. PENTA


HEAD BOLT AND 1/2" S. S.
FLAT WASHER

1 1/8" X 2"
VERTICAL SLOT

WWR 4x4-W2.9xW2.9
(TYP.) (6 GAGE)
-SEE NOTE 10

7/16"

LID BOLT DOWN SUPPORT


ANGLE- 2" X 2" X 1/4" ANGLE

2" X 3" X 1/4"


ANGLE

1/2" S. S. HEX NUT

ALTERNATIVE 2 SHOWN
PERSPECTIVE VIEW

ALTERNATIVE 2 SHOWN

WWR- TIED IN 2
PLACES TO HEADED
ANCHOR SHEAR STUD

9/16" DIAM.
HOLE

EXPOSE LID BOLT DOWN


SUPPORT ANGLE TO ATTACH
ALTERNATIVE 2 LID BOLT DOWN
ANGLE ATTACHMENT TAB

BOLT DOWN
ATTACHMENT TAB
-SEE DETAIL

HEX COUPLING NUT


S. S. 5/16 NC x 7/8" WITH
s. s. 5/16 NC X 3/4" BOLT
& S. S. 5/16" FLAT WASHER

DETAIL

3/8" X 3" HEADED


ANCHOR SHEAR
STUD - WELDED
TO LIP PLATE

7/16" X 3/4"
SLOT

LID SUPPORT- L SHAPE


SHOWN (SEE NOTE 3)

WWR 4x4-W2.9xW2.9
(TYP.) (6 GAGE)
-SEE NOTE 10
3/8" X 3" HEADED
ANCHOR SHEAR
STUD- WELDED
TO LIP PLATE

1 1/2

~1

....................

3 3/4"

LOCKING LID STANDARD


DUTY JUNCTION BOX
TYPES 1 & 2
STANDARD PLAN J-40.10-03

I~.
1/2" S. S. _ /
HEX NUT

ALTERNATIVE 3
LID BOLT DOWN ATTACHMENT TAB
(SEE NOTE 12)

1/8" x 3/4" STEEL ANGLE


- MIRROR IMAGE FOR
LEFT ANGLE

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

~---------------------------A--------------------------~

0:::

<C
::I!

G
LOCKING BOLT
(TYP.)- SEE
DETAIL D

(J

LL

:~:C

----

----

u~

,__ f_~_~" -r

1.

I
I

.!.. __

~-~~

in ~
-+>- - '--

()

II

Ci

--

34"

37 7/16"

44"

JUNCTION BOX LENGTH

31"

40 7/16"

48"

JUNCTION BOX WIDTH

26"

29 7/16"

36"

LID OPENING LENGTH

24"

33 1/4"

41 1/8"

LID OPENING WIDTH

19"

22 1/4"

29 1/4"

TYPE 4 LID LENGTH

24"

--

--

TYPE 4, 5 & 6 LID WIDTH

19"

22"

29"

TYPE 5 & 6 LID LENGTH

--

167/16"

20 3/8"

~
en

INSIDE BOX LENGTH

19"

28 7/16"

36"

INSIDE BOX WIDTH

14"

17 7/16"

24"

STIFFENER SPACING

VARIES

VARIES

VARIES

-0~

STIFFENER SPACING

VARIES

VARIES

VARIES

STIFFENER LENGTH

18 1/4"

20 1/4"

28 1/8"

CAPACITY- CONDUIT DIAM.

6"

12"

24"

I
I

II

o\

___ - -

----

----

()

II
I

I
I
I
I
I

\:

II

C1

----e-- - -

II

{_'j

\__ SEE DETAIL B

f--L
a.:

t=

0
0

Equipment Grounding Conductor

4. The installed lid and frame shall fit with full even contact around the perimeter of a junction box after installation. Care shall be taken to prevent
debris accumulation on the contact surfaces.
5. A 1/4-20 NC x 3/4" S. S. ground stud shall be welded to the bottom of
each lid: include (2) each S. S. nuts and (2) each S. S. flat washers.
6. The hinges shall allow the lids to open 180.
7. Bolts and nuts shall be liberally coated with anti-seize compound.
8. Connect Equipment Bonding Jumper to ground stud on lid. As an alternative to ground stud connection, the Equipment Bonding Jumper shall be
attached to the front face of the hinge pocket with a 5/16-20 NC x 3/4"
S. S. bolt, (2) each S. S. nuts, and (2) each S. S. flat washers. Equipment
bonding jumper shall be #8 AWG min. x 4' of tinned braided copper.
9. The System Identification letters shall be 1/8" line thickness formed by
engraving, stamping, or with a S. S. weld bead. See Cover Marking
details. Grind off diamond pattern before forming letters. See Standard
Specification 9-29.2(4) for details.

12. Distance between the top of the conduit and the bottom of the Junction Box lid shall be
6" min. to 8" max. for final grade of new construction only. See Standard Specification
8-20.3(5). Where adjustments are to be made to existing Junction Boxes, or for interim
construction stages during the contract, the limits shall be from 6" min. to 10" max. See
Standard Specification 8-20.3(6).

Copper Solderless Crimp Connector

~ Equipment Bonding Jumper - see note 8

TOP VIEW
LOCKING BOLT
-SEE DETAIL D

3. Lid stiffener plates shall bear on frame. Mill to bearing seat and perimeter
bar for full even contact after fabrication of frame and lid. Lid and frame
units with uneven bearing will be rejected.

11. Unless otherwise noted in the plans or approved by the Engineer, Junction Boxes, Cable
Vaults, and Pull Boxes shall not be placed within the traveled way or paved shoulders.
All Junction Boxes, Cable Vaults, and Pull Boxes placed within the traveled way or paved
shoulders shall be Heavy-Duty. Heavy-Duty Junction Boxes shall not be installed in sidewalks, walkways, and shared use paths.

''

2. All lid thicknesses are minimum. The diamond pattern shall be 3/32"
minimum thickness.

10. See Standard Specification 9-29.2(1)B for class of concrete.

SEE DETAILC

[lj

---

I
7 STUDS EVENLY SPACED

LO

~~

I
I

I0 I
I
I

---

-, ,-----===:. __ )

r---~

1(1
I

I
1" (TYP.)

OVERALL WIDTH

~-----,

11Q11

""'----+--- - -

Ill
)I
I
I
~~~~
--

--=-- - - r-----

(" \\

'~

56"

I
I
I
I

~---...!

I
(--.,
0
- - 1---l----l>,.J
I

TYPES

48 7/16"

I
I

\_SEE
NOTES

TYPES

39"

~-----~

--

I
I
I
I
I_

TYPE4
OVERALL LENGTH

I
I
I
I
I'" I

1. All box dimensions are approximate. Exact configurations vary among


manufacturers.

BOX TYPE
ITEM

1/8" GAP
BETWEEN LIDS

~)

0
0

NOTES

JUNCTION BOX DIMENSION TABLE

See Contract Plans and Special Provisions


for conduit size and number

ROADWAY
SURFACE
DIAMOND PATTERN
-SEE NOTE2

WELDED WIRE
REINFORCEMENT
(WWR) 4 X 4 - W5 X W5

HINGE -SEE DETAIL E


(NOTE 6)

HEAVY-DUTY JUNCTION
BOX TYPES 4, 5, & 6
STANDARD PLAN J-40.20-01
SHEET 1 OF 2 SHEETS
4

GRS CONDUIT

APPROVED FOR PUBLICATION

SECTION

ISOMETRIC VIEW
TYPE 5 AND 6 SHOWN

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

05-17-12
DATE

. . . Washington State Department of Transportation

(2) S. S. NUT (TYP.)


SEE NOTE 3

1 1/2" DIAM. HOLE

ALTERNATE LOCATION FOR


EQUIPMENT BONDING JUMPER

(3) S. S. WASHER (TYP.)

LID
FRAME (OUTER) L 2" x 2" x 1/4" - SEE NOTE 4

GROUND STUD WITH NUT


-SEE NOTES
LID

STIFFENER PLATE
-SEE NOTE 3

FRAME (INNER) L 3" x 3" x 1/4"

J
WWR - TIED IN 2 PLACES
TO FRAME STUD (TYP.)

S. S. PIN W/ SNAP
RING GROOVE

HEX COUPLING NUTS. S. 5/16 NC x 7/8"


WITH S. S. 5/16 NC x 3/4" BOLT WITH (4)
EACH S. S. FLAT WASHERS

9/16" BOLT HOLE


FRAME STUD- 3/8" DIAM. x 8"

SNAP RING

SEE NOTE 9
EQUIPMENT BONDING JUMPER
FROM OTHER LID

DETAIL

HANDLE SLOT

DETAIL

HINGE

COVER MARKING
DETAIL
PLAN VIEW

r-

=1" (TYP.).

LID

=1" (TYP.)

HANDLE- BENT 1/2" STEEL


ROD, LEVEL WITH LID
PENTA HEAD BOLT

lli s_[
1/2" (TYP.)

1=--f

BOLT PLATE3" x 2 1/2" x 1/2" THICK

WASHER-S. S.
1 7/16" 0. D. x 1/2" I. D. x 1/8"

2 3/4"

HANDLE STOP 3 3/4" )( 2" )( 1/4"

HOLE - 3/4" DIAM.


(TYP.)

LID

SEE NOTE9

(TYP.)

1/4
HANDLE

3/8" (TYP.)

I~
SECTION

STIFFENER PLATE
(TYP.)

11/2"

1" )( 1" )( 1/4"


(TYP.)

1/4" x 3" CHANNEL

DETAIL

S. S. CHANNEL NUT
WITH S. S. SPRING

DETAIL

TOP VIEW

1/2" -13 )( 1 1/2"


PENTA HEAD BOLT

LOCKING BOLT

STIFFENER PLATE
(TYP.)
EDGE OF LID

HEAVY-DUTY JUNCTION
BOX TYPES 4, 5, & 6
STANDARD PLAN J-40.20-01

1/2" (TYP.)
3/8" (TYP.)

SHEET 2 OF 2 SHEETS

1---------z--------------~

FRAME STUD (TYP.)

SECTION

FRAME (OUTER)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


VIEW

______

-~------s=T~M=E-DE~SI~GN-E-NG~IN-E-ER

05-17-12
DATE

. . . Washington State Department of Transportation

48"

lr

42"
GROUND STUD (TYP} \
-SEE NOTE 4

36"
\

---------------------

1\

. .- - - - - - - - - - - - - - - - - - - r -

SEE HINGE DETAIL

r- : :

:::: 1" (TYP.}

I/

1/8" GAP
BElWEEN LIDS

NOTES

COVER MARKING
DETAIL

ITS_[
1t2" <TYP.>
SEE NOTES

I ~f

1. All box dimensions are approximate. Exact configurations vary among manufacturers.
1" (TYP.}

2. Minimum lid thicknesses are shown. The diamond pattern shall be a minimum of 28% of the
overall thickness. Junction Boxes installed in sidewalks, walkways, and shared-use paths shall
have a slip-resistant coating on the lid and lip cover plate and shall be installed with the surface
flush with and matched to the grade of the sidewalk, walkway, or shared-use path. The non-slip
lid shall be identified with permanent markings on the underside, indicating the type of surface
treatment (see Contract Documents for details) and the year of manufacture. The permanent
marking shall be 1/8" inch line thickness formed with a stainless steel weld bead and shall be
placed prior to hot-dip galvanizing.

3. Lid support members shall be 3/16" min. thick steel C, L, or T shape, welded to the frame. Exact configurations vary among
manufacturers.

~
z

4. A 1/4-20 NC x 3/4" S. S. ground stud shall be welded to the bottom of each lid; include (2) S. S. nuts and (2) S. S. flat washers.

6. Bolts and nuts shall be liberally coated with anti-seize compound.

5. The hinges shall allow the lids to open 180.

::J
-

11..
11..

7. Connect Equipment Bonding Jumper to ground stud on lid. As an alternative to the ground stud connection, the Equipment
Bonding Jumper shall be attached to the front face of the hinge pocket with a 5/16-20 NC x 3/4" S. S. bolt, (2) each S. S. nuts,
and (2) each S. S. flat washers. Equipment Bonding Jumper shall be #8 AWG min. x 4' of tinned braided copper.

~0

:I:
10

s:w

8. The System Identification letters shall be 1/8" line thickness formed by engraving, stamping, or with aS. S. weld bead. See
Cover Marking detail. Grind off diamond pattern before forming letters. See Standard Specification 9-29.2(4) for details.

0
Ci)

9. See the Standard Specifications for alternative reinforcement and class of concrete.
10. See Standard Plan J-40.1 0 for Welded Wire Reinforcement and Headed Anchor Shear Stud attachment details.

~-------------------r- ~

;I

I I \

\~r-----------

1\

'

HEADED ANCHOR SHEAR STUD


- 3/8" x 3", 10 COUNT STUDS
EVENLY SPACED AROUND FRAME

..........11

(TYP.}

Equipment Grounding
Conductor

~ Equipment Bonding Jumper

DIAMOND PATTERN
- SEE NOTE 2

12. Lid Bolt Down Attachment Tab provides a method of retrofitting by using a mechanical process in lieu of welding. Attachment
Tab shown depicts a typical component arrangement; actual configurations of assembly will vary among manufacturers. See
approved manufacturers' shop drawing for specifics.

~~

13. Unless otherwise noted in the plans or approved by the Engineer, Junction Boxes, Cable Vaults and Pull Boxes shall not be
placed within the sidewalk, walkway, shared use path, traveled way or paved shoulders. All Junction Boxes, Cable Vaults, and
Pull Boxes placed within the traveled way or paved shoulders shall be Heavy-Duty.

1~_____
19'_'----~------19_"----~1
1"
(TYP.}

If-,._ _ _ _ _4__:_...:....._cc..__
STUDS EVENLY
SPACED
_
_____:______:_ _ _ _ _

~.,

14. Distance between the top of the conduit and the bottom of the Junction Box lid shall be 6" min. to 8" max. for final grade of new
construction only. See Standard Specification 8-20.3(5). Where adjustments are to be made to existing Junction Boxes, or for
interim construction stages during the contract, the limits shall be from 6" min. to 10" max. See Standard Specification 8-20.3(6).

PLAN VIEW

~ Copper Solderless Crimp


Connector

\_

3/16 V1 1/2

I'

11. Capacity - conduit diameter = 24"

[i

LOCKING LID STANDARD DUTY JUNCTION BOX

Foundation

~ See Contract for conduit size


and number

HEX COUPLING NUT


(TYP.} - SEE DETAIL "C"

42"
3" (TYP.}

TOP OF SOIL SURFACE

1/2" STEEL
COVER PLATE
(TYP.}

LIFTHO~
[)lAM.

1"- 2"

30"
20"

TOP OF BASE COURSE

INSIDE WIDTH OF FOUNDATION


3" (TYP.}
TOP OF PAVED
SURFACE

GROUND STUD
WELDED WIRE
REINFORCEMENT (TYP.}
(WVVR} 4x4-W2.9 (6 GAGE}
- SEE NOTE 9

#5 HOOP WITH
8" OVERLAP2 TIES

WELDED WIRE HOOP


(TYP.} W2.9 (6 GAGE}
- SEE NOTE 9

LOCKING LID STANDARD


DUTY JUNCTION BOX
TYPES
STANDARD PLAN J-40.30-03
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

PVC CONDUIT

GRS CONDUIT

SECTION

SECTION

CONDUITS NOT SHOWN

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

ALTERNATE LOCATION FOR ATTACHMENT


OF EQUIPMENT BONDING JUMPER
- SEE NOTE 7

3/16
LID SUPPORT- 3/16" MIN. THICK

L 1 3/4"

5"

1/2" STEEL
COVER PLATE

HANDLE STOP
- 6" X 3" X 1/4"

1/2" STEEL COVER PLATE

FRAME1/2" X 3/16"

HOLE - 3/4" DIAM.


(TYP.)

S. S. PIN W/ SNAP
RING GROOVE

TOP VIEW
HANDLE STOP

GROUND STUD WITH 2 NUTS AND


2 WASHERS (TYP.) - SEE NOTE 4

SNAP RING

1/2" STEEL
COVER PLATE

HANDLE - BENT 1/2" STEEL


ROD, LEVEL WITH LID

WNR- TIED IN 2 PLACES


TO HEADED ANCHOR
SHEAR STUD (SEE NOTE 10)
EQUIPMENT BONDING JUMPER (TYP.)
- SEE NOTE 7

HINGE DETAIL

3/8" x 3" HEADED ANCHOR


SHEAR STUD - WELDED TO
LIP PLATE (SEE NOTE 10)

<J
<J

I.

.I

3"

HEX COUPLING NUT-S. S. 5/16 NC x 7/8"


WITH S. S. 5/16 NC x 3/4" BOLT (TYP.)

DETAIL

1"

1/4" (TYP.)

FRONT VIEW

HANDLE DETAIL

~I ~1
1 1/2"

1"

5/8" X 1"
VERTICAL
SLOT

- - -i~

BOLT PLATE CHANNEL

2 1/4"

1 3/8"

If---._ 2 _ "

1/2 - 13 x 1 1/2 S. S. PENTA HEAD BOLT


AND 1/2" S. S. FLAT WASHER

3/16
LID SUPPORT - 3/16" MIN. THICK

L 1 3/4"

1/2- 13 X 1 1/2 S. S. PENTA


HEAD BOLT AND 1/2" S. S.
FLAT WASHER I

FRAME1/2" X 3/16"

HANDLE- SEE DETAIL


1/2" STEEL COVER PLATE

1/2" STEEL COVER PLATESHOWN CUT AWAY FOR CLARITY

L 1 3/4"
BOLT PLATE
CHANNEL

WNR- TIED IN 2 PLACES


TO HEADED ANCHOR
SHEAR STUD (SEE NOTE 10)

SLOTTED S. S. CHANNEL
WITH S. S. CHANNEL NUT
AND SPRING

<J

FRAME1/2" X 3/16"

LID SUPPORT 3/16" MIN. THICKNESS


HANDLE STOP
- 6" X 3" X 1/4"

'

1 3/8" DIAM. HOLE

5/8" X 1"
VERTICAL SLOT

BOLT PLATE CHANNELWELD TO STEEL COVER PLATE

q '

3/8" x 3" HEADED ANCHOR


SHEAR STUD -WELDED TO
LIP PLATE (SEE NOTE 10)

<J
-~

SLOTTED S. S. CHANNEL
WITH S. S. CHANNEL NUT
AND SPRING

<J

I.

3"

.I

5/8" X 1"
HORIZONTAL SLOT

DETAIL

LOCKING LID STANDARD


DUTY JUNCTION BOX
TYPES
STANDARD PLAN J-40.30-03
SHEET 2 OF 2 SHEETS

DETAIL

ISOMETRIC VIEW

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

POST-MOUNTED JUNCTION
BOX - SEE NOTE 1
TIMBER SIGN POST (TYP.)

1. Install the Junction Box on the Timber Sign Post or the Steel Sign
Support that is farthest from the roadway.

CONCRETE
ANCHOR

CONDUIT BODY OR
FLASHER CABINET
(SEE CONTRACT)

II
II
II

TO CONDUIT RUN
ALONG ROADWAY

BOTTOM OF
SIGN PANEL

NOTCH IN POST - SEE


STANDARD PLAN G-22.10

SECURE THE SIGN LIGHTING CONDUCTORS


TO THE CONDUIT WITH A CABLE TIE SEE STANDARD PLAN J-28.70, DETAIL "A"

SEAL TITE FLEX


CONDUIT

TIMBER SIGN POST

PLAN
STAINLESS STEEL
2 HOLE CONDUIT
STRAPS (TYP.)

STAINLESS STEEL 2 HOLE


CONDUIT STRAPS (TYP.)ATTACH TO THE POSTW/2 LAG
BOLTS, 1/4" DIAM. x 1 1/2" LONG

EDGE OF
TRAVELED WAY

1" RIGID METALLIC


CONDUIT (RMC)
11

&,~
,-~-~-~-~c========~ C--------~~-L ----~
II

1#:

Ill
lui
111 1
1 I

I
I I
I I
I

~----" : c========~
111 1
lui
111 1
111 1
1 I

c----1 ::

I
I
I
I

c========~

lui
111 1
1 I
.[ll

POST-MOUNTED
(NEMA 3) J-BOX

c=========11
I
I
1
I

c=========1

I I
I I
I
I I

1" DIAMETER PVC


SCHEDULE 40 CONDUIT

~
A

L-_-_:o

I I
I I
I I

-1+!-f-------

-~ l\,lc==================f:::::::::=:=:=:=:=:=:~ ~---

c-_-

...::o

HOLES DRILLED
THROUGH POST - SEE
STANDARD PLAN G-22.10

RIGID METALLIC
CONDUIT ATTACHED
TOPOST

0
'

&,

'

:~~~

1
I

:I:

I I

:
I
I
1

I I
I I

I I I

i i CONCRETE~
11

ANCHOR

II

L J

-,

[~z-:--/

~ i ~~ ~

:L-

::1

1"

//

i ~

!~

:
:

CONCRETE
CLASS 3000

I
I

1 1
I I
1
:
I I
I I

: :

1 1

1"DIAM.PVC
CONDUIT

_..J

DC_jl'b-~--D-p~-~~-_;- L~~=-0" STAN~~~J~".,:~~~

~~

'------~::

CONNECT THE EQUIPMENT


GROUNDING CONDUCTOR
TO THE GROUNDING
SYSTEM IN THE TYPE 1
JUNCTION BOX
1" DIAMETER PVC
SCHEDULE 40 CONDUIT

JUNCTION BOX
INTERNAL DETAIL

SIGN POST-MOUNTED
JUNCTION BOX
STANDARD PLAN J-40.35-01

PVC CONDUIT ENTRANCE


INTO CONCRETE ANCHOR

SHEET 1 OF 3 SHEETS
TIMBER
SIGN POST

ELEVATION

JUNCTION BOX ATTACHMENT


TO TIMBER SIGN SUPPORT

:----~::' ___ _

PVC CONDUIT COUPLINGINSTALL FLUSH WITH TOP


OFFOUNDATION

1
I
1

1,1
Ill
I I

: _ //

I I

MOUNTING
BOLT (TYP.)

TOP OF CONCRETE ANCHOR

I I
I I

LUG

END BELL BUSHING - DO NOT


GLUE BUSHING TO CONDUIT

1" DIAMETER PVC


SCHEDULE 40 CONDUIT

2" CHAMFER - SEE


STANDARD PLAN G-25.10

1/4" DIAM.
GROUNDING

INSTALL IN PVC COUPLING DO NOT GLUE PVC CONDUIT

GROUND LINE

TIMBER SIGN ~
POST (TYP.)
-......

L...._____._ _
QUICK
DISCONNECTS

1 1/2" DIAM. HOLE IN BOX


W /2" 0. D. GASKET TIGHT ON
CONDUIT. GASKET SEALED
TO CONDUIT AND BOX WITH
A BEAD OF SILICONE
DRILLED
HOLE (TYP.)

r_-_-::.

I
I
I
I
I

1/4" WEEP HOLE

NEMA 3 J-BOX- ATTACH TO THE POST


W/4 LAG BOLTS, 1/4" DIAM. x 2 1/2" LONG
(SEE INTERNAL DETAIL, THIS SHEET)

I I
I I

I
I
I
I
I

PROVIDE 2" THREAD ON


CONDUIT- SECURE THE
CONDUCTORS TO THE
CONDUIT WITH A CABLE TIE
(SEE STANDARD PLAN J-28.70,
DETAIL "A")

HINGED COVER

II

:11:
~
--f--!11------,I

I :

1" RIGID METALLIC


CONDUIT (RMC)

Cn

SIGN PANEL\

6" X 6" X 8" NEMA 3


JUNCTION BOX
WI HINGED LID

WATER-TIGHT
CONDUIT NUTS

;....'

TYPE 1 JUNCTION BOX - SEE CONTRACT


OR STANDARD PLAN J-40.10

6"

CONDUIT BODY
(SHOWN)

SIGN POST
NOTCH

SEAL TITE FLEX


CONDUIT

1"PVC~:

CONDUIT

2. See Standard Plan J-21.16 for Flashing Beacon Installation


details. See Standard Plan J-21.17 for Electrical Wiring details.

SIGN PANEL

II
II
II

SIGN PANEL

NOTE

TIMBER SIGN POST

CONCRETE ANCHOR

1" DIAMETER PVC


SCHEDULE 40 CONDUIT

SECTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


STATE DESIGN ENGINEER

5129113
DATE

.....
f
.
. . . Washington State Department o Transportation

CONCRETE
FOUNDATION

0
0:::
0

STEEL SIGN SUPPORT (TYP.)

LL.

>-

STEEL SIGN
SUPPORT

POST-MOUNTED
JUNCTION BOX SEE NOTE 1

()

<(

en

CONCRETE
FOUNDATION

CONDUIT BODY
(SHOWN)

SIGN PANEL

STAINLESS
STEEL
STRAP

::::i

>
ID

()

CONDUIT BODY OR
FLASHER CABINET
(SEE CONTRACT)

II
II

u:::

LL.

1"PVC~:

SIGN PANEL

CONDUIT

1-

II
II
II

POST-MOUNTED
(NEMA 3) J-BOX

BREAKAWAY SIGN
SUPPORT HINGE
(TYP.)

'
II

BREAKAWAY SIGN
SUPPORT HINGE (TYP.)SEE STANDARD PLAN G-24.60

TO CONDUIT RUN
ALONG ROADWAY
SECURE THE SIGN LIGHTING CONDUCTORS
TO THE CONDUIT WITH A CABLE TIE SEE STANDARD PLAN J-28.70, DETAIL "A"

STEEL SIGN
SUPPORT

TYPE 1 JUNCTION BOX - SEE CONTRACT


OR STANDARD PLAN J-40.10

1" RIGID METALLIC


CONDUIT

SEAL TITE FLEX


CONDUIT

SEAL TITE FLEX


CONDUIT

SLOTTED STAINLESS STEEL


CHANNEL BRACKET- LENGTH
SIGN SUPPORT WIDTH + 3/8"

SECTION

CONDUIT CLAMP SUPPORTSLOTTED STAINLESS STEEL


CHANNEL BRACKET AND
STAINLESS STEEL STRAP (TYP.)

EDGE OF
TRAVELED WAY

..

\)'

....

STEEL SIGN
SUPPORT

PLAN

STAINLESS STEEL
2 HOLE CONDUIT
STRAPS (TYP.)

STEEL SIGN
SUPPORT

SIGN PANEL
1" RIGID METALLIC
CONDUIT (RMC)

STAINLESS STEEL
2 HOLE CONDUIT
STRAPS (TYP.)- SEE
STANDARD PLAN J-60.13

POST-MOUNTED
(NEMA 3) J-BOX
CONDUIT CLAMP SUPPORTSLOTTED STAINLESS STEEL
CHANNEL BOX SUPPORT AND
STAINLESS STEEL STRAP (TYP.)

STAINLESS STEEL
STRAP (TYP.)

1" RIGID METALLIC


CONDUIT (RMC)

CONDUIT CLAMP
SUPPORT (TYP.)

SLOTTED STAINLESS
STEEL CHANNEL BRACKET

NEMA 3 J-BOX- ATTACH TO THE CHANNEL


WI FOUR 1/4" DIAM. x 1" LONG HEX HEAD
BOLTS (SEE INTERNAL DETAIL, SHEET 1)

3/4" STAINLESS STEEL


STRAP (TYP.)

1" DIAMETER PVC


SCHEDULE 40 CONDUIT
1" DIAMETER PVC
SCHEDULE 40 CONDUIT
BREAKAWAY SIGN BASE (TYP.)SEE STANDARD PLAN G-24.60

INSTALL IN PVC COUPLINGDO NOT GLUE PVC CONDUIT

2" CHAMFER - SEE


STANDARD PLAN G-25.10
1" RIGID METALLIC
CONDUIT ATTACHED
TO POST

STEEL SIGN
SUPPORT
(TYP.)

GROUND LINE

'~~~!--~:

f.--.!1.-l"------:~-II

II

PVC CONDUIT

I
I
I

:1:

II

ll'l

::

: :

::

}i}

I
I
I
I

I
I
I
I

I
I
I
I
L _____ l

I
I
I
I
L _____ l

--

----l---~3Jr----;;/ I

XI

L------ -1--------

....J
1

~i

SIGN SUPPORT CONCRETE


FOUNDATION- SEE

--~

/}

I
I
I

BREAKAWAY
SIGN BASE

TOP OF CONCRETE
FOUNDATION

POST-MOUNTED
JUNCTION BOX SEE NOTE 1

BREAKAWAY
SIGN BASE
(TYP.)

'

11
II
II

/
(-/-:+

PVCCONDUIT-

11~!
:
~

INSTALLFLUSHWITHTOP
OF FOUNDATION

1" DIAMETER PVC CONDUIT


I

I
-------,:
- - - .... ::. :_)
-----________ ....

II II
II II
,
--...W-Il--).......U---------'1

1
1

I
I
ANCHOR FERRULE (TYP.):
:
SEESTANDARDPLANG-24.6y:

_:~-~~

1
I
I

SIGN SUPPORT
CONCRETE FOUNDATION SEE STANDARD PLAN G-25.10

tJ

0
-----~ l',_______ _- . . ::. :_--- - ''l
....
1

STANDARD PLAN G-25.10

L----- ~ SIGN SUPPORT CONCRETE

VIEW0

SLOTTED STEEL
CHANNEL ATTACHMENT
DETAILS

SLOTTED STAINLESS
STEEL CHANNEL
BOX SUPPORT (TYP.)

VIEW

SIGN POST-MOUNTED
JUNCTION BOX
STANDARD PLAN J-40.35-01
SHEET 2 OF 3 SHEETS

FOUNDATION (TYP.)

ELEVATION

JUNCTION BOX ATTACHMENT


TO STEEL SIGN SUPPORT

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

8" FLASHING BEACON WITH CAP VISORSEE NOTE2

VARIES- SEE CONTRACT

8" FLASHING BEACON (TYP.)SEENOTE2

-~

-oa.:

-' ~

;....

.,....~

1"CONDUIT

~====~--------------~==~------------------~.---~r~--------~
.--- f--

?ic1-----~

/;=lie

Fill=

~------------------~

STAINLESS STEEL CONDUIT


STRAP SUPPORT (TYP.)

I-

STAINLESS STEEL 2 HOLE


CONDUIT STRAP (TYP.)

{)

I-

SIGN PANEL

{)

w
w

en
I
en
w

0::

cONDUIT ~ ?lc
BODY

==

= =

rgl

'~------------~Ho
SLOTTED STAINLESS STEEL
\ _ CONDUIT STRAP SUPPORTSTRAPPED VERTICALLY
TO SIGN POST (TYP.)

SEAL TITE FLEX


CONDUIT

STAINLESS STEEL
2 HOLE CONDUIT
STRAPS

POST-MOUNTED
(NEMA 3) J-BOX

BREAKAWAY SIGN
SUPPORT HINGE

I
V

~~ff_~li:t::==~

SEAL TITE
FLEX CONDUIT

o o

~ STEEL SIGN

SUPPORT (TYP.)

STAINLESS STEEL
STRAP (TYP.)
POST-MOUNTED
(NEMA 3) J-BOX

--....

SIGN POST-MOUNTED
JUNCTION BOX
STANDARD PLAN J-40.35-01
SHEET 3 OF 3 SHEETS

ELEVATION

APPROVED FOR PUBLICATION

VIEW0

Pasco Bakotich Ill

FLASHING BEACON ATTACHMENT

RIGHT ISOMETRIC VIEW

(STEEL SIGN SUPPORT SHOWN)

TRAVELER INFORMATION SIGN SHOWNSEE CONTRACT FOR SIGN MESSAGE AND SIZE

.....

STATE DESIGN ENGINEER

5129113
DATE

. . . Washington State Department of Transportation

NOTES

18"
EQUIPMENT BONDING JUMPER
CONNECTION - SEE SINGLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

6 1/2"
DRAIN TUBE

1. Junction Box shall be constructed of 12-gage, Type 304


stainless with steel welded seam construction. Finish shall be
# 2B for backbox and # 4 for the cover. Mounting Tabs shall
be constructed of 12-gage, Type 304 stainless steel.

SEALING LOCK NUT (TYP.)

LOCK NUT - SEAL WITH


BEAD OF SILICONE CAULK
(TYP.) - SEE NOTE 3

2. Holes for conduit(s) shall be field drilled or punched in the


box ends. See Section B.
3. Fittings shall be UL listed and GSA-certified concrete tight on
the outside of the Junction Box conduit connection. Use an
insulated, grounded end bushing on the inside for GRS
conduit. Use a sealing lock nut and a rigid PVC conduit
bushing on the inside for PVC conduit.

NON-INSULATED GROUNDING
CONDUCTOR CONNECTION FOR DETAILS - SEE SINGLE
BONDING JUMPER CONNECTION
DETAIL, STANDARD PLAN J-40.40

1 1/2" )( 1 1/2" )(
1 1/2" x 12-GAGE
STAINLESS STEEL
MOUNTING TAB
(TYP.)

4. The System Identification letters shall be 1/8" line thickness


formed by engraving, stamping, or with a stainless steel weld
bead. See Standard Specification 9-29.2(4) for details.
5. Liberally coat the threads of the cover fasteners with anti-seize
compound during construction and before final closure.

SYSTEM IDENTIFICATION
-SEE NOTE 4

NEOPRENE

GASKET~

ISOMETRIC VIEW

REINFORCING
STEEL (TYP.)

SHOWN MOUNTED IN REINFORCING STEEL

1
0

Equipment Grounding Conductor

1
PLAN VIEW

~ Copper Solderless Crimp Connector

7. Conduit Capacity= 8" (4" per end).

JUNCTION
BOX WALL

MOUNT BOX SO COVER IS FLUSH


WITH BARRIER FACE WITH A 0"
TOLERANCE PROTRUDING BEYOND
BARRIER FACE AND 1/8" RECESSED

1/4- 20 NC x 1" STAINLESS


STEEL SEALED WELL NUT
WITH A DAM AT REAR TO
PREVENT CONCRETE
INFILTRATION- TACK
WELD (3) PLACES

~ Equipment Bonding Jumper


1 1/4" x 1/4" CLOSED CELL
NEOPRENE GASKET

~ Equipment Bonding Jumper - Omit


when PVC Conduit installed

~ See Contract for conduit size

1/4- 20 NC x 1" STAINLESS STEEL


PHILLIPS PAN HEAD SCREW (TYP.)

and number

~ # 8 AWG Stranded, Non-insulated


Grounding Conductor - See Note 9

~- _

8. Conduits shall only enter Junction Box from ends as shown.


SEALING
LOCKNUT

BEAD OF SILICONE
CAULK

COVER

DETAIL

ALTERNATIVE PVC
CONDUIT DETAIL

1 1/2" x 1 1/2" x 1 1/2" x 12-GAGE


MOUNTING TAB WITH A 0.5" DIAM.
HOLE (TYP.)

20"

6 3/8"

9. When converting RMC to PVC in Stationary-Form Barriers,


route a# 8 Stranded, Non-Insulated Grounding Conductor
along Conduit, secure Conductor to Conduit with clamp as
shown on Conduit Deflection Fitting "B" detail, convert RMC to
PVC in Stationary-Form Barrier (per Standard Plan J-60.11):
omit Conductor when this detail is not used.

RIGID PVC
CONDUIT
BUSHING

PVC CONDUIT 5
PVC MALE ADAPTER

TAPE (4) SPARE 1/4- 20 NC x 1"


STAINLESS STEEL PHILLIPS PAN
HEAD SCREWS TO INSIDE BACK~
OF BOX
8

6. Junction Box shall only be used in barriers with stationaryforms. If Slip-Form Traffic Barrier is required, use Conduit
shown in the Alternative PVC Conduit detail.

1/4"
(TYP.)

6 1/4"

3/8" DIAM.
HOLE (TYP.)

1/4- 20 NC x 1" STAINLESS STEEL


PHILLIPS PAN HEAD SCREW (TYP.)

3 1/8"

SF"

POSSIBLE CONDUIT LOCATION


- SEE CONTRACT PLANS FOR
NUMBER AND SIZE

.....

NEMA4X
NON-AD.JUSTABLE
FLUSH-MOUNT
.JUNCTION BOX
STANDARD PLAN J-40.36-01

io
.....
j::::

NEOPRENE GASKET

.....

SYSTEM IDENTIFICATION
DETAIL
FIELD DRILL 1/2" DIAM. HOLE FOR
DRAIN TUBE FROM THE INSIDE TO
OUTSIDE- ONE SIDE ONLY IN LOWEST
CORNER, SEAL WITH BEAD OF SILICONE
(SEE STANDARD SPECIFICATION 9-29.2(3))

VIEW0

-1"(TYP)

. I

SHEET 1 OF 1 SHEET

:::: 1"(TYP.)

~_I

I T S
1/2" (TYP.) ! ~f
1

SEE NOTE4

COVER

MOUNTING TAB (TYP.)

DRAIN
TUBE

VERTICALLY CENTER AND MAINTAIN REQUIRED


SPACING WHEN INSTALLING MULTIPLE CONDUITS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

18"
EQUIPMENT BONDING JUMPER
CONNECTION - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

6.5"

LOCKNUT - SEAL
WITH BEAD OF
SILICONE CAULK
(TYP.)- SEE
NOTE 3

FIELD DRILL 1/2" DIAM. HOLE


FOR DRAIN FROM THE INSIDE
TO OUTSIDE - ONE SIDE ONLY
IN LOWEST CORNER - SEAL WITH
BEAD OF SILICONE (SEE STANDARD
SPECIFICATION 9-29.2(3))

NOTES

20"

06433""

I"

-----___::::6.=23:..:._78~"--_,+1----~6~.2~3~78._"

---I

r-1-----'6:..:.:.2:.=3.:....:78=--"-----+1

"

--.------,--__.L_ _

i--------~----1

in

[8
M

-.:i

t---------1--------~---------+

i'

i,

:ceMML _______

-------

SYSTEM I.D.

'

I
I

0.375" DIAM. HOLE


- (10) TOTAL

i (TYP.)

2. Holes for conduit(s) shall be field drilled or


punched in box ends. See SIDE VIEW.
3.

'

i,

1. Junction Box shall be constructed of 12- gage,


Type 304 stainless steel with welded seam
construction. Finish shall be # 2B for backbox
and# 4 for the cover. Mounting Tabs shall be
constructed of 12-gage, Type 304 stainless steel.

4. The System Identification letters shall be 1/8" line


thickness formed by engraving, stamping, or with
a stainless steel weld bead. See Standard
Specification 9-29.2(4) for details.
5.

MOUNTING
TAB (TYP.)
(1) 5/8 NC x 3/4" STAINLESS
STEEL STUD WITH
(1) STAINLESS STEEL NUT AND
(2) STAINLESS STEEL WASHERS
- (4) PLACES TOTAL

TOP VIEW

SEE STANDARD PLAN J-40.40SINGLE BONDING JUMPER


CONNECTION DETAIL FOR
DETAILS NOT SHOWN

ADJUSTMENT TAB SEE DETAIL

ADJUSTMENT TAB
MOUNTING DETAIL

-I
~t.

(JUNCTION BOX SHOWN WITHOUT


ADJUSTABLE FACE FOR CLARITY ONLY)

10.6208
(TYP.)

'

~ ~:
SECTION

ADJUSTMENT TAB (TYP.) -SEE DETAIL

-1

TAPE (4) SPARE 1/4- 20 x 1" STAINLESS STEEL


PHILLIPS PAN HEAD SCREWS TO THE BACK
INSIDE OF BOX

.. (TYP)

:::: 1" (TYP.)

0.5118"

ADJUSTMENT TAB
DETAIL

1/2" (TYP.)

13. Apply a 3/16" bead of caulk around Junction Box body and Adjustable
Face to provide a proper seal prior to installation.

ADJUSTMENT
TAB (TYP.)SEE DETAIL

1-f

SEE NOTE 4

12. When additional Conduits are required, Bonding and Grounding wiring
shall match configuration as shown in the perspective view. See
Contract for number and size of additional Conduits.

1 1/2" x 1 1/2" x 1 1/2" x 12-GAGE


MOUNTING TAB (TYP.)

. I f- _I
I~

11. When converting RMC to PVC in Stationary-Form Barriers, route a # 8


Stranded, Non-Insulated Grounding Conductor along Conduit, secure
Conductor to Conduit with clamp as shown on Conduit Deflection
Fitting "B"' detail, convert RMC to PVC in Stationary-Form Barrier (per
Standard Plan J-60.11): omit Conductor when this detail is not used.

1.75"

0.25" DIAM. RADIUS

SYSTEM IDENTIFICATION
DETAIL

- I '
:g"""
I
Nil.

10. Equipment Bonding Jumper shall be# 8 AWG (min.) x 1 foot of tinned,
braided copper.

~~-5/16" BOLT TACK


WELDED TO TAB

8. Conduits shall enter the Junction Box from the ends as shown.
9. This Junction Box type shall not be surface mounted. For SurfaceMounted Junction Boxes, see Standard Plans J-40.38 and J-40.39.

ADJUSTMENT
TAB

SECTION

7. Conduit capacity = 8".

PERMANENT COVER

JUNCTION
BOX WALL

SKEWED VIEW

Liberally coat the threads of the cover fasteners


with anti-seize compound during construction and
before final closure.

6. Detail shown for box installation is Slip-Form Traffic Barrier.

FRONT VIEW

12-GAGE, TYPE 304 STAINLESS


STEEL WITH # 4 FINISH

Fittings shall be UL listed and GSA-certified


concrete tight on the outside of the Junction Box
conduit connection. Use an insulated, grounded
end bushing on the inside for GRS conduit.

(1) 5/8 NC x 3/4" STAINLESS


STEEL STUD WITH
(1) STAINLESS STEEL NUT AND
(2) STAINLESS STEEL WASHERS
- (4) PLACES TOTAL

VERTICALLY CENTER CONDUIT


IN JUNCTION BOX- UNLESS
INSTALLING ADDITIONAL
CONDUITS

POSSIBLE CONDUIT LOCATION


- SEE NOTE 12

0
0

Equipment Grounding Conductor


Copper Solderless Crimp Connector

~ Equipment Bonding Jumper See note 10

5"

(1) 5/8 NC x 3/4" STAINLESS


STEEL STUD WITH
(1) STAINLESS STEEL NUT AND
(2) STAINLESS STEEL WASHERS
- (4) PLACES TOTAL

8"

FRONT VIEW

JUNCTION BOX

5"

EQUIPMENT BONDING JUMPER


CONNECTION - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

<9 Equipment Bonding Jumper


~ See Contract for conduit size
and number

~ # 8 AWG Stranded, Non-insulated


Grounding Conductor - See Note 11

1" (TYP.)

I
2.875"

3.5"
MAX.

3 ROUTE TO
GROUND STUD
ON ADJUSTABLE
FACE

NEMA 3R AD.JUSTABLE
FLUSH-MOUNT
.JUNCTION BOX
STANDARD PLAN .J-40.37-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

(TYP.)
SIDE VIEW
VERTICALLY CENTER AND MAINTAIN REQUIRED
SPACING WHEN INSTALLING MULTIPLE CONDUITS

-~---S~T~M~E~DE~SI~GN~E~NG~IN~E=ER~---

5120113
DATE

. . . Washington State Department of Transportation

ADJUSTABLE FACE

20.343"
0.8148"
(TYP.)

6.2378"

6.2378"

6.2378"

04055".111

1 1/4" x 1/4" CLOSED CELL


NEOPRENE GASKET
TEMPORARY COVER
JUNCTION BOX

- - - ~---------0---------~---------0i ~---------------- ----------------- ,----------------, !

~1[
0

'I

I GROUND STUD
1/4 INC x 3/4" STAINLESS STEEL
WITH STAINLESS STEEL NUT AND
(2) STAINLESS STEEL WASHERS

:
I

0.375" DIAM. HOLE


(TYP.) - (10) TOTAL

--1---------- +------3

ROUTE TO GROUND I
STUD ON BACK OF BOX

I
I

am-~-----

10- 32 NF x 3/8" STAINLESS


STEEL SELF-TAPPING
SCREW (TYP.) \
-(6) TOTAL

io ....,.

~c.

......

~ ~

ROUTE TO GROUND
STUD ON BACK OF BOX

FRONT VIEW

u.

SIDE VIEW

17.5884"

>(.)
4.6067"

<(

en

::::i

1.3773"

;>.:

7.625"

4.6067"

1/4-20 NC x 1" STAINLESS STEEL


PHILLIPS PAN HEAD SCREW (TYP.)
- (10) TOTAL

ASSEMBLY DETAIL

TEMPORARY
COVER

(TYP.)

Ill

-=---~~=~- --~--~---=--=-=--~~0
0::

TEMPORARY ACCESS
COVER

1/4 - 20 NC x 1"
STAINLESS STEEL
PHILLIPS PAN HEAD
SCREW

io
......

1 1/4" x 1/4" CLOSED CELL


NEOPRENE GASKET

TACK WELD NUTS


TO THREADED ROD

WASHER

_L

C'i

TOP VIEW

1/4 NC x 3/4" STAINLESS STEEL GROUND


STUD WITH STAINLESS STEEL NUT AND
(2) STAINLESS STEEL WASHERS

ADJUSTMENT BOLT DETAIL

MOUNT BOX SO COVER IS FLUSH


WITH BARRIER FACE WITH A 0"
TOLERANCE PROTRUDING BEYOND
BARRIER FACE AND 1/8" RECESSED

ADJUSTABLE FACE
20"

0.6433"

6.2378"

6.2378"

2.5"

6.2378"

15"

5/16" x 5 3/4" THREADED ROD

TEMPORARY
COVER

---,

0.6433"

DETAIL

1/4- 20 NC x 1" STAINLESS STEEL


SEALED WELL NUT WITH DAM AT
REAR TO PREVENT CONCRETE
INFILTRATION -TACK WELD
WELL NUT - (3) PLACES

2.5"
16"
5"

0.15625" DIAM. HOLE I


(TYP.) - (6) TOTAL I

6"

5"

io

'I

---a-

I
_L

ro--- I'

-------

,1

0.25"
(TYP.)

_j

f------

-------~-------~-------

I,

0.375" DIAM. HOLE

'

l__J_

0.375" DIAM. HOLE


(TYP.) - (10) TOTAL

0.1875" DIAM. HOLE


(TYP.) - (6) TOTAL

4.5"

6"
FRONT VIEW

TEMPORARY COVER
12-GAGE STAINLESS STEEL

4.5"

!. ___ __j

NEMA 3R AD.JUSTABLE
FLUSH-MOUNT
.JUNCTION BOX
STANDARD PLAN .J-40.37-01
SHEET 2 OF 2 SHEETS

FRONT VIEW

TEMPORARY ACCESS COVER


12-GAGE STAINLESS STEEL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

18-GAGE STAINLESS
STEEL PIANO HINGE
- 1 1/2" OPEN,
1/4" STAINLESS
STEEL BARREL,
1/8" PIN

LENGTH - SEE NOTE 6

NOTES

EQUIPMENT BONDING JUMPER


CONNECTION (BOX) - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

NOT LESS THAN 3"

1. Drilling through reinforcing steel is not allowed. If steel is hit while drilling, the location
shall be moved and the abandoned hole filled with grout conforming to Standard
Specification 6-02.3(20).

PIANO HINGE SEE SECTION B

2. Mount the stainless steel support using an approved resin-bonded anchor system
installed per manufacturer's recommendation. Anchor bolt embedment shall be 4 1/2"
minimum. Resin-bonded anchors shall be stainless steel and shall be 3/8" diameter.
Expansion Anchors are not allowed.

1" (TYP.)

3. There shall be a minimum of 3" edge distance to the centerline of anchor holes in the
concrete.
<0

4. See Standard Plan J-60.13 for Stainless Steel Channel details.

5. The System Identification letters on the box lid shall be 1/8" line thickness formed by

I-

SECTION

w
w

ISOMETRIC VIEW

::c

6. Junction Box shall be dimensioned as shown in the Contract. If the conduit sizes shown

a.

in the Contract are changed, the box dimensions shall be revised in accordance with
NEC 314.28 using the 8 times multiplier for length and width dimensions.

I-

2" (TYP.)

5" MIN. TO 8" MAX.

STAJNLE~

1 518" 1 518"
STEELCHANNELON
STRUCTURE (TYP.)

""---- SYSTEM IDENTIFICATION


- SEE NOTE 5

LOCKNUT - SEAL WITH


BEAD OF SILICONE
CAULK (TYP.)
(SEE NOTE 8)

G-

engraving, stamping, or with a stainless steel weld bead. See System Identification
Detail and Standard Specifications 9-29.2(4).

en
w

EQUIPMENT BONDING JUMPER


CONNECTION (LID) - SEE SINGLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

Cl

7. Equipment Bonding Jumper shall be # 8 AWG (min.)

(TYP.)

conduit connection. An insulated grounded end bushing shall be used to terminate Rigid
Metal Conduit.

9. Junction Box shall be constructed of 12-gage, Type 304 stainless steel with welded seam
construction and # 4 finish. Mounting Flange shall also be 12-gage, Type 304 stainless
steel.

FIELD DRILL 1/2" DIAM. HOLE FOR


RESIN-BONDED ANCHOR BOLT
DRAIN FROM INSIDE TO OUTSIDE ONE SIDE ONLY IN LOWEST CORNER
(TYP.) - SEE NOTE 2
(SEE STANDARD SPECIFICATION 9-29.2(3))

SYSTEM IDENTIFICATION
DETAIL
MOUNTING FLANGE
-SEE NOTE9

- 1" (TYP)

PLAN VIEW
RESIN-BONDED ANCHOR BOLT
- SEE NOTE 2
EQUIPMENT BONDING
JUMPER CONNECTION (LID)
- SEE SINGLE BONDING
JUMPER CONNECTION
DETAIL STANDARD
PLAN J-40.40

<(

LOCKING TAB DETAIL

EQUIPMENT BONDING JUMPER


CONNECTION (BOX) - SEE DOUBLE
BONDING JUMPER CONNECTION
ETAIL STANDARD PLAN J-40.40

~_I
I~ S

112.. (TYP.>

1 5/8" X 1 5/8"
STAINLESS STEEL
CHANNEL (TYP.)

:::: 1" (TYP.)

. I

.1 ~T

SEE NOTE 5

PIANO HINGE SEE SECTION B

a.~

en:::!:

d=
w..,.

NOT LESS THAN 3"

18-GAGE STAINLESS
STEEL PIANO HINGE

LOCKING TAB (TYP.)


SEE DETAILB

3/16" FILLET WELDING BEAD (TYP.)


- BEADING ON EDGE OF MOUNTING
FLANGE IS STAGGERED FROM
BEADING ON EDGE OF BOX

<0

JUNCTION BOX
LID

I
I
I

LOCKING
TAB

I
I
I

D
I

bz
RESIN-BONDED ANCHOR BOLT (TYP.)
- SEE NOTE 2

I I
I

3/8" DIAM. X 1 1/2"


STAINLESS STEEL
BOLT (TYP.)

I
I

<(

a.~

ISOMETRIC VIEW
(MOUNTING STRIP SHOWN)

en
I

1Cl

:5:

I
I

TAPE (4) SPARE 1/4- 20 NC x 1" STAINLESS


STEEL PHILLIPS PAN HEAD SCREWS TO
INSIDE BACK OF BOX

Equipment Grounding Conductor

~ Copper Solderless Crimp Connector


~ Equipment Bonding Jumper -

en:::!:

TOP ENTRY
NEMA 4X SURFACE-MOUNT
~UNCTION BOX
STANDARD PLAN ~-40.38-01

See Note 7

d=
w..,.

NUT- SPOT WELD


(4) PLACES

w
w

::c

1 1/2" CAPTIVE
SCREWBURREND

DETAIL

1 foot of tinned, braided copper.

8. Fittings shall be UL listed and GSA-certified watertight on the outside of the Junction Box

~~==================~~====================~~==========~~====~~

1 1/2" CAPTIVE
SCREWBURR END

DETAIL

SHEET 1 OF 1 SHEET

~ Equipment Bonding Jumper


ELEVATION VIEW
(MOUNTING FLANGE SHOWN)

DRAIN HOLE
(TYP.)

~ See Contract for conduit size


and number

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

NOTES

FIELD DRILL 1/2" DIAM. HOLE FOR


DRAIN TUBE FROM INSIDE TO OUTSIDE ONE SIDE ONLY IN LOWEST CORNER
(SEE STANDARD SPECIFICATION
9-29.2(3)

LOCKNUT- SEAL WITH


BEAD OF SILICONE CAULK
(TYP.) (SEE NOTE 6)

1. Drilling through reinforcing steel is not allowed. If steel is hit while drilling, the location shall be
moved and the abandoned hole filled with grout conforming to Standard Specification 6-02.3(20).
2. Mount the stainless steel support using an approved resin-bonded anchor system, installed per
manufacturer's recommendation. Resin-bonded anchors shall be stainless steel and shall be of
3/8" diameter (Expansion Anchors are not allowed). Anchor bolt embedment shall be 4 1/2" min.
3. There shall be a minimum of 3" edge distance to the centerline of anchor holes in concrete. See
Standard Plan J-60.13 for Stainless Steel Channel details.

RESIN-BONDED ANCHOR
BOLT - SEE NOTE 2

4. The System Identification letters on the box lid shall be 1/8" line thickness formed by engraving,
stamping, or with a stainless steel weld bead. See System Identification Detail and Standard
Specifications 9-29.2(4).

EQUIPMENT BONDING JUMPER


CONNECTION (BOX) - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

5. Junction Box shall be dimensioned as shown in the Contract. If the conduit sizes shown in the
Contract are changed, the box dimensions shall be revised in accordance with NEC 314.28
using the 8 times multiplier for length and width dimensions.

PLAN VIEW

6. Fittings shall be UL listed and GSA-certified watertight on the outside of the Junction Box conduit
connection. An insulated grounded end bushing shall be used to terminate Rigid Metal Conduit.

(DOOR AND WIRING NOT SHOWN FOR CLARITY)

7. Equipment Bonding Jumper shall be# 8 AWG (min.) x 1 foot of tinned, braided copper.
8. Junction Box shall be constructed of 12-gage, Type 304 stainless steel with welded seam
construction and # 4 finish. Mounting Flange shall also be 12-gage, Type 304 stainless steel.

3/16" FILLET WELDING BEAD {TYP.) BEADING ON EDGE OF MOUNTING


FLANGE IS STAGGERED FROM
BEADING ON EDGE OF BOX

DETAIL

WIDTH - SEE NOTE 5

STAINLESS STEEL
CHANNEL {TYP.)

STAINLESS STEEL CHANNEL


MOUNTING DETAIL

1 1/2" CAPTIVE
SCREWBURR END

LOCKING TAB 1" X 1/2" SLOT

18-GAGE STAINLESS STEEL


PIANO HINGE - 1 1/2" OPEN,
1/4" STAINLESS STEEL BARREL,
1/8" PIN

.....

It)

DETAIL

{TYP.)

~-----n
11

LOCKING TAB DETAIL

w
w

en
I

r-1

1 r
rr

rr
rl

''

[i

1-

::c

::

(!)

___________ Jj

18-GAGE STAINLESS
STEEL PIANO HINGE 1 1/2" OPEN, 1/4" STAINLESS
STEEL BARREL, 1/8" PIN

jjj

~
.....

::c

ISOMETRIC VIEW

Equipment Grounding Conductor

(3::>

Copper Solderless Crimp Connector

~ Equipment Bonding Jumper - See note 7


~ Equipment Bonding Jumper shall be a
continuous conductor. Route to each
grounded end bushing and then terminate
at equipment grounding conductor.

EQUIPMENT BONDING JUMPER


CONNECTION (DOOR) - SEE
SINGLE BONDING JUMPER
CONNECTION DETAIL
STANDARD PLAN J-40.40

~ See Contract for conduit size and


number
SYSTEM IDENTIFICATION
DETAIL

1 1/4" X 1/4" CLOSEDCELL NEOPRENE


GASKET

- 1" {TYP)

DETAIL

PIANO HINGE DETAIL

EQUIPMENT BONDING JUMPER


CONNECTION (BOX) - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL STANDARD PLAN J-40.40

SHEET 1 OF 1 SHEET

:::: 1" {TYP.)

. I f- _I
I~

1/2" {TYP.)
FRONT VIEW
(DOOR OPEN TO SHOW WIRE CONNECTION)

FRONT ENTRY
NEMA 4X SURFACE-MOUNT
~UNCTION BOX
STANDARD PLAN ~-40.39-00

-I ~T

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

SEE NOTE 4

0
0:::
L1..

3/8"

>u

<(

en

:;>..:
III

~~

:::!:u
1.0

w
0

1-

w
w
en
N
+

::c

10

0>1-_.
~<(

:::!!:=>
=
0
LOW

'

5" MIN. TO 6" MAX.


5" MIN. TO 6" MAX.
5" MIN. TO 6" MAX.
! EQUALLY SPACED ! EQUALLY SPACED ! EQUALLY SPACED !

1. Junction Box shall be constructed of 12-gage, Type 304


stainless steel with welded seam construction. Mounting Tabs
shall be constructed of 12-gage, Type 304 stainless steel.
Cover shall be constructed of ASTM A 36 steel with slipresistant surfacing.

9/16"

LOCKNUTSEAL WITH BEAD


OF SILICONE CAULK
(TYP.) (SEE NOTE 2)

Ll)

'

'

w
w
en

....1
<(

~ =>

DRAIN TUBESEE NOTE 7

~ ~
....1

:Z

'

3. Equipment Bonding Jumper shall be # 8 AWG (min.)

PLAN VIEW

PLAN VIEW

STAINLESS STEEL
FLAT WASHERS

1/4-20NCx 1"
GROUND LUG

STAINLESS
STEEL NUT

FULL CIRCLE CRIMP


CONNECTOR (TYP.)

STAINLESS STEEL
ADJUSTING NUTS

formed by engraving, stamping, or with a stainless steel weld


bead. See Standard Specification 9-29.2(4).

""C\i
'<t

5. Junction Box shall be dimensioned as shown in the Contract

::c

If the conduit sizes shown in the Contract are changed, the


box dimensions shall be revised in accordance with NEC
314.28 using the 8 times multiplier for length and width
dimension.
Maximum Height = Sidewalk Depth
Maximum Interior Length =29"
Maximum Interior Width = 18"

10

1/4- 20 NC x 1" STAINLESS


;

_p

1/4-20NCx1"
GROUND LUG

a.:
~

6. See Standard Plan J-40.36 for additional requirements.


7. Field drill 1/2" diameter hole for Drain Tube from the inside to

1/4-20 x 1" STAINLESS STEEL PHILLIPS


COUNTERSUNK SCREW (TYP.)- LIBERALLy
COATED WITH ANTI-SEIZE COMPOUND

\1

10. Liberally coat the threads of the cover fasteners


with anti-seize compound during construction
and before final closure.

_~
~
1.0

FLAT STEEL COVER WITH


SLIP-RESISTANT SURFACNG
(ASTM A 36)

"

' .

" I v.

1/4-20 NC x 1" STAINLESS STEEL


WELL NUT WITH A DAM AT THE REAR TO
PREVENT CONCRETE INFILTRATIONTACK WELD NUT IN (3) PLACES

NEOPRENE
GASKET

'

FLUSH WITH SIDEWALK

1/4" X 20 NC X 1"
STAINLESS STEEL
SEALED NUT
1.0

1.0

10

w
w

en

~--~~~~=T--~~~~~==~
en

0.5" DIAM
HOLE (TYP.)

:
v

DETAIL
NEOPRENE
GASKET

.
. 'l

"

9. Conduits shall enter through the sides as shown.


Conduits shall not enter through the bottom of
Junction Box.

' v

::c
~

__l

Iv

EQUIPMENT BONDING JUMPER


CONNECTION - SEE SINGLE BONDING
JUMPER CONNECTION DETAIL

SIDEWALK
(

...
1 1/4" x1/4" CLOSED-CELL
NEOPRENE GASKET

8. Conduit capacity is 12"- 4" per side.

109"

~ Equipment Bonding
'V" Jumper

See Contract for conduit


~ size and number

'

A Equipment Bonding
'::Y Jumper - See note 3

DOUBLE BONDING JUMPER


CONNECTION DETAIL

1/16"

3/8" FLAT STEEL COVER


WITH SLIP-RESISTANT

Copper Solderless
Crimp Connector

the outside of Junction Box. One place, on the lowest side


only. Seal with bead of silicone. See Standard Specification
9-29.2(3). For drain tube routing, see Standard Plan J-50.16.

./.0.. Equipment Grounding

"V" Conductor

FULL CIRCLE CRIMP


CONNECTOR (TYP.)

SINGLE BONDING JUMPER


CONNECTION DETAIL

STEEL PHILLIP. S COUNTERSUNK '


SCREW (TYP.)

JUNCTION
BOX WALL

3 feet

4. The System Identification letters shall be 1/8" line thickness

minimum of tinned, braided copper.

--------

JUNCTION BOX COVER

::c

1 1/2" X 1 1/2" X 1 1/2" X 12-GAGE


MOUNTING TAB (TYP.)

5
WIDTH - SEE NOTE 5

DRAIN TUBESEE NOTE 7

<(

the outside of the Junction Box connection. Use an insulated,


grounded end bushing on the inside for Rigid Metal Conduit.

1.0

:::!!: =>
0
i"rl w
@

:::!!: =>
0
in w

w
w
en

<(

Co en

- SEE NOTE 4

'

0
i"rl w

10

I'

w
10

~ uitw

::c

<o a.
en

Co en
~ ~
....1

2. Fittings shall be UL listed and GSA-certified concrete tight on

w
0

\ _ SYST:EM IDENTIFICATION

:::!!:

1-

r------- ----l:.-"f----~-------

9/16"

3/8"

'

~ w
:::!!: u
<(
:Z

I
I

'

. ....1

1-

5" MIN. TO 6" MAX.


EQUALLy SPACED

'

I
I

= it
co
en

5" MIN. TO 6" MAX.


EQUALLy SPACED

r-------r------r-----.

::::i

5" MIN. TO 6" MAX.


EQUALLy SPACED

NOTES

LENGTH + 2.343" - SEE NOTE 5

LENGTH + 2" - SEE NOTE 5

SIDE VIEW

1-

a.
w

EQUIPMENT BONDING JUMPER


CONNECTION - SEE DOUBLE
BONDING JUMPER CONNECTION
DETAIL

LENGTH - SEE NOTE 5

DRAIN TUBESEE NOTE 7

TAPE (4) SPARE 1/4- 20 x 1" STAINLESS


STEEL PHILLIPS COUNTERSUNK
SCREWS TO INSIDE OF BOX

SYSTEM IDENTIFICATION
DETAIL
- 1" (TYP)

. I

~
I~ S

1/2" (TYP.)
SEE NOTE 4

ELEVATION VIEW

NEMA 4X JUNCTION BOX


IN SIDEWALK LOCATED
ON STRUCTURE
STANDARD PLAN J-40.40-00
SHEET 1 OF 1 SHEET

:::: 1" (TYP.)

___[

-II-T

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

______

-------s=T=M=E=DE=si=GN~E~NG=IN=E-ER

5120113
DATE

. . . Washington State Department of Transportation

DETAIL"A"
SEE STANDARD PLAN J-50.15
SHEET 2

CHISEL OUT 1/8" TO 1/2" CORNER


REMOVE PAVEMENT TO SAWCUT DEPTH AND FILL
WITH SEALANT (TYP.)

CHISEL OUT 1/8" TO 1/2" CORNER


REMOVE PAVEMENT TO SAWCUT DEPTH AND FILL
WITH SEALANT

SHOULDER

SEE ENTRANCE
SAWCUT DETAIL
THIS SHEET (TYP.)

SEE CORNER SAWCUT


DETAIL (TYP.)

~~~~~~~~~~~~~~~~~~~~~~~~~~~]~-- -~- --~--!


3'- 0"

(TYP.)

LOOP SAWCUT
w

------------- ~ ~

w 0.:

~ ~

T- SAWCUT DETAIL

I;:: Cl

CORNER SAWCUT DETAIL

....1
....1

----------------~-----

Cl
Cl

c:::
w

LL.

TYPE 1 INDUCTION LOOP

STOP LINE

::J

LEAD-IN
SAWCUTS (TYP.)

....._----lr-t-t----------------------------l-----------.-----------.----- (.)~
:c

------------- ~ ~

LANE NUMBER

LOOP NUMBER

LOOP NUMBER MARKING DETAIL

SEE T- SAWCUT DETAIL

=-_jl

PHASE NUMBER

NOTES
1. For Installation Notes and Details
see Standard Plan J-50.15.

TYPE 1 STOP LINE LOOPS


(40' LONG OR AS SHOWN IN THE CONTRACT)

PLAN

2. For Sections A, B, C, and D,


see Standard Plan J-50.15.

TYPE 1 STOP LINE LOOPS

2C(SH)CABLE

JUNCTION BOX
S =START
F =FINISH

LOOP NUMBER
MARKING SLEEVE

LOOP SERIES START OR


FINISH MARKING SLEEVE

STOP LINE

LEAD-IN SAWCUT

. - TRAFFIC FLOW
LOOP SAWCUT

CHISEL OUT 1/8" TO 1/2" CORNER


REMOVE PAVEMENT TO SAWCUT DEPTH AND FILL
WITH SEALANT (TYP.)
CENTER OF LOOP
AND VEHICLE LANE

TYPE 1 INDUCTION LOOP


2'- 0"

STANDARD PLAN .J-50.10-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


----~~~~~----

.....

TYPE 1 STOP LINE LOOP WIRING DIAGRAM

ENTRANCE SAWCUT DETAIL

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

DETAIL "A"
SEE STANDARD PLAN J-50.15
SHEET 2

CHISEL OUT 1/8" TO 1/2" CORNER


REMOVE PAVEMENT TO
SAWCUT DEPTH AND
FILL WITH SEALANT

EDGE OF SHOULDER

LOOP SAWCUT

r---~--------~~----~~------~-----

----

....1
....1

Cl
Cl

~-- -~1i-----------~

0::

z
------ ::::i
a.

LL.

l-

::::i

>

~~

SEE ENTRANCE
SAWCUT DETAIL
(TYP.)

CORNER SAWCUT DETAIL

'1---"'------'

-------------------- ----------

SEE CORNER
SAWCUT
DETAIL (TYP.)

en

-=t3'
-0"
-=_}-~~-------~ ~

3'-0"

EDGE OF LANE

------- ---------------------------- ....1


w

:cw

Cl

>

1'- 0"
6'- 0"

NOTES

SEE CORNER
SAWCUT DETAIL
(TYP.)

For Installation Notes and Details


see Standard Plan J-50.15.
6'- 0"

6'- 0"

8'- 0"

8'- 0"

6'- 0"

2.

STATION#
SEE CONTRACT

TYPE 2 STOP LINE LOOPS

PLAN

For Sections A, B, C, and D,


see Standard Plan J-50.15.

3. All of the loop lead-in wires shall


return to the Junction Box.

TYPE 2 ADVANCE LOOPS

DETAIL "A"
SEE STANDARD PLAN J-50.15
SHEET 2

4.

For Splice Detail, see


Standard Plan J-50.15.

5.

For additional Induction Loop details,


see Standard Plan J-50.15.

SHOULDER

EDGE OF SHOULDER

LEAD-IN SAWCUT
EDGE OF LANE

3'-0"

w
(TYP.)
~
____ w
--~~
3'- 0"
(TYP.)

SEE ENTRANCE SAWCUT


DETAIL - SHEET 1

LOOP SAWCUT

aJ

>

CHISEL OUT 1/8" TO 1/2" CORNER


REMOVE PAVEMENT TO SAWCUT DEPTH AND FILL
WITH SEALANT (TYP.)
CENTER OF LOOP
AND VEHICLE LANE

------d

SEE CORNER SAWCUT


DETAIL - SHEET 1

--~~

2'- 0"

:c

TYPE 2 INDUCTION LOOP


STANDARD PLAN .J-50.11-00

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION
6'- 0"

8'- 0"

Pasco Bakotich Ill

6'- 0"

TYPE 2 SAMPLING LOOPS

ENTRANCE SAWCUT DETAIL

......
fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

SEE LOOP NUMBERING


LAYOUT DETAIL
2C(SH) CABLE

S =START
F =FINISH

....1
....1

0
0

LOOP SERIES NUMBER


MARKING SLEEVE (TYP.

::::i

0:::

w
u.

..,. TRAFFIC FLOW

SPLICE (TYP.)

LOOP SERIES START


OR FINISH MARKING
SLEEVE (TYP.)

LOOP SERIES
NUMBER (TYP.)

LOOP NUMBERING LAYOUT DETAIL


w

::::i

a.

f2
en

3
L
PHASE NUMBER
LANE NUMBER

=-_jl

LOOP NUMBER

LOOP NUMBER MARKING DETAIL

TYPE 2 STOP LINE LOOP WIRING DIAGRAM


SERIES SPLICE SHOWN
SPLICE

2C(SH) CABLE

------,

v-

JUNCTION
BOX

-------------~
I

I
I

1
..... _________

JUNCTION
BOX

I
I
I
I
I
I

S11J
__

..,. TRAFFIC FLOW

..,. TRAFFIC FLOW

LOOP SERIES
NUMBER (TYP.)

LOOP SERIES
NUMBER

TYPE 2 INDUCTION LOOP

STANDARD PLAN .J-50.11-00


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

TYPE 2 SAMPLING LOOP WIRING DIAGRAM


SERIES SPLICE SHOWN

TYPE 2 ADVANCE LOOP WIRING DIAGRAM

.....
fll

----=sr=Ar=E=oE=SIG=N:-=EN""G=INE=ER,....---

06-03-11
DATE

Washington State Department of Transportation

DETAIL"A"
SEE STANDARD PLAN J-50.15
SHEET 2

EDGE OF SHOULDER

....1
....1

Cl
Cl

SEE ENTRANCE
SAWCUT DETAIL
THIS SHEET TYP.

::::i

0::

EDGE OF LANE

SHOULDER - - ...

LL

SEE ENTRANCE
SAWCUT DETAIL
THIS SHEET (TYP.)

Cl

::::i
~
0

CIRCULAR SAWCUT (TYP.)

--------- --------------- ---

NOTES

l-

en

-------------------~~ -~~---------------Z~

6'- 0" DIAM. (TYP.)

6' - 0" DIAM. (TYP.)

CIRCULAR SAWCUT
(TYP.)

6'- 0"

8'- 0"

6'- 0"

8'- 0"

For Installation Notes and Details


see Standard Plan J-50.15.

2.

For Sections A, B, C, and D,


see Standard Plan J-50.15.

3.

All of the loop lead-in wires shall


return to the Junction Box.

4.

For Splice Detail, see


Standard Plan J-50.15.

5.

For Loop numbering Layout Details,


see sheet 3.

6.

For additional Induction Loop Details,


see Standard Plan J-50.15.

6'- 0"

6'- 0"

STATION#

SEE CONTRACT

PLAN

TYPE 3 STOP LINE LOOPS

TYPE 3 ADVANCE LOOPS

JUNCTION
BOX
DETAIL "A"
SEE STANDARD PLAN J-50.15
SHEET 2
EDGE OF LANE

EDGE OF SHOULDER

CIRCULAR SAWCUT
(TYP.)

LEAD-IN SAWCUT

---11~---

---~li_____________ _

LOOP SAWCUT

LEAD-IN
SAWCUT

z~

CENTER OF LOOP AND


VEHICLE LANE

6' - 0" DIAM. (TYP.)

2'- 0"

TYPE 3 INDUCTION LOOP


STANDARD PLAN J-50.12-00
SHEET 1 OF 3 SHEETS

6'- 0"

8'- 0"

APPROVED FOR PUBLICATION

6'- 0"

Pasco Bakotich Ill


------~~~~==-------

PLAN

TYPE 3 SAMPLING LOOPS

.....

ENTRANCE SAWCUT DETAIL

STATE DESIGN ENGINEER

06-03-11
DATE

fll Washington State Department of Transportation

OF~~~~~~~~~

-----

_L ~~~c:~oN

~==~~=============~~~~

...J
...J

Box

~~~~~~~-

Cl
Cl

::J

2C(SH) CABLE

0:::

w
u...

L
PHASE NUMBER
LOOP SERIES
NUMBER (TYP.)

LANE NUMBER

=-_jl

LOOP NUMBER

LOOP NUMBER MARKING DETAIL


w

NOTES

::J
ll.

Loop numbering layout will be simillar to Loop


Numbering Layout Detail, Sheet 3

en

ce

SPLICE (TYP.)
OFFSET CRIMPS

TRAFFIC FLOW

---L

-J~~~TION BOX
: S =START
I F =FINISH
I
I

2C(SH) CABLE

TYPE 3 STOP LINE LOOP WIRING DIAGRAM

S11

__ J

SERIES SPLICE SHOWN

SPLICE (TYP.)
OFFSET CRIMPS

----

JUNCTION BOX
SPLICE

---- --1
I

: S =START
2C(SH) CABLE

: F =FINISH

-ce TRAFFIC FLOW

I
I
I
1
S2

--"
LOOP SERIES
NUMBER

TYPE 3 ADVANCE
LOOP WIRING DIAGRAM

TYPE 3 INDUCTION LOOP


-ce TRAFFIC FLOW

STANDARD PLAN .J-50.12-00


SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

TYPE 3 SAMPLING LOOP WIRING DIAGRAM


SERIES SPLICE SHOWN

Pasco Bakotich Ill


- .------=sr=A=TE'""oE=s=IGN""'E,_:NG"'""IN:,EE..:._R..:..:..:___
....

06-03-11
DATE

fll Washington State Department of Transportation

DETAIL"B"
SEE STANDARD PLAN J-50.15
SHEET 2
....1
....1

EDGE OF SHOULDER

0
0
::J

,..___ _ SHOULDER

0:::

LL.

---

3'-0"

!;!E

(TYP.)

::5

S =START

LOOP NUMBER
MARKING SLEEVE

-~~-;---i

F =FINISH

>

::J

a.

~
(/)

6' 0" DIAM.


(TYP.)

::s
w

--------..:.~

(.)

w
Z(.)-1

::s

:E

LOOP SERIES NUMBER


MARKING SLEEVE (TYP.)

>

CIRCULAR SAWCUT
(TYP.)

6'- 0"

8'- 0"

6'- 0"

8'- 0"

6'- 0"

8'- 0"

6'- 0"

LOOP SERIES START OR FINISH


MARKING SLEEVE (TYP.)

LOOP NUMBERING LAYOUT DETAIL

PLAN

TYPE 3A STOP LINE LOOPS

r- --------------

L X X X
PHASE NUMBER

JUNCTION BOX
LANE NUMBER

=-_jl

LOOP NUMBER

LOOP NUMBER MARKING DETAIL

----~

--~~~Sx~>c>c~x=~~~~>~CX~~~=x~

2C(SH) CABLE

LOOP SERIES
NUMBER

::J

a.

TYPE 3 INDUCTION LOOP

STANDARD PLAN .J-50.12-00


SHEET 3 OF 3 SHEETS

c TRAFFIC FLOW

APPROVED FOR PUBLICATION

TYPE 3A STOP LINE LOOP WIRING DIAGRAM


SERIES SPLICE SHOWN

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

LOOP SEALANT
(PER CONTRACT OR
AS APPROVED BY
THE ENGINEER)

LOOP SEALANT
(PER CONTRACT OR
AS APPROVED BY
THE ENGINEER)

TOP OF EXISTING
PAVEMENT OR
LEVELING COURSE
OF NEW PAVEMENT

NOTES

LOOP SEALANT
(PER CONTRACT OR
AS APPROVED BY
THE ENGINEER)

TOP OF EXISTING PAVEMENT


OR LEVELING COURSE
OF NEW PAVEMENT

1. Fill the conduit trench to the bottom of the existing


or new surfacing with CSTC, sand or controlled
density fill. See Standard Specifications
Section 2-09.3(1)E.
2.

I:::J

{)

~
en

u.
0

c.,
I

::c ~

li:w ~
Cl

I:::J

0::

0 w
~
<( 0::
::c {)
a. z
0
en
<( {)
u. I0 z
::c w
I- :::2:
w
a. {)
w

tu

{)

~
en

u.
0

c.,
I

::c ~

li:w ~
Cl

Cl

0::

0 w
~
<( 0::
::c {)
a. z
0
en
<( {)
u. I0 z
::c w
I- :::2:
w
a. {)
w

tu

o::

~~

~c.,

~w
<(0::

0:::2:

en!
u.

0~
::c:::2:
I-

fu~

ON

Cl

1!:

Minor Regional variations are allowed in the soft


pocket closure. Consult with the Engineer or see
the Contract for additional requirements.

~ 3. Conductors shall be snug to the bottom of the

sawcut. High temperature backer rod shall be


snug to the conductors and sides of cut.

u. 1-

oz

::cW
~
w u

li:

4.

Cl

Fill the sealant to within 1/8" to 3/16" from top of


saw cut.

5. See Standard Plan J-40.1 0 for additional Junction


Box details.

PVC CONDUIT SIZING TABLE

SECTION

SECTION

SECTION

LOOP LEAD PAIRS

1-4

5- 10 11 - 16 17- 22 23- 28

NUMBER AND SIZE


OF CONDUITS

1 - 2"

2 - 2"

3 - 2"

4 - 2"

3 - 3"

/.0.. ADD 1/16" TO THE SAWCUT

~ FORIMSA51-7CONDUCTORS

MATCH EXISTING

EDGE OF PAVED SHOULDER (SHOWN)


OR EDGE OF EXTRUDED CURB
OR EDGE OF GUTTER PAN
OR EDGE OF TRAFFIC BARRIER

SAWCUT EXISTING
PAVEMENT{BOTH
SIDES OF TRENCH)

STANDARD JUNCTION
BOX

TOP OF EXISTING
PAVEMENT OR
LEVELING COURSE
OF NEW PAVEMENT

FULL DEPTH
SAWCUT

LOOP LEAD -IN WIRES


-TWISTED PAIR

ADD 1/8" TO THE SAWCUT


~ FORIMSA51-7CONDUCTORS

PAVING MATERIAL

1' - 0" APPROX.

TRENCH WIDTH -SEE


STD. SPEC. 8-20.3(5)

LOOP STUB-OUT SLEEVE (1/4" to 1/2"


BELOW TOP OF ASPHALT)
LOOP LEAD-IN SAWCUT
2 5/8" MIN. - 3" MAX.
LOOP LEAD-IN WIRES
-TWISTED PAIR
EXISTING
PAVEMENT

w
:::2: {)
<(
0 u.

....'

CONDUIT END BELL


BUSHING, SEAL WITH
DUCT SEAL

0:: 0::
u. :::J

DETECTOR LEAD-IN
2C(SH) CABLE

:::2:

en

:::J Cl

:::!!: w

z ~
~ a.

CSTC,SAND
OR CONTROLLED
DENSITY FILL

CSTC,SAND
OR CONTROLLED
DENSITY FILL

u.
b 0
' a.
N 0

GRAVEL PAD

I-

LEAD-IN
CONDUIT

SEE PVC CONDUIT


SIZING TABLE

CONDUIT
TO LOOP

50' MAXIMUM DISTANCE


SEE STUB-OUT CONDUIT PLACEMENT DETAILS

STANDARD PLAN .J-50.15-00


SHEET 1 OF 3 SHEETS

JUNCTION BOX PLACEMENT


SECTION

INDUCTION LOOP DETAILS

SEE NOTES

SECTION

LEAD-IN CONDUIT SECTION

MAX. 50 FT POCKET SECTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

LOOP INSTALLATION NOTES


SPLICE PER STD. SPECS 9-29.12{2)
FOIL SHIELD

1. Install the Junction Box and the stub-out conduit with PVC sleeve.
Conduit for the loop stub-out shall be as required in the conduit
size table shown on sheet 1 of this set.

PLASTIC MOLD OR HEAT


SHRINK TAPE
SOLDERED COMPRESSION CONNECTION
-OFFSET FROM EACH OTHER (TYP.)

*DRAIN WIRE

2. Lay out loops and loop lead-ins to miss cracks/joints in road,


when possible. Maintain 18" minimum clearance from manholes
and valve boxes.

WIRE
FROM LOOP

3. The opening around the loop stub shall be patched with matching
paving material if opened larger than PVC sleeve+ 2".

WIRE
TO LOOP
*

GROUND DRAIN WIRE


AT CONTROLLER
CABINET ONLY

1"

4. Sawcut the loop slots and the lead-in slots. Wash/dry cuts. File
edges to remove burr of all saw-cuts into stub out sleeve.

TWO LAYERS VINYL


ELECTRICAL TAPE
(TYP.)

1"

5. Lay out the loop wire starting at the Junction Box, allowing 5'
minimum slack.

SPLICE DETAIL

6. Install the wire in the loop slot as shown.


7.

8. Twist each pair of the lead-in wires a minimum of two times per foot
each foot, from the loop to the Junction Box. Reverse the direction
of the twist for each successive pair installed. Sealloops/sawcuts.

SEE STUB-OUT CONDUIT


PLACEMENT DETAILS, SHEET 3

LOOP STUB-OUT SLEEVE


SEE NOTE 14

SEE STUB-OUT CONDUIT


PLACEMENT DETAILS, SHEET 3
12" APPROX.

Finish laying out the wire at the Junction Box and identify the leads
with the loop number, the "S" for start and the "F" for the finish,
the loop series number, and the loop lead-in conductor number.

DETAIL "A"

9. Construct a supplemental splice containing any series loop connections in the adjacent junction box as required in the plans. Supplemental
splices are subject to the same requirements shown for the loop lead-in
and the shielded cable splice.
10. Splice the loop lead-ins to the shielded cable as noted in the Contract.

FILL WITH SEALANT


(PER CONTRACT OR AS
APPROVED BY THE
ENGINEER)

CONDUIT\

11. All loop circuits shall be tested per Standard Specifications


8-20.3(14)D once installation is complete.

1/2" SAWCUTS
LEAD-IN
SAWCUTSAS REQUIRED

1/2" SAWCUT

12.

TO LOOPS-~-------~---------~~~~~~~~~~~~~~~r.~~
9-~~=*==========~::::::::t

>-'
~-------------------TO JUNCTION BOX

EDGE OF PAVED SHOULDER,


OR BARRIER, OR EDGE
OF GUTTER PAN

13. All loop lead-in sawcuts parallel to lane edge shall


be at least 12" from edge of pavement and within
six inches outside of lane or fog line when
possible. Maintain 12" separation
between parallel cuts or joints.

SAW CUT EXISTING PAVEMENT


(WIDTH EQUAL TO STUBOUT
SLEEVE DIAMETER PLUS 2")
~
Co

s--1

MATCH EXISTING
PAVING MATERIAL

Existing stubouts shall be upgraded as necessary to conform


to the conduit size table shown on sheet 1.

14. The loop stub-out sleeve shall have


an inside diameter 1" larger than
the outside diameter of the
End Bell Bushing. Plug conduit
and fill sleeve with sand untill
loops are installed to keep
out Hot Asphalt during
paving operations.

SOFT POCKET (WIDTH EQUAL TO


STUBOUT SLEEVE DIAMETER PLUS 2")
CONDUIT OR
END BELL BUSHING

PLAN
SAWCUT AND CONDUIT CONNECTION

INDUCTION LOOP DETAILS


SEE STUB-OUT CONDUIT
PLACEMENT DETAILS, SHEET 3

STANDARD PLAN .J-50.15-00


SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

DETAIL "B"

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

GUARDRAIL WITH POST


AND BLOCK
CEMENT CONCRETE CURB OR GUTTER
SEE STANDARD PLAN F-10.12

SIDEWALK

"

12"

LOOP STUB-OUT SLEEVE (1/4" TO 1/2"


BELOW TOP OF PAVEMENT)

t>'

1:>
1:>
>.

CEMENT CONCRETE CURB OR GUTTER


SEE STANDARD PLAN F-10.12
12"

...... .. ..1

1:>

LOOP STUB-OUT SLEEVE (1/4" TO 1/2"


BELOW TOP OF PAVEMENT)

t>'

1:>

LEAD-IN CONDUIT SHALL EXTEND A


MINIMUM OF 3/4" INTO PAVEMENT
(PAVEMENT DEPTH VARIES)

LEAD-IN CONDUIT SHALL EXTEND A


MINIMUM OF 3/4" INTO PAVEMENT
(PAVEMENT DEPTH VARIES)

CONDUIT SECURED INTO


ROAD SURFACE (TYP.)

:Z

v z
N:::i:

v
N:::i:

TO JUNCTION BOX ~

TO JUNCTION BOX , . . - - - - - - - L - - - - - - - "

===

...L..__

CONDUIT SECURED INTO


ROAD SURFACE (TYP.)

_L__ _ _ __ ,

STUB-OUT DETAIL
WITH CEMENT CONCRETE CURB OR GUTTER

STUB-OUT DETAIL
WITH GUARDRAIL AND CURB

CEMENT CONCRETE BARRIERSINGLE SLOPE BARRIER SHOWN


SEE CONTRACT PLANS FOR
SIZE AND TYPE

LOOP STUB-OUT SLEEVE (1/4" TO 1/2"


BELOW TOP OF PAVEMENT}

LEAD-IN CONDUIT SHALL EXTEND A


MINIMUM OF 3/4" INTO PAVEMENT
(PAVEMENT DEPTH VARIES)

v :Z
N:::i:

CONDUIT SECURED INTO


ROAD SURFACE (TYP.)

LEAD-IN CONDUIT SHALL EXTEND A


MINIMUM OF 3/4" INTO PAVEMENT
(PAVEMENT DEPTH VARIES)

vz
N:::i:

CONDUIT SECURED INTO


ROAD SURFACE (TYP.)

INDUCTION LOOP DETAILS


STANDARD PLAN .J-50.15-00
SHEET 3 OF 3 SHEETS

TO JUNCTION BOX , . - - - - - - - ' - - - - - -

APPROVED FOR PUBLICATION

TO JUNCTION BOX , . - - - - - - - ' - - - - - - -

Pasco Bakotich Ill

STUB-OUT DETAIL
WITH ROADWAY

STUBOUT CONDUIT PLACEMENT DETAILS

STUB-OUT DETAIL WITH


CEMENT CONCRETE BARRIER

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

INDUCTION LOOP LEAD-IN


TO JUNCTION BOX

S =START
F =FINISH

PREFORMED INDUCTION LOOP


LEAD-IN TO JUNCTION BOX

NOTES

51

~---------.--

F1

1. Installation of signal detection loops in the bridge deck shall be cast-in-place and
installation by saw cutting an existing bridge deck shall not be allowed. This plan
is intented for new construction only (not allowed for existing structures).

SECURE GEL FILLED SPLICE BOX


BETWEEN TRANSVERSE REBAR
(TYPICAL)

LOOP SERIES NUMBER

2. For Supplemental Splice in adjacent junction box, see Splice Detail,


per Standard Plan J-50.15.
3. Preformed loops shall conform to the layouts, numbering details, marking requirements, and wiring diagrams of Standard Plan J-50.12 for the number and types
of loops shown in the Contract Plans.
~

TRANSVERSE
REBAR

4. Loops shall be tested immediately prior to pouring concrete, per Standard


Specification 8-20.3(14)D.
5. Layout Preformed loops and loop lead-ins to maintain 1' (ft.) clearance from joints.

LONGITUDINAL
REBAR

6. Construct a supplemental splice containing any series loop connections in adjacent


Junction Box as required in the Plans. Supplemental splices are subject to the same
requirements shown for the loop lead-in and the shielded cable splice, as shown in
Standard Plan J-50.12.

SECURE GEL FILLED SPLICE BOX


BETWEEN TRANSVERSE REBAR (TYPICAL)

7. Barrier Junction Box- 8" x 8" x 18" NEMA 4X in stationary-form barrier, adjustable
NEMA 3R in slip-form barrier. (Junction Box can be recessed up to 1/8".) See
Standard Plan J-40.36 or J-40.37.

en

8. For installation of Junction Box in the sidewalk, see Standard Plan J-40.40.

w
r::r::
w

ID
...J
...J

SELF-LOCKING TIE - NYLON 6/6


(MIN. GRADE) 120# MIN. TENSILE
STRENGTH, UV STABILIZED (TYPICAL)

iii

TRANSVERSE REBAR

Cl
~

INDUCTION LOOP LEAD-IN


TO JUNCTION BOX

ROUTE LEAD-IN BETWEEN TOP


AND BOTTOM REBAR MATS

LONGITUDINAL REBAR

SECURE PREFORMED INDUCTION


LOOP TO THE REBAR AT
APPROXIMATELY 2' (FT.)
INTERVALS (TYP.)

LOOP LEAD-IN TO
JUNCTION BOX

PLAN VIEW

S =START
F =FINISH

~==~

LONGITUDINAL
REBAR

51

.1'-

"

'-.....

F1

---

--

LOOP SERIES NUMBER

'

1/
/
IF

"

'\

,
/

'

INDUCTION LOOP LEAD-IN


TO JUNCTION BOX

SECURE GEL FILLED SPLICE BOX


BETWEEN TRANSVERSE REBAR
(TYPICAL)

TRANSVERSE
REBAR

----

SECURE PREFORMED INDUCTION LOOP


TO THE REBAR AT APPROX. 2' (FT.)
INTERVALS (TYPICAL)

/
...___

--- ---

PLAN VIEW

-----

ELEVATION VIEW

6' (FT.) DIAMETER PREFORMED INDUCTION


LOOP, 3/8" (IN.) MAXIMUM OUTSIDE DIAMETER
CABLE. 4 TURNS PER PREFORMED
INDUCTION LOOP

" _,

1'\

WIRING DIAGRAM FOR


PREFORMED INDUCTION LOOP

SECURE SPLICE BOX BETWEEN


TRANSVERSE REBAR

6' (FT.) DIAMETER PREFORMED


INDUCTION LOOP, 3/8" (IN.)
MAXIMUM OUTSIDE DIAMETER
CABLE. 4 TURNS PER PREFORMED
INDUCTION LOOP
SECURE PREFORMED INDUCTION
LOOP TO THE REBAR AT APPROX.
2' (FT.) INTERVALS (TYPICAL)

WIRING DIAGRAM FOR


PREFORMED INDUCTION LOOP
2-LOOP ARRAY

TOP OF BRIDGE DECK


OR APPROACH SLAB

PREFORMED LOOP
INSTALLATION DETAILS
FOR NEW BRIDGE DECKS
STANDARD PLAN .J-50.16-01
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

3122113
DATE

. . . Washington State Department of Transportation

NEMA JUNCTION BOX IN SIDEWALK WITH SLIP


RESISTANT LID - SEE STANDARD PLAN J-40.40
SEE CONTRACT DOCUMENTS FOR SIZE

2" CONDUIT
IN SIDEWALK

CURB

2-2" CONDUITS
IN BARRIER

TOP OF BARRIER

8" X 8" X 18"


NEMA JUNCTION BOX
IN BARRIER - SEE
STANDARD PLAN J-40.36

8" X 8" X 18" NEMA JUNCTION


BOX IN BARRIER

2" CONDUIT
IN BARRIER

LOOP LEAD-IN
(2 MAX PER
1" CONDUIT)

2" CONDUIT

--~~--~~~L---------~----~~~INBARRIER
2" CONDUIT
IN BARRIER

TOP OF BRIDGE DECK

2" CONDUIT
IN SIDEWALK

2-2" CONDUITS
IN BARRIER

PLAN VIEW
1" CONDUIT
8" X 8" X 18" NEMA JUNCTION
BOX IN BARRIER
NEMA JUNCTION BOX IN SIDEWALK WITH SLIP
RESISTANT LID- SEE STANDARD PLAN J-40.40
SEE CONTRACT DOCUMENTS FOR SIZE

en

1" CONDUIT

ID

SECTION
SIDEWALK

2" CONDUIT
IN BARRIER

1" CONDUIT

BOTTOM OF
BRIDGE DECK

DRAIN TUBE

1" CONDUIT

w
r::r::
w

LOOP LEAD-IN
(2 MAX PER 1" CONDUIT)

ELEVATION VIEW

SINGLE SLOPE TRAFFIC BARRIER

TOP OF BRIDGE DECK

...J
...J

iii

DRAIN TUBE

j_~~~~~~

q-

LOOP LEAD-IN
(2 MAX PER 1" CONDUIT)

2" CONDUIT IN SIDEWALK


DRAIN TUBE

RUN CONDUIT AND LOOP LEAD-INS


BETWEEN TOP AND BOTTOM REBAR MATS

SECTION

PEDESTRIAN BARRIER

TOP OF BARRIER

8" X 8" X 18" NEMA JUNCTION


BOX IN BARRIER

2" CONDUIT
IN BARRIER
8" X 8" X 18" NEMA JUNCTION
BOX IN BARRIER

2" CONDUIT
IN BARRIER

TOP OF BRIDGE DECK

SIDEWALK
TOP OF BRIDGE DECK

DRAIN TUBE

1" CONDUIT
1" CONDUIT

LOOP LEAD-IN
(2 MAX PER 1" CONDUIT)

BOTTOM OF
BRIDGE DECK

DRAIN TUBE

SECTION

1" CONDUIT

BOTTOM OF
BRIDGE DECK

PREFORMED LOOP
INSTALLATION DETAILS
FOR NEW BRIDGE DECKS
STANDARD PLAN .J-50.16-01
SHEET 2 OF 2 SHEETS

ELEVATION VIEW

APPROVED FOR PUBLICATION

PEDESTRIAN BARRIER

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

3122113
DATE

. . . Washington State Department of Transportation

NOTES
....1
....1

Cl
Cl

::::i

EDGE OF SHOULDER \

-------------~----------------------------------------------------------------------------

16'- 0"

0::

EDGE OF LANE

=r
"~

ADVANCED INDUCTION LOOP


MODIFIED TYPE 2 (TYP.)
-SEE NOTE 3

CX)c_

-' ~

Cl

LANE2

L4

1. See Standard Plan J-50.30 for Piezo axle sensor General Installation instructions, and Modified
Type 2 Loop wiring details.
2. The contractor shall notify the Statewide Travel and Collision Data Office (STCDO) (formerlyTDO)
a minimum of five working days prior to the scheduled site installation. An inspector from the WSDOT
STCDO shall be on site for all phases of installation.

PIEZO AXLE SENSOR


(CLASS 2) (TYP.)

LL.

DECREASING MILEPOST
DIRECTION

3. The loop inductance of two loops within the same lane shall be within 20 micro henries of each other.
all piezo ohms readings shall be 0\L from shield to center conductor. See piezo specifications
for piezo capacitance readings.

LANE

LIN~

4. The loops and axle sensors shall be cut in the final lift of asphalt after lane striping is completed.
All PTR loops shall be spaced @16ft. leading edge to leading edge.
5.

SEE LOOP SAWCUT DETAIL


-THIS SHEET

~~

LANE 1

For concrete pavement lanes with asphalt shoulders, install all of the piezo sensors and splices
in the concrete lane. Also, for concrete lanes, install the loops 4" and 6" away from the
expansion joints.

6. The shoulder notch length along the roadway shall be 4" or the conduit diameter plus 2" or
whichever is larger. The shoulder notch width perpendicular to the roadway shall be the
conduit size plus 1/4".

L----L-1---1

7. After all sensor leads are installed, seal the end of the conduit with conduit sealant. Use asphalt
cold-patch to fill notch unless otherwise specified in the contract.

INDUCTION LOOP I PIEZO AXLE SENSOR


NUMBER IDENTIFICATION

(6 ft Class II Piezos)

CABINET
SEE NOTE 8

100ft Coax

5nf +

150ft Coax

6nf +

Lane 2- (pass lane) - Loop L3, Piezo P2, Loop L4

200ft Coax

7nf +

250ft Coax

8nf +

PLAN VIEW

TYPICAL 2 LANE PTR LAYOUT

1'- 0"

~"
~~

EDGE OF SHOULDER

b
'

13. For 6 - lane layouts and above, see Contract.

SENSOR LEADS
EDGE OF LANE

FOR CONDUIT DIAM.


SEE NOTE 8

-- ~~ [-- -~ -r=.a..,-. - -- )2
--
T"'"-

11

HOME RUN CONDUIT


(UNDER ROADWAY)
(WHERE APPLICABLE)

SECTION

11. All loop wire, loop leads, and piezo leads shall be labeled with colored electrical tape at all Junction
Boxes, Pull Boxes and Cabinets, according to the Color Code Identification Chart. For Wire Color
Code Detail see Standard Plan J-50.30.

L2

== 1' 0"

CONDUIT FOR
LOOP WIRES

10. Junction boxes installed in the paved shoulder or median shall be a Heavy Duty Junction box.
If box is installed in unpaved shoulder, use type 1 or 2. See Standard Plan J-40.10 for size and type.
See Standard Specification 9.29.2(1)8. for further information.

6'- 0"

JUNCTION BOX
-SEE NOTE 10

LOOP LEAD-IN
WIRES

Use Schedule 80 PVC, HOPE, or steel conduit under the roadway. For conduit installation
see Standard Specification 8-20.3(5).

12. Cabinet can be placed on either side of road depending on


terrain/slope, etc. It does not have to be placed on
increasing milepost side of the roadway.
=1'- 0"

7
8

9.
PIEZO CAPACITANCE
SPECIFICATIONS

Lane 1 - (drive lane) - Loop L 1, Piezo P1, Loop L2

SHOULDER NOTCH
SEE NOTES 6 AND
FOR CONDUIT SIZE
SEE NOTE
EDGE OF LANE

Use Schedule 40 PVC conduit from the Junction box to the Cabinet. Where there are 2 to 4 lanes,
use one 1 1/4" min. conduit for each direction of travel. Where there are 5 lanes in either direction
of travel, use one 2" min. conduit in each direction. Where there are 6 or more lanes in either
directon, use one 3" min. conduit for each direction.

c::::::::i>

INCREASING MILEPOST
DIRECTION
JUNCTION BOX
-SEE NOTE 10

8.

'
~
11

>-

!::.

EDGE OF

~SHOULDER

PERMANENT TRAFFIC
RECORDER INSTALLATIONS
STANDARD PLAN .J-50.20-00

OFFSET LANE LINE

SHEET 1 OF 3 SHEETS
APPROVED FOR PUBLICATION

SHOULDER NOTCH
LOOP SAW CUT
DETAIL

DETAIL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

....1
....1

Cl
Cl

::::i

0::

LL.

;:

L2

Cl

P3

.
.
2

LANE4

:~a"

L4

EDGE OF LANE\

L3

-- -~-- -~'\

CONDUIT FOR
LOOP WIRES

' '"''"'

vv vv

:vYYYYYYYYYYYYYY

EDGE OF SH OULDER

LEAD-IN SAWCUT (TYP.)

MEDIAN
HOME RUN CONDUIT
- SEE NOTE 9 X X X X

EDGE OF SH OULDER

_j

......_ .-::-_,_~,-~

"f

L3

"~

I~

I
LANE 1

16'-

SHOULDER NOTCH
- SEE NOTES 6 AND 7
FOR CONDUIT SIZE
-SEE NOTE 8

..
.
..

on::

I:- .:.
P1

~~
.]~-------.. ~
j

L4

2'.:- o.

-2'

_L_ L..-----1

______7 ______________

P2

CXlli
-' ~

LANE2

<

.l!iL..

EDGE OF SHOULDER

SECTION

~xxxxxxxxx

X X X X X

EDGE OF LANE

HOME RUN CONDUIT


(UNDER ROADWAY)
(WHERE APPLICABLE)

cxxx

JUNCTION BOX
-SEE NOTE 10

EDGE OF LANE

EDGE OF SHOULDER

LOOP LEAD-IN

I-

P4

~~~~

7
8

JUNCTION BOX
-SEE NOTE 10

2'- 0"

SHOULDER NOTCH
SEE NOTES 6 AND
FOR CONDUIT SIZE
SEE NOTE

ADVANCED INDUCTION LOOP


MODIFIED TYPE 2 (TYP.) SEE NOTE 3

: 16'- 0"

I'
LANE3

=r

11

..-------.
L2

::

.
.

SENSOR LEADS

------ :-~-..________

OFFSET LANE LINE (TYP.)

------- _ll_------------------------INCREASING MILEPOST


DIRECTION

'7

c-.

FOR CONDUIT DIAM.


SEE NOTE 8

EDGE OF

~SHOULDER

JUNCTION BOX
-SEE NOTE 10

ll

INDUCTION LOOP I PIEZO AXLE SENSOR


NUMBER IDENTIFICATION

SHOULDER NOTCH
SEE NOTE 8

Lane 1 -(drive lane) -Loop L1, Piezo P1, Loop L2

DETAIL

Lane 2- (pass lane) - Loop L3, Piezo P2, Loop L4


Lane 3- (drive lane) -Loop L1, Piezo P1, Loop L2

PERMANENT TRAFFIC
RECORDER INSTALLATIONS
STANDARD PLAN .J-50.20-00

Lane 4 - (pass lane) - Loop L3, Piezo P2, Loop L4

SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

PLAN VIEW

TYPICAL 4 LANE PTR LAYOUT WITH MEDIAN

Pasco Bakotich Ill


06-03-11
----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

SEE NOTE 8

SHOULDER NOTCH
SEE NOTES 6 AND
FOR CONDUIT SIZE
SEE NOTE
EDGE OF LANE
LOOP LEAD-IN
WIRES
LANE1

L2

:::::2'- 0"

L4

LO OPS CENTERED IN LANE

I-

L3

LANE3

:::::::2'- 0"

L6

:n:_..

P3

-- 1.....;,::.:;::-.:.~

SECTION

L5

1
~

--

LEDGE OF SHOULDER

\.&

..

LANE3

.,...:::r;r.: ~

~ -

---- --- --

EDGEO F SHOULDER

P3

-~

L5

-' ~

li~

LANE2

--

..

.....,..,_

coo.:

...

....
....
..

-- ,......~~
----- --- --

Lane 1 -(drive lane) -Loop L1, Piezo P1, Loop L2

Lane 2- (center lane) - Loop L3, Piezo P2, Loop L4

Lane 2- (center lane) -Loop L3, Piezo P2, Loop L4

Lane 3 - (drive lane) - Loop L1, Piezo P1, Loop L2

Lane 3- (center lane) - Loop L1, Piezo P1, Loop L6

\ _ EDGEO F LANE

I;= 2- a"

I
SENSOR LEADS

I
HOME RUN CONDUIT UNDER
THE ROADWAY (TYP.)

P2

__?

L3

I:--2' -0"

L4

LOOPS CENTERED IN LAN E

FOR CONDUIT DIAM.


SEE NOTE 8

'

------ r ---f~
~:

1 114"

EDGE OF

L2

P1

~SHOULDER

-2' - 0"
I ;-

SHOULDER NOTCH
- SEE NOTES 6 AND 7
FOR CONDUIT SIZE
-SEE NOTE 8

Lane 1 - (drive lane) - Loop L1, Piezo P1, Loop L6

L6

16'- 0"

LANE1

INDUCTION LOOP I PIEZO AXLE SENSOR


NUMBER IDENTIFICATION

MEDIAN

(XXXXXXXXXX

EDGE OF LANE

'<.[

~...v/,"1.//?X

c..

1-

'
JUNCTION BOX
-SEE NOTE 10

JUNCTION BOX
-SEE NOTE 10

HOME RUN CONDUIT


(UNDER ROADWAY)
(WHERE APPLICABLE)

-SEE NOTE 9

-- ~-- --- 1;..-o --

EDGE OF SHOULDER

CONDUIT FOR
LOOP WIRES

~ HOME RUN CONDUIT

P2

7
-

-- 2' - 0" I
16'- 0"

LANE2

SHOULDER NOTCH
OFFSET LANE LINE (TYP.)

EDGE OF LANE

-e-----~-----------------------------------------::

::::: 2' - 0"

~~~i~~iu~~\,~"

\_

;UNCTION BOX
-SEE NOTE 10

_ _ : : : OF SHOULDER
INCREASING MILEPOST
DIRECTION

DETAIL

PERMANENT TRAFFIC
RECORDER INSTALLATIONS
STANDARD PLAN .J-50.20-00
SHEET 3 OF 3 SHEETS
APPROVED FOR PUBLICATION

SEE NOTE 8

Pasco Bakotich Ill

PLAN VIEW

TYPICAL 6 LANE PTR LAYOUT WITH MEDIAN

.....
fll

-----=s=rA=TE'"""o=Es=IG'""NE=N=GIN=E=ER___

06-03-11
DATE

Washington State Department of Transportation

NOTES

-<i==

EDGE OF SHOULDER
\

DECREASING MILEPOST
DIRECTION

--------~------------------------------------------------------------------------------------------

2. The Contractor shall notify the Statewide Travel and Collision Data Office (STCDO) (formerly
TOO) a minimum of five working days prior to the scheduled site installation. An inspector
from the WSDOT STCDO shall be on site for all phases of installation.

EDGE OF LANE

ADVANCED INDUCTION LOOP


MODIFIED TYPE 2 (TYP.)
-SEE NOTE 3

PIEZO AXLE SENSOR (CLASS 1)


(TYP.)

....1
....1

Cl
Cl

bv

L4

~-------11--

B
A
C<lW
...... ~------..... t--------1

L3

c:::O

oz

= w
ow

::J

c:::

1. See Standard Plan J-50.30 for Piezo Axle Sensor General Installation instructions, and Modified
Type 2 Loop Wiring Details.

LANE2

LL.

4. The loops and axle sensors shall be cut in the final lift of asphalt after lane striping is completed. All PTR loops shall be spaced @ 16ft. leading edge to leading edge.

(/)

SEE SAWCUT
LOOP DETAIL

P4

Nl
......

3. The loop inductance of two loops within the same lane shall be within 20 micro henries
of each other. All piezo ohms readings shall be 0\L from shield to center conductor.
Class WIM piezo capacitance shall be 8nf to 20nf.

P3

5.
TEMPERATURE SENSOR
- IN CONCRETE

P1

;::as
A

LANE1

L1

OFFSET LANE
LINE (TYP.)

EDGE OF LANE

EDGE OF SHOULDER

6. The shoulder notch length along the roadway shall be 4" or the conduit diameter plus 2" or
whichever is larger. The shoulder notch width perpendicular to the roadway shall be the
conduit size plus 1/4".
7. After all sensor leads are installed, seal the end of the conduit with conduit sealant. Use
asphalt cold-patch to fill notch unless otherwise specified in Contract.

Co~

For concrete pavement lanes with asphalt shoulders, install all of the piezo sensors and
splices in the concrete lane. Also, for concrete pavement lanes, install the loops 4" to 6"
away from the expansion joints.

~ ~

- - .-

ll

.1

INC:~:,:: ~~~:O:T--::-------~ ~ ~ -::SC~:::~ ~ -;~r--~ ~ ~ ~---~.- ~-~ -.~.~- ~ ~ ~ ~ ~ ~---DIRECTION

PVC CONDUIT- SEE NOTE 8

JUNCTION BOX TYPE 1 OR 2 (TYP.)


-SEE STANDARD PLAN J-40.10
I
I

..........!
INDUCTION LOOP I PIEZO AXLE SENSOR
NUMBER IDENTIFICATION

CABINETSEE NOTE 12

INDUCTION LOOP TO
PIEZO AXLE SPACING

SEE NOTE 8

8.

Use Schedule 40 PVC conduit from the Junction Box to the Cabinet. Where there are 2 to 4
lanes, use one 1 1/4" min. conduit for each direction of travel. Where there are 5 lanes in
either direction of travel, use one 2" min. conduit for each direction. Where there are 6 or
more lanes in either direction, use one 3" min. conduit for each direction.

9.

Use Schedule 80 PVC, HOPE, or steel conduit under the roadway. For conduit installation,
see Standard Specification 8-20.3(5).

IF ROADWAY IS ASPHALT,
PLACE TEMPERATURE
SENSOR HERE

Lane 1 - (drive lane) - Loop L 1, Piezo P1, Loop L2

RURAL

6'

12'

URBAN

2'

10'

10. Junction Boxes installed in the paved shoulder or median shall be a Heavy Duty Junction Box.
If box is installed in unpaved shoulder use type 1 or 2. See Standard Plan J-40.1 0 for size
and type. See Standard Specification 9-29.2(1)8. for further information.
11. All loop wire, loop leads, and piezo leads shall be labeled with colored electrical tape
at all Junction Boxes, Pull Boxes and Cabinets. For Wire Color Code Identification
Chart & Detail see Standard Plan J-50.30.

Lane 2 - (pass lane) - Loop L3, Piezo P2, Loop L4


PLAN VIEW

TYPICAL 2 - LANE WIM LAYOUT

13. For 6-lane layouts and above, see Contract.

1'- 0"

~"
. "J )X

3'~ (TYP.)

7f!==r====~~~~ ~
6'- 0"
b

'

12. Cabinet can be placed on either side of the road depending


on terrain/slope, etc. It does not have to be placed
on increasing milepost side of the roadway.

SENSOR LEADS

14. Concrete lanes shall use 11' class 1 piezos.


Asphalt lanes with 1' shoulder or less may
use 12' piezos. For shoulders over 1',
use 13' piezos.

L2

FOR CONDUIT DIAM.


SEE NOTE 8

EDGE OF

~SHOULDER

WEIGH-IN-MOTION
SITE INSTALLATION
DETAILS
STANDARD PLAN .J-50.25-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

SHOULDER NOTCH
LOOP SAW-CUT
DETAIL

DETAIL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

__.--z._._____,

DECREASING MILEPOST
DIRECTION

EDGE OF SHOULDER

"
1 1/4 MIN. SCHEDULE 40 PVC

--------

CONDUIT- SEE

NO:..-~ .......... .......

JUNCTION BOX TYPE 1 OR 2 (TYP.)


~ SEE STANDARD PLAN J-40 10

i -+0"

SENSOR LEADS

-------------------------------~--------------------1-------------------------------------

EDGE OF LANE
FOR CONDUIT DIAM .
SEE NOTE 8

..J
..J

Cl
Cl

L2

:J

L1

ADVANCED INDUCTION LOOP


MODIFIED TYPE 2 (TYP.)
-SEE NOTE 3

c:::
w
LL.

LANE3
P2

EDGE OF

P1

HOME RUN CONDUIT -SEE


NOTE 9, SHEET 1

LANE4

~SHOULDER

A
;

EDGE OF LANE

P4

SHOULDER NOTCH

P3

DETAIL

L4

L3

SHOULDER NOTCH - SEE NOTES 6 AND 7


FOR CONDUIT SIZE - SEE NOTE 8
EDGE OF SHOULDER
EDGE OF LANE
JUNCTION BOX TYPE
1 OR 2 (TYP.)- SEE
STANDARD PLAN J-40.10

LOOP LEAD-IN
WIRES

CONDUIT FOR
LOOP WIRES
EDGE OF LANE

L3

LANE2

P3

L4

~
(TYP.)

HOME RUN CONDUIT


(UNDER ROADWAY)

P4

SECTION

P1

A
EDGE OF LANE

A
OFFSET LANE
LINE (TYP.)

L1

LANE 1

JUNCTION BOX TYPE 1 OR 2 (TYP.)


SEE STANDARD PLAN J-40.10

CABINET

INCREASING MILEPOST
DIRECTION

SEE NOTE 8

INDUCTION LOOP TO
PIEZO AXLE SPACING
A

RURAL

61

121

URBAN

21

101

PLAN VIEW

TYPICAL 4- LANE WIM LAYOUT WITH MEDIAN


INDUCTION LOOP I PIEZO AXLE SENSOR
NUMBER IDENTIFICATION

INCREASING DIRECTION
Lane 1 - (drive lane) - Loop L1, Piezo P1, Piezo P2 Loop L2
1

Lane 2 - (pass lane) - Loop L3 1 Piezo P3 1 Piezo P4 1 Loop L4

WEIGH-IN-MOTION
SITE INSTALLATION
DETAILS
STANDARD PLAN .J-50.25-00
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

DECREASING DIRECTION

Lane 3 - (drive lane) - Loop L1 Piezo P1 Piezo P2 Loop L2


I

Lane 4- (drive lane) -Loop L3 1 Piezo P3 1 Piezo P4 1 Loop L4

Pasco Bakotich Ill


------~~~~~-------

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

THESE ARE GENERAL INSTALLATION INSTRUCTIONS

JUNCTION BOX~

....1
....1

0
0

::J

SEE SPECIFIC MANUFACTURER'S INSTALLATION INSTRUCTIONS


IN THE SPECIAL PROVISIONS OF THE CONTRACT
1. Using paint and a straight edge, carefully mark the layout of the sensor installation.
Ensure sensors are placed exactly perpendicular to the flow of traffic and that all
lines are straight. Verify that the piezo coax length can reach the cabinet with a
minimum of 8ft. of cable inside the cabinet.

JUNCTION BOX

1 - - - - - _ ] _ - - - - - - -1

2C(SH) CABLE

0::

-0 ..
------------- ~-------- ~~ -- L_
~

EDGE OF SHOULDER

::

SPLICE (TYP.)

I
I

11..

I
I
I
I

SHOULDER NOTCH

51

L----------

1/4" HOME RUN SENSOR SLOT


-SEE NOTE 3

3/8" HOME RUN


SLOT (TYP.)

F1
-

I
I
I
I
I
I
I
1

2. Using a wet-cutting pavement saw with a 3/4" blade width, cut the piezo slot approximately 4 to 6 inches longer than the piezo length. The piezo slot depth must be a
minimum of 1" to a maximum of 1 1/2".
3. Lead-in cuts for the piezo coax should be 1/4" minimum wide, at a depth of 1 1/2" to 2".
SEE SPECIAL PROVISIONS IN
THE CONTRACT FOR THE
ROADWAY LOOP CABLE TYPE

EDGE OF LANE
TRAFFIC FLOW

'

~[

3/4" S OT
-SEE NOTE 2

6'- 0"

9. Mix epoxy according to manufacturer's recommendations and pour in slot into small
bead. Make sure grout pours into slot slowly to avoid air pockets. Start at the piezo
end and pour toward the coax to piezo attachment point. Repeat until the slot is
completely full, at least two passes.

6'- 0"

HOME RUN C:.::IT UNDER


THE ROADWAY (TYP.)

10. Use a putty knife with a notched center to spread the epoxy smooth the length of
the sensor.

_fi

11. Remove tape.


MODIFIED TYPE 2 ADVANCE
LOOP WIRING DIAGRAM

SAWCUT LAYOUT
FOR PERMANENT TRAFFIC RECORDER SITE

TOP OF EXISTING PAVEMENT OR


LEVELING COURSE OF NEW PAVEMENT

RADIUS VARIES DEPENDING ON


SAW BLADE DIAMETER

12. Class 2 sensor installation is complete after epoxy has cured. Class 1 WIM sensors
shall be sanded flush with the pavement surface the entire length of the piezo sensor.
Use a belt sander with a coarse grit paper to get an even surface finish.
13. Lead-in placement and saw-cut methods vary depending on Regional preference and location.
Coordination between WSDOT and
Contractor is needed to determine
method to be used prior to installation.

(MODIFIED TYPE 2 LOOP SHOWN)

EDGE OF LANE

7. Install the piezo according to manufacturer's recommendations. Class 2 piezo sensors shall be placed at bottom of piezo slot. Class 1 sensors must be installed at a
specific depth particular to each site location. This depth will be measured and set
by Statewide Travel and Collision Data Office (formerly TDO) inspector on site.
8. Place two pieces of 2" duct tape along the length of the sensor slot. Tape should
be about 1/16" from slot edge.

1/4" SLOT (TYP.)

---'----'-----1

5. Completely dry piezo slot. No moisture or oily residue shall be allowed in piezo slot.
6. After piezo cut is dry, wire brush sides and bottom of entire piezo slot. Blow out
loose debris.

LEAD-INS OR HOME RUN CUTS

~--:r- SHALL NOT EXCEED SHOULDER DEPTH

// ~

4. Using a pressure washer, remove all slurry and loose material from the piezo slot.

4"T06"

TOP OF EXISTING PAVEMENT


OR LEVELING COURSE
OF NEW PAVEMENT

SAWCUT

14. Place the Installation Brackets on the sensor


every 12" for class 2 sensor, and every 8" for
class 1 sensor, for the length of the sensor.
Use the 3/4" brackets.

--j I"

1/4" WIDE
SAWCUT

0::

ow
~ tu
<( 0::

POLYPROPYLENE HIGH-TEMP
ROPE OR BACKER ROD

:r:O
D..

11..

1-

cno
<(()

oz
J: w
1- ::2:

w
wo

D..

PERMANENT TRAFFIC
RECORDER AND
WEIGH-IN-MOTION DETAILS
STANDARD PLAN .J-50.30-00

SENSOR SLOT

HOME RUN SLOT

SECTION

BEFORE SENSOR INSTALLATION

SECTION

SHEET 1 OF 3 SHEETS

APPROVED FOR PUBLICATION

= N

;:::2;

SECTION

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

....1
....1

0
0

::::i

z
a::

::s

FILL SENSOR SLOT WITH GROUT


-SEE NOTE 9

LL.

LL.

PIEZO AXLE SENSOR


CLASS 1 OR 2
-SEE NOTES

FILL SENSOR SLOT WITH GROUT


-SEE NOTE 9
PIEZO AXLE SENSOR
CLASS 1 OR 2

TOP OF
ROADWAY

HOME RUN SLOT

------~LEVEL
INSTALLATION
BRACKET (TYP.)

INSTALLATION
BRACKET (TYP.)

I.

SECTION

.I

3/4"

::s

4"T06"

3"

LL.

0
w

(!)

PLAN VIEW

SECTION

3/8" - SEE NOTE 7


8"

LOOP SEALANT

SENSOR LEAD
ATTACHMENT
END

8"

8"

PIEZO COAX WIRE

POLYPROPYLENE HIGH-TEMP
ROPE OR BACKER ROD

....
SENSOR
END

PIEZO AXLE SENSOR


CLASS 1 OR 2

INSTALLATION
BRACKETS (TYP.)
-SEE NOTE 14

::s
LL.

FILL SENSOR SLOT WITH GROUT


-SEE NOTE 9

4" TO 6"

3"

~~--~~~----~~~~~

SIDE VIEW

BRACKET AND PIEZO LAYOUT

HOME RUN SLOT

PERMANENT TRAFFIC
RECORDER AND
WEIGH-IN-MOTION DETAILS
STANDARD PLAN .J-50.30-00
SHEET 2 OF 3 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


------~=--------------

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

8 CIRCUIT LOOP
TERMINAL STRIP
WITH CLOSED
BACKPANEL

NOTES
COLOR CODE IDENTIFICATION
COLOR

WIRE NO.

BLACK

BROWN

RED

ORANGE

YELLOW

GREEN

BLUE

VIOLET

GRAY

WHITE

SECOND TERMINAL
STRIP IF NEEDED
....1
....1

0
0

::::i
0::
LL.

POWER IN I BREAKER BOX


15 AMP CIRCUIT BREAKER

II

4 PLUG OUTLET

BROWN & BLACK

10

BROWN & BROWN

11

BROWN & RED

12

BROWN & ORANGE

13

BROWN & YELLOW

14

BROWN & GREEN

15

BROWN & BLUE

16

BROWN & VIOLET

17

1. The Loop and Piezo leads in all Junction Boxes


and Cabinets are to be color-coded. Use colored
tape on each specific wire, see table. Wrap the
tape on the wires approximately 6" beyond conduit
in all Junction Boxes.
SINGLE PAIR LOOP
LEAD CABLE

2. The maximum load in the cabinet is 5 Amps.


3. The cabinet may be pedestal or pad mount. See
Standard Plan J-1 0.1 0 for details.

N
.....

4. See Special Provisions in the contract for the Cabinet


dimensions. See Standard Specification 9-29.24 for
other requirements.
5.

For Grounding Details, See Standard Plan J-60.05. See


Standard Specification 8-20.3(9) for other requirements.

YELLOW BAND= 4
WHITE BAND = INCREASING
MILE POST DIRECTION

COLOR CODE WIRE DETAIL


SEE SPECIAL PROVISIONS
IN THE CONTRACT
FOR SPLICE KIT ENCLOSURE.

WHITE IS ALSO USED FOR DESIGNATING


INCREASING MILE POSTS
~

~
TO JUNCTION BOX

SEE STANDARD SPECIFICATION


9-29.12 FOR SPLICE REQUIREMENTS

TO UTILITY
SINGLE PAIR
WIRES (TYP.)

TYPICAL
SERVICE CABINET
SEE NOTES 2 THRU 5

STANDARD JUNCTION
BOX

.....'
DETECTOR 2C(SH)
CABLE

SPLICE DETAIL

(.)

:::!!:11:
Oo::
0::~

u..cn
:::i!:o
~w

:::!!:>
-<(
~a.

GRAVEL PAD

CONDUIT (TYP.)

:::i!:u..
~0

NO.

PERMANENT TRAFFIC
RECORDER AND
WEIGH-IN-MOTION DETAILS
STANDARD PLAN J-50.30-00
SHEET 3 OF 3 SHEETS

TO CABINET

APPROVED FOR PUBLICATION

FOR CONDUIT SIZE TO SERVICE


CABINET, SEE CONTRACT
TO ROADWAY
LOOPS & SENSORS

JUNCTION BOX

Pasco Bakotich Ill

.....
fll

----=s=rA=TE"""o=Es=IG""NE=N=GIN=E=ER___

JUNCTION BOX WIRING


(SHOWN PRIOR TO SPLICING)

06-03-11
DATE

Washington State Department of Transportation

NOTES

1. If parallel circuits of different sizes are


contained in one conduit, the size of the
grounding conductor shall be determined
on the basis of the largest conductor.
Only one grounding conductor is required
for each conduit, regardless of the
number of circuits contained.

TO POWER
SOURCE

I
I

-b

Ill
Ill

...

CONTINUED
ON SHEET 2

Ou
g@)
0:::~

~z
:::;;0

:>U

<(W

~~n~

--:~~

COMBINED GALVANIZED STEEL RIGID METAL CONDUIT (RMC)


AND RIGID PVC CONDUIT (PVC) APPLICATION

c<(

0
0:::

:::!

____! ___ _

__ j_~__ j__

15

____! ___ _

2. Service ground per serving utility requirement. If the utility uses aluminum service
conductors, an approved AI-Cu pressuretype ground connector shall be used to
secure the service neutral to the copper
neutral bar in the service enclosure.
Except for the above, all grounding
conductors shall be copper.
3.

Equipment grounding conductors and


grounding electrode conductors shall be
sized in accordance with the National
Electric Code (No. 8 minimum).

--~------

10
~

PVC CONDUIT (PVC) APPLICATION

()

@)~@)
1~z
c<(
:::;;0
:>U

0
0:::

<(W

:::!
<(

ow

o:::cn

___1____ _

o:::

__ j_~__ j__

___! ___ _

...

CONTINUED
ON SHEET 2

9
15

GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION

GROUND DETAILS

@)
RMC
PVC
APPLICATION APPLICATION

@
@
@

KEY

CD

SERVICE NEUTRAL

CD
CD

GROUNDING ELECTRODE CONDUCTOR

BONDING JUMPER

GROUNDED NEUTRAL BUS (COPPER)

(J)

SERVICE ENCLOSURE

EQUIPMENT GROUNDING CONDUCTOR


JUNCTION BOX

COPPER SOLDERLESS CRIMP CONNECTOR


GALVANIZED STEEL RIGID METAL CONDUIT (RMC)
RIGID PVC CONDUIT (PVC)
OPTION A - 10' RMC WITH FIELD BEND
- APPROVED ADAPTER FITIING
- GROUNDING BUSHING
OPTION B -

SERVICE GROUND

GROUNDING BUSHING
(TYP. ALL RMC CONDUIT TERMINATIONS)

ELECTRICAL LOAD SUPPORT


(LUMINAIRE POLE AND TRAFFIC SIGNAL POLE)

10' RMC
GS FACTORY ELBOWS
APPROVED ADAPTER FITIING
GS COUPLING
GROUNDING BUSHING

@
@

GROUND ROD

CLAMP

EDGE OF FOUNDATION, POLE OR SERVICE SUPPORT


JUNCTION BOX OR 8" DRAIN TILE WITH APPROVED
COVER
CODE SIZE RMC

TO SERVICE NEUTRAL BUS

TO GROUNDING TERMINAL OR CONNECTION TO


EQUIPMENT GROUNDING SYSTEM

BONDING JUMPER ATTACHED TO BOX WALL


COUPLING NUT

BONDING JUMPER ATTACHED TO BOX LID(S)


GROUND STUD. # 8 AWG (MIN.) x 4' TINNED
BRAIDED COPPER.

END BELL BUSHING


(TYP. ALL NON-METALLIC CONDUIT TERMINATIONS)

@
@

CODE SIZED PVC

NON-METALLIC CONDUIT (PVC) SCHEDULE 80

@
@
@)

HIGH-DENSITY POLYETHYLENE CONDUIT (HOPE)


BOX LID(S) GROUND STUD
CABLE VAULT
PULL BOX
ITS CABINET
EDGE OF FOUNDATION

qJ~

TRAFFIC SIGNAL CABINET

CABINET GROUNDING BUSS (COPPER)

@
@)

RIGID PVC OUTERDUCT WITH PVC OR PE INNERDUCT


GALVANIZED STEEL RIGID METAL CONDUIT OUTERDUCT WITH
PVC OR PE INNERDUCT
LOCATE WIRE. COIL 10' INSIDE CABINET, CABLE VAULT, OR PULL BOX

DETECTABLE UNDERGROUND WARNING TAPE. COIL 2' INSIDE


CABINET, CABLE VAULT, OR PULL BOX

@
@)
@
@

TRANSFORMER CABINET

CABINET MAIN BONDING JUMPER

@
@

TYPICAL
GROUNDING DETAILS
STANDARD PLAN J-60.05-00
SHEET 1 OF 4 SHEETS

GROUNDING CONDUCTOR NON-INSULATED (FROM REINFORCING CAGE)

APPROVED FOR PUBLICATION

BOX FRAME BONDING ATTACHMENT POINT


GROUND LUG WELDED TO CABINET WALL (W/ TINNED COPPER BUSS)
ITS CAMERA, RAMP METER, TRAFFIC DATA STATION, HIGHWAY ADVISORY RADIO
UNGROUNDED CABINET NEUTRAL BUSS (COPPER)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

~ Washington Stale Department of Transportation

TOP OF PAVEMENT
OR EXISTING
GROUND

TOP OF PAVEMENT
OR EXISTING
GROUND

----1
I

SECTION

0
TOP OF PAVEMENT
OR EXISTING
GROUND

COMBINED GALVANIZED
STEEL RIGID METAL
CONDUIT (RMC) AND
RIGID PVC CONDUIT
(PVC) APPLICATION

ITS - COMBINED
GALVANIZED STEEL
RIGID METAL CONDUIT
(RMC) AND RIGID PVC
CONDUIT (PVC)
APPLICATION

ITS -COMBINED GALVANIZED STEEL


RIGID METAL CONDUIT (RMC)AND
RIGID PVC CONDUIT (PVC) APPLICATION.
FIBER OPTIC CABLE ONLY,
NO METALLIC CONDUCTORS

30 OR@

~~~~~~~13SHO~
6 OR@POSSIBLE
- SEE CONTRACT
PLANS

30 OR@

. . .------'--------,_ --_T_ --_.. ------'--------,

RIGID PVC CONDUIT


(PVC) APPLICATION

ITS - RIGID PVC CONDUIT (PVC)


APPLICATION FIBER OPTIC CABLE
ONLY -NO METALLIC CONDUCTORS

FROM DIFFERENT
SERVICE

TOP OF PAVEMENT
OR EXISTING
GROUND

3
13 SHO~
6 OR@POSSIBLE
- SEE CONTRACT
PLANS

ITS - RIGID PVC


TOP OF PAVEMENT
OR EXISTING
GROUND

FROM DIFFERENT
SERVICE

GALVANIZED STEEL RIGID


METAL CONDUIT
(RMC) APPLICATION

ITS -GALVANIZED STEEL RIGID


METAL CONDUIT (RMC) APPLICATION
FIBER OPTIC CABLE ONLY - NO
METALLIC CONDUCTORS

ITS -GALVANIZED STEEL RIGID


METAL CONDUIT (RMC) APPLICATION

TYPICAL
GROUNDING DETAILS
STANDARD PLAN -1-60.05-00
SHEET 2 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

. . . Washington State Department of Transportation

l_

SUPPLEMENTAL GROUND /.I'

SERVICE

GROUND~

SERVICE GROUND

"V"
SEE STANDARD

/PUNJ-1~

SERVICE CABINET

c~

~
I ;

Cl

0::
0

I
I
I
I

I......,
I
I
I

~~

LL.

>{)

::J

:>-:

r:c

I
Cl

I
I
I
I

~~f-------------------i~
6'-0"MIN.
~
@

<(
(/)

@
NOM.

DETAIL0

SUPPLEMENTAL GROUND /.I'

l_ ~--.--..-----.--..-----.-,..------.-.....,"V"--,

SERVICE

DETAIL0

RIGID PVC CONDUIT (PVC) APPLICATION

GROUND~

SERVICE GROUND

II

TY~

II

SEE KEY ON SHEET 1


FOR PARTS

..

I>.

SEE STANDARD
PLAN J-1 0.1 0

D
SERVICE CABINET

~
6

6'-0"MIN.

~J

@~----~@
NOM.

02)~

GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION


DETAIL0

Required to supplement equipment


grounding for luminaire standards with
direct burial aerial feeds, or where
required in the plans

DETAIL0

SEE STANDARD
PLAN J-lb

~ Required at all service and separately

SEE STANDARD
PLAN J-lb

derived systems

~ Type D service cabinet shown. Use this

TYPICAL
GROUNDING DETAILS

concept for Type E cabinet or transformer.


Type D service cabinet shall be installed
on lower surface of foundation only.
Type B service cabinet and transformer
cabinet shall be installed on raised surface
of foundation only.

0
~

STANDARD PLAN J-60.05-00


SHEET 3 OF 4 SHEETS

Type B modified service cabinet


Grounding electrode conductor and equipment
grounding conductor shall not be routed through
lug on grounding bushing.

6'-0"MIN.

~
@

1---------------------1~

6'-0"MIN.

~
@

1 - - - - - - - - - - - - - - - - - - - - - - 1 ~

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

~ Washington Stale Department of Transportation

RIGID PVC CONDUIT (PVC) APPLICATION

GALVANIZED STEEL RIGID METAL CONDUIT (RMC) APPLICATION

Q)

3/8" x 2" x 2" Frame Bonding Stud Plate with 1/4NC x 1"
Stainless Steel Bonding Stud.
Weld Bonding Stud to Frame Bonding Plate.
Weld to lid support frame.
1/4" weld- 3 sides.
Grind lid bearing surface flat after welding.
All corners rounded. Corners along exposed sheared or cut edges
shall be broken by light grinding to achieve an approximate
1/16" (inch) chamfer or rounding.
Protect conductors with fireproof cloth prior to welding.
Omit Frame Bonding Stud Plate if the Frame Bonding point already exists.

EDGE OF LID SUPPORT FRAME

,----------1
I

I
I

3"

--~1

-__I_ _ _ _ _ _ _ _ _ _ _ _ _ _ _

L ____ _

~~~

:
M

~----------1

;(;(~
';:!~~

l_

Weld all around lid bonding stud- 1/4 NC x 1" stainless steelliberally coat entire assembly w/ anti-seize compound.
FRAME BONDING
BOLT

FILLET WELD AND


EDGE WELD (TYP.)

L _____ _

2"

~
c:::

BOND TINNED BRAIDED COPPER


BONDING JUMPER- #8 MINIMUM
x 4' TO FRAME BONDING STUD
LOCATION

STAINLESS STEEL
FLAT WASHER
-FENDER

------------------------------------l
I
I

~---------J

I
I

I
I

L-----------------------------------~

I
I

...
.

... <3 .. : . "<I

L ________ _

LID SUPPORTFRAMEVARIESAMONG
MANUFACTURERS'
(FIELD VARIFY)

ATTACH TO FRAME
BONDING BOLT

..

. ,<l . . . . . <1 ..
4

. .

. <<l . ". .,<1 ..


4

PLAN
4'

..
4

....._<1 ..

STAINLESS STEEL FLAT WASHER- FENDER

FLAT WASHER

~.<I ...
:

. .. <1

@TO EQUIPMENT
GROUNDING CONDUCTOR
WITH FULL CIRCLE CONNECTOR

BONDING JUMPER#8 MINIMUM x 4' TINNED


BRAIDED COPPER (BOND
JUMPER TO EQUIPMENT
GROUNDING CONDUCTOR)

. <<l . . _. .

<l ..

STAINLESS STEEL NUT- 2 EACH

@ROUTE LID BONDING JUMPER


TO LID BONDING STUD WITH FULL
CIRCLE CONNECTOR

LID BONDING DETAIL

STAINLESS STEEL FLAT


WASHER

LID TO FRAME
BONDING JUMPER

FRAME BONDING STUD1/4" NC x 1" STAINLESS STEEL


WELD TO FRAME BONDING
STUD PLATE-LIBERALLY
COAT THIS ASSEMBLY WITH
ANTI-SEIZE COMPOUND

STAINLESS STEEL
ADJUSTING NUTS

FRAME BONDING DETAIL

COPPER SOLDERLESS
CRIMP CONNECTOR

..
..

4 .

4 .

3"

I--------

. 4 .

6 .

BONDING JUMPERFRAME TO EQUIPMENT


BONDING CONDUCTOR

TYPICAL
GROUNDING DETAILS
STANDARD PLAN J-60.05-00

EQUIPMENT GROUNDING
CONDUCTOR

SHEET 4 OF 4 SHEETS
APPROVED FOR PUBLICATION

ELEVATION

GRS

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

06-16-11
DATE

~ Washington State Department of Transportation

NOTES
1. Install Galvanized Steel Rigid Metal Conduit (RMC) between the Junction Box(es) Type 1 and the DX fitting(s) "A".
RMC conduit shall also be used from the DX fitting(s) "A" to the PVC adaptor in the barrier.
PVC Conduit may be used only in stationary-form barriers. Connect to RMC using a PVC adaptor.
RMC Conduit may be used in stationary-form barriers, but it shall be used in slip-form barriers.
2. See Standard Plan D-15.10 for additional information on F-Shape barrier, or see Standard Plan D-15.20
for Single-Slope Barrier.
3.
JUNCTION BOX TYPE 1 - SEE
STANDARD PLAN J-40.10
10' - 0"
OR SEE CONTRACT

2" CONDUIT OR AS SHOWN


IN CONTRACT
SEE NOTE 1

Pipe wrap tape shall be 2" wide, 20 ml thick, and installed with 1" minimum overlap.
RETAINING WALL EXPANSION JOINT COINCIDENT WITH FOOTING
CONSTRUCTION JOINT

CURB LINE

--j
,--------------

[_

---

--------------------------------

KEYNOTES
.J
.J

LlJ
Cl
Cl

DUMMY JOINT (TYP.)

::::i

TRAFFIC BARRIER

CONDUIT DEFLECTION FITTING


TYPE "A" (TYP.) - SEE DETAIL

0::
LlJ
LL.

Junction Box (mount box so cover is flush with the barrier face with a
0" tolerance protruding beyond the barrier face and 1/8" recessed).
Use NEMA 4X Junction Box with stationary-forms- See Standard
Plan J-40.36. Use NEMA 3R Junction Box with slip-forms - See
Standard Plan J-40.37.

PLAN
SHOWN FOR DUAL-CONDUIT INSTALLATION
(SHOWN IN F-SHAPE BARRIER)

-_:.::::::.::::::::::::::

GUARDRAIL POST
TRAFFIC BARRIER END SECTION
L/2 (TYP.)

TOP OF
ROADWAY
TOP OF
BASE COURSE

L
8' - 0" MIN. (TYP.)

THRIE BEAM GUARDRAIL


(WHEN SHOWN IN THE
CONTRACT)

<t BLOCKOUT
CONDUIT

FOR

0
#4

L (TYP.)

RMC STEEL CONDUIT TO PVC PIPE


ADAPTOR (TYP.) - SEE NOTE 1

x 3' - 6" (TYP.)

SECURE CONDUIT AND


BOX TO REBAR TO
PREVENT MOVEMENT

Type DX Deflection (DX) Fitting with Internal Bonding Jumper.

~ Wrap Conduit Pipe from Conduit Deflection Fitting to 1


beyond (inside) barrier surface.

1
-

0"

11 - 0" long, 3/4" thick expanded closed-cell foam sleeve around


conduit and conduit fitting. After placing wire ties, duct tape
seams and ends to seal and prevent concrete from bonding
with fitting and conduit.

CONDUIT DEFLECTION
FITTING TYPE "B" (TYP.) SEE DETAIL, SHEET 2

~ Where conduit in a structure is routed across a joint, wrap


the conduit pipe for 1 0" on each side of the joint.
1

.::::::::::::T.:!.:':'"...IJ!Ii ]Ri:0:!!3::

~ 10
GROUND LINE

...................

BUNDLE (2) R1 #5, (2) R2 #5 REBAR AJACENT TO


EACH END OF JUNCTION BOX (TYP.)
I

f--.. =_===_===_===_===---1== f-----:........:._----J:..____:._-,-------------"._-------------=::,.--_j"-..r-------__j'"-..,-----------1 I

1
-

0" long section of RMC conduit.

Deflection Fitting shall be in neutral state after installation.

"'"r-"lc_l----1

3" x 10" x 24" BLOCKOUT IN WALL TO ALLOW CONDUIT TO EXITFILL WITH EPOXY GROUT AFTER CONDUIT INSTALLATION

RMC CONDUIT SEE NOTE 1

ELEVATION

BARRIER IS SHOWN TERMINATING AT END


OF RETAINING WALL FOR CLARITY

SHOWN FOR DUAL-CONDUIT INSTALLATION


(SHOWN IN F-SHAPE BARRIER)
BARS ARE SHOWN FOR THE PURPOSE
OF DEPICTING LOCATION OF JUNCTION
BOX. ALL BARS ARE NOT DETAILED SEE STANDARD PLAN C-80.10 OR SEE
CONTRACT (TYP.)
JUNCTION BOX
3/8" DIAMETER
POLYETHYLENE
DRAIN TUBE

TOP OF
ROADWAY

/-:::: ===-=--=--:::1),::-=---=.........................
------:::1),::==--

:~~~::;~::;~-~-~r~
'
'
'
'
'
'
'
'
'
'
'

RETAINING WALL '\.;

CONDUIT INSTALLATION
IN TRAFFIC BARRIER
ON RETAINING WALL
STANDARD PLAN -1-60.11-00

I
I

SHEET 1 OF 2 SHEETS

I
I

APPROVED FOR PUBLICATION

SECTION

ISOMETRIC VIEW

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

180' - 0" MAX.


JUNCTION BOX (TYlP.) \

DUMMY JOINT (TYP.)


TRAFFIC BARRIER (TYP.)

II!

180'-0_"_M_AX
__
. ________~----------~

CONDUIT (TYP.)

I
....1
....1

CIRCUIT "TS"

LlJ

Cl
Cl

~ L't.Wlll~ ~--"T5 __ 1;== ====:f--L.~--~===== ======:,.,..!===:~"">:!:!IIIIi[ ~~~~


-,,~......,.,.:~...
c--- {~HR..r- ... ~~~~~~~---:~!:':::---~-;.-_-;.--~===----.. ________________ ----::::::w:::--...,"'""""'
......
.. .
--~~~~~

::::i

">or ..........
~

..,;,:.,;.-.-llll"'t::_

~---------

== ====== ======!.--- -;:s----~.--.:-.-....

j:l"llll _____ -

:::::::: ::::::::::::::~~::-

'

. . . . . r---L-T____i__ --S.::_:=-;~_-.=-=-=-=-=-=-=-=r=-= -= -=-=

--------

".:!:!IIIIi[

-=-= -= -= -= -= -= -=

".:!~

},ilart~_a::::_::::::::

--)mlr'_.._.....:_-_-:_-::_-:::: ::::

CIRCUIT "LT" __)

0:::
LlJ
LL.

EXPANSION JOINT (TYP.)

SCHEMATIC

Cl

SHOWN FOR DUAL-CONDUIT INSTALLATION


(CIRCUIT TYPES MAY VARY)

3/4" CLOSED-CELL FOAM


SLEEVE -WRAP 1 1/2 TIMES
AROUND CONDUIT AND
CONDUIT FITTING

2'- 0" RMC

END

START

SECTION

2'- 0" RMC

1'- 0"

TIES@ 2.5"
SPACING

1"

CLAMP CONDUCTOR TO CONDUIT PIPE


WITH LISTED GROUND CLAMP SUITABLE

~ADAPTOR ~~~-~:R ~~~~;;~:-~;~;O"' -NC.-: R:r=E:r:T: r:E=5=="~=-===ol.Ul


I.
""1r--T--H\-.....-ts~'"'*"1
uYP.)

CONDUIT PIPE

WIRE TIE (TYP.) (5) REQUIRED

...

.-

1'- 0"

CENTER CONDUIT FITTING


ROUTE #8 AWG STRANDED, NON-INSULATED GROUNDING CONDUCTOR
ALONG CONDUIT TO NEAREST IN-BARRIER JUNCTION BOX. BOND
CONDUCTOR TO JUNCTION BOX WITH FULL-CIRCLE CRIMP-ON
CONNECTOR. SECURE CONDUCTOR TO CONDUIT.

PREMOLDED JOINT FILLER


CONCRETE

CONCRETE

CONDUIT DEFLECTION FITTING "B" DETAIL


CONVERT RMC TO PVC IN STATIONARY-FORM BARRIER
1'- 0"

LlJ

ti:i
0:::

(.)

1"

I>

(.)'LI

TIES@ 2.5"
SPACING

WIRE TIE (TYP.) (5) REQUIRED

'LI

..Jfrn.'Ti/iTn='FF=Fr~FFFF;-p-,.""F:FF5l-

CONDUIT
PIPE

1F""""'~""""""""....,.,_,~......................._~~~ ~~- ~~ ~~~~~ ~~~~~ ~~~~J

....1

0
en

1'- 0"
PIPE WRAP TAPE

CENTER CONDUIT FITTING


PLACE@ EXIT
FROM STRUCTURE

PREMOLDED JOINT FILLER


CONCRETE

CONCRETE

CONDUIT PIPE

CONDUIT DEFLECTION FITTING "B" DETAIL

CONDUIT INSTALLATION
IN TRAFFIC BARRIER
ON RETAINING WALL
STANDARD PLAN -1-60.11-00

CONDUIT FITTING -TYPE DX- FOR DEFLECTION OF 30 AND 3/4" MOVEMENT

CONDUIT DEFLECTION FITTING "A" DETAIL


CONDUIT FITTING -TYPE DX- PLACE AT CONDUIT PIPE
EXIT FROM STRUCTURE

CONDUIT FITTING- TYPE DX FOR DEFLECTION OF 30 AND 3/4" MOVEMENT. CONDUIT PIPES
PLACED THROUGH RETAINING WALL TRAFFIC BARRIER SHALL BE FITTED WITH
DEFLECTION FITTINGS AT MAXIMUM SPACING OF 120'. THE DEFLECTION
FITTINGS SHALL BE PLACED AT THE TRAFFIC BARRIER OPEN JOINT
THAT COINCIDES WITH THE RETAINING WALL STEM EXPANSION JOINT
NEAREST TO THE TRANSVERSE CONSTRUCTION JOINT IN THE WALL FOOTING.

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

JUNCTION BOX (TYP.}


....1
....1

0
0

::J

NOTES

180' - 0" MAX.

TRAFFIC BARRIER

1. Install a Conduit Deflection (DX) Fitting "A" at the exit from the barrier. Install a Conduit Deflection (DX) Fitting "B" to connect
conduit ends at each concrete barrier expansion joint. See Standard Plan J-60.11 for Conduit Deflection Fitting details.

180' - 0" MAX.

CONDUIT

2. Install Galvanized Steel Rigid Metal Conduit (RMC) between the Junction Box(es) Type 1 and the DX fitting(s) "A." RMC
conduit shall also be used from the DX fitting(s) "A" to the PVC adaptor in the barrier.

0::

11..

PVC conduit may be used only in stationary-form barriers. Connect to RMC using a PVC adaptor.
RMC conduit may be used in stationary-form barriers, but it shall be used in slip-form barriers.

CONDUIT
(TYP.}

EXPANSION JOINT (TYP.}

3. See Standard Plan C-80.1 0 for additional details on Single-Slope Concrete Barrier.

SCHEMATIC
SHOWN FOR DUAL-CONDUIT INSTALLATION
(CIRCUIT TYPES MAY VARY}
10'- 0"

JUNCTION BOX TYPE 1 - SEE


STANDARD PLAN J-40.10
OR SEE CONTRACT

4. See Standard Plan J-60.11 for Conduit Deflection Fitting "B" detail - "Convert
RMC to PVC in stationary-form barrier."

I
1_,....,-~

-~~

--=- :.-_: =---= :...- ~

'

,/,'///~/

SEE NOTE 2

EXPANSION JOINT

I
~

.. ----------

----- ------ --c:::::::::::::::::.. -::::...


--------- -::::::::::::: :J--'"-

01

\__

(.-)

"'
:::::::::::::J-

"-,------------ -------------------------

,(/;(/
,' ,
.

5. Pipe-wrap tape shall be 2" wide, 20 mil thick, and installed with 1" minimum overlap.

(~

DUMMY JOINT (TYP.}

'

\__ 2" CONDUIT OR AS SHOWN


IN CONTRACT

TRAFFIC BARRIER

--------- - '

IT

: Lliill!l-

iliililL

I
I

__/

COLD JOINT- ALLOWED ONLY


IN RARE INSTANCES

EXPANSION JOINT

PLAN
(SHOWN FOR DUAL-CONDUIT INSTALLATION}

: ~. .: :.-...:: :.-..: ::...~:

~- -=---= ::-_-:: =---= _,

:::::::~:~::r.> TS o:~:;::- ::::::::::::-.:::::::::::


l~-::-_-::::-_-::::-_~_:

------------::::::::::::::::::::::::::::::::;/
-----------TRAFFIC BARRIER END SECTION

U2

L
1 - - - - - - - - - - - - - - - - - - - - - - - - r - - - - ( T Y - P . - }-------;~------8-'-_O-..-M-IN-.-(TY-P-.}-------1

CONDUIT DEFLECTION
FITTING "B"(TYP.} SEE NOTE 1

PIPE WRAP TAPE (TYP.} SEE NOTE 5

RMC STEEL CONDUIT TO PVC PIPE - - - - - - -

TOP OF
ROADWAY
TOP OF
BASE COURSE

SECURE CONDUIT AND


BOX TO REBAR TO
PREVENT MOVEMENT

AD~uYP.)-SEENOTE~2~============~==~~======~==~==~~==~=X==3'==6="(=TY=P~~F}============~==~==~~F=====F===1F====9 p====~~b===9

CONDUIT DEFLECTION FITTING


"A" (TYP.} - SEE NOTE 1

_ _ .::.:::::::.-.:~::::;:~:r~:~l~:~~:::::::::=="~~~='? :;c;:~~~~~=~:::::~~i{;;~==~~~~::,tmnm.r
II

II

II

II

ELEVATION

BUNDLE (2}
~ REBARS ADJACENT TO
EACH END OF JUNCTION BOX (TYP.}- SEE
STANDARD PLAN C-80.10 FOR ADDITIONAL
DETAILS

G)

(SHOWN FOR DUAL-CONDUIT INSTALLATION}


MINIMUM DISTANCE BETWEEN END OF
BARRIER AND CONDUIT TRANSITION
TO GRADE SHALL BE 5' - 0"

JUNCTION BOX

Junction Box (mount box so cover is flush with the barrier face with a 0" tolerance
protruding beyond the barrier face and 1/8" recessed). Use NEMA 4X Junction
Box with stationary-forms. See Standard Plan J-40.36. Use NEMA 3R Junction
Box with slip-forms. See Standard Plan J-40.37.

3/8" DIAMETER
POLYETHYLENE
DRAIN TUBE
TOP OF
ROADWAY

GROUND
LINE

Where conduit exits from a structure, wrap the conduit pipe for 1' - 0" on each side
from the exiting point.

CONDUIT INSTALLATION IN
SINGLE-SLOPE CONCRETE
BARRIER (DUAL-FACED)
STANDARD PLAN -1-60.12-00

10' - 0" long section of RMC conduit.

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Conduit Deflection Fitting shall be in neutral state after installation.


Where conduit in a structure is routed across a joint, wrap the conduit pipe for
1' - 0" on each side of the joint.

COLD JOINT -ALLOWED ONLY


IN RARE INSTANCES

BARS ARE SHOWN FOR THE PURPOSE OF


DEPICTING LOCATION OF JUNCTION BOX
(TYP.} ALL BARS ARE NOT DETAILED SEE STANDARD PLAN C-80.10 OR SEE
CONTRACT

KEYNOTES

~ Where conduit in a structure is routed across a cold joint with continuous reinforcing
steel, install premolded joint filler and wrap the conduit pipe for 1'- 0" on each side
of the joint. Omit pipe-wrap tape on PVC conduit.

p====*=w======9

Pasco Bakotich Ill

SECTION

.....

STATE DESIGN ENGINEER

5120113
DATE

. . . Washington State Department of Transportation

PLUMB LINE - SEE NOTE 4 ~


I

, MAX.,

NOTES

STAINLESS STEEL
CHANNEL SUPPORT

1. Drilling through reinforcing steel is not allowed. If


steel is hit while drilling, the location shall be moved
and the abandoned hole filled with grout conforming
to Standard Specification 6-02.3(20}. There shall
be a minimum of a 3" edge distance to the centerline of anchor holes in concrete. Mount the stainless steel support using an approved resin bonded
anchor system. Anchors shall be stainless steel
and shall be of 3/8" diameter (expansion anchors
are not allowed). Anchor Bolt embedment of 4 1/2"
minimum.

STAINLESS STEEL
CHANNEL SUPPORT
(TYP.)

:::!

c:::
c
0
z

SECTION
CONCRETE SLAB BRIDGE

USE NEXT LARGER


TRADE SIZE CONDUIT
THAT ALLOWS FOR
FREE MOVEMENT OF
INNER CONDUIT (TYP.)

(AUTHORIZED ONLY WITH WRITTEN BRIDGE OFFICE APPROVAL,


WHERE VERTICAL CLEARANCE IS CONSTRAINED)

2. Number of clamps shall be determined by number


of conduits to be attached to the Stainless Steel
Channel Support. See Conduit Plans for conduit
routing.
3. Add additional Attachment Bolts when required to
maintain 8" maximum spacing between adjacent
Attachment Bolts.

STAINLESS STEEL
CHANNEL SUPPORT
ISOMETRIC VIEW

4.

Stainless Steel Channel to be plumb to face of


structure. Size spacer to maintain plumb line.
When barrier is not plumb, size spacer to maintain
back of barrier line.

5.

See Standard Plan J-60.14 for Column Mounting


details.

PVC CONDUIT SUPPORT DETAIL


(FOR UTILITY COMPANY USE - ONLY ALLOWED IN RARE INSTANCES,
AUTHORIZED ONLY WITH WRITTEN BRIDGE OFFICE APPROVAL,
WHERE VERTICAL CLEARANCE IS CONSTRAINED)

3/8" DIAM. RESIN BONDED


ANCHOR WITH 4 1/2" MIN.
EMBEDMENT - SEE NOTE 1

DO NOT DRILL

~INTO GIRDER

CHANNEL SUPPORT
@ 5'- 0" MAX.
ON SOFFIT

HORIZONTAL CHANNEL MOUNT


(F-SHAPE BARRIER SHOWN
APPLY TO ALL BARRIER TYPES)

CONDUIT
DIMENSIONS

01

NOMINAL
TRADE SIZE
(IN.)

OUTSIDE
DIAMETERS

1/2

0.840

3/4

1.050

1.315

1 1/4

1.660

ISOMETRIC VIEW

CONDUIT SUPPORT DETAIL


CLAMP SHALL FULLY SPAN THE
ENTIRE WIDTH OF THE CHANNEL
HARDWARE - SEE STRAP THICKNESS CHART (SEE NOTE 2)

STRAP THICKNESS
CHART
NOMINAL
PIPE SIZE
(IN.)

STRAP
THICKNESS

1 1/2

1.900

2.375

2 1/2

2.875

3.500

3 1/2

4.000

4.500

STANDARD PLAN .J-60.13-00

5.563

SHEET 1 OF 1 SHEET

6.625

1/2- 2

>OR= 1/8"

>2-5

>OR= 1/4"

>OR= 1/4"

' f)

~'@..,

~FOR RIGID GALVANIZED STEEL, SCHEDULE 40 PVC

AND SCHEDULE 80 PVC (3 1/2" SCHEDULE 80 PVC


IS NOT AVAILABLE)

STAINLESS STEEL
CHANNEL

APPROVED FOR PUBLICATION


ISOMETRIC VIEW

/.0.. CONDUIT DIAMETERS REFLECT THE DIMENSIONS

CONNECTOR BOLT
WITH LOCK WASHER
AND FLAT WASHER
(TYP.)

Pasco Bakotich Ill

.....
fll

-----:S:=TA:-=TE:-:D:=ES::::IG::-:N-:::EN::::G:::-:IN=EE:=-R- - -

STAINLESS STEEL CHANNEL SUPPORT DETAIL


(VERTICAL MOUNT SHOWN)

06-16-10
DATE

Washington State Department of Transportation

_r ROADWAY
_L _ _ _ _ _
SLOTTED STEEL CHANNEL SUPPORT
-SEE STANDARD PLAN J-60.13

SLOTTED STEEL CHANNEL SUPPORT


-SEE STANDARD PLAN J-60.13

BRIDGE

COLUMN

5' MAX. SPACING BETWEEN


COLUMN AND ROADWAY
ATTACHMENT CHANNEL

F~~~~~~~~

(i

-- ~ -

SEE STANDARD
PLAN J-16b

SEE STANDARD
PLANJ-16b

ROADWAY\.
-

SLOTTED CHANNEL
MOUNT (TYP.)

io

NOTES

1. See Standard Plan J-60.13


for Slotted Steel Channel
details.

SEE STANDARD
PLAN J-16b

2. Stainless Steel Channel


to be plumb to face of
structure. Size spacer to
maintain plumb line.

BETWEEN~
ROADWA~ _j 1

5' MAX. SPACING BETWEEN


COLUMN AND ROADWAY
ATTACHMENT CHANNEL
SUPPORT

SUPPORT

BRIDGE
COLUMN

CONDUIT - SEE CONTRACT


PLANS FOR COUDUIT
DIAM. AND QUANTITY

5' MAX. SPACING


COLUMN AND
ATTACHMENT CHANNEL
SUPPORT

BRIDGE
COLUMN

3. Slotted Channel mounting


plate shall be installed
where conduit is routed
along column.

SLOTTED STEEL CHANNEL SUPPORT


-SEE STANDARD PLAN J-60.13

4. See Contract Plans for


specified Alternative
attachment type.

CONDUIT- SEE CONTRACT


PLANS FOR CONDUIT DIAM.
AND QUANTITY
3/4" HEAVY DUTY
STAINLESS STEEL
STRAPS (TYP.)

3/4" HEAVY DUTY


STAINLESS STEEL
STRAPS (TYP.)

DEFLECTION FITTING - SEE


STANDARD PLAN J-16b

DEFLECTION FITTING
-SEE STANDARD PLAN J-16b

GROUND
LINE

GROUND LINE

!y_- _rJJ

I 'rr'

:
-------

l::',_

----

_;>-,,

\~.:c:.:::..c:..-=.-'1

----

__ .J

ROUND COLUMN MOUNT

\:~--c:_-_-,

I
I
I

GROUND
LINE

H
:1
(;I

------,

SQUARE COLUMN MOUNT

7 3/4"

DEFLECTION FITTING - SEE


STANDARD PLAN J-16b

'<:'"..... ______ ;:,:........._ ___ _

LESS THAN OR EQUAL TO 19"

JUNCTION
BOX

CONDUIT - SEE CONTRACT


PLANS FOR CONDUIT
DIAM. AND QUANTITY

ALTERNATIVE 2

VIEW0

ALTERNATIVE 1

8"MAX.

7/16" DIAM. (TYP.)

7/16" DIAM. (TYP.)


3/4" HEAVY DUTY
STAINLESS STEEL
STRAP (TYP.)

13/16" DIAM.
(TYP.)

13/16" x 1" BANDING SLOT


FOR STAINLESS STEEL
STRAP (TYP.)

13/16" x 1" BANDING SLOT


FOR STAINLESS STEEL
STRAP (TYP.)

..

STAINLESS STEEL
CHANNEL

. ..
.

I I

c.z;-

10 GAGE
STAINLESS STEEL
-TYPE 304

7,::;;:

~~

f).

I I
~-~ .-~

~- _________ . L.j_
~- __________Lj..-l-1..(..L _________ _

SLOTTED CHANNEL MOUNTING PLATE


5/8" x 4" LONG HOT DIP
GALVANIZED LAG BOLT
WITH HOT DIP GALVANIZED
FLAT WASHER

10 GAGE STAINLESS
STEEL - TYPE 304

ISOMETRIC VIEW

ISOMETRIC VIEW

3/8" x 1" LONG STAINLESS STEEL


BOLT, 2 FLAT WASHERS
AND NUT

SQUARE COLUMN MOUNT SHOWN

WOOD POLE MOUNT DETAILS

COLUMN MOUNT DETAILS

SECTION

SPACER - SIZED
TO FIT (TYP.)

.9o.

SLOTTED CHANNEL
MOUNTING PLATE

SECTION

STAINLESS STEEL CHANNEL


MOUNTING DETAILS ON
COLUMN OR POLE
STANDARD PLAN .J-60.14-00

SHEET 1 OF 1 SHEET

______ l_l _______________ _


'
---1 15/8" (TYP.)
STAINLESS STEEL

APPROVED FOR PUBLICATION

'

SECTION

STAINLESS STEEL
CHANNEL

SLOTTED CHANNEL
MOUNTING PLATE

SECTION

CHANNEL

Pasco Bakotich Ill

SECTION
ROUND COLUMN MOUNT SHOWN

.....

fll

STATE DESIGN ENGINEER

06-16-10
DATE

Washington State Department of Transportatron

NOTES

1. See Contract for head type, mounting


height, and orientation.
2. All nipples, fittings, and center pipes
shall be 1 1/2" diameter.
3.

Install neoprene gasket inside head


when flanged elbows are supplied.

4.

Extend wire sheath a minimum of 1"


inside all signal and sign housings
and terminal compartments.

5. Apply bead of silicone to the serrated


ring and around the perimeter of all
top openings prior to installation of
fittings.

SIDE MOUNT

KEY
G)

CENTER PIPE

TYPE A - PEDESTRIAN
TYPE H - VEHICLE

(]) LOCKNIPPLE

6.

Back plates shall be constructed of


anodized aluminum and shall be
mounted with stainless steel hardware.
A 2-inch-wide strip of yellow retroreflective, type IV prismatic sheeting,
conforming to the requirements of
Standard Specification 9-28.12,
shall be applied in accordance with
the manufacturer's recommendations.
The application surface of the back
plate shall be cleaned, degreased
with isopropyl alcohol, and dried prior
to application of the sheeting. See
Standard Specification 9-29.16(2)D.

7.

Drill a 1/4" drain hole in the bottom


of each signal assembly, and one in
the bottom of each pedestrian head.
When signal assembly is mounted
horizontally, drill a 1/4" drain hole at
the lowest point of each section of
the signal assembly.

@NIPPLE

G)
@
@
(j)
@

@
@
@

SERRATED ELBOW
SERRATED OR FLANGED ELBOW

TOP MOUNT

REAMED TEE WITH SET SCREW

TYPE C - PEDESTRIAN
TYPE F - VEHICLE

REAMED ELBOW WITH SET SCREW


BRONZE TERMINAL COMPARTMENT WITH:
GASKETED COVER
FASTENERS
WIRE LEADS
MOUNTING SADDLE FOR SIDE MOUNTS
1/4" DIAM. DRAIN HOLE
12 POSITION TERMINAL STRIP
WIREWAY FOR SIDE MOUNTS

14

BRONZE COLLAR - 4 1/4" I. D. OFFSET OPENING W/SET SCREWS

16

ORNAMENT CAP
NEOPRENE GASKET

@WASHER

@
@
@)
@
@
@
@
@

SIGNAL HEAD MOUNTING


DETAILS - POLE AND POST
TOP MOUNTINGS
STANDARD PLAN J-75.10-01

CONDUIT LOCKNUT
TYPE E HINGE MOUNT- LEFT OR RIGHT, SEE CONTRACT
FASTENER WITH SPACER 1/2" LAG SCREWS ON WOOD POLE
1/2" BOLTS TAPPED TO METAL POLE

oc::Jo

SHEET 1 OF 1 SHEET

FLATHEAD SOCKET BOLT


1/2" INSERT HOLE FOR EXTERNAL WIRE ENTRANCE
(REQUIRED ON TIMBER POLE MOUNTING ONLY)

TOP MOUNT

TERMINAL BLOCK AND PHENOLIC TAG


INSULINER- 1" MIN. DIAM. HOLE
SIGNAL HEAD WITH BACKPLATE

TYPE D - PEDESTRIAN OR VEHICLE (SHOWN) -

OFFSET BRONZE COLLAR TO FRONT


OFFSET BRONZE COLLAR TO BACK

PEDESTRIAN HEAD
SIDE MOUNT
15

ELEVATION
TYPEE
MOUNTING DETAILS

(LEFT SIDE SHOWN)

TYPE E - NEON GRID OR SIMILAR SIZE


LED PEDESTRIAN HEAD

APPROVED FOR PUBLICATION

Pasco Bakotich Ill


------~=--------------

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

NOTES
17

1. Type M mounting shall have "0" ring groove and


seal top and bottom of signal attachment.
2. Type M mounting for conventional heads shall have
a 2" diameter opening at the signal attachment.
3. Type M mounting for optically programmed heads
shall have a 3 1/2" diameter opening at the signal
attachment.
4. Type N mounting with optically programmed heads
shall be installed with 14" nominal arms.
5. See Standard Plan J-75.30 for tether wire, and
backplate requirements.
6. Apply bead of silicone around the perimeter of all
top end cap openings prior to installation of the
end cap assembly.

KEY

ARM MOUNT
TYPEL

G)

END CAP

1 1/2" DIAM. LOCKNIPPLE

NEOPRENE GASKET

BRONZE SERRATED ELL FITTING WITH:


3/8" STAINLESS STEEL THROUGH BOLT AND NUTS
THREE STAINLESS STEEL SET SCREWS AT
SLIPFITTER CONNECTION
THREE ALLEN HEAD STAINLESS STEEL SET SCREWS
AT CONDUIT NIPPLE CONNECTION

(j)
@

SERRATED RING WITH PINS

CD 1 1/2" DIAM. CONDUIT LOCKNUT


CD STEEL WASHER

@
@
@
@

HEX LOCKNUT WITH:


TWO ALLEN HEAD STAINLESS STEEL SET SCREWS
PIN RECEPTACLES

ARM MOUNT
TYPE LE
(TYPE L WITH
EXTENSION FITTINGS)

SPAN WIRE
TYPE P (1 HEAD)

1 1/2" DIAM. CONDUIT NIPPLE


1 1/2" DIAM. HEX LOCKNUT
MOUNTING ASSEMBLY
BRONZE ELEVATOR PLUMBIZER WITH 3/8" STAINLESS STEEL
THROUGH BOLT, WASHERS, AND TWO NUTS

@
@

ALUMINUM ARM WITH SET SCREW

2 1/2" I.D. MIN. TUBE CLAMP

INTERNALLY THREADED CLAMP ASSEMBLY WITH:


TWO SET SCREWS
1/2" " 0.045" STAINLESS STEEL BANDS
7/16" SCREW BUCKLES, WITH SWIVELS, NUTS, AND WASHERS
BAND CLIPS WITH ALLEN HEAD STAINLESS STEEL SET SCREWS

BRONZE MESSENGER HANGER WITH:


1/2" DIAM. J-BOLTS
CABLE LOCK BAR
RIVET
COTTER KEY

BRONZE INTERNALLY THREADED WIRE ENTRANCE WITH:


BUSHING INSERT
ALLEN HEAD STAINLESS STEEL SET SCREW

@
@
@
@
@

BRONZE BALANCE ADJUSTER

SLOTTED TUBE WITH CLOSURE STRIP

SPAN WIRE
TYPE Q (2 HEADS)
TYPER (3 HEADS)
TYPE S (4 HEADS)

SIGNAL HEAD MOUNTING


DETAILS MAST ARM AND
SPAN WIRE MOUNTINGS
STANDARD PLAN .J-75.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

MULTI-HEAD MOUNTING ASSEMBLY

Pasco Bakotich Ill

SPIDER ASSEMBLY
SERRATED RING WITH NO PINS
SERRATED WASHER

ARM MOUNT
TYPEM

ARM MOUNT
TYPEN

.....

fll

STATE DESIGN ENGINEER

02-10-09
DATE

Washington State Department of Transportation

NOTES
1. Backplates shall be installed
with 6 stainless steel screws
and washers.
2. Silicone top of channel and
around nipples at openings
into pole.

KEY

CD METAL OR TIMBER POLE

@
G)
@
@
(j)
@
@
@)

2" x 3/16" STAINLESS STEEL BAND WITH 2 EACH:


3/8-16 NC x 3/4" S. S. HEX HEAD BOLT
LOCK WASHERS AND NUTS

5/16" EYE AND EYE TURNBUCKLE


3/8" MILD STEEL S-HOOK

SPAN WIRE MOUNT

MAST ARM MOUNT

1/8" S. S. WIRE ROPE CLAMP (U-BOLT TYPE)


1/8" STAINLESS STEEL TETHER WIRE
WIRE CLAMP WITH LEAD WIRE WRAP
SIGNAL HEAD
6 x 8.2 LB/FT CHANNEL

TETHER WIRE DETAIL

2EACH:
1/2-13 NC x 2 1/2" HEX HEAD BOLT
LOCK WASHERS (DRILL AND TAP
POLE TO ACCEPT)

ISOMETRIC VIEW

WIREWAY DETAIL

WIREWAY (SEE DETAIL THIS SHEET)

@METAL POLE
26"

@CABINET

@
@
@
@
@
@
@
@
@
@
@
@

END BUSHING
SEALING LOCKNUT
12-13 NC x 2 1/2" S. S. HEX HEAD BOLT

=-r>------,.:

r----

CABINET WALL DRILLED 1/8" OVERSIZE OF NIPPLE

2" DIAM. x 4" NIPPLE (UNLESS OTHERWISE NOTED)

RETRO-REFLECTIVE
YELLOW TAPE

12

@7

CHANNEL DRILLED 1/8" OVERSIZE OF NIPPLE

PLAN VIEW

POLE DRILLED SO BUSHING WILL PASS THROUGH

BACKPLATE DETAIL

6063 EXTRUDED ALUMINUM FRAME

8" OR 12" SECTIONS

F24T12/CW FLUORESCENT TUBES (4 EACH)


TRANSLUCENT PLEXIGLASS SIGN FACE

8" SECTION X = 8" 1/2"


12" SECTION X= 5 1/2" 1/2"

24

1 1/2" CAST IRON HUB WITH 5/16" PIN AND COTTER KEY
SPAN

WIRE MOUNT ASSEMBLY WITH:


1 1/2" DIAM. CONDUIT LOCKNUT
1 1/2" DIAM. CONDUIT NIPPLE
BRONZE MESSENGER HANGER WITH:
-1/2" DIAM. J-BOLTS
-CABLE LOCK BAR
-RIVET
-COTTER KEY
BRONZE INTERNALLY THREADED WIRE ENTRANCE WITH:
-BUSHING INSERT
-ALLEN HEAD STAINLESS STEEL SET SCREW

ARM MOUNT ASSEMBLY WITH:


1 1/2" DIAM. CONDUIT LOCKNUT
BRONZE SERRATED ELL FITTING WITH:
- 3/8" STAINLESS STEEL THROUGH BOLT AND NUTS
-THREE STAINLESS STEEL SET SCREWS AT
SLIPFITTER CONNECTION
-THREE ALLEN HEAD STAINLESS STEEL SET SCREWS
AT CONDUIT NIPPLE CONNECTION
1 1/2" DIAM. CONDUIT NIPPLE
SERRATED RING WITH NO PINS

SIDE POLE MOUNT ASSEMBLY WITH:


1 1/2" DIAM. CONDUIT LOCKNUT
1 1/2" DIAM. CONDUIT NIPPLE
SERRATED RING WITH NO PINS

@
@
@

1 1/2" SERRATED ELBOW

!i

ISOMETRIC VIEW

1 1/2" DIAM. NIPPLE (DRILL AND TAP POLE TO ACCEPT)


2 EACH:
1/2-20 NF x 3/4" STAINLESS STEEL HEX HEAD BOLT
LOCK WASHERS (DRILL AND TAP POLE TO ACCEPT)
MOUNTING BRACKET

SIDE POLE MOUNT


ELEVATION VIEW

::c

ISOMETRIC VIEW

INTERNALLY ILLUMINATED SIGN DETAILS

Ct!J (f) C(0


SCOOP

FULL CIRCLE

TUNNEL
PERSPECTIVE VIEWS

VISORS

C(D ~Q)
g~ro~~

ANGLE
45 SHOWN - SEE
CONTRACT PLANS FOR
ANGLE AND LENGTH "L"

MISCELLANEOUS
SIGNAL DETAILS
1/8" DRAIN HOLE

SECTION

STANDARD PLAN J-75.30-01

ELEVATION VIEW

CABINET MOUNTING DETAILS

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

6" DIAM. HAND HOLE AND


REINFORCEMENT RING (TYP.) INSTALL ON TOP OF MAST ARM AT
EACH SIGN LIGHT LOCATION,

NOTES

ISOLATION SWITCH ENCLOSURE- MOUNT


ABOVE CENTER OF ROADWAY SHOULDER
ON THE FRONT SIDE OF THE STRUCTURE

BACK OF SIGN

~~ NO~T LE_S~S~~

(SEENOTE8) nn~~~~~~~~~~~~~~~~~~~~~~~~fn

1.

Typical view shown. Verify power source location, quantities, location of signs
and sign structure fixtures in contract plans.

2.

Route IMSA 20-1 3C #14 cable(s) from isolation switch along inside, bottom of
the Monotube Mast Arm to the liquid-tight conduit connector(s) at hand hole(s).

3.

Route Separate IMSA 20-1 3C #14 cable from load side of terminal strip to each
additional light fixture (where applicable) and provide sufficient slack wire per
Standard Specification 8-20.3{8).

4.

Label all conductors with sign light and circuit number at isolation switch, hand
hole(s) and ballast enclosure(s). Labels shall be a PVC or Polyolefin wire marking sleeve per Standard Specification 8-20.3{8).

5.

Install quick-disconnect fuse kits between the power supply wires and the pole
and bracket cable, per Standard Specification 9-29.7. Fuse size shall
be 200% larger than load size.

6.

The conductors in the IMSA 20-1 3C #14 cable shall be black, red and white.
The white conductor shall be permanently identified as an equipment grounding
conductor, per the NEG.

__ __
THAN 3'- 0"

DRILL AND TAP MONOTUBE


FOR 3/4" go LIQUID-TIGHT
CONDUIT CONNECTOR
3/4" LIQUID-TIGHT
FLEXIBLE METALLIC
CONDUIT- 24" LONG, MAX.

DETAIL

TERMINATE EQUIPMENT
GROUNDING CONDUCTOR
ON TERMINAL BLOCK

3/4"

IMSA 20-1 3C #14 CABLE


-SEE NOTE 2

PULLING GRIP OR TWO SCREW


CONNECTOR - SIZE TO SECURE
POLE AND BRACKET CABLE

7. All GRS conduits embedded in foundation shall be terminated with Grounding


End Bushing and bonded to the Foundation Grounding Bus. All PVC conduits
embedded in foundations shall be terminated with End Bell Bushing.

SIGN LIGHTING LUMINAIRE


AND CONDUIT (TYP.)
6" DIAM. HAND HOLE CENTERED
OVER NEMA TERMINAL CABINET IF NO OTHER HAND HOLE IS WITHIN
1'- 6" OF CABINET (SEE NOTE 8)

8. Hand holes shall be installed at the time of fabrication. Only additional conduits
for lighting accommodations to previously non-illuminated structures may be
installed in field as long as the proper repairs are made to the structure.

TERMINAL CABINET MOUNTING


- 3/8" DIAM. x 1 1/2" BOLT, WASHER
1/4" GAP WITH 1/4"' THICK NYLON
BUSHING WASHER FOR SPACER
-4 LOCATIONS

MONOTUBE

POLE AND BRACKET CABLE - INSTALL


FROM THE QUICK DISCONNECT FUSE
KITS TO THE ISOLATION SWITCH

NEMA 3R STAINLESS STEEL TERMINAL CABINET


- FOR ISOLATION SWITCH ENCLOSURE,
SEE STANDARD SPECIFICATION 9-29.25

EQUIPMENT GROUNDING
CONDUCTOR

9. All nuts, bolts, washers, and other hardware shall be stainless steel.
10. All holes shall be drilled and tapped.
11. Use the Retrofit Details only when the following conditions apply:
A. Existing W4 x 13 Luminaire Brackets are to be reused for a new
Sign Lighting Luminaire

EQUIPMENT GROUNDING CONDUCTOR


- SIZE PER NEC. MINIMUM SIZE #8
POLE AND BRACKET
CABLE

1 1/2" DIAM. TAPPED HOLE


WITH THREADED CONDUIT
AND LOCK NUT (TYP.)

...Hnh-----' ___[

IMSA 20-1 3C #14 CABLES


-SEE NOTE 2

SECTION

POLE AND BRACKET CABLE


- INSTALL FROM QUICK DISCONNECT
FUSE KITS TO ISOLATION SWITCH

12. If the sign structure includes a maintenance walkway, the Luminaire Mounting
Plate shall be bolted to the walkway grating.
PHENOLIC TAG- INSTALL 6" ABOVE
HAND HOLE, TAG SHALL BE STAMPED
WITH POWER SUPPLY VOLTAGE, SERVICE
SOURCE NUMBERS AND LETTERS

6" x 11" HAND HOLE AND


REINFORCEMENT RING

3/16" DIAM. x 1 1/2" LONG STAINLESS


STEEL BOLT WITH WASHER AND NUT
FOR GROUND- TAP 3/16" DIAM. HOLE

B. The span between the existing Luminaire Brackets is too wide to


attach a new Sign Lighting Luminaire and Luminaire Mounting Plate.

6" x 11" HAND HOLE AND


REINFORCEMENT RING SEE HAND HOLE DETAIL
(SEE NOTE 8)

QUICK DISCONNECT FUSES


-SEE NOTE 5
GROUNDING END BUSHING
-GALVANIZED RIGID STEEL
(SEE NOTE 7)

STAINLESS STEEL, SELF TAPPING


1/4" DIAM. SCREW W/S.S. WASHER,
SPACE APPROX. 9" O.C.

SCREEN GUARD
-WELDED GALV. CLOTH, 1/16" x 7/16" SQUARE,
WRAP AROUND BASE PLATE WITH 3" MIN. OVERLAP

TOP OF FOUNDATION
I

I
I
1--,--l_j
I
I

!...~!

EQUIPMENT GROUNDING CONDUCTOR


- CLAMP TO STEEL REINFORCING BAR,
SIZE PER NEC. MIN. SIZE #8

">-~

DETAIL

TO
JUNCTION
BOX

OVERHEAD SIGN
ELECTRICAL DETAILS
(MONOTUBE STRUCTURE)
STANDARD PLAN .J-75.40-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

lr-..._

"""'--- ANCHOR BOLT (TYP.)

Pasco Bakotich Ill

MONOTUBE SIGN STRUCTURE


(SEE CONTRACT PLANS FOR ORIENTATION OF SIGN STRUCTURE)

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

1 5/8"

SIGN LIGHTING LUMINAIRE

3/4" CHASE NIPPLE


WITH LOCKNUT WASHER
3/4" MALLEABLE LB
CONDULET W/ COVER

1 5/8" MOUNTING
CHANNEL

3/8" DIAM. - 16 x 1 1/2" LONG BOLT,


3/8" DIAM. WASHER

LUMINAIRE BRACKET
- W4 X 13 STEEL

1 5/8" x 1 5/8" STAINLESS STEEL


MOUNTING CHANNEL
VERTICAL BRACE
- W4 X 13 STEEL

3/8" DIAM. LOCKNUT


AND LOCKWASHER

I.

LUMINAIRE BRACKET
(TYP.)- W4 x 13 STEEL

VARIES
NOT TO EXCEED 4' - 0"

SECTION

SECTION

0
6" DIAM.
HAND HOLE

SIGN FACE

0
USE DETAILS ABOVE THE MATCHLINE
ON SIGN LIGHT MOUNTING DETA~

SIGN LIGHTING FIXTURE WITH RETROFIT


FOR DETAILS NOT SHOWN SEE STANDARD PLAN G-90.40

STEEL CHANNEL
- C5 X 9 (TYP.)

~MATCHLINE

(1) 3/8" DIAM. WASHER AND


(1) 3/8" DIAM. LOCK WASHER

3/8" DIAM. X 1 1/2"


LONG BOLT

~
y

SIGN LIGHTING
LUMINAIRE

STEEL CHANNEL NUT


-GROOVED AND SERRATED,
(4 PER FIXTURE)

LUMINAIRE
MOUNTING
PLATE

VERTICAL BRACE
- W4 X 13 STEEL

SIGN FACE
3/4" DIAM. RIGID GALVANIZED
STEEL CONDUIT- MOUNTED
TO INSIDE OF VERTICAL BRACE

3/4" 45 LIQUID-TIGHT
CONDUIT CONNECTOR

ELECTRICAL CONDUIT
- FOR DETAILS NOT SHOWN
SEE SIGN LIGHT MOUNTING DETAIL

r---=-,.

1 5/8" x 1 5/8" STAINLESS STEEL


= = - - 1 ' - - MOUNTING CHANNEL
- 2 PER FIXTURE

RETAINING SPRING
-4 PER FIXTURE

LUMINAIRE BRACKET
- W4 X 13 STEEL

DETAIL

MONOTUBE
BEAM

DRILL AND TAP MONOTUBE


FOR 3/4" goo LIQUID-TIGHT
CONDUIT CONNECTOR

RIGID GALVANIZED
STEEL COUPLING

LUMINAIRE BRACKET
- W4 X 13 STEEL

3/4" STAINLESS STEEL


STRAP (TYP.)

2'- 0"

3/4" LIQUID-TIGHT FLEXIBLE


METALLIC CONDUIT - 24" LONG, MAX.

MAX.

RETROFIT MOUNTING DETAIL

USE DETAILS BELOW THE MATCHLINE


ON RETROFIT MOUNTING DETAIL

3/8" DIAM. x 1 1/2" LONG BOLT


3/8"WASHER

SIGN LIGHTING
LUMINAIRE
3/4" CHASE NIPPLE
WITH LOCKNUT WASHER
3/4" MALLEABLE LB
CONDULET WITH COVER

,_
,
1 8 112

~~
.

LUMINAIRE FIXTURE
HOUSING

1'- 10 3/4"

3/4" MALLEABLE LB
CONDULET WITH COVER

SIGN LIGHTING
LUMINAIRE

3/8" LOCKWASHER

3/4" STRAIGHT LIQUID-TIGHT


CONDUIT CONNECTOR

3/4" DIAM. RIGID


GALVANIZED STEEL
CONDUIT
3/4" LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT- 24" LONG, MAX.

3/8" DIAM. LOCKNUT


LUMINAIRE MOUNTING
PLATE

3/4" 45 LIQUID-TIGHT CONDUIT CONNECTOR


- INSTALL WITHIN 1'- 0" OF LIGHT FIXTURE

DETAIL
LUMINAIRE BRACKET
(TYP.) - W4 X 13 STEEL

OVERHEAD SIGN
ELECTRICAL DETAILS
(MONOTUBE STRUCTURE)
STANDARD PLAN .J-75.40-00
SHEET 2 OF 2 SHEETS

LUMINAIRE MOUNTING
PLATE

SECTION

LUMINAIRE BRACKET
- W4 X 13 STEEL

2'- 0"

3/4" STAINLESS STEEL


STRAP (TYP.)

MAX.

SIGN LIGHT MOUNTING DETAIL

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

NOTES

CONDUIT
OUTLET BODY

POST- SEE
STANDARD PLAN G-60.10

TOP TRUSS
CHORD

1. Typical view shown. Verify power source location, quantities, and location
of signs and sign structure fixtures in contract plans
2. Route separate IMSA 20-1 3C #14 cables from load side of terminal strip
to each additional Sign Lighting Luminaire (where applicable) and provide
sufficient slack wire per Standard Specification 8-20.3(8).

TERMINATE EQUIPMENT
GROUNDING CONDUCTOR(S)
ON TERMINAL BLOCK (TYP.)

3.

' 5' - 0" MAX. '


(TYP.)

I
STAINLESS STEEL ISOLATION
SWITCH ENCLOSURE - MOUNT
ON FRONT OF FIXTURE, PER
STANDARD SPEC. 9-29.25

STAINLESS STEEL STRAPS (TYP.)


-USE TO ATTACH CONDUIT TO
BOTTOM TRUSS CHORD

5. The conductors in the IMSA 20-1 3C #14 cable shall be black, red and
white. The white conductor shall be permanently identified as an equipment
grounding conductor per the NEC.

VERTICAL BRACE
- W4 X 13 STEEL

6. All GRS conduits embedded in foundation shall be terminated with grounding


end bushing and bonded to the ground terminal in the base of pole. All PVC
conduits embedded in foundations shall be terminated with end bell bushing.

BOTTOM TRUSS CHORD


1'- 0" MAX.

IMSA 20-1 3C #14 CABLE(S)


PHENOLIC TAG - INSTALL 6" ABOVE HANDHOLE,
-SEE NOTE 2
TAG SHALL BE STAMPED WITH POWER SUPPLY
VOLTAGE, SERVICE SOURCE NUMBERS AND LETTERS

HAND HOLE - SEE


STANDARD PLAN G-60.10

4. Install quick-disconnect fuse kits between the power supply wires and pole
and bracket cable per Standard Specification 9-29.7. Fuse size shall be
200% larger than load size.

SIGN LIGHTING LUMINAIRE


AND CONDUIT (TYP.)

U-BOLT CONNECTION (TYP.)


- SEE STANDARD PLAN G-90.30

EQUIPMENT GROUNDING
CONDUCTOR - SIZE PER NEC.
MINIMUM SIZE #8.
POLE AND BRACKET
CABLE - SEE NOTE 4

(TYP.)

Label all conductors with sign light and circuit number at isolation switch,
handhole, and ballast enclosure. Label shall be a PVC or Polyolefin wire
marking sleeve per Standard Specification 8-20.3(8).

3/4" STAINLESS STEEL


STRAP (TYP.)

7.

Hand holes shall be installed at the time of fabrication. Only additional


conduits for lighting accommodations to previously non-illuminated structures
may be installed in field as long as the proper repairs are made to structure.

8. All nuts, bolts, washers, and other hardware shall be stainless steel.
SCREEN
GUARD

U-BOLT CONNECTION (TYP.)


- SEE STANDARD PLAN G-90.30

.--_1IIIIIIIL_9:.

1 1/2" CONDUIT (TYP.)

10. Use the Retrofit details only when the following conditions apply:

CONDUIT OUTLET BODY


BOTTOM TRUSS
CHORD

TO
JUNCTION
BOX

A. Existing W4 x 13 Steel Beam sign brackets are to be reused


for a new Sign Lighting Luminaire.
B. The span between the existing Luminaire Brackets is too wide
to attach the new Sign Lighting Luminaire and Luminaire
Mounting Plate.

3/4" LIQUID-TIGHT
FLEXIBLE METALIC
CONDUIT - 24" LONG, MAX.

1 1/2" CONDUIT

TERMINAL CABINET MOUNTING


- 1 1/2" DIAM. TAPPED HOLE WITH
THREADED NIPPLE AND LOCKNUT

3/4" LIQUID-TIGHT FLEXIBLE


METALIC CONDUIT- 24" LONG, MAX.

3/4" STAINLESS STEEL


STRAP (TYP.)

1/4" GAP WITH 1/4" THICK NYLON


BUSHING WASHER FOR SPACER

DETAIL

0
POLE AND BRACKET CABLE
- INSTALL FROM THE QUICK DISCONNECT
FUSE KITS TO THE ISOLATION SWITCH

IMSA 20-1 3C #14 CABLE


-SEE NOTE 2
3/16" DIAM. x 1 1/2" LONG STAINLESS
STEEL BOLT WITH WASHER AND NUT FOR
GROUND- TAP 3/16" DIAM. HOLE

PULLING GRIP OR TWO SCREW


CONNECTOR - SIZE TO SECURE
POLE AND BRACKET CABLE
POST - SEE STANDARD
PLAN G-60.10

11. If the sign structure includes a maintenance walkway, the Luminaire Mounting
Plate shall be bolted to the walkway grating.

IMSA 20-1 3C #14 CABLE


-SEE NOTE 2

VERTICAL BRACE
- W4 X 13, STEEL

DETAIL

All holes shall be drilled and tapped.

6" x 11" HAND HOLE- FOR DETAILS


-SEE STANDARD PLAN G-60.10

GROUNDING END BUSHING


-GALVANIZED RIGID STEEL
QUICK DISCONNECT FUSES
-SEE NOTE 4
STAINLESS STEEL, SELF TAPPING
1/4" DIAM. SCREW WITH S.S. WASHER,
SPACE APPROX. 9" ON CENTER

EQUIPMENT GROUNDING
CONDUCTOR

NEMA 3R TERMINAL CABINET


-FOR ISOLATION SWITCH ENCLOSURE,
SEE STANDARD SPECIFICATION 9-29.25

POLE AND BRACKET CABLE


IMSA 20-1 3C #14 CABLES
-SEE NOTE 2

LOCK NUT (TYP.)

L..,- ....~

1 1/2" DIAM. RIGID GALVANIZED


STEEL CONDUIT

DETAIL

I
I
I

1...~,

DETAIL

SCREEN GUARD
-WELDED GALV. CLOTH,
1/16" X 7/16" SQUARE, WRAP
AROUND BASE PLATE WITH
3" MIN. OVERLAP

OVERHEAD SIGN
ELECTRICAL DETAILS
(TRUSS STRUCTURE)
STANDARD PLAN .J-75.45-00
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

SIGN LIGHTING LUMINAIRE


3/4" CLOSE NIPPLE
WITH LOCKNUT WASHER

U-BOLT CONNECTION
3/8" DIAM. - 16 X 1 1/2"
LONG BOLT, STEEL

1 5/8" x 1 5/8" STAINLESS STEEL


MOUNTING CHANNEL

3/4" MALLEABLE LB
CONDULET W/ COVER

LUMINAIRE BRACKET
- W4 X 13 STEEL

1 5/8" x 1 5/8" STAINLESS


STEEL MOUNTING
CHANNEL

VERTICAL BRACE
- W4 X 13 STEEL

BOTTOM TRUSS CHORD


3/4" STAINLESS
STEEL STRAP
1 1/2" DIAM. RIGID
GALVANIZED STEEL
CONDUIT (TYP.)

3/8" DIAM. LOCKNUT


AND LOCKWASHER
LUMINAIRE BRACKET
(TYP.)- W4 x 13 STEEL

VARIES
NOT TO EXCEED 4' - 0"

SECTION

.I

SECTION

CONDUIT OUTLET BODY


3/4" LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT
- 24" LONG MAX.

DETAIL

SIGN LIGHTING FIXTURE WITH RETROFIT


FOR DETAILS NOT SHOWN SEE STANDARD PLAN G-90.40

USE DETAILS ABOVE THE MATCHLINE


ON SIGN LIGHT MOUNTING DETA~

SIGN FACE

MATCH LINE

3/8" DIAM. X 1 1/2"


LONG BOLT

SIGN FACE
STEEL CHANNEL NUT WITH SPRING
-GROOVED AND SERRATED,
(4 PER FIXTURE)

(1) 3/8" DIAM. WASHER AND


(1) 3/8" LOCK WASHER

SIGN LIGHTING
LUMINAIRE

3/4" DIAM. RIGID GALVANIZED


STEEL CONDUIT- MOUNTED
TO INSIDE OF VERTICAL BRACE

LUMINAIRE MOUNTING
PLATE
1 5/8" X 1 5/8"
MOUNTING CHANNEL
(2 PER FIXTURE)

VERTICAL BRACE
- W4 X 13 STEEL

VERTICAL BRACE
- W4 X 13 STEEL

ELECTRICAL CONDUIT
- FOR DETAILS NOT SHOWN
SEE SIGN LIGHT MOUNTING DETAIL

CONDUIT OUTLET BODY

3/4" LIQUID-TIGHT FLEXIBLE METALIC CONDUIT


- 24" LONG, MAX.
RETAINING SPRING
(4 PER FIXTURE)

LUMINAIRE BRACKET
- W4 X 13 STEEL

LUMINAIRE BRACKET
- W4 X 13 STEEL

3/4" STAINLESS STEEL


STRAP (TYP.)

2'- 0"
MAX.

DETAIL

RETROFIT MOUNTING DETAIL


USE DETAILS BELOW THE MATCH LINE ON
RETROFIT MOUNTING DETAIL
3/8" DIAM. x 1 1/2" BOLT
MATCH LINE
3/8"WASHER

LUMINAIRE
FIXTURE
HOUSING
SIGN LIGHTING
LUMINAIRE
3/4" CLOSE NIPPLE
WITH LOCKNUT WASHER

3/4" MALLEABLE LB
CONDULET WITH COVER

,_
,
1 8 112

~~

1'- 10 3/4"

3/8" DIAM. LOCKNUT


AND LOCKWASHER

SIGN LIGHTING
LUMINAIRE

LUMINAIRE MOUNTING
PLATE

DETAIL

3/4" MALLEABLE LB
CONDUIT WITH COVER
3/4" STRAIGHT LIQUID-TIGHT
CONDUIT CONNECTOR
3/4" LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT- 24" LONG, MAX.

3/4" 45 LIQUID-TIGHT CONDUIT CONNECTORINSTALL WITHIN 1'- 0" OF LIGHT FIXTURE

OVERHEAD SIGN
ELECTRICAL DETAILS
(TRUSS STRUCTURE)
STANDARD PLAN .J-75.45-00

LUMINAIRE BRACKET
(TYP.) - W4 x 13 STEEL

SHEET 2 OF 2 SHEETS
LUMINAIRE BRACKET
- W4 X 13 STEEL

LUMINAIRE MOUNTING
PLATE

SECTION

2'- 0"

3/4" STAINLESS STEEL


STRAP (TYP.)

APPROVED FOR PUBLICATION

1'- 0"
MAX.

MAX.

SIGN LIGHT MOUNTING DETAIL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

3'- 8"
DRILL & TAP FOR 1/2-13
S. S. PENTA BOLTS
PLACE 120 APART
COAT LIBERALLY WITH
ANTI-SEIZE COMPOUND

NOTES

5/8" DIAM. THREADED INSERT


(TYPICAL) - SEE NOTE 9

3'- 2"
DIAMOND PATTERN
-SEE NOTE3

25" DIAM. CAST IRON RING


AND DUCTILE IRON
LOCKING COVER

STANDARD DUTY LID


- HINGED, SPRING
ASSISTED

BONDING JUMPER
-SEE NOTE 6

1 1/2" DIAMETER
S. S. BRIDLE RING
-SEE DETAIL

1/4-20 UNC X 1 11/16" MIN.


LENGTH THREADED BRASS
GROUND INSERT WITH STEEL
LEAD GROUND ROD BONDED
TO FRAME AND REINFORCING
SYSTEM
IDENTIFICATION
-SEE NOTE 7
CORED HOLES IN
FRAME FOR TYING
TO THE RE-BAR
(TYPICAL 4 PLACES)

(LID NOT SHOWN)

CONDUITS SHOWN EXTENDED


FOR CLARITY (TYP.)- SEE
STANDARD SPECIFICATION 8-20.3(5)

7. The system identification letters shall be 1/8" line thickness formed by engraving, casting, stamping, or with a
S. S. weld bead. See COVER MARKING DETAIL. See Standard Specification 9-29.2(4). Ductile iron lid
lettering shall be recessed.

Equipment Grounding Conductor


Copper Solderless Crimp Connector

8. Cement concrete shall be Class 4000.

Equipment Bonding Jumper- See Note 5

~-SEE

See Contract for conduit size and number

9.

NOTE 6

Provide a 1 1/2" wide x 3 1/2" high x 3/16" thick min.


flat area for lifting purposes (for Ductile Iron Lid only)

~ GRS Shown - See Contract for conduit type

<J)

11. Excavate material, place 6" crushed surfacing pad per Standard Specification Section 8-20.3(6). Field bend
#3 reinforcing bar to allow conduit into the Pull Box. Field bend reinforcing bar back into place, wire tie in (2)
places, and cast in commercial concrete (commercial concrete only allowed for box bottom/wall completion).

ISOMETRIC CUTAWAY

PVC Shown - See Contract for conduit type

3'- 0"

GROUND STUD
-SEE NOTE 5

3'- 8"

~~----------------------~~

~
0

I
!

5" MIN.

g:

HARDWARE
MOUNTING RACK
- S. S. 1 5/8" SLOTTED
CHANNEL

i
!

b
:I!

TOP OF PAVED
SURFACE

2'- 0"

82!~

~-fj:::

..... 2!

~~~-~~

TOP OF SOIL
SURFACE

"'i!()~[t
~~~~::)

!i1oirh

~~gs~~
.U..t!:!ID

(!)

~l!!iil;:!o
ooq;~:SCI)~

~n~~
~OQ~>-

"'""

R:

~~~~8

i!offi

SYSTEM
IDENTIFICATION
-SEE NOTE 7

<

~~~~~

2,:;2::1-j:::

~"(IJJ"(~

"'

GALVANIZED PULLING
IRON -1@ EACH
CORNER (4 REQUIRED)

LIFTIN~ ""' ~

OlAMON
D _/.ECESSED
PATTERN
RING AND LOCK
-SEE NOTE3

TOP

i1@~~~

'

,. .. !;::;,"

l!:

12. This drawing depicts a typical Pull Box assembly. Reinforcing not shown. Each manufacturer's Pull Box
assembly will vary. Refer to the approved manufacturer's shop drawings for all dimensions and the actual.---,-----,
arrangement.
~ ,_ i'i .k

LIFT HOLE
- 1" TO 2" DIAMETER

""'

Plastic plugs shall be put into the lid inserts after fabrication and the lid installation.

10. Capacity- conduit diameter= 40" (in.).

~ Location Wire

GROUNDSTUD
-SEE NOTE4

Minimum lid thickness shown. The diamond pattern shall be a minimum of 3/32" thick.

6. Connect a Bonding Jumper to the steel conduit bushing for GRS conduit and connect the steel conduit bushing
jumper to the equipment ground at the threaded brass ground insert. Connect the equipment grounding conductors in the PVC and/or GRS conduits to the brass ground insert. The Bonding Jumper shall be #8 min. x 4' (ft.)
of tinned braided copper between the lid and the frame of the Heavy Duty tops and from the Heavy Duty top to
the threaded brass ground insert. The Bonding Jumper shall be #8 min. x 4' (ft.) of tinned braided copper
between the lid on a Standard Duty Pull Box and the threaded brass ground insert. See Contract Plan Sheets
and Standard Plan J-60.05 for Bonding Jumper requirements.

SEE NOTE

3.

5. A 1/4-20 UNC x 3/4" S. S. ground stud with (2) S. S. nuts and (2) S. S. flat washers shall be attached to the
Standard Duty Lid and coated with anti-seize compound. Provide a 5/8" diameter cored hole in the ductile iron
lid gusset (Heavy Duty Lid) with 1/2-13 UNC x 1 1/4" S. S. bolt, (3) S. S. flat washers, and (2) S. S. nuts for the
Bonding Jumper.

SEE NOTE

SECTION

2. Use Standard Duty Pull Box and Lid when placed in unpaved areas. Use Standard Duty Pull Box in sidewalks,
walkways, and shared-use paths.
4. Standard Duty Pull Boxes installed in sidewalks, walkways, and shared-use paths shall have a slip-resistant
coating on lid and shall be installed with the surface flush with and matched to the grade of the sidewalk, walkway,
and shared-use paths. The non-slip lid shall be identified with permanent marking on the underside indicating the
type of surface treatment (see Contract Documents for details) and the year of manufacture. The permanent
marking shall be 1/8" inch line thickness formed with a stainless steel weld bead and shall be placed prior to
hot-dip galvanizing.

DRILL & TAP FOR


1/2-13 S. S. BOLT
USE HOLE FOR
BONDING JUMPER

HEAVY DUTY LID

1. The Heavy Duty Lid shall be used when a Pull Box is placed in the paved shoulder or the traveled way. Use
a 9" thick lid for new Pull Box installations. Use a 6" thick Heavy Duty Lid when converting a Standard Duty
Pull Box into a Heavy Duty Pull Box in the paved shoulder or the traveled way and no overlay is called for in
the Contract. Otherwise, see Contract Plans for overlay depth and fabricate lid thickness to match overlay depth.

~~~H

KNOCKOUT
(TYPICAL)

PULL BOX

fo
GROUND ROD
KNOCKOUT
1'- 10"

SECTION

STANDARD PLAN J-90.10-01


SHEET 1 OF 2 SHEETS

PULL BOX ASSEMBLY


(SHOWN WITH STANDARD DUTY LID)

APPROVED FOR PUBLICATION

6" DIAM. SUMP WITH


2" DIAM. DRAIN HOLE

Pasco Bakotich Ill

VIEW0

.....

STATE DESIGN ENGINEER

06-27-11
DATE

~ Washington Stale Department of Transportation

8 LOCATION WIRE - PROVIDE 1'- 0" DIAM.


LOOP ABOVE CHANNEL SECTION.
SECURE IN BRIDLE RING

SEE NOTE
CORED HOLE - DO NOT
DRILL OR TAP - DO NOT
DRILL INTO OR THROUGH
GUSSETS

6" PIPE HANGER


- SEE DETAIL

,.

11..

>u

..
.
:

I
1/4-20 UNC x 1 11/16" MIN. LENGTH
THREADED BRASS GROUND INSERT WITH
STEEL LEAD GROUND ROD BONDED
TO FRAME AND REINFORCING

<(
(/)

..

::J
:;>.:

Ill

.
...
..
.
.,

,.

HEAVY DUTY LID


- SEE NOTE 1

CABLE BUFFER
- SEE PIPE HANGER DETAIL

:
0
0:::
0

GROUND STUD -THREAD INTO PREDRILLED


HOLE IN FRAME FLANGE, DRILL AND TAP
1/2"- 13 - SEE NOTE 5

DUCTILE IRON LID

BRIDLE RING
- SEE DETAIL

NOTE 6

~~
Cl

ROUGHENED SURFACE REQUIRED


PRIOR TO CASTING BOTTOM I WALL
CONCRETE

:
.

SPLICED #3 REINFORCING
BAR (TYP.)
- SEE NOTE 11

STEEL REINFORCING
SYMMETRICAL ABOUT
CENTERLINE

'

Li

-,.,:

~"

:""-

111

II
:: : 1/

: ::

r::11

#3 REINFORCING
BAR (TYP.)
- SEE NOTE 11

1
1

I L...----.J4l%1
:_':
I-'--JL_.f---1
1

NJi

'

I :0

-~~IY

>I"

/JU_

==l===t===~= =,

#3 REINFORCING BAR (TYP.)

~ AT NO TIME SHALL THE CABLE'S

'-----

MINIMUM BENDING RADIUS


LIMITATIONS BE COMPROMISED
6" BOTH ENDS
(TYP. OF 4 PLACES)

INTERNAL OBLIQUE VIEW

i_J

Ill

FACTORY
CAST BLOCK
OUT
W/ ROUGHENED
EDGES

TIE WRAP

~~
ll

1.2 MAX

ISOMETRIC CUTAWAY

SPLIT PULL BOX ASSEMBLY

2" CLEAR (TYP.)


TO END OF
REINFORCING
BAR

FIELD
VERIFY

6"
MIN.
(TYP.)

COIL THE CABLE BY USING A "FIGURE 8"


FOLDED IN THE MIDDLE TO FORM A LOOP

VIEW0

(SHOWN WITH HEAVY DUTY LID)


SEE PULL BOX, SHEET 1, FOR DIMENSIONS NOT SHOWN

COVER MARKING
DETAIL
S.S.HEX HEAD BOLT
- 1/2-13 UNC x 15/16"
S. S. CHANNEL NUT
WITH SPRING
(PARTIAL CHANNEL
SHOWN FOR CLARITY)

HARDWARE MOUNTING RACK


- S. S. 1 5/8" SLOTTED CHANNEL

:::: 1" (TYP.) I

I-I

ITS

::::

_1

1" (TYP.)

112, <TYP.>.II_ PIPE HANGER


- S. S., 12 GAGE, 1" WIDE

S. S. HEX BOLT
3/8-16 UNC x 9"

9" DIAMETER

SEE NOTE 7

1 1/2" DIAM. BRIDLE RING


- S. S. 1/4" DIAM. WIRE SIZE
(FABRICATE IF NOT AVAILABLE
COMMERCIALLY)

PULL BOX
STANDARD PLAN J-90.10-01

CABLE BUFFER
- FLEXIBLE, PLASTIC PIPE,
6" DIAM., 1'- 0" LONG, SPLIT

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

S. S. NUT

Pasco Bakotich Ill

.....

______

------~~=A=TE-0-ES~IG~N-EN~G-IN-EE_R

PIPE HANGER DETAIL


FABRICATE IF NOT AVAILABLE COMMERCIALLY

BRIDLE RING DETAIL

LOGO DETAIL

06-27-11
DATE

. . . Washington State Department of Transportation

6'- 10"
6"

38 1/2" DIAM. CAST IRON RING


AND DUCTILE IRON LOCKING
COVER

5/8" DIAM. THREADED INSERT


(TYP.)- SEE NOTE 9

1~
~
~

-0

CORED HOLES IN FRAME


FOR TYING TO THE RE-BAR
(TYP. 4 PLACES)

STANDARD DUTY LID


- HINGED, SPRING ASSISTED
1 1/2" DIAMETER
S. S. BRIDLE RING
-SEE DETAIL

DRILL & TAP FOR 1/2-13


S. S. PENTA BOLTS (TYP. OF 4)
COAT LIBERALLY WITH
ANTI-SEIZE COMPOUND
DIAMOND
PATTERN
-SEE NOTE 3

NOTES
1. The Heavy Duty Lid shall be used when a Cable Vault is placed in the paved shoulder or the traveled way. Use a 9" thick
lid for new Cable Vault installations. Use a 6" thick Heavy Duty Lid when converting a Standard Duty Cable Vault into a
Heavy Duty Cable Vault in the paved shoulder or the traveled way and no overlay is called for in the Contract. Otherwise,
see Contract Plans for overlay depth and fabricate lid thickness to match overlay depth.
2. Use Standard Duty Cable Vault and Lid when placed in unpaved areas. Use Standard Duty Pull Box in sidewalks,
walkways, and shared-use paths.

BONDING JUMPER
-SEE NOTE6

3. Minimum lid thickness shown. The diamond pattern shall be a minimum of 3/32" thick.
4. Standard Duty Cable Vaults installed in sidewalks, walkways, and shared-use paths shall have a slip-resistant

1/4-20 UNC x 1 11/16" MIN. LENGTH


THREADED BRASS GROUND INSERT
WITH STEEL LEAD GROUND ROD
BONDED TO FRAME AND REINFORCING

coating on the lid and shall be installed with the surface flush with and matched to the grade of the sidewalk,
walkway, and shared-use paths. The non-slip lid shall be identified with permanent marking on the underside
indicating the type of surface treatment (see Contract Documents for details) and the year of manufacture.
The permanent marking shall be 1/8" inch line thickness formed with a stainless steel weld bead and shall
be placed prior to hot-dip galvanizing.
5. A 1/4 - 20 UNC x 3/4" S. S. ground stud with (2) S. S. nuts and (2) S. S. flat washers shall be attached
to the Standard Duty Lid and coated with anti-seize compound. Provide a 5/8" diameter cored hole in
the ductile iron lid gusset (Heavy Duty Lid) with 1/2- 13 UNC x 1 1/4" S. S. bolt, (3) S. S. flat washers,
and (2) S. S. nuts for the Bonding Jumper.

SYSTEM
IDENTIFICATION
-SEE NOTE 7

6. Connect a Bonding Jumper to the steel conduit bushing for GRS conduit and connect the steel
conduit Bushing Jumper to the equipment ground at the threaded brass ground insert. Connect
the equipment grounding conductors in the PVC and/or GRS conduits to the brass ground
insert. The Bonding Jumper shall be #8 min. x 4' (ft.) of tinned braided copper between the
lid and the frame of the Heavy Duty tops and from the Heavy Duty top to the threaded
brass ground insert. The Bonding Jumper shall be #8 min. x 4' (ft.) of tinned braided
copper between the lid on a Standard Duty vault and the threaded brass ground insert.
See Contract Plan Sheets and Standard Plan J-60.05 for Bonding Jumper requirements.

DRILL & TAP FOR 1/2-13


S. S. BOLT - USE HOLE
FOR BONDING JUMPER

HEAVY DUTY LID


SEE NOTE 1

\..j .~- ~- - .~}_

t-

'1-"-----------l''f'
L .... c..+:f
~- -- - ~ . -.~. -.._-----'-'---

.(1_::;.
__

~ ~:i

SECTION

SEE NOTE 1

7. The system identification letters shall be 1/8" line thickness formed by engraving, casting,
stamping, or with aS. S. weld bead. See COVER MARKING DETAIL, Standard
Specification 9-29.2{4). Ductile iron lid lettering shall be recessed.

Equipment Grounding Conductor

(LID NOT SHOWN)

8. Cement concrete shall be Class 4000.

Copper Solderless Crimp Connector

9. Plastic plugs shall be put into the lid inserts after fabrication and the lid installation.

Equipment Bonding Jumper- See Note 6

10. Capacity- conduit diameter= 60" (in.).

See Contract for Conduct Size and Number

Provide a 5" Wide x 3" High x 3/16" Thick Min.


Flat Area for Lifting Purposes (for Ductile Iron Lid Only)

11. Excavate material, place 6" crushed surfacing pad per Standard Specification 8-20.3{6).
Field bend #3 reinforcing bar to allow conduit into the Cable Vault. Field bend reinforcing
bar back into place, wire tie in (2) places and cast in commercial concrete (commercial
concrete only allowed for bottom/wall completion).

CONDUITS SHOWN EXTENDED


FOR CLARITY - SEE STANDARD
SPECIFICATION 8-20.3(5)

GRS Shown - See Contract for Conduit Type


PVC Shown - See Contract for Conduit Type
Location Wire

6'- 10"

5'- 0"

GROUND STUD (TYP.)


- SEE NOTE 5

GROUND STUD
- SEE NOTE 5 ~

12.

ISOMETRIC CUTAWAY

HARDWARE MOUNTING
RACK(TYP.)
- S. S. 1 5/8" SLOTTED
CHANNEL

IF=========n
II

/-,

:: 1,

II
II
_
II / '
IIII I, __ ,. . . )

/-,

II

1,

::

II
II
/ '
II
I, __ ,. . . ) IIII

U:~~~~~~~~dJ

+
DIAMOND PATTERN
- SEE NOTE 3
SYSTEM
IDENTIFICATION
- SEE NOTE 7

'i

1/

\
\

TOP

+
RECESSED LIFTING
\__ RING AND LOCK
(TYP.)

TOP OF PAVED
SURFACE

LIFT HOLE (TYP.)


- 1" TO 2" DIAMETER

~~~~~~~~~~~

II ,.....-'\
J
II (
II , _ /
::

/-

:: (
II , _ /

8" DIAM. KNOCKOUT (TYP.)


8EACHWALL

,.....-'\ II
(
J ::
, _ / II
/-

~ ~

T-fotl

~~~~~~==~~~

f
b
I

II

b-~~~~~~~~.!i

CABLE VAULT

GALVANIZED PULLING IRON


1 @ EACH CORNER
(4 REQUIRED)

STANDARD PLAN J-90.20-01

... .. -._:._:. :.._:.:.: ....

6" DIAM. SUMP WITH


2" DIAM. DRAIN HOLE

_j.

(
J II
, _ / II

3'- 0"

--'------

TOP OF SOIL
SURFACE

SHEET 1 OF 2 SHEETS
~

SECTION~

APPROVED FOR PUBLICATION

GROUND ROD
KNOCKOUT

CABLE VAULT
(SHOWN WITH STANDARD DUTY LID)

Pasco Bakotich Ill

VIEW0

.....

STATE DESIGN ENGINEER

06-27-11
DATE

. . . Washington State Department of Transportation

~LOCATION WIRE

BRIDLE RING
-SEE DETAIL

8" PIPE HANGER


-SEE DETAIL

..
0
0:::
0

'

<(

>(.)
::::i
:;>..:

-SEE NOTE6

GROUND STUD- THREAD INTO


PREDRILLED HOLE IN FLANGE,
DRILL AND TAP 1/2"- 13
-SEE NOTE 5

BRIDLE RING
-SEE DETAIL

SEE NOTE 5

CORED HOLE - DO NOT


DRILL OR TAP - DO NOT
DRILL INTO OR THROUGH
GUSSETS

CABLE BUFFER (TYP.)


-SEE PIPE HANGER DETAIL

..

'

ID

~BONDING JUMPER

'

u.

en

DUCTILE IRON LID

-PROVIDE 1'- 0" DIAM. LOOP ABOVE


CHANNEL SECTION SECURE IN BRIDLE RING

SPLICE CASE MOUNTING


AT SPLICE LOCATION
:

t~~Jt~:::::::::::::::::::::::f::::::::::::::::::::~:::fL~J

1/4-20 UNC x 1 11/16" MIN. LENGTH


THREADED BRASS GROUND TAP
INSERT WITH STEEL LEAD GROUND
ROD BONDED TO FRAME AND
REINFORCING

I
---------~--------

LIFT HOLE
-1" TO 2"
DIAMETER

HEAVY DUTY LID


-SEE NOTE 1

#3 REINFORCING
BAR(TYP.)
- SEE NOTE 11

TIE WRAP (TYP.)


FACTORY CAST BLOCKOUT
W/ROUGHENED EDGES

o>_.!!:
wo:::
-w

~ AT NO TIME SHALL THE CABLE'S


MINIMUM BENDING RADIUS
LIMITATIONS BE COMPROMISED

u.>

INTERNAL OBLIQUE VIEW

ROUGHENED SURFACE REQUIRED


PRIOR TO CASTING BOTTOM I WALL
CONCRETE

r- : :

:::: 1" (TYP.)

6"

CONDUIT WITHOUT INNERDUCT


SHOWN - SEE SHEET 1 FOR
CONDUIT WITH INNERDUCT

COVER MARKING
DETAIL
1" (TYP.)

ITS_[
1t2" (TYP.>.I

MIN.
TYP.

2" CLEAR (TYP.)


TO END OF
REINFORCING BAR
STEEL REINFORCING

<

VIEW0

~ SYMMETRICALABOUT

~t

CENTERLINE
Go...

SEE NOTE 7

7.08" (TYP.)

~...:;y-<...

c.~~
~~

6" (TYP.)
S. S. HEX HEAD BOLT
- 1/2-13 UNC X 15/16"
S. S. CHANNEL NUT WITH SPRING
(PARTIAL CHANNEL SHOWN
FOR CLARITY)

HARDWARE MOUNTING RACK


- S. S. 1 5/8" SLOTTED CHANNEL

ISOMETRIC CUTAWAY
_ PIPE HANGER
- S. S., 12 GAGE, 1" WIDE

9" DIAMETER
11/2" DIAM. BRIDLE RING
- S. S. 1/4" DIAM. WIRE SIZE
(FABRICATE IF NOT AVAILABLE
COMMERCIALLY)

S. S. HEX BOLT 3/8- 16 UNC x 9"

CABLE VAULT
CABLE BUFFER
- FLEXIBLE PLASTIC PIPE,
8" DIAM., 1'- 0" LONG, SPLIT

STANDARD PLAN J-90.20-01


BRIDLE RING DETAIL

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

S. S. NUT

PIPE HANGER DETAIL


FABRICATE IF NOT AVAILABLE COMMERCIALLY

SPLIT CABLE VAULT


(SHOWN WITH HEAVY DUTY LID)
SEE CABLE VAULT, SHEET 1, FOR DIMENSIONS NOT SHOWN

LOGO DETAIL

Pasco Bakotich Ill

.....

06-27-11
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

. . . Washington State

200' -+

jjj

!;;
z

::::>
0:::

- TANGENT (TYP)

100' -CURVE (TYP.)

cHANNEUZING DEVICE
(TYP.) - SEE NOTE 3

4'

36'

4'

YELLOW TA PE STRIPE

2'

36'

2'

Ill

<
z

w
w

...J

121

121

YELLOW TRPM (TYP.)

~-sE E NOTE 5

121

121

v-

121

121

121

NOTES

1. For long term projects conflicting pavement markings that are no


longer applicable shall be removed or obliterated. Temporary
markings shall be used as necessary.
2. For Hot Mixed Asphalt Pavement, a temporary striping tape shall
be installed in conjunction with DO NOT PASS and "PASS WITH
CARE" sign locations.

HOT MIXED ASPHALT PAVEMENT

BITUMINOUS SURFACE TREATMENT

3. Temporary roadside delineation with Channelization Devices is


optional. The appropriate taper length shall be U2. See Standard
Plan K-24.20 for minimum taper length (L).

TWO-LANE ROADWAY

4.

36'

121

4'

1/

121

121

liil

36'

121

liil

Ell

liil

4'

WHITE TAPE
(OR PAINT) STRIPE

liil

liil

HOT MIXED ASPHALT PAVEMENT

2'

WHITE TRPM
-SEE NOTES

For long term projects a channelization/pavement marking plan


should be implemented.

5. Temporary Raised Pavement Marker (TRPM) may be used on a


pattern spacing 5' O.C. to simulate a solid line.

2'

liil

liil

BITUMINOUS SURFACE TREATMENT

ONE-WAY TWO-LANE ROADWAY

4'

liil

36'

Ell

Ell

4'

YELLOW TAPE STRIPE

IQI

IQI

2'

YELL 0 w TRPM (TYP.)


-SEE NOTE 5

2'

ill

~
D

liil

v:

IQI

36'

IQI

IQI

IQI

TEMPORARY
CHANNELIZATION
STANDARD PLAN K-70.20-00
SHEET 1 OF 1 SHEET

TEMPORARY TURN\
ARROW (TYP.)

HOT MIXED ASPHALT PAVEMENT

APPROVED FOR PUBLICATION

BITUMINOUS SURFACE TREATMENT

....

Ken L. Smith
STATE DESIGN ENGINEER

02-15-07
DATE

fJ'I Washington State Department of Transportation


TWO-WAY TWO-LANE LEFT TURN ROADWAY

NOTES

6' TO 12'

....1
....1

1. For sign installation details, see Std. Plan G - series.

c
c

6' TO 12'

::::i

MIN.

PRIMARY
SIGN

LL

SHOULDER

2.

2'

SHOULDER

6' TO 12'

0:::
w

SHOULDER
SIGN

6' MIN.

SIGN

I -

I
EDGE OF

EDGE OF
TRAVELED
WAY

SUPPLEMENTAL
PLAQUE

WAY

c-

I_....;>

3. The "V" height for signs, with an area of more than


50 square feet and two or more sign supports, is
7 feet in both rural and urban areas.

EDGE OF
TRAVELED
WAY
EDGE OF SIGN SHALL
NOT INTRUDE ON EDGE
OF SIDEWALK

C'

II
II
II
II
II

~TRAVELED
I

c:;-

In rural areas, the "V" Height can be a minimum


of 7 feet for primary signs and 6 feet for the
supplemental plaques for greater visibility,
as directed by the engineer.

T
v

SIGN INSTALLATION
(FILL SECTION)

CURB
FACE

CURB
FACE

CURB

CURB

SIGN INSTALLATION
(CURB SECTION)

SIGN INSTALLATION
(SIDEWALK AND CURB SECTION)
HEIGHT V
TO BOTTOM OF SIGN
(NO SUPPLEMENTAL
PLAQUE)

TO BOTTOM OF
SUPPLEMENTAL PLAQUE
(WHEN REQUIRED)

RURAL

5' MINIMUM

4' MINIMUM

URBAN

7' MINIMUM

6' MINIMUM

6' TO 12'
6' TO 12'
6' TO 12'
SHOULDER
SHOULDER
SHOULDER

6' MIN.

PRIMARY
SIGN

3' MIN.

EDGE OF
TRAVELED
WAY

FACE OF BARRIER
OR GUARDRAIL

6' MIN.

6' MIN.

SIGN

___sC'

II
II
II
II
II

EDGE OF
TRAVELED
WAY

4'

. c-

0" MIN.

_....;>

3" MAX.l

SUPPLEMENTAL
PLAQUE

SIGN

MIN.
EDGE OF
TRAVELED
WAY

"

II
II
II
II
II

CLASS A
CONSTRUCTION SIGNING
INSTALLATION
STANDARD PLAN K-80.10-00

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SIGN INSTALLATION
(BEHIND TRAFFIC BARRIER)

SIGN WITH SUPPLEMENTAL


PLAQUE INSTALLATION
(FILL SECTION)

SIGN INSTALLATION
(DITCH SECTION)

....

Ken L. Smith
STATE DESIGN ENGINEER

02-21-07
DATE

fJ'I Washington State Department of Transportation

NOTES

USE ATTACHMENT DETAIL


OR
ATTACHMENT DETAIL

4' - 0" MIN. - 8' - 0" MAX.

0
0

I"(TYP)

1. All fasteners may be zinc plated, galvanized or stainless steel. All


steel angle and tubular steel shall be hot-rolled, high carbon steel,
painted or galvanized.

2'- 6"

TOP OF BARRICADE
SUPPORT ANGLE

5'- 0"

ELEVATION
WARNING LIGHT ATTACHMENT DETAIL

WARNING LIGHT
ATTACHMENT

-1

SIDE

TYPE 3 BARRICADE

2.

Install one lightweight Type A Low-Intensity flashing warning light


on the traffic side of the barricade. Install two Type A Low-Intensity
flashing warning lights per barricade when the barricades are used
to close a roadway. Attach the light to the barricade according to
the light manufacturer's recommendations or use the details shown
on this plan.

3.

Stripes on barricade rails shall be alternating orange and white


retroreflective stripes (sloping downward at an angle of 45 degrees
in the direction traffic is to pass).

4.

The Type 3 barricade design shown on this plan meets the crash
test requirements of NCHRP 350. Alternative designs may be approved if they conform to the NCHRP 350 crash test criteria and
the MUTCD.

5. When a sign is mounted on the barricade, it shall be securely bolted


to at least two plywood panels. The top of the sign shall not be
higher than the top panel of the barricade.
6. When sandbags are used in freezing weather, Urea fertilizer shall be
mixed with the sand in a quantity to prevent the sand from freezing.

6" )( 1 1/2" )( 1 1/2" )( 1/8"


STEEL ANGLE

STEEL ANGLE

DRILL TWO 1/2" DIAM. HOLES THROUGH


BARRICADE SUPPORT ANGLE

DRILL THREE
1/2" DIAM. HOLES

(1} 318"- 16 )( 1"


STEEL HEX BOLT

8" )( 2" )( 2" )( 1/8"


TUBULAR STEEL
ORANGE AND WHITE
REFLECTIVE SHEETING
ASTM D4956 - TYPE lii
OR Til (SEE NOTE 3}

(1) 3/8"- 16 )( 1 3/4"


STEEL HEX BOLT
(2) 1" FLAT WASHERS

(2) 1" FLAT WASHERS

(1} 3/8"- 16 STEEL


HEX NUT (TYP.)

(1} 318"- 16 STEEL


HEX NUT

(1) 3/8"- 16 )( 3"


STEEL HEX BOLT

ANGLE RESTS ON
TOP OF BOLT

(1} LOCKWASHER

(2} 1" FLAT WASHERS

ATTACHMENT DETAIL

FRONT OF
BARRICADE

SEE NOTE 2

TOP OF BARRICADE
SUPPORT ANGLE

1 1/2" )( 1 1/2" )( 1/8"


STEEL ANGLE
4'- 11" LONG (TYP.)

(1) 3/8"- 16 STEEL HEX NUT

3/4" ACX PLYWOOD PANEL

DETAIL

WARNING LIGHT
ATTACHMENT

6" x 2" x 2" x 1/8" TUBULAR


STEEL WITH PRE-DRILLED
HOLES

SANDBAGS AS REQUIRED
TO STABILIZE BASE
-ALL LEGS

TOP OF BARRICADE
SUPPORT ANGLE

1 1/2" )( 1 1/2" )( 1/8"


STEEL ANGLE
5' - 0" LONG (TYP.)

DRILL TWO 1/2" DIAM. HOLES THROUGH


BARRICADE SUPPORT ANGLE

TYPE 3 BARRICADE

(1) 3/8"- 16 )( 3"


STEEL HEX BOLT
(2) 1" FLAT WASHERS
(1) 3/8"- 16 STEEL
HEX NUT

STANDARD PLAN K-80.20-00


8" x 2" x 2" x 1/8" TUBULAR STEEL

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

ISOMETRIC VIEW

ATTACHMENT DETAIL

Kevin J. Dayton

VI
......

12-20-06

STATE DESIGN ENGINEER

DATE

Washington State Department o Transportation

WORK AREA

USEABLE TRAFFIC LANE

AREA CLOSED TO TRAFFIC

.
b
.
,Z
b
~
.,....

TYPE 3L BARRICADE

TYPE 3R BARRICADE

TYPE 3L BARRICADE

(
STRIPES ON THE BARRICADES SHALL SLOPE
DOWNWARD IN THE DIRECTION TRAFFIC IS TO PASS

AREA CLOSED TO TRAFFIC

ROAD CLOSURE AT INTERSECTION

USEABLE TRAFFIC LANE

WORK AREA

TYPE 3R BARRICADE

TYPE 3L BARRICADE

TYPE 3 BARRICADE

TYPE 3R BARRICADE

STANDARD PLAN K-80.20-00


ROAD CLOSURE AT OTHER LOCATIONS

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

BARRICADE PLACEMENT

.....

Kevin J. Dayton
STATE DESIGN ENGINEER

fJ'I Washington

12-20-06
DATE

State Department of Transportation

=12' - 6"

UNIT (SECTION) LENGTH

1/4" DRAFT

2" DIAM. PINNING HOLE (TYP.)

NOTES

2 # 4 (PAIR) (TYP.)

- WHEN REQUIRED

1/4" DRAFT

1. The reinforcing steel details for the NARROW BASE barrier are
the same as those shown for the 2' wide barrier except that the
bars along the vertical face run vertically with a 1 1/2" clearance.
2. The vertical dimensions for the slots and loop bar locations on
the NARROW BASE barrier are the same as those shown on the
END views of the 2' wide barrier.

2 318" (TYP.)

2 3/8" (TYP.)

TOP

1 # 4 (TYP.)

# 4 (PAIRS)- 6 SPACES@ 1'- 8 1/2"

1-'------'-t-'--------'-1 . - . - . - . - =- -~
......

C\1

Co

Co

.....

"'&>"

--------------------------

l;;r
.;;_) .

3/4" DIAM. LOOP BAR (TYP.)


C<>

2'- 0~~1-1/2~..-><-5~1/2"
i-'"_j----c.:_____
i
CONTINUOUS

:= 3' - 7 1/2"
(TYP.)

SIDE
2'- 0"

3/4" CHAMFER
(TYP.)

KEYWAY

END

y
1

3/4" CHAMFER
(TYP.)

..

END

2" 1/8"

v================t

9 1/2"
TOP

2 3/8"

CD # 4 (TYP.)
#4 (PAIR)

4" (TYP-.)--+-+---

=~V___:l

j~

r-

1-

2'- 9"

~I

CONNECTING PIN SEE STD. PLAN C-8

1 1/4" DRAFT (TYP.)


1/2"
I

3/4" DIAM.
LOOP BAR

SIDE

ALTERNATIVE LOOP BAR


3/4" DIAM. (ASTM A 36)
HOT DIP GALVANIZE AFTER
FABRICATION (ASTM A 123)

2" DIAM. PINNING


Co

'

HOLE (TYP.)
- WHEN REQUIRED

SEE STD. PLAN C-8e


FOR ANCHOR DETAILS

~~~--="~J
1'- 4 3/4"
END

NARROW BASE

1 1/2" )( 5 1/2"
CONTINUOUS
KEYWAY

3/4" DIAM.
LOOP BAR

TOP

END DETAIL
JOINING TWO BARRIER SEGMENTS

8"(TYP.)

SECTION

SECTION

ALTERNATIVE
TEMPORARY CONC. BARRIER
(F-SHAPE)
STANDARD PLAN K-80.30-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Ken L. Smith
STATE DESIGN ENGINEER

fJ'I Washington

02-21-07
DATE

State Department of Transportation

3"

II
PL 3/8

3/4" EXPANSION BOLT~J

"
1112

13/16" DIAM.

"

NOTES

SHIM - SEE NOTE 3

0'-5 1/2

1. Use Type 1 Anchors when the concrete pavement or bridge deck is 6" or thicker
with 2' wide concrete barrier only. Use Type 2 Anchors (Standard Plan K-80.37)
with narrow base barrier.

13/16" DIAM HOLE

13/16" DIAM. HOLE

L3

3/8

0'-8

I.

1 ..

8"

.. :I

I
v

3.

Use shims to properly fit the Type 1 Anchors to the barrier and roadway surfaces.

4.

Upon removal of the Type 1 Anchors, clean the bolt holes and fill them with grout
according to Standard Specification 6.02.3(20).

8"

5.

Remove the Type 3 Anchors by first driving the steel pins down through the barrier
further into the pavement to allow lifting the barrier without interference, then remove the pins from the pavement.

2. Adjust the location of the Type 1 Anchors to avoid the main reinforcing in the deck
when drilling holes.

4"
3/4" EXPANSION BOLT WI
HARDENED WASHER (TYP.}
- 4 1/2" MIN. EMBEDMENT

ATTACHMENT "A" DETAIL

6. After removing the Type 3 Anchors, clean the pin holes and fill them with sealant
according to Standard Specification 9-04.2.

ATTACHMENT "B" DETAIL

PROTECTED
WORK AREA
TRAFFIC
SIDE

EDGE OF DECK
9" MIN

ATTACHMENT "A"
-SEE DETAIL

ATTACHMENT "B"
-SEE DETAIL

PCCP

TRAFFIC
SIDE

TRAFFIC
SIDE

OR

1/2 SEGMENT LENGTH

2'- 1"
ATTACHMENT "A"
-SEE DETAIL

ATTACHMENT "A"
-SEE DETAIL

PCCP

ATTACHMENT LOCATION
(TYP.) - SEE NOTE 2

I>.

'

PRECAST CONCRETE
BARRIER SECTION (TYP.)

PLAN VIEW

TYPE 1 ANCHOR
ATTACHMENT LOCATIONS

SECTION VIEWS
(F-SHAPE SHOWN)

TYPE 1 ANCHOR

TYPE 1 ANCHOR

TEMPORARY INSTALLATION OF
PRECAST CONC. BARRIER TYPE 2 (STD. PLAN C-8) AND
TEMPORARY CONC. BARRIER (F-SHAPE) (STD. PLAN K-80.30}
ON CEMENT CONC. PAVEMENT OR BRIDGE DECK

ATTACHMENT LOCATIONS

TRAFFIC
SIDE

PROTECTED
WORK AREA
~

TRAFFIC
SIDE

TRAFFIC
SIDE

PRECAST CONCRETE
BARRIER SECTION (TYP.}

2" DIAM. PINNING


HOLE (TYP.)

so
(TYP.)
HMA

HMA

PINNING HOLE (TYP.}- ONLY REQUIRED


ON TRAFFIC SIDE(S) OF BARRIER

{9,,

lWO PINS REQUIRED


ON THE TRAFFIC SIDE
- lWO PINS TOTAL,
PER BARRIER SECTION

1" DIAM. X 30"


GALVANIZED STEEL PIN
(TYP.)

:J
SECTION VIEWS
(F-SHAPE SHOWN)

TYPE 3 ANCHOR
PIN LOCATIONS

lWO PINS REQUIRED


PER TRAFFIC SIDE
- FOUR PINS TOTAL,
PER BARRIER SECTION

TYPE 3 ANCHOR
TEMPORARY INSTALLATION OF
PRECAST CONC. BARRIER TYPE 2 (STD. PLAN C-8} AND
TEMPORARY CONC. BARRIER (F-SHAPE) (STD. PLAN K-80.30}
ON HOT MIX ASPHALT PAVEMENT

TEMPORARY CONC. BARRIER


ANCHORING

PLAN VIEW

STANDARD PLAN K-80.35-00

TYPE 3 ANCHOR

SHEET 1 OF 1 SHEET

PIN LOCATIONS

APPROVED FOR PUBLICATION

.....

Ken L. Smith
STATE DESIGN ENGINEER

fJ'I Washington

02-21-07
DATE

State Department of Transportation

NOTES
3

3/4" EXPANSION BOLT WITH


HARDENED WASHER (TYP.) \

FOR CLASS 1:
PL 1/2 X 3 X 0'-5 1/2

II

FORCLASS2:
PL 3/8 X 3 X 0'-5 1/2

~,\

11/2"
13/1S" DIAM.

"

SHIM - SEE NOTE 4

1. The intended use of this plan is for the temporary installation of Alternative
Temporary Concrete Barrier (F-Shape), Narrow Base (see Standard Plan
K-80.30) on cement concrete pavement or bridge deck.

FOR CLASS 1:
1 1/1S" DIAM. HOLE

~rt

FORCLASS2:
13/1S" DIAM. HOLE

2.

Use Class 1 when the concrete pavement or bridge deck is 9" or thicker;
use Class 2 when it is 6" or thicker.

[>

FOR CLASS 1:
1 1/1S" DIAM. HOLE

(),

FORCLASS2:
13/1S" DIAM. HOLE

3"

3. Adjust the location of the anchors to avoid the main reinforcing in the deck
when drilling holes.

FOR CLASS 1:
L 3 X 3 X 1/2 X 0'-8

.. :

I.

8"

FORCLASS2:
L 3 X 3 X 3/8 X 0'-8

according to Standard Specification 6.02.3(20).

[>

FOR CLASS 2:
3/4" EXPANSION BOLT WITH
4 1/2" MIN. EMBEDMENT

8"

ATTACHMENT "B" DETAIL

SEGMENT LENGTH = L

us

TRAFFIC
SIDE

U3

us

U3

PROTECTED
WORK AREA

OR

(),

"'

EDGE OF DECK

t>

"'

ATTACHMENT LOCATION
(TYP.) - SEE NOTE 3

(),

NARROW BASE, ALTERNATIVE


TEMPORARY CONC. BARRIER

Use shims to properly fit the anchors to the barrier and roadway surfaces.

5. Upon removal of the anchors, clean the bolt holes and fill them with grout
4"

FOR CLASS 1:
1" EXPANSION BOLT WITH
S" MIN. EMBEDMENT

ATTACHMENT "A" DETAIL

4.

"'

"'

t>

CLASS 1: S" MIN.

TYPE 2 ANCHOR: CLASS 1

CLASS 2: 9" MIN.

"'

NARROW BASE, ALTERNATIVE TEMPORARY


CONCRETE BARRIER SEGMENT

PLAN VIEW

ATTACHMENT LOCATIONS

(),
~

ATTACHMENT "A"
-SEE DETAIL

t>

ATTACHMENT "B"
-SEE DETAIL

(),

PCCP

(),

t>

SEGMENT LENGTH = L

"'

"'

U4

U4

U4

"I"

U8

(),

TEMPORARY CONC. BARRIER


ANCHORING - NARROW

SECTION VIEW

TYPE 2 ANCHOR: CLASS 1 & 2


ATTACHMENT LOCATIONS

ATTACHMENT LOCATION
(TYP.) - SEE NOTE 3

PLAN VIEW

NARROW BASE, ALTERNATIVE TEMPORARY


CONCRETE BARRIER SEGMENT

STANDARD PLAN K-80.37-00


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

TYPE 2 ANCHOR: CLASS 2


ATTACHMENT LOCATIONS

.....

Ken L. Smith
STATE DESIGN ENGINEER

fJ'I Washington

02-21-07
DATE

State Department of Transportation

1000' MAX. TO PULL POST


2STRAND
BARBED WIRE

WIRE CINCH
STAY(TYP.)

.:\

14' - 0" MAX

14' - 0" MAX

NOTES

END, CORNER,
ORGATE POST

1. The bracing and pull post details for Wire Fence Type 2 are the same as for Type 1.

I
i
i

FT

-:;:;

II

2. Attach the wire mesh to the posts using four fasteners. Three additional fasteners per
post are required within and at the limits of sag conditions. Use additional fasteners
on posts that mark the angle point of any sudden change in topography.

_j1
~

'

3. See Standard Specification 9-16.2(1) for wood post sizes. Wood anchors (for wood
posts) shall be 2 x 41umber, 12" long minimum, and fastened with three 16d galvanized
nails.

"'"

_L

ll

'/

c:

c:

LINEPOST ~

WIRE MESH']

18" SQUARE
(TYP.)

WI ANCHOR

832-S-12-1/2

PLATE (TYP.)

so MIN./7///)(//.- v! !
] ~ ..
.::
ss MAX. t

&,
'

c-.

v.lJ~

BRACE (TYP.)

.____

1. 12" ROUND

WIRE FENCE TYPE 1

(TYP.)

(STEEL POSTS SHOWN)


1000' MAX. TO PULL POST
14' - 0" MAX

WIRE CINCH ~l
STAY(TYP.)

~l_

i
i
i

2 STRAND BARBED WIRE


(TYP.)- SPACED@ 12"

]__!1_
~

c:

so MIN.
ss MAX.

"--.....

END, CORNER,
ORGATE POST

14' - 0" MAX

c:

LINE POST WI ANCHOR


PLATE (TY P. )

..

~==-:.~

..

18" SQUARE
(TYP.)

~
~

&,
'

"'"

;----

'l~m

so MIN .
ss MAX.

CORNER BRACING

vi j

:1::.!.

INTERSECTION BRACING

(SHOWN FOR WIRE FENCE TYPE 1)

&,
'

(SHOWN FOR WIRE FENCE TYPE 1)

c-.

VJL

L:....L..

1. 12" ROUND

WIRE FENCE TYPE 2

(TYP.)

(STEEL POSTS SHOWN)

14'- 0" MAX.


ADDITIONAL FASTENERS
-SEE NOTE2

'I f:~-~;rm
~

']

///;<.,

~J i rN//

Jl;

so MIN.
ss MAX.

:4!

so MIN.
ss MAX.

-~~-=:t

li2J

INTERMEDIATE BRACING/PULL POST

GRADE DEPRESSION (SAG) DETAIL

(SHOWN FOR WIRE FENCE TYPE 1)

(STEEL POSTS SHOWN)

STEEL POSTS AND BRACES


POST SPECIFICATIONS
-.----PIPE
POST

END, CORNER, OR PULL POST

LINE OR BRACE POST

NOM. SIZE
(SCH. 40)
I. D.
2"DIAM.

2"DIAM.

ROLL FORMED

SECTION

I
p

T-POST

WEIGHT
(lb/ft)

WEIGHT
(lb/ft)

5.10

1.85

3 1/2"

1.33

~
.....
('I)

-~
FABRICLOOP7
-2SIDES

II

cc

FENCE LINE

WIRE FENCE TYPES 1 & 2


AND WIRE GATES
STANDARD PLAN L-10.10-02
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

8'- 0"
END CORNER
'
OR GATE
POST'
SEE NOTE3

i
i
i

I
,__

LINE POST SPACING


@ 14'- 0" CENTERS

BRACE POST
-SEE NOTE 3
WOOD BRACE
- SEE NOTE 3 --:\

8'- 0"
BRACE POST
-SEE NOTE3

i
i
i

8' -0"
BRACE POST
-SEE NOTE3

PULL POST - SPACED


@ 1000' MAX. - SEE NOTE 3

WOOD BRACE (TYP.)


-SEE NOTE 3

~~-*.....

BRACE POST (TYP.)


-SEE NOTE 3
WOOD BRACE (TYP.)
-SEE NOTE 3

__;;-i'o

...-

"""

.....

'"'""'

~:

_l_

i'oj

Cv>

...- ~

~BRACE

1_[
t

p
WIRE

WOOD ANCHOR (TYP.)


-

i'o

i'of

l:l

WOOD ANCHOR (TYP.)


-SEE NOTE3

'

-t

BRACE WIRE (TYP.)

BRACE POST
-SEE NOTE3

4" (TYP.)

END BRACING

INTERMEDIATE BRACING/PULL POST

(WIRE FENCE TYPE 1 SHOWN)

(WIRE FENCE TYPE 1 SHOWN)

WOOD BRACE
-SEE NOTE 3

8'- 0"
BRACE POST
-SEE NOTE
3\i

WOOD BRACE
-SEE NOTE3

...- "'\

I-

1--

--

(WIRE FENCE TYPE 1 SHOWN)

i
r-'

~,__
i'o

CORNER BRACING

GATE POST
-SEE NOTE3

_;..;--- r--

r--.

=~ - ~

i'o

==
J

BRACE WIRE\'

WOOD ANCHOR (TYP.) ~

'--

GATE BRACING

SINGLE WIRE GATE 14FT. WIDE- PAY LIMIT

- PAY LIMIT

10'- 0"

FRAMENPC1"PIPE

r-

BRACE (TYP.)
NPC 1" PIPE

........

BRACE [TYP. I
'

1-"1:

10'- 0"

FRAME (TYP.)
- NPC 1" PIPE

GATE POST (TYP.)

~ All-+-+-1-+-+-+-ll-+ll+-+-ll-+-+-+f'-+-+;.....---+=ll~;...--=--+--+--+--+-+-;.....-+-ll ~
"""

(WIRE FENCE TYPE 1 SHOWN)

DOUBLE WIRE GATE 20FT WIDE

14'- 0"
BRACE (TYP.)
- NPC 1" PIPE

INTERSECTION BRACING

WOOD POSTS AND BRACES

(WIRE FENCE TYPE 1 SHOWN)

"""

f-0'

f'

I'""'

.......

.......

......

"

GAT E POST (TYP.)

l[kJ1

..... "'""'

......

"""

jTJ
~ . !!
!p
ii:
'!!

f<

\ ..... TRUSS ROD -

,if

\__ 3/8" DIAM.

,..

TRUSS ROD (TYP.)7


- 3/8" DIAM.

" tt~'

12" SQUARE

:~.
~

(STEEL POSTS SHOWN)

WIRE FENCE TYPES 1 & 2


AND WIRE GATES
STANDARD PLAN L-10.10-02
SHEET 2 OF 2 SHEETS

!.

]]
::
~!

APPROVED FOR PUBLICATION

. 11U.

DOUBLE GATE
(STEEL POSTS SHOWN)

GATES

~~

. !!

::

SINGLE GATE

1!:~-~

BRACE (TYP.)

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

NOTES
1000' MAX.

10' MAX.
TENSION WIRE

END OR CORNER {BRACE) POST

LINE POST - SPACED

PULL POST

TENSION WIRE

PULL POST - SPACED


@ 1000' MAX.

HOG RINGS {TYP.)


SPACED @ 24" MAX.

TENSION WIRE

@ 10'MAX.

1. All concrete post bases shall be 10"


minimum diameter.

BRACE POST

3. Details are illustrative and shall not


limit hardware design or post selection of any particular fence type.

II

(.9

= iii
O
I

-'

2. Along the top and bottom, using Hog


Rings, fasten the Chain Link Fence
Fabric to the Tension Wire within the
limits of the first full fabric weave.

(.)

<00::

TIE WIRES {TYP.)SPACED @ 14" MAX.

STRETCHER
BAR
KNUCKLED SELVAGE
{TYP.)

TENSION WIRE
HOG RINGS (TYP.)
SPACED @ 24" MAX.

..

CHAIN LINK
FENCE FABRIC

TENSION WIRE

POST

CONCRETE POST
BASE {TYP.)

FABRIC BANDSPACED 15" MAX.

TYPE3
500' MAX.

10' MAX.
TENSION WIRE

END OR CORNER {BRACE) POST


TENSION WIRE

10' MAX. {TYP.)

LINE POST- SPACED


@ 10'MAX.

PULL POST

HOG RINGS {TYP.)


SPACED @ 24" MAX.
TENSION WIRE

BRACE POST

METHOD OF FASTENING
STRETCHER BAR TO POST

II

(.9

= iii
OI

-'

(.)

""a::
~

KNUCKLED SELVAGE
(TYP.)

CHAIN LINK
FENCE FABRIC

CONCRETE POST
BASE (TYP.)

TYPE4
3 1/2"

POST AND RAIL SPECIFICATIONS

PIPE
POST

END, CORNER, OR PULL POST

LINE OR BRACE POST

NOM. SIZE
{SCH. 40)
I. D.
21/2" DIAM.

2"DIAM.

1 5/8"

ROLL FORMED

SECTION

8
0

WEIGHT
{lb/ft)

C"l

~~c

FABRIC LOOP
-2SIDES

78
Y

CHAIN LINK FENCE


TYPES 3 AND 4
STANDARD PLAN L-20.10-02
SHEET 1 OF 2 SHEETS

-'-------'

5.10

1.85

=::::::::

~
......

APPROVED FOR PUBLICATION


FENCE LINE

Pasco Bakotich Ill

-~------S~T~M~E~DE~SI~GN~E~NG~IN~E=ER~----

06121112
DATE

. . . Washington State Department of Transportation

EYE BOLT

EYE NUT
EYE BOLT

~+

TURNBUCKLE

TENSION WIRE

-r--- r--------'--"'"""
STRETCHER BAR

FABRIC BAND

TENSION WIRE

FABRIC BAND (TYP.)

STRETCHER BAR (TYP.)


END OR CORNER (BRACE) POST

DETAIL

PULL POST (AT END OR CORNER)

DETAIL

TENSION WIRE

TIE WIRE -SPACED


@ 14" MAX. (TYP.)
EYE BOLT
EYE NUT
TURNBUCKLE
TURNBUCKLE
TENSION WIRE
TENSION WIRES

EYE BOLT

HOG RING -SPACED


@24"MAX.
FABRIC BAND (TYP.)

STRETCHER BAR (TYP.)


BRACE POST

DETAIL

CHAIN LINK FENCE


TYPES 3 AND 4

PULL POST (WITHIN RUN)

DETAIL

STANDARD PLAN L-20.10-02


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

CHAIN LINK FENCE TYPE 3 OR 4


PAY LIMIT

rn
z
w

I
I

HOG RINGS - SPACED


@ 24" MAX. (TYP.)

PULL POST

0::

III

I CHAIN LINK FENCE TYPE 3 OR 4

DOUBLE 14 FT. CHAIN LINK GATE- PAY LIMIT


DOUBLE 20 FT. CHAIN LINK GATE- PAY LIMIT

14'- 0" OR 20'- 0"

PAY LIMIT

10'- 0" (TYP.)

~--------------------------~~1----------~------~
TIE WIRES (TYP.) SPACED@ 14" MAX.

GATE POST (TYP.) - 3 1/2"


DIAM. (NOM., SCH. 40)

MATCH FENCE
SELVAGE (TYP.)

TENSION WIRE

PULL POST
TOP HINGE- 180"
SWING (TYP.)

TENSION WIRE

TENSION WIRE

....1
....1

iii

FABRIC BAND (TYP.)

STRETCHER BAR (TYP.)

BOTTOM TENSION WIRE


(TYP.) (NOT REQUIRED FOR
CHAIN LINK FENCE TYPE 4)

BOTTOM HINGE -

MATCH FENCE
SELVAGE (TYP.)

180" SWING (TYP.)

CHAIN LINK FENCE FABRIC


3' - 0" - CHAIN LINK FENCE TYPE 3
2' - 0" - CHAIN LINK FENCE TYPE 4

12" ROUND (TYP.)

DOUBLE GATE

' ' CHAIN LINK FENCE TYPE 3 OR 4 '


PAY LIMIT

PULL POST

I'

' I ' CHAIN LINK FENCE TYPE 3 OR 4 ' '

SINGLE 6 FT. CHAIN LINK GATE


PAY LIMIT

HOG RINGS - SPACED


@ 24" MAX. (TYP.)

6'- 0"
GATE POST (TYP.)- 3 1/2"
DIAM. (NOM., SCH. 40)

TENSION WIRE

10'- 0" (TYP.)


TENSION WIRE FOR GATE POST
- REQUIRED ONLY ON HINGE SIDE

TOP HINGE90" SWING

PAY LIMIT

.I
PULL POST
TENSION WIRE

FABRIC BAND (TYP.)

STRETCHER BAR (TYP.)

BOTTOM TENSION WIRE


(TYP.) (NOT REQUIRED FOR
CHAIN LINK FENCE TYPE 4)

CHAIN LINK GATE


HOG RINGS - SPACED
@ 24" MAX. (TYP.)

CHAIN LINK FENCE FABRIC


3' - 0" - CHAIN LINK FENCE TYPE 3
2' - 0" - CHAIN LINK FENCE TYPE 4

TIE WIRES (TYP.) SPACED @ 14" MAX.

12" ROUND (TYP.)

STANDARD PLAN L-30.10-01


SHEET 1 OF 2 SHEETS

SINGLE GATE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....
VI

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

en
z

w
w

a:

EYE NUT

[I]

EYE BOLT

....1
....1

TURNBUCKLE

TENSION WIRE

iii

TENSION WIRE

FABRIC BAND

TENSION WIRE

Cl

TOP HINGE

STRETCHER BAR

STRETCHER BAR (TYP.)

GATE POST

DETAIL

PULL POST

DETAIL

STRETCHER BAR (TYP.)


STRETHCER BAR

FABRIC BAND (TYP.)

FABRIC BAND
TENSION WIRE
TENSION WIRE

TURNBUCKLE
TURNBUCKLE
TENSION WIRE (TYP.) (NOT
REQUIRED FOR CHAIN LINK
FENCE TYPE 4)

BOTIOM HINGE

TENSION WIRE (TYP.) (NOT


REQUIRED FOR CHAIN LINK
FENCE TYPE 4)

EYE NUT

CHAIN LINK GATE


GATE POST

DETAIL

PULL POST

DETAIL

STANDARD PLAN L-30.10-01


SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-16-11
DATE

Washington State Department of Transportation

12'- 6" MAX.


END OR CORNER
(BRACE) POST SEE DETAIL

300' MAX.

HOG RINGS (TYP.)SPACED @ 24" MAX.

12' -6" MAX.


BRACE POST

PULL POST

TENSION WIRE (TYP.)

TIE WIRES (TYP.)SPACED@ 14" MAX.

PULL POSTSEE DETAIL

TENSION WIRE (TYP.)

TENSION WIRE

TENSION WIRE

FABRIC BAND (TYP.)SPACED@ 12" MAX.

NOTES

1. All glare screen posts shall be 2 1/2" I.D.


galvanized steel.
2. Wood blocks shown. Blocks of alternate
material may be used. Wood blocks shall
be toe-nailed to post with 16d galvanized
nails to prevent block rotation. See
Standard Specification 9-16.3(2).

GLARE SCREEN FABRIC 1" DIAMOND WIRE MESH

3. Attach blocks to steel posts using bolt


holes on approaching traffic side of post
web.
4. See Standard Plan C-1 b for posts and
wood block details.

BEAM GUARDRAIL

ELEVATION VIEW
TENSION WIRE (TYP.)
51/4"

POST - SEE NOTE 1


1/2" DIAMETER
U-BOLT
1/2" DIAMETER
U-BOLT

3 5/8"

TURNBUCKLE

EYE BOLT

5/8" DIAMETER
HOLE (TYP.)

TENSION WIRE (TYP.)


1/2" HEAVY HEX NUT

3"

1/2" HEAVY HEX NUT


1/2" EYE NUT
1/2" EYE NUT
STRETCHER BAR (TYP.)
STEEL BODY PLATE SEE DETAIL

POSTSEE NOTE 1

STEEL BODY PLATE SEE DETAIL

POST - SEE NOTE 1

16d ANTI-ROTATION NAIL


(TYP.)- SEE NOTE 2

FABRIC BAND (TYP.) SPACED@ 12" MAX.


STEEL BODY PLATE

16d ANTI-ROTATION NAIL


(TYP.)- SEE NOTE 2
PULL POST (WITHIN RUN)

VIEW0

VIEW0
DETAIL

......-

16d ANTI-ROTATION
~ NAIL (TYP.)- SEE NOTE 2

........

16d ANTI-ROTATION
~ NAIL (TYP.)- SEE NOTE 2

WOOD BLOCK (TYP.)SEE NOTE4

WOOD BLOCK (TYP.)SEE NOTE4

STEEL POST - SEE NOTE 1


STEEL POSTSEE NOTE 1
STEEL POSTSEE NOTE4

GLARE SCREEN TYPE 1


DESIGN A

NAIL DRIVEN INTO WOODEN POST


FOR STEEL POST SUPPORT

STANDARD PLAN L-40.10-02

WOOD POSTSEE NOTE4

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

END OR CORNER (BRACE) POST


WITH STEEL POST
DETAIL

END OR CORNER (BRACE) POST


WITH EXISTING WOOD POST
DETAIL

ISOMETRIC VIEW

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

3/8" EYE BOLT (TYP.)


WITH HEX NUT AND WASHER

3/8" EYE NUT (TYP.)

3/8" EYE BOLT (TYP.)


TURNBUCKLE

TENSION WIRE

FABRIC B ND
( P.)

TENSION WIRE

STRETCHER BAR (TYP.)


STRETCHER BAR (TYP.)

b
'

TENSION WIRE

TENSION WIRE (TYP.)

TURNBUCKLE
U-BOLT (TYP.)
-SEE DETAIL A
i--

=
.....

5/8" EYE NUT WITH WASHER

GUARDRAIL POST
(STEEL SHOWN)

GUARDRAIL POST
(STEEL SHOWN)

.1::::::::::::::::\:::{.pn
i

!
END OR CORNER (BRACE) POST DETAIL

i ~--'-

PULL POST (WITHIN RUN) DETAIL

GLARE SCREEN TYPE 1


DESIGN A
STANDARD PLAN L-40.10-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

10' MAX.

150' MAX.
TENSION WIRE

(f)

w
w

END OR CORNER
(BRACE) POST

0:::
ID

PULL POST

LINE POST- SPACED


@ 10' MAX.

PULL POST- SPACED


@ 150" MAX. (TYP.)

10' MAX. (TYP.)

HOG RINGS (TYP.)


SPACED @ 24" MAX.

BRACE POST

TENSION WIRE

BRACE POST

TENSION WIRE

...J
...J

iii

TIE WIRE (TYP.) SPACED@ 14" MAX.

1:I:

(!)

= iii
-' (.)

OJ:

coo::

Cl

FABRIC BAND (TYP.)

GLARE SCREEN FABRIC


- 1" DIAMOND WIRE MESH

ID

HOG RINGS (TYP.)


SPACED @ 24" MAX.

ELEVATION VIEW
EYE BOLT
LINE POST TOP

EYE NUT

EYE NUT

TURNBUCKLE
HOG RINGS (TYP.)
SPACED @ 24" MAX.

TENSION WIRE

TENSION WIRE
1111

TURNBUCKLE

SHACKLE (TYP.)

TENSION WIRE (TYP.)

TIE WIRE - SPACED


@ 14" MAX.

FABRIC BAND (TYP.)

STRETCHER BAR (TYP.)

STRETCHER BAR (TYP.)

PULL POST

PULL POST (WITHIN RUN)

LINE POST

DETAIL0

DETAIL0

DETAIL0

STRETCHER BAR (TYP.)


TENSION WIRE

HOG WIRE (TYP.)


SPACED @ 24" MAX.
TURNBUCKLE
TENSION WIRE (TYP.)
TENSION WIRE

FABRIC BAND (TYP.)

GLARE SCREEN TYPE 1


DESIGN B
STANDARD PLAN L-40.15-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

PULL POST

DETAIL0

BRACE POST

DETAIL0

Pasco Bakotich Ill

.....

STATE DESIGN ENGINEER

06-16-11
DATE

fll Washington State Department of Transportation

PULL POST- SPACED


150
' MAX.
HOG RINGS (TYP.)SPACED @ 24" MAX.

150' MAX.

10' MAX.

LINE POST- SPACED.

10' MAX. (TYP.)

@ 10'MAX.

PULL POST

END OR CORNER
(BRACE) POST

BRACE POST

BRACE POST

TIE WIRES (TYP.)SPACED@ 14" MAX.

GLARE SCREEN
FABRIC (TYP.)

;H:
;H:
.-li...
I!

TENSION WIRE
_ HOG RINGS (TYP.)SPACED @ 24" MAX.

ELEVATION VIEW
EYE BOLT

EYE NUT

TURNBUCKLE

HOG RINGS (TYP.)


SPACED @ 24" MAX.

TENSION WIRE
TENSION WIRE

TENSION WIRE
FABRIC BAND (TYP.)

GLARE SCREEN SLAT (TYP.)

TIE WIRE- SPACED


@ 14" MAX.

STRETCHER BAR (TYP.)


GLARE SCREEN SLAT (TYP.)
PULL POST

DETAIL

LINE POST

DETAIL

0
TENSION WIRE

EYE BOLT
EYE NUT

TIE WIRE- SPACED


@ 14"MAX.

TURNBUCKLE

GLARE SCREEN SLAT (TYP.)

EYE BOLT

TENSION
WIRE
3/8-16 x 5" GALVANIZED
EYE BOLT
TENSION WIRE

TENSION WIRE

TENSION WIRE
TURNBUCKLE
HOG RINGS (TYP.)SPACED @ 24" MAX.

GLARE SCREEN TYPE 2


(CHAIN LINK WITH SLATS)
STANDARD PLAN L-40.20-02
SHEET 1 OF 1 SHEET

STRETCHER BAR (TYP.)


GLARE SCREEN SLAT (TYP.)

APPROVED FOR PUBLICATION


PULL POST (WITHIN RUN)

DETAIL

BRACE POST

DETAIL

Pasco Bakotich Ill


------~=-~~~-------

.....

STATE DESIGN ENGINEER

06121112
DATE

. . . Washington State Department of Transportation

PLASTIC PIPE CAP (TYP.)

SIGN PANEL W12-502 SP


- 48" x 12" (TYP.)

en
z

w
w

a:

NOTE

5/8" DIAM. WIRE ROPE

[I]

Hardware shall be stainless steel or galvanized


in accordance with AASHTO M232 .

....1
....1

iii

YELLOW REFLECTIVE
TAPE- 3" (TYP.)

Cl

PADLOCK
-AGENCY PROVIDED

POST (TYP.)

C\1

TOP OF

j__ __~jC~C:~--------------------------------------------------~-~~~l____R_O_A_D_W_A_Y~~~=c~------1
I

I
.

I
I

I
I

: ! :

I
.

I
I

: ! :

~
I
I

::::

12'- 0"

~
I
I

ELEVATION

WOOD SPACER

r-

TIMBER POST
4 x 6 (NOM.)

16"

PLASTIC PIPE- 12" (NOM.) x 2'- 7" LONG


COLOR SHALL BE HIGHLY VISIBLE
(SAFETY YELLOW IS ACCEPTABLE)

TOP VIEW
(CAP NOT SHOWN)

END POST

TOP OF TIMBER POST

5/8" S.S. EYE STRAP - FASTENED TO


THE SIGN PANEL WITH 2 1/8" DIAM.
SCREWS AND 2 HEX NUTS (TYP.)

SIDE OPPOSITE
STRIPES

SIGN PANEL MOUNTING DETAIL

=611

EYE SCREW- 5/8" DIAM. x 6"


WITH 2" FLAT WASHER

HEX LAG BOLT - 3/8-?UNC x 5"


WITH 1" DIAM. FLAT WASHER
(4 SETS TOTAL)
1 1/2" DIAM. HOLE (TYP.)

ACCESS CONTROL GATE


STANDARD PLAN L-70.10-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SECTION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-21-08
DATE

Washington State Department of Transportation

PLASTIC PIPE CAP (TYP.)

SIGN PANEL W12-502 SP


- 48" X 12" (TYP.)

en
z

w
a:
w

5/8" DIAM. WIRE ROPE

MIDDLE POST
-REMOVABLE

SEE MOUNTING
DETAIL

YELLOW REFLECTIVE
TAPE - 3" (TYP.)

~~~...,..,., ____j_

""

~~~-......a-:::::3

[I]

....1
....1

iii

END POST

Cl

:::: 12'- 0"


I

ELEVATION
NOTE

r_

WOOD SPACER

WOOD SPACER

TIMBER POST
4 X 6 (NOM.)

TIMBER POST
-4 X 6 (NOM.)

Hardware shall be stainless steel or galvanized


in accordance with AASHTO M232.

J
PLASTIC PIPE - 12" (NOM.) x 2' - 7" LONG
COLOR SHALL BE HIGHLY VISIBLE
(SAFETY YELLOW IS ACCEPTABLE)

TOP OF TIMBER POST

J
PLASTIC PIPE- 12" (NOM.) x 2'- 7" LONG
COLOR SHALL BE HIGHLY VISIBLE
(SAFETY YELLOW IS ACCEPTABLE)

GALV. STEEL TUBE

TOP VIEW

TOP VIEW

(CAP NOT SHOWN)

(CAP NOT SHOWN)

END POST

MIDDLE POST

6"

EYE SCREW- 5/8" DIAM. x 6"


WITH 2" FLAT WASHER

: : : : 6"

TOP OF TIMBER POST

EYE SCREW- 5/8" DIAM. x 6"


WITH 2" FLAT WASHER (TYP.)

I.

...

16"

8" :.

5/8" S.S. EYE STRAP - FASTENED TO


THE SIGN PANEL WITH 2 1/8" DIAM.
SCREWS AND 2 HEX NUTS (TYP.)

16"

SIDE OPPOSITE
STRIPES

SIGN PANEL MOUNTING DETAIL

HEX LAG BOLT - 3/8-7UNC X 5"


WITH 1" DIAM. FLAT WASHER
(4 SETS TOTAL)

HEX LAG BOLT - 3/8-7UNC X 5"


WITH 1" DIAM. FLAT WASHER
(4 SETS TOTAL)

1 1/2" DIAM. HOLE (TYP.)

1 1/2" DIAM. HOLE (TYP.)

f7- TOP OF STEEL TUBE

~=====!=::::::::::::~
GALV. LAG SCREW- 3/8" DIAM. W/
FLAT WASHER (TYP.) (2 SETS REQ.)

I>

GALV. STEEL TUBE


- 3/16" X 4" X 6"

.I>

I>

ACCESS CONTROL
DOUBLE GATE

STANDARD PLAN L-70.20-01


COMMERCIAL CONCRETE

SECTION

18" DIAM

SECTION

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

05-21-08
DATE

Washington State Department of Transportation

r
~E

/=
I

/)

Cl

c:::

WHITE EDGE YELLOW EDGE


LINE
LINE

--

~=

LL.

>(.)

'~

LANE LINE

/_

RAMP

=II

I
~
~=1=:: --=

WIDE LANE LINE

"'

"'-"'
~R

=
=

==:I=

DOTTED LANE LINE

=
=

1". "' "'

~~1'-L

300' MIN.

,R

WHITE EDGE LINE

NOTES

YELLOW EDGE LINE

:J

:;..:

1. Where shown on the plans or specified in the Special Provisions, raised pavement
markers shall be used to supplement or substitute for the painted pavement markings
shown hereon. See the Standard Plans for RPM supplement and substitution patterns.

[I]

I
Cl

2. The channelization shown on this plan assumes optimal roadway geometric design.
The dimensions may vary to fit existing conditions. See Contract.

END OF TAPER
(SEE CONTRACT)
WHITE EDGE LINE

LEGEND

SINGLE-LANE ON-CONNECTION

LANE LINE

YELLOW EDGE LINE

WIDE LANE LINE

R RAMP LANE WIDTH


L = LANE WIDTH

WHITE EDGE LINE

~~-~~~~~~~
~

225' MIN.

=r~

YELLOW EDGE LINE

WHITE EDGE LINE

TYPE 5 TRAFFIC
ARROW (TYP.)
YELLOW EDGE LINE

LANE LINE
TRAFFIC ARROW TYPE MAY VARY- SEE
CONTRACT FOR TYPE SPECIFIED

1/2 MILE MIN.

~~~~~~~~p

50'

z
D

D:J
J:

~================~i
WIDE DOTTED
LANE LINE

LANE LINE

SINGLE-LANE OFF-CONNECTION

WHITE EDGE LINE

STOP LINE

1/2 MILE MIN.

::sao
LANE LINE

WIDE LANE LINE

p~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

J:

(.)

!;(~~~~~~~
~r-~~--~--~----------------------------------------~~~

YELLOW EDGE LINE

RAMP CHANNELIZATION
SINGLE LANE
STANDARD PLAN M-1.20-02
SHEET 1 OF 1 SHEET

WIDE LANE LINE

WIDE DOTTED LANE LINE

WHITE EDGE LINE

SINGLE-LANE OFF-CONNECTION
FOR ONE LANE REDUCTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

WHITE EDGE LINE

YELLOW EDGE LINE

LANE LINE

LANE LINE

WIDE LANE LINE

--

-DOTTED LANE LINE

~LANE LINE

Cl

0:::

LL.

>-

--

~
w
z

<..>

<(
(/)

::::i

::::i

::c

--

~~

<..>

YELLOW EDGE LINE

1'\...~R

:2:

~~

Cl

NOTES

~~DOFTAPER

\ _ WHITE EDGE LINE

(SEE CONTRACT)

TWO-LANE ON-CONNECTION

YELLOW EDGE LINE

1. Where shown on the plans or specified in the


Special Provisions, raised pavement markers shall
be used to supplement or substitute for the
painted pavement markings shown hereon. See
the Standard Plans for RPM supplement and
substitution patterns.
2. The channelization shown on this plan assumes
optimal roadway geometric design. The dimensions
may vary to fit existing conditions. See Contract.

LANE LINE
1/2 MILE MIN.

LEGEND

--

~~~~~~~~~~~~~~~~~~~

D~D

R = RAMP LANE WIDTH

z
~

=LANE WIDTH

::c

F=========================================~~
:2:
LANE LINE

WIDE DOTTED
LANE LINE

WHITE EDGE LINE

1/2 MILE MIN.

WHITE EDGE LINE

:::SOO'

225' MIN.

LANE LANE LINE

WIDE LINE

--

--

~~~~~~~~~~
w

::::i

::c

YELLOW EDGE LINE

i~--~~------------~
WHITE EDGE LINE

RAMP CHANNELIZATION
TWO LANE

WIDE LANE LINE

STANDARD PLAN M-1.40-02


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

WHITE EDGE LINE


LANE LINE

TWO-LANE OFF-CONNECTION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

f
=

I=

-------

---

l.

YELLOW EDGE LINE

/=

2,

LANE LINE

5 ' MIN.

-----

WIDE
DOTTED
LANE
LINE

7=
'""
"' "'

---

/
1'-

'-"'- I

LANE LINE

WIDE LANE LINE

=//=

WIDE LANE LINE

WHITE EDGE LINE

~C-DR

\.

'

=
=

WHITE EDGE LINE

~C-DR

600'

WIDE DOTTED LANE LINE

YELLOW EDGE LINE

300' MIN.

NOTES
0
0:::
0

LEGEND

1. Where shown on the plans or specified in the Special Provisions, raised pavement markers
shall be used to supplement or substitute for the painted pavement markings shown hereon.
See the Standard Plans for RPM supplement and substitution patterns.

11..

~
;;5

C-DR=

COLLECTOR DISTRIBUTOR RAMP LANE WIDTH

C-D L =

::::i

COLLECTOR DISTRIBUTOR LANE WIDTH

2. The channelization shown on this plan assumes optimal geometric design. The dimensions
may vary to fit existing conditions. See Contract.

R = RAMP LANE WIDTH


L = LANE WIDTH
YELLOW EDGE LINE

-----

I
2,

LANE LINE

-----

I
=

""'~

1'225' MIN.

;(
~ =

::::i
:I:

----- \

i ---

"'

~WIDE

""

"' ~~
"

LANE LINE

LANE LINE

2,

;(
=

-----

I"\..\__ WHITE EDGE LINE


225' MIN.

I"-

~C-DR

_\ \

~WIDE

COLLECTOR-DISTRIBUTOR ROAD OFF-CONNECTION

RAMP

_(

(.)

""
"'"'

!;(
:2

"'{C-D L

=rc-DL

RAMP CHANNELIZATION
COLLECTOR-DISTRIBUTOR
ROAD
STANDARD PLAN M-1.60-02
SHEET 1 OF 1 SHEET

------=
\

LANE LINE

:I:

) - WHITE EDGE LINE

---

=
ID
=
w

YELLOW EDGE LINE

WHITE EDGE LINE

....1

\ \

=I

\\
\ _ WHITE EDGE LINE

I
=

\\

YELLOW EDGE LINE

\ _ WHITE EDGE LINE

YELLOW EDGE LINE

\(

APPROVED FOR PUBLICATION

:Ie-DR

Pasco Bakotich Ill

YELLOW EDGE LINE

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

YELLOW EDGE LINE

LANE LINE

WIDE DOTTED LANE LINE

-YELLOW EDGE LINE


WHITE EDGE LINE

END OF TAPER
(SEE CONTRACT)

BEGIN TAPER (SEE CONTRACT)

WHITE EDGE LINE

NOTES

D (SEE TABLE)

Cl

c:::

c:i
::J

;>.:
[I]

Cl

POSTED
MAIN LINE
SPEED

SINGLE-LANE, PARALLEL TYPE - ON-CONNECTION

35 MPH

565'

40 MPH

670'

2. When weaving section is more than 3/4 of a mile in length, use


lane line.

45 MPH

775'

3. The channelization shown on this plan assumes optimal roadway

50 MPH

885'

55 MPH

990'

60 MPH

1100'

65 MPH

1200'

70 MPH

1250'

geometric design. The dimensions may vary to fit existing


conditions. See Contract.
LEGEND
L = LANE WIDTH
R = RAMP LANE WIDTH

R
R

WIDE LANE LINE

s= --

1. Where shown on the plans or specified in the Special Provisions,


raised pavement markers shall be used to supplement or substitute
for the painted pavement markings shown hereon. See the
Standard Plans for RPM supplement and substitution patterns.

TABLE

LL.

>(.)

LANE LINE

YELLOW EDGE LINE

--

=RAMP=

END OF TAPER
(SEE CONTRACT)

DOTTED LANE LINE

-~

YELLOW EDGE LINE


WHITE EDGE LINE

WHITE EDGE LINE


D (SEE TABLE)
BEGIN TAPER
(SEE CONTRACT)

(WSDOT SIGN FABRICATION MANUALN..Y

DOUBLE-LANE, PARALLEL TYPE - ON-CONNECTION

WIDE DOTTED LANE LINE


(SEE NOTE 2)
LANE LINE

YELLOW EDGE LINE

YELLOW EDGE LINE

Lf~=

LL-

RAMP CHANNELIZATION
PARALLEL ON &
WEAVING SECTION
STANDARD PLAN M-1.80-03

WHITE EDGE LINE

L
SEE CONTRACT
WEAVING SECTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

WHITE EDGE LINE


YELLOW EDGE LINE

SHEET 1 OF 1 SHEET

YELLOW EDGE LINE

WEAVING SECTION

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

YELLOW EDGE LINE

NOTES

1. Install a minimum of 3 sets of diagonals/chevrons in the gore area.


A 50' spacing is standard; however, for gore areas shorter than 150'
use a 25' spacing, and for gore areas greater than 400' a spacing
of 100' may be used.

CHEVRON MARKING {TYP.)


-WHITE CROSSHATCH MARKING
I

_r:-

----

<t

OF GORE AREA

I
I
I
I

2. The acute angle of the diagonals shall always point in the direction
of main line traffic.

----

---

----

SEE NOTE 2

WHITE EDGE LINE

CONTINUE GORE MARKINGS


SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
----ATSAMESPACINGTOEND
----~----~~~~~----~~------~~~~-------r~----~~~---------
OF GORE AREA - SEE NOTE 1

GORE AREA MARKINGS


WITH CHEVERONS

TYPE 2Y RPMS
@ 80' SPACING

TYPE 2W RPMS {TYP.)

CHEVRON MARKING {TYP.)


-WHITE CROSSHATCH MARKING

YELLOW EDGE LINE

----

---,

WHITE EDGE LINE

CONTINUE GORE MARKINGS


SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
----ATSAMESPACINGTOEND
----~----~~~~~----~~------~~~~-------r~-------------------
OF GORE AREA - SEE NOTE 1

GORE AREA SUPPLEMENT


WITH TYPE 2 RAISED
PAVEMENT MARKERS

--L;
I

TYPE 2Y RPM
@ 80' SPACING
WIDE LANE LINE
SUBSTITUTION
PATTERN {TYP.)

YELLOW EDGE LINE

CENTERLINE
OF GORE AREA
CHEVRON MARKING {TYP.)
-SEE CONTRACT

oooo
0

8
8

0 00 0

0 0

0
0
0

TYPE 1W
RPMS {TYP.)

-e--o88
oo
oO

8
oo08ea88

0
- - - -

~-

0 0

0 0 --+0-8 o 8 8 8 8 8 8 8
0

GORE AREA
MARKING LAYOUTS

ooo

0
0

0
0

ooo------

oo

oooo
0

oo
ooo
oO

~-~o

----

ooo
oOo
o
o

8
8

- - -

8
8

888 - r-f- a -

STANDARD PLAN M-2.20-02


SHEET 1 OF 1 SHEET

WHITE EDGE LINE

SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
CONTINUE GORE MARKINGS
----AT SAME SPACING TO END
----~-----:S:-::E::::E=.:C:-.:O:::N=:T:::RA~C=T-----t-----::-S:::::':EE="=:C-=o:::N:::::TRA::-:-:C::T:-----t------::S:-;:E:;:E-::C~O:::-N-;:;T:;:;RA:-;-;::;-CT:;-----OF GORE AREA - SEE NOTE 1

GORE AREA SUBSTITUTION


WITH TYPES 1 & 2 RAISED
PAVEMENT MARKERS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

APPROACH TAPER

SEE CONTRACT FOR LENGTH


OF STORAGE LANE

NOTES

50'

50'
...J

1-

DOUBLE CENTERLINE (YELLOW)


(NARROW PATTERN)

OPTIONAL DOTTED
EXTENSION LINE

WIDE LANE
LINE

...J

CENTERLINE STRIPE
-SEE NOTES

WHITE EDGE LINE

50'

LEFT-TURN CHANNELIZATION
SYMMETRICAL WIDENING ABOUT CENTERLINE

1.

The channelization shown on this plan assumes optimal roadway geometric


design. The dimensions may vary to fit existing conditions. See Contract.

2.

The channelization shown on this plan is for a two-lane highway. The


channelization plan may be used on four-lane undivided highways, with the
appropriate considerations.

3.

Centerline striping on the approach to raised channelization shall be No Pass


in accordance with MUTCD figure 38-15. Centerline striping on the departure
from raised channelization shall be determined by an engineering study.

4.

Centerline striping on the approach to and departure from painted channelization shall be determined by an engineering study.

5.

Centerline striping on four-lane undivided highways shall be a double centerline.

6.

The two Type 2L (SL) Traffic Arrows shown in the left-turn storage lane are
optional, but recommended. Arrows may be added for longer storage lanes
or deleted for shorter storage lanes. See Contract Plans.
LEGEND
L

= 12' Typical Lane Width.

See Contract
for specified lane widths.

~
SEE CONTRACT FOR LENGTH
OF STORAGE LANE

50'

50'

Type 2L (SL) Traffic Arrow

DOUBLE CENTERLINE (YELLOW)

OPTIONAL DOTTED
EXTENSION LINE

POSTED
SPEED

OPTIONAL MARKED DECELERATION TAPER


DOUBLE CENTERLINE (YELLOW)
(NARROW PATTERN)

...J

STOPPING POINT FOR


LEFT TURN LANE
CENTERLINE STRIPE
-SEE NOTES
APPROACH TAPER

WIDE LANE LINE

APPROACH
APPROACH
DIMENSION
TAPER
TAPER

60MPH

360'

60'

720'

55 MPH

330'

55'

660'

50 MPH

300'

50'

600'

45MPH

270'

45'

540'

40MPH

240'

40'

480'

35MPH

210'

35'

420'

30MPH

180'

30'

360'

25MPH

150'

25'

300'

20MPH

120'

20'

240'

LEFT-TURN CHANNELIZATION
ASYMMETRICAL WIDENING LEFT OF CENTERLINE

SEE CONTRACT FOR LENGTH


OF STORAGE LANE

APPROACH TAPER
50'

50'

B
DOUBLE CENTERLINE (YELLOW)
(NARROW PATTERN)

...J

CENTERLINE STRIPE
-SEE NOTES

LEFT-TURN
CHANNELIZATION

STOPPING POINT FOR


LEFT TURN LANE

STANDARD PLAN M-3.10-03


SHEET 1 OF 1 SHEET
WIDE LANE LINE

OPTIONAL DOTTED
EXTENSION LINE

APPROVED FOR PUBLICATION

WHITE EDGE LINE

LEFT-TURN CHANNELIZATION
ASYMMETRICAL WIDENING RIGHT OF CENTERLINE

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

NOTES
APPROACH TAPER
SEE CONTRACT FOR LENGTH
OF STORAGE LANE

50'

1.

The channelization shown on this plan assumes optimal roadway geometric design.
The dimensions may vary to fit existing conditions. See Contract.

2.

The channelization shown on this plan is for a two-lane highway. The channelization
plan may be used on four-lane undivided highways with the appropriate considerations.

3.

Centerline striping on the approach to raised channelization shall be No Pass in


accordance with MUTCD figure 38-15. Centerline striping on the departure from
raised channelization shall be determined by an engineering study.

4.

Centerline striping on the approach to and departure from painted channelization


shall be determined by an engineering study.

5.

Centerline striping on four lane undivided highways shall be a double centerline.

6.

The two Type 2L (SL) Traffic Arrows shown in the left-turn storage lane are optional,
but recommended. Arrows may be added for longer storage lanes or deleted for
shorter storage lanes. See Contract Plans.

H
WHITE EDGE LINE

...J

CENTERLINE STRIPE
-SEE NOTES

DOUBLE CENTERLINE (YELLOW)


{NARROW PATTERN)

LEFT-TURN CHANNELIZATION
REDUCED TAPER LENGTHS- SYMMETRICAL WIDENING

LEGEND

(FOR LIMITED USE IN URBAN AREAS WITH POSTED SPEEDS OF 40 MPH OR LESS)

= 12' Typical Lane Width.

See Contract

for specified lane widths.


~

APPROACH TAPER
SEE CONTRACT FOR LENGTH
OF STORAGE LANE
50'

50'

Type 2L (SL) Traffic Arrow

...J

POSTED
SPEED
DOUBLE CENTERLINE (YELLOW)
{NARROW PATTERN)

CENTERLINE STRIPE
-SEE NOTES

STOPPING POINT FOR


LEFT TURN LANE

OPTIONAL DOTTED
EXTENSION LINE

WIDE LANE LINE

APPROACH
APPROACH
DIMENSION
DIMENSION
TAPER
TAPER
H
K
G
J

40MPH

160'

27'

320'

53'

35MPH

123'

20'

245'

41'

30MPH

90'

15'

180'

30'

25MPH

63'

10'

125'

21'

20MPH

40'

7'

80'

13'

WHITE EDGE LINE

DOUBLE
CENTER
LINE

LEFT-TURN CHANNELIZATION

RADIUS

REDUCED TAPER LENGTHS- ASYMMETRICAL WIDENING RIGHT OF CENTER LINE


(FOR LIMITED USE IN URBAN AREAS WITH POSTED SPEEDS OF 40 MPH OR LESS)

~OF MARKING

RADIUS = RESPECTIVE

H orK

OPTIONAL MARKED DECELERATION TAPER


SEE CONTRACT FOR LENGTH
OF STORAGE LANE
50'

50'

(FOR LIMITED USE IN URBAN AREAS)


OPTIONAL DOTTED EXTENSION LINE

...J

DOUBLE CENTERLINE (YELLOW)


{NARROW PATTERN)

STOPPING POINT FOR


LEFT TURN LANE
WHITE EDGE LINE

WIDE LANE LINE

APPROACH TAPER

CENTERLINE STRIPE
-SEE NOTES

LEFT-TURN
CHANNELIZATION
REDUCED TAPERS
STANDARD PLAN M-3.20-02
SHEET 1 OF 1 SHEET

LEFT-TURN CHANNELIZATION
REDUCED TAPER LENGTHS- ASYMMETRICAL WIDENING LEFT OF CENTER LINE
(FOR LIMITED USE IN URBAN AREAS WITH POSTED SPEEDS OF 40 MPH OR LESS)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

DECELERATION LANE LENGTH

ACCELERATION LANE LENGTH

300' MIN.

1/2 L

OPTIONAL DOTTED
EXTENSION LINE

APPROACH TAPER

WIDE LANE LINE

STOPPING POINT FOR


LEFT-TURN LANE

50'

1-------------1

NO PASS STRIP ON APPROACH


EQUAL TO APPROACH TAPER A

OPTIONAL DOTTED
EXTENSION LINE

WHITE EDGE LINE

....1

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)
INSIDE RADIUS OF
LEFT-TURNING VEHICLE

OPTIONAL
{SEE CONTRACT)

1.

The channelization shown on this plan assumes optimal roadway geometric design. The dimensions
may vary to fit existing conditions. See Contract.

LEFT-TURN CHANNELIZATION

2.

TEE INTERSECTION
WITH ACCELERATION LANE

The channelization shown on this plan is for a two-lane highway. The channelization plan may be used
on four-lane undivided highways with the appropriate considerations.

3.

Centerline striping on the approach to raised channelization shall be No Pass in accordance with
MUTCD figure 38-15. Centerline striping on the departure from raised channelization shall be
determined by an engineering study.

4.

Centerline striping on the approach to and departure from painted channelization shall be determined
by an engineering study.

5.

Centerline striping on four-lane undivided highways shall be a double centerline.

6.

The two Type 2L (SL) Traffic Arrows shown in the left-turn storage lane are optional, but recommended.
Arrows may be added for longer storage lanes or deleted for shorter storage lanes. See Contract Plans.

STOPPING POINT FOR


LEFT-TURN LANE

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)
{OR PAINTED MEDIAN IF LEFT
TURNS ARE PROHIBITED)

NOTES

APPROACH TAPER

100'

LEGEND

OPTIONAL {SEE CONTRACT)


50'

....1

L = 12' Typical Lane Width. See Contract


for specified lane widths.

WHITE EDGE LINE

Type 2L (SL) Traffic Arrow

~ Type 6R (SR) Traffic Arrow


OPTIONAL DOTTED
EXTENSION LINE

WHITE EDGE LINE


CENTERLINE STRIPE
{SEE NOTES)
APPROACH TAPER

INSIDE RADIUS OF
LEFT-TURNING VEHICLE

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

CENTERLINE STRIPE
{SEE NOTES)

VARIES- SEE

CONTRACT PLANS

LEFT-TURN CHANNELIZATION
TEE INTERSECTION
THIS DIMENSION IS BASED ON
A 12' TURN LANE WIDTH

POSTED
SPEED

VARIES

VARIES

{SEE
CONTRACT)

{SEE
CONTRACT)

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

LEFT-TURN CHANNELIZATION
BACK-TO-BACK LEFT-TURN LANES

WIDE LANE
LINE

OPTIONAL DOTTED
EXTENSION LINE
{BOTH DIRECTIONS)

APPROACH
DIMENSION
TAPER

60MPH

360'

60'

55 MPH

330'

55'

50 MPH

300'

50'

45MPH

270'

45'

40MPH

240'

40'

35MPH

210'

35'

LEFT-TURN CHANNELIZATION
TEE INTERSECTION AND
BACK-TO-BACK TURN LANES
STANDARD PLAN M-3.30-03

30MPH

180'

30'

SHEET 1 OF 1 SHEET

25MPH

150'

25'

20MPH

120'

20'

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

SEE CONTRACT FOR LENGTH


OF STORAGE LANE

E+ 50'

25'

500' MAX.

en

,Q

50'

TWO-WAY LEFT-TURN
CENTERLINE

WHITE EDGE
LINE

c:::lc5
Oc:::

Zen
-~en
:!:o
,C:::

1(..)

---....--------1

--------------------------- -----------------------I

en

Cl

c:::<(
oo
...,c:::
<(en

! 16' !

DOUBLE CENTERLINE (YELLOW)


(NARROW PATTERN)

WIDE LANE LINE

:!:en
0

(ivP.)

c:::

NOTES

(..)

LEFT-TURN CHANNELIZATION
IN TWO-WAY LEFT-TURN LANE

:::::100'

TAPER F

TWO-WAY LEFT-TURN
CENTER LINE

WHITE EDGE LINE

1.

The channelization shown on this plan assumes optimal roadway geometric design.
The dimensions may vary to fit existing conditions. See Contract.

2.

The channelization shown on this plan is for a two-lane highway. The channelization
plan may be used on four-lane undivided highways with the appropriate considerations.

3.

Centerline striping on the approach to raised channelization shall be No Pass in


accordance with MUTCD figure 38-15. Centerline striping on the departure from
raised channelization shall be determined by an engineering study.

4.

Centerline srtiping on the approach to and departure from painted channelization


shall be determined by an engineering study.

5.

Centerline striping on four-lane undivided highways shall be a double centerline.

6.

The two Type 2L (SL) Traffic Arrows shown in the left-turn storage lane are optional,
but recommended. Arrows may be added for longer storage lanes or deleted for shorter
storage lanes. See Contract Plans.
LEGEND
POSTED
SPEED

I' 16' I'

CENTERLINE STRIPE
(SEE NOTES)

DOUBLE CENTERLINE (YELLOW)


(NARROW PATTERN)

r----1

DIMENSION
E0

APPROACH
TAPER
F

HIGH SPEED

TWO-WAY LEFT-TURN LANE TRANSITION

60MPH

180'

360'

55 MPH

180'

330'

50 MPH

180'

300'

45MPH

180'

270'

L = 12' Typical Lane Width. See Contract for


specified lane widths.
~

Type 2L (SL) Traffic Arrow

LOW SPEED

SEE CONTRACT FOR LENGTH


OF STORAGE LANE
....1

50'

OPTIONAL DOTTED
EXTENSION LINE

120'

240'

35MPH

120'

210'

30MPH

120'

180'

25MPH

120'

150'

20MPH

120'

120'

Can be reduced to a minimum of


50' to increase storage capacity.

, . DIRECTION OF TRAFFIC
YELLOW EDGE LINE
YELLOW CROSSHATCH
MARKING

20' MIN.

WIDE LANE LINE


DOUBLE CENTERLINE (YELLOW)
(NARROW PATTERN)

40MPH

PAINTED OR PLASTIC
MEDIAN - SEE DETAIL

40' MAX.

YELLOW EDGE LINE

YELLOW EDGE LINE

TWO-WAY LEFT-TURN
AND MEDIAN
CHANNELIZATION
STANDARD PLAN M-3.40-03
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

DIRECTION OF TRAFFIC

Pasco Bakotich Ill

LEFT-TURN CHANNELIZATION
IN PAINTED MEDIAN

PAINTED OR PLASTIC MEDIAN


COMPOSED OF LONGITUDINAL MARKINGS

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

NOTES

40' IF POSTED SPEED IS 40 MPH OR LESS


100' IF POSTED SPEED IS MORE THAN 40 MPH

VARIES

APPROACH TAPER

60' MIN.

1.

The channelization shown on this plan assumes optimal


roadway geometric design. The dimensions may vary to
fit existing conditions. See Contract.

2.

The channelization shown on this plan is for a two lane


highway. The channelization plan may be used on four
lane undivided highways with the appropriate consideratiions.

3.

Centerline striping on the approach to raised channelization


shall be No Pass in accordance with MUTCD Figure 38-15.
Centerline striping on the departure from raised channelization shall be determined by an engineering study.

4.

Centerline striping on the approach to and departure from


painted channelization shall be determined by an engineering
study.

5.

Centerline striping on four lane undivided highways shall be


double centerline.

6.

All turn traffic arrows are optional, but recommended. Arrows


may be added for longer storage lanes or deleted for shorter
storage lanes. See Contract Plans.

50'

WHITE DOTTED EXTENSION LINE


(RECOMMENDED)

DOUBLE CENTERLINE (YELLOW)


(NARROW PATTERN)

STOPPING POINT
FOR LEFT
TURN LANE

WHITE EDGE LINE

VARIES

CENTERLINE STRIPE
-SEE NOTES

LANE LINE

WIDE LANE LINE


WHITE DOTTED EXTENSION LINE

DOUBLE-LEFT TURN CHANNELIZATION


WITH RIGHT TURN POCKET

LEGEND

50'

L = 12' Typical Lane Width. See Contract for specified


lane widths.
~ Type 2L (SL) Traffic Arrow

APPROACH TAPER C

VARIES

WIDE LANE
LINE

Type 2R (SR) Traffic Arrow

DOUBLE CENTERLINE (YELLOW)


(NARROW PATTERN)

LANE LINE

STOPPING POINT

T~~~ t!~~ ~~===~="====~=========~

- - - - - - - - - - - - - - - - - - - -

-----;-;---~t-~::j~~~-~===.j~~.=:.:~==~~~~~~==z=~~:::f~t-r=------,-~-----,
WHITE DOTTED EXTENSION LINE
(RECOMMENDED)

LANE LINE

POSTED
SPEED

WHITE EDGE
LINE
CENTERLINE STRIPE
-SEE NOTES

WHITE DOTTED EXTENSION LINE

DOUBLE-LEFT TURN CHANNELIZATION


CENTERLINE STRIPE
-SEE NOTES
DOUBLE CENTERLINE (YELLOW)
(NARROW PATTERN)

VARIES - EQUAL SPACING

VARIES - EQUAL SPACING

APPROACH
TAPER

60MPH

720'

420'

55 MPH

660'

385'

50 MPH

600'

350'

45MPH

540'

315'

40MPH

480'

280'

35MPH

420'

245'

30MPH

360'

210'

25MPH

300'

175'

20MPH

240'

140'

50'
DIRECTION OF TRAFFIC
WHITE CROSSHATCH MARKINGS

DOUBLE LEFT-TURN
CHANNELIZATION
STANDARD PLAN M-3.50-02
OPTIONAL DOTTED
EXTENSION LINE
APPROACH TAPER

40' MAX.
C

SINGLE LEFT-TURN CHANNELIZATION


FACING OPPOSING DOUBLE LEFT TURNS

SHEET 1 OF 1 SHEET

20' MIN.

WHITE EDGE LINE


PAINTED OR PLASTIC TRAFFIC
DIVIDER - SEE DETAIL

WIDE LANE LINE

DIRECTION OF TRAFFIC

_..

PAINTED OR PLASTIC TRAFFIC DIVIDER


COMPOSED OF LONGITUDINAL MARKINGS

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

NOTES
50' MIN. {SEE CONTRACT)
50'

300' MIN.
VARIES

1.

The channelization shown on this plan assumes optimal roadway geometric design.
The dimensions may vary to fit existing conditions. See Contract.

2.

The channelization shown on this plan is for a two-lane highway. The channelization
plan may be used on four-lane undivided highways with the appropriate considerations.

3.

Centerline striping on the approach to raised channelization shall be No Pass in


accordance with MUTCD figure 38-15. Centerline striping on the departure from
raised channelization shall be determined by an engineering study.

4.

Centerline striping on the approach to and departure from painted channelization


shall be determined by an engineering study.

5.

Centerline striping on four-lane undivided highways shall be a double center line.

6.

All Traffic Arrows not required are optional, but recommended. Arrows may be added
for longer storage lanes, or deleted for shorter storage lanes. See Contract Plans.

WHITE EDGE LINE

WIDE LANE LINE


OPTIONAL DOTTED
EXTENSION LINE

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

CENTERLINE STRIPE
{SEE NOTE)

LEGEND

RIGHT-TURN CHANNELIZATION

= 12' Typical Lane Width. See Contract for specified lane widths.
* = Denotes required traffic arrow. Accompanying ONLY word
L

message optional. See Standard Plan M-80.10

for spacing.

~ Type 2R (SR) Traffic Arrow


300'

300'
WIDE DOTTED
LANE LINE

75' MIN.

VARIES

{SEE CONTRACT)

LANE LINE

CENTERLINE STRIPE
{SEE NOTE)

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

WIDE LANE LINE

Type 3L (SL) Traffic Arrow

WHITE EDGE LINE

RIGHT-TURN CHANNELIZATION
WITH DROP LANE

WHITE DOTTED EXTENSION LINE


DOTTED
EXTENSION
LINE

200' MIN. {SEE CONTRACT)


VARIES

75' MIN.
{SEE CONTRACT)

50' MIN. {SEE CONTRACT)

WIDE DOTTED
LANE LINE

LANE LINE

RIGHT-TURN
CHANNELIZATION
STANDARD PLAN M-5.10-02
LANE LINE

WIDE LANE LINE

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

CENTERLINE STRIPE
{SEE NOTE)

SHEET 1 OF 1 SHEET

WHITE EDGE LINE

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

DOUBLE RIGHT-TURN CHANNELIZATION

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

NOTE

HOV LANE

When Specified in the Contract Plans, the HOV Symbol Marking shall
be installed with an offset of 1 foot max. from the lane centerline.
2'- 6"

1'- 3"

w
b

'

':i
~-

::!!: ::!!:

1- 1-

w w
w ~
LL 0
ceo

II

~(.!)

II

'

(.!)(3

z <(
~CJ)
-D..

D.. 1-

CJ)W

s"

(NP.)

0::

S:!ii
~~
J:(3

LL

....1

~ 1-

'

----~

MARKING AREA
11.40 SQ.FT.

HOV LANE SYMBOL

HIGH OCCUPANCY VEHICLE


(HOY) LANE SYMBOL
LAYOUT
STANDARD PLAN M-7.50-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

LAYOUT

Ken L. Smith
-~----~ST~~~E~DE~SIG~N~EN~G~INE~ER~-----

f/'1

01-30-07
DATE

Washington State Department of Transportation

3'- 4"

1'- 0"
I

1/

1\

=B v
\

1/

'

1\

'I- 1 \

1\

IJ

'

'

I 1\

I
b

'

1/

l-

v
t>

u:::

11..

BICYCLE
LANE

ct

'"

TOTAL MARKING AREA


10.27 SQ.FT.

'

rt

1/

tF

I-

'

1\

II

I~l-

II

'

1/
1\

7T

II

1-

II

-tt-n

*
n

II

1\

I'll

r~

17

1-

1-r1-r-

rr-

1/

'

l
II

WIDE LANE LINE

II

1\

'"

1\

'

tIt-

- l-1- If_

I-

......

I-

~~

1/
J
I[_

I-

......

EDGE OF
BIKE LANE
GRID IS 1" SQUARE

MARKING AREA
6.02 SQ.FT.

MARKING AREA
4.25 SQ.FT.

3"

6"

BIKE RIDER SYMBOL


DETAIL
BIKE LANE ARROW
DETAIL

KEYNOTES

BICYCLE LANE SYMBOL


LAYOUT

CD

Bid Item "Bicycle Lane Symbol"


includes Bike Lane Arrow and
Bike Rider Symbol.

STANDARD PLAN M-9.50-01


SHEET 1 OF 1 SHEET

GENERAL NOTE
2' x 6' White Bike Lane Arrow

@ Bike Rider Symbol

BICYCLE LANE SYMBOL


LAYOUT

See contract for location and material requirements.

APPROVED FOR PUBLICATION

Ken L. Smith

------~~~~~-----.....
STATE DESIGN ENGINEER

01-30-07
DATE

fJ'1 Washington State Department of Transportation

20'- 0" MIN.

9'- 0"

3'- 0"

9'- 0"

3'- 0"

9'- 0"
3'- 0"

9'- 0"

10'- 0" MIN.

5'- 0"

10'- 0" OR MIN.


SIGHT DISTANCE
(SEE NOTE 1)

5'- 0"

5'- 0" I 5'- 0"

9'- 0"

10'- 0" MIN.

3'- 0"

r----------~

.f:===r-==::==:::::::~SiE~~I=:::::::==::==:::::===::=~~~ :ut~~-==-:::::::-=-=--=::::=-:::3----I
I
I
I

4" WIDE SOLID YELLOW


PAINTED LINE

BOLLARD

- - - - - - - - - \ _ STRUCTURE

PLAN
4" WIDE BROKEN YELLOW
PAINTED LINE

3'- 0"

PAVED PATH

PLAN
CENTERLINE MARKING
9'- 0"

::~~::SING

MARKING AROUND MULTIPLE BOLLARDS

5'- 0"

5'- 0"

9'- 0"

10'- 0" OR MIN. SIGHT


DISTANCE (SEE NOTE 1)

PAVED PATH

NOTE:
1.

In cases where the ballard location is not visible to an approaching bicyclist, use the minimum sight distance for the
Solid Yellow Painted Line (taper portion), to extend the
Solid Yellow Painted Line as needed to provide advanced
warning of the upcoming obstruction.

2.

In cases where there is a crossing, bridge or other structure


on the path that does not support or accomodate a vehicle.
(See Contract).

3.

Provide Breakaway Bollards within the Roadway Design


Clear Zone.

3'- 0"

J:<:""'

I-

-~ -

(SEE NOTE 2)

SHOWN AT REDUCED DRAWING SCALE

10'- 0"

--

<( ......

0.. z
LlJ <(
I

-------- - - -

--

en
=>I, en

- -t=====:=l----(

oen
LlJ

0::: 1-

<(0

J:

en~

4" WIDE SOLID YELLOW


PAINTED LINE

BOLLARD

PLAN
MARKING AROUND BOLLARD

PAVED PATH

50'- 0"
VARIES

4'- 0"

EDGE OF
SHOULDER

5'- 0"

4'- 0"

- 011

9'- 0"

- 011

DETAIL

J:<:""'

t-O

<( ......

c..z
en I
=>I, en
oen

UJ<(

UJ~

c:::l-

<(0

PAINTED TRAFFIC LEITERS

Iz

en~

CROSSWALK
LINE

SHARED - USE PATH


MARKINGS

PAVED PATH

STANDARD PLAN M-9.60-00

DETECTABLE WARNING
SURFACE

4" WIDE SOLID YELLOW


PAINTED LINE

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

2'- 0" MIN.

PLAN
MARKING AT INTERSECTION WITH ROADWAY

Pasco Bakotich Ill

fll
......

STATE DESIGN ENGINEER

02-10-09
DATE

Washington State Department o Transportation

GENERAL NOTE
See contract for location and material requirements.

1'- 2"
b

'

II
1-\

~
b
N

STOP LINE

STOP LINE

'

....1

Ill

0~
w
w

MPH
25

+-

....1

D*

Ill
(0

50 Ft.

30

100Ft.

35

150Ft.

40

225Ft.

45

300Ft.

50

375Ft.

55

450Ft.

60

550Ft.

65

650Ft.

w
w

'

F-

'

SYMBOL DETAIL

*DIMENSIONS SHOWN
ARE APPROXIMATE.
SEE CONTRACT.

GRID IS 1" SQUARE

"R" DETAIL
SYMBOL DETAIL
EDGE LINE

LANE LINE OR
ROADWAY
CENTERLINE

EDGE LINE

LANE LINE OR
ROADWAY
CENTERLINE

KEYNOTES
LAYOUT

LAYOUT

G) Bid Item "Railroad Crossing Symbol" includes


G)

TOTAL MARKING AREA


(PER 12' WIDE LANE)
= 109.75 SQ.FT.

STANDARD SYMBOL

"X" symbol, letters, and two 24" white transverse lines.

24" white transverse line


W1 0-1 Advance Warning Sign (not included
in RR Crossing Symbol Bid Item)
Place Stop Line 15' from the nearest rail or
approximately 8 feet from RR gate, if present.

G)

TOTAL MARKING AREA


(PER 12' WIDE LANE)
111.59 SQ.FT.

RAILROAD CROSSING
LAYOUT
STANDARD PLAN M-11.10-01

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

ALTERNATIVE SYMBOL

....

Ken L. Smith
STATE DESIGN ENGINEER

01-30-07
DATE

fJ'I Washington State Department of Transportation

ROADWAY

....1
....1

c
c

SHOULDER AREA

::::i

1' WIDE FOR 4' SHOULDERS

2' WIDE FOR SHOULDERS OVER 4' WIDE

~
c

INSTALL CROSSWALK LINES IN


SHOULDER AREAS ONLY WHEN
ADJACENT TO A SIDEWALK OR
A SEPARATE WALKWAY (TYP.)

CROSSWALK LINE
SIDEWALK

SIDEWALK

EDGE OF CONCRETE
GUTTER

EDGE OF CONCRETE
GUTIER

~
5'MAX.

EDGE OF PAVEMENT, OR FACE OF


CURB (WITHOUT GUTIER), OR EDGE
OF GUTIER PAN (WHEN THERE IS
CURB & GUTIER) (TYP.)

1lr 4~i

0:::

LL

LANE

(TYP.)

7-

-..... :Z
::iE

STOP LINE

EDGE OF TRAVELED WAY

EDGE OF TRAVELED WAY


LANE

LANE
SHOULDER AREA

SHOULDER

SHOULDER

DETAIL

NOTES

1. See the Contract Plans for locations of crosswalk centerlines.


2. To the maximum extent possible, curb ramp centerline should
be perpendicular to the crosswalk centerline.
3. To the maximum extent possible, crosswalks should be
perpendicular to the centerline of the traveled way.
SIDEWALK

SIDEWALK

EDGE OF CONCRETE
GUTTER

EDGE OF CONCRETE
GUTIER

SHOULDER

SHOULDER

CROSSWALK LAYOUT
STANDARD PLAN M-15.1 0-01
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

.....

Ken L. Smith

------~S~~~TE~D~ES~IG~N~EN~G~IN~EE~R------

02-06-07
DATE

fJ'I Washington State Department of Transportation


TYPICAL APPLICATIONS

CEMENT
CONCRETE
SIDEWALK

SIDEWALK RAMP & ACCESS ZONE

t_

2'- 0"
{TYP.)
FACE
OF
CURB

4" WIDE, YELLOW


PAINT LINES

FACE OF CURB

4" WIDE, YELLOW


PAINT LINES

4" WIDE, WHITE


PAINT LINE {TYP.)

4" WIDE, WHITE


PAINT LINE {TYP.)

....1
....1

0
0

1'- 4"

::::i

SEE DETAIL A

8' - 0" MIN.

a:
w

LL.

8'- 0" MIN.

5'

t;.

DETAIL A
8'- 0" MIN.

8'- 0" MIN.

8'- 0" MIN.

PLAN
ONE ACCESSIBLE STALL

PLAN
TWO ACCESSIBLE STALLS

90" PARKING STALL ARRANGEMENT

90" PARKING STALL ARRANGEMENT

4'- 0" MIN.

SIDEWALK RAMP

t_

SIDEWALK RAMP

8' - 0" MIN.

PLAN
ALTERNATIVE PARKING STALL MARKINGS
USE ONLY WHEN SPECIFIED IN THE CONTRACT

NOTES
4'- 0" MIN.

CEMENT
CONCRETE
SIDEWALK

5' - 0"
or 8'- 0"

1. Three, four and five accessible stall arrangements may be either 60" (angled) or 90" (perpendicular) parking arrangements. See Contract.

t_
2. An Access Parking Space Symbol is required for each accessible parking stall. A blue
background and white border are required when the symbol is installed on a cement concrete surface.
3. All accessible stalls shall have wheel stops. Place wheel stops in other stalls when specified in the contract. Wheel stops shall be approximately 6" high and a minimum of 6' long.
4. Refer to the Standard Plans for sidewalk ramp, detectable warning pattern, and curb details.

4" \MOE, WHITE\

LEGEND

PAINT LINE {TYP.)

---t-1-------x- - - -~1

I --

{SEE TABLE)

PLAN

~~ i. ~'-~~

cg , ~

5'- 9"

ONE ACCESSIBLE STALL

STALL
WIDTH

8'- 0"

9'- 3"

9'- 0"

10'- 5"

10'- 0"

11'- 7"

11'- 0"

12'- 8"

X
{SEE TABLE)

b
~

Access Parking Space Symbol

&\\S\\S\S\'1

PLAN
TWO ACCESSIBLE STALLS

12'- 0" 13'- 10"

SO" PARKING STALL ARRANGEMENT

Reserved Parking Sign and post


with (R7-801A) Plaque, if indicated
(See Sign Fabrication Manual)

,_. (R _
7 801

lliTITiili]

Manufactured wheel stop


Detectable Warning Pattern

SO" PARKING STALL ARRANGEMENT


SIDEWALK RAMP

PARKING SPACE LAYOUTS


STANDARD PLAN M-17.10-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

\o!-~

"Y

\o!-~

FOUR ACCESSIBLE STALLS

Pasco Bakotich Ill

......
fll

STATE DESIGN ENGINEER

07-03-08
DATE

Washington State Department of Transportation

Cl

0::

LL.

~
<(

en
:J

10'

~J

30'

SEE CONTRACT FOR LENGTH

,----------

,-----J;'=-------

T----:-

:;..:

Ill

CENTERLINE & LANE LINE

YELLOW- CENTERLINE,

I"

WHITE - LANE LINE

Cl

SEE CONTRACT FOR LENGTH

10'

~~~_e----1l

30'

10'

,----------

"

~~-1

~T~T

4"0R12"-

~r:-----------------------~~-~ ~~E~~3

1
DOUBLE CENTERLINE & DOUBLE LANE LINE

'""{

YELLO= DBL CENTERLINE,


WHITE - DBL. LANE LINE

SEE CONTRACT FOR LENGTH

YELLOW

NO-PASS LINE & TWO-WAY LEFT-TURN CENTERLINE

30'

WIDE LANE LINE


SEE CONTRACT FOR LENGTH

REVERSIBLE LANE LINE

10'

DOUBLE WIDE LANE LINE

30'

"'\

L _ _ _ __ _ _ _ j

WIDE BROKEN LANE LINE

SEE CONTRACT FOR LENGTH

\I\IHITE

BARRIER CENTERLINE
3'

l l

9'

3'

ll

~I

9'

3'

9'

ll

3'

ll

l'' l

9'

~-ITE

WIDE DOTTED LANE LINE

6'

6'

.j"__J 'I"

9'

DOTTED EXTENSION LINE

9'

\__ITE

DOTTED LANE LINE

1. Dotted Extension Line shall be the same color


as the line it is extending.
2.

Edge Line shall be white on the right edge of


traveled way, and yellow on the left edge of
traveled way (on one-way roadways). Solid
Lane Line shall be white.

3. The distance between the lines of the Double


Centerline shall be 12" everywhere, except
4" for left-turn channelization and narrow roadways with lane widths of 10 feet or less. Local
Agencies (on non-state routes) may specify a
4" distance for all locations.

3'

\ _ _ YELLOW OR WHIT: r - -SEE NOTE 1

NOTES

The distance between the lines of the Double


Lane Line shall be 4".

LONGITUDINAL MARKING
PATTERNS
STANDARD PLAN M-20.10-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill


06-03-11
-. .- - STATE
==
------DATE
...
DESIGN ENGINEER

fll

Washington State Department of Transportation

GENERAL NOTE

See Standard Plan M-20.1 0 for pattern and color requirements.

10'- 0"

23"

23"

23"

23"

1}~~- ~1-

w[l
~

23"

PERSPECTIVE VIEW

~~}~~-

FOR:

(BROKEN LINE)

CENTER LINE & LANE LINE - w =4"


NO-PASS LINE & TWO-WAY LEFT-TURN CENTER LINE- W
REVERSIBLE LANE LINE - W =4"
WIDE BROKEN LANE LINE - W =8"

PROFILED PLASTIC

=4"

FOR:

10"

1 100 TO 300 MILS

3'- 0"

10"

1 4" 1

~~}~~-

(SOLID LINE)

:= 1" (TYP.)

D
SIDE VIEW

2'- 0"

23"

~~}~~-

TOP VIEW

SIDE VIEW

PROFILED PLASTIC

23"

TOP VIEW

NO-PASS LINE - w =4"


TWO-WAY LEFT-TURN CENTER LINE - W 4"
DOUBLE CENTER LINE & DOUBLE LANE LINE - W
EDGE LINE & SOLID LANE LINE - W =4"
WIDE LANE LINE & WIDE LINE - W =8"
DOUBLE WIDE LANE LINE - W = 8"
BARRIER CENTER LINE - W = 20"

=4"

20"

4"

//
~
TOP VIEW

90 MILS MIN.

-..c:==---T-O_P_V-IE_,Eff
DETAIL

0
SIDE VIEW

SIDE VIEW

EMBOSSED PLASTIC

FOR:

(SOLID OR BROKEN LINE)

CENTER LINE & LANE LINE


NO-PASS LINE & TWO-WAY LEFT-TURN CENTER LINE
REVERSIBLE LANE LINE
DOUBLE CENTER LINE & DOUBLE LANE LINE
EDGE LINE & SOLID LANE LINE

SIDE VIEW

DOTTED EXTENSION LINE - W =4"


WIDE DOTTED LANE LINE - W =8"

DROP LANE LINE - W

DETAIL0

7 1/2"

=8"
~

500 MILS MIN.

c;;~M
0

PROFILED PLASTIC
(BROKEN LINE)

SECTION

23"
I

1"

1"

O"T02"

O"T02"

4"

1"

11

:::::

:::::

1"

O"T02"

4"

[I 1:1 1:1

II

II
TOP VIEW

NOT TO SCALE

160 MILS MIN.

500 MILS MIN.

-1

r/4"

160 MILS MIN.

500 MILS MIN.

-1

r/4"

~~~~c5T~03WOM=I~~~/-~_~~----~\~~~1~~~~=100UTO=~~MIL~S~ m~~~~~~!--~~
5

(SOLID OR BROKEN LINE)

FOR:

CENTER LINE & LANE LINE


NO-PASS LINE
TWO-WAY LEFT-TURN CENTER LINE

STANDARD PLAN M-20.20-01


SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

SIDE VIEW

PROFILED EMBOSSED PLASTIC

PROFILED AND EMBOSSED


PLASTIC LINES

REVERSIBLE LANE LINE


DOUBLE CENTER LINE & DOUBLE LANE LINE
EDGE LINE & SOLID LANE LINE

....

Ken L. Smith

----~ST~~~E~DE=SIG~N~EN~G~INE~ER~----

fJ'I Washington

01-30-07
DATE

State Department of Transportation

80'

15'

15'

10'

SEE NOTE 1

30'

80'

10'

15'

NOTES

SEE NOTE 1
~ WHITE EDGE LINE

TYPE 2YY RPM (TYP.)

I
I

\_

II

CENTER LINE

\_

-------

NO PASS LINE

\_

\=
\

DOUBLE CENTER LINE

=
I

\_

NO PASS LINE

TWO LANE TWO-WAY TRAFFIC

15'

10'

30'

2. Type 2Y RPM's, when specified, shall be placed outside


the left Edge Line at 80' intervals. See "LEFT EDGE OF
LANE PLACEMENT DETAIL".
3.

Recessed pavement markers, when specified, shall be


installed at the locations shown for Type 2W RPM's on
multilane one-way roadways, and Type 2YY RPM's on
two lane two-way roadways.

4. The Type 2W RPM's placed on multilane one-way roadways and all RPM's set in recesses shall have an
abrasion resistant coating.

80' - SEE NOTE 1

15'

1. Raised Pavement Markers Types 2YY and 2W shall be


spaced at 80' intervals on tangents and on horizontal
curves with a radius of 5000' or more, and at 40' intervals on horizontal curves having radii of less than 5000'.
Center the RPM's in the gaps between the pavement
marking lines.

10'

WHITE EDGE LINE

15'

LANE LINE

TYPE 2 RPM RAISED FACE COLORS


TYPE 2YY

j.

TYPE2WRPM
(SEE NOTE 1 & 4)

.j

80'

TYPE 2Y RPM
(SEE NOTE 2)

'I'

FLAT

YELLOW - ONE SIDE ONLY

TRAFFIC LANE

I
TAPER LENGTH

1'--------~---_-MAR____.___T1i--------'--E----=----=------_

TYPE2YRPMA

LEFT EDGE OF LANE PLACEMENT DETAIL

WHITE - ONE SIDE ONLY

TYPE2Y

LEFT EDGE LINE

RECESS LENGTH

TAPER LENGTH

TYPE2W
YELLOW
EDGE LINE

MULTILANE ONE-WAY TRAFFIC

YELLOW AND YELLOW

________,[}

-0

SEE NOTE 2

PLAN VIEW
TYPE 2YY RPM (TWO-WAY)
TYPE 2W RPM (ONE-WAY)
(SEE NOTE 4)

TOP OF PAVEMENT MARKER

------------------------~~~~~~~v~~~~~]__ _
40

40

1/8" MIN.
1/4" MAX.

SECTION

ADHESIVE

LONGITUDINAL MARKING
SUPPLEMENT WITH RAISED
PAVEMENT MARKERS
STANDARD PLAN M-20.30-02
SHEET 1 OF 1 SHEET

RECESSED PAVEMENT MARKER DETAILS


FOR USE WHERE SPECIFIED IN CONTRACT

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

10-14-09
DATE

Washington State Department of Transportation

WIDE LANE LINE


-SEE DETAIL!()

OPTIONAL
-SEE NOTE 3

NOTES

DOUBLE CENTERLINE (YELLOW)


- SEE DETAIL

1. Raised pavement markers shall be installed only when


specified in the Contract Plans.
2. See the Standard Plans for marker designation.
3. The portion labeled "OPTIONAL" is only used when the
Optional Marked Deceleration Taper (see Standard Plans
M-3.1 0 and M-3.20) is specified in the Contract Plans.
~

DOUBLE CENTERLINE (YELLOW)


- SEE DETAIL

Type 2L (SL) Traffic Arrow

SEE DETAIL { )

LEFT-TURN LANE
(SEE NOTE 3)

I -

WIDE LANE LINE

TWO-WAY LEFT-TURN CENTERLINE


/

SEE DETAIL!()

~
0

c()

/I

/=
\=

-SEE DETAIL

~0

//=

"~

-<J?'

[=

\ _ DOUBLE CENTERLINE (YELLOW)


-SEE DETAIL

LEFT-TURN LANE

TWO-WAY LEFT-TURN LANE

TWO-WAY LEFT-TURN LANE


30'

SEE DETAIL

I
~

D
D

LONGITUDINAL MARKING
SUPPLEMENT WITH RPMs
-TURN LANES
STANDARD PLAN M-20.40-02
SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

END TWO-WAY LEFT-TURN LANE

STATE DESIGN ENGINEER

06-03-11
DATE

fll Washington State Department of Transportation

40' - 0" SPACING


WIDE LANE LINE

0::

::JW

f-;"Z

t;::5
w

DOUBLE CENTERLINE {YELLOW)

....1

INSIDE EDGE
OF LANE

TYPE 2YY
RPM {TYP.)

DETAIL

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

DETAIL

ALTERNATIVE LINE DETAIL

15'- 0"

.~~;s~

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

TYPE 2YY
RPM {TYP.)

10'- 0"

30'- 0"

10'- 0"

l l

15'- 0"

~------~----~

TWO-WAY LEFT-TURN
CENTERLINE

[IIJ

[IIJ

DETAIL
40' RPM SPACING

[IIJ

40' RPM SPACING


4" {TYP.)

4" {TYP.)

[TIJ

[TIJ
DOUBLE CENTERLINE {YELLOW)
{NARROW PATTERN)

!Tilt !Til

[IIJ

[IIJ

DOUBLE CENTERLINE {YELLOW)


{NARROW PATTERN)

III] _l_ III]

DETAIL

LONGITUDINAL MARKING
SUPPLEMENT WITH RPMs
-TURN LANES
STANDARD PLAN M-20.40-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

4" {TYP.)

TYPE 2YY RPMs


::::: 10' O.C. {TYP.)

DETAIL

Pasco Bakotich Ill


06-03-11
---------------------STATE DESIGN ENGINEER
DATE

.....

fll Washington State Department of Transportation

NOTE

I:

Cl

0::

LL.

12'

.4 <TYP.>.
1

en

~[II]

:;..:

Ill

[II]

I.

<(

:J

Cl

1. The NO PASS LINE (when required) is


applied parallel to the CENTERLINE, 4"
away, with the Type 2YY RPM's aligned
(similar to TWO-WAY LEFT-TURN LINE).

.I.

0
0

0
0

[II]

0
0

[II]

.I

20'

TYPE 1Y RPM (TYP.)

0
0

[II]

TWO-WAY LEFT-TURN LANE

0
0

[II]

THROUGH TRAFFIC LANE

TWO-WAY LEFT-TURN CENTERLINE

l . (TYP.J.I

40'
12'

.I.

~~1YRPM~P)

I.
CENTERLINE

[I]

\~2YYRP~~)

28'

.I.

1:

[I]

0
0

[II]
REVERSIBLE LANE LINE
40'

1:

.I.

I" (TYP.J.I
0
0

TYPE 1Y RPM (TYP.)

DIRECTION OF TRAFFIC

0
0

0
0

0=:}[

0
0

NO PASS LINE

TYPE 1Y RPM (TYP.)

_l

[II]

SEE NOTE 1

l (TYP ~~
0
0

0
0

:1-

TYPE 2YY RPM (TYP.)- DBL. CENTERLINE,

rve~w ~M

ao~~E uNL

0
' - TYPE 1Y

IITJ

~~

~M (TYP.)~DBL CENTERLINE,

TYPE 1W RPM (TYP.) - DBL. LANE LINE

DOUBLE CENTERLINE & DOUBLE LANE LINE

8 8}

DIREC~O~~AAFFIC

TYPE 2W RPM (TYP.)

TYPE 1W RPM (TYP.)

WIDE DOTTED LANE LINE

40'

28'

[I]

DIRECTION OF TRAFFIC

I" 4' (TYP.).I

TYPE 1W RPM (TYP.)

[II]

DIRECTION OF TRAFFIC

oq

TYPE 1W RPM (TYP.)

LANE LINE

8 8

[II]

I" 4' (TYP.).I

TYPE 1W RPM (TYP.)

WIDE BROKEN LANE LINE

20'

4'

28'

12'

~:.~RPM:)

\TY~2YYRP~~)

[II]

40'
12'

20'

DOTTED LANE LINE

4' (TYP.).

6'

LONGITUDINAL MARKING
SUBSTITUTION W/RAISED
PAVEMENT MARKERS
STANDARD PLAN M-20.50-02

8'

8 8

L~~NLINE

DIRECTION OF TRAFFIC

WIDE LANE LINE

[I]

DOTTED EXTENSION LINE

SHEET 1 OF 1 SHEET

LINE~

MATCH TYPE IN
BEING EXTENDED

BEING EXTENDED

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

NOTE
SYMBOL
& LANE

SYMBOL
& LANE

Use the dimensions shown on this plan for each


type Traffic Arrow being placed on roadways with
a posted speed limit of 45 mph or higher.

ct

ct
2'- 0"

1'- 10"

1'- 8"

11
II

L
I

_l

"''"
"'"

Co

'

Co

lo

....'
b

'

'

lo

..........

...."''"

v-

ELLIPSE "A"

"'< I

~'

1\

\
r - ELLIPSE "B"

1\

I/

v
\

"'"

CENTER POINT ~
OF ELLIPSES

'

\
\
\

1\
1\
\

en

=
c(
Co =
' w
in en

'

r\

0..

en

::::i
...J
w

lo ~
' w

C\1

en
0..
::::i
...J
w

r-., l\
I

MARKING AREA
17.44 SQ.FT.

MARKING AREA
17.93 SQ.FT.

"''"

MARKING AREA
17.93 SQ.FT.

(<)

I
GRID IS 4" SQUARE

I l

6"

1'- 0"

1'- 0"

1'- 8"
1
/

TYPE 1 TRAFFIC ARROW

2'- 4"
ELLIPSE A "AXI
II

1'- 4"- ELLIPSE "B" AXIS __/

TYPE 2L (LEFT)
TRAFFIC ARROW

TYPE 2R (RIGHT)
TRAFFIC ARROW
MIRROR IMAGE OF
TYPE 2L TRAFFIC ARROW

SYMBOL MARKINGS
TRAFFIC ARROWS FOR
HIGH SPEED ROADWAYS
STANDARD PLAN M-24.20-01
SHEET 1 OF 3 SHEETS
APPROVED FOR PUBLICATION

Harold J. Peterfeso
STATE DESIGN ENGINEER

05-31-06
DATE

....
f

fJ'I
Washington State Department o Transportation

SYMBOL & LANE

2'- 0"

~
2'- 6"

1'- 0"

1'- 6"

j_s- SYMMETRICAL ABOUT

1'- 2"

CENTERLINE

1'- 8"

3'- 2"

-I
I

lA

~ ~ SYMBOL

I
J

tt~

f-

f-

2'- 0"

t
It

I
b

'

'

.....

I
\

&>

"'~

>

r'<

......

\
\

II

&>~
_. w

N(f)

D..

::::i
....1

rz"'
'/

"-

CENTER POINT
OF ELLIPSES

....
'

GRID IS 4" SQUARE


I

' w

in
(/)

&>~

(/)

D..

::::i

8"

1'- 0"

' w

I \
1

N(f)

2' - 0" - ELLIPSE "A" AXIS

D..

::::i

~ k\

....1

1' - 0"

- ELLIPSE

II

II

1'- 8"

B AXIS

TYPE 4 TRAFFIC ARROW

....
'
(t)

'

(t)

MARKING AREA
33.82 SQ.FT.

SYMBOL MARKINGS
TRAFFIC ARROWS FOR
HIGH SPEED ROADWAYS
STANDARD PLAN M-24.20-01

SHEET 2 OF 3 SHEETS

1'- 4"- ELLIPSE "B" AXIS


1'- 8"
I

MARKING AREA
28.40 SQ.FT.

<X:
io =

MARKING AREA
33.82 SQ.FT.

....1

....1

GRID IS 4" SQUARE

::::i

(t)

1\
1\

D..

'\

(/)

(/)

' w

in

1\

CENTER POINT
OF ELLIPSES ~

<X:
io =

II

-L
I

r--.~
1'1

'\

(/)

/'

-=t\
v
\

ELLIPSE "A"

ELLIPSE "B"

....'

'1\-,

II

'1\

1\

1\

io

1/

'

II

(/)

.....

ELLIPSE "A"

.....'

I\

1/
1/

'

....'

\
io

.....'

I\

1/

ELLIPSE "B" _/

.......

....

i'--

1\

WII

io

~~

....
....'

~~

'

'

I'.

~~

1\
\

1/

'

Co

!I"

1'- 8"

1\
\

~lt

~ ,\

~~

....
....'

II

I
1/

& LANE

1\
1\

1/

1'- 0"

1'- 0"

2'- 4"
II

II

ELLIPSE A AXIS

TYPE 3l (LEFT)
TRAFFIC ARROW

TYPE 3R (RIGHT)
TRAFFIC ARROW
MIRROR IMAGE OF
TYPE 3L TRAFFIC ARROW

APPROVED FOR PUBLICATION

....

Harold J. Peterfeso

------=s~~T~ED~ES~IG~NE~NG=.IN~EE=R------

05-31-06
DATE

fJ'I Washington State Department of Transportation

7' - 0"
3'- 6"

LANE

1'- 6"

= 31- 111
(:::: 3.08')

'

Il l

1\

I
I
SYMBOL & LANE ~
CENTERLINE

\
\

r~

1'- 8"

Co

'

j'...

1\

1\

2'- 0"

'

\
\

I
I

lt

~~ ~~

17

,\

o.

1\

>

CP..
\

'

II

"''"
"'"

I
I

"''"
~

I
lo

r....

"' '\

ELLIPS~ "B"

'

ixl

'

I'\.

"'"

\.

1\

TYPE 6R (RIGHT)
TRAFFIC ARROW

ELLIPSE "A" -

,-

\
/

=
<(
ixl =
' w

en

If

lo

lo ~
' w

en

o.

0...

::J
....1

o.

en
0...

::J
....1
w

'I~

1\

MIRROR IMAGE OF TYPE 6L


(MIRRORED ABOUT LANE CENTERLINE)
(SHOWN AT REDUCED SCALE)

en

1\

1\

-<

[\

v
L

1\
\

MARKING AREA
35.88 SQ.FT.

1\

o.

!"

"

1~

SYMMETRICAL ABOUT V
CENTERLINE

CENTER POINT
OF ELLIPSES

I I

"''"

'

GRID IS 4" SQUARE


I

MARKING AREA
45.17 SQ.FT.
MARKING AREA
35.88 SQ.FT.

SYMBOL MARKINGS
TRAFFIC ARROWS FOR
HIGH SPEED ROADWAYS
STANDARD PLAN M-24.20-01
SHEET 3 OF 3 SHEETS

I
I

1'- 0"

1'- 0"

2' - 4" - ELLIPSE "A" AXIS

1'- 8"
I

TYPE 7 TRAFFIC ARROW

APPROVED FOR PUBLICATION

1'- 4"- ELLIPSE "B" AXIS

TYPE 6L (LEFT)
TRAFFIC ARROW

....

Harold J. Peterfeso
STATE DESIGN ENGINEER

05-31-06
DATE

fJ'I Washington State Department of Transportation

SYMBOL
& LANE

NOTE

It

1'- 4"

Use the dimensions shown on this plan for each type Traffic Arrow being
placed on roadways with a posted speed limit of 40 mph or lower.

(._s-

1'- 0"

SYMMETRICAL ABOUT
CENTERLINE

1'- 2"

2'- 4"

1'- 3"

I
SYMBOL
-~ &LANE

SYMBOL & LANE

It
1'- 8"

8"

1'- 0"

&,

'

/I\

1/

'

1'- 2"

'

'

/
1/
\

&,

TYPE1S
TRAFFIC ARROW

'

Co

[r- ELLIPSE "A"

r--..
I

v\

rv
I

'

1\

'1\-,

[/'

1-

1---

1\

L.U

'

~
L.U

(/)

c..

::::i

::::i

....1

L.U

CENTER POINT
OF ELLIPSES -

L.U

v V"

Co

(f),

-"
)

(/)

II

=
<(
Co =
(f),

il

/1
I

1/

L.U

~i-> (/)
c..
b

'

,_ 1/

::::i
....1

L.U

(/)

c..

::::i

1---

~
L.U

....1

L.U

0.,

I I I
GRID IS 4" SQUARE
I I I I

I I I

CENTER POINT
OF ELLIPSES

~~

__J_

1
8"
1'-6\

1'- 2"

II

ELLIPSE A \ _
AXIS

(/)

10"- ELLIPSE "B" AXIS

~
L.U

~i-> (/)
c..
b

'

~
L.U

::::i
....1

L.U

(/)

c..

::::i

'---

....1

L.U

MARKING AREA
14.83 SQ.FT.

;J

....

GRID IS 4" S~UARE


I I

1'- 2"

8"

10"- ELLIPSE "B" AXIS

8"

-~'-6"
II

8"

_/

TYPE 3SR (RIGHT}


TRAFFIC ARROW
MIRROR IMAGE OF
TYPE 3SL TRAFFIC ARROW
(SHOWN AT REDUCED SCALE)

MARKING AREA
14.83 SQ.FT.

MARKING AREA
7.73 SQ.FT.

-1

v- ELLIPSE "B"

1---

'

'

II

....1

10"- ELLIPSE "B" AXIS

1---

1\

!'--- 1---

MARKING AREA
12.86 SQ.FT.

v- ELLIPSE "A"
1---

"I~

~i-> (/)
c..

1'- 2"

"""' ~

/
1\

'

i->

=
<(
Co =
(f),

r-..

(/)

1\

1\
ELLIPSE "B"

"' \
' '
'

TYPE4S
TRAFFIC ARROW

i->

i\

17

1---"''\

'

I I

1/
.........

-~II

1/

'

pj-

I
GRID IS 4" SQUARE I I I

.....

\
1/\1\

CENTER POINT _
OF ELLIPSES

I/
r~

Co

i->

'

.....'
b

i->
.,....

1---

Co

1\ I I

1\

v
1/
J

Co

....

Co

~I

SYMBOL & LANE


CENTERLINE

'

....

ELLIPSE "B"

1'- 4"

1'- 4"
1'- 2"

'

MIRROR IMAGE OF
TYPE 2SL TRAFFIC ARROW
(SHOWN AT REDUCED SCALE)
MARKING AREA
8.03 SQ.FT.

i'-

<1

"\

....

1/

TYPE 2SR (RIGHT}


TRAFFIC ARROW

.....

.,....
'

1\

: 1/
'

v
\

1/

r---.

I
ELLIPSE "A"

v
Co

MARKING AREA
7.73 SQ.FT.

1\

It

IJ

ELLIPSE A

II

SYMBOL MARKINGS
TRAFFIC ARROWS FOR
LOW SPEED ROADWAYS
STANDARD PLAN M-24.40-01
SHEET 1 OF 2 SHEETS

AXIS

APPROVED FOR PUBLICATION

_/1'-6"
II

ELLIPSE A

II

AXIS

TYPE 2SL (LEFT} TRAFFIC ARROW

TYPE 3SL (LEFT} TRAFFIC ARROW

__
H_a_ro-;::;l=d=.l=.=P~et~e~m~e.=..s.:....o__ OS-31-06
.......

STATE DESIGN ENGINEER

DATE

fJ'1 Washington State Department of Transportation

LANE

SYMBOL & LANE

<t

<t
::::: 2'- 5/8"
(::::: 2.05')

- 8"

4'

1'- 0" 1

2'- 4"

t.v""

-,

1\

f--

SYMBOL & LANE ~


CENTERLINE

1'- 2"

1/
'

(<)
~

'

I
\

.....'

k'

I--

t--

I-- ___l_

t--

f--

~\-

I--

IS

I--

'

1-

f--

1-

f--

1-

f--

1-

f--

\
\

\ I v
~2-l .~,LIPSE

MARKING AREA
15.94 SQ.FT.

'---

I
ELLIPSE
"B"

\
1\

'\.

'

SYMMETRICAL ABOUT
CENTERLINE

b~ bL-

I
-

I
'-

I
f--

'

I--

I I I I

MIRROR IMAGE OF TYPE 6SL


(MIRRORED ABOUT LANE CENTERLINE)
(SHOWN AT REDUCED SCALE)

=
Co --<1:
'
w

(<) C/)

D..

::::i
....1

C/)

D..

::::i

rr.

....1

1/

'

8"

MARKING AREA
15.94 SQ.FT.

"'--- CENTER POINT


OF ELLIPSES

--+-

~~

I I I
GRID IS 4" SQUARE -

C/)

TYPE 6SR (RIGHT}


TRAFFIC ARROW

0~

II

(<)
N

C/)

'----- t--

'

(<)

0~

lo

*
~

F-.

....'

1'- 4"

....'

Co

1/' '-.....

'

Lo

f--

....

I ~

I
I

TYPE 6SL (LEFT}


TRAFFIC ARROW

8"

MARKING AREA
19.58 SQ.FT.

8"
1'-6\
II

1'- 2"

II

ELLIPSE A \ _
AXIS

10"- ELLIPSE "B" AXIS

MARKING AREA
23.14 SQ.FT.

TYPE 75 TRAFFIC ARROW

SYMBOL MARKINGS
TRAFFIC ARROWS FOR
LOW SPEED ROADWAYS
STANDARD PLAN M-24.40-01
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

Harold J. Peterfeso
-~----~ST~~~ED~ES~IG~NE~N~GIN~EE~R------

TYPE 5 TRAFFIC ARROW

f/'1

05-31-06
DATE

Washington State Department of Transportation

18'- 8"
....1
....1

LlJ

Cl
Cl

REVERSE CURVE ELLIPSES


ARE SYMMETRICAL ABOUT

::::i

0::

1'- 8"

LlJ
LL.

7'- 8"

-.------

5'- 0"

3'- 4"
1'- 4"

:;....'

......

'

-'

r---

-r--- r--r--..:.

r-- r-- r-:_'

lS.

!'--r-....
..............

'

1\

'\

Co

"

'

:;....

'

',

'

-- -

~ r--

r-....
1'- 4"

1. . . . . . . . . .

--" -

- --

JFl v r

r---.....

4' -7"

I~

4'- 1"

-1\

1---- '
''
'

..........-

(.:-

l.,..-

'

Cv>

1'--r-

r-- r-- t--

Ll--

---

r-- r-- r-

:--

~t-- 1

)....--,....-

f.-

b
'

Co

~ :--

Co

'

:;....

K=

3'- 4"

5'- 0"

1-~

CENTER POINT OF
ELLIPSES (TYP.)

:::: 5'- 6 7/8"

:;....'

'

2'- 0"

:::: 6'- 5 1/8"

I
I

3'- 0"

_.. v ~

A ---- +---

,.,.../

j_ t-- )....-- .....-

r---.....

'\J

~
v
I

1" -b,.li l l

::::2 7/8".1

1---

1\

-----

..........

"-..._

!'-...

--~1

cv

'

............

......... I

ffH

........ I

'

-.-----

/"

b.-...-

2'- 0"

GRIDS ARE 4" SQUARE

2'- 8"

ASSUME POINTS NOT DIMENSIONED


TO BE COINCIDENT WITH GRID LINES

1'
SCALE

DETAIL

TYPE TC

TYPE LTC

TYPETRC

TYPE LTRC

18.56 SQ.FT.

24.19 SQ.FT.

23.07 SQ.FT.

28.70 SQ.FT.

COMPONENT KEY
THE LABELED AREAS ABOVE CORRESPOND TO THE PORTIONS
NEEDED FOR EACH TYPE OF ROUNDABOUT TRAFFIC ARROW.

TYPET

TYPE LT

TYPE TR

TYPE LTR

15.07 SQ.FT.

20.69 SQ.FT.

19.58 SQ.FT.

25.20 SQ.FT.

FOR EXAMPLE: THE ROUNDABOUT TRAFFIC ARROW TYPE TRC


REQUIRES THE "COMMON", "T", "R", AND "C" AREAS.

PAVEMENT MARKING- ROUNDABOUT TRAFFIC ARROW

STANDARD PLAN M-24.50-00

LlJ

-~~

ROUNDABOUT TRAFFIC
ARROWS

- -

SHEET 1 OF 1 SHEET
COMMON

TYPE LC

ROUNDABOUT TRAFFIC ARROW TYPE TRC

18.07 SQ.FT.
CENTER THE ARROW ON THE LANE CENTERLINE BETWEEN THE
LATERAL EXTREMITIES OF THAT ARROW TYPE.

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

fll
.....

06-16-11

STATE DESIGN ENGINEER

DATE

Washington State Department o Transportation

NOTES

Cl
0::

11'- 6"- UNLESS NOTED

LL.

1. If Rumble Strips are present,


install marking outside of
the Rumble Strip.

"oTHERWISE IN CONTRACT

~
<(

en
::::i

LEDGE LINE

:;..:

CENTERLINE OF JUNCTION BOX,


r P U L L BOX OR CABLE VAULT

Ill

Cl

CENTERLINE OF
"-,(CROSS CULVERT

I-

(.)

----'~
'------

I-

(.)

--+-------'tj'-qp__--+'

w
w

.,-----L----9o---------=

en

EDGE LINE
EDGE LINE

~
n~
~~ ~~~T~

en
w

0::

J:
I-

ANGLE OF
CROSS CULVERT

(!)

....1

5'- 0"

PAVED
SHOULDER

PAVED
SHOULDER

MARKING AREA= 0.56 SQ. FT.

JUNCTION BOX,
PULL BOX OR
CABLE VAULT

MARKING AREA= 11.73 SQ.FT.

CROSS CULVERT

HALF-MILE MARKER

STOP LINE
MARKING AREA = 0.56 SQ. FT.

JUNCTION BOX, PULL BOX,


OR CABLE VAULT MARKINGS

LEDGE LINE

EDGE LINE

en

en:5

!:!:!a.
0::1-

~(.)

J:~

1-1(!)Z

zo
W(.)
_.w
w
en

\
CHEVRON OR DIAGONAL

H
~PAVED

SHOULDER

WHITE OR YELLOW - SEE CONTRACT PLANS

2'- 0"

PAVED
SHOULDER

SYMBOL MARKINGS
MISCELLANEOUS

MARKING AREA = 6.00 SQ.FT.

MARKING AREA = 1.06 SQ.FT.

STANDARD PLAN M-24.60-03

FULL MILE MARKER

DRAINAGE STRUCTURE INLET

SHEET 1 OF 2 SHEETS
APPROVED FOR PUBLICATION

CROSSHATCH MARKING
W = 8" FOR POSTED SPEED LIMIT OF 40 MPH OR LOWER
W = 12" FOR POSTED SPEED LIMIT OF 45 MPH OR HIGHER

AERIAL SURVEILLANCE MARKERS

DRAINAGE MARKING

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

SYMBOL MARKING

YIELD AHEAD SYMBOL

SYMBOL
& LANE

ct

GRID IS 4" SQUARE

3'- 0"

YIELD LINE SYMBOL

USE

MARKING AREA

TYPE 1

6'- 0"

2'- 6" 13'- 0"

N/A

LESS THAN 45 MPH

25.90 SQ.FT.

TYPE2

6'- 0"

3'- 0" 20'- 0"

N/A

45 MPH OR GREATER

36.54 SQ.FT.

LESS THAN 45 MPH

0.75 SQ.FT.

45 MPH OR GREATER

3.00 SQ.FT.

TYPE 1

1'- 0"

6"

1'- 6"

6"

TYPE2

2'- 0"

1'- 0"

3'- 0"

1'- 0"

TYPE2

2'- 0"

1'- 0"

3'- 0"

1'- 0"

MARKING AREA= 1.41 SQ.FT.

ROUNDABOUT ENTRY

3.00 SQ.FT.

MINIMUM OF 4 IN LANE

ACCESS PARKING SPACE SYMBOL


(MINIMUM)
11..

i=

l
1./

""'----

1---

1\
........

1""- . . . .

I.
GRID IS 4" SQUARE

iS
B

II
I
I

k:: \
7 \ \
4"

0::

'

Co

\ 1\
1/

{)

11..

Lo

'

\ \
v ~.j i-- ~

......v

3'- 0"

....1

w ~

(ot)

0::

1-

iS

IV

--

.I

SYMBOL
& LANE

ct

MARKING AREA = 3.09 SQ.FT.

YIELD LINE SYMBOL


(MULTIPLE SYMBOLS REQUIRED
FOR TRANSVERSE YIELD LINE
- SEE CONTRACT)

6'- 0"

ACCESS PARKING SPACE SYMBOL


(STANDARD)

MARKING AREA= 12.08 SQ.FT.

SPEED BUMP SYMBOL

c
~
......
......
......

M~

f
4"

Lo

'

'

Co
11..

....1

~
w

1-

....
'

Co

'

(ot)

3"

0::

iS

-=---......
......

1'- 2"

3'- 0"

1'- 2"

5'- 4"
TOTAL MARKING AREA= 28.44 SQ. FT.
WHITE= 9.76 SQ.FT.
BLUE= 18.69 SQ.FT.

SYMBOL MARKINGS
MISCELLANEOUS

Co

10"

2'- 0"

10"

STANDARD PLAN M-24.60-03

3'- 8"
TOTAL MARKING AREA= 13.44 SQ.FT.
BLUE = 8.62 SQ.FT.
WHITE = 4.82 SQ.FT.

ACCESS PARKING SPACE SYMBOL (STANDARD)

ACCESS PARKING SPACE SYMBOL (MINIMUM)

WITH BLUE BACKGROUND AND WHITE BORDER


(REQUIRED FOR CEMENT CONCRETE SURFACES)

WITH BLUE BACKGROUND AND WHITE BORDER


(REQUIRED FOR CEMENT CONCRETE SURFACES)

SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

YIELD AHEAD SYMBOL

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

TOP EDGE OF REFLECTIVE SHEETING

~n~

- w

"'w
'Z
"'"::5

'a::

~11i
:::!:Z
= w
m>
'0
MID
<C

~lli

REFLECTIVE
SHEETING

2'- 0" MIN.

:::!:0

NOTES

TOP EDGE OF REFLECTIVE SHEETING

= w
Mw

8'- 0" MAX.

BMount the shorter flexible guidepost onto the guardrail post.

:::!:Z

w
m>

(!)~

oO

en

2. Guideposts shall be fastened to the wooden guardrail post using two 2" x 3/8" lag screws
with washers, along centerline of post. Also acceptable is any approved attachment method
submitted by the guidepost manufacturer.

w::C

en

~g

w::C

3. Guideposts shall be fastened to the steel guardrail posts using two galvanized 2" x 3/8" bolts
with a washer on both sides, a lock washer, and nut. The nut shall be tightened to properly
compress the lock washer. The drilled holes in the guardrail post web shall be painted with
galvanizing repair paint as described in Standard Specification Section 8-11.3(1)C . Also
acceptable is any approved attachment method submitted by the guidepost manufacturer.

<C

FLEXIBLE GUIDEPOST
SURFACE MOUNT

~MANUFACTURER'S

FLEXIBLE GUIDEPOST
GROUND MOUNT

4.

'"BURY DEPTH
_ __L_t

Drive the flexible guidepost in line with the guardrail posts, or

0::

u..w
oo
w_.
(!)~
oO

'a::
~LiS

0::

u..w

oo
w_.

A.

(SEE CONTRACT)

'Z
"'"::5

(SEE CONTRACT)

REFLECTIVE
SHEETING

2'- 0" MIN.

8'- 0" MAX.

:::!:0

1. When the Contract Plans requires a guidepost with concurrent guardrail runs, the Contractor
shall either:

"'Y/Jll'--

When concrete barrier runs concurrent, the Contractor shall mount Barrier Delineators where
guideposts are required.
GUIDEPOST TYPE DEFINITIONS - REFLECTIVE SHEETING APPLICATIONS
TYPEW

TOP EDGE OF REFLECTIVE SHEETING

TYPEWW

TYPEY

TYPEYY

CD

EB

TOP EDGE OF REFLECTIVE SHEETING

REFLECTIVE
SHEETING

REFLECTIVE
SHEETING

SEE NOTE 1

FACING
TRAFFIC

SEE NOTE 2

-j

3"

f-

ro

WHITE

FACING
TRAFFIC

-j

3"

BACK
SIDE

f-

-j

3"

f-

FACING
TRAFFIC

-j

3"

FACING
TRAFFIC

f-

-j

3"

f-

BACK
SIDE

-j

3"

f-

TO tiD 1TO 1TO 1TO

!D
4" WHITE

WHITE

YELLOW

YELLOW

YELLOW

WHITE

FLEXIBLE GUIDEPOST

FLEXIBLE GUIDEPOST

GUARDRAIL MOUNT

GUARDRAIL MOUNT

(USE FOR WOODEN GUARDRAIL POSTS)

(USE FOR STEEL GUARDRAIL POSTS)

REFLECTIVE SHEETING,
OR FLAT PLASTIC
REFLECTOR LENS

BARRIER DELINEATOR REQUIREMENTS


Spacing of Barrier Delineators shall be as shown in the Plans.

HOUSING OR BRACKET

The housing or bracket can be flexible or rigid, molded from a durable plastic or other durable material approved
by the engineer, and shall be attached to the barrier with an adhesive recommended by the manufacturer. The
attachment point on the barrier surface shall be free of dirt, curing compound, moisture, paint, or any other matter
that would adversely affect the adhesive bond.

REFLECTIVE SHEETING,
OR FLAT PLASTIC
REFLECTOR LENS
HOUSING OR BRACKET

Barrier Delineators shall be one-sided for single direction traffic, or two-sided for bi-directional traffic. Color shall
be white on the right of traffic, and yellow on the left of traffic.

GUIDEPOSTS AND
BARRIER DELINEATORS

The reflective surface shall be rectangular or trapezoidal.

STANDARD PLAN M-40.10-02

Reflective Sheeting: 12 square inches minimum surface area; Type Ill, IV, V, or VI, selected from approved
materials listed in the Qualified Products List.
Plastic Reflector: 9 square inches minimum surface area;
acrylic or polycarbonate conforming to AASHTO M 290.
Reflectors shall equal or exceed the following minimum
values of Specific Intensity:

OBSERVATION
ANGLE

ENTRANCE
ANGLE

0.1

oo

0.1

20

SHEET 1 OF 1 SHEET

SPECIFIC INTENSITY

(cd/ft-c)
WHITE

YELLOW

126

75

50

30

SIDE MOUNT
PER CONTRACT

TOP MOUNT
PER CONTRACT

BARRIER DELINEATORS
(CONCRETE BARRIER TYPES AND LOCATIONS VARY, SINGLE SLOPE IN MEDIAN SHOWN)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

NOTES
1. See Standard Plan M-40.1 0 for Guide Post details. See plans for guide post
requirements between interchanges.
2. Guide posts shall be placed at 100' spacing on ramp tangents and tapers.

LEGEND

TYPEW

TYPEY

3. "S" dimension shown on Standard Plan M-40.40 or 100', whichever is smaller.


4. One half of "S" dimension shown on Standard Plan M-40.40 or 50', whichever
is smaller.
5. Two spaces at 100'.

SEE TYPE DEFINITIONS,


STD. PLAN M-40.1 0

6. Three equal spaces when R < 75', four equal spaces when R::!: 75'.
7. Two equal spaces.
8.

Locate the initial Guide Post so that it does not hinder the visibility of the
Bridge Delineator for approaching traffic. The distance between the bridge
end and the initial Guide Post shall be 50 feet maximum.

NOTE 5

NOTE B (TYP.)

NOTE 1

~r

1-

NOTE 1

NOTE4

GUIDE POST PLACEMENT


INTERCHANGES
STANDARD PLAN M-40.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

10-12-07
DATE

fJ'I Washington State Department of Transportation

NOTE
See Standard Plan M-40.1 0 for Guide Post details.

THREE EQUAL SPACES


WHEN R < 75'

:x:>YUR EQUAL SPAC/ES WHEN R 0!: 75'

~_

(/)

__.1.,.00.__''"'.'DE":'"C,_...E.._,LE":'.RA_.._.._TI-=O_._.N_:_T:..:.AP:....::E=-R'----_ _

"I"

40'

"'

I.

y
___!_-------

CD

100' (TYP.)

200'
500'

DIVIDED HIGHWAY

e
y

REFLECTIVE SHEETING APPLICATIONS


TYPE G1

TYPE G2

()

ct

G1

LEGEND

TYPEW

CD

TYPEWW

TYPEY

r-

BACK
SIDE

-1

r-

To +IO
L
3"

3"

4" VMITE

SEE TYPE DEFINITIONS,


STD. PLAN M-40.10

t0

Io ~-ITE
v.<ITE

GREEN

FOUR EQUAL SPACES WHEN R 0!: 75'

G2

FACING
TRAFFIC

-1

yx:

THREE EQUAL SPACES


WHEN R < 75'

FACING
TRAFFIC

-1

r-

To
3"

BACK
SIDE

-1

3"

r-

1 +T-O
VMITE

to

4" v.<ITE

+WHITE
4"

IO

GREEN

y
R

()

G2

G1

ct

()
G1

G2

GUIDE POST PLACEMENT


GRADE INTERSECTIONS
STANDARD PLAN M-40.30-00
SHEET 1 OF 1 SHEET

j ~e

APPROVED FOR PUBLICATION

UNDIVIDED HIGHWAY
WITHOUT ILLUMINATION

....

Pasco Bakotich Ill

09-20-07
DATE
.
Department of Transportation

STATE DESIGN ENGINEER

fJ'I Washington State

s
;:2
...,

GUIDE POST SPACING


(FEET)

:::>

CJ)

0:::

RADIUS

<t:

::!!:
:;,..:

50

20

III

115

25

150

30

200

35

250

40

300

50

400

55

500

65

600

70

700

75

800

80

900

85

1,000

90

1,200

100

1,700

120

2,300

140

2,900

160

3,700

180

4,500

200

5,500

220

6,500

240

7,600

260

8,800

280

10,000

300

R>10,000

300

PT

NOTES

1. The first guide post is positioned "S" distance from the


beginning of curvature.
PC

2. If the last guide post beyond the curve is 1/2 "S" or more,
no additional posts are required.
3. If the last guide post beyond the curve is less than 1/2 "S",
one additional post is required.
TWO-WAY UNDIVIDED HIGHWAYS

4. See Standard Plan M-40.1 0 for Guide Post details.

GUIDE POSTS ON OUTSIDE OF CURVE


IN DIRECTION OF TRAVEL

LEGEND

INTERPOLATE FROM THE


TABLE FOR RADII NOT SHOWN

TYPEW

CD

TYPEWW

TYPEY

SEE TYPE DEFINITIONS,


STD. PLAN M-40.10

NOTE2

s
0

---

NOTE 1

_/r

GUIDE POST PLACEMENT


HORIZONTAL CURVES

PC
1/2

STANDARD PLAN M-40.40-00

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

MULTI-LANE DIVIDED HIGHWAYS


GUIDE POSTS ON INSIDE AND OUTSIDE OF CURVE
FOR EACH DIRECTION OF TRAVEL

....

Pasco Bakotich Ill

------~S~~~TE~D~ES=IG~NE~NG~IN~E=ER~----

09-20-07
DATE

fJ'I Washington State Department of Transportation

I.SEE NOTE 1 [TYP.)

LEGEND

0
riiiiiiL

--

--

--

--

--

--

--

--

--

--

TYPEW

CD

TYPE lfiMI

TYPEY

riiiiiL

--

--

--

--

--

--

--

--

--

...

..

SEE TYPE DEFINITIONS,


STD. PLAN M-40.10

--

~ ~

NOTES
1. Locate the initial Guide Post so that it does not hinder the visibility of the Bridge
Delineator for approaching traffic. The distance between the bridge end and
the initial Guide Post shall be 50 feet max.

DIVIDED HIGHWAY

2.

Locate the initial Guide Post so that its visibility is unhindered for traffic departing
the brid g e. The distance between the bridge end and the initial Guide Post shall
be 50 feet max.

3. See Standard Plan M-40.1 0 for Guide Post details.

I.
CD

100' (TYP.)

CD

I"SEE NOTE 2 (TYP.)

CD

CD

CD

CD
riiiiiiL

--

--

CD

CD

--

--

--

CD

--

--

CD
SEE NOTE 1 (TYP.)

~ ~

--

CD

CD

--

..

--

GUIDE POST PLACEMENT


BRIDGES
STANDARD PLAN M-40.50-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

UNDIVIDED HIGHWAY

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

09-20-07
DATE

fJ'I Washington State Department of Transportation

NOTE
See Standard Plan M-40.1 0 for Guide Post details.

CROSSOVER

<t
100'

100'

100'

100'

LEGEND

MEDIAN CROSSOVERS

TYPEW

TYPEY

SEE TYPE DEFINITIONS,


STD. PLAN M-40.10

~--------~0~----~o~----(o~---

----o------o------co)-1

f.

100 (lYP.>

TAPER

LANE REDUCTIONS

GUIDE POST PLACEMENT


MISCELLANEOUS
STANDARD PLAN M-40.60-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

....

Pasco Bakotich Ill


STATE DESIGN ENGINEER

09-20-07
DATE

fJ'I Washington State Department of Transportation

(4)

'"'

''
'

''

''

'

'

''

''

'

'

''

'

''

''

'
'

'
'

~/
o::'
~:

;:y,'
''

'
''

7" 1/2"

16"

I.

.I

1/2" MIN.

15/8"

MAX.

SECTION

SECTION

ISOMETRIC VIEW

TYPICAL SHOULDER INSTALLATION

MEDIAN SHOULDER

OUTSIDE SHOULDER

SHOULDER
RUMBLE STRIP

SHOULDER
RUMBLE STRIP

PERSPECTIVE VIEW

SHOULDER RUMBLE STRIP


TYPE 1
FOR DIVIDED HIGHWAYS
STANDARD PLAN M-60.10-01
SHEET 1 OF 4 SHEETS

MULTI-LANE DIVIDED HIGHWAY

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

BEGIN RUMBLE STRIP ON


RIGHT SHOULDER AT END
OF WIDE LANE LINE

SHOULDER RUMBLE STRIP


ON LEFT SHOULDER

--

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

END RUMBLE STRIP ON RIGHT


SHOULDER AT BEGINNING OF
DECELERATION TAPER

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

WIDE LANE LINE

TWO-LANE OFF-CONNECTION

BEGIN RUMBLE STRIP ON


RIGHT SHOULDER AT END
OF WIDE LANE LINE

SHOULDER RUMBLE STRIP


ON LEFT SHOULDER

---:D:DDD:DD:DDD:DD:DD:DDD:DD:DDD:DD:DDD:DD:DDD:DD:DD:DDD:DD:DDD:DD:DDD:DD:DDD:DDS~~=~~~~~~~~~~=~=======~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~;~~;;;;;;;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
END RUMBLE STRIP ON RIGHT
SHOULDER AT BEGINNING OF
DECELERATION TAPER
WIDE LANE LINE

SINGLE-LANE OFF-CONNECTION

BEGIN RUMBLE STRIP ON


RIGHT SHOULDER AT END
OF WIDE LANE LINE

SHOULDER RUMBLE STRIP


ON LEFT SHOULDER

--

DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

ENDRUMBLEST:~:~:ooo:oo:~:~:~:oGoo:~:~:oo:ooo:oo:ooo:oo:oo~ooo~oo;oooLoo~============~~~~~~~~========~==~~==========~~
~~

SHOULDER AT BEGINNING OF
DECELERATION TAPER

WIDELANELINE

SHOULDER RUMBLE STRIP


TYPE 1
FOR DIVIDED HIGHWAYS
STANDARD PLAN M-60.10-01
SHEET 2 OF 4 SHEETS

SINGLE-LANE OFF-CONNECTION
FOR ONE LANE REDUCTION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

SHOULDER RUMBLE STRIP


ON LEFT SHOULDER

--

--

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

BEGIN RUMBLE STRIP ON


RIGHT SHOULDER AT END
OF ACCELERATION TAPER
WIDE LANE LINE

END RUMBLE STRIP ON


RIGHT SHOULDER ADJACENT
TO BEGINNING OF ON RAMP
WIDE LANE LINE

SINGLE-LANE ON-CONNECTION

---

--

SHOULDER RUMBLE STRIP


ON OUTSIDE SHOULDER

,
--

--

--

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

--

450'

600'

--

--

- r--

--

--

:\

f.

--

--

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]~[][][][]

>-

SHOULDER RUMBLE STRIPS


ON MEDIAN SHOULDERS

DDDDDooooooooDooooooooDooooooooDoooDooooooooDooooooooDoooolommo

--

--

--

--

--

[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]

SHOULDER RUMBLE STRIP


ON OUTSIDE SHOULDER

_/

450'

600'

MEDIAN CROSSOVER

SHOULDER RUMBLE STRIPS


;(

STRUCTURE OR OTHER FEATURE NECESSITATING


('
A REDUCTION IN SHOULDER VI/10TH
"'\

DDDDDDDDDDDDDDDDDDDDDDDDDDDDD~D,DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD~DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDDDDDDDDDDDDDDDD:+

4' MIN.5' MIN. WITH BARRIER /


OR GUARDRAIL AT
EDGE OF SHOULDER

~1-------~

100' MIN.

MEDIAN SHOULDER

(RUMBLE STRIPS SHALL NOT BE PLACED


ON BRIDGE APPROACH SLABS)

----------1

SHOULDER TAPER DETAIL

_,~------~1
7

r-1.,_________6_0'_M_I_N_._
OUTSIDE SHOULDER

~DDDDDDDDDDDDDDDDDDDDDDDDDD

~ ~: ~:~: ~TH

BARRIER
OR GUARDRAIL AT
EDGE OF SHOULDER

SHOULDER RUMBLE STRIP


TYPE 1
FOR DIVIDED HIGHWAYS
STANDARD PLAN M-60.10-01
SHEET 3 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

Cl

<5
0::
0::

c:r-----------

------------))

TERMINATE THE SHOULDER RUMBLE STRIPS AT


THE BEGINNING OF THE DECELERATION TAPER.
IF A MEDIAN ACCELERATION TAPER IS INCLUDED, START
THE RUMBLE STRIP AT THE END OF THE TAPER.

TAPER
TAPER

--

1000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000

1000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000

00000000000000000000000

00000000000000000000000

000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000

0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000

TAPER

TERMINATE THE SHOULDER RUMBLE STRIPS AT


THE BEGINNING OF THE DECELERATION TAPER.

..

IF A MEDIAN ACCELERATION TAPER IS INCLUDED, START


THE RUMBLE STRIP AT THE END OF THE TAPER.

6------------

RADIUS POINT OF RIGHT


TURN RADIUS (TYP.)

RUMBLE STRIP PLACEMENT AT INTERSECTIONS

SHOULDER RUMBLE STRIP


TYPE 1
FOR DIVIDED HIGHWAYS
STANDARD PLAN M-60.10-01
SHEET 4 OF 4 SHEETS
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

....1
....1

0
0

::::i

z
c:::

I
I
I

II
I

I
I
I

11..

I
I
I

~,'

::E,'
0:,'
I
I
I

I
I
I
I
I
I
I

I
I
I
I

5"

1/2"

12"- TYPES 2 AND 4

F\

16"- TYPE 3

3/8"

UNIT SECTION

..

3/8"

I~

UNIT SECTION

ISOMETRIC VIEW

TYPICAL SHOULDER INSTALLATION

SHOULDER

SHOULDER

SHOULDER RUMBLE STRIP

SHOULDER RUMBLE STRIP

PERSPECTIVE VIEW

SHOULDER RUMBLE STRIP


TYPES 2, 3, AND 4
FOR UNDIVIDED HIGHWAYS
STANDARD PLAN M-60.20-02
SHEET 1 OF 2 SHEETS

UNDIVIDED HIGHWAY
(TYPE 4 PATTERN SHOWN)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-27-11
DATE

Washington State Department of Transportation

....1
....1

---~~-----~-M-IL_L_E_D_u_N_rr_s_ _ _ _ _~I1_J_'_o_R_1_6_'G_A_r~~-----4-B-M-IL_~_D_u_N_rr_s_ _ _ _ _.+l__~rEOOE~~~~OOWffi-~

0
0

::::i

z
c:::

DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

11..

EDGE LINE
0

DDDDDDDDDDDDDDDDDDDDDDDD DDDDDDDDDDDDDDDDDDDDDDD

Q------------

c:::
0

SHOULDER
RUMBLE
STRIPS

DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

------------Q

DDDDDDDDDDDDDDDDDDDDDDDD DDDDDDDDDDDDDDDDDDDDDDD

EDGE LINE
DDDDDDD

TYPE 2 TYPE 3 -

EPS

12' GAP AND 12" WIDE STRIP


16' GAP AND 16" WIDE STRIP

MAJOR ROAD

-~~--2_B_M_I_~_E_D_U_N_rr_s__.+._1_2_'G_A_P_.+_._2_B_M_IL_L_E_D_U_N_rr_s__~~-1_2_G_A_P_.+1 . ~_M_IL-L-ED_U_N_rr_s_~~~rEDGEOF~~SHOUWffi-~S
_ _

DDDDDDDDDDDDDDDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDDDDDDDDDDDDDD

TERMINATE SHOULDER RUMBLE STRIPS


40' MINIMUM FROM THE BEGINNING OR
END OF EACH RIGHT TURN RADIUS.

DDDDDDDDDDDDDDD

DDDDDDDDDDDDDDDD

EDGE LINE

DO DDDDDDDDDDDDDDDDDDDDDDDDD

0
' ------------

SHOULDER
===PRUMBLE
STRIPS

TERMINATE SHOULDER RUMBLE


STRIPS AT THE BEGINNING OR END
OF EACH RIGHT TURN TAPER.

- ----------- ~ RADIUS POINT OF RIGHT


TURN RADIUS (TYP.)

DO DDDDDDDDDDDDDDDDDDDDDDDDD

EDGE LINE

TYPE 4 -

SHOULDER\

G)

12" WIDE STRIP

l>,,

60' MIN

DDDDDDDDDDDDDD~

G)

/f//

STRUCTURE OR OTHER FEATURE


NECESSITATING
A REDUCTION IN SHOULDER WIDTH

100' MIN.

100' MIN

//J/~

DDDDDDDDDDDDDDDDDDDDDDD~DDDDDDDDDDDDDDDDDDDDDDDDDDD~
=

RUMBLE STRIP PLACEMENT


AT INTERSECTIONS

EPS

RUMBLE STRIPS SHALL NOT


BE PLACED ON BRIDGE
APPROACH SLABS

~DDDDDDDDDDDDD
=

s HOULDER
RUMBLE
s TRIPS (TYP.)

~DDDDDDDDDDDDDDDDDDDDDDD~DDDDDDDDDDDDDDDDDDDDDDDDDDD

60' MIN.

<t

\__SHOULDER

G)

SHOULDER RUMBLE STRIP


TYPES 2, 3, AND 4
FOR UNDIVIDED HIGHWAYS
STANDARD PLAN M-60.20-02
SHEET 2 OF 2 SHEETS
APPROVED FOR PUBLICATION

G)

NOT LESS THAN 4' - PROVIDE 5' WHEN


BARRIER OR GUARDRAIL IS PLACED
AT EDGE OF SHOULDER

Pasco Bakotich Ill

SHOULDER TAPER DETAIL

.....

fll

STATE DESIGN ENGINEER

06-27-11
DATE

Washington State Department of Transportation

NOTES

....1
....1

II

''''

Cl
Cl

1. Centerline Rumble Strip installation requires a minimum distance


of 12 feet from Centerline to edge of paved shoulder.

::::i

0::

2. When directed by the Engineer, Rumble Strips may be installed


along the turn pocket taper where there is a history of rear-end
collisions in the turn pocket.

LL.

'

i/
.

'

''

()f,''

Cl

'

~'

7" 1/2"

12"

I.

1/2" MIN.

15/8"

MAX.

.I

f
ISOMETRIC VIEW

TYPICAL INSTALLATION
SECTION

SECTION

CENTERLINE

'

I"

12'- 0" MIN. 112'- 0" MIN.

SEEN~TE

.I

DOUBLE CENTERLINE

SHOULDER

SHOULDER

NO-PASS LINE

CENTERLINE

CENTERLINE
RUMBLE STRIP
STANDARD PLAN M-65.10-02
SHEET 1 OF 2 SHEETS

PERSPECTIVE VIEW

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

UNDIVIDED HIGHWAY

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

....1
....1

Cl
Cl

RUMBLE STRIP OPTIONAL - SEE NOTE 2

::::i

0::

LL.

Cl

INSTALL RUMBLE STRIP


TERMINATE AT END OF LEFT TURN
CHANNELIZATION STRIPING

INTERSECTION WITH LEFT TURN CHANNELIZATION

OMIT CENTERLINE RUMBLE STRIPS IN THIS AREA


25'
APPROX. MIDWAY

OMIT CENTERLINE RUMBLE STRIPS IN THIS AREA

~ BETWEEN MILLED

1
-

0"

RECESS LENGTH

GROOVES

25'

I
:::::: 1

1
-

0"

JJ~ RUMBLE~.)

BRIDGE APPROACH SLAB

I)
BRIDGE

"""""\

REFER TO STANDARD PLAN M-20.30 FOR


RECESSED PAVEMENT MARKER DETAIL

RAISED PAVEMENT MARKER


WHEN SPECIFIED IN CONTRACT

\ _ RUMBLE STRIP (TYP.)

RECESSED PAVEMENT MARKER

0000[

WHEN SPECIFIED IN CONTRACT

LONGITUDINAL MARKING (TYP.)

BRIDGE

J:
__.()

~<5
zw ll.
ll.

1- 0::

Q
LONGITUDINAL MARKING (TYP.)

LONGITUDINAL MARKING (TYP.)

<(

(/)Cl

<(

o::o
0::

0000000000000000000000000000000#@~~~000000000000000000000000000000

][

~DDDDDDDDD~DDDDDDDDD~DDD

DDD~DDDDDDDDD~DDDDDDDDD~

CENTERLINE
RUMBLE STRIP

RUMBLE STRIP USAGE AS


DIRECTED BY ENGINEER

NON-COMMERCIAL ROAD APPROACHES AND DRIVEWAYS

STANDARD PLAN M-65.10-02

TERMINATE RUMBLE STRIP AT


BEGINNING AND END OF
APPROACH OR INTERSECTION

6-----------

__________ _v

SHEET 2 OF 2 SHEETS
RADIUS POINT (TYP.)

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

UNCHANNELIZED INTERSECTIONS
AND COMMERCIAL ROAD APPROACHES

.....

fll

STATE DESIGN ENGINEER

05-11-11
DATE

Washington State Department of Transportation

TRAFFIC

TRAFFIC

LANE

LANE

NOTE

VEHICLE
WHEEL PATH

1. Typically, four times the letter or numeral height - minimum,


up to ten times - maximum, or according to Plans.

J:
(!)en
-c:::
J:L.U

J:en

~c:::

= ~
'..J
Co

J: L.U

b~

TRAFFIC

Co..J

LANE

oL.U

OL.U

LANE
VEHICLE
WHEEL PATH

VEHICLE
WHEEL PATH

L.U

TRAFFIC

L.U

1-

1-

L.U
L.U

L.U
L.U

en

en

:r:en
(!)..J

J:en

J:~

~c:::

J: L.U

b~
,L.LJ

L.U

:r:en

0:::!:

~c:::

'::J

eoz

Co..J

J:L.U

b~
,L.U

J:en

Co..J

~c:::

J: L.U

b~
,L.LJ

EDGE
LINE

Co..J

1'- 10"

EDGE
LINE

L.U

1-

MAX.

HIGH-SPEED APPLICATION
HIGH-SPEED APPLICATION

L.U
L.U

en

L.U

bz

TRAFFIC

L.U
L.U

LANE

en

I'" VEHICLE HI

TRAFFIC
LANE
VEHICLE
WHEEL PATH

J:

~;;:

J:O

b~
,<(

Co

J:

~;;:

:r:o
= c:::
00:::

J:en
~c:::

J:en

= 101-

EDGE
LINE

~c:::

J:L.U

-' <(
N
.,....

J:L.U

b~

oL.U

,L.U

Co..J

Co..J

L.U

L.U

1-

1-

EDGE
LINE

LOW-SPEED APPLICATION

L.U
L.U

L.U
L.U

en

en

HIGH-SPEED APPLICATION

J:en
(!)..J

J:en
~c:::

J:~

J:L.U

b~
::::l
eoz

1-

0I,L.U

Co..J

TRAFFIC LETTER AND


NUMERAL APPLICATIONS
STANDARD PLAN M-80.10-01
SHEET 1 OF 2 SHEETS

3' - 3" 3' - 3"


MIN.

I MIN.

EDGE
LINE

EDGE
LINE

1'- 10"

MAX.
LOW-SPEED APPLICATION

LOW-SPEED APPLICATION

APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

TRAFFIC

TRAFFIC

LANE

LANE

VEHICLE
WHEEL PATH

VEHICLE
WHEEL PATH

TRAFFIC

TRAFFIC

LANE

LANE

I"

VEHICLE I
WHEEL PATH

TRAFFIC

t (!

LANE

::c
C!>rn
-o::
::cw

"I

VEHICLE
WHEEL PATH

::c
(!)rn
-0::

VEHICLE
WHEEL PATH

::cw
= ~
ow

.__.

Co

1-

0fW

::c
(!)

:c
b

'
Co

0....1

w
0

I-

1-

w
w

w
w

rn

rn
LANE

~
EDGE
LINE

EDGE
LINE

:ern

Qo::
::cw

= 101-

,w
Co_.

::c
(!) rn
:c 0::w
b

u
LANE
LINE

i(_EDGE

EDGE
LINE
HIGH-SPEED APPLICATION

' w
Co ....1

LINE
HIGH-SPEED APPLICATION
TRAFFIC
LANE

TRAFFIC

LANE

I' VEH:CLE 'I


:ern

Q 0::
::c w
b~
.w

::c
(!)rn

-o::
::cw

Co_.

= ~
ow
.__.

1-

w
w
rn

Co

bz

w
0

1-

w
w

rn

CD

w
w

..t

rn
:ern

....1~

O:E

::c w
b~
,w

Cl

.w

cO

STANDARD PLAN M-80.10-01

~ 0::

SHEET 2 OF 2 SHEETS

<(
....1

>-

HIGH-SPEED APPLICATION

I-

w
w

LL.

APPROVED FOR PUBLICATION

0::

EDGE
LINE

Pasco Bakotich Ill

EDGE
LINE
LOW-SPEED APPLICATION

TRAFFIC LETTER AND


NUMERAL APPLICATIONS

w 1::cl/)

Co_.

EDGE
LINE

Qo::
::cw

<(

= 10I-

Co_.

~ ~
rna..

:ern

Q 0::

Ill

HIGH-SPEED APPLICATION

......
fll

STATE DESIGN ENGINEER

06-03-11
DATE

Washington State Department of Transportation

....1
....1

Cl
Cl

r-.

1\

::::i

0::

w
LL.

I ll

::ccn
Q 0::
:I: w

II

= 1-

Cl

0I-

,w

I
-

rw

1\ 1/

1/

-CX)

....1

1-

1\ /

1/

- I-

- I-

17

r- r- - 1-

::ccn
:I: w

Q 0::

= 1-

0I-

,w

CX)

....1

!I"

1--1 -

--

~~

::ccn

"....I
5:~
=

0:::!:

'::J

CioZ

TRAFFIC LETTERS AND


NUMERALS
(HIGH SPEED ROADWAYS)
STANDARD PLAN M-80.20-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

EIGHT FOOT HIGH LETTERS AND NUMERALS


ARE SHOWN ON A FOUR-INCH SQUARE GRID
FOR USE ON ROADWAYS WITH A POSTED SPEED OF 45 MPH OR MORE

Pasco Bakotich Ill


06-10-08
----------------------STATE DESIGN ENGINEER
DATE

.....

fll

Washington State Department of Transportation

....1
....1

Cl
Cl

::::i

0::

LL.

'

Cl

f\-

'

SIX FOOT HIGH LETTERS AND NUMERALS SHOWN ON A THREE -INCH SQUARE GRID

/\

7!-

'

I
I

/ I\

1\
I \

/ r-

\
\
I

1\

r-

J:

r-

r-

r-

r-

J: w
= 101-

r-

r-

(:)....I

(!)en
- 0::

'W

\
\

r-

r- /

\
\/

\ 1/
\

/ \

\
\

I
I

-- -

--

~ r-

......

\ I
\I

\ I/
I

\
\

I
I

./

TRAFFIC LETTERS AND


NUMERALS
(LOW SPEED ROADWAYS)
STANDARD PLAN M-80.30-00

TEN FOOT HIGH LETTERS SHOWN ON A FIVE- INCH SQUARE GRID

SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION

Pasco Bakotich Ill

.....

FOR USE ON ROADWAYS WITH A POSTED SPEED OF 40 MPH OR LESS

fll

STATE DESIGN ENGINEER

06-10-08
DATE

Washington State Department of Transportation

Вам также может понравиться