Вы находитесь на странице: 1из 9

Compute the instantaneous and the average power dissipated by

the load. (w=314rad/s)

4
Load
9.6mH

Suppose that the electricity in your home has gone out and the
power company will not be able to have you hooked up again for
several days. You need to run the freezer, air-conditioner and the
refrigerator. When the appliances are on, they draw the following
currents (all values are rms):
Air conditioner :
Freezer:
Refrigerator:

9.6 A@ 120 V
pf = 0.90 (lagging)
4.2A@ 120 V
pf = 0.87 (lagging)
3.5 A@ 120 V
pf = 0.80 (lagging)

In the worst-case scenario, how much power must an emergency


generator supply?

Use the definition of complex power to calculate the real and


reactive power for the load. Repeat the calculation when the
inductor is removed from the load. Compare the real power transfer
between the source and the load for two cases.
4
Load
Vs=110V
~

10

19mH

Compute the complex power for the load and calculate the value of
the capacitance which will be connected in parallel to the load to
correct the power factor to unity

50
Vs=117V
~

j86.7

Load