Вы находитесь на странице: 1из 12

1er Procedimiento

Tramo
A
B

Qt
0.35
0.70

Wc (v)
0
0

%
100
100

Qut
0.35
0.70

Tramo
N

Qt
0.20
0.40

Wc (v)
1
2

%
100
90

Qut
0.2
0.36

Metodo De La Perdida De Carga J


Tramo
A
B
C
D
E
F
G
H
G
H
I
J
K
L
M
N

Q
0.35
0.70
0.70
0.70
0.70
1.28
0.40
0.72
0.40
0.72
1.28
1.71
1.71
1.71
0.32
0.20
0.36

1
1
1
1
1
1
1
1
1
1
1

1
1
1

D
1/4"
1/4"
1/4"
1/4"
1/4"
1/2"
1/4"
1/4"
1/4"
1/4"
1/2"
2"
2"
2"
1/4"
1/4"
1/4"

V
0.365
0.729
0.729
0.729
0.729
0.984
0.416
0.729
0.416
0.729
0.984
0.800
0.800
0.800
0.333
0.208
0.395

J
0.0103
0.0346
0.0346
0.0346
0.0346
0.0486
0.0130
0.0346
0.0130
0.0346
0.0486
0.025
0.025
0.025
0.0088
0.0039
0.012

1.75

2"

0.848

0.0276

1er Procedimiento

Tramo
G
H

Qt
0.40
0.80

Wc (v)
1
2

%
100
90

Qut
0.40
0.72

Tramo
C
D
E
F
I
J
K
L
M
O

Qt
0.70
0.70
0.70
1.42
1.42
2.14
2.14
2.14
0.36
2.50

Wc (v)
0
0
0
2
2
4
4
4
2
6.00

%
100
100
100
90
90
80
80
80
90
70

Qut
0.7
0.7
0.7
1.278
1.278
1.712
1.712
1.712
0.324
1.75

Qut=

1.75

J*L
0.0303
0.1349
0.0744
0.1979
0.2443
0.0165
0.0382
0.1349
0.0382
0.1349
0.2279
0.0085
0.1055
0.3658
0.0523
0.0115
0.0468

K
1
1.5
2
1
1.5
1
1
1.5
1
1.5
1.5
1
1
1.5
1.5
1
1.5

(J*L+
0.037
0.176
0.129
0.225
0.285
0.066
0.047
0.176
0.047
0.176
0.302
0.041
0.138
0.415
0.061
0.014
0.059

o De La Perdida De Carga J
L
2.94
3.90
2.15
5.72
7.06
0.34
2.94
3.90
2.94
3.90
4.69
0.34
4.22
14.63
5.94
2.94
3.90

0.007
0.041
0.054
0.027
0.041
0.049
0.009
0.041
0.009
0.041
0.074
0.033
0.033
0.049
0.008
0.002
0.012

1.72

0.0475

0.000
H=

0.047
2.439

Datos caculado
H=
10.74
J=
0.03
Ltotal=
274.55
P1/
6.153

Comprobacion
Po/
14.06
Z
6.7
P1/
4.92 ok!

Intalaciones de Evacuacion Agua Residuales


Colector Secundario 1
Tramo
U/D
Diametro
A
3
50
B
6
50

Colector Secundario 3
Tramo
U/D
Diametro
A
1
35
B
5
80
C
7
80
D
10
80

A
B
C
D
E
F

colectores principales
Tramo
U/D
Diametro
6
40
6
40
16
100
26
100
26
100
35
100

Diametro
40
80
80
80

Columna De Ventilacion
U/D
Longitud
6
7.20
10
7.20
10
7.20
9
7.20

D.C.
1 1/4"
1 1/2"
1 1/2"
1 1/2"

Colector Secundario 2
Tramo
U/D
Diametro
A
2
50
B
6
80
C
9
80
35
D
1
E
10
80
Colector Secundario 4
Tramo
U/D
Diametro
A
2
40
B
4
50
C
5
80
D
9
80

Diseo de Bomba de abastecimiento de tinaco


Q
N. Ciclo
Tiempo

8.25L/seg
5llenada/h
12min.

720seg

Consumo
8.25L/seg
Vol. De Dep. (8.25L/seg)*(720seg)

0.00825mts/seg
5940Lts/3.79gls

Potencia

(8.25*78)/(.90)*(75)

(Q*H)/(EF)*(75)

1567.28gls
9.53

Cisterna

Bomba 10hp

1600gls
10Hp

mba 10hp

1600gls

Deposito

Sistema de agua caliente

Detalles
Banera
Lavamano
Lavadero
Fregadero

T.m
T.F
T.C
A
V
C

Cantidad

Consumo
3
4
2
2

Cantida * consumo
180
540
12
48
80
160
20
40
A=
788

Leyenda
Temperatura de mezcla
Temperatura agua Fria
Temperatura agua Caliente
Consumo de Aparato
Volumen de agua mezclada
Caloria

volumen del Tanque


V=((T.M-T.F)/(T.C-T.F))*A
V=((40-20)/(70-20))*788
V=(193.6Lts/3.79)
V=51.08
Tanque =
60Gls
Caloria
Para 15min.=0.25h
C= V*(T.C-T.f)/(Tiempo Cal)
C= 193.6Lts*(70-20)/(.25)
C=(38,720Cal/8620Cal)Kw 1Kw=8620Cal
C= 4.49kw/h

T.m=40
T.F=20
T.C=70
A=788Lts