Вы находитесь на странице: 1из 7

TCE.

M4-109-PI-1
TCE-5014A-C-580-601

PRESSURE INDICATORS
DATA SHEET
Sr.No

TAG NO.

SERVICE

LINE

TEMP.C

PRESS
(kg/cm.sq(g))

MAX

RANGE

SECTION D
SHEET 1+1 OF 5

2-VALVE
MANIFOLD

DIAPHRAGM
SEAL

SNUBBER

PROCESS CONNECTION

P&ID

HYDROCHLORIC ACID STORAGE & TRANSFER


1

PG-201

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-002A
[HCL UNLOADING/TRANSFER
PUMP]

PG-202

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-002S
[HCL UNLOADING/TRANSFER
PUMP]

HC-40-PP/FRP-n-5212

65

0-6

NOT
REQUIRED

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" FLANGED,
SS 316 FLANGE WITH
PTFE LINING,SORF PN10 AS
PER DIN 8077/78

TCE.5014A-300-PI-8652

HC-40-PP/FRP-n-5213

65

0-6

NOT
REQUIRED

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" FLANGED,
SS 316 FLANGE WITH
PTFE LINING,SORF PN10 AS
PER DIN 8077/78

TCE.5014A-300-PI-8652

CAUSTIC LYE & SULPHURIC ACID STORAGE & TRANSFER


3

PG-301

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-003A
[CAUSTIC LYE
UNLOADING/TRANSFER PUMP]

CL-50-MS-n-5305

65

0-10

NOT
REQUIRED

REQUIRED
SS316

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8653

PG-302

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-003S
[CAUSTIC LYE
UNLOADING/TRANSFER PUMP]

CL-50-MS-n-5306

65

0-10

NOT
REQUIRED

REQUIRED
SS316

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8653

PG-101

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-001A
[H2S04 UNLOADING
TRANSFER PUMP]

SA-50-CS-n-5319

65

0-10

NOT
REQUIRED

REQUIRED
SS316

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8653

PG-102

PRESSURE GAUGE IN DISCHARGE OF


PUMP 2-P-001A
[H2S04 UNLOADING
TRANSFER PUMP]

SA-40-CS-n-5320

65

0-10

NOT
REQUIRED

REQUIRED
SS316

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8653

SO-40-SA-n-5102

65

0-6

NOT
REQUIRED

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8651

HD-40-CB-n-5104

65

0-6

NOT
REQUIRED

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-300-PI-8651

U.G. STORAGE TANK FARM


7

PG-112

PRESSURE GAUGE IN DISCHARGE OF


PUMP 1-SP-001
[TRANSFER PUMP FOR SOLVENT]

PG-212

PRESSURE GAUGE IN DISCHARGE OF


PUMP 1-SP-002
[TRANSFER PUMP FOR HSD]

COOLING WATER SYSTEM

REV NO: R1
PPD. BY: PRJ
CKD. BY:CSP
DATE: 17.03.2007

PG-401

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-01A

CWS-100-CA-n-1031

35

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-610-PI-1006

10

PG-402

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-01B

CW-100-CA-n-1032

35

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-610-PI-1006

11

PG-403

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-02A

CWS-300-CA-n-1001

32

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-610-PI-1006

1/2" NPT(M)

TCE.5014A-610-PI-1006

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-610-PI-1006

12

PG-404

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-02B

CWS-300-CA-n-1002

32

0-6

REQUIRED

REQUIRED
NOT REQUIRED
SS316

13

PG-405

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-02S

CWS-300-CA-n-1003

32

0-6

REQUIRED

NOT REQUIRED

JOB NO:TCE.5014A

CLIENT:TECHNOVA IMAGING SYSTEMS (P) LTD


PROJECT:OFFSET PRINTING PLATES

TCE.M4-109-PI-1
TCE-5014A-C-580-601

PRESSURE INDICATORS
DATA SHEET
Sr.No

TAG NO.

SERVICE

LINE

TEMP.C

PRESS
(kg/cm.sq(g))

MAX

RANGE

60

SECTION D
SHEET 2+1 OF 5

2-VALVE
MANIFOLD

DIAPHRAGM
SEAL

SNUBBER

PROCESS CONNECTION

P&ID

0-6

NOT
REQUIRED

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-510-PI-1005

REQUIRED
SS316+PTFE

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-510-PI-1005

FURNACE OIL SYSTEM


14
15

PG-821

PRESSURE GAUGE IN DISCHARGE OF PUMP


FOP-01

PG-822

PRESSURE GAUGE IN DISCHARGE OF PUMP


FOP-02

PG-406

PRESSURE GAUGE IN DISCHARGE OF


PUMP 610-P-03A

FO-50-CB-Ih-003-T
FO-50-CB-Ih-007-T

60

0-6

NOT
REQUIRED

CWS-250-CA-n-1084

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

1/2" NPT(M)

TCE.5014A-811-PI-1007

CHILLED WATER CIRCUIT


16
17

PG-407

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-03B

CWS-250-CA-n-1085

40

0-6

REQUIRED

REQUIRED
NOT REQUIRED
SS316

18

PG-408

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-03S

CWS-250-CA-n-1086

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

19

PG-409

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-04A

CWS-250-CA-n-1089

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

PG-410

PRESSURE GAUGE IN DISCHARGE OF PUMP


610-P-04S

REQUIRED

REQUIRED
NOT REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-501

PRESSURE GAUGE AT INLET OF PUMP


811-PCP-02A

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-502

PRESSURE GAUGE AT DISCHARGE OF PUMP


811-PCP-02A

REQUIRED

REQUIRED
NOT REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

23

PI-503

PRESSURE GAUGE AT INLET OF PUMP


811-PCP-02B

CHR-200-CA-IC-1152

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

24

PI-504

PRESSURE GAUGE AT DISCHARGE OF PUMP


811-PCP-02B

CHR-150-CA-IC-1155

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

25

PI-505

CHS-150-CA-IC-1161

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

1/2" NPT(M)

TCE.5014A-811-PI-1007

20
21
22

26

PRESSURE GAUGE AT OUTLET OF CHILLER-4

CHR-200-CA-IC-1151
CHR-150-CA-IC-1154

CHS-150-CA-IC-1162

40
40
40

40

0-6
0-6
0-6

0-6

REQUIRED

PI-507

PRESSURE GAUGE AT INLET OF PUMP


811-PCP-01S

PI-508

PRESSURE GAUGE AT INLET OF PUMP


811-PCP-01A

PI-509

PRESSURE GAUGE AT INLET OF PUMP


811-PCP-01B

30

PI-510

PRESSURE GAUGE AT DISCHARGE OF PUMP


811-PCP-01S

CHWR-200-CA-IC-1108

40

0-6

REQUIRED

REQUIRED
NOT REQUIRED
SS316

31

PI-511

PRESSURE GAUGE AT DISCHARGE OF PUMP


811-PCP-01A

CHWR-200-CA-IC-1107

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

32

PI-512

PRESSURE GAUGE AT DISCHARGE OF PUMP


811-PCP-01B

CHWR-200-CA-IC-1106

40

0-6

REQUIRED

NOT REQUIRED

REQUIRED
SS316

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

27
28
29

33
34
35

REV NO: R1
PPD. BY: PRJ
CKD. BY:CSP
DATE: 17.03.2007

PI-506

PRESSURE GAUGE AT OUTLET OF CHILLER-3

CWS-250-CA-n-1090

PI-513
PI-514
PI-515

PRESSURE GAUGE AT OUTLET OF CHILLER-S


PRESSURE GAUGE AT OUTLET OF CHILLER-2
PRESSURE GAUGE AT OUTLET OF CHILLER-1

CHWR-250-CA-IC-1104
CHWR-250-CA-IC-1103
CHWR-250-CA-IC-1102

CHWS-200-CA-IC-1117
CHWS-200-CA-IC-1116
CHWS-200-CA-IC-1115

40
40
40

40
40
40

0-6
0-6
0-6

0-6
0-6
0-6

JOB NO:TCE.5014A

REQUIRED
REQUIRED

REQUIRED
REQUIRED
REQUIRED

CLIENT:TECHNOVA IMAGING SYSTEMS (P) LTD


PROJECT:OFFSET PRINTING PLATES

TCE.M4-109-PI-1
TCE-5014A-C-580-601

PRESSURE INDICATORS
DATA SHEET
Sr.No

36
37
38
39
40

SERVICE

PI-526

PRESSURE GAUGE AT INLET OF


AHU-1 OFFICE AREA

PI-527

PRESSURE GAUGE AT OUTLET OF


AHU-1 OFFICE AREA

PI-528

PRESSURE GAUGE AT INLET OF


AHU-3 OFFICE AREA

PI-529

PRESSURE GAUGE AT OUTLET OF


AHU-3 OFFICE AREA

PI-530

PRESSURE GAUGE AT INLET OF


AHU-4 OFFICE AREA

LINE

CHS-50-CA-IC-1219
CHR-50-CA-IC-1220
CHS-40-CA-IC-1215
CHR-40-CA-IC-1216
CHS-40-CA-IC-1209

TEMP.C

PRESS
(kg/cm.sq(g))

MAX

RANGE

40

0-6

40
40
40
40

0-6
0-6
0-6
0-6

2-VALVE
MANIFOLD

DIAPHRAGM
SEAL

SNUBBER

PROCESS CONNECTION

P&ID

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

1/2" NPT(M)

TCE.5014A-811-PI-1007

REQUIRED
REQUIRED
REQUIRED
REQUIRED

41

PI-531

PRESSURE GAUGE AT OUTLET OF


AHU-4 OFFICE AREA

CHR-40-CA-IC-1210

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

42

PI-532

PRESSURE GAUGE AT INLET OF


AHU-5 OFFICE AREA

CHS-40-CA-IC-1211

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

43

PI-533

PRESSURE GAUGE AT OUTLET OF


AHU-5 OFFICE AREA

CHR-40-CA-IC-1212

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-534

PRESSURE GAUGE AT INLET OF


AHU-7 OFFICE AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-535

PRESSURE GAUGE AT OUTLET OF


AHU-7OFFICE AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-536

PRESSURE GAUGE AT INLET OF


AHU-8OFFICE AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-537

PRESSURE GAUGE AT OUTLET OF


AHU-8OFFICE AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

48

PI-538

PRESSURE GAUGE AT INLET OF


AHU-13C LAB AREA

CHS-50-CA-IC-1204

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

49

PI-539

PRESSURE GAUGE AT OUTLET OF


AHU-13C LAB AREA

CHR-50-CA-IC-1203

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

50

PI-540

PRESSURE GAUGE AT INLET OF


AHU-13B TERMINAL END AREA

CHS-150-CA-IC-1168

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-541

PRESSURE GAUGE AT OUTLET OF


AHU-13B TERMINAL END AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-542

PRESSURE GAUGE AT INLET OF


AHU-13A TERMINAL END AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-543

PRESSURE GAUGE AT OUTLET OF


AHU-13A TERMINAL END AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-544

PRESSURE GAUGE AT INLET OF


AHU-11B AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

55

PI-545

PRESSURE GAUGE AT OUTLET OF


AHU-11B AREA

CHS-50-CA-IC-1173

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

56

PI-546

PRESSURE GAUGE AT INLET OF


AHU-11A AREA

CHS-50-CA-IC-1174

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

57

PI-547

PRESSURE GAUGE AT OUTLET OF


AHU-11A AREA

CHS-50-CA-IC-1175

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-548

PRESSURE GAUGE AT INLET OF


AHU-12B AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-549

PRESSURE GAUGE AT OUTLET OF


AHU-12B AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-550

PRESSURE GAUGE AT INLET OF


AHU-14 AQUEOUS & CTP COATING

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-551

PRESSURE GAUGE AT OUTLET OF


AHU-14 AQUEOUS & CTP COATING

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-552

PRESSURE GAUGE AT INLET OF


AHU-15 SOLVENT PRE COATING

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

44
45
46
47

51
52
53
54

58
59
60
61
62

REV NO: R1
PPD. BY: PRJ
CKD. BY:CSP
DATE: 17.03.2007

TAG NO.

SECTION D
SHEET 3+1 OF 5

CHS-50-CA-IC-1206
CHR-50-CA-IC-1205
CHS-50-CA-IC-1214
CHR-50-CA-IC-1213

CHS-150-CA-IC-1169
CHS-150-CA-IC-1170
CHR-150-CA-IC-1171
CHS-50-CA-IC-1172

CHS-65-CA-IC-1176
CHS-65-CA-IC-1177
CHS-50-CA-IC-1178
CHS-50-CA-IC-1179
CHS-50-CA-IC-1180

40
40
40
40

40
40
40
40

40
40
40
40
40

0-6
0-6
0-6
0-6

0-6
0-6
0-6
0-6

0-6
0-6
0-6
0-6
0-6

JOB NO:TCE.5014A

REQUIRED
REQUIRED
REQUIRED
REQUIRED

REQUIRED
REQUIRED
REQUIRED
REQUIRED

REQUIRED
REQUIRED
REQUIRED
REQUIRED
REQUIRED

CLIENT:TECHNOVA IMAGING SYSTEMS (P) LTD


PROJECT:OFFSET PRINTING PLATES

TCE.M4-109-PI-1
TCE-5014A-C-580-601

PRESSURE INDICATORS
DATA SHEET
Sr.No

63
64
65
66
67

SERVICE

PI-553

PRESSURE GAUGE AT OUTLET OF


AHU-15 SOLVENT PRE COATING

PI-554

PRESSURE GAUGE AT INLET OF


AHU-10B COATER CABINETAREA

PI-555

PRESSURE GAUGE AT OUTLET OF


AHU-10B COATER CABINETAREA

PI-556

PRESSURE GAUGE AT INLET OF


AHU-10A COATER CABINET

PI-557

PRESSURE GAUGE AT OUTLET OF


AHU-10A COATER CABINET

LINE

CHR-50-CA-IC-1181
CHS-50-CA-IC-1182
CHR-50-CA-IC-1183
CHS-50-CA-IC-1184
CHR-50-CA-IC-1185

TEMP.C

PRESS
(kg/cm.sq(g))

MAX

RANGE

40

0-6

40
40
40
40

0-6
0-6
0-6
0-6

2-VALVE
MANIFOLD

DIAPHRAGM
SEAL

SNUBBER

PROCESS CONNECTION

P&ID

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

1/2" NPT(M)

TCE.5014A-811-PI-1007

REQUIRED
REQUIRED
REQUIRED
REQUIRED

68

PI-558

PRESSURE GAUGE AT INLET OF


AHU-12A GREEN HOUSE-1

CHS-65-CA-IC-1186

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

69

PI-559

PRESSURE GAUGE AT OUTLET OF


AHU-12A GREEN HOUSE-1

CHR-65-CA-IC-1187

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

70

PI-560

PRESSURE GAUGE AT INLET OF


AHU-16 CHE STORAGE

CHS-50-CA-IC-1188

40

0-6

REQUIRED

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-561

PRESSURE GAUGE AT OUTLET OF


AHU-16 CHE STORAGE

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-562

PRESSURE GAUGE AT INLET OF


AHU-18 DIAZO AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

PI-563

PRESSURE GAUGE AT OUTLET OF


AHU-18 DIAZO AREA

NOT REQUIRED

NOT
REQUIRED

1/2" NPT(M)

TCE.5014A-811-PI-1007

71
72
73

REV NO: R1
PPD. BY: PRJ
CKD. BY:CSP
DATE: 17.03.2007

TAG NO.

SECTION D
SHEET 4+1 OF 5

CHR-50-CA-IC-1189
CHS-50-CA-IC-1190
CHR-50-CA-IC-1191

40
40
40

0-6
0-6
0-6

JOB NO:TCE.5014A

REQUIRED
REQUIRED
REQUIRED

CLIENT:TECHNOVA IMAGING SYSTEMS (P) LTD


PROJECT:OFFSET PRINTING PLATES

44

PI-529

PRESSURE GAUGE AT OUTLET


OF HEAT EXCHANGER
GRAINER UNIT

45

PI-530

PRESSURE GAUGE AT OUTLET


OF HEAT EXCHANGER
ANODIZING PROCESS

46

PI-531

PRESSURE GAUGE AT OUTLET


OF COATING PROCESS

47

PI-532

PRESSURE GAUGE AT OUTLET


OF CAMEL BACK OVEN-1

48

PI-533

PRESSURE GAUGE AT OUTLET


OF CAMEL BACK OVEN-2

49

PI-534

PRESSURE GAUGE AT INLET


OF HEAT EXCHANGER
GRAINER UNIT

50

PI-535

PRESSURE GAUGE AT INLET


OF HEAT EXCHANGER
ANODIZING PROCESS

51

PI-536

PRESSURE GAUGE AT INLET


OF COATING PROCESS

52

PI-537

PRESSURE GAUGE AT INLET


OF CAMEL BACK OVEN-1

53

PI-538

PRESSURE GAUGE AT INLET


OF CAMEL BACK OVEN-2

CHWR-250-CA-IC1126

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWR-250-CA-IC1127

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWR-50-CA-IC1128

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWR-50-CA-IC1129

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWR-50-CA-IC1130

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWS-250-CA-IC1120

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWS-250-CA-IC1121

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWS-50-CA-IC1122

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWS-50-CA-IC1124

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

CHWS-50-CA-IC1125

7-12

0-6

REQUIRED

NOT
REQUIRED

NOT
REQUIRED

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007

TCE.5014A-811-PI-1007