OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

DHAKAELECTRICSUPPLYCOMPANYLIMITED(DESCO)
inAssociationwithInstituteofArchitectsBangladesh

OPENARCHITECTURALDESIGNCOMPETITION
fortheDesignofDESCOHeadOfficeBuildingatPlotno49/A,DhakaMymensinghRoad,Nikunja(North),Khilkhet,Dhaka.

COMPETITIONBRIEF
Twostaged,National, Anonymous architecturaldesign competition: Jointly OrganizedbyInstitute of ArchitectsBangladesh(IAB) &DhakaElectricSupply
CompanyLimited(DESCO).

ARCHITECTURALCONTRIBUTION

Competitions are a unique way to provide opportunity to the architects for experimentation, brain storming, thought provocation and creativity. It is a
motivationforarchitectstosearchanswersfortheirquestions,builduptheirunderstandingaboutsociety,humanbeing,context,economyetc.,andthus
reflectingtheirthoughtsintophysicalenvironmentthrougharchitecturaldepiction.Entrantsarefreetoexploreasfarastheyarewillingtopushthebar
setoutforthecompetition,butnotbreakingthem,toavoiddisqualification.

Page.1


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

ABOUTDHAKAELECTRICSUPPLYCOMPANYLIMITED(DESCO)

HISTORY

In the prevailing socioeconomic and political environment it is a great challenge in earning customer confidence for a public sector utility company In
Bangladesh.Butdespiteallrealitiesandconfrontingallchallenges,DhakaElectricitySupplyCompanyLtd(DESCO)iscommittedtoachievethedistinctionof
theleadingmostcompanyinthecontextofearningcustomersconfidence.

TheemergenceofelectricityuseinourpartoftheworldwhereBangladeshissituateddatesback140years.Actuallyelectricitycamehereonlytwoyears
aftertheusestartedinerstwhileKolkata.ABritishcompanyon24June1879firstsetthemillstoneofelectricityuseinKolkata.Graduallyafterwardslimited
scale use of electricity started in different parts of undivided India. But the first formal use of electricity started from the first thermal power plant by
CalcuttaElectricitySupplyCorporation(CESC)inApril1899underthepatronageofLordCurzon.

NawabofDhakaintroducedelectricityinBangladeshin1901.OnlyAhsanManzilusedtoenjoytheprivilegeofusingelectricityinitially.Electricityusefor
generalcitizensstartedin1930.AcompanynamedDEVCOwascreatedforpowerdistributioninDhaka.Theyusedtogeneratepowerintheirownplant
and supply. It continued till 1947. Pakistan government took it over in 1957. In 1947, other than Dhaka 17 other districts were partially under power
generation and distribution coverage. After creation of Water and Power Development Board in 1959 power generation and distribution came under
exclusivegovernmentcontrol.

AfterindependenceofBangladesh,WAPDAwasdividedintotwoparts.Theresponsibilityofpowergenerationanddistributionwasvestedonthepower
wing of WAPDA. From 1972 till 1991, BPDB was exclusively responsible for power distribution in the entire country. After the creation of Rural
ElectrificationBoard(REB)in1977thetaskofsupplyingpowerinruralareaswasgraduallyhandedovertoREB.NowREBisdischargingthisresponsibility
through72PollyBidyutSamity(PBS).

From19711991thePowerSectorwasdependentonloansandassistanceofdevelopmentpartnersanddonoragencies.Butchangingparadigminglobal
scenario generated encouragement among investment communities for investment in Bangladesh power sector. But at the same time donor agencies
offeredfinancialassistanceattachingvariouscovenantsforreformsandrestructuring.Onthebackdropofabove,DhakaElectricSupplyAuthority(DESA)
washandedovertheresponsibilityfromBPDBforsupplyingpowerinDhakaMetropolisandadjacentareas(Narsingdi,Gazipur,Narayanganj,Munshiganj
and Manikganj). DESA was created with three major objectives. These were: Reducing staggering system loss, increase revenue collection and ensuring
bettercustomerservices.DESAwascreatedthroughaPresidentialOrderin1990andstartedoperationin1991.

Page.2


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

After5yearsofDESA,anewpublicsectorcompanynamedDhakaElectricSupplyCompanyLtd(DESCO)wascreatedin1996underCompanyAct1994,
withasmallareaMirpurwashandedovertoDESCOfromDESA.

DESCOstartedoperationaftertwoyearsofcreationwithonly90MWpowerdistributionand71,161customers.Nowin2015,DESCOsupplieselectricityto
almost7,05,000customers.Startingwithasystemlossofabout47%ithasmanagedtobringitdownto8.37%.Itisnowafinanciallyviable,profitearning
PublicUtilityCompany.

DESCO is working to meet the future demand, better customer service expectation of the customer and modern power distribution system by 2030
expecting2.8millionofconsumers.

VISION&MISSION

Vision

Tobeanenablerofeconomicdevelopmentandsocialprogressbyprovidingsafe,reliableandsustainableelectricity.

Mission

Bringing comfort to customers, supporting business and commerce and building strong communities. Achieving and maintaining the highest degree of
efficiency,reliabilityandresponsivenessforvarietyofcustomers.

CORPORATEPHILOSOPHY
DESCOwillachievetheirvisionthroughtheircorecorporateprinciple.
Safety:Placingthesafetyofourcommunities,customersandemployeesfirst;
CustomerFocus:Providingsuperiorservicetohelpcustomersmoreeffectivelymanagetheiruseofelectricity;
OperationalExcellence:Incorporatingcontinuousimprovementtodeliversafeanddependableelectricityataffordableprices;
PerformanceDrivenCulture:Fosteringastrongvaluesandperformancebasedculturedesignedtoattract,developandretainbesttalents.

Page.3


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

ABOUTCOMPETITION
CRITERIA

Thearchitecturaldesigncompetitionwillbeanopenprocedureintwostages,whichwillhighlightoutstanding
intermsofidea,sustainableandmostinnovativegreenBuildingsolution.
ProjectCost:ApproximatelyTk.100crore.

FirstStage:
ThefirststageconsistsinfindinganadequateapproachtotheSpecificationsandprogramofthecompetition.
ThisstagemustenabletheCommissioningOrganizationtoassess,howtheprojectwillbeassimilatedonsite,its
architecturalquality,theextenttowhichtheprojectmeetstheobjectivesoftheprogram,howtheprojectdeals
with the issue of functionality and access, cost effective use of space, energy efficiency, local resources and
sustainabilitywithuniversal/handicappedaccessfacilities.
Sixentrants(Maximum)willbeinvitedtoparticipateinthesecondstage.

SecondStage:
ThesecondstagemustallowtheselectedcandidatestodeveloptheirprojectsonthebasisoftheJuryreport
andanindividualassessment.
Participantswillsubmitapreliminaryestimatedcostoftheproject.

SITE

Plot49/A,Nikunja(North),Khilkhet,Dhaka
Sizeoftheland:40.25katha(28,980sq.ft.)
North&South:161ft.;East&West:180ft.
HeightLimit:146ft.asperCivilAviationclearance.

PRIZES

FirstStage:
NoprizesshallbeawardedintheFirstStage,buteachofthecompetitors(maximumsix)selectedfortheSecond
StageshallreceiveanhonorariumofTk.2,50,000.00(TakaTwoLacFiftyThousandOnly).
SecondStage:
1stprize:Certificate+Tk.5,00,000.00(TakaFiveLacOnly)
2ndprize:Certificate+ACrestfromDESCO
3rdprize:Certificate+ACrestfromDESCO

Page.4


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

JURORS

1.Ar.NahasAhmedKhalil
2.Ar.ABMMahbubulMalik
3.Ar.MohammadFoyezUllah
4.Mr.Md.AbdullahAlMasudChowdhury
5.Engr.Md.RabiulHasnat

ELIGIBILITY

1.TheeligibilityoftheArchitect(TeamLeader)willbeaccordingtoguidelinesoftheImaratNirmanBidhimala,
2008.
2.Everyparticipantshouldbeanarchitectrepresentinganarchitecturalconsultancyfirm.

REGISTRATION

1.SUBMITRegistrationFeetoIABofficeandobtainaRegistrationNumberfromDec26,2015toJan10,2016.
RegistrationfeeTK3,000/(nonrefundable)
2.DownloadRegistrationFormfromwww.iab.com.bd
3.FilluptheRegistrationFormandmailtodesco.iabcompetition@iab.com.bd
4.Oneregisteredparticipantcansubmitonlyoneproposal.

QUERIES

1.DownloadQueriesFormfromwww.iab.com.bd
2.Fillupandmailtodesco.iabcompetition@iab.com.bd

TIMELINE

FirstStage:
AnnouncementinNewspaper
CORRIGENDUM(Announcement)
Registrationopens
ReceivingQueries
ReplytoQueriesbyemail
DesignSubmission
JuryProceedings,Announcement
ofResultsandExhibitionopening
SecondStage:
LettertoShortListedFirms
HandingOveroftheJury'sFirstStageReport
DesignSubmission
JuryProceedingsandAnnouncementofResult
WillbeInformedlater.
TheremaybeaPublicationwithalltheEntries.

SUBMISSIONVENUE
PUBLICATION

Dec14,2015
Dec24,2015
Dec26,2015Jan10,2016
Jan07,2016 Jan13,2016
Jan16,2016
Mar10,2016
Mar12,2016Mar16,2016
Mar14,2016
Mar18,2016
May07,2016
May09,,2016

Page.5


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

SUBMISSIONREQUIREMENTCHECKLISTFORFIRSTSTAGE

Items
DECLARATIONFORM

SPACEPROGRAMCHECKLIST Oneno.

DRAWINGSHEETS

MODEL

REPORT

CD

Quantity/Specifications
Oneno.

3Sheets,Landscape,A1size
scale=1:200
ShowingNorthUpWard
Oneno.
Base:24x24Size
scale_1:200
showingNorthUpward
4to6pages,Portrait,A4size
FontArial10pt
Oneno.containing
1.softcopyofconceptualdrawingand3D
image
2.photosofmodel
3.report

Remarks

DownloadtheDECLARATIONFORMfromWebsite
www.iab.com.bd,fillup,print&Signbeforesubmit
DownloadtheWhiteEnvelop,TypeReg.No.(xxxxx)&print.
SubmittheDECLARATIONFORMonSubmissiondayinThe
WhiteEnvelope.
DownloadtheCHARTfromWebsite,fillup&print
PUTyourRegistrationNo.atthecenterofthebackofthepage
beforesubmit.
Page1:forConcept
Page2:forDrawingsPlans,Elevations,Sections
Page3:for3Dimages,Perspective

SubmissionRequirementCheckListforSecondStagewillbeinformedlatter.

Notes:
A25.4mmx25.4mmblankboxtobeput,25.4mmoffsetfromtheUpperRightcorneroftheDrawingsheets,Modeltobeplaced.
TheNorthsigntobeputontheLowerRightcorner.TheNorthtobedirectedtowardsUpwardinalldrawings&model.
Page.6


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

DISQUALIFICATION
Anentryorentrantwillbedisqualifiedif
TheydonotcomplywiththeEligibilityRequirements.
TheydonotcomplywiththeEntryRequirements.
Theentryisreceivedafterthelodgmentdeadline.
TheentrantimproperlyattemptstoinfluencethedecisionoftheJury.
The entrant has communicated directly with any member of the Jury, employee involved in the competition, or any coordinator or advisors
engagedbytheIAB/DESCOforthePurposesofthecompetition.
Anyname,signorsymbolondrawings,modeloranysubmittalthathelpstotraceTheparticipantwilldisqualifytheentry.
AnydeviationoftheNotesabovemaycausedisqualification.

LEGALANDREGULATORYPRINCIPLES
Entry in this competition implies agreement by the Organizer (IAB and DESCO), the Jury and the candidates to abide by the terms of the competition
regulations,specificationsandprogram,andtherepliesgiventoEntrants'queries.
SubmissionofanentryconstitutesacceptanceofthedecisionsoftheJuryandthedecisionofDESCO,whichshallbefinal.
TheCommissioningOrganizationundertakestofollowanimpartialprocedurefortheselectionofcandidates.Noappealshallbeadmitted.
Byparticipatinginthecompetition,candidatesconfirmtheiracceptanceoftheseregulations,specificationsandprogram,andaffirmthattheyare
acquaintedwithandwillstrictlyabidebytheTimetableforthesuccessivestages.

PROPRIETY
Competitors(oranyrepresentativeofacompetitor)mustnotatanytimebeforetheJurymakesfinalannouncementofawinner,contactorinterviewor
attempttointerviewortodiscussortoattempttodiscusswithJurymembers,employees,Competitioncoordinatorandauthorizedrepresentatives,any
matteraboutthecompetitionoranyotherentrantSubmittedinresponsetoThiscompetition.Thejuryreservestherighttorejectanyentrylodgedbya
competitorwhichcontravenesthiscondition.

COPYRIGHT
EntrantsretaincopyrighttotheirentriesbutwillgiveIABandDESCOaperpetual,royaltyfreelicensetousetheirentriesforthefollowing:
Informing and consulting the community through an exhibition. Documenting the competitive process for internal reporting, public notification; and
InclusiononIABwebsiteorinanypublicationpreparedbytheIABonthecompetitionProcessandoutcomes.
Page.7


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

PROGRAM
PleaseDOWNLOADtheOrganogramandFunctionalSpaceRequirementChecklistfromwww.iab.com.bd
GeneralFacilitiesandRequirements:
OverallCapacityandFloorareaoftheComplex:ComplexshallbeasperRAJUKapprovedLayoutplanwithwellairventilatedsystemandthereshallbe
capacityofofficearrangementsofheadofficeofficersandstaffsofDESCOtocarryouttheirofficialactivities.Allfacilityistodevelopedwithin;

MaximumcoverageoflandforthebuildingasperRAJUKruleandcosteffectiveuseofspace.
Carparkingandutilityfacilityin03nos.Basement.
Lobby:Centrallocationforbuildingdirectory,schedules,andgeneralinformation.
Bank,ATM,VendingStation,Waitingroom,Reception,OfficeRoomforbuildingmaintenance,ConvenienceStore,Kiosk,orVendingMachines
inthegroundfloor

DESCOOFFICE
ManagingDirectorsOffice

ManagingDirectorOfficewithmeetingarrangementsfor20persons,spaceforrestingandprayer,washroom/toiletfacilitiesinafloor.

ExecutiveDirectorsOffice

OfficeoftheExecutiveDirectors(AdministrationandHR)
OfficeoftheExecutiveDirectors(Procurement)
OfficeoftheExecutiveDirectors(Operation)
OfficeoftheExecutiveDirectors(Engineering)
OfficeoftheExecutiveDirectors(Finance)

RoomsforDirectorswithmeetingarrangementfor12persons,spaceforrestingandprayer,washroom/toiletfacilitiesinafloor.
StaffOfficerofManagingDirectorandExecutiveDirectorsroom.
MeetingRoom:acommonmeetingroomofsittingarrangementsof15Personsateachdirectorate
Waitingspace:visitorsroomintheManagingDirectorsandExecutiveDirectorsfloors

Page.8


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

Officeforseniorofficers(ChiefEngineers/GeneralManagers):
OfficeroomsforChiefEngineers/GeneralManagerswitharrangementsforrest,prayerandtoiletfacilities.

Officeforseniorofficials:
SuperintendingEngineers/DeputyGeneralManagersofficewithtoiletfacilities
ExecutiveEngineers/Managersofficewithtoiletfacilities
SubdivisionalEngineers/DeputyManagersoffice.
AssistantEngineer/AssistantManager.
Officeforothersofficialsshallbeinopenspacewithcubicalsystemandcommontoiletfacilities.
OpenWorkingspaceforsupportingstaffs:inopenspaceadjacenttoconcernofficer,andwithcommontoiletfacilities.
Waitingspace:visitorsroomintheManagingDirectorsandExecutiveDirectorsfloors
GeneralStorage:Foritemssuchasstationery,equipment,andinstructionalmaterials.

ManagingDirector/ExecutiveDirector/SeniorofficersroomsizeshallbearrangedandmaintainonthebasisoftheRankandLevelaccordingly.

DESCObuildingshouldincorporateanumberofspacetypestomeettheneedsofstaffandvisitors.Itmustbeabletoaccommodatethespecificspaceand
equipmentneedsoftheDESCO.Specialattentionshouldbemadetotheentryspaces,conferenceroomsandotherareaswithpublicaccess.

DESCOBOARDANDCHAIRMANSOFFICE:

BoardChairmansofficewithresting,prayerandwashroom/toiletfacilities.
RoomforBoardDirectors:Acommonroom/LoungeshallbeprovidedforthemembersoftheBoardwithIndividualcabinetfacilityandwash
room/toiletfacilities.
BoardMeetingRoom:arrangementsof50personsintheBoardRoomwithOtherfacilitiesincludespaceforsupportingstaff,toiletfacilities,
spacefordocumentpreservationandothers.
OfficeoftheCompanySecretary(GeneralManagerwitharrangementsforrestingandprayer,toiletfacilities.
Officeforotherofficials:providedinopenspacecubicalsystemandcommontoiletfacilities.
Sittingarrangementsforsupportingstaffsshallbeprovidedinopenspaceadjacenttoconcernofficerwithcommontoiletfacilities.
GeneralStorage:Foritemssuchasstationery,equipment,andinstructionalmaterials.
Page.9


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

Seniorofficer's/othersofficialroomssizeandfacilitiesshallbearrangedandmaintainonthebasisoftheRankandlevelaccordingly.

Conference/MultiPurpose/SeminarHall:

MultiPurposeHall:AMultipurposeHallofcapacityaround1,000personswithperfectionandpantryspaceandbackstagefacilities.shall
SeminarRoom:SeminarRoomshallbeofcapacityupto250peoplesperfectionandpantryspace.Thereshallberearrangementsfacilitiesof
thesizeoftheroom.

GuestHouse:
Buildingshallhaveaccommodationfor04VIPGuestsuiteswithallfacilities.

OthersFacilities:

PrayerRoom:Thereshallbeseparateprayerroomformaleandfemale(male175,female25)personsatatime.
CommonToilet:Thereshallbesufficientcommontoilet/washfacilitiesateachfloorindifferentside/cornerswithseparateMaleandFemale
toiletoptions.
HealthClub&GYM:GYMfacilities.IndoorHealthZone,MedicalCentreandrelevantfacilitiespreferablyinthesamefloor.
Child/BabyCareCentre:Ababycareroomandfacilityforthefemaleemployees(1015babies)
Cafeteria/DiningHall:Thereshallbeonecafeteria/DinningforOfficerswithmaximumcapacityof50personsandaVIPCuisine.Onecafeteria
forStaffswithmaximumcapacityof70persons.KitchenandServicesroomshallbeprovidedfortheCafeterias.
KitchenandServicesRoom:KitchenandServicesspaceshallbefortheinthedifferentfloors.
Library and Archive Facilities: There shall be common archive and library in the same floor of the building, there shall be arrangements for
documentpreservationforeachdivision/department.
AccessofCorridor:Congestedcorridorsarenotencouraged.Sufficientlightingandventilationsystemsshallbeincorporatedforthecorridor.
EntryandExitoptionsforvehicles:Thereshallbeseparateentryandexitoptionsforvehiclesandpedestrians.
Generator:StandbyGeneratorshallbeprovidedforPump,Lift,Airconditions,safety security system and some emergency lights at
corridors.Othergenerallightsshallbeoperatedbysolarpowersysteminthedaytime.
Page.10


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

CommunicationSystem:spaceandprovisionsforTelephone,PABX,Internet,andOpticalFibercableconnectivityforthecomplex.
Safety and Security: Sufficient securityarrangementsshall be provided for thecomplex. Onesecurity and firecontrolroom,(the firefighting
system,accesscontrolandothers.Closedcircuitcameraforbothdaynightsystemsshallbeincorporate).
ProvisionforSurfaceParkingAreas.
Airconditioning:SpaceforCentralAirconditioning system.TheCompressor,Chiller,Pumps,Energymanagement system(substation,switch
gear,PFIplant,metering,Energycontrollingsystemetc.)Andcoolingtower.
Basement:Thereshallbe03(three)nos.ofBasementatthebuilding.
SewerageTreatmentSystem:ModernSewerageTreatmentSystemshallbeprovidedforthecomplex.

ElectricalSubstationandGeneratorroommaybeplacedatbasement01andcarParkingshallbeplacedatothertwobasements.Thereshallbedrivers
waitingroominthebasement.

SCADAandDataCenter:

SupervisoryControlDataAcquisition(SCADA):Around8000(eightthousandsft)offloorspaceshouldbeprovidedtoaccommodatetheSCADA
systemandcontrolroomwithappropriatefloorheight.
Data Center: Around 4000(Four thousand sft) of floor space at suitable floor should be provided to accommodate the Data Center with
appropriatefloorheight.
Separateaccessfortherentedoutoffices:SeparateentryandexitfacilitiesshouldbeprovidedfortheotherRentedoutofficeareas.
WallDigitalDisplay:AbigDigitaldisplayscreenontheouterwallshouldbeprovidedatanysuitableposition.

OperationandMaintenanceSpaces:

ServerroomandComputer/InformationTechnology(IT)Closets.
MaintenanceClosets.
GeneralStorage:Foritemssuchasstationery,equipment,andinstructionalmaterials.

RentableOfficeSpace:

DESCOwillrentouttheirextraSpace
Maintaining all the environmental and sustainable consideration, natural lighting, natural ventilation, spatial relationship of Indoor and Out
DoorSpacewouldbeappreciable.
Page.11


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

SITE,LANDAREA&FAR

Address:Plotno49/A,DhakaMymensinghRoad,Nikunja(North),Khilkhet,Dhaka.DhakaMymensinghroadontheEastside.
Sizeoftheland:40.25katha(28,980sq.ft.)
North&South:161ft.;East&West:180ft.
HeightLimit:146ft.asperCivilAviationclearance.

Page.12


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

FARCalculation
TotalLandarea
:
Existingroadwidth

:
ApplicableFAR

:
Maximumgroundcoverage :
MaximumBuildingHeight:
MaximumBuiltArea:

40.25katha(28,980sq.ft.)
300ft(100M)
NR
50%ofthetotalland
146

Page.13


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

TERMS&CONDITIONS

AFTERTHEFINALRESULT
SELECTIONOFARCHITECT&FIRM
1. TheArchitecturalFirm(consistsofArchitect/Architects)winningtheFirstPrizeshallbeformallyappointedbyDESCOinaccordancewiththeAgreement
along with Conditions of Engagements of IAB unless and the fees for Architectural, Structural, Electrical & Mechanical and Plumbing Consultancy
servicesshallbe5.30%(FivepointThreezeropercent)ofthetotalconstructioncost(ThetotalfeeswillbeconsideredincludingVATandAIT),unless
thereisanyvalidreasontodeclinesuchappointmentundertheIABCodeofEthicsandProfessionalConductortheIABCompetitionRegulations.In
suchcase,theArchitect/ArchitecturalFirmofthe2ndbestawardeddesignshallbeappointedasthearchitectandthearchitect,ifrequired,shallhave
tomakeanyreasonablemodificationstohis/herdesigninaccordancewiththerecommendationsofthejury.Ifthesameprocessfailsforthe2ndbest
design,thenthe3rdbestawardeddesignshallbeappointedasthearchitect,andshallhavetomakemodificationsinthesameway,ifrequired.
2. DESCOcanappointthefirstprizewinnerforFulltimesupervisionoftheprojectwithafeeupto2.2%(TwopointTwopercent)(Thetotalfeeswillbe
consideredincludingVATandAIT)ofthetotalprojectcostorreservestherighttoappointanyotherwinner(shortlistedforsecondstage)ratherthan
thefirstprizewinnerforthisjobwiththesamefee.
3. DESCOmayappointthefirstprizewinnerfortheirofficeInteriorDesignoftheprojectorreservestherighttoappointanyotherwinner(shortlistedfor
secondstage)ratherthanthefirstprizewinnerforthisjob.Feeforthisjobwillbefixedupontheagreementofbothparties.
4. ThefirstprizewinnersprizemoneyshallbeconsideredasAdvancePaymenttothecommissionedarchitect(s)andshallbeadjustedwiththewinning
Architectstotalfee.
5. Ifthejuryisnotsatisfiedabouttheabilityofthe1stprizewinningarchitecttocarryouttheproject,theyshall,inconsultationwiththewinner,advise
DESCOthatanestablishedArchitect/Consultantacceptabletothepromoterbeappointedincollaborationwiththe1stprizewinnerincarryingoutthe
work.
6. AnydisputeonthetermsandconditionsofappointmentpriortosigningoftheAgreementshallbesettledbyapersonnominatedbyIAB,ifnecessary,
asarbitratorbetweenDESCOandthewinner.ThedecisionoftheArbitratorshallbefinalandbindingonDESCO&theWinner.
7. If,foranyunavoidablereason,DESCOwantstocancelthecompetitionaftertheentriesarereceived,theentrieswillbeevaluated&theprizeswillbe
awarded.Insuchcase,thecopyrightandauthorshipofthedesignswillremainwiththerespectivearchitectsandAMIshallreturnallthesubmitted
designstothem.NoneofthesubmitteddesignscanbeexecutedbyAMIoranyotherarchitectappointedbyDESCO.

Page.14


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

EVALUATIONCRITERIA

A.

Criteria

Achievementintermsoffreshnessofideas&architectural
thinking

B.

Sustainability

1.EnergyEfficiency:

Achievements

Remarks

2.EcologicalIssues:

3.SpatialIssues:

C.

Functional&Aestheticissues

Page.15


OpenArchitecturalDesignCompetition fortheDesignofDESCOHeadOfficeBuilding

CALENDAR

Su M T
December,2015
January,2016
February,2016
March,2016
April,2016
May,2016
June,2016
July,2016
RegistrationOpen
ReceivinigQuery

W Th F
1

2
1

3
2

4
3

4
1

5
2

Sa Su M T
4
1
5
4
1
6
3
1

5
2
6
5
2
7
4
2

6
3
7
6
3
8
5
3

W Th F

Sa Su M T

7 8 9 10 11 12 13
4 5 6 7 8 9 10
8 9 10 11 12 13 14
7 8 9 10 11 12 13
4 5 6 7 8 9 10
9 10 11 12 13 14 15
6 7 8 9 10 11 12
4 5 6 7 8 9 10

AnswertoQuery
DesignSubmission

14
11
15
14
11
16
13
11

W Th F
15
12
16
15
12
17
14
12

16
13
17
16
13
18
15
13

17
14
18
17
14
19
16
14

Sa Su M T
18
15
19
18
15
20
17
15

19
16
20
19
16
21
18
16

20
17
21
20
17
22
19
17

21
18
22
21
18
23
20
18

W Th F
22
19
23
22
19
24
21
19

23
20
24
23
20
25
22
20

24
21
25
24
21
26
23
21

Sa Su M T
25
22
26
25
22
27
24
22

26
23
27
26
23
28
25
23

27
24
28
27
24
29
26
24

28
25
29
28
25
30
27
25

W Th F

Sa Su

29 30 31
26 27 28 29 30 31
29
26
31
28
26

30 31
27 28 29 30
29 30
27 28 29 30 31

JuryResultExhibition

Page.16

Вам также может понравиться