M7780-000020

LB-CB switch
Operating instructions
(BANV LB-CB OMK)
Valid M3926-384011 TFNAPP MT
Phone cradle and LB-CB switch locking
are mounted in the control box (Figure 1).
LB-CB switch should be set before the line is connected to
contact screws La and Lb.
Connection to local battery lines (LB)
1. Make sure the switch is in position LB.
If the switch is in the CB position Do the following:

a. Pull the catch straight out and hold it extended.


b. Push the switch and turn it to position LB.
c. Leave the latch then let it go back to lock pawl
bolt.
2. Call and end signal should be made with generator handle.
Connection to central battery network (CB)
1. Ensure that the switch is in position CB.
If the switch is in position LB Do the following:

a. Pull the catch straight out and hold it extended.


b. Turn the switch to CB. The switch moves
then to its upper position.
c. Leave the latch then let it go back to lock pawl
bolt.

Call and answer by lifting off handset and pushing the switch to its lower
position, where it is automatically locked.
3. When the call is ended replace handset on cradle, and the switch should
be released.
The generator should not be used when the telephone set is
connected to the CB network.
In automated CB networks (AT) networks connected dial on
usual manner. Calls are made as above.
Place the handset in the cradle when the call is not in progress!
Battery location in case shown in Figure 2.
Batteries will always be needed, remove for batteries for storage to
reduce risk of leaks.