Вы находитесь на странице: 1из 5

Shear

Spandrel

PROBLEM 2.27
Beam
Design a one-way slab to carry a service live load of 4000 Pa. The slab has a length of
f ' c =21 MPa
f y =415 MPa
4m with both ends continuous. Assume
and
for main
bars and

f y =276 MPa

for temperature bars. Steel cover is 20 mm. Unit weight of

3
concrete is 23.5 kN/ m .

SOLUTION
Consider 1 m strip, b = 1000 mm
w L =4 kpa x 1 m=4 kN /m
Uniform live load,

Minimum slab thickness from Table 2.1:


hmin =

L
4000
h min=
28
28

hmin =143 mm(use 150 mm)


Weight of beam (DL):
w D = conc x b x h w D =23.5 (1 ) (0.15)
w D =3.525 kPa
w u=1.4 w D + 1.4 w L w u=1.4 ( 3.525 ) +1.7( 4)
w u=11.735 kN /m
Maximum factored moment, Section 408.4 (See Page 29)
LL < 3 DL

Moment

Effective depth, d = 1.50 20 1/2 (12)


Effective depth, d = 124 mm
At midspan:

M u=

w u Ln
11.735(4)2
M u=
16
16
2

M u=11.735 kN m

124

M u= Rn bd 2 11.735 x 106=0.90 R n(1000)


Rn=0.848 MPa

=0.0021

min =

Use

0.85 f ' c
2 Rn
0.85(21)
2( 0.848)
1 1
=
1 1
fy
0.85 f ' c
415
0.85(21)

1.4
=0.00337> 0.0021
fy

= min =0.00337

A s =bd A s=0.00337 ( 1000 ) (124)


2

A s =418 mm

Spacing, s =

(12)2
A sb
4
x 1000 s=
x 1000
As
418

s=271 say 270 mm

Maximum spacing required by the Code:


a) 3 h=3 ( 150 ) =450 mm
b) 450 mm

Thus, use 12 mm bottom bars at 270 mm o.c. at midspan


At support:
w u Ln2
11.735(4)2
M u=
M u=
10
10
M u=18.776 kN m
M u= Rn bd 2 18.776 x 10 6=0.90 Rn ( 1000 ) (124)2
Rn=1.357 MPa

0.85 f ' c
12 Rn
0.85(21)
2(1.357)
1
=
1 1
fy
0.85 f ' c
415
0.85( 21)

max =0.0034> min

max =0.75

0.85 f ' c 1 600


0.85 ( 21 )( 0.85 ) 600
max =0.75
f y (600+ f y )
415(600+415)

max =0.0162>0.0034
Use

=0.034

A s =bd

A s =0.0034 ( 1000 ) (124)


2

A s =422 mm

Spacing,

(12)2
A sb
4
s=
x 1000 s=
x 1000
As
422

Spacing=268 say 265 mm

Thus, use 12 mm top bars @ 265 mm o.c. at support


Temperature bars (10 mm): (

t =0.002

A t =0.002 bh A t=0.002 ( 1000 ) (150)


A t =300 mm

10

Spacing, s =

A sb
x 1000 s=
As
s=261 say 260 mm
Maximum spacing required by the Code:
a) 5 h=5 ( 150 ) =750 mm
b) 450 mm
Thus, use 10 mm temperature bars @ 260 mm o.c.
10 mm temperature
bars @ 260 mm o.c.

150 mm

12 mm main bars
@ 265 mm o.c.
L/4

L/2

L/4