Вы находитесь на странице: 1из 8

Multi Unit Restoration Screw retained restoration

System overview
1. Straight multi unit - abutment in connection with implants can be mounted on six different heights:
EMU-00...

Cat No. :
2 mm

1 mm

3 mm

4 mm

5 mm

SMU-4023
Screw for Multi
Unit Sleeve

6 mm

2. 18 and 30 Angled Multi unit abutments available in three different heights: H00, H01, H02.
AMU-18...-M

AMU-30...-M

18

18

18

30

30

30

H00

H01

H02

H00

H01

H02

3. Angular Adapter can be mounted on three different angles:

Multi unit cover - Can be mounted on four different heights:

Recommended in cases that soft tissue thiknes is more than 4mm.

18

30

2 mm

3 mm

4 mm

5 mm

Accessories

PSU-0032
Plastic sleeve

TSU-1250
Titanium sleeve

TMU-0532
Titanium short
sleeve

TMU-1200
Open tray transfer

TMU-8005
Close tray transfer

WQP-0011
Plastic for close
tray transfer

HCC-4550
Healing cap

AMU-1201
Analog

SSU-1648
3D scanning device

Two piece structure

One piece structure

Standard prosthetic
screw size (1\72)

Wide Angle Connection


for high stability

Smooth Shape
for max gingival
restoration

The strucrute
is straightened
to the implant

Angle corection
in the base of the
implant for low
forces

Optimal emerging
profile

4. Angle and height clip gauge - use the gauge kit for angle and height selsction.

5 mm
4 mm
3 mm
2 mm

30

5 mm
4 mm
3 mm
2 mm

18

5 mm
4 mm
3 mm
2 mm

6 mm
5 mm
4 mm
3 mm
2 mm
1 mm

Clip Attachment

By using the angle gauges it gives you an option to pre plan


the abutment use in order to achive maximum paralellism.

5. Multi unit connection - use the holder to place the base connection into the implant.

Cat No. : AMU.....

18

30

Multi unit abutments attached to the implant

6. Multi unit base connection - use the holder to place the base connection into the implant.

Cat No. : EMU...10

18

30

7. Match the Multi unit cover abutment height 2-5 mm as required.

Cat No. : MUC...

2 mm

3 mm

4 mm

5 mm

8. Close tray impression coping - with plastic cap.

Cat No. : TMU-8005

Asembley

Snap clip for positioning assurance.

Use close tray impression coping.

9. Open tray impression coping - connect the transfer on the abutment.


Inject impression material and seat the impression tray

Cat No. : TMU...1200

Open tray

Inject impression material and seat the impression tray.


Send the impration tray to the laboratory.

10. In cases of two stage surgery is indicated:


Healing procedure - connect the temporary restoration healing cap.

Cat No. : HCC-4550

Healing cap

The original denture can be used on top of the healing caps during
the production of the temporary denture.

11. Connection of the temporary prosthetic restoration - verify tightening of 15 Ncm.

Note: The screw geometry was carefully designed and optimized to


allow safe tightening and long service. Special attention must be paid
while tightening the screw. Make sure to use original Surcam hex key
with edges that do not show wear. It is recommended to purchase
additional screws.

Cat No. :
SMU-4023
Screw for Multi
Unit Sleeve

Cat No. : TSU-1250

Titanium sleeve

12. The sleeves height need to be trimmed to the desired height.