Вы находитесь на странице: 1из 9
cept City OF Los ANGELES scpanmenror coemateed pee See MARSHAL BROWN — PRESENT ANDREW A. ADELMAN, PE. VAN AMBATIELOS a ce PRESENT RAYMOND CHAN VICTOR H. CUEVAS ANTONIOR. VI-LARAIGOSA Beernuseenees HELENA JUBANY MAYOR = ELENORE A, WILLIAMS ITW Ramsev/Red Head RESEARCH REPORT: RR 2748 2171 Executive Drive, Suite 100 (CSI#03150) Addision, IL 60101 BASED UPON ICBO ES EVALUATION REFORT NO, ER-1372 Attn: Mark Timmerman (630) 350-0370 Expires: October 1, 2010 Issued: March 1, 2009 Code: 2002 LABC GENERAL APPROVAL —Renewal - [TW Ramset/Red Head Anchors. 1, ITW Ramset/Red Head Self-Drilling Anchors 2 ITWRamset/Red Head Trubolt Wedge Anchors 3. ITW Ramset/Red Head Multi-Set If Anchors DETAILS ITW Ramset/Red Head Anchors are approved when in compliance with the description, use, identification and findings of Report No. ER-1372, dated March 1, 2000, of the ICBO Evaluation Service, Incorporated. ‘The report, in its entirety, is attached and made part of this general approval. The parts of Report No. ER-1372 marked by the asterisks are the parts modified by the Los Angeles Building Department from this approval. The conditions of approval are as follows: 1, Shall not be used in repair, retrofit and new construction of tilt-up wall anchors (in tension). 2. Shall not be used in repair, retrofit and new construction of masonry buildings in connection with wood diaphragm (in tension). 3. A 25% reduction in all allowable loads specified in the research report shall be taken in hold-down devices per Section 91.2315.5.6 of the 2002 Los Angeles City Building Code. RR 2748 Page 1 of 2 14008 Gs(Ree805) [AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER ITW Ramset/Red Head Re: ITW Ramset/RedHead Anchors. 4, The anchors shall be installed by the manufacturer's instructions, except as otherwise stated in this report. 5. The concrete shall have attained its minimum design strength prior to installation of the anchors. 6. Except for Table 3, the values shall not be increased one-third when considering wind or seismic loads. 7. Field load test 10 percent of the bolt after installation. The bolt shall develop 300 percent of the allowable capacities, if failure occur, then test 25 percent of the bolt. DISCUSSION: This general approval will remain effective provided the Evaluation Report is maintained valid and unrevised with the issuing organization. Any revisions to the report must be submitted to this Department, with appropriate fee, for review in order to continue the approval of the revised report. Addressee to whom this Research Report is issued is responsible for providing copies of it, complete with any attachments indicated, to architects, engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. ‘The status of the referenced Evaluation Report No. ER-1372 dated March 1, 2000, which is currently beyond its reexamination date is still valid. ‘The validity of the evaluation report was verified with ICBO. This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this approval have been met in the project in which itis to be used. pe Cow YEUAN CHOU, Chief Engineering Research Section 201 N. Figueroa St, Room 880 Los Angeles, CA 90012 Phone - 213-202-9812 Fax - 213-202-9942 Attachment: ICBO ES Evaluation Report No. ER-1372 (7 Pages) RR 2748 Page 2 of 2 EVALUATION REPORT Copyright ©2000 1GB0 Evaluation Service, te ICBO Evaluation Service, Inc. 5960 WORKMAN MILL ROAD. + WHITTIER, GALIFORNIA 90601-2299 A subsidiary corporation of the International Conference of Building Officials ER-4372 Reissued March 1, 2000 Filing Category: FASTENERS—Concrete and Masonry Anchors (066) ITW RAMSETIRED HEAD SELF-DRILLING, TRUBOLT WEDGE, AND MULTI-SET Ii CONCRETE ANCHORS, IW RAMSETIRED HEAD 4300 NORTH MICHAEL DRIVE WOOD DALE, ILLINOIS 60191 1.0 SUBJECT ITW RamseRed Head Sel-Driling, Trubolt Wedge, and Multi-Set Il Concrete Anchors, 2.0 DESCRIPTION 2.4 ITW RamsotiRed Head Self-Drilling Anchor: 2.44 Goneral: The ITW RamsetRed Head anchor s a self- dling concrete expansion shell anchor witha single conoex- pander. Both eloments are made from heat-treated steol, Tho steel for the body conforms to AISI C-12L1 4, and the steel for the plug conforms to AISI C-1010. The anchor has eightsharp teeth at one end and is threaded internally at the other end, ‘The outer surface of the tubular shell at the toothed end has annular broaching grooves and four milled slis. At ils threaded end, the anchor is provided with an unthreaded ‘chucking cone that has an annular break-off groove at its base for fush mounting. Anchor shell and expander cone are celectrodeposit zine and chromate-plated, 2.4.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 1 and 2. The anchors are installed by a Madol 747 Rolo-Stop Hammer, by airorelectricimpact hammer, or by hand. The anchor is used 8 a dil in forming the hole in normal-weight concrete. After the hole is formed, the anchor must be removed and the hole thoroughly cleaned. The hole depth is regulated by the dil chuck. A Red Head plug must be set into the bottom ofthe an- ‘chor prior to insertion inthe hole, The concrete anchor must bbe driven over the plug, to cause expansion of the anchor in the hole. The chucking end of the anchor is broken off with a hammer blow. Verification that the anchor has been installed properly is evidenced by the fact that the anchor does not project above the surface of the concrete and the red plug is Visible at the bottom ofthe hole. 2.2 ITW Ramset/Red Head Trubolt Wedge Anchor: 2.2.4. General: The Trubolt Wedge anchor isa stud bolt type Of drop-in anchor. The anchors are cold-formed ar machinest fcom zinc-plated’ and chromate-dipped carbon steel, hol- dipped galvanized carbon steel or stainless staal, Steel used to produce the anchors complies with AISI C-1015 to AISI €-1022 and AISIC-1213 carbon steels, Type 304 or Type 316 Stainless steels. Hot-dipped galvanizing complias with ASTM 193 Class C requirements. The expander sleeves are fabri- cated fromstainless steel or carbon steel meeting therequite- ments of Type 302 or AISI C-1010, respectively. Cold-formed anchor studs are available only for the ',-inch-, Yeinch grinch-,S/ginch- and SIyinch-diameter (6.4, 9.5, 12.7, 15.9 and 19.4 mm) wedge anchors. The anchor stud is threaded atits upper end and has a straight cylindrical section reduced in diameter, around which the expander sleeve is formed, A straight-lapered section enlarging toa cylindrical base acts to increase the diameter ofthe expander ring asthe studs tight- ‘ened in the concrete hold. The expander ring, whichis formed around the stud bolt, consists of a spiiting element with “coined” groove at each end. The expander ring is designed toengage the walls of the concrete hold as the tapered portion Of the stud is forced upward against its interior. 2.2.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 3, 4, § and 10. Holes must be predrilld in normal-weight or lightweight ‘concrete with carbide-tipped masonry dill bits manufactured ‘within the range of the maximum and minimum dri ip dimen sions of ANSI 8212, 15-1994, The anchors must be installad in holes the same nominal size as the anchor size, with a greater depth than the length of embedment desired, but no fess than tho minimum embedment. The hole must be cleaned out prior to instalation of the anchor. The anchor mustbe tappod nto the hole to the embedment depth desire, butnoless than the minimumembedment. A standardhexag- fonal nut and washer must be used over the material being fastened and the nut tightened until the minimum installation {orque, as indicated in Tables 3 and 10, is reached 2.3 ITW Ramset/Red Head Multi-Set l Anchor: 2.3.4 General: The Mull-Set anchors are designed to be installed in a predriled hole equal tothe anchor diameter. The anchor consists of a shell formed from carbon steel meeting the minimum requirements of AISI C-1213 and an expansion plug formed from carbon steel meeting the minimum require- ‘ments of AISI C-1010. The expansion end is divided into four equal segments by radial slots. The expansion plug is preas: sembled and is cylindrical in cross section, 2.3.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 6, 7 and 9. Holes must be predrilled in normal-weight or lightweight con- crate with earbide-tipped masonry drill bits manulactarod Within the range of the maximum and minimum dei tip dimen- sions of ANSI B212.15-1994. The anchors must be installed in predriled holes, the hole depth and diameter for each an- chor size being listed in Tables 6, 7 and 9. After the hole is dled, itis cleared ofall cutings. The anchor is set by instal- ling the expansion shell and then driving the cone expander with a setting fool provided with each anchor size, When the Evaluation reports of ICHO Evaluation Service, Ine, are ssed solely to provide information to Cass A members of ICBO, nln the code upon which the report ‘is haved. Evaluation reports are noo be construed a representing aesthetics or any ther atributs not specifically addressed noresan endorsement or econ ation for use ofthe subject report. This reports based upon independent tests or other technical daa submited by thespian. The ICBO Evaluation Service, ny technica saffhas reviewed the {est results and/or other deta, but doesnot posses ts facilites to make an independent verifaton. Theres no warranty by ICBO Evaluation Service, Ines express ‘orother matter inthe report or rimplids 5 toany “Find fo any productcoverd by thereport Ths disclaimer includes, ute not limited, merchantability Page 1 of7 Page 2 of 7 ER4372 cone expanderis criven down into the anchor, thelegs ofthe 4.0 FINDINGS. shell expand, 24 Design: Allowable static loads are as set forthin Tables 1,3, 6,9 and 10. /Mlowable loads for anchors subjected o combined shear and tension forces are determined by the flowing equation: (Pa/ PI + (Val VPP = 1 whore: Ps = Applied service tension load F, = Allowable sorvce tension load Ve = Applied service shear load Vj = Alowable service shear load. ‘The anchors cannot be subjected to vibratory loads Sources of such loadsinclude, for example, reciprocating en- gines, crane loads and moving loads due to vehicles, 2.8 Special Inspection: When special inspection is required, compliance with Section 1701.5.2ofthe code is necessary. The special inspector must be on the jobsite continuously during anchor installation to verify anchor type, anchor dimensions, concrete type, con- crete compressive strength, hole dimensions, anchor spac- ings, edge aistances, slab thickness, anchor embedment and tightening torque. 26 Identification: ‘The concrete anchors are identiied by their dimensional ‘characteristics, the anchor size, and by the length code stamped on the anchor. The conical-shaped expander plugs are colored red. See Figure 1 for additional details. Length Codes arein Table 8, Packages are identified with the anchor type andsize, the manufacturer's name and address, and the fname of the quality contro! agency, PFS Corporation. 3.0 EVIDENCE SUBMITTED. Data complying with the ICBO ES Acceptance Criteria for Ex- pansion Anchorsin Concrete and Masonry Elements (ACO1), dated January 1999. This report is subject to re-examinatior That the TW Ramset/Red Head fasteners described in this report comply with tho 1997 Uniform Building Code™, subject to the following conditions: 44 Anchor sizes, dimensions and installation are as set forth in this report. 4.2 Allowable shear and tension loads are as set forth In Section 2.4. 4.3 Calculations justifying that the applied loads com- ply with this report are submitted to the building of- ficial for approval. 4.4 Special inspectio ton 25, 4.5 Anchors are limited to installation in uncracked conereto, which is concrete subjected to tensile stresses not exceeding 170 psi (1.2 MPa) as in- duced by external loads, deformations and interior exposures. 46 Anchors are limited to nontire-resistive construc tion unless appropriate data is submitted to dem- onstrate anchor performance is maintained in fire- resistive situations. 4.7 Anchors aro manufactured at Highway 12, Michi- {gan ity, Indiana, with inspections by PFS Corpora tion (NER-QA25i). 48 Use of electroplated or mechanically plated carbon steel anchors is limited to dry, interior locations, Use of hot-dipped galvanized carbon steel is per mitted in exterior-exposure or damp environments. 4.9 Except for ITW Ramset/Red Head Carbon Steel and Stainless Steel Trubolt Wedge anchors embedded innormalweight concrete, as noted in Table 3, use of anchors in resisting earthquake or wind loads is beyond the scope of this report. 4.40 The anchors are not subjected to vibratory loads, such as those encountered by supports for recip: rocating engines, crane loads and moving loads duo to vehicles. provided as set forth in See: in two years. ‘TABLE 11TW RAMSETIRED HEAD SELF-DRILLING ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)!4 TERE T= Pinon | ee inched | toaecten® | aabeetba | shear tnsfaciont | wsbtetn Some Ta im Ti ais 210 35 650 a 365 * a Tye | in [55 70 [i035 30 0 % The 2h 315 0 1555 0 |* en Tin Ping 55 Ts 2s iss |* Ta T we 35 | 25 S15 a For Si: Vinh = 25-4 mm, 1 IDE= AAS, | pal = "The tabulated shear and tensile values are or anchors installed in normal-weight eerste having the designated ultimate compeessive strength a thet of nsallaton. Values have boon tabulated for bath AST A 307 and'A 249 bolt installed with be device 2 These tesion values ar applicable only when the anchors ave installed with special inspection asset ft in Section 2. 3 The minimum conerste thickness i My tines “The anchors are usted a8 flows embedment dep, othe embedtent del pl thro tics the anchor drt, whichever is greater: SLs *“ Conduct field test in accordance with condition # 7 of General Approval. Pagé 8017 ER4372 ‘TABLE 2—RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR ITW RAMSETIRED HEAD SELF-DRILLING ANCHOR edge Oltance Ebje Date Spacing "Sete Anchors pour, ‘eupeDiien Sine Lose ey Sein ae fio Ropes een ene sees) etsy “Nistor She “ines Seiten shee iy "he Th T Tig Me ic his a6 Vis 2g th The Phe Tg whe En Tn Bigg ea Be | Fy A 1 cI EU Fh sp Forte eh 254 mm, ‘Hiner interpolation may be wed fer intermediate pacing a age distances. TABLE 3—ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)!2488 oinstrer | “Sonduee™ | Sept spect | Specat g f nd rs 1190 5 760 | ae H eBonsstt oc zoo |X is 1780 Ta 15 ~ 35300 | 2) 3003 | 2505000) 4400s * = oa 7 3350 s_[4060"F] * a 7 SOF AF8 [2200 * 1, 300 Sip 5,820, 6595, 3,300 15800 Sx ay 2 ooo 1000 Se os SL * & ae BOOTS 14000 S95] — ° jae * Conduct Field Test in accordance with condition # 7 of General Approval ** revised by City of L.A. Page 4 of 7 ER4372 ‘TABLE 4—RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR TENSION LOADS FOR ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHORS? scion agp ao scinngesy aa fe sieht a i Th 1 3 Bh i a i the oh 4s Ty Mie aa : ws ¢ i 3 Me é 3 7; a wie F Th ws ais. alg 6 One ae [2 ae me a Te Fh he Be | a a me a mh, a i Bh oH tt oh Me Ma she Eu a ae a : a oe H i th, a i vn Thy Fy ee Bie 7 Oy i a aie a i sO ‘ 7 a Te am a zs a ie wh i HA ow me We sy ah aig Whe ¢ : : i ib th BD ah For Si [inch = 253m, Lines intipoltion maybe wd fr intent pacing and ge distances. Spacngs and edge dstaness sal be divided by 0.75 when anchors are placed i suc ighweight concrete in acordance with Table 10. TABLE 5—RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR SHEAR LOADS FOR ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHORS" on uy wrcron emsepueet ‘ca aig act . “lnc ren) (500 Figwo 2) {see Figo) {0 Fgu2) Aiea 0 Ty Ne 2 Te % Une 15h6 1 15g Us Wy 2s. Ph Wig a 3% 3 a Te Te she Bs sie am Sa Ea oh Te By Whe mh ~ The SMe ohe 3% EA % We Uh We ae om ne 3 ie Pa he 4s the ah he ih; Ea 7 Wy 7 3 | BA wi BA Th Ty wh En we or i Whe 2 ¢ WA = Not apticabe "Linear interpolation may be used for intrmedite spacing and edge distances. 2Spacings and edge distances shal be divided by 0.75 when anchors are placed in sutra ighcight conerete in acordance with Table 10. Page 5 of 7 ER4372 TABLE 6—ITW RAMSETIRED HEAD MULTL-SET II ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)1244 outleter | ouwctee | berms” | spect | Speci Speci spect, | Seca fe i wsfocton? | sfocion | sna tnscton | snow _| wnsbeain® | isbn | shor Te ip a0 | 210 | 210 295 300 TAs v5 325 Smeal 7s | a5 [10 a as} 1560 70 465 Te "ie z ws] ats | as 730 ws [207s ts 600, Tie s Big [ass [as] 8a Toso | tes | 2.755 | 1.378 510 | m7 1 The [2070 | hos [2620 920 | 3065 | 1.890 | as, a eee For St: Hach = 254 mm, 1 = 4.45 N, 1 p= 6.89 kPa "Tho tbulatd shar and inst values oe for anchors insaled in stone-agregate cones having he designated ulkimate compressive strength at thetic of iestalation. Values have bon tabulate fr both ASTAVA 307 and A 449 bots sald withthe devens me .- 2h oles are dilled with bits complying with ANSI 212. 15-1994. The bi dre eal the anchor Amster >The tension vals ar applicable any when the anchors ar installed with spec inspection asst forth in Socton 2. ‘The minimum coneret thickness s IV mes the embedonent depth, o the cmbodnent depth plus thee ties the anchor diameter, whichever sees Ae anchors ae israel as follows: Conduct field test in ccordance with condition #7 f General Approval ‘TABLE 7—RECONIMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR ITW RAMSETIRED HEAD MULTI-SET ll ANCHOR? =e ee oattier | HERE | Ei, | Beiee | cee ee |e eres: | ee | eee | ie i Te Th Wi Ta ie ay Whe 6 Th 7 i Tie tT | I O77 Ea Bi Th The 3 Big | For Si | inch = 254 mm, Linear interpolation may be used for interment spacing and edge distances. Spacings and edge distaees shall be divided by 0.75 when anchoe replace in sts lightweight conerte in eecordance with Table 9, ‘TABLE 8—LENGTH IDENTIFICATION CODES. f TENG OF AVEHOR TEST OF STOR 5] cove. Tah ‘ed | one. = Tomi x Black Wer Best N Bal, Ws <2i6 B White 223 S1e63 ° a3 216<229 ic Red dined 46 ? 39, no<2a1 D Grsen 525i, To<39 8 siyetb 3a < 254 5 Yalow siged 89 < 102 R ie 3345267 E ‘le aay voo< 114 Q Wen 461 < 305 G Purple ained tae 7 i Bab 50s <330 H Browa, 55th, 127 140 u ben 330 © 348 t Onnge Sine Wo 152 v 3s <381 1 WA cay 152 165 w a1 = 408 kK Hin oid tes 178 x io £439 t WA tenn His < 191 y 433437 Mw NA iy'ch 191 <203 z 4576483 Page 6 of 7 ER-372 ‘TABLE 9—ITW RAMSETIRED HEAD MULTLSET II ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)'244 ‘sooo e308 ocr owmcrer | olMtede | “Muerte” Wan Speaigr | thou Spear Tih Spear acy | iver | Yaepand! | ™iteped Tneedicn | Shear is Ty The 965 482 35 105 Te Tq [0 310 300 Tas 3h. Tis ai 1370 735 180 1.460 Me t whe 2,150, 135 2,005 Tom 2280 For SH: |inch=254 mm, 11bf= 445 N, 1 psl= 689 kPa "The tabulated shoarandtnsl ales are for anebors istlledin structural lighewsght covert having the designated ultimate compressive strength at thetic ofinta akon. Vics have ben abu for both ASTM A 30? and A 489 oll istaed withthe doce 2the hoes are dled with bts omplying with ANSI B212.15-1994 The bit direter equals the anchor dtm DThese tension vales are applicable oly when the anchors ae installed wi speci inspection a set fort in Seton 2. “Installation details are in Figure 3. Spacing and edge distances ae in Table 7 as wofed by Footnote 2, TABLE 10_ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)!2¢ oie Sonace eiteetne | Wh Seca Tt since ‘wien Speciat | Without Speci! ee i We ap oH #8 Te 90 q 1,500 730 2310, 590 3 190 Ey Be 2 a} 8 BE 30 a ue [oe [aM 308 3 WA = Not applicable, "The tabulated shea ad tensile values are for anchors installed in strctral lightweight coerte having the designated compressive strength tthe time of installation. 2 the hols are drilled with bits complying wih ANSI B212.15-1994, The bit diameter equal he anchor diameter. Sthese tension values are applicable only when the anchors ar installed with spec al inspection asst oth in Scion 25 Snsalation dtl ae in Figure 3. Spacing and edge distances are in Tables 4 and Sas wodiied by Footnote 2 SeltDrils (bat size) ‘rubolt Wedge Anchors Carbon Stoel (anchor size x length) Mulset I Ru-Carbon Stoo! {bat se) FIGURE 1—IDENTIFICATION SYMBOLS FOR THE VARIOUS ANCHORS * Conduct Field Test in accordance with condition # 7 of General Approval eee Page 7 of 7 R372 0.60 0.20 2 et E FIGURE 2—LOAD FACTORS FOR TRUBOLT WEDGE ANCHOR SHEAR LOADS AT REDUCED EDGE DISTANCES (See also Table 5) cua, qt UuciTwerci coucrere ony wreup.tan, MULTISETH moor | 20a sree. eck STEEL DECK WITH LIGHTWEDHT CONCRETE FLL = DEPTH OF eusEDMENT For St: | inch = 25.1, FIGURE 3—TRUBOLT AND MULTI-SET Il ANCHORS IN LIGHTWEIGHT CONCRETE (f= 3,000 psi) ‘AND STEEL DECK WITH LIGHTWEIGHT CONCRETE FILL (7 = 3,000 psif

Вам также может понравиться