CIVIL STRUCTURAL DRAWINGS

PROJECT:

NEW FACILITY BUILDING

CLIENT :

DESIGN CONSULTANT :

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

GENERAL NOTES :-

1
17
5

00

17
5

20

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

C19

17
5

90

5
17

17
5

50

50

20
0
0

20

22

0
20
22
5

5
22

17
5

22

17
5

22

C22

17
5

22

C7

C5

C12

23
225

2433

225

225

3835

125

200

26

C7

225

C7

C6

24

C7

C1

C5

4615

C3

175

200

50

525

525

C3

225

225

C1

5260

200

200

225
200

225

C6

C6

REV. NO.

C17

DATE

DWN

ISSUE OR REVISION

CLIENT:-

225
175

200

200

225

C6

C6

C6

175

5460

200

C17
300

300

300

300

6000

6000

S1

175

225
175

175

175

C9
175

C20

C9

PROJECT:

NEW FACILITY BUILDING

C18

6000
6900

DRAWING TITLE :

COLUMN LAYOUT PLAN

400

C10

175

6000

C18

175

3790

U1

C18
175

R1

75

C6

175

C9

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

31

C6

175

53

Q1

225

175

C9

175

175

C11

C2

725

175

C9

6000

C2

725

725
175

C9

175

175

175
6000

175

C9

C2

175

3790

175

C9

C2

725

725

725
175

C9

C2

175

5883

C2

39

4115

175

C9

175

175

C23

C2

725

225

C6

175

175

175

C23

Design Group Engineering Consultants

1835

300

175

300

175

175

DESIGN CONSULTANT :-

225
300

175

C17

175

175

175

175

22

2790

17

175

6000

175

C5

C6

175

175

200

C17

3025

C22

20
20
0
5

C6

175

C2

4025
1275

175

C7

225

175

600

C2

17
5

17

C6

C6

30

33

5
5

175

225

225

175

32

17

45

17

300

300

175

29

22

C17

C7

6800

175

125

17
5

0
20
22
175

C6

200
1975

175

28

1990

27

C22

C21

C22

175
175

200

175

17

00

C7

C19

C22

17
5

C19

40

C15

175

3325

69
5

17

22
5

C22

20

0
45
5

22
5

17

C19

C17

C7

17

C19

20

C5

C2

200

600

600

20

17
5

300

90

C18

C22

C4

80
4

13

200

175

25

17
5

C22

20

C21

200

47

17

20

22

56

17

33

20

300

C5

125

17

62
40

17
5

C21

90

17
5

C14

15

22

17

175

175

25

C7

175

175

1021

22

2675

17

C7

C17

C4

17

17

22

C20

17

C19

LIFT

C5

C21

17

C22

30

17

17

17
5

17

C20

17

38
5

C17

17

17

C15

C8

45

C14

C4

20

22

22

C21

C23

45
0

42

21

30

17

14

17
5

17

C21

95

68

0
20

C18

17
5

C22

C4
0

30
0

22

N
5
17

C17

00

17
5

0
0

17
5

300

175

30
5

45
22
5

20

200

175

17

7. GRADE OF BLINDING CONC. SHALL BE- C15

17

C22

C4

17

73

17

20

175

175
3765

17

20

0
45

22
5

58

45
0

20
0
0

22
5

29
45

30

17

53

C2

00

C4

C21

C15

58

17

C17

C5

C2

C4

30
32

22
5

300

C2

20

20
5
27

17

C15

C2

17
0
45

20
0

C4

30

58

00

C8

F1

C18

45
0

60
00

17
5
5

5
5

200

300

00

C22

C1

C5

40

17
5

C21

17

5
22

6967

600

175
20

30

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

6000

C17

C5
300

C6

17

17

22

30

A1

200

600

300

175
17

C5

C4

00

C18

30

17

C21

600

C9

200
175

200
175

7
5 00
17 2
5

22

175

11

21

C17

175

20

60

5
25

11531

13

22

C23

17
5
5

5
17
5

53

C17

22

84

C17

C17

22

17

15

5
22

75

C8

C13

17

20

20

C17

225

75

00

C16

22

C8

30

C23 1

22

M2

175

17

00

17

25

17
5

17

C7

21

C13

22

20
0

600

5
17

C8

53

225
17480

20

17

22

0
20

C17

17

C8

30

175

0
20

19

22

C17

17

22

51
23

77

C23

17

30

20

17

24

22

75

C17

17

C17

22

17

22

C8

17

13

17

20

C17

17

22
5

C17

22

C13

17

5
22

C17

17

C23
175

M1

5
17

C17

17

22
5

C14

20

C18

C4

20

C18

17

5
17
5
17

C17

20

00

C22

17

0
20
17

50
01
17
5

30
00
5
17

C17

5
17

C7

C17

5
17

17

30
0

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

60

C22

3352

175

175

25

C23

C21

175

C7

C14

4
27

20
00
76

17

20

17
5

3000

17
5

22
5

17

C22

175

C7

00
76

C17

17
5

C19

3000

175

C7

17

18
00
76

C23

15

83

C17

22

15

16

17

12

17

175

17

225
41

C23

C17

3000

50
57

C22

C22

3100

17

175

50

175

17

C7

14
59

C23
175

13

C17
C7

11

12

17

17

22
5

17

175

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

00

30
0

20

C23
175

17
5

10

C7

3100

32
50

17

C22

C22

175

17

17

20

175

60

C18

45
0

00

C17

17
5

17

50

41
77

17

45

20

20
0

C7

17

20
0

80

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

00

C21

C22

5
47

60

C18

17

20
0

50
00
0

17
5

28
73

54
44

17

20

17
5

C22

50
0

17
5

17
5

0
57
9

C22

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

17

57

2775

3225

X1

FOR COLUMN SCHEDULE,


SEE DRG. NO. S-02

COLUMN LAYOUT PLAN


DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 04

00

GENERAL NOTES :1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE
STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

COLUMN SCHEDULE
MAIN BARS
TIES

T20 - 12 NOS.
T10 AT 150 C/C

T20 - 20 NOS.

T16 - 14 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T10 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.
3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN
METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

FIGURE

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

SIZE
MIX OF CONC.

MAIN BARS
TIES

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

400x400
350x350

900x600

400x400

400x400

350x350

C-35

C-35

C-35

C-35

C-35

C-35

T20 - 12 NOS.

T20 - 20 NOS.

T16 - 14 NOS.

T16 - 20 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T16 - 9 NOS.

T20 - 8 NOS.

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C
261

622

44

350

3
44

350

FIGURE

533

350

SIZE

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

400x400

350x350

900x600

900x600

400x400

400x400

350x350

SEE SKETCH

SEE SKETCH

MIX OF CONC.

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

MAIN BARS
TIES

T20 - 12 NOS.

T20 - 20 NOS.

T16 - 14 NOS.

T16 - 20 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T16 - 9 NOS.

T20 - 8 NOS.

T16 - 13 NOS.

T25 - 12 NOS.

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

261

622

400x400

350x350

900x600

900x600

400x400

400x400

350x350

350x350

350x350

MIX OF CONC.

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

MAIN BARS
TIES

T20 - 12 NOS.

T20 - 20 NOS.

T16 - 14 NOS.

T16 - 20 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T16 - 9 NOS.

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

350

40

44
533

350
SEE SKETCH

802

SEE SKETCH

SEE SKETCH
C-35

C-35

T20 - 8 NOS.

T16 - 13 NOS.

T25 - 12 NOS.

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

261

622

350

350

44

44

350

FIGURE

593
40

SIZE

350

3
44

350

FIGURE

593

533

350

SIZE
MIX OF CONC.

400x400

900x600

900x600

900x600

400x400

400x400

350x350

350x350

350x350

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

T16 - 8 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T20 - 12 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

SEE SKETCH
C-35

SEE SKETCH
C-35

802
SEE SKETCH
C-35

C-35

COLUMN SCHEDULE
MAIN BARS
TIES

FIGURE

SIZE
MIX OF CONC.
MAIN BARS
TIES

FIGURE

SIZE
MIX OF CONC.
MAIN BARS
TIES

C-35

350x350

350x350

400x400

400x400

400x400

C-35

C-35

C-35

C-35

C-35

T16 - 12 NOS.

T16 - 8 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T20 - 12 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

REV. NO.

DATE

DWN

ISSUE OR REVISION

CLIENT:-

FIGURE

DESIGN CONSULTANT :-

SIZE

400x400

400x400

350x350

350x350

400x400

400x400

400x400

350x350

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

MIX OF CONC.

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

MAIN BARS
TIES

T16 - 12 NOS.

T16 - 8 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T20 - 12 NOS.

T25 - 12 NOS.

T20 - 12 NOS.

T16 - 8 NOS.

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

T8 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T8 AT 150 C/C

PROJECT:

NEW FACILITY BUILDING


FIGURE
DRAWING TITLE :

COLUMN SCHEDULE
SIZE
MIX OF CONC.

C-35

C-35

400x400

400x400

350x350

350x350

400x400

400x400

400x400

350x350

C-35

C-35

C-35

C-35

C-35

C-35

C-35

C-35

FOR COLUMN LAYOUT PLAN,


SEE DRG. NO. S-01

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 04

00

GENERAL NOTES :-

1350

F8

25

80

13

70
0

13
25

60

13
2

80
0

80
0

AL
L
.W

10
50

F7

10
50

90
0

F6
5

10
50

0
90

F6
5

50

90
0

10

50
10

90
0

10
50

F6

92

25

60
0

10

75

25

0
60

70

10
90

12

0
80

F6
5

10

75

F5

70
0
0
60

40
62
0
80

80
0

22
2790

80

F7

80

1200

655

23
800

1350

1225

1475

F7

1450

24
800

F7

1050

800

F7

26

685

325

1475

3835

1250

F1

F7
F1

1100

1100

1125

F4

F4

REV. NO.

SCHEDULE OF FOOTING
1100

1100

1125

F4

F4
5460

1350

1350

1350

1075

700

3790

700

R1

6000

700

6000

700

S1

6000

700

6000

700

700

F8

1075

1625

1625
0

90

F8

F5
F6

700

F6

F8
700

F6

900

900

1050

100

F5

DWN

ISSUE OR REVISION

CLIENT:-

FOOTING SIZE

FOOTING
MKD.

F1

2900

2900

600

T20 AT 175 C/C T20 AT 175 C/C

T12 AT 200 C/C T12 AT 200 C/C

F2

2700

2700

550

T16 AT 150 C/C T16 AT 150 C/C

T12 AT 200 C/C T12 AT 200 C/C

F3

2500

2500

500

T16 AT 150 C/C T16 AT 150 C/C

--

--

F4

2200

2200

450

T16 AT 150 C/C T16 AT 150 C/C

--

--

F5

2100

2100

400

T16 AT 150 C/C T16 AT 150 C/C

--

--

F6

1800

1800

400

T16 AT 200 C/C T16 AT 200 C/C

--

--

F7

1600

1600

400

T12 AT 150 C/C T12 AT 150 C/C

--

--

F8

1400

1400

300

T12 AT 150 C/C T12 AT 150 C/C

--

--

F9

1200

1200

300

T12 AT 150 C/C T12 AT 150 C/C

--

--

CF1

4055

3150

900

T16 AT 150 C/C T16 AT 150 C/C

A
(BOT. REINF.)

B
(BOT. REINF.)

C
(TOP REINF.)

REMARKS

(TOP REINF.)

T16 AT 150 C/C T16 AT 150 C/C

DESIGN CONSULTANT :-

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

PROJECT:

NEW FACILITY BUILDING


DRAWING TITLE :
LIFT PIT FDN.

FOUNDATION PLAN

900

F6
3790

U1

DATE

900

900

F6

900

FOUNDATION PLAN

900

31

925

900

F8

F2

700

F8

F2

700

1625

1625

F8

F2

700

F8

F2

700

700

F8

F2

1625

1625
700

F8

F2

F6

1835

1350

900

5883

1350

1050

Q1

F8

F2

1625

F6

700

700
700

1350

900

1350
900

900

1050

700

F5

F7

700

1075

835

1990

82
5

92

92

10

F5

F3

1050

3025

300

F5
25

F7

1050

6000

SECTION 2-2

25

50

80

75

1050

F4

160

250 100

F9

60
0

50

1100

900

BLINDING CONC.

200

60
0

F5

F5

10

855
1300

1200

900

6000

100 250

1050

4115

T10 AT 200 C/C


T12 AT 200 C/C

RE
T
C.

50
0
90

00
11

10

F6

1050

F5

F7

600

90

825

F9

600

33

F9

1025

1075

1275
825
6000
6800

900
300

GRADE SLAB

47

F9

00

F4

1450

F510

F8

F2

F1

60
0

80
4

1025

775

10

92

10

F5

F7

900

F5

T10 AT 200 C/C


32

F9

F7
20

1125

30

+200

60
0

1
80 590
0
13

1125

775

9. SOIL BEARING CAPACITY OF SOIL IS CONSIDERED AS

925

700
4025

700

25

50

50

10

25

12
11

00

F4

1125

T12 AT 200 C/C


WATER PROOFING AS/SPECS.

80
0

1025

1225

55

F5

F5

29

GRADE SLAB

50

11

F6

1350

F3
50

11
0

CF1

F7

F6

80
0

0
80

C.
10
50
5

12
2

RA
MP
UP

00

F4

11
2
40

F5

28

+1100

13
25

10
50
10
50

0
10
5

0
60
62

10

F5

12

1450

800

1975

F8

27

11

1100

700

F8

00

70

69

0
70

700

3325

25

70

F5

F4

1050

F2

1350

10

10

50

4815
825

F8

50

10

800

F3

00

F7

F6

LIFT

F3

10

90
0

825

F7

8. GRADE OF BLINDING CONC. SHALL BE- C15

30

F8

10

F5

F5

42

56

31

00

825

800

1075

F8

80

0
70
0
50 67
0

F4

11

F2

1350

F3

14

F9

60

F2

F6

2675

700

825

82

700

70

95

68

F7
0
80

1021

70

7. GRADE OF CONC. SHALL BE- C-35

00

F5

30

N
1225

20

50

12
5

25

11
00

F3

F3
75

60

1250

F3
F2

1350

F1

6000

1450

1250

1225

1250

F2
1200

1200

1575

F1

10

33860
5

F7

50

F4

1200

07

80

82

1075

5
0

13

1250

F3

F2

1050

58

10
50
10
50

11
25
80

33

1200

20

70

20

1225

1225

725

800

F3

F5

50

80

29
4
0
70

F7

F2

67
5
14

70
0
58
9

11

50
13
5

92

700

F7

10

F8
F9

53

0
80
80

50

1250

F5

F7

F7

30

80
0

10

53
25

F7

0
80

F8

73

C1

70

F6

0
80

800

92

F7

32

12

75

11

70

13

00

50

R.

10
50
60
00
0

80
0

F5

F6
1250

40

5
87
60
0

0
70

80

87
5

15

50

F8

A1

70

84

0
80

70

10

50

12

00

00

F8

80

F7

F5

75

F5

58

30

F7

F3

50

13
25

10
50
0
10
5
50
00
50
10
0

98
5

25
75
10

92
5

10

00

11

F8

21
0

70

F7

F8

90

00
76

30

80
0

F6

M2

13

11

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

F5

70
0

00

15

20
0
80

F8

F6

F3

10

90

00

F7

13

0
70

F8

00
76

70

80

F8

00

12
50

30

70

92

53
21

50

50

19
0

80

F2

10

F7

5
13

90

F5

70

00

5
07

25

50

00
76

F5
M1

80

13

10

F8

80

00

25

51

F5

47

F8
F5

10

10

F4

77

25

00

00

F7

24

10

23

F7

700

12
50

00

70

27

17
18

SCALE- 1:20

8
12

F4

00

F4
F6

22
11

80

16

15
41

11

15

F6
0

TYP. COLUMN FOOTING PLAN

00

80

F4

F7

F5

F5

F8

10

87

0
95

100

90
0

92

100

14
5

10
75

10

75

50

00

F5
87

EQUAL

11
00
11

700

00

11
00

80

F5

F9

12
75

10
50

10
50

80

F4

10

F8

11

60

50

11

3352

F7

100

0
12
5

11
00

90
0

50
01
0
30
0

EQUAL

REINFORCEMENT - A

10

50

700

10
5

E
80

60

11

F5

00

F7

50

700

EQUAL

F7

60

50

F5

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

10

F5

F6

3000

80

700

F8
00

D
80

10

50

F5

90

3000

13

F8

10
50

50

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

00

F5

10

700

C
L OF FOOTING/COL.

EQUAL

F4

10

F5

3000

10

75

80
0

700

700

90
0

50
57

100

F8

90
0

F6

700

700

11

12

25

F3

F8

FOOTING LINE

F8

12

70
0

70

50

3100

CL OF FOOTING/COL.

F6

700

SECTION 1-1

90
0

10

10

60

F7

F5

F5

700

3100

10

695

WELL COMPACTED EARTH

REINFORCEMENT - B

F6

P.C.C BED LINE

80

41
77

100

SECTION 3-3

100

A/B

47

90

F7

100THK BLIND CONC.


C-15 WITH 1000
GUAGE POLYTHENE SHEET

50
0

50

F5

5
88

250 100

REINFORCEMENT-B

(TYP)

100

200

T10 AT 200 C/C


T12 AT 200 C/C

80

44

32
50

100 250

REINFORCEMENT -A

50xd

54

10

80
0

00

80

WATER PROOFING
AS/SPECS.

REINFORCEMENT-D

BLINDING CONC.

28
73

REINFORCEMENT -C

F5

F4

11

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

60
00

F7

50

50
00

300
300

COL.BARS

100

OR TO FIRM SOIL

1500(MIN.)

COL.TIES
WATER PROOFING
AS/SPECS.

10

80
0

80
0

3
GRADE SLAB

F6

90
0

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

11
00

+200

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

PLINTH BEAM

90

5
92
57
90

T10 AT 200 C/C


T12 AT 200 C/C

WHICHEVER IS LOWER

57

F9

900

100THK BLIND CONC.


C-15 WITH 1000
GUAGE POLYTHENE SHEET

60
0

80
0

60
0

20
00

FFL (AS/ARCH. DRG.)

N.G.L / F.G.L.

1100

GRADE SLAB

13
25

200

GROUND FLOOR SLAB

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

(AS/RAMP SLOPE)

T10 AT 200 C/C

1025

+1100

F6

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

2775

3225

M.S.

CH.

P.M.

D.R.K.

04.06.2015

X1

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 01

00

GENERAL NOTES :-

SCHEDULE OF PLINTH BEAMS


REMARKS.

2-T16

3-T20

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3+3 T12 SIDE FACE BARS

PB-4

300

900

3-T20

3-T20

3-T20

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3+3 T12 SIDE FACE BARS

PB-5

250

750

2-T16

2-T16

2-T16

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

1+1 T12 SIDE FACE BARS

PB-6

250

600

2-T16

2-T16

2-T16

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

2
PB

7
PB

0
PB

PB

8
PB

00

PB

6
UP

6
PB

42

PB

PB
2

38

UP

33

UP

56

PB
8

PB
3

PB

PB
1

PB
8

6
PB

90
13
2

RA
MP
UP

PB
6

PB
PB2

PB2

PB1

PB6

PB6

PB6

PB6

PB6

PB6

PB6

23

+200

PB6

PB8

3835

PB6

26

+200

PB6

PB6

Z
PB6

PB6

PB8

PB7

PB6
1275

PB6

SEC. 6-6 REVISE AS/CLIENT'S

01

PB5

11.08.2015 REQMNT.(RCC WALL REMOVED)

PB6
PB6

PB5

6000

PB6

REV. NO.

+200

PB6

4025

PB6

PB6

PB11

PB7

PB7

DATE

DWN
DWN

ISSUE OR REVISION

CLIENT:-

PB5

5460

PB7

PB5

3025

30

PB5

PB5

965

PB9

6800

PB6

PB6

PB6

PB6

PB6

PB6

PB6

PB6

PB6

PB6

PB6

5883

3790

6000

6000

6000

6000

UP
PB6

PROJECT:

1835

PB

4115

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

PB6

PB6

PB6

PB6

PB6

PB6

31

PB11

PB6

PB6

PB11

PB6

33

PB6

PB8

NEW FACILITY BUILDING

PB10

Q1

R1

S1

U
6000

PB

PB10

PB6

32

PB6

DESIGN CONSULTANT :-

Design Group Engineering Consultants

PB8
PB6

29

PB7
PB7

28

PB11

PB7

PB6

3325

00

27

1975

69

UP

1990

6
PB

5
PB

24

PB8

PB6

2675

95
68

1021

PB8

PB8

8
PB

PB8

PB6

22
PB

PB6

PB2

PB6

07

1
PB

PB

PB7

25

PB
6

PB
6

PB

PB11

PB6

80

LIFT

11

20

PB2

PB6

+200

PB

15
7

PB

6
PB
6

PB

PB

PB

PB
2

C1

PB6

PB6

PB7

PB

+200
58

PB

6
PB

PB

14

32

73

PB

00

PB
2

PB

PB

PB

11

PB6
PB

PB

PB

PB
7
25

58

UP

PB
11

30

PB
6

PB

2a
PB

PB

13

58

PB7

PB

53

20

+600

PB

PB
1

1
2a
PB
2a
PB

+200

00

PB
2

M2

UP

20

6
PB

PB
53 7
21

2a
PB

84

5
PB

PB

A1

1
PB

7
PB

PB

15

21

+200

00

30

7
PB

PB
2a

2a

1
PB

PB

PB

30

PB
2

PB
3

6
PB

2
13

PB
2

PB

PB

19

20

8
PB

00

5
PB

+1100

M1

7
PB

7
PB

PB
51 7
23

5
PB

5
PB

+1100

PB

PB

30

5
PB

PB

17
18
00
76

0
76

PB

22

PB

PB

6
PB

5
PB

6
PB

47
27

PB

PB

3352

PB2

15

16
83
12

PB

77

90

+200

24

PB

47

+200

PB

50
01

BEAM

PB

PB2

14

PB
7

PB
7

PB
7

+1000

2a

PB

PB

3000

2a

50
59

3000

PB
7

8. GRADE OF BLINDING CONC. SHALL BE- C15

PB
PB

+1000

UP

41

PB

15

76

PB
7

PB
7

+1100

PB
PB2

PB

PB
6

+1

PB2

RIGHT
(R.H.S.)

3000

PB

11

13

+1100

PB
7

12

PB

00

50
57

PB2

11

PB5
3100

RIGHT
(R.H.S.)

3100

PB2

10

SUPPORT REINFORCEMENT DESIGNATION

PB
PB
8

00

PB

40

2L T8 AT 150 C/C

62

2L T8 AT 200 C/C

PB
6
PB
11

2L T8 AT 150 C/C

7. GRADE OF CONC. SHALL BE- C-35

2790

--

PB6

--

AL
L

2-T12

G
30

.W

2-T12

00

R.
C.
C.
RE
T

2-T12

PB
6

450

200

PB

PB-11

PB

PB
6

2L T8 AT 150 C/C

PB6

2L T8 AT 200 C/C

20

PB
6

PB
7

2L T8 AT 150 C/C

F1

--

40
00

PB

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

PB

--

2-T16

PB

--

00

PB

RA
MP
UP

2-T16

60

600

80

PB

250

PB
2

PB-10

PB6

2L T8 AT 150 C/C

PB
6

2L T8 AT 200 C/C

PB
2

2L T8 AT 150 C/C

--

PB

--

2-T16

PB

PB

2-T12

PB8

2-T16

PB

PB
6

24
00

700

47

PB

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

00

UP

18
45

200

60

PB
6

PB-9

2L T8 AT 150 C/C

PB

2L T8 AT 200 C/C

2a

2L T8 AT 150 C/C

PB

--

PB
11

--

45

2-T16

29

2-T12

2-T16

11

600

PB
6

PB

200

53

PB-8

30

2L T8 AT 150 C/C

50
00

2L T8 AT 200 C/C

2L T8 AT 150 C/C

2-T12

PB

2-T12

PB

2-T16

44

60
00

2-T12

54

PB
2

2-T16

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

PB
7

600

00

PB

PB

200

41
77

PB-7

60

PB
6

PB
11

3-T20

PB

900

300

+1100

PB

PB-3

5+5 T12 SIDE FACE BARS

PB

2L T8 AT 150 C/C

2L T8 AT 200 C/C

PB

2L T8 AT 150 C/C

2-T12

PB

2-T12

PB

2-T20

2-T12

PB

2-T20

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

PB

1200

60
00

PB

250

PB

PB
6

PB-2a

PB

5+5 T12 SIDE FACE BARS

PB
11

2L T8 AT 150 C/C

16
35

2L T8 AT 200 C/C

2L T8 AT 150 C/C

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

PB

2-T12

2-T12

PB

2-T20

11

--

PB

2-T20

24
00

1200

57
90

250

PB-2

PB

6+6 T12 SIDE FACE BARS

11

2L T8 AT 150 C/C

PB

2L T8 AT 200 C/C

22
95

2L T8 AT 150 C/C

50
00

2-T12

2-T12

PB

2-T20

2-T12

PB
1

2-T20

50
00

1500

250

LEFT
(L.H.S.)

B
PB
2

PB

PB-1

BEAM

57
90

6000

RIGHT SIDE (L/3)

RHS

MIDDLE

PB

LHS

LEFT SIDE (L/3)

20
00

EXTRA AT CONTINUOUS SUPPORT

RA
M
UP P

STRAIGHT

CURTAIL

STRAIGHT

PB

DEPTH

STIRRUPS

28
73

TYPE
WIDTH

TOP REINF.

BOTTOM STEEL

32
50

SIZE(mm)

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

PB6

PLINTH BEAM FRAMING PLAN


6000

FOR SECTIONS DETAIL,


SEE DRG. NO. S-05

PB6
3790

U1

DRAWING TITLE :

2775

3225

X1

PLINTH BEAM FRAMING PLAN


DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169
DRAWING NUMBER:

S- 04

SCALE:
1:200

SHEET:

A1
REVISION:

01

GENERAL NOTES :-

12x20THK MASTIC SEALENT(TYP.)

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

+1100

12THK FLEXEL BOARD (TYP.)

+1100

+1100

GRADE SLAB

STEPS IN BLOCK WORK

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

STEPS IN BLOCK WORK


GRADE SLAB

RISER = AS/ARCH. DRG.


TREAD = AS/ARCH. DRG.

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

900

GRADE SLAB

RISER = AS/ARCH. DRG.


TREAD = AS/ARCH. DRG.

+200

PLINTH BEAM AS/DETAIL


WATER PROOFING AS/SPECS.

300

+200

+200

WATER PROOFING AS/SPECS.

1100

1100

RCC RET. WALL

GRADE SLAB
250

WATER PROOFING AS/SPECS.


GRADE SLAB

100 TYP.

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.
7. GRADE OF CONC. SHALL BE- C-35

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

100

SECTION 1-1

BLINDING CONC.

100

400

400

BLINDING CONC.
100

BLINDING CONC.

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

250

300

GRADE SLAB

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

8. GRADE OF BLINDING CONC. SHALL BE- C15

SECTION 2-2

SECTION 5-5

100 TYP.

+1100
+1000

STEPS IN BLOCK WORK

200

200

GRADE SLAB
RISER = AS/ARCH. DRG.
TREAD = AS/ARCH. DRG.

12x20THK MASTIC SEALENT

12x20THK MASTIC SEALENT

20THK FLEXEL BOARD

20THK FLEXEL BOARD

150THK FLOOR SLAB WITH SINGLE


LAYER A-252 MESH REINF.
F.F. LVL.

PLINTH BEAM AS/DETAIL

150THK FLOOR SLAB WITH SINGLE


LAYER A-252 MESH REINF.
F.F. LVL.

WATER PROOFING AS/SPECS.


N.G.L./FGL.

100THK BLIND CONC.


C-15 WITH 2 COATS OF
BITUMINUOUS + 1000 GUAGE
POLYTHENE SHEET

100

BLINDING CONC.

100

400

BLINDING CONC.
WELL COMPACTED EARTH UPTO
98% STANDARD PROCTOR DENSITY

SECTION 3-3

TYP. SECTION FOR INTERNAL PLINTH BEAM

150THK FLOOR SLAB WITH SINGLE


TOP LAYER A-252 MESH REINF.

200

2-T16

F.F. LVL. AS/ARCH. DRG.

50

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

2-T16

T8 AT 200 C/C (STRPS.)

BLINDING CONC.

100

100

500

500

BLINDING CONC.

BLINDING CONC.

TYP. SECTION FOR EXTERNAL PLINTH BEAM

GRADE SLAB

T8 AT 200 C/C (STRPS.)

SOLID BLOCK WORK

100

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

150THK GRADE SLAB WITH SINGLE


LAYER A-393 BRC MESH REINF.

2-T16

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

100

100

100

400

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

200

+200

SOLID BLOCK WORK

100

PLINTH BEAM AS/DETAIL

WELL COMPACTED EARTH UPTO


98% STANDARD PROCTOR DENSITY

400

100

300

100THK BLIND CONC.


C-15 WITH 2 COATS OF
BITUMINUOUS + 1000 GUAGE
POLYTHENE SHEET

2-T16

100THK BLIND CONC.


C-15 WITH 1000
GUAGE POLYTHENE SHEET
WELL COMPACTED EARTH UPTO
98% STANDARD PROCTOR DENSITY

TYP. GROUND FLOOR GRADE SLAB DETAIL

SECTION 4-4
01

11.08.2015

SEC. 6-6 REVISED


AS/CLIENT'S REQMNT.

DWN

REV. NO.

DATE

ISSUE OR REVISION

DWN

CLIENT:-

+600 (BACK STAGE)


DESIGN CONSULTANT :GRADE SLAB

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

+200
GRADE SLAB

PROJECT:
PLINTH BEAM AS/DETAIL

PLINTH BEAM AS/DETAIL

NEW FACILITY BUILDING


DRAWING TITLE :

TYP. PLINTH BEAMS SECTION DETAILS

SECTION 6-6

FOR SETIONS LOCATION,


SEE DRG. NO. S-04

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169
DRAWING NUMBER:

S- 04

SCALE:
1:200

SHEET:

A1
REVISION:

01

GENERAL NOTES :A

F.F.L.

57

90

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.
60

57
90

F.F.L.

20
00

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

00

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

3
60

00

50
00
44

40

LJ

LJ

41
77

LJ

18

IJ - INDUCED JOINT

L
C
RC

LJ

UP

LJ

32

83

M1

53

14

73
58

RA
MP
UP

00

23

47

58

30

51

27

RA
MP
UP

53
30

00

12

WA
L
T.

LJ

LJ

29

14

17

LJ - LONGITUDINAL JOINT

30

22

LJ

UP

45

3352

20

00

15

RE

00
30

3000
13

30

15

16

41

LJ

LJ

50
01

3000

LJ

LEGEND

42

21

38

53

M2

00

25

15

76

19

A1

UP

90

13

20

80
4

33

56

00

C1

UP

LIFT

11

13

IJ

LJ

62

84

20

15

40

76

LJ

3000

LJ

50

LJ
LJ

59

90

LJ

LJ

LJ

LJ

77

8. GRADE OF BLINDING CONC. SHALL BE- C15

LJ

LJ

24

LJ

60
00

LJ

LJ

UP

LJ

LJ

32
50

50
57

3100

TYP. INDUCED JOINT (IJ) DETAIL

00

LJ

12

7. GRADE OF CONC. SHALL BE- C-35

47

LJ
LJ

G
30

LJ

11

F1
00

LJ
LJ

00

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

20

3100

SLAB THK.

00

LJ

80

F.F.L.

13

60

50
00

47

10

LJ

28
73

UP

LJ

54

50
00

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

00

RA
M
UP P

TYP. LONGITUDINAL JOINT (LJ) DETAIL


(TYPE -2)

60

TYP. LONGITUDINAL JOINT (LJ) DETAIL


(TYPE -1)

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

RA

MP
UP

00

76

22
07

2790

20

21

IJ

23

6000

IJ

IJ

IJ

58

IJ

20

IJ

IJ

LJ

LJ

LJ

LJ

LJ

LJ

LJ

24

27

IJ

IJ

IJ

IJ

IJ

IJ
LJ

LJ

LJ

LJ

LJ

LJ

LJ
Z

IJ

IJ

IJ

IJ

IJ

IJ

IJ
4025

LJ

29

LJ

LJ

LJ

LJ

LJ

LJ

LJ

LJ

LJ

LJ

LJ

IJ

IJ

IJ

IJ

IJ
LJ

DWN

ISSUE OR REVISION

LJ

5460

IJ

IJ

IJ

IJ

IJ

IJ

IJ

DATE

CLIENT:-

3025

30

IJ

IJ

6000

REV. NO.

6800

DESIGN CONSULTANT :-

Design Group Engineering Consultants


31
32

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

UP

33
4115

5883

Q1

3790

6000

R1

6000

6000

S1

1835

28

1275

00

UP

1975

69

3325

26

1990

25

IJ

3835

2675

95
68

1021

IJ

LJ

6000

PROJECT:

NEW FACILITY BUILDING

U
6000

DRAWING TITLE :

GROUND FLOOR JOINTS FRAMING PLAN

PLINTH BEAM FRAMING PLAN


6000

3790

U1

2775

3225

X1

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 06

00

GENERAL NOTES :-

SCHEDULE OF FIRST FLOOR BEAMS

2L T8 AT 200 C/C

2L T10 AT 150 C/C

6+6 T16 SIDE FACE BARS

3-T20

3-T16

3-T20

3-T16

3-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

4+4 T12 SIDE FACE BARS

3-T20

3-T20

3-T20

3-T20

3-T20

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

+3-T25
3-T25
+3-T25
3-T25
+
3-T25

+3-T25
3-T25
+3-T25
3-T25
+
3-T25

2L T10 AT 125 C/C

2L T8 AT 150 C/C

2L T8 AT 125 C/C

3+3 T16 SIDE FACE BARS

4L T10 AT 150 C/C

4L T10 AT 200 C/C

4L 10 AT 150 C/C

3+3 T16 SIDE FACE BARS

3-T20

3-T20

2L T10 AT 150 C/C

--

--

2L T8 AT 150 C/C

600

3-T20

3-T20

3-T20

3-T20

2L T10 AT 200 C/C

2L T10 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

B106

250

600

3-T20

3-T20

3-T20

3-T20

3-T20

4L T8 AT 150 C/C

4L T10 AT 200 C/C

4L T10 AT 150 C/C

B107

250

600

3-T16

--

3-T16

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

250

600

3-T25

3-T25

3-T25

3-T25

3-T25

4L T10 AT 150 C/C

4L T8 AT 200 C/C

4L T8 AT 150 C/C

3-T25

3-T25

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

B110

250

600

3-T25

3-T20

3-T20

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

B111

400

600

3-T25

--

3-T25

3-T16

3-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

B111a

400

900

3-T25

3-T25

3-T25

3-T25

3-T25

4L T10 AT 150 C/C

4L T10 AT 200 C/C

4L 10 AT 150 C/C

B1

10

05

5
B1

47

80

05

B1

00

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

B1

05
60

B1

05

B1

00

B1
1

05

60

00

B1

05

B1

40

10

20

B1

05

05

B1
05

06

05

05
B1

DN
05
B1

10

B1

B1
B1

05
B1

05

B1
05

05

80
4

13

20

05

B1
05

B1
0

B1

B1

90

10

B11

B1

05

B1

10

B105

B111

B111a

23

B105

B109

B109

6000

B105
B105

B105

B109

B105

05

B109

B105

B1

B105

B105

22

B105

B105

B105

B113

B102

B113

B102

B113

B113

B102

2790

B1
12

LIFT

05

B110

B1

DN

62

B1

B1
10

02

C1

06

40

B1
B1

04

B1

B109

B109

B105

B110

05

06
B1

06
B1
06
B1

B1
02

2
20

04

24

B111a
B105

B111

B105

B105

B105

3835

B111

B109

26
B105

B110

B105

Z
VOID

B105

B105

B105

B106

B105

B105

05

REV. NO.

DATE

DWN

ISSUE OR REVISION

B110

CLIENT:-

B103
B103

B103

B105

B106

6000

B106

B105

1275

29

UP

30

B110

DESIGN CONSULTANT :-

B105

B105

B106

Design Group Engineering Consultants

5460

B105

3025

B106

6800

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

B110
B105

B105

B105

B105

B105

B105

B105

B105

B105

B105

B105

B105

3790

6000

6000

6000

6000
B105

R1

S1

UP
B105

B105

NEW FACILITY BUILDING


DRAWING TITLE :

U
6000
09

B1

FIRST FLOOR BEAMS FRAMING PLAN

B105
6000

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

14.06.2015

B105
3790

U1

FIRST FLOOR BEAM FRAMING PLAN

B109

Q1

PROJECT:

B109

DN
B105

B105

1835

5883

B105

B113

4115

B105

B105

B105

B105

B113

B105

33

31

B105

32

B105

4025

B1

B1

B106

B106

28

05

07

06

B111
B105

B1

05

B1

B1

B105

B105

27

B105

2675
00

69

3325

03

15

10

B106

B106

25

1975

B1

3
10

B106
B105

1021

03

95

68

DN

B1

05

06

06

B1
1
35

B1

B1

12

B1
12
B102

B113

B113

B105

B113

05

05

B1

B1

03

B1

B1

B1

05

B1

05
B1

05
B1

06

B1
02
04

B1

05

07

B1

B1
0

B1
07

B1
12

B1

05

B1
05

06

B1

25

B1

05
B1

73

2
04

04

UP

B105

B105

B1

10

(DO

32

07

10

B1

T
-OU
EA)
CUT
T AR
H
G
I
E HE
UBL

00

B1
1

B1

05

B1

45
29

B1

B1

12
B1

M2

05

B1
05

B1

21

B1

B1
05

B1

30

07

B1

53

B1
05

B1

53

00

21
08

20

B1

12

08

A1

05

B1

05
B1
B105

05
B1

03

05

30

12
B1
B1

01
B1

05

11

B1

30

07

B1

53

B1

B1

13

01

00

B1

B1

EQ

84

B1
0

5
B1
1

12
B1
B1
12

B1
12

B1
12

08

B1
12

05

05

B1

05

30

B1

B1
12
EQ

1
10

01
B1

00

04
B1

B1
12
B1
12

B1
12

08

B1
12
EQ

0
B1

15

20

.
RG

B1

B1

05

B1

B1

OF RA
ROSEP
L
EEFER
T
S E
(R

77

B1
12

05

B1

03

03

24

B1

19

03

TE

B1

B1

00
76

00
76

08

07

M1

04

05

00

B1

05

B1

B1

13

B1
08

B1

05

12

B1

B1

76

08

B1

05

08

B1

04

EQ
.

B1

B1

B1

5
10

05

UP

51
23

B1

EQ

B1
12

05

B1
12

B1
05
B1
04

B1

18

7
74

EQ

B1
12

05
B1

B1

B1
1

50
01

B1
05

30
00

05
04
B1

17

83

B1
0

B1

05

12

5
11

12

B1
0

22

05
B1

B1
04

15

16

B1

B1

50
59

SUPPORT REINFORCEMENT DESIGNATION

B1
08

B1

3352

08

12

B107

RIGHT
(R.H.S.)

08

B1

47
90

B1

B1
1

3000

14

BEAM

LEFT
(L.H.S.)

08

B107

B1

05

3000

B1

12

B107

12
13

B1

3000

RIGHT
(R.H.S.)

B107

B1

10

00

05

ID

B1

05

B1

B1

30

B1

VO

B1

12

05

50
5

B1
1

B107

11

60

B1
12

32
50

2L T8 AT 150 C/C

00

B1

B1

B1

B104

B113

2L T8 AT 200 C/C

2+2 T16 SIDE FACE BARS

B1
12

2L T8 AT 150 C/C

2L T8 AT 150 C/C

12

--

2L T8 AT 200 C/C

--

2L T8 AT 150 C/C

B1
0

2-T16

--

2-T16

--

B1
05

3-T25

1990

2-T16

3-T25

BEAM

450

3-T25

08

3100

200

750

B1

8. GRADE OF BLINDING CONC. SHALL BE- C15

F1

05

3100

B113

250

10

B107

B112

3+3 T16 SIDE FACE BARS

7. GRADE OF CONC. SHALL BE- C-35

05

00

B1

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

05

B1

3-T25

03

700

44

B1

250

41
77

8
B109

54

7
3

B108

B1

05

3-T20

60

B1

3-T20

05

05

250

600

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

B1

B1

B105a

300

3-T25

05

B1
0

3-T25

B1

05

1000

00

B1

350

60
B1
05

B104a

3-T25

05

06

3-T25

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

B
B1

B1

1000

90

350

57

50
00

B104

+3-T25
3-T25
+3-T25
3-T25
+
3-T25

B1
05

2L T10 AT 150 C/C

B1

3-T25

05

3-T25

B1

3-T25

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

05

3-T25

B1

6+6 T16 SIDE FACE BARS

05

2L T10 AT 150 C/C

2L T10 AT 200 C/C

B1
0

2L T10 AT 150 C/C

20
00

2-T16

57
90

2-T16

B1
0

700

3-T20

06

250

B103

RHS

B1

1100

B102

LHS

250

250

REMARKS.

RIGHT SIDE (L/3)

B1
0

3-T25

B101a

MIDDLE

06

1450

1450

LEFT SIDE (L/3)

50
00

2-T16

250

EXTRA AT CONTINUOUS SUPPORT

05

3-T20

B101

STRAIGHT

B1

STRAIGHT

DEPTH

STIRRUPS

50
00

CURTAIL

WIDTH

B105

TOP REINF.

BOTTOM STEEL

28
7

SIZE(mm)
TYPE

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

2775

JOB NUMBER:
DGC-08-14-169

3225

X1

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 07

00

GENERAL NOTES :1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE
STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

SCHEDULE OF FIRST FLOOR SLAB REINF.


TOP REINF.

SHORT SPAN
(B1)

LONG SPAN
(B2)

SHORT SPAN
(T1)

REMARKS.

LONG SPAN
(T2)

S1

200

T12 AT 150 C/C

T12 AT 150 C/C

T12 AT 150 C/C

T12 AT 150 C/C

S2

200

T12 AT 100 C/C

T10 AT 150 C/C

T12 AT 100 C/C

T10 AT 150 C/C

S3

200

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

S4

150

T10 AT 200 C/C

T10 AT 200 C/C

T10 AT 200 C/C

T10 AT 200 C/C

S5

150

T10 AT 150 C/C

T10 AT 200 C/C

T10 AT 150 C/C

T10 AT 200 C/C

S6

200

T12 AT 150 C/C

T10 AT 150 C/C

T12 AT 150 C/C

T10 AT 150 C/C

S7

150

T10 AT 150 C/C

T10 AT 150 C/C

T12 AT 150 C/C

T12 AT 150 C/C

1
20
00

(mm)

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

57

90

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

B
60

57
90

THICKNESS

00

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

3
S5

60

00

60

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

S3

50
00

BOTTOM REINF.
TYPE

00

S5

*-TOP STEEL AT CONTINUOUS SUPPORT OF BEAM SHALL BE OF HIGHER REINFORCEMENT ON EITHER SIDE SLABS AT THE CONTINUOUS SUPPORT BEAM
50
00

54
44

00

F
S5

47

80

7. GRADE OF CONC. SHALL BE- C-35


40

00

41

77

50
00

S3

8. GRADE OF BLINDING CONC. SHALL BE- C15

F1
20

00

G
30

00

S5
47

S3

90

00

32

S1

60

50

S1

3100

10

60

S5

28
73

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

S3

S1
50
5

3100

S5
VO

11

ID

S3

S1
S1

S3

3000

50
01

S1

S3

S1

UP

S1

S1

3352

13

14

S1
S1

24

77

S1

S1

15

51
23

EQ

32
53

M1

S1

S1

EQ

25

S1

19

A1

EQ

15

90

S6

S1

S1

EQ

S1
S2
S7

S1

13

20

84

15

S1
S1

S5
11

DR

35

S1

UP

S1

80
4

13

20

00
76

S3

S7

S2

S1

S3
S1

C1

20

S3

S1

S1

DN

LIFT

S3

S1

S1

S1

22
S4

S5

S5

S5

S5

S5

S4

S5

2790

21

E
F AT
O
R
RO EP
L S
E
E ER
ST EF
(R

S1

53

)
G.

S7

S1

S1

M2

S2

00
76

21

S2

(DO

73

S1

EQ
.
00

00

40

18

7
74

S3
T
-OU
EA)
CUT
T AR
H
G
I
E HE
UBL

30

S1

S1

S1

EQ

S1

00

62

17

83
12

30

22
0

S2

76

00

S1

15

16

41

30

S1

53

S5

30

5
59

S3

20

29
45

S1

DN

30
00

S1

3000

13

3000

S1

12

S1

S5

23
S3

S3

S3

S3

S1

6000

S2

S1

S1

24
S1

S3

26
S3

S3

1975

00

69

3325

4025

S3

S3

REV. NO.

DWN

ISSUE OR REVISION

6000

S3
S3

S3

UP

30

6800

S3

DN
S5

PROJECT:

UP

NEW FACILITY BUILDING

33
S5

5883

Q1

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

31

S3

4115

Design Group Engineering Consultants

5460

3025

DESIGN CONSULTANT :-

S3

32

DATE

CLIENT:-

1275

29

S3

VOID

1990

28

1835

27

S1

S3

25

3835

2675

95

68

1021

DN

3790

6000

R1

6000

6000

S1

6000

DRAWING TITLE :

U
6000
S3

FIRST FLOOR SLAB FRAMING PLAN

S3

FIRST FLOOR SLAB FRAMING PLAN


6000

3790

U1

2775

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

14.06.2015

JOB NUMBER:
DGC-08-14-169

3225

X1

DRAWN :

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 08

00

EXTRA AT CONTINUOUS SUPPORT

LEFT SIDE (L/3)

MIDDLE

RIGHT SIDE (L/3)

LHS

RHS

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

03

60

00

3-T16

3-T16

3-T16

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

B206

300

750

3-T20

3-T20

3-T20

3-T20

3-T20

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

---

2L T10 AT 150 C/C

--

2L T10 AT 200 C/C

2L T8 AT 150 C/C

2L T10 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

03
B2

5
47
80

E
00

03

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

60

B2

F
B2

03

40

B2

B2

05

00

F1

03

20

B2

03

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

00

30

00

B2
03

B2

50

05

3000

03
B2

01
B2

B2
03

05

B2
03

3100

50
57

8. GRADE OF BLINDING CONC. SHALL BE- C15

03

B2

50
01

B2
0

03
B2

11

B2

05

B2

03

B2
03

3000

B2

03

05

B2

15

90

B2
0
3

33

03

80

B2
0

06

B201

B203

07

B201

03

40

05

62

B2

B203

3
B2
0

B203

B201

B201

B201

22
2790

20

21

B201

B2

03

B201
B201

03

B2

B2
01

B201

B203

B201

LIFT

B203

B201

B201

B203

00

76

03

02

03
B2

11

13

C1

B2

84

20

15

B2
0

B2

07

B2

0
76

B2

03

B2

56

B2

B2

04

19

A1

B2

13
20

B2
0

B2
0

B2

B2
0

07

B2

B2
0

B2

03
06

B2

00

25

38

06

B2
0

03

53

03

76

B2

04
B2

M2

B2
B2

B2
03

B2

03

58

53
21

05

B201

18

M1

4
27

04

12

B2
0

01

73

B2

05

B2

17

32

83

03

B2

B2

16

00

23

B2

B2
0

42

58

30

51

5
11

14

05

07

00

B2

30

15

30

22

01

53

00

05

03

B2

30

5
59

B2

03
03

B2

B2
03

05

B2

77

B2
B2

29
45

20

01

13

B2
03

03

3352

14

24

B2

B2
0

3000

13

B2
03

00

12

90

B2

B2
03

32

60
00

B2

7. GRADE OF CONC. SHALL BE- C-35

47

03

3100

10

B2
0

41
77

3-T20

--

B201

B201

B201

23

6000

B201

B201

B204

B204

58

20

3835

B205

B201
B201

1275

REV. NO.

DWN

ISSUE OR REVISION

5460

B201

B201

B201

B205

B205
B201

B201

B201

B201

B201

B201

B201

B201

B201

B201

B201

B201

B201

3790

6000

6000

6000

6000
B202

Q1

R1

S1

DESIGN CONSULTANT :-

B201

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

B201

PROJECT:

6000

02

B2

B202

31

DN

1835

5883

B201

B201

4115

B201

B201

33

B201

B203

32

DATE

CLIENT:-

30

B201

29

B201

28

B201

27

26

1975

00
69

3325

25

24

B205

B201

B201

2675

95

B203

B203

B201

68

1021

05
B2

4025

--

3-T20

6000

3-T20

--

54
44

3025

500

2-T16

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

00

03

03

6800

200

750

60

B2

B2

1990

B207

300

05

01

600

03

B2

250

B2

B205

B206a

50
00

2L T8 AT 150 C/C

B2
0

2L T8 AT 200 C/C

B2

B2
03

2L T8 AT 150 C/C

2L T8 AT 150 C/C

50
00

3-T16

2L T8 AT 200 C/C

B2
03

3-T16

2L T8 AT 150 C/C

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

00

03

50
00

3-T20

3-T16

28
73

3-T16

B204

3-T16

3-T20

B203

3-T20

3-T16

B204

600

3-T20

30

250

600

60

B201

B204

250

B2

B201

B203

3-T20

B201

3-T20

B2
01

3-T20

B2

750

03

250

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

B2
03

B2
0

B2
01

B202

3-T16

B2

2-T16

B2
03

3-T20

B201

600

B201

250

B201

B201

B2
03

STRAIGHT

03

CURTAIL

B
B2

B2

STRAIGHT

REMARKS.

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

90

57

DEPTH

STIRRUPS

B2
03

TYPE
WIDTH

TOP REINF.

BOTTOM STEEL

57

90

SIZE(mm)

20
00

SCHEDULE OF SECOND FLOOR BEAMS

GENERAL NOTES :-

NEW FACILITY BUILDING


DRAWING TITLE :

SECOND FLOOR BEAMS FRAMING PLAN

B201
6000

B201
3790

U1

2775

SECOND FLOOR BEAMS FRAMING PLAN

3225

X1

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 09

00

200

T12 AT 100 C/C

T10 AT 150 C/C

T12 AT 100 C/C

T10 AT 150 C/C

S3

200

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 200 C/C

T10 AT 200 C/C

150

T10 AT 150 C/C

T10 AT 200 C/C

T10 AT 150 C/C

T10 AT 200 C/C

T12 AT 150 C/C

T10 AT 150 C/C

T12 AT 150 C/C

57

T10 AT 150 C/C

47

80

F
40

00

S3

F1
20

00

50
32

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

G
30

00

7. GRADE OF CONC. SHALL BE- C-35

47

90

S3

3100

8. GRADE OF BLINDING CONC. SHALL BE- C15

3100

50
57

10

00

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

60

S5

41
77

*-TOP STEEL AT CONTINUOUS SUPPORT OF BEAM SHALL BE OF HIGHER REINFORCEMENT ON EITHER SIDE SLABS AT THE CONTINUOUS SUPPORT BEAM

50
00

S3

S3

11

50
01

3000

S3

3000

S3

3000

13

30

00

12

S3
13

14

3352

20

24

77
30

50

59

00

15

30

22

00

S2
S3

30

51

15

00

23

16

41

S5

S2

17

32

73

83

12

18

M1

7
74

S6

58

53
21

S1

38

76

53

M2

00

S3

25

S1

S2

S2

15

90

20

19

S6

A1

80

13

33

S2

56

S1

84

20

15

40

0
60

62

200

E
54
44

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

00

S3

11

13

C1

76

LIFT

S3

S1

00

22
20
07

21

S4

S4

2790

S6

T10 AT 200 C/C

60

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

00

S3

S5

23
20

58

S3

S3

6000

S5

150

T10 AT 200 C/C

60

S3

68

1021

3835

2675

95

24

26

27

1975

00
69

3325

25

4025
6000

1275

29

REV. NO.

DWN

ISSUE OR REVISION

CLIENT:-

6800

5460

3025

30

31
DN

32

DATE

DESIGN CONSULTANT :-

Design Group Engineering Consultants

1990

28

33
S5
4115

5883

Q1

3790

6000

R1

6000

6000

S1

6000

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

1835

S4

T12 AT 150 C/C

S2

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

50
00

T12 AT 150 C/C

00

50
00

T10 AT 150 C/C

60

29
45

T10 AT 150 C/C

REMARKS.

LONG SPAN
(T2)

53

150

SHORT SPAN
(T1)

30

S1

LONG SPAN
(B2)

60
00

(mm)

SHORT SPAN
(B1)

90

90

TOP REINF.

28
73

THICKNESS

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

57

BOTTOM REINF.
TYPE

20
00

SCHEDULE OF SECOND FLOOR SLAB REINF.

GENERAL NOTES :-

PROJECT:

6000
S3

NEW FACILITY BUILDING

S3

DRAWING TITLE :

SECOND FLOOR SLAB FRAMING PLAN


6000

3790

U1

2775

SECOND FLOOR SLAB FRAMING PLAN

3225

X1

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 10

00

GENERAL NOTES :-

SCHEDULE OF ROOF FLOOR BEAMS

CURTAIL

STRAIGHT

600

3-T20

2-T16

3-T16

250

750

3-T20

3-T20

B303

250

600

3-T20

B304

250

600

B305

250

600

LHS

RHS

2-T16

2-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3-T20

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3-T16

3-T20

3-T16

3-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3-T20

3-T16

3-T20

3-T16

3-T16

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

3-T16

3-T16

3-T16

--

--

2L T8 AT 150 C/C

2L T8 AT 200 C/C

2L T8 AT 150 C/C

20
00

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

60

00

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

3
60

00

54

44

L
47
8

00

F
40

41
77

50
00

00

7. GRADE OF CONC. SHALL BE- C-35

F1
20

00

8. GRADE OF BLINDING CONC. SHALL BE- C15

G
30

00

32
50

47

90

60
00

3100

50
57

3100

RIGHT
(R.H.S.)

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

60

10

00

28
73

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

60

11
3000

01
50

3000

13

RIGHT
(R.H.S.)

3000
29

24

77
00

53

30

50

59

15

30

22

00

58

14

42

30

51
2

15

00

16

41

20

45

3352

14

SUPPORT REINFORCEMENT DESIGNATION

13

30

BEAM

LEFT
(L.H.S.)

30
00

12

17

32

73

83

12

18

M1

4
27

58

53
21

9
38

53
2

M2

00

15

90

76

19

13

20

80

33

56

00

62

LIFT

B301

B301

B301

B303

B303

B301

B301

B301

B301

B301

B301

B301

B302

07

B301

B301

20

21

B301

B303

B301

B301

B301

22
2790

00

76

B301

11

13

C1

B302

84

20

15

40

76

A1

23

6000

B301

B301

B304

B304

B304

B301
B303

B305

B303

24

00
69

3835

B301

3325

25

B301

B301

2675

95
68

1021

B304

58

20

26

1975

B305

B301

4025

B305

29

REV. NO.

1275

DATE

DWN

ISSUE OR REVISION

B301

B301

B301

CLIENT:-

B305

30
5460

B301

B301

B301

DESIGN CONSULTANT :-

B305

4115

5883

Q1

B301

B301

3790

6000

R1

B301

B301

B301

B301

B301

6000

6000

6000

S1

B301

B301

B301

B301

B301

Muscat (Oman) + Bangalore (India)


P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

31

B301

B301

B301

Design Group Engineering Consultants

PROJECT:

B301

NEW FACILITY BUILDING

1835

33

B301

B301

32

B301
B301

B301

28

B301

27

6000

B302

REMARKS.

RIGHT SIDE (L/3)

3025

250

MIDDLE

6800

B301

LEFT SIDE (L/3)

BEAM

DEPTH

90

57
90

STRAIGHT

WIDTH

STIRRUPS

EXTRA AT CONTINUOUS SUPPORT

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

57

50
00

TYPE

50
00

TOP REINF.

BOTTOM STEEL

1990

SIZE(mm)

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

DRAWING TITLE :

U
6000

ROOF FLOOR BEAM FRAMING PLAN

ROOF FLOOR BEAMS FRAMING PLAN


3790

6000

U1

3225

2775

X1

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 11

00

GENERAL NOTES :-

SHORT SPAN
(B1)

(mm)

90

LONG SPAN
(B2)

SHORT SPAN
(T1)

REMARKS.

LONG SPAN
(T2)

200

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

T10 AT 150 C/C

S2

150

T10 AT 150 C/C

T10 AT 200 C/C

T10 AT 150 C/C

T10 AT 200 C/C

00

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE


DRAWINGS ARE FROM UNFINISHED SURFACES.

3
60

00

50
00

S1

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS
TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

60

57
90

THICKNESS

2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN


DIMENSIONS TO BE FOLLOWED.

57

TOP REINF.

BOTTOM REINF.
TYPE

20
00

SCHEDULE OF ROOF FLOOR SLAB REINF.

1. THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE


STRICTLY CONFIDENTAIL AND IS FOR USE BY RESTRICTED
PERSONS ON THIS PROJECT ONLY. NO PERSON ASSOCIATED
WITH THIS PROJECT SHALL DIVUGLE THIS INFORMATION TO
ANY THIRD PERSON/PARTY IN ANY MANNER WHATSOEVER

*-TOP STEEL AT CONTINUOUS SUPPORT OF BEAM SHALL BE OF HIGHER REINFORCEMENT ON EITHER SIDE SLABS AT THE CONTINUOUS SUPPORT BEAM

44

50
00

54

28
73

47

80

6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE


BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
PRIOR TO THE CONSTRUCTION.

60

00

40

00

41
77

50
00

7. GRADE OF CONC. SHALL BE- C-35

F1
20
00

8. GRADE OF BLINDING CONC. SHALL BE- C15

G
30

00

32
50

47

90

60
00

3100
3100

50
57

10

00

60

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

11

50

01

3000
3000

3000

13

30
00

12

13
45

14

3352

20

29

24

77
30

50

00

15

16

41

30

22

00

14

58
9

42

30

51
23

15

30
53

59

00

17

32

73

83

12

18

M1

4
27

58

53
2

38
00

53

M2

25

15

90

76

20

19

A1

80

33

56

00

62

84

20

15

40

76

13

LIFT

11

13

C1

00
76

22
07

2790

20

21

S2

S2

23

S1

S1

6000

58

20

S1

3835

2675

95
68

1021

24

S1

26

27

1975

0
69

3325

25

4025

S1

REV. NO.

1275

29

DATE

DWN

ISSUE OR REVISION

6000

CLIENT:S1

3025

30
5460

DESIGN CONSULTANT :-

6800

S1

Design Group Engineering Consultants


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
Email: info@dgcon.com l website:www.dgcon.com.

31
32

1990

PROJECT:

S1

S2

33
4115

5883

Q1

3790

6000

R1

6000

6000

S1

6000

NEW FACILITY BUILDING

1835

28

DRAWING TITLE :

U
6000

ROOF FLOOR SLAB FRAMING PLAN

ROOF FLOOR SLAB FRAMING PLAN


3790

6000

U1

3225

2775

X1

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

14.06.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

S- 12

00

ref Z:\AMRC_Al Mabelah Residential Commercial\05-planning CAD\05_03_design planning\Strl\layout\xref\A1 Sheet.dwg

A. GENERAL :
1.

REFER TO SPECIFICATION DOCUMENTS AND RELEVANT DRAWINGS FOR DETAILED STRUCTURAL REQUIREMENTS.

2.

ALL STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL AND SERVICES DRAWINGS.
DISCREPANCIES, IF ANY, SHALL BE BROUGHT TO THE NOTICE OF THE ENGINEER BEFORE PROCEEDING WITH WORK ON SITE.

3.

ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS ARE IN METRES. DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS,
FOLLOW WRITTEN DIMENSIONS ONLY.

4.

SOIL BEARING CAPACITY OF SOIL IS CONSIDERED AS

8.

UNPAINTED EXPOSED SURFACES OF ANY CONCRETE STRUCTURE ABOVE GROUND SHALL BE TREATED WITH
TWO COATS OF OF SUNDEXOTE SP ANTI-CHLORIDES AND CARBONATION COATING OR SUNANDA'S OR
ANY OTHER APPROVED EQUIVALENT WITH A DFT OF 350 MICRONS OR EQUIVALENT.

9.

USE SUNANDA'S POLYALK CP 293+ OR EQUIVALENT AS CORROSSION INHIBITOR FOR ALL CONCRETE WORKS
AS AN ADMIXTURE AT 0.6 L/CU.M.

10.

5.

ALL TEMPORARY WORKS AND SECONDARY SUPPORT STRUCTURES ARE TO BE DESIGNED BY THE CONTRACTOR. THE DESIGN
SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW IN ACCORDANCE WITH THE SPECIFICATION.

6.

SLABS ON GRADE TO BE CAST IN PANELS OF NO GREATER THAN 4.0m x 8.0m AND WITH EXPANSION
JOINTS AT NO MORE THAN 4.0m SPACING.

12.

CURING OF CONCRETE

THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A SAFE WORKING ENVIRONMENT AT ALL TIMES DURING THE ENTIRE
CONSTRUCTION WORKS IN ACCORDANCE WITH LOCAL AUTHORITY REQUIREMENTS. THIS INCLUDES TEMPORARY STABILITY
OF THE BUILDING OR PARTS OF THE BUILDING.

7.

THE CONTRACTOR SHALL SUBMIT RECORD DRAWINGS OF AS BUILT WORKS FOR THE ENGINEER'S APPROVAL.
13.

B. EARTH WORK
1.

LAPS IN REINFORCEMENTS

10. FOR CANTILEVER BEAMS AND SLABS, UPWARD CAMBER OF 12mm SHOULD BE
GIVEN AT THE FREE END FOR EACH 3.0m SPAN.
11. IN CASE WHERE CANTILEVER LENGTH IS MORE THAN 2.5m, FORMWORKS IS TO BE RAISED
BY 12mm AT THE FREE END FOR EACH 3m SPAN.
12. IN CASE WHERE SECONDARY BEAM IS SUPPORTED ON A MAIN BEAM WITH TWO DIFFERENT

2. TOP REINFORCEMENT AT CONTINUOUS SUPPORTS.

13. IN CASE WHERE PLANTED COLUMN IS PROVIDED, REINFORCEMENT MUST BE EXTENDED OVER
60 DIA ALONG THE BEAM LENGTH, BEAM STIRRUPS MUST BE DOUBLED.

14.

GRADE OF CONCRETE
C40 - FOUNDATION, COLUMN, BEAM, SLAB, STAIR, CORE WALL ,

14. IN CASE OF RIB, DOWELS ARE TO BE LEFT AT THE TOP AND BOTTOM LEVELS OF THE RIB.
CONCRETING IS DONE ONLY AFTER THE FLOOR FORMWORK IS REMOVED.

D. FORM WORK
1.

2.

FORM WORK SHALL BE ERCTED TO THE TOLERANCES GIVEN IN:-BS:5975

ENGINEERING. PLINTH FILLING/GRADE FILLING SHALL BE DONE IN LAYERS OF 150MM THICKNESS

3.

FORM WORK FOR VARIOUS STRUCTURAL MEMBERS SHALL NOT BE REMOVED BEFORE THE EXPIRY OF
FOLLOWING PERIODS AFTER CASTING.

AND HAVE A NOMINAL MAXIMUM AGGREGATE SIZE OF 20mm. ABOVE GROUND FLOOR LEVEL, THE MINIMUM CEMENT CONTENT
SHALL BE 350kg/m3 WITH A MAXIMUM FREE WATER/CEMENT RATIO OF 0.42. CEMENT SHALL BE ORDINARY PORTLAND CEMENT,

CLOSED CELL, EXPANDED POLYETHYLENE FOAM (OR SIMILAR)


MAXIMUM JOINT SPACING TO BE 6.0m IN REINFORCED CONCRETE
PARAPET WALLS OR AS SHOWN ON THE DRAWINGS. OTHER
ELEMENTS TO BE AS PER DRAWINGS.

b. IN INTERNAL BLOCKWORK:
(JOINTS LOCATION AND SIZE AS
SPECIFIED ON DRAWINGS)
c. JOINT SEALANTS

FIBRE BOARD JOINT FILLER TO SPECIFICATION.


MAXIMUM JOINT SPACING TO BE 6.0m IN ALL MASONARY
ELEMENTS, OR AS PER DRAWINGS.
REFER TO SPECIFICATION FOR MATERIALS.

COVER TO REINFORCEMENT
EXTERNAL, BELOW GROUND AND TANKED
EXTERNAL, BELOW GROUND AND NOT TANKED
EXTERNAL ABOVE GROUND
INTERNAL BEAMS,WALLS AND COLUMNS

: 60mm
: 75mm
: 45mm
: 40mm

a. ALL EXTERNAL HORIZONTAL AND VERTICAL CORNERS OF SUBSTRUCTURE / SUPERSTRUCTURE RC ELEMENTS SHALL HAVE
20mm x 20mm CHAMFERS.
CONCRETE PROTECTION
a. ALL CONCRETE FACES IN CONTACT WITH SOIL BELOW THE GROUND SLAB LEVEL ARE TO BE PROTECTED BY 2 COATS OF BITUMINOUS
PAINT AND WRAPPED IN 1200 GAUGE POLYTHENE SHEETS, UNLESS NOTED OTHERWISE, TO THE APPROVAL OF THE ENGINEER.
ALL APPLICATIONS ARE TO BE CARRIED OUT STRICTLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
OR
b. ALL CONCRETE FACES IN CONTACT WITH SOIL INCLUDING 150mm ABOVE GROUND LEVEL AND TOP OF BLINDING CONC. SHALL BE TREATED
WITH SUNPOLYKOTE 293 OR SUNANDA'S OR ITS APPROVED EQUIVALENT STRICTLY EXECUTED AS PER THE MANUFACTURE'S

(c)BEAM SOFFITS (PROPS LEFT UNDER)


(i) SPANNING <4.5M
: 7 DAYS
(d)REMOVAL OF PROPS
UNDER SLABS :-

:-7 DAYS

4.5M

MENTIONED ON STRUCTURAL DRAWINGS.

H. DESIGN NOTES
1. DESIGN PARAMETERS AND DESIGN LOADS ADOPTED FOR
STRUCTURAL DESIGN ARE AS GIVEN IN DESIGN BASIS.

: 14 DAY

2.

6M
6M

MATERIALS OF CONSTRUCTION SHALL HAVE FOLLOWING STRENGTHS


(A) CONCRETE CHARACTERISTIC STRENGTH C40
MINIMUM CEMENT CONTENT
350 kg/m3

: 14DAY
: 21DAY

MAXIMUM WATER/ CEMENT RATIO

0.42

(B) HIGH YIELD STRENGTH DEFORMED BARS ......Fy 460


(C) CONCRETE BLOCKS' : MINIMUM CRUSHING STRENGTH = 7.5N/mm2
3.

NET SAFE BEARING CAPACITY IS ADOPTED AS PER SOIL REPORT

E. LINTELS
1.

a. IN REINFORCED CONCRETE:

:-3 DAYS

17. IN GENERAL, THE R.C. FLOOR SHUTTERING MUST NOT BE REMOVED EARLIER
THAN 15 DAYS AFTER CONCRETING. FOR CANTILEVER BEAMS, SHUTTERING IS ONLY
SHUTTERING IS ONLY REMOVED AFTER 21 DAYS OF CONCRETING UNLESS OTHERWISE

(PROPS UNDER THE CANTILEVER SLABS OR BEAMS (VIZ. CANOPIES, BALCONIES, SUNSHADE,ETC.) SHALL
BE REMOVED ONLY AFTER THE NECESSARY COUNTER WEIGHT STRUCTURE AS SHOWN IN DRAWINGS, HAS
BEEN ERECTED AND CURED.)

REINFORCEMENT:

EXPANSION JOINTS FILLER

(b)SLABS (PROPS LEFT UNDER)

(i) SPANNING <


(i) SPANNING >
-

BLINDING SHALL BE GRADE C20 WITH ASTM 1 OR OPC.


CONCRETE FOR GROUTING OF BLOCK WALL CAVITIES SHALL BE GRADE C20

CONCRETE BLOCKS SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTHS:

:-24TO48HOURS

16. A SLOPE OF 1% MUST BE PROVIDED IN THE SLABS OF BALCONY AND TERRACE.

(e)REMOVAL OF PROPS UNDER BEAMS &ARCHES :-

FREE WATER/CEMENT RATIO OF 0.43. (REFER SOIL INVESTIGATION REPORT FOR TYPE OF CEMENT)

(DEFORMED BARS TYPE-2)


HIGH YIELD STEEL IS INDICATED WITH PREFIX ' T ' ON DRAWINGS

(a) WALLS,COLUMNS&VERTICAL FACES OF STRUCTURAL MEMBERS.

(i) SPANNING >


-

OR ASTM TYPE I. BELOW GROUND FLOOR LEVEL, THE MINIMUM CEMENT CONTENT SHALL BE 380kg/m3 WITH A MAXIMUM

15. NO BOTTOM STEEL SPLICES ARE ALLOWED TO TAKE PLACE AT THE SPAN'S MIDDLE THIRD
(IF ANY). HOWEVER, TOP STEEL SPLICES ARE PROVIDED ONLY AT THE MIDDLE THIRD.

THE FORM WORK SHALL BE DESIGNED AND CONSTRUCTED TO BE ABLE TO CARRY THE DEAD
LOAD OF STRUCTURAL MEMBERS.

ANY UNPRECIDENTED ISSUES UNSEEN STRUCTURES(OLD EXISTING RETAINING WALLS, EXISTING FOOTINGS) WITHIN THE
SOIL ENCOUNTERED DURING EXCAVATION SHOULD BROUGHT TO NOTICE OF GEOTECHNICAL ENGINEER FOR PROPER SOIL

EXCEPT WHERE OTHERWISE NOTED, CONCRETE SHALL BE OF GRADE C40/20 I.E. IT SHALL HAVE A CHARACTERISTIC STRENGTH,

6.

9. FOR SLABS AND BEAMS AN UPWARD CAMBER OF 7mm SHALL BE GIVEN IN THE SHUTTERING
AT MID SPAN FOR EACH 5.00m SPAN, OR AS PER INTERNATIONAL CODES WHICHEVER IS LARGER.

b. NO LAPS SHALL BE ALLOWED IN


1.COLUMN FOOTINGS.

CONCRETE

5.

MINIMUM PROVIDED OF CURING : 7 DAYS.

SHALL BE LAPPED NEAR THE MID SPAN.

C. REINFORCED CONCRETE CONSTRUCTION

4.

8. IN SLABS, TOP REINFORCEMENTS MUST BE ADEQUATELY SUPPORTED BY STEEL CHAIRS,


TO ENSURE ITS RIGHT POSITION. BOTTOM REINFORCEMENTS SHALL BE SUPPORTED BY SPACER BLOCKS.

4. TOP REINFORCEMENT OF CANTILEVERS.

WHEREVER THE FINISHED GRADE LEVELS (F.G.L.) ARE BELOW THE NATURAL GROUND LEVELS (N.G.L.) FOUNDING DEPTHS
SHALL BE FROM THE FINISHED GRADE LEVELS.

3.

THEY SHOULD BE KEPT CONTINUOUSLY WET BY FREQUENT SPRAYING OF WATER.


CURING SHOULD START IMMEDIATELY AFTER REMOVAL OF FORMWORK.

AS MINIMUM SPECIFIED DEPTH IN THE DRAWING UNLESS OTHERWISE NOTED.

MATERIAL FOR PLINTH AND GRADE FILLING SHALL BE NON SWELLING/NON EXPANSIVE TYPE OF MURRUM OR STABILIZED MATERIAL
APPROVED BY ENGINEER PRIOR TO PLINTH FILLING/GRADE FILLING. TOP SOIL UP TO NECESSARY DEPTH SHALL BE CLEARED
OF ALL VEGETATION. AND WELL COMPACTED TO 98% PROCTOR DENSITY.

2.

7. IN SLABS AND BEAMS, WHERE NO BENT BARS ARE INDICATED ON THE STRUCTURAL
DRAWINGS, TOP REINFORCEMENT MUST BE EXTENDED TO 0.25 THE LENGTH OF THE ADJACENT SPAN.

DEPTHS, STEEL REINFORCEMENTS MUST BE PROVIDED ALL OVER THE MAIN BEAM DEPTH.

4.

1.

EXPOSED CONCRETE SURFACES SHOULD BE COVERED WITH DAMP ABSORBENT


MATERIAL AFTER PLACING CONCRETE.

3. BOTTOM REINFORCEMENT AT MID SPAN.

ANTITERMITE TREATMENT TO FOUNDATIONS AND PLINTH FILLING SHALL CONFORM TO IS:6313 CODE OF PRACTICE.

6.

6. IN CASES WHERE BEAM DEPTH, IS MORE THAN 60cm, 12mm DIA WEB BARS MUST BE PROVIDED
EVERY 20cm ALONG THE BEAM DEPTH ON BOTH FACE, UNLESS OTHERWISE MENTIONED
ON STRUCTURAL DRAWINGS.

FOUNDING LEVEL FOR ALL TRENCHES AND PITS SHALL BE MAINTAINED AT ONE UNIFORM LEVEL IN A PARTICULAR BUILDING

3.

5.

5. IN CASES WHERE INVERTED BEAM IS INDICATED ON THE STRUCTURAL DRAWINGS, WING


STIRRUPS MUST BE PROVIDED.

a. IN BEAM BOTTOM REINFORCEMENT SHALL BE LAPPED AT THE SUPPORT AND TOP REINFORCEMENT

WHEN EXCAVATING TO FOUNDATION LEVEL CARE SHOULD BE TAKEN NOT TO DISTURB THE UNDERLYING MATERIAL.
ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND ANY SOFT SPOTS REMOVED AND REPLACED WITH
GRANULAR FILL, WHICH SHALL BE WELL COMPACTED BEFORE CONSTRUCTION PROCEEDS. IN ROCK IRREGULARITIES
AND EXCAVATED SOFT SPOTS SHALL BE FILLED WITH CONCRETE GRADE C20/20. EXCAVATION SHALL AT ALL TIMES
BE CARRIED OUT IN DRY CONDITIONS. ALL FORMATION SURFACES SHALL BE PROOF-ROLLED PRIOR TO BEING COVERED OVER.

2.

4. TOP STEEL REINFORCEMENTS OF THE CANTILEVER (SLABS OR BEAMS) MUST BE EXTENDED


INTO THE ADJACENT SPAN, ATLEAST TWICE THE CANTILEVER LENGTH (ON TOP OF THE ADJACENT SPAN)

ALL HORIZONTAL SURFACES IN CONTACT WITH THE GROUND TO HAVE MINIMUM 50mm BLINDING.

11.
(TO BE CONFIRMED WITH SOIL INVESTIGATION REPORT)

3. IN SIMPLY SUPPORTED SLABS, AS WELL AS IN THE BEGINNING AND END OF CONTINUOUS


SLABS, BENDING OF REINFIRCEMENT IS DONE AT DISTANCE 0.20 SPAN FROM FACE OF SUPPORT.

TYPICAL LINTEL DETAILS ARE GIVEN IN STANDARD DETAILS DRAWING SHEET AND ACCOMPANYNG TABLE.

F. BLOCK WORK
1.

ALL BLOCKWORK UP TO PLINTH LEVEL SHALL BE OF SOLID BLOCKS .

2.

BRICK MASONRY SHALL BE CONSTRUCTED IN CEMENT MORTAR 1:5 (TYPE M2) UNLESS SPECIFIED OTHERWISE.

3. MINIMUM THREE BRICKS SHALL BE SELECTED AT RANDOM FROM EACH LOT AND SHALL BE TESTED FOR
CRUSHING STRENGTH AND WATER ABSORPTION & TEST RESULTS SHALL BE IN CONFORMITY WITH
RELEVANT STANDARDS FOR TESTING.
4. ALL BLOCKWORK USED IS TO COMPLY WITH THE REQUIREMENTS OF INTERNATIONAL CODES WITH A MINIMUM
COMPRESSIVE STRENGTH OF 7.5 N/mm2 FOR HOLLOW BLOCKS AND 12 N/mm2 FOR SOLID BLOCKS.
5. MORTAR FOR MASONRY SHALL CONFORM TO IS:2250.
6. WHEREVER HOLLOW BLOCKS ARE FILLED, CONCRETE GRADE O.P.C. 20/O.P.C 15 TO BE USED FOR WORKS
BELOW/ABOVE PLINTH LEVEL RESPECTIVELY.

ABBREVIATIONS
SSL

SRUCTURAL SLAB LEVEL

EGL

EXISTING GROUND LEVEL

FGL

FINISHED GROUND LEVEL

FFL

FINISHED FLOOR LEVEL

TOC

TOP OF CONCRETE

TOB

TOP OF BEAM

TOP
SOB

TOP OF PARAPET
SOFFIT OF BEAM

UNO

UNLESS NOTED OTHERWISE

N.T.S.

NOT TO SCALE

7. BLOCKWORK SHALL BE SECURED TO CONCRETE FRAME USING SCREW FIXED OR SHOT FIRED APPROVED
GALVANIZED METAL TIES FIXED TO TO COLUMNS AND UNDERSIDE OF FIRED APPROVED GALVANIZED
METAL TIES FIXED TO COLUMNS

LVL

LEVEL

THK.
CJ

THICK
CONSTRUCTION JOINT

8. UNLESS OTHERWISE SPECIFICALLY MENTIONED ALL BLOCK WORKS FOR PARAPETS SHALL BE FILLED WITH
CONCRETE AND T12-200 STEEL BLOCK WORK, FOR OTHER AREAS SHALL NOT BE FILLED WITH CONCRETE

EF

EACH FACE

MJ
EJ
IJ

MOVEMENT JOINT
EXPANSION JOINT
ISOLATION JOINT

SL

STRUCTURAL LEVEL

R/F

REINFORCEMENT

SC

STUB COLUMN

FC

FLOATING COLUMN

T
TW

TOR STEEL BAR DIAMETER


THICKNESS OF WALL

9. ALL MASONRY JOINTS SHALL BE RAKED TO A DEPTH OF 6mm TO ENSURE EFFECTIVE BOND WITH PLASTER.
10. ALL PARTITION (HALF BRICK THICK) WALLS LENGTH UP TO 6.0M SHALL BE PROVIDED WITH REINFORCEMENT
AT EVERY FOURTH COURSE WITH 2.NOS OF MIN. 6mm DIA BARS, HALF THE MORTAR SHALL BE LAID
LAID FIRST AND OTHER HALF LAID AFTER THE REINFORCEMENT IS PLACED INTO THE POSITION.
11. A REINFORCED CONCRETE BOND COLUMN HAVING A WIDTH OF 20cm AND DEPTH EQUAL TO THE WIDTH OF
THE WALL REINFORCED WITH 4T12 AND T8-200 STIRRUPS SHALL BE PROVIDED IN ALL BLOCKWORK
WALLS AT A SPACING OF 6m. THIS COLUMN MUST BE ANCHORED IN UPPER AND LOWER SLABS.
12. A REINFORCED CONCRETE BOND BEAM HAVING A DEPTH OF 20cm AND WIDTH EQUAL TO THE WIDTH OF THE

HATCH PATTERN
CONCRETE IN SECTION
HATCH PATTERN - SOLID

NOTE:
CONCRETE IN SECTION SHOWING
REINFORCEMENT IS NOT TO BE HATCHED
BLOCKWORK
HATCH PATTERN - ANSI32

STEEL HATCH
HATCH PATTERN - STEEL

BLINDING / SCREED
HATCH PATTERN - AR-SAND

COMPACTED SUB-BASE
HATCH PATTERN - AR-PARQ1

EARTH
HATCH PATTERN - EARTH

FILLER BOARD (IN SECTION)


HATCH PATTERN - NET3

STANDARD SYMBOLS
LEVELS ON SECTIONS / ELEVATIONS (METRES)
LEVELS ON PLANS / GA'S (METRES)
S-

DWN

ISSUE OR REVISION

CLIENT:-

EXISTING REINFORCED CONCRETE COLUMN


NEW REINFORCED CONCRETE COLUMN

AND T8-200 STIRRUPS SHALL BE PROVIDED AT MIDDLE HEIGHT OF THE BLOCK WALLS WITH CLEAR HEIGHTS

REINFORCED CONCRETE COLUMN TERMINATING

13. THE GROUT MORTER USED FOR ROTATING AND RECIPRCCATING EQUIPMENT AND BASE WITH SHEAR KEYS
SHALL BE NON-SHRINK READY MIX EPOXY BASE GROUT WITH SUNANDA'S SUNEPOXY 300 OR ANY OTHER

DATE

SLAB PANEL TYPE

WALL REINFORCED WITH 4T12 AND T8-200 STIRRUPS SHALL BE PROVIDED AT MIDDLE HEIGHT 4T12
EXCEEDING 3.50m. THIS BEAM MUST BE ANCHORED IN ADJACENT COLUMNS/WALLS.

REV. NO.

DESIGN CONSULTANT :-

OPENING IN FLOOR OR WALL


DENOTES SET DOWN TO TOP OF STRUCTURAL SLAB LEVEL

RECOMMENDATIONS/INSTRUCTION/PRODUCT GUIDE.

G. SLAB AND BEAMS


6A.

7.

STEEL PROTECTION

PROJECT:

ALL EXPOSED REINFORCEMENT STEEL & STRUCTURAL STEEL HAVE TO BE PAINTED


PAINTED WITH EPOXY ANTI-CORROSIVE PAINT

1. KITCHEN AND TOILET SLABS SHALL BE PREPARED WITH 4mm THICK APPROVED
TORCH APPLIED MEMBRANE WATER PROOFING

SPACERS / COVER BLOCKS AND CHAIRS

2. IN CONTINUOUS SLABS, HALF OF THE BOTTOM STEEL REINFORCEMENTS SHALL STOP AT


0.20 OF THE SPAN FROM THE FACE OF EACH SUPPORT IN BOTH DIRECTIONS,
UNLESS OTHERWISE MENTIONED ON STRUCTURAL DRAWINGS.

SPACERS OR COVER BLOCKS, TIES AND CHAIRS SHOULD BE PROVIDED TO COMPLY WITH STANDARD SHOULD BE PROVIDED TO COMPLY

NEW FACILITY BUILDING


DRAWING TITLE :

WITH STANDARD PROVISIONS GIVEN IN SECTIONS 3,4,5,6 AND 7 OF CONCRETE SOCIETY REPORT CS 101, NOVEMBER 1989.CONCRETE

GENERAL NOTES

SOCIETY REPORT CS 101, NOVEMBER 1989. COVER BLOCKS SHOULD BE OF THE SAME CONSTITUENT OF THE CONCRETE AND
THE TIE WIRE SHOULD BE OF 16 GAUGE BLOCK ANNEALED WIRE.

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

18.05.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

GN-01

00

BEAM SECTION (REF. 1)


TYP. C/S DETAIL OF BEAM WITH

BEAM SECTION (REF. 2)

SIDE BARS FOR BEAMS


DEEPER THAN 600

TWO LAYER REINFORCEMENT AT TOP & BOTTOM


TYPICAL CONTINUOUS BEAM

TYPICAL SINGLE SPAN BEAM

TYPICAL CANTILIVER BEAM

TYP. DETAILS OF REINFORCEMENT OF


ADJOINING BEAMS OF DIFFERENT DEPTH

SPECIFIC NOTES:

DETAIL AT CHANGE OF COLUMN SECTION


TYPE - 1

DETAIL AT CHANGE OF COLUMN SECTION

FLOATING COLUMN

TYPE - 2

COLUMN SUPPORTED ON BEAM

SECTION A-A

SECTION B-B
SECTION C-C

TYPICAL LINTEL FOR 100 -150 Thk. WALLS

TYPICAL LINTEL FOR 190 Thk. WALLS


TYPICAL LINTEL FOR 190 Thk. WALLS

CONNECTION SCHEDULE FOR LINTELS

SCHEDULE FOR LINTELS


190 THK WALLS ( L > 1500)
REV. NO.

DATE

DWN

ISSUE OR REVISION

CLIENT:-

SCHEDULE FOR LINTELS


300- 450 THK WALLS

SECTION E-E

DESIGN CONSULTANT :-

TYPICAL LINTEL FOR 300-450 THK WALLS


SECTION D-D

TYPICAL COLUMN ELEVATION


(STARTING FROM RAFT FOUNDATION)

LINTEL CONNECTION DETAILS


(WHERE WALL BEARING IS LESS
THAN SHOWN IN TYPICAL DETAIL)

SECTION D-D

PROJECT:

LINTEL DETAILS

NEW FACILITY BUILDING

(FOR NON-LOAD BEARING BLOCK WALLS)

DRAWING TITLE :

STANDARD DETAILS
(COLUMN & BEAMS)
DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

11.06.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

SD-01

00

CONTINUOUS
SUPPORT

CONTINUOUS
SUPPORT

DISCONTINUOUS
SUPPORT

DISCONTINUOUS
SUPPORT

L1

L2

L3

OPENING < 150mm

L4

NOTE :
TYPICAL SECTION OF FLOOR SLAB

200mm

NOTES:

LAP

L1

L2

L3

L4

DETAIL AT CHANGE IN THICKNESS


NOTE :
OPENING - 150mm to 450mm

SECTION OF FLOOR SLAB > 200mm

L
Length of `U' = L/5

Length of `U' = L/5

L/2

OPENING - 450mm to 900mm

CANTILEVER SLAB

SECTION OF SINGLE SPAN SLAB

REV. NO.

DATE

DWN

ISSUE OR REVISION

CLIENT:-

DESIGN CONSULTANT :-

PROJECT:

NEW FACILITY BUILDING


DRAWING TITLE :

STANDARD DETAILS
(SLAB & OPENINGS)
DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

11.06.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:20

SHEET:

A1

DRAWING NUMBER:

REVISION:

SD-02

00

15

15 CONTROL JOINT

WALL HEAD DETAIL

TYPICAL MOVEMENT JOINT DETAIL

CAVITY WALL MOVEMENT JOINT DETAIL

50 200

150
25

DETAIL AT INTERFACE
WITH CONCRETE FRAME

600 EXTENT OF

190
190/240

195 (MIN.)

PART ELEVATION

300

SECTION 1-1

400 Max.

150

TYPICAL DETAIL AT LINTEL

REV. NO.

DWN

ISSUE OR REVISION

CLIENT:-

190

300

DATE

DESIGN CONSULTANT :-

PROJECT:

NEW FACILITY BUILDING


DRAWING TITLE :

STANDARD DETAILS
(BLOCK WALL)

90 BLOCK WORK AT TOILETS

DRAWN :

DESIGN :

CHKD :

APPR :

DATE:

M.S.

CH.

P.M.

D.R.K.

11.06.2015

JOB NUMBER:
DGC-08-14-169

SCALE:
1:200

SHEET:

A1

DRAWING NUMBER:

REVISION:

SD-03

00