Instruction of tap calculation for SU transformer used with Novomet VSD
Instruction of tap calculation
for step-up transformer used with Novomet VSD
Innovate your production with Novomet!
www. novomet.ru/eng
Instruction of tap calculation for SU transformer used with Novomet VSD
INSTRUCTION OF TAP CALCULATION
FOR STEP-UP TRANSFORMER USED WITH NOVOMET VSD. This instruction includes equations of tap calculation for SU transformer taking into account work at maximum operating frequency, considering voltage losses in cable and output sine-wave filter. 1. Calculation of basic voltage of motor is done for maximum operating frequency. Maximum operating frequency shall not exceed maximum frequency of ESP system (to be checked in ESP system passport). Fmax operation Umotor nominal Ubasic = Fnom Umotor nominal nominal voltage of PMM or AM, V; F max operating maximum determined operating frequency, Hz; Ubasic basic voltage of PMM or AM, V; Fnom nominal operating frequency of PMM or AM, Hz; For Asynchronous motor: 50 Hz 3000 rpm For PMM: 100 Hz 3000 rpm 200 Hz 6000 rpm 2. Calculation of losses in cable:
38.7 Imotor nominal Lcable line
Scable line 1000 U cable line losses in cable line, V 38.7 temperature factor Imotor nominal nominal current of PMM or AM, A Lcable line cable line length, m Scable line cross section of cable line conductor, mm2 Ucable line =
Innovate your production with Novomet!
www. novomet.ru/eng
Instruction of tap calculation for SU transformer used with Novomet VSD
3. Calculation of transformation ratio for SU transformer: Ubasic + Ucable line Ktr1 = 360 K tr1 transformation ratio for SU transformer 360 output voltage of VSD based on U/F characteristic, V 4. Calculation of losses in output sine-wave filter:
Uf = 2 Fmax operLfImotor nominalKtr0.01
U f voltage losses in output sine-wave filter, V Lf inductance of output sine-wave filter, mH 5. Calculation of corrected transformation ratio of SU transformer (taking into account voltage losses at output sine-wave filter):
Ubasic Ucable line
360 Uf
Ktr2 = Ktr2 corrected transformation ratio
6. Calculation of tap of SU transformer for supply voltage 380 V:
Utap = 380 Ktr2
7. Calculation of tap of SU transformer for supply voltage 480 V: 8. Utap = 480 Ktr2 8. SU transformer rating selection based on power required: