REPORTE DE INSPECCIN ULTRASNICA

ULTRASONIC INSPECTION REPORT

Repor N: AH-UT-CI-001-04

Custormer:
Project:

3
2
1

Weld identification:
Material Thickness:
Weld joint AWS:
Welding process:
Quality
requerimentssection N:
Remarks:

1/8"

Len gth (mm)

Angular distance
(sound path)

----

---

----

---

---

----

----

AWS D1.1 2000


table 6.2

Remarks

From X

From Y

Discontinuity evaluation

Indication
rating

Attenuation
rating

From face

70

Reference
level

Transductor angle

----

Indication level

Indication number

--------

Discontinuity

Leg

Line number

Decibels

GyM
Demolicion y
Reubicacion de
Facilidades
Probeta PQR-002
11 mm
A tope, calificada
SMAW

Depth from A
surface

1/8"

60

FORM AH-UT

----

----

----

-----

-----

Distance

Soldadura sin indicaciones relevantes, soldadura ACEPTABLE de acuerdo al codigo de acero estructural AWS D1.1-2000
Seccion IV tabla 6.2

We the undersigned, certify that the statements in this are that the were prepared and tested in accordance
With the requirements of section 6, Part F of ANSI/AWS D1.1 (2000) Structural Welding Code Steel
Test date:

18-Oct-2004

Manufacturer or Contractor:

Inspected by:

Omar Pino

Authorized: