SMARTFIT

BOILER JUNCTION BOX


42009699-001
FEATURES

Simplified wiring.

One wire per terminal.

Cable clamps.

Strong fire retardant ABS box.

Designed to comply with BS3955 and


its partial replacement BS EN 60730
and BS EN 61058.

APPLICATION
The Boiler Junction Box allows simplified wiring and IEE
compliance when connecting mains, boiler and pump to the
system. When the mains, boiler and pump are located a
considerable distance from the Base Unit, it allows either two
twin and earth cables or a single three core and earth cable to
be run from the boiler junction box to the Base Unit. This reduces
the number of cable runs required and also the potential for
errors to be introduced in the system wiring.

1.5

BOILER JUNCTION BOX


Installation

Specification

The location should be convenient for


installation components wiring and be
readily accessible.

BOILER JUNCTION BOX


Number of Terminals
Nominal Terminal Capacity
Maximum Current Terms
Maximum Current PCB
Cable Clamp Capacity

If fitted on a wall, the box may be


mounted either way up to allow for top or
bottom cable entry; the lid is reversible
on the base.
All information for the wiring is provided
on a label in the lid.
An optional sub base adaptor is available
for mini trunking, which comes with full
installation instructions.

Ordering Specification
42009699-001
Boiler Junction Box
42005749-001
Mini trunking sub base adaptor complete
with sub base to Boiler Junction Box and
fixing screws.

Dimensions

A
101

B
30

C
170

D
106

E
93

F
185

: 17
: 2 x 1.5mm2
: 10 amp 230V 50Hz
: 5 amp 230V 50Hz
: 4 x 2.5mm2 twin and E
: (max) per clamp (2 off)
Ambient Temperature Rating : 10C to 90C
Fixing
: 3 fixing holes in base for
: No. 8 woodscrews
MINI TRUNKING SUB BASE ADAPTOR
Mini Trunking Breakouts
: 13 breakouts distributed around the four
: sides of the adaptor
Cable Clamp Capacity
: 4 x 2.5mm2 twin and E (max) per clamp
: (2 off) from Boiler Junction Box
Fixing
: 3 fixing holes in base for No. 8 woodscrews.
: 3 off 4BA screws provided to fit adaptor to
: Boiler Junction Box
EC Directive
: Conforms to 89/336/EEC