RCM ACI-Builder Ver:
Design of Flexure According to ACI318M-11
(CALCULATE EQUIVALENT MOMENT DUE TO PROVIDED AREA OF STEEL
Tenslon-Controled Section
Sections aretenson-= {beta = 0.85-0.05[(Fc-28)/7]} >= 0.65, then beta = 0.850, Equivalent depth factor
Yimor =beta*Ct= 302 mm Equivalent compressiveblod eth
-Asmax(singly) = {[0.85*Fc*B*Ymax]/fy} = 1314.05 mm2 ‘Maximum area of steel for singly reinforced section
«Mur(singly) = phi*(0.85°Fc*B*Ymax*[dt-(¥max/2)]) = 48.22 kNm_ ‘Maximum resistance moment for singly reinforced section
Section works as 2 Sngly Reinforced Section because of:
Provided areaof steel As(total)is lesserthanthe maximumarea of steelfor Singly Reinforced Section (Asmax)
Astata) = 37699 mma 420 MPa then Asmin = max of {0.0018%(420/fy)"8"H/2 , 0.0014*B*H/Zp-b@plazedrud each face of slab
“fultotal)= 3769912 > Avmin = 90.72mm2 OK
Catculate equivalent moment
Y= {Asttotal)*fy / (0.85*FB)} Equivalent compressive block depth
«Mu = {phi"0.85*Fc*B"¥"(d-¥/2)} = 15.70 kNm Equivalent moment for provided area of steel
RCH AC-Builder (Reinforced Concrete Members ACI-Builder) Developed by: Eng. Hussein Rida