Академический Документы
Профессиональный Документы
Культура Документы
RANTY
AR
W
years
s
ct
on u
if m p r o d
Gesamtkatalog EN 2015_Stilvorlage LK FrutigerOT_2010 DE_GB.qxd 17.11.14 12:50 Seite 3
Safety technology from ifm
The optimum solution for every application
2
Inductive
Fail-safe inductive sensors For industrial applications 4- 5
Light curtains
Light grids
Safety light curtains For industrial applications
Safety light grids For hygienic applications 6- 7
Safety at Work
AS-Interface
AS-Interface
Safety at Work
For industrial applications 8- 9
monitoring
Speed
Safe speed monitoring For industrial applications 10 - 11
SmartPLC
Safety control system
SmartPLC
For industrial applications 12 - 13
ecomatmobile
PL
Introduction
Introduction
Safety
SIL
Machinery Directive
16 - 19
Safety level
3
For industrial
applications
Direct detection:
Switches when metal is present,
no special target needed
Flexible:
M12, M18, M30 and rectangular
housings.
Safety compliant:
Conformity to IEC 62061 /
ISO 13849 and IEC 60947-5-3
safety standards as certified by
the German TÜV.
Evaluation:
Evaluation and diagnosis to SIL 3 /
PL e via safety relays or easily via
AS-i Safety at Work.
Complete solution
ifm provides the appropriate accessories
for every application – from fixing
components and protective brackets Protective housing
to evaluation units. for fail-safe
inductive sensors
Type E12396
go to:
p ro d u c t selection esafety
For inductiv
.com / gb /
www.ifm
4
Fail-safe inductive sensors
Inductive
to safety evaluation units, e.g. to safety
relays, programmable logic modules or
safe controllers. The G150xS safety relay
allows the series connection of up to
10 sensors with clocked output.
Light curtains
The safety sensors are simply connected
Light grids
via standard M12 connectors of the
ecolink series.
Safety at Work
AS-Interface
monitoring
Speed
Safety on escalators
Safety sensors on escalators are used
to detect a missing step. The safety
Fail-safe inductive monitor connected via AS-i triggers
sensor a safe state of the escalator in case of
an error. Compared to the mechanical
roller lever switches which are often SmartPLC
used the sensors work without contact
and thus without mechanical wear.
Type GMxxxS
ecomatmobile
the sensor.
Safety
Type G1502S
5
For industrial For hygienic areas
applications and viscous media
Compact:
Type OY with very small housing
dimensions starting with
28 x 30 mm. Can be installed
without dead band.
Long range:
Ranges selectable on the unit.
Light curtains up to 20 m, light
grids up to 60 m.
Easy connection:
Tried-and-tested M12 connection.
The configuration is made via the
pin connection.
Flexible solutions:
Standard through-beam systems –
transmitter / receiver or active /
passive systems with only one
connection. Transmitter and
receiver in one housing, passive
reflector system as counterpart.
n go to:
o r p ro d u ct selectio tcurtain
F ligh
w w .i fm .com / gb / lightgrid
Blanking w .com / gb /
www.ifm
Blanking suppresses individual light
beams or up to three neighbouring
light beams. Floating blanking even
allows different beams to be suppressed.
6
Safety light curtains and
safety light grids
Compact, small and reliable
In all applications with dangerous areas
requiring finger, hand and operator
protection, the small and powerful safety
light curtains and light grids from ifm are
the first choice.
The main differences of the versions of
the OY series are the resolution and the
Inductive
protected area height. Various functions
such as range and restart are configured
directly on the unit, a PC is not required.
A t-slot on the back allows simple and
reliable mounting using the supplied
Light curtains
mounting material. The various accessories
Light grids
make low-cost and efficient use easier.
Safety at Work
AS-Interface
monitoring
Speed
Muting Safety light curtain
The temporary automatic muting Resolution 14 to 40 mm
function allows feeding of products to Protected area height 160 up to 1210 mm
the dangerous area.
Type OYxxxS
SmartPLC
Muting relay
Type G2001S
ecomatmobile
160 to 910 mm
IP 69K with integrated heating
Safety
Type OY4xxS
7
For industrial
applications
Simple:
Modular structure and flexible
connection technology ensure
easy integration into the
AS-Interface system.
Cost-optimised:
A two-wire flat cable transmits
safe and non-safe data as well
as power. Complex parallel
wiring is not necessary.
Flexible:
Can be extended easily and at
low cost at any time.
Reliable:
The sophisticated AS-i technology
ensures high reliability and
machine uptime.
Safety stop
AS-i E-STOP Illuminated E-STOP with integrated
AS-i connection. Fool-proof to
EN ISO 13850. Pull to reset.
Type AC010S
Accessory
Protective collar
Type E7004S
Safety inputs
Safe AS-i input module for mechanical
contacts. The AS-i flat cable is directly
connectable, orientation is possible in Safe AS-i input
three directions. module
Type AC505S
8
AS-Interface Safety at Work
Inductive
safety-related components can be used
Modbus-TCP
in one system. Only a safety monitor and
safe AS-i slaves are added to the existing
Profibus
AS-i system with standard components Profinet
such as AS-i master, AS-i power supply, EtherNet/IP
AS-i slaves etc. Therefore a mixture of
Light curtains
Light grids
safe and non-safe AS-i slaves is possible
without any problems.
Safety at Work
AS-Interface
In the field:
E-STOP with AS-i
Safety at Work
connection.
monitoring
Speed
In the control cabinet
The central safety components in the
control cabinet: AS-i master and AS-i
safety monitor. AS-i
safety monitor
SmartPLC
Type AC041S
ecomatmobile
Safe access
Safe door switch with mechanical
securing function and integrated AS-i
connection. Rotatable actuating head Safe AS-i door
made of metal. Mechanical release switch
on the front.
Introduction
Safety
Type AC90xS
to:
d u c t s e lection go ty
For pro as -i -safe
.com / gb /
www.ifm
9
For industrial
applications
Standard sensors:
Safety function even if non
safety-related sensors are used.
The speed monitors monitor the
function of the connected sensors.
Intuitive handling:
Limited to the essential functions.
Easy adjustment using a rotary
switch. No parameter setting tool
required.
Robust:
Can even be used at low tempe-
ratures.
Safe fun
Danger at too high speed: the safe
speed monitor monitors the carousel
for exceeded maximum rotational
speed. EN12814 “Fairground and
amusement park machinery and
structures”.
10
Safe speed monitoring
Inductive
On the other hand, fast rotating machines
cause a high kinetic energy so that the
machines can burst if they rotate too fast.
In this case, safe speed monitors guarantee
that the machine is switched off.
Light curtains
Sometimes there is a potential risk if the
Light grids
machine is not running as fast as it should.
In this case speed monitors give a warning
if the speed is below the set minimum
speed.
Safety at Work
AS-Interface
monitoring
Safety on machine tools Speed
SmartPLC
Warning if the speed is below the set
minimum speed: the speed monitor Safe speed
monitor
monitors the “safe reduced speed” on Exceeded
the spindle to EN 61800-5-2. minimum speed,
setting range
0.5...990 Hz
ecomatmobile
Type DU110S
For produ
www.ifm ct selection go to:
.com / gb /
Introduction
safetyrela
y
Safety
11
For industrial
applications
Double:
Fail-safe PLC and standard PLC
in one housing.
Versatile:
Can be used for different func-
tions and apps.
Productive:
High machine uptime due to
sophisticated diagnostics.
Connective:
Supports numerous bus systems.
Outputs:
Eight safe local inputs and four
safe local outputs.
Clear:
Status display for safe I/Os. Error
memory with time stamp for up
to 2,000 messages.
For produ
c
Programming
www.ifm t selection go to:
Programming is done via CODESYS V3. .com / gb /
as -i -safe
The PLC has access to all interfaces of ty
the system such as comfortable diagnos-
tic functions and error memory with
time stamp for up to 2,000 messages.
Complex tasks
Control of a palletiser: the required
technology is very complex since ope-
ration is fully automatic. The SmartPLC
from ifm allows processing of safe and
non-safe signals at the same time.
12
Safety control systems
for industrial applications
Fail-safe PLC and standard PLC in one
housing. Much additional information
included.
The new SmartPLC combines two separate
PLCs in one compact housing.
While the one PLC solves safety-related
applications, the second PLC either works
as a standard PLC or as platform for other
Inductive
tasks.
Both PLCs communicate with each other,
Standard application
so that entire plant controls can be im-
plemented including safety functions and
visualisations with one only smart PLC.
Light curtains
Light grids
Fail-safe PLC
Standard PLC
Safe application
Safety at Work
AS-Interface
monitoring
Speed
Data logger
AS-i
gateway SmartPLC
ifm system
solutions
platform
ecomatmobile
Protocol
converter
Visualisation
AS-i Profinet gateway
with safe preprocessing system
Type AC422S
13
Systems for
mobile machines
Multi-level safety:
Depending on the severity of the
fault the complete installation or
only part of it can be put into the
safe state.
Can be configured
individually:
The behaviour of every single
input / output in case of a fault
can be configured.
Fast:
The fast bootup and a short error
detection time provide sufficient
safety in the application.
Powerful:
32-bit technology even for
complex control tasks.
Reduced wiring
The monitoring and processing of
safety-related sensor and actuator
signals could not be implemented in SafetyController
one individual safe control module. 80 multifunctional
CANopen Safety prevents complex inputs / outputs
additional wiring for further external
safety components.
Type CR7132
14
Safety control systems
for mobile machines
A sophisticated safety concept
For safety-relevant applications with
complex and demanding control functions
ifm provides the powerful 32-bit Safety
Controller. It has been developed accord-
ing to current safety standards.
Hardware and software have been certified
by the German TÜV association.
Inductive
What is special is the programmable,
SafetyController
layered error handling (keep alive):
The SafetyController can be used so that
if there is a serious fault it brings the plant ClassicController
into safe state before shutting down. In
E-STOP
case of less serious faults, however, parts
Light curtains
Light grids
of the machine can still be operated in
previously defined areas, not all compo-
nents have to be switched off.
The behaviour of the inputs and outputs
can be adapted to the application easily SafetyController
and precisely using the CODESYS pro-
Fail-safe sensors
Safety at Work
AS-Interface
gramming software.
Dialogue module
monitoring
Speed
Safe control of road / rail vehicles
One important requirement is the safe
re-railing of the vehicle. In addition
to the processing of the sensor and SafetyController
actuator signals the control module 32 multifunctional
also directly processes the e-stop inputs / outputs
function. A separate e-stop relay is SmartPLC
not required.
Type CR7032
ecomatmobile
15
Availability,
reliability Safety and
availability
Safety,
risk
16
Right assessment and consistent implementation
Risk analysis
Inductive
Step 2 Step 3 Step 4
Light curtains
will lead to harm. to be assessed: that a sub-function is too dangerous,
Light grids
The designer has to divide the total func- • Extent of injury (light, serious, lethal) measures how to minimise the risk have
tion of the machine into sub-functions to be defined.
• Probability of occurrence depending on:
and assess the risk of every individual
- number of people concerned
sub-function as follows:
- frequency of the event
• Which risks do the individual sub-
functions have - means of escape of the people
concerned
• Assess the environmental conditions
Safety at Work
- possibility of prevention or limitation
AS-Interface
and the conditions of use of the
sub-functions
Which events can cause a damage?
monitoring
Speed
Risk assessment to EN 13849
P2
Frequency and / or S1 b
impossible 5 exposure to a hazard P1
possible 3 F starting point for
F2
P2
likely 1 seldom to less often and / or the assessment of c
F1 the risk reduction P1
the exposure time is short
F1
+P frequent to continuous and / or P2
F2 S2 d
the exposure time is long
ecomatmobile
(PL r)
P1
11-13 14-15 F2
Possibility of avoiding P2 e
SIL3 SIL3 the hazard or limiting the harm
SIL2 SIL3 P
SIL1 SIL2 possible under specific circumstances P1
SIL1 scarcely possible P2
Introduction
Safety
17
Safety and
availability
18
Right assessment and consistent implementation
Inductive
Step 7 Step 8 Step 9
Light curtains
reached or the safety integrity level (SIL) the theoretically defined measures for risk
Light grids
reached from the characteristic values minimisation have really been implement-
according to the standard used. ed.
Does the safety level reached correspond In general, this is made by practical tests
to the value defined in the risk analysis? on the machine:
Characteristics Safety integrity PL ≥ PLr • Are the safety-related output signals
of the safety SIL ≥ SILr generated correctly?
system • Does the behaviour in case of a fault
Safety at Work
AS-Interface
Sub-system 1 correspond to the circuit category?
(detect) • Simulation of all dangerous faults.
PL d • Are the dimensions of the production
SIL 2 equipment sufficient?
PFHD = 10 -8 /h
Smallest PL / SIL
of the sub-
systems Pl d, SIL 2
monitoring
PFHD = 2,1 10 -8 /h
Speed
PL e
SIL 3
PFHD = 10 -9 /h
Sub-system 3 SIL to be
(switch) reached:
SIL 2 / PL d
PL d SmartPLC
SIL 2
PFHD = 10 -8 /h
ecomatmobile
Introduction
Safety
19
Visit our website:
www.ifm.com
Overview
ifm product range:
Industrial imaging
ifm article no. 78001842 · We reserve the right to make technical alterations without prior notice. · Printed in Germany on non-chlorine bleached paper. 03/16
Safety technology
Process sensors
Industrial
communication
Identification systems
Condition monitoring
systems
Systems for
mobile machines
Connection
technology
Accessories