Вы находитесь на странице: 1из 16

Structure

Inspection
Report
STRIN: 700707C
Structure Name:
Division:

Dive Culvert - 70 Sandy Creek W (Murray)

Western

Section: Albion
Inspection Completion Date: 05/03/2013

General Condition Rating:


There are no addendums to this report.

STRIN: 700707C

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Structure Name: Dive Culvert - 70 Sandy Creek W


(Murray)

Inspection Type: Biennial, Above Water


Approval Status: Approved
Completed Date: 5/3/2013
General Condition Rating: 5

Work Urgency Index: 6

Inspection Performed By: Clark Patterson Lee


Team Leader: Harry A Watkins P.E.

PE Number: 071693

Assistant Team Leader: Todd Day

Other/Speciality:

Sub Consultant:

Summary Remarks:
The dive culvert exhibits very moderate to heavy deterioration at the inlet and minor deterioration at the outlet
structures. There is a large accumulation of rock, branches and debris at the inlet.
Notes For Next Inspector:
This Dive Culvert is located west of the Hulberton Road Bridge between the bridge and the park.
Activity Log
Date

Arrival
Time

5/2/2013

1:00 PM 1:30 PM

5/3/2013

11:00
AM

Depart
Time

Low
High
Temp (F) Temp (F)

11:30
AM

Weather

Access

72

Clear

Walking;

68

Clear

Walking;

Remarks

Inspection Approvals
Approver

PE Number

Approval Type

Approval_Date

klotz

Headquarters Approval

11/13/2014

martindj

Division Approval

1/24/2014

smullen

Consultant Quality Control 1/24/2014

watkinsh

Inspection Complete

1/16/2014

Necessary Repairs
(Necessary Repairs identified in this inspection.)
Rating

Category

Code

Quan- WUI Remarks


tity

.303 Obstructions (1)

Miscellaneous
Elements

other miscellaneous
(describe)

Clear the rock, branches and


debris from the trash rack.
(EA).

Structure Flags
(Structure flags not resolved at the time of inspection completion.)
Page 2 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Flag Date:

Notes:

Level:

Status:

Inspection Completion Date: 05/03/2013

<No Flags>
Structure Issues
(Structure issues not resolved at the time of inspection completion.)
Issue Date:

Description:
<No Issues>

Page 3 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Inspection Ratings
Section

Page 4 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report


.100

STRIN: 700707C

Culverts - Structural (1)

Inspection Completion Date: 05/03/2013

Rating: 5

Notes: (none)

.101

Inlet (1)

Rating: 4

Notes: Previously Rated 4 The inlet structure exhibits moderate to heavy deterioration. The worst conditions are
found at the east and west wingwalls where the top and free end surfaces are moderately to heavily spalled. The
spalling extends for approximately 2/3s of the wingwall length and reaches 6 deep. The concrete within the spalls
crumbles easily when struck with a hammer. The vertical surfaces on both wingwalls exhibits mapcracking affecting
100% of their surface areas with moderate efflorescence leakage. Additionally, just above the culvert opening, the
west wingwall has a horizontal crack with profuse leakage exuding near the junction with the headwall.
The headwall exhibits small areas of honeycombing and spalling. The majority of the headwalls vertical surface is
affect by mapcracking with moderate efflorescence.
See Photograph No's. 1, 2 & 3.
.102

Outlet (1)

Rating: 6

Notes: Previously Rated 6 The outlet is in very good condition with only minor deterioration. The rating remains 6.
See Photograph No. 4.
.103

Pipe, Box, Culvert, or Arch (1)

Rating: 0

Notes: Previously Rated 0 No portion of the culvert pipe(s) is visible for inspection. The rating remains 0.
See Photograph No. 5.
.300

Flowage (1)

Rating: 4

Notes: (none)

Aqueducts (0)

Rating: 0

Notes: (none)

.301

Obstructions (1)

Rating: 0

Notes: (none)

.302A Watertight Integrity (Upper) (1)

Rating: 0

Notes: (none)

.302B Watertight Integrity (Lower) (1)

Rating: 0

Notes: (none)

Culverts (0)

Rating: 0

Notes: (none)

Page 5 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report


.303

STRIN: 700707C

Obstructions (1)

Inspection Completion Date: 05/03/2013

Rating: 4

Notes: Previously Rated 5 The trash rack is partially blocked by a large accumulation of rock, branches and debris.
The accumulation does not appear to impede the function of the dive culvert since there is no defined upstream
channel or ditch. The rating has been lowered to 4.
See Photograph No. 6.
.304

Watertight Integrity (1)

Rating: 4

Notes: Previously Rated 4 The inlet structure has an area of seepage just above the top of the culvert opening on
its headwall and west wingwall. The leakage is profuse at the junction of the two walls. There is no relative distress
found in the embankment adjacent to the structure.
The embankment adjacent to the northwest corner of the structure was observed to be only slightly moist during this
inspection.
The rating will remain 4.
See Photograph No. 3.
Ditches (0)

Rating: 0

Notes: (none)

.305

Obstructions (1)

Rating: 0

Notes: (none)

.306

Erosion (1)

Rating: 0

Notes: (none)

.400

Trash Racks (1)

Rating: 5

Notes: Previously Rated 5 The trash rack is good condition and well anchored to the concrete wingwalls. The rating
remains 5.
See Photograph No. 7.

Page 6 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Inspection Images
Section
Sketches, drawings, and photographs relevant to
the structure in general.

Page 7 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Location Map
Page 8 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Photo Location Plan

Page 9 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

G1 Inlet Structure.

Page 10 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

G2 Outlet Structure.

Page 11 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Ratings Photograph
Section
Photographs specific to inspection ratings.

Page 12 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Photo Number: 1
Description:
The inlet structure exhibits
moderate to heavy spalling but
continues to function as designed.
Location:
Inlet Structure.
Rating References:
.101 Inlet (1) - Rated 4

Photo Number: 2
Description:
The inlet structure exhibits
moderate to heavy spalling along
the wingwalls top and free
surfaces.
Location:
Inlet Structure.
Rating References:
.101 Inlet (1) - Rated 4

Page 13 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Photo Number: 3
Description:
The inlet structure exhibits
moderate to heavy spalling along
the wingwalls top and free surfaces
with profuse seepage along a
horizontal crack.
Location:
Inlet Structure.
Rating References:
.101 Inlet (1) - Rated 4
.304 Watertight Integrity (1) Rated 4

Photo Number: 4
Description:
The outlet structure is in good
condition.
Location:
Outlet structure.
Rating References:
.102 Outlet (1) - Rated 6

Page 14 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Photo Number: 5
Description:
No portion of the culvert pipe(s) is
visible for inspection.
Location:
Top of the culvert opening at the
inlet structure.
Rating References:
.103 Pipe, Box, Culvert, or Arch (1)
- Rated 0

Photo Number: 6
Description:
The trash rack is partially blocked
by a large accumulation of rock,
branches and debris that does not
appear to impede the function of
the dive culvert.
Location:
Inlet structure.
Rating References:
.303 Obstructions (1) - Rated 4

Page 15 of 16

New York State Canal Corporation

Report Created 11/13/2014 11:50:38 AM

Structure Inspection Report

STRIN: 700707C

Inspection Completion Date: 05/03/2013

Photo Number: 7
Description:
The trash rack is good condition
and well anchored to the concrete
wingwalls.
Location:
Trash rack at the inlet structure.
Rating References:
.400 Trash Racks (1) - Rated 5

Page 16 of 16